26-a811 exterior det..

Transcription

26-a811 exterior det..
1
214"
2"
1
ALUCOBOND COMPOSITE
TRIM SUPPLIED BY SOBOTEC
FASTENERS AND SHIMS BY INSTALLER.
SHIM AS/IF REQUIRED.1 FASTENER, CLIP
TO SHEATHING/FRAMING, TYP.
4"
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
= SHIM GAP
FASTENERS AND SHIMS BY INSTALLER.
SHIM AS/IF REQUIRED.1 FASTENER, CLIP
TO SHEATHING/FRAMING, TYP.
PANEL WEEPS LOCATED
@6" FROM PANEL ENDS.
MINIMUM 2 PER PANEL.
SL2000 WALL TRACK @ 4" LONG
SUPPLIED BY SOBOTEC.WALL TRACK
AND STARTER CLIPS INSTALLED @ 16"
C/C. SL200 WALL TRACK CLIPS SHIPPED
PRE-PUNCHED FOR INSTALLATION.
SL2000 ALUCOBOND
REVEAL FINISH TO
MATCH PANEL
2340 GARDEN ROAD, SUITE 100
MONTEREY, CALIFORNIA 93940
PHONE: 831.649.4642
#12 x 1" HWH TEK SCREWS
SUPPLIED BY SOBOTEC. 1
FASTENER, CLIP TO PANEL, TYP.
#12 x 1" HWH TEK SCREWS
SUPPLIED BY SOBOTEC. 1
FASTENER, CLIP TO PANEL, TYP.
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
FAX: 831.649.3530
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
WWW.WRDARCH.COM
1
SCALE:
6" = 1'-0"
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
21 4"
FASTENERS AND SHIMS BY INSTALLER.
SHIM AS/IF REQUIRED.1 FASTENER, CLIP
TO SHEATHING/FRAMING, TYP.
6
6" = 1'-0"
SL2000 WALL TRACK @ 4" LONG
SUPPLIED BY SOBOTEC.WALL TRACK
AND STARTER CLIPS INSTALLED @ 16"
C/C. SL200 WALL TRACK CLIPS SHIPPED
PRE-PUNCHED FOR INSTALLATION.
#12 x 1" HWH TEK SCREWS
SUPPLIED BY SOBOTEC. 1
FASTENER, CLIP TO PANEL, TYP.
1
2 4"
SHIM GAP
115 16"
BLUESKIN WEATHER BARRIER
NOT BY SOBOTEC
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
CONTINUOUS SL2000 STARTER @144"
LONG SUPPLIED BY SOBOTEC. SL2000
STARTER SHIPPED PRE-PUNCHED FOR
FASTENERS @ 16" C/C.
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
SL2000 ALUCOBOND COMPOSITE
PANEL BY SOBOTEC
SL2000 ALUCOBOND
REVEAL FINISH TO
MATCH PANEL
PANEL WEEPS LOCATED @ 6" FROM
PANEL ENDS. MINIMUM 2 PER PANEL.
PANEL DIMENSION
3
8"
PANEL DIMENSION
INSTALLATION DIRECTION
2
SCALE:
6" = 1'-0"
FLASHING AND ROOF SYSTEM. NOT IN
SOBOTEC LTD. SCOPE OF WORK.
21 4"
5
SHIM GAP
115 16"
BLUESKIN WEATHER BARRIER
NOT BY SOBOTEC
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
7
SCALE:
16"
6" = 1'-0"
FASTENERS AND SHIMS BY
INSTALLER. SHIM AS/IF REQUIRED.
FASTENERS @ 24" C/C. (MINIMUM 2
PER FASTENED LENGTH)
CONTINUOUS SL2000 STARTER @144"
LONG SUPPLIED BY SOBOTEC. SL2000
STARTER SHIPPED PRE-PUNCHED FOR
FASTENERS @ 16" C/C.
SL2000 ALUCOBOND COMPOSITE
PANEL BY SOBOTEC
T/O STARTER
21 4"
3
115 16"
16" SHIM GAP
PANEL WEEPS LOCATED @ 6"
