Environmentally Friendly Inverter Oil Cooling Unit
Transcription
Environmentally Friendly Inverter Oil Cooling Unit
AKZ RoHS Compliant 9 SERIES Use of new refrigerant R410A I N D E X AKZ 9 series Features P1∼2 Principle/ Piping system diagram P3 Description of model symbols P4 Specifications and range of use P5∼6 Cooling capacity characteristic chart P7∼8 Outside dimension diagram P9∼18 Optional parts Thermistor P19 Expansion board for main machine communication P20 Supporting information Control panel/Operation mode/Setting method P21∼22 Electric schematic diagram P23 Electric wiring connection instruction diagram P24 Notes for handling P25∼27 Method of selection P28 High-accuracy, Energy-saving, Compact Table of history P29 Environmentally Friendly Inverter Oil Cooling Unit Service network P30 9 AKZ SERIES Oil Hydraulic Division Oil Hydraulic Equipment 9 AKZ SERIES Circulation type AKZ 9 SERIES RoHS Compliant Features Features Further Evolution of High-accuracy Temperature Control Achieve high energy-saving performance ■Our acclaimed ±0.1℃ oil temperature control has been extended to cover an even wider range. ■Achieve high energy-saving performance with the adoption of a Daikin original IPM motor and R410A refrigerant for high COP characteristics. ■The cooling capacity resolution in the low-load range has been improved through optimal control of the compressor and electronic expansion valve. ■The power consumption can be checked on Reduction of the operation panel. approximately Reduction of approximately *2 45% *2 20% Expansion of cooling capacity control range 100 Main machine heating generation Power consumption (*1) ■Control with loads from 0% (no load) to 100% achieved High load Low-load No load Time 80 60 40 20 0 ■AKZ 9 series Non-inverter unit(Daikin) Outlet oil temperature control AKZ 8 series AKZ 9 series *1. Comparison taking a non-inverter unit to have a power consumption of 100 *2. Measured during Daikin’ s model operation patterns Target temperature ±0.1℃ Achieve low-noise operation in the low-load range Note)Pattern diagram with the heating load stabilized at 0 - 100% (Comparison with Daikin unit) AKZ 8 AKZ 9 59.5dB(A) RoHS Compliant * 58dB(A) Corresponding value in anechoic chamber (with AKZ 439 class) ■Complies with the RoHS Directive, e.g. by adopting printed circuit boards with lead-free solder. ■Noise level also reduced in line with load reduction *At room temperature of 25 and thermal load of 1 kW Compact design of top class in the industry *Compared with AKZ 439 class(Unit: mm) 7series 9series 8series The AKZ 9 series 875 More compact 990 1,020 comes top in the industry 440 440 360 1 360 360 440 Features Functions featured ■The ingress protection of the control box has been upgraded (equivalent to IP54). ■Refrigerant gas leakage detection alarm function An alarm signal is output when the refrigerant gas would be leaked (as cooling circuit failure). ■Oil temperature warning function A warning signal can be output when the oil temperature or air temperature strays outside arbitrarily setting range. ■Electronic components resistant to sulfidization have been adopted. Higher durability for long-distance transportation ■Auto tuning function This function substantially cuts the time taken for adjustment during trial operation by automatically setting the gain when oil temperature control is not stable in the factory setting status or when optimization is required. ■The specifications for withstanding vibration during transport have been upgraded to reflect actual transportation conditions. Five types of semi-standard specification units in addition to the standard type to achieve shorter product delivery terms With heater With tank With breaker ■999-hour timer function (ON timer) The operation start time can be set from 0 to 999 hours in one-hour units. Different voltages Compliance with CE New functions for ease of use ■Preventive maintenance function ●A warning signal is output to notify that maintenance is required when the air filter or condenser becomes clogged. ●If the thermistor fails (out of control), emergency operation is possible by selecting another operation mode. This function minimizes the factors of line stoppages. Easy monitoring of operating status ■The room temperature, inlet and outlet oil temperatures and other internal data can be monitored at a personal computer using Hybrid-Win*. This data can be displayed collectively, making it easy to grasp the operating status. Improved operability/maintainability ■The control panel has been revamped. Data is now displayed in an easier-to-understand format with more digits space. The power consumption is also displayed (new function). ■The newly adopted plug-in terminal block has enabled tool-less connection of signal cables (simple connection). *Hybrid-Win is a software tool for monitoring the internal status of the unit using a personal computer. You can download the tool and its instruction manual free of charge from the website (http://www.daikinpmc.com) after registering as a user. *The communications cable and the monitor harness must be purchased separately. RS232C communications cable Features Individual specifications for general purpose are set as semi-standard types AKZ 9 SERIES Reinforce durability for mist or dust in the severe condition of factory Monitor harness for oil cooling units ■The increased pitch of the condenser’ s fins suppresses clogging and makes cleaning easier. (1.5 mm previously → 1.8 mm) Applications ■Example of major applications Built-in motor Machine tools:Machining center, NC lathe, grinding machine, NC specialized machine, NC electric discharge machine, etc. Industrial machine:Molding machine, press, etc. Cooling of cooling oil Cooling of periphery of built-in motor ● Minimize the thermal displacement of spindle ● Minimize the thermal displacement of column ● Prevent temperature rise of motor coil Spindle Cooling of hydraulic oil Gearbox Column Cooling of lubricant Cooling in gear box Temperature(viscosity)control ● Minimize the thermal displacement of spindle ● Minimize the thermal displacement of column ● Prevention of deterioration of hydraulic oil(Longer life) ● Stabilized operation of actuator Tool M Hydraulic unit Workpiece Bed Example of use at machining center 2 9 AKZ SERIES Principle and overall system diagram Control board Inlet oil temperature thermistor(To *1) Outlet oil temperature thermistor(To *2) Oil temperature control thermistor(To *3) 〈Optional part〉 Room temperature thermistor(To *4) Machine temperature synchronous thermistor(To *5) 〈Optional part〉 Pressure reducing mechanism B E Principle and overall system diagram/series piping system diagram Bypass mechanism M Oil outlet (Oil) ︵ Cooler ︶ Evaporator *4 D Fan Condenser (Suction air) AKZ 9 SERIES C *5 *2 Machine tools *1 Oil inlet *3 M (Refrigerant) A Oil pump (Compressor) Tank Note)1. Refer to Pages 19 and 20 for optional parts. 2. Refer to Pages 21 and 22 for detailed setting and others. 【Refrigerating cycle】 A:Refrigerant gas is converted into compressed gas at high temperature and high pressure by a compressor so that gas can be easily cooled and liquefied by a condenser. B:In the condenser, the gas at high temperature and high pressure made in the compressor is cooled with air and converted into liquid at high temperature and high pressure. C:The pressure reduction mechanism reduces the pressure of the liquid at high temperature and high pressure and converts it into liquid at low temperature and low pressure by squeezing it so that it can be easily evaporated in a cooler. D:In the cooler, liquid at low temperature and low pressure made in the pressure reduction mechanism removes heat from oil, evaporates(cools oil), and is converted into gas at low temperature and low pressure. E:The bypass mechanism controls the cooling capacity at low loads by adjusting the volume of gas at high temperature and high pressure supplied to the cooler. 9 AKZ SERIES Series piping system diagram Electronic expansion valve Control board *1 *2 *3 *4 *5 Filter Evaporator Room temperature thermistor *4 Electronic expansion valve Outlet temperature thermistor *5 Outlet oil temperature thermistor Oil outlet Plugged High-pressure S3 switch PH (-C type only) Oil drain Condenser Low pressure gauge port *3 Condensation temperature thermistor Compressor protection thermostat (-C type only) Fan Hot gas bypass valve M Filter *2 Discharge gas temperature thermistor Oil pump M Relief valve Spindle of main machine S2T MC compressor *1 Inlet oil temperature thermistor Oil inlet Accumulator Tank of main machine 3 9 AKZ SERIES Description of model symbols ※※ 9 - ※※※ 1 2 3 4 5 Oil cooling unit identification code 4 2 5 Symbol of series (Symbol to represent model change) 6,7,8,9 …… Symbol for semi-standard types (B,C,H,T) B :With breaker C:Compliance with CE H:With heater T :With tank 046:Different voltage AC220,230V 50/60Hz 047:Different voltage AC380,400,415V 50/60Hz 048:Different voltage AC440,460,480V 50/60Hz Or, a serial number (three numerical digits) Non-standard specifications to meet individual requirements that are not covered by the semi-standard specifications * Contact us separately about special specifications (UL compliance, tropical treatment, etc.). Specifications of standard, semi-standard, and non-standard types Description of model symbols 3 :Used for units with a semi-standard