Environmentally Friendly Inverter Oil Cooling Unit

Transcription

Environmentally Friendly Inverter Oil Cooling Unit
AKZ
RoHS Compliant
9 SERIES
Use of new refrigerant R410A
I N D E X
AKZ 9 series
Features
P1∼2
Principle/
Piping system diagram
P3
Description of
model symbols
P4
Specifications and
range of use
P5∼6
Cooling capacity
characteristic chart
P7∼8
Outside dimension
diagram
P9∼18
Optional parts
Thermistor
P19
Expansion board for main
machine communication
P20
Supporting information
Control panel/Operation
mode/Setting method
P21∼22
Electric schematic
diagram
P23
Electric wiring connection
instruction diagram
P24
Notes for
handling
P25∼27
Method of
selection
P28
High-accuracy, Energy-saving, Compact
Table of history
P29
Environmentally Friendly
Inverter Oil Cooling Unit
Service network
P30
9
AKZ
SERIES
Oil Hydraulic Division
Oil Hydraulic Equipment
9
AKZ
SERIES
Circulation type
AKZ 9 SERIES
RoHS Compliant
Features
Features
Further Evolution of High-accuracy Temperature Control
Achieve high energy-saving performance
■Our acclaimed ±0.1℃ oil temperature control has
been extended to cover an even wider range.
■Achieve high energy-saving performance with the
adoption of a Daikin original IPM motor and R410A
refrigerant for high COP characteristics.
■The cooling capacity resolution in the low-load
range has been improved through optimal control
of the compressor and electronic expansion valve.
■The power consumption
can be checked on
Reduction of
the operation panel. approximately
Reduction of
approximately
*2
45%
*2
20%
Expansion of cooling capacity control range
100
Main machine
heating generation
Power consumption (*1)
■Control with loads from 0% (no load) to 100% achieved
High load
Low-load
No load
Time
80
60
40
20
0
■AKZ 9 series
Non-inverter
unit(Daikin)
Outlet oil temperature control
AKZ 8
series
AKZ 9
series
*1. Comparison taking a non-inverter unit to have a power consumption of 100
*2. Measured during Daikin’
s model operation patterns
Target temperature
±0.1℃
Achieve low-noise operation in the low-load range
Note)Pattern diagram with the heating load stabilized at 0 - 100%
(Comparison with Daikin unit)
AKZ 8
AKZ 9
59.5dB(A) RoHS Compliant
*
58dB(A)
Corresponding value in anechoic chamber (with AKZ 439 class)
■Complies with the RoHS Directive, e.g. by adopting
printed circuit boards with lead-free solder.
■Noise level also reduced in line with load reduction
*At room temperature of 25 and thermal load of 1 kW
Compact design of top class in the industry
*Compared with AKZ 439 class(Unit: mm)
7series
9series
8series
The AKZ 9
series
875
More
compact
990
1,020
comes top
in the
industry
440
440
360
1
360
360
440
Features
Functions featured
■The ingress protection of the control box has been upgraded
(equivalent to IP54).
■Refrigerant gas leakage detection alarm function
An alarm signal is output when the refrigerant gas
would be leaked (as cooling circuit failure).
■Oil temperature warning function
A warning signal can be output when the oil temperature or air
temperature strays outside arbitrarily setting range.
■Electronic components resistant to sulfidization have been adopted.
Higher durability for long-distance transportation
■Auto tuning function
This function substantially cuts the time taken for
adjustment during trial operation by automatically setting
the gain when oil temperature control is not stable in the
factory setting status or when optimization is required.
■The specifications for withstanding vibration during transport
have been upgraded to reflect actual transportation conditions.
Five types of semi-standard specification units in addition to
the standard type to achieve shorter product delivery terms
With heater With tank
With breaker
■999-hour timer function (ON timer)
The operation start time can be set from 0 to 999
hours in one-hour units.
Different
voltages
Compliance
with CE
New functions for ease of use
■Preventive maintenance function
●A warning signal is output to notify that maintenance is
required when the air filter or condenser becomes clogged.
●If the thermistor fails (out of control), emergency operation is
possible by selecting another operation mode.
This function minimizes the factors of line stoppages.
Easy monitoring of operating status
■The room temperature, inlet and outlet oil temperatures and other internal
data can be monitored at a personal computer using Hybrid-Win*.
This data can be displayed collectively, making it easy to grasp the
operating status.
Improved operability/maintainability
■The control panel has been revamped. Data is now displayed
in an easier-to-understand format with more digits space.
The power consumption is also displayed (new function).
■The newly adopted plug-in terminal block has enabled
tool-less connection of signal cables (simple connection).
*Hybrid-Win is a software tool for monitoring the internal status of the unit using a personal computer.
You can download the tool and its instruction manual free of charge from
the website (http://www.daikinpmc.com) after registering as a user.
*The communications cable and the monitor harness must be purchased separately.
RS232C
communications cable
Features
Individual
specifications for
general purpose
are set as
semi-standard
types
AKZ 9 SERIES
Reinforce durability for mist or dust in the severe condition of factory
Monitor harness
for oil cooling units
■The increased pitch of the condenser’
s fins suppresses
clogging and makes cleaning easier.
(1.5 mm previously → 1.8 mm)
Applications
■Example of major applications
Built-in
motor
Machine tools:Machining center, NC lathe, grinding machine,
NC specialized machine,
NC electric discharge machine, etc.
Industrial machine:Molding machine, press, etc.
Cooling of cooling oil
Cooling of periphery of built-in motor
● Minimize the thermal displacement of spindle
● Minimize the thermal displacement of column
● Prevent temperature rise of motor coil
Spindle
Cooling of hydraulic oil
Gearbox
Column
Cooling of lubricant
Cooling in gear box
Temperature(viscosity)control
● Minimize the thermal displacement of spindle
● Minimize the thermal displacement of column
● Prevention of deterioration of hydraulic oil(Longer life)
● Stabilized operation of actuator
Tool
M
Hydraulic unit
Workpiece
Bed
Example of use at machining center
2
9
AKZ
SERIES
Principle and overall system diagram
Control board
Inlet oil temperature thermistor(To *1)
Outlet oil temperature thermistor(To *2)
Oil temperature control thermistor(To *3)
〈Optional part〉 Room temperature thermistor(To *4)
Machine temperature
synchronous thermistor(To *5)
〈Optional part〉
Pressure reducing mechanism
B
E
Principle and overall system diagram/series piping system diagram
Bypass mechanism
M
Oil outlet
(Oil)
︵ Cooler
︶
Evaporator
*4
D
Fan
Condenser
(Suction air)
AKZ 9 SERIES
C
*5
*2
Machine tools
*1
Oil inlet
*3
M
(Refrigerant)
A
Oil pump
(Compressor)
Tank
Note)1. Refer to Pages 19 and
20 for optional parts.
2. Refer to Pages 21 and
22 for detailed setting
and others.
【Refrigerating cycle】
A:Refrigerant gas is converted into compressed gas at high temperature and high pressure by a compressor so that gas can be easily cooled and liquefied by a condenser.
B:In the condenser, the gas at high temperature and high pressure made in the compressor is cooled with air and converted into liquid at high temperature and high pressure.
C:The pressure reduction mechanism reduces the pressure of the liquid at high temperature and high pressure and converts it into liquid at low temperature and low pressure
by squeezing it so that it can be easily evaporated in a cooler.
D:In the cooler, liquid at low temperature and low pressure made in the pressure reduction mechanism removes heat from oil, evaporates(cools oil),
and is converted into gas at low temperature and low pressure.
E:The bypass mechanism controls the cooling capacity at low loads by adjusting the volume of gas at high temperature and high pressure supplied to the cooler.
9
AKZ
SERIES
Series piping system diagram
Electronic
expansion
valve
Control board
*1
*2
*3
*4
*5
Filter
Evaporator
Room
temperature
thermistor
*4
Electronic
expansion valve
Outlet temperature
thermistor
*5
Outlet oil
temperature
thermistor
Oil outlet
Plugged
High-pressure
S3 switch
PH (-C type only)
Oil drain
Condenser
Low pressure
gauge port
*3
Condensation
temperature
thermistor
Compressor protection
thermostat
(-C type only)
Fan
Hot gas
bypass valve
M
Filter
*2
Discharge gas
temperature thermistor
Oil
pump
M
Relief valve
Spindle of main machine
S2T
MC
compressor
*1
Inlet oil
temperature
thermistor
Oil inlet
Accumulator
Tank of main machine
3
9
AKZ
SERIES
Description of model symbols
※※
9
-
※※※
1
2
3
4
5
Oil cooling unit identification code
4
2
5
Symbol of series (Symbol to represent model change)
6,7,8,9 ……
Symbol for semi-standard types (B,C,H,T)
B :With breaker
C:Compliance with CE
H:With heater
T :With tank
046:Different voltage AC220,230V
50/60Hz
047:Different voltage AC380,400,415V 50/60Hz
048:Different voltage AC440,460,480V 50/60Hz
Or, a serial number (three numerical digits)
Non-standard specifications to meet individual requirements that are not covered
by the semi-standard specifications
* Contact us separately about special specifications (UL compliance, tropical treatment, etc.).
Specifications of standard, semi-standard, and non-standard types
Description of model symbols
3
:Used for units with a semi-standard specification or
a combination of semi-standard specifications
5 below is a serial number,
Single letter :When ■
the semi-standard specification is identified here with
a single letter of the alphabet.