FROM PANEL ENDS. MINIMUM 2
PER PANEL.
FASTENERS AND SHIMS BY
INSTALLER. SHIM AS/IF REQUIRED.
FASTENERS @ 24" C/C. (MINIMUM 2
PER FASTENED LENGTH)
CONTINUOUS SL2000 STARTER @144"
LONG SUPPLIED BY SOBOTEC. SL2000
STARTER SHIPPED PRE-PUNCHED FOR
FASTENERS @ 16" C/C.
T/O STARTER
3
SCALE:
SL2000 ALUCOBOND COMPOSITE
PANEL BY SOBOTEC
011-541-006
FASTENERS AND SHIMS BY
INSTALLER. SHIM AS/IF REQUIRED.
FASTENERS @ 24" C/C. (MINIMUM 2
PER FASTENED LENGTH)
A.P.N. NO.:
16"
SAM LINDER AUTO GROUP
JAGUAR LAND ROVER MONTEREY
1711 DEL MONTE BOULEVARD
SEASIDE, CA 93955
5
ALTERNATE FASTENER
POSITION.
SAM LINDER AUTO GROUP
JAGUAR LAND ROVER MONTEREY REMODEL
SCALE:
6" = 1'-0"
JOB NO.
12042
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
ALUCOBOND COMPOSITE TRIM
SUPPLIED BY SOBOTEC
PRINT DATE:
PLOT DATE:
8.8.2012
DRAWN BY:
JTI
CHECKED BY:
FD / MN
SET ISSUED:
08-08-12
SHOP-FASTENED
BUTT-JOINT CLIP
8
SCALE:
BUILDING PERMIT
SUBMITTAL
6" = 1'-0"
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
FASTENERS AND SHIMS BY
INSTALLER. SHIM AS/IF REQUIRED.
FASTENERS @ 24" C/C. (MINIMUM 2
PER FASTENED LENGTH)
4
1116"
ROOFCAP
SCALE:
6" = 1'-0"
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
BLUESKIN WEATHER BARRIER
NOT BY SOBOTEC
1
ALUCOBOND COMPOSITE
COPING SUPPLIED BY
SOBOTEC
4"
- SHIM GAP
O.R.=9"
FASTENERS AND SHIMS BY INSTALLER.
SHIM AS/IF REQUIRED.1 FASTENER, CLIP
TO SHEATHING/FRAMING, TYP.
PANEL WEEPS LOCATED
@6" FROM PANEL ENDS.
MINIMUM 2 PER PANEL.
B.E.
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
FASTENERS AND SHIMS BY
INSTALLER. SHIM AS/IF REQUIRED.
FASTENERS @ 24" C/C. (MINIMUM 2
PER FASTENED LENGTH)
#12 x 1" HWH TEK SCREWS
SUPPLIED BY SOBOTEC. 1
FASTENER, CLIP TO PANEL, TYP.
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
SL2000 WALL TRACK @ 4" LONG
SUPPLIED BY SOBOTEC.WALL TRACK
AND STARTER CLIPS INSTALLED @ 16"
C/C. SL200 WALL TRACK CLIPS SHIPPED
PRE-PUNCHED FOR INSTALLATION.
#12 x 1" HWH TEK SCREWS
SUPPLIED BY SOBOTEC. 1
FASTENER, CLIP TO PANEL, TYP.
TYVEK "COMMERCIAL-WRAP"
SUPPLIED BY SOBOTEC.
ASSURANCE OF A/V BARRIER
CONTINUITY, NOT BY SOBOTEC
9
SCALE:
1-1/2" = 1'-0"
5
SCALE:
6" = 1'-0"
SHEET NAME:
SL2000 ALUCOBOND
REVEAL FINISH TO
MATCH PANEL
EXTERIOR
DETAILS
SL2000 ALUCOBOND
COMPOSITE PANEL
BY SOBOTEC
SHEET NO.:
A811
21 4"
10
B.E.
SCALE:
6" = 1'-0"
FILE NAME.:

Similar documents

AKER - Bienvenue au Studio M Design

AKER - Bienvenue au Studio M Design Whether they want a gentle, reassuring caress or a deep, tension relieving rubdown, this is

More information