Chili User Manual-15
Transcription
Chili User Manual-15
Mooresville,NorthCarolina USER MANUAL SingleZone DualZone UsethisguidetodescribeuseandsetupaswellasoffertroubleshootingtipswithyourChili Product. Iftheissuestilloccurs,pleasecontact [email protected]‐877‐235‐6271. Note:Pleasereadtheseinstructionscarefullybeforeuse. pg. 2 Table of Contents Introduction. Page5 Beforeyougetstarted. Page6 Safetyinstructions. Page7‐8 Contents. Page9 UsingtheCube. Page10 Set‐upinstructions. Page11‐15 Maintenance. Page16‐17 Storage. Page18 TechnicalParameters. Page19 Troubleshooting. Page20 pg. 3 Chili Technology™ welcomes you to a new sleep experience! Wearededicatedtoadvancesinsleepengineering.Ourgoalistogive youaperfectnight’ssleepbyenablingyoutopersonalizeyoursleep environment. AsyousetupyourChiliPad™Cube,wehopeyouenjoyyourexperience andfindyourownsleeptemperatureandindividualdegreeof comfort. 3 pg. 4 INTRODUCTION TheChiliTechnology™Cubeisa revolutionarycoolingandwarming systemthatregulatesthesurface temperatureofyourmattressfora perfectnight’ssleep.Chili Technology™canbeused12months outoftheyearandisdesignedto improveyoursleep,nightafternight. Thesiliconecirculationtubesrun conditionedwaterthroughoutthe mattresssurfacetomaintainyour idealsleeptemperature. ThecontrolunitforyourChiliPad™is referredtointhismanualastheCube. TheChiliTechnology™coolingandwarmingsystemallowsadjustments tobemadetoyourbeddingsurface.TheCubecoolsorwarmswaterto yoursettemperatureandcirculatesitthroughthepad,generally achievingtemperatureswellbelowacool55ºF(13ºC)andeasilyabove averywarm110ºF(43ºC).TheCubemotor45dBandonlyuses170 Wattsofpower.UsetheChiliPad™Cubetosetthetemperatureofyour bedinsteadofheatingorcoolingyourentirehousewhileyousleep. Keepingyourhomethermostatatamoremoderatetemperature translatesintorealenergysavingsthatallowyourChili™producttopay foritself! pg. 5 BEFORE YOU GET STARTED 1.KeeptheCubeawayfromareasthatmightbecomedamporwet,such asanopenwindow.TheCubeshouldbeplacedonadry,firmfloor,ina well‐ventilatedarea,freefromsurroundingfabric.Spacingofatleast24 inches(60cm)shouldbeleftonallsidesandtopoftheunit.Never operatetheCubeunderabed. 2.Neverturnthecubeonbeforetheconnectionhosecomingfromthe padhasbeenconnectedtotheCube. 3.TheCubemusthavewateraddedbeforeinitialuse.Youwillneedto addadditionalwateroninitialset‐upasthemattressfillswithwater. Refertothe“Set‐Up”sectionofthismanualforfullinstructions. 4.AvoidanybendsorkinksofthehosebetweentheCubeandthe ChiliPad™ 5.BecarefulwithsharpobjectsneartheChiliPad™toavoidpuncturesof thecirculationtubing. 6.Children,someindividualswithdisabilitiesorindividualswith cognitiveimpairmentsmustbeunderadultsupervisionwhenusingthe ChiliPad™Cube. 7.TheCubeistobeusedonastandardACpowercircuitoftheproper voltage. 8.TurnOFForunplugwhennotinuse. 9.TheCubeisprogrammedtoturnoffautomaticallyafter10hoursof continualuse.TheCubecanbeturnedonagainmanuallyafterit automaticallyturnsitselfoff. 10.OverheatingmayresultfromusingtheCubeinanymannerother thanasdescribedinthismanual. 11.WrappingthepowercordaroundtheCubemaydamagethecord. Pleasewrapthepowercordlooselyduringstorage. 