Cooling capacity (kW) × 10
Indicates ten times the cooling capacity
Examples: 14, 32, 43, 56, 90,
where 14 indicates a cooling capacity of 1.4 kW
Specification identification code
-
AKZ : High-accuracy inverter oil cooling unit
[Circulation type, for spindle and lubricant]
AKZ 9 SERIES
1
AKZ
■AKZ 9(Circulation type)
Standard type Semi-standard Non-standard
○
○
○
○
B
C
046
047
048
H
With heater
T
With tank
○
Discharge pressure (oil) : 0.98 MPa
○
Discharge pressure (oil) : 1.47 MPa
○
Use of twin pump
○
Specified painting color
○
With expansion board for serial communication
Use of low-viscosity oil
Discharge pressure (oil) : 0.5 MPa
With timer
With outlet temperature sensor
With breaker
Compliance with CE
Without transformer
Different
voltages
With transformer
Remarks
Viscosity of oil for use:1.4 ー 200 mm2/S
999-hour timer
European Safety Standard
AC220,230V
50/60Hz
AC380,400,415V 50/60Hz
AC440,460,480V 50/60Hz
Unit with separately installed pump
Unit with separately installed pump
Unit with separately installed pump
■Optional parts(Refer to Pages 19 and 20)
・Machine temperature synchronous thermistor(Lead wire length: 5m, 10m, 15m)
・Oil temperature control thermistor(Lead wire length: 5m, 10m)
・Expansion board for main machine communication(Serial communication)
4
9
AKZ
Specifications
SERIES
AKZ149
AKZ329
AKZ439
0.5
1.2
1.5
AKZ149
AKZ329
AKZ439
Oil Cooling Unit horsepower(HP)
Model name
Stan
dard
ーB ーC
kW
Heater
Supply power*2
Circuit voltage
Different voltage Stan
specifications *3 dard
ーT *9
ーH
Cooling capacity(50/60Hz)*1 kW
ー
Different voltage Stan
specifications *3 dard
ーT *9
ーH
ーB ーC
1.3/1.4
1
ー
3-Phase AC 200/200・220V 50/60Hz
ー
*3
3.8/4.3
1
ー
3-Phase AC 200/200・220V 50/60Hz
Main circuit*3
Different voltage
specifications *3
ーT *9
ーH
ーB ーC
2.8/3.2
ー
*3
1
ー
3-Phase AC 200/200・220V 50/60Hz
*3
3-Phase AC 200/200・220V 50/60Hz
DC12/24V
Operating circuit
200V 50Hz 0.90kW/3.9A 1.29kW/4.1A 0.90kW/3.9A
Max. power consumption
200V 60Hz 0.91kW/3.6A 1.32kW/4.2A 0.91kW/3.6A
Max. consumption current
220V 60Hz 0.91kW/3.5A 1.43kW/4.2A 0.91kW/3.5A
*10
1.43kW/4.8A 1.61kW/5.2A 1.43kW/4.8A
1.80kW/6.6A
*10
ー
*10
1.88kW/6.4A
1.43kW/4.6A 1.72kW/5.0A 1.43kW/4.6A
2.6kVA
ー
Transformer capacity
1.36kW/4.9A 1.49kW/4.8A 1.36kW/4.9A
1.88kW/6.1A
2.6kVA
ー
2.6kVA
Ivory white
Exterior color
Outside dimensions(H×W×D) mm 650×360×440 950×360×440 810×360×535 950×360×440 775×360×440 1075×360×440 965×360×535 1075×360×440 875×360×440 1175×360×440 1065×360×535 1175×360×440
AKZ 9 SERIES
Equivalent to 0.4kW
Compressor(Totally enclosed DC swing type)
Equivalent to 0.75kW
Cross-fin coil type
Condenser
Motor
Propeller fan
Oil
pump
Equivalent to 1.1kW
Shell-end coil type
Evaporator
φ250、
54W
φ300、
54W
0.4kW×4P
Motor
Theoretical discharge rate L/min
Open pressure
Specifications and range of use
SynchroniTemperature zation
type
adjust
(Selectable)
Fixed
type
12/14.4
24/28.8
0.5
0.6
MPa
Room temperature or machine temperature *4
(Set to“Room temperature: Mode 3”by default)
Standard
Inlet oil temperature or outlet oil temperature
(Set to“Inlet oil temperature”by default)
Object to be controlled
Synchronization
range
−9.9∼+9.9 against the standard temperature
(Set at 0.0 by default)
K
Inlet oil temperature or outlet oil temperature
Object to be controlled
Range
5∼50
℃
Compressor revolutions by inverter + Opening of electric expansion valve
Refrigerant control
Refrigerant(New refrigerant: R410A)*5 Filling amount kg
Protection equipment
Room temperature
0.49
0.72
0.98
A set of overcurrent relay(motor for pump), reverse-phase protection equipment, restart prevention timer, low room-temperature protection thermostat, high
room-temperature protection thermostat, low oil-temperature protection thermostat, relief valve for pump, discharge tube temperature thermostat, condenser
temperature thermostat, refrigerant leak detector, and inverter protection equipment. High-pressure switch(−C type only), compressor protection thermostat
(−C type only), overheat prevention temperature thermostat(−H type only), boil-dry protection switch(−H type only), no-fuse breaker (−B type only)
5∼45
℃
5∼50
Inlet oil temperature ℃
Operating
Oil viscosity mm2/s
range
Product external Discharge side
pressure loss
Suction side
Usable oil
1.4∼200
(ISO VG2∼32)
0.5MPa or less
−30.7kPa or less
Lubricant, hydraulic oil of mineral oil(Not usable for hydraulic oil of ester phosphate, water, water-soluble liquid, drugs, food products, fuel, cutting liquid, grinding liquid, etc.)
Rc3/4
Oil inlet
Rc3/4
Connecting tube Oil outlet
Rc1 1/4
Rc3/4
Rc1 1/4
Noise value(Value measured at 1m high in front,
(A)
value equivalent as measured in anechoic chamber)dB
62
IP2X
kg
51
Molded-case circuit breaker(Rated current) A
− 10
Items to be prepared
by customer *8
Rc3/4
65
Ingress protection*6
Oil tank
(Capacity)
Rc1 1/4
Up down 14.7m/S2 ×2.5 hr
(7.5∼100Hz sweep / 5 min.)
Transport vibration performance*7
Mass
Rc3/4
Rc1/4
(Plugged)
Oil drain
L
78
68
87
−
−
15
56
83
−
Molded-case circuit
breaker(Rated current) A
73
−
20
64
92
−
− 10
91
−
81
100
−
− 10
−
20
−
10
(Required for types other than ーB type)
Note)*1. The cooling capacity represents the value at the standard point
(inlet oil temperature: 35℃, room temperature: 35℃, oil for use: ISO VG32)
.
The tolerance of the product is approx.±5%.
*2. Be sure to use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the unit.
The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us.
*3. There are three types of different voltage specifications depending on the power source: −046, −047 and −048 units. −047 and
−048 units deal with the different voltage by featuring a transformer.
The main circuit voltage is the transformer’
s secondary side voltage of 200 VAC, 50/60 Hz.
(−046 units have no transformer and therefore have the same external dimensions and mass as standard units. Their main circuit voltage is 220/230 VAC, 50/60 Hz.)
*4. The machine temperature synchronous thermistor optionally available is required for this function.
(Refer to Page 19 for details.)
*5. The MSDS
(Material Safety Data Sheet)of refrigerant R410A is attached to ーC type.
*6. Electric component box ingress protection: IP54 or equivalent (However, use piping conduits etc. rated at least IP54 at wiring ports.)
*7. The specifications for withstanding vibration during transport are those of a standard unit.
*8. The molded-case circuit breaker is not supplied with this product. Please prepare it by yourself.
*9. The yellow line on the tank oil level gauge shows the highest oil level and the red line the lowest oil level.
*10. The maximum power consumption/maximum current consumption of different voltage specifications are shown in the tables below.
■AKZ149
Supply power Power/current
380V
2.1A
0.92kW
400V
1.9A
415V
0.93kW
50/60Hz
440V
1.8A
0.92kW
460V
480V
0.93kW 1.7A
■AKZ569
Supply power Power/current
380V
4.0A
400V
3.8A
415V
3.6A
50/60Hz 2.22kW
440V
3.4A
460V
3.3A
480V
3.1A
5
■AKZ329
Supply power
380V
400V
415V
50/60Hz
440V
460V
480V
■AKZ439
Power/current
1.38kW 2.6A
1.44kW 2.5A
1.46kW 2.4A
1.38kW 2.3A
1.44kW 2.2A
1.46kW 2.1A
■AKZ909
Supply power Power/current
380V
7.1A
400V
6.8A
415V
6.5A
50/60Hz 4.28kW
440V
6.2A
460V
5.9A
480V
5.7A
Supply power
380V
400V
415V
50/60Hz
440V
460V
480V
Power/current
1.82kW 3.4A
1.89kW 3.3A
1.90kW 3.1A
1.82kW 3.0A
1.89kW 2.9A
1.90kW 2.7A
AKZ569
AKZ909
2.0
3.0
AKZ569
AKZ909
Oil Cooling Unit horsepower(HP)
Model name
Stan
dard
ーB ーC
ーT *9
*1
Circuit voltage
2
ー
Stan
dard
ーT *9
ーB ーC
ーH
Different voltage
specifications *3
3
ー
8.0/9.0
ー
kW
Supply power*2
Different voltage
specifications *3
5.0/5.6
Cooling capacity(50/60Hz) kW
Heater
ーH
3-Phase AC 200/200・220V 50/60Hz
Main circuit*3
ー
3-Phase AC 200/200・220V 50/60Hz
*3
*3
3-Phase AC 200/200・220V 50/60Hz
DC12/24V
Operating circuit
200V 50Hz
Max. power consumption
200V 60Hz
Max. consumption current
220V 60Hz
2.22kW/7.7A
2.50kW/8.4A
2.30kW/7.6A
2.57kW/8.1A
2.30kW/7.3A
3.00kW/8.9A
ー
Transformer capacity
4.25kW/13.6A
*10
*10
4.30kW/13.5A
4.28kW/13.0A
4.0kVA
ー
6.0kVA
Ivory white
Exterior color
Outside dimensions(H×W×D) mm 1110×470×560 1375×470×580 1410×470×560 1360×470×590 1220×560×680 1485×560×700 1520×560×680 1470×560×659
Equivalent to 2.2kW
Brazed plate type
Evaporator
Cross-fin coil type
Condenser
Motor
Propeller fan
Oil
pump
AKZ 9 SERIES
Equivalent to 1.5kW
Compressor(Totally enclosed DC swing type)
φ400、
100W
0.75kW×4P 0.7kW×4P
Motor
φ455、100W
0.75kW×4P
0.7kW×4P
Open pressure
0.6
MPa
Room temperature or machine temperature *4
(Set to“Room temperature: Mode 3”by default)
Standard
Inlet oil temperature or outlet oil temperature
(Set to“Inlet oil temperature”by default)
Object to be controlled
Synchronization
range
−9.9∼+9.9 against the standard temperature
(Set at 0.0 by default)
K
Inlet oil temperature or outlet oil temperature
Object to be controlled
Range
5∼50
℃
Compressor revolutions by inverter + Opening of electric expansion valve
Refrigerant control
Refrigerant(New refrigerant: R410A)*5 Filling amount kg
Protection equipment
Room temperature
1.02
1.48
A set of overcurrent relay(motor for pump), reverse-phase protection equipment, restart prevention timer, low room-temperature protection thermostat, high
room-temperature protection thermostat, low oil-temperature protection thermostat, relief valve for pump, discharge tube temperature thermostat, condenser
temperature thermostat, refrigerant leak detector, and inverter protection equipment. High-pressure switch(−C type only), compressor protection thermostat
(−C type only), overheat prevention temperature thermostat(−H type only), boil-dry protection switch(−H type only), no-fuse breaker (−B type only)
5∼45
℃
5∼50
Inlet oil temperature ℃
Operating
Oil viscosity mm2/s
range
Product external Discharge side
pressure loss
Suction side
Usable oil
1.4∼200
(ISO VG2∼32)
0.5MPa or less
−30.7kPa or less
Specifications and range of use
SynchroniTemperature zation
type
adjust
(Selectable)
Fixed
type
0.75kW×4P
30/36
Theoretical discharge rate L/min
Lubricant, hydraulic oil of mineral oil(Not usable for hydraulic oil of ester phosphate, water, water-soluble liquid, drugs, food products, fuel, cutting liquid, grinding liquid, etc.)
