Centrifugal Fans RDH belt driven
Transcription
Centrifugal Fans RDH belt driven
Centrifugal Fans RDH belt driven Issue 2.5 EN August 2013 1 AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0160 to 0560, RDH-E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0180 to 0560, ADH and RDH fans of the L, R, K, K1 and K2 versions, from sizes 0630 to 1000, AT fans of the S, SC, C and TIC versions, from sizes 7/7 to 30/28, shown herein are licensed to bear the AMCA Seal. Nicotra Gebhardt GmbH (Germany) certifies that RZR fans of the 11, 12, 15 versions, from sizes 0355 to 1000, shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Air performance with Installation Type “A” (“with free outlet”), and that of the twin fan versions G2L, G2R, G2K, G2K2, G2E0, G2E2, G2E4, G2E7, SC2, G2C and G2C-C2, and that of the triple fan versions G3C and G3C-C2 in any installation type is not AMCA licensed. Nicotra Gebhardt stands for: A Maximised flexibility and minimised design effort for customers, because all radial fan casings have identical dimensions – no matter what kind of impeller geometry A Top product quality and shorter delivery times – thanks to state-of-the-art production technology A Energy efficiency through comprehensive system know-how I The Nicotra Gebhardt portfolio A strong provider for many optimal solutions When it comes to radial fans, we are the first people you should talk to. From belt-driven radial fans to plugfans, it’s all there in our product portfolio. We offer the largest, most comprehensive range of products in this area – and of course the matching services. ADH-E / ADH AT RDH-E / RDH RZR double-inlet forward-curved impeller geometry double-inlet inch diameters forward-curved impeller geometry double-inlet backward-curved impeller geometry double-inlet hollow aerofoil impeller geometry When everything fits To us, perfection in our product portfolio means that all product series in the area of encased radial fans are attuned to one another and are 100% compatible in their dimensions. How did we do it? By using an identical design for the connection dimensions of every fan size in our newly developed series ADH-E and RDH-E and carefully coordinating our options and accessories. In this way, we have standardised and harmonised our product portfolio in all relevant areas. Well designed, easy to install, economical A system that saves space, time, and money – in an air handling unit or any other application: our compact base frame offers decisive advantages: A The frame lengths have been optimised and adjusted for the casing position and motor installation height to achieve the smallest possible overall height and length A Exact, optimised coordination of all components, all the way through to installation, adjustment and testing A Suitable for all fans of the series ADH-E0, RDH-E0 and RZR-11 up to size 0500 II The compact base frame from Nicotra Gebhardt proSELECTA II Simple and reliable selection proSELECTA II is a technical selection program that allows you to configure your own individually designed fan. It provides you with the opportunity to choose from the entire range of fan types and their associated options. The result from proSELECTA II is the provision of all the technical data for your fan, including sound level data, dimension specifications and accessories. Apart from that, as a registered user, your purchase prices are provided. Additionally fully dimensioned drawings in DXF format are available, which can be downloaded and transferred straight into your CAD system. So that you can be sure Models and options that are technically not permissible, are automatically excluded in proSELECTA II. So there is no chance that you will configure a “wrong” device option. What else is important to you During the fan selection process, you can choose any of the standardised ATEX options. Free registration and many advantages You can register as a proSELECTA II user with us, which enables us to offer you faster order processing. What this means for you is: A The complete configuration of your fan with its associated system accessories and belt drive layout. A The possibility to produce fans that operate via a frequency inverter. A The option of saving your own fan configuration on our server. A The opportunity to modify your saved configuration, even over the phone to your Nicotra Gebhardt representative. 2 A Volume up to 300,000 m³/h A Pressure up to 2,200 Pa ADH High performance centrifugal fan ADH double inlet for belt drive impeller with forward curved blades of galvanised sheet steel A Volume up to 65,000 m³/h A Pressure up to 2,500 Pa AT High performance centrifugal fan AT double inlet for belt drive impeller with forward curved blades of galvanised sheet steel A Volume up to 290,000 m³/h A Pressure up to 3,500 Pa RDH High performance centrifugal fan RDH double inlet for belt drive centrifugal impeller with backward inclined blades A Volume up to 300,000 m³/h A Pressure up to 3,500 Pa RZR High performance centrifugal fan RZR double inlet for belt drive high performance impeller with backward curved hollow section true aerofoil blades Fittings / Accessories Accessories Ac omplete system accessories Am iscellaneous fittings Description 3 Description A technical description A operating limits Working towards perfection The RDH E and RDH series Like the ADH E range, with the serie RDH E we have taken the next logical step in further developing our successful RDH range of models. The aim of our development work is to ensure that the dimensions of all casing for the RDH E and RDH range are compatible with the relevant sister models from the forward-curved series (ADH E and ADH). In future, we will also ensure compatibility with the hollow aerofoil impeller types from the RZR series. As part of the development work being undertaken across all product ranges, the quality of the RDH E series has also been improved. For example, it now has standing seam casing which is manufactured during a fully automatic process, and the impeller shaft is galvanised. New choice of models Whether you are looking for single or twin fans, the new RDH E series offers impressive further improvements in terms of functionality and potential uses, whatever the application. The ultimate in compatibility The RDH E and RDH also entail minimised design effort for you, which means that: All accessories and equipment are carefully coordinated (and identical with the ADH E/ADH). The connection dimensions for RDH E (sizes 0180 to 0560) are identical with the corresponding models from the old range RDH and the ranges ADH/ADH E. The models for sizes RDH 0630 to 1000 remain unchanged. All RDH E models up to size 0500 are compatible with the new compact base frame – a unique feature which makes completing your system ultra simple and affordable! Top quality for performance and a long service life! Alongside an intelligent construction, aspects such as the quality of materials and workmanship play a crucial role in ensuring a long life cycle. That’s why – like the ADH E – we have made the casing of the new RDH E even sturdier by means of a standing seam construction. Apart from that, the tried and tested quality of our successful, long-standing RDH series remains the same. And that means robust impeller constructions, non-corrosive impeller shafts and quality bearings – for a long life with minimum noise. 4 The product range at a glance The technical specifications of the RDH E and RDH series. The standard series are designed for permanent ventilation at up to +80 °C resp. +100 °C. According to DIN 24166, the specifications conform to accuracy class 1 (for all sizes from 0355 to 1000) and accuracy class 2 (for all sizes from 0180 to 315). RDH E and RDH G2E series RDH and RDH G2-0630/-1000 series Sizes 0180 to 0560 Scroll of galvanesed sheet steel with standing seam and V-cut off Centrifugal impeller with 11 backward inclined blades made of sheet steel (0250-0560), welded and coated with galvanised shaft Volume up to 90.000 m3/h Pressure up to 3.500 Pa S izes 0630 up to 1000 L ap jointed scroll of galvanised sheet steel assembled by Pittsburgh lockforming, with V-cut off. H igh performance radial impeller with 11 backward inclined blades made of sheet steel, welded and painted, balanced acc. to ISO 1940. V olume up to 290.000 m3/h Pressure up to 3.500 Pa The RDH E and RDH range of models: The right fan for every specification! Depending on the fan size, the RDH E and RDH series have up to 5 mechanical versions of the single fan and up to 2 additional twin fan options. In this way, we ensure that we have the perfect model for all requirements and any application. Version Description RDH E0 Lap jointed scroll without feet and discharge flange. Light duty bearing execution with pressed steel housing/strut assemblies. RDH E2 / RDH R Lap jointed scroll with rectangular side frame, without discharge flange. Light duty bearing execution with pressed steel housing/strut assemblies. RDH E4 / RDH K Lap jointed scroll with heavy duty reinforced side frames, without discharge flange. Medium duty bearing execution with cast iron pillow block, mounted on a robust pedestal. RDH E6 / RDH K1 Lap jointed scroll with heavy duty reinforced side frames, without discharge flange. Medium-heavy duty bearing execution with cast iron pillow block, mounted on a robust pedestal. RDH E7 / RDH K2 Lap jointed scroll with heavy duty reinforced side frames, without discharge flange. Heavy duty bearing execution with single-piece resp. split-type plummer block, mounted on a robust pedestal. Version Description RDH G2E4 / RDH G2K The two single fans RDH E4 or RDH K are fitted together to a robust assembly by means of 3 angle bars. Both impellers are fitted on a common shaft supported by 3 bearings (sizes 0250/-0630) or the fans have separated shafts being connected by a elastic coupling (sizes 0710/-1000). RDH G2E7 / RDH G2K2 The two single fans RDH E7 or RDH K2 are fitted together to a robust assembly by means of 3 angle bars. Both impellers are fitted on a common shaft supported by 3 bearings (sizes 0250/-0630) or the fans have separated shafts being connected by a elastic coupling (sizes 0710/-1000). Figure Figure 5 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). RDH E_-0180 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Dr z J Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 180 mm 8 0,003 kgm² m r1 0,62 kg 1,2 kg/m³ 2 Performance Curves Please note coloured area! Pa N all types suitable 4500 N do not use in this area % 4000 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 62 58 3500 3000 2500 η r 64 kW 62 1.5 2000 1.0 1500 53 0.8 0.6 41 0.4 1000 0.15 P r 500 0.10 400 95 dB 300 SX 90 200 85 150 100 49 6800 45 45 6000 40 40 5500 36 36 5000 33 33 4500 30 30 4000 26 26 3500 23 23 3000 20 20 2500 16 16 300 400 500 600 0.1 qV 0.8 1 pd2 2 ∆LWrel4(A) 800 1000 0.2 2 v2 Speed 1/min 6000 4500 3000 6000 4500 3000 6000 4500 3000 3 4 0.3 4 6 1500 5 8 10 6 0.4 7 20 8 40 2000 0.5 3000 0.6 9 10 60 80 100 63 125 250 4 3 2 3 2 1 2 1 1 -14 -9 -3 -17 -11 -5 -21 -15 -9 -6 -2 0 -8 -4 -0 -11 -7 -4 -2 -3 -3 -3 -3 -3 -6 -5 -2 500 1000 2000 4000 8000 -5 -3 -3 -5 -4 -4 -4 -4 -4 -5 -5 -4 -6 -4 -3 -6 -4 -3 -6 -8 -9 -5 -8 -10 -5 -8 -9 -11 -12 -15 -12 -13 -15 -11 -12 -14 -17 -18 -21 -17 -18 -22 -16 -17 -21 m³/h 1 0.8 14 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 4000 m³/s 20 200 Pb L N 40 200 WA 7 DX 75 60 pF W 49 80 80 6 W 7500 70 Normal operation area Duty point SX SX SX qV opt qV opt qV opt DX DX DX 1/min RDH E2 0.2 600 RDH E0 29 0.3 800 Measured in installation B according to ISO 5801: m/s 400 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 15 16 10 8 10 8 5 7 5 8 5 6 6 6 7 3 1 0 3 5 5 5 5 3 -2 0 3 500 1000 2000 4000 8000 3 2 -3 1 0 -5 1 -1 -5 -5 -6 -4 -7 -6 -4 -7 -6 -4 -6 -6 -8 -6 -7 -10 -6 -6 -7 -10 -12 -15 -12 -16 -19 -9 -12 -17 -17 -19 -22 -21 -22 -25 -19 -21 -26 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0180 Dimensions in mm, subject to change. RDH E0-0180 5.3 kg 167 319 6 157 322 11 × 16 = 180 229 365 130 135 229 2 × 129.5 285 167 344 30 195 227 227 9 20h7 259 289 154 7 6 22.5 370 229 28 = RDH E2-0180 7.1 kg 320 253 269 9 × 14 8 229 2 × 129.5 285 180 290 229 346 180 30 195 227 9 20h7 111 6 323 157 154 366 370 229 6 22.5 20 130 28 30 7 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). RDH E_-0200 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 200 mm 8 0,006 kgm² 0,84 kg 1,2 kg/m³ 2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4 only 4000 N do not use in this area m r1 η 65 kW 3.0 59 Dr z J 53 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia r 67 3500 3000 2.0 2500 2000 62 1.5 1.0 0.8 46 1500 0.6 100 dB 400 95 SX 300 200 W W W 7600 50 50 50 6800 45 45 45 6000 40 40 40 5500 36 36 36 5000 33 33 33 4500 30 30 30 4000 26 26 26 3500 23 23 23 3000 20 20 20 2500 16 16 16 RDH E4 P 0.15 500 1/min RDH E2 0.2 r 600 29 0.3 800 RDH E0 0.4 1000 90 Normal operation area 150 85 75 DX 100 L WA 7 80 80 qV 400 500 0.1 1 pd2 2 2 8 1000 4 6 1500 0.3 3 4 ∆LWrel4(A) Speed 1/min 5500 4500 3000 5500 4500 3000 5500 4500 3000 800 0.2 v2 Duty point SX SX SX qV opt qV opt qV opt DX DX DX 600 0.4 5 8 10 2000 0.5 6 7 20 8 40 3000 0.6 4000 5000 6000 1 0.8 9 10 60 14 80 100 63 125 250 5 4 3 4 3 1 2 2 0 -5 -5 -5 -4 -3 -0 -7 -6 -3 -5 -5 -5 -2 -1 1 -4 -3 -2 -5 -5 -5 -1 -2 -2 -3 -4 -4 500 1000 2000 4000 8000 -3 -3 -3 -4 -3 -4 -5 -4 -4 -5 -5 -5 -6 -6 -5 -6 -5 -4 -8 -8 -8 -7 -9 -8 -6 -8 -8 -11 -11 -11 -9 -9 -10 -10 -11 -12 -17 -17 -17 -13 -14 -18 -13 -11 -12 20 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 1.4 400 m³/h 2 m³/s 30 m/s Pb 40 300 N pF 60 Measured in installation B according to ISO 5801: 600 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 25 22 14 19 16 14 19 18 10 10 7 7 11 10 9 7 3 2 5 7 7 7 6 3 0 1 1 500 1000 2000 4000 8000 4 2 -2 1 -1 -5 -1 -1 -6 -6 -7 -5 -8 -8 -6 -8 -7 -5 -7 -7 -8 -7 -8 -9 -5 -6 -6 -11 -12 -14 -11 -13 -15 -8 -11 -15 -17 -18 -18 -17 -18 -21 -17 -16 -17 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0200 Dimensions in mm, subject to change. RDH E0-0200 6.6 kg 189 348 6 166 351 11 × 16 = 224 256 400 130 144 256 2 × 143 312 186 378 30 216 258 250 9 20h7 286 316 163 6 6 22.5 420 256 28 = RDH E2-0200 8.5 kg 348 8 286 306 256 2 × 143 312 11 × 16 399 379 224 30 224 312 256 9 20h7 216 258 6 351 166 163 130 113 420 256 6 22.5 25 28 36 RDH E4-0200 11.8 kg 11 × 16 256 2 × 143 312 224 312 399 379 224 30 256 9 20h7 286 306 351 166 216 258 6 163 8 348 113 420 256 6 22.5 25 130 28 36 9 Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0225 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η 69 r 3000 64 2.0 2500 52 1.5 2000 1.0 1500 0.8 35 0.6 1000 0.4 800 0.3 600 r P W W W 6500 43 43 43 6000 5800 40 38 40 38 40 38 5000 33 33 33 4500 30 30 30 4000 26 26 26 3500 23 23 23 3000 20 20 20 2600 17 17 17 2300 15 15 15 2000 13 13 13 95 dB 0.2 500 400 1/min RDH E4 49 4.0 kW 3.0 3500 1,3 kg 1,2 kg/m³ 2 RDH E2 % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4 only 4000 N do not use in this area m r1 RDH E0 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 225 mm 8 0,011 kgm² 66 Dr z J 59 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). 0.12 90 300 SX 85 200 Normal operation area 80 150 WA 7 70 DX L 75 100 80 500 600 800 qV 3 2 3 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 10 Speed 1/min 5000 3500 2300 5000 3500 2300 5000 3500 2300 4 1500 0.3 2 v2 pd2 1000 0.2 5 0.4 4 7 5 10 2000 0.5 6 3000 0.6 7 20 0.8 8 4000 5000 6000 1 9 10 40 60 1.4 63 125 250 5 3 2 3 1 1 2 1 1 -6 -4 4 -6 -4 3 -11 -8 0 -0 3 3 -1 2 1 -4 0 -1 0 -1 1 -1 -3 1 -2 -4 -1 500 1000 2000 4000 8000 -2 -2 -3 -2 -1 -3 -4 -3 -3 -6 -5 -6 -6 -5 -5 -6 -4 -4 -8 -10 -10 -7 -9 -9 -6 -9 -10 -13 -13 -14 -12 -13 -13 -12 -13 -13 -17 -19 -20 -16 -17 -20 -16 -16 -18 m³/s 30 20 80 100 m³/h 2 14 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 8000 400 Pb 40 400 N pF 60 600 Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 21 14 11 16 12 14 14 10 8 8 8 10 11 10 8 6 5 4 7 7 6 6 3 4 2 1 2 500 1000 2000 4000 8000 4 0 -4 1 -1 -6 0 -3 -5 -7 -6 -4 -9 -7 -4 -8 -6 -3 -7 -9 -10 -7 -9 -12 -5 -7 -10 -13 -14 -15 -14 -18 -18 -11 -15 -18 -17 -19 -21 -21 -21 -22 -20 -21 -21 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0225 Dimensions in mm, subject to change. RDH E0-0225 7.8 kg 209 388 6 185 391 11 × 16 = 224 288 443 130 156 288 2 × 159 344 202 422 30 241 287 279 9 20h7 318 348 182 7 6 22.5 450 288 28 = 390 288 2 × 159 344 11 × 16 442 425 224 30 224 351 288 9 20h7 318 338 393 185 241 287 6 182 130 127 450 288 6 22.5 25 11 RDH E2-0225 9.9 kg 28 39 390 288 2 × 159 344 224 351 288 442 425 224 30 11 × 16 393 185 9 20h7 318 338 182 241 287 6 127 450 288 6 22.5 25 11 RDH E4-0225 13.6 kg 130 28 39 11 Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0250 4,87 kg 1,2 kg/m³ 2 7.5 η r 72 3.0 3000 61 2.0 2500 1.5 2000 46 1.0 1500 0.8 0.6 31 1000 0.4 800 P r 0.3 600 1/min W W W 6000 40 40 72 5400 36 36 65 4600 30 30 55 4000 26 26 48 3600 24 24 43 3200 21 21 38 2800 18 18 34 2300 15 15 28 1800 12 12 22 RDH E4 3500 5.5 76 kW 4.0 RDH E2 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4 only 4000 N do not use in this area m r1 RDH E0 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 252 mm 11 0,044 kgm² 67 Dr z J 53 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). 