1) - COMPRESSOR COOLING TYPE

Transcription

1) - COMPRESSOR COOLING TYPE
R-600a - R-134a - Blends - R-290
1) - COMPRESSOR COOLING TYPE
Blends
Condensing pressure must not exceed 14.5 kgf/cm2 (206 psig)
when in continuous operation at maximum expected ambient
temperature (43oC) and the peak condensing temperature
must not exceed 18.2 kgf/cm2 gauge (259 psig).
1.1) - Static Cooling (S)
The compressor does not require fan cooling and must
be installed in such as way so as to allow cooling through
ambient air, thus, preventing over heating.
R-134a
Condensing pressure must not exceed 16.1 kgf/cm2 (229 psig)
when in continuous operation at maximum expected ambient
temperature (43oC) and the peak condensing temperature must
not exceed 20.53 kgf/cm2 gauge (292 psig).
1.2) - Fan Cooling (F)
The compressor requires a minimum air flow of 3 m/s for its
cooling. Flows of lesser values must be evaluated through
laboratory tests.
2.4) - Evaporating Temperature Range
1.3) - Oil Cooling (OC)
The compressor uses an internal coil immersed in oils and
connected to the hermetic system to help with compressor
cooling. The use of more efficient compressors can
eliminate the need for oil cooling.
2) - OPERATING CONDITIONS
APPLICATION
TEMPERATURE RANGE
LBP
-35ºC to -10ºC
( -31ºF to +14ºF )
L/MBP
-35ºC to -5ºC
( -31ºF to +23ºF )
M/HBP
-10ºC to +15ºC
( 14ºF to +59ºF )
HBP
-5ºC to +15ºC
( 23ºF to +59ºF )
L/M/HBP
-35ºC to +15ºC
( -31ºF to +59ºF )
2.1) - Starting and Operating Voltage
The compressors start at 90% of the nominal voltage
• Equalized pressures of up to 4 kgf/cm2 manometric gauge
(58 psig) (R-600a).
• Equalized pressures of up to 5 kgf/cm² manometric gauge
(71 psig) (Blends).
• Equalized pressures of up to 6 kgf/cm² manometric gauge
(85 psig) (R-134a).
3) - MOTOR
• Equalized pressures of up to 9 kgf/cm² manometric gauge
(128 psig) (R-290).
The compressors in the performance table are equipped with
monophase, induction motors.
Depending on the working condition and system
characteristics, the compressor can operate at even lower
voltages, see perfomance table.
3.1) - Motor Torque
The compressor motors are denominated:
2.2) - Winding Temperature
LST - Low Starting Torque used in systems with capillary tube
The winding temperature should not exceed 130 C (266 F)
when in continuous operation. For the winding temperature
evaluation we recommend the “Ohmic Resistance
Measurement Method”.
(According to Application Manual Embraco).
o
o
HST - High Starting Torque used in systems with expansion valve
or with capillary tube
3.2) - Types of Electric Motors
2.3) - Condensing Pressure Limit
RSIR (PTCSIR) - Resistive Start - Inductive Run
Does not use capacitors
The compressors must operate in accordance with that
described below:
CSIR - Capacitive Start - Inductive Run
Uses electrolytic capacitor (starting)
R-600a
RSCR (PTCSCR) - Resistive Start - Capacitive Run
Uses permanent capacitor (running)
Condensing pressure must not exceed 7.7 kgf/cm2
(113 psig) when in continuous operation at maximum
expected ambient temperature (43oC) and the peak
condensing temperature must not exceed 9.8 kgf/cm2 gauge
(145 psig).
CSR (CSCR) - Capacitive Start & Run
Uses electrolytic (starting) and permanent capacitor
at the same time – used with 4 terminal PTC
2
9) - PERFORMANCE TABLES
R-134a -
L/MBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
EM 20HHR
115-127V 60Hz
L/M/HBP
2.27
98 - 140
S/F
ISO22
221
2.00
EM 20HHR
220-240V 50-60Hz
L/M/HBP
2.27
187 - 242
S/F
ISO22
216
1.96
EMI 28HER
115-127V 60Hz
LBP
3.00
98 - 140
S
ISO10
61
0.92
EMI 28HER
220-240V 50-60Hz
LBP
3.00
198 - 242
S
ISO10
61
0.92
EMI 30HER
115-127V 60Hz
LBP
3.00
98 - 140
S
ISO10
66
0.95
EMI 30HER
220-240V 50-60Hz
LBP
3.00
