CMY-Y100VBK2, Y200VBK2, Y300VBK2 Outdoor
Transcription
CMY-Y100VBK2, Y200VBK2, Y300VBK2 Outdoor
WT05134X02 (2) Accessory piping parts MITSUBISHI ELECTRIC MULTI AIR CONDITIONERS OPTIONAL PARTS Model CMY-Y100VBK2, Y200VBK2, Y300VBK2 Outdoor Twinning Kit Installation Manual CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 • For your safety, thoroughly read the following instructions prior to installation. WARNING Incorrect handling can result in death or serious injury. CAUTION Incorrect handling can result in bodily injury and/or structure damage. Properly install all parts according to the instructions in the Installation Manual. • Improper installation may result in refrigerant gas leakage and equipment damage. • If the wrong twinning pipe or wrong size connecting pipe is used, air conditioning performance will suffer. Do not make any modifications or alterations. Consult your dealer for repair. When installing or relocating the unit, check that no substance other than the specified refrigerant (R410A) enters the refrigerant circuit. After installation, check for a refrigerant leak. • If leaked refrigerant comes in contact with a heat source, such as a fan heater, stove, or electric grill, toxic gases will be generated. PUHY-**Y(S)HM Do not touch the refrigerant pipes and refrigerant circuit components with bare hands during and immediately after operation. • During or immediately after operation, certain parts of the unit such as pipes and compressor may be either very cold or hot, depending on the state of the refrigerant in the unit at the time. To reduce the risk of frostbites and burns, do not touch these parts with bare hands. PUHY-**T(S)HM PUHY-**Y(S)HMU 1. Confirming the Package Contents Twinning kit Twinning kit The following twinning and accessory piping parts are included with the Twinning Kit (CMYY100VBK2, CMY-Y200VBK2, and CMY-Y300VBK2). Verify that all items are present before starting installation. After checking, prepare the twinning kit by connecting the twinning pipes B, C, and D to the twinning pipe A. *Always use the twinning pipes included in the kit when preparing the twinning kit. If the pipes on site do not fit the parts in the kit, use the accessory piping parts listed below. L-shape pipe Dd(After L-shape pipe (Afterthe the twinning) twinning) Insulation Insulationcover cover Twinning TwinningaA PUHY-**T(S)HMU PUHY-**Y(S)HMC b (Before twinning) Pipe c (After the twinning) Pipe Pipe B (Before the the twinning) Pipe C (After the twinning) (1) Twinning pipes (Unit: mm[in]) Label Liquid A Gas D Liquid C Gas B Liquid Second row A (Red) Liquid First row C (Red) Gas Second row D (Red) Gas First row B (Red) Twinning A CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] Pipe B (Before the twinning) OD15.88[5/8]-ID15.88[5/8] L83[3-9/32] OD28.58[1-1/8]-ID28.58[1-1/8] L342[13-15/32] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD31.75[1-1/4]-ID34.93[1-3/8] L337[13-9/32] OD15.88[5/8]-ID19.05[3/4] L85[3-3/8] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD28.58[1-1/8]-ID34.93[1-3/8] L337[13-9/32] OD31.75[1-1/4]-ID38.1[1-1/2] L339[13-3/8] OD15.88[5/8]-ID12.7[1/2] (2) Gas OD34.93[1-3/8]-ID41.28[1-5/8] Liquid OD12.7[1/2]-ID9.52[3/8] OD12.7[1/2]-ID15.88[5/8] (2) OD15.88[5/8]-ID9.52[3/8] OD15.88[5/8]-ID12.7[1/2] Gas OD28.58[1-1/8]-ID22.2[7/8] (3) OD38.1[1-1/2]-ID41.28[1-5/8] OD28.58[1-1/8]-ID19.05[3/4] (2) OD38.1[1-1/2]-ID34.93[1-3/8] Outdoor unit Outdoor unit 1 1 Outdoor unit2 2 Outdoor unit Pipe C (After the twinning) L-shape pipe D (After the twinning) OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD25.4[1]-ID22.2[7/8] OD25.4[1]-ID22.2[7/8] L190[7-1/2] OD15.88[5/8]-ID15.88[5/8] OD15.88[5/8]-ID15.88[5/8] L123[4-27/32] OD28.58[1-1/8]-ID28.58[1-1/8] OD28.58[1-1/8]-ID28.58[1-1/8] L192[7-9/16] OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD15.88[5/8]-ID19.05[3/4] OD15.88[5/8]-ID15.88[5/8] L125[4-15/16] OD25.4[1]-ID28.58[1-1/8] OD25.4[1]-ID28.58[1-1/8] L192[7-9/16] OD28.58[1-1/8]-ID34.93[1-3/8] OD28.58[1-1/8]-ID28.58[1-1/8] L187[7-3/8] Insulation cover C PUHY-**Y(S)HC Instruction Small Large Small A0 P500 P550 P600 P650 P700 P750 P800 P850 P900 EP400 EP450 EP500 EP550 EP600 EP650 HP400 HP500 P500 P550 P600 P650 P700 P750 P800 P850 P900 P144 P168 P192 P216 P240 P144 P168 P192 P216 P240 HP144 HP192 HP400 HP500 P450(-AH) P500 P550 P600 P650 P700 P750 P800 P850 P900 Ee c Aa To Indoor unit unit To Indoor Liquid twinning pipe To Indoor unit unit To Indoor Gas twinning pipe Gas twinning pipe Liquid twinning pipe Ff d Bb 2 Two outdoor units 1 Two outdoor units Package unit name Outdoor unit 1 Component unit name Outdoor unit 2 OutIdoor Twinning Kit Liquid A Indoor unit~Twinning pipe Gas B * See the Installation Manual that came with the outdoor unit for installation instructions. Section Liquid D CAUTION Model OD22.2[7/8]-ID19.05[3/4] (2) 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. • Any presence of foreign substance or air can cause abnormal pressure rise or explosion. • Plastic bags can pose suffocation and choking hazards: keep them out of the reach of children. Tear the plastics bags before disposing of them. OD15.88[5/8]-ID12.7[1/2] OD22.2[7/8]-ID28.58[1-1/8] (1) Two outdoor units Only a dealer or qualified technician should perform installation. Properly dispose of packing materials. OD12.7[1/2]-ID9.52[3/8] (2) Gas 2. Selecting the Correct Size Refrigerant Pipes and Using the Twinning Kit WARNING • If refrigerant leaks and comes in contact with an open flame, toxic gases will be generated. Liquid • Refrigerant pipes other than the ones provided in the kit. • Heat-resistant insulation material (for field-supplied refrigerant pipes) • Insulation cover tape • Thoroughly read the following “Safety Precautions” to ensure proper installation. • Observe the following important safety precautions at all times. • Hazards that can occur from incorrect handling are classified by the symbols below: In the event of a refrigerant leak, thoroughly ventilate the room. Supplied pipe (3) List of field-supplied parts Safety Precautions • Improper installation may result in water leakage, electric shock, or fire. (Unit: mm[in]) Section A0 B0 C0 D0 E0 F0 B0 P250 P300 P350 P350 P350 P400 P450 P450 P450 EP200 P250 EP300 EP300 EP300 P350 HP200 HP250 P250 P300 P350 P350 P350 P400 P450 P450 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 HP72 HP96 HP200 HP250 P250 P250 P300 P350 P350 P350 P400 P400 P450 P450 C0 P250 P250 P250 P300 P350 P350 P350 P400 P450 EP200 EP200 EP200 P250 EP300 EP300 HP200 HP250 P250 P250 P250 P300 P350 P350 P350 