Roncolli School Expansion - BF Kennedy Sound Systems

Transcription

Roncolli School Expansion - BF Kennedy Sound Systems
N. S. C. A.
BF Kennedy Sound Systems Ltd.
Main Highway - Roaches Line
P.O. Box 191 - South River - Newfoundland
Canada - A0A 3W0
email:[email protected]
Tel: (709) 528-1360
www.bfksound.ca
P roud M ember of the N ational
Systems C ontractors A ssociation
Fax: (709) 528-1182
Roncolli School Expansion
27 53 13 - Clock (Intercom & Program) System - Shop Drawings
•
MCS350
intercom system (with 48 circuits)
•
ACC5
administrative control console
•
TPU100
100 watt amplifier
•
RCD350P
Tuner CD Mixer (c/w MP3 input)
•
Universal
whip antenna
•
PD-D2610
5 Disc CD Player
•
WebSchedule
PC Remote/Local Programming Software
•
Omnismart1500
1500VA UPS
•
PCSG-25-MP
classroom station
•
EMT501B
corridor/washroom speaker
•
ETBS
T-Bar support
•
Drawing
paging speaker mounting detail
•
E86CWT5SA
gym (and wallmount) paging speaker
•
EBB8SF
square speaker back-box
•
PTM-01C
washroom pullcord station
•
EAM-10W
volume control
•
VPCS-2GPB-2
Vestibule intercom station
•
WT-201A
Wireless Pendant Transmitter
•
WR-200
Wireless Receiver
•
D225
Digital clock
•
CV-Guard-F
Lexan cover (for gym clocks)
•
D2M-Corr-Kit
double faced corridor clock
•
CV-Guard-F
lexan guard for clock in gym
•
SR-12RD-2WS-03-SP
Analog Clock
•
TC10024-1
clock power supply
•
310-120
Bells c/w PVC box
•
GR-GFS4B2723TDB
27U floor rack
•
Drawing
Updated IC/CLOCK Riser
Sound, Communications and Security Systems for Education, Health Care and Industry
MCS350 Series
Communications Systems
MODULAR
COMMUNICATIONS SYSTEM
Wall Mount
Features
• Advanced
Microprocessor Design
• Simultaneous Program
Distribution and
Two-Channel Intercom
• Built-In and Remote
Diagnostics
• Selectable SingleQueue Operation
• PC Interface for
Remote System
Programming
• Twenty-Five
Programmable Tone
Types
• User-Programmable
Input Ports and Output
Contacts
• RS-485 Serial Port
• User-Programmable,
Battery-Backed Master
Clock
General Description
The Dukane MCS350 Series is a multichannel, microprocessor-controlled, programmable administrative communications system that provides a range of audio
communications functions. These functions are initiated from any one of up to four
Administrative Control Consoles (ACCs) that can be connected to the system. The
entire system of ACCs and up to 256 remote stations are controlled by a Dukane
Model MCS350 Central Control Unit (CCU). Two-way open voice communications
can be initiated from an ACC to any remote speaker station or to another ACC.
Paging and program distribution can also be initiated by an ACC to any one station or
group of remote stations. The built-in master clock can be programmed to control
time tone distribution to any or all remote stations. The master clock can correct selected synchronous clocks or selected digital clocks. The clock has a battery backup
to maintain the correct time for seven days after power loss.
DUKANE CORPORATION | COMMUNICATIONS SYSTEMS DIVISION | 2900 DUKANE DRIVE | ST. CHARLES, ILLINOIS 60174
ISPA/MCS350/Telapex
All specifications subject to change without notice.
427-01-00078 (03)
(General
Description)
The MCS350 has three independent audio communications paths: one program channel and two open-voice intercom channels. All three channels can be active
simultaneously, without interruption. The program channel is used for paging, time
signaling, and program distribution to multiple remote stations. The two intercom
channels allow two simultaneous intercom conversations: one between an ACC and a
remote station, the other between two ACCs. Two simultaneous ACC-to-ACC conversations are also possible. Program channel communications need not interrupt
remote station intercom use.
The ACC is a desktop unit that initiates and displays all MCS350 functions. The ACC
consists of a protective housing, a 31-key, color-coded, spillproof key pad, a
16-character alphanumeric LCD, a built-in microphone and speaker, and a two-way
handset. ACC key pad entries are accompanied by both audio and visual feedback.
The EMERGENCY, CUSTODIAN, PAGE, PROGRAM, CONSOLE, SYSTEM, and
HOLD keys have accompanying LEDs to indicate the function status. The ACC also
has speed dial, redial, manual time-tone generation, and program monitoring
capabilities.
ACC users have program channel access for zone paging to preselected groups of
remote stations or for all call paging. Remote stations can be assigned to more than
one zone. ACC users can also program the entire system by entering the user-assigned
access code. The built-in programmable master clock allows 256 discrete time event
entries. Each event is assigned to one, a combination of any five, or all eight time
zones; one of eight time schedules; one of eight user-programmable tone types; and
any combination of days of the week. The system master clock can be synchronized
by an external master clock system. All system programming is stored in non-volatile
(EEPROM) memory and is retained in the event of power failure.
The 16-character LCD display keeps the user informed of current ACC status at all
times. When no calls are in the system, the display shows the time of day in either 12or 24-hour format. As calls are received by the ACC, the display shows the two-,
three-, or four-digit alphanumeric room number of the calling station as well as the
call’s position in that ACC’s call-in queue. Each ACC has its own individual queue
for storing incoming calls. These queues are user-programmable so that any room can
be programmed to call into any one of the ACCs. All rooms can also be programmed
to call into a single ACC. The ACC indicates each call it receives by sounding a
call-in tone and updating its queue status display. Calls into an ACC are inserted into
the queue first according to their priorities, then in order of arrival. Five call-in priority levels are user-programmable for each remote station: emergency, ACC call-in,
high priority, staff, and normal. The system has 100 percent queuing of incoming
calls so no calls can be lost. Incoming calls can be scanned using the DISPLAY
CALLS key and can be answered in any order desired. An ACC can place a call with
calls waiting in its queue. A single queue mode that places all incoming calls into a
single common queue can be selected. This allows directing all incoming calls to all
ACCs during limited staff operation.
2
MCS350 Modular Communications System
For voice intercom or paging functions, the ACC is equipped with a handset, key pad,
speaker, microphone, and a PUSH TO TALK key. The handset is engaged whenever
it is in a non-horizontal position. Voice-activated switching (VOX) automatically
switches audio direction. When the handset is not active, the direction of communication is controlled by the PUSH TO TALK key. The built-in microphone is active
when the PUSH TO TALK key is pressed and the speaker is active when that key is
released.
(General
Description)
The system has user-programmable input ports that allow external devices to trigger
time and emergency tones, external all call, door monitor, night transfer switch, and
other system functions. User-programmable dry-contact outputs are provided to signal
external devices when functions such as clock synchronization, all call, and remote
annunciations occur.
The system tone generator provides 25 tones. The volume level and duration of each
tone is programmable.
The MCS350 System includes off-hour door alert, a programmable alarm tone for
sounding a door alarm in all or selected zones by the closure of a single switch contact.
The Model MCS350 Central Control Unit consists of one digital card, one analog
card, one or more SC16 or SCX16 Switching Cards, one 24Vdc power supply, and
one or more 60-watt power amplifiers. A single switching card can handle up to 16
remote stations. The MCS350 can contain up to 16 switching cards, resulting in a system capacity of 256 remote stations. The MCS350 performs self-diagnostic tests for
detection of various system errors or invalid keystroke sequences. If a system error is
detected, a message is displayed on each ACC in the system.
The MCS350 System has an RS-232 port for a PC or a Dukane SmartSystem® interface that allows menu-driven programming of system information (room numbers,
zones, events), storing system programming on diskette, establishing a system directory of teacher names with room numbers, adding and deleting rooms from zones,
logging and storing priority system activity, and retrieving data for review and printing. An RS-485 port provides for long distance serial communications with future
equipment.
The Dukane MCS350 is available in two models: a wall-mount version and floor rack
version. The wall-mount version can accommodate up to four switching cards (64 remote stations), a 24Vdc power supply, and a 60-watt power amplifier. The floor rack
version is an upright 19-inch (48.3 cm) rack unit that houses the Central Control Unit
as well as an optional AM-FM tuner/cassette player (with or without preamp).
The 19-slot card cage in the rack model can contain up to 16 switching cards (256 remote stations). The rack also houses the 24Vdc power supply, and up to six 60-watt
power amplifiers. A single power amplifier is recommended for each set of 64 remote
stations.