12.IftheCubeisnotworkingproperly,unplug,discontinueuseand immediatelycontactChiliTechnology™CustomerServiceat [email protected]‐235‐6271. pg. 6 Save these instructions SketchA. GROUNDINGINSTRUCTIONS Thisproductmustbegrounded.Ifitshouldmalfunctionorbreakdown,groundingprovides apathofleastresistanceforelectriccurrenttoreducetheriskofelectricshock.This productisequippedwithacordhavinganequipment‐groundingconductoranda groundingplug.Theplugmustbepluggedintoanappropriateoutletthatisproperly installedandgroundedinaccordancewithalllocalcodesandordinances. DANGER!Improperconnectionoftheequipment‐groundingconductorcanresult inariskofelectricshock.Checkwithaqualifiedelectricianorservicemanifyou areindoubtastowhethertheproductisproperlygrounded.Donotmodifytheplug providedwiththeproduct–ifitwillnotfittheoutlet,haveaproperoutletinstalledbya qualifiedelectrician.Thisproducthasagroundingplugthatlooksliketheplugillustratedin sketchA.Makesurethattheproductisconnectedtoanoutlethavingthesame configurationastheplug.Noadaptershouldbeusedwiththeproduct. pg. 7 IMPORTANT SAFETY INSTRUCTIONS Useofelectricalappliancesrequiresthefollowingprecautionstoreducetheriskof fire,electricshock,andinjury. 1) Readallinstructionsbeforeusingthiscoolingandwarmingbedsystem. 2) WARNING–Donotusethiscoolingandwarmingbedsystemwithinfants,individualswith diminishedcapacityoranyoneinsensitivetoheatsuchasapersonwithpoorbloodcirculationunless undersupervision. 3) WARNING–Donotusethiscoolingandwarmingbedsystemwithanyotherheatedblanket, comforter,quilt,sheet,mattresspad,mattress,footwarmer,throwblanket,orsimilarcoolingorheating bedding. 4) WARNING–Topreventapossiblefire,donotblockairintakesorexhaustinanymanner.Donot usetheelectricaldeviceonsoftsurfaces,likeabed,whereopeningsmaybecomeblocked.Donot operateunderthebed. 5) Useclosesupervisionwhenthiscoolingandwarmingbedsystemisbeingusedbyandaroundchildren orindividualswithcognitiveimpairments. 6) Donotimmersethecoolingandheatingdeviseinwater. 7) Donotplacepowercordbetweenmattressandfoundation.Donotrunundercarpeting.Donotcover cordwiththrowrugs,runners,orsimilarcoverings.Donotroutepowercordunderfurnitureor appliances.Arrangepowercordawayfromtrafficareasandwhereitcouldbetrippedover.Donotallow thecordstobepinched. 8) Donotoperatethisproductintheeventthatthepowercordorplugbecomesdamaged. 9) Keeppowercordawayfromheatedsurface. 10) Alwaysplugthisproductdirectlyintothewalloutlet/receptacle.Neverusewithanextensioncordora power/outletstripthatcanberelocated. 11) Intheeventthatthecoolingandheatingsystemmalfunctions,isnotoperatingorifdroppedinwater or damagedinanymanner,pleasecontactChiliTechnology™. 12) Turnofforunplugwhennotinuse. 13) Donotuseoutdoors. 14) Tounplugthiscoolingandheatingsystem,turncontrolstooff,thenremovepowerplugfromoutlet. 15) Donotinsertorallowforeignobjectstoenteranyventilationorexhaustopeningasthismaycausean electricshockorfire,ordamagethecoolingandwarmingdevice. 16) Neveroperatethecoolingandwarmingdevicewiththeairopeningsblocked.Keeptheairopeningfree fromanydebris. 17) Acoolingandwarmingsystemhashotandarcingorsparkingpartsinside.Donotuseitinareaswhere gasoline,paint,orflammableliquidsareusedorstored. 18) Donotuseattachmentsnotrecommendedbythemanufacturer. 19) Donotoperatewhereaerosol(spray)productsarebeingusedorwhereoxygenisbeingadministered. 20) Donotopenorbreakthehousingonthiscoolingandwarmingdeviceasthiswillinvalidateyour warranty. 21) WARNING:RiskofElectricShock– Connectthis furnishingtoaproperlygrounded outletonly.SeeGroundingInstructions. 22) Usethisproductonlyforitsintendeduseasdescribedintheseinstructionswithinthismanual.Any otherusenotrecommendedbythemanufacturermaycausefire,electricshock,orinjurytopersons. pg. 8 CONTENTS The Cube OneCubeperZone. The Pad Padwillfitsnugglyoveryour mattress&supportivestraps willkeepthepadinplace. The Remote OneRemoteperZone. pg. 9 USING THE CUBE pg. 10 SET‐UP INSTRUCTIONS Mattress,WaterproofMattressProtector,ChiliPad™,FittedSheet, ThenComforter. CompletelyunfoldtheChiliPad™andplaceitflatontopofyour waterproofmattressprotectorwhichisontopofyourmattress(seeset