HEATSHRINKABLE SHEETS
Transcription
HEATSHRINKABLE SHEETS
Fip fip HEATSHRINKABLE SHEETS Manufacturer Statement & Product data Sheets This Section includes the Technical data sheets, safety Data Sheets, and Installation Instructions. Fip g Kits Drillin l a n io Direct TBK ts oduc r P p i h Flags -CPS CANUSA -CPS CANUSA e™ saTub Canu e™ Sleev id Wrap ucts uperCase d o r P S ted a CFS l u s n Pre-I SUPERS 10 INR-1 ts roduc P e n e l propy y l o P GTS & al A-CPS CANUS E GTS-P A-CPS CANUS 5 GTS-6 0 GTS-8 T GTS-H P-100 GTS-P P P GTS LRKN WLOX PMO/ Offseh™ ev id Sle Wrap s Sleeve b a h e R CA Fit Snap g n i s Ca CSK) (CSF/ ducts MIS o r P ore S-PP GT SA-CPS CANU SA-CPS CANU A-CPS CANUS eves ink Sle r h S h Hig PMA F /PMO KLOX GT SVE NU PS W W rap ra id pi Bo d Co nd™ at ™ HIELD AQUA-S HIELD AQUA-S A-CPS CANUS VE Co ati ng s SA -C ducts o r P eline p i P r Wate ts Produc r i a p e Re Pipelin ™ e d Tap Wrapi CPS CANUSA- CO HCA/H Melt Stick Mastic Filler CPS CANUSA- CRP ts duc o r P y x id Epo Liqu HIELD AQUA-S APD-NA-rev024 -FF AQW AQW PLX CSC-X se Super A-CPS CANUS CSS CSS-2 CSC CANUS A-CPS -CPS CANUSA CSS -CPS CANUSA CSS S SA-CP CANU CSS-2 -CPS CANUSA CFS CFS SUPER S A-CPS EAL CPS CANUSA-SEAL A-CP CANUS CANUS p™ saWra Canu P TBK-P TBK ld™ -Shie Aqua E HBE-F 5 de ra HBE-B9 rush G T e HBraEd-e H Brush Grad Spray G rade Spray G Canusa is registered to ISO 9001:2008. Product Data Sheet CanusaWrap™ Two-piece protective bulk roll with separate closure Canusa-CPS is a leading manufacturer of specialty pipeline coatings which, for over -CPS CANUSA 30 years, have been used for sealing and corrosion protection of pipeline joints and other substrates. Canusa high performance products are manufactured S SA-CP CANU to the highest quality standards and are available in a number of configurations to accommodate your specific project acking Black B applications. Product Description CanusaWrap™ is a wraparound sleeve with a separate closure designed for corrosion protection of buried and exposed steel pipelines. CanusaWrap™ is supplied in bulk rolls consisting of a crosslinked polyolefin backing, coated with a protective heat activated adhesive. Once installed, the system effectively bonds and protects steel substrates and common main line pipe coatings including polyethylene and fusion bonded epoxy. Features & Benefits Long-Term Corrosion Protection CanusaWrap™ provides excellent resistance to cathodic disbondment resulting in effective long term corrosion protection. The high performance crosslinked backing, in combination with a broad range of adhesives, can be engineered for regular or high stress environments. Once installed, CanusaWrap™ provides the structural integrity of a seamless tube, and provides the substrate with durable protection against abrasion and chemical attack. Yellow Flexibility on the Job Site Since CanusaWrap™ is supplied in bulk rolls, just-in-time customized lengths can be quickly cut in the field to protect any pipe size. This flexibility results in reduced inventories and cost savings on the job site. CanusaWrap™ is also available in a high shrink ratio for high profile joint protection. Consult the High Shrink data sheet or your Canusa representative for additional information. Easy Field Installation CanusaWrap™ can be installed quickly and easily in most environments. Since no special taping, priming or operator equipment is required, product installation is quick and labour costs are kept to a minimum. CanusaWrap™ and the closure seals are available in yellow with a thermochromic indicator and a patented Windoweld feature which visually confirms optimum installation. ng Backi Applications Oil & Gas Water Pipelines Polypropylene Pre-Insulated Pipes Girth-Weld Joints Configurations CanusaWrap™ 2-Layer Standard Shrink Pipe Sizes 55 - 1520 (2” - 60”) Temperature Range up to 80°C (176°F) CANUSA-CPS is registered to ISO 9001:2008. CanusaWrap™ The product selection chart shown here is intended as a guide for standard products. Consult your Canusa representative for specific projects or unique applications. The following are typical values based on Black, Heavy Duty (L) Sleeves. Sleeve Operating Characteristics Product Selection Guide Pipeline Operating Temperature Choose your sleeve based on Operating Temperature and Characteristics listed below. Celsius Fahrenheit 110° 230° 90° 194° 70° 158° 50° 122° 30° 86° WLG WTG -40°C Minimum Installation Temperature °C (°F) Resistance to Circumferential Forces Resistance to Soil Stress Resistance to Axial Pipe Movement Main Line Coating Compatibility Mastic Adhesives WLS WLO WLON WTS WTO WTON WLC