Rc1 1/4
Oil inlet
Rc1
Rc1 1/4
Rc1 1/4
65
67
Up down 14.7m/S2 ×2.5 hr
(7.5∼100Hz sweep / 5 min.)
Transport vibration performance*7
Ingress protection*6
IP2X
82
kg
Molded-case circuit breaker(Rated current) A
Oil tank
(Capacity)
Items to be prepared
by customer *8
Rc1 1/4
Rc1/4
(Plugged)
Oil drain
Noise value(Value measured at 1m high in front,
(A)
value equivalent as measured in anechoic chamber)dB
Mass
Rc1
Rc1 1/4
Connecting tube Oil outlet
L
Molded-case circuit
breaker(Rated current) A
−
15
−
100
115
145
−
50
97
−
132
122
20
−
−
15
(Required for types other than ーB type)
175
−
70
−
20
(Required for types other than ーB type)
Refer to Page 5 for explanatory notes.
Range of use
Note)
1. The mark ◎ shows the standard point.
2. Be sure to use the unit at the range
of use specified in .
︵℃︶
Room temperature
(The use outside the use range may cause unit failure.)
50
40
30
20
10
0
0
10
20
30
40
50
Inlet temperature
(℃)
6
AKZ
Cooling capacity characteristic chart
SERIES
1,800
AKZ149
Cooling capacity
(W)
1,600
Oil temperature =
Room temperature +10℃
1,400
Oil temperature =
Room temperature
1,200
Oil temperature =
Room temperature −10℃
1,000
800
600
400
200
AKZ 9 SERIES
0
5
10
15
20
25
30
35
40
45
Room temperature
(℃)
Oil temperature =
Room temperature +10℃
3,500
Cooling capacity
(W)
Cooling capacity characteristic chart
4,000
AKZ329
3,000
Oil temperature =
Room temperature
Oil temperature =
Room temperature −10℃
2,500
2,000
1,500
1,000
500
0
5
10
15
20
25
30
35
40
45
Room temperature
(℃)
6,000
AKZ439
Cooling capacity
(W)
5,000
Oil temperature =
Room temperature +10℃
Oil temperature =
Room temperature
Oil temperature =
Room temperature −10℃
4,000
3,000
2,000
1,000
0
5
10
15
20
25
30
Room temperature
(℃)
7
35
40
45
AKZ569
7,000
Oil temperature =
Room temperature +10℃
6,000
Cooling capacity
(W)
5,000
Oil temperature =
Room temperature
Oil temperature =
Room temperature −10℃
4,000
3,000
2,000
1,000
5
10
15
20
25
30
35
40
45
Room temperature
(℃)
Cooling capacity
(W)
10,000
Oil temperature =
Room temperature +10℃
8,000
Oil temperature =
Room temperature
6,000
Oil temperature =
Room temperature −10℃
4,000
2,000
0
5
10
15
20
25
30
35
40
Cooling capacity characteristic chart
12,000
AKZ909
AKZ 9 SERIES
0
45
Room temperature
(℃)
■Solid line :When operated at 60Hz ■Broken line :When operated at 50Hz
1. The mark“○”shows the standard point.
(Room temperature: 35℃ Inlet oil temperature : 35℃ Oil for use: ISO VG32)
2. The cooling capacity differs depending on conditions such as room temperature,
inlet oil temperature, oil dynamic viscosity and other factors.
8
9
AKZ
Outside dimension diagram
Note)Refer to Page 5
for more details.
The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the
positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not.
SERIES
With breaker
(453)
Standard specifications
⑰
⑱
⑲
⑮⑯
Part No.
Name
1
2
3
4
5
6
7
8
9
10
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
Name
11
12
13
14
15
16
17
18
19
20
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
(160)
⑭
90
②
⑳
(10)
Opposite
side
⑦
(674)
AKZ 9 SERIES
Opposite
side
⑧
⑩
⑪
(520)
⑫
Suction air
③
(13)
106
253
①
④
4-U slots
(for fixing bolts)
60
AKZ149-H
60
12
5
216
30
14
123
12
15
410
440
66
328
R6 (at all 4 locations)
12
With heater
Part No.
Name
1
2
3
4
5
6
7
8
9
10
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right)
Signal line inlet (Right / Left)
Eye plate
Air filter
⑱
Description
Part No.
Rc3/4
Rc1 1/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
Exhaust air
⑮⑯
⑨
⑥
⑤
(413)
⑬
38
(365)
Rear face
Name
(160)
⑳
Opposite
side
⑧
⑩
⑪
⑫
66
(13)
Suction air
(974)
(820)
650
(1000)
④
③
328
①
⑭
Opposite
side
⑰
406
②
79
111
190
314
300
Description
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Heater box
Heater drain
Rc1/4 Plugged
Air bleeder
Rc1/4 Plugged
⑦
⑧
90
⑲
11
12
13
14
15
16
17
18
19
20
21
22
23
123
30
(50)
15
30
300
360
4-φ12 holes
(for fixing bolts)
410
440
111
283
553
300
360
(505)
Outside dimension diagram
30
⑰
9
Description
(365)
⑦
⑧
⑨
(700)
650
φ28 Hole
φ22 Hole
φ25 Hole
Part No.
Exhaust air
38
⑥
⑤
Description
Rc3/4
Rc3/4
Rc1/4 Plugged
M6 plug
Rear face
(372)
⑬
Different voltages (without transformer)
Compliance with CE
513
AKZ149(-B,-C,-046)
Part No.
Name
1
2
3
4
5
6
7
8
9
10
11
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
Room temperature thermistor
⑰
Description
Rc3/4
Rc3/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
⑱
⑲
Rear face
⑭
②
⑳
(10)
650
Opposite
side
⑦
③
(834)
(680)
Suction air
125
174
160
Red line 11L
123
30
105
4-φ12 holes
(for fixing bolts)
300
410
20
66
535
110
360
AKZ149-047,-048
Different voltages (With transformer)
Part No.
(500)
1
2
3
4
5
6
7
8
9
10
⑰
Name
Description
Rc3/4
Oil inlet
Oil outlet
Rc3/4
Oil drain
Rc1/4 Plugged
Oil pan drain
M6 plug
Control panel
Electric component box lid
Power supply inlet φ28 Hole
φ22 Hole
Signal line inlet
Hanger
Air filter
⑱
(420)
⑲
⑮⑯
Part No.
Name
11
12
13
14
15
16
17
18
19
20
21
22
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Transformer
Transformer box
Description
Outside dimension diagram
①
Yellow line 15L
AKZ 9 SERIES
(860)
15L
Rc3/8 Plugged
KLA-50A
HY-06T
(160)
⑫
④
Description
(365)
Opposite
side
⑧
⑩
⑪
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Oil tank
Tank drain
Oil level gauge*
Oil hole-cum-air bleeder
673
⑨
⑥
⑤
⑬
38
⑦
⑧
90
(23)
⑮⑯
Name
12
13
14
15
16
17
18
19
20
21
22
23
24
*The yellow line on the oil level gauge shows
the highest oil level and the red line the lowest oil level.
(Keep the oil level between the yellow and red lines during use.)
Exhaust air
(372)
Part No.
413
With tank
540
(635)
AKZ149-T
Exhaust air
Rear face
(365)
⑬
⑥
⑤
⑭
*1
⑩
⑪
②
⑳
(10)
⑫
650
③
Suction air
60
①
813
④
(13)
38
123
30
30
300
360
4-φ12 holes
(for fixing bolts)
(50)
15
410
⑰
(13)
440
(13)
406
⑧
⑦
(270)
270
314
300
553
⑨
66
328
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
10
9
AKZ
Outside dimension diagram
Note)Refer to Page 5
for more details.
The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the
positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not.
SERIES
With breaker
⑰
⑱
⑮⑯ Rear face
(372)
Name
1
2
3
4
5
6
7
8
9
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
(645)
②
③
Suction air
①
106
15
300
12
AKZ329-H
60
5
216
60
R6 (at all 4 locations)
12
With heater
⑰
⑱
⑨
⑥
⑤
⑬
Name
1
2
3
4
5
6
7
8
9
10
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right)
Signal line inlet (Right / Left)
Eye plate
Air filter
Description
Rc3/4
Rc1 1/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
Exhaust air
⑮⑯ Rear face
(413)
Part No.
38
(365)
Part No.
11
12
13
14
15
16
17
18
19
20
21
22
23
Name
(160)
⑦
⑧
⑩
⑪
⑳
Opposite
side
⑧
775
⑫
(1099)
(945)
(1125)
66
④
Suction air
(13)
③
328
①
⑭
Opposite
side
⑰
406
②
79
111
190
314
300
Description
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Heater box
Heater drain
Rc1/4 Plugged
Air bleeder
Rc1/4 Plugged
90
⑲
66
328
30
123
12
410
440
4-U slots
(for fixing bolts)
360
14
Outside dimension diagram
30
123
30
(50)
300
360
30
4-φ12 holes
(for fixing bolts)
15
410
440
111
283
553
AKZ 9 SERIES
⑫
④
11
Description
(10)
Opposite
side
⑦
(825)
775
Air filter
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
⑳
(13)
(505)
Name
10
11
12
13
14
15
16
17
18
19
20
⑭
Opposite
side
⑧
⑩
⑪
Part No.
(160)
90
⑥
⑤
φ28 Hole
φ22 Hole
φ25 Hole
(365)
⑦
⑧
⑨
Description
Rc3/4
Rc3/4
Rc1/4 Plugged
M6 plug
Exhaust air
38
⑬
Part No.
253
⑲
Different voltages (without transformer)
Compliance with CE
648
(453)
Standard specifications
(799)
AKZ329(-B,-C,-046)
With tank
540
(635)
AKZ329-T
⑰
⑱
Part No.
Name
1
2
3
4
5
6
7
8
9
10
11
12
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
Room temperature thermistor
Unit faceplate
Description
Rc3/4
Rc3/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
Rear face
⑬
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Oil tank
Tank drain
Oil level gauge*
Oil hole-cum-air bleeder
Description
20L
Rc3/8 Plugged
KLA-80A
HY-06T
(365)
(160)
⑭
②
⑳
(10)
Opposite
side
⑦
③
838
(835)
(989)
775
⑫
Suction air
443
①
155
Red line 11L
123
30
4-φ12 holes
(for fixing bolts)
300
105
410
AKZ329-047,-048
20
66
535
360
Different voltages (With transformer)
Part No.