uporderabove).Thetailpipe(tubethatconnectsthepadtotheCube), canbeattheheadorthefootofthebed. PositiontheelasticstrapunderneaththemattresstokeeptheChiliPad™ inplace. PlaceyourfittedsheetdirectlyovertheChiliPad™. Foroptimalperformance,adenseblanketorcomfortershouldbeplaced overthebodywhentheChiliPad™Cubeisinusetoprovidetheneeded insulationtokeepthebeddingsurfacecoolorwarm. ConnectingChiliPad™tubingtotheCube. PlaceyourChiliTechnology™Cubeonahardflatsurfacenearyourbed. Rememberthatspacingofatleast24inches(60cm)shouldbeleftonall sidesandabovetheunit(thisiscriticaltooptimalperformanceofthe system). ConnectthetubingfromyourChiliPad™producttotheCubeasshown below.Youmustheara“click”soundtoensureproperconnection. Note:Ifyouneedtodisconnectthetubing, pressthetubedisconnectbuttonlocatedon thebottomoftheCube.Pleasenotethatafew dropsofwatermayresultwhendisconnecting thetubing. pg. 11 SET‐UP CONTINUED ConnectingthePower. Plugthepowercordintoanoutlet. Note:Thisdevicehasagroundedplug.Toreducetheriskofelectricshock,thisplugis intendedtofitinagroundedoutletonlyoneway.Ifitdoesnotfit,contactaqualified electrician.Donotmodifythepluginanyway. FillingtheCubewithWater.Distilledwaterisrecommended Youwillneedtofillthewaterreservoirbeforethefirstuse. ThewaterreservoirislocatedonthetopcenteroftheCube. Unscrewandremovethecap,thenaddwateruntilthereservoirisfull(approximately 14oz/390ml).Note:HaveadditionalwaterreadytopourafterCubeisstartedtofillthe tubinginthePad. TurntheCubeonbytouchingtheON/OFFbutton. TheCubewillbeepandthepumpwillbegintorun(Thisiswhereadditionalwaterwill beneededasthewaterinthereservoirwillbepumpedintothePad). AswaterstartscirculatingthroughthetubinginyourChiliproduct.Continueto slowlyfillthereservoiruntilthewaterlevelreachesthebottomofthecapthreadlines (thisamountwillvarydependingonthesizeofyourpad). o Usecleanwater.Distilledwaterisrecommended. o DonotimmersetheCubeinwatertofill. o BecarefulnottospillwaterontheCube. o RefillthewaterreservoirwhenthewaterlevelgetslowortheLowWaterlight comeson.TheCubewillnotoperatewhenthewaterlevelinthereservoiris tooloworempty. TurningtheCubeOn. PresstheON/OFFbuttonontheCubeorremote.TheCubewillbeepandthepumpwillbegin torun. pg. 12 SET‐UP CONTINUED ToCool: PresstheCOOLERbuttontoselectyourdesiredtemperature. Thedigitalreadingonthedisplaywillblink3timestoindicatethesettingwasaccepted. TheCubewillstarttoworkanddisplaytheactualtemperature. ToWarm: PresstheWARMERbuttontoselectyourdesiredtemperature. Thedigitalreadingonthedisplaywillblink3timestoindicatethesettingwasaccepted. TheCubewillstarttoworkanddisplaytheactualtemperature. Note:Thetemperatureadjustmentstepscanbecompletedwiththeremotecontroloron theCubedisplaypanel. UsingtheRemote. RemotePairing: PlugintheCube. Touchthe“ON/OFF”buttonontheCubedisplaypanelandholdfor5seconds.The Cubewillsoundalongbeepandthedisplaywillshowablinking“888”. TurntheremotecontrolON.TheCubewillsoundashort“beep”anddisplaythe actualtemperature. SwitchingBetweenºFandºC: TurnOFFtheremotecontrol. TurnONtheCubeonthedisplaypanel. Pressthe“ON/OFF”buttontheremotecontrolandholdfor2seconds. pg. 13 SET‐UP CONTINUED TurningtheCubeOff. PresstheON/OFFbuttonontheCubeorremote.TheCubewillbeep,thenthepump andfanwillstoprunning.Thepumpand/orfanmaycontinuetorunforashorttime oncetheunithasbeenturnedoff.Iftheunitisnottobeusedfora24‐hourperiod, unplugfromthewall. AdjustingtheTemperature. TheCubemustbeturnedontoadjustthetemperature.TheCubecoolsorwarms waterinindividualdegreeincrementsbetween55ºF(13ºC)and110ºF(43ºC).The Cubewillcoolbelow55ºF(13ºC)onthecool“LO”settingandabove110ºF(43ºC) onthecozy“HI”setting.Oncedesiredtemperatureisset,watercirculatesthrough