WTC -40°F -40°C 60 (140) 65 (150) 75 (167) 75 (167) 90 (195) 60 (140) 90 (195) fair fair good good good good v. good excl fair fair good good good good v. good excl fair fair good good good good v. good excl PE, PP, FBE PE, FBE PE, FBE PE, PP, FBE, PU, Coal tar, Bitumen, Adhesive Backing Sleeve * For higher temperature requirements refer to Canusa GTS product line. Test Standard Unit Softening Point ASTM E28 °C (°F) Lap Shear DIN 30 672 M N/cm2 (psi) Specific Gravity ASTM D792 Tensile Strength ASTM D638 MPa (psi) Elongation ASTM D638 Hardness ASTM D2240 Abrasion Resistance 100 (212) 90 (194) 77 (171) 102 (216) 102 (216) 124 (255) 72 (162) 90 (194) 8 (12) 30 (44) 40 (58) 40 (58) 40 (58) 52 (75) 60 (87) 117 (170) .93 .93 .93 .93 .95 .95 .93 .93 20 (2900) 20 (2900) 20 (2900) 24 (3480) 24 (3480) 24 (3480) 20 (2900) 24 (3480) % 600 600 600 700 700 700 600 700 Shore D 46 46 46 48 52 52 46 48 ASTM D1044 mg 45 45 45 35 30 30 45 35 Volume Resistivity ASTM D257 ohm-cm 1017 1017 1017 1017 1018 1018 1017 1017 Dielectric Voltage Brkdwn. ASTM D149 kV/mm 27 20 20 27 20 20 20 27 Impact * DIN 30 672 class C -- pass pass pass pass pass pass pass Indentation * DIN 30 672 class C -- pass pass pass pass pass pass pass Peel ASTM D1000 N/cm (pli) 15 (9) 55 (31) 79 (45) 80 (46) 80 (46) 115 (66) 50 (29) 120 (70) Peel DIN 30 672 N/cm (pli) 8 (5) 50 (29) 70 (40) 65 (37) 65 (37) 90 (51) 35 (20) 86 (50)** Cathodic Disbondment ASTM G8 mm rad 6 6 8 8 7 7 13 11 Water Absorption ASTM D570 % 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 Low Temp. Flexibility ASTM D2671C °C (°F) -40 (-40) 5 (23) -20 (-4) -14 (7) -14 (7) -15 (5) -32 (-26) -28 (-18) -- -- -- C30 C30 -- C50 C50 -- DIN Approval * DIN 30 672 Fully Recovered T Sleeve Thickness class mm (mils) 2.5 (99) 2.3 (90) Fully Recovered L Sleeve Thickness mm (mils) 3.3 (131) 2.8 (111) -3.3 (131) * Denotes L sleeve thickness** backing elongation during peeling due to superior bond strength How To Order: Dimensions & Ordering Info -40°F 50 (122) Typical Product Properties 1 Hot Melt Adhesives WLA WLAS WLNN WTNN WLO-B 450-30 BK Bulk Roll Ordering Options Heavy Duty Thickness (L) Regular Thickness (T) BK-Black, YE-Yellow ²Colour 300, 450, 600, 900mm, (12, 18, 24, 36”) Sleeve / Closure Width CLH-B XXX-15 BK Hot Melt Closure CLS-B 100-15 ZZ Butyl Adhesive Closure ZZ-BK, WW, YE BK ZZ-BK, YE Bulk:15,30 m (50,100 ft) Precut: 300,450,600,900mm, (12,18,24,36”) 15, 30 m (50, 100 ft) Bulk Roll Length Closure Seal Options CLW-B 100-15 ZZ Weldable Closure 100mm (4”) 115, 150mm (4,6”) B - Bulk Roll designation Bulk Roll Designation 100mm (4”) B - Bulk Roll Adhesive (thickness as supplied) 1.7 mm (65 mils)¹ 1.25 mm (50 mils)¹ W- n/a H-0.35mm (14mils) S-0.75 mm (30mils) Backing (thickness as supplied) L - 0.9 mm (36 mils) T - 0.6 mm (25 mils) 0.65mm (27 mils) 0.6mm (32 mils) 0.8mm (32 mils) W - Bulk Roll Configuration C - Closure Seal NN has an adhesive thickness of 1.1mm (45 mils) Bulk Roll Lengths: up to 600 mm width: 30 m (100ft), above 600 mm width: 15 m (50ft) The above represents standard ordering options Consult your Canusa representative for any unique project requirements, including pre-cut sleeves or closures. ² WTON, WLON, WTNN, WLNN are available in black only. www.canusacps.com Canada U.S.A./Latin America Europe/Middle East Asia/Pacific CANUSA-CPS a division of SHAWCOR LTD. 25 Bethridge Road Rexdale, Ontario M9W 1M7, Canada Tel: +1 (416) 743-7111 Fax: +1 (416) 743-5927 CANUSA-CPS a division of SHAWCOR INC. 2408 Timberloch Place Building C-8 The Woodlands, Texas 77380, U.S.A. Tel: +1 (281) 367-8866 Fax: +1 (281) 367-4304 CANUSA-CPS a division of Canusa Systems Ltd. Unit 3, Sterling Park Gatwick Road Crawley, West Sussex England RH10 9QT Tel: +44 (1293) 541254 Fax: +44 (1293) 541777 CANUSA-CPS a division of SHAWCOR LTD. #05-31, Blk 52, Frontier Ubi Avenue 3 Singapore 408867 Tel: +65-6749-8918 Fax: +65-6749-8919 Canusa warrants that the product conforms to its chemical and physical description and is appropriate for the use stated on the installation guide when used in compliance with Canusa’s written instructions. Since many installation factors are beyond our control, the user shall determine the suitability of the products for the intended use and assume all risks and liabilities in connection therewith. Canusa’s liability is stated in the standard terms and conditions of sale. Canusa makes no other warranty either expressed or implied. All information contained in this installation guide is to be used as a guide and is subject to change without notice. This installation guide supersedes all previous installation guides