WALTRON SERIES
Transcription
WALTRON SERIES
WALTRON SERIES Single Point Sample Conditioning Modules Waltron Series Single Point Sample Conditioning Modules help to lower temperature and pressure of single point samples providing versatility to your system. Modules can be used before continuous analysis instruments or used to obtain grab samples. The main benefits of using a sample conditioning module are to protect analyzers and personnel and to ensure analyzer accuracy. F EAT U R E S Modules are pre-engineered to your specifications Module delivered assembled with only cooling water, sample and drain connections required for start-up List of options accommodates conditioning for any sample Convenient stainless steel sink holds grab sample bottle and acts as drain Handles wide range of samples, pressures and temperatures for peak performance Unit is compact and lightweight Variety of analyzers can be mounted directly onto unit with larger plate BENEFITS Minimal maintenance Protection of instrumentation Ensure correct sampling conditions G E N E R A L S P E C I F I C AT I O N S S A M P L E S P E C I F I C AT I O N S Pressure: Low Pressure: 0 – 1000 psig / 70 bar; High Pressure: 1000 – 5000 psig / 350 bar Temperature: Low Temp: 0 – 450°F / 232°C; High Temp: up to 1000°F / 537°C Flow: Up to 1500 ml/min C O O L I N G WAT E R S P E C I F I C AT I O N S Pressure: 35 – 150 psig / 2.45 – 10.5 bar Temperature: Up to 100°F / 37°C Flow: 4 – 12 gpm / 15.14 – 45.43 ml/min Cooling water inlet/ outlet connections: from 3/8” FNPT to 3/4” FNPT S YS T E M S P E C I F I C AT I O N S Backplate: 17“ x 27“ / 43.1 x 68.58 cm; 304SS Grab sample sink: 304SS with 1/2” FNPT drain connection High pressure inlet valve: 1/4”OD compression type (for hot liquid) or 3/8”OD compression type (for steam). Inlet valve packing can be Teflon, PEEK or Grafoil. BNZ Coolant isolation and throttling valves: High temp thermal shut-off valve: High pressure reducing valve: 304SS (for 0 – 3000 psi) or 316SS (for > 3000 psi) 316SS Temperature gauge: 0 – 200°F / 93°C; 316SS Pressure gauge: 0 – 60 psig / 0 – 4.2 bar; 316SS Back pressure regulator: 0 – 50 psig / 0 – 3.5 bar; 316SS Analyzer flowmeter: 20 – 240 ml/min; acrylic and 316SS; with 1/4“ compression fitting outlet HOW TO ORDER: WALTRON SAMPLE CONDITIONING MODULE PRESSURE REDUCER TOTAL SAMPLE FLOW INDICATOR 1 (provide pressure & flow requirements) 0 Not included 1 Sample pressure up to 1000 psig / 70 bar 2 Sample pressure 1000 to 5000 psig / 350 bar 0 Not included 1 Included SAMPLE COOLER 0 Not included 1 Standard capacity 1.0 sq ft / 0.09 m2 2 Medium capacity 2.4 sq ft / 0.22 m2 3 High capacity 3.5 sq ft / 0.33 m2 SAMPLE SHUT-OFF VALVE L Sample temperature up to 450°F / 232°C M Sample temperature up to 600°F / 316°C H Sample temperature up to 1000°F / 537°C SAMPLE BLOWDOWN VALVE 0 Not included 1 Included PRESSURE & TEMPERATURE GAGES 0 Not included 1 Pressure gage 0 – 60 psig / 0 – 4.2 bar 2 Temperature gage 0 – 200°F / 0 – 93 bar 3 Pressure and temperature gage SAMPLE TO ANALYZER CONTROL 0 None required 1 Shut-off valve2 2 Flowmeter2 30 – 300 cc/min COOLING WATER CONTROL3 0 None 1 2-way inlet valve with relief valve 3 Sight flow indicator 1. The Total Flow Indicator is recommended as an indication of Cooler load. Cooler life can be extended by controlling total sample flow. 2. Includes Pressure Regulator. 3. An outlet Throttling Valve is included as standard. A Relief Valve is required with 2-way Inlet Valve. The Shut-Off Valve allows for Cooler isolation. The Sight Flow Indicator provides positive indication of coolant flow. WALTRON, L.L.C. 50 Tannery Road, PO Box 70, Whitehouse, NJ 08888-0070 Phone: 800-242-7353 • Outside the US: 908-534-5100 Fax: 908-534-5546 • www.waltron.net V.10.26.2012 WALTRON B.V. PO Box 7089, 5980 AB Panningen, The Netherlands Phone: +31-77-3082955 Fax: +31-77-3082956 • www.waltron.net