thepadgenerallyachievingyourdesiredtemperature. Insomecasesthemaximumandminimumtemperatureswillnotbereacheddueto someofthefollowingfactors:ambientairtemperature,humidity,individualbody heat,insulation,allowingtheunitsufficientairflowandheatloadontopoftheChili product.Formaximumperformance,itisrecommendedthateachindividualhavehis orherownCube. MaximumTemperatureChange. Condensationmayoccuronthetubingand/orpadbasedonambientair temperature,humidity,andindividualbodyheat.Toaddressthis–adjusttheair temperatureoftheroomlowerand/ortheCubetemperaturehigher.Pleaseseethe troubleshootingguideforinformationonhowtosolvethisissueorrefertotheChili GuruVideosonourwebsite(www.chilitechnology.com)fortroubleshootingor furtherassistance. OperationalTips. InsurethereisamplespacearoundtheCubeforventilation.TheCubeusesfreshair tocooltheelectronics,sosufficientfreshairisnecessaryforoptimalperformance andlonglifeofyoursystem. Clearanceof24inches(60cm)onallsidesandaboveisrecommendedforoptimal performanceandlongevity.TheCubecanneverbeoperatedunderthebed. Frequentlyinspecttheconnectiontubestoinsuretherearenokinksorrestrictions thatmaypreventfreeflowofthewaterthroughyoursystem. Usethefollowinglinktoaccesscleaningtips: http://www.chilitechnology.com/chili‐guru‐help‐videos/ pg. 14 SET‐UP CONTINUED FCCCompliance. Theremotedevicecomplieswithpart15oftheFCCrules.Operationissubjectto thefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference, and(2)thisdevicemustnotacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation. Warning:Changesormodificationstothisunitwillvoidthemanufactures warranty. Note:Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfora ClassBdigitaldevice,pursuanttopart15oftheFCCrules.Theselimitsare designedtoprovidereasonableprotectionagainstharmfulinterferenceina residentialinstallation.Thisequipmentgenerates,usesandcanradiateradio frequencyenergy.Ifnotinstalledandusedinaccordancewiththeseinstructions, itmaycauseharmfulinterferencetoradiocommunicationsandthereisno guaranteethatinterferencewillnotoccurinaparticularsituation.Ifthis equipmentdoescauseinterferencewithTVorradioreception,whichcanbe determinedbyturningthedeviceonandoff,theuserisencouragedtotryto correcttheinterferencebyoneormoreofthefollowingmeasures. Reorientorrelocatethereceivingantenna. Increasetheseparationbetweenthetwodevices. Plugthetwodevicesintodifferentwalloutlets. ConsultChiliTechnologyCustomerServiceforassistance. pg. 15 MAINTENANCE Onceamonthmaintenance WaterMaintenance Distilledwaterisrecommended. Onetimepermonthadd¼cup(2oz/59ml)ofhydrogen peroxideintothewaterreservoirtokeepthecirculation systemclean.Procedure:Settemperatureto90ºF(32ºC). Removethewaterreservoircapandaddthehydrogen peroxide.LEAVETHEWATERRESERVOIRCAPOFF.The hydrogenperoxidewillreactwithanydirtorotherforeign particlestocleanthesystem.Oncethereactionhasstopped (bubblesnolongerform)or20minuteshaspassed,replace thecap,resettheCubetoyourdesiredsleeptemperature andenjoy. CleaningtheCube WiththeCubeturnedoffandunplugged,useacleandamp clothtocleantheoutsideoftheCubeandremotecontrol. Useonlymildsoapifnecessary.Becarefulnottogetwater insideoftheCube. Usecanofcompressedair(orsimilar)toblowthroughthe intake/exhaustventsonallsidesremovingdustanddebris. NeversubmergeorgetwaterinsidetheCube. WashingthePadasneeded ThePadiswashableinafrontloadingwashingmachine– COLDWATERONLY. Securethetailpipe(partthatrunsfromthepadtothe Cube)withathickrubberbandorothermeanstominimize riskofitflailinginthespincycleanddamagingthe connector. UseonlyGENTLE/DELICATEwashingcycleandfeelfreeto addalittleOxyClean™orsimilarcleanerthatincludes peroxideintheactiveingredients. DryonDELICATE/AIRONLYcycle–UseNOHEATsetting