P400 P450 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 HP72 HP96 HP200 HP250 P200 P250 P250 P250 P300 P350 P350 P400 P400 P450 Liquid C or E A2 B2 C2 D2 E2 F2 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit (Unit: mm[in]) F0 D0 E0 CMY-Y100VBK2 ø15.88 [5/8] CMY-Y200VBK2 ø19.05 [3/4] ø28.58 [1-1/8] ø34.93 [1-3/8] ø41.28 [1-5/8](*) ø12.7[1/2] PUHY-**YHM CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y200VBK2 CMY-Y100VBK2 PUHY-**THM ø34.93 [1-3/8] ø19.05 [3/4] ø41.28 [1-5/8](*) PUHY-**YHMU ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**THMU CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y200VBK2 ø15.88 [5/8] ø28.58 [1-1/8] ø15.88 [5/8] ø15.88 [5/8] ø28.58 [1-1/8] ø28.58 [1-1/8] PUHY-**YHMC ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**YHC ø34.93 [1-3/8] ø19.05 [3/4] A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8] EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8] P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) Outdoor unit Outdoor unit 1 1 ø41.28 [1-5/8](*) B1 B2 B3 P300 ø12.7 [1/2] ø22.2 [7/8] EP300 ø12.7 [1/2] ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P300 ø12.7 [1/2] ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] HP96 ø9.52 [3/8](*) ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P250 ø9.52 [3/8](*) ø22.2 [7/8] Gas D or F A3 B3 C3 D3 E3 F3 (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) – D1 D2 D3 P400 ø15.88 [5/8] ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8] ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) P120 ø12.7 [1/2] ø22.2 [7/8] P120 ø12.7 [1/2] ø22.2 [7/8] – P400 ø15.88 [5/8] ø28.58 [1-1/8] – P450 ø15.88 [5/8] ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – P300 ø12.7 [1/2] ø22.2 [7/8] P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8] ø28.58 [1-1/8] P450 ø15.88 [5/8] ø28.58 [1-1/8] Outdoor unit Outdoor unit 2 2 Outdoor unit Outdoor unit 3 3 (2) Three outdoor units Large 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. 1 (This sheet) Small Small Large Large cC Gg eE f twinning Liquid 1Liquid twinning pipe pipe 1 D d Hh F Ii Jj twinning pipe 1 Gas 1Gas twinning pipe Aa To Indoor To Indoor unit unit Liquid twinning pipe 2 To Indoor unit Gas twinning pipe 2 Liquid 2 twinning pipe Bb To Indoor unit Gas 2 twinning pipe 1 3 Three outdoor units Package unit name Outdoor unit1 Component unit name Outdoor unit2 Outdoor unit3 Outdoor Twinning Kit Liquid A Indoor unit~Twinning pipe2 Gas B Liquid C Twinning pipe1~Twinning pipe2 Gas D PUHY-**Y(S)HM PUHY-**T(S)HM PUHY-**Y(S)HMU PUHY-**T(S)HMU PUHY-**Y(S)HC A0 P950 P1000 P1050 P1100 P1150 P1200 P1250 EP700 EP750 EP800 EP850 EP900 P950 P1000 P1050 P1100 P1150 P1200 P1250 P264 P288 P312 P336 P360 P264 P288 P312 P336 P360 P850(-AH) P900(-AH) P950 P1000 P1050 P1100 P1150 P1200 P1250 B0 P400 P400 P400 P400 P450 P450 P450 EP300 EP300 EP300 EP300 EP300 P400 P400 P400 P400 P450 P450 P450 P120 P120 P120 P120 P120 P120 P120 P120 P120 P120 P350 P350 P400 P400 P400 P400 P400 P400 P450 C0 P300 P300 P350 P350 P350 P400 P450 EP200 P250 EP300 EP300 EP300 P300 P300 P350 P350 P350 P400 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 P300 P300 P300 P300 P350 P350 P400 P400 P450 4 Three outdoor units A0 B0 C0 D0 E0 F0 G0 H0 I0 D0 P250 P300 P300 P350 P350 P350 P350 EP200 EP200 EP200 P250 EP300 P250 P300 P300 P350 P350 P350 P350 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 P200 P250 P250 P300 P300 P350 P350 P400 P350 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit E0 F0 G0 (Unit: mm[in]) H0 I0 A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8](*) EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] PUHY-**YHM ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) PUHY-**THM PUHY-**YHMU PUHY-**THMU ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 PUHY-**YHC Liqrid E or G or I A2 B2 C2 D2 E2 F2 B1 B2 B3 P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) EP300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) 2 3. Pipe Connection Example Gas F or H or J A3 B3 C3 D3 E3 F3 Connect the pipes between outdoor units, referencing the figures below. <For two outdoor units> (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8] – D1 D2 D3 P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P300 ø12.7 [1/2](*) ø22.2 [7/8](*) P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – P450 – – – ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8](*) ø28.58 [1-1/8] P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – – – Field piping Field-supplied pipe Twinning Twinning kit kit Field piping pipe Field-supplied The length of the straight pipe must Straight pipe mm [19-11/ be 500 mm (19that inch)isor500 longer. 16 in] or more – <For three outdoor units> Field pipingpipe Field-supplied ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] Twinning Twinning kit kit Field piping pipe Field-supplied Twinning kit Twinning kit Straight pipe of that 500 mm The length theisstraight pipe must [19-11/16 in] or more be 500 mm (19 inch) or longer. (3) Slope of twinning pipes Make sure the slope of the twinning pipes are at an angle within ±15° to the horizontal plane. If the slope exceeds the specified angle, the unit may be damaged. The length of the straight pipe must be 500 mm (19 that inch)isor500 longer. Straight pipe mm [19-11/ 16 in] or more Note: Refer to the figure below for the installation Note: See the of following drawing position the twinning pipe.for the fitting position of the twinning pipe. Twinning Reducerpipe Use the pipes supplied in the twinning kit, and make sure the section of the field-supplied pipe that connects to the twinning pipe has at least 500 mm [19-11/16 in] of straight section. (The section of the fieldsupplied pipe that connects to the twinning pipe must have at least 500 mm [19-11/16 in] of straight section.) If the straight section is less than 500 mm [19-11/16 in], it may result in equipment damage. 