Liberator
Transcription
Liberator
! Group Product Technical Specification G.P.T.S. No 1105 Issue 02/2014 Liberator Mechanical Smoke Ventilator Type T-LIBERATOR Type W-LIBERATOR-FCO The T-Liberator and W-Liberator mechanical smoke vents may be used for day to day ventilation as well as for smoke extract. Type W-LIBERATOR-Flap Confidential Typical applications include: Single and multi storey shopping centres Single and multi storey industrial buildings and warehouses Atria and complex buildings Enclosed car parks Stairways Theatres © Colt International Licensing Ltd 2014 ! Issue 04 Group Product Technical Specification Page 1 . 1 Date February 2014 G.P.T.S. T-Liberator GENERALINFORMATION 1.1 N° 1105 Applications Suitable for mechanical smoke control with an option to provide day to day ventilation. Installation up to max. 20° inclination angle. All units fulfill the F200, F300 and F400 categories in accordance with EN 12101-3, as well as snow classes SL 125 (125N/m²) - TL version and SL 500 (500 N/m²) - WL version in accordance with EN 12101-3. They are CE marked. 1.2 Limitations of use - High wind pressures High buildings Installation in coastal regions The undesirable effect of installation in such places or in such conditions can be that the non-return shutters clatter. 1.3 Construction Major components made of aluminium alloy AlMn1Mg0,5. An aerodynamically shaped square aluminium shroud discharges air vertically. Four non-return shutters in the shroud ensure that the ventilator closes automatically when the fan is at rest. An internal rain channel and neoprene seals guarantee that the ventilator is rain-proof. The unit is available with a single speed motor only. 1.4 Operation The movement of the fan impeller produces a negative pressure and draws air out of the building. Simultaneously, a cushion of pressurised air builds up above the impeller, which opens the return flaps and allows the smoke to be sucked out of the room to the outside. When the power is switched off, the impeller gradually comes to a standstill. Once the impeller stops moving, four sprung non-return shutters in the shroud close automatically. 1.5 Product stats group B 01. 1.6 Performance classes Requirements of EN 12101-3 Time-Temperature Class F200 200°/120Min Time-Temperature Class F300 300°/60Min Time-Temperature Class F400 400°/120Min Snowload Class SL 125 125 N/m² Snowload Class SL 250 250 N/m² Snowload Class SL 500 500 N/m² Powered Extract Unit with double function of smoke and day to day extract Opening time for flap(s) Closing time for flap(s) Yes = requirements fulfilled No = requirements not fulfilled Confidential T-Libe ra tor TL/3/... yes yes yes yes no no yes Immediate Immediate © Colt International Licensing Ltd 2014 W -Libe ra tor W L/3/../FCO W L/3/../FLAP yes yes yes yes yes yes not applic. yes not applic. yes not applic. yes yes yes 16 sec. 150 sec. 22 sec. 22 sec. ! Issue 04 Group Product Technical Specification Page 2.1 Date February 2014 G.P.T.S. N° 1105 T-Liberator TECHNICALINFORMATION 2.1.1 Dimensions TL/3 Size min. upstand opening A TL/3/06 TL/3/08 * ** Base dimensions* E G K max. mm mm mm mm 1200 - 915 1067 600 670 255 340 CxD mm Std. mm N5/SB** min. mm 725 875 950 1200 740 980 max. mm 950 1250 Std. mm N5/LB** min. mm 1250 - 1001 - Standard N2, N3 and N5 base dimensions correspond with the standard N4 base minus 50 mm. SB = Short base, LB = Large base 2.1.2 Weights TL/3 2.1.3 Cable requirements TL/3 Size Weight kg TL/3/06/NF/23 TL/3/06/NF/16 TL/3/08/NF/16 TL/3/08/NF/12 61 61 77 77 Confidential - halogen free, not flammable, norm NF C 32-070 Non flammable (Norm IEC 332-1) Temperatures for continuous operation: -60°C to +400°C, max +500°C Cable type: MA-VAS 4x1,5mm² or MA-CNVAS 4x2,5mm² Any contractor which lays the cable on cable trays or places it into the ceiling must be qualified to carry out such work. The cables provided with the product are not allowed to be used outdoors. © Colt International Licensing Ltd 2014 ! Issue 04 Group Product Technical Specification Page 2.2 Date February 2014 G.P.T.S. N° 1105 T-Liberator TECHNICALINFORMATION 2.1.4.1 Performance data TL/3 - 300°C / 60min (F300) Size TL/3/08.. 16 Airflow RPM Voltage Current Power m³/h m³/s min-1 Volt/Ph. A kW 21180 5.88 940 380-415/3 3,71 1,50 cos Wiring Average sound pressure level* dB(A) Motor Item-Nr. WEG 69.5 0.73 354889 2.1.4.2 Performance data TL/3 - 200°C / 120min or 400°C / 120min (F200 / F400) TL/3/06.. 23 16 TL/3/08.. 16 12 * m³/h 14815 9675 m³/s 4.12 2.69 min-1 1420 915 Volt/Ph. 380-420/3 380-420/3 A 3.19 1.97 kW 1.50 0.75 cos 0.83 0.76 21180 15760 5.88 4.38 940 705 380-420/3 380-420/3 3.78 2.42 1.50 0.75 0.74 0.63 dB(A) ABB WEG 72.5 317935 318948 60.5 317932 318945 69.5 63.5 317933 318946 317934 318947 Average sound pressure level measured at 3m distance in free field conditions. IP 55 rated, with insulation class H. 2.1.5 Acoustic data TL/3 Measured without ducting. Ducting can be added, but this alters both the acoustic and volume flow characteristics. Size Sound power level (dB) 63 125 Centre octave frequency (Hz) 250 500 1,000 2,000 4,000 8,000 Mean sound power level dB(A) inlet discharge inlet discharge 66.0 71.0 60.5 60.5 73.0 77.0 73.5 75.0 85.0 95.0 77.0 76.5 85.0 85.0 75.0 74.0 85.0 83.0 74.0 73.0 82.0 80.0 72.0 71.5 78.0 76.0 64.5 64.0 68.0 66.0 55.5 55.0 89.0 90.0 79.0 78.0 inlet discharge inlet discharge 69.0 69.0 68.0 69.0 83.0 84.5 81.5 86.5 84.5 87.5 79.0 83.0 84.0 84.0 76.5 78.5 83.0 81.5 76.0 74.5 81.0 78.5 74.0 72.0 76.5 74.5 67.0 64.5 66.0 63.5 57.5 54.5 88.0 87.0 81.0 81.0 Position TL/3/06.. 23 16 TL/3/08.. 16 12 Confidential © Colt International Licensing Ltd 2014 ! Issue 04 Group Product Technical Specification Page 2.3 Date February 2014 G.P.T.S. N° 1105 T-Liberator TECHNICALINFORMATION 2.1.6 Fan curve TL/3, 06 size Type: TL/3/06/23/.. Value∑ ζ Statis pressure diference (Pa) TL/3/06/16/.. Air flow V (m³/s) 2.1.7 Fan curve TL/3, 08 size Type: TL/3/08/16/.. Value∑ ζ Statis pressure diference (Pa) TL/3/08/12/.. Air flow V (m³/s) Confidential © Colt International Licensing Ltd 2014 ! G.P.T.S. Group Product Technical Specification Issue 04 Page 4.1 Date February 2014 W-Liberator GENERALINFORMATION 4.1 N° 1105 Applications Mechanical smoke control with facility for day to day ventilation. WL can be fitted either with a FCO ventilator or with a flap. The flap version can be installed in either walls or roofs. There are two choices of unit: WL fulfils categories F200, F300 and F400 in accordance with EN 12101-3. WL with flap version fulfils snow class SL 500 (500 N/m²) in accordance with EN 12101-3. 4.2 W-Liberator with flap Major components made of aluminium alloy AlMn1Mg0,5. Motor guard painted steel, hinges stainless steel, 30 mm thick mineral wool insulation for double skin external flap. 4.3 Operation of W-Liberator with flap For day to day ventilation The fan starts up and simultaneously the flap is opened: a gas spring pushes the flap and simultaneously the worm gear motor unwinds the drum and steadily lets the cable go. The external flap opens to approximately 70° for day to day ventilation, owing to the geometry of the safety locking mechanism. Once the flap has reached the open end position, a built-in