Model 4110 Installation Instructions

Transcription

Model 4110 Installation Instructions
4110
INSTALLATION
INSTRUCTIONS
N4926VS 4/92 (MARGIN LINES INDICATE PRINCIPAL CHANGES IN THIS ISSUE)
CONGRATULATIONS
on your purchase of the VANTAGE
4110!
The purpose of these Installation
Instructions is to give you a brief overview
of the VANTAGE 4110 system, and provide instructions for installing a basic
system.
i’_ 1’
As always, ADEMCO is there for YOU! Our SALES and TECHNICAL SUPPORT
staff are eager to assist you in any way they can, so don’t hesitate to call, for
any reason!
East Coast Technical Support: l-800-645-7492 (8 a.m.-6p.m. E.S.T.)
West Coast Technical Support: l-800-458-9469 (8 a.m.-5 p.m. P.S.T.)
PLEASE,
Before you call Technical Support, be sure you have:
Checked all wiring connections and fuses.
l
Determined that the power supply and backup battery are supplying
proper voltages.
l
Verified your programming
information
where applicable.
l
Noted the proper model number of this product, and the version
level (if known) along with any documentation that came with the
product.
l
Your Ademco customer number and/or company name.
Having this information
handy will make it easier for us to serve you
quickly and effectively.
l
Again,
CONGRATULATIONS,
and WELCOME
ABOARD!
I
FOR YOUR CONVENIENCE, two easily removable
Programming Forms have been included at the
center of this manual.
I
Thissystem is not CaliforniaStateFire Marshall approved
and,as such, should not be used for fire protectionin California
(or other areas requiringsuch acceptance).
TABLE
OF CONTENTS
me Limitationsof this AlarmSystem ............. .14
Canadian DOC Statement ............................. 15
FCC Statement............................................. 16
UrnitedWarranty.......................................... .16
Diagrams
tnstaltingthe Lock (If Used). ............................. .
Installing the 4110 Circuit Board...................... .5
Summary of Connections................................ 6
ProgrammingFon ...................................... .l 0
General Information.. ...................................... .3
Remote Programming and Control.. ............... .3
Zone Types Available for Selection.. ............... .4
4-Digit Security Codes ................................... .4.
Mounting the Console(s). ............................... .5
Wiring Connections.. ..................................... .6
Programmingthe Security Control. ................. .7
Specific Address Programming Instructions.....B
Testing the System ....................................... 12
Accessories ................................................ .12
Specifications.. ............................................ .13
;q
...
’
-
-2-
GENERAL
INFORMATION
erasable, non-volatile EEROM memory. This means
that the unit can be reprogrammed many times
(unlike units equipped with PROMS) and that information which has been programmed will not be lost
in the event of a complete loss of power.
The system also provides communication capability
(central station repotting, etc.) over existing telephone lines. In addition, it can be uploaded or
downloaded via your computer and Hayes Modem.
This system includes an alarm output rated at
2 amps. Throughout the manual, wherever
reference Is made to Alarm Output Ratlngs,
they assume a fully charged battery Is connected unless the UL ratlng Is stated.
Zone Characterlstlcs
Zones l-6:
Programmable Zones, EOLR supervised, N.O. or N.C. sensors,
300-500 msec response.
Zone 3:
Past lo-15 msec response
optional.
The VANTAGE (No. 4110) is a microprocessorbased security control which provides up to 6 wired
zones. The security control is housed in a wallmounted metal cabinet measuring 12-112”(316mm)
wide x 14-l/2” (366mm) high x Y,(76mm) deep, and
can be used with a console equipped wtth a multifunction 1Bkey digital keypad and a numeric and
fixed English status LCD display (4127). Optionally, a
No. 4137 may be used or a No. 5330 Alpha Console
(select for Vector device, as descrfbed in the 5330’s
installation instructions) may be used with the control
to provide programmable English language zone
descriptors and status indications. The system may
also be aned and disarmedusing a keyswitch.
Connections to the security control are made via a
21-terminal connector block which is used to interface to the wired loops, plug-in transformer, telephone line, remote’ console(s), external alarm
sounder(s), etc. The security control can be easily
programmed from any of the above remote consoles. Programmed options to establish specific
alarm and reporting features are stored in electrically
REMOTE
e
PROGRAMMING
The No. 4110 can be remotely programmedfrom an
IBM compatible Personal Computer (PC), a Hayes
Modem, and using Ademco’s V-LINK@ Software.
Programming the No. 4110 from a remote location fs
prot8cted against compromise by using multi-levels
of security protection:
.I. Security Code Handshake: An e-digit download ID
code must be matched between the No.4110 and
the downloader.
2. Site Initiated Remote Programming: The installer
or subscriber initiates the callback from the
subscriber premises (by pressing MASTER CODE
+ # + 1). All parameters can then be downloaded
via the phone fines using a personal computer.
3. Data Encryption: Data passed between the PC
and the No. 4110 is encrypted for sear&y so that it
is very difficult for a foreign device tapped into the
phone line to take over communication and
substitute system comromising information.
Equlpment
Requlred: 4110 and console (at
premises), an IBM PC compatible computer, a Hayes
brand Smamnodem 1200 (Level 1.2 or higher external
or Level 1.1 or higher internal style), No. 4130PC
Downloading Soft-ware Diskette (Rev. 1.5 or higher),
and appropriate interconnecting cables.
-3-
AND CONTROL
Programmlng:
The system uses only two
commands, one for uploading and one for
downloading.
Notes: After the 4110 and the PC have established
valid communication, each console on the system
will become inactive. The consoles will become active after the download communication is termfnated.
The detailed operation of the download functions is
covered in the installation instructions for the
4130PC Downbad Software Diskette.
Remote Programmlnfl Advlsory Notes:
Alarm and Trouble reporting are disabled during the
time that the system and the central station are
linked to each other following a valid exchange of
codes.
Keypad entries are ignored during the time interval
st8t8d above.
Should an alarm occur durlng the remote
program Interval, the sytem would not
respond to the alarm condltlon.
A copy of the program downloaded may be produced from the IBM PC compatible computer, using
the product’s internal report generator, When an
optional printer is connected (consult your PC
manual for proper printer and connections).
Program Download Time-Less than 45 seconds
for a complete program.
ZONE NPES
AVAILABLE
FOR SELECTION
For each zone used, one of the following zone types must be selected:
the system will provide latched Console annun0. Zone Dlsabled
ciation (and central station report, if desired) of r\
1. EntrylExlt Burglary. Assigned to sensors on
openings or troubles (such as sensor malfunc- _ /’
doors through which entry and exit -will normally
tions
or foil breaks). During the armed state
take place when the system is armed.
(night),violationswill initiate an alarm.
2. Supervlsed Fire With programmable bell
6. 24=hour Sllent Alarm. This type generally
timeout. (alarm on short/trouble on open). .Fire
assigned to a zone containing an Emergency
zone may not be bypassed. Only usable on
button
that is designed to initiate an alarm report
Zone 5 or Console Panic.
to the Central Station, but which produces no b3. Perlmeter Burglary. Normally assigned to all
cal displays or alarm sounds.
sensors on exterior doors and windows requiring
26hour Audlble Alarm. This type also as7.
instant alarm.
signed to a zone containing an Emergency but4. Interlor, Follower. Delayed alarm only if the
ton, but which will initiate an audible alarm in adEntry/Exit zone is faulted first; otherwise, prodition to an alarm report to the Central Station.
duces an instant alarm. Assigned to zone cover24-hour Auxlllary Alarm (Console sounder
8.
ing an area such as a foyer or lobby through
only). This type assigned to a zone containing a
which one must pass upon entry to reach the
button for use in personal emergencies, or to a
keypad to disarm the system. Designed to prozone containing monitoring devices such as wavide instant intrusion alarm in the event an inter sensors, temperature sensors, etc. Designed
truder hides on the premises prior to the system
to initiate an alarm report to the Central Station
being armed or gains access to the premises
and only provides Console warning sounds and
through an unprotected area.
alarmdisplays.
5. Trouble by Day/Alarm by Nlght. Can be
Supervised Flre Without programmable bell
9.
assigned to a zone which contains a foil-protimeout.
(alarm on short/trouble on open). Fire
tected door or window (such as in a store), or to a
zone
may
not be bypassed. Only usable on
zone covering a “sensittte’ area such as a stock
Zone
5
or
Console Panic.
room, drug suppfy room, etc., or other controlled
access area where immediate notification of an
entry is desired. During the disarmed state (day),
&DIGIT
SECURITY
Master Security Code:
The Installer programs the Master Code initially as
part of the programming procedure (see ‘Programming the Securfty Controll). The Master code
permits m-entry into the programmingmode and also
allows access to the norrnaffunctions of the system.
I 11I[ I[ 1 Mamr CoMU=rWs
assigned during programming.