4. Insulation Cover Installation Install the insulation cover on the twinning kit after brazing the pipes and twinning kit. Insulate all refrigerant pipes. Insulate the liquid and gas pipes separately, and pipes located inside the unit as well as the outside. Use heat-resistant insulation material (Heat resistant: at least 120 °C [248 °F], Thickness: liquid = 10 mm [13/32 in], gas = 20 mm [13/16 in]). Position the edges of the insulation cover and heat-resistant insulation material so as not to leave a gap, and then wrap the exterior perimeter of the pipe joints and middle with tape (field-supplied). ±15° ±15° (4) The length of the straight pipe between indoor units and the twinning pipe Field piping pipe Field-supplied The angle of tilt of the reducer should be within Slope of the twinning pipes are at an angle within ±15° with the ground. ±15° to the horizontal plane Insulation material (field supply) Heat-resistant insulation material (field-supplied) (5) Pipe connection Field piping Field-supplied pipe When connecting the twinning kit to the outdoor unit, note the following: Make sure the pipes from the twinning pipe to the outdoor unit are sloped downwards (towards the twinning pipes). · If the piping on the outdoor unit side (from the twinning pipe) exceeds 2 m [6 ft], ensure a trap (gas pipe only) within 2 m [6 ft]. Make sure the height of the trap is 200 mm [7-7/8 in] or more. If there is no trap, oil can accumulate inside the pipe, causing a shortage of oil and may damage the compressor. <2 m [6 ft] or less> 100 mm [4 in] or more To Indoor unit Downward slope Twinning pipe m(6 [6ft)ft] 22 m Upward slope Twinning kit Twinning kit Insulation Insulationcover cover Insulation cover Insulation cover 200 mm [7-7/8 in] or more ) Twinning pipe * Insulation material Heat-resistant insulation (field supply) material (field-supplied) To Indoor unit Within Less than Twinning pipe 2 m [6 ft] Total pipe length = A+B<10 m [32 ft] unit 3 Outdoor unit 1 Outdoor Outoor unit 1 Outoor unit 2 2 Outdoor Outoor unitunit 3 · If the twinning pipe is installed above the base of the outdoor unit, it should be no more than 200 mm [7-7/8 in]. Lapped space of tape taping Overlap margin of the Tape (field-supplied) Tape (field supply) Twinning 1 Twinning 1 200 mm [7-7/8 in] max Twinning 2 As the insulation cover contracts slightly, conduct Insulation covers shrink. by taping in the fieldcan securely Overlap the tape as shown providing lapped parts asin the left figure so that there shown in the left, so that no gap will be no gap in between the will exist on the insulation cover insulation cover or fieldand field insulation supply insulation installed material. material. Heat-resistant Insulation material insulation (field supply)material (field-supplied) Tape (field (field-supplied) Tape supply) Tape Tape (field-supplied) (field supply) 5. Miscellaneous Notes Twinning 2 To Indoor unit To Indoor unit Less than 200 mm (7 inch) Field-supplied Field pipingpipe <More than 2 m [6 ft] apart> To Indoor unit To Indoor unit Field-supplied Field pipingpipe 3 Secure the field-supplied pipes with a pipe cover and a cable tie in place to keep them from coming in contact with other pipes as necessary. 4 WT05134X02 (2) Accessory piping parts MITSUBISHI ELECTRIC MULTI AIR CONDITIONERS OPTIONAL PARTS Model CMY-Y100VBK2, Y200VBK2, Y300VBK2 Outdoor Twinning Kit Installation Manual CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 • For your safety, thoroughly read the following instructions prior to installation. WARNING Incorrect handling can result in death or serious injury. CAUTION Incorrect handling can result in bodily injury and/or structure damage. Properly install all parts according to the instructions in the Installation Manual. • Improper installation may result in refrigerant gas leakage and equipment damage. • If the wrong twinning pipe or wrong size connecting pipe is used, air conditioning performance will suffer. Do not make any modifications or alterations. Consult your dealer for repair. When installing or relocating the unit, check that no substance other than the specified refrigerant (R410A) enters the refrigerant circuit. After installation, check for a refrigerant leak. • If leaked refrigerant comes in contact with a heat source, such as a fan heater, stove, or electric grill, toxic gases will be generated. PUHY-**Y(S)HM Do not touch the refrigerant pipes and refrigerant circuit components with bare hands during and immediately after operation. • During or immediately after operation, certain parts of the unit such as pipes and compressor may be either very cold or hot, depending on the state of the refrigerant in the unit at the time. To reduce the risk of frostbites and burns, do not touch these parts with bare hands. PUHY-**T(S)HM PUHY-**Y(S)HMU 1. Confirming the Package Contents Twinning kit Twinning kit The following twinning and accessory piping parts are included with the Twinning Kit (CMYY100VBK2, CMY-Y200VBK2, and CMY-Y300VBK2). Verify that all items are present before starting installation. After checking, prepare the twinning kit by connecting the twinning pipes B, C, and D to the twinning pipe A. *Always use the twinning pipes included in the kit when preparing the twinning kit. If the pipes on site do not fit the parts in the kit, use the accessory piping parts listed below. L-shape pipe Dd(After L-shape pipe (Afterthe the twinning) twinning) Insulation Insulationcover cover Twinning TwinningaA PUHY-**T(S)HMU PUHY-**Y(S)HMC b (Before twinning) Pipe c (After the twinning) Pipe Pipe B (Before the the twinning) Pipe C (After the twinning) (1) Twinning pipes (Unit: mm[in]) Label Liquid A Gas D Liquid C Gas B Liquid Second row A (Red) Liquid First row C (Red) Gas Second row D (Red) Gas First row B (Red) Twinning A CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] Pipe B (Before the twinning) OD15.88[5/8]-ID15.88[5/8] L83[3-9/32] OD28.58[1-1/8]-ID28.58[1-1/8] L342[13-15/32] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD31.75[1-1/4]-ID34.93[1-3/8] L337[13-9/32] OD15.88[5/8]-ID19.05[3/4] L85[3-3/8] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD28.58[1-1/8]-ID34.93[1-3/8] L337[13-9/32] OD31.75[1-1/4]-ID38.1[1-1/2] L339[13-3/8] OD15.88[5/8]-ID12.7[1/2] (2) Gas OD34.93[1-3/8]-ID41.28[1-5/8] Liquid OD12.7[1/2]-ID9.52[3/8] OD12.7[1/2]-ID15.88[5/8] (2) OD15.88[5/8]-ID9.52[3/8] OD15.88[5/8]-ID12.7[1/2] Gas OD28.58[1-1/8]-ID22.2[7/8] (3) OD38.1[1-1/2]-ID41.28[1-5/8] OD28.58[1-1/8]-ID19.05[3/4] (2) OD38.1[1-1/2]-ID34.93[1-3/8] Outdoor unit Outdoor unit 1 1 Outdoor unit2 2 Outdoor unit Pipe C (After the twinning) L-shape pipe D (After the twinning) OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD25.4[1]-ID22.2[7/8] OD25.4[1]-ID22.2[7/8] L190[7-1/2] OD15.88[5/8]-ID15.88[5/8] OD15.88[5/8]-ID15.88[5/8] L123[4-27/32] OD28.58[1-1/8]-ID28.58[1-1/8] OD28.58[1-1/8]-ID28.58[1-1/8] L192[7-9/16] OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD15.88[5/8]-ID19.05[3/4] OD15.88[5/8]-ID15.88[5/8] L125[4-15/16] OD25.4[1]-ID28.58[1-1/8] OD25.4[1]-ID28.58[1-1/8] L192[7-9/16] OD28.58[1-1/8]-ID34.93[1-3/8] OD28.58[1-1/8]-ID28.58[1-1/8] L187[7-3/8] Insulation cover C PUHY-**Y(S)HC Instruction Small Large Small A0 P500 