Roncolli School Expansion - BF Kennedy Sound Systems
Transcription
Roncolli School Expansion - BF Kennedy Sound Systems
N. S. C. A. BF Kennedy Sound Systems Ltd. Main Highway - Roaches Line P.O. Box 191 - South River - Newfoundland Canada - A0A 3W0 email:[email protected] Tel: (709) 528-1360 www.bfksound.ca P roud M ember of the N ational Systems C ontractors A ssociation Fax: (709) 528-1182 Roncolli School Expansion 27 53 13 - Clock (Intercom & Program) System - Shop Drawings • MCS350 intercom system (with 48 circuits) • ACC5 administrative control console • TPU100 100 watt amplifier • RCD350P Tuner CD Mixer (c/w MP3 input) • Universal whip antenna • PD-D2610 5 Disc CD Player • WebSchedule PC Remote/Local Programming Software • Omnismart1500 1500VA UPS • PCSG-25-MP classroom station • EMT501B corridor/washroom speaker • ETBS T-Bar support • Drawing paging speaker mounting detail • E86CWT5SA gym (and wallmount) paging speaker • EBB8SF square speaker back-box • PTM-01C washroom pullcord station • EAM-10W volume control • VPCS-2GPB-2 Vestibule intercom station • WT-201A Wireless Pendant Transmitter • WR-200 Wireless Receiver • D225 Digital clock • CV-Guard-F Lexan cover (for gym clocks) • D2M-Corr-Kit double faced corridor clock • CV-Guard-F lexan guard for clock in gym • SR-12RD-2WS-03-SP Analog Clock • TC10024-1 clock power supply • 310-120 Bells c/w PVC box • GR-GFS4B2723TDB 27U floor rack • Drawing Updated IC/CLOCK Riser Sound, Communications and Security Systems for Education, Health Care and Industry MCS350 Series Communications Systems MODULAR COMMUNICATIONS SYSTEM Wall Mount Features • Advanced Microprocessor Design • Simultaneous Program Distribution and Two-Channel Intercom • Built-In and Remote Diagnostics • Selectable SingleQueue Operation • PC Interface for Remote System Programming • Twenty-Five Programmable Tone Types • User-Programmable Input Ports and Output Contacts • RS-485 Serial Port • User-Programmable, Battery-Backed Master Clock General Description The Dukane MCS350 Series is a multichannel, microprocessor-controlled, programmable administrative communications system that provides a range of audio communications functions. These functions are initiated from any one of up to four Administrative Control Consoles (ACCs) that can be connected to the system. The entire system of ACCs and up to 256 remote stations are controlled by a Dukane Model MCS350 Central Control Unit (CCU). Two-way open voice communications can be initiated from an ACC to any remote speaker station or to another ACC. Paging and program distribution can also be initiated by an ACC to any one station or group of remote stations. The built-in master clock can be programmed to control time tone distribution to any or all remote stations. The master clock can correct selected synchronous clocks or selected digital clocks. The clock has a battery backup to maintain the correct time for seven days after power loss. DUKANE CORPORATION | COMMUNICATIONS SYSTEMS DIVISION | 2900 DUKANE DRIVE | ST. CHARLES, ILLINOIS 60174 ISPA/MCS350/Telapex All specifications subject to change without notice. 427-01-00078 (03) (General Description) The MCS350 has three independent audio communications paths: one program channel and two open-voice intercom channels. All three channels can be active simultaneously, without interruption. The program channel is used for paging, time signaling, and program distribution to multiple remote stations. The two intercom channels allow two simultaneous intercom conversations: one between an ACC and a remote station, the other between two ACCs. Two simultaneous ACC-to-ACC conversations are also possible. Program channel communications need not interrupt remote station intercom use. The ACC is a desktop unit that initiates and displays all MCS350 functions. The ACC consists of a protective housing, a 31-key, color-coded, spillproof key pad, a 16-character alphanumeric LCD, a built-in microphone and speaker, and a two-way handset. ACC key pad entries are accompanied by both audio and visual feedback. The EMERGENCY, CUSTODIAN, PAGE, PROGRAM, CONSOLE, SYSTEM, and HOLD keys have accompanying LEDs to indicate the function status. The ACC also has speed dial, redial, manual time-tone generation, and program monitoring capabilities. ACC users have program channel access for zone paging to preselected groups of remote stations or for all call paging. Remote stations can be assigned to more than one zone. ACC users can also program the entire system by entering the user-assigned access code. The built-in programmable master clock allows 256 discrete time event entries. Each event is assigned to one, a combination of any five, or all eight time zones; one of eight time schedules; one of eight user-programmable tone types; and any combination of days of the week. The system master clock can be synchronized by an external master clock system. All system programming is stored in non-volatile (EEPROM) memory and is retained in the event of power failure. The 16-character LCD display keeps the user informed of current ACC status at all times. When no calls are in the system, the display shows the time of day in either 12or 24-hour format. As calls are received by the ACC, the display shows the two-, three-, or four-digit alphanumeric room number of the calling station as well as the call’s position in that ACC’s call-in queue. Each ACC has its own individual queue for storing incoming calls. These queues are user-programmable so that any room can be programmed to call into any one of the ACCs. All rooms can also be programmed to call into a single ACC. The ACC indicates each call it receives by sounding a call-in tone and updating its queue status display. Calls into an ACC are inserted into the queue first according to their priorities, then in order of arrival. Five call-in priority levels are user-programmable for each remote station: emergency, ACC call-in, high priority, staff, and normal. The system has 100 percent queuing of incoming calls so no calls can be lost. Incoming calls can be scanned using the DISPLAY CALLS key and can be answered in any order desired. An ACC can place a call with calls waiting in its queue. A single queue mode that places all incoming calls into a single common queue can be selected. This allows directing all incoming calls to all ACCs during limited staff operation. 2 MCS350 Modular Communications System For voice intercom or paging functions, the ACC is equipped with a handset, key pad, speaker, microphone, and a PUSH TO TALK key. The handset is engaged whenever it is in a non-horizontal position. Voice-activated switching (VOX) automatically switches audio direction. When the handset is not active, the direction of communication is controlled by the PUSH TO TALK key. The built-in microphone is active when the PUSH TO TALK key is pressed and the speaker is active when that key is released. (General Description) The system has user-programmable input ports that allow external devices to trigger time and emergency tones, external all call, door monitor, night transfer switch, and other system functions. User-programmable dry-contact outputs are provided to signal external devices when functions such as clock synchronization, all call, and remote annunciations occur. The system tone generator provides 25 tones. The volume level and duration of each tone is programmable. The MCS350 System includes off-hour door alert, a programmable alarm tone for sounding a door alarm in all or selected zones by the closure of a single switch contact. The Model MCS350 Central Control Unit consists of one digital card, one analog card, one or more SC16 or SCX16 Switching Cards, one 24Vdc power supply, and one or more 60-watt power amplifiers. A single switching card can handle up to 16 remote stations. The MCS350 can contain up to 16 switching cards, resulting in a system capacity of 256 remote stations. The MCS350 performs self-diagnostic tests for detection of various system errors or invalid keystroke sequences. If a system error is detected, a message is displayed on each ACC in the system. The MCS350 System has an RS-232 port for a PC or a Dukane SmartSystem® interface that allows menu-driven programming of system information (room numbers, zones, events), storing system programming on diskette, establishing a system directory of teacher names with room numbers, adding and deleting rooms from zones, logging and storing priority system activity, and retrieving data for review and printing. An RS-485 port provides for long distance serial communications with future equipment. The Dukane MCS350 is available in two models: a wall-mount version and floor rack version. The wall-mount version can accommodate up to four switching cards (64 remote stations), a 24Vdc power supply, and a 60-watt power amplifier. The floor rack version is an upright 19-inch (48.3 cm) rack unit that houses the Central Control Unit as well as an optional AM-FM tuner/cassette player (with or without preamp). The 19-slot card cage in the rack model can contain up to 16 switching cards (256 remote stations). The rack also houses the 24Vdc power supply, and up to six 60-watt power amplifiers. A single power amplifier is recommended for each set of 64 remote stations. MCS350T Administrative Communications System 3 RATED OUTPUT 25V line or 45Ω system PROGRAM: Wall cabinet: 60W (rms) Rack mount: 60W to 360W (rms) INTERCOM: 4W (rms) Specifications POWER REQUIRED MCS350 WALL CABINET: 105Vac to 132Vac @ 3A MCS350/R RACK: 105Vac to 132Vac @ 10A INPUTS External program source INPUT SENSITIVITY EXTERNAL PROGRAM SOURCE: 500mV nominal INTERCOM: 500mV nominal FREQUENCY RESPONSE PROGRAM: 50Hz to 15kHz INTERCOM: Voice-filtered for maximum intelligibility COMPRESSORS Automatic level control of both talk and listen DISTORTlON