Installer exits programmingmode with:
‘98
(prevents re-entry into programming
mode with Master code).
l 99 (allows re-entry Into programming mode
with Master code).
1
By exiting with l 96, the only method of getting
back into the programming mode from the
console is to completely depower the system
and follow the procedure noted in the section
on “Programming the Security Control”.
The Master security code can be used to assign up
to three secondary codes: it can also be used to remove all secondary codes from the system
(individually).
CODES
Secondary Security Codes:
Secondary security codes are asslgned by Master
Code as folbws:
Master Code + CODE key + User # (2 - 4)
+ Secondary Code
The system will emit a single beep when each
secondary code has been successfully entered.
Note:
When a secondary code is inadvertently
repeated for different users, or one user’s
code is another’s duress code, the lower
user number will take priority.
Individual secondary security cpdes can be deleted
by user #l (with Master Code) as follows:
MasterCode + CODE key + User # (2 - 4)
Note:
All security codes, master and secondary,
permit access to the system for arming,
disarming, etc.
INSTALLING
THE LOCK (IF USED)
(The cabinet can be closed and secured wifI?o&a lock by using 2 screws in the covets edge.)
Use Ademco No. N6227 Cam Lock and No. N6227-1 Push-On Clip (Retainer Clip).
1. Remove the cabinet cover.
It is easily removable toi
servicing and is easily reinstalled.
2. Remove the lock knockout
from the control cabinet
cover. Insert the key into the
lock. Position the lock in the
hole making certain that the
latch will make contact with
the latch bracket when the
door is closed.
3. While holding the lock
steady, insert the retainer
clip into the retainer slots.
Position cGpas illustrated to
facilitate easy removal.
INSTALLING
THE 4110 CIRCUIT
BOARD
BEFORE MOUNTING THE CIRCUIT BOARD, be sure to remove the appropriate metal
knockouts from the cabinet. DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS AFTER THE
ClRCUlT BOARD HAS BEEN INSTALLED.
1. Hang two short mounting
clips -(provided) on the
raised cabinet tabs (see
lower detail side view at
right).
2. Insert the top of the circuit
board into the slots at the
top of the cabinet. Make
sure that the board rests on
the correct row (see the upper detail side view at right).
3. Swing the base of the board
into the mounting clips and
secure the board to the
cabinet with the accompanying screws (as illustrated in
fewer detail).
Note:
a
MOUNTING
THE 4127 CONSOLE(S)
4. Pass the inte&ce wiring through the opening in
the backplate and then mount the backplate to
the wall surface with screws.
5. Splice the interface wiring to the console wires.
Insulated solderless wire splices (such as
Ademco No. 311) may be used for splicing.
6. Attach the main body of the console to the wallmounted backplate. The console is properly attached when it is screwed to the backplate by
top and bottom screws.
Separate the console from its backplate by removal of the two screws on the top and bottom
edges.
2. Use the backpiate to mark the positions on the \
wall for the screw mounting holes and the cutout for the interface wiring. Use wall anchors for
the screws and make the cutout in the wall no
larger than indicated on the template. The backplate is designed to be directly mounted to either a single or double gang electrical box.
3. Pull the interface wiring in the wall through the
cut-out.
1.
-5-
WIRING CONNECTIONS
IMPORTANT:
Do not connect
wiring
the battery, or plug in the AC tranaformer,
connections
have been completed.
Grounding
the System
Terminal 21 is the earth ground connection point. In order for
the protective devices in this product to be effective. the
designated terminal must be terminated in a good earth
ground. The following are examples of good earth grounds
available at most installations:
Metal cold water pipe: Use a .non-corrosive metal strap
firmly secured to the pipe to which the lead is electrically
connected and secured.
TERMINALS
1 8 2: AC Input from No. 1321m2 plug-in transformer, in
U.S.A. (16.5VAC. 25VA)
NOTE: In Canadian installations. a 1321CN transformer
must be used.
3:
Alarm relay output(+), 12VDC. 2.OA maximum (600mA
max. Alarm plus Aux. Power, for UL usage).
4:
Alarm Output I Auxiliary Power I Fire I Console I
Optional Keyswitch (BLACK lead) Ground (-) Return.
5:
Auxiliary I Fire I Console I Optional Keyswitch (RED)
Power: +lPVDC at SOOmA max. t.
6:
Data In from Console ! Optional Keyswitch (GREEN)t.
7:
Data Out to Console/Optional Keyswitch (YELLOW$.
8:
Zone 1. (When Zones are used, a 1,000 Ohm EOLR
should be wired between the farthest sensor connected
to the zone terminal and the bw side of the zone.)
9-l 6: Zone wiring and zone returns.
until
all other
AC power outlet ground: Available from &prong, 120
VAC power outlets only. To test the integriiy of the ground
terminal, use a 3-wire circuit tester with neon lamp indicators.
such as the UL Listed Ideal Model 61-035. or equivalent,
available at most electrical supply stores.
WARNING: To prevent
Handset (TIP).
risk of electrical shock,
Handset (RING).
disconnect telco jack
lnmming Phone Line (TIP).
lnmming Phone tine (RING). before servicing unit.
EARTH GROUND (a proper earth ground must be
provided to protect the system from lightning and
electrostatic discharge damage).
t Multiile consoles may be used, but each Ademco 5330
Console must be on an individual home run. Use no more
than 220’ of 1122wire or 550’ of tl8 wire.
Battery(+). When AC is present, 13.8VDC
RED LEAD:
is being developed to recharge a gel lead acid battery and
when AC is absent, 12VDC cunent is drswn from the battery.
Battery lead reversal will blow the battery fuse.
BLACK LEAD:
Battery (-).
17:
18:
19:
20:
21:
SUMMARY OF CONNECTIONS DIAGRAM
rrcuIo*uyyI
WARNING:10
=-
PREVENT THE RISK
OF SHOCK, DISCONNECT
s
TELEPHONE LINE AT
Ju) TELCC JACK BEFORE
f-+-J
‘,,_ ,:
e
@.
The following is a description of commands necessary for programming:
PROCEDURE
FUNCTION
Installer options are stored in non-removable,electrically erasable, non-volatile EEROM memory.’ These
options must be programmedfor the particular installation to establish its specific alarm and reportingfeatures. The security control may be programmedfrom
a remote console.
When programming, the field number will be displayed on the LCD display; also, each entry is displayed as it is keyed in. After programming, values
that have been entered in each field can be reviewed and, if necessary, modified.
*Note: It is possible to program the system at any
time - even at the installer’s premises prior to the actual installation. Simply apply power temporarily to
the control and then program the unit as desired.
When programming from the console, note the following:
1. Enter the Programming mode by simultaneously
depressing the r] and [t] keys within 50
seconds after power Is applled to the
Control, or subsequently by keying the code
4 + 1 + 1 + 0 followed by depression of
CODE + 0 keys. Once a Master code is
programmed, use it instead of 4110 to gain
access to the Programmingmode.
2. Immediately following entry into the program
mode, 20 will be displayed. (If a 5330 console is
used, 00 will be displayed. Enter ‘20 to access
the programming start point). Following the
above display, the system is ready to accept entries for Address 20.
To program a data field, key r] plus Address
(for example, ‘21). then make the required entry.
To simply review a data field, key [#I plus
Address.
3. When a data field has been completely programmed, the console will normally %eep” three
times and then automatically proceed to, and
display, the next data field address to be programmed (if not, key r] plus the address of the
next field to be programmed).
4. If the number of digits that you enter in the data
field is less than the maximum permitted (for example, phone number), then the console will
display the last data entered. To proceed, the
next data field address to be programmed must
then be entered (for example, ‘42).
5. If an address is improperly entered, the console
will display EE. Simply re-enter l or # plus the
number.
1. POWER UP. then deoress
r] and [#] simultanebusly
within 50 seconds of powering up.
OR
2. Initially, Key: 4 + 1 + 1 + 0
plus CODE key + 0.
OR
3. After Master Code is programmed, key: Master
Code + CODE key + 0.
(If ‘98 was used to exit previously, method 1 above mrst be
used to enter the program mode
again.)
l 99
(allows rsentty to proE~!!AAMMING
gramming mode via Type 3
MODE
entry method above)
l 9 8
(inhibits re-entry to programming mode via Type 3
entry method)
ADVANCE TO FIELD: [1+ ADDRESS (e.g. 21,
35.52, etc.).
PROGRAMFIELD:
m + ADDRESS, followed
by data entries.
ERASE FIELDS:
[1+ ADDRESS + r] (only
applies 10Addresses 40
thru 43 and 94.)
READ FIELD:
[#I + ADDRESS
SPECIAL MESSAGES,
ocOPEN CIRCUK (no communication between
the Console and the Control).
EE - ERROR (program entry mistake, m-enter the
data).
