Cello Brochure
Transcription
Cello Brochure
Cello Balloon Guide Catheter Ordering Information Product Number Product Name Conformable Sheath Tip Length (mm) Balloon Length (mm) ID (mm) Effective Length (cm) Total Length (cm) 1610080 Cello 8F 8F 3 10 1.90 (0.075 in) 95 102 Cello ™ Balloon Guide Catheter Cello Balloon Guide Catheter Device Details Balloon Length: 10 mm Injection Port for Main Lumen Catheter Tip Before Inflation Balloon Marker Aspiration Port for Balloon 10 mm Inflated Balloon Balloon Marker Solitaire FR Revascularization Device Information Reference Number Size (mm) Recommended Vessel Diameter (mm) Push Wire Length (cm) Minimum Microcatheter ID (in) Distal Markers Proximal Markers SRD-4-15 4 x 15 2.0 – 4.0 180 0.021 3 1 SRD-4-20 4 x 20 2.0 – 4.0 180 0.021 3 1 SRD-6-20 6 x 20 3.0 – 5.5 180 0.027 4 1 SRD-6-30 6 x 30 3.0 – 5.5 180 0.027 4 1 Maximize Clot Capture Reference: 1. Design Specification: PS08-001F. Indications, contraindications, warnings, and instructions for use can be found in the product labeling supplied with each device. The Cello Balloon Guide Catheter is intended to temporarily block blood flow by expanding a balloon inside blood vessels during operations, such as: urgent hemostasis, hemostasis for surgery, perfusion of blood to peripheral vessel, and arterial injection for chemotherapy. The Solitaire FR Revascularization Device is designed for use in the flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion. Patients who are ineligible for intravenous tissue plasminogen activator, IV t-PA, or who fail IV t-PA therapy are candidates for treatment. Cello is a trademark of Fuji Systems Inc. Solitaire and ForceFlex are trademarks of ev3. NEUROVASCULAR | PERIPHERAL VASCULAR Balloons · Embolic Coils · Embolic Protection · Flow Diversion · Flow Restoration · Guidewires · Liquid Embolics · Micro Catheters · Remodeling Devices · Retrieval Devices ev3 Europe International Headquarters 106-108 rue La Boétie 75008 Paris France PH +33 156 88 59 10 FX +33 156 88 59 11 www.ev3.net © 2011 ev3. All rights reserved. ev3 Corporate World Headquarters Peripheral Vascular 3033 Campus Drive Plymouth, MN 55441 USA PH +1 763 398 7000 FX +1 763 398 7001 Cust Srvc +1 800 716 6700 ev3 Neurovascular 9775 Toledo Way Irvine, CA 92618 USA PH +1 949 837 3700 FX +1 949 837 2044 ev3 International Distribution Centre Europalaan 25 6199 AB Maastricht-Airport The Netherlands PH +31 (0) 433 659 220 FX +31 (0) 43 364 6395 ev3 SAS France PH +33 (0) 156 88 31 10 FX +33 (0) 156 88 31 11 ev3 S.r.l Italy PH +39 0267 977 61 FX +39 0266 711 637 ev3 GmbH Germany, Austria PH +49 228 528 8310 FX +49 228 528 8360 ev3 B.V. Benelux PH +31 (0) 433 659 223 FX +31 (0) 433 650 283 ev3 Nordic AB PH +46 859 000 950 FX +46 859 000 959 ev3 Ltd. United Kingdom PH +44 1279 659 900 FX +44 1279 654 900 ev3 Technologies Iberica, S.L. Spain PH +34 91 656 7154 FX +34 91 656 7214 ev3 Sp z o.o. Poland PH +48 32 747 01 44 FX +48 32 747 01 45 0086 75990-001 (A) FEB/11 – Intl. www.ev3.net Cello™ Optimize device delivery Outer Braid • Overlapping braided tubes provide kink resistance and strong support for device delivery Balloon Guide Catheter • Two marker bands for device visibility and placement Inner Braid Improve proximal flow arrest and aspiration during clot retrieval Maximize aspiration Cello with Solitaire™ FR Revascularization Device ID: 1.90 mm OD: 2.55 mm • Large lumen catheter ensures high aspiration force Complete your ev3 stroke system • Designed to reduce ovalization, Cello contains braiding in both inner and outer layers intended to enhance structural integrity Radiopaque Markers • When paired with the Solitaire FR Revascularization Device, the Cello Balloon Guide Catheter can help prevent distal embolization during a revascularization procedure and improve patient outcomes Minimize vessel damage • The Cello balloon is designed to minimize vessel wall contact during flow occlusion H L • The Solitaire FR Revascularization Device with ForceFlex™, an overlapping stent design, provides technology to restore flow, retrieve clot, and revive neurological tissue 1 FORCEFLEX™
Similar documents
IV Centenari de Shakespeare Descarrega`t el catàleg
168 pàgines ISBN: 978-84-316-7889-0
More information