on this product. E&OE Printed on recycled paper. Recyclable. PDS-CW-rev014 Our Submittal PAGE 12 / 12 Field Joint View Supplied Product View WLO/ KLO type heat-shrinkable sleeves Table 1: Summary of Dimensions Dimension Description A B C D E F G H I Pipe Diameter Total Cutback Length Factory Coating Sleeve Width Factory Coating Overlap Sleeve Length Closure Width (Pre-attached) Adhesive Thickness (“as supplied”) Backing Thickness (“as supplied”) 25 Bethridge Road, Toronto, Ontario, Canada M9W 1M7 Unit of Measure inch mm -mm mm mm mm mm mm Tel: (416) 743-7111 Nominal Value Various 300 3LPE 450 75 Various 100 1.65 0,9 Fax: (416) 743-5927 www.canusacps.com Product Data Sheet Wrapid Tape™ Primerless Crosslinked Protective Tape Canusa-CPS is a leading manufacturer of specialty pipeline coatings which, for over 30 years, have been used for sealing and corrosion protection of pipeline joints and other substrates. Canusa high performance products are manufactured to the highest quality standards and are available in a number of configurations to accommodate your specific project applications. Product Description Canusa Wrapid Tape™ consists of a crosslinked polyolefin backing, coated with a protective, heat sensitive anticorrosion adhesive which effectively bonds to steel substrates and common pipeline coatings including polyethylene and fusion bonded epoxy. Upon the application of heat, Wrapid Tape™ shrinks down to fully encapsulate the protected substrate. The product is packaged in convenient rolls with various widths to protect and repair pipelines, fittings, bends, elbows and other irregular configurations. Features & Benefits Easy Installation The flexibility provided by the thinner tape dimension allows Wrapid Tape™ to effectively protect both conventional substrates such as circular pipe as well as irregular transitions such as elbows and risers. Upon the application of heat, the specially formulated adhesive flows into all surface irregularities, forming a protective barrier against corrosion. Saves Time & Money Wrapid Tape™ is quick and easy to install. Since no special priming or operator equipment is required, product installation is quick and labour costs are kept to a minimum. Unlike conventional cold-applied tapes, Wrapid Tape™ does not require the use of high volatile primers, further minimizing costs and risks to health and safety. CANUSA-CPS is registered to ISO 9001:2008. Long Term Protection Wrapid Tape™ is manufactured using materials that provide high electrical resistivity, low water absorption and low moisture permeability. The unique crosslinking process results in a protective backing that is much tougher than conventional tapes, more effectively resisting abrasion and damage, and thus extending the lifetime of the substrate. Wrapid Tape™ can also be double or triple wrapped for extra mechanical protection when required. Applications Oil & Gas Water Pipelines Repair & Rehab Fittings Bends Girth-Weld Joints Configurations Wrapid Tape™ 2-Layer Pipe Sizes All Sizes Temperature Range up to 55°C (131°F) The product selection chart shown here is intended as a guide for standard products. Consult your Canusa representative for specific projects or unique applications. Wrapid Tape™ Operating Characteristics Tape Usage Guide Hot Melt Fahrenheit Pipeline 110o Operating Temperature HCO Nominal Pipe Diameter DN inches o 194 90 o 2.8 9.3 40 1.5 50 2 4.0 13.2 4.6 15 50 2 50 2 5.2 17 6.2 20.3 120 30o 85o -40°C Minimum Installation Temperature -40°F °C (°F) 60 (140) Resistance to Soil Stress 65 (149) 60 (140) good fair good Main Line Coating Compatibility Bit, CT, PU, PE, PP, FBE PE, FBE, PU Unit HCA HCO °C (°F) 72 (162) 102 (216) 90 (194) N/cm (psi) 2 60 (87) 40 (58) 30 (44) 0.93 0.93 0.93 MPa (psi) 20 (2900) 20 (2900) 20 (2900) ASTM D638 % 600 600 600 ASTM D2240 Shore D 46 46 46 Abrasion Resistance ASTM D1044 mg 45 45 45 Impact ASTM G14 Peel ASTM D1000 Water Absorption ASTM D570 Cathodic Disbondment ASTM G8 ASTM E28 Lap Shear ASTM D1002 Specific Gravity ASTM D792 Tensile Strength ASTM D638 Elongation Hardness Low Temp. Flexibility ASTM D2671C DIN Approval DIN 30 672 80 3 50 2 8.5 28 10.6 34.7 100 4 50 2 12.3 40 14.8 48.6 125 5 75 3 11.1 36.4 13.6 44.6 150 6 75 3 14.3 46.9 18.3 60 200 8 100 4 16.3 53.4 20.8 68.2 250 10 100 4 23.1 75.8 30.6 100.4 300 12 100 4 30.4 99.8 40.9 134.2 >300 >12 150 6 see formula below HCC pass/fail pass pass pass N/cm (pli) 35 (20) 52 (30) 26 (15) 0.05 % 0.05 0.05 mm rad 13 6 8 kV/mm 27 27 27 °C (°F) -32 (-25) 5 (23) -14 (-7) class C30/C50 – – mm (mils) 1.5 (60) 1.5 (60) 1.5 (60) The above table shows the typical usage for 3D and 5D bends, assuming a line coating cutback of 150 mm (6") and a 50 mm (2") overlap onto the pipe coating. 