After powering up, AC, dl (disabled) and NOT
READY will be displayed after approximately 4 seconds. This will revert to READY in appx. 1 minute,
which allows PIRS, etc. to stabilize. To bypass this
delay, press: # + 0.
ENTER
PRO&RAMMING
MODE:
-7--
SPECIFIC
ADDRESS
PROGRAMMING
INSTRUCTIONS
Note: The followlng shows Factory Default Settings withln brackets: [ ]
1 THE PROGRAMMING FORM PRINTED ON PAGE 10 CAN BE USED TO RECORD THE DATA FOR THIS INSTALLATION
SYSTEM ARMING (*20-•23)
l 20
MASTER SECURITY CODE
[4][1][1][0] Enter 4 digits, O-9 (entry of all 4
is mandatory). Use of a ‘9” in the last
position inhibits the Ambush feature.
l 21
QUICK ARM ENABLE
[0 ] Enter 1 for enabledor 0 for disabled
‘22
KEYSWITCH ENABLE
[0 ] Enter 1 for enabled or 0 for disabled
‘23
FORCED BYPASS ENABLE
[0 ] Enter 1 for enabledor 0 for disabled
ZONE RESPONSE PROGRAMMING l 29-•39
‘30
ALARM BELL TIMEOUT
[l ] Externalsounderwill shut off after time
allotted. Enter 1 digit.
8 minutes= 2
No timeout = 0
12minutes=3
4 minutes = 1.
Use the foiiowlng table of zone types for
programming addresses l 31-•37
O=Zone Disabled
I= ENTRYIEXfT,Burglary
2= FIRE (w/timeout)
3= PERIMETER, Burglary
4= INTERIOR, FOLLOWER,Burglary
5.: TROUBLE BY DAY/ALARMBY NIGHT, Burglary
6- 24 Hr (Silent)
7= 24 Hr (Audible)
8=24Hr (Aux)
90 FIRE (w/o timeout), Fields ‘35 & l 37 only
‘31
RESPONSE TYPE FOR ZONE 1
[l ] Enter 1 digit
l 32
RESPONSE TYPE FOR ZONE 2
[4 ] Enter 1 digit
RESPONSE TYPE FOR ZONE 3
‘33
[3 ] Enter 1 digit
RESPONSE TYPE FOR ZONE 4
‘34
[3 ] Enter 1 digit
RESPONSE TYPE FOR ZONE 6
‘35
[2 ] Enter 1 digit,
RESPONSE TYPE FOR ZONE 6
‘36
[7 ] Enter 1 digit
RESPONSE TYPE FOR ZONE 7
*37
(Console Panic)
[6 ] Enter 1 digit
Only zone types 0.2,6,7,8,9 applicable.
ENTRY/EXIT DELAY
‘38
[2 ] System will wait the time allotted before
sounding alarm upon entering. Enter 1 digit.
Exit delay = Entry delay plus 15 seconds
2 = 30 Seconds
0 = 0 seconds
3 = 45 Seconds
1 = 20 Seconds
ZONE 3 RESPONSE TIME TO OPEN
‘39
[ 0) 400 ms nominal = 0
10msnominal =l
-8-
[
DIALER PROGRAMMING (‘40.•48)
l 40
PABX ACCESS CODE
[ ] [ ] [ ] [ ] Enter 4 digits, O-9, for each
PABX digit needed to access an outside
line. To skip this field, enter l . If l is entered,
no PABX number will be dialed and nothing
will appear in this field. End field by entering
‘41 if not filled. To clear entries from field,
press ‘40’.
‘41
PRIMARY PHONE No.
I I[ I[ I[ 11 I[ I[ II II II Ii I[ 1
‘42
Enter UD to 12 diaits. O-9. Do not fill unused
spaces: End field-by entering ‘42 if not filled.
To clear entries from field, press ‘41’.
Note: Back-up reporting (8 calls are made to
the secondary phone number if no acknowledgment is received after 8 attempts to the
prfmary number) is automatic only ff there is a
secondary phone number.
SECONDARY PHONE No.
1 I[ I[ I[ I[ 11 I[ I[ I[ I[ I[ I[ 1
‘43
‘44
‘45
‘46
‘47
See above. End fiekf by entering ‘43 if not
filled. To dear entries from field, press l 42’.
SUBSCRIBER ACCT. No.
(151[15][ 15x151
Enter digits O-9; #+l l=B; #+12=C;
#+13=D; #+14=E: or #+lS=F. Enter l as the
fourth digit if a 3 digit accf no. (for 3+1 dialer
reporting format) is used. Enter 0 as the first
digit of a 4-digit acct no. for nos. OOOO0999. End field by entering ‘44 if only 3
digits are used. To clear entries from field,
press ‘43’.
REPORT FORMAT
f 0 ] Determine which format is to be used to
report to central station. Enter 1 digit.
0 = 3+1; 4+1 ADEMCO US Standard
1 - 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Lo Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
8 = 3+1; 4+1 ADEMCO Lo Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
(Enter l as the 4th digit of l 43 if 3+1 dialer
reporting is to be used.)
PHONE SYSTEM SELECT [ 0 ]
Enter 1 digit.
If Central Station Rcvr is rxrron WATS tine:
0 = Pulse Dial
1 = Tone Dial
ff Central Station Rcvr is on WATS line:
3=ToneDial
2 = Pulse Dial
FUTURE USE [0]
Enter 0.
15 SECOND DELqY ;;i
BURG [ 0 ]
=
O-NO
ConCnu8don PaQe9 e
.
4110 PROGRAMMING
FIELD
SYSTEM
PROGRAMMED
FUNCTION
ARMING
MASTER SECURflY CODE
‘21
GUlCK ARM ENABLE
‘22
KEYSWITCH ENABLE
‘23
FORCED BYPASS ENABLE
RESPONSE
Enter 4 digits, O-9
0Elncl
t 0
0 I no. 1 I yes
+Elo
t f-J
PROGRAMMING
tt qq
‘30
ALARM BELL TtMEOUT
‘31
ZONE 1 RESPONSE TYPE
‘32
ZONE 2 RESPONSE TYPE
cl
‘33
ZONE 3 RESPONSE TYPE
cl
‘34
ZONE 4 RESPONSE TYPE
cl
‘35
ZONE 5 RESPONSE TYPE
cl
‘36
ZONE 6 RESPONSE TYPE
cl
‘37
ZONE 7 RESPONSE TYPE
cl
‘36
ENTRY DELAY
‘39
ZONE 3 RESPONSE TO OPEN
DIALER
VALUES
(‘200’23)
‘20
ZONE
FORM
PROGRAMMING
i-fq
t 0
I no, 1 -yes
O-no,1
-yes
(*29=39)
O=none;l
=4min;2=8min,3=12min
ZONE TYPES FOR PROGRAMMING FIELDS ‘31-37
0 (or undefined) - Zone Disabled
11 ENTRY/EXlT. Burglary
2 I FIRE with timeout
3 I PERIMETER, Burglary
4 - INTERIORIFOLLOWER, 8urglary
5 I TROUBLE BY DAY/ALARM BY NIGHT, Burglary
6 I 24 Hr (Silent)
7 - 24 Hr (Audible)
8 = 24 Hr (Auxiliary)
9 I FIRE without timeout (Fields ‘35 and ‘37 only)
..
c
CONSOLE PANIC. Onty zone types 0.2,6,7,8,9
applicable.
0=0sec;1=20sec;2r30sec;3=45sec
EXlTDelay=ENTRYDetay+lSsec
0 I 400 ms nominal; 1 - 10 ms nominal
(*40-•47)
‘40
PABX ACCESS CODE
Enter 4 digits, O-9. ff fewer than 4 digits entered, exit by
clclocl
pressing l (and press 41, lf entering next field). To clear entriis from field, press ‘40’.
‘41
PRIMARY PHONE No.
nnnnnnnnnnnn
9. Do not fill unused spaces. If fewer than 12 digits entered, extt by pressing
field). To clear entries from field, press ‘41’.
l
Enter upto 12digits. O(and press 42, if entering next
SECONDARY PHONE No.
nnnnnnnnnnnm
9. Do not fill unused spaces. If fewer than 12 digits entered, exit by pressing
field). To clear entries from field, press ‘42’.
l
Enter upto 12digits, O(and press 43, if entering next
‘42
‘43
Enter O-9; #+l 1 for B; #+12 for C:#+l3
SUBSCRIBER ACCOUNT No.
EIxzlII
for D; #+14 for E: #+15 for F. lf only 3 digits used. exit by pressing l (and press 44, if entering next field). To
clear entries from field, press ‘43’.
