Digital Power Meter
Transcription
Digital Power Meter
SMART X835 Monitor and analysis your power consumption Measurement brings intelligent Three Phase Panel Mounting Multifunction Power Analyzer Features Introduction The Smart X835 is a new generation three phase multifunction panel meter,it can measure and display all major electronic parameters including voltage, frequency, current, power, active and reactive energy, imported and exported energy. Energy is measured in terms of kwh , kVArh. SMART X835 can be configured to work with a wide range of CTs,giving the unit a wide range of operation.Built-in interfaces provides pulse and RS485 Modbus RTU outputs. Configuration is password protected.It can be used not only in the electricity transmission and power distribution system but also in the power consumption measurement and analysis in high voltage and low voltage intelligent power grid. Measurement 1 Phase-Neutral Voltage V1,V2,V3 Phase-Phase Voltage V1-2,V2-3,V3-1 Current I1,I2,I3 Active Power P1,P2,P3,P_total Reactive Power Q1,Q2,Q3,Q_total Apparent Power S1,S2,S3,S_total Power Factor PF of L1/ L2/ L3,PF_total Frequency Hz Active Energy Ep_imp,Ep_exp,Ep_total Reactive Energy Eq_imp,Eq_exp,Eq_total Total Harmonic Distortion THD Max. Demand MD DIN96 x96 mm Panel Mounted Class 0.5 RS485 Mondus RTU Wide angle backlit display 2-60th Harmonic Distortion Easy installation and navigation Performance Criteria ≤85% Storage Humidity ≤95% Operating Temperature -20℃~+50℃ Storage Temperature -30℃~+70℃ International Standard IEC62053-21/IEC61010 Protection against Dust and Water IP51 Insulating Protective Class II 96mm Specification Voltage Input 55 m m Operating Humidity 96mm Dimensions 20~280V(L-N) 20~480V(L-L) Nominal Voltage(Un) 230(400)V (3~) Basic Current (Ib) 1A/5A Over Current Withstand 120% of Imax Starting Current 0.4%Ib Frequency Range 50~60Hz Auxiliary Power 85~275V AC/120~380V DC CT Primary 1~9999A PT Primar y 500000V Burden 0.36VA per phase Max at 600V 0.014VA per phase at 120 V Wiring Diagram Three Phase Three Wire LINE A B C 1A FUSE 5 l11 6 l12 2 1 3 4 Vn V3 V2 V1 7 l21 8 l22 9 l31 RS485 Communication G 10 l32 Power 11 12 13 LOAD Protocol Modbus RTU/ DL/T 645-2007 Bus Type R S 485 Baud Rate 1200/2400/4800/9600(default)/ 19200/38400/115200bps Address Range 1~247 Communication Distance 1000M Parity NONE L N Three Phase Four Wire LINE A B C N 1A FUSE Data Bit 8 Stop Bit 1 5 l11 6 l12 3 4 2 1 Vn V3 V2 V1 POWER 1% 17 18 19 20 Harmonic 13 0.5% 12 0.5% Real Time Demand 11 Reactive Demand 22 0.5% 21 Active Demand ALARM2 0.5% 0.2% RELAY OUTPUTS Power Factor Frequency DO 11 DO 12 DO 21 DO 22 Class 0.5/Class1.0 Class 1.0 N Active Energy Reactive Energy EO-PULSE 0.5% ALARM1 0.5% Real time Power PULSE OUTPUTS 0. 5% EP-PULSE Active Power Reactive Power S2 CCM 0.2% Dl2 Current 14 15 16 0.2% Dl1 LOAD Voltage L 10 l32 S1 G POWER Accuracy B 8 l22 9 l31 A RS-485 7 l21 More Info : http://www.autohunter.co.th Email : [email protected] Tel : 662-1925933-5,Fax : 662-1925932 2