specification or a combination of semi-standard specifications 5 below is a serial number, Single letter :When ■ the semi-standard specification is identified here with a single letter of the alphabet. Cooling capacity (kW) × 10 Indicates ten times the cooling capacity Examples: 14, 32, 43, 56, 90, where 14 indicates a cooling capacity of 1.4 kW Specification identification code - AKZ : High-accuracy inverter oil cooling unit [Circulation type, for spindle and lubricant] AKZ 9 SERIES 1 AKZ ■AKZ 9(Circulation type) Standard type Semi-standard Non-standard ○ ○ ○ ○ B C 046 047 048 H With heater T With tank ○ Discharge pressure (oil) : 0.98 MPa ○ Discharge pressure (oil) : 1.47 MPa ○ Use of twin pump ○ Specified painting color ○ With expansion board for serial communication Use of low-viscosity oil Discharge pressure (oil) : 0.5 MPa With timer With outlet temperature sensor With breaker Compliance with CE Without transformer Different voltages With transformer Remarks Viscosity of oil for use:1.4 ー 200 mm2/S 999-hour timer European Safety Standard AC220,230V 50/60Hz AC380,400,415V 50/60Hz AC440,460,480V 50/60Hz Unit with separately installed pump Unit with separately installed pump Unit with separately installed pump ■Optional parts(Refer to Pages 19 and 20) ・Machine temperature synchronous thermistor(Lead wire length: 5m, 10m, 15m) ・Oil temperature control thermistor(Lead wire length: 5m, 10m) ・Expansion board for main machine communication(Serial communication) 4 9 AKZ Specifications SERIES AKZ149 AKZ329 AKZ439 0.5 1.2 1.5 AKZ149 AKZ329 AKZ439 Oil Cooling Unit horsepower(HP) Model name Stan dard ーB ーC kW Heater Supply power*2 Circuit voltage Different voltage Stan specifications *3 dard ーT *9 ーH Cooling capacity(50/60Hz)*1 kW ー Different voltage Stan specifications *3 dard ーT *9 ーH ーB ーC 1.3/1.4 1 ー 3-Phase AC 200/200・220V 50/60Hz ー *3 3.8/4.3 1 ー 3-Phase AC 200/200・220V 50/60Hz Main circuit*3 Different voltage specifications *3 ーT *9 ーH ーB ーC 2.8/3.2 ー *3 1 ー 3-Phase AC 200/200・220V 50/60Hz *3 3-Phase AC 200/200・220V 50/60Hz DC12/24V Operating circuit 200V 50Hz 0.90kW/3.9A 1.29kW/4.1A 0.90kW/3.9A Max. power consumption 200V 60Hz 0.91kW/3.6A 1.32kW/4.2A 0.91kW/3.6A Max. consumption current 220V 60Hz 0.91kW/3.5A 1.43kW/4.2A 0.91kW/3.5A *10 1.43kW/4.8A 1.61kW/5.2A 1.43kW/4.8A 1.80kW/6.6A *10 ー *10 1.88kW/6.4A 1.43kW/4.6A 1.72kW/5.0A 1.43kW/4.6A 2.6kVA ー Transformer capacity 1.36kW/4.9A 1.49kW/4.8A 1.36kW/4.9A 1.88kW/6.1A 2.6kVA ー 2.6kVA Ivory white Exterior color Outside dimensions(H×W×D) mm 650×360×440 950×360×440 810×360×535 950×360×440 775×360×440 1075×360×440 965×360×535 1075×360×440 875×360×440 1175×360×440 1065×360×535 1175×360×440 AKZ 9 SERIES Equivalent to 0.4kW Compressor(Totally enclosed DC swing type) Equivalent to 0.75kW Cross-fin coil type Condenser Motor Propeller fan Oil pump Equivalent to 1.1kW Shell-end coil type Evaporator φ250、 54W φ300、 54W 0.4kW×4P Motor Theoretical discharge rate L/min Open pressure Specifications and range of use SynchroniTemperature zation type adjust (Selectable) Fixed type 12/14.4 24/28.8 0.5 0.6 MPa Room temperature or machine temperature *4 (Set to“Room temperature: Mode 3”by default) Standard Inlet oil temperature or outlet oil temperature (Set to“Inlet oil temperature”by default) Object to be controlled Synchronization range −9.9∼+9.9 against the standard temperature (Set at 0.0 by default) K Inlet oil temperature or outlet oil temperature Object to be controlled Range 5∼50 ℃ Compressor revolutions by inverter + Opening of electric expansion valve Refrigerant control Refrigerant(New refrigerant: R410A)*5 Filling amount kg Protection equipment Room temperature 0.49 0.72 0.98 A set of overcurrent relay(motor for pump), reverse-phase protection equipment, restart prevention timer, low room-temperature protection thermostat, high room-temperature protection thermostat, low oil-temperature protection thermostat, relief valve for pump, discharge tube temperature thermostat, condenser temperature thermostat, refrigerant leak detector, and inverter protection equipment. High-pressure switch(−C type only), compressor protection thermostat (−C type only), overheat prevention temperature thermostat(−H type only), boil-dry protection switch(−H type only), no-fuse breaker (−B type only) 5∼45 ℃ 5∼50 Inlet oil temperature ℃ Operating Oil viscosity mm2/s range Product external Discharge side pressure loss Suction side Usable oil 1.4∼200 (ISO VG2∼32) 0.5MPa or less −30.7kPa or less Lubricant, hydraulic oil of mineral oil(Not usable for hydraulic oil of ester phosphate, water, water-soluble liquid, drugs, food products, fuel, cutting liquid, grinding liquid, etc.) Rc3/4 Oil inlet Rc3/4 Connecting tube Oil outlet Rc1 1/4 Rc3/4 Rc1 1/4 Noise value(Value measured at 1m high in front, (A) value equivalent as measured in anechoic chamber)dB 62 IP2X kg 51 Molded-case circuit breaker(Rated current) A − 10 Items to be prepared by customer *8 Rc3/4 65 Ingress protection*6 Oil tank (Capacity) Rc1 1/4 Up down 14.7m/S2 ×2.5 hr (7.5∼100Hz sweep / 5 min.) Transport vibration performance*7 Mass Rc3/4 Rc1/4 (Plugged) Oil drain L 78 68 87 − − 15 56 83 − Molded-case circuit breaker(Rated current) A 73 − 20 64 92 − − 10 91 − 81 100 − − 10 − 20 − 10 (Required for types other than ーB type) Note)*1. The cooling capacity represents the value at the standard point (inlet oil temperature: 35℃, room temperature: 35℃, oil for use: ISO VG32) . The tolerance of the product is approx.±5%. *2. Be sure to use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the unit. The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us. *3. There are three types of different voltage specifications depending on the power source: −046, −047 and −048 units. −047 and −048 units deal with the different voltage by featuring a transformer. The main circuit voltage is the transformer’ s secondary side voltage of 200 VAC, 50/60 Hz. (−046 units have no transformer and therefore have the same external dimensions and mass as standard units. Their main circuit voltage is 220/230 VAC, 50/60 Hz.) *4. The machine temperature synchronous thermistor optionally available is required for this function. (Refer to Page 19 for details.) *5. The MSDS (Material Safety Data Sheet)of refrigerant R410A is attached to ーC type. *6. Electric component box ingress protection: IP54 or equivalent (However, use piping conduits etc. rated at least IP54 at wiring ports.) *7. The specifications for withstanding vibration during transport are those of a standard unit. *8. The molded-case circuit breaker is not supplied with this product. Please prepare it by yourself. *9. The yellow line on the tank oil level gauge shows the highest oil level and the red line the lowest oil level. *10. The maximum power consumption/maximum current consumption of different voltage specifications are shown in the tables below. ■AKZ149 Supply power Power/current 380V 2.1A 0.92kW 400V 1.9A 415V 0.93kW 50/60Hz 440V 1.8A 0.92kW 460V 480V 0.93kW 1.7A ■AKZ569 Supply power Power/current 380V 4.0A 400V 3.8A 415V 3.6A 50/60Hz 2.22kW 440V 3.4A 460V 3.3A 480V 3.1A 5 ■AKZ329 Supply power 380V 400V 415V 50/60Hz 440V 460V 480V ■AKZ439 Power/current 1.38kW 2.6A 1.44kW 2.5A 1.46kW 2.4A 1.38kW 2.3A 1.44kW 2.2A 1.46kW 2.1A ■AKZ909 Supply power Power/current 380V 7.1A 400V 6.8A 415V 6.5A 50/60Hz 4.28kW 440V 6.2A 460V 5.9A 480V 5.7A Supply power 380V 400V 415V 50/60Hz 440V 460V 480V Power/current 1.82kW 3.4A 1.89kW 3.3A 1.90kW 3.1A 1.82kW 3.0A 1.89kW 2.9A 1.90kW 2.7A AKZ569 AKZ909 2.0 3.0 AKZ569 AKZ909 Oil Cooling Unit horsepower(HP) Model name Stan dard ーB ーC ーT *9 *1 Circuit voltage 2 ー Stan dard ーT *9 ーB ーC ーH Different voltage specifications *3 3 ー 8.0/9.0 ー kW Supply power*2 Different voltage specifications *3 5.0/5.6 Cooling capacity(50/60Hz) kW Heater ーH 3-Phase AC 200/200・220V 50/60Hz Main circuit*3 ー 3-Phase AC 200/200・220V 50/60Hz *3 *3 3-Phase AC 200/200・220V 50/60Hz DC12/24V Operating circuit 200V 50Hz Max. power consumption 200V 60Hz Max. consumption current 220V 60Hz 2.22kW/7.7A 2.50kW/8.4A 2.30kW/7.6A 2.57kW/8.1A 2.30kW/7.3A 3.00kW/8.9A ー Transformer capacity 4.25kW/13.6A *10 *10 4.30kW/13.5A 4.28kW/13.0A 4.0kVA ー 6.0kVA Ivory white Exterior color Outside dimensions(H×W×D) mm 1110×470×560 1375×470×580 1410×470×560 1360×470×590 1220×560×680 1485×560×700 1520×560×680 1470×560×659 Equivalent to 2.2kW Brazed plate type Evaporator Cross-fin coil type Condenser Motor Propeller fan Oil pump AKZ 9 SERIES Equivalent to 1.5kW Compressor(Totally enclosed DC swing type) φ400、 100W 0.75kW×4P 0.7kW×4P Motor φ455、100W 0.75kW×4P 0.7kW×4P Open pressure 0.6 MPa Room temperature or machine temperature *4 (Set to“Room temperature: Mode 3”by default) Standard Inlet oil temperature or outlet oil temperature (Set to“Inlet oil temperature”by default) Object to be controlled Synchronization range −9.9∼+9.9 against the standard temperature (Set at 0.0 by default) K Inlet oil temperature or outlet oil temperature Object to be controlled Range 5∼50 ℃ Compressor revolutions by inverter + Opening of electric expansion valve Refrigerant control Refrigerant(New refrigerant: R410A)*5 Filling amount kg Protection equipment Room temperature 1.02 1.48 A set of overcurrent relay(motor for pump), reverse-phase protection equipment, restart prevention timer, low room-temperature protection thermostat, high room-temperature protection thermostat, low oil-temperature