Activent® Antimicrobial Ventilation Tubes
Transcription
Activent® Antimicrobial Ventilation Tubes
Activent® Antimicrobial Ventilation Tubes INNOVATIVE OTOLOGIC SOLUTIONS An innovative advance in tympanostomy tubes Activent® antimicrobial ventilation tubes represent an innovative advance in tympanostomy tube technology. For the first time, ventilation tubes are available that inhibit growth of bacteria that can contribute to secondary infections and postoperative otorrhea.1 Made of silver oxide-impregnated silicone or fluoroplastic, Activent® antimicrobial ventilation tubes have a proven bacteriocidal/bacteriostatic effect. In vitro tests show a clear zone of bacterial inhibition around Activent antimicrobial ventilation tubes on plates inoculated with both a wide spectrum of bacteria and ones common in middle ear infections. No zone is present with conventional tubes.1 Activent antimicrobial tubes: an innovative advance in tympanostomy tube science with documented patient benefit.1 Activent antimicrobial ventilation tubes are available in silicone or fluoroplastic, in a variety of short- and long-term styles to meet patient needs. Incidence of Post-op Otorrhea1 (by percentage) 12 10 8 10.6% 6 4 2 0 Gray=Control Blue=Activent® 5.1% Overall Incidencea 3.8% Excluding First Post-op Weekb Overall incidence of otorrhea observed on post-operative visits was 9.8% in ears with control tubes versus 5.1% incidence in ears with Activent® antimicrobial ventilation tubes (P=0.010). a Excluding the first post-operative week, the incidence of otorrhea observed on post-operative visits was 10.6% in ears with control tubes versus 3.8% in ears with Activent antimicrobial ventilation tubes (P=0.002). b In vitro tests show a clear zone of bacterial inhibition around the Activent® antimicrobial ventilation tube.2 9.8% Demonstrated effective in reducing postoperative otorrhea 1,3 Clinical data show a significant reduction in the incidence of postoperative otorrhea in ears implanted with Activent antimicrobial ventilation tubes compared with conventional tubes. In a double-blind multicenter trial, the incidence of postoperative otorrhea was almost halved for ears implanted with Activent antimicrobial ventilation tubes, as compared with ordinary tubes.1 Excluding the first postoperative week, the difference is even more striking — there was almost three times the incidence of postoperative otorrhea with conventional tubes as compared with Activent antimicrobial ventilation tubes. Antimicrobial zones of inhibition: Activent® from Medtronic ENT (Black®) vs. UltraSil™ from Gyrus ACMI® (blue) on TSA plates Confluent inoculations of pseudomonas aeruginola ATCC 27853 Confluent inoculations of staphylococcus aureaus ATCC 25923 and bacillus subtlis Chole RA, MD, PhD, Hubbell, RN, MD. Antimicrobial Activity of Silastic Tympanostomy Tubes Impregnated with Silver Oxide: A Double-blind Randomized Multicenter Trial. Archives of Otolarnygology -Head and Neck Surgery.1995; 121: 562-565. 1 Independent laboratory results on file with Medtronic ENT. 2 Gourin, CG, MD, Hubbell, RN, MD. Otorrhea After Insertion of Silver Oxide-impregnated Silastic Tympanostomy Tubes. Archives of Otolarnygology -Head and Neck Surgery.1999; 125: 446-450. 