Cello Brochure

Transcription

Cello Brochure
Cello Balloon Guide Catheter Ordering Information
Product
Number
Product
Name
Conformable
Sheath
Tip Length
(mm)
Balloon Length
(mm)
ID
(mm)
Effective Length
(cm)
Total Length
(cm)
1610080
Cello 8F
8F
3
10
1.90 (0.075 in)
95
102
Cello
™
Balloon Guide Catheter
Cello Balloon Guide Catheter Device Details
Balloon Length: 10 mm
Injection Port for Main Lumen
Catheter Tip
Before Inflation
Balloon Marker
Aspiration Port for Balloon
10 mm
Inflated Balloon
Balloon Marker
Solitaire FR Revascularization Device Information
Reference
Number
Size
(mm)
Recommended
Vessel
Diameter (mm)
Push Wire
Length (cm)
Minimum
Microcatheter ID (in)
Distal
Markers
Proximal
Markers
SRD-4-15
4 x 15
2.0 – 4.0
180
0.021
3
1
SRD-4-20
4 x 20
2.0 – 4.0
180
0.021
3
1
SRD-6-20
6 x 20
3.0 – 5.5
180
0.027
4
1
SRD-6-30
6 x 30
3.0 – 5.5
180
0.027
4
1
Maximize
Clot Capture
Reference:
1. Design Specification: PS08-001F.
Indications, contraindications, warnings, and instructions for use can be found in the product labeling supplied with each device.
The Cello Balloon Guide Catheter is intended to temporarily block blood flow by expanding a balloon inside blood vessels during operations, such as: urgent hemostasis, hemostasis for surgery, perfusion
of blood to peripheral vessel, and arterial injection for chemotherapy.
The Solitaire FR Revascularization Device is designed for use in the flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion. Patients who are ineligible for intravenous
tissue plasminogen activator, IV t-PA, or who fail IV t-PA therapy are candidates for treatment.
Cello is a trademark of Fuji Systems Inc.
Solitaire and ForceFlex are trademarks of ev3.
NEUROVASCULAR | PERIPHERAL VASCULAR
Balloons · Embolic Coils · Embolic Protection · Flow Diversion · Flow Restoration · Guidewires · Liquid Embolics · Micro Catheters · Remodeling Devices · Retrieval Devices
ev3 Europe
International Headquarters
106-108 rue La Boétie
75008 Paris
France
PH +33 156 88 59 10
FX +33 156 88 59 11
www.ev3.net
© 2011 ev3. All rights reserved.
ev3 Corporate
World Headquarters
Peripheral Vascular
3033 Campus Drive
Plymouth, MN 55441
USA
PH +1 763 398 7000
FX +1 763 398 7001
Cust Srvc +1 800 716 6700
ev3 Neurovascular
9775 Toledo Way
Irvine, CA 92618 USA
PH +1 949 837 3700
FX +1 949 837 2044
ev3 International
Distribution Centre
Europalaan 25
6199 AB Maastricht-Airport
The Netherlands
PH +31 (0) 433 659 220
FX +31 (0) 43 364 6395
ev3 SAS France
PH +33 (0) 156 88 31 10
FX +33 (0) 156 88 31 11
ev3 S.r.l Italy
PH +39 0267 977 61
FX +39 0266 711 637
ev3 GmbH Germany, Austria
PH +49 228 528 8310
FX +49 228 528 8360
ev3 B.V. Benelux
PH +31 (0) 433 659 223
FX +31 (0) 433 650 283
ev3 Nordic AB
PH +46 859 000 950
FX +46 859 000 959
ev3 Ltd. United Kingdom
PH +44 1279 659 900
FX +44 1279 654 900
ev3 Technologies
Iberica, S.L. Spain
PH +34 91 656 7154
FX +34 91 656 7214
ev3 Sp z o.o. Poland
PH +48 32 747 01 44
FX +48 32 747 01 45
0086
75990-001 (A) FEB/11 – Intl.
www.ev3.net
Cello™
Optimize device delivery
Outer Braid
• Overlapping braided tubes provide kink resistance and strong
support for device delivery
Balloon Guide Catheter
• Two marker bands for device visibility and placement
Inner Braid
Improve proximal flow arrest and aspiration
during clot retrieval
Maximize aspiration
Cello with Solitaire™ FR Revascularization Device
ID: 1.90 mm
OD: 2.55 mm
• Large lumen catheter ensures high aspiration force
Complete your ev3 stroke system
• Designed to reduce ovalization, Cello contains braiding in both
inner and outer layers intended to enhance structural integrity
Radiopaque Markers
• When paired with the Solitaire FR Revascularization Device, the Cello
Balloon Guide Catheter can help prevent distal embolization during a
revascularization procedure and improve patient outcomes
Minimize vessel damage
• The Cello balloon is designed to minimize vessel wall
contact during flow occlusion
H
L
• The Solitaire FR Revascularization Device with ForceFlex™, an
overlapping stent design, provides technology to restore flow,
retrieve clot, and revive neurological tissue 1
FORCEFLEX™

Similar documents