protection thermostat, relief valve for pump, discharge tube temperature thermostat, condenser temperature thermostat, refrigerant leak detector, and inverter protection equipment. High-pressure switch(−C type only), compressor protection thermostat (−C type only), overheat prevention temperature thermostat(−H type only), boil-dry protection switch(−H type only), no-fuse breaker (−B type only) 5∼45 ℃ 5∼50 Inlet oil temperature ℃ Operating Oil viscosity mm2/s range Product external Discharge side pressure loss Suction side Usable oil 1.4∼200 (ISO VG2∼32) 0.5MPa or less −30.7kPa or less Specifications and range of use SynchroniTemperature zation type adjust (Selectable) Fixed type 0.75kW×4P 30/36 Theoretical discharge rate L/min Lubricant, hydraulic oil of mineral oil(Not usable for hydraulic oil of ester phosphate, water, water-soluble liquid, drugs, food products, fuel, cutting liquid, grinding liquid, etc.) Rc1 1/4 Oil inlet Rc1 Rc1 1/4 Rc1 1/4 65 67 Up down 14.7m/S2 ×2.5 hr (7.5∼100Hz sweep / 5 min.) Transport vibration performance*7 Ingress protection*6 IP2X 82 kg Molded-case circuit breaker(Rated current) A Oil tank (Capacity) Items to be prepared by customer *8 Rc1 1/4 Rc1/4 (Plugged) Oil drain Noise value(Value measured at 1m high in front, (A) value equivalent as measured in anechoic chamber)dB Mass Rc1 Rc1 1/4 Connecting tube Oil outlet L Molded-case circuit breaker(Rated current) A − 15 − 100 115 145 − 50 97 − 132 122 20 − − 15 (Required for types other than ーB type) 175 − 70 − 20 (Required for types other than ーB type) Refer to Page 5 for explanatory notes. Range of use Note) 1. The mark ◎ shows the standard point. 2. Be sure to use the unit at the range of use specified in . ︵℃︶ Room temperature (The use outside the use range may cause unit failure.) 50 40 30 20 10 0 0 10 20 30 40 50 Inlet temperature (℃) 6 AKZ Cooling capacity characteristic chart SERIES 1,800 AKZ149 Cooling capacity (W) 1,600 Oil temperature = Room temperature +10℃ 1,400 Oil temperature = Room temperature 1,200 Oil temperature = Room temperature −10℃ 1,000 800 600 400 200 AKZ 9 SERIES 0 5 10 15 20 25 30 35 40 45 Room temperature (℃) Oil temperature = Room temperature +10℃ 3,500 Cooling capacity (W) Cooling capacity characteristic chart 4,000 AKZ329 3,000 Oil temperature = Room temperature Oil temperature = Room temperature −10℃ 2,500 2,000 1,500 1,000 500 0 5 10 15 20 25 30 35 40 45 Room temperature (℃) 6,000 AKZ439 Cooling capacity (W) 5,000 Oil temperature = Room temperature +10℃ Oil temperature = Room temperature Oil temperature = Room temperature −10℃ 4,000 3,000 2,000 1,000 0 5 10 15 20 25 30 Room temperature (℃) 7 35 40 45 AKZ569 7,000 Oil temperature = Room temperature +10℃ 6,000 Cooling capacity (W) 5,000 Oil temperature = Room temperature Oil temperature = Room temperature −10℃ 4,000 3,000 2,000 1,000 5 10 15 20 25 30 35 40 45 Room temperature (℃) Cooling capacity (W) 10,000 Oil temperature = Room temperature +10℃ 8,000 Oil temperature = Room temperature 6,000 Oil temperature = Room temperature −10℃ 4,000 2,000 0 5 10 15 20 25 30 35 40 Cooling capacity characteristic chart 12,000 AKZ909 AKZ 9 SERIES 0 45 Room temperature (℃) ■Solid line :When operated at 60Hz ■Broken line :When operated at 50Hz 1. The mark“○”shows the standard point. (Room temperature: 35℃ Inlet oil temperature : 35℃ Oil for use: ISO VG32) 2. The cooling capacity differs depending on conditions such as room temperature, inlet oil temperature, oil dynamic viscosity and other factors. 8 9 AKZ Outside dimension diagram Note)Refer to Page 5 for more details. The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not. SERIES With breaker (453) Standard specifications ⑰ ⑱ ⑲ ⑮⑯ Part No. Name 1 2 3 4 5 6 7 8 9 10 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter Name 11 12 13 14 15 16 17 18 19 20 Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate (160) ⑭ 90 ② ⑳ (10) Opposite side ⑦ (674) AKZ 9 SERIES Opposite side ⑧ ⑩ ⑪ (520) ⑫ Suction air ③ (13) 106 253 ① ④ 4-U slots (for fixing bolts) 60 AKZ149-H 60 12 5 216 30 14 123 12 15 410 440 66 328 R6 (at all 4 locations) 12 With heater Part No. Name 1 2 3 4 5 6 7 8 9 10 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right) Signal line inlet (Right / Left) Eye plate Air filter ⑱ Description Part No. Rc3/4 Rc1 1/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole Exhaust air ⑮⑯ ⑨ ⑥ ⑤ (413) ⑬ 38 (365) Rear face Name (160) ⑳ Opposite side ⑧ ⑩ ⑪ ⑫ 66 (13) Suction air (974) (820) 650 (1000) ④ ③ 328 ① ⑭ Opposite side ⑰ 406 ② 79 111 190 314 300 Description Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Heater box Heater drain Rc1/4 Plugged Air bleeder Rc1/4 Plugged ⑦ ⑧ 90 ⑲ 11 12 13 14 15 16 17 18 19 20 21 22 23 123 30 (50) 15 30 300 360 4-φ12 holes (for fixing bolts) 410 440 111 283 553 300 360 (505) Outside dimension diagram 30 ⑰ 9 Description (365) ⑦ ⑧ ⑨ (700) 650 φ28 Hole φ22 Hole φ25 Hole Part No. Exhaust air 38 ⑥ ⑤ Description Rc3/4 Rc3/4 Rc1/4 Plugged M6 plug Rear face (372) ⑬ Different voltages (without transformer) Compliance with CE 513 AKZ149(-B,-C,-046) Part No. Name 1 2 3 4 5 6 7 8 9 10 11 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter Room temperature thermistor ⑰ Description Rc3/4 Rc3/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole ⑱ ⑲ Rear face ⑭ ② ⑳ (10) 650 Opposite side ⑦ ③ (834) (680) Suction air 125 174 160 Red line 11L 123 30 105 4-φ12 holes (for fixing bolts) 300 410 20 66 535 110 360 AKZ149-047,-048 Different voltages (With transformer) Part No. (500) 1 2 3 4 5 6 7 8 9 10 ⑰ Name Description Rc3/4 Oil inlet Oil outlet Rc3/4 Oil drain Rc1/4 Plugged Oil pan drain M6 plug Control panel Electric component box lid Power supply inlet φ28 Hole φ22 Hole Signal line inlet Hanger Air filter ⑱ (420) ⑲ ⑮⑯ Part No. Name 11 12 13 14 15 16 17 18 19 20 21 22 Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Transformer Transformer box Description Outside dimension diagram ① Yellow line 15L AKZ 9 SERIES (860) 15L Rc3/8 Plugged KLA-50A HY-06T (160) ⑫ ④ Description (365) Opposite side ⑧ ⑩ ⑪ Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Oil tank Tank drain Oil level gauge* Oil hole-cum-air bleeder 673 ⑨ ⑥ ⑤ ⑬ 38 ⑦ ⑧ 90 (23) ⑮⑯ Name 12 13 14 15 16 17 18 19 20 21 22 23 24 *The yellow line on the oil level gauge shows the highest oil level and the red line the lowest oil level. (Keep the oil level between the yellow and red lines during use.) Exhaust air (372) Part No. 413 With tank 540 (635) AKZ149-T Exhaust air Rear face (365) ⑬ ⑥ ⑤ ⑭ *1 ⑩ ⑪ ② ⑳ (10) ⑫ 650 ③ Suction air 60 ① 813 ④ (13) 38 123 30 30 300 360 4-φ12 holes (for fixing bolts) (50) 15 410 ⑰ (13) 440 (13) 406 ⑧ ⑦ (270) 270 314 300 553 ⑨ 66 328 Note) *1. The hanging fitting is located below. Do not use this fitting for hanging. 10 9 AKZ Outside dimension diagram Note)Refer to Page 5 for more details. The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not. SERIES With breaker ⑰ ⑱ ⑮⑯ Rear face (372) Name 1 2 3 4 5 6 7 8 9 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate (645) ② ③ Suction air ① 106 15 300 12 AKZ329-H 60 5 216 60 R6 (at all 4 locations) 12 With heater ⑰ ⑱ ⑨ ⑥ ⑤ ⑬ Name 1 2 3 4 5 6 7 8 9 10 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right) Signal line inlet (Right / Left) Eye plate Air filter Description Rc3/4 Rc1 1/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole Exhaust air ⑮⑯ Rear face (413) Part No. 38 (365) Part No. 11 12 13 14 15 16 17 18 19 20 21 22 23 Name (160) ⑦ ⑧ ⑩ ⑪ ⑳ Opposite side ⑧ 775 ⑫ (1099) (945) (1125) 66 ④ Suction air (13) ③ 328 ① ⑭ Opposite side ⑰ 406 ② 79 111 190 314 300 Description Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Heater box Heater drain Rc1/4 Plugged Air bleeder Rc1/4 Plugged 90 ⑲ 66 328 30 123 12 410 440 4-U slots (for fixing bolts) 360 14 Outside dimension diagram 30 123 30 (50) 300 360 30 4-φ12 holes (for fixing bolts) 15 410 440 111 283 553 AKZ 9 SERIES ⑫ ④ 11 Description (10) Opposite side ⑦ (825) 775 Air filter Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate ⑳ (13) (505) Name 10 11 12 13 14 15 16 17 18 19 20 ⑭ Opposite side ⑧ ⑩ ⑪ Part No. (160) 90 ⑥ ⑤ φ28 Hole φ22 Hole φ25 Hole (365) ⑦ ⑧ ⑨ Description Rc3/4 Rc3/4 Rc1/4 Plugged M6 plug Exhaust air 38 ⑬ Part No. 253 ⑲ Different voltages (without transformer) Compliance with CE 648 (453) Standard specifications (799) AKZ329(-B,-C,-046) With tank 540 (635) AKZ329-T ⑰ ⑱ Part No. Name 1 2 3 4 5 6 7 8 9 10 11 12 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter Room temperature thermistor Unit faceplate Description Rc3/4 Rc3/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole Rear face ⑬ Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Oil tank Tank drain Oil level gauge* Oil hole-cum-air bleeder Description 20L Rc3/8 Plugged KLA-80A HY-06T (365) (160) ⑭ ② ⑳ (10) Opposite side ⑦ ③ 838 (835) (989) 775 ⑫ Suction air 443 ① 155 Red line 11L 123 30 4-φ12 holes (for fixing bolts) 300 105 410 AKZ329-047,-048 20 66 535 360 Different voltages (With transformer) Part No. (500) 1 2 3 4 5 6 7 8 9 10 ⑰ ⑱ 110 Name Description Rc3/4 Oil inlet Oil outlet Rc3/4 Oil drain Rc1/4 Plugged Oil pan drain M6 plug Control panel Electric component box lid Power supply inlet φ28 Hole φ22 Hole Signal line inlet Hanger Air filter Exhaust air ⑲ (420) ⑬ ⑮⑯ Rear face Part No. Name 11 12 13 14 15 16 17 18 19 20 21 22 Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Transformer Transformer box Description (365) ⑭ ⑥ ⑤ ⑩ ⑪ ② ⑳ *1 (10) 775 ⑫ Suction air ④ 38 ① ⑨ 270 123 30 30 300 360 4-φ12 holes (for fixing bolts) ⑧ ⑦ 15 410 ⑰ (13) 440 (13) 406 314 300 553 60 (13) 948 ③ (270) 204 190 Yellow line 20L Outside dimension diagram ④ AKZ 9 SERIES Opposite side ⑧ ⑩ ⑪ (1015) 38 ⑦ ⑧ ⑨ ⑥ ⑤ 90 (23) Exhaust air ⑮⑯ Name 13 14 15 16 17 18 19 20 21 22 23 24 *The yellow line on the oil level gauge shows the highest oil level and the red line the lowest oil level. (Keep the oil level between the yellow and red lines during use.) ⑲ (372) Part No. 66 328 (50) Note) *1. The hanging fitting is located below. Do not use this fitting for hanging. 