limit switch shuts off the opening mechanism. The external flap is closed automatically once the fan motor has been switched off using the built-in worm gear motor coiling up the cable. Once the flap has reached the closed end position, a built-in limit switch shuts off the closing mechanism. For smoke control In a fire situation there is a double safety mechanism: If the smoke is cool then the fan will start up and the flap will open as above. However if it is hotter than 93°C, then a solder link will part the cable and the flap will automatically open to 90° under pressure from the gas spring. Should the gas spring fail in its open position, a safety device ensures that the flap does not close again. Confidential © Colt International Licensing Ltd 2014 ! G.P.T.S. Group Product Technical Specification Issue 04 Page 4.2 Date February 2014 W-Liberator GENERALINFORMATION 4.4 N° 1105 W-Liberator with FCO louvred ventilator All principal components are manufactured from corrosion resistant aluminium AlMn1Mg0,5. Guards: steel coated. WL/03/06/... is delivered with this aluminium bladed FCO unit: FCO/1ST /0911/A2X/M1C230/1F93/X/FR/N2. WL/03/08/... is delivered with this aluminium bladed FCO unit: FCO/1ST/1013/A2X/M1C230/1F93/X/FR/N2. 4.5 Operation of W-Liberator with FCO louvred ventilator For day to day ventilation The fan starts up and simultaneously the FCO opens under a spring, since the FCO ventilator is equipped with a 230V Belimo power to close / spring to open motor. The Belimo closes the ventilator once the fan has been switched off. For smoke control In a fire situation there is a double safety mechanism: If the smoke is cool then the fan will start up and the flap open as above. If the smoke is hot, then an additional failsafe device will open the FCO within seconds, without any intervention of the Belimo motor. 4.6 Product stats group W-LIBERATOR: B 02. 4.7 EN Classifications Requirements of EN 12101-3 Time-Temperature Class F200 200°/120Min Time-Temperature Class F300 300°/60Min Time-Temperature Class F400 400°/120Min Snowload Class SL 125 125 N/m² Snowload Class SL 250 250 N/m² Snowload Class SL 500 500 N/m² Powered Extract Unit with dual function of smoke and day to day extract Opening time for flap(s) Closing time for flap(s) T-Libera tor TL/3/... yes yes yes yes no no yes Immediate Immediate Yes = requirements fulfilled No = requirements not fulfilled Confidential © Colt International Licensing Ltd 2014 W -Libe ra tor W L/3/../FCO W L/3/../FLAP yes yes yes yes yes yes not applicable yes not applicable yes not applicable yes yes yes 16 sec. 150 sec. 22 sec. 22 sec. ! Issue 04 Group Product Technical Specification Page 5. 1 Date February 2014 G.P.T.S. N° 1105 W-Liberator TECHNICALINFORMATION 5.1 Dimensions WL/03/../W.. - WL/3/06/W/ WL/3/08/W/ FCO/0911 FCO/1013 Flap rear guard front guard 5.1.1 Dimensions and weights WL/3.. Size/type WL/3/06/W/... WL/3/08/W/... Size/type 06/W/FCO 08/W/FCO 06/W/Flap 08/W/Flap body width height A mm B mm C mm 684 844 480 627 766 926 flange body depth width height closed. open body inner flange flange outer flap body closed body open D mm E mm F mm G mm H mm J mm K mm L mm M mm N mm S mm T mm kg m³/ hmPa2/3 824 974 - 865 998 - 974 1124 - 1015 1148 - 220 220 270 270 - 680 840 920 1090 740 900 775 935 382 382 1053 1213 60 105 70 115 2.0 2.0 0.47 0.47 * a-value = air leakage Confidential weight a-value* © Colt International Licensing Ltd 2014 ! Issue 04 Group Product Technical Specification Page 5. 