Examples: For Acct No. 1234. enter: m
/2)
-1
7)
For Acct No. 8234. enter: rf
121
131
141
For Acot No. 123. enter: 17
121
131
1’1
Enter ’ as the 4th digit of ‘43 if 3+1 dialer reporting is to be used.
cl
0 I 3+l, 4+1 ADEMCO LJSSTANDARD 6 or unshed = 4+2 ADEMCO EXPRESS
1 I 3+1.4+1 RADIONICSSTANDARD
6 = 3+1,4+1 ADEMCO US EXPANDED
2 = 4+2 ADEMCO US STANDARD
9 = 3+1,4+1 RADtONlCS EXPANDED
3 = 4+2 RADIONICSSTANDARD
‘44
REPORT FORMAT
‘45
PHONE SYSTEM SELECT
l 46
FLmJREu8E
l 47
15 SEC DlALER DELAY (BURG) t 0
tf
0
t 0
lf Cent. Sta. IS NOT on a ‘WATS time: 0 = Puke Dii; 1 = Tone Dial
H Cent. Sta IS on a WATS line: 2 I Pulse Dii; 3 I Tone Dial
Enter 0.
0 = no, 11 yes
t If a number other than 0 or 1 is entered. even numbers = same as 0; odd numbers = same as 1.
ff If a number greater than 3 is entered, the control will subtract multiples of 4 to gel to the allowable pro9rarn range.
41 lOPRV2 4IQ2 (See Insauctions N4926VS)
OVER*
RESTORE
REPORT
CODES (‘51-‘74):
Wlth a 3+1 or 4+1 Standard F&mat:
Enter a code
in the first box: l-9, 0, B. C, D, E, or F. Enter [#+lO] for 0,
[#+ll) for 8, [t+l2] for C. [#+13) for D, [#+14] for E. [#+15]
for F.
A [0] (nor [#+lO]) in the first box will disable a report.
A [0] (nor [#+lO]) in the second box will result in auto&tic
advance to the next fiik! when programming.
With an Expanded or 4+2 Format: Enter codes in
both boxes (1st and 2nd digits) for 1-9, 0, or B-F, as described above.
A [O] (not [#+lO]) in the second box will eliminate the expanded message for that report.
A [O] (not [#+lO]) in horh boxes wilt disable the repon.
rl
Examples: For Code 3 (Smgle D@it). enter: )3)
ALARM
For Code 32 (Two Digits). enter: 131
121
For Code B2 (Hexadeama!) enter: IkllJ
12)
REPORT
CODES
RESTORE
RPT CODES
(‘70=74)
‘70
ALARM RESTORE RPT CODE
cl
2nd digit is automatically sent as the 2nd
digit of the zone alarm report code
programmed in ‘51-‘59, if expanded or 4+2
reporting is selected.
‘71
TROUBLE RESTORE RPT CODE
[I
l 72
BYPASS RESTORE RPT CODE
III
‘73
AC RESTORE RPT CODE
III
‘74
LOWBATRESTORERPTCODE
IT1
DOWNLOAD
INFO
I]
(‘94=97)
‘94
r;y,Pli;“;No.l
‘96
Enter up to 12 digits, O-9. Do not fill unused spaces.
H fewer than 12 digits entered, exit field by pressing
(and press 95. if entering next field). To clear entries from field, press ‘94’.
INITIALIZES DOWNLOAD ID, SUBSCRIBER
ACCOUNT No. FOR INITIAL DOWNLOAD
No entry required.
ZEROS ALL PROGRAM FIELDS
No entry required.
(c51-‘59)
]“,
,,
I,
,I
]
l
‘51
ZONE 1 ALARM FIEPOFIT CODE
III
‘52
ZONE2AlARMREPORTCODE
rjil
‘53
ZONE 3 AIARM REPOFtT CODE
1-i
‘54
ZONE4AlARMREPORlCODE
IIrj
‘55
ZONE5ALARMFtEPORTCODE
IIT1
l 56
ZONE 6 ALARM REPORT CODE
II
‘57
ZONE7AfARMREPORTCODE~
(Console Panic)
nr1
‘56
ZONE8AlAFIMFU’OFlTCODE
(Duress)
nr1
‘59
ZONE 9 AIARM REPORKC~)
I-III
SYS
STATUS
‘60
TROUBLE REPORT CODE
III
‘61
BYPASS REPORT CODE
ElII
‘62
AC LOSS REPORT CODE
III
‘63
LOW BAT REPORT CODE
III
‘64
TESTREPOFfTCODE
III
‘65
OPEN REPORT CODE
I
‘66
RPT
CODES
II
TO EXIT PROGRAM
rj
(‘SO-‘66)
l-t-t
MODE (‘98
or ‘99)
Press ‘98 or ‘99 if exiting programming, or next field
number if wntinuing.
‘98
EXRS PROGRAMMING MODE and
prevents re-entry by: Master Code + Code + 0.
‘99
m
REPORT CODE
El
I CLOSE
..
TTT 2nd diiit is automatically sent as the user
number
if. expanded or 4+2 reporting is
.
411OPRVP4192(See Instructions N4926V5)
‘97
EXmS PROGRAMMING MODE and
elkws re-entry by: Master Code + Code + 0:
(‘71
IX ,/
~~EMcoJ
FIELD
SYSTEM
4110 PROGRAMMING
FUNCTION
ARMING
PROGRAMMED
VALUES
(‘20~‘23)
‘20
MASTER SECURITY CODE
‘21
QUICK ARM ENABLE
Enter 4 digits, O-9
17000
I no, 1 = yes
q-Jo
‘22
KEYSWTTCH ENABLE
tcJo
*no,1
-yes
‘23
FORCED BYPASS ENABLE
tOo
-no,1
-yes
ZONE
RESPONSE
PROGRAMMING
AIAFIM BELL TtMEOUT
‘31
ZONE 1 RESPONSE TYPE
Cl
‘32
ZONE 2 RESPONSE TYPE
cl
‘33
ZONE 3 RESPONSE TYPE
0
‘34
ZONE 4 RESPONSE TYPE
0
‘35
ZONE 5 RESPONSE TYPE
0
‘36
ZONE 6 RESPONSE TYPE
0
‘37
ZONE 7 RESPONSE TYPE
‘38
ENTRY DELAY
0
t’t 0
l 39
ZONE 3 RESPONSE TO OPEN
PROGRAMMING
(*29=39)
=none;1=4min;2=8min,3=12min
‘30
DIALER
FORM
CJO
t 0
’ ZONE TYPES FOR PROGRAMMING FIELDS ‘31.37
0 (or undefined) I Zone Disabled
1 - ENTRY/EXIT, Burglary
2 - FIRE with timeout
3 I PERIMETER, Burglary
4 = INTERIOR/FOLLOWER. Burglary
5 I TROUBLE BY DAYIAIARM BY NIGHT, Burglary
6 I 24 Hr (Silent)
7 I 24 Hr (Audiie)
CONSOLE PANIC. Onfy zone types 0.26.7.8.9
applicable.
O-Osec;1-2Osec;2-3osec;3~45sec
EXIT Delay = ENTRY Delay + 15 set
0 I 400 ms nominal; 1 I 10 ms nominal
(*40-•47)
‘40
PABX ACCESS CODE
Enter 4 digits, O-9. tf fewer than 4 digits entered, exit by
0000
pressing l (and press 41, if entering next field). To clear entries from field, press ‘40’.
l 41
PRIMARY PHONE No.
nnnnnmnnnnnn
9. Do not fill unused spaces. If fewer than 12 digits entered, exit by pressing
field). To clear entries from field, press ‘41’.
l
Enter up to 12 digits, O(and press 42. if entering next
‘42
SECONDARY PHONE No.
nnnnnnnnnnnn
Enter upto 12digitq O9. Do not fill unused spaces. N fewer than 12 digits entered, exit by pressing ’ (and press 43, if entering next
field). To clear entries from field, press ‘42’.
l 43
SUBSCRIBER ACCOUNT No.
Enter O-9; #+l 1 for 8; #+12 for C:#+l3
IIIIIII
for 0: #+14 for E; a+15 for F. If only 3 digits used, exit by pressing l (and press 44, if entering next field). To
clear entries from field, press ‘q3’.
Exmpks: For Acu No. 1234, enmr: 1’
121
m
14(
For Acct No. 8234, entar: ml
121
131
141
For Acct No. 123,enter: m
121
131
1’1
Enter ’ as the 4th diiit at ‘43 if 3+1 dialer reporting is to be used.
Cl
OP~+~,~+~ADEMCC~J~STANDARD
6 or u&fined = 4+2 ADEMCO EXPRESS
I= 3+ t ,4+1 RADICNICSSTANDARD
6 6 3+1.4+1 ADEMCO l.S EXPANDED
2 = 4+2 ADEMCO L’S STANDARD
9 = 3+1.4+1 RADIONICSEXPANDED
3 = 4+2 RADIONICSSTANDARD
l 44
REPORT FORMAT
l 45
PHONE SYSTEM SELECT
‘46
FUTURE USE
‘47
15 SEC DIALER DELAY (BURG) t 0
fl
0
t 0
ff Cent. Sta. IS NOT on a WATS line: 0 - Pulse Dial; 1 -Tone Dii
if Cent. Sta. IS on a WATS line: 2 I Pulse Dial; 3 = Tone Dial
Enter 0.