50mm Test Standard Softening Point Material Usage Table Adhesive Backing feet o 50 2.8 9.3 M 50 2 Dielectric Voltage Brkdwn. ASTM D149 Tape feet 1 Typical Product Properties L For other sizes, the following formula can be used: Length of tape = x pipe diameter x L/W where L=length of area to be covered, and W= ½ of tape width (for 50% overlap) 150mm 50mm Our Submittal: 100mmx10meter Roll How To Order: Dimensions & Ordering Info M 25 o Fully Recovered Thickness mm inches Length of Tape Required 3D Bend 5D Bend o 158 70 Recommended Tape Width HCC 230o o Tape Operating Characteristics HCA 150mm Celsius Mastic HCA-B 75-15 BK Wrapid Tape™ Colour BK-Black, YE-Yellow 10m (33.3 ft) 15m (50 ft) Length of Roll 50, 75, 100, 150, 200, 300 mm (2", 3", 4", 6", 8", 12") Width of Roll B - Bulk Roll Designation Bulk Roll Designation Adhesive (thickness as supplied) A - 0.75 mm (30 mils), O - 0.75 mm (30 mils) , C - 0.75 mm (30 mils) Backing (thickness as supplied) C - 0.4 mm (16 mils) Configuration H - Tape The above represents standard ordering options. Consult your Canusa representative for any unique project requirements. www.canusacps.com Canada U.S.A./Latin America Europe/Middle East Asia/Pacific CANUSA-CPS a division of SHAWCOR LTD. 25 Bethridge Road Rexdale, Ontario M9W 1M7, Canada Tel: +1 (416) 743-7111 Fax: +1 (416) 743-5927 CANUSA-CPS a division of SHAWCOR INC. 2408 Timberloch Place Building C-8 The Woodlands, Texas 77380, U.S.A. Tel: +1 (281) 367-8866 Fax: +1 (281) 367-4304 CANUSA-CPS a division of Canusa Systems Ltd. Unit 3, Sterling Park Gatwick Road Crawley, West Sussex England RH10 9QT Tel: +44 (1293) 541254 Fax: +44 (1293) 541777 CANUSA-CPS a division of SHAWCOR LTD. #05-31, Blk 52, Frontier Ubi Avenue 3 Singapore 408867 Tel: +65-6749-8918 Fax: +65-6749-8919 Canusa warrants that the product conforms to its chemical and physical description and is appropriate for the use stated on the installation guide when used in compliance with Canusa’s written instructions. Since many installation factors are beyond our control, the user shall determine the suitability of the products for the intended use and assume all risks and liabilities in connection therewith. Canusa’s liability is stated in the standard terms and conditions of sale. Canusa makes no other warranty either expressed or implied. All information contained in this installation guide is to be used as a guide and is subject to change without notice. This installation guide supersedes all previous installation guides on this product. E&OE Printed on recycled paper. Recyclable. PDS-A4-WT-rev015 Installation Guide CanusaWrap™ Two-piece protective bulk roll with separate closure Product Description 1 Storage & Safety Guidelines Equipment List 2 3 -CP USA CAN S Bulk Roll Closure CanusaWrapTM is typically shipped in bulk rolls. The adhesive is protected from contamination by an inner liner. Closures are shipped either in bulk rolls or pre-cut. These installation instructions are intended as a guide for standard products. Consult your Canusa representative for specific projects or unique applications. Product Preparation Guidelines Closure L Corner Cuts Cut Sleeve Overlap Underlap B W Sleeve width >450mm Pipe O.D. A-100mm, B-50mm Closure <450mm Pipe O.D. A-50mm, B-25mm A Pipe O.D.: <450mm (18") 100 mm overlap >450mm (18") 150 mm overlap 5 SOLVENT overlap Propane tank, hose, torch & regulator Appropriate tools for surface abrasion Knife, roller, rags & Canusa approved solvent cleanser Digital thermometer with suitable probe Standard safety equipment: gloves, goggles, hard hat, etc. Surface Preparation Bulk Roll 4 SOLVENT To ensure maximum performance, store Canusa products in a dry, ventilated area. Keep products sealed in original cartons and avoid exposure to direct sunlight, rain, snow, dust or other adverse environmental elements. Avoid prolonged storage at temperatures above 35°C (95°F) or below -20°C (-4°F). Product installation should be done in accordance with local health and safety regulations. As a guideline,cut the required lengths of Sleeve material (L)and Closure material (W) from the bulk roll as follows L = Coated Pipe circumference + overlap dimension W = Sleeve Width Ensure that the sleeve and closure are not damaged or contaminated. Trim corners as shown . Ensure that the PE coating edges are beveled to 30°. Clean exposed steel and adjacent pipe coating with a solvent cleanser to remove the presence of oil, grease, and other contaminants. Surface Preparation