12 9 AKZ Outside dimension diagram Note)Refer to Page 5 for more details. The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not. SERIES With breaker ⑰ ⑱ ⑲ ⑮⑯ Rear face (372) Part No. Name 1 2 3 4 5 6 7 8 9 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Description Rc3/4 Rc3/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole (365) Description 90 ② (10) (899) AKZ 9 SERIES Opposite side ⑦ (745) Air filter Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate ⑳ ⑫ (925) 875 Name 10 11 12 13 14 15 16 17 18 19 20 ⑭ Opposite side ⑧ ⑩ ⑪ Part No. (160) ⑦ ⑧ ⑨ ⑥ ⑤ Different voltages (without transformer) Exhaust air 38 ⑬ Compliance with CE ③ Suction air (13) ① 106 300 360 AKZ439-H 15 216 60 12 14 123 60 12 4-U slots (for fixing bolts) 5 30 30 (505) Outside dimension diagram ④ 708 (453) Standard specifications 253 AKZ439(-B,-C,-046) 12 ⑰ ⑱ ⑨ ⑥ ⑤ ⑬ Part No. Name 1 2 3 4 5 6 7 8 9 10 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right) Signal line inlet (Right / Left) Eye plate Air filter Description Rc3/4 Rc1 1/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole Exhaust air 38 (365) (160) ⑦ ⑧ Part No. 11 12 13 14 15 16 17 18 19 20 21 22 23 Name Description Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Heater box Heater drain Rc1/4 Plugged Air bleeder Rc1/4 Plugged ⑳ 90 ⑲ ⑮⑯ Rear face 66 328 R6 (at all 4 locations) With heater (413) 410 440 ⑩ ⑪ Opposite side ⑧ (1199) (1225) 875 ⑫ (1045) Suction air 66 (13) ③ 328 ① ④ 406 79 111 190 314 300 ② 123 30 (50) 13 30 300 360 4-φ12 holes (for fixing bolts) 15 410 440 111 283 553 ⑭ Opposite side ⑰ With tank 540 (635) AKZ439-T ⑰ ⑱ ⑲ (23) ⑮⑯ Part No. Name 1 2 3 4 5 6 7 8 9 10 11 12 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter Room temperature thermistor Unit faceplate Rear face 38 ⑦ ⑧ Name 13 14 15 16 17 18 19 20 21 22 23 24 Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Oil tank Tank drain Oil level gauge* Oil hole-cum-air bleeder Description 20L Rc3/8 Plugged KLA-80A HY-06T *The yellow line on the oil level gauge shows the highest oil level and the red line the lowest oil level. (Keep the oil level between the yellow and red lines during use.) ⑭ (160) ⑳ ② (10) Opposite side ⑦ (1089) Suction air ③ 898 (935) 875 (1115) ⑫ 443 ① 30 155 Red line 11L 123 AKZ439-047,-048 105 4-φ12 holes (for fixing bolts) 300 360 Different voltages (With transformer) 410 535 (500) ⑱ (420) ⑲ ⑮⑯ Rear face 66 110 Part No. 1 2 3 4 5 6 7 8 9 10 ⑰ 20 Name Description Rc3/4 Oil inlet Oil outlet Rc3/4 Oil drain Rc1/4 Plugged Oil pan drain M6 plug Control panel Electric component box lid Power supply inlet φ28 Hole φ22 Hole Signal line inlet Hanger Air filter Exhaust air Part No. Name 11 12 13 14 15 16 17 18 19 20 21 22 Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Caution plate Transformer Transformer box Description (365) ⑬ ⑭ ⑥ ⑤ ⑳ *1 ⑩ ⑪ ② (10) 875 ⑫ Suction air ④ 38 ① ⑨ 270 ⑧ ⑦ 406 314 300 553 60 (13) 1008 ③ (270) 190 204 Yellow line 20L Outside dimension diagram ④ AKZ 9 SERIES Opposite side ⑧ ⑩ ⑪ Part No. (365) 90 ⑨ ⑥ ⑤ φ28 Hole φ22 Hole φ25 Hole Exhaust air (372) ⑬ Description Rc3/4 Rc3/4 Rc1/4 Plugged M6 plug ⑰ 123 30 30 300 360 4-φ12 holes (for fixing bolts) 15 410 (13) 440 66 (13) 328 (50) Note) *1. The hanging fitting is located below. Do not use this fitting for hanging. 14 9 AKZ Outside dimension diagram Note)Refer to Page 6 for more details. The positions of the fixing bolt holes and the oil outlet/inlet ports are compatible with the AKZ 8 series, but the positions of the power supply/signal cable inlet ports are not. SERIES Standard specifications With breaker Name 1 2 3 4 5 6 7 8 9 10 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter ⑮⑯ (480) ⑬⑳ Inside face Rear face Description Rc1 1/4 Rc1 1/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole Description ⑭ ③ ① 597 Suction air 875 ⑫ (1135) 390 470 (517) AKZ569-H 60 327 306 60 15 530 560 (13) 75 110 240 12 (at all 4 locations) 22 With heater Part No. 1 2 3 4 5 6 7 8 9 10 ⑰ ⑱ ⑲ (480) ⑬⑳ Inside face ⑮⑯ Description ⑦ ⑧ 38 ③ 110 Suction air ① 513 (13) 110 94 (316) 300 Description 15 4-φ12 holes (for fixing bolts) 897 (1370) (1435) (1460) (1410) 1110 Name Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate Heater box Heater drain Rc1/4 Plugged Air bleeder Rc1/4 Plugged Opposite side ⑧ ④ 327 390 470 11 12 13 14 15 16 17 18 19 20 21 22 23 (425) (191) ⑫ 40 Part No. Exhaust air Rear face ⑨ ⑥ ⑤ ⑩ ⑪ Name Rc1 1/4 Oil inlet Oil outlet Rc1 1/4 Oil drain Rc1/4 Plugged Oil pan drain M6 plug Control panel Electric component box lid Power supply inlet φ28 Hole φ22 Hole Signal line inlet φ25 Hole Eye plate Air filter 530 560 132 22 5 30 (16) 4-U slots (For fixing bolts) 500 R6 Outside dimension diagram 40 30 213 AKZ 9 SERIES Opposite side ⑦ (980) Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate ② (13) Opposite side ⑧ (1160) 1110 Name 11 12 13 14 15 16 17 18 19 20 Exhaust air ⑦ ⑧ ④ 15 Part No. (425) (191) 38 ⑨ ⑥ ⑤ ⑩ ⑪ 90 ⑰ ⑱ ⑲ Different voltages (without transformer) Compliance with CE Part No. (517) AKZ569(-B,-C,-046) 102 240 331 ②⑭ (750) AKZ569-T With tank ⑰ ⑱ ⑲ 88 ⑮⑯ Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter Room temperature thermistor Description ⑨ ⑥ ⑤ ⑩ ⑪ (425) (191) 90 ⑭ Opposite side ⑦ ③ 862 ① 230 (281) 25 4-φ12 holes (for fixing bolts) AKZ569-047,-048 530 580 Different voltages (With transformer) (642) 1 2 3 4 5 6 7 8 9 10 ⑰ ⑱ (530) ⑬⑳ ⑮⑯ Name Description Part No. Name 11 12 13 14 15 16 17 18 19 20 21 22 Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate Transformer Transformer box Rc1 1/4 Oil inlet Oil outlet Rc1 1/4 Oil drain Rc1/4 Plugged Oil pan drain M6 plug Control panel Electric component box lid Power supply inlet φ28 Hole φ22 Hole Signal line inlet Hanger Air filter Description Exhaust air Rear face 38 Inside face ⑥ ⑤ ⑩ ⑪ 110 360 395 Part No. (425) ⑭ 90 (13) *1 ② ⑫ 1110 ③ (40) 500 (13) 390 470 4-φ12 holes (for fixing bolts) (40) (50) ⑰ 60 30 (13) 463 ⑨ ⑦ ⑧ 100 266 30 250 38 30 847 ④ 327 ① 1125 (1230) Suction air (202) 265 1140 (1400) (1245) Suction air Outside dimension diagram 327 390 470 50L Rc3/8 Plugged KLA-80A HY-06T ② (13) Opposite side ⑧ 1110 (1425) (1375) Description AKZ 9 SERIES Red line 37L ⑲ Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate Oil tank Tank drain Oil level gauge* Oil hole-cum-air bleeder *The yellow line on the oil level gauge shows the highest oil level and the red line the lowest oil level. (Keep the oil level between the yellow and red lines during use.) ⑦ ⑧ ④ 40 Name 12 13 14 15 16 17 18 19 20 21 22 23 24 φ28 Hole φ22 Hole φ25 Hole ⑫ Yellow line 50L Part No. Rc1 Rc1 1/4 Rc1/4 Plugged M6 plug Exhaust air 38 Inside face Name 1 2 3 4 5 6 7 8 9 10 11 Rear face (480) ⑬⑳ Part No. 75 110 530 590 (13) 240 Note) *1. The hanging fitting is located below. Do not use this fitting for hanging. 16 9 AKZ Outside dimension diagram Note)Refer to Page 6 for more details. The positions of the fixing bolt holes and the oil outlet/inlet ports are compatible with the AKZ 8 series, but the positions of the power supply/signal cable inlet ports are not. SERIES Standard specifications With breaker (635) ⑰ ⑱ ⑲ ⑮⑯ (570) Inside face ⑨ ⑥ ⑤ ⑪ ⑩ Name 1 2 3 4 5 6 7 8 9 10 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter ⑦ ⑧ φ28 Hole φ22 Hole φ25 Hole Description ⑭ ② (1245) ① 790 Suction air ③ 512 (1130) 30 620 22.5 635 680 (13) 88 123 257 12 (at all 4 locations) 22 60 With heater ⑰ ⑱ ⑲ (570) ⑮⑯ ⑬⑳ Name 1 2 3 4 5 6 7 8 9 10 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter Description Part No. 11 12 13 14 15 16 17 18 19 20 21 22 23 Rc1 1/4 Rc1 1/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole Exhaust air Rear face 38 Inside face Part No. ⑦ ⑧ ⑨ ⑥ ⑤ Name Description Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate Heater box Heater drain Rc1/4 Plugged Air bleeder Rc1/4 Plugged (545) (311) Opposite side ⑧ ⑪ ⑩ ② ⑫ ① Suction air 30 620 22.5 635 680 400 480 560 4-φ12 holes (for fixing bolts) 132 110 94 (316) 300 40 (13) 513 (1545) (1480) (1570) (1520) 1220 ③ 812 (635) AKZ909-H 5 30 (16) 60 Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate R6 Outside dimension diagram 4-U slots (For fixing bolts) 400 396 22 Name 11 12 13 14 15 16 17 18 19 20 (13) Opposite side ⑦ (1270) 1220 AKZ 9 SERIES 480 560 Part No. (545) (311) ⑫ 40 Description Rc1 1/4 Rc1 1/4 Rc1/4 Plugged M6 plug Opposite side ⑧ ④ 17 Part No. Different voltages (without transformer) Exhaust air 38 50 ⑬⑳ Rear face Compliance with CE 213 AKZ909(-B,-C,-046) 190 257 419 ②⑭ (870) AKZ909-T With tank 88 ⑰ ⑱ ⑲ ⑮⑯ 38 ⑨ ⑥ ⑤ ⑦ ⑧ 50 Inside face Name 1 2 3 4 5 6 7 8 9 10 11 Oil inlet Oil outlet Oil drain Oil pan drain Control panel Electric component box lid Power supply inlet (Right / Left) Signal line inlet (Right / Left) Eye plate Air filter Room temperature thermistor Description Part No. Name 12 13 14 15 16 