Online UPS 1:1 phase
Transcription
Online UPS 1:1 phase
Online UPS 1:1 phase UM700 UM Series UM700-RM 0.7KVA - 700VA UM1000 UM1000-RM Voltage Range 700VA - 3000VA 1:1 Phase Small network, servers and other IT equipment. UM3000 UM3000-RM 3KVA / 3000VA 70 - 138 VAC 45 - 65 Hz Phase Single phase Power Factor 0.97 Voltage Range 110 / 115 / 120 VAC ± 2% Frequency Range 50Hz / 60Hz (auto-sensing) THD (linear load) <3% THD (non-linear load) <6% Overload Capability >100% 30S to bypass; >150% 300mS to bypass Crest Factor 3:1 (max) Short Circuit Protection 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode) 5 cycles turn off inverter, provide alarm (battery mode) input fuse blown or breaker action (bypass mode) Pure sine wave Between AC mode and battery mode: 0mS Transfer Time Between AC mode and Bypass mode: 4mS (typical value 2.5mS) >83% Efficency >85% 12V sealed lead acid maintenance free Model 36VDC DC Voltage 1. High frequency and double conversion online technology 2. Fully digitized microprocessor control 3. Wide input voltage range 4. LCD display 5. UPS start up without battery 6. Cold start 7. Advanced battery management 8. Automatic battery charging in UPS off mode 9. Lightning and surge protection 10. Short circuit and overload protection 11. Fan speed auto control when loads varies 12. Network/fax/modem surge protection 13. Optional extension battery pack 14. Battery voltage display 15. Load capacity display 16. EMI/RFI noise filter 17. Smart RS232 communication with monitoring software 18. Optional SNMP card slot 19. EPO function (optional) 20. Input L and N reversed alarm function UM2000-RM 2KVA / 2000VA Frequency Range Waveform 1. LCD 2. ON/OFF Button 3. Self-test/Silence Button 4. Scroll Button 5. Normal 6. Alarm 7. Abnormal UM2000 1KVA / 1000VA 96VDC Battery 3x12V/9AH 3x12V/7AH 8x12V/7AH 8x12V/7AH Backup Time (half load) 22min 12min 19min 16min Backup Time (full load) 10min 5min 8min 5min Charge Current (standard unit) 1A (minimum) 1A (minimum) 1A (minimum) 1A (minimum) Charge Current (long time unit) 7A 7A 7A 7A Recharge Time 80% capacity after 4 hrs charging RS232 ; SNMP (optional) 1. Input voltage/frequency, battery voltage, output voltage/frequency, load watt/VA and percent, inverter temperature. 2. Operation mode such as “on line”, “on batt” or “on bypass”. 1. Green LED for normal operation. 2. Yellow LED for warning condition. 3. Red LED for abnormal operation. <45dB Rear Panel SNMP slot Rs232 Battery socket Fan Rj45 www.upsonic.net Tower From 0 to 40 ºC Humidity 0% - 95% (non-condensing) <1500m Altitude -25 to Storge Temperature Output socket Rack mounted Temperature Input socket Input breaker 55 ºC Standard Unit Net/Gross Weight 14.7/16.7Kg 14.7/16.7Kg 14/16Kg 14/16Kg 33/35Kg 34/36Kg 34/36Kg 35/37Kg Long Time Unit Net/Gross Weight 8.2/9.7Kg 8.2/10.7Kg 7.5/9Kg 8/10Kg 14/16Kg 19/21Kg 15/17Kg 20/22Kg Dimension (WxDxH)mm 144x419x215 483x400x89 144x419x215 483x400x89 191x478x339 483x520x89 191x478x339 483x520x89 Packing (WxDxH)mm 258x524x334 587x550x254 258x524x334 587x550x254 332x603x482 592x665x292 332x603x482 592x665x292 1. Tower and rack mount. 2. Advanced battery managment technology, comprehensive protection, local and remote monitoring. 3. Provide high security to the load. Wide input voltage range 70 ~ 138VAC, without discharge batteries. 4. High MTBF (Mean Time Between Failure) >100.000 hours.
Similar documents
Silencio® range
UM650 UM650++UM601 UM601 UM650 UM650++UM601 UM601 UM700 UM700++UM655 UM655 UM700 UM700++UM602 UM602 UM650 UM650++UM601 UM601 UM602 UM602++UM602 UM602 UM700 UM700++UM602 UM602 UM700 UM700++UM655 UM655
More information