0.2 500 100 dB 400 300 SX 95 75 200 90 Normal operation area DX 150 85 80 L 80 WA 7 100 600 qV 800 12 Speed 1/min 4600 3200 2300 4600 3200 2300 4600 3200 2300 2000 3000 0.4 0.5 0.6 2 3 4 5 6 2 4 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 1500 0.3 v2 pd2 1000 0.2 6 8 10 4000 5000 6000 0.8 7 20 8 1 1.4 9 10 40 60 63 125 250 3 3 2 4 4 3 3 3 3 -8 -7 -4 -10 -9 -8 -10 -7 -7 -7 -3 -3 -10 -8 -6 -9 -8 -7 -5 -4 -3 -8 -7 -7 -9 -8 -8 80 100 500 1000 2000 4000 8000 -4 0 -1 -8 -1 -1 -7 -3 -3 -4 -8 -6 -3 -7 -5 -5 -6 -4 -9 -9 -10 -7 -7 -8 -6 -6 -7 -13 -13 -15 -10 -12 -15 -9 -10 -13 m³/h 3 m³/s 20 30 14 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 8000 10000 2 -18 -19 -20 -17 -19 -21 -15 -19 -21 400 600 Pb 40 500 N pF 60 Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 6 9 10 6 7 6 5 7 6 7 7 6 5 4 2 4 3 1 3 3 2 0 -1 -2 -2 -2 -2 500 1000 2000 4000 8000 -2 0 -1 -5 -2 -2 -4 -2 -3 -4 -7 -3 -4 -5 -1 -4 -5 -1 -6 -4 -5 -3 -1 -3 -2 -1 -3 -8 -11 -13 -5 -9 -13 -4 -8 -11 -16 -18 -19 -15 -18 -20 -13 -16 -19 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0250 Dimensions in mm, subject to change. RDH E0-0250 13.3 kg 232 423 6 198 426 11 × 16 = 224 322 488 130 161 322 2 × 176 378 215 467 30 268 322 304 9 20h7 352 382 195 7 6 22.5 485 322 28 = 425 322 2 × 176 378 11 × 16 488 470 224 30 224 386 322 9 20h7 352 372 428 198 268 322 6 195 130 138 485 322 6 22.5 25 10 RDH E2-0250 15.7 kg 28 39 425 11 × 16 322 2 × 176 378 224 386 488 470 224 40 322 9 25h7 352 372 428 198 268 322 8 195 138 515 322 7 28 25 10 RDH E4-0250 21 kg 130 28 39 13 Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0280 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) kW 4.0 3500 5,89 kg 1,2 kg/m³ 2 5.5 7.5 r 2500 72 3.0 3000 61 2.0 2000 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η 76 Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4 only 4000 N do not use in this area m r1 67 282 mm 11 0,069 kgm² % Dr z J 55 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). 1.5 45 1.0 1500 0.8 r P 0.2 500 400 300 SX 95 dB W W W 5100 61 61 77 4700 56 56 71 4300 52 52 65 4000 48 48 60 3600 43 43 54 3200 38 38 48 2800 34 34 42 2400 29 29 36 2000 24 24 30 1800 22 22 27 1600 19 19 24 RDH E4 0.3 600 1/min RDH E2 29 0.4 800 RDH E0 0.6 1000 75 200 Normal operation area 90 DX 150 85 100 WA 7 80 L 80 600 qV 800 2 ∆LWrel4(A) 14 0.4 2 0.8 1 pd2 Speed 1/min 4300 2800 1800 4300 2800 1800 4300 2800 1800 1500 0.3 v2 Duty point SX SX SX qV opt qV opt qV opt DX DX DX 1000 0.2 2000 0.5 3 3 4 5 4 7 3000 0.6 0.8 5 10 6 4000 5000 6000 1 7 20 1.4 8 40 9 10 60 63 125 250 3 3 3 4 3 4 3 4 4 -8 -7 -1 -10 -9 -6 -9 -7 -6 -6 -4 -1 -9 -7 -5 -9 -8 -6 -5 -4 0 -8 -7 -2 -9 -8 -3 500 1000 2000 4000 8000 -5 -1 -4 -8 -1 -5 -8 -3 -5 -4 -8 -5 -4 -7 -4 -4 -7 -4 -9 -8 -8 -7 -6 -7 -6 -5 -6 -12 -13 -14 -10 -12 -14 -8 -11 -14 -16 -18 -19 -15 -18 -20 -14 -18 -22 m³/h 3 m³/s 14 80 100 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 8000 10000 2 Measured in installation B according to ISO 5801: m/s 20 200 Pb 40 500 N pF 60 400 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 7 10 11 7 7 7 6 7 7 7 6 7 5 3 2 4 2 2 3 2 5 0 -1 2 -1 -2 3 500 1000 2000 4000 8000 -3 -1 -3 -6 -3 -4 -4 -1 -3 -4 -5 0 -5 -4 1 -3 -4 1 -4 -3 -5 -2 0 -4 -2 0 -3 -8 -11 -13 -5 -10 -13 -4 -8 -11 -15 -17 -18 -14 -17 -19 -12 -16 -19 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0280 Dimensions in mm, subject to change. RDH E0-0280 17.8 kg 8 218 474 11 × 16 = 280 361 546 130 183 361 2 × 195.5 417 242 524 40 302 361 242 9 25h7 391 421 215 6 261 471 7 28 555 361 28 = RDH E2-0280 21 kg 391 421 361 2 × 195.5 417 13 × 18 545 526 280 40 280 435 361 9 25h7 302 361 8 475 218 215 9 472 130 156 555 361 7 28 30 28 37 RDH E4-0280 28 kg 13 × 18 361 2 × 195.5 417 280 435 545 526 280 40 361 9 30h7 391 421 475 218 302 361 8 215 9 472 156 580 361 7 33 30 130 28 37 15 Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0315 3.0 48 2.0 1500 1.5 1000 31 1.0 0.8 800 0.6 105 dB P r 600 1/min W W W W 4500 54 54 68 225 4100 49 49 62 205 3500 42 42 53 175 3100 37 37 47 155 2800 34 34 42 140 2400 29 29 36 120 2000 24 24 30 100 1800 22 22 27 90 1600 19 19 24 80 1400 17 17 21 70 RDH E6 Pb 2000 63 4.0 RDH E4 5.5 2500 RDH E2 r 73 3000 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η 77 kW 7.5 7,14 kg 1,2 kg/m³ 2 72 Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4/E6 only 4000 N RDH E6 only 3500 N do not use in this area m r1 RDH E0 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 317 mm 11 0,110 kgm² % Dr z J 59 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). 0.4 500 100 400 300 SX 95 200 75 Normal operation area 90 DX 150 85 100 WA 7 80 L 80 40 1000 N pF 60 1500 0.3 qV v2 0.4 2000 0.5 2 2 pd2 3 3 4 5 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 16 Speed 1/min 4100 2800 1600 4100 2800 1600 4100 2800 1600 3000 0.6 4 7 4000 5000 6000 0.8 1 5 6 10 8000 10000 1.4 7 20 8 2 9 10 40 60 15000 3 4 14 20 80 100 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 63 125 250 4 4 3 4 4 4 3 3 3 -7 -7 0 -9 -9 -5 -9 -7 -6 -5 -4 -1 -9 -7 -5 -9 -8 -5 -4 -4 2 -8 -7 0 -9 -8 0 500 1000 2000 4000 8000 -4 -0 -2 -6 -1 -4 -7 0 -3 -3 -6 -8 -3 -8 -7 -2 -7 -6 -11 -12 -10 -11 -11 -9 -10 -10 -8 -15 -14 -14 -14 -13 -14 -12 -12 -15 -18 -18 -18 -18 -19 -20 -16 -19 -22 20000 5 7 m³/s 40 30 400 m³/h 6 Measured in installation B according to ISO 5801: m/s 600 800 1000 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 8 11 11 7 7 7 6 6 6 8 7 7 5 3 2 4 2 2 4 3 6 0 -1 4 -2 -2 5 500 1000 2000 4000 8000 -1 -1 0 -3 0 -2 -3 1 -1 -3 -3 -2 -3 -4 -1 -1 -3 -1 -6 -7 -7 -6 -6 -6 -5 -5 -5 -11 -12 -13 -10 -11 -13 -8 -9 -12 -17 -17 -18 -16 -18 -19 -14 -17 -20 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0315 Dimensions in mm, subject to change. RDH E0-0315 21 kg 8 239 525 11 × 16 = 280 404 607 130 202 404 2 × 217 460 267 586 40 338 403 376 9 25h7 434 464 236 7 289 522 7 28 600 404 28 = 524 404 2 × 217 460 13 × 18 606 588 280 40 280 486 404 9 25h7 434 464 527 239 338 403 8 236 130 175 600 404 7 28 30 10 RDH E2-0315 25 kg 28 38 524 404 2 × 217 460 13 × 18 606 588 280 40 280 486 404 9 30h7 434 464 527 239 338 403 8 236 130 175 625 404 7 33 30 10 RDH E4-0315 32 kg 28 38 524 13 × 18 404 2 × 217 460 280 486 606 588 280 40 404 9 30h7 434 464 527 239 338 403 8 236 175 625 404 7 33 30 10 RDH E6-0315 34 kg 130 28 38 17 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 357 mm 11 0,200 kgm² % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4/E6 only 4000 N RDH E6 only 3500 N do not use in this area m r1 54 11 15 kW 7.5 3000 10,2 kg 1,2 kg/m³ 1 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η r 73 Dr z J 70 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia 77 RDH E_-0355 5.5 62 2500 4.0 2000 47 3.0 1500 2.0 0.6 600 500 W W 63 60 57 71 68 65 260 248 236 3300 50 50 56 205 2800 42 42 48 174 2400 36 36 41 149 2000 30 30 34 124 1800 27 27 31 112 1600 24 24 27 99 1400 21 21 24 87 1200 18 18 20 74 105 dB r 0.4 P 400 W 63 60 57 RDH E6 Pb 0.8 W 4200 4000 3800 RDH E4 800 1/min RDH E2 1.0 RDH E0 31 1.5 1000 100 0.3 300 SX 95 200 Normal operation area 75 90 DX 150 85 80 WA 7 100 L 80 40 1000 N pF 60 1500 0.3 qV 0.4 1.4 v2 pd2 2000 0.5 2 2 3 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 18 Speed 1/min 3800 2400 1400 3800 2400 1400 3800 2400 1400 4 3000 0.6 0.8 3 4 5 7 4000 5000 6000 1 5 10 8000 10000 1.4 6 7 20 2 8 9 10 40 15000 3 60 4 14 80 100 200 63 125 250 5 4 4 6 4 4 4 3 3 -7 -5 0 -9 -8 -4 -8 -7 -5 -5 -3 0 -8 -7 -4 -8 -8 -5 -4 -3 3 -7 -7 2 -8 -8 2 500 1000 2000 4000 8000 -2 -1 -3 -3 -1 -3 -3 0 -3 -6 -7 -7 -5 -6 -7 -5 -6 -6 -11 -12 -9 -10 -11 -9 -9 -10 -9 -14 -14 -14 -12 -13 -14 -11 -13 -16 -17 -18 -18 -17 -18 -19 -17 -20 -22 m³/h 6 7 m³/s 30 20 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 20000 5 400 600 Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 11 11 11 9 7 7 7 6 5 9 7 7 7 3 2 4 1 2 5 4 7 2 -1 6 -1 -2 7 500 1000 2000 4000 8000 1 0 0 0 -1 0 0 1 0 -5 -3 -2 -4 -2 -1 -3 -2 -1 -6 -7 -7 -4 -6 -6 -4 -6 -6 -10 -12 -13 -9 -11 -13 -8 -10 -13 -16 -17 -18 -15 -17 -19 -14 -17 -20 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0355 Dimensions in mm, subject to change. RDH E0-0355 29 kg 8 264 585 11 × 16 = 355 453 679 130 212 453 2 × 241.5 509 281 658 40 381 450 418 9 30h7 493 533 261 7 327 582 7 33 675 453 28 = 586 453 2 × 241.5 509 13 × 18 680 665 355 40 355 547 453 9 30h7 493 533 589 264 381 450 8 261 130 202 675 453 7 33 40 13 RDH E2-0355 34 kg 28 39 586 453 2 × 241.5 509 13 × 18 680 665 355 50 355 547 453 9 35h7 493 533 589 264 381 450 10 261 130 202 685 453 8 38 40 13 RDH E4-0355 46 kg 28 39 586 13 × 18 453 2 × 241.5 509 355 547 680 665 355 50 453 9 35h7 493 533 589 264 381 450 10 261 202 685 453 8 38 40 13 RDH E6-0355 47 kg 130 28 39 19 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). RDH E_-0400 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4/E6 only 4000 N RDH E6 only 3500 N do not use in this area 12,7 kg 1,2 kg/m³ 1 15 18.5 η r 2500 63 7.5 3000 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 74 kW 11 m r1 78 402 mm 11 0,330 kgm² 71 Dr z J 58 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia 5.0 4.0 2000 46 3.0 1500 2.0 600 0.6 105 dB 500 0.4 400 100 SX 300 75 95 Normal operation area DX 150 80 90 100 WA 7 200 W W 57 65 236 3500 53 53 60 217 3100 47 47 53 192 2900 44 44 49 180 2700 41 41 46 167 2400 36 36 41 149 2200 33 33 37 136 2000 30 30 34 124 1800 27 27 31 112 1600 24 24 27 99 1400 21 21 24 87 1200 18 18 20 74 L 85 W 57 RDH E6 Pb P r 0.8 W 3800 RDH E4 800 1/min RDH E2 30 1.0 RDH E0 1.5 1000 80 40 1500 qV v2 N pF 60 2000 0.5 3000 0.6 0.8 2 2 pd2 3 3 4 5 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 20 Speed 1/min 3100 2400 1400 3100 2400 1400 3100 2400 1400 4000 5000 6000 1 1.4 4 7 5 10 8000 10000 2 6 7 20 15000 3 8 4 9 10 40 60 14 20000 5 63 125 250 3 3 3 3 3 3 2 3 3 -7 -5 0 -9 -8 -4 -7 -7 -5 -3 -3 0 -7 -7 -4 -8 -8 -5 -4 -3 3 -7 -7 2 -8 -8 2 80 100 200 500 1000 2000 4000 8000 -1 -1 -3 -1 -1 -4 -1 0 -4 -6 -6 -6 -6 -6 -5 -7 -7 -5 -10 -8 -9 -9 -8 -8 -9 -8 -8 -11 -13 -13 -10 -13 -14 -10 -12 -15 7 -16 -17 -17 -17 -18 -18 -17 -20 -21 8 30 20 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 30000 6 400 m³/h 9 10 m³/s Measured in installation B according to ISO 5801: 40 m/s 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 10 10 10 7 10 6 6 5 5 7 6 6 4 7 2 2 0 1 3 2 6 -1 3 6 -2 -3 6 500 1000 2000 4000 8000 -1 -2 0 0 0 -1 0 0 -1 -4 -2 -1 -4 -2 0 -4 -4 -1 -4 -4 -7 -3 -3 -6 -4 -3 -5 -8 -11 -12 -8 -11 -13 -7 -10 -13 -15 -16 -16 -15 -17 -18 -15 -17 -19 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0400 Dimensions in mm, subject to change. RDH E0-0400 36 kg 8 293 657 11 × 16 = 355 507 766 130 234 507 537 563 745 200 309 40 432 507 469 9 30h7 547 587 290 7 366 654 7 33 725 507 28 = 657 200 507 537 563 13 × 18 355 614 507 767 40 432 507 9 30h7 547 587 660 293 130 232 8 290 750 355 725 507 7 33 40 11 RDH E2-0400 42 kg 28 43 657 200 507 537 563 13 × 18 355 614 507 767 50 432 507 9 35h7 547 587 660 293 130 232 10 290 750 355 750 507 8 38 40 11 RDH E4-0400 57 kg 28 43 657 507 537 563 355 614 507 767 200 432 507 50 13 × 18 660 293 9 35h7 547 587 290 232 10 750 355 750 507 8 38 40 11 RDH E6-0400 58 kg 130 28 43 21 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). RDH E_-0450 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) kW 15 17,6 kg 1,2 kg/m³ 1 22 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η 78 Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4/E6 only 4000 N RDH E6 only 3500 N do not use in this area m r1 68 452 mm 11 0,520 kgm² % r 11 74 Dr z J 51 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia 3000 2000 61 7.5 2500 5.0 1500 45 4.0 3.0 600 0.8 105 dB P r 500 400 0.6 0.4 100 SX 300 95 200 Normal operation area 75 90 DX 150 85 100 WA 7 80 L 80 W W W 58 58 71 272 3200 54 54 67 256 2800 48 48 59 224 2500 43 43 52 200 2200 37 37 46 176 2000 34 34 42 160 1800 31 31 38 144 1600 27 27 34 128 1400 24 24 29 112 1200 20 20 25 96 1100 17 17 21 80 1000 17 17 21 80 RDH E6 Pb 1.0 W 3400 RDH E4 800 1/min RDH E2 1.5 RDH E0 30 2.0 1000 40 1500 qV N pF 60 2000 0.5 22 Speed 1/min 2800 2000 1200 2800 2000 1200 2800 2000 1200 1 2 3 4 5 8000 10000 1.4 3 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 4000 5000 6000 0.8 2 1.4 v2 pd2 3000 0.6 4 7 2 5 10 6 15000 3 7 20 8 40 20000 4 9 10 60 5 14 80 100 63 125 250 3 3 3 3 3 3 3 3 3 -7 -3 1 -9 -7 -4 -7 -7 -5 -4 -2 0 -7 -5 -4 -8 -6 -5 -4 -1 3 -7 -4 3 -8 -5 3 500 1000 2000 4000 8000 0 -1 -3 -1 -1 -2 0 -1 -3 -7 -6 -7 -6 -5 -6 -7 -6 -6 -10 -10 -10 -9 -9 -10 -9 -9 -10 -13 -13 -15 -12 -13 -15 -13 -14 -17 -17 -19 -20 -17 -19 -21 -19 -21 -24 7 8 20 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 30000 6 m³/h 9 10 m³/s 30 400 600 Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 10 10 6 6 6 6 6 6 4 6 6 0 2 2 2 1 0 1 2 3 0 -2 0 6 -3 0 6 500 1000 2000 4000 8000 0 0 1 -2 -2 2 1 0 1 -4 -2 -2 -3 0 -1 -4 -1 -2 -5 -6 -8 -3 -5 -8 -4 -5 -8 -11 -12 -14 -10 -12 -15 -10 -12 -15 -16 -18 -20 -16 -19 -21 -17 -19 -22 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0450 Dimensions in mm, subject to change. RDH E0-0450 50 kg 325 735 13 × 18 = 530 569 859 130 260 569 599 625 838 200 344 50 487 571 526 9 35h7 619 665 322 7 10 415 732 8 38 815 569 28 = 733 200 569 599 625 13 × 18 530 687 569 858 50 487 571 9 35h7 619 649 736 325 130 259 10 322 841 530 815 569 8 38 40 11 RDH E2-0450 57 kg 28 46 733 200 569 599 625 13 × 18 530 687 569 858 70 487 571 9 40h7 619 649 736 325 130 259 12 322 841 530 850 569 8 43 40 11 RDH E4-0450 73 kg 28 46 733 569 599 625 530 687 569 858 200 487 571 70 13 × 18 736 325 9 40h7 619 649 322 259 12 841 530 850 569 8 43 40 11 RDH E6-0450 75 kg 130 28 46 23 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η 75 r 11 2500 62 8.0 6.0 2000 45 4.0 1500 3.0 1000 29 2.0 1.5 P r 800 1.0 600 0.8 500 105 dB 0.6 400 1/min W W W W 3000 51 63 240 439 2800 2650 48 45 59 56 224 212 410 388 2350 40 49 188 344 2100 36 44 168 307 1800 31 38 144 263 1600 27 34 128 234 1400 24 29 112 205 1200 20 25 96 176 1000 17 21 80 146 900 15 19 72 132 RDH E7 Pb 22 80 kW 15 23,5 kg 1,2 kg/m³ 1 RDH E6 % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4/E6/E7 only 4000 N RDH E6/E7 only 3500 N RDH E7 only N do not use in this area 3000 m r1 RDH E4 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 502 mm 11 0,890 kgm² 69 Dr z J 51 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia RDH E0/E2 RDH E_-0500 100 SX 300 95 200 Normal operation area 150 DX 90 100 85 80 L WA 7 80 40 2000 N pF 60 3000 0.6 qV 0.8 1.4 v2 pd2 4000 5000 6000 1 2 3 2 3 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 24 Speed 1/min 2600 1800 1000 2600 1800 1000 2600 1800 1000 1.4 4 4 5 7 8000 10000 2 5 10 15000 3 6 7 20 4 8 9 10 40 20000 5 60 30000 6 7 14 63 125 250 80 100 2 3 3 1 2 3 2 3 3 -6 -1 2 -9 -6 -2 -8 -6 -3 -4 -1 2 -7 -5 -1 -8 -6 -2 -4 0 2 -8 -2 2 -8 -3 2 500 1000 2000 4000 8000 1 -2 -5 1 -1 -4 1 -1 -3 -9 -9 -7 -9 -8 -7 -7 -7 -6 -13 -11 -11 -12 -10 -11 -11 -9 -10 -14 -15 -14 -14 -15 -15 -13 -14 -15 -18 -18 -18 -19 -19 -19 -19 -19 -21 40000 m³/h 9 10 14 m³/s 30 20 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 8 400 600 Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 9 10 10 8 10 5 5 6 5 5 6 7 5 6 3 0 1 4 1 4 5 1 4 5 -3 2 5 500 1000 2000 4000 8000 1 0 0 1 0 1 1 0 1 -6 -4 -3 -5 -3 -3 -4 -2 -3 -8 -8 -9 -7 -7 -9 -6 -6 -8 -13 -13 -13 -12 -13 -14 -10 -12 -13 -17 -18 -18 -18 -18 -19 -16 -17 -20 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0500 Dimensions in mm, subject to change. RDH E0-0500 62 kg 355 808 13 × 18 = 530 638 949 130 283 638 668 694 928 250 383 50 541 641 576 9 35h7 688 734 352 7 10 456 805 8 38 885 638 28 = 807 250 638 668 694 13 × 18 530 756 638 949 50 541 641 9 35h7 688 718 810 355 130 280 10 352 931 530 885 638 8 38 40 10 RDH E2-0500 70 kg 28 51 807 250 638 668 694 13 × 18 530 756 638 949 70 541 641 9 40h7 688 718 810 355 130 280 12 352 931 530 920 638 8 43 40 10 RDH E4-0500 90 kg 28 51 807 250 638 668 694 13 × 18 530 756 638 949 70 541 641 9 40h7 688 718 810 355 130 280 12 352 931 530 920 638 8 43 40 10 RDH E6-0500 92 kg 28 51 807 638 668 694 530 756 638 949 250 541 641 90 13 × 18 810 355 9 50h7 688 718 352 280 14 931 530 960 638 9 53.5 40 10 RDH E7-0500 110 kg 130 28 51 25 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). 