PROGRAM: Less than 2% at full load INTERCOM: Less than 2% at full load NOISE LEVELS EXTERNAL PROGRAM SOURCE: –60dB INTERCOM: –60dB OUTPUT REGULATION PROGRAM: Better than 2dB from no load to full load INTERCOM: Better than 2dB from no load to full load FUSES WALL CABINET POWER SUPPLY: AC—0.75A slow blow, DC—3A fast blow RACK MOUNT POWER SUPPLY: AC—1.25A slow blow, DC—5A fast blow 60W POWER AMPLIFIER: AC—1.25A slow blow, DC—5A fast blow CENTRAL CONTROL UNIT (MCS350) MAIN: 5A slow blow SWITCHING CARDS: 0.25A slow blow ACC: Four 0.25A slow blow EXTERNAL PROGRAM SOURCE: One 0.5A slow blow INTERFACES RS-232 port RS-485 port Clock correction Input port: Four input closures Output port: Two digital, two relay MCS350T Modular Communications System 5 (Specifications) TERMINATIONS EXTERNAL: “BIX” Telecommunication-type INTERNAL: “MAS-CON,” “LAT-CON,” “CHAMP” and screw terminal types DIMENSIONS MCS350 WALL CABINET: 21" (53.3 cm) wide x 28" (71.1 cm) high x 4-3/8" (11.1 cm) deep MCS350/R RACK: Standard 19" (48.3 cm) rack, 54" (137.2 cm) high x 21" (53.3 cm) wide x 17" (43.2 cm) deep NET WEIGHT MCS350 WALL CABINET: 47 to 50 pounds (21.2 to 22.5 kg) MCS350/R RACK: 139 to 228 pounds (62.6 to 102.6 kg) FINISH MCS350 WALL CABINET: 16-gauge steel backbox finished in matte gray baked epoxy MCS350/R RACK: Steel floor rack finished in charcoal black baked epoxy TONES Intercom Call-In Intercom Call-Out Privacy Page Preannounce Emergency Page Preannounce Civil Emergency Custodian Eight Time Tones Door Alert CONTROLS Full system control from any ACC ENVIRONMENTAL PARAMETERS 32° F (0° C) to 90° F (32° C), relative humidity 0 to 90% CAPACITY c/w 3 cards MCS350 WALL CABINET: Sixteen stations expandable to 64 stations One to four SC16 or SCX16 switching cards, 16 circuits per card Up to four Administrative Control Consoles (ACCs) One 60W power amplifier MCS350/R RACK: Sixteen stations expandable to 256 stations One to sixteen SC16 or SCX16 switching cards, 16 circuits per card Up to four Administrative Control Consoles (ACCs) Up to six 60W power amplifiers 6 MCS350 Administrative Communications System ACC5 Administrative Control Console Associated Equipment 9A1765 Call Switch (Pushbutton) PCS499 Call Switch, Three-Position Rocker PCSG3lWSE-25 Speaker Assembly (Flush) Square Baffle with Call-In Switch PCSB303SE-25 Speaker Assembly (Surface) with Call Switch PCS819 Dynamic Transmitter; Magnetic Receiver; 6' (1.8 m) Coiled Cord; for Two-Gang Backbox PCS822 Dynamic Transmitter; Magnetic Receiver; 6' (1.8 m) Coiled Cord; for Single-Gang Backbox PCS82l Dynamic Transmitter; Magnetic Receiver; 6 (1.8 m) Coiled Cord; Rocker Call-In Switch; for Single-Gang Backbox RTC350 AM-FM Tuner/Cassette Player (Rack Mount) RTC350P AM-FM Tuner/Cassette Player (Rack Mount) Including Preamp and Monitor Speaker TC350 AM-FM Tuner/Cassette Player (Desk Mount Cabinet) TC350P AM-FM Tuner/Cassette Player (Desk Mount Cabinet) Including Preamp and Monitor Speaker MCS350T Modular Communications System 7 Model ACC5 ADMINISTRATIVE CONTROL CENTER Features • 16-Character, Alphanumeric Liquid-Crystal Display • Built-In Speaker, Microphone, and Handset • Two-, Three-, or Four-Digit Alphanumeric Dialing • 12- or 24-Hour Clock Display • Menu-Assisted, User-Programmable Functions • Queues 100% of Remote Call-Ins • Color-Coded, Spill Protected Key Pad • Function Keys with ON/OFF LED Indicators • Call Forwarding and Transfer Capabilities • Call Priority Levels • Built-In Diagnostics • Off-Hook Handset Switch in Cradle General Description The Dukane Model ACC5 Administrative Control Console (ACC) is the control center for communication, paging, signaling, and programming for the Dukane MCS350 Series and MCS350T Series Administrative Communications Systems. The ACC incorporates a telephone handset, microphone, speaker, volume control, 16-character alphanumeric liquid crystal display (LCD), and key pad controls. The control panel allows the operator to establish two-way communications between an ACC and any remote station or another ACC. The operator can also answer incoming calls and selectively distribute external program sources to particular remote stations or zones. In addition, the ACC allows all-call or zone paging, separate emergency paging, and civil emergency tone distribution to all stations. A dedicated key provides a unique custodial call tone to all speakers. All ACCs in a system have identical functions and control features, yet each can be independently programmed to perform specific operations for particular secretarial or administrative needs. Functions such as alphanumeric architectural room numbering, call-in priority levels, and the 256-event, eight-schedule and eight-zone time clock are user programmable from the ACC control panel. The LCD provides menu-assisted prompting and instructions during system programming, and visual indication of regular and/or emergency incoming calls, paging zone selections, and room selections during routine operation. The system provides, as a minimum, simultaneous intercom to any speaker location, intercom between two ACCs, and program distribution to any combination of individual remote stations or zones. DUKANE CORPORATION | COMMUNICATIONS SYSTEMS DIVISION | 2900 DUKANE DRIVE | ST. CHARLES, ILLINOIS 60174 ISPA/MCS350/Telapex All specifications subject to change without notice. Document 427-01-00079 (04) (General Description) The ACC’s telephone-style housing is made of molded, high-impact plastic and consists of an alphanumeric LCD, speaker, microphone, handset, and touch-sensitive membrane key pad for call operations, paging, and program distribution. The control panel is organized in a logical, color-coded format to ensure ease of operation. Function key F5 is factory-configured for redial. All other function keys are user-configurable for speed dialing or other specific system operations. The large, 16-character LCD provides 100 percent queuing of calling room numbers, call priority, sequential display of calls waiting, current time in the idle state, menu assistance during system programming, and an operator dialing display. The ACC displays multiple calls by priority and order of call-in sequence on the LCD. A scrolling feature allows the operator to view pending calls and, if desired, answer a call out of sequence. Routine calls are audibly announced by a call-in tone and visually indicated by the appearance of the calling station’s number and call priority level. These calls can be answered using the handset or built-in microphone, placed on hold, transferred to another ACC, or terminated. Emergency and high priority calls are distinguished by a long, unique alert tone and flashing station number. These calls can be answered, placed on hold, and transferred to another ACC. During times of limited staff operation, calls can be temporarily forwarded to another ACC in the system. The ACC operator can place a call to any remote station in the system having audio capabilities. At the same time, two other ACC operators can be in communication with each other. Calls to remote speaker stations are made with a preannounce tone and generate discrete, intermittent privacy tones to remind the receiving party that the lines of communication are open. The ACC allows automatic one-button redialing of the last number dialed by pressing the F5 function key. It also provides four additional function keys with nine function locations (F1–F4 and F6–F10 using SHIFT key) for speed dialing frequently called numbers. The ACC operator can page up to five zones selectively or all eight zones in the system. The all page feature disregards zone assignments and allows paging to all remote stations. In addition to conventional paging, the ACC operator can generate an emergency tone with a page, and civil emergency and custodial tones without pages. The ACC operator can program the system clock for automatic time tone distribution. A maximum of 256 events and eight schedules are available. Authorized ACC operators can alter the parameters of a programmed event at any time. Time tones can also be distributed manually by an ACC operator, in addition to the automatic time tones. The ACC provides the means for system programming and initialization. Call-point designations, call-in priorities, zones for paging, time tone distribution, and program event schedules are user-programmable features that can be altered by authorized personnel as facility needs change. System programming is protected by a user-assigned access code. 2 ACC5 Administrative Control Center Product Data Sheet Audio programming can be distributed manually by the ACC operator to any combination of up to eight zones in the system, with monitoring at the ACC any time before and during the distribution of the program. (General Description) OUTPUT Telephone line level Specifications SPEAKER 2.5" (6.4 cm), 8Ω, 3W MICROPHONE Built-in condenser type HANDSET AND CORD Electret transmitter Dynamic receiver Grey, flame-retardant, high-impact plastic with 3' (0.9 m) plug-in modular cord set CONTROLS (KEY PAD) Speaker VOL with plus or minus volume displayed on LCD EMERGENCY key with LED on/off indication PAGE key with LED on/off indication PROGRAM key with LED on/off indication CUSTODIAN key with LED on/off indication DISPLAY CALLS key HOLD key with LED on/off indication PUSH TO TALK key CANCEL key ENTER key CONSOLE programming with LED on/off indication SYSTEM programming with LED on/off indication NEXT SELECT EXIT KEY PAD 0 through 9 (A through J using Shift key) SPECIAL FUNCTION KEYS F1 through F4 (F5 is factory programmed as redial key; access F6 through F10 using Shift key) POWER REQUIREMENTS 24Vdc obtained through connection to MCS350 or MCS350T DATA SIGNAL REQUIREMENTS 7,800 baud between ACC and central processor ACC5 Administrative Control Center Product Data Sheet 