(500)
1
2
3
4
5
6
7
8
9
10
⑰
⑱
110
Name
Description
Rc3/4
Oil inlet
Oil outlet
Rc3/4
Oil drain
Rc1/4 Plugged
Oil pan drain
M6 plug
Control panel
Electric component box lid
Power supply inlet φ28 Hole
φ22 Hole
Signal line inlet
Hanger
Air filter
Exhaust air
⑲
(420)
⑬
⑮⑯
Rear face
Part No.
Name
11
12
13
14
15
16
17
18
19
20
21
22
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Transformer
Transformer box
Description
(365)
⑭
⑥
⑤
⑩
⑪
②
⑳
*1
(10)
775
⑫
Suction air
④
38
①
⑨
270
123
30
30
300
360
4-φ12 holes
(for fixing bolts)
⑧
⑦
15
410
⑰
(13)
440
(13)
406
314
300
553
60
(13)
948
③
(270)
204
190
Yellow line 20L
Outside dimension diagram
④
AKZ 9 SERIES
Opposite
side
⑧
⑩
⑪
(1015)
38
⑦
⑧
⑨
⑥
⑤
90
(23)
Exhaust air
⑮⑯
Name
13
14
15
16
17
18
19
20
21
22
23
24
*The yellow line on the oil level gauge shows
the highest oil level and the red line the lowest oil level.
(Keep the oil level between the yellow and red lines during use.)
⑲
(372)
Part No.
66
328
(50)
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
12
9
AKZ
Outside dimension diagram
Note)Refer to Page 5
for more details.
The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the
positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not.
SERIES
With breaker
⑰
⑱
⑲
⑮⑯ Rear face
(372)
Part No.
Name
1
2
3
4
5
6
7
8
9
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Description
Rc3/4
Rc3/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
(365)
Description
90
②
(10)
(899)
AKZ 9 SERIES
Opposite
side
⑦
(745)
Air filter
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
⑳
⑫
(925)
875
Name
10
11
12
13
14
15
16
17
18
19
20
⑭
Opposite
side
⑧
⑩
⑪
Part No.
(160)
⑦
⑧
⑨
⑥
⑤
Different voltages (without transformer)
Exhaust air
38
⑬
Compliance with CE
③
Suction air
(13)
①
106
300
360
AKZ439-H
15
216
60
12
14
123
60
12
4-U slots
(for fixing bolts)
5
30
30
(505)
Outside dimension diagram
④
708
(453)
Standard specifications
253
AKZ439(-B,-C,-046)
12
⑰
⑱
⑨
⑥
⑤
⑬
Part No.
Name
1
2
3
4
5
6
7
8
9
10
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right)
Signal line inlet (Right / Left)
Eye plate
Air filter
Description
Rc3/4
Rc1 1/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
Exhaust air
38
(365)
(160)
⑦
⑧
Part No.
11
12
13
14
15
16
17
18
19
20
21
22
23
Name
Description
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Heater box
Heater drain
Rc1/4 Plugged
Air bleeder
Rc1/4 Plugged
⑳
90
⑲
⑮⑯ Rear face
66
328
R6 (at all 4 locations)
With heater
(413)
410
440
⑩
⑪
Opposite
side
⑧
(1199)
(1225)
875
⑫
(1045)
Suction air
66
(13)
③
328
①
④
406
79
111
190
314
300
②
123
30
(50)
13
30
300
360
4-φ12 holes
(for fixing bolts)
15
410
440
111
283
553
⑭
Opposite
side
⑰
With tank
540
(635)
AKZ439-T
⑰
⑱
⑲
(23)
⑮⑯
Part No.
Name
1
2
3
4
5
6
7
8
9
10
11
12
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
Room temperature thermistor
Unit faceplate
Rear face
38
⑦
⑧
Name
13
14
15
16
17
18
19
20
21
22
23
24
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Oil tank
Tank drain
Oil level gauge*
Oil hole-cum-air bleeder
Description
20L
Rc3/8 Plugged
KLA-80A
HY-06T
*The yellow line on the oil level gauge shows
the highest oil level and the red line the lowest oil level.
(Keep the oil level between the yellow and red lines during use.)
⑭
(160)
⑳
②
(10)
Opposite
side
⑦
(1089)
Suction air
③
898
(935)
875
(1115)
⑫
443
①
30
155
Red line 11L
123
AKZ439-047,-048
105
4-φ12 holes
(for fixing bolts)
300
360
Different voltages (With transformer)
410
535
(500)
⑱
(420)
⑲
⑮⑯
Rear face
66
110
Part No.
1
2
3
4
5
6
7
8
9
10
⑰
20
Name
Description
Rc3/4
Oil inlet
Oil outlet
Rc3/4
Oil drain
Rc1/4 Plugged
Oil pan drain
M6 plug
Control panel
Electric component box lid
Power supply inlet φ28 Hole
φ22 Hole
Signal line inlet
Hanger
Air filter
Exhaust air
Part No.
Name
11
12
13
14
15
16
17
18
19
20
21
22
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Caution plate
Transformer
Transformer box
Description
(365)
⑬
⑭
⑥
⑤
⑳
*1
⑩
⑪
②
(10)
875
⑫
Suction air
④
38
①
⑨
270
⑧
⑦
406
314
300
553
60
(13)
1008
③
(270)
190
204
Yellow line 20L
Outside dimension diagram
④
AKZ 9 SERIES
Opposite
side
⑧
⑩
⑪
Part No.
(365)
90
⑨
⑥
⑤
φ28 Hole
φ22 Hole
φ25 Hole
Exhaust air
(372)
⑬
Description
Rc3/4
Rc3/4
Rc1/4 Plugged
M6 plug
⑰
123
30
30
300
360
4-φ12 holes
(for fixing bolts)
15
410
(13)
440
66
(13)
328
(50)
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
14
9
AKZ
Outside dimension diagram
Note)Refer to Page 6
for more details.
The positions of the fixing bolt holes and the oil outlet/inlet ports are compatible
with the AKZ 8 series, but the positions of the power supply/signal cable inlet ports are not.
SERIES
Standard specifications
With breaker
Name
1
2
3
4
5
6
7
8
9
10
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
⑮⑯
(480)
⑬⑳
Inside
face
Rear face
Description
Rc1 1/4
Rc1 1/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
Description
⑭
③
①
597
Suction air
875
⑫
(1135)
390
470
(517)
AKZ569-H
60
327
306
60
15
530
560
(13)
75
110
240
12
(at all 4 locations)
22
With heater
Part No.
1
2
3
4
5
6
7
8
9
10
⑰
⑱
⑲
(480)
⑬⑳
Inside
face
⑮⑯
Description
⑦
⑧
38
③
110
Suction air
①
513
(13)
110 94
(316)
300
Description
15
4-φ12 holes
(for fixing bolts)
897
(1370)
(1435)
(1460)
(1410)
1110
Name
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
Heater box
Heater drain
Rc1/4 Plugged
Air bleeder
Rc1/4 Plugged
Opposite
side
⑧
④
327
390
470
11
12
13
14
15
16
17
18
19
20
21
22
23
(425)
(191)
⑫
40
Part No.
Exhaust air
Rear face
⑨
⑥
⑤
⑩
⑪
Name
Rc1 1/4
Oil inlet
Oil outlet
Rc1 1/4
Oil drain
Rc1/4 Plugged
Oil pan drain
M6 plug
Control panel
Electric component box lid
Power supply inlet φ28 Hole
φ22 Hole
Signal line inlet
φ25 Hole
Eye plate
Air filter
530
560
132
22
5
30
(16)
4-U slots
(For fixing bolts)
500
R6
Outside dimension diagram
40
30
213
AKZ 9 SERIES
Opposite
side
⑦
(980)
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
②
(13)
Opposite
side
⑧
(1160)
1110
Name
11
12
13
14
15
16
17
18
19
20
Exhaust air
⑦
⑧
④
15
Part No.
(425)
(191)
38
⑨
⑥
⑤
⑩
⑪
90
⑰
⑱
⑲
Different voltages (without transformer)
Compliance with CE
Part No.
(517)
AKZ569(-B,-C,-046)
102
240
331
②⑭
(750)
AKZ569-T
With tank
⑰
⑱
⑲
88
⑮⑯
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
Room temperature thermistor
Description
⑨
⑥
⑤
⑩
⑪
(425)
(191)
90
⑭
Opposite
side
⑦
③
862
①
230
(281)
25
4-φ12 holes
(for fixing bolts)
AKZ569-047,-048
530
580
Different voltages (With transformer)
(642)
1
2
3
4
5
6
7
8
9
10
⑰
⑱
(530)
⑬⑳
⑮⑯
Name
Description
Part No.
Name
11
12
13
14
15
16
17
18
19
20
21
22
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
Transformer
Transformer box
Rc1 1/4
Oil inlet
Oil outlet
Rc1 1/4
Oil drain
Rc1/4 Plugged
Oil pan drain
M6 plug
Control panel
Electric component box lid
Power supply inlet φ28 Hole
φ22 Hole
Signal line inlet
Hanger
Air filter
Description
Exhaust air
Rear face
38
Inside face
⑥
⑤
⑩
⑪
110
360
395
Part No.
(425)
⑭
90
(13)
*1
②
⑫
1110
③
(40)
500
(13)
390
470
4-φ12 holes
(for fixing bolts)
(40)
(50)
⑰
60
30
(13)
463
⑨
⑦
⑧
100
266
30
250
38
30
847
④
327
①
1125
(1230)
Suction air
(202)
265
1140
(1400)
(1245)
Suction air
Outside dimension diagram
327
390
470
50L
Rc3/8 Plugged
KLA-80A
HY-06T
②
(13)
Opposite
side
⑧
1110
(1425)
(1375)
Description
AKZ 9 SERIES
Red line 37L
⑲
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
Oil tank
Tank drain
Oil level gauge*
Oil hole-cum-air bleeder
*The yellow line on the oil level gauge shows
the highest oil level and the red line the lowest oil level.
(Keep the oil level between the yellow and red lines during use.)
⑦
⑧
④
40
Name
12
13
14
15
16
17
18
19
20
21
22
23
24
φ28 Hole
φ22 Hole
φ25 Hole
⑫
Yellow line 50L
Part No.
Rc1
Rc1 1/4
Rc1/4 Plugged
M6 plug
Exhaust air
38
Inside face
Name
1
2
3
4
5
6
7
8
9
10
11
Rear face
(480)
⑬⑳
Part No.
75
110
530
590
(13)
240
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
16
9
AKZ
Outside dimension diagram
Note)Refer to Page 6
for more details.
The positions of the fixing bolt holes and the oil outlet/inlet ports are compatible
with the AKZ 8 series, but the positions of the power supply/signal cable inlet ports are not.