30 37 η r 76 18.5 63 15 2500 10 8.0 2000 46 6.0 1500 4.0 30 3.0 1000 2.0 800 P r 1.5 110 dB 600 1.0 500 0.8 400 105 0.6 300 SX 100 Normal operation area 200 1/min W W W W 2800 59 140 350 355 2600 55 130 325 330 2400 50 120 300 305 2100 44 105 263 267 1950 41 98 244 247 1800 38 90 225 228 1600 34 80 200 203 1400 29 70 175 178 1200 25 60 150 152 1000 21 50 125 127 800 17 40 100 102 RDH E7 Pb Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. RDH E6 kW 25 28,8 kg 1,2 kg/m³ 1 81 Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH E4/E6/E7 only 4000 N RDH E6/E7 only 3500 N RDH E7 only N do not use in this area 3000 m r1 RDH E4 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 562 mm 11 1,410 kgm² 70 Dr z J 50 % Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia RDH E0/E2 RDH E_-0560 95 150 DX 80 90 WA 7 100 L 85 80 40 N pF 60 3000 qV 4000 5000 6000 0.8 1 3 2 3 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 26 Speed 1/min 2400 1800 1000 2400 1800 1000 2400 1800 1000 4 8000 10000 2 2 1.4 v2 pd2 1.4 4 5 7 15000 3 5 10 6 4 7 20 20000 5 8 6 30000 7 9 10 40 60 8 14 63 125 250 80 100 3 3 3 3 3 3 2 3 3 -5 -1 2 -8 -1 -2 -7 -6 -3 -3 -1 2 -7 -1 -1 -8 -6 -2 -3 0 2 -7 0 2 -8 -3 2 500 1000 2000 4000 8000 -1 -1 -4 -1 -2 -4 1 -1 -4 -7 -8 -7 -6 -7 -7 -7 -7 -7 -12 -10 -9 -11 -9 -8 -11 -10 -10 -13 -12 -12 -11 -11 -11 -13 -13 -12 -15 -16 -18 -14 -14 -17 -16 -15 -16 60000 m³/h 14 20 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 40000 9 10 m³/s 30 400 600 Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 10 6 10 6 6 5 5 6 4 6 1 7 2 2 4 0 1 4 2 -2 5 -2 2 5 -3 2 6 500 1000 2000 4000 8000 0 0 0 -2 -1 1 1 1 1 -3 -3 -3 -2 -2 -2 -3 -2 -3 -7 -7 -7 -6 -6 -7 -7 -7 -7 -11 -11 -11 -10 -10 -10 -11 -11 -10 -14 -15 -19 -13 -14 -17 -14 -13 -15 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH E_-0560 Dimensions in mm, subject to change. RDH E0-0560 79 kg 393 900 715 745 771 13 × 18 = 530 715 606 716 1058 130 315 250 425 70 643 1037 9 40h7 765 811 390 7 12 511 897 8 43 1000 715 28 = 901 250 715 745 771 13 × 18 530 851 715 1061 70 606 716 9 40h7 765 815 904 393 130 317 12 390 1046 530 1000 715 8 43 50 13 RDH E2-0560 92 kg 28 50 901 250 715 745 771 13 × 18 530 851 715 1061 90 606 716 9 50h7 765 815 904 393 130 317 14 390 1046 530 1070 715 9 53.5 50 13 RDH E4-0560 141 kg 28 50 901 250 715 745 771 13 × 18 530 851 715 1061 90 606 716 9 50h7 765 815 904 393 130 317 14 390 1046 530 1070 715 9 53.5 50 13 RDH E6-0560 148 kg 28 50 901 715 745 771 530 851 715 1061 250 606 716 90 13 × 18 904 393 9 50h7 765 815 390 317 14 1046 530 1130 715 9 53.5 50 13 RDH E7-0560 153 kg 130 28 50 27 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). r 63 77 10 1500 46 8.0 6.0 30 4.0 1000 3.0 800 2.0 600 1.5 W W W W 2500 52 125 313 317 2300 48 115 288 292 2000 42 100 250 254 1700 36 85 213 216 1600 34 80 200 203 1400 29 70 175 178 1200 25 60 150 152 1000 21 50 125 127 900 19 45 113 114 800 17 40 100 102 700 15 35 88 89 P r 500 1/min RDH K2 Pb η 25 2000 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. RDH K1 15 45 82 18.5 2500 kW 30 36,7 kg 1,2 kg/m³ 1 69 Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH K/K1/K2 only 4000 N RDH K1/K2 only 3500 N RDH K2 only N do not use in this area 3000 m r1 RDH K Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 632 mm 11 2,320 kgm² % Dr z J 49 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia RDH R RDH _-0630 1.0 400 0.8 100 dB SX 300 95 200 Normal operation area 150 DX 90 100 85 qV N pF 40 3000 4000 5000 6000 pd2 2 2 2 3 Speed 1/min 2000 1400 800 2000 1400 800 2000 1400 800 4 5 15000 3 3 ∆LWrel4(A) 28 8000 10000 1 v2 Duty point SX SX SX qV opt qV opt qV opt DX DX DX L 80 60 WA 7 80 4 7 4 5 10 6 20000 5 7 20 8 40 30000 6 7 8 9 10 60 40000 9 10 63 125 250 3 3 3 3 3 3 3 3 3 3 5 8 0 2 3 -4 -2 1 3 4 7 -1 -2 6 -4 -3 6 1 3 3 -2 3 3 -2 2 3 200 -7 -8 -7 -6 -7 -7 -6 -7 -6 -12 -12 -12 -11 -11 -11 -11 -10 -11 -15 -16 -13 -14 -15 -13 -13 -16 -16 -18 -18 -21 -17 -17 -20 -19 -21 -21 m³/h 20 20 80 100 500 1000 2000 4000 8000 -1 -1 -4 -1 -2 -3 -1 -1 -3 14 14 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 60000 30 400 600 m³/s Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 14 14 15 9 10 9 10 8 8 11 10 8 6 5 6 4 4 8 4 4 6 1 2 5 2 4 5 500 1000 2000 4000 8000 0 2 2 0 2 3 1 2 2 -2 -3 -4 -1 -1 -4 -1 -2 -3 -8 -9 -11 -7 -9 -10 -7 -8 -8 -14 -15 -13 -13 -14 -12 -11 -13 -14 -18 -18 -21 -17 -17 -20 -17 -19 -22 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH _-0630 Dimensions in mm, subject to change. RDH R-0630 119 kg 996 70 300 851 901 801 831 857 13 × 18 530 940 801 9 1178 40h7 999 437 679 801 12 434 130 349 70 1157 530 1085 801 8 43 50 28 56 RDH K-0630 173 kg 999 300 851 901 801 831 857 13 × 18 1179 90 530 940 801 9 679 801 50h7 1002 437 130 350 14 434 1157 530 1155 801 9 53.5 50 28 59 RDH K1-0630 180 kg 999 300 851 901 801 831 857 13 × 18 1179 90 530 940 801 9 679 801 50h7 1002 437 130 350 14 434 1157 530 1155 801 9 53.5 50 28 59 RDH K2-0630 185 kg 999 13 × 18 801 831 857 530 940 1179 300 801 9 90 851 901 1002 437 679 801 50h7 434 350 14 1157 530 1215 801 9 53.5 50 130 28 59 29 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η 78 r 64 25 22 2500 15 2000 46 10 1500 8.0 1000 30 6.0 4.0 800 W W W W 2200 110 110 372 129 2000 100 100 338 117 1700 85 85 287 100 1500 75 75 254 88 1300 65 65 220 76 1200 60 60 203 70 1100 55 55 186 64 1000 50 50 169 59 900 45 45 152 53 800 40 40 135 47 700 35 35 118 41 P r 3.0 1/min RDH K2 Pb 50 55 45 37 kW 60 kg 1,2 kg/m³ 1 RDH K1 % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH K/K1/K2 only 4000 N RDH K1/K2 only 3500 N RDH K2 only N do not use in this area 3000 m r1 RDH K Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 712 mm 11 4,940 kgm² 83 Dr z J 71 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia RDH R RDH _-0710 600 2.0 500 1.5 105 dB SX 400 300 100 Normal operation area 80 200 DX 95 150 90 WA 7 100 L 85 80 40 N pF 60 5000 6000 qV 1.4 2 2 1.5 v2 pd2 8000 10000 4 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 30 Speed 1/min 2000 1500 800 2000 1500 800 2000 1500 800 3 3 2 15000 4 4 6 20000 5 8 10 5 6 30000 6 7 20 7 8 8 60000 9 10 9 10 40 40000 60 12 14 14 80 100 63 125 250 3 3 3 3 3 3 3 3 3 1 3 6 -1 0 4 -1 1 4 1 2 7 -1 0 7 -1 0 7 0 3 3 -1 3 2 -1 4 2 500 1000 2000 4000 8000 0 -2 -4 -0 -3 -4 0 -3 -4 -8 -8 -6 -7 -7 -6 -8 -8 -5 -11 -10 -11 -10 -9 -11 -10 -9 -12 -14 -15 -15 -14 -15 -15 -14 -16 -18 -19 -19 -19 -19 -19 -20 -21 -22 -23 m³/h 20 m³/s 20 30 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 80000 400 Measured in installation B according to ISO 5801: m/s 600 800 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 11 11 12 7 8 10 12 11 11 8 8 8 6 6 7 7 7 9 3 4 5 2 3 4 3 6 4 500 1000 2000 4000 8000 1 1 1 0 0 2 1 0 2 -3 -3 -3 -2 -2 -3 -3 -2 -2 -7 -7 -10 -6 -7 -10 -6 -7 -10 -13 -14 -15 -13 -14 -15 -12 -14 -16 -19 -19 -19 -18 -19 -20 -19 -21 -23 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH _-0710 Dimensions in mm, subject to change. RDH R-0710 165 kg 1117 90 400 948 998 898 928 954 17 × 22 630 1050 898 9 1324 50h7 1120 488 765 898 14 485 130 398 90 1303 630 1255 898 9 53.5 50 28 67 RDH K-0710 220 kg 1121 400 948 998 898 928 954 17 × 22 1324 90 630 1050 898 9 765 898 50h7 1123 488 130 398 14 485 1303 630 1255 898 9 53.5 50 28 71 RDH K1-0710 240 kg 1121 400 948 998 898 928 954 17 × 22 1324 90 630 1050 898 9 765 898 60h7 1123 488 130 398 18 485 1303 630 1340 898 11 64 50 28 71 RDH K2-0710 250 kg 1121 17 × 22 898 928 954 630 1050 1324 400 898 9 90 948 998 1123 488 765 898 60h7 485 398 18 1303 630 1340 898 11 64 50 130 28 71 31 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). RDH _-0800 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 802 mm 11 8,250 kgm² 50 % Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH K1/K2 only 4000 N RDH K2 only 3500 N do not use in this area 45 37 86 kg 1,2 kg/m³ 1 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 55 η r 78 kW m r1 83 Dr z J 71 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia 3000 22 64 2500 2000 15 11 46 1500 8.0 W W W 1800 90 304 105 1650 83 279 97 1400 70 237 82 1300 65 220 76 1200 60 203 70 1100 55 186 64 1000 50 169 58 900 45 152 53 800 40 135 47 700 35 118 41 600 30 101 35 RDH K2 P r 3.0 1/min RDH K1 4.0 800 RDH K 30 6.0 1000 2.0 1.5 400 105 dB SX 300 100 Normal operation area 200 80 DX 95 150 90 L 85 80 WA 7 100 8000 10000 qV v2 pd2 32 Speed 1/min 1400 1100 700 1400 1100 700 1400 1100 700 20000 30000 40000 60000 80000 100000 m³/h 2 3 4 5 6 7 8 9 10 14 20 30 m³/s 2 3 4 5 6 7 8 9 10 14 20 30 m/s 30 40 50 60 2 3 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 15000 4 5 6 8 10 20 80 100 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 63 125 250 3 3 3 3 3 3 3 3 3 4 5 7 0 1 4 2 2 4 3 3 8 0 0 8 0 0 8 3 4 2 4 4 1 4 5 1 500 1000 2000 4000 8000 -2 -4 -4 -3 -3 -3 -3 -4 -3 -8 -8 -6 -7 -7 -6 -7 -7 -5 -10 -10 -12 -9 -10 -12 -9 -10 -12 -16 -16 -15 -15 -16 -16 -17 -18 -18 -19 -19 -20 -20 -20 -20 -23 -23 -23 300 400 600 Pb 40 5000 6000 N pF 60 Measured in installation B according to ISO 5801: Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 12 12 12 8 8 9 11 10 11 8 6 8 6 3 7 7 4 9 4 5 5 3 4 4 5 6 4 500 1000 2000 4000 8000 1 1 1 0 1 2 0 1 2 -3 -3 -3 -2 -2 -3 -2 -3 -3 -8 -8 -11 -7 -9 -10 -7 -8 -10 -15 -15 -15 -14 -15 -15 -14 -16 -17 -19 -20 -19 -19 -21 -20 -21 -22 -23 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH _-0800 Dimensions in mm, subject to change. RDH K-0800 270 kg 1255 500 1057 1107 1007 1037 1063 17 × 22 1489 90 710 1181 1007 9 862 1007 50h7 1258 543 130 454 14 540 1468 710 1360 1007 9 53.5 50 28 74 RDH K1-0800 297 kg 1255 500 1057 1107 1007 1037 1063 17 × 22 1489 90 710 1181 1007 9 862 1007 60h7 1258 543 130 454 18 540 1468 710 1450 1007 11 64 50 28 74 RDH K2-0800 305 kg 1255 17 × 22 1007 1037 1063 710 1181 1489 500 1007 9 90 1057 1107 1258 543 862 1007 60h7 540 454 18 1468 710 1450 1007 11 64 50 130 28 74 33 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). 75 83 60 η r 78 45 3000 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 65 30 2500 20 2000 47 15 1500 10 1000 30 8.0 6.0 1/min W W W 1750 140 296 103 1500 120 254 88 1250 100 211 73 1100 88 186 64 1000 80 169 59 900 72 152 53 800 64 135 47 700 56 118 41 600 48 101 35 500 40 85 29 RDH K2 kW 102 kg 1,2 kg/m³ 1 71 Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH K1/K2 only 4000 N RDH K2 only 3500 N do not use in this area m r1 RDH K1 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) 902 mm 11 12,80 kgm² % Dr z J 50 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia RDH K RDH _-0900 800 P r 4.0 600 3.0 500 400 2.0 105 dB 1.5 300 SX 100 200 Normal operation area 95 80 DX 150 90 WA 7 100 L 85 80 qV 8000 10000 2 3 2 34 Speed 1/min 1250 1000 600 1250 1000 600 1250 1000 600 20000 5 3 3 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 4 2 v2 pd2 15000 4 5 6 30000 6 4 7 5 8 10 8 6 20 40000 60000 9 10 80000 100000 14 7 8 30 40 50 60 20 9 10 63 125 250 3 3 3 3 3 3 3 3 3 4 5 6 1 3 3 1 3 4 2 4 8 -1 3 8 -1 3 9 4 4 1 4 4 1 5 4 1 500 1000 2000 4000 8000 -3 -4 -4 -3 -4 -3 -4 -4 -3 -8 -7 -6 -7 -6 -6 -7 -6 -6 -10 -10 -12 -10 -10 -12 -10 -11 -14 -16 -16 -15 -16 -15 -16 -18 -18 -19 -19 -19 -20 -20 -20 -21 -24 -23 -24 20 200 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc dB 30 14 80 100 150000 m³/h m³/s 30 300 400 600 Pb 40 6000 N pF 60 Measured in installation B according to ISO 5801: m/s Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 11 12 10 8 9 8 10 10 9 7 7 9 4 5 8 5 7 10 4 5 5 4 4 5 6 5 5 500 1000 2000 4000 8000 1 1 1 1 2 2 0 1 2 -3 -3 -4 -2 -2 -4 -3 -2 -3 -8 -9 -11 -8 -9 -11 -7 -8 -11 -15 -15 -15 -15 -15 -16 -15 -16 -18 -19 -19 -20 -20 -20 -21 -22 -22 -24 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH _-0900 Dimensions in mm, subject to change. RDH K-0900 343 kg 1408 600 1180 1230 1130 1160 1186 17 × 22 1669 90 800 1319 1130 9 971 1130 60h7 1411 607 130 511 18 604 1648 800 1520 1130 11 64 50 28 89 RDH K1-0900 355 kg 1408 600 1180 1230 1130 1160 1186 17 × 22 1669 90 800 1319 1130 9 971 1130 60h7 1411 607 130 511 18 604 1648 800 1520 1130 11 64 50 28 89 RDH K2-0900 375 kg 1408 17 × 22 1130 1160 1186 800 1319 1669 600 1130 9 90 1180 1230 1411 607 971 1130 60h7 604 511 18 1648 800 1570 1130 11 64 50 130 28 89 35 Belt Driven Centrifugal Fans / RDH / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). RDH _-1000 Impeller Data Impeller weight Density of media Tolerance class (DIN 24166) kW 3500 50 3000 75 60 146 kg 1,2 kg/m³ 1 Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. η 83 Performance Curves Please note coloured area! Pa N all types suitable 4500 N RDH K2 only 4000 N do not use in this area m r1 71 1002 mm 11 24,80 kgm² % Dr z J 50 Technical Data Impeller Data Impeller diameter Number of blades Moment of Inertia r 79 37 2500 65 25 2000 20 15 47 1500 10 1000 400 105 dB W W W 1400 112 237 82 1300 104 220 76 1150 92 195 67 1000 80 169 58 800 64 136 47 700 56 119 41 600 48 102 35 500 40 85 29 450 36 76 26 RDH K2 P 3.0 500 1/min RDH K1 4.0 r 600 30 6.0 800 RDH K 8.0 300 SX 100 200 Normal operation area 95 80 DX 150 90 80 WA 7 100 L 85 qV 8000 10000 2 pd2 3 1.4 v2 1 2 36 Speed 1/min 1150 800 500 1150 800 500 1150 800 500 20000 4 2 ∆LWrel4(A) Duty point SX SX SX qV opt qV opt qV opt DX DX DX 15000 5 6 3 3 4 5 6 30000 7 4 8 10 40000 8 9 10 5 6 20 60000 14 80000 100000 20 7 8 9 10 30 40 50 60 dB 63 125 250 3 3 3 3 3 3 3 3 3 4 7 8 1 4 7 2 4 7 2 7 8 -1 7 7 -1 7 8 4 3 0 4 2 0 5 2 1 500 1000 2000 4000 8000 -4 -4 -3 -3 -4 -2 -4 -4 -2 -8 -6 -6 -7 -5 -6 -7 -5 -6 -10 -11 -11 -10 -11 -12 -10 -12 -13 -16 -15 -15 -16 -15 -16 -18 -18 -19 -19 -19 -20 -20 -20 -21 -24 -23 -23 30 14 m³/s 20 80 100 Relative sound power level for inlet side LWrel7 at octave centre frequencies fc 150000 m³/h 200 Pb 40 6000 N pF 60 Measured in installation B according to ISO 5801: m/s 300 400 Pa Relative sound power level for discharge side LWrel4 at octave centre frequencies fc Hz 63 125 250 dB dB dB dB dB dB dB dB dB 12 12 11 8 10 9 10 11 11 6 8 9 3 7 8 4 9 9 5 5 5 4 4 6 6 4 5 500 1000 2000 4000 8000 1 1 1 1 2 2 0 1 2 -3 -3 -5 -3 -3 -5 -3 -3 -4 -8 -10 -11 -8 -10 -11 -8 -10 -11 -15 -15 -15 -15 -15 -16 -16 -16 -18 -20 -19 -20 -21 -20 -20 -22 -23 -24 Hz dB dB dB dB dB dB dB dB dB Belt Driven Centrifugal Fans / RDH / Technical Data RDH _-1000 Dimensions in mm, subject to change. RDH K-1000 415 kg 1541 700 1317 1367 1267 1297 1323 17 × 22 1829 90 900 1451 1267 9 1066 1267 60h7 1544 660 130 534 18 657 1810 900 1660 1267 11 64 50 28 90 RDH K1-1000 430 kg 1541 700 1317 1367 1267 1297 1323 17 × 22 1829 90 900 1451 1267 9 1066 1267 60h7 1544 660 130 534 18 657 1810 900 1660 1267 11 64 50 28 90 RDH K2-1000 450 kg 1541 17 × 22 1267 1297 1323 900 1451 1829 700 1267 9 90 1317 1367 1544 660 1066 1267 60h7 657 534 18 1810 900 1700 1267 11 64 50 130 28 90 37 Belt Driven Centrifugal Fans / RDH / Twin fan arrangement RDH G2E4 / RDH G2K Dimensions in mm, subject to change. RDH G2E4-0250/-0560 / RDH G2K-0630/-1000 H K E G S M V H1 G1 B1 z B X2 F C t w A2 = E dh7 Q = P RDH G2E4-0250/-0355 13 C2 C2 13 = R RDH G2E4-0400/-0560 RDH G2K-0630 13 13 C2 C2 E2 13 9 C2 E2 RDH G2K-0710/-1000 C2 A2 A2 E2 C2 = = A2 E 322 361 404 453 507 569 638 715 801 898 1007 1130 1267 F 268 302 338 381 432 487 541 606 679 765 862 971 1066 G 195 215 236 261 290 322 352 390 434 485 540 604 657 H 427 474 526 588 659 735 809 903 1005 1121 1255 1408 1541 L 943 1062 1182 1341 1494 1668 1856 2090 2332 2606 2914 3260 3634 M 1085 1220 1340 1505 1660 1870 2060 2330 2576 2898 3257 3550 3927 P 352 391 434 493 547 619 688 765 851 948 1057 1180 1317 0250 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 Q 140 158 177 204 234 261 282 319 349 398 453 510 534 R 37 35 36 37 41 44 49 48 59 71 74 89 90 S 10 9 10 13 11 11 10 13 7 7 8 8 9 V 250 280 315 355 400 450 500 560 630 710 800 900 1000 K 71 79 79 82 83 101 102 120 122 146 172 145 147 X1 224 280 280 355 355 530 530 530 530 630 710 800 900 X2 224 280 280 355 355 530 530 530 530 630 710 800 900 X3 220 250 285 315 360 400 450 510 580 660 750 850 950 t 8 8 8 10 10 12 12 14 14 18 18 18 18 w 40 40 40 50 50 70 70 90 90 91 91 91 91 0250 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 z 28 33 33 38 38 43 43 53.5 53.5 64 64 64 64 ød 25h7 30h7 30h7 35h7 35h7 40h7 40h7 50h7 50h7 60h7 60h7 60h7 60h7 u×s 11 × 16 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 17 × 22 17 × 22 17 × 22 17 × 22 B1 490 547 608 682 769 860 951 1063 1179 1391 1561 1748 1930 H1 430 477 529 591 662 738 812 906 1008 1124 1258 1411 1544 G1 198 218 239 264 293 325 355 393 437 488 543 607 660 A2 322 361 404 453 507 569 638 715 801 898 1007 1130 1267 B2 378 417 460 509 563 625 694 771 857 954 1063 1186 1323 C2 176.0 195.5 217.0 241.5 168.5 199.5 209.0 247.5 265.5 264.0 268.5 280.0 298.5 E2 – – – – 200 200 250 250 300 400 500 600 700 38 C2 13 9 B2 A2 13 13 9 B2 9 RDH G2E4-0250/-0560 / RDH G2K-0630/-1000 A B C 0250 390 474 322 0280 439 530 361 0315 490 592 403 0355 551 669 450 0400 618 754 507 0450 691 845 571 0500 760 935 641 0560 855 1050 716 0630 940 1157 801 0710 1050 1303 898 0800 1181 1468 1007 0900 1319 1648 1130 1000 1451 1810 1267 X1 A = U×S 28 B2 X3 L B2 P 165 max. Belt Driven Centrifugal Fans / RDH / Twin fan arrangement RDH G2E7 / RDH G2K2 M V H K E G H1 G1 B1 z B X2 F C t w A2 = E S Dimensions in mm, subject to change. RDH G2E7-0250/-0560 / RDH G2K2-0630/-1000 dh7 Q = P X1 A = U×S = R RDH G2E7-0250/-0355 RDH G2E7-0400/-0560 RDH G2K2-0630 13 13 13 C2 C2 13 C2 E2 C2 13 9 C2 RDH G2K2-0710/-1000 13 13 C2 E2 C2 = = A2 13 9 B2 A2 RDH G2E7-0250/-0560 / RDH G2K2-0630/-1000 A B C 0250 390 474 322 0280 439 530 361 0315 490 592 403 0355 551 669 450 0400 618 754 507 0450 691 845 571 0500 760 935 641 0560 855 1050 716 0630 940 1157 801 0710 1050 1303 898 0800 1181 1468 1007 0900 1319 1648 1130 1000 1451 1810 1267 E2 9 B2 9 C2 28 B2 X3 L B2 P 165 max. A2 A2 E 322 361 404 453 507 569 638 715 801 898 1007 1130 1267 F 268 302 338 381 432 487 541 606 679 765 862 971 1066 G 195 215 236 261 290 322 352 390 434 485 540 604 657 H 427 474 526 588 659 735 809 903 1005 1121 1255 1408 1541 L 943 1062 1182 1341 1494 1668 1856 2090 2332 2606 2914 3260 3634 M 1085 1230 1400 1545 1800 1924 2146 2380 2576 2898 3257 3550 3927 P 352 391 434 493 547 619 688 765 851 948 1057 1180 1317 0250 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 Q 140 158 177 204 234 261 282 319 349 398 453 510 534 R 37 35 36 37 41 44 49 48 59 71 74 89 90 S 10 9 10 13 11 11 10 13 7 7 8 8 9 V 250 280 315 355 400 450 500 560 630 710 800 900 1000 K 71 84 109 102 153 128 145 145 122 146 172 145 147 X1 224 280 280 355 355 530 530 530 530 630 710 800 900 X2 224 280 280 355 355 530 530 530 530 630 710 800 900 X3 220 250 285 315 360 400 450 510 580 660 750 850 950 t 8 10 12 12 14 14 18 18 18 18 18 18 18 w 40 50 70 70 90 90 90 90 91 91 91 91 91 0250 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 z 33 38 43 43 53.5 53.5 64 64 64 64 64 64 64 ød 30h7 35h7 40h7 40h7 50h7 50h7 60h7 60h7 60h7 60h7 60h7 60h7 60h7 u×s 11 × 16 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 13 × 18 17 × 22 17 × 22 17 × 22 17 × 22 B1 490 547 608 682 769 860 951 1063 1179 1391 1561 1748 1930 H1 430 477 529 591 662 738 812 906 1008 1124 1258 1411 1544 G1 198 218 239 264 293 325 355 393 437 488 543 607 660 A2 322 361 404 453 507 569 638 715 801 898 1007 1130 1267 B2 378 417 460 509 563 625 694 771 857 954 1063 1186 1323 C2 176 195.5 217 241.5 168.5 199.5 209 247.5 265.5 264.0 268.5 280.0 298.5 E2 – – – – 200 200 250 250 300 400 500 600 700 39 Belt Driven Centrifugal Fans / RDH / Specifications RDH E0-0180/-0560 Specifications High performance centrifugal fan RDH E0 Double inlet belt drive. Lap jointed scroll of galvanised sheet steel assembled through a standing-seam. Multi-position feet and discharge flange as an option. Centrifugal impeller with 8 backward inclined blades made of fibreglass reinforced polyamide (sizes 0180/-0225) or with 11 backward inclined blades made of sheet steel, welded and coated, balanced in according to ISO 1940. Throat plate inclined to blade trasling edge. Noise tested, maintenance free, self aligning radial insert ball bearings, mounted in pressed steel housing/strut assemblies with rubber interliners. Performance data in according to DIN 24166 tolerance class 2 (sizes 0180/-0315) tolerance class 1 (sizes 0355/-0560). Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fittings / Accessories • • • • • • • • • • • • • • • 40 Multi-Position feet Discharge flange Discharge flex with flexible sleeve Inlet guard Discharge guard Shaft guard for free shaft end Matching flange Inspection door Drain plug R 1/8" Increase corrosion protection Volumeter Shaft made of stainless steel Nuts and bolts and fastening elements made of stainless steel Aluminium inlet cone Copper inlet cone 1/min Belt Driven Centrifugal Fans / RDH / Specifications RDH E2-0180/-0560 RDH R-0630/-0710 Specifications High performance centrifugal fan RDH E2 / RDH R Double inlet belt drive. Lap jointed scroll of galvanised sheet steel assembled through a standing-seam (sizes 0160/-0560) or by Pittsburgh lockforming (sizes 0630/-0710), discharge flange as an option. Rectangular side frame of galvanised steel. Centrifugal impeller with 8 backward inclined blades made of fibreglass reinforced polyamide (sizes 0180/-0225) or with 11 backward inclined blades made of sheet steel, welded and coated, balanced in according to ISO 1940. Throat plate inclined to blade trasling edge. Noise tested, maintenance free, self aligning radial insert ball bearings, mounted in pressed steel housing/strut assemblies with rubber interliners. Performance data in according to DIN 24166 tolerance class 2 (sizes 0180/-0315) or tolerance class 1 (sizes 0355/-0710). Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • • • • • • • • Multi-Position feet Discharge flange Discharge flex with flexible sleeve Inlet guard Discharge guard Shaft guard for free shaft end Matching flange Inspection door Drain plug R 1/8" Increase corrosion protection Volumeter Shaft made of stainless steel Nuts and bolts and fastening elements made of stainless steel Aluminium inlet cone Copper inlet cone, or equipped with a copper strip (from size 0630) 41 Belt Driven Centrifugal Fans / RDH / Specifications RDH E4-0200/-0560 RDH K-0630/-1000 RDH G2E4-0250/-0560 RDH G2K-0630/-1000 Specifications High performance centrifugal fan RDH E4 / RDH K Double inlet, belt drive. Lap jointed scroll of galvanised sheet steel assembled through a standing-seam (Sizes 0200/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange as an option. Welded heavy duty reinforced side frames, coated. Centrifugal impeller with 8 backward inclined blades made of fibreglass reinforced polyamide (sizes 0200/-0225) or with 11 backward inclined blades made of sheet steel, welded and coated (sizes 0250/-1000), balanced in according to ISO 1940. Throat plate inclined to blade trasling edge. Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust pedestal, integrated, self aligning radial insert ball bearings fixed by eccentric clamp. Performance data in according to DIN 24166 tolerance class 2 (sizes 0200/-0315) or tolerance class 1 (sizes 0355/-1000). Twin fan arrangement Twin fan arrangement High performance centrifugal fanRDH G2E4/RDH G2K The two single fans RDH E4 or RDH K are fitted together to a robust assembly by means of 3 crossbars. Both impellers are fitted on a common shaft supported by 3 bearings.(sizes 0250/-0630) or the fans have separated shafts being connected by a flexible coupling (sizes 0710/-1000). Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fittings / Accessories • • • • • • • • • • • • • • • 42 Discharge flange Discharge flex with flexible sleeve Inlet guard Discharge guard Shaft guard for free shaft end Matching flange Inspection door Drain plug R 1/8" Reinforcing side frame hot dip galvanised Increase corrosion protection Volumeter Shaft made of stainless steel Nuts and bolts and fastening elements made of stainless steel Aluminium inlet cone Copper inlet cone, or equipped with a copper strip (as from size 0630) 1/min Belt Driven Centrifugal Fans / RDH / Specifications RDH E6-0315/-0560 RDH K1-0630/-0900 Specifications High performance centrifugal fan RDH E6 / RDH K1 Double inlet, belt drive. Lap jointed scroll of galvanised sheet steel assembled through a standing-seam or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange as an option. Welded heavy duty reinforced side frames, coated. Centrifugal impeller with 11 backward inclined blades made of sheet steel, welded and coated, balanced in according to ISO 1940. Throat plate inclined to blade trasling edge. Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust pedestal, integrated, self aligning radial insert ball bearings fixed by conical sleeve. Performance data in according to DIN 24166 tolerance class 2 (size 0315) or tolerance class 1 (sizes 0355/-1000). Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • • • • • • • • Discharge flange Discharge flex with flexible sleeve Inlet guard Discharge guard Shaft guard for free shaft end Matching flange Inspection door Drain plug R 1/8" Reinforcing side frame hot dip galvanised Increase corrosion protection Volumeter Shaft made of stainless steel Nuts and bolts and fastening elements made of stainless steel Aluminium inlet cone Copper inlet cone, or equipped with a copper strip (from size 0630) 43 Belt Driven Centrifugal Fans / RDH / Specifications RDH E7-0500/-0560 RDH K2-0630/-1000 Specifications High performance centrifugal fan RDH E7 / RDH K2 Double inlet belt drive. Lap jointed scroll of galvanised sheet steel assembled through a standing-seam (Sizes 0500/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), discharge flange as an option. Welded heavy duty reinforced side frames, coated. Centrifugal impeller with 11 backward inclined blades made of sheet steel, welded and coated, balanced in according to ISO 1940. Throat plate inclined to blade trasling edge. Size 0500 Monobloc pedestal cast iron bearings with relubrication nipple, mounted on a robust pedestal, integrated, self aligning radial insert ball bearings fixed by conical sleeve Sizes 0560 up to 0800 Split pedestal cast iron bearings with relubrication nipple, mounted on a robust pedestal, integrated self aligning double row bearings fixed by conical sleeve, lubricated with long life high performance grease. Sizes 0900 and 1000 Single-piece piller blocks with relubrication nipple, mounted on a robust pedestal, integrated double row, self aligning roller bearings fixed by conical sleeve, lubricated with long life high performance grease. Performance data in according to DIN 24166 tolerance class 1. Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase pF . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fittings / Accessories • • • • • • • • • • • • • • • • 44 Discharge flange Discharge flex with flexible sleeve Inlet guard Discharge guard Shaft guard for free shaft end Matching flange Inspection door Drain plug R 1/8" Reinforcing side frame hot dip galvanised Increase corrosion protection Volumeter Threaded hole for measurement of shock impulse (sizes 0560 up to 1000) Shaft made of stainless steel Nuts and bolts and fastening elements made of stainless steel Aluminium inlet cone Copper inlet cone, or equipped with a copper strip (from size 0630) 1/min Belt Driven Centrifugal Fans / RDH / Specifications RDH G2E7-0250/-0560 RDH G2K2-0630/-1000 Specifications Centrifugal twin fan RDH G2E7 / RDH G2K2 Double inlet belt drive. Lap jointed scroll of galvanised sheet steel assembled through a standing-seam (sizes 0250/-0560) or by Pittsburgh lockforming (sizes 0630/-1000), fitted together to a robust assembly by means of 3 crossbars, discharge flange as an option. Welded heavy duty reinforced side frames, coated. Both impellers, with 11 backward inclined blades made of sheet steel, welded and coated, are fitted on a common shaft supported by 3 bearings (sizes 0250/-0630) or the fans have separated shafts being connected by an elastic coupling (sizes 0710/-1000), balanced in according to ISO 1940. Throat plate inclined to blade trasling edge. Sizes 0250 up to 0630 Single piece cast iron block housing with relubrication nipple, mounted on a robust pedestal, integrated, maintenance free, self aligning radial insert ball bearings fixed by eccentric clamp. Sizes 0710 up to 1000 Split pedestal cast iron block housing with relubrication nipple, mounted on a robust pedestal, outside bearings: integrated self aligning double row roller bearings, fixed by conical tightening sleeve, lubricated with long life high performance grease. inside bearings: integrated single row ball bearings, fixed by eccentric clamp, lubricated with long life high performance grease. Performance data in according to DIN 24166 tolerance class 2 (sizes 0250/-0315) or to tolerance class 1 (Sizes 0355/-1000). Fan data Fan type . . . . . . . . . . . . . . . . . . . . . . Volume flow qV . . . . . . . . . . . . . . . . . . . . . . . . m³/h Total pressure increase p F . . . . . . . . . . . . . . . . . . . . . . . . Pa Static pressure psF . . . . . . . . . . . . . . . . . . . . . . . . Pa Air density at fan inlet r1 . . . . . . . . . . . . . . . . . . . . . . . . kg/m³ Air medium temperature t . . . . . . . . . . . . . . . . . . . . . . . . °C Shaft power Pa . . . . . . . . . . . . . . . . . . . . . . . . kW Efficiency (ha) . . . . . . . . . . . . . . . . . . . . . . . . Speed N Sound power level (A weighted) LWA . . . . . . . . . . . . . . . . . . . . . . . . dB Weight m kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/min Fittings / Accessories • • • • • • • • • • • • • • • • Discharge flange Discharge flex with flexible sleeve Inlet guard Discharge guard Shaft guard for free shaft end Matching flange Inspection door Drain plug R 1/8" Reinforcing side frame hot dip galvanised Increase corrosion protection Volumeter Threaded hole for measurement of shock impulse (sizes 0560 up to 1000) Shaft made of stainless steel Nuts and bolts and fastening elements made of stainless steel Aluminium inlet cone Copper inlet cone, or equipped with a copper strip (from size 0630) 45 Fittings / Accessories [1] Mounting feet [2] Discharge flange [3] Discharge flex [4] Inlet guard [5] Discharge guard [6] Shaft guard [7] Mounting flange [8] Inspection door [9] Drain plug A extended corrosion protection A ATEX-Execution (RZR) A Impellerblades continuosly welded (RZR) A Casing continuosly welden-inside (RZR) A Casing continuosly welden- inside/outside (RZR) A Split casing (RZR 13/19) A Shaft from stainless steel A Nuts and bolts from stainless steel A Thread for impuls sensor fitting A Volumeter (RDH / RZR) A Copper inlet cone A Aluminium inlet cone (ADH / AT / RDH) A hot dip galvanised side frame (ADH / RDH) A relubricatable bearings (relubrication during operation, RZR) Fan set (ADH / AT / RDH on request) [10] Base frame [11] Pick-a-Back [12] Belt drive [13] Drive guard A Belt guard split horizontally A Access door on belt guard A Opening on belt guard for speed measuring device [14] Drive motor [15] Anti-vibration mounts 46 Gebhardt fan systems – the "completely carefree" package for installation fans with belt drive Fan systems with components tailored for each other, precisely assembled and adjusted, individually tested, delivered quickly and on time, allow for problem-free processing and ensure long and reliable operation. Size has its price so we build as small as possible Where required, we deliver our fan systems with safety equipment complying with DIN EN ISO 13857 for safe operation! A Optimised base frame lengths, tailored to the casing position and motor size and small system construction heights save valuable space in the air conditioning unit A Various casing and drive positions allow for individual adjustment to the most diverse applications A Optimised flat belt drives allow for efficient operation with a high level of convenience e.g. Belt guard A also as segmented design A also with inspection hole A also with rotation speed measurement opening. Fan set diversity Version Description Pick-A-Back for sizes 0200/-0355 Pick-A-Back for sizes 0400/-1000 Compact base frame Integrated compact base frame for sizes up to 0500. Base Frame, CC-profile Base frames made from CC-profiles with length optimation. Base Frame, U-profile Heavy duty base frame made from U-profiles, welded and painted, from size 0800 upward. Figure 47 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Drain Plug If the fan is installed outside, or if conveying a medium containing humidty, condensation of water may accumulate inside the fan scroll. For extraction of this water a condense water drain has to be installed at the lowest point of the scroll. The drain will be provided with a thread for connecting it to a piping. At order please indicate the required casing position. Connecting thread / hole A ADH / RDH = female thread R 1/8" A AT = drain hole A RZR 0200/-1000 = male thread R 1/2" A RZR 1120/-1600 = male thread R 1" Dimensions R R Inspection Door For the purposes of maintenance and cleaning there is an opening, which can be securely closed by means of an access door, in the fan casing. As it can only be opened with a tool, the access door complies with safety and accident prevention regulations. Additional securing with locking bars can be supplied on request. The site and orientation of the inspection opening depends on the casing position. The position should be specified when ordering according to the following diagram: e.g. Access door, Pos. 2. Inspection Door Positions Pos.1 Pos.2 Pos.3 Pos.1 Pos.1 Pos.2 Pos.2 Pos.4 Pos.3 Pos.3 ADH / RDH RZR 0200/-1000 RZR 1120 RZR 1250/-1600 Dimensions in mm, subject to change. ADH ..0160/-0180 0200/-0280 0315/-0560 0630/-1000 – 48 RZR ..- RDH ..100 × 230 240 × 240 360 × 360 500 × 500 500 × 500 0180 0200/-0280 0315/-0560 0630/-1000 1120/-1400 100 × 230 240 × 240 360 × 360 500 × 500 500 × 500 – 0200 0225/-0315 0355/-1000 1120/-1600 160 × 160 210 × 210 310 × 310 500 × 500 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Corrosion Protection Systems Nicotra Gebhardt fans are treated with high quality corrosion protection as standard. Under extreme operating conditions, however, additional corrosion protection is advisable. ADH / AT / RDH Extended corrosion protection for series ADH, AT and RDH only available on request. RZR Depending on the use to which the fan is to be put and the degree of exposure to corrosion, we offer various anti-corrosion protection measures. Corrosion protection - Class S40 Degreasing, ironphosphating A Powder coating Layer thickness ≥40 μm, Colour RAL 7039 A Wet lacquering Layer thickness ≥40 μm (primer + lacquer finish), Colour RAL 7039 Corrosion protection - Class K90 Degreasing, ironphosphating A Powder coating Layer thickness ≥90 μm, Colour RAL 7039 A Wet lacquerinag Layer thickness ≥90 μm (primer + lacquer finish), Colour RAL 7039 Corrosion protection - Class P100 Degreasing, ironphosphating A Thermoplastic powder coating Layer thickness ≥100 μm, Colour RAL 7001 Continuously welded blades Impeller blades can be continuously welded in order to increase the corrosion resistance when conveying a humid or slightly aggressive medium. The continuous welding has no influence on the material resistance or on the max. tip speed. Continuously welded scroll The casing can be continuously welded in order to increase the corrosion resistance when conveying a humid or slightly aggressive medium. By continuous welding the casing is provided with additional impermeability. A GEH 01 - Casing inside continuously welded A GEH 02 - Casing inside and outside continuously welded 49 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Split Casing There may be a lot of reasons to choose a split casing, the advantages of split casings are: A smaller openings for fan chambers A easier refitting of fan A easier transport to site A easier access to impeller for cleaning and maintenance The joint face on the casing position runs horizontally above or under the fan axis (see drawing). The reinforced side frames are not divisible. The fan is supplied fully assembled. Dimensions in mm, subject to change. a c7 t5 h6 t8 t11 h4 t7 c8 w w RZR RZR a c7c8h4h6t5t7t8t11w 13-19-0500 709 822 950 957 783 410 13-19-0560 785 914 1061 1083 884 458 13-19-0630 872 1021 1188 1204 984 511 13-19-0710 9671143133113501100572 13-19-080010861280149815201245640 13-19-090012191439168617071386719 13-19-100013561568184718691509784 473 531 594 666 749 843 923 409 456 510 571 640 720 784 477 530 594 665 749 843 924 652 743 820 905 1035 1140 1230 Stainless Steel Shaft For applications where there is an increased risk of corrosion, an optional shaft made of stainless steel can be supplied. A ADH / AT / RDH Stainless steel 1.4301 / AISI 304 / XCrNi18-10 A RZR Stainless steel 1.4305 Stainless Steel Nuts and Bolts For applications where there is an increased risk of corrosion, the connecting elements of the fan can be ordered made of stainless steel. Impuls Sensor Thread A tapped hole M6 or M8 can be provided in the pedestal bearing cast housing for admission of sensors to measure the shock impulses. (The measuring connecting piece is not included in the scope of delivery). 