MCS350T Administrative Communications System
3
RATED OUTPUT
25V line or 45Ω system
PROGRAM:
Wall cabinet: 60W (rms)
Rack mount: 60W to 360W (rms)
INTERCOM: 4W (rms)
Specifications
POWER REQUIRED
MCS350 WALL CABINET: 105Vac to 132Vac @ 3A
MCS350/R RACK: 105Vac to 132Vac @ 10A
INPUTS
External program source
INPUT SENSITIVITY
EXTERNAL PROGRAM SOURCE: 500mV nominal
INTERCOM: 500mV nominal
FREQUENCY RESPONSE
PROGRAM: 50Hz to 15kHz
INTERCOM: Voice-filtered for maximum intelligibility
COMPRESSORS
Automatic level control of both talk and listen
DISTORTlON
PROGRAM: Less than 2% at full load
INTERCOM: Less than 2% at full load
NOISE LEVELS
EXTERNAL PROGRAM SOURCE: –60dB
INTERCOM: –60dB
OUTPUT REGULATION
PROGRAM: Better than 2dB from no load to full load
INTERCOM: Better than 2dB from no load to full load
FUSES
WALL CABINET POWER SUPPLY: AC—0.75A slow blow, DC—3A fast blow
RACK MOUNT POWER SUPPLY: AC—1.25A slow blow, DC—5A fast blow
60W POWER AMPLIFIER: AC—1.25A slow blow, DC—5A fast blow
CENTRAL CONTROL UNIT (MCS350) MAIN: 5A slow blow
SWITCHING CARDS: 0.25A slow blow
ACC: Four 0.25A slow blow
EXTERNAL PROGRAM SOURCE: One 0.5A slow blow
INTERFACES
RS-232 port
RS-485 port
Clock correction
Input port: Four input closures
Output port: Two digital, two relay
MCS350T Modular Communications System
5
(Specifications)
TERMINATIONS
EXTERNAL: “BIX” Telecommunication-type
INTERNAL: “MAS-CON,” “LAT-CON,” “CHAMP” and screw terminal types
DIMENSIONS
MCS350 WALL CABINET:
21" (53.3 cm) wide x 28" (71.1 cm) high x 4-3/8" (11.1 cm) deep
MCS350/R RACK:
Standard 19" (48.3 cm) rack, 54" (137.2 cm) high x 21" (53.3 cm) wide x 17"
(43.2 cm) deep
NET WEIGHT
MCS350 WALL CABINET: 47 to 50 pounds (21.2 to 22.5 kg)
MCS350/R RACK: 139 to 228 pounds (62.6 to 102.6 kg)
FINISH
MCS350 WALL CABINET:
16-gauge steel backbox finished in matte gray baked epoxy
MCS350/R RACK:
Steel floor rack finished in charcoal black baked epoxy
TONES
Intercom Call-In
Intercom Call-Out
Privacy
Page Preannounce
Emergency Page Preannounce
Civil Emergency
Custodian
Eight Time Tones
Door Alert
CONTROLS
Full system control from any ACC
ENVIRONMENTAL PARAMETERS
32° F (0° C) to 90° F (32° C), relative humidity 0 to 90%
CAPACITY
c/w 3 cards
MCS350 WALL CABINET:
Sixteen stations expandable to 64 stations
One to four SC16 or SCX16 switching cards, 16 circuits per card
Up to four Administrative Control Consoles (ACCs)
One 60W power amplifier
MCS350/R RACK:
Sixteen stations expandable to 256 stations
One to sixteen SC16 or SCX16 switching cards, 16 circuits per card
Up to four Administrative Control Consoles (ACCs)
Up to six 60W power amplifiers
6
MCS350 Administrative Communications System
ACC5
Administrative Control Console
Associated
Equipment
9A1765
Call Switch (Pushbutton)
PCS499
Call Switch, Three-Position Rocker
PCSG3lWSE-25
Speaker Assembly (Flush) Square Baffle with Call-In Switch
PCSB303SE-25
Speaker Assembly (Surface) with Call Switch
PCS819
Dynamic Transmitter; Magnetic Receiver; 6' (1.8 m) Coiled Cord; for Two-Gang
Backbox
PCS822
Dynamic Transmitter; Magnetic Receiver; 6' (1.8 m) Coiled Cord; for
Single-Gang Backbox
PCS82l
Dynamic Transmitter; Magnetic Receiver; 6 (1.8 m) Coiled Cord; Rocker Call-In
Switch; for Single-Gang Backbox
RTC350
AM-FM Tuner/Cassette Player (Rack Mount)
RTC350P
AM-FM Tuner/Cassette Player (Rack Mount) Including Preamp and Monitor
Speaker
TC350
AM-FM Tuner/Cassette Player (Desk Mount Cabinet)
TC350P
AM-FM Tuner/Cassette Player (Desk Mount Cabinet) Including Preamp and
Monitor Speaker
MCS350T Modular Communications System
7
Model ACC5
ADMINISTRATIVE
CONTROL CENTER
Features
• 16-Character,
Alphanumeric
Liquid-Crystal Display
• Built-In Speaker,
Microphone, and
Handset
• Two-, Three-, or
Four-Digit
Alphanumeric Dialing
• 12- or 24-Hour Clock
Display
• Menu-Assisted,
User-Programmable
Functions
• Queues 100% of
Remote Call-Ins
• Color-Coded, Spill
Protected Key Pad
• Function Keys with
ON/OFF LED
Indicators
• Call Forwarding and
Transfer Capabilities
• Call Priority Levels
• Built-In Diagnostics
• Off-Hook Handset
Switch in Cradle
General Description
The Dukane Model ACC5 Administrative Control Console (ACC) is the control center
for communication, paging, signaling, and programming for the Dukane MCS350
Series and MCS350T Series Administrative Communications Systems. The ACC
incorporates a telephone handset, microphone, speaker, volume control, 16-character
alphanumeric liquid crystal display (LCD), and key pad controls. The control panel
allows the operator to establish two-way communications between an ACC and any
remote station or another ACC. The operator can also answer incoming calls and
selectively distribute external program sources to particular remote stations or zones.
In addition, the ACC allows all-call or zone paging, separate emergency paging, and
civil emergency tone distribution to all stations. A dedicated key provides a unique
custodial call tone to all speakers.
All ACCs in a system have identical functions and control features, yet each can be
independently programmed to perform specific operations for particular secretarial or
administrative needs. Functions such as alphanumeric architectural room numbering,
call-in priority levels, and the 256-event, eight-schedule and eight-zone time clock are
user programmable from the ACC control panel. The LCD provides menu-assisted
prompting and instructions during system programming, and visual indication of
regular and/or emergency incoming calls, paging zone selections, and room selections
during routine operation. The system provides, as a minimum, simultaneous intercom
to any speaker location, intercom between two ACCs, and program distribution to any
combination of individual remote stations or zones.
DUKANE CORPORATION | COMMUNICATIONS SYSTEMS DIVISION | 2900 DUKANE DRIVE | ST. CHARLES, ILLINOIS 60174
ISPA/MCS350/Telapex
All specifications subject to change without notice.
Document 427-01-00079 (04)
(General
Description)
The ACC’s telephone-style housing is made of molded, high-impact plastic and consists
of an alphanumeric LCD, speaker, microphone, handset, and touch-sensitive membrane
key pad for call operations, paging, and program distribution. The control panel is
organized in a logical, color-coded format to ensure ease of operation. Function key F5
is factory-configured for redial. All other function keys are user-configurable for speed
dialing or other specific system operations.
The large, 16-character LCD provides 100 percent queuing of calling room numbers,
call priority, sequential display of calls waiting, current time in the idle state, menu
assistance during system programming, and an operator dialing display.
The ACC displays multiple calls by priority and order of call-in sequence on the
LCD. A scrolling feature allows the operator to view pending calls and, if desired,
answer a call out of sequence.
Routine calls are audibly announced by a call-in tone and visually indicated by the
appearance of the calling station’s number and call priority level. These calls can be
answered using the handset or built-in microphone, placed on hold, transferred to
another ACC, or terminated.
Emergency and high priority calls are distinguished by a long, unique alert tone and
flashing station number. These calls can be answered, placed on hold, and transferred
to another ACC. During times of limited staff operation, calls can be temporarily
forwarded to another ACC in the system.
The ACC operator can place a call to any remote station in the system having audio
capabilities. At the same time, two other ACC operators can be in communication
with each other. Calls to remote speaker stations are made with a preannounce tone
and generate discrete, intermittent privacy tones to remind the receiving party that the
lines of communication are open. The ACC allows automatic one-button redialing of
the last number dialed by pressing the F5 function key. It also provides four additional
function keys with nine function locations (F1–F4 and F6–F10 using SHIFT key) for
speed dialing frequently called numbers.
The ACC operator can page up to five zones selectively or all eight zones in the system.
The all page feature disregards zone assignments and allows paging to all remote stations.
In addition to conventional paging, the ACC operator can generate an emergency tone
with a page, and civil emergency and custodial tones without pages.
The ACC operator can program the system clock for automatic time tone distribution.
A maximum of 256 events and eight schedules are available. Authorized ACC operators can alter the parameters of a programmed event at any time. Time tones can also
be distributed manually by an ACC operator, in addition to the automatic time tones.
The ACC provides the means for system programming and initialization. Call-point
designations, call-in priorities, zones for paging, time tone distribution, and program
event schedules are user-programmable features that can be altered by authorized
personnel as facility needs change. System programming is protected by a user-assigned
access code.
2
ACC5 Administrative Control Center Product Data Sheet
Audio programming can be distributed manually by the ACC operator to any combination of up to eight zones in the system, with monitoring at the ACC any time before
and during the distribution of the program.
(General
Description)
OUTPUT
Telephone line level
Specifications
SPEAKER
2.5" (6.4 cm), 8Ω, 3W
MICROPHONE
Built-in condenser type
HANDSET AND CORD
Electret transmitter
Dynamic receiver
Grey, flame-retardant, high-impact plastic with 3' (0.9 m) plug-in modular cord set
CONTROLS (KEY PAD)
Speaker VOL with plus or minus volume displayed on LCD
EMERGENCY key with LED on/off indication
PAGE key with LED on/off indication
PROGRAM key with LED on/off indication
CUSTODIAN key with LED on/off indication
DISPLAY CALLS key
HOLD key with LED on/off indication
PUSH TO TALK key
CANCEL key
ENTER key
CONSOLE programming with LED on/off indication
SYSTEM programming with LED on/off indication
NEXT
SELECT
EXIT
KEY PAD
0 through 9 (A through J using Shift key)
SPECIAL FUNCTION KEYS
F1 through F4 (F5 is factory programmed as redial key; access F6 through F10
using Shift key)
POWER REQUIREMENTS
24Vdc obtained through connection to MCS350 or MCS350T
DATA SIGNAL REQUIREMENTS
7,800 baud between ACC and central processor
ACC5 Administrative Control Center Product Data Sheet
3
(Specifications)
DISPLAY
Large 16-character LCD alphanumeric readout
TONES
User-programmable time, alarm, and call-in tones
SWITCHES/KEY PAD
Sealed, spill protected polycarbonate membrane
FUNCTIONS
ACC-to-speaker page
ACC-to-speaker/microphone intercom
ACC-to-ACC intercom
Queuing of incoming calls (100%)
Sequential displays of calls queued
Call hold
Call forwarding
Sequential display of priority stations
Display of current time in idle state
Full display of programmer prompting
Full display of operator function dialing
LEDs indicate function keys on/off
Audio program distribution control
Zone page
All call page
TERMINATIONS
Standard 8-wire locking plug-in telephone connector
HOUSING
High-impact, flame-retardant, grey plastic
DIMENSIONS
9.5" (24 cm) wide by 4" (10.2 cm) high by 8.75" (22.2 cm) deep
(dimensions include handset)
NET WEIGHT
3 lb, 10 oz (1.63 kg) including handset
Associated
Equipment
Model MCS350
Administrative Communications System
Model MCS350T
Administrative Communications System with Telephone Integration
Model SC16
Four Wire Switching Card (expander), 16-circuit
Model SCX16
Two Wire Switching Card
Model 9A1765
Call-In Switch (pushbutton)
4
ACC5 Administrative Control Center Product Data Sheet
Telephone
Paging
Amplifiers
Models
TPU35B,TPU60B,
TPU100B & TPU250
Description
Bogen models TPU35B,TPU60B,TPU100B, and TPU250 are wall-mounted telephone paging amplifiers rated at 35, 60, 100, and 250 watts,
respectively. The TPU250 can also be rack-mounted.This group of TPU amplifiers permits paging from telephone and/or microphone. Music
input through an RCA jack or screw terminals.Voice-activated, variable level, music mute with fade back after page. All the TPU amps in
this group include a night ringer which sends an electronic ringing tone signal through all speakers, alerting personnel of incoming calls
during non-business hours. Jacks are also provided to bridge two TPU amplifiers to double the number of inputs and outputs.