98 - 140
S
ISO10
66
0.95
EM 30HHR
115V 60Hz
L/M/HBP
3.00
97 - 135
S/F
ISO22
301
1.98
EM 30HHR
220-240V 50-60Hz
L/M/HBP
3.00
187 - 242
S/F
ISO22
299
2.00
EMT 30HSC
115V 60Hz
LBP
3.00
103 - 135
S
ISO10
67
1.00
EMU 30HSC
115V 60Hz
LBP
3.00
103 - 135
S
ISO10
71
1.08
EMU 30HER
115-127V 60Hz
LBP
3.00
98 - 140
S
ISO10
75
1.06
EMU 30HER
220-240V 50-60Hz
LBP
3.00
187 - 242
S
ISO10
75
1.06
EMI 40HNR
115-127V 60Hz
LBP
3.77
98 - 140
S
ISO10
81
0.96
EMI 40HNR
220V 50-60Hz
LBP
3.77
187 - 242
S
ISO10
81
0.96
EM 45HHR
115-127V 60Hz
L/M/HBP
3.77
98 - 140
S/F
ISO22
299
2.00
EM 45HNR
220V 50-60Hz
LBP
3.77
98 - 140
S
ISO10
91
0.93
EMI 45HER
220-240V 50-60Hz
LBP
3.77
191 - 242
S
ISO10
91
1.04
EMI 45HER
115-127V 60Hz
LBP
4.08
103 - 135
S
ISO10
94
1.00
EMU 45HEP
100V 50-60Hz
LBP
3.77
85 - 110
S
ISO10
95
1.04
EMU 45HSC
220-240V 50-60Hz
LBP
3.77
187 - 242
S
ISO10
97
1.14
EMU 45HER
115-127V 60Hz
LBP
3.77
98 - 140
S
ISO10
98
1.07
EMU 45HER
220-240V 50-60Hz
LBP
3.77
191 - 242
S
ISO10
98
1.08
EMU 45HSC
115-127V 60Hz
LBP
3.77
98 - 140
S
ISO10
98
1.15
EMY 45HER
115-127V 60Hz
LBP
3.77
103 - 140
S
ISO10
98
1.12
EMY 45HSC
115-127V 60Hz
LBP
3.77
103 - 140
S
ISO10
98
1.22
EM 55HNR
115-127V 60Hz
LBP
4.60
103 - 135
S
ISO22
110
0.94
EM 55HNR
220V 50-60Hz
LBP
4.60
103 - 135
S/F
ISO22
110
0.94
EMI 55HER
115-127V 60Hz
LBP
4.60
98 - 140
S/F
ISO22
110
1.03
EMI 55HER
220V 50-60Hz
LBP
4.60
198 - 242
S/F
ISO22
110
1.03
EMI 60HER
115-127V 60Hz
LBP
4.99
98 - 135
S
ISO10
124
0.99
EMI 60HER
220V 50-60Hz
LBP
4.99
98 - 135
S
ISO10
124
0.99
EMU 60HEP
100V 50-60Hz
LBP
4.99
85 - 110
S
ISO10
128
1.09
EMU 60HSC
115-127V 60Hz
LBP
4.99
103 - 140
S
ISO10
128
1.15
EMY 60HER
115-127V 60Hz
LBP
4.99
103 - 140
S
ISO10
132
1.17
EMY 60HSC
115-127V 60Hz
LBP
4.99
103 - 140
S
ISO10
132
1.23
EMZ 60HSC
115-127V 60Hz
LBP
4.99
98 - 140
S
ISO10
132
1.30
EGYS 60HLP
115-127V 60Hz
LBP
5.09
98 - 140
S
ISO10
132
1.28
EGZS 60HLP
115-127V 60Hz
LBP
5.09
98 - 140
S
ISO10
132
1.39
EGX 60HLC
115-127V 60Hz
LBP
5.09
98 - 140
S
ISO10
132
1.41
EM 65HHC
115V 60Hz
L/M/HBP
5.54
103 - 135
S/F
ISO22
564
2.18
EM 65HNR
115-127V 60Hz
L/MBP
5.54
103 - 140
F
ISO10
141
0.91
FFI 6HAK
220V 50-60Hz
L/MBP
6.23
98 - 135
S
ISO22
147
0.99
FFV 6HAK
115-127V 60Hz
LBP
6.23
98 - 140
S
ISO10
147
1.12
FFV 6HAK
220V 50-60Hz
LBP
6.23
187 - 242
S
ISO10
147
1.12
EMY 70HER
115-127V 60Hz
LBP
5.72
98 - 140
S
ISO10
147
1.11
EMY 70HER
220V 60Hz
LBP
5.72
187 - 242
S
ISO10
147
1.11
EMY 70HSC
115-127V 60Hz
LBP
5.72
103 - 140
S
ISO10
147
1.22
FFI 6HAK
115-127V 60Hz
L/MBP
6.23
98 - 135
S
ISO22
147
0.99
EMX 70HSC
115-127V 60Hz
LBP
5.96
98 - 140
S
ISO10
150
1.33
FF 7.5HBK
115V 60Hz
L/M/HBP
6.92
103 - 135
S
ISO22
547
1.84
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
4
R-134a -
L/MBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
COOLING
TYPE*
CHECK POINT DATA
CECOMAF (CALCULATED)
OIL VISCOSITY
CAPACITY
W
COP
W/W
EGAS 70HLR
115-127V 60Hz
LBP
5.56
98 - 140
S
ISO10
151
1.25
EGAS 70HLR
220-240V 50-60Hz
LBP
5.56
198 - 255
S
ISO10
151
1.25
EGUS 70HLP
115-127V 60Hz
LBP
5.56
98 - 140
S
ISO10
151
1.29
EGYS 70HLP
115-127V 60Hz
LBP
5.56
98 - 140
S
ISO10
151
1.31
EGZS 70HLC
220-240V 50-60Hz
LBP
5.56
198 - 255
S
ISO7
151
1.43
EGZS 70HLP
115-127V 60Hz
LBP
5.56
98 - 140
S
ISO10
151
1.41
EGX 70HLC
115-127V 60Hz
LBP
5.56
98 - 140
S
ISO10
151
1.44
FGI 85HAK
115-127V 60Hz
LBP
7.15
93 - 121
S
ISO22
152
0.98
1.06
EMI 70HER
220V 60Hz
LBP
5.89
187 - 242
S/F
ISO10
153
EMI 70HNR
115V 60Hz
L/MBP
5.89
103 - 127
S/F
ISO10
153
0.97
FGS 70HA
115-127V 60Hz
LBP
6.36
103 - 140
S
ISO10
153
1.20
1.20
FGS 70HA
220-240V 50-60Hz
LBP
6.36
198 - 242
S
ISO10
154
FF 8.5HBK
115V 60Hz
L/M/HBP
7.95
103 - 135
S/F
ISO22
681
1.79
FF 8.5HBK
220V 60Hz
L/M/HBP
7.95
198 - 242
S/F
ISO22
681
1.77
FFU 70HAK
115-127V 60Hz