50 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Volumeter pin With the flow measuring device it is possible to easily measure/monitor the flow rate after the fan is installed. A pressure tapping at a predetermined position on the inlet cone is provided whereby the differential pressure in relation to the static pressure is measured in front ofthe inlet cone in a static atmosphere. Permissible media temperature: +80 °C (RZR), +70 °C (RDH). qV = K × 2 — × pDü Measuring connector in inlet cone Hose pipe to connecting piece in the side wall Connecting piece (external diameter of 6mm) for the pressure measurement In order to calculate the flow rate, a calibrating factor "K" is required. This factor is determined by comparativemeasurement on a standard test rig. Standard-calibration faktor K Where fans are built into a plenum, the pressure difference between the static pressure in the inlet side plenum and the pressure on the inlet cone is to bemeasured. It must be ensured that the static pressureto be measured in front of the inlet cone is not tampered by dynamic pressure fractions. It is often recommended to arrange a ring of points on the wall facing the outlet side as illustrated in the sketch. When using the K‑factors specified below, a minimum clearance of 0.5×D between the inlet cone of the fan and the side wall of the plenum must be maintained. Indentations that obstruct the flow to the cone canlead to faults when measuring the flow rate. In the event that the differential pressure is fed via a pressure sensor, the signal can also be used for regulating purposes. pin Calibration factors A v olume flow qV [m³/h] A calibration factor K [m²s/h] A density of media r [kg/m³] A pressure difference at cone DpDü [Pa] Type Standard calibration factor K m²s/h IMV 13-0200 IMV 13-0225 IMV 13-0250 IMV 13-0280 IMV 13-0315 IMV 13-0355 IMV 13-0400 IMV 13-0450 IMV 13-0500 IMV 13-0560 IMV 13-0630 IMV 13-0710 IMV 13-0800 IMV 13-0900 IMV 13-1000 IMV 13-1120 IMV 13-1250 IMV 13-1400 IMV 13-1600 100 115 140 165 190 235 290 360 460 560 730 960 1180 1450 1850 2400 3000 3800 4700 Inlet Cones Inlet cone of copper or aluminium prevent the production of sparks during operation. These can be employed when spark protection is required, but ATEX is not mandatory. Hot Dip Galvanised Side Frame Fan Ranges ADH/RDH E4, E6, E7 or K, K1, K2 For applications where an increased corrosion protection is required the reinforcing side frames of the casing can be executed in hot dip galvanisation as an option. 51 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Relubrications Series RZR The lubrication unit IWN allows the fan bearings to be greased even when in operation. The lubrication tubes screwed into the bearing housing are lead out and fastened at the side wall of the fan. If desired, the lubrication tubes can be lead to the drive side of the fan. A IWN 01 - uses standard grease A IWN 11 - uses moisture resistant grease ADH / AT / RDH RZR For more details see "Technical Description" - "Bearings"! Series ADH / RDH The bearing housings of the fan ranges ADH / RDH E4, E6, E7 or K, K1, K2 and AT AR, TIC are equipped with directly fitted grease nipples. Mounting feet Feet made from galvanized steel, either mounted or loose, enable the fan to be installed with a 0, 90 and 270 orientation. Protection guards The fans are designed for installation in equipment and as standard are not equipped with protective guards. They should not be put into operation before all protective devices are fitted and connected! Protective measures must be carried out as set out in DIN EN ISO 12100 "Safety of machinery - Basic concepts, general principles for design". If the application of the fan allows free access to the inlet and discharge apertures, safety devices must be put in place on the fan in accordance with DIN EN ISO 13857! Suitable safety guards are available as an optional extra. Shaft Guards Contact guard for the free end of the shaft for double inlet centrifugal fans. Models in accordance with DIN EN ISO 13857, made of painted steel mesh. Flanges Made from galvanized or painted steel, to connect ducts and system components to the fan outlet side. Flexible Connections Connecting piece with elastic intermediate section for the vibration or impact-noise decoupled connection of the fan to the system or unit. Made out of two connecting flanges with elastic intermediate section. Temperature range / Application A Standard up to +80 °C A ATEX max. +60 °C 52 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories Anti Vibration Mounts AV mounts are designed to prevent noise and vibrations being transmitted through the base of the fan. AV mounts should be mounted beneath the fan base frame so the weight and spring deflections are evenly distributed. They should not be mounted symmetrically because a counter force is induced into the system by the pressure created by the working fan. It is difficult for the manufacturer to establish the position of the AV mounts to suit all types of application. Vibration and noise insulation can also be improved by ensuring that the fan is connected to its external environment by a flexible coupling. Fastening for CC-profile Rubber pads and buffers for both vibration and noise insulation at fan speeds above 1400 rpm or 850 rpm. Fastening for U-profile Rubber buffers for noise insulation only at fan speeds under 800 rpm or 1700 rpm. Spring diffusers with noise insulation layer and height adjustment, for both vibration and noise insulation at fan speeds above 400 rpm. Available AV mounts for different fans, see proSELECTA II. The AVM-mounts are supplied with the suitable mounting material for the base frame. Anti Vibration Rubber Pads E H ZBD ZBD A B C D E G H 21-6035A* 21-6065A* 21-5935A* 21-5950A* 21-6035C* 21-6065C* 21-5935C* 21-5950C* 60 60 90 90 45 45 70 70 35 35 50 50 30 30 45 45 20 20 32 32 5 6 9 9 M6 M6 M10 M10 * A = for U-profile, C = for CC-profile G D C A B Anti Vibration Rubber Buffers K E F H G ZBD ZBD A E F G H K 01-0405A* 03-0503A* 01-0504A* 03-0806A* 03-1007A 03-1510A* 02-2008A* 01-0405C* 03-0503C* 01-0504C* 03-0806C* 03-1007C* 03-1510C* 02-2008C* 20 25 25 40 50 75 100 25 15 20 30 34 50 40 16 11 11 21 26.5 39 44 M 6 M 6 M 6 M 8 M 10 M 12 M 16 M 6 M 6 M 6 M 8 M 10 M 12 M 16 6.5 6.5 6.5 9.5 10.5 12.5 16.5 A * A = for U-profile, C = for CC-profile 53 Belt Driven Centrifugal Fans / Fittings and Accessories Fittings / Accessories H E Anti Vibration Spring Diffusers ZBD ZBD A B C D ~E ~F G H 60-0101A* 60-0103A* 60-0105A* 60-0108A* 60-0112A* 60-0120A* 60-0130A* 60-0150A* 60-0101C* 60-0103C* 60-0105C* 60-0108C* 60-0112C* 60-0120C* 60-0130C* 60-0150C* 130 130 130 130 150 150 150 150 100 100 100 100 120 120 120 120 70 70 70 70 82 82 82 82 72 72 72 72 92 92 92 92 70-50 70-50 70-50 70-50 90-75 90-75 90-75 110-85 35 35 35 35 35 35 35 35 13 13 13 13 13 13 13 13 M10 M10 M10 M10 M12 M12 M12 M12 G * A = for U-profile, C = for CC-profile B A Anti Vibration Spring Diffusers ~60 M8 M8 ZBD ZBD SP-7701A* SP-7702A* SP-7703A* SP-7704A* SP-7705A* SP-7706A* SP-7707A* SP-7701C* SP-7702C* SP-7703C* SP-7704C* SP-7705C* SP-7706C* SP-7707C* 45 * A = for U-profile, C = for CC-profile 11 95 70 ~106 M10 50 Anti Vibration Spring Diffusers ZBD ZBD SP-7501A* SP-7502A* SP-7503A* SP-7504A* SP-7505A* SP-7506A* SP-7507A* SP-7508A* SP-7501C* SP-7502C* SP-7503C* SP-7504C* SP-7505C* SP-7506C* SP-7507C* SP-7508C* * A = for U-profile, C = for CC-profile 120 150 Anti Vibration Spring Diffusers E H ZBD ZBD E H kg 80-W603A* 80-W605A* 80-W608A* 80-W612A* 80-W616A* 80-W603C* 80-W605C* 80-W608C* 80-W612C* 80-W616C* 68-101 76-101 86-105 84-104 92-105 M 16 M 16 M 16 M 16 M 24 8.3 8.6 9.0 9.3 9.7 14 200 * A = for U-profile, C = for CC-profile 240 270 54 Belt Driven Centrifugal Fans / Fan Set Fan Sets Base Frame with Belt Tensioning Device G2Z-component size 0200/-0500 (only RZR 11/19) This compact base frame with integrated motor tensioning slider provides optimum compactness and easiest handling. A The base frame made of galvanized sheet steel is screwed directly onto the fan (without any casing feet) – the result being the low overall height of the system. A The overall length depending on the casing position and size of the motor is a further factor influencing the optimum compactness. A The integrated tensioning slider considerably simplifies re-adjustment of the belt drive during maintenance and service work. G1Z-component size 0400/-0710 The base frames up to motor size 180 are manufactured from galvanized CC-profiles. The anti-vibration mounts in the CC-profile provide infinitely variable adjustment. From motor size 200 the base frames are of U-profile, welded and painted. Fitted motor tensioning tracks that allow the motor to be shifted longitudinally, allow for the simple adjustment of the belt tension. G1Z-component size 0800/-1600 Base frame of stable U-profiles, welded and painted, with holes for attaching the antivibration mounts. Fitted motor tensioning tracks that allow the motor to be shifted longitudinally, allow for the simple adjustment of the belt tension. Equipment A FKS hot-dip galvanized for U-profile base frame Pick-A-Back This allows the motor to be fixed directly onto the fan casing, where space around the fan is limited. One side of the pick-a-back is fixed to the casing so that it swivels, while the other is supported on a spindle. Thus the pick-a-back becomes adjustable to leave room for tensioning the drive belt. The various motor arrangements and casing positions are shown in the drawings. The accompanying tables also show the maximum permissible motor sizes. When using a pick-a-back arrangement and fitting anti vibration mounts (AVM) an additional base frame for fitting the AVM may be required depending on the position of the centre of gravity of the whole fan set. 55 Belt Driven Centrifugal Fans / Fan Set Fan Sets Belt Drive Wedge Belts High performance narrow V-belts in accordance with DIN 7753 are temperature stable up to +80 °C, resistant to mineral oils and electrostatically conductive. The belt pulleys are made of high quality cast iron and, depending on the peripheral velocity and number of grooves, are statically (G 16) or dynamically (G 6.3) balanced. They are fastened to the shaft of the motor or fan by means of a clamping bush. Flat Belts The flat belt drives employed are made using the most modern technology and materials. They are the centrepiece of highly developed, powerful belt drives. This modern flat belt drive has distinct advantages over traditionally employed V-belt drives and exceeds it in efficiency, quiet running and economy. Overview of the advantages: A higher efficiency A longer service life A quieter running A easy to install A low maintenance A no wear on the belt - so it is possible to dispense with the 2nd filter stage in the air conditioning unit (in accordance with VDI 6022) Belt Guard Totally enclosed belt guards are made from galvanised sheet steel in accordance with DIN DIN EN ISO 13857. The front section can be removed for maintenance. If there is no standard belt guard available for the selected belt drive (see table), a suitable belt guard will be made as a welded construction and then coated. Features A belt guard split horizontally A access door on belt guard A opening on belt guard for speed measuring device u4 b8 ~b7 Dimensions in mm, subject to change. l3 a7 l4 ~u3 RBS a7max DWmax b8 b7 s5 u4 u3 l4 l3 01-....-01 01-....-02 01-....-03 01-....-04 01-....-05 01-....-06 01-....-07 01-....-08 01-....-09 01-....-10 01-....-11 01-....-12 01-....-13 01-....-14 01-....-15 01-....-16 01-....-17 01-....-18 01-....-19 250 300 350 400 450 500 600 700 800 900 450 500 600 700 800 900 1000 1100 1200 90 90 160 160 160 160 160 125 125 125 250 250 250 315 315 315 315 315 315 194 194 264 264 264 264 264 264 264 264 344 344 344 484 484 484 484 484 484 159 159 229 229 229 229 229 229 229 229 304 304 304 444 444 444 444 444 444 97 97 132 132 132 132 132 132 132 132 172 172 172 242 242 242 242 242 242 72 72 72 72 72 72 72 72 72 72 122 122 122 122 122 122 122 122 122 69 69 69 69 69 69 69 69 69 69 119 119 119 119 119 119 119 119 119 444 494 614 664 714 764 864 964 1064 1164 794 844 944 1184 1284 1384 1484 1584 1684 404 454 574 624 674 724 824 924 1024 1124 754 804 904 1144 1244 1344 1444 1544 1644 ....Spaceholder for fansize 56 DWmaxDiameter of the biggest pulley a7maxMaximum axle centre distance Belt Driven Centrifugal Fans / Fan Set RZR 11-0200/-0500 Fan set arrangement with base frame Dimensions in mm, subject to change. RD 0 G L90 L90 L0 H0 H0 H90 L0 RD 90 G G0 G90 G0 LG LG 180 G LG 270 G G90 RD RD 180 G L270 RD 270 G L270 L180 H180 H180 H270 L180 P180 H90 LG 90 G G270 G180 H270 LG 0 G G180 G270 P180 G2Z L2 X2 X2 RZRRZR 2 2 2 2 G0 G90 G180G270H0 H90 H180H270 11-19- 0200 11-19- 0225 11-19- 0250 11-19- 0280 11-19- 0315 11-19- 0355 11-0400 11-0450 11-0500 625 650 880 650 358 680 710 925 710 404 705 730 974 730 440 725 755 1031 755 489 750 785 1094 785 542 845 885 1207 885 603 990 970 1350 970 671 103010101440 910755 1070105015301050827 RZRRZR 2 2 2 2 L0 L90 L180L270 11-19- 0200 11-19- 0225 11-19- 0250 11-19- 0280 11-19- 0315 11-19- 0355 11-0400 11-0450 11-0500 745 740 880 740 100 793 792 925 792 100 843 829 974 829 100 893 876 1031 876 100 952 931 1094 931 100 1087109012071060100 1219112013501120120 1315120314401203120 1400127915301279120 L2 408 467 510 569 623 689 773 868 956 356 401 438 485 537 601 667 750 821 386 431 477 531 597 670 749 840 929 P180X2 Motor Base frame ~ kg max. 396 423 450 482 520 552 587 646 700 132 6 132 7 132 7.5 132 8 132 9 16010 18011 18012 18014 286 322 356 395 438 487 546 612 680 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 57 Belt Driven Centrifugal Fans / Fan Set RZR 11-0400/-0710 Fan set arrangement with base frame Dimensions in mm, subject to change. G3 G180 P1 RD 270 G H180 H180 P3 G90 RD RD 180 G H270 LG 270 G G0 H270 P2 G90 G270 P4 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 P4 G3 G3 H0 G3 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 RZR 2 2 2 2 G0 G90 G180G270 G3 for motor size 63-7180-90100-132160-180 200-225 250-280 11-0400 11-0450 11-0500 11-0560 11-0630 11-0710 11-0710-U 1240130016501240 1300135017401298 1434140517721405 1558150819081508 1600157420061574 1708168021451680 1700170021151700 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC – 82-CC 82-CC – 82-CC82-CC ––– RZR H0H90 H180 H270 L2P1P2P3P4X2 Motor Base frame ~ kg max. CC 80-U100-U 11-0400 11-0450 11-0500 11-0560 11-0630 11-0710 11-0710-U 671 773 667 749 120 755 868 750 840 120 827 956 821 929 120 921 1071 914 1041 150 1028119510211168150 1152134111431316180 1152134111431316180 22531 3 3 22532 3 3 2253360– 2253463– 2253568– 18037 – – 250– 94 145 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 58 X2 275 320 348 384 432 479 – 355 408 452 502 566 625 – 669 275 718 320 766 348 851 384 915432 1014479 – – 3 Dimensions on request 550 614 682 759 846 943 943 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC – 80-U 3– 80-U 3– 80-U 3– 80-U 3– 80-U 3– – – 100-U 120-U 3 Belt Driven Centrifugal Fans / Fan Set RZR 12-0200/-0710 Fan set arrangement with base frame Dimensions in mm, subject to change. G0 RD RD 180 G G3 G180 H180 H180 P3 P1 RD 270 G H270 LG 270 G G90 H270 P2 G90 G270 P4 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 G3 G3 G3 H0 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) P4 G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 RZR 2 2 2 2 G0 G90 G180G270 G3 for motor size 63-71 80-90 100-132160-180200-225250-280 12-0200 12-0225 12-0250 12-0280 12-0315 12-0355 12-0400 12-0450 12-0500 12-0560 12-0630 12-0710 12-0710-U 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1430131216551312 1522138817401388 1610146018301460 1736156119581561 1865167020781670 2008178422351784 2035184022351840 – – –––– – – –––– – – –––– – – –––– – – –––– – – –––– 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 82-CC 80-U 3– – 82-CC 82-CC 82-CC 80-U 3– – 82-CC 82-CC82-CC– – ––– – 100-U 120-U 3 RZR H0 H90 H180H270L2 X2 Motor Base frame ~ kg max. CC 80-U100-U 12-0200 12-0225 12-0250 12-0280 12-0315 12-0355 12-0400 12-0450 12-0500 12-0560 12-0630 12-0710 12-0710-U 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 669 769 669 750 120 753 865 753 841 120 825 955 825 931 120 920 1067 920 1046 150 1027119510271173150 1152134111521324180 1152134111521324180 4 4 4 4 4 4 550 614 682 759 846 943 – 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 22531 3 3 22532 3 3 2253360– 2253463– 2253568– 18037 – – 250– 94 155 2T he base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 3 Dimensions on request 4 The RZR 12-0200 to 0355 can only be supplied as standard basic models. 59 Belt Driven Centrifugal Fans / Fan Set RZR 13-0400/-1000 RZR 18-0400/-1000 Fan set arrangement with base frame Dimensions in mm, subject to change. G3 G180 G270 P4 P1 RD 270 G H180 H180 P3 G90 RD RD 180 G H270 LG 270 G G0 H270 P2 G90 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 G3 G3 G3 H0 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) P4 G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 G0G90G180G270 G3 for motor size CC2U CC2U CC2U CC2U 63-71 80-90 100-132160-180200-225250-280 RZRRZR 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 0400 0450 0500 0560 0630 0710 0800 0900 1000 RZR RZR 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 0400 0450 0500 0560 0630 0710 0800 0900 1000 1240– 1300– 1650– 1240– 1300– 1350– 1740– 1298– 1411– 1411– 1772– 1411– 1468– 1468– 1908– 1468– 1564– 1564– 2006– 1564– 16601700 16601700 21452115 16601700 –2300 –2300 –2885 –2300 –2410 –2410 –3052 –2410 –2505 –2505 –3180 –2505 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC82-CC100-U120-U 3 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U H0H90 H180 H270 L2P1P2P3P4X2 Motor Base frame ~ kg max. CC80-U100-U120-U 671 775 671 775 170 755 868 755 868 170 827 957 827 957 170 921 1083 921 1083 210 1028120410281204210 1152135011521350240 1290152012901520250 1448170714481707260 1577186915771869260 22531 3 3 3 22532 3 3 3 225 3360 – – 225 3463 – – 225 3568 – – 250 37 94 155– 250 – 6798155 280 – 72 105165 280 – 77 111165 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 60 X2 290 316 345 382 410 464 518 570 620 290 316 345 382 410 464 518 570 620 669 290 718 316 766 345 851 382 915410 1014464 1155518 1276570 1317620 3 Dimensions on request 550 614 682 759 846 943 1048 1179 1316 Belt Driven Centrifugal Fans / Fan Set RZR 11-0800/-1000 RZR 15-0400/-1000 RZR 19-0400/-1000 Fan set arrangement with base frame Dimensions in mm, subject to change. G3 G180 G270 P4 P1 RD 270 G H180 H180 P3 G90 RD RD 180 G H270 LG 270 G G0 H270 P2 G90 G3 H0 P1 G3 LG H90 RD 90 G G180 P3 G3 G3 G3 H0 P2 G0 LG 180 G G3 RD 0 G G1Z (CC) P4 G270 G3 LG 90 G H90 LG 0 G G1Z (U) L2 X2 Anti-vibration mounts are supplied with AV brackets included. X2 G0G90G180G270 G3 for motor size CC2U CC2U CC2U CC2U 63-71 80-90 100-132160-180200-225250-280 RZR RZRRZR 15-19- 15-19- 15-19- 15-19- 15-19- 15-19- 11-15-19- 11-15-19- 11-15-19- 0400 0450 0500 0560 0630 0710 0800 0900 1000 RZR RZRRZR 15-19- 15-19- 15-19- 15-19- 15-19- 15-19- 11-15-19- 11-15-19- 11-15-19- X2 0400 0450 0500 0560 0630 0710 0800 0900 1000 1240– 1300– 1650– 1240– 1300– 1350– 1740– 1298– 1411– 1411– 1772– 1411– 1468– 1468– 1908– 1468– 1564– 1564– 2006– 1564– 16601700 16601700 21452115 16601700 –2300 –2300 –2885 –2300 –2410 –2410 –3052 –2410 –2505 –2505 –3180 –2505 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC 82-CC 80-U 3– 82-CC 82-CC82-CC100-U120-U 3 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U 80-U 80-U80-U100-U120-U H0H90 H180 H270 L2P1P2P3P4X2 Motor Base frame ~ kg max. CC80-U100-U120-U 671 775 671 775 170 755 868 755 868 170 827 957 827 957 170 921 1083 921 1083 210 1028120410281204210 1152135011521350240 1290152012901520250 1444170714441707260 1573186915731869260 22531 3 3 3 22532 3 3 3 225 3360 – – 225 3463 – – 225 3568 – – 250 37 94 155– 250 – 6798155 280 – 72 105165 280 – 77 111165 2 The base frame length has been determined with the always largest admitted motor size. With smaller motors the frame length will be reduced. For accurate dimensions use proSELECTA II or on request. 