P550 P600 P650 P700 P750 P800 P850 P900 EP400 EP450 EP500 EP550 EP600 EP650 HP400 HP500 P500 P550 P600 P650 P700 P750 P800 P850 P900 P144 P168 P192 P216 P240 P144 P168 P192 P216 P240 HP144 HP192 HP400 HP500 P450(-AH) P500 P550 P600 P650 P700 P750 P800 P850 P900 Ee c Aa To Indoor unit unit To Indoor Liquid twinning pipe To Indoor unit unit To Indoor Gas twinning pipe Gas twinning pipe Liquid twinning pipe Ff d Bb 2 Two outdoor units 1 Two outdoor units Package unit name Outdoor unit 1 Component unit name Outdoor unit 2 OutIdoor Twinning Kit Liquid A Indoor unit~Twinning pipe Gas B * See the Installation Manual that came with the outdoor unit for installation instructions. Section Liquid D CAUTION Model OD22.2[7/8]-ID19.05[3/4] (2) 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. • Any presence of foreign substance or air can cause abnormal pressure rise or explosion. • Plastic bags can pose suffocation and choking hazards: keep them out of the reach of children. Tear the plastics bags before disposing of them. OD15.88[5/8]-ID12.7[1/2] OD22.2[7/8]-ID28.58[1-1/8] (1) Two outdoor units Only a dealer or qualified technician should perform installation. Properly dispose of packing materials. OD12.7[1/2]-ID9.52[3/8] (2) Gas 2. Selecting the Correct Size Refrigerant Pipes and Using the Twinning Kit WARNING • If refrigerant leaks and comes in contact with an open flame, toxic gases will be generated. Liquid • Refrigerant pipes other than the ones provided in the kit. • Heat-resistant insulation material (for field-supplied refrigerant pipes) • Insulation cover tape • Thoroughly read the following “Safety Precautions” to ensure proper installation. • Observe the following important safety precautions at all times. • Hazards that can occur from incorrect handling are classified by the symbols below: In the event of a refrigerant leak, thoroughly ventilate the room. Supplied pipe (3) List of field-supplied parts Safety Precautions • Improper installation may result in water leakage, electric shock, or fire. (Unit: mm[in]) Section A0 B0 C0 D0 E0 F0 B0 P250 P300 P350 P350 P350 P400 P450 P450 P450 EP200 P250 EP300 EP300 EP300 P350 HP200 HP250 P250 P300 P350 P350 P350 P400 P450 P450 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 HP72 HP96 HP200 HP250 P250 P250 P300 P350 P350 P350 P400 P400 P450 P450 C0 P250 P250 P250 P300 P350 P350 P350 P400 P450 EP200 EP200 EP200 P250 EP300 EP300 HP200 HP250 P250 P250 P250 P300 P350 P350 P350 P400 P450 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 HP72 HP96 HP200 HP250 P200 P250 P250 P250 P300 P350 P350 P400 P400 P450 Liquid C or E A2 B2 C2 D2 E2 F2 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit (Unit: mm[in]) F0 D0 E0 CMY-Y100VBK2 ø15.88 [5/8] CMY-Y200VBK2 ø19.05 [3/4] ø28.58 [1-1/8] ø34.93 [1-3/8] ø41.28 [1-5/8](*) ø12.7[1/2] PUHY-**YHM CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y200VBK2 CMY-Y100VBK2 PUHY-**THM ø34.93 [1-3/8] ø19.05 [3/4] ø41.28 [1-5/8](*) PUHY-**YHMU ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**THMU CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y200VBK2 ø15.88 [5/8] ø28.58 [1-1/8] ø15.88 [5/8] ø15.88 [5/8] ø28.58 [1-1/8] ø28.58 [1-1/8] PUHY-**YHMC ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**YHC ø34.93 [1-3/8] ø19.05 [3/4] A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8] EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8] P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) Outdoor unit Outdoor unit 1 1 ø41.28 [1-5/8](*) B1 B2 B3 P300 ø12.7 [1/2] ø22.2 [7/8] EP300 ø12.7 [1/2] ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P300 ø12.7 [1/2] ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] HP96 ø9.52 [3/8](*) ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P250 ø9.52 [3/8](*) ø22.2 [7/8] Gas D or F A3 B3 C3 D3 E3 F3 (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) – D1 D2 D3 P400 ø15.88 [5/8] ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8] ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) P120 ø12.7 [1/2] ø22.2 [7/8] P120 ø12.7 [1/2] ø22.2 [7/8] – P400 ø15.88 [5/8] ø28.58 [1-1/8] – P450 ø15.88 [5/8] ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – P300 ø12.7 [1/2] ø22.2 [7/8] P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8] ø28.58 [1-1/8] P450 ø15.88 [5/8] ø28.58 [1-1/8] Outdoor unit Outdoor unit 2 2 Outdoor unit Outdoor unit 3 3 (2) Three outdoor units Large 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. 1 (This sheet) Small Small Large Large cC Gg eE f twinning Liquid 1Liquid twinning pipe pipe 1 D d Hh F Ii Jj twinning pipe 1 Gas 1Gas twinning pipe Aa To Indoor To Indoor unit unit Liquid twinning pipe 2 To Indoor unit Gas twinning pipe 2 Liquid 2 twinning pipe Bb To Indoor unit Gas 2 twinning pipe 1 3 Three outdoor units Package unit name Outdoor unit1 Component unit name Outdoor unit2 Outdoor unit3 Outdoor Twinning Kit Liquid A Indoor unit~Twinning pipe2 Gas B Liquid C Twinning pipe1~Twinning pipe2 Gas D PUHY-**Y(S)HM PUHY-**T(S)HM PUHY-**Y(S)HMU PUHY-**T(S)HMU PUHY-**Y(S)HC A0 P950 P1000 P1050 P1100 P1150 P1200 P1250 EP700 EP750 EP800 EP850 EP900 P950 P1000 P1050 P1100 P1150 P1200 P1250 P264 P288 P312 P336 P360 P264 P288 P312 P336 P360 P850(-AH) P900(-AH) P950 P1000 P1050 P1100 P1150 P1200 P1250 B0 P400 P400 P400 P400 P450 P450 P450 EP300 EP300 EP300 EP300 EP300 P400 P400 P400 P400 P450 P450 P450 P120 P120 P120 P120 P120 P120 P120 P120 P120 P120 P350 P350 P400 P400 P400 P400 P400 P400 P450 C0 P300 P300 P350 P350 P350 P400 P450 EP200 P250 EP300 EP300 EP300 P300 P300 P350 P350 P350 P400 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 P300 P300 P300 P300 P350 P350 P400 P400 P450 4 Three outdoor units A0 B0 C0 D0 E0 F0 G0 H0 I0 D0 P250 P300 P300 P350 P350 P350 P350 EP200 EP200 EP200 P250 EP300 P250 P300 P300 P350 P350 P350 P350 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 P200 P250 P250 P300 P300 P350 P350 P400 P350 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit E0 F0 G0 (Unit: mm[in]) H0 I0 A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8](*) EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] PUHY-**YHM ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) PUHY-**THM PUHY-**YHMU PUHY-**THMU ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 PUHY-**YHC Liqrid E or G or I A2 B2 C2 D2 E2 F2 B1 B2 B3 P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) EP300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) 2 3. Pipe Connection Example Gas F or H or J A3 B3 C3 D3 E3 F3 Connect the pipes between outdoor units, referencing the figures below. <For two outdoor units> (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8] – D1 D2 D3 P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P300 ø12.7 [1/2](*) ø22.2 [7/8](*) P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – P450 – – – ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8](*) ø28.58 [1-1/8] P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – – – Field piping Field-supplied pipe Twinning Twinning kit kit Field piping pipe Field-supplied The length of the straight pipe must Straight pipe mm [19-11/ be 500 mm (19that inch)isor500 longer. 