2388 GB produktblade
Transcription
2388 GB produktblade
EZC FH 3 : Page 3.2 : 02.07 OJ Microcenter WATERLINE MICROCENTER FOR UNDERFLOOR HEATING Microcenter EZC-12 and EZC-32 Application EZC microcenter is suitable for connecting multiple room thermostats and electric actuators (thermo heads) on, for example, an underfloor heating system. • Recommended for control of underfloor heating in hydronic installations • Connection of up to 8 thermostats • Connection of up to 8 actuators • Versions for 230V AC or 24V AC connection • Demand controlled pump relay • Demand controlled relay for heating source (boiler) • Built-in switch • Night setback options FUNCTION Time control An external time control can be connected for either switching off the installation during night times, or for generating night setback signal to the thermostats. Pump out The EZC has a volt free relay output for pump control that will be energised when any connected room thermostat calls for heat. Demand output The EZC has a second volt free relay output that can be used to enable a boiler, or to open a motorised valve. It is permissible to connect more than 1 head to a single terminal, provided that both heads are to be controlled by the same room thermostat. PRODUCT PROGRAMME SUPPLY CONNECTIONS THERMO HEADS THERMOSTATS TYPE 230V AC 8 8 EZC-12-8 230V AC 4 4 EZC-12-4 24V AC 8 8 EZC-32-8 24V AC 4 4 EZC-32-4 EZC Microcenter is delivered including cover type ETT-KH © 2008 OJ Electronics A/S OJ ELECTRONICS A/S T. +45 73 12 13 14 STENAGER 13B F. +45 73 12 13 13 DK-6400 SØNDERBORG [email protected] DENMARK WWW.OJ.DK EZC EMR BR899A05 Dimensions (mm) EZC Microcenter in combination with temperature controller type EMR TECHNICAL DATA Supply Input Output Input time switch EZC-12-8 230V AC ±10%, 50-60Hz 8 x 230V AC 8 x 230V AC, max. 2A 230V AC EZC-12-4 - 4 x 230V AC 4 x 230V AC, max. 2A EZC-32-8 24V AC ±10%, 50-60 Hz 8 x 24V AC 8 x 24V AC, max. 2A EZC-32-4 - 4 x 24V AC 4 x 24V AC, max. 2A Max output total for actuators 10A Pump and demand relay 2 x SPST, volt free 24V AC max 6A or 230V AC max. 6A Interrupter, main supply only EZC-12-8 and EZC 32-8 STAT 7 MTU STAT 4 1 2 4 5 1 2 4 5 1 2 3 4 1 3 LINK For night setback insert one of the two links depending on the type of thermostat (see EZC instructions) LINK NSB N 1 N 1 L1 L1 L C N TYPE OF NSB 5 6 7 8 L1 L1 N 1 N 1 NSB 230V ROOM THERMOSTATS POWER I MICROCENTER EZC-12 0 HEAT DEMAND NSB LINK TIME SUPPLY 230V I O I O L N LINK LINK MAINS SUPPLY 230VAC FROM 10 AMP FUSED ISOLATOR L N PUMP DEM. PE O I O I 230V THERMO HEADS N1 N1 1 2 3 4 5 6 7 8 N1 N1 LINK PE N HEAD 1 HEAD 6 HEAD 2 HEAD 7 L UNDERFLOOR PUMP VOLT FREE OUTPUT FOR BOILER CONTROL, OR DEMAND SIGNAL FOR COMPENSATOR © 2008 OJ Electronics A/S 24V AC 3.3.2-02.07-EZC-GB · Subject to alterations · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S MTU BASIS WIRING DIAGRAM FOR 230V MICROCENTER EZC 12-8 WITH NIGHT SETBACK BR901A17 Type