3 (Specifications) DISPLAY Large 16-character LCD alphanumeric readout TONES User-programmable time, alarm, and call-in tones SWITCHES/KEY PAD Sealed, spill protected polycarbonate membrane FUNCTIONS ACC-to-speaker page ACC-to-speaker/microphone intercom ACC-to-ACC intercom Queuing of incoming calls (100%) Sequential displays of calls queued Call hold Call forwarding Sequential display of priority stations Display of current time in idle state Full display of programmer prompting Full display of operator function dialing LEDs indicate function keys on/off Audio program distribution control Zone page All call page TERMINATIONS Standard 8-wire locking plug-in telephone connector HOUSING High-impact, flame-retardant, grey plastic DIMENSIONS 9.5" (24 cm) wide by 4" (10.2 cm) high by 8.75" (22.2 cm) deep (dimensions include handset) NET WEIGHT 3 lb, 10 oz (1.63 kg) including handset Associated Equipment Model MCS350 Administrative Communications System Model MCS350T Administrative Communications System with Telephone Integration Model SC16 Four Wire Switching Card (expander), 16-circuit Model SCX16 Two Wire Switching Card Model 9A1765 Call-In Switch (pushbutton) 4 ACC5 Administrative Control Center Product Data Sheet Telephone Paging Amplifiers Models TPU35B,TPU60B, TPU100B & TPU250 Description Bogen models TPU35B,TPU60B,TPU100B, and TPU250 are wall-mounted telephone paging amplifiers rated at 35, 60, 100, and 250 watts, respectively. The TPU250 can also be rack-mounted.This group of TPU amplifiers permits paging from telephone and/or microphone. Music input through an RCA jack or screw terminals.Voice-activated, variable level, music mute with fade back after page. All the TPU amps in this group include a night ringer which sends an electronic ringing tone signal through all speakers, alerting personnel of incoming calls during non-business hours. Jacks are also provided to bridge two TPU amplifiers to double the number of inputs and outputs. Features • 35, 60, 100, and 250-watt models • Bass and treble controls • Inputs for 600-ohm balanced telephone line, LO-Z balanced microphone, and background music • Built-in night ringer activated by contact closure or by 90V ring signal • Music input (RCA jack or screw terminals) • Balanced or unbalanced 16-ohm, 25V, 25VCT, and 70V outputs are available for the TPU35B/60B/100B models; 25V and 70V outputs are available on the TPU250 • Integral automatic level control (ALC) circuit for controlling pages made by persons with varying voice levels and paging techniques • VOX sensitivity level control eliminates transmission of background noise when paging from a telephone • Page from telephone and/or microphone • Thermal and electronic overload protection • Signal-activated paging channel automatically mutes background music • Adjustable background music muting level during a page • Jacks provided for bridging additional TPU amplifiers • Brackets are attached for easy wall mounting;TPU250 can be rack-mounted • Music gradually returns to its normal level after a page • TPU-B models can be rack-mounted with RPK82 kit • Aphex® Aural Exciter increases intelligibility, improves perceived loudness (with no increase in power), and reduces listener fatigue • Separate controls for page volume, music volume, night ringer, music mute, and Aphex® Aural Exciter • Peak level indicator lights when amplifier is driven into clipping • 120V AC, 60Hz power source • UL and CSA listed Specifications subject to change without notice. © 2000 Bogen Communications, Inc. Part No. 54-7836-02R3 Printed in U.S.A. 0101 Aphex® is a registered trademark of Aphex Systems, Ltd. Technical Specifications Power Output: Frequency Response: Distortion: Hum & Noise: Sensitivity: Tone Control: Regulation: Inputs: Outputs: Controls & Indicators: Overload Protection: Power Requirements: Operating Temperature: Finish: Dimensions: Shipping Weight: TPU35B: 35W RMS; TPU60B: 60W RMS; TPU100B: 100W RMS; TPU250: 250W RMS 70Hz to 15kHz ±1dB Less than 1% (20Hz to 20kHz) MUSIC: -70dB; TEL: -70dB; MIC: -55dB MUSIC: 85mV; TEL: -20dBm (77mV); MIC: 600µV BASS: ±9dB @ 100Hz; TREBLE: ±9dB @ 10kHz 2dB TEL: 600-ohm balanced line, transformer-isolated MUSIC: Hi-Z source, RCA jacks or screw terminals MIC: LO-Z balanced, screw terminal connection MUSIC MUTE: Mutes music during a microphone page CONTACT RING: Sounds night ringer tone when customer-supplied dry contacts are closed TEL RING: Sounds night ringer in response to 90V ring signal BRIDGING: Permits bridging of two amplifiers 25V, 25VCT, and 70V, 16 ohms balanced or unbalanced for 35/60/100-watt models; 25V and 70V for TPU250. Provision for WMT1A line-matching transformer POWER & PEAK LEVEL LED indicators. APHEX,TREBLE, BASS,VOX SENS, RINGER VOLUME, MUSIC MUTE, MUSIC VOLUME, MIC VOLUME, TEL VOLUME, ALC controls (screwdriver-adjustable) All models have thermal and electronic overload protection. TPU35B: 1.0A, 120V AC circuit breaker; TPU60B: 1.6A, 120V AC circuit breaker; TPU100B: 2.5A, 120V AC circuit breaker; TPU250: 6.0A slow blo fuse (120V AC, 60Hz) TPU35B: 0.75A; TPU60B: 1.5A; TPU100B: 2A; TPU250: 5A -4°F (-20°C) to 131°F (+55°C) Black with silver lettering TPU35/60/100B models: 14-3/16" W x 8-3/8" H x 3-5/8" D TPU250: 19" W x 10-1/2" H x 3-13/16" D TPU35B: 16 lbs.; TPU60B: 17 lbs.; TPU100B: 21 lbs.; TPU250: 31 lbs. Architects The telephone paging amplifier shall be a Bogen Model ___, and Engineers with a full power rating of ___ watts. (Specify: TPU35B/35 Specifications watts, TPU60B/60 watts, TPU100B/100 watts, TPU250/250 watts.) The amplifier shall provide a frequency response of ±1dB from 70Hz to 15kHz, and shall deliver rated power at less than 1% distortion. The amplifier shall permit paging from telephone and/or microphone. The signal-activated paging channel shall automatically mute background music during a telephone page, eliminating the need for manual activation of switches and the use of external relays. Provision shall be included to set to mute the level of background music during a page. Music level shall be returned to its normal level after a page. The telephone paging channel shall have a VOX sensitivity adjustment to eliminate transmission of background noise, and automatic output leveling (ALC) to compensate for varying voice levels and paging techniques of persons using the system. An Aphex® Aural Exciter circuit shall be included to regenerate the harmonics lost during the amplification process. A control shall be provided to set the level of the Aphex effect. A night ringer shall be included to alert personnel of incoming calls during non-business hours. The night ringer shall be activated by a contact closure or by 90-volt ring signal from the telephone line. Input terminals shall be furnished for a telephone line and LO-Z balanced microphone. A choice of RCA jack or screw terminals shall be provided for the music source. Terminals shall also be provided to control music muting during a mic page, and for contact closure or ring signal activation of the night ringer. Bridging jacks shall be provided to bridge two TPU-series amplifiers. Balanced or unbalanced outputs shall be provided for 16ohm, 25V, 25VCT, and 70V speaker lines. Provision shall be included to feed a 600-ohm telephone line, LO-Z input or balanced microphone input of another amplifier, using an accessory line-matching transformer (Model WMT1A). Individual controls shall be provided to set the telephone and mic page volume, music volume, night ringer volume, VOX sensitivity, and music mute level. Bass and treble controls shall permit tonal adjustments. An automatic level control (ALC) and VOX sensitivity controls shall be included. A peak level indicator shall illuminate when the amplifier is driven into clipping. A power indicator shall also be provided. The amplifier shall operate from a 120V AC, 60Hz source, and shall be equipped with a resettable circuit breaker and thermal and electronic overload protection (TPU250 has a 6A slow-blo fuse). Installation shall be facilitated by flanges with keyhole slots for mounting on a suitable backboard. Dimensions for the 35, 60, and 100 models shall be 14-3/16" W x 8-3/8" H x 3-5/8" D. Dimensions for the TPU250 shall be 19" W x 10-1/2" H x 313/16” D. 50 Spring Street, Ramsey, New Jersey 07446 201-934-8500 FAX: 201-934-9832, www.bogen.com Dukane Catalog u Commercial Sound Products AM-FM Tuner/CD & MP3 Player with Mixer/PreAmp RCD350P Overview Standard Features Dukane AM-FM Tuner/CD and MP3 Player with Mixer/PreAmp is an auxiliary music and sound source for paging and intercom systems. It can be installed in a standard 19 inch rack or as a desktop unit by removing the rack mounting hardware. CD Player • Supports most common CD audio formats: including CD, MP3 and WMA Application • Three-band equalizer with six preset tone curves Designed for use with Dukane StarCall and MCS350 Administrative Communications Systems, these units provide a single channel output from one or all five inputs. A mixer/preamp section selects and/or mixes up to four external inputs and one internal source. The preamp section is equipped with a master gain control and output level LED indicator. A monitor speaker and volume level control are provided for input selection, cueing, and level adjustment. A master on/off switch with indicator controls unit power. A priority enable circuit allows giving one input priority over all others. A bridging circuit is provided to increase the number of available program sources. Both models combine a sensitive AM-FM tuner with a CD player. Player includes input jack for MP3 player interface. Page 1 of 2 • Aux stereo input jack (3.5 mm) allows for playback of MP3 devices and their pre-recorded music or announcements • Single line text LCD display with 8-character text • MP3 ID3 Tag Display (Title, Artist, Album)- shows