L/MBP
6.36
98 - 140
S/F
ISO10
163
1.18
FFU 70HAK
220-240V 50-60Hz
L/MBP
6.36
98 - 140
S/F
ISO10
163
1.18
FGU 70HA
115-127V 60Hz
LBP
6.36
98 - 140
S
ISO10
163
1.26
FFI 7.5HAK
115V 60Hz
L/MBP
6.76
98 - 135
S
ISO10
166
1.08
FFV 7.5HAK
115-127V 60Hz
L/MBP
6.76
98 - 140
S
ISO10
166
1.16
FFV 7.5HAK
220-240V 50-60Hz
L/MBP
6.76
187 - 242
S
ISO10
166
1.16
FFI 7.5HAK
220-240V 50-60Hz
L/MBP
6.76
187 - 242
S
ISO10
167
1.09
FFU 80HAK
115-127V 60Hz
L/MBP
6.76
98 - 140
S/F
ISO10
177
1.18
FFU 80HAK
220-240V 50-60Hz
L/MBP
6.76
187 - 242
S/F
ISO10
177
1.18
FGU 80HA
115-127V 60Hz
LBP
6.76
98 - 140
S
ISO10
177
1.27
FGU 80HA
220-240V 50-60Hz
LBP
6.76
187 - 242
S
ISO10
177
1.27
EGAS 80HLR
115-127V 60Hz
LBP
6.36
98 - 140
S
ISO10
178
1.22
EGAS 80HLR
220-240V 50-60Hz
LBP
6.36
198 - 242
S
ISO10
178
1.27
EGUS 80HLP
115-127V 60Hz
LBP
6.36
98 - 140
S
ISO10
178
1.29
EGYS 80HLP
115-127V 60Hz
LBP
6.36
98 - 140
S
ISO10
178
1.32
EGZS 80HLC
220-240V 50-60Hz
LBP
6.36
198 - 255
S
ISO10
178
1.42
EGZS 80HLP
115-127V 60Hz
LBP
6.36
103 - 140
S
ISO10
178
1.31
EGX 80HLC
115-127V 60Hz
LBP
6.36
98 - 140
S
ISO10
178
1.45
FGS 80HA
115-127V 60Hz
LBP
7.15
103 - 140
S
ISO10
178
1.23
FGS 80HA
220-240V 50-60Hz
LBP
7.15
198 - 242
S
ISO10
179
1.23
FFI 8.5HAK
115-127V 60Hz
L/MBP
7.15
98 - 135
S
ISO10
180
1.12
FFI 8.5HAK
220-240V 50-60Hz
L/MBP
7.15
187 - 242
S/F
ISO10
180
1.12
FFV 8.5HAK
115-127V 60Hz
L/MBP
7.15
98 - 140
S
ISO10
180
1.16
FFV 8.5HAK
220-240V 50-60Hz
L/MBP
7.15
187 - 242
S
ISO10
180
1.16
FF 10HBK
115V 60Hz
L/M/HBP
9.04
103 - 127
S/F
ISO22
766
1.77
FF 10HBK
220V 60Hz
L/M/HBP
9.04
198 - 242
S/F
ISO22
766
1.77
FGS 90HA
115-127V 60Hz
LBP
7.95
103 - 140
S
ISO10
204
1.22
FGS 90HA
220-240V 50-60Hz
LBP
7.95
198 - 242
S
ISO10
204
1.23
FGU 90HA
115-127V 60Hz
LBP
7.55
98 - 140
S
ISO10
204
1.26
EGUS 90HLP
115-127V 60Hz
LBP
7.15
103 - 140
S
ISO10
206
1.30
EGYS 90HLP
115-127V 60Hz
LBP
7.15
103 - 140
S
ISO7
206
1.33
EGZS 90HLC
220-240V 50-60Hz
LBP
7.15
198 - 255
S
ISO10
206
1.42
EGZS 90HLP
115-127V 60Hz
LBP
7.15
98 - 140
S
ISO10
206
1.41
EGX 90HLC
115-127V 60Hz
LBP
7.15
98 - 140
S
ISO10
206
1.45
FFU 100HAK
115-127V 60Hz
L/MBP
7.95
98 - 140
S
ISO10
214
1.16
FFU 100HAK
220-240V 50-60Hz
L/MBP
7.95
198 - 242
S/F
ISO10
214
1.16
FFI 10HAK
115-127V 60Hz
L/MBP
9.04
103 - 135
S
ISO22
223
1.12
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
6
R-134a -
L/MBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
FFI 10HAK
220-230V 50-60Hz
L/MBP
9.04
187 - 242
S
ISO22
223
1.12
EGZ 100HLP
115-127V 60Hz
LBP
7.95
103 - 140
S
ISO10
224
1.30
EGAS 100HLR
220-240V 50-60Hz
LBP
7.95
198 - 255
S
ISO10
228
1.26
EGZS 100HLC
220-240V 50-60Hz
LBP
7.95
198 - 255
S
ISO10
228
1.41
EGZS 100HLP
115-127V 60Hz
LBP
7.95
98 - 140
S
ISO10
228
1.38
FGS 100HA
115-127V 60Hz
LBP
9.04
103 - 135
S
ISO10
231
1.23
FGS 100HA
220-240V 50-60Hz
LBP
9.04
198 - 242
S
ISO22
231
1.22
FFI 12HBX
115-127V 60Hz
L/M/HBP
11.14
103 - 135
F
ISO22
1149
2.01
1.80
FFI 12HBX
220V 60Hz
L/M/HBP
11.14
198 - 242
S/F
ISO22
1149
FFU 130HAX
115-127V 60Hz
L/MBP
10.61
98 - 140
F
ISO10
271
1.11
FFU 130HAX
220V 60Hz
L/MBP
10.61
198 - 242
F
ISO10
271
1.09
Note: Condensing Temperature 54.4ºC (129.92ºF)
R-134a -
*Static Cooling (S) / Fan Cooling (F)
M/HBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
COOLING
TYPE*
CHECK POINT DATA
CECOMAF (CALCULATED)
OIL VISCOSITY
CAPACITY
W
COP
W/W
EM 20HHR
220-240V 50-60Hz
L/M/HBP
2.27
187 - 242
S/F
ISO22
216
1.96
EM 20HHR
115-127V 60Hz
L/M/HBP
2.27
98 - 140
S/F
ISO22
221
2.00
EM 30HHR
220-240V 50-60Hz
L/M/HBP
3.00
187 - 242
S/F
ISO22
299
2.00
EM 30HHR
115V 60Hz
L/M/HBP
3.00
97 - 135
S/F
ISO22
301
1.98
EM 45HHR
115-127V 60Hz
L/M/HBP
3.77
98 - 140
S/F
ISO22
299
2.00
EM 55HHR
115V 60Hz
HBP
4.60
98 - 135
F
ISO22
466
1.99
EM 55HHR