17 18 19 20 21 22 23 24 Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate Oil tank Tank drain Oil level gauge* Oil hole-cum-air bleeder Rc1 Rc1 1/4 Rc1/4 Plugged M6 plug φ28 Hole φ22 Hole φ25 Hole Exhaust air Rear face (570) ⑬⑳ Part No. Description *The yellow line on the oil level gauge shows the highest oil level and the red line the lowest oil level. (Keep the oil level between the yellow and red lines during use.) (545) (311) Opposite side ⑧ Opposite side ⑦ ⑭ ② (13) AKZ 9 SERIES ⑪ ⑩ 70L Rc3/8 Plugged KLA-80A HY-06T ⑫ (1510) Suction air 1055 (1395) (1535) (1485) 1220 ③ 230 (281) 4-φ12 holes (for fixing bolts) 400 480 560 AKZ909-047,-048 650 700 25 Different voltages (With transformer) Part No. (747) (620) ⑬⑳ Inside face ⑮⑯ Description Part No. Name 11 12 13 14 15 16 17 18 19 20 21 22 Room temperature thermistor Unit faceplate Design faceplate Instruction faceplate Overall caution plate Electric schematic diagram faceplate Battery charge mark faceplate Cutting injury caution plate High temperature caution plate Model name nameplate Transformer Transformer box Description Exhaust air Rear face ⑥ ⑤ Name Rc1 1/4 Oil inlet Oil outlet Rc1 1/4 Oil drain Rc1/4 Plugged Oil pan drain M6 plug Control panel Electric component box lid Power supply inlet φ28 Hole φ22 Hole Signal line inlet Hanger Air filter 1 2 3 4 5 6 7 8 9 10 ⑰ ⑱ ⑲ 110 437 472 38 (545) ⑭ 50 *1 ⑩ ⑪ (13) ⑫ ② ① 38 620 (13) ⑦ ⑧ ⑨ 100 (250) (266) 30 (40) 30 400 480 560 4-φ12 holes (for fixing bolts) (40) (50) 60 30 (13) ⑰ 635 695 (13) 463 ④ 762 1040 (1380) 1220 ③ Suction air (202) 265 Red line 51L 40 ① Outside dimension diagram Yellow line 70L 777 ④ 88 123 257 Note) *1. The hanging fitting is located below. Do not use this fitting for hanging. 18 Optional part Thermistor(Compatible with all types of Oil Cooling Unit 9 series) ■Thermistor models and applications When this optional part is installed in the oil piping of the main machine, the thermistor detects the temperature to allow the control of oil temperature. Model Machine temperature synchronous thermistor AKZ 9-OP-K5 Length of lead wire L(m) Application Applicable (To be installed) model by you Shape 5m AKZ 9-OP-K15 15m Lead wire 5m 80 φ1.1 (φ4.5) φ8 25 Lead wire (φ4.5) R1/8 AKZ 9-OP-Y10 10m 80 27.5 For machine temperature synchronous control Attached to the surface of main machine body ( ) XHP-3 (Blue) SXH-001T-0.6 5m For machine temperature synchronous control Implanted in the main machine body ( ) Plug-in terminal AKZ 9-OP-A10 10m AKZ 9-OP-Y5 φ1.1 R1/8 AKZ 9-OP-A5 80 27.5 (φ4.5) AKZ 9-OP-K10 10m (φ5) Plug-in terminal (φ5) Thermistor Thermistor for oil temperature control Optional part Name AKZ 9 Series For return oil temperature control Installed in oil tube of the main machine ( ) Lead wire Thermistor characteristics: Resistance value … R25(Resistance value at 25℃)= 20kΩ, Tolerance: ±3% ■Instruction for installation and connection AKZ 9-OP-K Main machine body ( ) Rc 1/8 (To be machined on the main machine side) Drill holeφ8, 20 or more in depth Connect to Oil Cooling Unit x 2M Terminal box Nos. 30 and 31. Fill the hollow portion with silicon grease. Recommended grease: Heat dissipating grease No. KS609 made by Shin-Etsu Chemical Co., Ltd. AKZ 9-OP-A (Main machine body) Please prepare the band and mounting screws yourself. Connect to Oil Cooling Unit x 2M Terminal box Nos. 30 and 31. Keep this part in close contact with the main body and cover the part with putty. AKZ 9-OP-Y Rc 1/8 Screw seat Oil tube Connect to Oil Cooling Unit control board connector CN11. Replace this part with the oil outlet thermistor and operate in the outlet oil temperature control mode Nos. 1, 5 and 6. 19 9 AKZ SERIES ■Installation positions of additional oil temperature control thermistor (machine body or others) Machine temperature synchronous thermistor Installation position (No. 30/31 pin) Thermistor for oil temperature control Installation position (CN11) Control board Optional part Expansion board for main machine communication Communication method Model Installation position Applicable model Specification sheet No. Serial communication only AKZ9-OP-CS Installation plate inside electric component box AKZ149、AKZ329、AKZ439、AKZ569、AKZ909 PSP04664 Note)1. Refer to the specifications sheet for the communication procedure and specifications. ■Installation position for AKZ9-OP-CS(serial communication only) D-SUB 9 pin connector Overcurrent circuit breaker (Not featured on some types) AKZ9-OP-CS board Supplied lead wire AKZ9-OP-CS board Expansion board for main machine communication The following functions are enabled by mounting this option board on the Oil Cooling Unit and connecting it to the main machine: 1. The operation mode and the operation setting can be changed from the main machine side. 2. The alarm code and temperature data (machine temperature, room temperature, inlet oil temperature, outlet oil temperature, inlet and outlet differential temperature, inverter frequency) of Oil Cooling Unit can be read from the main machine side. Control board Connect to CN12 on the control board ・Dimensions of communication board (W×H): 40×50 ・The communication board is secured at four positions by locking support. 20 Supporting information Part names, functions and operation of control panel 1 5 2 11 3 6 4 7 NO. 8 9 10 Item Description Supporting information Part names, functions and operation of control panel 1 Power lamp (Green) 2 Error warning lamp (Red) 3 Timer mode lamp (Red) 4 Operation mode display 5 Operation mode / Data No. display Displays the current operation mode (Normal mode, Operation setting mode) or data number of the data currently displayed on the data display part. 6 Data display Displays various data. The data displayed differs depending on the operation mode and data number. 7 [SELECT]key Selects the operation mode. 8 [DOWN]key Decrements the value of the operation mode, data number and data by 1. When held for two seconds or longer, decrements the values by 10. 9 [UP]key Increments the value of the operation mode, data number and data by 1. When held for two seconds or longer, increments the values by 10. 10 [ENT](Determine) key Determines the operation mode, data number, and data to be changed. 11 Warning lamp (Green) The lamp is turned on while power is supplied. When an error occurs Level 1 alarm: The lamp keeps blinking Level 2 alarm: The lamp is turned on The lamp keeps blinking while the unit is at a stop in the timer mode. Displays the mode of the control panel When a warning occurs NORMAL: Normal mode SETTING: Operation setting mode MONITOR: Monitor mode TIMER SET:Timer setting mode Level 1 warning: The lamp keeps blinking. Level 2 warning: The lamp is turned on. ■Operation for change to each mode A mode can be changed by operating the key in general. To enter a special mode, hold down a number of keys in combination for more than 5 seconds. Hold down for more than 5 seconds. Turn on the power Operation lock mode Normal mode Operation setting mode Hold down for more than 5 seconds. Timer setting mode Auto tuning mode Hold down for more than 5 seconds. Monitor mode Parameter setting mode ■ The default setting is“Operation lock mode” . To start operation, perform the unlocking operation as shown above. CAUTION 21 ■ The default setting for operation on the standard unit is: Operation mode: 3 (Inlet oil temperature control, room temperature synchronization control) Differential temperature: 0.0 (K) 9 AKZ SERIES Supporting information Operation mode and setting method AKZ 9 Series Mode No. Mode name Description Setting temperature range Mode 0 Inlet oil temperature, fixed temperature control Keep the inlet oil temperature at the setting temperature within the range specified in the right column. Necessary optional part 5∼50℃ Mode 1 Outlet oil temperature or return oil temperature control Fixed temperature control Keep the outlet oil temperature or return oil temperature at the setting temperature within the range specified in the right column. 5∼50℃ Mode 3 Inlet oil temperature, room temperature synchronous control Keep the inlet oil temperature at the setting temperature within the range specified in the right column. Between Room temperature -9.9℃ and Room temperature + 9.9℃ Mode 4 Inlet oil temperature, machine temperature synchronous control Keep the inlet oil temperature at the setting temperature within the range specified in the right column. Between Machine temperature -9.9℃ and Machine temperature+ 9.9℃ Machine temperature synchronous thermistor Mode 5 Outlet oil temperature or return oil temperature control, room temperature synchronous control Keep the outlet oil temperature or return oil temperature at the setting temperature within the range specified in the right column. Between Room temperature -9.9℃ and Room temperature + 9.9℃ Mode 6 Outlet oil temperature or return oil temperature control Machine temperature synchronous control Keep the outlet oil temperature or return oil temperature at the setting temperature within the range specified in the right column. Between Machine temperature -9.9℃ and Machine temperature + 9.9℃ Oil temperature control thermistor (When return oil temperature is controlled) Oil temperature control thermistor (When return oil temperature is controlled) Machine temperature synchronous thermistor Oil temperature control thermistor (When return oil temperature is controlled) Note) 1. Modes 2, 7, and 8 cannot be used on this series. Note) 2. Refer to Page 19 for details of necessary optional parts. ■Setting procedure: AKZ Default setting: Set to“Mode: 3”and temperature to“0.0”. When you use your unit at a setting other than the default setting, change the setting following the procedure shown below. Hold down the key and key simultaneously for more than 5 seconds. 