and Pre-Heat Chart Flame Intensity & Torch Size Please see “CanusaWrapTM Sleeve Cutting Guideline” for more information on alternative cutting methods. Hot Melt Mastic 6 Standard Sleeves WLG WLC WLS WLO WLON WLNN WLA WLAS WTG WTC WTS WTO WTON WTNN Surface Preparation SIS Standard SSPC Standard Minimum Preferred Minimum Preferred SP2 St2 SP6 Sa2 SP6 St2 SP2 Sa2 SP6 St2 Sa2 SP2 SP6 St2 Sa2 SP2 SP6 St2 Sa2 SP2 SP10 St3 Sa2½ SP3 SP10 St3 Sa2½ SP3 SP10 St3 Sa2½ SP3 Min. Pre-Heat Temp. °C (°F) 50 60 65 75 75 90 60 90 (122) (140) (150) (167) (167) (195) (140) (195) h idt 0mm e W e+5 v e Sle Sleev + m 0m Pipe O.D. <450mm (18") Pipe O.D. >450mm (18") Use moderate flame intensity for pre-heating and shrinking. Use moderate to high flame intensity for preheating and shrinking. Minimum Torch Size: 150,000 BTU/hr. Minimum Torch Size: 300,000 BTU/hr. Pre-Heat Surface Preparation 8 7 9 10 5 Ensure that the pipe is dry before cleaning. Prepare the steel joint area using the Surface Preparation and Pre-Heat as a guideline. Lightly abrade the pipe coating adjacent to the cutback area to a distance of 50mm (2") beyond each end of the sleeve width. Wipe clean or air blast the steel and pipe coating to remove foreign contaminants. CANUSA-CPS is registered to ISO 9001:2008. Pre-heat the joint area to the minimum required temperature (see Surface Preparation & Pre-Heat Chart). Using a temperature measuring device, ensure that the correct temperature is reached on the steel and at least 50mm (2") on each side of the sleeve. Part No. 99060-022 CanusaWrap™ Sleeve Installation 11 12 10 13 2 1 2 Partially remove the release liner and gently heat the underlap approximately 150 mm (6") from the edge. Centre the sleeve over the joint so that the sleeve overlaps between the 10 and 2 o'clock positions. Press the underlap firmly into place and remove the remaining release liner. Wrap the sleeve loosely around the pipe, ensuring the appropriate overlap. Gently heat the backing of the underlap and the adhesive side of the overlap. Press the overlap into place. 14 15A C E B D F Remove any release liners from the closure. Centre the closure on the overlapping sleeve. Press down firmly. Gently heat the closure and pat it down with a gloved hand. Repeating this procedure, move from one side to the other. Smooth any wrinkles by gently working them outward from the centre of the closure with a roller. 16 17 18 Using the appropriate sized torch, begin at the centre of the sleeve and heat circumferentially around the pipe. Use broad strokes. If utilizing two torches, operators should work on opposite sides of pipe. Continue heating from the centre toward one end of the sleeve until recovery is complete. In a similar manner, heat and shrink the remaining side. Shrinking has been completed when the adhesive begins to ooze at the sleeve edges all around the circumference. Finish shrinking the sleeve with long horizontal strokes over the entire surface to ensure a uniform bond. 19 20 21 Continue the procedure by also firmly rolling the closure with long horizontal strokes from the weld outwards. Visually inspect the installed sleeve for the following: • Sleeve is in full contact with the steel joint. • Adhesive flows beyond both sleeve edges. • No cracks or holes in sleeve backing. Pipe O.D.: <450mm (18") 1 torch >450mm (18") 2 torches Inspection 2 1 2 1 While the sleeve is still hot and soft, use a hand roller to gently roll the sleeve surface and push any trapped air up and out of the sleeve, as shown above. If necessary, reheat to roll out air. Backfilling Guidelines After shrinking is complete, allow the sleeve to cool for 2 hours prior to lowering and backfilling. To prevent damage to the sleeve, use selected backfill material, (no sharp stones or large particles) otherwise an extruded polyethylene mesh or other suitable shield should be used. www.canusacps.com Canada U.S.A./Latin America Europe/Middle East Asia/Pacific CANUSA-CPS a division of SHAWCOR LTD. 25 Bethridge Road Rexdale, Ontario M9W 1M7, Canada Tel: +1 (416) 743-7111 Fax: +1 (416) 743-5927 CANUSA-CPS a division of SHAWCOR INC. 2408 Timberloch Place Building C-8 The Woodlands, Texas 77380, U.S.A. Tel: +1 (281) 367-8866 Fax: +1 (281) 367-4304 CANUSA-CPS a division of Canusa Systems Ltd. Unit 3, Sterling Park Gatwick Road Crawley, West Sussex England RH10 9QT Tel: +44 (1293) 541254 Fax: +44 (1293) 541777 CANUSA-CPS a division of SHAWCOR LTD. #05-31, Blk 52, Frontier Ubi Avenue 3 Singapore 408867 Tel: +65-6749-8918 Fax: +65-6749-8919 Canusa warrants that the product conforms to its chemical and physical description