3 silicone Activent® fluoroplastic Activent® Armstrong Beveled Grommets Product 1026055 1046055 ID 1.14 mm 1.14 mm Armstrong Beveled Grommets IFD 3.5 mm 3.5 mm Qty 5 5 pairs Armstrong Beveled Straight Shank Product 1026140 ID 1.14 mm IFD 3.6 mm L 7 mm Qty 5 Baxter Beveled Buttons Product 26631 ID 1.27 mm IFD 2.6 mm L 2.1 mm Qty 5 Donaldson-Type Tubes Product 1026020 1046020 ID 1.14 mm 1.14 mm IFD 2.3 mm 2.3 mm IFDis 0.9 mm 0.9 mm Qty 5 5 pairs FL 8.5 mm IFDis 2.5 mm Qty 5 IFD 9.5 mm IFDis 12 mm Qty 5 IFDis 4.5 mm Qty 5 Goode T-Grommets Product 1026011 ID 1.27 mm Goode T-Tubes® Product 1026010 ID 1.4 mm Goode T-Tubes, Modified Product 1026040 ID 1.27 mm IFD 9.5 mm Paparella-Type Vent Tubes, with Notch and Tab Product 1026001 1046001 1026045 ID 1.14 mm 1.14 mm 1.52 mm IFD 2.4 mm 2.4 mm 4.45 mm IFDis 1.1 mm 1.1 mm 1.15 mm Qty 5 5 pairs 5 IFDis 1.3 mm 1.3 mm 1.3 mm Qty 5 50 5 pairs Sheehy-Type Collar Buttons Product 1026145 1026146 1046145 ID 1.27 mm 1.27mm 1.27 mm IFD 2.9 mm 2.9 mm 2.9 mm Shepard Grommets, with Tail Product 1026025 1046025 ID 1.14 mm 1.14 mm Product 1026014 ID 1.27 mm IFD 2.3 mm 2.3 mm Qty 5 50 Qty 5 ID 1.14 mm Product 1026030 ID 1.02 mm IFD 5 mm IFD 3.5 mm Qty 5 Armstrong Beveled Grommets, Modified Product 1030170 ID 1.14 mm IFD 3.5 mm Qty 5 L 4.5 mm Qty 5 Armstrong V Tubes Product 1036121 ID 1.14 mm Baxter Beveled Buttons Product 34611 ID 1.27 mm IFD 3 mm L 2.1 mm Qty 5 IFD 2.3 mm IFDis 0.9 mm Qty 5 Donaldson-Type Tubes Product 1033000 ID 1.14 mm Moretz Tab Vent Tubes Product 1036177 ID 1.27 mm IFDis 1 mm Qty 5 Pediatric Ventilation Tubes Product 1036159 ID 0.76 mm IFD 2 mm Qty 5 IFD 2.1 mm 2.75 mm L 7 mm 7 mm Qty 5 5 IFD 3.6 mm IFDis 1.3 mm Qty 5 IFD 2.6 mm 2.9 mm 2.9 mm IFDis Qty 1.0 mm (without holes)5 1.0 mm (with holes) 5 1.0 mm (without holes)5 Plain Straight Shanks Product 1036165 1038050 ID 0.89 mm 1.14 mm Pope Beveled Grommets Product 1035004 ID 1.14 mm Reuter Bobbins Product 1036162 1037000 1037005 ID 1.02 mm 1.14 mm 1.14 mm Shah-Type Ventilation Tubes Product 1038030 ID 1.14 mm IFDis 1.58 mm Qty 5 Product 1038040 ID 1.27 mm IFD 3 mm IFDis 1.55 mm Qty 5 Shepard Grommets, with Wire Touma T-Type Grommets Product 1026012 ID 1.14 mm Shah-Type Collar Buttons Touma Beveled T-Grommet, with Tab IFD 5 mm Product 1030030 Qty 5 Product 1038012 ID 1.14 mm IFD 2.4 mm Qty 5 Umbrella Ventilation Tubes, with Tab Qty 5 All dimensions are approximate. ID = Inner Diameter OFD = Outer Flange Diameter IFD = Inner Flange Diameter IFDis = Interflange Distance L = Length FL = Flange Length For further information, please call Medtronic ENT at 800-874-5797 or 904-296-9600. You may also consult our website at www.MedtronicENT.com. Medtronic ENT Medtronic USA, Inc. 6743 Southpoint Drive North Jacksonville, FL 32216 USA www.MedtronicENT.com Toll free: (800) 874-5797 Fax: (800) 678-3995 International Telephone Numbers Adriatic Regional Office 385-1-488-1120 Australia 1800-668-670 Baltic Regional Office 37-1-67560226 Belgium 32-2456-09-09 Canada 1800-217-1617 China 86-21-50800998 Czech Republic 420-2-9657-9580 France 33-470-679-800 Germany 49-2159-8149-209 Greece 30-210-67-79-099 Hong Kong 852-2919-1312 Hungary 36-30-5052987 India 91-22-26836733 Israel 972-9-972-4400 Italy 39-02-24137-324 Japan 81-6-4795-1506 Korea 82-2-3404-3600 Lebanon 961-1-370-670 Luxembourg 32-2456-09-09 Netherlands 31-45-566-8800 Poland 48-22-465-6942 Russian Federation 7-495-580-73 77 Singapore 65-6776-6255 South Africa 27-11-466-1820 Spain 34-91-625-05-40 UK 44-1923-205-166 USA 1-904-296-9600 This literature is intended for the exclusive use of physicians. Rx only. Activent®, Black®, and Goode T-Tubes® are registered trademarks of Medtronic, Inc. UltraSil™ is a trademark of Gyrus ACMI®. © 2009, Medtronic, Inc. 890160 09.09 2010-103 Rev 2 L 2.2 mm