220-240V 50-60Hz
HBP
4.60
198 - 242
F
ISO22
466
2.05
EM 65HHC
115V 60Hz
L/M/HBP
5.54
103 - 135
S/F
ISO22
564
2.18
EM 65HHR
115V 60Hz
M/HBP
5.54
103 - 135
F
ISO22
564
1.98
EM 65HHR
220V 50-60Hz
M/HBP
5.54
103 - 135
F
ISO22
567
1.97
FF 7.5HBK
115V 60Hz
L/M/HBP
6.92
103 - 135
S
ISO22
547
1.84
FF 8.5HBK
115V 60Hz
L/M/HBP
7.95
103 - 135
S/F
ISO22
681
1.79
FF 8.5HBK
220V 60Hz
L/M/HBP
7.95
198 - 242
S/F
ISO22
681
1.77
FF 10HBK
115V 60Hz
L/M/HBP
9.04
103 - 127
S/F
ISO22
766
1.77
1.77
FF 10HBK
220V 60Hz
L/M/HBP
9.04
198 - 242
S/F
ISO22
766
FFI 12HBX
115-127V 60Hz
L/M/HBP
11.14
103 - 135
F
ISO22
1149
2.01
FFI 12HBX
220V 60Hz
L/M/HBP
11.14
198 - 242
S/F
ISO22
1149
1.80
Note: Condensing Temperature 54.4ºC (129.92ºF)
R-600a -
*Static Cooling (S) / Fan Cooling (F)
L/MBP - 60Hz
MODEL
EMT 35CLP
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
4.50
85 - 110
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
S
ISO7
CAPACITY
W
COP
W/W
72
1.11
100V 50-60Hz
LBP
EMU 45CLP
100V 50-60Hz
LBP
5.96
85 - 110
S
ISO10
91
1.14
EGS 75CLP
115-127V 60Hz
LBP
10.08
98 - 140
S
ISO7
164
1.24
EGS 75CLP
220-240V 50-60Hz
LBP
10.08
187 - 242
S
ISO7
164
1.24
EGS 80CLP
115-127V 60Hz
L/MBP
11.14
98 - 140
S
ISO10
187
1.22
EGS 80CLP
220-240V 50-60Hz
L/MBP
11.14
187 - 242
S
ISO10
187
1.22
EGS 90CLP
220-240V 50-60Hz
LBP
12.21
187 - 242
S
ISO7
201
1.22
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
8
Blends -
L/MBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
EM 20BR
115V 60Hz
L/M/HBP
2.27
98 - 135
S/F
ISO32
208
1.89
EM 20BR
220V 60Hz
L/M/HBP
2.27
187 - 242
S/F
ISO32
208
1.89
EM 30NR
115V 60Hz
LBP
3.00
103 - 127
S
ISO32
71
0.82
EM 30NR
220V 60Hz
LBP
3.00
198 - 242
S
ISO32
71
0.82
EM 30SC
115V 60Hz
LBP
3.00
103 - 135
S
ISO32
71
0.93
EM 40NR
115V 60Hz
LBP
3.77
103 - 127
S
ISO32
95
0.85
EM 40NR
220V 60Hz
LBP
3.77
198 - 242
S
ISO32
95
0.85
EMI 55ER
220-240V 50-60Hz
LBP
4.60
198 - 242
S/F
ISO32
129
1.03
EM 55NR
115V 60Hz
LBP
4.99
103 - 135
S
ISO32
132
0.93
EM 55NR
220V 60Hz
LBP
4.99
198 - 242
S
ISO32
132
0.93
EM 65NR
115V 60Hz
LBP
5.54
103 - 132
S
ISO32
143
0.96
EM 65NR
220V 60Hz
LBP
5.54
198 - 242
S
ISO32
143
0.93
FF 6BK
115V 60Hz
L/M/HBP
6.23
103 - 135
S
ISO32
902
1.60
FF 6BK
220V 60Hz
L/M/HBP
6.23
198 - 242
S
ISO32
902
1.60
FF 7.5BK
115-127V 60Hz
L/M/HBP
6.92
103 - 140
S
ISO32
902
1.60
FF 7.5BK
220V 60Hz
L/M/HBP
6.92
198 - 242
S
ISO32
902
1.60
EG 70LR
115V 60Hz
LBP
5.96
103 - 140
S
ISO32
167
1.00
EG 70LR
220V 60Hz
LBP
5.96
187 - 242
S
ISO32
167
1.00
FFU 70AK
115-127V 60Hz
L/MBP
6.36
98 - 140
S/F
ISO32
189
1.15
FFU 70AK
220-240V 50-60Hz
L/MBP
6.36
187 - 242
S/F
ISO32
189
1.15
FF 8.5BK
115V 60Hz
L/M/HBP
7.95
103 - 135
S/F
ISO32
695
1.64
FF 8.5BK
220V 60Hz
L/M/HBP
7.95
198 - 242
S/F
ISO32
695
1.71
FFU 100AK
220V 50-60Hz
L/MBP
7.95
198 - 242
S/F
ISO32
194
1.02
FFU 80AK
115-127V 60Hz
L/MBP
6.76
98 - 140
S/F
ISO32
206
1.15
FFU 80AK
220-240V 50-60Hz
L/MBP
6.76
187 - 242
S/F
ISO32
206
1.15
FF 10BK
115V 60Hz
L/M/HBP
9.04
103 - 135
S/F
ISO32
732
1.56
FF 10BK
220V 60Hz
L/M/HBP
9.04
198 - 242
S/F
ISO32
732
1.56
FFU 100AK
115-127V 60Hz
L/MBP
7.95
103 - 140
S/F
ISO32
237
1.11
FFU 100AK
220V 50-60Hz
L/MBP
7.95
198 - 242
S/F
ISO32
237
1.11
FF 11.5BK
115-127V 60Hz
L/M/HBP
11.14
103 - 140
F
ISO32
902
1.59
FF 11.5BK
220V 60Hz
L/M/HBP
11.14
198 - 242
S/F
ISO32
902
1.60
FFI 12BX
220V 60Hz
L/M/HBP
11.14
198 - 242
S/F
ISO32
1092
1.80
FFI 12BK
115V 60Hz
L/M/HBP
11.14
103 - 127
F
ISO32
1038
1.68
FFI 12BX
115V 60Hz
L/M/HBP
11.14
103 - 135
F
ISO32
1128
2.01
FFU 130AX
220V 60Hz
L/MBP
10.61
198 - 242
S/F
ISO32
305
1.02
FFU 130AX
115-127V 60Hz
L/MBP
10.61
98 - 140
F
ISO32
317
1.11
Note: Condensing Temperature 54.4ºC (129.92ºF)
Blends -
*Static Cooling (S) / Fan Cooling (F)