16 in] or more – <For three outdoor units> Field pipingpipe Field-supplied ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] Twinning Twinning kit kit Field piping pipe Field-supplied Twinning kit Twinning kit Straight pipe of that 500 mm The length theisstraight pipe must [19-11/16 in] or more be 500 mm (19 inch) or longer. (3) Slope of twinning pipes Make sure the slope of the twinning pipes are at an angle within ±15° to the horizontal plane. If the slope exceeds the specified angle, the unit may be damaged. The length of the straight pipe must be 500 mm (19 that inch)isor500 longer. Straight pipe mm [19-11/ 16 in] or more Note: Refer to the figure below for the installation Note: See the of following drawing position the twinning pipe.for the fitting position of the twinning pipe. Twinning Reducerpipe Use the pipes supplied in the twinning kit, and make sure the section of the field-supplied pipe that connects to the twinning pipe has at least 500 mm [19-11/16 in] of straight section. (The section of the fieldsupplied pipe that connects to the twinning pipe must have at least 500 mm [19-11/16 in] of straight section.) If the straight section is less than 500 mm [19-11/16 in], it may result in equipment damage. 4. Insulation Cover Installation Install the insulation cover on the twinning kit after brazing the pipes and twinning kit. Insulate all refrigerant pipes. Insulate the liquid and gas pipes separately, and pipes located inside the unit as well as the outside. Use heat-resistant insulation material (Heat resistant: at least 120 °C [248 °F], Thickness: liquid = 10 mm [13/32 in], gas = 20 mm [13/16 in]). Position the edges of the insulation cover and heat-resistant insulation material so as not to leave a gap, and then wrap the exterior perimeter of the pipe joints and middle with tape (field-supplied). ±15° ±15° (4) The length of the straight pipe between indoor units and the twinning pipe Field piping pipe Field-supplied The angle of tilt of the reducer should be within Slope of the twinning pipes are at an angle within ±15° with the ground. ±15° to the horizontal plane Insulation material (field supply) Heat-resistant insulation material (field-supplied) (5) Pipe connection Field piping Field-supplied pipe When connecting the twinning kit to the outdoor unit, note the following: Make sure the pipes from the twinning pipe to the outdoor unit are sloped downwards (towards the twinning pipes). · If the piping on the outdoor unit side (from the twinning pipe) exceeds 2 m [6 ft], ensure a trap (gas pipe only) within 2 m [6 ft]. Make sure the height of the trap is 200 mm [7-7/8 in] or more. If there is no trap, oil can accumulate inside the pipe, causing a shortage of oil and may damage the compressor. <2 m [6 ft] or less> 100 mm [4 in] or more To Indoor unit Downward slope Twinning pipe m(6 [6ft)ft] 22 m Upward slope Twinning kit Twinning kit Insulation Insulationcover cover Insulation cover Insulation cover 200 mm [7-7/8 in] or more ) Twinning pipe * Insulation material Heat-resistant insulation (field supply) material (field-supplied) To Indoor unit Within Less than Twinning pipe 2 m [6 ft] Total pipe length = A+B<10 m [32 ft] unit 3 Outdoor unit 1 Outdoor Outoor unit 1 Outoor unit 2 2 Outdoor Outoor unitunit 3 · If the twinning pipe is installed above the base of the outdoor unit, it should be no more than 200 mm [7-7/8 in]. Lapped space of tape taping Overlap margin of the Tape (field-supplied) Tape (field supply) Twinning 1 Twinning 1 200 mm [7-7/8 in] max Twinning 2 As the insulation cover contracts slightly, conduct Insulation covers shrink. by taping in the fieldcan securely Overlap the tape as shown providing lapped parts asin the left figure so that there shown in the left, so that no gap will be no gap in between the will exist on the insulation cover insulation cover or fieldand field insulation supply insulation installed material. material. Heat-resistant Insulation material insulation (field supply)material (field-supplied) Tape (field (field-supplied) Tape supply) Tape Tape (field-supplied) (field supply) 5. Miscellaneous Notes Twinning 2 To Indoor unit To Indoor unit Less than 200 mm (7 inch) Field-supplied Field pipingpipe <More than 2 m [6 ft] apart> To Indoor unit To Indoor unit Field-supplied Field pipingpipe 3 Secure the field-supplied pipes with a pipe cover and a cable tie in place to keep them from coming in contact with other pipes as necessary. 4 WT05134X02 (2) Accessory piping parts MITSUBISHI ELECTRIC MULTI AIR CONDITIONERS OPTIONAL PARTS Model CMY-Y100VBK2, Y200VBK2, Y300VBK2 Outdoor Twinning Kit Installation Manual CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 • For your safety, thoroughly read the following instructions prior to installation. WARNING Incorrect handling can result in death or serious injury. CAUTION Incorrect handling can result in bodily injury and/or structure damage. Properly install all parts according to the instructions in the Installation Manual. • Improper installation may result in refrigerant gas leakage and equipment damage. • If the wrong twinning pipe or wrong size connecting pipe is used, air conditioning performance will suffer. Do not make any modifications or alterations. Consult your dealer for repair. When installing or relocating the unit, check that no substance other than the specified refrigerant (R410A) enters the refrigerant circuit. After installation, check for a refrigerant leak. • If leaked refrigerant comes in contact with a heat source, such as a fan heater, stove, or electric grill, toxic gases will be generated. PUHY-**Y(S)HM Do not touch the refrigerant pipes and refrigerant circuit components with bare hands during and immediately after operation. • During or immediately after operation, certain parts of the unit such as pipes and compressor may be either very cold or hot, depending on the state of the refrigerant in the unit at the time. To reduce the risk of frostbites and burns, do not touch these parts