Features
• 35, 60, 100, and 250-watt models
• Bass and treble controls
• Inputs for 600-ohm balanced telephone line, LO-Z balanced
microphone, and background music
• Built-in night ringer activated by contact closure or by 90V
ring signal
• Music input (RCA jack or screw terminals)
• Balanced or unbalanced 16-ohm, 25V, 25VCT, and 70V outputs
are available for the TPU35B/60B/100B models; 25V and 70V
outputs are available on the TPU250
• Integral automatic level control (ALC) circuit for controlling
pages made by persons with varying voice levels and paging
techniques
• VOX sensitivity level control eliminates transmission of background noise when paging from a telephone
• Page from telephone and/or microphone
• Thermal and electronic overload protection
• Signal-activated paging channel automatically mutes background music
• Adjustable background music muting level during a page
• Jacks provided for bridging additional TPU amplifiers
• Brackets are attached for easy wall mounting;TPU250 can be
rack-mounted
• Music gradually returns to its normal level after a page
• TPU-B models can be rack-mounted with RPK82 kit
• Aphex® Aural Exciter increases intelligibility, improves
perceived loudness (with no increase in power), and reduces
listener fatigue
• Separate controls for page volume, music volume, night ringer,
music mute, and Aphex® Aural Exciter
• Peak level indicator lights when amplifier is driven into clipping
• 120V AC, 60Hz power source
• UL and CSA listed
Specifications subject to change without notice.
© 2000 Bogen Communications, Inc.
Part No. 54-7836-02R3 Printed in U.S.A. 0101
Aphex® is a registered trademark of Aphex Systems, Ltd.
Technical
Specifications
Power Output:
Frequency Response:
Distortion:
Hum & Noise:
Sensitivity:
Tone Control:
Regulation:
Inputs:
Outputs:
Controls & Indicators:
Overload Protection:
Power Requirements:
Operating Temperature:
Finish:
Dimensions:
Shipping Weight:
TPU35B: 35W RMS; TPU60B: 60W RMS; TPU100B: 100W RMS; TPU250: 250W RMS
70Hz to 15kHz ±1dB
Less than 1%
(20Hz to 20kHz) MUSIC: -70dB; TEL: -70dB; MIC: -55dB
MUSIC: 85mV; TEL: -20dBm (77mV); MIC: 600µV
BASS: ±9dB @ 100Hz; TREBLE: ±9dB @ 10kHz
2dB
TEL: 600-ohm balanced line, transformer-isolated
MUSIC: Hi-Z source, RCA jacks or screw terminals
MIC: LO-Z balanced, screw terminal connection
MUSIC MUTE: Mutes music during a microphone page
CONTACT RING: Sounds night ringer tone when customer-supplied dry
contacts are closed
TEL RING: Sounds night ringer in response to 90V ring signal
BRIDGING: Permits bridging of two amplifiers
25V, 25VCT, and 70V, 16 ohms balanced or unbalanced for 35/60/100-watt models;
25V and 70V for TPU250. Provision for WMT1A line-matching transformer
POWER & PEAK LEVEL LED indicators. APHEX,TREBLE, BASS,VOX SENS,
RINGER VOLUME, MUSIC MUTE, MUSIC VOLUME, MIC VOLUME, TEL VOLUME,
ALC controls (screwdriver-adjustable)
All models have thermal and electronic overload protection.
TPU35B: 1.0A, 120V AC circuit breaker; TPU60B: 1.6A, 120V AC circuit breaker;
TPU100B: 2.5A, 120V AC circuit breaker; TPU250: 6.0A slow blo fuse
(120V AC, 60Hz) TPU35B: 0.75A; TPU60B: 1.5A; TPU100B: 2A; TPU250: 5A
-4°F (-20°C) to 131°F (+55°C)
Black with silver lettering
TPU35/60/100B models: 14-3/16" W x 8-3/8" H x 3-5/8" D
TPU250: 19" W x 10-1/2" H x 3-13/16" D
TPU35B: 16 lbs.; TPU60B: 17 lbs.; TPU100B: 21 lbs.; TPU250: 31 lbs.
Architects The telephone paging amplifier shall be a Bogen Model ___,
and Engineers with a full power rating of ___ watts. (Specify: TPU35B/35
Specifications watts, TPU60B/60 watts, TPU100B/100 watts, TPU250/250
watts.) The amplifier shall provide a frequency response of
±1dB from 70Hz to 15kHz, and shall deliver rated power at
less than 1% distortion.
The amplifier shall permit paging from telephone and/or
microphone. The signal-activated paging channel shall automatically mute background music during a telephone page,
eliminating the need for manual activation of switches and the
use of external relays. Provision shall be included to set to
mute the level of background music during a page. Music level
shall be returned to its normal level after a page.
The telephone paging channel shall have a VOX sensitivity
adjustment to eliminate transmission of background noise,
and automatic output leveling (ALC) to compensate for varying voice levels and paging techniques of persons using the
system.
An Aphex® Aural Exciter circuit shall be included to regenerate the harmonics lost during the amplification process. A
control shall be provided to set the level of the Aphex effect.
A night ringer shall be included to alert personnel of incoming calls during non-business hours. The night ringer shall be
activated by a contact closure or by 90-volt ring signal from
the telephone line.
Input terminals shall be furnished for a telephone line and
LO-Z balanced microphone. A choice of RCA jack or screw
terminals shall be provided for the music source. Terminals
shall also be provided to control music muting during a mic
page, and for contact closure or ring signal activation of the
night ringer. Bridging jacks shall be provided to bridge two
TPU-series amplifiers.
Balanced or unbalanced outputs shall be provided for 16ohm, 25V, 25VCT, and 70V speaker lines. Provision shall be
included to feed a 600-ohm telephone line, LO-Z input or
balanced microphone input of another amplifier, using an
accessory line-matching transformer (Model WMT1A).
Individual controls shall be provided to set the telephone and
mic page volume, music volume, night ringer volume, VOX
sensitivity, and music mute level. Bass and treble controls shall
permit tonal adjustments. An automatic level control (ALC)
and VOX sensitivity controls shall be included. A peak level
indicator shall illuminate when the amplifier is driven into
clipping. A power indicator shall also be provided. The amplifier shall operate from a 120V AC, 60Hz source, and shall be
equipped with a resettable circuit breaker and thermal and
electronic overload protection (TPU250 has a 6A slow-blo
fuse).
Installation shall be facilitated by flanges with keyhole slots for
mounting on a suitable backboard. Dimensions for the 35, 60,
and 100 models shall be 14-3/16" W x 8-3/8" H x 3-5/8" D.
Dimensions for the TPU250 shall be 19" W x 10-1/2" H x 313/16” D.
50 Spring Street, Ramsey, New Jersey 07446
201-934-8500 FAX: 201-934-9832, www.bogen.com
Dukane Catalog u Commercial Sound Products
AM-FM Tuner/CD & MP3
Player with
Mixer/PreAmp
RCD350P
Overview
Standard Features
Dukane AM-FM Tuner/CD and MP3 Player with Mixer/PreAmp
is an auxiliary music and sound source for paging and intercom
systems. It can be installed in a standard 19 inch rack or as a
desktop unit by removing the rack mounting hardware.
CD Player
• Supports most common CD audio formats: including CD, MP3
and WMA
Application
• Three-band equalizer with six preset tone curves
Designed for use with Dukane StarCall and MCS350 Administrative Communications Systems, these units provide a single
channel output from one or all five inputs. A mixer/preamp
section selects and/or mixes up to four external inputs and one
internal source. The preamp section is equipped with a master
gain control and output level LED indicator. A monitor speaker
and volume level control are provided for input selection, cueing,
and level adjustment.
A master on/off switch with indicator controls unit power. A priority enable circuit allows giving one input priority over all others.
A bridging circuit is provided to increase the number of available
program sources. Both models combine a sensitive AM-FM
tuner with a CD player. Player includes input jack for MP3 player
interface.
Page 1 of 2
• Aux stereo input jack (3.5 mm) allows for playback of MP3
devices and their pre-recorded music or announcements
• Single line text LCD display with 8-character text
• MP3 ID3 Tag Display (Title, Artist, Album)- shows tuner band,
elapsed playback time, track number, type of disc, (when
repeat play and local seek tuning are activated) - displays time
when not in use
• Remote control for tuner included
Mixer/Preamp Unit
• Priority enable circuit
• Two low Z microphone inputs
• Two AUX inputs
• One bridge input
85100-0141
D ATA S H E E T
Not to be used for installation purposes. Issue 1
Specifications
Tuners
AM Tuner
Detection & alarm since 1872
FM Tuner
U.S.
T 800-385-2639
Canada
T 519-748-5352
F 519-748-9221
utcfireandsecurity.com
© 2010 UTC Fire & Security.
All rights reserved.