2 Date February 2014 G.P.T.S. N° 1105 W-Liberator TECHNICALINFORMATION 5.2 Dimensions WL/03/../R/Flap 5.2.1 Dimensions and weights WL/3.. Size/ type WL/3/06/R WL/3/08/R Size/ type 06/R/Flap 08/R/Flap Upstand Confidential © Colt International Licensing Ltd 2014 A mm B mm C mm 684 844 - 766 926 body inner flange upstand weight inner K mm L mm U mm kg 680 840 920 1090 700 860 70 115 ! Issue 04 Group Product Technical Specification Page 5. 3 Date February 2014 G.P.T.S. N° 1105 W-Liberator TECHNICALINFORMATION 5.3.1 Performance data WL/3 - 300°C / 60min (F300) Size WL/3/08.. 16 Airflow RPM Voltage Current Power m³/h m³/s min-1 Volt/Ph. A kW 22025 6.12 940 380-415/3 3.71 1.50 cos Wiring Average sound pressure level* dB(A) Motor EDP no. 73,5 354889 0.73 ABB Will be delivered with 2m breakout cable. Direct conecting to the motor is not possible. 5.3.2 Performance data WL/3 - 200°C / 120min or 400°C / 120min (F200 / F400) Size Airflow m³/h WL/3/06.. 13480 23 9185 16 WL/3/08.. 22025 16 RPM Voltage Current Power m³/s min-1 Volt/Ph. A kW 3.75 2.5 1420 915 380-420/3 380-420/3 3.19 1.97 1.50 0.75 6.12 940 380-420/3 3.78 1.50 cos Wiring Average sound pressure level* dB(A) Motor EDP no. Motor EDP no. ABB WEG 0.83 0.76 76.5 66.5 317935 317932 318948 318945 0.74 73.5 317933 318946 * Average sound pressure level measured at 3m distance in free field conditions. IP 55 rated, with insulation class H. Flap Technical data worm gear motor: Voltage : 400V; RPM : 23.0 Power : 0.09 Protection : IP 54 Insulation Class : F Current : 0.4 Confidential 3 Ph.; 50 Hz. min-1 kW FCO Technical data actuator: Type : BELIMO Voltage : 230 V AC Torque : 15 Protection : IP 44 Insulation Class : F A © Colt International Licensing Ltd 2014 AF230 50/60 Hz Nm ! Issue 04 Group Product Technical Specification Page 5. 4 Date February 2014 G.P.T.S. W-Liberator TECHNICALINFORMATION 5.4 N° 1105 Acoustic data WL/3 Measured without ducting. Sound power level (dB) Size WL/3/06.. 23 16 WL/3/08.. 16 5.5 63 125 Centre octave frequency (Hz) 250 500 1,000 2,000 4,000 8,000 Mean sound power level dB(A) inlet discharge inlet discharge 66.0 71.0 60.5 60.5 73.0 77.0 73.5 75.0 85.0 95.0 77.0 76.5 85.0 85.0 75.0 74.0 85.0 83.0 74.0 73.0 82.0 80.0 72.0 71.5 78.0 76.0 64.5 64.0 68.0 66.0 55.5 55.0 89.0 90.0 79.0 78.0 inlet discharge 69.0 69.0 83.0 84.5 84.5 87.5 84.0 84.0 83.0 81.5 81.0 78.5 76.5 74.5 66.0 63.5 88.0 87.0 Cabling technical data - Halogen free, not flammable, norm NF C 32-070 Non flammable (Norm IEC 332-1) Temperatures for continuous operation: -60°C to +400°C, max +500°C Cable type: MGL--NI/Fe (4x2,5mm²) The cable connecting to worm gear motor and limit switches is silicone 4x1.5, type SIHF-J* * See appendix for wiring diagram The cables provided with the product are not allowed to be used outdoors. Any contractor which lays the cable on cable trays or places it into the ceiling must be qualified to carry out such work. Confidential © Colt International Licensing Ltd 2014 ! Issue 04 Group Product Technical Specification Page 5. 5 Date February 2014 G.P.T.S. W-Liberator TECHNICALINFORMATION 5.6 N° 1105 Fan curve 06 size Type: WL/3/06/23/.. Value∑ ζ Statis pressure diference (Pa) WL/3/06/16/.. Air flow V (m³/s) 5.7 Fan curve 08 size Value∑ ζ Statis pressure diference (Pa) Type: Air flow V (m³/s) Confidential © Colt International Licensing Ltd 2014 WL/3/08/NF/16/.. ! Issue 04 Group Product Technical Specification Page 5. 6 Date February 2014 G.P.T.S. W-Liberator TECHNICALINFORMATION 5.8 N° 1105 Installation Installation onto fixing angles Inside of building fixing angle (by others) front guard rear guard Continuous aluminium angle section 50 x 50 x 5 Confidential © Colt International Licensing Ltd 2014 Fixing angle (by others)