M/HBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
EM 20BR
115V 60Hz
L/M/HBP
2.27
98 - 135
S/F
ISO32
208
1.89
EM 20BR
220V 60Hz
L/M/HBP
2.27
187 - 242
S/F
ISO32
208
1.89
FF 6BK
115V 60Hz
L/M/HBP
6.23
103 - 135
S
ISO32
902
1.60
FF 6BK
220V 60Hz
L/M/HBP
6.23
198 - 242
S
ISO32
902
1.60
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
10
Blends -
M/HBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
COOLING
TYPE*
CHECK POINT DATA
CECOMAF (CALCULATED)
OIL VISCOSITY
CAPACITY
W
COP
W/W
FF 7.5BK
115-127V 60Hz
L/M/HBP
6.92
103 - 140
S
ISO32
902
1.60
FF 7.5BK
220V 60Hz
L/M/HBP
6.92
198 - 242
S
ISO32
902
1.60
FF 8.5BK
115V 60Hz
L/M/HBP
7.95
103 - 135
S/F
ISO32
695
1.64
FF 8.5BK
220V 60Hz
L/M/HBP
7.95
198 - 242
S/F
ISO32
695
1.71
FF 10BK
115V 60Hz
L/M/HBP
9.04
103 - 135
S/F
ISO32
732
1.56
FF 10BK
220V 60Hz
L/M/HBP
9.04
198 - 242
S/F
ISO32
732
1.56
FF 11.5BK
115-127V 60Hz
L/M/HBP
11.14
103 - 140
F
ISO32
902
1.59
FF 11.5BK
220V 60Hz
L/M/HBP
11.14
198 - 242
S/F
ISO32
902
1.60
FFI 12BK
115V 60Hz
L/M/HBP
11.14
103 - 127
F
ISO32
1038
1.68
FFI 12BX
220V 60Hz
L/M/HBP
11.14
198 - 242
S/F
ISO32
1092
1.80
FFI 12BX
115V 60Hz
L/M/HBP
11.14
103 - 135
F
ISO32
1128
2.01
Note: Condensing Temperature 54.4ºC (129.92ºF)
R-290 -
*Static Cooling (S) / Fan Cooling (F)
L/MBP - 60Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
COOLING
TYPE*
CHECK POINT DATA
CECOMAF (CALCULATED)
OIL VISCOSITY
CAPACITY
W
COP
W/W
EMI 90UEX
115-127V 60Hz
L/MBP
4.99
98 - 140
F
ISO32
205
1.08
FFU 130UAX
220-240V 50-60Hz
L/MBP
6.76
187 - 255
F
ISO32
295
1.22
FFU 160UAX
115-127V 60Hz
L/MBP
7.95
98 - 140
F
ISO32
362
1.22
Note: Condensing Temperature 54.4ºC (129.92ºF)
R-134a -
*Static Cooling (S) / Fan Cooling (F)
L/MBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
COOLING
TYPE*
CHECK POINT DATA
CECOMAF (CALCULATED)
OIL VISCOSITY
CAPACITY
W
COP
W/W
EM 20HHR
220-240V 50-60Hz
L/M/HBP
2.27
187 - 255
S/F
ISO22
221
2.00
EMI 28HER
220-240V 50-60Hz
LBP
3.00
198 - 255
S
ISO10
53
0.89
EMI 30HER
220-240V 50-60Hz
LBP
3.00
187 - 242
S
ISO10
53
0.89
EM 30HHR
220-240V 50-60Hz
L/M/HBP
3.00
187 - 255
S/F
ISO22
301
1.98
EMU 30HER
220-240V 50-60Hz
LBP
3.00
187 - 255
S
ISO10
60
0.98
EMI 40HNR
220V 50-60Hz
LBP
3.77
187 - 255
S
ISO10
66
0.86
EM 45HNR
220V 50-60Hz
LBP
3.77
187 - 242
S
ISO10
72
0.80
EMI 45HER
220-240V 50-60Hz
LBP
3.77
187 - 255
S
ISO10
74
0.96
EM 45HHR
220-240V 50Hz
L/M/HBP
3.77
198 - 255
S
ISO22
75
0.81
EMU 45HEP
100V 50-60Hz
LBP
3.77
85 - 110
S
ISO10
76
0.97
EMU 45HER
220-240V 50-60Hz
LBP
3.77
187 - 255
S
ISO10
79
1.02
EMY 45HSC
220-240V 50Hz
LBP
3.77
198 - 255
S
ISO10
81
1.22
EMU 45HSC
220-240V 50-60Hz
LBP
3.77
187 - 255
S
ISO10
81
1.11
EM 55HNR
220V 50-60Hz
LBP
4.60
187 - 242
S
ISO22
91
0.85
EMI 55HER
220V 50-60Hz
LBP
4.60
198 - 255
S/F
ISO22
91
0.97
EM 50HNP
220-240V 50Hz
LBP
4.99
187 - 255
S
ISO22
92
0.93
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
12
R-134a -
L/MBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
COOLING
TYPE*
CHECK POINT DATA
CECOMAF (CALCULATED)
OIL VISCOSITY
CAPACITY
W
COP
W/W
EMI 60HER
220V 50-60Hz
LBP
4.99
187 - 242
S
ISO22
102
0.90
EM 60HNP
220-240V 50Hz
LBP
5.54
198 - 255
S
ISO22
105
0.95
EMU 60HEP
100V 50-60Hz
LBP
4.99
85 - 110
S
ISO10
105
0.98
EMY 60HSC
220-240V 50Hz
LBP
4.99
198 - 255
S
ISO10
107
1.24
EM 65HNR
220V 50Hz
LBP
5.54
187 - 242
S
ISO22
112
0.92
EGAS 70HLR
220-240V 50-60Hz
LBP
5.56
198 - 255
S
ISO10
121
1.16
EGZS 70HLC
220-240V 50-60Hz
LBP
5.56
198 - 255
S
ISO7
121
1.38
FG 65HAK
220-240V 50Hz
LBP
6.76
198 - 255
S/F
ISO22
121
0.92
EMI 70HER
220V 50Hz
LBP
5.89
187 - 242
S/F
ISO22
123
0.93
1.08
FFV 6HAK
220V 50-60Hz
LBP
6.23
187 - 255
S
ISO10
124
FFI 6HAK
220V 50-60Hz
L/MBP
6.23
187 - 242
S
ISO22
126
0.91
FGS 70HA
220-240V 50-60Hz
LBP
6.36
198 - 255
S
ISO10
130