2 Select the“Setting”mode and press the key once. Change the mode Blinking 3 Press the or Press the [ENT] key to switch between “Mode” and “Data”. The number of the“Mode” is increased by one. key for mode setting. 4 Determine the value by pressing the The“Setting temperature” is reduced by 0.1. 5 Press the key. 7 To return to the“Normal”mode, press the or The“Setting temperature” is increased by 0.1. key for temperature setting. 6 Determine the value by pressing the key. key three times. Operation mode and setting method The number of the“Mode” is decreased by one. Change the setting temperature Blinking Supporting information 1 Power ON --- Release the operation lock mode before starting operation for the first time. Points checked in the monitor mode The following points can be checked in the monitor mode. Monitor No. Description Note Monitor No. Description Note 0 Machine body temperature【Th1】 *1 5 △T (Th4∼Th2) *1 1 Outlet oil temperature or return oil temperature【Th2】 *1 6 Cooling capacity control command value(%) − 2 Room temperature【Th3】 *1 7 Compressor inverter rotational speed(rps) − 3 Inlet oil temperature【Th4】 *1 8 Power consumption(kW) *3 4 Reserved【Th5】 *1 9 Extended DIN(hundreds digit), DOUT(tens digit)status *2 *1. If the thermistor is not connected or has a broken wire, −99.9 is displayed. *2. With the default setting, 0 is displayed. Note that display is enabled when parameter n020 is“1”or the optional communication expansion board is installed. *3. This is the value obtained by rough calculation under the following conditions (the error is around 20%): power supply voltage of 200 V, pump discharge pressure of 0.2 MPa (VG32: oil temperature 25℃). Contact us separately about pumpless units. 22 10 Remote control 11 13 Optional protection equipment 12 31 60 61 62 63 5 4 L1 L2 L3 A3P 66 S160 65 ∼ - Th-8 Th-7 Th-6 X2M 67 S9 SA X519 X500 2 6 S130 Option Th-9 Th-2 S5P −H type only Option Option Th-1 9 10 11 12 13 30 31 X4M M 3∼ M1P S0 MR30Y For external communications (serial) CN12 S10 For shipping adjustments Analog monitor - + ACDC Alarm output S179 +12V DCL2 - + 3 S171 Short-circuit line S172 Shortcircuit line Expansion board for main machine communication Thermistor for oil temperature control Machine temperature synchronous thermistor K1S S4T AKZ9-OP-CS A5P Th-9 Th-1 Part symbol −H type only Short-circuit line Magnetic contact coil K2M 23 IC600 Th300 −H type only X4M 24 95 96 AKZ9-OP-K5 AKZ9-OP-K10 AKZ9-OP-K15 AKZ9-OP-A5 AKZ9-OP-A10 AKZ9-OP-Y5 AKZ9-OP-Y10 Model θS2T S3PH CE type only CE type only S170 +15VE S185 S184 S183 S182 CN2 +12V LED300 - C550 C551 + FU550 + ∼ 3.15A 250V - - Power supply circuit DCL CN6 Inverter CPU normal - DCL1 Protection equipment input circuit S140 2 CN110 CN650 ∼ [Optional part] Name -047, 048 only 60 61 62 63 64 65 66 67 ∼ FU650 3.15A 250V CN103 R S T A2P Communication 60 61 62 63 64 65 66 67 Board communicating Control CPU normal X2M 9 10 11 12 13 30 31 CN10 CN11 Operational error prevention switch High-accuracy analog input SW0 Th-3 T1 U1 T2 V1 T3 W1 K1S Black (red) Black (white) Black L1 L2 L3 5 For external communication S150 S151 (parallel) X520 Relay control X510 Black Black Black LED_A LED140 R S T X530 Relay control S60 Photocoupler Surge absorber Power supply circuit FU511 FU512 FU513 6.3A 250V SA Expansion user I/O S90 S80 S200 A1P X501 Th-4 24 64 Y1E M Black Red Option A5P A4P T1R t°Black Red E1H t° t° −H type only F1UT F2UT U2 V2 W2 K2M R S T X3M Black (red) Black (white) Black For −B units only Black (red) Black (white) Black For connection Normal Pump operation Warning output of machine Error / Power failure synchronization thermistor OFF : Level 1 Alarm, level output ON : Level 2 30 X1M Black (red) Black (white) Black For −047 and −048 types MCCB Note) 1. If a thermistor for temperature control (Th-9) is used, the existing Th-2 at CN11 is to be replaced. 2. Refer to the electric schematic diagram of ach type for details. 9 Warning and operation signal [Power supply] Model Supply power Standard , 3∼200/200・220V −C, −B, 50/60Hz −T, −H 3∼220・230V -046 50/60Hz 3∼380・400・415V -047 50/60Hz 3∼440・460・480V -048 50/60Hz L1 L2 L3 L1 L2 L3 MCCB Tr Input Output 0V MR52Pa X3M MR30X L1 L2 L3 Electric schematic diagram Black Black Black Supporting information 23 MR30W Y2E M Th-Fin N=4 S172 CE type only θS2T M3F S5P S4T K2M X3M,X4M −047,048 MCCB (Different voltage Tr specifications, with transformer) X3M,X4M −H (With heater) S2T −C (CE compliance type) S3PH F1UT,F2UT E1H −B (With breaker) MCCB Circuit breaker Compressor protection thermostat High-pressure switch Thermal fuse Heater Magnetic contact Magnetic contact coil Overheat prevention temperature switch Boil-dry protection pressure switch Terminal block Circuit breaker Transformer Terminal block Additional part symbol Control board Inverter board Noise filter board Display board Condenser Connector Ferrite core Reactor Fuse Overcurrent relay Motor (Pump) Motor (Compressor) Motor (Fan) Machine temperature Th-1 synchronous thermistor (option) Th-2 Outlet oil temperature thermistor Th-3 Air (room temperature) thermistor Th-4 Inlet oil temperature thermistor Th-6 Discharge gas temperature thermistor Th-7 Condensation temperature thermistor Th-8 EV valve outlet temperature thermistor Th-9 Oil temperature thermistor (option) Fin temperature thermistor Th-Fin Th300 Box temperature thermistor Transformer T1R X1M,X2M Terminal block Y1E,Y2E Electronic expansion valve A1P A2P A3P A4P C CN,S,X COR DCL FU K1S M1P M2C M3F [Standard, −046 (different voltage specifications, without transformer)] M2C Yellow Red White M Black Brown DC Orange Blue Red Yellow M 3∼ Blue [Semi-standard types] Type name 6 CN7 CN20 CN18 U V W GND Vcc Hu Hv CN600 COR CN15 Supporting information Electric schematic diagram(Typical diagram) 9 AKZ SERIES Electric wiring connection instruction diagram 1 Power supply capacity … Refer to the max. power consumption and max. consumption current of the specification sheet of each type. 2 Connection to power supply terminal block(X1M, Tr) (1) (2) (1)In the case of the standard type and semi-standard type (−C, −H, −T, −046) , connect the line to X1M. (2)In the case of“with breaker” (−B)specifications, connect to the circuit breaker. (3)In the case of the semi-standard type(with transformer:−047, −048), connect the line to the terminal block supplied with the transformer. (3) 1.Screw terminal and wiring diameter L1 L2 L3 L1 L2 L3 U V W Wiring diameter Terminal Screw block terminal JIS cable IEC cable UL cable Series AKZ 149,329,439,569 AKZ 909 X1M M4 Breaker M5 X1M M5 Breaker M5 2.0mm2 or more 2.5mm2 or more AWG#14 or more 047: 380V 400 415 380 400 415 380 400 415 048: 440V 460 480 440 460 480 440 460 480 3.5mm2 or more 4.0mm2 or more AWG#12 or more Connect the lines to the terminals corresponding to the main power supply. 2. Use a round crimp-style terminal for connection. 3. The terminal block is for three poles and the earth wire is to be secured on the enclosure with a screw Unassigned(Do not connect to this terminal) For connection of optional protection equipment(OP) Remote control Unassigned(Do not connect to this terminal) Alarm level output (OFF: Level 1, ON: Level 2) For connection Error / Power failure of machine synchronization Pump thermistor Normal operation (Earth) DANGER 3 Connection to signal terminal block(X2M) Warning output 1. Always install an all-pole (3-pole) circuit breaker (to be prepared by you) of the specified capacity on the main power supply. *All contact distances must be at least 3 mm. 2. Always ground the unit. Since a noise filter is installed, there is a risk of electrical shock without proper grounding. 3. Before opening the electric component box, always turn off the power, and wait for 5 minutes until internal high voltage has been discharged. 4. Do not energize the equipment with the electric component box kept open. 9 10 11 12 13 30 31 60 61 62 63 64 65 66 67 MR30W CAUTION MR30X (X2M) MR30Y Interior of oil cooling unit 1. Straight crimp terminal and wiring diameter Wiring diameter Straight pin terminals * JIS cable IEC cable UL cable 0.25mm2∼1.25mm2 0.3mm2∼1.5mm2 AWG#22∼#16 4 Signal output time chart (1)Alarm/operation status output chart Remote operation (between【10】and【11】) Operation status ON Signal output Normal(NO contact) 60−61 Error / Stop(Power OFF) (NC contact) 60−63 Error level(NO contact) 60−64 Pump operation(NO contact) 61−62 Normal Level 1 error or Lock Normal Level 1 error or Lock OFF Power failure Level 2 (Power OFF) error Normal Level 1 error or Lock Normal Level 1 error or Lock Level 2 Power failure error (Power OFF) ON OFF ON OFF ON OFF ON OFF (2)Warning output chart Operation status Signal output Warning output(NO contact) CAUTION 66−67 Non-warning status Power failure Level 2 (Power OFF) error Electric wiring connection instruction diagram 2. Use a straight crimp-style terminal for connection. 3. Use stranded wires for electric connection. 