tuner band, elapsed playback time, track number, type of disc, (when repeat play and local seek tuning are activated) - displays time when not in use • Remote control for tuner included Mixer/Preamp Unit • Priority enable circuit • Two low Z microphone inputs • Two AUX inputs • One bridge input 85100-0141 D ATA S H E E T Not to be used for installation purposes. Issue 1 Specifications Tuners AM Tuner Detection & alarm since 1872 FM Tuner U.S. T 800-385-2639 Canada T 519-748-5352 F 519-748-9221 utcfireandsecurity.com © 2010 UTC Fire & Security. All rights reserved. CD Player WMA (.wma) WAV (.wav) MP3 (.mp3) Disc Frequency range selectivity: 530kHz to 1710kHz 40dB (+/–10kHz) Maximum sensitivity: 14dB/mV (5mV at 0.5W) Frequency range alternate channel selectivity: 87.9MHz to 107.9MHz 75dB Usable sensitivity stereo separation: 15.2dBf (1.6mV, 75W) 35dB at 1,000Hz 50dB quieting sensitivity image response ratio: 17.2dBf (2.0mV, 75W) 50dB Frequency response if response ratio: +/– 3dB 30Hz–15,000Hz 100dB Capture ratio signal-to-noise ratio: 1.5dB 70dB Encoded by Window Media Player Bit rate: 48 Kbps to 320 kbps (CBR), 48 kbps to 384 kbps (VBR) Compatible format: Linear PMC (LPCM). MS ADPCM Quantization bits: 8 and 16 (LPCM), 4 (MS ADPCM) Sampling frequency: 16 kHZto 48 kHZ (LPCM), 22.05 kHz and 44.1 kHz (MS ADPCM) Bit rate 8 kbps to 320 kbps Sampling frequency: 16 kHz to 48 kHz (32,44,1,48 kHz for emphasis) Compatible ID3 tag version: 1.0, 1.1, 2.2, 2.3, 2.4 (ID3 Tag Version 2.x is given priority over Version 1.x; M3u playlist: No; MP3i (MP3 interactive), mp3 PRO: No Playable folder hierarchy: up to eight tiers (A practical hierarchy is less than two tiers) Playable folders: up to 99; Playable files: up to 999 File systems: ISO 9660 Level 1 and 2, Romeo, Joliet Multi-session playback: Yes; Packet write data transfer: No; Regardless of the length of blank section between the songs of the original recording, compressed audio discs play with a short pause between songs. Overall Data Power requirements +12Vdc, 700mA maximum Inputs 2 low-impedance microphones, 2 auxiliary inputs, built-in AM/FM/CD/MP3 Player Audio line output 3Vrms maximum Controls (front) POWER on/off switch, MASTER volume control, MONITOR speaker volume, control, 5 source selector/mixer bank Controls Function, EQ/Loud, SCR/Off, Station Program Buttons (6). Eject (CD), Audio, (AM-FM tuner/ Clock set, Disp/SCRL, Band/ESC, Curser ControlScan; Tuning (manual or CD Player) preset, five AM and ten FM preset stations available) Controls (rear) 5 source preset input level adjustments, 1 monitor preset level adjustments, 1 bar graph level adjustment Indicators/displays Master Power LED; Preamp output level bar graph Terminations Preamp out (screw terminal); Power (screw terminal); AUX (RCA pin jack); MIC input (screw terminal); Bridge (RCA pin jack); Priority Enable Input and Output (screw terminal); Antenna (F-81C female for RG59 coaxial cable, 75W) Housing Metal rack mount panel finished in textured charcoal-colored powdercoat. Can be converted to tabletop. Dimensions 19" (48.3 cm) wide x 3.5" (8.9 cm) high x 10.25" (26 cm) deep When used as a table top configuration, the dimensions are: 14" (36 cm) wide x 2.75" (7 cm) high x 10.25" (26 cm) deep Antenna termination F-81C female for RG59 coax cable 75 Ω Wiring Preamp out Twisted pair, 22 AWG min. Ordering Information Model RCD350P RCD-RA RCD-PS Weight 11.7 lb (5.3 kg) 85100-0141 D ATA S H E E T Not to be used for installation purposes. Issue 1 10-06-10 Page 2 of 2 Description Rack mount AM/FM Tuner/CD Player and MP3 Player with pre amp, Includes RCD-PS Power Supply. Replacement rackmount adapter kit Replacement +12V power supply Universal Whip Antenna BFK NTS 07-Univ-Antenna 2007-06-01 9A10506200 Z PD-D2610 FRANÇAIS OWNER’S MANUAL MANUEL DU PROPRIÉTAIRE MANUAL DEL USUARIO ENGLISH Compact Disc Changer ESPAÑOL Name and Function B A K J C I H G F D E A POWER Press this button to turn the unit on or off. K L The equipment draws nominal non-operating power from the AC outlet with its POWER switch in the OFF position. O D P B Disc tray Q C OPEN/CLOSE R M N G F T S U E Use this button to open and close the disc tray. D DISC SKIP Use this button to skip discs. E PLAY (y) Use this button to start playback. F PAUSE (J) Use this button to pause playback. G STOP (H) Use this button to stop playback. H Skip/Search buttons Use these buttons to skip or search tracks. I Display J Remote Sensor When operating the remote control unit, point it towards the remote sensor. 6 Remote Control Unit K DISC NO. Use these buttons to slect a disc. L TRACK NO. Use these buttons to select a track number. For instance, to select track number 35, press “3” and “5”. M PROGRAM Use this button to enter the program mode. In program mode, use this button to enter selections. N SEARCH (m/,) During playback, use these buttons to search the part you want to listen to. < Even if the remote control unit is operated within the effective range, remote control operation may be impossible if there are any obstacles between the unit and the remote control. < If the remote control unit is operated near other appliances which generate infrared rays, or if other remote control devices using infrared rays are used near the unit, it may operate incorrectly. Conversely, the other appliances may operate incorrectly. ENGLISH O SHUFFLE The provided Remote Control Unit allows the unit to be operated from a distance. When operating the remote control unit, point it towards the REMOTE SENSOR on the front panel of the unit. Battery Installation Use this button for shuffle playback. P TIME During playback, use this button to change the time display. Q REPEAT Use this button to select repeat modes. R INTRO CHECK Use this button to start the intro check playing. 1. Remove the battery compartment cover. S PROGRAM CHECK Use this button to check programed contents. T CLEAR Use this button to clear a program. 2. Insert two “AA” dry batteries. Make sure that the batteries are inserted with their positive “+” and negative “_” poles positioned correctly. 3. Close the cover. U SKIP (.//) Use these buttons to skip tracks. Battery Replacement If the distance required between the remote control unit and main unit decreases, the batteries are exhausted. In this case replace the batteries with new ones. Precautions concerning batteries < Be sure to insert the batteries with correct positive “+” and negative “_” polarities. < Use batteries of the same type. Never use different types of batteries together. < Rechargeable and non-rechargeable batteries can be used. Refer to the precautions on their labels. < When the remote control unit is not to be used for a long time (more than a month), remove the batteries from the remote control unit to prevent them from leaking. If they leak, wipe away the liquid inside the battery compartment and replace the batteries with new ones. < Do not heat or disassemble batteries and never dispose of old batteries by throwing them in a fire. 7 Troubleshooting Specifications If you experience any problems with the unit, please take a moment to look through this chart and see if you can solve the problem yourself before you call your dealer or a TEAC service center. CD Player Pickup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-beam laser D/A converter . . . . . . . . . . . . . . . . . . . . . . . . Dual 1-bit linear Digital filter . . . . . . . . . . . . . . . . . . . . . . 4-times oversampling Frequency Response . . . . . . . . . . . . . . . 20 Hz - 20 kHz, ±2dB Total Harmonic Distortion . . . . . . . . Less than 0.02 % (1 kHz) Signal-to-Noise Ratio (S/N) . . . . . . . . . . . . . More than 100 dB Channel separation . . . . . . . . . . . . . More than 85 dB (1 kHz) Output . . . . . . . . . . . . . . . . . . . . . . . Analog: 2.1 Vrms (RCA) Digital: COAXIAL/TOS OPTICAL General No power e Check the connection to the AC power supply. Check and make sure the AC source is not a switched outlet and that, if it is, the switch is turned on. Make sure there is power to the AC outlet by plugging another item such as a lamp or fan. Cannot play. e Load a disc with the playback side facing down. e If the disc is dirty, clean the surface of the disc. e A blank disc has been loaded. Load a prerecorded disc. e Depending on the disc, etc. it may not be possible to play back CD-R/CD-RW discs. Try again with another disc. e You cannot play back unfinalized CD-R/CD-RW discs. Finalize such a disc in a CD recorder and try again. Sound skips. e Place the unit on a stable place to avoid vibration and shock. e If the disc is dirty, clean the surface of the disc. e Don’t use scratched, damaged or warped discs. Remote Control Unit Remote control doesn’t work. e If the batteries are exhausted, change the batteries. e Use remote control unit within an effective range (5m) and point at the front panel. e Clear obstacles between the remote control unit and the main unit. e If a fluorescent light is near the unit, turn it off. ENGLISH No sound e Check the connection to the amplifier. e Check the operation of the amplifier. General Power Requirement . . . . . AC 230 V, 50 Hz (European Model) AC 120 V, 60 Hz (U.S.A./Canada Model) Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 W Dimensions (W x H x D) . . . . . . . . . . . . . 435 x 115 x 390 mm (17 1/8” x 4 1/2” x 15 3/8”) Weight (Net) . . . . . . . . . . . . . . . . . . . . . . 6.2 kg (13 11/16 lb) Operating temperature. . . . . . . . . . . . . . . . . . . . +5˚C - +35˚C Operating humidity . . . . . . . . . 