1.19
FFU 70HAK
220-240V 50-60Hz
L/MBP
6.36
187 - 255
S/F
ISO10
137
1.13
EMY 65HLC
220-240V 50Hz
LBP
5.96
187 - 255
S
ISO10
137
1.26
FFI 7.5HAK
220-240V 50-60Hz
L/MBP
6.76
187 - 255
S
ISO22
141
1.00
FFV 7.5HAK
220-240V 50-60Hz
L/MBP
6.76
187 - 255
S
ISO10
141
1.11
EG 70HLR
220-240V 50Hz
LBP
6.76
170 - 255
S
ISO22
142
1.10
FG 75HAK
220-240V 50Hz
LBP
7.95
198 - 255
S/F
ISO22
143
0.92
FF 8.5HBK
220-240V 50Hz
L/M/HBP
7.95
187 - 255
S/F
ISO22
681
1.77
EGAS 80HLR
220-240V 50-60Hz
LBP
6.36
198 - 255
S
ISO10
144
1.20
EGZS 80HLC
220-240V 50-60Hz
LBP
6.36
198 - 255
S
ISO10
144
1.38
1.22
FGU 80HA
220-240V 50-60Hz
LBP
6.76
187 - 255
S
ISO10
147
FFU 80HAK
220-240V 50-60Hz
L/MBP
6.76
187 - 255
S/F
ISO10
147
1.11
FGS 80HA
220-240V 50-60Hz
LBP
7.15
198 - 255
S
ISO10
151
1.22
1.09
EG 80HLR
220-240V 50Hz
LBP
7.15
170 - 255
S
ISO22
152
FFI 8.5HAK
220-240V 50-60Hz
L/MBP
7.15
187 - 255
S/F
ISO10
152
1.07
FFV 8.5HAK
220-240V 50-60Hz
L/MBP
7.15
187 - 255
S
ISO10
152
1.09
EGYS 90HLP
220-240V 50Hz
LBP
7.15
198 - 255
S
ISO10
167
1.32
EGZS 90HLC
220-240V 50-60Hz
LBP
7.15
198 - 255
S
ISO10
167
1.38
FG 85HAK
220-240V 50Hz
LBP
9.04
198 - 255
S/F
ISO22
168
0.95
FGS 90HA
220-240V 50-60Hz
LBP
7.95
198 - 255
S
ISO10
173
1.22
FFU 100HAK
220-240V 50-60Hz
L/MBP
7.95
198 - 255
S
ISO10
177
1.06
FGS 100HA
220-240V 50-60Hz
LBP
9.04
198 - 255
S
ISO22
184
1.11
FFI 10HAK
220-230V 50-60Hz
L/MBP
9.04
187 - 244
S
ISO22
184
1.03
EGAS 100HLR
220-240V 50-60Hz
LBP
7.95
198 - 255
S
ISO10
186
1.20
EGYS 100HLP
220-240V 50Hz
LBP
7.95
198 - 255
S
ISO10
186
1.32
EGZS 100HLC
220-240V 50-60Hz
LBP
7.95
198 - 255
S
ISO10
186
1.37
EG 100HLR
220-240V 50Hz
LBP
9.04
170 - 255
S
ISO22
191
1.11
FG 95HAK
220-240V 50Hz
LBP
10.61
198 - 255
S/F
ISO22
191
0.95
FFU 130HAX
220-240V 50Hz
L/MBP
10.61
187 - 255
F
ISO10
229
1.09
FGS 130HA
220-240V 50Hz
LBP
11.14
198 - 255
S
ISO22
235
1.18
FFI 12HBK
220-240V 50Hz
L/M/HBP
11.14
198 - 255
F
ISO22
974
2.06
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
14
R-134a -
M/HBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
EM 20HHR
220-240V 50-60Hz
L/M/HBP
2.27
187 - 255
S/F
ISO22
221
2.00
EM 30HHR
220-240V 50-60Hz
L/M/HBP
3.00
187 - 255
S/F
ISO22
301
1.98
EM 45HHR
220-240V 50Hz
L/M/HBP
3.77
198 - 255
S/F
ISO22
75
0.81
EMT 45HDR
220-240V 50Hz
L/M/HBP
3.97
187 - 255
F
ISO10
354
2.24
EM 55HHR
220-240V 50-60Hz
HBP
4.60
198 - 255
F
ISO22
394
2.13
EM 65HHR
220-240V 50Hz
HBP
5.54
198 - 255
F
ISO22
473
2.06
EM 65HHR
220V 50-60Hz
M/HBP
5.54
187 - 242
F
ISO22
477
1.89
FF 8.5HBK
220-240V 50Hz
L/M/HBP
7.95
187 - 255
S/F
ISO22
681
1.77
FFI 12HBX
220-240V 50Hz
M/HBP
11.14
198 - 255
F
ISO22
939
2.01
FFI 12HBK
220-240V 50Hz
L/M/HBP
11.14
198 - 255
F
ISO22
974
2.06
Note: Condensing Temperature 54.4ºC (129.92ºF)
R-600a -
*Static Cooling (S) / Fan Cooling (F)
L/MBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
EMT 17CLP
220-240V 50Hz
LBP
3.40
187 - 255
S
ISO7
38
0.97
EMX 20CLC
220-240V 50Hz
LBP
3.97
198 - 254
S
ISO5
46
1.24
EMY 20CLC
220-240V 50Hz
LBP
3.97
198 - 254
S
ISO5
46
1.15
EMZ 20CLC
220-240V 50Hz
LBP
3.97
187 - 255
S
ISO5
50
1.30
EMT 23CLP
220-240V 50Hz
LBP
4.50
187 - 255
S
ISO7
58
1.08
EMT 35CLP
100V 50-60Hz
LBP
4.50
85 - 110
S
ISO7
60
1.03
EMY 26CLC
220-240V 50Hz
LBP
5.19
198 - 254
S
ISO5
62
1.22
EMZ 26CLC
220-240V 50Hz
LBP
5.19
198 - 254
S
ISO5
62
1.26
EMX 26CLC
220-240V 50Hz
LBP
5.19
187 - 255
S
ISO5
63
1.34
EMT 26CLP
220-240V 50Hz
L/MBP
5.19
187 - 255
S
ISO7
64
0.98
EMU 26CLC
220-240V 50Hz
L/MBP
5.19
198 - 254
S
ISO7
64
1.07
EMT 32CLP
220-240V 50Hz
L/MBP
5.96
198 - 254
S
ISO7
73
1.00
EMU 32CLC
220-240V 50Hz
L/MBP
5.96
198 - 254
S
ISO7
73
1.08
EMY 32CLC
220-240V 50Hz
LBP
5.96
198 - 254
S
ISO5
73
1.19
EMZ 32CLC
220-240V 50Hz
LBP
5.96
198 - 254
S
ISO5
73
1.29
EMX 32CLC