orairdry. pg. 16 MAINTENANCE ‐ CONTINUED Everythreemonths DeepCleaning Emptyallwaterfromcontrolunit(s) Fillunit(s)with½cup(4oz/118ml)ofhydrogen peroxide Completelyfillunit(s)withdistilledwater Rununit(s)on“HI”settingwithCAPOFFfor6‐8hours. Placeunit(s)higherthanpadtoensurewaterdoesnotspill outofthetopoftheunit(s) Afterheatingcycledumpwater/hydrogemperoxide mixtureandrefillwithdistilledwater. o Ifcleaninghasnotbeenperformedbefore,orhas beenlongerthan3months,repeatingthisprocess mayfurtherimproveperformance. Oncethiscleaningprocessiscomplete,runsystemas normal,includingthenormalhydrogemperoxideadditive. pg. 17 STORAGE DisconnecttheTubing IfyouneedtodisconnectthetubingfromtheCube: Pressthetubedisconnectbuttonlocatedonthebottomofthe Cube(refertopage9). Removethetubefromtheconnector. Note:Removingthetubewithoutpressingthetubedisconnect buttonlocatedonthebottomoftheunitcandamagethe connectors. HowtoremovewaterfromtheChiliPad™ IftheCubewillnotbeinuseforanextendedperiod,youshouldpurgethe waterfromboththeCubeandthePad. TodraintheChiliPad™youwouldusewaterdrainage adapter.Toobtainoneofthesepleasecontact [email protected]‐877‐235‐ 6271. TodrainthewaterfromtheCube(afterunpluggingand disconnectingthepad),takethecubetoasinkorbucket, removethewaterreservoircapanddrainthewater(pour awayfromthedisplaypanel,i.e.drainfromoppositesideofthe connectorsinordertoavoidgettinganywateronthedisplay panel). StoringtheCube DisconnecttheconnectiontubingfromtheCubeusingthe disconnectbuttononthebottomontheCube(refertopage 12). Drainanyremainingwaterfromtheunitbyremovingthe waterreservoircap.GentlytilttheCubesothewaterdrains throughthereservoiropening.Replacethecap. WrappingthepowercordaroundtheCubemaydamagethe cord.Pleasewrapthepowercordlooselyduringstorage. Removethebatteriesfromtheremotecontrol. StoretheCubeandremotecontrolinaclean,dryplace. PleasevisitourChiliGuru’sforadditionalassistancewithroutinecleaningand maintenance.http://www.chilitechnology.com/chili‐guru‐help‐videos/ pg. 18 TECHNICAL PARAMETERS RatedVoltage AC90~230V RatedFrequency 50Hz–60Hz TemperatureControl Lowerthan55ºF(13ºC)and Higherthan110ºF(43ºC) RatedPower 170W Power 170W RatedAmperage 2.2–2.3A UsethisguidetoaddressproblemswithyourChiliProduct.Iftheissue stilloccurs,pleasecontactcustomerserviceat [email protected]‐877‐235‐6271. pg. 19 TROUBLESHOOTING Don’tforgettovisitourChiliGuruhelpsectionformorehelpfultipsandtricks! Visitwww.chilitechnology.comandclicktheFAQtab. Issue PossibleReason Solution Checktoseeiftheoutlethas power.Iftheelectricalcordis NoPower damaged,unplugand immediatelycallcustomer service. Besurepowercordissecurely Disconnectedfrompower Doesnotturnon insertedintoCubepower source socket. Poor cooling/warming effect Reservoirisoutofwater AddwaterbyfollowingtheSet‐ UpInstructionsinthismanual. Remoteisnotworking Replacethebatteries. Reservoirislowonwater AddwaterbyfollowingtheSet‐ Upinstructionsinthismanual. Tubingiskinked Nocoveringoveryour bodywhenyousleep. Condensation 20ºF(10ºC)differencein airtemperatureandthe Cubetemperaturesetting Unitisequippedwith severalautomaticshut‐off functionstoprotectthe Errorcodedisplayed system;anerrorcode onCubedisplaypanel indicatedthissituation hasoccurred(F1,F2,F3, F4,F5). MakesuretheChiliProductis flatonthebedandthereareno kinksinthetubing. Useacoveringlikeablanketor comforteroveryourbodyto helpinsulateyoursleeping environment. AdjusttheCubesettingup2º‐ 5ºF(1º‐3ºC)untilthereisno longeracondensationbuildup. Turnoffandunplugunit.Wait 15minutes,turnuniton,and resetpreferredsleep temperaturesetting.Ifissue persists,noteerrorcode, unplugCubeandcontact customerservice. pg. 20