5% to 85% (no condensation) Storage temperature. . . . . . . . . . . . . . . . . . . . . –20˚C - +55˚C Standard Accessory . . . . . . . . . . . . . . . . . . . . . . RCA cable x 1 Remote control unit (RC-1122) x 1 Batteries (AA) x 2 Owner’s manual x 1 Warranty card x 1 • Design and specifications are subject to change without notice. • Weight and dimensions are approximate. • Illustrations may differ slightly from production models. For European customers Disposal of your old appliance MP3 There is no sound even if the PLAY button (y) is pressed. e Non-playable file formats cannot be played. Some unknown characters are displayed on the display panel. e This unit cannot display symbols and full-size or doublebyte characters (such as Japanese, Chinese, etc.) correctly. File name of MP3 should be alphanumeric characters. If normal operation cannot be recovered, unplug the power cord from the outlet and plug it again. 1. When this crossed-out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002/96/EC. 2. All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. 3. The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health. 4. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. 15 WebSchedule Network Based Scheduling Solution What is WebSchedule? • PC Window Application Software: • Schedules for events or bells. Allows update, change, create schedules. Runs on LAN Web Manager for Multi-Facility: Web Browser based to access scheduler. Allows update, change, create schedules. Interface over the WAN WebSchedule Systems Supported? • • • StarCall MCS350 Various others (contact your dealer for more info) WebSchedule Secured Web Schedule Application Secured Web Schedule Application Web Schedule Application running on local Windows PC WAN Web Schdule Application running on local Windows PC Web Schdule Application running on local Windows PC LAN Event Relays NETRLY4 Time Sync Relay What features and benefits it provides? • • • • • • • • • User does not need to know how to program system via installer software to create or modify bell schedules. Multiple Bell schedules: Standard, Special, Holidays etc. Easy to create and manage one schedule across multiple systems Calendar based, allows you view or edit on fly. Easy to use Supports over 200 events/bells. By date, day of week and time of day Support and Access over LAN/WAN Remote schedule set up and management WebSchedule Edit Page Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: OMNIVS1500XL OmniVS Series 1500VA Tower Line-Interactive 120V UPS with USB port and Extended-run options Highlights 1500VA / 1.5kVA line interactive, tower UPS with extended runtime capability Maintains 120V nominal output over an input range of 75V to 147V Workstation optimized features include USB port, single line TEL / DSL or Ethernet line surge suppression and two surge-only outlets Input: NEMA 5-15P (120V 15A) / Output: 8 NEMA 5-15R (120V) $200,000 Ultimate Lifetime Insurance (USA, Puerto Rico & Canada only) 3 year product warranty Description Tripp Lite's OMNIVS1500XL line interactive UPS system offers voltage regulation, surge suppression and long lasting, expandable battery support for personal computers, internetworking equipment and other sensitive electronics. Internal UPS batteries support entry level PC systems for up to 75 minutes during power failures so that connected equipment can be shut down without data loss. Automatic Voltage Regulation (AVR) circuits regulate brownouts as low as 75 and overvoltages up to 147 volts back to usable 120V levels without using battery power. Offers complete desktop power protection in an attractive black tower configuration. Includes 6 battery supported outlets for computer, monitor and vital system peripherals, plus 2 additional surge suppression only outlets for printers and other system accessories not requiring battery support. USB port enables optional unattended system shutdown without data loss in the case of extended power failure (USB cable included). PowerAlert software available via free download from www.tripplite.com. Built-in data line suppression offers protection for equipment with single line TEL/DSL or network Ethernet connection. Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and overload. 1500VA power handling ability supports entry-level PCs, network workstations, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems. Offers 4.5 minutes battery runtime with a full load of 1500VA and 13 minutes with a half load of 750VA. Supports hot-swappable battery replacement via built-in access panel. Extended runtime available with optional BP24V15RT2U, BP24V28-2U, or BP24V70-3U external battery packs. Package Includes OMNIVS1500XL Line Interactive UPS USB and telephone cable Owner's manual with warranty information Features OMNIVS1500XL Uninterruptible Power Supply offers voltage regulation, surge suppression and long lasting battery support Supports entry level PCs up to 75 minutes during blackouts to enable shutdown without data loss Regulates brownouts as low as 75V and overvoltages to 147V back to usable 120V nominal levels without using battery power 6 UPS battery supported outlets, plus 2 additional surge suppression-only outlets USB port and cable enables UPS monitoring and unattended shutdown in the case of extended power failure PowerAlert software available via free download from www.tripplite.com Data line surge suppression protects standard dialup/DSL or Ethernet line connection Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and overload 1500VA power handling ability supports a variety of sensitive electronic equipment 4.5 minutes full load runtime (1500VA), 13 minutes half load runtime (750VA) Runtime is expandable with the addition of external battery packs (SEE OPTIONS & ACCESSORIES) Supports hot swappable battery replacement via built-in access panel $200,000 connected equipment insurance (USA, Puerto Rico & Canada Only) 3 year warranty Specifications OUTPUT Output Volt Amp Capacity (VA) 1500 Output kVA capacity (kVA) 1.5 Output Watt Capacity (watts) 940 Nominal Output Voltage(s) Supported 115V; 120V Frequency compatibility 60 Hz Output voltage regulation (line mode) -18%, +8% Output voltage regulation (Battery mode) 115V (+/- 5%) Built-in UPS output receptacles 8 5-15R outlet(s) Surge suppression only outlets 6 UPS outlets, 2 surge-only outlets Basic PDU options PDU1215 (1U / 13 5-15R outlets); PDUNV (1U / 2 C19, 12 C13 outlets); PDU1415 (0U / 14 5-15R outlets); PDUV15 (0U / 12 5-15R outlets) Metered PDU options PDUMH15 (1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*; PDUMV15 (0U / 16 5-15R outlets) Switched PDU options PDUMH15ATNET (1U / 8 5-15R outlets)*; PDUMV15NET (0U / 16 5-15R outlets) External PDU redundancy options *Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS models only Output AC waveform (AC mode) Sine wave Output AC waveform (battery mode) PWM sine wave INPUT Rated input current (at maximum load) 12A Nominal Input Voltage(s) Supported 120V AC UPS input connection type 5-15P UPS Input cord length (ft.) 6 UPS Input cord length (m) 1.8 Recommended Electrical Service 15A 120V BATTERY Full load runtime (minutes) 4.5 min. (940w) Half load runtime (minutes) 13 min. (470w) Expandable battery runtime Extended runtime supported via optional external battery packs External battery pack compatibility BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) DC system voltage (VDC) 24 Battery recharge rate (included batteries) Less than 4.5 hours from 10% to 90% Replacement battery cartridge (internal UPS battery replacement) RBC51 (quantity 2) Battery Access Battery access door Battery replacement description Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage regulation description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 Overvoltage correction Input voltages between 128 and 147 are reduced by 12% Undervoltage correction Input voltages between 93 and 107 are boosted by 14% Severe undervoltage correction Input voltages between 75 and 92 are boosted by 30% LEDS ALARMS & SWITCHES LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status Alarms Audible alarm indicates power-failure and low-battery conditions Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Switches 2 Switches control off/on power status and alarm-cancel/self-test operation SURGE / NOISE SUPPRESSION UPS AC suppression joule rating 690 UPS AC suppression response time Instantaneous UPS Dataline suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC noise suppression Yes PHYSICAL Installation form factors supported with included accessories Tower Installation form factors supported with optional accessories Wallmount (UPSWM - tower mounting kit) Primary form factor Tower UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 11.8 x 7.2 x 7.5 UPS / Power Module dimensions in primary form factor (height x width x depth / cm) 29.8 x 18.4 x 19 UPS / Power Module weight (lbs) 28 UPS / Power Module weight (kg) 12.7 UPS Shipping dimensions (height x width x depth / inches) 15.5 x 11 x 11.2 UPS Shipping dimensions (height x width x depth / cm) 39.4 x 27.9 x 28.6 Shipping weight (lbs) 30 Shipping weight (kg) 13.6 UPS housing material Polycarbonate Cooling method Fan ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC mode BTU / hr. (full load) 355.1 Battery mode BTU / hr. (full load) 477.6 COMMUNICATIONS Communications interface USB PowerAlert software Free download from www.tripplite.com Communications cable USB cable included WatchDog compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer time 2-4 milliseconds Low voltage transfer to battery power (setpoint) 75 High voltage transfer to battery power (setpoint) 147 SPECIAL FEATURES Cold Start (startup in battery mode during a power failure) Cold-start operation supported High availability UPS features Hot swappable batteries CERTIFICATIONS UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) WARRANTY Product Warranty Period (U.S., Canada & Puerto Rico) 3-year limited warranty Connected Equipment Insurance (U.S., Canada & Puerto Rico) $200,000 Ultimate Lifetime Insurance Related Items Optional Products