220-240V 50Hz
LBP
5.96
187 - 255
S
ISO5
74
1.36
EMU 45CLP
100V 50-60Hz
LBP
5.96
85 - 110
S
ISO10
76
1.07
EMY 40CLC
220-240V 50Hz
LBP
7.23
198 - 254
S
ISO5
89
1.21
EMZ 40CLC
220-240V 50Hz
LBP
7.23
198 - 254
S
ISO5
91
1.30
EMT 40CLP
220-240V 50Hz
L/MBP
7.23
198 - 254
S
ISO7
91
1.01
EMU 40CLC
220-240V 50Hz
L/MBP
7.23
198 - 254
S
ISO7
91
1.10
EMY 46CLP
220-240V 50Hz
L/MBP
7.96
198 - 254
S
ISO7
101
1.15
EMT 46CLP
220-240V 50Hz
L/MBP
7.96
198 - 254
S
ISO7
102
1.02
EMU 46CLC
220-240V 50Hz
L/MBP
7.96
198 - 254
S
ISO7
102
1.10
EMZ 46CLC
220-240V 50Hz
LBP
7.96
187 - 255
S
ISO7
106
1.36
EMY 46CLC
220-240V 50Hz
LBP
7.96
187 - 255
S
ISO7
106
1.27
EMT 56CLP
220-240V 50Hz
LBP
9.34
198 - 254
S
ISO7
116
1.06
EMZ 55CLC
220-240V 50Hz
LBP
9.04
198 - 254
S
ISO5
117
1.31
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
16
R-600a -
L/MBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
EMX 55CLC
220-240V 50Hz
LBP
9.04
187 - 255
S
ISO5
118
1.37
EMX 66CLC
220-240V 50Hz
LBP
10.61
187 - 255
S
ISO5
137
1.37
EMX 70CLC
220-240V 50Hz
LBP
11.14
198 - 255
S
ISO5
143
1.36
EGX 80CLC
220-240V 50Hz
LBP
11.14
198 - 255
S
ISO5
149
1.47
EMZ 70CLC
220-240V 50Hz
LBP
11.14
187 - 255
S
ISO7
153
1.36
EGX 90CLC
220-240V 50Hz
LBP
12.21
198 - 255
S
ISO5
162
1.49
EGZ 90CLC
220-240V 50Hz
LBP
12.21
198 - 255
S
ISO7
167
1.40
Note: Condensing Temperature 54.4ºC (129.92ºF)
Blends -
*Static Cooling (S) / Fan Cooling (F)
L/MBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
EM 30NP
220-240V 50Hz
LBP
3.00
198 - 255
S
ISO32
55
0.73
EMI 55ER
220-240V 50-60Hz
LBP
4.60
198 - 255
S/F
ISO32
104
0.99
EM 55NP
220-240V 50Hz
LBP
4.99
198 - 255
S
ISO32
106
0.86
EM 65NP
220-240V 50Hz
LBP
5.54
198 - 255
S
ISO32
123
0.90
FF 7.5BK
220-240V 50Hz
L/M/HBP
6.92
198 - 255
S
ISO32
902
1.60
FFU 70AK
220-240V 50-60Hz
L/MBP
6.36
187 - 255
S/F
ISO32
158
1.11
FF 8.5BK
220-240V 50Hz
L/M/HBP
7.95
198 - 255
S/F
ISO32
695
1.71
FFU 80AK
220-240V 50-60Hz
L/MBP
6.76
187 - 255
S/F
ISO32
169
1.10
FF 10BK
220-240V 50Hz
L/M/HBP
9.04
198 - 255
F
ISO32
632
1.70
FFI 12BK
220-240V 50Hz
L/M/HBP
11.14
198 - 255
F
ISO32
902
1.77
Note: Condensing Temperature 54.4ºC (129.92ºF)
Blends -
*Static Cooling (S) / Fan Cooling (F)
M/HBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
CHECK POINT DATA
CECOMAF (CALCULATED)
COOLING
TYPE*
OIL VISCOSITY
CAPACITY
W
COP
W/W
FF 7.5BK
220-240V 50Hz
L/M/HBP
6.92
198 - 255
S
ISO32
902
1.60
FF 8.5BK
220-240V 50Hz
L/M/HBP
7.95
198 - 255
S/F
ISO32
695
1.71
FF 10BK
220-240V 50Hz
L/M/HBP
9.04
198 - 255
F
ISO32
632
1.70
FFI 12BK
220-240V 50Hz
L/M/HBP
11.14
198 - 255
F
ISO32
902
1.77
Note: Condensing Temperature 54.4ºC (129.92ºF)
R-290 -
*Static Cooling (S) / Fan Cooling (F)
L/MBP - 50Hz
MODEL
VOLTAGE / FREQUENCY
APPLICATION
DISPLACEMENT
OPERATING
VOLTAGE
RANGE
cm³
V
COOLING
TYPE*
CHECK POINT DATA
CECOMAF (CALCULATED)
OIL VISCOSITY
CAPACITY
W
COP
W/W
FFU 130UAX
220-240V 50-60Hz
L/MBP
6.76
187 - 255
F
ISO32
236
1.18
FFU 160UAX
220-240V 50Hz
L/MBP
7.95
187 - 255
F
ISO32
296
1.15
Note: Condensing Temperature 54.4ºC (129.92ºF)
*Static Cooling (S) / Fan Cooling (F)
18
R-600a - R-134a - Blends - R-290
10) - COMPRESSOR HOUSING
EM
EG / F
Suction Connector
Process Connector
Process Connector
179
(7.05)
30º
Suction Connector
203.8
(8.02)
Discharge
Connector
30º
30º
D
C
B
E
A
D
C
78
(3.07)
Earthing Terminal
34
(1.34)
Earthing Terminal
Discharge Connector
106.5
(4.19)
150
(5.91) 32
(1.26)
24º
28º
Oilcooler Tube
96.5
(3.80)
63
(2.36)
42.7
(1.68) 70
(2.76)
40º
40º
44º
44º
92.5
(3.64)
104
(4.09)
203
(7.99)
Ø 19 (0.45) (x4)
170
(6.69)
Ø 16 (0.75) (x6)
101.6 70
(4.00) (2.76)
101.6
(4.00)
113
(4.45)
203
(7.99)
170
(6.69)
Ø 7 (0.276) (x2)
Ø 3.75 (0.148)
131.5
(5.18)
165
(6.50)
165
(6.50)
178
(7.01)
Ø 16 (0.63) (x6)
170
(6.69)