and is appropriate for the use stated on the installation guide when used in compliance with Canusa’s written instructions. Since many installation factors are beyond our control, the user shall determine the suitability of the products for the intended use and assume all risks and liabilities in connection therewith. Canusa’s liability is stated in the standard terms and conditions of sale. Canusa makes no other warranty either expressed or implied. All information contained in this installation guide is to be used as a guide and is subject to change without notice. This installation guide supersedes all previous installation guides on this product. E&OE Printed on recycled paper. Recyclable. IG-A4-CW-rev013 Installation Guide Wrapid Tape™ HCA, HCO, HCC Primer-less, Crosslinked, Corrosion Protection Tape. Product Description Storage & Safety Guidelines 1 Equipment List 3 2 Canusa Wrapid Tape™ is supplied in 15 m length bulk rolls, in several widths to suit the project diameter. These installation instructions are intended as a guide for standard products. Consult your Canusa representative for specific projects or unique applications. Flame Intensity & Torch Size Surface Preparation Pipe O.D. <450mm (18") Pipe O.D. >450mm (18") Use moderate flame intensity for pre-heating and shrinking. Use moderate to high flame intensity for preheating and shrinking. Minimum Torch Size: 150,000 BTU/hr. Minimum Torch Size: 300,000 BTU/hr. 7 5 SOLVENT 4 SOLVENT To ensure maximum performance, store Canusa products in a dry, ventilated area. Keep products sealed in original cartons and avoid exposure to direct sunlight, rain, snow, dust or other adverse environmental elements. Avoid prolonged storage at temperatures above 35°C (95°F) or below -20°C (-4°F). Product installation should be done in accordance with local health and safety regulations. Propane tank, hose, torch & regulator Appropriate tools for surface abrasion Knife, roller, rags & approved solvent cleanser Digital thermometer with suitable probe Standard safety equipment; gloves, goggles, hard hat, etc. 6 50m Taped Area m m+Tape+50m Ensure that the PE coating edges are beveled to 30°. Clean exposed steel and adjacent pipe coating with a solvent cleanser to remove the presence of oil, grease, and other contaminants. Ensure that the pipe is dry before cleaning. Prepare the steel joint area to a minimum of St3 /SP3. Lightly abrade the pipe coating adjacent to the weld area to a distance of 50mm (2") beyond each end of the area to be taped. Pre-Heat Tape Installation 8 9 50mm HCC 60°C (140°F) HCA 60°C (140°F) HCO 75°C (165°F) Wipe clean or air blast the steel and pipe coating to remove foreign contaminants. Pre-Heat the joint area to the minimum required temperature HCA: 60°C (140°F) HCO: 75°C (165°F) HCC: 60°C (140°F). Using a temperature measuring device, ensure that the correct temperature is reached on the steel and at least 50mm (2") on each side of the tape. CANUSA-CPS is registered to ISO 9001:2008. Starting at least 50mm (2") onto the pipe coating, begin wrapping the tape around the joint, ensuring a minimum 50% spiral overlap. Ensure that the powdered tape side is placed onto the pipe. Remove any plastic release liners as the product is wrapped. Part No. 99060-016 Wrapid Tape™- HCA, HCO, HCC 10 11 12 Continue wrapping the pipe ensuring a minimum 50% overlap. Warm the tape end and press down firmly. A holddown tape can be used to secure the tape end. Using a torch, begin at the edge of the tape and heat circumferentially around the joint, working back to the other edge. Inspection Backfilling Guidelines 13 14 After shrinking is complete, allow the sleeve to cool for 2 hours prior to lowering and backfilling. To prevent damage to the sleeve, use selected backfill material, (no sharp stones or large particles). Otherwise, an extruded polyethylene mesh or other suitable shield should be used. Visually inspect the taped joint for the following: • Tape is in full contact with the joint and extends 50mm (2") onto the pipe coating. • Adhesive flows at the tape edges. • No cracks or holes in the tape. Material Usage Table Tape Usage Guide DN inches mm inches Length of Tape Required 3D Bend 5D Bend m feet m feet 25 1 50 2 2.8 9.3 2.8 9.3 40 1.5 50 2 4.0 13.2 4.6 15 50 2 50 2 5.2 17 6.2 20.3 80 3 50 2 8.5 28 10.6 34.7 100 4 50 2 12.3 40 14.8 48.6 125 5 75 3 11.1 36.4 13.6 44.6 150 6 75 3 14.3 46.9 18.3 60 200 8 100 4 16.3 53.4 20.8 68.2 250 10 100 4 23.1 75.8 30.6 100.4 300 12 100 4 30.4 99.8 40.9 134.2 >300 >12 150 6 The table at left shows the typical usage for 3D and 5D bends, assuming a line coating cutback of 150 mm (6") and a 50 mm (2") overlap onto the pipe coating. 