0 I no, 1 I yes
t~anumbero~thanOor1isentered,evennumben=sameasO;oddnumbers=~asl.
tt If a number greater than 3 is entered. the controi will rubtract multipie of 4 to get to the allowable program range.
41 lOPRV2 4192 (Sea Instructions N4926VS)
OVER*
‘TO PROGRAM ALARM,
SYSTEM STATUS, AND
RESTORE
REPORT CODES (‘51=74):
With a 3+1 or 4+1 Standard Format: Enter a code
in the fkf box: l-9.0. B. C, D. E, or F. Enter (#+lO] for 0.
p;]
for B, (#+12] for C. [#+13] for D, (#+14] for E. (#+15]
A (01 (not [#+lO]) in the first box will disable a report.
A [O] (not[#+lO]) in the secondbox will result in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in
bofh boxes (1st and 2nd digits) for l-9. 0, or B-F, as described above.
A [O] (not [#+lO]) in the second box will eliminate the expanded message for that report.
A IO] (norM+lOl) in both boxes will disable the report.
Exemplee: For Code 3 (Single Digit), enter: 131
-1
For Code 32 (Two Digits), enter: 131
12)
For Cc& 82 (Hexadecimal)enter: (m
ALARM
REPORT
CODES
RESTORE
RPT CODES
(‘70=74)
‘70
ALARM RESTORE RPT CODE
El
2nd digit is automatically sent as the 2nd
digit of the zone alarm report code
programmed in ‘51-‘59. if expanded or 4+2
reporting is selected.
‘71
TROUBLE RESTORE RPT CODE
11
‘72
BYPASS RESTORE RPT CODE
III
‘73
AC RESTORE RPT CODE
III
‘74
LOW BAT RESTCRE RPT CODE
n
DOWNLOAD
INFO
II
I1
(*94=97)
l 94
~AD~yyl.(
‘96
Enter up to 12 digits, O-9. Do not fill unused spaces.
If fewer than 12 digits entered, exit field by pressing
(and press 95, if entering next field). To clear entries from field, press ‘94’.
INfTlALQES DOWNLOAD ID, SUBSCRIBER
ACCOUNT No. FOR INfTlAL DDWNLOAD
No entry required.
ZEROS ALL PROGRAM FIELDS
No entry required.
r[
(*51=59)
,I
I,
I,
,I
I,
,
l
‘51
ZONE 1 ALARM REPORTCODE
mr[
‘52
ZONE2ALARMREPORTCODE
mr[
‘53
ZONE 3 AIARM REPORT CODE
m
‘54
ZONE4AlARMREPCRTCCDE
III1
‘55
ZONE5AlAFtMREPORTCODE
nII-1
‘56
ZONE6ALARMREPORTCODE
Tit-1
‘57
ZONE 7 ALARM REPORTCCDE
(Console Panic)
I-II]
rI
TO EXIT PROGRAM
‘59
STATUS
l 80
TFOUBLE REPORT CODE
III
‘61
BYPASS REPORT CODE
III
‘82
AC LOSS REPORT CODE
III
l 63
LOW BATREPORT CODE
nn
‘84
TEST REPORT CODE
III
‘65
OPEN REPORT CODE
El
‘66
RPT CODES
(‘SO-•66)
ttt
ttt
CLOSE REPORT CODE
I
m 2nd digii is automatically sent as the user
number ff expanded or 4+2 reporting is
selected.
4 11OPRVP4J92(See Instructions N4926V5)
MODE (‘98 or
Press ‘98 or ‘99 if exiting programming, or next field
number if continuing.
‘98
EXITS PROGRAMMING MODE and
Prevents m-entry by: Master Code + Code + 0.
EXTTS PROGRAMMING MODE and
‘99
aIows m-entry by: Master Code + Code + 0.
‘58
SYS
‘97
l 99)
* Continuadfrom Page 3
The Alarm. System Status and Restore Reporl Codes shown in
fields ‘Sl-‘74 in the following sections may be designated to
rapon to the central station in any of the above fats.
The 3+1 and 4+1 Standard formats comprise a 3 for 4)
digit subsczibernumber and a single diiit reporl code (e.g. Alarm.
Trouble, Restore, Open, Close).
The 3+1 and 441 Expanded formats comprise a 3 for 4)
digit subsaiber number, and a single digit report code, followed
by a second line where the report cada is repeated 3 (or 4) times
and followed by another number (normally the zone number) or
user ID related to that report
The 442 formats comprise a 4 digit subscriber number and
single digit report code. immediitety followed by the zone number
(nonally) or user ID.
3411441
3411441
4+2
-
AC Loss
=SS)T
=w 8
sss(S)
E
Lowaatl
=ev L
Bypass
S=(S) A
JWA) 2
ssso f
l-mnt
izgb”
sss(SlE
ssssbu
SSSSTt
‘52
-8b
-h
l 53
EWEI &
sss(S) L
LLLfu
La
-7-.
sss(s)O
ooo(O) u
sssoc
cccou
sss(s)G
ClOSe
Test
l 54
-4
‘55
-0i.f
l 58
SSSSCU
SsasPz
Lo8at Res.
-
-AA,
RLLB
Trouble Ftes.
-e
-R-T’
Bypass Res.
fv+ww
=-Rg
WWWW
-w
2s
Tt P
=
EABE=
LLB s
05
C=
U=
Gg =
-R=
RTt =
R8 b =
RAAC =
ALL 8 =
SubsuibarID
Alarm Code-1st digit
T~bcatI~ Zone Number--2nd diiit
Tiibk-code (1st a 2nd digitsj
Bypass Code (1st 6 2nd digits)
AC Loss Code (1st 6 2nd digits)
Low 8aUery Code(lrt 6 2nd digits)
Open Code-1st Digit
Close -1st
Dioit
UserNumber(lst~2nddigik)
Test Code I1 st 6 2nd diaik)
Restore C&e (Alarm)15 6.2nd digits
bslore Coda (TrM)l st 6 2nd digits
Restore Code (8yps)l st 6 2nd digits
Restore Code (AC) 1st 6 2nd digits
Restore Code (8at)lst 6 2nd diiik
‘Zone numbers for: [‘I 6 (#] = 7
Duress = 8
Tamper= 9
‘57
s86sGa
Resmre
A&ml
AC Restore
WllWtX
SSSorSSSS=
A=
TO PROGRAM
ALARM,
SYSTEM
STATUS,
AND
RESTORE REPORT CODES (Fields
‘51.‘74):
With a 3+1 or 441 Standard Format: Enter a code in the
first box: l-9, 0. B, C, D. E. or F. Enter (X+10] for 0, (#+ll] for 8,
[#+12] for C, [#+13] for D. [#+14] for E. (#+15] for F.
A (01 (not (#+lO]) in the fifsl box will disable a report.
A [0] (not [#+lO]) in the second box will resuli in automatic
advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both
boxes (1st and 2nd digits) for l-9,0, or B-F, es described above.
A (01 (not (W+lO]) in the second box will eliminate the expanded
message for that report.
A 101(not I#41 01) in both boxes will disable the report.
See examples on programming form.
SYSTEM STATUS CODES
ALARM REPORT CODES
(Fields l 60 - ‘66)
(Fields l 51 - *Se)
l 5 1 ZONE 1 ALARM CODE
‘60
TROUBLE
CODE
IOI 101
ZONE 2 ALARM
IOI (0 I
ZONE 3 ALARM
(0 I (0 1
ZONE 4 ALARM
CODE
‘61
!%!SS
CODE
l 62
!t&SS
CODE
‘63
CODE
I ‘64
CODE
‘65
ZONE 7 ALARM CODE
CONSOLE
PANIC
.- . .a .
l 66
(0I 10I
ZONE 5 ALARM
PIPI
ZONE 6 ALARM
IOI (0 I
’ CODE
CODE
IOI (0 I
LO BAT CODE
p&]
RPT CODE
ii&i!
RPT CODE
(0 ] (2nd digit I User (I)
CLOSE RPT CODE
(0 ] (2nd digit - User #)
‘58
ZONE 8 ALARM CODE
I”
DURESS
1 1” 1
10 110 1
I
‘59
iONE 9 ALhFiti ‘CODE
TAMPER
[O ] (0 ]
(Fi Id ‘70 - -74)
‘70
ALARM RESTORE RPf :O:E
IS1 DIGIT
101(2nd dinit normaflv zone 61 When set to 0. all restores are
b&&d.
The 2nd dii of an alarm restortz-2 digif report is the
same as the 2nd digit of the alarm repoti being restored as
found in fields ‘51. ‘59.