SERIES
Standard specifications
With breaker
(635)
⑰
⑱
⑲
⑮⑯
(570)
Inside
face
⑨
⑥
⑤
⑪
⑩
Name
1
2
3
4
5
6
7
8
9
10
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
⑦
⑧
φ28 Hole
φ22 Hole
φ25 Hole
Description
⑭
②
(1245)
①
790
Suction air
③
512
(1130)
30
620
22.5
635
680
(13)
88
123
257
12
(at all 4 locations)
22
60
With heater
⑰
⑱
⑲
(570)
⑮⑯
⑬⑳
Name
1
2
3
4
5
6
7
8
9
10
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
Description
Part No.
11
12
13
14
15
16
17
18
19
20
21
22
23
Rc1 1/4
Rc1 1/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
Exhaust air
Rear face
38
Inside
face
Part No.
⑦
⑧
⑨
⑥
⑤
Name
Description
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
Heater box
Heater drain
Rc1/4 Plugged
Air bleeder
Rc1/4 Plugged
(545)
(311)
Opposite
side
⑧
⑪
⑩
②
⑫
①
Suction air
30
620
22.5
635
680
400
480
560
4-φ12 holes
(for fixing bolts)
132
110 94
(316)
300
40
(13)
513
(1545)
(1480)
(1570)
(1520)
1220
③
812
(635)
AKZ909-H
5
30
(16)
60
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
R6
Outside dimension diagram
4-U slots
(For fixing bolts)
400
396
22
Name
11
12
13
14
15
16
17
18
19
20
(13)
Opposite
side
⑦
(1270)
1220
AKZ 9 SERIES
480
560
Part No.
(545)
(311)
⑫
40
Description
Rc1 1/4
Rc1 1/4
Rc1/4 Plugged
M6 plug
Opposite
side
⑧
④
17
Part No.
Different voltages (without transformer)
Exhaust air
38
50
⑬⑳
Rear face
Compliance with CE
213
AKZ909(-B,-C,-046)
190
257
419
②⑭
(870)
AKZ909-T
With tank
88
⑰
⑱
⑲
⑮⑯
38
⑨
⑥
⑤
⑦
⑧
50
Inside face
Name
1
2
3
4
5
6
7
8
9
10
11
Oil inlet
Oil outlet
Oil drain
Oil pan drain
Control panel
Electric component box lid
Power supply inlet (Right / Left)
Signal line inlet (Right / Left)
Eye plate
Air filter
Room temperature thermistor
Description
Part No.
Name
12
13
14
15
16
17
18
19
20
21
22
23
24
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
Oil tank
Tank drain
Oil level gauge*
Oil hole-cum-air bleeder
Rc1
Rc1 1/4
Rc1/4 Plugged
M6 plug
φ28 Hole
φ22 Hole
φ25 Hole
Exhaust air
Rear face
(570)
⑬⑳
Part No.
Description
*The yellow line on the oil level gauge shows
the highest oil level and the red line the lowest oil level.
(Keep the oil level between the yellow and red lines during use.)
(545)
(311)
Opposite
side
⑧
Opposite
side
⑦
⑭
②
(13)
AKZ 9 SERIES
⑪
⑩
70L
Rc3/8 Plugged
KLA-80A
HY-06T
⑫
(1510)
Suction air
1055
(1395)
(1535)
(1485)
1220
③
230
(281)
4-φ12 holes
(for fixing bolts)
400
480
560
AKZ909-047,-048
650
700
25
Different voltages (With transformer)
Part No.
(747)
(620)
⑬⑳
Inside face
⑮⑯
Description
Part No.
Name
11
12
13
14
15
16
17
18
19
20
21
22
Room temperature thermistor
Unit faceplate
Design faceplate
Instruction faceplate
Overall caution plate
Electric schematic diagram faceplate
Battery charge mark faceplate
Cutting injury caution plate
High temperature caution plate
Model name nameplate
Transformer
Transformer box
Description
Exhaust air
Rear face
⑥
⑤
Name
Rc1 1/4
Oil inlet
Oil outlet
Rc1 1/4
Oil drain
Rc1/4 Plugged
Oil pan drain
M6 plug
Control panel
Electric component box lid
Power supply inlet φ28 Hole
φ22 Hole
Signal line inlet
Hanger
Air filter
1
2
3
4
5
6
7
8
9
10
⑰
⑱
⑲
110
437
472
38
(545)
⑭
50
*1
⑩
⑪
(13)
⑫
②
①
38
620
(13)
⑦
⑧
⑨
100
(250)
(266)
30
(40)
30
400
480
560
4-φ12 holes
(for fixing bolts)
(40)
(50)
60
30
(13)
⑰
635
695
(13)
463
④
762
1040
(1380)
1220
③
Suction air
(202)
265
Red line 51L
40
①
Outside dimension diagram
Yellow line 70L
777
④
88
123
257
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
18
Optional
part
Thermistor(Compatible with all types of Oil Cooling Unit 9 series)
■Thermistor models and applications
When this optional part is installed in the oil piping of the main machine,
the thermistor detects the temperature to allow the control of oil temperature.
Model
Machine temperature synchronous thermistor
AKZ 9-OP-K5
Length of
lead wire
L(m)
Application Applicable
(To be installed) model
by you
Shape
5m
AKZ 9-OP-K15 15m
Lead wire
5m
80
φ1.1
(φ4.5)
φ8
25
Lead wire
(φ4.5)
R1/8
AKZ 9-OP-Y10 10m
80
27.5
For machine
temperature
synchronous
control
Attached to the
surface of main
machine body
( )
XHP-3
(Blue)
SXH-001T-0.6
5m
For machine
temperature
synchronous
control
Implanted in
the main
machine body
( )
Plug-in terminal
AKZ 9-OP-A10 10m
AKZ 9-OP-Y5
φ1.1
R1/8
AKZ 9-OP-A5
80
27.5
(φ4.5)
AKZ 9-OP-K10 10m
(φ5)
Plug-in terminal
(φ5)
Thermistor
Thermistor for
oil temperature control
Optional part
Name
AKZ 9
Series
For return oil
temperature
control
Installed in oil
tube of the
main machine
( )
Lead wire
Thermistor characteristics: Resistance value … R25(Resistance value at 25℃)= 20kΩ, Tolerance: ±3%
■Instruction for installation and connection
AKZ 9-OP-K
Main
machine
body
(
)
Rc 1/8
(To be machined on the main machine side)
Drill holeφ8, 20 or more in depth
Connect to Oil Cooling Unit x 2M
Terminal box Nos. 30 and 31.
Fill the hollow portion with silicon grease.
Recommended grease: Heat dissipating grease No. KS609
made by Shin-Etsu Chemical Co., Ltd.
AKZ 9-OP-A
(Main machine body)
Please prepare the band and mounting screws yourself.
Connect to Oil Cooling Unit x 2M
Terminal box Nos. 30 and 31.
Keep this part in close contact with the
main body and cover the part with putty.
AKZ 9-OP-Y
Rc 1/8
Screw seat
Oil tube
Connect to Oil Cooling Unit control board connector CN11.
Replace this part with the oil outlet thermistor and operate
in the outlet oil temperature control mode Nos. 1, 5 and 6.
19
9
AKZ
SERIES
■Installation positions of additional oil temperature control thermistor
(machine body or others)
Machine temperature
synchronous thermistor
Installation position
(No. 30/31 pin)
Thermistor for
oil temperature control
Installation position
(CN11)
Control board
Optional part
Expansion board for main machine communication
Communication
method
Model
Installation position
Applicable model
Specification
sheet No.
Serial communication
only
AKZ9-OP-CS
Installation plate inside
electric component box
AKZ149、AKZ329、AKZ439、AKZ569、AKZ909
PSP04664
Note)1. Refer to the specifications sheet for the communication procedure and specifications.
■Installation position for AKZ9-OP-CS(serial communication only)
D-SUB 9 pin connector
Overcurrent circuit breaker
(Not featured on some types)
AKZ9-OP-CS board
Supplied
lead wire
AKZ9-OP-CS board
Expansion board for main machine communication
The following functions are enabled by mounting this option board on the Oil Cooling Unit and
connecting it to the main machine:
1. The operation mode and the operation setting can be changed from the main machine side.
2. The alarm code and temperature data (machine temperature, room temperature, inlet oil temperature,
outlet oil temperature, inlet and outlet differential temperature, inverter frequency) of Oil Cooling Unit
can be read from the main machine side.
Control board
Connect to CN12
on the control board
・Dimensions of communication board (W×H): 40×50
・The communication board is secured at four positions by locking support.
20
Supporting
information
Part names, functions and operation of control panel
1
5
2
11
3
6
4
7
NO.
8
9
10
Item
Description
Supporting information
Part names, functions and operation of control panel
1
Power lamp (Green)
2
Error warning lamp (Red)
3
Timer mode lamp (Red)
4
Operation mode display
5
Operation mode /
Data No. display
Displays the current operation mode (Normal mode, Operation setting mode) or
data number of the data currently displayed on the data display part.
6
Data display
Displays various data. The data displayed differs depending on the operation mode and data number.
7
[SELECT]key
Selects the operation mode.
8
[DOWN]key
Decrements the value of the operation mode, data number and data by 1.
When held for two seconds or longer, decrements the values by 10.
9
[UP]key
Increments the value of the operation mode, data number and data by 1.
When held for two seconds or longer, increments the values by 10.
10
[ENT](Determine) key
Determines the operation mode, data number, and data to be changed.
11
Warning lamp (Green)
The lamp is turned on while power is supplied.
When an error occurs
Level 1 alarm: The lamp keeps blinking
Level 2 alarm: The lamp is turned on
The lamp keeps blinking while the unit is at a stop in the timer mode.
Displays the mode of the control panel
When a warning occurs
NORMAL: Normal mode
SETTING: Operation setting mode
MONITOR: Monitor mode
TIMER SET:Timer setting mode
Level 1 warning: The lamp keeps blinking.
Level 2 warning: The lamp is turned on.
■Operation for change to each mode
A mode can be changed by operating the
key in general.
To enter a special mode, hold down a number of keys in combination for more than 5 seconds.
Hold down for more than 5 seconds.
Turn on the power
Operation
lock mode
Normal
mode
Operation
setting mode
Hold down for more than 5 seconds.
Timer
setting mode
Auto tuning
mode
Hold down for more than 5 seconds.
Monitor
mode
Parameter
setting mode
■ The default setting is“Operation lock mode”
.
To start operation, perform the unlocking operation as shown above.
CAUTION
21
■ The default setting for operation on the standard unit is:
Operation mode: 3 (Inlet oil temperature control, room temperature synchronization control)
Differential temperature: 0.0 (K)
9
AKZ
SERIES
Supporting
information
Operation mode and setting method
AKZ 9 Series
Mode No.
Mode name
Description
Setting temperature range
Mode 0
Inlet oil temperature,
fixed temperature control
Keep the inlet oil temperature at the setting temperature
within the range specified in the right column.
Necessary optional part
5∼50℃
Mode 1
Outlet oil temperature or
return oil temperature control
Fixed temperature control
Keep the outlet oil temperature or return
oil temperature at the setting temperature within
the range specified in the right column.