Product Type Related Model Description Qty. USB Hubs/Accessories U022-010 10-ft. USB2.0 A/B Gold Device Cable (A Male to B Male) - Wallmount Bracket UPSWM Wallmount Bracket and installation accessories (4 washers, 4 screws, 1 Velcro safety strap) - Software WATCHDOGSW WatchDog Service Monitoring / Reboot Software - Surge Protectors DTEL2 Network Surge Suppressor - Essential protection for data and communication lines - Surge Protectors DNET1 Network Surge Suppressor - Essential protection for data and communication lines - Extended Warranties WEXT5-OMNI 5-Year Extended Warranty - For OmniSmart, OmniPro, OmniVS - External Battery Packs BP24V15RT2U BP24V15RT2U - External Battery Pack for UPS System - External Battery Packs BP24V28-2U BP24V28-2U - External Battery Pack for UPS System - External Battery Packs BP24V70-3U BP24V70-3U - External Battery Pack for UPS System - More information, including related products, owner's manuals, and additional technical specifications, can be found online at www.tripplite.com/en/products/model.cfm?txtModelID=2730. Copyright © 2011 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products. Sound & Paging Equipment CALL STATION PCGS-25-MP FLUSH MOUNTING TYPE FEATURES: C Baked Epoxy Finish, Bone White C Heavy Gauge Steel Construction C Hidden Speaker Mounting Studs C Excellent Vandal Resistance DIMENSIONS: SPEAKER SPECIFICATIONS: C 12 ½" Square, 1 ½” deep , 11" mounting Centres. Fits Standard MC20E Back Box. C 8" Diameter C 6 oz Magnet Weight MCS - Call Switch C 60-14kHz Frequency Response C Momentary C 1" Voice Coil Diameter C Normally Open C Impedance - 8 Ohms C Pigtail Leads C Sensitivity (1W/ 1M)93dB C 10 Watts/RMS C Depth 2 3/4" PRIVACY C Clearly Annunciates System, Supplied Privacy Tone EMT501 & EMT501B Ceiling Speakers Corridor Speakers Key Features: u 5.5 inch woofer u Power selector terminal on rear u Snap in mount for easy installation u Modern design u All metal construction u Optional Supports u Optional HA501 Hole Saw Description The EMT501and EMT501B ceiling speaker is designed to meet the needs for background music and paging. The EMT501 & EMT501B incorporates a 5.5 inch speaker to ensure smooth, clear response. The EMT501and EMT501B is all metal construction to ensure maximum durability. Power is chosen using the convenient screw terminal on the rear. The spring loaded mounting clips guarantee fast and simple installation. Using the optional HA501 Hole Saw, it will cut installation time to an absolute minimum. This simple yet effective approach to background music and paging system speakers saves both time and money providing a very astatically pleasing look which appeals to even the most discerning of designer. Specifications Type : EMT Series Ceiling Speaker Driver : 5.5 full range Power Taps (25/70 V) : 4w, 2w, 1w, 0.5w Power Handling Direct : 15 watts Sensitivity (1W/1M) : 87 dB Frequency Range : 50/20kHz Rated Voltage : 70 volts, 25 volts, 8 ohm Dimensions (dia x depth) EMT 501: 7.875 200 x 75mm (7.875 inches x 2.75 inches) Dimensions (dia x depth) EMT 501B : 200 x 75mm (7.875 inches x 3.78 inches) 6.5 Cut out mounting diameter : 3.78 165mm (6.5 inches) Finish : White paint on metal 2.75 EMT 501 EMT501/B EMT 501B white radio a cygnal technologies company EMT501 & EMT501B Ceiling Speakers Polar Curves EMT501: EMT501B: Frequency Response EMT501: EMT501B: Optional Supports EMTBS T-Bar Support white radio a cygnal technologies company EDR501 Dry Wall Rough-in ESR501 Dry Wall Support Ring EMT501/B T-Bar Supports ETBS ETBS 24" T-bar supports can be used on their own or with any standard back box to provide tile support for speaker baffles installed in drop ceiling tile. ETBST T-Bar support 24" length for use with torsion mount baffles when not using a back box. Tile Bridge ETBST ETBSU ETBSU The universal tile support saves time and money when installing ceiling speakers that do not require a back box. It will work easily with any speaker baffle designed for an 8" speaker whether it is round, square, torsion or standard four hole mounting. This 24" tile support is easy to install. ETBST ETBST This tile support is the same as the ER800 however the ETBS bar supports are attached. It is a one piece unit built for a speedy install when a back box is not required. ETBS502 24" one piece tile support for use with EPCS502B speaker systems. ETBS502 Enforcer Sound- Square / Round Surface Back Boxes EBB-Flush Back Boxes EBB8SF Enforcer flush mount back boxes are of an all metal welded construction. They are all made from 23 gauge metal and have an acoustic damping material inside. The EBB8RFS is a stackable one piece back box. In addition to being very easy to handle these stackable back boxes take far less room to store and will save you money in shipping costs. Product Specifications: EBB4SF/RF z Available in a no mess finish - much better for handling. z Acoustic damping on all models. z Available in a variety of depths to meet installation needs. z Both torsion as well as standard 4 hole baffle mounting. z Stackable - saves time plus shipping costs. Comparison Chart EBB8RF2 EBB8RF7D For classroom stations, and gym ceiling speakers Nurse Call Part of GE Security CENTRAL EQUIPMENT Compatibility Î | StaffCallPro Pull cord stations and interface PTM Series, PUM01-B-D Maxi-use module Features Pull Cord Stations Mount to one-gang electrical boxes Manually resettable 5' (1.5 m) nylon cord with white ABS pendant Red LED indicator lamp PTM03-C Pull cord Code Blue station. PTM01-C Pull cord emergency station. Maxi-use Module Interface between passive peripherals and the master station Compatible with smoke detector relays and security contacts 32 inputs, 14 outputs Application Description Emergency pull cord stations are sturdy call points designed to initiate high priority calls. Emergency and Code Blue models are available. All models feature a strong nylon cord for easy access from any height, and an on-board LED provides instant visual confirmation that the call has been placed. The Maxi-use module is the interface that ties passive devices to a particular event on the system. It may be used to register at the master nurse station the status of individual call points, buttons, or relays, and to activate associated dome lamps and other devices in response to a change in status of one or all of its connected devices. The Maxi-use module accommodates up to 32 inputs, converting each to a 2-byte coded message, and 14 programmable outputs. The Maxi-use module and connected peripheral devices serve many purposes. As a supplement to bedside communication between the master nurse station and patient stations, emergency pull cord stations are typically installed in the patient’s bathroom: one in the shower and one near the toilet or sink. Similarly, Code Blue stations and 1-gang call stations may be installed anywhere there is a chance that staff or patients require immediate assistance. Fire alarm devices are also supported by the Maxi-use module. When the relay output of smoke detectors or fire alarm pull stations are connected to the module’s inputs, activation of the device can be programmed to automatically generate a priority 1 FIRE call to the master nurse station (this is for ancillary use only and is not a substitute for code-compliant fire alarm annunciation). IV monitors, door stations and many other contact-closure devices can be similarly configured to operate as addressed calls with the Maxi-use module. Maxi-use module visual display output capability is equally powerful. Outputs to dome lamps generate coded visual signals that depend on the nature of the input and its programmed priority. Master Station Display CODE FIRE EMERG. BATH x DOOR ALARM SHOWER Call Type Code blue (99) Fire alarm Emergency call Bath emergency station Open door alarm Alarm device activated Shower switch activated Priority 1 1 2 3 3 3 3 Corridor Dome Lamp Color Red Red/White Red White White Red White Flash Rate Fast Alternate Slow Fast Fast Slow Fast www.gesecurity.com imagination at work 27545 DIEHL ROAD, WARRENVILLE, IL 60555 P H O N E : 630-836-3700 • F A X : 630-836-3800 CANADIAN OFFICE: 560 PARKSIDE DRIVE, UNIT 401, WATERLOO, ON N2L 5Z4 Literature Sheet #85100-0026 Issue 1 Not to be used for installation purposes. Page 1 of 2 75 Years of Excellence VPCS-2GPB-X45 VPVT-PB VPB-1A VP-77 WPVT-4FN Vandal-Proof Intercom Stations Stations with Cone Loudspeaker & Call Switch Option Plate-Mounted Call Switch VPB-1A. Intercom accessory includes a vandal-resistant push button mounted to an all new single-gang, 12-gauge stainless steel plate which may be used in conjunction with VPV TPB, VPCS-2G-2(PB) and VPCS(PB) Series intercom stations. Switch may also be used as a stand alone signaling device when a separate or remotely located callorigination button is desired. Switch is a SPST normally open circuit with a 3-amp contact rating. Hardware installs using a 6–32 holt-head driver bit for a standard 1⁄4 " nut driver. Stations with Compression Driver & Call Switch Option VPV T-4PB Series. Loudspeaker station with high-efficiency compression driver mounted to a 12-gauge stainless steel plate provides two-way communication for vandal-proof use in detention facilities, correctional institutions, and secured access applications. Rugged recess-mounting assemblies incorporate the patented V T Series, environmentresistant compression driver; recognized throughout the world for dependable performance and effective voice and signal tone distribution. High-intelligibility, 8Ω compression driver also functions as a microphone to provide clear voice communication. VPV T-4PB incorporate a vandal-r esistant call-origination button with 3 amp contact rating to provide call-in signaling capability. Station available in high-power 15 watt models with 25V transformer. VPV T-PB Series measures 