Product Brochure
Transcription
Product Brochure
instruments MODULE Arrhythmias Simulation Calibration Certificate Traceability & Conformity Technical Specifications Cardiac Simulation The TechPatient CARDIO ECG simulator stands among its competitors for generating realistic cardiac waveforms, an advantage that gives you the certainty that any test conducted with this simulator will be repeatable with a human patient. Twelve leads ECG simulation is suitable to test modern diagnostic equipment, including waveform recognition devices. Advanced Analysis Using the TechPatient CARDIO EKG simulator you will also be able to test the noise filtering systems and beat rate measurement functions of the diagnostic device under test. To perform noise testing, multiple real life noise sources are included. You can select between line noise (related to poor ground connections), base line wandering (related to poor electrode conductivity), muscle tremor, power supply noise and more. The beat rate setup function combines the selection of an arbitrary rate with the addition of beat to beat variability, a key performance testing to make sure diagnostic devices operate properly under critical conditions. http://www.heinstruments.com/ [email protected] Waveform ECG, Ritmic*, Sine, Triangular, Square, Pulsed and Baseline Beat Rate 20 BPM to 300 BPM 0% to 20%* deviation Frequency 1/8Hz to 120Hz Noise Sources Line, Ripple, Random, Baseline W., Tremor Amplitude 0.5mV, 1mV, 2mV, 4mV 0% to 20%* deviation Leads 12 (Snap / Banana / Pin) Hi-Signal Output 200x Lead II plus DC Output Impedance 2200Ù unipolar Power Source Standard 9V Battery or 9VDC Adapter (NOT INCLUDED) Product Size 150mm x 90mm x 26mm Approx. Weight 400gr instruments simulador de ecg, simulador de ekg, simulador de paciente, simulador cardiaco, ecg simulator, ekg simulator, patient simulator, cardiac simulator Features in TechPatient CARDIO Version 3 Biopotential multi-connectors Fluke Biomedical Test ESA612 ESA620 Electrical Safety Analyzer ULT800 Ultrasound Transducer Leakage Current Tester medTester 5000C Automated Biomedical Equipment Test System 180 175 Electrical Safety Analyzer 601 Pro SeriesXL International Safety Analyzer PS400 PS415 PS410 ECG/Arrythmia Simulator DataSim 6100 medSim 300B MPS450 Patient Simulator PS420 Multiparameter Patient ECG Simulator PS320 Fetal Simulator Datrend Systems 10A ECG Simulator 20A ECG /Arrhythmia Simulator AMPS-1 Advanced Modular Patient Simulator Serviciencia Ferronato FC3D ECG Simulator FC12D Simulador de ECG Simulaids Interactive ECG Simulator Code Simulator 12 Lead Arrhythmia Simulator Rigel 333 Patient Simulator UNI-SiM Vital Signs Simulator Symbio Rhythm Simulator CS1201 Simulator CS301 Simulator VitalSim Arrhythmia Trainer Netech MINISIM 1000 ADVANCED Multi-Parameter Simulator MINISIM 1000 BASIC Arrhythmia Simulator 330 - EEG Simulator Nasco Code Simulator 12-Lead Arrhythmia Simulator – Marquette Physio Quick Combo ZOLL Large view Rhythm Display Interface R2 Medi Cal Instruments, Inc. Model 430, 12 Lead ECG Simulator Model 430B, 12 Lead ECG Simulator Series 500 Precision Patient Simulator Müller & Sebastiani Elektronik GmbH phantom 320 ECG Simulator MS410 ECG Simulator MS400 Calibration Signal Generator Laerdal HeartSim 200 QUIK-COMBO BC Biomedical PS-2110 Patient Simulator PS-2200 Series Patient Simulator BC Biomedical MaxiSim BAPCO PS97S Universal Patient Simulator PS-2005 Patient Simulator 2006 Patient Simulator NIBP Series Pronk Technologies SL-8 SimSlim® Multi-Parameter Patient Simulator BCI 1606 Oximeter/ECG Simulator R&D Mediq Handy Sim HS-20 Handy Sim HS-14 Handy Sim HS-15 Fogg Systems M310 M311 Vacumed SME-20 SME-30 MGY-E01 Computerized ECG Simulator Alibaba Globalspec ebay UN-ES-3 DFCI simulador de ecg simulador de ekg simulador de paciente simulador cardiaco simulador biomédico ensayo biomédico simulador de electromedicina simulador de corazón generador de ondas cardiacas simulador de qrs pqrst pqrstu simulador de ritmos simulador de ritmo cardiaco simulador multiparamétrico analizador de seguridad eléctrica generador de señales de calibración de equipamiento medico calibración de monitores de terapia calibración de grabadores holter calibración de electrocardiógrafos simulador de arritmias simulador acls als bls simulador ecg de precisión simulador automatico tecnología biomédica onda t onda p onda r onda qrs complejo qrs ancho complejo qrs angosto 12 derivaciones 5 derivaciones 3 derivaciones R L F N C1 C2 C3 C4 C5 C6 CX CY CZ RL LL RA LA V1 V2 V3 V4 V5 V6 VX VY VZ cable de alta señal circuito simulador conversor AD ADC conversor DA DAC amplificador de instrumentación atenuador calibrado rechazo ruido de línea interferencia modo común señal diferencial lms filtrado adaptativo filtro fir iir fft fourier onditas escala instrumentación detección latidos algoritmo reconocimiento eigen eigenlatidos análisis de componentes principales kit de desarrollo placa de evaluación microcontrolador digital analogico dsc procesamiento de señales transformada señal temporal broche banana pin din 3.0 4mm 3mm 2mm 6mm 1/8” cable de paciente conector biopotenciales Ecg simulator ekg simulator patient simulator cardiac simulador heart simulator biomedical simulator biomedical test equipment electromedical simulator heart wave waveform generator qrs simulator rhythms simulator heart rhythm simulator multiparameter electrical safety analyzer calibration signal generator medical equipment calibration diagnostic equipment calibration patient monitor calibration ecg