CD Player
WMA
(.wma)
WAV
(.wav)
MP3
(.mp3)
Disc
Frequency range selectivity: 530kHz to 1710kHz 40dB (+/–10kHz)
Maximum sensitivity: 14dB/mV (5mV at 0.5W)
Frequency range alternate channel selectivity: 87.9MHz to 107.9MHz 75dB
Usable sensitivity stereo separation: 15.2dBf (1.6mV, 75W) 35dB at 1,000Hz
50dB quieting sensitivity image response ratio: 17.2dBf (2.0mV, 75W) 50dB
Frequency response if response ratio: +/– 3dB 30Hz–15,000Hz 100dB
Capture ratio signal-to-noise ratio: 1.5dB 70dB
Encoded by Window Media Player
Bit rate: 48 Kbps to 320 kbps (CBR), 48 kbps to 384 kbps (VBR)
Compatible format: Linear PMC (LPCM). MS ADPCM
Quantization bits: 8 and 16 (LPCM), 4 (MS ADPCM)
Sampling frequency: 16 kHZto 48 kHZ (LPCM), 22.05 kHz and 44.1 kHz (MS
ADPCM)
Bit rate 8 kbps to 320 kbps
Sampling frequency: 16 kHz to 48 kHz (32,44,1,48 kHz for emphasis)
Compatible ID3 tag version: 1.0, 1.1, 2.2, 2.3, 2.4 (ID3 Tag Version 2.x is given
priority over Version 1.x;
M3u playlist: No;
MP3i (MP3 interactive), mp3 PRO: No
Playable folder hierarchy: up to eight tiers (A practical hierarchy is less than two
tiers) Playable folders: up to 99; Playable files: up to 999
File systems: ISO 9660 Level 1 and 2, Romeo, Joliet
Multi-session playback: Yes;
Packet write data transfer: No;
Regardless of the length of blank section between the songs of the original
recording, compressed audio discs play with a short pause between songs.
Overall Data
Power requirements +12Vdc, 700mA maximum
Inputs
2 low-impedance microphones, 2 auxiliary inputs, built-in AM/FM/CD/MP3
Player
Audio line output
3Vrms maximum
Controls (front)
POWER on/off switch, MASTER volume control, MONITOR speaker volume,
control, 5 source selector/mixer bank
Controls
Function, EQ/Loud, SCR/Off, Station Program Buttons (6). Eject (CD), Audio,
(AM-FM tuner/
Clock set, Disp/SCRL, Band/ESC, Curser ControlScan; Tuning (manual or
CD Player)
preset, five AM and ten FM preset stations available)
Controls (rear)
5 source preset input level adjustments, 1 monitor preset level adjustments, 1
bar graph level adjustment
Indicators/displays Master Power LED; Preamp output level bar graph
Terminations
Preamp out (screw terminal); Power (screw terminal); AUX (RCA pin jack); MIC
input (screw terminal); Bridge (RCA pin jack); Priority Enable Input and Output
(screw terminal); Antenna (F-81C female for RG59 coaxial cable, 75W)
Housing
Metal rack mount panel finished in textured charcoal-colored powdercoat. Can
be converted to tabletop.
Dimensions
19" (48.3 cm) wide x 3.5" (8.9 cm) high x 10.25" (26 cm) deep
When used as a table top configuration, the dimensions are:
14" (36 cm) wide x 2.75" (7 cm) high x 10.25" (26 cm) deep
Antenna termination F-81C female for RG59 coax cable 75 Ω
Wiring Preamp out Twisted pair, 22 AWG min.
Ordering Information
Model
RCD350P
RCD-RA
RCD-PS
Weight
11.7 lb (5.3 kg)
85100-0141
D ATA S H E E T
Not to be used for installation purposes. Issue 1
10-06-10
Page 2 of 2
Description
Rack mount AM/FM Tuner/CD Player and MP3 Player with pre
amp, Includes RCD-PS Power Supply.
Replacement rackmount adapter kit
Replacement +12V power supply
Universal Whip Antenna
BFK
NTS
07-Univ-Antenna
2007-06-01
9A10506200
Z
PD-D2610
FRANÇAIS
OWNER’S MANUAL
MANUEL DU PROPRIÉTAIRE
MANUAL DEL USUARIO
ENGLISH
Compact Disc Changer
ESPAÑOL
Name and Function
B
A
K
J
C
I
H
G
F
D
E
A POWER
Press this button to turn the unit on or off.
K
L
The equipment draws nominal non-operating power from
the AC outlet with its POWER switch in the OFF position.
O
D
P
B Disc tray
Q
C OPEN/CLOSE
R
M
N
G
F
T
S
U
E
Use this button to open and close the disc tray.
D DISC SKIP
Use this button to skip discs.
E PLAY (y)
Use this button to start playback.
F PAUSE (J)
Use this button to pause playback.
G STOP (H)
Use this button to stop playback.
H Skip/Search buttons
Use these buttons to skip or search tracks.
I Display
J Remote Sensor
When operating the remote control unit, point it towards the
remote sensor.
6
Remote Control Unit
K DISC NO.
Use these buttons to slect a disc.
L TRACK NO.
Use these buttons to select a track number.
For instance, to select track number 35, press “3” and “5”.
M PROGRAM
Use this button to enter the program mode. In program
mode, use this button to enter selections.
N SEARCH (m/,)
During playback, use these buttons to search the part you
want to listen to.
< Even if the remote control unit is operated within the effective
range, remote control operation may be impossible if there
are any obstacles between the unit and the remote control.
< If the remote control unit is operated near other appliances
which generate infrared rays, or if other remote control
devices using infrared rays are used near the unit, it may
operate incorrectly. Conversely, the other appliances may
operate incorrectly.
ENGLISH
O SHUFFLE
The provided Remote Control Unit allows the unit to be
operated from a distance.
When operating the remote control unit, point it towards the
REMOTE SENSOR on the front panel of the unit.
Battery Installation
Use this button for shuffle playback.
P TIME
During playback, use this button to change the time display.
Q REPEAT
Use this button to select repeat modes.
R INTRO CHECK
Use this button to start the intro check playing.
1. Remove the battery compartment cover.
S PROGRAM CHECK
Use this button to check programed contents.
T CLEAR
Use this button to clear a program.
2. Insert two “AA” dry batteries. Make sure that the batteries
are inserted with their positive “+” and negative “_” poles
positioned correctly.
3. Close the cover.
U SKIP (.//)
Use these buttons to skip tracks.
Battery Replacement
If the distance required between the remote control unit and
main unit decreases, the batteries are exhausted. In this case
replace the batteries with new ones.
Precautions concerning batteries
< Be sure to insert the batteries with correct positive “+” and
negative “_” polarities.
< Use batteries of the same type. Never use different types of
batteries together.
< Rechargeable and non-rechargeable batteries can be used.
Refer to the precautions on their labels.
< When the remote control unit is not to be used for a long
time (more than a month), remove the batteries from the
remote control unit to prevent them from leaking. If they
leak, wipe away the liquid inside the battery compartment
and replace the batteries with new ones.
< Do not heat or disassemble batteries and never dispose of old
batteries by throwing them in a fire.
7
Troubleshooting
Specifications
If you experience any problems with the unit, please take a
moment to look through this chart and see if you can solve the
problem yourself before you call your dealer or a TEAC service
center.
CD Player
Pickup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-beam laser
D/A converter . . . . . . . . . . . . . . . . . . . . . . . . Dual 1-bit linear
Digital filter . . . . . . . . . . . . . . . . . . . . . . 4-times oversampling
Frequency Response . . . . . . . . . . . . . . . 20 Hz - 20 kHz, ±2dB
Total Harmonic Distortion . . . . . . . . Less than 0.02 % (1 kHz)
Signal-to-Noise Ratio (S/N) . . . . . . . . . . . . . More than 100 dB
Channel separation . . . . . . . . . . . . . More than 85 dB (1 kHz)
Output . . . . . . . . . . . . . . . . . . . . . . . Analog: 2.1 Vrms (RCA)
Digital: COAXIAL/TOS OPTICAL
General
No power
e Check the connection to the AC power supply. Check and
make sure the AC source is not a switched outlet and that,
if it is, the switch is turned on. Make sure there is power to
the AC outlet by plugging another item such as a lamp or
fan.
Cannot play.
e Load a disc with the playback side facing down.
e If the disc is dirty, clean the surface of the disc.
e A blank disc has been loaded. Load a prerecorded disc.
e Depending on the disc, etc. it may not be possible to play
back CD-R/CD-RW discs. Try again with another disc.
e You cannot play back unfinalized CD-R/CD-RW discs.
Finalize such a disc in a CD recorder and try again.
Sound skips.
e Place the unit on a stable place to avoid vibration and shock.
e If the disc is dirty, clean the surface of the disc.
e Don’t use scratched, damaged or warped discs.
Remote Control Unit
Remote control doesn’t work.
e If the batteries are exhausted, change the batteries.
e Use remote control unit within an effective range (5m) and
point at the front panel.
e Clear obstacles between the remote control unit and the
main unit.
e If a fluorescent light is near the unit, turn it off.
ENGLISH
No sound
e Check the connection to the amplifier.
e Check the operation of the amplifier.
General
Power Requirement . . . . . AC 230 V, 50 Hz (European Model)
AC 120 V, 60 Hz (U.S.A./Canada Model)
Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 W
Dimensions (W x H x D) . . . . . . . . . . . . . 435 x 115 x 390 mm
(17 1/8” x 4 1/2” x 15 3/8”)
Weight (Net) . . . . . . . . . . . . . . . . . . . . . . 6.2 kg (13 11/16 lb)
Operating temperature. . . . . . . . . . . . . . . . . . . . +5˚C - +35˚C
Operating humidity . . . . . . . . . 5% to 85% (no condensation)
Storage temperature. . . . . . . . . . . . . . . . . . . . . –20˚C - +55˚C
Standard Accessory . . . . . . . . . . . . . . . . . . . . . . RCA cable x 1
Remote control unit (RC-1122) x 1
Batteries (AA) x 2
Owner’s manual x 1
Warranty card x 1
• Design and specifications are subject to change without
notice.
• Weight and dimensions are approximate.
• Illustrations may differ slightly from production models.
For European customers
Disposal of your old
appliance
MP3
There is no sound even if the PLAY button (y) is pressed.
e Non-playable file formats cannot be played.
Some unknown characters are displayed on the display
panel.
e This unit cannot display symbols and full-size or doublebyte characters (such as Japanese, Chinese, etc.) correctly.
File name of MP3 should be alphanumeric characters.
If normal operation cannot be recovered, unplug the
power cord from the outlet and plug it again.
1. When this crossed-out wheeled bin
symbol is attached to a product it means
the product is covered by the European
Directive 2002/96/EC.
2. All electrical and electronic products should be disposed of
separately from the municipal waste stream via designated
collection facilities appointed by the government or the
local authorities.
3. The correct disposal of your old appliance will help prevent
potential negative consequences for the environment and
human health.
4. For more detailed information about disposal of your old
appliance, please contact your city office, waste disposal
service or the shop where you purchased the product.
15
WebSchedule
Network Based Scheduling Solution
What is WebSchedule?
•
PC Window Application Software:



•
Schedules for events or bells.
Allows update, change, create schedules.
Runs on LAN
Web Manager for Multi-Facility:



Web Browser based to access scheduler.