with bare hands. PUHY-**T(S)HM PUHY-**Y(S)HMU 1. Confirming the Package Contents Twinning kit Twinning kit The following twinning and accessory piping parts are included with the Twinning Kit (CMYY100VBK2, CMY-Y200VBK2, and CMY-Y300VBK2). Verify that all items are present before starting installation. After checking, prepare the twinning kit by connecting the twinning pipes B, C, and D to the twinning pipe A. *Always use the twinning pipes included in the kit when preparing the twinning kit. If the pipes on site do not fit the parts in the kit, use the accessory piping parts listed below. L-shape pipe Dd(After L-shape pipe (Afterthe the twinning) twinning) Insulation Insulationcover cover Twinning TwinningaA PUHY-**T(S)HMU PUHY-**Y(S)HMC b (Before twinning) Pipe c (After the twinning) Pipe Pipe B (Before the the twinning) Pipe C (After the twinning) (1) Twinning pipes (Unit: mm[in]) Label Liquid A Gas D Liquid C Gas B Liquid Second row A (Red) Liquid First row C (Red) Gas Second row D (Red) Gas First row B (Red) Twinning A CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] Pipe B (Before the twinning) OD15.88[5/8]-ID15.88[5/8] L83[3-9/32] OD28.58[1-1/8]-ID28.58[1-1/8] L342[13-15/32] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD31.75[1-1/4]-ID34.93[1-3/8] L337[13-9/32] OD15.88[5/8]-ID19.05[3/4] L85[3-3/8] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD28.58[1-1/8]-ID34.93[1-3/8] L337[13-9/32] OD31.75[1-1/4]-ID38.1[1-1/2] L339[13-3/8] OD15.88[5/8]-ID12.7[1/2] (2) Gas OD34.93[1-3/8]-ID41.28[1-5/8] Liquid OD12.7[1/2]-ID9.52[3/8] OD12.7[1/2]-ID15.88[5/8] (2) OD15.88[5/8]-ID9.52[3/8] OD15.88[5/8]-ID12.7[1/2] Gas OD28.58[1-1/8]-ID22.2[7/8] (3) OD38.1[1-1/2]-ID41.28[1-5/8] OD28.58[1-1/8]-ID19.05[3/4] (2) OD38.1[1-1/2]-ID34.93[1-3/8] Outdoor unit Outdoor unit 1 1 Outdoor unit2 2 Outdoor unit Pipe C (After the twinning) L-shape pipe D (After the twinning) OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD25.4[1]-ID22.2[7/8] OD25.4[1]-ID22.2[7/8] L190[7-1/2] OD15.88[5/8]-ID15.88[5/8] OD15.88[5/8]-ID15.88[5/8] L123[4-27/32] OD28.58[1-1/8]-ID28.58[1-1/8] OD28.58[1-1/8]-ID28.58[1-1/8] L192[7-9/16] OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD15.88[5/8]-ID19.05[3/4] OD15.88[5/8]-ID15.88[5/8] L125[4-15/16] OD25.4[1]-ID28.58[1-1/8] OD25.4[1]-ID28.58[1-1/8] L192[7-9/16] OD28.58[1-1/8]-ID34.93[1-3/8] OD28.58[1-1/8]-ID28.58[1-1/8] L187[7-3/8] Insulation cover C PUHY-**Y(S)HC Instruction Small Large Small A0 P500 P550 P600 P650 P700 P750 P800 P850 P900 EP400 EP450 EP500 EP550 EP600 EP650 HP400 HP500 P500 P550 P600 P650 P700 P750 P800 P850 P900 P144 P168 P192 P216 P240 P144 P168 P192 P216 P240 HP144 HP192 HP400 HP500 P450(-AH) P500 P550 P600 P650 P700 P750 P800 P850 P900 Ee c Aa To Indoor unit unit To Indoor Liquid twinning pipe To Indoor unit unit To Indoor Gas twinning pipe Gas twinning pipe Liquid twinning pipe Ff d Bb 2 Two outdoor units 1 Two outdoor units Package unit name Outdoor unit 1 Component unit name Outdoor unit 2 OutIdoor Twinning Kit Liquid A Indoor unit~Twinning pipe Gas B * See the Installation Manual that came with the outdoor unit for installation instructions. Section Liquid D CAUTION Model OD22.2[7/8]-ID19.05[3/4] (2) 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. • Any presence of foreign substance or air can cause abnormal pressure rise or explosion. • Plastic bags can pose suffocation and choking hazards: keep them out of the reach of children. Tear the plastics bags before disposing of them. OD15.88[5/8]-ID12.7[1/2] OD22.2[7/8]-ID28.58[1-1/8] (1) Two outdoor units Only a dealer or qualified technician should perform installation. Properly dispose of packing materials. OD12.7[1/2]-ID9.52[3/8] (2) Gas 2. Selecting the Correct Size Refrigerant Pipes and Using the Twinning Kit WARNING • If refrigerant leaks and comes in contact with an open flame, toxic gases will be generated. Liquid • Refrigerant pipes other than the ones provided in the kit. • Heat-resistant insulation material (for field-supplied refrigerant pipes) • Insulation cover tape • Thoroughly read the following “Safety Precautions” to ensure proper installation. • Observe the following important safety precautions at all times. • Hazards that can occur from incorrect handling are classified by the symbols below: In the event of a refrigerant leak, thoroughly ventilate the room. Supplied pipe (3) List of field-supplied parts Safety Precautions • Improper installation may result in water leakage, electric shock, or fire. (Unit: mm[in]) Section A0 B0 C0 D0 E0 F0 B0 P250 P300 P350 P350 P350 P400 P450 P450 P450 EP200 P250 EP300 EP300 EP300 P350 HP200 HP250 P250 P300 P350 P350 P350 P400 P450 P450 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 HP72 HP96 HP200 HP250 P250 P250 P300 P350 P350 P350 P400 P400 P450 P450 C0 P250 P250 P250 P300 P350 P350 P350 P400 P450 EP200 EP200 EP200 P250 EP300 EP300 HP200 HP250 P250 P250 P250 P300 P350 P350 P350 P400 P450 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 HP72 HP96 HP200 HP250 P200 P250 P250 P250 P300 P350 P350 P400 P400 P450 Liquid C or E A2 B2 C2 D2 E2 F2 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit (Unit: mm[in]) F0 D0 E0 CMY-Y100VBK2 ø15.88 [5/8] CMY-Y200VBK2 ø19.05 [3/4] ø28.58 [1-1/8] ø34.93 [1-3/8] ø41.28 [1-5/8](*) ø12.7[1/2] PUHY-**YHM CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y200VBK2 CMY-Y100VBK2 PUHY-**THM ø34.93 [1-3/8] ø19.05 [3/4] ø41.28 [1-5/8](*) PUHY-**YHMU ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**THMU CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y200VBK2 ø15.88 [5/8] ø28.58 [1-1/8] ø15.88 [5/8] ø15.88 [5/8] ø28.58 [1-1/8] ø28.58 [1-1/8] PUHY-**YHMC ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**YHC ø34.93 [1-3/8] ø19.05 [3/4] A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8] EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8] P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) Outdoor unit Outdoor unit 1 1 ø41.28 [1-5/8](*) B1 B2 B3 P300 ø12.7 [1/2] ø22.2 [7/8] EP300 ø12.7 [1/2] ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P300 ø12.7 [1/2] ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] HP96 ø9.52 [3/8](*) ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P250 ø9.52 [3/8](*) ø22.2 [7/8] Gas D or F A3 B3 C3 D3 E3 F3 (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) – D1 D2 D3 P400 ø15.88 [5/8] ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8] ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) P120 ø12.7 [1/2] ø22.2 [7/8] P120 ø12.7 [1/2] ø22.2 [7/8] – P400 ø15.88 [5/8] ø28.58 [1-1/8] – P450 ø15.88 [5/8] ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – P300 ø12.7 [1/2] ø22.2 [7/8] P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8] ø28.58 [1-1/8] P450 ø15.88 [5/8] ø28.58 [1-1/8] Outdoor unit Outdoor unit 2 2 Outdoor unit Outdoor unit 3 3 (2) Three outdoor units Large 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. 