290 316 345 382 410 464 518 570 620 290 316 345 382 410 464 518 570 620 669 290 718 316 766 345 851 382 915410 1014464 1155518 1276570 1317620 550 614 682 759 846 943 1048 1179 1316 3 Dimensions on request 61 Belt Driven Centrifugal Fans / Fan Set AT 7/7-18/18 Fan set arrangement with Pick-A-Back Using these specially designed motor brackets, the motor can be fixed, Pick-A-Back, directly on the scroll of the S-version fans. When the motor must be held on the fan side-frames, the customer will need providing an appropriate slide or bracket, to connect it to the fixing holes on the standard frames. Motor positions Version 1 Version 2 0° 90° 180° 270° Permissible Motor Power 62 Size AT Version 1 ArticleMax. permissible code motor power kW Version 2 ArticleMax. permissible code motor power kW 7/7 9/7 9/9 10/8 10/10 12/9 12/12 15/11 15/15 18/13 18/18 6873030.75 6873030.75 6873080.75 6873120.75 6873140.75 6873180.75 6873200.75 6873350.75 6873380.75 6873460.75 6873480.75 687940– 6879401.1 6879411.1 6879421.5 6879431.5 6879442.2 6879452.2 6875463.0 6879473.0 6879483.0 6879493.0 Belt Driven Centrifugal Fans / Fan Set RZR 11-0200/-0710 RZR 19-0200/-0355 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. LG 90/1 LG 0/1 H15 H17 RD 0/1 RD 90/2 H16 H16 LG 90/2 LG 0/3 H16 LG LG 180/2 H16 RD RD 180/2 LG 270/3 H15 RD 270/3 H15 H16 RD 180/3 H15 H15 H17 LG 180/3 LG 180/1 RD 0/3 H16 RD 180/1 H17 H17 RD 90/1 H15 RD 270/2 LG 270/2 H17 H17 X1 L1 RZRRZR 1 ~ H15 1 ~ H16 1 ~ H17 11-19- 0200 11-19- 0225 11-19- 0250 11-19- 0280 11-19- 0315 11-19- 0355 11-0400 11-0450 11-0500 11-0560 11-0630 11-0710 650 720 680 100 700 760 720 100 750 850 810 100 860 930 890 100 880 970 960 100 96010801070100 128012901280120 133014301380120 136014701560120 151016301740150 166018001820150 181019602010180 L1 X1 Motor max. Weight ~ kg 286 322 356 395 438 487 546 612 680 756 843 940 901 1002 1002 1123 1123 1123 132 8 132 8 132 8 13211 16012 16017 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 63 Belt Driven Centrifugal Fans / Fan Set RZR 12-0200/-0710 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. H15 H15 LG 90/1 RD 0/3 H16 LG 90/2 RD 90/1 H17 RD 0/1 LG 0/3 H16 LG LG 180/2 H16 RD 90/2 H16 RD RD 180/2 LG 270/3 H15 RD 270/3 H15 H16 RD 180/3 H15 H15 H17 LG 180/3 LG 180/1 H16 LG 0/1 RD 180/1 H17 H17 RD 270/2 LG 270/2 H17 H17 X1 L1 RZR 1 ~ H15 1 ~ H16 1 ~ H17 12-0200 12-0225 12-0250 12-0280 12-0315 12-0355 12-0400 12-0450 12-0500 12-0560 12-0630 12-0710 670 670 690 100 710 730 780 100 850 840 860 100 880 920 930 100 950 950 1030 100 108010901130100 119012901280120 133014301390120 136014701560120 150016201630150 165017901810150 180019502000180 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 64 ~ L1 X1 Motor max. Weight ~ kg 286 322 356 395 438 487 546 612 680 756 843 940 90 1 100 1 100 2 112 2 112 3 112 3 132 7 132 7 132 8 13211 16012 16017 Belt Driven Centrifugal Fans / Fan Set RZR 13-0400/-1000 RZR 18-0400/-1000 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. RD 90/1 H16 H16 LG 90/1 LG 270/3 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 13-18- 0400 0450 0500 0560 0630 0710 0800 0900 1000 H17 RD 270/3 L1 1 ~ H15 RZRRZR H15 H15 X1 RD RD 180/2 H17 LG LG 180/2 1 ~ H16 1 ~ H17 ~ L1 128013001300170 132014301380170 135015601550170 153017001730210 164018701820210 180019702010240 197021502150250 215024002350260 223026302550260 X1 Motor max. Weight ~ kg 548 612 683 759 845 942 1053 1179 1317 13210 13211 13212 16015 16016 16023 16030 16033 16036 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 65 Belt Driven Centrifugal Fans / Fan Set RZR 11-0800/-1000 RZR 15-0400/-1000 RZR 19-0400/-1000 Fan set arrangement with Pick-A-Back Dimensions in mm, subject to change. RD 90/1 H16 H16 LG 90/1 LG 270/3 1 ~ H15 0400 0450 0500 0560 0630 0710 0800 0900 1000 1 ~ H16 1 ~ H17 ~ L1 128013001300170 132014301380170 135015601550170 153017001730210 164018701820210 180019702010240 197021502150250 215024002350260 223026302550260 1 This dimensions have been calculated with the largestappropriate applicable motor in mind. 66 H17 RD 270/3 L1 RZRRZRRZR 15-19- 15-19- 15-19- 15-19- 15-19- 15-19- 11-15-19- 11-15-19- 11-15-19- H15 H15 X1 RD RD 180/2 H17 LG LG 180/2 X1 Motor max. Weight ~ kg 548 612 683 759 845 942 1053 1179 1317 13210 13211 13212 16015 16016 16023 16030 16033 16036 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. Pulley-Diameter, Bearings Life Expectency As a principle, the fans are only equipped with noise tested precision bearings designed for a nominal bearing life time (L10h acc. to DIN ISO 281-1) of 40,000 operating hours. In order to not exceed the admitted bearing loads there are minimum pulley diameters defined to be respected when sizing the belt drive. The minimum pulley diameters indicated are to be applied for belt drives selected according to the state of the art and tensioned according to the prescriptions. For flat belt drives the minimum pulley diameters are to be increased of 40 % to the indicated figure! A correct design of a belt drive may be achieved with our selection software where all relevant parameters will be kept automatically. For correct design of a belt drive made by external means, dimensioning and the application of the tensioning forces have to made in full respect of all specification data indicated. Wedge Belts LT / LT = Shaft Centres b = Defection of belt in mm under test force Fp Fp = Test force N as prescribed by Nicotra Gebhardt-Document LT 2 LT / Belt Tensioning The correct tension is achieved when the test force Fp results in a deflection of 16 mm / metre of span. b F 2 p Flat Belts ε* LMu = Measuring Marks 1 before Tensioning LMg = Measuring Marks 1 After Tensioning e* = Stretching Values as specified by Nicotra Gebhardt-Document L Mg L Mu Belt Tensioning The correct belt tension is achieved when the measuring marks LMu have increased by the stretching value e*. This should be carried out in two stages to prevent overstressing of the bearing. Wedge- and Flat Belts = = A further simple method for setting or checking the correct belt tension is via the static frequency of the drive belt. Here the flat or V-belt is set to oscillate freely through striking it whilst stationary. These vibrations are measured using an electronic measuring unit (e.g. a belt tension gauge). The vibration frequency in Hz must then be set to the specified value (documentation / nameplate). 1 = Measuring point Detailed instruction on tensioning are included within the operating and maintenance manuals. 67 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for ADH Fan size 160 180 200 225 250 280 315 355 400 450 500 560 630 710 800 900 1000 68 Fan model E0 / E2 G2E0 / E2 E0 / E2 G2E0 / E2 E0 / E2 / E4 G2E0 / E2 E0 / E2 / E4 G2E0 / E2 E0 / E2 E4 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E2 G2E4 G2E7 L/R K K1 K2 G2R G2K G2K2 L/R K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K2 G2K G2K2 Nominal motor power in kW 2.2 63 63 63 63 71 71 80 80 80 80 3 71 71 80 80 95 95 112 100 112 90 100 95 100 112 100 112 4 125 140 140 160 150 112 132 125 5.5 7.5 11 15 140 180 160 18.5 22 224 100 118 160 140 212 150 112 224 112 140 180 224 160 250 160 224 250 160 190 212 224 125 280 180 224 236 224 280 160 180 212 224 140 280 180 212 250 280 160 190 250 212 250 315 160 180 250 300 190 224 180 315 250 315 180 212 250 300 190 160 250 180 212 236 160 224 250 280 180 160 250 180 200 224 180 224 280 355 212 180 212 180 236 200 224 280 200 224 224 212 180 212 180 224 212 236 200 224 250 200 224 224 280 236 200 236 200 280 200 250 180 280 224 224 280 224 224 280 224 224 280 190 224 280 140 90 140 100 180 112 180 118 125 90 180 125 140 112 200 140 180 100 132 112 180 150 140 112 200 150 132 112 180 150 132 100 180 140 200 112 132 118 212 180 140 112 200 160 132 112 200 180 112 100 100 118 112 118 250 180 224 150 224 132 180 150 224 200 132 132 45 55 75 300 300 300 224 200 160 132 37 250 140 112 132 30 180 132 212 180 160 132 215 200 236 160 224 224 160 180 132 200 180 224 150 132 180 180 250 224 180 250 180 160 190 224 250 180 180 200 160 180 180 200 180 212 180 200 280 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for AT Fan size 7/7 9/7 9/9 10/8 10/10 12/9 12/12 15/11 15/15 18/13 18/18 20/15 20/20 22/15 22/22 25/20 25/25 28/20 28/28 30/20 30/28 Fan model S / SC G2L / SC2 S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C S / SC AR G2L / SC2 G2C G3C TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 TIC G2C G2C-C2 G3C G3C-C2 Nominal motor power in kW 1.1 63 63 63 – 63 – – – 63 – 63 – 63 – – – 63 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 1.5 63 63 63 – 63 – 63 – 71 – 71 – 71 – 71 – 80 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 2.2 80 90 85 – 90 – 90 – 95 – 85 – 95 – 95 – 112 – 71 – 85 – – 90 – 80 – – 85 – 80 – – 80 – 80 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 3 112 118 112 80 125 71 125 85 132 – 112 80 132 – 125 85 140 – 90 – 95 – – 112 – 112 – – 112 – 100 – – 100 – 100 – – 100 – 95 – – 100 – 90 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 4 5.5 7.5 100 140 200 80 100 150 112 150 224 80 112 150 100 150 200 80 180 118 100 150 160 224 90 118 85 118 80 100 140 100 140 85 90 132 90 140 85 – 132 95 132 85 – 132 – 125 – – 132 – 118 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 125 180 118 180 90 112 200 140 200 112 112 180 118 200 112 100 180 132 180 100 100 180 100 180 95 100 180 100 180 95 100 100 – – – – 100 – – – – 100 – – – – 100 – – – – 90 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – 180 11 15 160 236 118 118 224 180 190 280 140 140 200 200 160 236 150 118 224 180 180 250 132 118 250 140 250 112 112 250 132 224 112 112 140 112 – 112 – 132 112 – 112 – 132 112 – 112 – 132 112 – 112 – 118 112 – 112 – 112 112 – 112 – 100 112 – 112 – 100 112 – 112 – 100 100 – 100 – 100 100 – 100 – 200 160 224 200 280 160 160 224 224 190 280 160 140 200 160 – 150 – 200 150 – 140 – 200 160 – 140 – 200 150 – 140 – 160 140 – 132 – 150 140 – 132 – 150 132 – 132 – 140 132 – 125 – 140 132 – 125 – 140 125 – 125 – 224 200 280 250 – 200 – 280 224 – 200 – 280 224 – 200 – 280 224 – 200 – 224 200 – 200 – 224 200 – 180 – 200 180 – 180 – 200 180 – 160 – 200 180 – 180 – 200 180 – 160 – 18.5 22 30 37 45 55 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 200 224 150 180 190 224 250 150 180 190 224 224 150 180 190 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 224 224 150 180 190 212 224 150 180 190 224 224 150 180 190 212 224 150 180 190 224 224 250 280 – 280 – 250 – 250 – 280 – 250 – 280 – 250 – 250 – 224 – 250 224 – 224 – 250 224 – 200 – 250 224 – 224 – 250 224 – 200 – 69 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for RDH Fan size Fan model 0180 0200 0225 E0 / E2 E0 / E2 / E4 E0 / E2 / E4 E0 / E2 E4 G2E4 G2E7 E0 / E2 E4 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E0 / E2 G2E4 G2E7 E0 / E2 E4 E6 G2E4 G2E7 E0 / E2 E4 E6 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E4 G2E7 E0 / E2 E4 E6 E7 G2E2 G2E4 G2E7 R K K1 K2 G2K G2K2 R K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K1 K2 G2K G2K2 K K2 G2K G2K2 0250 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 70 Nominal motor power in kW 2.2 63 63 63 3 63 63 63 71 71 80 4 71 80 71 80 80 5.5 7.5 90 90 85 100 90 112 90 100 90 118 90 80 90 85 100 90 90 112 100 15 18.5 22 180 118 140 150 125 160 180 125 140 125 160 30 37 45 55 75 100 90 125 112 90 100 90 112 112 100 125 90 140 100 112 112 112 125 112 100 118 125 132 132 100 11 112 125 112 118 112 132 112 180 140 140 112 160 150 118 150 140 180 150 112 140 140 180 150 200 140 224 200 160 212 150 125 200 150 200 140 150 180 160 140 212 160 160 200 280 180 150 236 180 190 180 200 280 355 250 315 180 224 250 200 180 200 280 250 280 180 212 180 190 250 160 180 250 212 250 224 250 315 180 236 315 190 224 280 140 118 224 150 180 250 200 140 190 180 224 224 200 250 180 250 212 224 212 224 224 224 224 224 224 250 280 280 224 224 280 224 224 280 224 224 300 224 224 280 280 Belt Driven Centrifugal Fans / Fan Set Fan Sets Min. recommended Pulley Diameter for RZR Fan size Fan model 0200 Nominal motor power in kW 3 4 5.5 7.5 11 / 12 / 19 71 71 71 90 0225 11 / 12 / 19 71 71 80 100 0250 11 / 12 / 19 71 71 90 112 15 18.5 22 30 11 / 12 71 71 90 118 19 71 71 71 85 11 / 12 71 85 106 132 19 71 71 75 95 11 / 12 75 95 118 150 19 71 71 85 106 11 / 12 71 80 100 125 13 / 15 / 18 / 19 71 71 71 71 85 106 125 140 180 11 / 12 71 90 112 140 13 / 15 / 18 / 19 71 71 71 71 95 118 140 160 200 11 / 12 80 100 125 160 13 / 15 / 18 / 19 71 71 71 80 106 132 160 180 224 11 / 12 71 71 85 112 150 190 13 / 15 / 18 / 19 71 71 71 71 90 112 132 150 190 224 11 / 12 71 80 100 132 180 224 13 / 15 / 18 / 19 71 71 71 75 100 125 150 170 224 250 11 / 12 71 85 112 140 190 236 280 13 / 15 / 18 / 19 71 71 71 71 85 106 118 140 180 11 80 100 125 160 224 280 315 355 13 / 15 / 18 / 19 71 71 71 71 95 118 140 160 11 95 118 150 200 280 355 400 450 13 / 15 / 18 / 19 71 71 71 71 85 106 125 140 11 112 140 180 224 315 400 450 500 13 / 15 / 18 / 19 71 71 71 71 95 118 140 1120 13 – – – – 315 315 1250 13 – – – – 315 1400 13 – – – – 1600 13 – – – – 0280 0315 0355 0400 0450 0500 0560 0630 0710 0800 0900 1000 11 37 45 55 75 90 110 132 212 250 280 212 236 280 315 180 212 250 300 375 160 212 236 280 315 425 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 315 160 200 355 355 400 450 315 355 355 400 400 450 315 315 355 355 400 400 450 450 315 315 355 355 400 400 450 500 250 112 125 140 560 For flat-belt-drives the listed recommended pulley diameter mus be enlarged up to approx. 40 %. 71 Belt Driven Centrifugal FansBelt Driven Centrifugal Fans / Description Description General The high-performance centrifugal fans are the result of extensive and systematic development work. These technically first-rate products are distinguished by their high efficiency, the large pressure differences attainable and low noise levels. The sizes are geometrically scaled in accordance with the standard range R 20 and the nominal size stated is the external diameter of the impeller. Media The fans are suitable for handling air and other non aggressive gases from -20 °C up to +80 °C, resp. +100 °C. The ambient temperature at the drive motor must not exceed +40 °C. Protective installations The fans are designed for installation in equipment and as standard are not equipped with protective guards. They should not be put into operation before all protective devices are fitted and connected! Protective measures must be carried out as set out in DIN EN ISO 12100 "Safety of machinery - Basic concepts, general principles for design". If the application of the fan allows free access to the inlet and discharge apertures, safety devices must be put in place on the fan in accordance with DIN EN ISO 13857! Suitable safety guards are available as an optional extra. Shafts Shafts ADH / AT / RDH The fan shafts are manufacrured of ground, precisely rounded carbon steel C40. They are principally prepared without being stepped at both ends. The shafts of the RDH K1 and K2 ranges, size 1000 are machined on both ends for fitting a pulley. ADH / AT from size 12/9 / RDH The shafts are equipped with a keyway (open shape) at both ends and a key (type 2). AT 7/7 up to 10/10 The standard construction is the version with flats on shaft ends (type 1), it is also available the version with keyways (type 2). For corrosion protection the shafts are galvanised up to fan size 0560 and 30/28. From size 0630 and larger the shaft are covered, between bearing and hub, with a paint in order to ensure corrosion protection. The shaft ends are covered with a wax product easy to remove. Shafts RZR The shafts are manufacured of precisely rounded carbon steel C35, pared and polished. Up to size 1000 they are not stepped at the shaft end. For sizes 1120 up to 1600 the shafts are machined on both ends for fitting a pulley. The shafts are equipped with a keyway at both ends and a key executed according to DIN 6885-1. A Groove shape N2 (open) Sizes 0200 up to 1000 A Groove shape N1 Sizes 1120 up to 1600 The shafts are covered with a easily removable wax product for corrosion protection. Housig feet / Side frames ADH / AT / RDH For easier installation of the fan the mounting feet and reinforcing frames are provided with eye holes. 