Pump Packaged Brochure
Transcription
Pump Packaged Brochure
AUSTRALIA PTY LTD PACKAGED PUMP STATIONS TM pump systems “Trusted Quality & Service” POLYETHYLENE PUMP WELLS MPPS��� SPECIFICATIONS Depth: 700mm Inner Diameter: 410 mm Nominal Litres: 100 Access Cover: 450 x 450mm Approximate Weight: 15kg MPPS��� SPECIFICATIONS Depth: 900mm Outer Diameter: 730mm Inner Diameter: 650mm Nominal Litres: 250 Access Cover: 600 x 600mm Approximate Weight: 25kg MPPS��� SPECIFICATIONS Depth: 1200mm Outer Diameter: 1120mm Inner Diameter: 1000mm Nominal Litres: 900 Access Cover: 600 x 600mm Approximate Weight: 45kg ���L - ���L POLYETHYLENE PUMP WELLS ����L - ����L CONSTRUCTION • Polyethylene tank • All in-tank fittings incorporated in the packaged pump station as follows: PVC ball valve, non-return valve and barrel unions; PVC interconnecting pipework • Inlet Pipe to be installed by plumber unless otherwise specified APPLICATIONS Raw Sewage Trade Waste Effluent Stormwater PUMP OPTIONS Single Pump with or without Dual Pumps guide rails } MPPS���� SPECIFICATIONS Depth: 1600mm Outer Diameter: 1120mm Inner Diameter: 1000mm Nominal Litres: 1200 Access Cover: 600 x 600mm Approximate Weight: 62kg MPPS���� SPECIFICATIONS Depth: 2125mm Outer Diameter: 1730mm Inner Diameter: 1600mm Nominal Litres: 3000 Access Cover: 900 x 600mm Approximate Weight: 165kg TYPICAL SINGLE PUMP STATION Poly Pedestrain Lid Liquid Level Alarm (OPTIONAL) Outlet PVC Ball Valve PVC Check Valve / Union Automatic Submersible Pump High Level Alarm (OPTIONAL) Pump Float Switch TYPICAL DUAL PUMP STATION Dual Pump Controller access cover Optional guiderailswith auto-couplings for quick removal and reinstallation of pumps Selection of PVC, bronze or stainless steel valves available. Rotomoulded polyethylene tank with heavy duty ribbing adds strength assists in antifloatation. PVC or polyethylene pipework for a long, maintenance free life. Float switch and level probe options available for reliable pump control Dual heavy-duty submersible sewage or stormwater pumps. wide rang of options available. Moulded inlet stubs ensure leak-free installation no damage to the environment. ACCESS COVERS ACCESS COVER OPTIONS FOR KPPS���L PUMP STATION MODEL NO. DESCRIPTION HAC44LD HAC44HD HAC44LDG 450x450 Light Duty Cast Iron Solid Top 450x450 Heavy Duty Cast Iron Solid Top 450x450 Light Duty Galvanised Grate CLASS B D B ACCESS COVER OPTIONS FOR KPPS���, ��� & ����L PUMP STATION MODEL NO. DESCRIPTION HAC66LD HAC66HD HAC66LDG 600x600 Light Duty Cast Iron Solid Top 600x600 Heavy Duty Cast Iron Solid Top 600x600 Light Duty Galvanised Grate CLASS B D B ACCESS COVER OPTIONS FOR KPPS����L PUMP STATION MODEL NO. DESCRIPTION HAC69LD HAC69HD HAC69LDG 600x900 Light Duty Cast Iron Solid Top 600x900 Heavy Duty Cast Iron Solid Top 600x900 Light Duty Galvanised Grate Other options available on request including: • Concrete infill covers • Multipart covers • Paver infill covers • Tile infill covers • Stainless steel or brass edged covers • Round Covers • Gas tight covers • Bolt down covers CLASS B D B DUAL & SINGLE PUMP CONTROLLERS OUTER DOOR CONTROLLER OPTION LOCKABLE INNER DOOR CONTROLLER OPTION Applications • Submersible Sewage • Submersible Storm Water • Constant Pressure Systems • Hot Water Circulation Systems • Transfer Pumping Systems Hardware Features • IP 65 Weather Proof, Powder Coated Metal Enclosure c/w removable gland plate • Lockable Main Isolator • Individual Pump Isolation • Circuit Breaker protected Control Circuit • Low Voltage Control and input Circuitry • Advanced Micro Processor Control Module • Distinctive, Highly durable and aesthetically attractive Electronic Keypad • Auto/Off/Manual Operation of Pumps • Thermal Overload Protection of Pump Motors • LED Indicator Lights for System Status indication • Visual and Audible Alarms c/w Mute Switch • User friendly, clearly labelled, Din Rail mounted, Input and Output Terminal Connection Features • Auto Alternation of Pump Duty (Dual Pump Applications) • Provision for 4 digital + 1 Analogue inputs (typically Low Level, Stop/Start, Standby In and High Level) • Lamp, Strobe and Buzzer Test feature • Level Alarm Delay feature avoiding nuisance tripping • Maximum Run Time and Auto Alternation Feature • Anti Seize/Freeze feature, for Low Use and Seasonal Pumping applications • Maximum Idle Time Feature, for “pump out ” of residual in Pump Well situations • Smart “Auto Silencing” and “Chirp Mode” audible Alarm • Delayed Start and Minimum Run Time Feature • Delayed Stand by Pump Start, avoids two motors starting simultaneously • Optional “Time Out” on Manual Pump Mode automatic reset to Auto • No Flow/Pressure – Inbuilt Timer feature • Interconnectable with Remote Status Indicator panel, via simple data connection • Interconnectable with Building Monitoring System Module, via simple data connection LIQUID LEVEL ALARMS 1265 Series Alarms The Maxijet Liquid Level Alarms are designed to provide warning indication when storage (Effluent, Grey Water or Rain Water etc) tank is either empty or full. Warning indication is determined by a float switch. Warnings are; Audio (buzzer) Visual (LED Pilot Light and/or Strobe) The Buzzer can be muted via a mute button. If not muted the Audible buzzer will automatically silence after 5 minutes. If a continuously sounding audible alarm is required, this can be done by changing the Jumper position on the circuit board. The visual alarms will continue to remain on, until the alarm condition is eradicated. A standard feature of the Level Alarm is a ‘Voltage Free’ (5Amp rated) output for connection to auxiliary devices. Controller can be installed up to 50m from the tank being monitored. Float Switch cabling is ‘safe’, low voltage circuitry. FLOAT SWITCHES 9000 Series Float Switches The 9000 Series Maxijet Float Switch, which utilises an innovative, yet simple ‘fool proof’ switching concept, has greatly enhanced Float Switch reliability. The positive micro–switching eliminates the possibility of more than one circuit being in operation at any one time. The design innovation of the Switch is the ‘sliding detent action’ which obviates wave induced oscillation (common in mercury type switches) while maintaining consistency in switching level accuracy. The smooth robust ABS switch housing on the 9006 and 9010 models, prevents adhesion of foreign materials. Our extensive range of switches, cable types and cable lengths ensures we have the ‘right’ product to suit the application. Packaged Pump Stations AUSTRALIA PTY LTD FAX: (03) 9336 1099 EMAIL: [email protected] REQUEST A QUOTATION PIT SIZE MPPS100 (100 Ltr) MPPS200 (200 250 Ltr) MPPS900 (900 Ltr) MPPS1200 (1200 Ltr) MPPS3000 (3000 Ltr) LID TYPE Class A poly Pedestrian Class B cast iron solid top (Light Duty) Class D cast iron solid top (Heavy Duty) Class B galvanised grate (Light Duty) Class D galvanised grate (Heavy Duty) Other __________________________________________ PUMP APPLICATION Single pump Dual pumps Stormwater Greywater Sewage POWER SUPPLY 1 Phase 240 volt 3 Phase 415 volt CONTROLLER TYPE Single pump controller Dual pump controller w/ high level alarm w/ high level alarm High Level alarm only FLOW REQUIREMENT Litres / second @ metre lift mm pipe size metre head metre run COMMENTS Store: Name: Address: City: Phone: Email: State: Postcode: Submit