178
(7.01)
203
(7.99)
106.5
(4.19)
100
(3.94)
70
(2.76)
Ø 16 (0.63) (x6)
131.5
(5.18)
Ø 7 (0.276) (x2)
203
(7.99)
Ø 19 (0.75) (x4)
70
(2.76)
178
(7.01)
EM (tall)
EM (short)
Ø 16 (0.63) (x6)
96.5
(3.80)
70
(2.76)
100
(3.94)
170
(6.69)
178
(7.01)
Ø 7 (0.276) (x2)
Dimensions in mm (inches)
COMPRESSORS
A
27º
27º
93
(3.66)
110
(4.33)
98
(3.86)
Ø 3.75 (0.148)
173
(6.81)
35 41
(1.38) (1.61)
B
A
B
C
D
168
(6.61)
157
(6.18)
166
(6.54)
155
(6.10)
150
(5.91)
139
(5.47)
155
(6.10)
144
(5.67)
Dimensions in mm (inches)
COMPRESSORS
EG / F (tall)
EG / F (short)
A
B
C
D
E
109
(4.29)
103
(4.06)
90
(3.54)
84
(3.31)
118
(4.65)
112
(4.41)
201
(7.91)
195
(7.68)
207
(8.15)
201
(7.91)
Compressors may be supplied with either of the above plates. Please make sure you indicate which base should be supplied.
20
R-600a - R-134a - Blends - R-290
11) - ELECTRICAL DIAGRAMS
F / EG COMPRESSORS - CSCR / CSIR / RSCR / RSIR
EM COMPRESSORS - CSCR / CSIR / RSCR / RSIR
Overload Protector
1
4
2
3
3
2
1
Start Capacitor
5
1
6
3
Compressor
Run Capacitor
PTC
3
4
C
PTC
S
3
S
M
4
C
M
Run Capacitor
Compressor
6
3
1
Start Capacitor
5
3
2
4
1
1
2
3
Overload Protector
Compressors with a run capacitor must use PTC
with 3 terminals.
Compressors without run capacitor use PTC
with 1 terminal.
EM COMPRESSORS - CSIR / RSIR
F / EG / PW COMPRESSORS - CSIR / RSIR
Overload Protector
3
1
2
11
11
13
10
Compressor
12
Start Capacitor
M
C
Starting Relay
S
3
Start Capacitor
S
Starting Relay
C
M
14
Compressor
1
3
4
13
1
2
2
4
3
Overload Protector
If application of a start capacitor is necessary, then it
must be connected between terminals 3 and 4.
To achieve this, just rupture this bridge.
If application of a start capacitor is necessary, then it
must be connected between terminals 11 and 13.
This requires a specific relay, with fast on terminals
for better start capacitor installation, which can be
supplied upon request.
22
R-600a - R-134a - Blends - R-290
12) - F COMPRESSOR DENOMINATION
Basic type
F - Relay / External Protector
Relay / External Protector / Start Capacitor (optional)
C
E
I
V
U
-
Electrical system
Standard efficiency
Improved efficiency 1st generation (for commercial refrigeration)
Improved efficiency 1st generation
Improved efficiency 2nd generation
Improved efficiency 3rd generation
Improved efficiency 4th generation
Efficiency level
Approx. compressor displacement in cm3 (for FG, FFU and FFC compressors
approximate capacity in Btu/h - 60Hz - ASHRAE - check point divided by 10)
Refrigerant
Application
Starting characteristic
F
Compressor cooling
U
F
60
G
H
A
W
S
- Without oil cooler
W - With oil cooler
K
X
- LST (low starting torque)
- LST (low starting torque)
- HST (high starting torque)
A - LBP
B - HBP, LBP/HD
H - HBP
H
C
U
G
S
V
T
U
-
-
R-134a
R-600a
R-290
R-404A
Blends
Standard efficiency
Improved efficiency 1st generation
Improved efficiency 2nd generation
Improved efficiency 3rd generation
Improved efficiency 4th generation
Efficiency level
G - PTC / External Protector
PTC / External Protector / Start Cap / Run Cap (optional)
24
Electrical system
R-600a - R-134a - Blends - R-290
14) - EG COMPRESSOR DENOMINATION
Basic type
Efficiency level
Mechanical Kit (Embraco Internal Use)
Capacity/10 - Btu/h (ASHRAE - check point - 60Hz)
Refrigerant
Application
Electrical equipment
Oil cooler
EG
S
Z
100
H
L
P
W
- Without oil cooler
W - With oil cooler
R - Relay
P - PTC + Run Capacitor (optional)
C - PTC + Run Capacitor (mandatory)
X - Relay + Start Capacitor
L - LBP
M - L/M/HBP
H - HBP
- Blends
H - R-134a
C - R-600a
S - Standard
Mechanical Kit
S
T
U
Y
Z
X
or A - Standard
- 1st Generation
- 2nd Generation
- 3rd Generation
- 4th Generation
- 5th Generation
- 6th Generation
26
27
28

Similar documents