Allows update, change, create schedules.
Interface over the WAN
WebSchedule
Systems Supported?
•
•
•
StarCall
MCS350
Various others (contact your dealer for more
info)
WebSchedule
Secured
Web Schedule
Application
Secured
Web Schedule
Application
Web Schedule
Application running
on local Windows PC
WAN
Web Schdule
Application running
on local Windows PC
Web Schdule
Application running
on local Windows PC
LAN
Event Relays
NETRLY4
Time Sync Relay
What features and benefits it
provides?
•
•
•
•
•
•
•
•
•
User does not need to know how to program system
via installer software to create or modify bell
schedules.
Multiple Bell schedules: Standard, Special, Holidays
etc.
Easy to create and manage one schedule across
multiple systems
Calendar based, allows you view or edit on fly.
Easy to use
Supports over 200 events/bells.
By date, day of week and time of day
Support and Access over LAN/WAN
Remote schedule set up and management
WebSchedule Edit Page
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: [email protected]
Model #: OMNIVS1500XL
OmniVS Series 1500VA Tower Line-Interactive 120V UPS with USB port and Extended-run options
Highlights
1500VA / 1.5kVA line interactive, tower UPS with extended runtime capability
Maintains 120V nominal output over an input range of 75V to 147V
Workstation optimized features include USB port, single line TEL / DSL or
Ethernet line surge suppression and two surge-only outlets
Input: NEMA 5-15P (120V 15A) / Output: 8 NEMA 5-15R (120V)
$200,000 Ultimate Lifetime Insurance (USA, Puerto Rico & Canada only)
3 year product warranty
Description
Tripp Lite's OMNIVS1500XL line interactive UPS system offers voltage regulation, surge suppression and long lasting, expandable battery support
for personal computers, internetworking equipment and other sensitive electronics. Internal UPS batteries support entry level PC systems for up to
75 minutes during power failures so that connected equipment can be shut down without data loss. Automatic Voltage Regulation (AVR) circuits
regulate brownouts as low as 75 and overvoltages up to 147 volts back to usable 120V levels without using battery power. Offers complete desktop
power protection in an attractive black tower configuration. Includes 6 battery supported outlets for computer, monitor and vital system peripherals,
plus 2 additional surge suppression only outlets for printers and other system accessories not requiring battery support. USB port enables optional
unattended system shutdown without data loss in the case of extended power failure (USB cable included). PowerAlert software available via free
download from www.tripplite.com. Built-in data line suppression offers protection for equipment with single line TEL/DSL or network Ethernet
connection. Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and
overload. 1500VA power handling ability supports entry-level PCs, network workstations, point-of-sale equipment, small business phone systems,
audio/video equipment and home theater systems. Offers 4.5 minutes battery runtime with a full load of 1500VA and 13 minutes with a half load of
750VA. Supports hot-swappable battery replacement via built-in access panel. Extended runtime available with optional BP24V15RT2U,
BP24V28-2U, or BP24V70-3U external battery packs.
Package Includes
OMNIVS1500XL Line Interactive UPS
USB and telephone cable
Owner's manual with warranty information
Features
OMNIVS1500XL Uninterruptible Power Supply offers voltage regulation, surge suppression and long lasting battery support
Supports entry level PCs up to 75 minutes during blackouts to enable shutdown without data loss
Regulates brownouts as low as 75V and overvoltages to 147V back to usable 120V nominal levels without using battery power
6 UPS battery supported outlets, plus 2 additional surge suppression-only outlets
USB port and cable enables UPS monitoring and unattended shutdown in the case of extended power failure
PowerAlert software available via free download from www.tripplite.com
Data line surge suppression protects standard dialup/DSL or Ethernet line connection
Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and
overload
1500VA power handling ability supports a variety of sensitive electronic equipment
4.5 minutes full load runtime (1500VA), 13 minutes half load runtime (750VA)
Runtime is expandable with the addition of external battery packs (SEE OPTIONS & ACCESSORIES)
Supports hot swappable battery replacement via built-in access panel
$200,000 connected equipment insurance (USA, Puerto Rico & Canada Only)
3 year warranty
Specifications
OUTPUT
Output Volt Amp Capacity
(VA)
1500
Output kVA capacity (kVA)
1.5
Output Watt Capacity
(watts)
940
Nominal Output Voltage(s)
Supported
115V; 120V
Frequency compatibility
60 Hz
Output voltage regulation
(line mode)
-18%, +8%
Output voltage regulation
(Battery mode)
115V (+/- 5%)
Built-in UPS output
receptacles
8 5-15R outlet(s)
Surge suppression only
outlets
6 UPS outlets, 2 surge-only outlets
Basic PDU options
PDU1215 (1U / 13 5-15R outlets); PDUNV (1U / 2 C19, 12 C13 outlets); PDU1415 (0U / 14 5-15R outlets);
PDUV15 (0U / 12 5-15R outlets)
Metered PDU options
PDUMH15 (1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*; PDUMV15 (0U / 16 5-15R outlets)
Switched PDU options
PDUMH15ATNET (1U / 8 5-15R outlets)*; PDUMV15NET (0U / 16 5-15R outlets)
External PDU redundancy
options
*Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS
models only
Output AC waveform (AC
mode)
Sine wave
Output AC waveform
(battery mode)
PWM sine wave
INPUT
Rated input current (at
maximum load)
12A
Nominal Input Voltage(s)
Supported
120V AC
UPS input connection type
5-15P
UPS Input cord length (ft.)
6
UPS Input cord length (m)
1.8
Recommended Electrical
Service
15A 120V
BATTERY
Full load runtime (minutes)
4.5 min. (940w)
Half load runtime
(minutes)
13 min. (470w)
Expandable battery
runtime
Extended runtime supported via optional external battery packs
External battery pack
compatibility
BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)
DC system voltage (VDC)
24
Battery recharge rate
(included batteries)
Less than 4.5 hours from 10% to 90%
Replacement battery
cartridge (internal UPS
battery replacement)
RBC51 (quantity 2)
Battery Access
Battery access door
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Overvoltage correction
Input voltages between 128 and 147 are reduced by 12%
Undervoltage correction
Input voltages between 93 and 107 are boosted by 14%
Severe undervoltage
correction
Input voltages between 75 and 92 are boosted by 30%
LEDS ALARMS & SWITCHES
LED Indicators
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Alarms
Audible alarm indicates power-failure and low-battery conditions
Alarm cancel operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
690
UPS AC suppression
response time
Instantaneous
UPS Dataline suppression
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form factors
supported with included
accessories
Tower
Installation form factors
supported with optional
accessories
Wallmount (UPSWM - tower mounting kit)
Primary form factor
Tower
UPS / Power Module
dimensions in primary
form factor (height x width
x depth / inches)
11.8 x 7.2 x 7.5
UPS / Power Module
dimensions in primary
form factor (height x width
x depth / cm)
29.8 x 18.4 x 19
UPS / Power Module
weight (lbs)
28
UPS / Power Module
weight (kg)
12.7
UPS Shipping dimensions
(height x width x depth /
inches)
15.5 x 11 x 11.2
UPS Shipping dimensions
(height x width x depth /
cm)
39.4 x 27.9 x 28.6
Shipping weight (lbs)
30
Shipping weight (kg)
13.6
UPS housing material
Polycarbonate
Cooling method
Fan
ENVIRONMENTAL
Operating Temperature
Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature
Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr. (full
load)
355.1
Battery mode BTU / hr.
(full load)
477.6
COMMUNICATIONS
Communications interface
USB
PowerAlert software
Free download from www.tripplite.com
Communications cable
USB cable included
WatchDog compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
2-4 milliseconds
Low voltage transfer to
battery power (setpoint)
75
High voltage transfer to
battery power (setpoint)
147
SPECIAL FEATURES
Cold Start (startup in
battery mode during a
power failure)
Cold-start operation supported
High availability UPS
features
Hot swappable batteries
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B
(EMI)
WARRANTY
Product Warranty Period
(U.S., Canada & Puerto
Rico)
3-year limited warranty
Connected Equipment
Insurance (U.S., Canada &
Puerto Rico)
$200,000 Ultimate Lifetime Insurance
Related Items
Optional Products
Product Type
Related Model
Description
Qty.
USB Hubs/Accessories
U022-010
10-ft. USB2.0 A/B Gold Device Cable
(A Male to B Male)
-
Wallmount Bracket
UPSWM
Wallmount Bracket and installation accessories (4 washers, 4 screws,
1 Velcro safety strap)
-
Software
WATCHDOGSW
WatchDog Service Monitoring / Reboot Software
-
Surge Protectors
DTEL2
Network Surge Suppressor - Essential protection for data and
communication lines
-
Surge Protectors
DNET1
Network Surge Suppressor - Essential protection for data and
communication lines
-
Extended Warranties
WEXT5-OMNI
5-Year Extended Warranty - For OmniSmart, OmniPro, OmniVS
-
External Battery Packs
BP24V15RT2U
BP24V15RT2U - External Battery Pack for UPS System
-
External Battery Packs
BP24V28-2U
BP24V28-2U - External Battery Pack for UPS System
-
External Battery Packs
BP24V70-3U
BP24V70-3U - External Battery Pack for UPS System
-
More information, including related products, owner's manuals, and additional technical specifications, can be found online at
www.tripplite.com/en/products/model.cfm?txtModelID=2730.
Copyright © 2011 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous
improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.
Sound & Paging Equipment
CALL STATION
PCGS-25-MP
FLUSH MOUNTING TYPE
FEATURES:
C
Baked Epoxy Finish, Bone White
C
Heavy Gauge Steel Construction
C
Hidden Speaker Mounting Studs
C
Excellent Vandal Resistance
DIMENSIONS:
SPEAKER SPECIFICATIONS:
C
12 ½" Square, 1 ½” deep , 11" mounting
Centres. Fits Standard MC20E Back
Box.
C
8" Diameter
C
6 oz Magnet Weight
MCS - Call Switch
C
60-14kHz Frequency Response
C
Momentary
C
1" Voice Coil Diameter
C
Normally Open
C
Impedance - 8 Ohms
C
Pigtail Leads
C
Sensitivity (1W/ 1M)93dB
C
10 Watts/RMS
C
Depth 2 3/4"
PRIVACY
C
Clearly Annunciates System, Supplied
Privacy Tone
EMT501 & EMT501B
Ceiling Speakers
Corridor Speakers
Key Features:
u
5.5 inch woofer
u
Power selector terminal on rear
u
Snap in mount for easy installation
u
Modern design
u
All metal construction
u
Optional Supports
u
Optional HA501 Hole Saw
Description
The EMT501and EMT501B ceiling speaker is designed to meet the needs for background music and paging. The EMT501 &
EMT501B incorporates a 5.5 inch speaker to ensure smooth, clear response.