‘71 TROUBLE
RESTORE CODE
(01 (01 ff the 1st digit is sel to 0. reporting is disabled. Trouble
restore is reported only if a//troubles in the system are restored.
‘72
BYPASS
RESTORE CODE
(01 (01 ff the 1st digit is set to 0, reporting is disabled.
l 73 AC RESTORE RPT CODE
(01 (0] if the 1st digit is set to 0. reporting is disabled.
l 74 LO BAT RESTORE CODE
(01 (01 If the 1st digit is set to 0, reporting is disabled.
DOWNLOAD INFORMATION
(*94-•97)
l 94 DOWNLOAD PHONE NUMBER
[ I[ I[ I[ Ii II II I[ I[ I! I[ II I
‘96
l 97
TO
‘98
‘99
-9-
Enter up to 12 digits: O-9. Do not fill unused spaces. End field
by entehng ’ if not filled. To clear entries from iield, press ‘94’.
INITIALIZES
DOWNLOAD
ID AND SUBSCRIBER
ACCT. No. FOR DOWNLOADING
(No entry required)
ZEROES AU PROGRAM FIELDS (No entry required)
EXIT PROGRAM MODE p96 or l 99)
Press ‘98 or ‘99 if exiting programming, or next field
number if continuing.
EXITS PROGRAMMING
MODE and
prevents
re-entry by: Master Code + Code + 0.
EXITS PROGRAMMING
MODE and
allows
re-entry by: Master Code + Code + 0.
PROGRAMMINGFORM
4110
FIELD
SYSTEM
FUNCTION
ARMING
PROGRAMMED
VALUES
Enter 4 digits, O-9
‘20
MASTER SECURflY CODE
‘21
OulcK ARM ENABLE
+I30
-no,
1 -yes
‘22
KEYSWITCH ENABLE
+I3
rno.l
-yes
FORCED BYPASS ENABLE
+I30
-no,1
-yes
‘23
ZONE
RESPONSE
.OclclU
PROGRAMMING
++q
q
‘30
AlARMBELLnMEoUT
‘31
ZONE 1 RESPONSE TYPE
‘32
ZONE 2 RESPONSE TYPE
cl
‘33
ZONE 3 RESPONSE TYPE
cl
‘34
ZONE 4 RESPONSE lYPE
cl
'35
ZONE 5 RESPONSE TYPE
cl
'36
ZONE 6 RESPONSE TYPE
El
'37
ZONE 7 RESPONSE TYPE
'38
ENTRY DELAY
cl
++ c]
‘39
ZONE3RESPONSETOOPEN
DIALER
i7
(‘20~~23)
PROGRAMMING
+
q
(‘29=39)
O=n0na;l
=4min;2-8min,3-12min
ZONE TYPES FOR PROGRAYUING FIELDS VI-37
0 (or undefined) = Zone Disabled
1 I ENTRY/EXIT. Burglary
2 I FIRE with timeout
3 - PERIMETER Burglary
4 I INTERlOR/FOLLOWER. Burglary
5 - TROUBLE BY DAY/ALARM BY NIGHT, Burglary
6 I 24 Hr (Silent)
7 I 24 Hr (Audiie)
8 I 24 Hr (Auxiliiry)
9 I FIRE without timeout (Fields ‘35 and ‘37 only)
CONSOLE PANIC. Only zone types 0,2,6,7,8.9
applicable.
0=0sec,;1=20sec;2=30sac;3=45sec
EXIT Delay = ENTRY Delay + 15 sac
0~400msnominal;1=10msrmminal
(*40-•47)
l 40
PABX ACCESS CODE
Enter 4 digits. O-9. ff fewer than 4 digits entered. exit by
cl0cl0
pressing l (and press 41, if entering next field). To clear entries from field, press ‘40’.
‘41
PRIMARY PHONE No.
nnnnnnnnnnnn
9. Do not fill unused spaces. ff fewer than 12 digits entered, exit by pressing
fiild). To dear entries fmm fiifd, press ‘41’.
l
Em upm 12dWs. O(and press 42, if entering next
SECONDARY PHONE No.
nnnnnnnnnnnri
9. Do not fill unused spacxts. H fewer than 12 digits entered, exit by pressing
field). To dear entries from field, press ‘42’.
l
Enterupml2dk$s,O(and press 43, if entering next
l 42
‘43
Enter O-9; 6+11 for 8; kl2 for CM13
SUBSCRIBER ACCOUNT No.
OOIIII
for D; 6+14 for E; #+15 for F. If only 3 diiits used, exit by pressing ’ (and press 44. if entering next field). To
dear entries from field. press ‘43’.
Exmpkw: For Accl No. 1224. enter: LT
121
131
14(
For Acu No. 8234. enter: )
‘44
REPORTFORMAT
121
131
141
For ~cct No. 123, enter: 1-i-l
121
m
1’1
Enter l as the 4th digit of ‘43 if 3+1 dialer reporting is to bs used.
cl
6or-=4+2ADEMCOEXPRESS
0 = 3+1. kl ADEMCO Us STANOAR
6 I 3+1.4+1 ADEMCO U8 EXPANDED
1 - 3+1.4+1 R4DIoNlcs STANDARD
9 = 3+1, kl RADIONICSEXFANDED
2=4+2AoEMcoussTANDARo
3 - 4+2 RADIONICS srANMRo
fi
OH
l 45
PHONE SYSTEM SELECT
‘46
FUTURE USE
'47
15 SEC DLALER DELAY (BURG) + 0
+ 0
Cent.Sta. ISNOTona
WATS line: 0 -PulseDial;
1 -ToneDi
If Cent. Sta. IS on a WATS fine: 2 I Pulse Dii, 3 I Tone Dial
Enter 0.
0 = no, 1 I yes
RESTORE
TO PROGRAM
ALARM,
SYSTEM STATUS, AND’
RESTORE
REPORT CODES (‘51-‘74):
Wlth a 3+1 or 4+1 Standard Format: Enter a code
in the first box: l-9.0. B, C, 0, E, or F. Enter [#+lO] for 0,
[#+ll] for B. [#+12] for C, [#+13] for 0, [#+14] for E, (r&15]
for F.
A IO] (not [#+lO]) in the f&box will disable a report.
A [O] (nor [#+lO]) in the secondbox will result in automatic
advance to the next field when programming.
Wlth an Expanded or 4+2 Format: Enter codes in
both boxes (1st and 2nd digits) for 1-9, 0, or B-F. as described above.
A [O] (nor [#+lO]) in the second box will eliminate the expanded message for that report.
A (01 (nor f#+lOl) in both boxes will disable the report.
Fl
Examples: For Code 3 (Single Diiit). enter: v1
ALARM
For Code 32 (Two Diiits). enter: l-
1-2
For Code 82 (Hexadecimal) enter: [m
121
REPORT
CODES
RPT CODES
(*70=74)
‘70
AIARM RESTORE RPT CODE
El
2nd digit is automatically sent as the 2nd
digit of the zone alarm report code
programmed in ‘51-X9, if expanded or 4+2
reporting is selected.
‘71
TROUBLERESTORERPTCOOE
Ilr[
‘72
BYPASS RESTORE RPT CODE
III
‘73
AC RESTORE RPT CODE
III
l 74
LOWBATRESTORERPTCOM
mr[
DOWNLOAD
l 94
INFO
(+94=97)
DOWNLOAD PHONE No.
qEntercloonnclclcllJocl
UP
to 12 digits, O-9. Do not fill unused spaces.
(‘51-‘59)
ff fewer than 12 diiits entered, exit fiefd by pressing
(and press 95. if entering next field). To clear entries from field, press ‘94’.
lNlTlALlZES DOWNLOAD ID, SUBSCRfBER
ACCOUNT No. FOR INflTAL DOWNLOAD
No entry required.
ZEROS ALL PROGRAM FIELDS
No entry required.
l
‘51
ZONE 1 AJARM REPORTCODE
mrj
‘52
ZONE2AlARMREPOFlTCODE
mr1
‘53
ZOf’IE3ALARMREPORTCODE
mr(
‘97
‘54
ZONE4ALAJ?MREPORTCODE
III1
TO EXIT PROGRAM
[rl[
Press ‘98 or ‘99 ff exiting programming, or next field
number if continuing.
‘55
ZONE5AlARMREFORTCODE
‘56
ZONE6AfARMREPOfTrcoDE
‘57
ZoNE?kuAlwREPoKrcoDE
(Console Panic)
‘56
ZoNE8ALARMREPoRTcQDE
(Duress)
1111
‘59
zmEg~~-y=)
III
SYS
STATUS
‘60
TROUBLEREPORTCODE
III
‘61
BYPASS REPORTCODE
III
‘62
AC LOSS REPORT CODE
ElII
‘63
LOW BAT REPORT CQDE
III
‘64
TESTREPORTCQDE
III
‘65
OPENREPORTCODE
I
*
‘86
RPT
CODES
‘96
IlI[
Ill]
‘98
‘99
(*60-‘66)
ttt
ttt
CLOSE REPORT CODE
I
m 2nd diit is automatically sent as the user
number if expanded or 4+2 reporting is
selected.
