WALTRON SERIES

Transcription

WALTRON SERIES
WALTRON SERIES
Single Point Sample
Conditioning Modules
Waltron Series Single Point Sample Conditioning Modules help to
lower temperature and pressure of single point samples providing
versatility to your system. Modules can be used before continuous
analysis instruments or used to obtain grab samples. The main
benefits of using a sample conditioning module are to protect
analyzers and personnel and to ensure analyzer accuracy.
F EAT U R E S
Modules are pre-engineered to your specifications
Module delivered assembled with only cooling
water, sample and drain connections required for
start-up
List of options accommodates conditioning for
any sample
Convenient stainless steel sink holds grab sample
bottle and acts as drain
Handles wide range of samples, pressures and
temperatures for peak performance
Unit is compact and lightweight
Variety of analyzers can be mounted directly onto unit
with larger plate
BENEFITS
Minimal maintenance
Protection of instrumentation
Ensure correct sampling conditions
G E N E R A L S P E C I F I C AT I O N S
S A M P L E S P E C I F I C AT I O N S
Pressure:
Low Pressure: 0 – 1000 psig / 70 bar; High Pressure: 1000 – 5000 psig / 350 bar
Temperature:
Low Temp: 0 – 450°F / 232°C; High Temp: up to 1000°F / 537°C
Flow:
Up to 1500 ml/min
C O O L I N G WAT E R S P E C I F I C AT I O N S
Pressure:
35 – 150 psig / 2.45 – 10.5 bar
Temperature:
Up to 100°F / 37°C
Flow:
4 – 12 gpm / 15.14 – 45.43 ml/min
Cooling water inlet/
outlet connections:
from 3/8” FNPT to 3/4” FNPT
S YS T E M S P E C I F I C AT I O N S
Backplate:
17“ x 27“ / 43.1 x 68.58 cm; 304SS
Grab sample sink:
304SS with 1/2” FNPT drain connection
High pressure inlet valve:
1/4”OD compression type (for hot liquid) or 3/8”OD compression type (for steam).
Inlet valve packing can be Teflon, PEEK or Grafoil.
BNZ
Coolant isolation and
throttling valves:
High temp thermal
shut-off valve:
High pressure
reducing valve:
304SS (for 0 – 3000 psi) or 316SS (for > 3000 psi)
316SS
Temperature gauge:
0 – 200°F / 93°C; 316SS
Pressure gauge:
0 – 60 psig / 0 – 4.2 bar; 316SS
Back pressure regulator:
0 – 50 psig / 0 – 3.5 bar; 316SS
Analyzer flowmeter:
20 – 240 ml/min; acrylic and 316SS; with 1/4“ compression fitting outlet
HOW TO ORDER: WALTRON SAMPLE CONDITIONING MODULE
PRESSURE REDUCER
TOTAL SAMPLE FLOW INDICATOR 1
(provide pressure & flow requirements)
0 Not included
1 Sample pressure up to 1000 psig / 70 bar
2 Sample pressure 1000 to 5000 psig / 350 bar
0 Not included
1 Included
SAMPLE COOLER
0 Not included
1 Standard capacity 1.0 sq ft / 0.09 m2
2 Medium capacity 2.4 sq ft / 0.22 m2
3 High capacity 3.5 sq ft / 0.33 m2
SAMPLE SHUT-OFF VALVE
L Sample temperature up to 450°F / 232°C
M Sample temperature up to 600°F / 316°C
H Sample temperature up to 1000°F / 537°C
SAMPLE BLOWDOWN VALVE
0 Not included
1 Included
PRESSURE & TEMPERATURE GAGES
0 Not included
1 Pressure gage 0 – 60 psig / 0 – 4.2 bar
2 Temperature gage 0 – 200°F / 0 – 93 bar
3 Pressure and temperature gage
SAMPLE TO ANALYZER CONTROL
0 None required
1 Shut-off valve2
2 Flowmeter2 30 – 300 cc/min
COOLING WATER CONTROL3
0 None
1 2-way inlet valve with relief valve
3 Sight flow indicator
1. The Total Flow Indicator is recommended as an indication of Cooler load. Cooler life can be extended by controlling total sample flow.
2. Includes Pressure Regulator.
3. An outlet Throttling Valve is included as standard. A Relief Valve is required with 2-way Inlet Valve.
The Shut-Off Valve allows for Cooler isolation. The Sight Flow Indicator provides positive indication of coolant flow.