1 (This sheet) Small Small Large Large cC Gg eE f twinning Liquid 1Liquid twinning pipe pipe 1 D d Hh F Ii Jj twinning pipe 1 Gas 1Gas twinning pipe Aa To Indoor To Indoor unit unit Liquid twinning pipe 2 To Indoor unit Gas twinning pipe 2 Liquid 2 twinning pipe Bb To Indoor unit Gas 2 twinning pipe 1 3 Three outdoor units Package unit name Outdoor unit1 Component unit name Outdoor unit2 Outdoor unit3 Outdoor Twinning Kit Liquid A Indoor unit~Twinning pipe2 Gas B Liquid C Twinning pipe1~Twinning pipe2 Gas D PUHY-**Y(S)HM PUHY-**T(S)HM PUHY-**Y(S)HMU PUHY-**T(S)HMU PUHY-**Y(S)HC A0 P950 P1000 P1050 P1100 P1150 P1200 P1250 EP700 EP750 EP800 EP850 EP900 P950 P1000 P1050 P1100 P1150 P1200 P1250 P264 P288 P312 P336 P360 P264 P288 P312 P336 P360 P850(-AH) P900(-AH) P950 P1000 P1050 P1100 P1150 P1200 P1250 B0 P400 P400 P400 P400 P450 P450 P450 EP300 EP300 EP300 EP300 EP300 P400 P400 P400 P400 P450 P450 P450 P120 P120 P120 P120 P120 P120 P120 P120 P120 P120 P350 P350 P400 P400 P400 P400 P400 P400 P450 C0 P300 P300 P350 P350 P350 P400 P450 EP200 P250 EP300 EP300 EP300 P300 P300 P350 P350 P350 P400 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 P300 P300 P300 P300 P350 P350 P400 P400 P450 4 Three outdoor units A0 B0 C0 D0 E0 F0 G0 H0 I0 D0 P250 P300 P300 P350 P350 P350 P350 EP200 EP200 EP200 P250 EP300 P250 P300 P300 P350 P350 P350 P350 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 P200 P250 P250 P300 P300 P350 P350 P400 P350 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit E0 F0 G0 (Unit: mm[in]) H0 I0 A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8](*) EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] PUHY-**YHM ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) PUHY-**THM PUHY-**YHMU PUHY-**THMU ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 PUHY-**YHC Liqrid E or G or I A2 B2 C2 D2 E2 F2 B1 B2 B3 P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) EP300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) 2 3. Pipe Connection Example Gas F or H or J A3 B3 C3 D3 E3 F3 Connect the pipes between outdoor units, referencing the figures below. <For two outdoor units> (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8] – D1 D2 D3 P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P300 ø12.7 [1/2](*) ø22.2 [7/8](*) P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – P450 – – – ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8](*) ø28.58 [1-1/8] P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – – – Field piping Field-supplied pipe Twinning Twinning kit kit Field piping pipe Field-supplied The length of the straight pipe must Straight pipe mm [19-11/ be 500 mm (19that inch)isor500 longer. 16 in] or more – <For three outdoor units> Field pipingpipe Field-supplied ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] Twinning Twinning kit kit Field piping pipe Field-supplied Twinning kit Twinning kit Straight pipe of that 500 mm The length theisstraight pipe must [19-11/16 in] or more be 500 mm (19 inch) or longer. (3) Slope of twinning pipes Make sure the slope of the twinning pipes are at an angle within ±15° to the horizontal plane. If the slope exceeds the specified angle, the unit may be damaged. The length of the straight pipe must be 500 mm (19 that inch)isor500 longer. Straight pipe mm [19-11/ 16 in] or more Note: Refer to the figure below for the installation Note: See the of following drawing position the twinning pipe.for the fitting position of the twinning pipe. Twinning Reducerpipe Use the pipes supplied in the twinning kit, and make sure the section of the field-supplied pipe that connects to the twinning pipe has at least 500 mm [19-11/16 in] of straight section. (The section of the fieldsupplied pipe that connects to the twinning pipe must have at least 500 mm [19-11/16 in] of straight section.) If the straight section is less than 500 mm [19-11/16 in], it may result in equipment damage. 4. Insulation Cover Installation Install the insulation cover on the twinning kit after brazing the pipes and twinning kit. Insulate all refrigerant pipes. Insulate the liquid and gas pipes separately, and pipes located inside the unit as well as the outside. Use heat-resistant insulation material (Heat resistant: at least 120 °C [248 °F], Thickness: liquid = 10 mm [13/32 in], gas = 20 mm [13/16 in]). Position the edges of the insulation cover and heat-resistant insulation material so as not to leave a gap, and then wrap the exterior perimeter of the pipe joints and middle with tape (field-supplied). ±15° ±15° (4) The length of the straight pipe between indoor units and the twinning pipe Field piping pipe Field-supplied The angle of tilt of the reducer should be within Slope of the twinning pipes are at an angle within ±15° with the ground. ±15° to the horizontal plane Insulation material (field supply) Heat-resistant insulation material (field-supplied) (5) Pipe connection Field piping Field-supplied pipe When connecting the twinning kit to the outdoor unit, note the following: Make sure the pipes from the twinning pipe to the outdoor unit are sloped downwards (towards the twinning pipes). · If the piping on the outdoor unit side (from the twinning pipe) exceeds 2 m [6 ft], ensure a trap (gas pipe only) within 2 m [6 ft]. Make sure the height of the trap is 200 mm [7-7/8 in] or more. If there is no trap, oil can accumulate inside the pipe, causing a shortage of oil and may damage the compressor. <2 m [6 ft] or less> 100 mm [4 in] or more To Indoor unit Downward slope Twinning pipe m(6 [6ft)ft] 22 m Upward slope Twinning kit Twinning kit Insulation Insulationcover cover Insulation cover Insulation cover 200 mm [7-7/8 in] or more ) Twinning pipe * Insulation material Heat-resistant insulation (field supply) material (field-supplied) To Indoor unit Within Less than Twinning pipe 2 m [6 ft] Total pipe length = A+B<10 m [32 ft] unit 3 Outdoor unit 1 Outdoor Outoor unit 1 Outoor unit 2 2 Outdoor Outoor unitunit 3 · If the twinning pipe is installed above the base of the outdoor unit, it should be no more than 200 mm [7-7/8 in]. Lapped space of tape taping Overlap margin of the Tape (field-supplied) Tape (field supply) Twinning 1 Twinning 1 200 mm [7-7/8 in] max Twinning 2 As the insulation cover contracts slightly, conduct Insulation covers shrink. by taping in the fieldcan securely Overlap the tape as shown providing lapped parts asin the left figure so that there shown in the left, so that no gap will be no gap in between the will exist on the insulation cover insulation cover or fieldand field insulation supply insulation installed material. material. Heat-resistant Insulation material insulation (field supply)material (field-supplied) Tape (field (field-supplied) Tape supply) Tape Tape (field-supplied) (field supply) 5. Miscellaneous Notes Twinning 2 To Indoor unit To Indoor unit Less than 200 mm (7 inch) Field-supplied Field pipingpipe <More than 2 m [6 ft] apart> To Indoor unit To Indoor unit Field-supplied Field pipingpipe 3 Secure the field-supplied pipes with a pipe cover and a cable tie in place to keep them from coming in contact with other pipes as necessary. 