150mm Recommended Tape Width 50mm Nominal Pipe Diameter L For other sizes, the following formula can be used: Length of tape = x pipe diameter x L/W where L=length of area to be covered, and W= ½ of tape width (for 50% overlap) 150mm 50mm see formula at right www.canusacps.com Canada U.S.A./Latin America Europe/Middle East Asia/Pacific CANUSA-CPS a division of SHAWCOR LTD. 25 Bethridge Road Rexdale, Ontario M9W 1M7, Canada Tel: +1 (416) 743-7111 Fax: +1 (416) 743-5927 CANUSA-CPS a division of SHAWCOR INC. 2408 Timberloch Place Building C-8 The Woodlands, Texas 77380, U.S.A. Tel: +1 (281) 367-8866 Fax: +1 (281) 367-4304 CANUSA-CPS a division of Canusa Systems Ltd. Unit 3, Sterling Park Gatwick Road Crawley, West Sussex England RH10 9QT Tel: +44 (1293) 541254 Fax: +44 (1293) 541777 CANUSA-CPS a division of SHAWCOR LTD. #05-31, Blk 52, Frontier Ubi Avenue 3 Singapore 408867 Tel: +65-6749-8918 Fax: +65-6749-8919 Canusa warrants that the product conforms to its chemical and physical description and is appropriate for the use stated on the installation guide when used in compliance with Canusa’s written instructions. Since many installation factors are beyond our control, the user shall determine the suitability of the products for the intended use and assume all risks and liabilities in connection therewith. Canusa’s liability is stated in the standard terms and conditions of sale. Canusa makes no other warranty either expressed or implied. All information contained in this installation guide is to be used as a guide and is subject to change without notice. This installation guide supersedes all previous installation guides on this product. E&OE Printed on recycled paper. Recyclable. IG-A4-WT-rev012 Product Data Sheet Pipeline Repair Products Mainline coating repair products for corrosion protection Canusa-CPS is a leading manufacturer of specialty pipeline coatings which, for Repair Patch Mastic Filler over 30 years, have been used for S SA-CP CANU S SA-CP CANU sealing and corrosion protection of pipeline joints and other substrates. Canusa high performance products are manufactured to the highest quality standards and are available in a number of configurations to accommodate your specific project applications. Melt Stick Product Description Canusa’s Pipeline Repair Products are used to add corrosion protection and/or fill voids in damaged coatings. A full line of products provides the flexibility to make a variety of repairs to mainline coatings, ranging from minor coating damage to holidays and exposed steel. Features & Benefits All of Canusa's Pipeline Repair Products offer flexibility of installation, exhibit excellent adhesion to steel and are compatible with common pipeline coatings. These products also remain permanently flexible and provide superior resistance to moisture infiltration, resulting in a sound corrosion protection layer. The Coating Repair Patch (CRP) CRP consists of an irradiated, crosslinked polyolefin sheet coated with a heat-activated adhesive. It is designed specifically for sealing and protection of damaged pipeline coatings up to 150mm x 150mm in size. The patch can be installed quickly with no special tools required. The installed patch provides a barrier to moisture and corrosion and is resistant to abrasion and shear forces during pipeline installation and while in-service. CANUSA-CPS is registered to ISO 9001:2000. Applications Melt Sticks (MS) Melt Sticks are heat-activated adhesives supplied as a rod for ease of application. They are ideal for small coating repairs ranging from superficial damage to holidays and cracks up to 10mm x 10mm. Melt sticks may also be used as a filler material below Coating Repair Patches. Mastic Filler (MF) Mastic Filler is used to fill larger voids and deep crevices in damaged coatings prior to the application of Canusa Repair Patches. Note: For damage greater than 150mm x 150mm, a new sleeve is recommended. Oil & Gas Water Pipelines Repair & Rehab Configurations -CPS CANUSA Patch Melt Stick Mastic Filler Epoxy Pipe Sizes All Sizes Temperature Range up to 65°C (150°F) Pipeline Repair Products The product selection chart shown here is intended as a guide for standard products. Consult your Canusa representative for specific projects or unique applications. Pipeline Operating Characteristics Product Selection Guide Celsius Fahrenheit 110° 230° 90° 194° 70° 158° 50° 122° 30° 86° Pipeline Operating Temp. Minimum Installation Temp. °C (°F) °C (°F) Resistance to Circumferential Forces Resistance to Soil Stress