The EMT501and EMT501B is all metal construction to ensure maximum durability. Power is chosen using the convenient screw
terminal on the rear. The spring loaded mounting clips guarantee fast and simple installation. Using the optional HA501 Hole Saw,
it will cut installation time to an absolute minimum.
This simple yet effective approach to background music and paging system
speakers saves both time and money providing a very astatically pleasing look which appeals to even the most discerning of designer.
Specifications
Type : EMT Series Ceiling Speaker
Driver : 5.5” full range
Power Taps (25/70 V) : 4w, 2w, 1w, 0.5w
Power Handling Direct : 15 watts
Sensitivity (1W/1M) : 87 dB
Frequency Range : 50/20kHz
Rated Voltage
: 70 volts, 25 volts, 8 ohm
Dimensions (dia x depth) EMT 501:
7.875”
200 x 75mm (7.875 inches x 2.75 inches)
Dimensions (dia x depth) EMT 501B :
200 x 75mm (7.875 inches x 3.78 inches)
6.5”
Cut out mounting diameter :
3.78”
165mm (6.5 inches)
Finish : White paint on metal
2.75”
EMT 501
EMT501/B
EMT 501B
white radio
a cygnal technologies company
EMT501 & EMT501B
Ceiling Speakers
Polar Curves
EMT501:
EMT501B:
Frequency Response
EMT501:
EMT501B:
Optional Supports
EMTBS
T-Bar Support
white radio
a cygnal technologies company
EDR501
Dry Wall Rough-in
ESR501
Dry Wall Support Ring
EMT501/B
T-Bar Supports
ETBS
ETBS
24" T-bar supports can be used on their own or
with any standard back box to provide tile support
for speaker baffles installed in drop ceiling tile.
ETBST
T-Bar support 24" length for use with torsion
mount baffles when not using a back box.
Tile Bridge
ETBST
ETBSU
ETBSU
The universal tile support saves time and money
when installing ceiling speakers that do not
require a back box. It will work easily with any
speaker baffle designed for an 8" speaker whether
it is round, square, torsion or standard four hole
mounting. This 24" tile support is easy to install.
ETBST
ETBST
This tile support is the same as the ER800
however the ETBS bar supports are attached. It is
a one piece unit built for a speedy install when a
back box is not required.
ETBS502
24" one piece tile support
for use with EPCS502B speaker systems.
ETBS502
Enforcer Sound- Square / Round Surface Back Boxes
EBB-Flush Back Boxes
EBB8SF
Enforcer flush mount back boxes are of an all
metal welded construction. They are all
made from 23 gauge metal and have an acoustic
damping material inside.
The EBB8RFS is a stackable one piece back box. In
addition to being very easy to handle these
stackable back boxes take far less room to store
and will save you money in shipping costs.
Product Specifications:
EBB4SF/RF
z Available in a no mess finish - much
better for handling.
z Acoustic damping on all models.
z Available in a variety of depths to
meet installation needs.
z Both torsion as well as standard 4 hole
baffle mounting.
z Stackable - saves time plus shipping
costs.
Comparison Chart
EBB8RF2
EBB8RF7D
For classroom stations, and gym ceiling speakers
Nurse Call
Part of GE
Security
CENTRAL EQUIPMENT
Compatibility Î
|
StaffCallPro
Pull cord stations and interface
PTM Series, PUM01-B-D Maxi-use module
Features
Pull Cord Stations
„ Mount to one-gang electrical boxes
„ Manually resettable
„ 5' (1.5 m) nylon cord with white ABS pendant
„ Red LED indicator lamp
PTM03-C
Pull cord
Code Blue
station.
PTM01-C
Pull cord
emergency
station.
Maxi-use Module
„ Interface between passive peripherals and the master station
„ Compatible with smoke detector relays and security contacts
„ 32 inputs, 14 outputs
Application
Description
Emergency pull cord stations are sturdy call points designed to initiate
high priority calls. Emergency and Code Blue models are available. All
models feature a strong nylon cord for easy access from any height,
and an on-board LED provides instant visual confirmation that the call
has been placed.
The Maxi-use module is the interface that ties passive devices to a
particular event on the system. It may be used to register at the master
nurse station the status of individual call points, buttons, or relays, and
to activate associated dome lamps and other devices in response to a
change in status of one or all of its connected devices. The Maxi-use
module accommodates up to 32 inputs, converting each to a 2-byte
coded message, and 14 programmable outputs.
The Maxi-use module and connected peripheral devices serve many
purposes. As a supplement to bedside communication between the
master nurse station and patient stations, emergency pull cord stations
are typically installed in the patient’s bathroom: one in the shower and
one near the toilet or sink. Similarly, Code Blue stations and 1-gang call
stations may be installed anywhere there is a chance that staff or
patients require immediate assistance.
Fire alarm devices are also supported by the Maxi-use module. When
the relay output of smoke detectors or fire alarm pull stations are
connected to the module’s inputs, activation of the device can be
programmed to automatically generate a priority 1 FIRE call to the
master nurse station (this is for ancillary use only and is not a substitute
for code-compliant fire alarm annunciation). IV monitors, door stations
and many other contact-closure devices can be similarly configured to
operate as addressed calls with the Maxi-use module.
Maxi-use module visual display output capability is equally powerful.
Outputs to dome lamps generate coded visual signals that depend on
the nature of the input and its programmed priority.
Master
Station
Display
CODE
FIRE
EMERG.
BATH x
DOOR
ALARM
SHOWER
Call Type
Code blue (99)
Fire alarm
Emergency call
Bath emergency station
Open door alarm
Alarm device activated
Shower switch activated
Priority
1
1
2
3
3
3
3
Corridor Dome Lamp
Color
Red
Red/White
Red
White
White
Red
White
Flash Rate
Fast
Alternate
Slow
Fast
Fast
Slow
Fast
www.gesecurity.com
imagination at work
27545 DIEHL ROAD, WARRENVILLE, IL 60555
P H O N E : 630-836-3700 • F A X : 630-836-3800
CANADIAN OFFICE: 560 PARKSIDE DRIVE, UNIT 401,
WATERLOO, ON N2L 5Z4
Literature Sheet #85100-0026 Issue 1
Not to be used for installation purposes. Page 1 of 2
75 Years of Excellence
VPCS-2GPB-X45
VPVT-PB
VPB-1A
VP-77
WPVT-4FN
Vandal-Proof Intercom Stations
Stations with Cone Loudspeaker & Call Switch Option
Plate-Mounted Call Switch
VPB-1A. Intercom accessory includes a vandal-resistant push button mounted to an all new single-gang, 12-gauge
stainless steel plate which may be used in conjunction with VPV TPB, VPCS-2G-2(PB) and VPCS(PB) Series intercom
stations. Switch may also be used as a stand alone signaling device when a separate or remotely located callorigination button is desired. Switch is a SPST normally open circuit with a 3-amp contact rating. Hardware installs
using a 6–32 holt-head driver bit for a standard 1⁄4 " nut driver.
Stations with Compression Driver & Call Switch Option
VPV T-4PB Series. Loudspeaker station with high-efficiency compression driver mounted to a 12-gauge stainless
steel plate provides two-way communication for vandal-proof use in detention facilities, correctional institutions, and
secured access applications. Rugged recess-mounting assemblies incorporate the patented V T Series, environmentresistant compression driver; recognized throughout the world for dependable performance and effective voice and
signal tone distribution. High-intelligibility, 8Ω compression driver also functions as a microphone to provide clear
voice communication. VPV T-4PB incorporate a vandal-­r esistant call-origination button with 3 amp contact rating to
provide call-in signaling capability. Station available in high-power 15 watt models with 25V transformer. VPV T-PB
Series measures 71⁄4 " square and installs into VP-77 backbox. Backboxes are ordered separately.
Recessed Backbox for Vandal-Proof Stations
VPV T-4PB. Protective backbox is constructed of 16-gauge CRS and finished in black textured enamel for installation
of specified vandal-proof loudspeaker station assembly.
Stations with Compression Driver and Call Switch
WPV T-S / WPV T-F Series.. Surface and flush-mounting outdoor intercom and paging loudspeaker assemblies
provide weatherproof and vandal-proof two-way communication with call-in capability for remote guard and security
stations, entry and exit gates, perimeter doors and parking garages.
Environment-resistant assemblies include die-cast water sealed V T Series 8Ω compression driver loudspeaker
­a vailable with 15 or 2 watt transformer and pre-mounted call SPDT-type switch protected by a weatherproof rubber
boot. WPV T-S Series are surface mounting assemblies size 4 1⁄4 " Square x 3 1⁄8 " Depth. WPV T-F Series are recess /
flush-mounting versions size 6" Square x 3 3⁄16 " Depth. Both model series are finished in neutral gray(N) epoxy and
install to a standard 4" E.O. Box (not included). A large selection of installation accessories are also available. See
Installation Accessories for Voice / Tone Loudspeakers page xx.
AtlasSound.com
71
Vandal-Proof Intercom Stations
VPCS Series. High-security vandal-proof loudspeaker stations are equipped with a 2 1⁄2 " diameter moisture-proof resin
impregnated cone loudspeaker for clear voice / signal transmission with durable performance. The overall depth of
all units is a shallow 2 1⁄8 " (54mm) allowing installation in standard size E.O. boxes. VPCS-2G Series and VPCS‑2GPB
are 2-gang versions. VPCS-3GPB-245 is a 3-gang model. All models include a two-piece die-cast barrier (patent
pending) to protect the loudspeaker assembly from vandalism. Models with “PB” designation include a vandal-proof
call switch. The switch is a heavy-duty, momentary action push-button with a 1.5A 250VAC contact rating. The 25V
transformer has .25, .5, 1 & 2 watt taps.