recorder calibration holter calibration arrhythmia simulator als acls bls simulator precision simulator automated bioemedical technology T wave P wave Q wave QRS wave wide QRS complex narrow qrs complex U wave 12 leads 5 leads 3 leads R L F N C1 C2 C3 C4 C5 C6 CX CY CZ RL LL RA LA V1 V2 V3 V4 V5 V6 VX VY VZ high signal cable preamplified simulator circuit DA DAC converter AD ADC converter instrumentation amplifier calibrated attenuator line noise rejection interference common mode differential signal lms adaptive filter fir iir fourier fft wavelet scale beat detection algorithm recognition eigen eignebeats principal component analysis development kit evaluation board dsp texas instruments national instruments analog devices microcontroller digital signal processing time series signal ec13 aami aha iec iso 17025 9001 snap banana pin din3.0 4mm 3mm 2mm 6mm 1/8” patient cable cabo connector biopotential The new multi-connectors give the simulator enhanced compatibility, enabling its connection to 4mm snap, 4mm banana and 2mm pin patient cables. You’ll no longer need expensive adapters that degrade reliability and performance. Neoprene travel holster Alabama Alaska American Samoa Arizona Arkansas California Colorado Connecticut The new Neoprene travel holster the Hawaii Idaho Illinois Indiana Delaware District of Columbia Floridaprotects Georgia Guam Iowa Kansas Kentucky Louisiana Maine Maryland simulators from shocks and moisture while Massachusetts Michigan Minnesota Mississippi Missouri Montana Nebraska Nevada New Hampshire easing its New transport. Its flexible New Jersey Mexico New York Northstructure Carolina North Dakota Northern Marianas Islandsyou Ohiocarry Oklahoma Oregon Puerto Rico Rhode Island helps cables or Pennsylvania even a spare South Carolina South Dakota Tennessee Texas Utah Vermont Virginia Virgin Islands battery. Washington West Virginia Wisconsin Wyoming Attach it to your belt to have your simulator at hand every time you need it. Retail box for global market The new retail product box enables our customers to resell the simulator in the US and other global markets. It includes the UPC product barcode, FCC exemption declaration and an eye-catching graphic design that will help you boost your sales. http://www.heinstruments.com/ [email protected] +1-866-921-4971 instruments MODULE Arrhythmias Simulation Module The Ritmic MODULE is an arrhythmias simulation sofware module installed on demand to the TechPatient CARDIO V3 ECG simulator. The following is a list of the simulated rhythms. Additional rhythms can also be included. Please contact us at [email protected] for specific quotation. [email protected] Click to Play Video w Normal Sinus Rhythm w Sinus Bradycardia w Sinus Tachycardia w Sinus Respiratory Arrhythmia w Sinus Exit Block w Sinus Arrest w 1st Degree AV Block w 2nd Degree Type I Av Block w 2nd Degree Type II Av Block w 2nd Degree 2:1 Av Block w 3rd Degree Av Block w Left Bundle Branch Block w Right Bundle Branch Block w Sinus Rhythm with PAC w Sinus Rhythm with PNC / PJC w Sinus Rhythm with PVC w Supraventricular Tachycardia w Atrial Flutter w Atrial Fibrillation w Atrial Bigeminy w Atrial Trigeminy w Nodal (Junctional) Rhythm w Accelerated Nodal (Junctional) Rhythm w Nodal (Junctional) Tachycardia w Nodal (Junctional) Bigeminy w Nodal (Junctional) Trigeminy w Idioventricular Rhythm w Accelerated Idioventricular Rhythm w Monomorphic Ventricular Tachycardia w Torsades de Pointes w Ventricular Fibrillation w Ventricular Bigeminy w Ventricular Trigeminy w Wolf-Parkinson-White Syndrome w Normal Pediatric ECG w Long QT Segment Syndrome w ST Segment Elevation w ST Segment Depression w Pacemaker Rhythm - Atrial Paced w Pacemaker Rhythm - Ventricular Paced w Pacemaker Rhythm - AV Sequential w Pacemaker Not Captured w Pacemaker Not Functioning w Pacemaker On Demand w Asystole Automatic Sequencing Automatic sequencing is specially useful for product show off on trade fairs and events. Random sequencing has also been included for medical educators and paramedic instructors to train and challenge their students to recognize the simulated arrhythmia. The simulated rhythm strip changes every 10 seconds with a 1 second flatline pause in between. http://www.heinstruments.com/ [email protected] +1-866-921-4971 Calibration Certificate The calibration of our devices includes: Declaration of results traceability to national standards. Declaration of conformity to manufacturing specifications. Test results with their respective associated uncertainties. Calibration Certificate Sample Specific Calibration Procedure SP01EN Traceability to National Standards The measurement instruments used for device calibration are traceable to national standards. The time standard has been calibrated by a NIST traceable laboratory, while the voltage standard has been calibrated by an OAA / INTI SAC accredited laboratory. The calibration certificates of this time and voltage standards are available to our customers upon request to [email protected]. Factory Calibration Certificate The additional cost for the purchase of a TechPatient CARDIO V3 with the calibration certificate is US$ 35.-. To purchase the certificate please contact us at [email protected] before purchasing the product. You can also add it to your shopping cart before checking out. Requests received after product purchase will be accepted or rejected at HE Instruments option based on the status of the order. http://www.heinstruments.com/ [email protected] +1-866-921-4971 Mode Base