Trystar Brochure - Critical Facilities Summit
Transcription
Trystar Brochure - Critical Facilities Summit
Generator DOCKING STATIONS CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Portable Power Cable Cam to cam cable extensions DESCRIPTION • 2000V, 100A-400A rated to NEC table 400.5 (B) • All portable power cable sold is highly flexible and UL & C-UL or CSA Listed • MSHA Listed • Dual layer jacket with inner safety liner of contrasting color • Available in any color, including 208V & 480V phases • Your custom print on every foot of the cable Trystar® generator DOCKING STATIONS Trystar® Generator Docking Stations provide reliable, affordable • Up to 4000A assurance that your business stays up and running in any power outage. • Theft and Tamper Resistant Custom-mounted to your structure, each station allows for quick and easy connection of external generator power. And our unique design helps prevent theft and hazardous disconnects. • All cables are factory tested • Cam Lok READY • Custom Cabling and Powder Coating • Breaker Panels and More Striped Cable Distribution equipment Cable with integrity 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 3 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Portable Power Cable Pig tails, male or female, any length TRYSTAR® Commercial Grade Generator Docking Station DESCRIPTION DESCRIPTION • 2000V, 100A-400A rated to NEC table 400.5 (B) • Your custom print on every foot of the cable • Available for 100A to 400A service • All portable power cable sold is highly flexible and UL & C-UL or CSA Listed • All cables are factory tested • Powder coated aluminum or stainless steel construction GDS-044W-SM (pictured) • Lockable rake system reduces cable theft • MSHA Listed • Non-angled vertical Cam style inputs • Dual layer jacket with inner safety liner of contrasting color • UL and C-UL 50 listed enclosure, NEMA 3R • Available in any color, including 208V & 480V phases • Options are not available with this unit • Cam style to bare end with pin lugs or compression lugs available • Provides safe and easy cam connections to existing transfer switches • For use in residential and light duty environments Compression lug Pin lug Bare end 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com Docking station 400A 4 Pad lockable Phase colored cable 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 5 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Generator Docking Station TRYSTAR® Generator Docking Station with Locking Block Up to 4000A Up to 4000A Part #GDS-205W-LM (pictured) Part #GDS-405W-LM-K2 (pictured lower left) Part #GDS-045W-SM-K1 (pictured center and lower right) DESCRIPTION DESCRIPTION • Available for 100A to 4000A service • Available for 100A to 4000A service • Powder coated aluminum or stainless steel construction • Patented locking block incorporated into a standard Trystar GDS • Docking stations accommodate any style inlet or receptacle • Both doors will close only if the cable is not connected to the GDS • Kirk Key can be installed into a facility’s new or existing main breaker • Lockable rake system reduces cable theft & cable disconnection • Cam style inputs and/or outputs or other • The facility’s main breaker is used to lock out and transfer power from utility to generator • Only the provided key will open Trystar’s GDS with locking block • UL and C-UL 50 listed enclosure, NEMA 3R • UL and C-UL 50 listed enclosure, NEMA 3R • The key is captive and is only released by disconnecting the main breaker • Provides safe and easy cam connections to transfer switches Optional leg kit • Key releases only when doors of GDS are closed and locked 1200A output panel 400A docking station 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 4000A Closed 6 2917 Industrial Drive Faribault, Minnesota 55021 400A Closed 400A Open with rake system 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 7 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Rotary Generator Docking Station Up to 1200A CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Posi-Lok Generator Docking Station Part #GDR-125W-LM (pictured) DESCRIPTION DESCRIPTION • Integrated rotary transfer switch (ON - OFF - ON) • Powder coated aluminum or stainless steel construction • Available for 100A to 1200A service • Mounts to switches, buildings and generators • Powder coated aluminum or stainless steel construction • Posi-Lok® is designed for sequential, fool-proof hook up • Available with non-service entrance or service entrance rating • Lockable rake system reduces cable theft & cable disconnection • Lockable rake system reduces cable theft & cable disconnection Part #GDS-POSI • UL and C-UL 50 listed enclosure, NEMA 3R • Cam style inputs and/or outputs • Inside mount handle for added security • UL and C-UL 50 listed enclosure, NEMA 3R Portable option Utility - Off - Generator switch Pad lockable 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com Lockable 8 Posi-Lok cable Posi-Loks connected 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 9 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Hard-Wire Docking Station TRYSTAR® rental transfer switches with built in docking stations Generator Roll-Up Box Part #GDS-326P-LL (pictured) DESCRIPTION DESCRIPTION • Includes mechanical lugs suitable for up to 500MCM THHN cable • Optional stainless steel or powder coated aluminum • Double throw, manual (non-automatic) or automatic • Trap door access for easy hard wire connection • Docking Station integral to the switch • Secondary door offers additional protection between generator and electrical load • Heavy duty reinforced frame with 2 door support & access • UL and C-UL 50 listed enclosure, NEMA 3R • Add gland plates for any inlet or receptacle • Non service and service entrance rated • UL and C-UL 50 Listed enclosure Secondary door closed Hard wire connection Integral docking station Phase colored cable 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 10 Two full door access Fully wired 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 11 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. Trystar® Single or dual Breaker Docking Stations Trystar® Dual Kirk Key Breaker Docking Stations Part #SBDS (pictured) DESCRIPTION Part #DBDS (pictured) DESCRIPTION • Single breaker docking station with Kirk Key provision • Kirk-Key adaptable • Kirk key is provided for main breaker on building • Phase rotation monitor included • The key is captive in the building’s main breaker until it is shut off • Cam style connection or hard wire option available for input • The key is captive in the GDS breaker until it is shut off • UL and C-UL 50 listed enclosure, NEMA 3R • Phase rotation monitor included • Breaker A is for loadbanking a permanent generator • Full CAD drawings available upon request • When the main breaker is off, use the same key to turn on the GDS breaker • Up to 4000A per breaker • Standby power breaker cannot be energized unless the utility breaker is locked in the off position • Full CAD drawings available upon request • Breaker B is for a temporary generator • Cam style connection or hard wire option available for input • Ability to have a temporary generator connected during a load bank test •U L and C-UL 50 listed enclosure, NEMA 3R • Allows for quick, easy hook up of a portable generator if permanent generator goes down • Up to 4000A Closed view Open view 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com Closed view 12 Open view 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 13 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® DUAL PURPOSE GENERATOR/LOAD BANK DOCKING STATION PRODUCT NAME Part #DPGLBDS DESCRIPTION TRYSTAR® UTILITY BREAKERED OUTPUT PANEL Part #UOP DESCRIPTION • Cam style or hard-wire inputs and/or outputs • Available for 100A to 4000A service • Cam style or hard-wire outputs, or other • Phase rotation monitor included • Powder coated aluminum or stainless steel construction • Kirk key access to lock out permanent