72 Belt Driven Centrifugal FansBelt Driven Centrifugal Fans / Description Description Bearings ADH / AT / RDH ADH E0 / ADH L ADH E2 / ADH R AT S / AT SC AT G2L / AT SC2 RDH E0 RDH E2 / RDH R Maintenance free, self aligning radial insert ball bearings, mounted in pressed steel housing/strut assemblies with rubber interliners. ADH E4 / ADH K AT AR / AT TIC / AT G2C RDH E4 / RDH K Monobloc pedestal cast iron pillow block bearings with relubrication nipple, mounted on a robust frame. Integrated, maintenance free self aligning radial ball bearings, fixed by eccentric clamp. ADH E6 / ADH K1 / ADH E7-0500 RDH E6 / RDH K1 / RDH E7-0500 Pilow block cast iron bearings with relubrication nipple, mounted on a robust frame. Integrated self aligning radial ball bearings, fixed by conical sleeve and locknut. ADH E7-0560; ADH K2-0630/-0800 AT G2C-C2 RDH E7-0560; RDH K2-0630/-0800 Split-type plummer block bearings with relubrication nipple, mounted on a robust frame, integrated self aligning double row ball-bearings fixed by conical sleeve, lubricated with long life high performance grease. ADH K2-0900-1000 RDH K2-0900-1000 RDH X1 RDH X2 Single piece plummer block housing, with grease nipple, mounted on robust pedestal, equipped with self aligning double row roller bearing, fixed to impeller shaft by a concentric shaft clamp, lubricated with long life high performance grease. Twin Fans The twin fans up to size 0630 are equipped with one single shaft and 3 bearings. From size 0710 the two separate fans are connected by an elastic coupling. For the models G2K2 the bearings from size 0710 and larger are – due to different loads – of a different execution inside compared to outside. 73 Belt Driven Centrifugal Fans / Description Description Bearings RZR RZR 11-0200/-1000; RZR 12-0200/-0710 (without lubricators) Radial insert ball bearings with spherical outer Ring mounted in pressed steel housing/strut assemblies with rubber interliners. RZR 11-0200/-0710; RZR 12-0200/-0710 (with relubricators) Radial insert ball bearings with spherical outer Ring mounted within cast iron housing, supported from the fan casing by tubular struts. Relubrication is effected via extended tubes and nipples. RZR 19-0200/-0355 (without lubricators) Radial insert ball bearings with spherical outer Ring mounted within cast iron housing, supported from the fan casing by tubular struts. RZR 19-0200/-0355 (with relubricators) Relubrication is effected via extended tubes and nipples. RZR 15-0400/-1000; RZR 19-0400/-1000 (without lubricators) Self aligning double row ball bearings secured by adapter sleeve, mounted within a cast iron housing. RZR 15-0400/-1000; RZR 19-0400/-1000 (with relubricators) Relubrication is effected via extended tubes and nipples. RZR 13-0400/-1600; RZR 18-0400/-1000 (without lubricators) Self aligning double row ball bearings within standard plummer blocks, mounted on robust pedestal. RZR 13-0400/-1600; RZR 18-0400/-1000 (with relubricators) Relubrication is effected via extended tubes and nipples. Lubricators for relubrication during operation The Bearings are charged with long life high performance grease. Relubrication is effected via extended tubes and nipples. See operating and maintenance instructions. A IWN 01 - Standard grease, Gadus S2 V100 3 A IWN 11 - Klüber-Staburags NBU12/300KP 74 Belt Driven Centrifugal Fans / Description Description Motors Standard motors of wellknown brands, type of protection IP55, thermal class F, are used. During commissioning and maintenance the detailed instructions provided by the motor manufacturer (type plate/motor operating instructions) must be followed, this also applies to the motor protection devices required onsite. The motors are equipped with PTC resistors/temperature sensors as standard. Motors with integrated frequency inverters may be supplied on request. EX-ATEX motors Fan sets of centrifugal fans according to Ex-ATEX execution are equipped with motors of the correspondent category. For frequency inverter operation the motors will be of pressure resistant execution. Speed regulation A suitable speed variation system is required for the optimum adjustment of the desired operating point. Our frequency converters are perfectly tuned for the operation of RZR centrifugal fans. The use of the newest power semi-conductors guarantees high efficiency and minimum motor noise thanks to the especially fine pulse pattern. See also the technical description "Performance". Electric connection Centrifugal fan systems are delivered ready for installation. The motor terminal box can be easily accessed. Electric installation must be carried out according to the applicable provisions in compliance with local regulations. A terminal board circuit diagram showing correct connection is enclosed with every motor. Attachment points on the side plates ADH/RDH ADH/RDH 0160/-0180 g m hh d p 0160 0180 a 281 310 b 291 326 c 205 229 d 141 157 e 119 131 f 172 195 g 140 153 h 30 30 m 92 92 n 121 141 p 67 81 r 155 175 s 101 115 ø 4 4 p s e hh b m r c n f ø a hh ADH/RDH 0200/-0250 g a h h z d 0200 0225 0250 a 341 379 416 0200 0225 0250 p 134 152 171 x u p e h h b m c n v r f ø m m s h h m s b 362 407 452.5 r 202 229 256 c 256 288 322 s 129 149 172 d 177 199 221 e 147 165 183.5 t 163 185 208 f 215 242 269 u 126 142 155 g 164 180 195 v 190 219 244 h 40 40 40 z 94 114 137 m 110 110 110 x 91 107 120 n 155 184 209 ø 4 4 4 t 75 Belt Driven Centrifugal Fans / Description Description Attachment points on the side plates ADH/RDH ADH/RDH 0280/-0315 ø g a h 0280 0315 d h a b c d e f g h 464 508 361 249 206 302 215 113 515 571 404 279 232 339 236 113 m 71 71 n p r s t u v ø 170 191 287 169 233 150 245 6.2 195 215 323 197 263 175 284 6.2 n u p e h b h c v r f Scroll dimensions are refered to the external surface of the back plate m h s t ADH/RDH 0355/-0450 g o h s h d h h u p e n m b c v r f ø a m h 0355 0400 0450 a 576 644 721 b 643 733 817.5 c 453 507 569 d 315 354 399 e 261 302 332.5 f 382 431 485 g 261 290 322 h 156 156 213 m 158 186 168 0355 0400 0450 n 197.5 220 245 o 197.5 230 256 p 241 275 311 r 364 411 466 s 204 243 271 t 295 336 379 u 158 186 168 v 295 346 350 ø 6.2 6.2 M10 Scroll dimensions are refered to the external surface of the back plate t ADH/RDH 0500 g o h w s h w d 0500 a 794 b 906 c 638 d 442 e 368 f 538 g 352 h 231 m 439 n 220 0500 o 281 p 349 r 519 s 280 t 423 u 207 v 400 k 354 w 181 ø M10 Scroll dimensions are refered to the external surface of the back plate u h u p e b h v c m k n r f ø a h h t ADH/RDH 0560/-0710 o h w s h w d u h u p e x b h v c m k n ø a r f g h z h 0560 0630 0710 a 886 993 1119 b 1016 1142 1295 c 715 801 898 d 496 559 634 e 413 463 530 f 603 679 765 g 390 434 485 h 235 235 265 m 490 553.5 626.5 n 245 260 267.5 o 310 353 393 0560 0630 0710 p 389 441 496 r 581 656 737 s 362 431 476 t 472 521 605 u 276 328 371 v 494 567 637 z 310 356 397 x 140 160 200 k 394 – – w 180 – – ø M10 M10 M10 Scroll dimensions are refered to the external surface of the back plate t Screw to be used to attach mounting feet 76 Size Type of screw 0160/-0250 0280/-0400 0450/-0710 Self-threading screw Self-threading screw Metric screw Thread AB 6.3 ISO 1478 AB 8 ISO 1478 M10 ISO 724 Belt Driven Centrifugal Fans / Description Description Operating limits ADH Permissible Permissible Permissible nominal fan speed bearing motor load power ADH kW 1/min N E0-0160 E2-0160 G2E0-0160 G2E2-0160 E0-0180 E2-0180 G2E0-0180 G2E2-0180 E0-0200 E2-0200 E4-0200 G2E0-0200 G2E2-0200 E0-0225 E2-0225 E4-0225 G2E0-0225 G2E2-0225 E0-0250 E2-0250 E4-0250 G2E0-0250 G2E2-0250 G2E4-0250 G2E7-0250 E0-0280 E2-0280 E4-0280 G2E0-0280 G2E2-0280 G2E4-0280 G2E7-0280 E0-0315 E2-0315 E4-0315 E6-0315 G2E0-0315 G2E2-0315 G2E4-0315 G2E7-0315 E0-0355 E2-0355 E4-0355 E6-0355 G2E0-0355 G2E2-0355 G2E4-0355 G2E7-0355 E0-0400 E2-0400 E4-0400 E6-0400 G2E0-0400 G2E2-0400 G2E4-0400 G2E7-0400 E0-0450 E2-0450 E4-0450 E6-0450 G2E0-0450 G2E2-0450 G2E4-0450 G2E7-0450 3 3 3 4 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 7.5 4 4 7.5 15 5.5 5.5 11 5.5 5.5 11 22 5.5 5.5 11 18.5 5.5 5.5 11 30 7.5 7.5 15 22 7.5 7.5 15 30 7.5 7.5 15 22 7.5 7.5 15 37 11 11 15 30 11 11 15 37 4200 4200 3400 3400 4000 4000 3200 3200 3800 3800 3800 2900 2900 3400 3400 3400 2600 2600 2800 2800 3000 2200 2200 2300 2800 2500 2500 2700 2000 2000 2200 2400 2100 2100 2400 2400 1600 1600 1900 2100 1800 1800 2000 2000 1500 1500 1700 1900 1600 1600 1800 1800 1200 1200 1400 1800 1400 1400 1500 1500 1000 1000 1200 1400 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 420 450 420 420 450 1250 530 530 660 530 530 660 1700 530 530 660 1050 530 530 660 2000 840 840 940 1450 840 840 940 2000 840 840 940 1450 840 840 940 2950 1180 1180 1320 1800 1180 1180 1320 2950 Permissible Fan media weight temperature °C kg ADH Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 5 6.6 10.5 14.5 6 7.8 12.6 17 7.1 9.1 12.6 15 20 8.5 10.7 14.5 18 24 10.5 13 18 22 29 38 44 14.2 18 24 30 39 50 59 18 22 29 30 38 48 60 73 23 29 41 42 49 63 84 98 31 38 52 53 66 82 108 133 42 50 66 67 90 107 135 159 E0-0500 E2-0500 E4-0500 E6-0500 E7-0500 G2E0-0500 G2E2-0500 G2E4-0500 G2E7-0500 E0-0560 E2-0560 E4-0560 E6-0560 E7-0560 G2E2-0560 G2E4-0560 G2E7-0560 L-0630 R-0630 K-0630 K1-0630 K2-0630 G2R-0630 G2K-0630 G2K2-0630 L-0710 R-0710 K-0710 K1-0710 K2-0710 G2K-0710 G2K2-0710 K-0800 K1-0800 K2-0800 G2K-0800 G2K2-0800 K-0900 K1-0900 K2-0900 G2K-0900 G2K2-0900 K-1000 K1-1000 K2-1000 G2K-1000 G2K2-1000 11 11 15 30 37 11 11 15 45 15 15 18.5 30 45 15 18.5 45 15 15 18.5 30 45 15 18.5 55 18.5 18.5 22 37 55 30 75 22 37 55 30 75 30 45 75 37 75 37 45 75 37 75 1200 1200 1300 1400 1400 900 900 1000 1400 1100 1100 1200 1300 1300 800 900 1200 900 900 1000 1100 1100 700 750 1000 750 750 850 900 900 700 800 750 800 800 600 700 650 700 700 500 600 600 600 650 450 500 1180 1180 1320 1800 2200 1180 1180 1320 4000 1450 1450 1760 2550 3700 1450 1760 4000 1450 1450 1760 2550 3700 1450 1760 4000 1800 1800 1900 3550 5800 3000 7000 1900 3550 5800 3000 7000 3000 3900 7000 3000 7000 3000 3900 7000 3000 7000 Permissible Fan media weight temperature °C kg -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 57 65 85 86 105 120 140 176 221 72 86 134 142 150 185 268 319 91 106 170 175 180 230 342 393 118 135 201 208 225 532 537 249 261 278 665 670 306 316 320 801 806 333 356 360 894 899 77 Belt Driven Centrifugal Fans / Description Description Operating limits AT Permissible Permissible Permissible nominal fan speed bearing motor load power AT kW 1/min N S-7/7 SC-7/7 G2L-7/7 SC2-7/7 S-9/7 SC-9/7 AR-9/7 G2L-9/7 SC2-9/7 G2C-9/7 S-9/9 SC-9/9 AR-9/9 G2L-9/9 SC2-9/9 G2C-9/9 S-10/8 SC-10/8 AR-10/8 G2L-10/8 SC2-10/8 G2C-10/8 S-10/10 SC-10/10 AR-10/10 G2L-10/10 SC2-10/10 G2C-10/10 S-12/9 SC-12/9 AR-12/9 G2L-12/9 SC2-12/9 G2C-12/9 G3C-12/9 S-12/12 SC-12/12 AR-12/12 G2L-12/12 SC2-12/12 G2C-12/12 G3C-12/12 S-15/11 SC-15/11 AR-15/11 G2L-15/11 SC2-15/11 G2C-15/11 G3C-15/11 S-15/15 SC-15/15 AR-15/15 G2L-15/15 SC2-15/15 G2C-15/15 G3C-15/15 78 3 3 3 3 3 3 7.5 3 3 7.5 3 3 7.5 3 3 7.5 3 3 7.5 3 3 7.5 4 4 7.5 3 3 7.5 5.5 5.5 11 5.5 5.5 11 11 5.5 5.5 11 5.5 5.5 11 11 5.5 5.5 11 5.5 5.5 11 15 5.5 5.5 11 5.5 5.5 11 15 2600 2600 2400 2600 2500 2500 2500 2400 2500 2500 2100 2100 2100 2000 2100 2100 2500 2500 2500 2100 2500 2500 2000 2000 2000 1800 2000 1700 2000 2000 2000 1800 2000 2000 2000 1500 1500 1500 1400 1500 1400 1400 2000 2000 2000 1400 2000 1500 1500 1200 1200 1200 1100 1200 950 1000 350 350 350 350 350 350 620 350 350 1000 350 350 620 350 350 1000 350 350 620 350 350 1000 350 350 620 350 350 1000 620 620 1000 620 620 1200 1200 620 620 1000 620 620 1200 1200 620 620 1000 620 620 1200 1600 620 620 1000 620 620 1200 1600 Permissible Fan media weight temperature °C -20 / +85 -20 / +85 -20 / +85 -20 / +85 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 kg 5 6 11.7 13.7 6.6 8.3 8.3 14.9 18 23.5 7.9 9.5 9.5 18.1 21.8 27 8.3 9.8 9.8 18.5 21.8 27 9.3 11 11 21.1 23.5 31 12.7 16 16 28.2 34.8 45.5 70 15.2 18.4 18.4 33.8 40.2 51 81 17.7 20.9 20.9 39.7 46.1 57.4 90 20.6 24.5 24.5 45.3 53.1 68 108 AT S-18/13 SC-18/13 AR-18/13 G2L-18/13 SC2-18/13 G2C-18/13 G3C-18/13 S-18/18 SC-18/18 AR-18/18 G2L-18/18 SC2-18/18 G2C-18/18 G3C-18/18 TIC-20/15 G2C-20/15 G2CC2-20/15 G3C-20/15 G3CC2-20/15 TIC-20/20 G2C-20/20 G2CC2-20/20 G3C-20/20 G3CC2-20/20 TIC-22/15 G2C-22/15 G2CC2-22/15 G3C-22/15 G3CC2-22/15 TIC-22/22 G2C-22/22 G2CC2-22/22 G3C-22/22 G3CC2-22/22 TIC-25/20 G2C-25/20 G2CC2-25/20 G3C-25/20 G3CC2-25/20 TIC-25/25 G2C-25/25 G2CC2-25/25 G3C-25/25 G3CC2-25/25 TIC-28/20 G2C-28/20 G2CC2-28/20 G3C-28/20 G3CC2-28/20 TIC-28/28 G2C-28/28 G2CC2-28/28 G3C-28/28 G3CC2-28/28 TIC-30/20 G2C-30/20 G2CC2-30/20 G3C-30/20 G3CC2-30/20 TIC-30/28 G2C-30/28 G2CC2-30/28 G3C-30/28 G3CC2-30/28 Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N Permissible Fan media weight temperature 7.5 7.5 15 7.5 7.5 15 15 7.5 7.5 15 7.5 7.5 15 15 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 45 18.5 45 15 18.5 55 18.5 55 18.5 18.5 55 18.5 55 18.5 18.5 55 18.5 55 18.5 18.5 55 18.5 55 18.5 18.5 55 18.5 55 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +85 -20 / +85 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 1200 1200 1200 1100 1200 1200 1000 1100 1100 1100 800 800 1000 700 1300 1300 1300 900 1100 1300 900 1200 700 800 1300 1300 1300 800 1000 1200 900 1000 600 800 1000 700 800 600 700 900 700 800 500 600 800 600 800 600 650 800 600 700 400 550 800 600 700 550 600 800 600 700 400 500 620 620 1200 620 620 1600 1600 620 620 1200 620 620 1600 1600 1200 1600 6500 1600 6500 1200 1600 6500 1600 6500 1200 1600 6500 1600 6500 1200 1600 6500 1600 6500 1600 1600 6500 1600 6500 1600 1600 6500 1600 6500 1600 1600 7000 1600 7000 1600 1600 7000 1600 7000 1600 1600 7000 1600 7000 1600 1600 7000 1600 7000 °C kg 27 33 33 57.8 69.8 91 118 32.5 38.2 38.2 70.5 81.9 106 137 71 137 144 315 319 78 150 158 355 359 73 141 148 340 347 82.5 165 173 425 438 93 195 202 432 436 105 202 210 480 484 120 210 218 474 478 127 235 244 539 543 131 245 253 505 509 138 302 310 577 581 Belt Driven Centrifugal Fans / Description Description Operating limits RDH Permissible Permissible Permissible nominal fan speed bearing motor load power RDH kW 1/min N E0-0180 E2-0180 E0-0200 E2-0200 E4-0200 E0-0225 E2-0225 E4-0225 E0-0250 E2-0250 E4-0250 G2E4-0250 G2E7-0250 E0-0280 E2-0280 E4-0280 G2E4-0280 G2E7-0280 E0-0315 E2-0315 E4-0315 E6-0315 G2E4-0315 G2E7-0315 E0-0355 E2-0355 E4-0355 E6-0355 G2E4-0355 G2E7-0355 E0-0400 E2-0400 E4-0400 E6-0400 G2E4-0400 G2E7-0400 E0-0450 E2-0450 E4-0450 E6-0450 G2E4-0450 G2E7-0450 E0-0500 E2-0500 E4-0500 E6-0500 E7-0500 G2E4-0500 G2E7-0500 E0-0560 E2-0560 E4-0560 E6-0560 E7-0560 G2E4-0560 G2E7-0560 R-0630 K-0630 K1-0630 K2-0630 G2K-0630 G2K2-0630 2.2 2.2 3 3 3 4 4 4 4 4 5.5 5.5 7.5 5.5 5.5 7.5 5.5 11 5.5 5.5 7.5 11 5.5 11 7.5 7.5 11 15 7.5 11 7.5 7.5 15 22 7.5 18.5 11 11 15 30 11 18.5 11 11 15 30 37 11 30 15 15 18.5 30 37 11 30 15 18.5 30 45 15 37 6800 6800 6000 6000 6800 5800 5800 6000 4600 4600 5400 2900 3500 4000 4000 4700 3000 3400 3500 3500 4100 4500 2200 3300 3300 3300 3800 4000 2000 2600 2700 2700 3100 3500 1600 2800 2500 2500 2800 3200 1400 2200 2100 2100 2350 2650 2800 1200 2200 1950 1950 2100 2400 2600 1100 1900 1600 1700 2000 2300 1000 1400 420 420 420 420 420 420 420 420 420 420 450 450 660 530 530 660 660 940 530 530 660 1050 660 1320 840 840 940 1450 940 1320 840 840 940 1450 940 1760 1180 1180 1320 1800 1320 1760 1180 1180 1320 1800 2200 1320 3000 1450 1450 1760 2550 3700 1760 3000 1450 1760 2550 3700 1760 3000 Permissible Fan media weight temperature °C kg RDH Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 5.3 7.1 6.6 8.5 11.8 7.8 9.9 13.6 13.3 15.7 21 46 49 17.8 21 28 61 65 21 25 32 34 70 79 29 34 46 47 104 109 36 42 57 58 126 144 50 57 73 75 160 176 62 70 90 92 110 197 235 79 92 141 148 153 301 336 119 173 180 185 370 408 R-0710 K-0710 K1-0710 K2-0710 G2K-0710 G2K2-0710 K-0800 K1-0800 K2-0800 G2K-0800 G2K2-0800 K-0900 K1-0900 K2-0900 G2K-0900 G2K2-0900 K-1000 K1-1000 K2-1000 G2K-1000 G2K2-1000 X1-1120 X2-1120 X1-1250 X2-1250 X1-1400 X2-1400 15 22 37 55 30 75 22 37 55 30 75 30 45 75 37 75 37 45 75 37 75 55 110 75 132 90 160 1300 1500 1700 2000 1400 1700 1200 1400 1650 1150 1400 1100 1250 1500 1000 1100 1000 1000 1300 800 800 900 1170 800 1050 720 930 1800 1900 3550 5800 3000 7000 1900 3550 5800 3000 7000 3000 3900 7000 3000 7000 3000 3900 7000 3000 7000 8000 8000 8000 10000 9000 12500 Permissible Fan media weight temperature °C kg -20 / +80 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 -20 / +100 165 220 240 250 580 586 270 297 305 747 753 343 355 375 883 889 415 430 450 1048 1054 610 890 950 1140 1370 1390 79 Belt Driven Centrifugal Fans / Description Description Operating limits RZR Permissible Permissible Permissible nominal fan speed bearing motor load power RZR kW 1/min N 11-0200 12-0200 19-0200 11-0225 12-0225 19-0225 11-0250 12-0250 19-0250 11-0280 12-0280 19-0280 11-0315 12-0315 19-0315 11-0355 12-0355 19-0355 11-0400 12-0400 15-0400 19-0400 18-0400 13-0400 11-0450 12-0450 15-0450 19-0450 18-0450 13-0450 11-0500 12-0500 15-0500 19-0500 18-0500 13-0500 11-0560 12-0560 15-0560 19-0560 18-0560 13-0560 11-0630 12-0630 15-0630 19-0630 18-0630 13-0630 11-0710 12-0710 15-0710 19-0710 18-0710 13-0710 11-0800 15-0800 19-0800 18-0800 13-0800 11-0900 15-0900 19-0900 80 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 11 7.5 7.5 11 7.5 7.5 11 7.5 7.5 30 30 30 30 7.5 7.5 30 30 30 30 7.5 7.5 30 30 30 30 15 15 37 37 37 37 15 15 37 37 37 37 18.5 18.5 55 55 55 55 22 55 55 55 55 22 75 75 7490 7490 7490 6640 6640 6640 5250 5250 5970 5235 5235 5300 4418 4418 4730 3200 3200 4187 3027 3027 3600 3600 3600 3600 2504 2504 3360 3360 3360 3360 2050 2050 2920 2920 2920 2920 2205 2205 2400 2400 2490 2490 1838 1838 1880 1880 2380 2380 1627 1627 2000 2000 2120 2120 1300 1470 1470 1700 1700 1000 1430 1430 480 480 480 500 500 500 540 540 540 630 630 850 660 660 910 720 720 950 1020 1020 1970 1970 1970 1970 1080 1080 2000 2000 2000 2000 1140 1140 2040 2040 2040 2040 1830 1830 2950 2950 2950 2950 1960 1960 3000 3000 3000 3000 2080 2080 4400 4400 4400 4400 2150 4500 4500 4500 4500 2180 6000 6000 Permissible Fan media weight temperature °C kg RZR Permissible Permissible Permissible nominal fan speed bearing motor load power kW 1/min N -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 11 12 13 13 15 16 15 17 17 20 23 23 24 27 28 33 36 39 43 49 61 66 70 75 54 60 73 82 83 92 65 72 94 105 105 116 103 109 125 136 140 151 124 132 149 162 167 180 177 194 201 225 230 254 250 250 280 289 319 358 358 396 18-0900 13-0900 11-1000 15-1000 19-1000 18-1000 13-1000 13-1120 13-1250 13-1400 13-1600 75 75 22 75 75 75 75 132 160 200 250 1540 1540 800 1140 1140 1400 1400 1220 1100 1000 860 6000 6000 2200 6200 6200 6200 