Model
Frequency
Response
SVT-27UCS
Model
500Hz -5000Hz (±5dB)
Power Taps
Frequency
Response
Sensitivity
>190˚ (-6dB point, 1 and 2kHz
octave bands)
Sound Level
Dispersion
96.9dB (1 watt, 1 meter)
UL: 90dB (1 watt, 10 ft)
Impedance
VTB-1
15 watts
400Hz – 4kHz
107dB
150˚
8Ω
VTB-2
15 watts
400Hz – 4kHz
107dB
150˚
4Ω
VTB-4
2, 4, 8, & 15
watts
400Hz – 4kHz
107dB
150˚
25V
VTB-6
1 & 2 watts
400Hz – 4kHz
100dB
Model
Series
UL
UHT
Model
Speaker /
Transformer / Cap /
Baffle
Size
8"
(203mm)
1480
UL
Transformer
10 oz
(283 g)
25V
1
UHT25C-U161-8
1480
25V
1
UHT70C-U51-8
1480
70.7V
1
UHT70C-U161-8
1480
70.7V
1
HPG-100N
Model
AS-100N
Model
Rectangular
Molded Bell
Power
Rating
Power
Rating
100 watts
Impedance
100 watts
DC Blocking
Capacitor
Tip Assembly-Gray
EST-527
ESB-974
Impedance
10 watts
8Ω
51-8 (Round)
95-8, 96-8
⁄2, 1, 2, 5
10 mfd @ 50V
51-8 (Round)
95-8, 96-8
⁄2, 1, 2, 5
4 MD @ 150V
161-8 (Square)
198-8, SE175-4
⁄2, 1, 2, 5
4 MD @ 150V
161-8 (Square)
198-8, SE175-4
Sound Level
Peak (dBA)
Finish
Dispersion
110dB
120dB
80˚ H x 105˚ V
Plane Wave
Freq. Response
Low Freq. Limit @
Full Power
100Hz – 2.5kHz (±5dB)
400Hz
Mounts
31⁄4" Length
AS-100N
Tip Assembly-Gray
51⁄4" Length
AS-100N
Loudspeaker Bell-Gray
5 ⁄2" Diameter x 3" Depth
AS-100N
1
K-100N
Replacement Head Assembly
—
YDA-TH
Dual Driver Adapter 13⁄8"-18F,
13⁄8"-18M thread
—
HPG100N
AS100N
Description
Dimensions
25V; 2-Gang
43⁄4" Square (121mm)
21⁄8" Depth (54mm)
VPCS-2GPB-2
25V; 2-Gang w/ Call Switch
43⁄4" Square (121mm)
21⁄8" Depth (54mm)
VPCS-3GPB-245
25V; 3-Gang w/ Call Switch
Width 63⁄8" (162mm)
Height: 43⁄4" (121mm)
Depth: 21⁄8 (54mm)
VPCS-2G-2
Model
VPB-1A
Model
VPVT-4PB
Description
Width
Plated Mounted 1-gang Call
Switch
Power Rating
Transformer
Height
23⁄4" (70mm)
Frequency
Response
41⁄2" (114mm)
Call Switch
Depth
13⁄8" (35mm)
Optional Back
Box
15 watts, 25V
25V
—
Width
Height
Depth
Mounts
VP-77
51⁄2" (139.7mm)
61⁄4"
(158.75mm)
31⁄2" (88.9mm)
VPVT-PB
Series
Model
Power
Rating
WPVT-1SN
15 watts (8 Ω)
—
600Hz – 5.5kHz
-26dBm
WPVT-4SN
15 watts
25V
600Hz – 5.5kHz
-26dBm
Model
146
Transformer
Yes
Frequency
Response
10,600
Gauss
Black Bell
Black Driver
HPG100N
AS100N
Model
Flux
Density
Mounts
Enclosure
(Order
Separately)
Baffle
Type
10 mfd @ 50V
Size
EST-510
25V
Power
Rating
⁄2, 1, 2, 5
11 Ω (nominal)
Description
85Hz – 8kHz
±5dB
Transformer
Taps
1480
Description
150˚
Frequency
Response
Magnet
UHT25C-U51-8
Model
Specifications
Dispersion
VP-77
Sensitivity As
Microphone
800.876.3333
Sound
Level
117dBa
Sensitivity
97dB
(1 W / 1 M)
Product
WT-201A
Miniature Pendant Transmitters
The WT-201A miniature 12-bit pendant transmitter designed for emergency and remote control applications in wireless security and
remote control systems.
When activated, the WT-201A transmits a 12-bit message, selected by an internal DIP switch from 256 possible combinations. To
assure reliable operation, an LED lights during transmission indicating that the battery is in good condition. An easy-to-use 4-channel
selector enables users to program the transmitter to activate any one of the receiver's four outputs.
For maximum wearing flexibility, the WT-201A pendant is supplied with a neck-chain and a key-ring clip.
This comfortable and attractive miniature pendant is compatible with Visonic wireless receivers of the WR-200 and WR-300 series
and other 12-bit devices. It is available in two frequency bands to comply with international standards, and are approved for use in
most countries.
WT-201A Features:
l Single button programmable to activate any one of the receiver's 4 outputs.
l Comfortable miniature attractive design.
l Superior transmission range.
l 12 V standard alkaline battery.
l Visible low battery indication.
l Neck-chain and key-ring wearing accessories included.
l Available in two optional frequencies in compliance with international standards.
l Compatible with all Visonic WR-200/WR-300 wireless receivers and 12-bit wireless devices.
Product
WR-200
Single-Output 12-Bit Wireless Receiver
The WR-200 is a single-output wireless receiver operating in conjunction with a wide variety of Visonic 12-bit wireless devices,
including portable and door/window transmitters, motion, glass-break and smoke detectors, coded keypads and range-extending
repeaters. Designed for security, alarm and control applications, the WR-200 is easily integrated into virtually any security and
remote control system.
To ensure secure wireless communication, the WR-200 receiver only responds to transmitters that transmit the same system code.
Users select a system code from 256 possible combinations, and quickly apply it system-wide, using the 8-position DIP switch on
each device.
A special "channel selector" enables setting the receiver output to respond to one of four possible communication channels of the
transmitters. Each channel may be used for any type of alarm: emergency call, motion, glass-break, smoke, etc. If the correct
system code and communication channel are detected, the WR-200 activates its relay output.
The WR-200 wireless receiver is available in two optional frequencies in compliance with European, U.S. and other international
standards, and is approved for use by local authorities in most countries.
WR-200 Features:
l Designed for security, alarm and control applications.
l Easily integrated into virtually any alarm control panel.
l Secure communication with transmitting device based on user-defined system code (selected from 256 possible
combinations).
l 4-channel selector for maximum control flexibility.
l 11-14 Volt DC or AC power supply.
l Available in two optional frequencies in compliance with international standards.
l Supports the complete variety of Visonic 12-bit wireless devices.
D225 and D400 DIGITAL
SECONDARY CLOCKS
D225 Digital Clock
D400 Digital Clock
Shown with Corridor Kit
NATIONAL TIME offers a digital clock series with improved features over previous models. This new microprocessor based secondary clock and the MC-100 Master Clock
form a unique time keeping system offering on demand time
correction. This digital communication format can provide
power and instantly correct all secondary clocks to any
time of day using only two conductor low voltage wire. This
format eliminates costly battery replacement and lengthy
reset schemes. National's new energy saving power algorithm and current control circuitry combine to provide a low
current, constant brightness LED display. 24VAC units are
available in attractive 4" or 2.25" high visibility, wide-bar
digits. For extremely long wire runs, 120VAC power and
communication may leave the Master Clock when the
appropriate 24VAC transformer is mounted at each clock or
double face unit.
For systems not utilizing National's Master Clocks, 12-hour
resets may be accomplished with a short power interruption
each 12:00.
The durable steel housing, plug-in connectors and universal
mounting plate simplify installation. An optional low profile
surface box allows for surface mounted conduit entry. The
corridor conversion kit will support top or side mounting,
single or double face. Powder grey finish standard, other
colors upon request.
FEATURES
On-Demand Correction
2-Wire Operation
Accurate 60hz Timekeeping
Low Power Consumption
Long-Life Sealed Display
Microprocessor Based
Durable Steel Housing
HighVisibility
Plug-in Connectors
BULLETIN C-419 07/03
Mounting Options
Box By Others
(Single,4"Square,Double)
D400 w/ D3T xmr
requires Deep
Boxes.
DxM-SURF BOX
for Conduit Entry
DxT-120/24 for 120VAC
applications
Flush Mount
Surface Mount
Fig. 1
DxT-120/24 for
120VAC applications
Fig. 2
4"Square, securely
mounted
Single Face/
Top Mount
Fig. 3A
Double Face/
Side Mount
Double Face/
Top Mount
Fig. 3B
Single Face/ Side
Mount Not Shown
Fig. 3C
For extra protection,
see our Clear-View Digital Clock
Protector. Bulletin C-417
Specifications
Voltage Requirements:
PART # VOLTAGE
RANGE
D225
24VAC
16-32VAC
120VAC 105-132VAC
D400
24VAC
16-32VAC
120VAC 105-132VAC
Current
57mA
15mA
85mA
30mA
24VAC: Clocks will function with 24VAC with no modifications.
120VAC: Supported with addition of these transformers:
D2T-120/24 - Supports Single Face D225
D3T-120/24 - Supports Double Face D225; Single or Double Face D400
The transformer mounts to the back of the mounting plate and extends into the surface box or electrical box. The D2T-120/
24 protrudes 1.18", the D3T-120/24 protrudes 1.75". (May require a Deep Double Gang or Deep 4 Square backbox or the
D4M-SURF BOX.)
Correction Formats Supported:
On Demand Correction: When used with National Time MC-100 Master Clock, clocks can correct to any time of day. Only
2 low voltage wires required.
12 Hour Reset: An 'off' pulse (0.5 sec. min) at 12:00 will reset all clocks.
Ordering Info
Part #
D225
D400
D2M-SURF BOX
D4M-SURF BOX
D2M-CORR KIT
D4M-CORR KIT
D2T-120/24
D3T-120/24
Fig
1
1
2
2
3
3
-
Description
2.25" Digital Clock with Mounting Plate
4" Digital Clock with Mounting Plate
Surface Mount Box for D225
Surface Mount Box for D400
D225 Corridor Conversion Kit; Side or Top Mount*
D400 Corridor Conversion Kit; Side or Top Mount*
120/24VAC Transformer for Single/Double Face D225
120/24VAC Transformer for Single/Double Face D400
Mounting
4 Square, Double, Single
4 Square, Double, Single
4 Square, Single,W all Surface
4 Square, Single,W all Surface
Securely mounted 4 Square
Securely mounted 4 Square
4 Sq, Dbl Gang,Surf/Corr. Box
D2M Corridor Kit
Dim A
10.13
16.88
10.13
16.88
5.00
5.00
-
B
5.06
7.13
5.06
7.13
6.30
8.44
-
C
1.13
1.38
2.63
3.38
3.75
4.75
-
D
11.40
18.20
-
*Clocks and Transformer (if necessary) Sold Separately.