5∼50℃
Mode 3
Inlet oil temperature, room
temperature synchronous control
Keep the inlet oil temperature at the setting temperature
within the range specified in the right column.
Between Room temperature
-9.9℃ and Room temperature + 9.9℃
Mode 4
Inlet oil temperature, machine
temperature synchronous control
Keep the inlet oil temperature at the setting temperature
within the range specified in the right column.
Between Machine temperature
-9.9℃ and Machine temperature+ 9.9℃
Machine temperature
synchronous thermistor
Mode 5
Outlet oil temperature or return oil
temperature control, room
temperature synchronous control
Keep the outlet oil temperature or return
oil temperature at the setting temperature within
the range specified in the right column.
Between Room temperature
-9.9℃ and Room temperature + 9.9℃
Mode 6
Outlet oil temperature or
return oil temperature control
Machine temperature
synchronous control
Keep the outlet oil temperature or return
oil temperature at the setting temperature within
the range specified in the right column.
Between Machine temperature
-9.9℃ and Machine temperature + 9.9℃
Oil temperature control
thermistor (When return oil
temperature is controlled)
Oil temperature control
thermistor (When return oil
temperature is controlled)
Machine temperature
synchronous thermistor
Oil temperature control
thermistor (When return oil
temperature is controlled)
Note) 1. Modes 2, 7, and 8 cannot be used on this series. Note) 2. Refer to Page 19 for details of necessary optional parts.
■Setting procedure: AKZ
Default setting: Set to“Mode: 3”and temperature to“0.0”. When you use your unit at a setting other than
the default setting, change the setting following the procedure shown below.
Hold down the
key and
key simultaneously for more than 5 seconds.
2 Select the“Setting”mode and press the
key once.
Change the mode
Blinking
3 Press the
or
Press the
[ENT] key
to switch
between
“Mode”
and
“Data”.
The number of the“Mode”
is increased by one.
key for mode setting.
4 Determine the value by pressing the
The“Setting temperature”
is reduced by 0.1.
5 Press the
key.
7 To return to the“Normal”mode, press the
or
The“Setting temperature”
is increased by 0.1.
key for temperature setting.
6 Determine the value by pressing the
key.
key three times.
Operation mode and setting method
The number of the“Mode”
is decreased by one.
Change the setting temperature
Blinking
Supporting information
1 Power ON --- Release the operation lock mode before starting operation for the first time.
Points checked in the monitor mode
The following points can be checked in the monitor mode.
Monitor No.
Description
Note
Monitor No.
Description
Note
0
Machine body temperature【Th1】
*1
5
△T
(Th4∼Th2)
*1
1
Outlet oil temperature or return oil temperature【Th2】
*1
6
Cooling capacity control command value(%)
−
2
Room temperature【Th3】
*1
7
Compressor inverter rotational speed(rps)
−
3
Inlet oil temperature【Th4】
*1
8
Power consumption(kW)
*3
4
Reserved【Th5】
*1
9
Extended DIN(hundreds digit), DOUT(tens digit)status
*2
*1. If the thermistor is not connected or has a broken wire, −99.9 is displayed.
*2. With the default setting, 0 is displayed. Note that display is enabled when parameter n020 is“1”or the optional communication expansion board is installed.
*3. This is the value obtained by rough calculation under the following conditions (the error is around 20%): power supply voltage of 200 V, pump discharge pressure of 0.2 MPa (VG32: oil temperature 25℃). Contact us separately about pumpless units.
22
10
Remote
control
11
13
Optional
protection
equipment
12
31
60
61
62
63
5
4
L1
L2
L3
A3P
66
S160
65
∼
-
Th-8
Th-7
Th-6
X2M
67
S9
SA
X519
X500
2
6
S130
Option
Th-9
Th-2
S5P
−H type only
Option
Option
Th-1
9 10 11 12 13 30 31
X4M
M
3∼
M1P
S0
MR30Y
For external
communications (serial)
CN12
S10 For shipping adjustments
Analog monitor
-
+
ACDC
Alarm output
S179
+12V
DCL2
-
+
3
S171
Short-circuit line
S172
Shortcircuit line
Expansion board for main
machine communication
Thermistor for oil
temperature control
Machine temperature
synchronous thermistor
K1S
S4T
AKZ9-OP-CS
A5P
Th-9
Th-1
Part symbol
−H type only
Short-circuit line
Magnetic
contact coil K2M
23
IC600
Th300
−H type only
X4M
24
95
96
AKZ9-OP-K5
AKZ9-OP-K10
AKZ9-OP-K15
AKZ9-OP-A5
AKZ9-OP-A10
AKZ9-OP-Y5
AKZ9-OP-Y10
Model
θS2T S3PH
CE type only CE type only
S170
+15VE
S185
S184
S183
S182
CN2
+12V
LED300
-
C550 C551 +
FU550 +
∼
3.15A 250V
- -
Power supply circuit
DCL
CN6 Inverter CPU normal
-
DCL1
Protection equipment
input circuit
S140
2
CN110
CN650
∼
[Optional part]
Name
-047, 048 only
60 61 62 63 64 65 66 67
∼
FU650
3.15A 250V
CN103
R
S
T
A2P
Communication
60 61 62 63 64 65 66 67
Board communicating Control CPU normal
X2M
9 10 11 12 13 30 31
CN10 CN11
Operational error
prevention switch
High-accuracy analog input
SW0
Th-3
T1 U1
T2 V1
T3 W1
K1S
Black (red)
Black (white)
Black
L1
L2
L3
5
For external communication S150 S151
(parallel)
X520
Relay control
X510
Black
Black
Black
LED_A
LED140
R
S
T
X530
Relay control
S60
Photocoupler
Surge
absorber
Power supply circuit
FU511
FU512
FU513
6.3A 250V
SA
Expansion user I/O
S90
S80
S200
A1P
X501
Th-4
24
64
Y1E
M
Black
Red
Option
A5P
A4P
T1R
t°Black
Red
E1H t° t°
−H type only F1UT F2UT
U2 V2 W2
K2M
R S T X3M
Black (red)
Black (white)
Black
For −B units only
Black (red)
Black (white)
Black
For connection Normal Pump operation
Warning output
of machine
Error / Power failure
synchronization
thermistor
OFF : Level 1
Alarm, level output
ON : Level 2
30
X1M
Black (red)
Black (white)
Black
For −047 and −048 types
MCCB
Note) 1. If a thermistor for temperature control (Th-9) is used, the existing Th-2 at CN11 is to be replaced.
2. Refer to the electric schematic diagram of ach type for details.
9
Warning and operation signal
[Power supply]
Model
Supply power
Standard , 3∼200/200・220V
−C, −B,
50/60Hz
−T, −H
3∼220・230V
-046
50/60Hz
3∼380・400・415V
-047
50/60Hz
3∼440・460・480V
-048
50/60Hz
L1
L2
L3
L1
L2
L3
MCCB
Tr
Input
Output
0V
MR52Pa
X3M
MR30X
L1
L2
L3
Electric schematic diagram
Black
Black
Black
Supporting information
23
MR30W
Y2E
M
Th-Fin
N=4
S172
CE type only
θS2T
M3F
S5P
S4T
K2M
X3M,X4M
−047,048
MCCB
(Different voltage Tr
specifications,
with transformer) X3M,X4M
−H
(With heater)
S2T
−C
(CE compliance type)
S3PH
F1UT,F2UT
E1H
−B (With breaker) MCCB
Circuit breaker
Compressor protection
thermostat
High-pressure switch
Thermal fuse
Heater
Magnetic contact
Magnetic contact coil
Overheat prevention
temperature switch
Boil-dry protection
pressure switch
Terminal block
Circuit breaker
Transformer
Terminal block
Additional part symbol
Control board
Inverter board
Noise filter board
Display board
Condenser
Connector
Ferrite core
Reactor
Fuse
Overcurrent relay
Motor (Pump)
Motor (Compressor)
Motor (Fan)
Machine temperature
Th-1
synchronous thermistor (option)
Th-2
Outlet oil temperature thermistor
Th-3
Air (room temperature) thermistor
Th-4
Inlet oil temperature thermistor
Th-6
Discharge gas temperature thermistor
Th-7
Condensation temperature thermistor
Th-8
EV valve outlet temperature thermistor
Th-9
Oil temperature thermistor (option)
Fin temperature thermistor
Th-Fin
Th300
Box temperature thermistor
Transformer
T1R
X1M,X2M Terminal block
Y1E,Y2E Electronic expansion valve
A1P
A2P
A3P
A4P
C
CN,S,X
COR
DCL
FU
K1S
M1P
M2C
M3F
[Standard, −046
(different voltage specifications, without transformer)]
M2C
Yellow
Red
White
M
Black
Brown
DC
Orange
Blue
Red
Yellow M
3∼
Blue
[Semi-standard types]
Type name
6
CN7
CN20
CN18
U
V
W
GND
Vcc
Hu
Hv
CN600 COR
CN15
Supporting
information
Electric schematic diagram(Typical diagram)
9
AKZ
SERIES
Electric wiring connection instruction diagram
1 Power supply capacity … Refer to the max. power consumption and max. consumption
current of the specification sheet of each type.
2 Connection to power supply terminal block(X1M, Tr)
(1)
(2)
(1)In the case of the standard type and semi-standard type
(−C,
−H,
−T,
−046)
, connect the line to X1M.
(2)In the case of“with breaker”
(−B)specifications,
connect to the circuit breaker.
(3)In the case of the semi-standard type(with transformer:−047,
−048),
connect the line to the terminal block supplied with the transformer.
(3)
1.Screw terminal and wiring diameter
L1
L2
L3
L1
L2
L3
U
V
W
Wiring diameter
Terminal Screw
block terminal JIS cable IEC cable UL cable
Series
AKZ 149,329,439,569
AKZ 909
X1M
M4
Breaker
M5
X1M
M5
Breaker
M5
2.0mm2
or more
2.5mm2
or more
AWG#14
or more
047: 380V 400 415 380 400 415 380 400 415
048: 440V 460 480 440 460 480 440 460 480
3.5mm2
or more
4.0mm2
or more
AWG#12
or more
Connect the lines to the terminals corresponding to the main power supply.
2. Use a round crimp-style terminal for connection.
3. The terminal block is for three poles and the earth wire is
to be secured on the enclosure with a screw
Unassigned(Do not connect to this terminal)
For connection of
optional protection
equipment(OP)
Remote
control
Unassigned(Do not connect to this terminal)
Alarm level output
(OFF: Level 1, ON: Level 2)
For connection Error / Power failure
of machine
synchronization
Pump
thermistor Normal operation
(Earth)
DANGER
3 Connection to signal terminal block(X2M)
Warning
output
1. Always install an all-pole (3-pole) circuit breaker (to be prepared
by you) of the specified capacity on the main power supply.
*All contact distances must be at least 3 mm.