6200 10000 15000 20000 20000 Permissible Fan media weight temperature °C kg -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80 409 447 416 416 462 471 517 710 1100 1390 1870 Belt Driven Centrifugal Fans / Description Description Performance The curves show the total pressure rise pF as a function of the volume flow rate qV plotted in a double logarithmical diagram. The throttle curves (system resistance parabolas) are then represented by straight lines. The curves are established with a reference density of r1 = 1.2 kg/m³ at the fan intake. The pressure and impeller input power are directly proportional to density r1. Outlet velocity v2 and the dynamic pressure pd2 refer to the flanged cross section area at the fan discharge. psF = pF – pd2 The increase in static pressure psF when a duct is fitted to the discharge (Installation B) can be calculated from the equation: psF = pF – fpd × pd2 Where no duct is fitted (Installation A) there is no static pressure regain. The increase in pressure psF can be calculated from formula: The limits of application indicated in the fan curves (by blue dotted lines) outline the recommended functional range of the fans, where a stable operation with high efficiency can be expected. The efficiency marked on the straight system lines is only applicable at the maximum fan speed Nmax; it decreases with lower fan speed. RDH ADH 0160/-0560 0630/-1000 fpd 1.9 1.66 RZR 0200/-1000 see fan curves RZR 0180/-1000 1.74 1120/-1400 1.15 1120/-1600 1.00 10/10 2.24 22/22 2.42 12/12 1.94 25/25 2.49 15/15 2.17 30/20 2.44 AT fpd fpd Pr a = r ×— Pr + Pb 7/7 1.96 18/18 1.86 9/7 2.16 20/15 2.48 9/9 1.95 20/20 2.26 10/8 2.08 22/15 2.46 12/9 1.83 25/20 2.48 15/11 2.10 28/20 2.37 18/13 1.98 30/28 2.41 Efficiency ADH / AT / RDH The performance curves Pr of the fan curve diagram correspond to the absorbed power of the fan impeller. The vertical scales shown at the right side of the diagram indicate the bearing power loss Pb of the different fan executions and depending on the fan speed. The resulting power absorbed on fan shaft is found by adding the absorbed power Pr of the fan impeller and the bearing power losses Pb. As a consequence the resulting fan efficiency is to be calculated according to the formula: Efficiency RZR The actual efficiency value for a fan speed lower Nmax is calculated by multiplying the efficiency at Nmax by the factor fh for the appropriate speed. (fh to be found with the scale on the right side of the page). PN Pa × fP Motor nominal power ADH / AT / RDH / RZR To determine the motor rating PN, the fan absorbed shaft power Pr must be increased by a safety factor to accommodate belt drive losses and possible fan speed differences. The factor fp is an estimated value. As an approximate value, the figures below are suggested. ADH / AT Pa < 0.75 kW Pa ≥ 0.75 kW ... < 10kW Pa ≥ 10 kW RDH / RZR fp = 1.30 fp = 1.20 fp = 1.15 Pa < 0.75 kW Pa ≥ 0.75 kW ... < 10 kW Pa ≥ 10 kW fp = 1.25 fp = 1.15 fp = 1.12 81 Belt Driven Centrifugal Fans / Description Description Performance 8 × J × N² tA =— PN × 106 When selecting the motor, the run up time must be checked whether being within permitted limits. The run up time can be worked out approximately according to the following formula: where: tA = run time in seconds J = moment of inertia in kgm² N = fan speed in rpm PN = nominal motor power in kW (Impeller weight and moment of inertia can be found on the performance diagram for each fan size.) If tA exceeds the motor manufacturer‘s recommendation or the tripping period of the electrical gear, a larger motor must be used or the starting gear has to be selected for heavy starting. 1 = Test fan 2 = Discharge duct 3 = Screen 4 = Multiple nozzles 5 = Auxiliary fan and damper Fan curves measurement ADH / AT / RDH - AMCA 210-99 / ISO 5801 1 2 3 4 5 pe4 1 = Test fan 2 = Discharge duct acting as a pressure regain unit 3 = Screen 4 = Variable damper 5 = Compensating fan 6 = Flow straightener 7 = Inlet cone pe6 p Fan curves measurement RZR - ISO 5801 / DIN 24163 2 1 3 4 5 6 pa ta t1 psF qV = f(po) 7 po Performance data of twin fan units The performance data of twin fan units (Identification "G2") can be calculated, starting from that in the corresponding operating point of a single fan, with the following formulas: A Fan Pressure: pF G2 = pF × 1 A Volume flow rate: qV G2 = qV × 2 A Fan shaft power: Pa G2 = Pa × 2,15 AR otational speed: N G2 = N × 1,05 A Sound:LWA G2 = LWA + 3 dB AMCA Nicotra Gebhardt S.p.A. (Italy) certifies that ADH E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0160 to 0560, RDH E fans of the E0, E2, E4, E6 and E7 versions, from sizes 0180 to 0560, ADH and RDH fans of the L, R, K, K1 and K2 versions, from sizes 0630 to 1000, AT fans of the S, SC, C and TIC versions, from sizes 7/7 to 30/28, shown herein are licensed to bear the AMCA Seal. Nicotra Gebhardt GmbH (Germany) certifies that RZR fans of the 11, 12, 15 versions, from sizes 0355 to 1000, shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Air performance with Installation Type “A” (“with free outlet”), and that of the twin fan versions G2L, G2R, G2K, G2K2, G2E0, G2E2, G2E4, G2E7, SC2, G2C and G2C-C2, and that of the triple fan versions G3C and G3C-C2 in any installation type is not AMCA licensed. 82 Belt Driven Centrifugal Fans / Description Description Sound Noise measurements are undertaken in accordance with DIN 45635-38 “Noise Measurement of Machines: Fans”. Induct Method for the Discharge The induct method is specified with DIN EN ISO 5136. It determines the sound power emitted at discharge of a test fan. The test duct, as a main feature, is equipped with an anechoic termination fitted to avoid end reflection going back into the duct. Envelope Method – Free Inlet The Envelope Method is described with DIN 45635-1 and -38, which specifies a hypothetical box shaped measurement surface with several prescribed measurement points. 1 = Air permeable sound screen 2 = Microphone positions for envelope method 3 = Test fan 4 = Measuring duct 5 = Microphone with sampling tube 6 = Anechoic termination 7 = Step less adjustable throttle 1 2 3 4 5 6 7 Lp4 Lp7 psF The sound data of the fan curves are given as “A” weighted sound power levels. A-sound power level RZR The “A” weighted sound power level are identical for fan intake (LWA7) as well as for fan discharge (LWA4). LWA4 = LWA7 + LWrel4(A) ADH / AT / RDH: LWfc7 = LWA7 + LWrel7 LWfc4 = LWA7 + LWrel4 RZR: LWfc7 = LWA4;7 + LWrel7 LWfc4 = LWA4;7 + LWrel4 A-sound power level ADH / AT / RDH The “A” weighted sound power level (see curves) are apply for fan intake (LWA7). The fan discharge sound power level LWA4 is obtained by calculating: The correction value DLWrel4(A) is found with the table (left below) at the corresponding fan curve page (ADH / RDH) by introducing fan speed and flow rate. An approximation of the “A” weighted sound pressure levels LpA7/LpA6 at a distance of 1 m may be obtained by subtracting 7 dB from the relative “A” weighted sound power levels. If should be noted that site acoustics, duct design, reverberation, natural frequencies etc. can all influence noise to a greater or lesser extent. For more accurate calculations to determine noise protection measures, the sound power level in each octave band is of more value: The noise correction data LWrel4 und LWrel7, in function of the fan speed and flow rate, are to be found with the corresponding table on the fan curve page. In some cases the noise level - calculated by this way - may in some cases be higher than expected at the blade passing frequency. N×z fBP =— 60 fs = Blade passing frequency in Hz N = Fan speed in 1/min z = No of blades (see curve pages) 83 Belt Driven Centrifugal Fans / Description Description Sound LWfc6 = LWfc4 + LWer For a free discharge situation i.e. without duct connected the sound level will be lower because of an end reflection. This is specially true for low frequencies. For this case a correction may be applied to LWfc4 of the first 3 octave bands as follows: ADH / AT / RDH / RZR 0160/-0280 0315/-0800 0900/-1600 fc 63 125 250 Hz LWer LWer LWer -14 -9 -4 -9 -4 -1 -4 -2 0 dB dB dB Explosion protection according to ATEX Fans for use in explosive atmospheres must comply with EC Directive 94/9/EG (ATEX 95). Equipment in Group II (all applications except mining) is categorised in accordance with the required degree of safety for designated use in equipment categories 1, 2 and 3. Depending on suitability, a distinction is in addition made between G (gas, vapours) and D (dust). Harmonised European standards and national guidelines must be observed. Equipment in class 2 and 3 is not subject to compulsory specifications nor to type testing. The manufacturer declares conformity with the EC directive. For the standard designs of our fans, the following ignition sources are essentially to be considered: A Hot surfaces, e.g. due to heat of friction or seizure of a bearing or due to blockage of an impeller A Rubbing-, grinding- or beating sparks, e.g. as a result of contact of the impeller with stationary components A Sparks resulting from discharge of electrostatically loaded, non-conducting omponents, e.g. of plasticpanels, surfaces with strong layer thickness. Preconditions for operating: A In the proximity of the motor, the temperature limits -20 °C and +40 °C must not be exceeded. A The temperature limits of -20 °C und +60 °C for the flow medium must not be exceeded. If the temperature of the flow medium should exceed +60 °C on the pressure side, then the fan must be switched off! A The fans may only be employed with a horizontal shaft. A The fans are to be protected against the falling-in or sucking-in of foreign objects. Protection guards must be ordered separately as an accessories. A On the machine plate the max. permitted fan speed is indicated. A Fans for operation in ex-hazardous areas are marked as such on the machine plate and they are accompanied by an EU conformity declaration and with operation and maintenance instructions. The operation and maintenance instructions have strictly to be observed. The conformity is always related to the fan system supplied. If the fan is completed with motor and belt drive by the customer the conformity of this fan set has to be declared at new. Fans of the series ADH / AT / RDH in ATEX-Execution on request. 84 Belt Driven Centrifugal Fans / Description Description Operating limits RZR ATEX Permissible fan speed RZR 1/min Permissible shaft power Permissible nominal motor power kW kW 11-0200-2G 12-0200-2G 19-0200-2G 11-0225-2G 12-0225-2G 19-0225-2G 11-0250-2G 12-0250-2G 19-0250-2G 11-0280-2G 12-0280-2G 19-0280-2G 11-0315-2G 12-0315-2G 19-0315-2G 11-0355-2G 12-0355-2G 19-0355-2G 11-0400-2G 12-0400-2G 13-0400-2G 18-0400-2G 11-0450-2G 12-0450-2G 13-0450-2G 18-0450-2G 11-0500-2G 12-0500-2G 13-0500-2G 18-0500-2G 11-0560-2G 12-0560-2G 13-0560-2G 18-0560-2G 11-0630-2G 12-0630-2G 13-0630-2G 18-0630-2G 11-0710-2G 12-0710-2G 13-0710-2G 18-0710-2G 11-0800-2G 18-0800-2G 13-0800-2G 11-0900-2G 18-0900-2G 13-0900-2G 11-0100-2G 18-1000-2G 13-1000-2G 13-1120-2G 13-1250-2G 13-1400-2G 13-1600-2G 6513 6513 6513 5774 5774 5774 4620 4620 5076 4582 4582 4582 3793 3793 4113 3110 3110 3555 2552 2552 3145 2913 2111 2111 2922 2410 1752 1752 2534 2000 1660 1660 2163 1660 1367 1367 2055 1367 1128 1128 1825 1128 927 927 1474 767 767 1339 650 650 1217 1026 957 870 748 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 6.5 6.5 9.7 6.5 6.5 9.7 6.5 6.5 9.7 6.5 6.5 16.4 9.7 6.5 6.5 21.3 9.7 6.5 6.5 21.3 9.7 9.7 9.7 26.6 9.7 9.7 9.7 32.8 9.7 9.7 9.7 40.9 9.7 9.7 9.7 40.9 9.7 9.7 68 9.7 9.7 68 83.6 122 145 181 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 7.5 7.5 11 7.5 7.5 11 7.5 7.5 11 7.5 7.5 18.5 11 7.5 7.5 24 11 7.5 7.5 24 11 11 11 30 11 11 11 37 11 11 11 45 11 11 11 45 11 11 75 11 11 75 92 135 160 200 85 Belt Driven Centrifugal Fans / Description Description Symbol / Unit / Definition The following symbols are used in this catalogue: A-A 86 - The following symbols are used in this catalogue: Operational range (free discharge) PN kW Motor power (nominal) A2mm² Fan outlet area psF Pa Fan static pressure (free discharge) b mm Deflection of belt under test force gp Pa Differential pressure Dr mm Impeller diameter gp0 Pa Pressure difference at the inlet measuring device fBP Hz Blade passing frequency gpDü Pa Pressure difference at the inlet cone fc Hz Octave centre frequency qv Volume flow rate fp - Motor size correction factor qVopt m³/h Volume flow at optimum efficiency Fp N Test force RW J/kg×K Specific gas constant fpd - Dynamic pressure correction factor (free discharge) t °C Temperature of flow medium fh - Correction at actual efficiency ta °C Temperature of discharge air in test chamber J kgm² Moment of inertia tA s Acceleration time K m²s/h Calibration factor for volumeter t1 °C Air temperature LT mm Centre distance Θ K Thermodynamic temperature at fan inlet LMg mm Measuring marks before tensioning (flat belts) u m/s Tip speed LMu mm Measuring marks after tensioning (flat belts) v2 m/s Outlet velocity LpA4 dB A weighted sound pressure level (discharge) vm2 m/s Average fluid velocity at discharge LpA7 dB A weighted sound pressure level (inlet) X mm Pulley position on shaft extension relative to bearing LWA dB A weighted sound power level z - No. of blades LWA4 dB In duct sound power level (discharge) e* mm Stretching value of flat belt LWA7 dB Casing and free inlet sound power level ha % Total efficiency at max speed LWfc4 dB Discharge sound power in the octave bands hr % Impeller efficiency LWfc7 dB Inlet sound power in the octave band hs % Fan total efficiency at max speed LWrel4 dB Relative sound power (discharge) rkg/m² Air density LWrel7 dB Relative sound Power (inlet) r1 Air density at fan inlet L10h h Nominal bearing life m kg Mass N 1/min Fan speed Nmax 1/min Maximum fan speed pa Pa Atmospheric pressure Pa kW Absorbed fan power Pb kW Bearing power losses pd2 Pa fan dynamic pressure at discharge pF Pa Total fan pressure m³/h kg/m² Belt Driven Centrifugal Fans / Description / Notes Notes Quality management system DIN EN ISO 9001 Nicotra Gebhardt quality is the result of a continuous company policy intended to guarantee that our product properties and features are clearly superior to comparable products. This already established company maxim led in April 1985 to the auditing and certification of the existing quality management system. In the following years it was updated to match the changing international and European standards. Modern production processes, monitored by our quality management system, guarantee a high repeat accuracy in production. This ongoing high standard of quality permits the establishing of the performance data in classes of accuracy in accordance with DIN 24166. The narrow tolerances ensure a high level of data reliability for our products. Machine Safety The fans contained in this catalogue are not machines in the sense of the EC Machine Directive. They are delivered with a manufacturer "Declaration of incorporation". The assessment of the dangers associated with the fan and necessary safety measures are based on the VDMA Unit sheet 24167: Fans; Safety requirements. The operating instructions give which safety measures are still necessary on assembly to ensure that the fans comply with the Machine Directive 2006/42/EC. Catalogue data We reserve the right to change any measurements and technical data in this catalogue in accordance with further development of our products. All information valid at the time of printing. 87 nicotra-gebhardt.com AUSTRALIA 65 Yale Drive, Epping, VIC 3076 Phone +61 3 9017 5333 Fax +61 3 8401 3969 E-mail [email protected] BELGIUM Haeghensgoed, 13 - 00/01 9270 Laarne Phone +32 (0)9-336-00-01 Fax +32 (0)9-336-00-05 E-mail [email protected] CHINA 88 Tai‘An Road, XinQiao, ShiJi, Panyu Guangzhou 511450 PR CHINA Phone +86 (0)20-2293 5700 Fax +86 (0)20-2293 5701 E-mail [email protected] FRANCE Leader's Park Bat A1 3 chemin des Cytises 69340 Francheville Phone +33 (0)4 72 79 01 20 Fax +33 (0)4 72 79 01 21 E-mail [email protected] GERMANY Gebhardtstraße 19-25 74638 Waldenburg Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-mail [email protected] GREAT BRITAIN Unit D, Rail Mill Way Parkgate Business Park Rotherham South Yorkshire S62 6JQ Phone +044 01709-780760 Fax +044 01709-780762 E-mail [email protected] INDIA Plot no 28F & 29, Sector-31,Kasna, Greater Noida-201 308 U.P (India) Phone +91 120 4783400 Phone +91 22 65702056 (Mumbai) Phone +91 80 25727830 (Bangalore) E-mail [email protected] ITALY Via Modena, 18 24040 Zingonia (BG) Phone +39 035 873 111 Fax +39 035 884 319 E-mail [email protected] 88 MALAYSIA Lot 1799, Jalan Balakong Taman Perindustrian Bukit Belimbing 43300 Seri Kembangan Selangor Phone +603 8961-2588 Fax +603 8961-8337 E-mail [email protected] SPAIN Ctra. Alcalá-Villar del Olmo, Km. 2,830 28810 Villalbilla-Madrid Phone +34 918-846110 Fax +34 918-859450 E-mail [email protected] SINGAPORE 3, Science Park Drive, # 04-07, The Franklin Singapore Science Park 1 Singapore 118223 Phone +65 6265 1522 Fax +65 6265 2400 E-mail [email protected] Nicotra Gebhardt Germany Nicotra Gebhardt Italy Nicotra Gebhardt GmbH Gebhardtstraße 19-25 74638 Waldenburg Germany Phone +49 (0)7942 101 0 Fax +49 (0)7942 101 170 E-Mail [email protected] Nicotra Gebhardt S.p.A Via Modena, 18 24040 Zingonia (BG) Italy Phone +39 035 873 111 Fax +39 035 884 319 E-Mail [email protected] SWEDEN Kraketorpsgatan 30 43153 Mölndal Phone 0046 101-302600 Fax 0046 31-878590 E-mail [email protected] THAILAND 6/29 Soi Suksawadi 2, Moo 4, Suksawadi Road, Kwang Jomthong, Khet Jomthong, Bangkok 10150 Phone +662 476-1823-6 Fax +662 476-1827 E-mail [email protected] UNITED STATES PO BOX 900921 Sandy, Utah 84090 Phone 001(801) 733-0248 Fax 001(801) 315-9400 Mobile 001(801) 682 0898 E-mail [email protected] http://www.gebhardtfans.com/ nicotra-gebhardt.com EN-TD3-CFB-2.5 – PDF1-August2013 Nicotra Gebhardt worldwide