71⁄4 " square and installs into VP-77 backbox. Backboxes are ordered separately. Recessed Backbox for Vandal-Proof Stations VPV T-4PB. Protective backbox is constructed of 16-gauge CRS and finished in black textured enamel for installation of specified vandal-proof loudspeaker station assembly. Stations with Compression Driver and Call Switch WPV T-S / WPV T-F Series.. Surface and flush-mounting outdoor intercom and paging loudspeaker assemblies provide weatherproof and vandal-proof two-way communication with call-in capability for remote guard and security stations, entry and exit gates, perimeter doors and parking garages. Environment-resistant assemblies include die-cast water sealed V T Series 8Ω compression driver loudspeaker a vailable with 15 or 2 watt transformer and pre-mounted call SPDT-type switch protected by a weatherproof rubber boot. WPV T-S Series are surface mounting assemblies size 4 1⁄4 " Square x 3 1⁄8 " Depth. WPV T-F Series are recess / flush-mounting versions size 6" Square x 3 3⁄16 " Depth. Both model series are finished in neutral gray(N) epoxy and install to a standard 4" E.O. Box (not included). A large selection of installation accessories are also available. See Installation Accessories for Voice / Tone Loudspeakers page xx. AtlasSound.com 71 Vandal-Proof Intercom Stations VPCS Series. High-security vandal-proof loudspeaker stations are equipped with a 2 1⁄2 " diameter moisture-proof resin impregnated cone loudspeaker for clear voice / signal transmission with durable performance. The overall depth of all units is a shallow 2 1⁄8 " (54mm) allowing installation in standard size E.O. boxes. VPCS-2G Series and VPCS‑2GPB are 2-gang versions. VPCS-3GPB-245 is a 3-gang model. All models include a two-piece die-cast barrier (patent pending) to protect the loudspeaker assembly from vandalism. Models with “PB” designation include a vandal-proof call switch. The switch is a heavy-duty, momentary action push-button with a 1.5A 250VAC contact rating. The 25V transformer has .25, .5, 1 & 2 watt taps. Model Frequency Response SVT-27UCS Model 500Hz -5000Hz (±5dB) Power Taps Frequency Response Sensitivity >190˚ (-6dB point, 1 and 2kHz octave bands) Sound Level Dispersion 96.9dB (1 watt, 1 meter) UL: 90dB (1 watt, 10 ft) Impedance VTB-1 15 watts 400Hz – 4kHz 107dB 150˚ 8Ω VTB-2 15 watts 400Hz – 4kHz 107dB 150˚ 4Ω VTB-4 2, 4, 8, & 15 watts 400Hz – 4kHz 107dB 150˚ 25V VTB-6 1 & 2 watts 400Hz – 4kHz 100dB Model Series UL UHT Model Speaker / Transformer / Cap / Baffle Size 8" (203mm) 1480 UL Transformer 10 oz (283 g) 25V 1 UHT25C-U161-8 1480 25V 1 UHT70C-U51-8 1480 70.7V 1 UHT70C-U161-8 1480 70.7V 1 HPG-100N Model AS-100N Model Rectangular Molded Bell Power Rating Power Rating 100 watts Impedance 100 watts DC Blocking Capacitor Tip Assembly-Gray EST-527 ESB-974 Impedance 10 watts 8Ω 51-8 (Round) 95-8, 96-8 ⁄2, 1, 2, 5 10 mfd @ 50V 51-8 (Round) 95-8, 96-8 ⁄2, 1, 2, 5 4 MD @ 150V 161-8 (Square) 198-8, SE175-4 ⁄2, 1, 2, 5 4 MD @ 150V 161-8 (Square) 198-8, SE175-4 Sound Level Peak (dBA) Finish Dispersion 110dB 120dB 80˚ H x 105˚ V Plane Wave Freq. Response Low Freq. Limit @ Full Power 100Hz – 2.5kHz (±5dB) 400Hz Mounts 31⁄4" Length AS-100N Tip Assembly-Gray 51⁄4" Length AS-100N Loudspeaker Bell-Gray 5 ⁄2" Diameter x 3" Depth AS-100N 1 K-100N Replacement Head Assembly — YDA-TH Dual Driver Adapter 13⁄8"-18F, 13⁄8"-18M thread — HPG100N AS100N Description Dimensions 25V; 2-Gang 43⁄4" Square (121mm) 21⁄8" Depth (54mm) VPCS-2GPB-2 25V; 2-Gang w/ Call Switch 43⁄4" Square (121mm) 21⁄8" Depth (54mm) VPCS-3GPB-245 25V; 3-Gang w/ Call Switch Width 63⁄8" (162mm) Height: 43⁄4" (121mm) Depth: 21⁄8 (54mm) VPCS-2G-2 Model VPB-1A Model VPVT-4PB Description Width Plated Mounted 1-gang Call Switch Power Rating Transformer Height 23⁄4" (70mm) Frequency Response 41⁄2" (114mm) Call Switch Depth 13⁄8" (35mm) Optional Back Box 15 watts, 25V 25V — Width Height Depth Mounts VP-77 51⁄2" (139.7mm) 61⁄4" (158.75mm) 31⁄2" (88.9mm) VPVT-PB Series Model Power Rating WPVT-1SN 15 watts (8 Ω) — 600Hz – 5.5kHz -26dBm WPVT-4SN 15 watts 25V 600Hz – 5.5kHz -26dBm Model 146 Transformer Yes Frequency Response 10,600 Gauss Black Bell Black Driver HPG100N AS100N Model Flux Density Mounts Enclosure (Order Separately) Baffle Type 10 mfd @ 50V Size EST-510 25V Power Rating ⁄2, 1, 2, 5 11 Ω (nominal) Description 85Hz – 8kHz ±5dB Transformer Taps 1480 Description 150˚ Frequency Response Magnet UHT25C-U51-8 Model Specifications Dispersion VP-77 Sensitivity As Microphone 800.876.3333 Sound Level 117dBa Sensitivity 97dB (1 W / 1 M) Product WT-201A Miniature Pendant Transmitters The WT-201A miniature 12-bit pendant transmitter designed for emergency and remote control applications in wireless security and remote control systems. When activated, the WT-201A transmits a 12-bit message, selected by an internal DIP switch from 256 possible combinations. To assure reliable operation, an LED lights during transmission indicating that the battery is in good condition. An easy-to-use 4-channel selector enables users to program the transmitter to activate any one of the receiver's four outputs. For maximum wearing flexibility, the WT-201A pendant is supplied with a neck-chain and a key-ring clip. This comfortable and attractive miniature pendant is compatible with Visonic wireless receivers of the WR-200 and WR-300 series and other 12-bit devices. It is available in two frequency bands to comply with international standards, and are approved for use in most countries. WT-201A Features: l Single button programmable to activate any one of the receiver's 4 outputs. l Comfortable miniature attractive design. l Superior transmission range. l 12 V standard alkaline battery. l Visible low battery indication. l Neck-chain and key-ring wearing accessories included. l Available in two optional frequencies in compliance with international standards. l Compatible with all Visonic WR-200/WR-300 wireless receivers and 12-bit wireless devices. Product WR-200 Single-Output 12-Bit Wireless Receiver The WR-200 is a single-output wireless receiver operating in conjunction with a wide variety of Visonic 12-bit wireless devices, including portable and door/window transmitters, motion, glass-break and smoke detectors, coded keypads and range-extending repeaters. Designed for security, alarm and control applications, the WR-200 is easily integrated into virtually any security and remote control system. To ensure secure wireless communication, the WR-200 receiver only responds to transmitters that transmit the same system code. Users select a system code from 256 possible combinations, and quickly apply it system-wide, using the 8-position DIP switch on each device. A special "channel selector" enables setting the receiver output to respond to one of four possible communication channels of the transmitters. Each channel may be used for any type of alarm: emergency call, motion, glass-break, smoke, etc. If the correct system code and communication channel are detected, the WR-200 activates its relay output. The WR-200 wireless receiver is available in two optional frequencies in compliance with European, U.S. and other international standards, and is approved for use by local authorities in most countries. WR-200 Features: l Designed for security, alarm and control applications. l Easily integrated into virtually any alarm control panel. l Secure communication with transmitting device based on user-defined system code (selected from 256 possible combinations). l 4-channel selector for maximum control flexibility. l 11-14 Volt DC or AC power supply. l Available in two optional frequencies in compliance with international standards. l Supports the complete variety of Visonic 12-bit wireless devices. D225 and D400 DIGITAL SECONDARY CLOCKS D225 Digital Clock D400 Digital Clock Shown with Corridor Kit NATIONAL TIME offers a digital clock series with improved features over previous models. This new microprocessor based secondary clock and the MC-100 Master Clock form a unique time keeping system offering on demand time correction. This digital communication format can provide power and instantly correct all secondary clocks to any time of day using only two conductor low voltage wire. This format eliminates costly battery replacement and lengthy reset schemes. National's new energy saving power algorithm and current control circuitry combine to provide a low current, constant brightness LED display. 24VAC units are available in attractive 4" or 2.25" high visibility, wide-bar digits. For extremely long wire runs, 120VAC power and communication may leave the Master Clock when the appropriate 24VAC transformer is mounted at each clock or double face unit. For systems not utilizing National's Master Clocks, 12-hour resets may be accomplished with a short power interruption each 12:00. The durable steel housing, plug-in connectors and universal mounting plate simplify installation. An optional low profile surface box allows for surface mounted conduit entry. The corridor conversion kit will support top or side mounting, single or double face. Powder grey finish standard, other colors upon request. FEATURES On-Demand Correction 2-Wire Operation Accurate 60hz Timekeeping Low Power Consumption Long-Life Sealed Display Microprocessor Based Durable Steel Housing HighVisibility Plug-in Connectors BULLETIN C-419 07/03 Mounting Options Box By Others (Single,4"Square,Double) D400 w/ D3T xmr requires Deep Boxes. DxM-SURF BOX for Conduit Entry DxT-120/24 for 120VAC applications Flush Mount Surface Mount Fig. 1 DxT-120/24 for 120VAC applications Fig. 2 4"Square, securely mounted Single Face/ Top Mount Fig. 3A Double Face/ Side Mount Double Face/ Top Mount Fig. 3B Single Face/ Side Mount Not Shown Fig. 3C For extra protection, see our Clear-View Digital Clock Protector. Bulletin C-417 Specifications Voltage Requirements: PART # VOLTAGE RANGE D225 24VAC 16-32VAC 120VAC 105-132VAC D400 24VAC 16-32VAC 120VAC 105-132VAC Current 57mA 15mA 85mA 30mA 24VAC: Clocks will function with 24VAC with no modifications. 