2. Always ground the unit. Since a noise filter is installed, there
is a risk of electrical shock without proper grounding.
3. Before opening the electric component box, always turn off the power,
and wait for 5 minutes until internal high voltage has been discharged.
4. Do not energize the equipment with the electric component
box kept open.
9 10 11 12 13 30 31 60 61 62 63 64 65 66 67
MR30W
CAUTION
MR30X
(X2M)
MR30Y
Interior of oil cooling unit
1. Straight crimp terminal and wiring diameter
Wiring diameter
Straight pin
terminals
*
JIS cable
IEC cable
UL cable
0.25mm2∼1.25mm2
0.3mm2∼1.5mm2
AWG#22∼#16
4 Signal output time chart
(1)Alarm/operation status output chart
Remote operation (between【10】and【11】)
Operation status
ON
Signal output
Normal(NO contact)
60−61
Error / Stop(Power OFF)
(NC contact)
60−63
Error level(NO contact)
60−64
Pump operation(NO contact)
61−62
Normal
Level 1
error or
Lock
Normal
Level 1
error or
Lock
OFF
Power failure
Level 2
(Power OFF)
error
Normal
Level 1
error or
Lock
Normal
Level 1
error or
Lock
Level 2
Power failure
error
(Power OFF)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(2)Warning output chart
Operation status
Signal output
Warning output(NO contact)
CAUTION
66−67
Non-warning status
Power failure
Level 2
(Power OFF)
error
Electric wiring connection instruction diagram
2. Use a straight crimp-style terminal for connection.
3. Use stranded wires for electric connection.
4. The wiring size is 0.5 mm2 to 1.5 mm2 in the case of duplex cable according
to IEC. If using stripped wire, make the stripped length 9 mm to 10 mm.
*Recommended models and manufacturers:
TGN TC−1.25−9T (NICHIFU Co., Ltd.)
APA−1.25N (DAIDO SOLDERLESS TERMINAL MFG. CO., LTD.)
1. To avoid the effects of noise, connect the power wire by
cutting it to the proper length so that no excess wire comes
into contact with the control board or others.
2. To perform remote control, remove the short-circuit wire
between [10] and [11] and install an operation switch(to be
prepared by you).
3. The mode is set to“Lock mode(Stop mode)”by default.
Before starting operation, follow the procedure to release the
Lock mode from the operation panel. Refer to the operation
manual for the unlocking procedure.
4. The unit is provided with a misoperation prevention switch
(PROTECT) to reject setting from the operation panel.
If you want to use this function, make the necessary setting
referring to the operation manual.
Supporting information
MR52Pa
Supporting
information
Warning status
Power failure
Level 2
(Power OFF)
error
ON
OFF
1. The following electric wires can be used on the
3. For [10] to [13], please prepare contacts to meet
terminal block for straight crimp-style terminals.
the condition of minimum applicable load 12V DC
Single wire: φ0.
57∼φ1.
44(AWG#22∼#16)
and 5mA.
2
25mm2∼1.
25mm(AWG#
22∼16) 4. When the length of the thermistor to be connected
Stranded wire: 0.
2. Load applicable to [60 - 64] and [66 - 67] is as follows:
to [30] − [31] is longer than 10m, or the wiring is
Min. applicable load: 10mV DC, 10μA or more
routed in a poor noise environment, use shielded
Max. applicable load: 30V DC, 2A(Resistance load)
wire.
24
Supporting
information
Notes for installing external piping
If the external pressure loss(site piping resistance)
exceeds the specified use range, there may occur
phenomena such as abnormal noise of the pump(relief
noise, noise of cavitation)
, decrease of cooling capacity
and control failure of oil temperature. Keep the external
pressure loss within the specified use range.
●Relationship between oil flow rate
and external pressure loss
An AKZ 9 series Oil Cooling Unit incorporating a pump of the
circulation type has the characteristics shown below. When the
external pressure loss (△p) is 0.5 MPa or less, the rated flow rate
(Q0) is achieved, but when the external pressure loss exceeds 0.5
MPa, the flow rate becomes lower than the rated flow rate.
1. Suction-side piping
Keep the suction vacuum pressure within the range
between -30.7 and 0kPa.
The use of a suction filter of 100 to 150 mesh is
recommended.
2. Discharge-side piping
Keep the pressure loss of the discharge-side piping at
0.5 MPa or less.
3. Do not install a stop valve on the suction or discharge
side. When a stop valve must be installed on the
discharge side out of necessity, use a 0.5Mpa relief
valve along with the stop valve.
4. Calculation of piping resistance
Determine the oil piping size by calculating the piping
resistance according to the following equation:
Good example
Circulation volume or flow rate Q(L/min)
Usable range
Piping resistance △P=0.595 ×ν×Q×L/D4
(For use of general hydraulic oil and lubricant)
Q0
Unusable range
A
B
AKZ329・439・
569・909
Q1
AKZ149
C
0
0.5 0.6 0.7 0.8
External pressure loss △P(MPa)
Q
(L/min)
:Flow rate(Q0: Rated flow rate)
△P
(MPa)
:External pressure loss
A:Status when the external pressure loss is“0”
B:Status when the external pressure loss is“0.5Mpa”
(MPa)
△ P:Piping resistance
(mm2/s)
ν:Dynamic coefficient of viscosity
−Refer to the Viscosity / Temperature Chart.
Q:Flow rate(L/min)
L:Piping length(m)
D:Internal piping diameter(mm)
(Cracking pressure of relief valve)
C:Status when the external pressure loss is large
and the oil flow rate is“0”
.
■Viscosity / Temperature Chart
Dynamic
viscosity
Supporting information
Note)Design the site piping to withstand a pressure of at least 1.0 MPa.
mm2/s
10
20
-10
30
40
0
50
Temperature
60 70 80
10
20
90
30
Example of viscosity
(dynamic coefficient of
viscosity)
100 110 120 130 140 150 °
F
40
50
60
70℃
10,000
In winter: 195mm2/s
ISO VG32 Oil
(temperature 5℃)
5,000
3,000
2,000
In summer: 29mm2/s
ISO VG32 Oil
(temperature 40℃)
1,000
Notes for installing external piping
500
400
300
200
150
68
100
75
46
50
40
30
32
20
22
15
10
10
9.0
8.0
7.0
5
6.0
5.0
2
4.0
3.0
2.0
-10
10
25
△P >0.5MPa
↓
The oil flow rate
becomes Q1, lower
than the rated flow rate.
Bad example
△P ≦0.5MPa
↓
The rated flow rate(Q0)is
achieved.
0
20
30
40
10
20
50
60 70 80
Temperature
30
90
40
50
60
70℃
100 110 120 130 140 150 °
F
9
AKZ
SERIES
Supporting
information
Notes for handling
●Important notes to be observed regarding the main machine side
(machine tools and industrial machine)
1. When adverse transport conditions are expected in transporting the machine overseas or elsewhere, special
precautions should be taken in the packaging and transportation method so as to avoid the application of
excessive force on Oil Cooling Unit(this unit)
.
2. Oil Cooling Unit(this unit)does not incorporate a flow switch for checking the oil supply and a temperature
switch for abnormal supply of oil temperature(high temperature or low temperature)
. So, please provide a
protection device such as a flow switch and a temperature switch on the main machine side.
Notes for operation and cooling capacity
1. Do not use Oil Cooling Unit for cooling a liquid at 50℃ or more. Start to operate Oil Cooling Unit at the
same time as the main machine or before liquid temperature rises to 40℃.
2. Do not place an object that hinders ventilation within 500mm of the suction port or discharge port.
3. If the air filter is clogged, the cooling capacity is reduced. Clean the air filter(wash with hot water or
clean with air)periodically once every two weeks to prevent clogging.
Notes regarding liquid usable with Oil Cooling Unit
1. The notes are given in the table below.(○ symbol・
・
・Can be used, × symbol・
・
・Cannot be used)
2. Do not use the liquid listed below as“not usable”
(Marked with“×”
)
.
Special notes
Mineral hydraulic oil
○
×
Coolant fluid
● Water-soluble cutting
and grinding liquid
● Non water-soluble
cutting and grinding oil
×
Ethylene glycol
(Antifreeze liquid)
×
×
Water(Industrial water)
Inflammable liquid like fuel
Liquid equivalent to special flammables,
alcohol, first class petroleum and second
class petroleum of the fourth group
hazardous materials specified according
to the Fire Defense Law
×
×
Drugs
Liquid for food products
Notes for handling
Nonflammable hydraulic oil
● Ester phosphate series
● Chlorinated hydrocarbon series
● Water - Glycol series
● W-O & O/W emulsion series
(High-aqueous hydraulic oil)
Supporting information
Lubricant
・The third class petroleum and fourth class
petroleum of the fourth group hazardous
materials specified according to the Fire
Defense Law, and oil equivalent to
discoloration No. 1 according to the copper
corrosion test method(JIS K2513)of
petroleum products
・Oil equivalent to NAS 10 level according to
the pollution level
AKZ 9 Series
Drinking water, water for cooling food
products, etc.
×
26
Supporting
information
Notes for handling
*Before operating this unit, be sure to read the operation manual and properly understand it.
●Instructions for safe operation
Signs and
Instructions
D A N G E R・
・
・Failure to observe the instruction may cause an imminent hazardous situation that may result in personal death or serious injury.
・
・Failure to observe the instruction may result in personal death or serious injury.
WARNING・
・
・Failure to observe the instruction may result in personal injury or damage to the property.
CAUTION・
1 General instructions
[
DANGER] ʱUse the equipment only in accordance with the intended specifications(specified in brochure, specification sheet, operation manual, caution plate).
[
DANGER] ʲNever operate the equipment in an explosive atmosphere
[
DANGER] ʳDo not disassemble, repair or modify the equipment by yourself.
[
DANGER] ʴAlways comply with the laws and regulations for safety(Industrial Safety and Health Law, Fire Defense Law, JIS B 8361 Guidelines of Hydraulic System).
[
WARNING] ʵCaution in the event of refrigerant leak
・Ventilate a room adequately(to avoid the risk of suffocation)
.
・Avoid direct contact of the refrigerant with skin(to avoid the risk of frost injury)
.
・In the event of inhalation of a great deal of refrigerant, contact with skin, and refrigerant in the eye, seek medical attention immediately.
[
WARNING] ʶIn the event of an abnormal condition, stop operation promptly, investigate the cause of the problem and take appropriate remedial measures.
[
CAUTION] ʷDo not use the unit in atypical environments (locations subject to high temperatures, high humidity, or
[
CAUTION] ʸInstall a flow switch and temperature switch on the main machine to protect the main shaft and others.
[
CAUTION] ʹDo not get on the equipment or place an object on the equipment.
a lot of dust, contamination, particulate matter, steam, oil mist or corrosive gases: H2S,SO2,NO2 or CL2).