-ll-
MODE (‘98 or
U(fT5PROGRAMMlNGMODEand
preVenrs reentry by: Master Code + Code + 0.
EXRS PROGRAMMING MODE and
aUows reentry by: Master Code + Code + 0.
l QQ)
TESTING THE SYSTEM
After installation is completed, the Security System
should be carefully tested.
1. With the System in the disarmed state, check
that all zones are intact. If NOT READY is displayed, press the r] key to display the faulted
zone(s). Restore faulted zone(s) if necessary, so
that READY is displayed. Fauff and restore every sensor individually to assure that it is being
monitored by the system.
2. Enter the security code and press the TEST
key. The external sounder (if used) should
sound for 1 second and then turn off each time a
contact is faulted. A test report should be transmitted (if programmed) to the Central Station immediately. If the backup battery is discharged or
missing, the external sounder.will not turn on
and a LOW BATTERY report will be transmitted
instead of a TEST report. The keypad will beep
once per minute to indicate that the system is in
the Test Mode.
3. Battery Test: For UL Listed Household
fire/burglary installations, a Battery Test Switch
(Ademco No. 1206) must be installed next to the
Control, so that the system’s backup battery can
be tested periodically (at least weekly). To test
the battery, enter test mode as described in step
Alann messages will be sent to the central
station during the following tests 4 8 5. r”,
i.,, ;;
Notify them that tests will be in progress.
4. Arm the system and fault one or more zones.
After 15 seconds (if optional dialer delay is selected), silence afarm sounder(s) by entering the
code and pressing OFF. Check Entry/Exit delay zones.
5. Check the keypad-initiated alarm by pressing the
Panic key pairs - r] and [#I. If the system has
been programmed for audible emergency, the
console will emit a steady alarm sound, and
ALARM and 07 will be displayed. Silence the
alarm by entering the security code and
pressing OFF.
If the system has been programmed for silent
emergency, there will be no audible alarms or
displays, but a report will be sent to the central
station.
6. Notify the central station that all tests are finished, and verify results with them.
Note: If the battery standby capacity is exceeded
during an AC power failure, the 4110 will automatically shut itseff off.
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user
are vital to continuous satisfactory operation of any
alarmsyStem.
The installer should assume the responsibility of developing and offerfng a regular maintenance program
to the user as well as acquainting the user with the
proper operation and limftatiins of the alarm system
and its component parts. Recommendations must
be included for a specific program of frequent testing
(at least weekfy) to insure the system’s proper operation at all times.
2 above and check that the POWER LED is on,
indicating the presence of AC power in the
system. Momentarily depress the Battery Test
Switch. If the battery is operational, the POWER
LED will go out, but the system will remain in the
Test mode. If the battery is weak, or not present,
the system will reset and the console will display
“df’. To restore the system, and silence any
beeping, enter the security code and press the
OFF key.
c----l
i
ACCESSORIES
No.
No.
BRK
No.
No.
No.
No. 4116
1321rTFP
16.5VAC 25VA Plug-In Transformer (U.S.A. installations).
1321CN
16.5VAC 25VA Plug-In Transformer (Canadianinstallations).
PA400B
Piezoelectric Alarm Sounder,
90dB output (mounts in singlegang box).
702
Self-contained 20 watt Siren
(indoor or outdoor).
740
Extremely loud Piezoelectric
Alarm Sounder, 122dB output
(indoor or outdoor).
411 OPRVP ProgrammingForm (Pkg of 50)
No.
BRK
BRK
BRK
also:
-12-
Tampered Single LED Remote
Station (Arming/DisarmingKeyswitch). NO7E: Obtain Lo&switch separately (Ademo No.
2774-70. 40%70, 014005-70).
1206
Battery Test Switch (N.C.Momentary)
Requiredfor UL Installations
1412
4-wfre fonfzation Products of
Combustion Detector
2412
4-wire Photoelectric Smoke
Detector
2412TH
4-wire Photoelectric Smoke
Detector w/l35OF (57%) Heat
Detector
Nos. 4127, 4137, and 5330
(see SPECIFICATIONS on next page).
f----I
4110 SECURfTY CONTROL
l.Physlcal:
12-l/2” (318mm)W
14-l/2” (368mm)H
3” (78mm)D
2. Electrical:
VOLTAGE INPUT: 16.5VAC from plug-in 25VA
transformer, Ademco No. 1321ITF2. (in U.S.A.).
Note: For Canadian installations, a’ No. 1321CN
transformer must be used.
RECHARGEABLE BACK-UP BATTERY: 12VDC
4AH (Gel type)
ALARM SOUNDER: 10.5-l 3.8V, P.OAmp output
can drive 12V BELLS or can drive one or two 702
(serles connected) self-contained 20-watt sirens.
Do not connect two 702s in parallel.
AUXILIARY POWER OUTPUT: 10.5-13.8VDC,
5OOrnAmax. fnterrupts for smoke detector reset.
Note : For UL installations, Alarm Sounder plus
Auxiliary Power currents should not exceed
600mA.
STANDBY TIME: 4 HRS with Auxiliary load of 5OOmA
(using 4AH battery).To determine total standby
battery load, add 1OOmAto total Aux. power output
and remote console currents.
FUSES: Battery (3A) No. 90-12
Sounder (2A) No. 90-2
3: Communlcatlon:
FORMATS SUPPORTED:
Ademco Express, 10 characters/set, DTMF
(TouchTone) Data Tones, 1400/2300Ht ACK,
1400Hz KISSOFF
Ademco Low Speed, 10 pulseslsec, 1900Hz
Data Tone, 1400Hz ACKMISSOFF
Radionlcs/SESCOA, 20 pulses/sec.l8OOHz
Data Tone, 2300Hz ACfUKISSOFF
Can report O-9,B-F
Line Seize: Double Pole
Ringer Equivalence: 0.08
FCC Registration No.: AC 398U-68192-AL-E
4127 REMOTE CONSOLE
1. Physlcal: 5-518’ (143mm)W
4-11/16’ (119mm)H
718’ (22mm) D
2. Electrical: Voltage Input: 12VDC
Current Drain: 20mA
3. Interface Wlrlng:
RED:
12VDC input (+) aux pwr
GREEN: Data Out to Control
YELLOW: Data In from Control
BLACK: Ground
4137 REMOTE -CONSOLE
1. Physlcal: 8-2/5’ (213mm)W
4-314’ (121mm) H
l-1/10”
(28 mm) 0
2. Electrlcal: Voltage Input: 12VDC
Currht Drain: 60mA
3. Interface Wiring:
RED:
12VDC input (+) aux pm
BLUE:
18VDC input from optional
No 1350 or 1360 Power Pack
GREEN: Data Out to Control
YELLOW: Data In from Control
BLACK: Ground and (-) connection from
optional No. 1350 or 1360 Power
Pack
6330 REMOTE ALPHA CONSOLE
(Seiecl Vector Device)
1. Physlcal: 7-3/4” (197mm)W
4-7116” (113mm)H
l-114’ (32mm)D
2. Electrlcal: Voftage Input: 12VDC
Current Drain: ,105mA
3. Interface Wlrlng:
RED:
12VDC inpuf (+) aux pwr
GREEN: Data Out to Control
YELLOW: Data In from Control
BLACK: Ground
-13-
I
WARNING
THE LIMITATIONS OF ‘THIS ALARM SYSTEM
I
While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or
other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a
variety of reasons. For example:
Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing devices will not work
without power. Battery-operated devices will not work without batteries, with dead batteries, or if the batteries are not put in
properly. Devices powered solely by AC will not work ff their AC power supply is cut off for any reason, however briefly.
. A user may not be able to reach a panic or emergency button quickly enough.
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate
or provide earfy warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal
Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work
are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires
that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed
doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for
example, may not sense a first floor or basement fire. Finally, smoke detectors have sensing limitations.
No smoke
detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by
carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable
materials, overloaded electrical circuits, chiklren playing with matches, or arson. Depending on the nature of the fire and/or
bcation of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow
all occupants to escape in time to prevent injury or death.
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation
manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection,
and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion
that takes piace behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows.
Mechanical
tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can
reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient
temperature of the protected area approaches the temperature range of 90” to lSO”F, the detection performance can
decrease.
Afarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers ff they are bcated on the
other side of cbsed or partly open doors. tf warning devices are located on a different level of the residence from the
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not
hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliance, or by passing traffii.
Finally, afarm warning devices, however bud, may not warn hearing-impaired people.
9 Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or
temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
9 Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond
appropriately.
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to
last as bng as 20 years, the electronic components could tail at any time.
