26-a811 exterior det..
Transcription
26-a811 exterior det..
1 214" 2" 1 ALUCOBOND COMPOSITE TRIM SUPPLIED BY SOBOTEC FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED.1 FASTENER, CLIP TO SHEATHING/FRAMING, TYP. 4" SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC = SHIM GAP FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED.1 FASTENER, CLIP TO SHEATHING/FRAMING, TYP. PANEL WEEPS LOCATED @6" FROM PANEL ENDS. MINIMUM 2 PER PANEL. SL2000 WALL TRACK @ 4" LONG SUPPLIED BY SOBOTEC.WALL TRACK AND STARTER CLIPS INSTALLED @ 16" C/C. SL200 WALL TRACK CLIPS SHIPPED PRE-PUNCHED FOR INSTALLATION. SL2000 ALUCOBOND REVEAL FINISH TO MATCH PANEL 2340 GARDEN ROAD, SUITE 100 MONTEREY, CALIFORNIA 93940 PHONE: 831.649.4642 #12 x 1" HWH TEK SCREWS SUPPLIED BY SOBOTEC. 1 FASTENER, CLIP TO PANEL, TYP. #12 x 1" HWH TEK SCREWS SUPPLIED BY SOBOTEC. 1 FASTENER, CLIP TO PANEL, TYP. SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC FAX: 831.649.3530 SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC WWW.WRDARCH.COM 1 SCALE: 6" = 1'-0" TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC 21 4" FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED.1 FASTENER, CLIP TO SHEATHING/FRAMING, TYP. 6 6" = 1'-0" SL2000 WALL TRACK @ 4" LONG SUPPLIED BY SOBOTEC.WALL TRACK AND STARTER CLIPS INSTALLED @ 16" C/C. SL200 WALL TRACK CLIPS SHIPPED PRE-PUNCHED FOR INSTALLATION. #12 x 1" HWH TEK SCREWS SUPPLIED BY SOBOTEC. 1 FASTENER, CLIP TO PANEL, TYP. 1 2 4" SHIM GAP 115 16" BLUESKIN WEATHER BARRIER NOT BY SOBOTEC TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC CONTINUOUS SL2000 STARTER @144" LONG SUPPLIED BY SOBOTEC. SL2000 STARTER SHIPPED PRE-PUNCHED FOR FASTENERS @ 16" C/C. SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC SL2000 ALUCOBOND REVEAL FINISH TO MATCH PANEL PANEL WEEPS LOCATED @ 6" FROM PANEL ENDS. MINIMUM 2 PER PANEL. PANEL DIMENSION 3 8" PANEL DIMENSION INSTALLATION DIRECTION 2 SCALE: 6" = 1'-0" FLASHING AND ROOF SYSTEM. NOT IN SOBOTEC LTD. SCOPE OF WORK. 21 4" 5 SHIM GAP 115 16" BLUESKIN WEATHER BARRIER NOT BY SOBOTEC TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC 7 SCALE: 16" 6" = 1'-0" FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED. FASTENERS @ 24" C/C. (MINIMUM 2 PER FASTENED LENGTH) CONTINUOUS SL2000 STARTER @144" LONG SUPPLIED BY SOBOTEC. SL2000 STARTER SHIPPED PRE-PUNCHED FOR FASTENERS @ 16" C/C. SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC T/O STARTER 21 4" 3 115 16" 16" SHIM GAP PANEL WEEPS LOCATED @ 6" FROM PANEL ENDS. MINIMUM 2 PER PANEL. FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED. FASTENERS @ 24" C/C. (MINIMUM 2 PER FASTENED LENGTH) CONTINUOUS SL2000 STARTER @144" LONG SUPPLIED BY SOBOTEC. SL2000 STARTER SHIPPED PRE-PUNCHED FOR FASTENERS @ 16" C/C. T/O STARTER 3 SCALE: SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC 011-541-006 FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED. FASTENERS @ 24" C/C. (MINIMUM 2 PER FASTENED LENGTH) A.P.N. NO.: 16" SAM LINDER AUTO GROUP JAGUAR LAND ROVER MONTEREY 1711 DEL MONTE BOULEVARD SEASIDE, CA 93955 5 ALTERNATE FASTENER POSITION. SAM LINDER AUTO GROUP JAGUAR LAND ROVER MONTEREY REMODEL SCALE: 6" = 1'-0" JOB NO. 12042 SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC ALUCOBOND COMPOSITE TRIM SUPPLIED BY SOBOTEC PRINT DATE: PLOT DATE: 8.8.2012 DRAWN BY: JTI CHECKED BY: FD / MN SET ISSUED: 08-08-12 SHOP-FASTENED BUTT-JOINT CLIP 8 SCALE: BUILDING PERMIT SUBMITTAL 6" = 1'-0" SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED. FASTENERS @ 24" C/C. (MINIMUM 2 PER FASTENED LENGTH) 4 1116" ROOFCAP SCALE: 6" = 1'-0" SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC BLUESKIN WEATHER BARRIER NOT BY SOBOTEC 1 ALUCOBOND COMPOSITE COPING SUPPLIED BY SOBOTEC 4" - SHIM GAP O.R.=9" FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED.1 FASTENER, CLIP TO SHEATHING/FRAMING, TYP. PANEL WEEPS LOCATED @6" FROM PANEL ENDS. MINIMUM 2 PER PANEL. B.E. TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC FASTENERS AND SHIMS BY INSTALLER. SHIM AS/IF REQUIRED. FASTENERS @ 24" C/C. (MINIMUM 2 PER FASTENED LENGTH) #12 x 1" HWH TEK SCREWS SUPPLIED BY SOBOTEC. 1 FASTENER, CLIP TO PANEL, TYP. SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC SL2000 WALL TRACK @ 4" LONG SUPPLIED BY SOBOTEC.WALL TRACK AND STARTER CLIPS INSTALLED @ 16" C/C. SL200 WALL TRACK CLIPS SHIPPED PRE-PUNCHED FOR INSTALLATION. #12 x 1" HWH TEK SCREWS SUPPLIED BY SOBOTEC. 1 FASTENER, CLIP TO PANEL, TYP. TYVEK "COMMERCIAL-WRAP" SUPPLIED BY SOBOTEC. ASSURANCE OF A/V BARRIER CONTINUITY, NOT BY SOBOTEC 9 SCALE: 1-1/2" = 1'-0" 5 SCALE: 6" = 1'-0" SHEET NAME: SL2000 ALUCOBOND REVEAL FINISH TO MATCH PANEL EXTERIOR DETAILS SL2000 ALUCOBOND COMPOSITE PANEL BY SOBOTEC SHEET NO.: A811 21 4" 10 B.E. SCALE: 6" = 1'-0" FILE NAME.:
Similar documents
AKER - Bienvenue au Studio M Design
Whether they want a gentle, reassuring caress or a deep, tension relieving rubdown, this is
More information