120VAC: Supported with addition of these transformers: D2T-120/24 - Supports Single Face D225 D3T-120/24 - Supports Double Face D225; Single or Double Face D400 The transformer mounts to the back of the mounting plate and extends into the surface box or electrical box. The D2T-120/ 24 protrudes 1.18", the D3T-120/24 protrudes 1.75". (May require a Deep Double Gang or Deep 4 Square backbox or the D4M-SURF BOX.) Correction Formats Supported: On Demand Correction: When used with National Time MC-100 Master Clock, clocks can correct to any time of day. Only 2 low voltage wires required. 12 Hour Reset: An 'off' pulse (0.5 sec. min) at 12:00 will reset all clocks. Ordering Info Part # D225 D400 D2M-SURF BOX D4M-SURF BOX D2M-CORR KIT D4M-CORR KIT D2T-120/24 D3T-120/24 Fig 1 1 2 2 3 3 - Description 2.25" Digital Clock with Mounting Plate 4" Digital Clock with Mounting Plate Surface Mount Box for D225 Surface Mount Box for D400 D225 Corridor Conversion Kit; Side or Top Mount* D400 Corridor Conversion Kit; Side or Top Mount* 120/24VAC Transformer for Single/Double Face D225 120/24VAC Transformer for Single/Double Face D400 Mounting 4 Square, Double, Single 4 Square, Double, Single 4 Square, Single,W all Surface 4 Square, Single,W all Surface Securely mounted 4 Square Securely mounted 4 Square 4 Sq, Dbl Gang,Surf/Corr. Box D2M Corridor Kit Dim A 10.13 16.88 10.13 16.88 5.00 5.00 - B 5.06 7.13 5.06 7.13 6.30 8.44 - C 1.13 1.38 2.63 3.38 3.75 4.75 - D 11.40 18.20 - *Clocks and Transformer (if necessary) Sold Separately. PHONE (248) 380-6264 FAX (248) 380-6268 28045 OAKLAND OAKS CT. WIXOM, MI 48393 DIGITAL CLOCK PROTECTIVE GUARD CV-GUARD-S NATIONAL TIME now offers a digital clock protective guard superior to other models. Manufactured with heavy duty 18 gauge steel, this guard will stand up to the most demanding installations. The tough polycarbonate window provides obstruction-free viewing of the clock not found in wire guard versions. The Semi-flush Clear-View Guard will protect up to a 4" digital clock when installed using a flush mounted electrical box. The Surface Clear-View Guard is used when a surface mount enclosure such as D4M-SURF BOX is used. (See Bulletin C-394) This deeper guard has a slot centered on one side to accommodate surface conduit or other surface mount wire raceways. The guards are finished with Powder Gray paint to match the standard digital clock finishes. Other colors are available upon request. CV-GUARD-F FEATURES Durable Welded Steel Housing Tough Polycarbonate Window Obstruction-Free Viewing Surface and Semi-flush Models Protects up to 4" Digital Clock Easy Installation BULLETIN C-417 10/02 Dimensions Model CV-GUARD-S Shown covering D2M with D2M-SURF BOX Model CV-GUARD-F Shown covering D4M Appropriate mounting hardware for wall construction type required Ordering Info Part # CV-GUARD-F CV-GUARD-S Description Clear View Guard for up to 4" Semi-Flush Digital Clocks Clear View Guard for up to 4" Surface mounted Digital Clocks PHONE (248) 380-6264 FAX (248) 380-6268 28045 OAKLAND OAKS CT. WIXOM, MI 48393 Rotary Drive Wall Clocks Case Style FR Round NATIONAL TIME is pleased to reintroduce the impulse time system- with today's high tech performance! Microprocessor technology has replaced the slow, troublesome spring/ratchet/solenoid engagement designs currently offered by other manufacturers. National's revolutionary Rotary Drive time system can instantly correct all of the building clocks to the exact hour and minute at any time of the day! With our on demand instant time correction, you no longer have to wait up to twelve hours or perform confusing, tedious sequences of manual stops, starts and resets. We give you the correct time when you need it --- NOW! For systems not incorporating the National MC100, On-Demand correction may be achieved using the PS-3-OD Power supply or URTOD-HH module. See C-429 and C-434. Rotary Drive guarantees to outperform all existing clock technology without sacrificing the unsurpassed durability you have come to expect from National Time's synchronous motor drive systems. The 3WS series will emulate most existing synchronous clock operation without the frailties of solenoids, ratchets, switches or levers. See Compatibility List bulletin C-430. Each clock is equipped with an all metal case, convex glass crystal, and white polystyrene dial having black markings and hands. A sway-proof hanger plate is furnished that securely holds clock to wall. Cases are attractively finished in Powder Gray enamel. Other finishes and shatterproof lens are available upon request. Shatterproof lens now standard on 12” round. Refer to Bulletin C-323 for classic dial series. Case Style FQ Square FEATURES Revolutionary Rotary Drive Design Microprocessor Controlled On-Demand Instant Correction Universal Reset Operation Swift, Smooth, Ratchet-free Operation Compatible with Existing 2 & 3 Wire Minute Impulse Systems Compatible with Existing 3Wire Synchronous Clocks BULLETIN C-332 rev.B Ordering Information and Specifications Surface Mount Clocks Flush Mount Dial Size 10" Round 12" Round 12"Square 16"Round 24" Round Dim A Outside Dia. 11-1/4" 13" 12-1/2" 16-1/2" 24" Dim B Box top to Clock Top 2" 3-1/4" 2-3/4" 4-3/4" 8" Surface Mount Dial Size 10" Round 12" Round 12"Square 16"Round 24" Round Dim A Outside Dia. 11-5/8" 13-7/16" 12-1/2" 17" 24" Dim B Box top to Clock Top 1-1/8" 13/16" 5/8" 3/4" 11/16" SR-12RD-2WS-03-SP Analog Clock DR-12RD-2WS-03-SP Double faced analog clock Ordering Information Case Style Size S=Surface D=Double Face Shape: R=Round Q=Square Model No. 2W I-00 3W I-00 2W S-03 3W S-00 Part No. D2T-120/24 D4T-120/24 Insert Model number from below SR-12RD-MODEL NO.-SP Rotary Drive Movement SP= Shatter-Proof convex crystal (Leave Blank for Standard Glass) -SP now standard on 12” Round Description 2-W ire Impulse; 24VDC; Reverse Polarity; On Demand resets 3-W ire Impulse; 24VDC; On Demand resets 2-W ire Sync hronous; 24VAC; On Demand Resets; 12:00am/pm resets 3-W ire Sync.;24VAC; On Demand resets or 59th or 00 minute Synchronous Compatible 120VAC to 24VAC Transformer for Single Fac e 2W S or 3W S Clock 120VAC to 24VAC Transformer for Double Face 2W S or 3W S Cloc k See Bulletin C-430 For Compatibility List. Consult Factory for other reset Compatibilities or Custom protocols Compatibility: May be used in-line with existing clock types. On Demand resets require National’s Master. On synchronous systems, On Demand resets will not effect existing clocks. On impulse systems, existing impulse clocks cannot occupy the same circuit if On Demand resets are desired. Synchronous Resets: 8 second hour, 14 second 12hr; 25 second hour, 25 minute 12hr; 2 second 12hr; 55 second hour. See C-430 for compatibility list. Operating Voltage: 24VDC versions:19-32VDC @ 150mA; Filtered DC supply required for 24VDC On Demand resets. 24VAC versions: 16-28VAC @ 3.8W; 120VAC versions 102-132VAC @ 3W (Require D2T-120/24 or D4T-120/24 Transformer) U.S. Patents 5,282,180; 5,442,599; Patents Pending PHONE (248) 380-6264 FAX (248)380-6268 21800 WYOMING AVE. OAK PARK, MI 48237-3195 TC Series Models c/w Heavy Duty Bracket Mounting and Terminals Primary Sec. Volts Volts. 25VA 50VA 75VA 100VA 150VA 120 24 TC2524-1 TC5024-1 TC7524-1 TC10024-1 TC15024-1 - 120 TC25120-1 TC50120-1 TC75120-1 TC100120-1 TC150120-1 208 24 TC2524-2 TC5024-2 TC7524-2 TC10024-2 TC15024-2 - 120 TC25120-2 TC50120-2 TC75120-2 TC100120-2 TC150120-2 240 24 TC2524-3 TC5024-3 TC7524-3 TC10024-3 TC15024-3 - 120 TC25120-3 TC50120-3 TC75120-3 TC100120-3 TC150120-3 277 24 TC2524-4 TC5024-4 TC7524-4 TC10024-4 TC15024-4 - 120 TC25120-4 TC50120-4 TC75120-4 TC100120-4 TC150120-4 - 120/240 TC25120D-4 TC50120D-4 TC75120D-4 TC100120D-4 TC150120D-4 347 24 TC2524-5 TC5024-5 TC7524-5 TC10024-5 TC15024-5 - 120 TC25120-5 TC50120-5 TC75120-5 TC100120-5 TC150120-5 - 240 TC25240-5 TC50240-5 TC75240-5 TC100240-5 TC150240-5 - 120/240 TC25120D-5 TC50120D-5 TC75120D-5 TC100120D-5 TC150120D-5 Quantity as required Print This Page | Close Window Model GR-FS4B2723TDB Category Metal Floor Racks Product Description 27U, 23" Deep Rack w/Glass Door Features: Floor Standing Rack; 27U, 23" Deep; Steel Back Door; Vented Glass Front Door • • • • • • • • • • • • Meets ANSI/EIA RS-310-D, DIN41491;Part1, IEC297-2, DIN41491;Part7, GB/T3047.2-92 standards 18 gauge removable side panels with spring latch 18 gauge SPCC cold rolled steel top and bottom Perforated top 11 gauge front rack rails 10/32 rack screws Rack U number printed on the rack rails 1/2", 5/8", 3/4", 1"1 and 1 1/2" cable entry knockouts on top and bottom 5/8" knockout design to be used for VHF/UHF antenna Black powder coated finish Adjustable depth front rack rails Front door features toughened glass with vented sides and spring loaded push and turn locking system Color: Black Hinges: Hinged Doors Latches: Lockable Doors Wheels Optional Casters Interior Dimensions Interior Width: 19.00'' Interior Height: 47.25'' Rack Dimensions Rackable Depth (to rear lid): 22.25'' Rack Units: 27 Exterior Dimensions Shipping Dimensions Exterior Length: 57.40'' Exterior Length: 57.40'' Exterior Width: 23.60'' Exterior Width: 23.60'' Exterior Height: 23.60'' Exterior Height: 23.60'' Weight: 152.1 Weight: 152.1 REQUIRES 120VAC RECEPT IN CEILING SPACE. REQUIRES 1 HOME RUN OF 2 TWISTED PAIRS PERSONAL ALERT RECEIVER IN CEILING SPACE OF CHALLENGING NEEDS HOME RUN 2 TWISTED PAIR TO INTERCOM SYSTEM HEADEND RONCOLI SCHOOL - ST. JOHN'S NOTE: CLOCK WIRE IS 2 #12 WITH A MAXIMUM OF 30 CLOCKS PER ZONE DUAL FACED CLOCK COUNTS AS TWO IC WIRE iS 2 TWISTED PAIRS MIN 24AWG DOOR INTERCOM STATION MOUNTED IN 2-GANG BOX