Resistance to Axial Pipe Movement CRP0 CRPN CRP65 50 (122) 75 (167) 60 (140) 80 (176) 65 (150) 90 (195) good good good good good good excellent excellent excellent Patch Backing Adhesive Product Properties Test Standard Unit CRPN CRP65 °C (°F) 102 (216) 124 (255) 94 (201) N/cm (psi) 2 40 (58) 52 (75) 245 (350) 0.93 0.93 0.93 MPa (psi) 24 (3480) 24 (3480) 24 (3480) ASTM D638 % 700 700 700 ASTM D2240 Shore D 48 48 48 Abrasion resistance ASTM D1044 mg 35 35 Volume Resistivity ASTM D257 ohm-cm 10 10 10 Dielectric Voltage Brkdwn ASTM D149 kV/mm 27 27 27 Impact DIN 30 672 class C pass pass pass Indentation DIN 30 672 class C pass pass Peel to PE or Steel ASTM D1000 N/cm (pli) 80 (46) 115 (66) 120 (70) Peel to PE or Steel DIN 30 672 class C50 N/cm (pli) 65 (37) 90 (51) 86 (50) Cathodic Disbondment ASTM G8 mm rad 8 17 13 Water Absorption ASTM D570 % 0.05 0.05 0.05 Low Temp. Flexibility ASTM D2671-C °C (°F) -14 (7) -15 (5) -26 (-18) Softening point ASTM E28 Lap shear DIN 30 672 Specific gravity ASTM D792 Tensile strength ASTM D638 Elongation Hardness CRPO 17 17 35 17 pass How To Order: CRPN - B 150-30 BK Colour Canusa Repair Patch Mastic Filler 3.0 m (10’) 7.5 m (25’) 15 m (50’) 300 mm (12”) Length Diameter 10 mm (3/8”) Thickness 3 mm (1/8”) Width 50 mm (2”) N - 0.63 mm (25 mils) Adhesive 1- (hot melt) 65 - 0.63 mm (25 mils) O - 1.1 mm (45 mils) Product Designation Width of Roll 150 (6”) - 450 (18") Configuration B-Bulk Roll Product Designation MF-B 50-3-7.5 Length 15m, 30m (50 ft, 100 ft) Backing (thickness as supplied) Melt Stick BK-Black Length of Roll Adhesive (thickness as supplied) MS-1 10-300 Configuration MS - Melt Stick Product Designation B - Bulk Roll MF - Mastic Filler 0.80 mm (32 mils) CRP-Coating Repair Patch www.canusacps.com Canada U.S.A./Latin America Europe/Middle East Asia/Pacific CANUSA-CPS a division of SHAWCOR LTD. 25 Bethridge Road Rexdale, Ontario M9W 1M7, Canada Tel: +1 (416) 743-7111 Fax: +1 (416) 743-5927 CANUSA-CPS a division of SHAWCOR INC. 2408 Timberloch Place Building C-8 The Woodlands, Texas 77380, U.S.A. Tel: +1 (281) 367-8866 Fax: +1 (281) 367-4304 CANUSA-CPS a division of Canusa Systems Ltd. Unit 3, Sterling Park Gatwick Road Crawley, West Sussex England RH10 9QT Tel: +44 (1293) 541254 Fax: +44 (1293) 541777 CANUSA-CPS BrederoShaw (S) Pte Ltd 101 Thomson Road #17-01/02, United Square Singapore 307591 Tel +65-6732-2355 Fax +65-6732-9073 Canusa warrants that the product conforms to its chemical and physical description and is appropriate for the use stated on the installation guide when used in compliance with Canusa’s written instructions. Since many installation factors are beyond our control, the user shall determine the suitability of the products for the intended use and assume all risks and liabilities in connection therewith. Canusa’s liability is stated in the standard terms and conditions of sale. Canusa makes no other warranty either expressed or implied. All information contained in this installation guide is to be used as a guide and is subject to change without notice. This installation guide supersedes all previous installation guides on this product. E&OE Printed on recycled paper. Recyclable. PDS-A4-PRP-rev013 ADDITIONAL MATERIALS & ITEMS TO BE PROVIDED BY THE CONTRACTOR 1. Dry storage facilities for all materials supplied by Canusa-CPS following manufacturers guidelines. 2. All equipment and items related to surface preparation (including consumables). 3. Propane fuel supply requirements. 4. Sleeve installation equipment (propane torches, digital thermometers, rollers, etc.). 5. Disposal of empty cartons and associated waste. 6. Security and assistance with visas/work permits for specified Canusa-CPS personnel supplied for Training Services. All related costs associated with the visit of Canusa technician to be covered by contractor. 7. Holiday detection voltage equipment. 8. Standard safety equipment, including safety gloves, glasses, boots and hard hats Canada CANUSA-CPS a division of SHAWCOR LTD. 25 Bethridge Road Toronto, Ontario M9W 1M7, Canada Tel: +1 (416) 743-7111 Fax: +1 (416) 743-5927 U.S.A./Latin America CANUSA-CPS a division of SHAWCOR INC. 2408 Timberloch Place Building C-8 The Woodlands, Texas 77380, U.S.A. Tel: +1 (281) 367-8866 Fax: +1 (281) 367-4304 Europe/Middle East CANUSA-CPS a division of Canusa Systems Ltd. Unit 3, Sterling Park Gatwick Road Crawley, West Sussex England RH10 9QT Tel: +44 (1293) 541254 Fax: +44 (1293) 541777 Asia/Pacific CANUSA-CPS Bredero Shaw (S) Pte Ltd# 05-31, Blk 52, Frontier Ubi Avenue 3 Singapore 408867 Tel: +65-6749-8918 Fax: +65-6749-8919 www.canusacps.com