PHONE (248) 380-6264 FAX (248) 380-6268
28045 OAKLAND OAKS CT.
WIXOM, MI 48393
DIGITAL CLOCK
PROTECTIVE GUARD
CV-GUARD-S
NATIONAL TIME now offers a digital clock
protective guard superior to other models. Manufactured with heavy duty 18 gauge steel, this
guard will stand up to the most demanding installations. The tough polycarbonate window provides obstruction-free viewing of the clock not
found in wire guard versions.
The Semi-flush Clear-View Guard will protect
up to a 4" digital clock when installed using a
flush mounted electrical box.
The Surface Clear-View Guard is used when a
surface mount enclosure such as D4M-SURF
BOX is used. (See Bulletin C-394) This deeper
guard has a slot centered on one side to accommodate surface conduit or other surface mount
wire raceways.
The guards are finished with Powder Gray paint
to match the standard digital clock finishes.
Other colors are available upon request.
CV-GUARD-F
FEATURES
Durable Welded Steel Housing
Tough Polycarbonate Window
Obstruction-Free Viewing
Surface and Semi-flush Models
Protects up to 4" Digital Clock
Easy Installation
BULLETIN C-417 10/02
Dimensions
Model CV-GUARD-S
Shown covering D2M
with D2M-SURF BOX
Model CV-GUARD-F
Shown covering D4M
Appropriate mounting hardware for
wall construction type required
Ordering Info
Part #
CV-GUARD-F
CV-GUARD-S
Description
Clear View Guard for up to 4" Semi-Flush Digital Clocks
Clear View Guard for up to 4" Surface mounted Digital Clocks
PHONE (248) 380-6264 FAX (248) 380-6268
28045 OAKLAND OAKS CT.
WIXOM, MI 48393
Rotary Drive
Wall Clocks
Case Style FR
Round
NATIONAL TIME is pleased to reintroduce the impulse
time system- with today's high tech performance!
Microprocessor technology has replaced the slow,
troublesome spring/ratchet/solenoid engagement designs
currently offered by other manufacturers.
National's revolutionary Rotary Drive time system can
instantly correct all of the building clocks to the exact hour
and minute at any time of the day! With our on demand
instant time correction, you no longer have to wait up to
twelve hours or perform confusing, tedious sequences of
manual stops, starts and resets. We give you the correct
time when you need it --- NOW! For systems not
incorporating the National MC100, On-Demand correction
may be achieved using the PS-3-OD Power supply or URTOD-HH module. See C-429 and C-434.
Rotary Drive guarantees to outperform all existing clock
technology without sacrificing the unsurpassed durability
you have come to expect from National Time's synchronous
motor drive systems.
The 3WS series will emulate most existing synchronous
clock operation without the frailties of solenoids, ratchets,
switches or levers. See Compatibility List bulletin C-430.
Each clock is equipped with an all metal case, convex
glass crystal, and white polystyrene dial having black
markings and hands. A sway-proof hanger plate is
furnished that securely holds clock to wall. Cases are
attractively finished in Powder Gray enamel. Other
finishes and shatterproof lens are available upon request.
Shatterproof lens now standard on 12” round.
Refer to Bulletin C-323 for classic dial series.
Case Style FQ
Square
FEATURES
Revolutionary Rotary Drive
Design
Microprocessor Controlled
On-Demand Instant
Correction
Universal Reset Operation
Swift, Smooth, Ratchet-free
Operation
Compatible with Existing 2 & 3
Wire Minute Impulse Systems
Compatible with Existing 3Wire Synchronous Clocks
BULLETIN C-332 rev.B
Ordering Information and Specifications
Surface Mount Clocks
Flush
Mount
Dial Size
10" Round
12" Round
12"Square
16"Round
24" Round
Dim A
Outside
Dia.
11-1/4"
13"
12-1/2"
16-1/2"
24"
Dim B
Box top to
Clock Top
2"
3-1/4"
2-3/4"
4-3/4"
8"
Surface
Mount
Dial Size
10" Round
12" Round
12"Square
16"Round
24" Round
Dim A
Outside
Dia.
11-5/8"
13-7/16"
12-1/2"
17"
24"
Dim B
Box top to
Clock Top
1-1/8"
13/16"
5/8"
3/4"
11/16"
SR-12RD-2WS-03-SP Analog Clock
DR-12RD-2WS-03-SP Double faced analog clock
Ordering Information
Case Style
Size
S=Surface
D=Double Face
Shape:
R=Round
Q=Square
Model No.
2W I-00
3W I-00
2W S-03
3W S-00
Part No.
D2T-120/24
D4T-120/24
Insert Model number from below
SR-12RD-MODEL NO.-SP
Rotary Drive
Movement
SP= Shatter-Proof convex crystal
(Leave Blank for Standard Glass)
-SP now standard on 12” Round
Description
2-W ire Impulse; 24VDC; Reverse Polarity; On Demand resets
3-W ire Impulse; 24VDC; On Demand resets
2-W ire Sync hronous; 24VAC; On Demand Resets; 12:00am/pm resets
3-W ire Sync.;24VAC; On Demand resets or 59th or 00 minute Synchronous Compatible
120VAC to 24VAC Transformer for Single Fac e 2W S or 3W S Clock
120VAC to 24VAC Transformer for Double Face 2W S or 3W S Cloc k
See Bulletin C-430 For Compatibility List. Consult Factory for other reset Compatibilities or Custom protocols
Compatibility: May be used in-line with existing clock types. On Demand resets require National’s Master. On synchronous
systems, On Demand resets will not effect existing clocks. On impulse systems, existing impulse clocks cannot
occupy the same circuit if On Demand resets are desired.
Synchronous Resets: 8 second hour, 14 second 12hr; 25 second hour, 25 minute 12hr; 2 second 12hr; 55 second
hour. See C-430 for compatibility list.
Operating Voltage: 24VDC versions:19-32VDC @ 150mA; Filtered DC supply required for 24VDC On Demand resets.
24VAC versions: 16-28VAC @ 3.8W;
120VAC versions 102-132VAC @ 3W (Require D2T-120/24 or D4T-120/24 Transformer)
U.S. Patents 5,282,180; 5,442,599; Patents Pending
PHONE (248) 380-6264 FAX (248)380-6268
21800 WYOMING AVE. OAK PARK, MI 48237-3195
TC Series Models c/w Heavy Duty Bracket Mounting and Terminals
Primary Sec.
Volts
Volts.
25VA
50VA
75VA
100VA
150VA
120
24
TC2524-1
TC5024-1
TC7524-1
TC10024-1
TC15024-1
-
120
TC25120-1
TC50120-1
TC75120-1
TC100120-1
TC150120-1
208
24
TC2524-2
TC5024-2
TC7524-2
TC10024-2
TC15024-2
-
120
TC25120-2
TC50120-2
TC75120-2
TC100120-2
TC150120-2
240
24
TC2524-3
TC5024-3
TC7524-3
TC10024-3
TC15024-3
-
120
TC25120-3
TC50120-3
TC75120-3
TC100120-3
TC150120-3
277
24
TC2524-4
TC5024-4
TC7524-4
TC10024-4
TC15024-4
-
120
TC25120-4
TC50120-4
TC75120-4
TC100120-4
TC150120-4
-
120/240 TC25120D-4 TC50120D-4 TC75120D-4 TC100120D-4 TC150120D-4
347
24
TC2524-5
TC5024-5
TC7524-5
TC10024-5
TC15024-5
-
120
TC25120-5
TC50120-5
TC75120-5
TC100120-5
TC150120-5
-
240
TC25240-5
TC50240-5
TC75240-5
TC100240-5
TC150240-5
-
120/240 TC25120D-5 TC50120D-5 TC75120D-5 TC100120D-5 TC150120D-5
Quantity as required
Print This Page | Close Window
Model
GR-FS4B2723TDB
Category
Metal Floor Racks
Product Description
27U, 23" Deep Rack w/Glass Door
Features:
Floor Standing Rack; 27U, 23" Deep; Steel Back Door; Vented Glass Front Door
•
•
•
•
•
•
•
•
•
•
•
•
Meets ANSI/EIA RS-310-D, DIN41491;Part1, IEC297-2, DIN41491;Part7, GB/T3047.2-92 standards
18 gauge removable side panels with spring latch
18 gauge SPCC cold rolled steel top and bottom
Perforated top
11 gauge front rack rails
10/32 rack screws
Rack U number printed on the rack rails
1/2", 5/8", 3/4", 1"1 and 1 1/2" cable entry knockouts on top and bottom
5/8" knockout design to be used for VHF/UHF antenna
Black powder coated finish
Adjustable depth front rack rails
Front door features toughened glass with vented sides and spring loaded push and turn locking system
Color:
Black
Hinges:
Hinged Doors
Latches: Lockable Doors
Wheels
Optional Casters
Interior Dimensions
Interior Width:
19.00''
Interior Height: 47.25''
Rack Dimensions
Rackable Depth (to rear lid): 22.25''
Rack Units:
27
Exterior Dimensions
Shipping Dimensions
Exterior Length: 57.40''
Exterior Length: 57.40''
Exterior Width:
23.60''
Exterior Width:
23.60''
Exterior Height:
23.60''
Exterior Height:
23.60''
Weight:
152.1
Weight:
152.1
REQUIRES 120VAC RECEPT IN CEILING SPACE.
REQUIRES 1 HOME RUN OF 2 TWISTED PAIRS
PERSONAL ALERT RECEIVER IN CEILING SPACE OF CHALLENGING NEEDS
HOME RUN 2 TWISTED PAIR TO INTERCOM SYSTEM HEADEND
RONCOLI SCHOOL - ST. JOHN'S
NOTE:
CLOCK WIRE IS 2 #12 WITH A
MAXIMUM OF 30 CLOCKS PER ZONE
DUAL FACED CLOCK COUNTS AS TWO
IC WIRE iS 2 TWISTED PAIRS MIN
24AWG
DOOR INTERCOM STATION MOUNTED IN 2-GANG BOX