4. The wiring size is 0.5 mm2 to 1.5 mm2 in the case of duplex cable according to IEC. If using stripped wire, make the stripped length 9 mm to 10 mm. *Recommended models and manufacturers: TGN TC−1.25−9T (NICHIFU Co., Ltd.) APA−1.25N (DAIDO SOLDERLESS TERMINAL MFG. CO., LTD.) 1. To avoid the effects of noise, connect the power wire by cutting it to the proper length so that no excess wire comes into contact with the control board or others. 2. To perform remote control, remove the short-circuit wire between [10] and [11] and install an operation switch(to be prepared by you). 3. The mode is set to“Lock mode(Stop mode)”by default. Before starting operation, follow the procedure to release the Lock mode from the operation panel. Refer to the operation manual for the unlocking procedure. 4. The unit is provided with a misoperation prevention switch (PROTECT) to reject setting from the operation panel. If you want to use this function, make the necessary setting referring to the operation manual. Supporting information MR52Pa Supporting information Warning status Power failure Level 2 (Power OFF) error ON OFF 1. The following electric wires can be used on the 3. For [10] to [13], please prepare contacts to meet terminal block for straight crimp-style terminals. the condition of minimum applicable load 12V DC Single wire: φ0. 57∼φ1. 44(AWG#22∼#16) and 5mA. 2 25mm2∼1. 25mm(AWG# 22∼16) 4. When the length of the thermistor to be connected Stranded wire: 0. 2. Load applicable to [60 - 64] and [66 - 67] is as follows: to [30] − [31] is longer than 10m, or the wiring is Min. applicable load: 10mV DC, 10μA or more routed in a poor noise environment, use shielded Max. applicable load: 30V DC, 2A(Resistance load) wire. 24 Supporting information Notes for installing external piping If the external pressure loss(site piping resistance) exceeds the specified use range, there may occur phenomena such as abnormal noise of the pump(relief noise, noise of cavitation) , decrease of cooling capacity and control failure of oil temperature. Keep the external pressure loss within the specified use range. ●Relationship between oil flow rate and external pressure loss An AKZ 9 series Oil Cooling Unit incorporating a pump of the circulation type has the characteristics shown below. When the external pressure loss (△p) is 0.5 MPa or less, the rated flow rate (Q0) is achieved, but when the external pressure loss exceeds 0.5 MPa, the flow rate becomes lower than the rated flow rate. 1. Suction-side piping Keep the suction vacuum pressure within the range between -30.7 and 0kPa. The use of a suction filter of 100 to 150 mesh is recommended. 2. Discharge-side piping Keep the pressure loss of the discharge-side piping at 0.5 MPa or less. 3. Do not install a stop valve on the suction or discharge side. When a stop valve must be installed on the discharge side out of necessity, use a 0.5Mpa relief valve along with the stop valve. 4. Calculation of piping resistance Determine the oil piping size by calculating the piping resistance according to the following equation: Good example Circulation volume or flow rate Q(L/min) Usable range Piping resistance △P=0.595 ×ν×Q×L/D4 (For use of general hydraulic oil and lubricant) Q0 Unusable range A B AKZ329・439・ 569・909 Q1 AKZ149 C 0 0.5 0.6 0.7 0.8 External pressure loss △P(MPa) Q (L/min) :Flow rate(Q0: Rated flow rate) △P (MPa) :External pressure loss A:Status when the external pressure loss is“0” B:Status when the external pressure loss is“0.5Mpa” (MPa) △ P:Piping resistance (mm2/s) ν:Dynamic coefficient of viscosity −Refer to the Viscosity / Temperature Chart. Q:Flow rate(L/min) L:Piping length(m) D:Internal piping diameter(mm) (Cracking pressure of relief valve) C:Status when the external pressure loss is large and the oil flow rate is“0” . ■Viscosity / Temperature Chart Dynamic viscosity Supporting information Note)Design the site piping to withstand a pressure of at least 1.0 MPa. mm2/s 10 20 -10 30 40 0 50 Temperature 60 70 80 10 20 90 30 Example of viscosity (dynamic coefficient of viscosity) 100 110 120 130 140 150 ° F 40 50 60 70℃ 10,000 In winter: 195mm2/s ISO VG32 Oil (temperature 5℃) 5,000 3,000 2,000 In summer: 29mm2/s ISO VG32 Oil (temperature 40℃) 1,000 Notes for installing external piping 500 400 300 200 150 68 100 75 46 50 40 30 32 20 22 15 10 10 9.0 8.0 7.0 5 6.0 5.0 2 4.0 3.0 2.0 -10 10 25 △P >0.5MPa ↓ The oil flow rate becomes Q1, lower than the rated flow rate. Bad example △P ≦0.5MPa ↓ The rated flow rate(Q0)is achieved. 0 20 30 40 10 20 50 60 70 80 Temperature 30 90 40 50 60 70℃ 100 110 120 130 140 150 ° F 9 AKZ SERIES Supporting information Notes for handling ●Important notes to be observed regarding the main machine side (machine tools and industrial machine) 1. When adverse transport conditions are expected in transporting the machine overseas or elsewhere, special precautions should be taken in the packaging and transportation method so as to avoid the application of excessive force on Oil Cooling Unit(this unit) . 2. Oil Cooling Unit(this unit)does not incorporate a flow switch for checking the oil supply and a temperature switch for abnormal supply of oil temperature(high temperature or low temperature) . So, please provide a protection device such as a flow switch and a temperature switch on the main machine side. Notes for operation and cooling capacity 1. Do not use Oil Cooling Unit for cooling a liquid at 50℃ or more. Start to operate Oil Cooling Unit at the same time as the main machine or before liquid temperature rises to 40℃. 2. Do not place an object that hinders ventilation within 500mm of the suction port or discharge port. 3. If the air filter is clogged, the cooling capacity is reduced. Clean the air filter(wash with hot water or clean with air)periodically once every two weeks to prevent clogging. Notes regarding liquid usable with Oil Cooling Unit 1. The notes are given in the table below.(○ symbol・ ・ ・Can be used, × symbol・ ・ ・Cannot be used) 2. Do not use the liquid listed below as“not usable” (Marked with“×” ) . Special notes Mineral hydraulic oil ○ × Coolant fluid ● Water-soluble cutting and grinding liquid ● Non water-soluble cutting and grinding oil × Ethylene glycol (Antifreeze liquid) × × Water(Industrial water) Inflammable liquid like fuel Liquid equivalent to special flammables, alcohol, first class petroleum and second class petroleum of the fourth group hazardous materials specified according to the Fire Defense Law × × Drugs Liquid for food products Notes for handling Nonflammable hydraulic oil ● Ester phosphate series ● Chlorinated hydrocarbon series ● Water - Glycol series ● W-O & O/W emulsion series (High-aqueous hydraulic oil) Supporting information Lubricant ・The third class petroleum and fourth class petroleum of the fourth group hazardous materials specified according to the Fire Defense Law, and oil equivalent to discoloration No. 1 according to the copper corrosion test method(JIS K2513)of petroleum products ・Oil equivalent to NAS 10 level according to the pollution level AKZ 9 Series Drinking water, water for cooling food products, etc. × 26 Supporting information Notes for handling *Before operating this unit, be sure to read the operation manual and properly understand it. ●Instructions for safe operation Signs and Instructions D A N G E R・ ・ ・Failure to observe the instruction may cause an imminent hazardous situation that may result in personal death or serious injury. ・ ・Failure to observe the instruction may result in personal death or serious injury. WARNING・ ・ ・Failure to observe the instruction may result in personal injury or damage to the property. CAUTION・ 1 General instructions [ DANGER] ʱUse the equipment only in accordance with the intended specifications(specified in brochure, specification sheet, operation manual, caution plate). [ DANGER] ʲNever operate the equipment in an explosive atmosphere [ DANGER] ʳDo not disassemble, repair or modify the equipment by yourself. [ DANGER] ʴAlways comply with the laws and regulations for safety(Industrial Safety and Health Law, Fire Defense Law, JIS B 8361 Guidelines of Hydraulic System). [ WARNING] ʵCaution in the event of refrigerant leak ・Ventilate a room adequately(to avoid the risk of suffocation) . ・Avoid direct contact of the refrigerant with skin(to avoid the risk of frost injury) . ・In the event of inhalation of a great deal of refrigerant, contact with skin, and refrigerant in the eye, seek medical attention immediately. [ WARNING] ʶIn the event of an abnormal condition, stop operation promptly, investigate the cause of the problem and take appropriate remedial measures. [ CAUTION] ʷDo not use the unit in atypical environments (locations subject to high temperatures, high humidity, or [ CAUTION] ʸInstall a flow switch and temperature switch on the main machine to protect the main shaft and others. [ CAUTION] ʹDo not get on the equipment or place an object on the equipment. a lot of dust, contamination, particulate matter, steam, oil mist or corrosive gases: H2S,SO2,NO2 or CL2). 2 Instructions for transportation Supporting information [ DANGER] ① When hoisting the equipment, check its weight and use the eye plates and hangers on the equipment properly. [ WARNING] ② Do not get approach the equipment while it is being hoisted and moved. [ CAUTION] ③ When moving the equipment, take appropriate measures for fall prevention. [ CAUTION] ④ Do not tilt the equipment 30 degrees or more while transporting the equipment(including during storage). 