OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Data
Transcription
OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Data
www.osram-os.com OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Dr. Daniele Brunazzo | 15.12.2015 | Regensburg Light is OSRAM OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Page 1. OSRAM Biomon Sensors 03 2. TI AFE 44040 EVM Overview 04 3. Getting started 05 4. Measurement tutorial 07 5. Data Analysis 08 6. Disclaimer 12 2 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM OSRAM Biomon Sensors • Applications http://www.osram-os.com/osram_os/en/applications/areas-of-competence/health-monitoringand-fitness-tracking/index.jsp • Products http://www.osram-os.com/osram_os/en/products/product-catalog/infrared-emitters%2cdetectors-andsensors/optical-sensors/health-monitoring-sensors/index.jsp • SFH 7050 Application Note http://www.osramos.com/Graphics/XPic9/00194555_0.pdf/BioMon%20Sensor%20SFH%207050.pdf OSRAM current Health Monitoring Sensors 3 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM TI AFE 44040 EVM Overview SFH 7050 (Included in AFE 4404 EVM) Important To use the SFH 7050 the resistors on the board have to be resoldered, please see the AFE 4404 EVM User Guide TI AFE 4404 Evaluation kit • • 4 The heart rate can be easily measured with the TI AFE 4404 EVM and OSRAM health tracking sensors TI AFE 4404 EVM information available on http://www.ti.com 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 SFH 7051 (Available from OSRAM) SFH 7060 (Available from OSRAM Available components on PCB OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Getting started Installation of the TI AFE 4404 EVM software • Download the most recent version of the software on http://www.ti.com/product/AFE4404/description • Install the software and the USB drivers following the instruction on the development guide http://www.ti.com/product/AFE4404/technicaldocuments • Setting a starting configuration file: • In your installation path go to the following directory: <Installation path>\Config Files • Open the file High Level Config.ini with a text editor • Create a backup file of High Level Config.ini (e.g., High Level Config_bckp.ini) • Delete the instruction located beneath the [TX_STAGE] string in the original High Level Config.ini • Save the modified file and launch the AFE 44040EVM GUI after connecting the board (see next slide) 5 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Getting started - connections • Connect the AFE 4404 EVM to your computer through the USB cable Pin 1 connection • Connect the AFE 4404 Sensor Board to the AFE 4404 EVM using the connector supplied in the kit • When connecting the boards, be sure that the white patch on the connector is always positioned close to PIN 1. PIN 1 can easily be recognized because of its square shape (see figure) Connections 6 • Check that the green LED are on to confirm that everything has been connected properly – OSRAM Sensor Boards have no marked PIN 1, therefore a practical check is needed 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Measurement tutorial • After starting the AFE 4404 EVM GUI make sure that the board is connected to your PC and communicating properly by checking the indicator situated at the bottom right of the GUI. The indicator should be green and displaying the “HW connected” message AFE 4404 EVM GUI 7 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Measurement tutorial 1. 2. 3. 4. Go to the ADC Capture & Analysis tab Select Single Plot Mode from the menu to visualize only the data relative to LED 1 Position the Sensor Board on your wrist as shown in the picture below Start the measurement y clicking on the Capture button 1. 2. 3. 4. Sensor Board positioned on the wrist 8 AFE 4404 EVM GUI 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Measurement tutorial LED 1 reading in the time domain 9 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Measurement tutorial For a quick estimation of the heart rate: 1. Right click on the cross button on the bottom right of the graph 2. Uncheck the “Ignore Time Stamp” option to visualize the time scale in the graph 3. Select a short time period (e.g., 4 s) 4. Evaluate the heart beat looking at the period of the waveform 10 [ ]= 60[ [ ] ] 3. T = 1 sec 1. Detail of LED 1 reading in the time domain 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 OSRAM Biomon Sensors evaluation board TI AFE 4404 EVM Data Analysis • Data recorded through the AFE 4404 EVM can be saved and analyzed offline with different software (e.g., MS Excel, Matlab, etc.) Export Data 11 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015 Disclaimer PLEASE CAREFULLY READ THE BELOW TERMS AND CONDITIONS BEFORE USING THE HEREIN AGREE THESE TERMS AND INFORMATION SHOWN HEREIN. IF YOU DO NOT WITH ANY OF CONDITIONS, DO NOT USE THE INFORMATION. The information shown in this document is provided by OSRAM Opto Semiconductors GmbH on an “as is basis” and without OSRAM Opto Semiconductors GmbH assuming, express or implied, any warranty or liability whatsoever, including, but not limited to the warranties of correctness, completeness, merchantability, fitness for a particular purpose, title or non-infringement of rights. In no event shall OSRAM Opto Semiconductors GmbH be liable – regardless of the legal theory – for any direct, indirect, special, incidental, exemplary, consequential, or punitive damages related to the use of the information. This limitation shall apply even if OSRAM Opto Semiconductors GmbH has been advised of possible damages. As some jurisdictions do not allow the exclusion of certain warranties or limitations of liability, the above limitations or exclusions might not apply. The liability of OSRAM Opto Semiconductors GmbH would in such case be limited to the greatest extent permitted by law. OSRAM Opto Semiconductors GmbH may charge the information shown herein at anytime without notice to users and is not obligated to provide any maintenance (including updates or notifications upon changes) or support related to the information. Any rights not expressly granted herein are reserved. Except for the right to use the information shown herein, no other rights are granted nor shall any obligation be implied requiring the grant of further rights. Any and all rights or licenses for or regarding patents or patent applications are expressly excluded. 12 2015-12-15_OSRAM Biomon sensors evaluation board | OS IR AE CA | DB 12/15/2015