2 Instructions for transportation
Supporting information
[
DANGER] ① When hoisting the equipment, check its weight and use the eye plates and hangers on the equipment properly.
[
WARNING] ② Do not get approach the equipment while it is being hoisted and moved.
[
CAUTION] ③ When moving the equipment, take appropriate measures for fall prevention.
[
CAUTION] ④ Do not tilt the equipment 30 degrees or more while transporting the equipment(including during storage).
3 Instructions for installation
[
WARNING] ① Install the equipment on a rigid, level foundation and secure it appropriately.
[
CAUTION] ② Do not place an object near the suction port and discharge port of the equipment.
4 Instructions for wiring and piping installation
[
DANGER] ① Wiring and piping installation should be performed by a person with specialized knowledge and skills.
[
DANGER] ② Always use a commercial power supply for the power source. (The use of an inverter power supply may cause burn damage).
[
DANGER] ③ Connect the wiring for power supply in accordance with the electric wiring instruction diagram of the specification sheet and operation manual.
Notes for handling
[
DANGER] ④ Ground the equipment properly.
[
WARNING] ⑤ Install the wiring in accordance with the standard by checking the electric schematic diagram.
[
CAUTION] ⑥ Always install a dedicated breaker (molded case circuit breaker) appropriate for the capacity of Oil Cooling Unit on the main power supply on site.
[
CAUTION] ⑦ Check to see that the oil piping has the pressure resistance of 1MPa or more and install the piping appropriately.
5 Instructions for trial run
[
CAUTION] ① Check to see that the main machine is in a safe status(not activated)before starting the trial run.
[
CAUTION] ② Check to see that the oil piping and electric wiring are correctly connected to the main machine and that there is no looseness in connections and joints.
[
CAUTION] ③ Disable the operation lock of the equipment(Oil Cooling Unit)before starting the main machine.
[
CAUTION] ④ Check to see that the required amount of oil is in the oil piping system and that the piping is not blocked in the middle.
6 Instructions during operation
[
DANGER] ① Do not splash water or liquid on the equipment.
[
WARNING] ② Do not push your finger or an object into gaps of the equipment.
[
CAUTION] ③ Do not touch the heated exhaust port of the equipment.
7 Instructions for maintenance and inspection
27
[
DANGER] ① Perform maintenance and inspection with the equipment kept open. Working in a closed status may result in suffocation due to the leak of refrigerant.
[
DANGER] ② Always turn off the main power supply before starting maintenance and inspection.
[
DANGER] ③ Wait for five minutes after turning off the main power supply and start maintenance and inspection operation.
[
DANGER] ④ Do not operate the equipment with the cover of the equipment opened.
[
CAUTION] ⑤ Wear protective gear such as gloves and an eye protector when performing maintenance, inspection and cleaning.
[
CAUTION] ⑥ Clean the air filter periodically(once every two weeks in general)
.
[
CAUTION] ⑦ Keep oil cleanliness to NAS 10 level or less according to the pollution level.
[
CAUTION] ʸCheck the oil level in the tank and ensure that it is between the yellow line and the red line.
[
CAUTION] ʹInspect the underneath (drain pan) of the oil cooling unit once every six months, and if oil has accumulated, discharge it through the oil drainage port.
9
AKZ
SERIES
Supporting
information
Method of selection of Oil Cooling Unit
Unit conversion formula ● 1kW=860kcal/h
1.Select Oil Cooling Unit having a cooling capacity 20 to 30% larger than the heat release value from the
machine tool.
2.Since the cooling capacity of Oil Cooling Unit varies with the change of liquid temperature(inlet liquid
temperature)and room temperature, it is necessary to clarify the liquid temperature and room temperature
conditions to select appropriate Oil Cooling Unit.
3.Three methods are shown below as a guide for estimating the heat release value from the machine tool.
For determining the heat release value eventually, it is necessary to conduct tests and determine the
exact heat release value for selecting appropriate Oil Cooling Unit.
●Calculation method of heat release value from main machine
for the selection of appropriate Oil Cooling Unit(as a general guide)
In the case of cooling of main shaft of machining center
●Method 1: To estimate the heat release value from the temperature
difference between the supply oil and return oil
Q=2.778×10 -7Cp・γ・Vs・△T
T1℃
V sm 3/h
Q : Heat release value
(kW)
・
・
・1967.4J/kg℃
Cp : Constant pressure specific heat(J/kg℃)
(kg/m3)
・
・
・876kg/m3
γ : Weight volume ratio
T2℃
Oil Cooling
Unit
(m3/h)
Vs : Oil flow rate
(℃)
・
・
・T2ーT1
△T: Temperature difference
M
E.g.)When“Vs”is 18m3/h(30L/min)and“△T”is 5℃
Main machine
Q=2.778×10-7×1967.4×876×1.8×5 Oil tank
=0.479×1.8×5≒4.3kW
Find the maximum gradient of oil temperature increase
To find the maximum gradient of the oil
temperature, it is necessary to measure △t every
one minute during the first 10 minutes.
Tank oil
temperature
t1
Q=2.778×10 -7Cp・γ・V・△t/H
(kW)
Q : Heat release value
・・・1967.4J/kg℃
Cp : Constant pressure specific heat(J/kg℃)
(kg/m3)
・
・
・876kg/m3
γ : Weight volume ratio
t2
(m3)
V : Total oil quantity
0
0.5 1.0 1.5 2.0 2.5 3.0
Time(h)
(℃)
・
・
・t 1ーt
△t : Temperature difference
2
(h)
H : Time
E.g.)When the total oil quantity is 300L(0.3m3)and“△t”
is 10℃.
Q=2.778×10-7×1967.4×876×0.3×10 =0.479×0.3×10≒1.4kW
●Method 3: When motor output loss is considered to be the heat release value
Q : Heat release value
(kW)
Q=H・
η
100
H : Motor output
(kW)
…For driving the main shaft
Method of selection of Oil Cooling Unit
Oil temperature(℃)
Ambient
temperature
( )
Supporting information
●Method 2: To estimate the heat release value from the increase rate of
oil temperature in the tank
η : Motor output loss
(%)
E.g.)When the output loss is 30% for the motor output 7.5 kW → The output
loss is 30% or so in general(Cooling of main shaft head)
Q=7.5×0.3=2.3kW
28
Supporting
information
Table of history of Oil Cooling Unit for cooling main shaft(Circulation type)
AKS→AKZ
Horsepower Cooling capacity
HP
W
10,000
9,500
3.0
Old
New
AKS303K AKS303AK
◇
◇
AKZ306 AKZ(S)907
◇
9,000
◇
AKZ908
AKZ909
◇
◇
8,500
8,000
7,500
7,000
6,500
6,000
5,500
2.0
5,000
AKZ206
☆
☆
AKS205K
AKS203K AKS203AK
☆
Supporting information
1.2
AKZ(S)437 AKZ438
◎
3,500
2,500
AKS100Z
AKS105K AKS105AK
AKS103K AKS103AK AKS104K
□
□
□
□
■
AKZ106
□
1,500
Table of history
1,000
0.3
☆
◎
AKZ439
◎
AKS53K
AKS54K
△
△
AKS54AK AKS55K
△
AKZ(S)327 AKZ328
□
□
※
AKS55AK
AKZ(S)147
△
△
AKS33K
AKS35K
AKS35AK
○
○
○
AKZ329
□
□
AKZ148
AKZ149
○
○
AKZ(S)257
2,000
0.5
☆
4,000
3,000
1.0
☆
AKZ569
☆
4,500
1.5
AKZ(S)567 AKZ568
○
500
0
Series name AKS 3 series
AKS 4 series
AKS 5 series
AKS-Z AKZ 6 series AKZ 7 series AKZ 8 series
Sales starting time
−
'87.5
'86
'87
'88.1∼10
'98.12
'88
Discontinuation time
'87.5
'02.3
'88
'88
'93.3
'02.3
'97.3
ON−OFF type
'96.8∼10 '01.10∼'02.2
'02.9
'05.3
'02∼
Conventional type
AKZ 9 series
'10∼
'12∼
Current model
Inverter type
Note)1. The larger the last number of a model name, the newer the series
(For instance, AKS35K is newer than AKS33K)
.
In addition, a model having the last alphabetic characters“AK”is newer than a model ending with“K”only.
(For instance, AKS35AK is newer
than AKS35K)
.
2. The cooling capacity is represented by the value at the standard point and at 60 Hz for all models.
3. The dimensions of the equipment may be changed on a newer type and older type on some models. Please check the dimensions on the
brochure and specification sheet(outline drawing)for selecting your equipment.
When you are about to buy new equipment due to a failure of the equipment or for other reasons, please check the conditions of new equipment
and select an appropriate type.
4. All the models have been changed to the inverter type since 2002.
5. AKSZ
(S)
“7”series uses new refrigerant R407C, AKZ“8”
, AKZ“9”series uses new refrigerant R410A, and all other models use R22.
6. Existing units of 1HP class(AKS105AK, AKZ
(S)257 class)were integrated into AKZ328 of 1.2HP class.
29
9
AKZ
SERIES
Supporting
information
Daikin Oil Cooling Unit service network
What Daikin can offer as a global manufacturer
of air conditioning equipment
Daikin can offer you speedy delivery and reliability through a broad-based
network in seven countries and regions throughout the world.
Korea
U.S.
Japan
China
India
Taiwan
Thailand
Singapore
Please contact Daikin Sales Counter for servicing of Oil Cooling Unit in countries outside Japan.
Daikin is ready to offer you service in conjunction with the sales agents of our Air-conditioning
and Hydraulic Divisions located in seven countries and regions worldwide.
Country/Region
Locations
Beijing
Shanghai
China
Shanghai
Korea
Seoul
Taiwan
Taipei
Singapore
Singapore
Thailand
Bangkok
India
New Delhi
U.S.
Illinois
大金空調技術(上海)有限公司
DAIKIN AIR CONDITIONING TECHNOLOGY (SHANGHAI) CO.,LTD.
大金空調技術(広州)有限公司
DAIKIN AIR CONDITIONING TECHNOLOGY (GUANGZHOU) CO.,LTD.
◎ 大金工業株式会社 上海事務所 液圧控制課
DAIKIN SHANGHAI OFFICE OIL-HYDRAULICS DIV.
◎ KD HYDRAULICS,LTD.
Service network
Guangzhou
Company name
大金空調技術(北京)有限公司
DAIKIN AIR CONDITIONING TECHNOLOGY (BEIJING) CO.,LTD.
Supporting information
Overseas service network
HO TAI DEVELOPMENT CO.,LTD.
DAIKIN ASIA SERVICING PTE. LTD.
SIAM DAIKIN SALES CO., LTD.
DAIKIN AIR CONDITIONING INDIA PVT.LTD
DELHI BRANCH
◎ ALL WORLD MACHINERY
◎Sales agents of hydraulic equipment.
Others are the sales agent of air conditioning equipment.
(As of July 31, 2012.)