The most common cause of an afarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This
alarm system should be tested weekly to make sure all sensors are working properly. The security console (and remote
keypad) should be tested as well.
Installing an alarm system may make the owner eligibie for a lower insurance rate, but an alarm system is not a substitute for
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue
to insure their lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe it to themsefves and their loved
ones to learn about these developments.
:‘g,
\
l
l
l
l
-7
‘..
l
.!1 ..
-14-
!
CANADIAN
DEPARTMENT
OF COMMUNICATIONS
(DOC) STATEMENT
NOTICE
The Canadian Department of Communications label identifies certified equipment. This certification means that
the equipment meets certain telecommunications network protective, operational and safety requirements. The
Department does not guarantee the equipment will operate to the user’s satisfaction.
iBefore installing this equipment, users should ensure that it is permissible to be connected to the facilities of the
IloCal telecommunications company. The equipment must also be installed using an acceptable method of
iconnection. In some cases, the company’s inside wiring associated with a single line individual service may be
~extendedby means of certified connector assembly (telephone extension cord). The customer shouM be aware
‘that compliance with the above conditions may not prevent degradation of service in some situations.
‘Repairs io certified equipment should be made by an authorized Canadian maintenance facility designated by the
1supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the
telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the elect&al ground Wnnections of the power utility, telephone
lines and internal metallic water pipe system, if present, are connected together. This precaution may be
particularlyimportantin rural areas.
Caution: User should not attempt to make such connections themselves, but should contact the appropriate
electric inspection authority,or electrician, as appropriate.
The
(LN) assigned to 8aCh t8rminal device d8nOt8S the percentage of the total load to b8
Wnn8Ct8d to a telephone loop which is used by the device, to prevent overloading. The termination on a loop
may consist of any combinationof devices subject Onlyto the requirementthat th8 total of the Load Numbers of all
the devices does not exceed 100.
AVIS
L%tiquette du ministr&e des Communications du Canada identifie le mat&f81 homologri6. Cette Btiquette Wrtiiie
‘que le materiel est conforme a cettaines normes de protection, d’exploitation et de s&urit6 des rdseaux de
t&~communications. Le minister8 n’assure toutefois pas que I8 mat&i81 fonctionnera a la satisfaction de
I’utilisateur.
Avant d’installer c8 mat&iel, l’utilisateur doit S’aSSur8rqu’il eSt permis de I8 racwrder aux installations de
Pentrepriselocale de t6l6wmmunication. Le matMel dolt 4galement &re install6 en suivant une method acceptde
,de raccordement. DanS CertainScas, l8S filS iftt&ieUrS de I’8I’Itr8priS8utilis& pour un ~8rvic8 individuel a lign8
‘Unique p8UVent 8tr8 prOlOng& au moyen d’un diSpOSitifhomologu4 d8 raCWrd8ment (cordon prolongateur
lt&phOniqtJ8 iM8m8). L’abonne ne dOit pas OUbli8rqU’il8St possible que la WIIfOrmit~ aux Wndiiions honch
Ici-dessus n’empechent pas la degradation du sefvtce par certaines situations. ACtUellem8nt,les enterprises de
~t6l4wmmunication ne permettent pas’que I’on raccorde leur mat&i81 aux jacks d’abonn~s, sauf dans l8s cas
~precis p&us par les tarrifs patticuliars de ces entmprises.
ales reparations de mat&i81 homologue doivent &re 8ff8ch~~8spas un centre d’entretien canadien authoris4
idesign par le fOUmiSSeUr.
La wmpagnie de t~l6wmmunications p8ut demander a l’utilisateur de debrancher un
iappareil a la suite de reparations ou de modifications effectu68s par l’utilisateur ou a cause de mauvais
jfonctionnement.
‘Pour sa propre protection, I’utilisateur doit s’assurer que tous 18sfils de mise B la terre de la sourc8 d’energie
6lectriqu8, d8S lign8SM6phOniqU8Set des CanaliSatiOnS
d’eau m&alliqU8S,S’il y en a, Wnt racWrd& ensemble.
Cette p&caution es1particuli~rementimportante dans les r4gions rurales.
tAvertissement: L’utilisateur ne doit pas tenter de fair8 ces raccordements l&m&me; il doit avoir rewurs B un
~service d’inspection des installations 6lecttiques. ou & un &ctrician, selon le cas.
,* .
w(lC)
assign4 a ChaqU8dispositif terminal pour 6vtter toute surcharge indique le pourcentagede
ila charge tOtalequi p8ut &re t’aCWtde6a un circuit t6l6phOniqueboud6 utilis6 par ce dispositif. La terminaisondu
Icircuit boucl6 peUt &re COnStitU68de n’imporle quell8 WmbinaiSOnde dispositifs, pourvu que la somme des
iindices de charoe de I’ensembledes dispositifs ne depasse Pas 100.
-15-
COMMUNICATIONS
1This equipment FEDERAL
has been tested to FCC requirements
COMMISSION
(FCC)
STATEMENT
and has been found acceptable for use. The FCC requires the following
statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance
with the manufacturer’s instructions, may cause interference to radio and television reception. ft has been type tested and
found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules,
which are designed to provide reasonable protection against such interference in a residential installation. However, there is
no guarantee that interference will not occur in a particular installation. ff this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment off and on. the user is encouraged to try to correct the
interference by one or more of the foffowing measures:
.
lf using an indoor antenna, have a quality outdoor antenna installed.
l
Reorient the receiving antenna until interference is reduced or eliminated.
.
Move the radii or television receiver away from the receiver/control.
.
Move the antenna leads away from any wire runs to the receiver/control.
.
Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch
circuits.
If necessary, the user should consult the dealer or an experienced radionelevision technician for additional suggestions. Ths
user or installer may find the following booklet prepared by the Federal Communications Commission helpful:
‘Interference Handbook.
This booklet is available under Stock No. 004-000-00450-7 from the U.S. Government Printing Off& Washington, DC 20402.
The user shall not ma&e any changes or modifkatbns to the equipment unless authorized by the Instalktkw Instructions OI
Usefs Manual. Unauthotized changes or modifkzations could void.the user’s authority to operate the equloment.
IAlarrn
ADEMCO
LIMITED
WARRANTY
I
Device Manufacturing
Company, a Division of Piiay Corporation, and its divisions, subsidiaries and affiliates (‘Sellef), 165 Eileen Way, Syosset, New York 11791, warrants its products to be in conformance with its own
plans and specifications and to be free from defects in materials and workmanship under normal,use and senrice
for 16 months from the date stamp wntrol on the product or, for products not having an Ad8mW date stamp, for
12 months from date of original pUChaS8unless th8 iWtallatiOn iWtNCtiOnSor Wtakig Sets forth a Shorter period,
in which case the shorter period shall apply. Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product which is proved not in compliancewith Sellers specifiions
or prOV8Sd8f8ChV8in materials or workmanship under normal use and service. Selier shall have no obligation under this Limited Warranty or otherwise if the product is altered or improp8rly repaired or serviced by anyone other
than Ad8mW factory service. For warranty service, return product transportation prepaid, to Ademco Factory
Service, 165 Eileen Way, Syosset, New York 11791.
THERE ARE NO WARRANTIES,
EXPRESS
OR IMPLIED, OF MERCHANTABILITY,
OR FITNESS
FOR A
PARTICULAR
PURPOSE
OR OTHERWISE,
WHICH EXTEND BEYOND THE DESCRIPTION
ON THE FACE
HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL
OR INCIDENTAL
DAMAGES
FOR BREACH OF THIS OR ANY OTHER WARRANTY.
EXPRESS OR IMPLIED. OR UPON ANY
OTHER BASIS OF LIABILITY WHATSOEVER,
EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLERS
OWN NEGUGENCE
OR FAULT.
I
I
Seller do8S not represent that the pIoduCtStt Sells may not be WmprOr’niWdOr circumvented: that the prOdUCtS
will prevent any personal injury or property bss by burglary, robbery, fire or otherwise; or that the products will in all
cases provide adequate warning or protection. Customer Und8rStandSthat a properly installed and maintained
alarm may only reduce the risk of a burglary, robbery, fir8 or other events occurringwithout providing an alarm, but
it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a
result. CONSEQUENTLY,
SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL
INJURY, PROPERTY
DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER,
IF
SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY,
FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY
OR OTHERWISE,
REGARDLESS
OF CAUSE OR ORIGIN, SELLER’S MAXIMUM
LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE
THE COMPLETE
AND EXCLUSIVE
REMEDY AGAINST SELLER. This warranty replaces any previous warranties
and is the only warranty made by Seller on this product. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.
‘%DEMCOj
ALARM DEVlCE MANUFACTURING CDA UUSlCPJ
OFUKWAY COFPCRATfoN
165 Eileen Way, Syosset, New York 11791
Cowrioht
N4926V5
4/92