generator, giving access for roll up rental generator • Up to 4000A • Output panels accommodate any style outlet • Lockable rake system reduces cable theft and cable disconnection • Does not include any breakers • UL 50 and C(UL) 50 Listed enclosure, NEMA 3R • Breakers included to match specification • Quick and easier access to permanent generator for load banking Closed view 2917 Industrial Drive Faribault, Minnesota 55021 Open view 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com •U L 50 and C(UL) 50 Listed enclosure, NEMA 3R Closed view 14 2917 Industrial Drive Faribault, Minnesota 55021 Open view 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 15 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Docking station for Mobile Generators CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Generator Docking Stations mounted to ats Part #GDS-MG DESCRIPTION • Single or dual Kirk Key systems • Inserts into a mobile generator which provides flexibility for long or short-term projects • Breaker A is generator’s main, breaker B is the building’s main • Phase rotation monitor included • Up to 4000A per breaker • Full CAD drawings available upon request • Cam style connection or hard wire option available for input • UL and C-UL 50 listed enclosure, NEMA 3R Inside wiring of an ATS Closed view Back view Docking station 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 16 Inside wiring of an ATS 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 17 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. TRYSTAR® Inlet Generator Connection Panel TRYSTAR® Power 100A to 400A Trystar Steel Storage Vault DESCRIPTION DESCRIPTION • Powder coated aluminum or stainless steel construction • Lockable • Converts a panel from a mechanical lug connection to a quick connect panel • Capable of holding up to 3000 lbs. • Mounts to switches, buildings and/or generators • Nearly impenetrable • Complete with 30” tails sized to your requirement • Custom colors available Part #TSSV • Option for lockable front cover • UL and C-UL 50 listed enclosure, NEMA 3R Mounted to transfer switch Three phase 208V with pigtails Shown with lockable cover 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com Plastic collapsible bins 18 Plastic non collapsible bins 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 19 CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. CALL 1-866-TRYSTAR (879-7827) TO PLACE YOUR ORDER. Available in: Custom COLOR, Any Length, CUT, COILED, COMPLETE With CONNECTOR ASSEMBLY TRYSTAR® PORTABLE POWER CABLE (UL) C(UL) FEATURES CONSTRUCTION • Available colors: Black, blue, red, green, white, yellow, orange, brown or custom Conductor Make selections from the listed options. GDS • Bare, annealed electrolytic copper • 30 AWG Class K rope lay stranding • - 45°C to 105°C, 2000 Volt Rating, flame retardant • Resistant to oil, water, acid, gas, ozone, cuts, tears and abrasion GDS • (UL) 2000 volt rating, C(UL) 600 volts continuous use DUAL INSULATED JACKETING TECHNOLOGY • Manufactured to UL & C(UL) standard 1650, & MSHA Inner Jacket- Added for Your Safety A separator of high contrast color is applied between the conductor and outer sheath for your added safety. This provides: Increased insulation, added flexibility, and allows you to easily identify damage or wear. • Surpasses NEC 400 requirements and may be used in any application where PPE, Type W, G or G-GC cable is used. APPLICATIONS Designed for use with industrial equipment, including portable generators, chillers, air conditioning, motor and welding leads, submersible wells, grounding, heavy tools, power extensions, marine dockside, mining and oil drilling applications, where long term, quality performance at all operating temperatures is desired. TRYSTAR® GENERATOR DOCKING STATION SPECIFICATION Amperage Voltage Mount Style 32 5 P - Permanent Bus Connection Generator Connection (- (Optional Loadbank Connection) (Other Options List all after dash) ) L M (- LF A ) - example shown: GDS-325P-LM(-LFA) Amperage Outer Jacket TYPE PPE (FT5) Provides: oil, water, acid, gas, ozone, resistance, flame retardant, durability and extreme flexibility at all operating temperatures. Voltage Mount Style Permanent Bus Connection L - Mechanical Lugs (std) 02 - 200A 1 - 120/240 (2H + N + G) W - Wall hanging 04 - 400A 3 - 208/120V (3H + N + G) P - Pad (free standing) 08 - 800A 4 - 480V (3H + G) F - Flush (front flange) 12 - 1200A 5 - 480/277 (3H + N + G) 800A — 3 x 500 MCM 16 - 1600A 6 - 600V (3H + N + G) 1200A — 4 x 500 MCM Qty and size per phase 200 - 400A — 2 x 600 MCM 20 - 2000A 1600A — 6 x 500 MCM Indented into outer jacket: (UL) TYPE PPE 2000V 90°C 24 - 2400A 2000A — 8 x 500 MCM 75°C WET E204219 P-07-KA070022 C(UL) PPC/TPE FT-5 600V 90°C OIL RESISTANT 28 - 2800A 2400A — 10 x 500 MCM 32 - 3200A 40 - 4000A AVAILABLE SIZES, SPECIFICATIONS & AMPACITY CORRECTION FACTORS Voltage Colors for Cam Style Receptacles 1 - Black, Red, White & Green 3 - Black, Red, Blue, White and Green 4 - Brown, Orange, Yellow and Green 5 - Brown, Orange, Yellow, White and Green 6 - Black, Black, Black, White and Green TEMPERATURE CORRECTION FACTORS ** 3200A — 14 x 500 MCM 4000A — 16 x 500 MCM C - Long Barrel Compression S - 1/2” x 13 Threaded Stud (400A and below) O - Other (Specify) Sample Construction: 1600A, 208/120V, Wall Mount S Mechanical Lug permanent busbar connection Male cam style receptacle generator connection Phase Rotation Monitor, 2x Duplex GFCI, Generator Signal Terminal Block GDS-163W-LM-AC2H Size Stranding Strand Nominal OD Finished Nominal OD Weight lbs. / M FT Ampacity* Ambient Temp °C FACTOR Ambient Temp °F Number of Conductors Temperature Adjustment 8 168 x 30 0.150 0.485 162 80 21-25 1.04 70-77 4-6 80% 6 266 x 30 0.192 0.525 197 105 26-30 1.00 78-86 7-9 70% O - Other (Specify) 4 420 x 30 0.252 0.582 204 125 31-35 0.96 87-95 10-20 50% D - 1Ø 120V 30A NEMA L5‐30 Outlet 2 665 x 30 0.320 0.650 315 190 36-40 0.91 96-104 21-30 45% E - 1Ø 120V 50A Twist‐Lock Outlet 1 833 x 30 0.354 0.725 376 220 41-45 0.87 105-113 41-40 40% F - 1Ø 125/250V 50A Twist‐Lock Outlet (Add number after letter if requesting more than one) 1/0 1064 x 30 0.397 0.775 480 260 46-50 0.82 114-122 41+ 35% H - Generator Signal Terminal Wiring Block 2/0 1330 x 30 0.450 0.820 603 300 51-55 0.76 123-131 3/0 1691 x 30 0.510 0.880 716 350 56-60 0.71 132-140 4/0 2109 x 30 0.580 0.965 895 405 61-70 0.58 141-158 71-80 0.41 159-176 Generator Connection (Optional Loadbank Connection) (Other Options - List all after dash) M - Male Cam Style Receptacles (std) LF - Female Cam Style Receptacles A - Phase rotation monitor L - Mechanical Lugs LL - Mechanical Lug B - 1Ø 120V 20A Duplex Outlet C - 1Ø 120V 20A Duplex GFCI Outlet I - Stainless Steel construction J - Bottom conduit access (increased panel depth - contact factory for details) D RATING FOR CONDUIT OR TRAY APPLICATION K# - Kirk‐Key door interlock (# - number of key cylinders) L - Custom lug size or compression type 28% P - Custom powder coat color (Specify - ANSI grey standard) Adjustment factor for more than three current carrying conductors * For ambient temperatures other than 30 C (86 F) multiply the allowable ampacities stated above by the appropriate conversion factor. S - Special (explain) ** Indented into sheath: (UL) TYPE PPE 90OC DRY 75OC WET 2000V E204219 AWG 4/0 C(UL) PPC/TPE FT5 90OC 600v NOTES: For 400-800A choose up to 2 from B-E ***Values Listed are for single conductors, where the individual conductor is not installed in raceways or physical contact with each other except in the lengths not exceeding 24.0 inches. 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com For 1200-4000A choose up to 3 from B-E 20 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 21 manufacturing NOTES TRYSTAR PRODUCTION _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ 507.333.3990 • 866.TRYSTAR • fax 507.334.1683 • trystar.com 22 2917 Industrial Drive Faribault, Minnesota 55021 CUSTOM CABLE & POWER SOLUTIONS 507.333.3990 866.TRYSTAR trystar.com