3 Instructions for installation [ WARNING] ① Install the equipment on a rigid, level foundation and secure it appropriately. [ CAUTION] ② Do not place an object near the suction port and discharge port of the equipment. 4 Instructions for wiring and piping installation [ DANGER] ① Wiring and piping installation should be performed by a person with specialized knowledge and skills. [ DANGER] ② Always use a commercial power supply for the power source. (The use of an inverter power supply may cause burn damage). [ DANGER] ③ Connect the wiring for power supply in accordance with the electric wiring instruction diagram of the specification sheet and operation manual. Notes for handling [ DANGER] ④ Ground the equipment properly. [ WARNING] ⑤ Install the wiring in accordance with the standard by checking the electric schematic diagram. [ CAUTION] ⑥ Always install a dedicated breaker (molded case circuit breaker) appropriate for the capacity of Oil Cooling Unit on the main power supply on site. [ CAUTION] ⑦ Check to see that the oil piping has the pressure resistance of 1MPa or more and install the piping appropriately. 5 Instructions for trial run [ CAUTION] ① Check to see that the main machine is in a safe status(not activated)before starting the trial run. [ CAUTION] ② Check to see that the oil piping and electric wiring are correctly connected to the main machine and that there is no looseness in connections and joints. [ CAUTION] ③ Disable the operation lock of the equipment(Oil Cooling Unit)before starting the main machine. [ CAUTION] ④ Check to see that the required amount of oil is in the oil piping system and that the piping is not blocked in the middle. 6 Instructions during operation [ DANGER] ① Do not splash water or liquid on the equipment. [ WARNING] ② Do not push your finger or an object into gaps of the equipment. [ CAUTION] ③ Do not touch the heated exhaust port of the equipment. 7 Instructions for maintenance and inspection 27 [ DANGER] ① Perform maintenance and inspection with the equipment kept open. Working in a closed status may result in suffocation due to the leak of refrigerant. [ DANGER] ② Always turn off the main power supply before starting maintenance and inspection. [ DANGER] ③ Wait for five minutes after turning off the main power supply and start maintenance and inspection operation. [ DANGER] ④ Do not operate the equipment with the cover of the equipment opened. [ CAUTION] ⑤ Wear protective gear such as gloves and an eye protector when performing maintenance, inspection and cleaning. [ CAUTION] ⑥ Clean the air filter periodically(once every two weeks in general) . [ CAUTION] ⑦ Keep oil cleanliness to NAS 10 level or less according to the pollution level. [ CAUTION] ʸCheck the oil level in the tank and ensure that it is between the yellow line and the red line. [ CAUTION] ʹInspect the underneath (drain pan) of the oil cooling unit once every six months, and if oil has accumulated, discharge it through the oil drainage port. 9 AKZ SERIES Supporting information Method of selection of Oil Cooling Unit Unit conversion formula ● 1kW=860kcal/h 1.Select Oil Cooling Unit having a cooling capacity 20 to 30% larger than the heat release value from the machine tool. 2.Since the cooling capacity of Oil Cooling Unit varies with the change of liquid temperature(inlet liquid temperature)and room temperature, it is necessary to clarify the liquid temperature and room temperature conditions to select appropriate Oil Cooling Unit. 3.Three methods are shown below as a guide for estimating the heat release value from the machine tool. For determining the heat release value eventually, it is necessary to conduct tests and determine the exact heat release value for selecting appropriate Oil Cooling Unit. ●Calculation method of heat release value from main machine for the selection of appropriate Oil Cooling Unit(as a general guide) In the case of cooling of main shaft of machining center ●Method 1: To estimate the heat release value from the temperature difference between the supply oil and return oil Q=2.778×10 -7Cp・γ・Vs・△T T1℃ V sm 3/h Q : Heat release value (kW) ・ ・ ・1967.4J/kg℃ Cp : Constant pressure specific heat(J/kg℃) (kg/m3) ・ ・ ・876kg/m3 γ : Weight volume ratio T2℃ Oil Cooling Unit (m3/h) Vs : Oil flow rate (℃) ・ ・ ・T2ーT1 △T: Temperature difference M E.g.)When“Vs”is 18m3/h(30L/min)and“△T”is 5℃ Main machine Q=2.778×10-7×1967.4×876×1.8×5 Oil tank =0.479×1.8×5≒4.3kW Find the maximum gradient of oil temperature increase To find the maximum gradient of the oil temperature, it is necessary to measure △t every one minute during the first 10 minutes. Tank oil temperature t1 Q=2.778×10 -7Cp・γ・V・△t/H (kW) Q : Heat release value ・・・1967.4J/kg℃ Cp : Constant pressure specific heat(J/kg℃) (kg/m3) ・ ・ ・876kg/m3 γ : Weight volume ratio t2 (m3) V : Total oil quantity 0 0.5 1.0 1.5 2.0 2.5 3.0 Time(h) (℃) ・ ・ ・t 1ーt △t : Temperature difference 2 (h) H : Time E.g.)When the total oil quantity is 300L(0.3m3)and“△t” is 10℃. Q=2.778×10-7×1967.4×876×0.3×10 =0.479×0.3×10≒1.4kW ●Method 3: When motor output loss is considered to be the heat release value Q : Heat release value (kW) Q=H・ η 100 H : Motor output (kW) …For driving the main shaft Method of selection of Oil Cooling Unit Oil temperature(℃) Ambient temperature ( ) Supporting information ●Method 2: To estimate the heat release value from the increase rate of oil temperature in the tank η : Motor output loss (%) E.g.)When the output loss is 30% for the motor output 7.5 kW → The output loss is 30% or so in general(Cooling of main shaft head) Q=7.5×0.3=2.3kW 28 Supporting information Table of history of Oil Cooling Unit for cooling main shaft(Circulation type) AKS→AKZ Horsepower Cooling capacity HP W 10,000 9,500 3.0 Old New AKS303K AKS303AK ◇ ◇ AKZ306 AKZ(S)907 ◇ 9,000 ◇ AKZ908 AKZ909 ◇ ◇ 8,500 8,000 7,500 7,000 6,500 6,000 5,500 2.0 5,000 AKZ206 ☆ ☆ AKS205K AKS203K AKS203AK ☆ Supporting information 1.2 AKZ(S)437 AKZ438 ◎ 3,500 2,500 AKS100Z AKS105K AKS105AK AKS103K AKS103AK AKS104K □ □ □ □ ■ AKZ106 □ 1,500 Table of history 1,000 0.3 ☆ ◎ AKZ439 ◎ AKS53K AKS54K △ △ AKS54AK AKS55K △ AKZ(S)327 AKZ328 □ □ ※ AKS55AK AKZ(S)147 △ △ AKS33K AKS35K AKS35AK ○ ○ ○ AKZ329 □ □ AKZ148 AKZ149 ○ ○ AKZ(S)257 2,000 0.5 ☆ 4,000 3,000 1.0 ☆ AKZ569 ☆ 4,500 1.5 AKZ(S)567 AKZ568 ○ 500 0 Series name AKS 3 series AKS 4 series AKS 5 series AKS-Z AKZ 6 series AKZ 7 series AKZ 8 series Sales starting time − '87.5 '86 '87 '88.1∼10 '98.12 '88 Discontinuation time '87.5 '02.3 '88 '88 '93.3 '02.3 '97.3 ON−OFF type '96.8∼10 '01.10∼'02.2 '02.9 '05.3 '02∼ Conventional type AKZ 9 series '10∼ '12∼ Current model Inverter type Note)1. The larger the last number of a model name, the newer the series (For instance, AKS35K is newer than AKS33K) . In addition, a model having the last alphabetic characters“AK”is newer than a model ending with“K”only. (For instance, AKS35AK is newer than AKS35K) . 2. The cooling capacity is represented by the value at the standard point and at 60 Hz for all models. 3. The dimensions of the equipment may be changed on a newer type and older type on some models. Please check the dimensions on the brochure and specification sheet(outline drawing)for selecting your equipment. When you are about to buy new equipment due to a failure of the equipment or for other reasons, please check the conditions of new equipment and select an appropriate type. 4. All the models have been changed to the inverter type since 2002. 5. AKSZ (S) “7”series uses new refrigerant R407C, AKZ“8” , AKZ“9”series uses new refrigerant R410A, and all other models use R22. 6. Existing units of 1HP class(AKS105AK, AKZ (S)257 class)were integrated into AKZ328 of 1.2HP class. 29 9 AKZ SERIES Supporting information Daikin Oil Cooling Unit service network What Daikin can offer as a global manufacturer of air conditioning equipment Daikin can offer you speedy delivery and reliability through a broad-based network in seven countries and regions throughout the world. Korea U.S. Japan China India Taiwan Thailand Singapore Please contact Daikin Sales Counter for servicing of Oil Cooling Unit in countries outside Japan. Daikin is ready to offer you service in conjunction with the sales agents of our Air-conditioning and Hydraulic Divisions located in seven countries and regions worldwide. Country/Region Locations Beijing Shanghai China Shanghai Korea Seoul Taiwan Taipei Singapore Singapore Thailand Bangkok India New Delhi U.S. Illinois 大金空調技術(上海)有限公司 DAIKIN AIR CONDITIONING TECHNOLOGY (SHANGHAI) CO.,LTD. 大金空調技術(広州)有限公司 DAIKIN AIR CONDITIONING TECHNOLOGY (GUANGZHOU) CO.,LTD. ◎ 大金工業株式会社 上海事務所 液圧控制課 DAIKIN SHANGHAI OFFICE OIL-HYDRAULICS DIV. ◎ KD HYDRAULICS,LTD. Service network Guangzhou Company name 大金空調技術(北京)有限公司 DAIKIN AIR CONDITIONING TECHNOLOGY (BEIJING) CO.,LTD. Supporting information Overseas service network HO TAI DEVELOPMENT CO.,LTD. DAIKIN ASIA SERVICING PTE. LTD. SIAM DAIKIN SALES CO., LTD. DAIKIN AIR CONDITIONING INDIA PVT.LTD DELHI BRANCH ◎ ALL WORLD MACHINERY ◎Sales agents of hydraulic equipment. Others are the sales agent of air conditioning equipment. (As of July 31, 2012.) 30 9 AKZ SERIES Osaka Office YODOGAWA PLANT 1-1,Nishi-Hitotsuya,Settsu,Osaka 566-8585,Japan Home Page: http://www.daikinpmc.com/en/ ●Contents in this catalog are subject to change for improvement without prior notice. GK245 (2012.08.030) KS.VV.MD