4 WT05134X02 (2) Accessory piping parts MITSUBISHI ELECTRIC MULTI AIR CONDITIONERS OPTIONAL PARTS Model CMY-Y100VBK2, Y200VBK2, Y300VBK2 Outdoor Twinning Kit Installation Manual CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 • For your safety, thoroughly read the following instructions prior to installation. WARNING Incorrect handling can result in death or serious injury. CAUTION Incorrect handling can result in bodily injury and/or structure damage. Properly install all parts according to the instructions in the Installation Manual. • Improper installation may result in refrigerant gas leakage and equipment damage. • If the wrong twinning pipe or wrong size connecting pipe is used, air conditioning performance will suffer. Do not make any modifications or alterations. Consult your dealer for repair. When installing or relocating the unit, check that no substance other than the specified refrigerant (R410A) enters the refrigerant circuit. After installation, check for a refrigerant leak. • If leaked refrigerant comes in contact with a heat source, such as a fan heater, stove, or electric grill, toxic gases will be generated. PUHY-**Y(S)HM Do not touch the refrigerant pipes and refrigerant circuit components with bare hands during and immediately after operation. • During or immediately after operation, certain parts of the unit such as pipes and compressor may be either very cold or hot, depending on the state of the refrigerant in the unit at the time. To reduce the risk of frostbites and burns, do not touch these parts with bare hands. PUHY-**T(S)HM PUHY-**Y(S)HMU 1. Confirming the Package Contents Twinning kit Twinning kit The following twinning and accessory piping parts are included with the Twinning Kit (CMYY100VBK2, CMY-Y200VBK2, and CMY-Y300VBK2). Verify that all items are present before starting installation. After checking, prepare the twinning kit by connecting the twinning pipes B, C, and D to the twinning pipe A. *Always use the twinning pipes included in the kit when preparing the twinning kit. If the pipes on site do not fit the parts in the kit, use the accessory piping parts listed below. L-shape pipe Dd(After L-shape pipe (Afterthe the twinning) twinning) Insulation Insulationcover cover Twinning TwinningaA PUHY-**T(S)HMU PUHY-**Y(S)HMC b (Before twinning) Pipe c (After the twinning) Pipe Pipe B (Before the the twinning) Pipe C (After the twinning) (1) Twinning pipes (Unit: mm[in]) Label Liquid A Gas D Liquid C Gas B Liquid Second row A (Red) Liquid First row C (Red) Gas Second row D (Red) Gas First row B (Red) Twinning A CMY-Y100VBK2 CMY-Y200VBK2 CMY-Y300VBK2 ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] ID15.88[5/8]×ID12.7[1/2]× ID12.7[1/2] ID19.05[3/4]×ID15.88[5/8]× ID15.88[5/8] ID28.58[1-1/8]×ID25.4[1]× ID25.4[1] ID31.75[1-1/4]×ID28.58 [1-1/8]×ID28.58[1-1/8] Pipe B (Before the twinning) OD15.88[5/8]-ID15.88[5/8] L83[3-9/32] OD28.58[1-1/8]-ID28.58[1-1/8] L342[13-15/32] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD31.75[1-1/4]-ID34.93[1-3/8] L337[13-9/32] OD15.88[5/8]-ID19.05[3/4] L85[3-3/8] OD19.05[3/4]-ID19.05[3/4] L85[3-3/8] OD28.58[1-1/8]-ID34.93[1-3/8] L337[13-9/32] OD31.75[1-1/4]-ID38.1[1-1/2] L339[13-3/8] OD15.88[5/8]-ID12.7[1/2] (2) Gas OD34.93[1-3/8]-ID41.28[1-5/8] Liquid OD12.7[1/2]-ID9.52[3/8] OD12.7[1/2]-ID15.88[5/8] (2) OD15.88[5/8]-ID9.52[3/8] OD15.88[5/8]-ID12.7[1/2] Gas OD28.58[1-1/8]-ID22.2[7/8] (3) OD38.1[1-1/2]-ID41.28[1-5/8] OD28.58[1-1/8]-ID19.05[3/4] (2) OD38.1[1-1/2]-ID34.93[1-3/8] Outdoor unit Outdoor unit 1 1 Outdoor unit2 2 Outdoor unit Pipe C (After the twinning) L-shape pipe D (After the twinning) OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD25.4[1]-ID22.2[7/8] OD25.4[1]-ID22.2[7/8] L190[7-1/2] OD15.88[5/8]-ID15.88[5/8] OD15.88[5/8]-ID15.88[5/8] L123[4-27/32] OD28.58[1-1/8]-ID28.58[1-1/8] OD28.58[1-1/8]-ID28.58[1-1/8] L192[7-9/16] OD12.7[1/2]-ID12.7[1/2] OD12.7[1/2]-ID12.7[1/2] L128[5-1/16] OD15.88[5/8]-ID19.05[3/4] OD15.88[5/8]-ID15.88[5/8] L125[4-15/16] OD25.4[1]-ID28.58[1-1/8] OD25.4[1]-ID28.58[1-1/8] L192[7-9/16] OD28.58[1-1/8]-ID34.93[1-3/8] OD28.58[1-1/8]-ID28.58[1-1/8] L187[7-3/8] Insulation cover C PUHY-**Y(S)HC Instruction Small Large Small A0 P500 P550 P600 P650 P700 P750 P800 P850 P900 EP400 EP450 EP500 EP550 EP600 EP650 HP400 HP500 P500 P550 P600 P650 P700 P750 P800 P850 P900 P144 P168 P192 P216 P240 P144 P168 P192 P216 P240 HP144 HP192 HP400 HP500 P450(-AH) P500 P550 P600 P650 P700 P750 P800 P850 P900 Ee c Aa To Indoor unit unit To Indoor Liquid twinning pipe To Indoor unit unit To Indoor Gas twinning pipe Gas twinning pipe Liquid twinning pipe Ff d Bb 2 Two outdoor units 1 Two outdoor units Package unit name Outdoor unit 1 Component unit name Outdoor unit 2 OutIdoor Twinning Kit Liquid A Indoor unit~Twinning pipe Gas B * See the Installation Manual that came with the outdoor unit for installation instructions. Section Liquid D CAUTION Model OD22.2[7/8]-ID19.05[3/4] (2) 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. • Any presence of foreign substance or air can cause abnormal pressure rise or explosion. • Plastic bags can pose suffocation and choking hazards: keep them out of the reach of children. Tear the plastics bags before disposing of them. OD15.88[5/8]-ID12.7[1/2] OD22.2[7/8]-ID28.58[1-1/8] (1) Two outdoor units Only a dealer or qualified technician should perform installation. Properly dispose of packing materials. OD12.7[1/2]-ID9.52[3/8] (2) Gas 2. Selecting the Correct Size Refrigerant Pipes and Using the Twinning Kit WARNING • If refrigerant leaks and comes in contact with an open flame, toxic gases will be generated. Liquid • Refrigerant pipes other than the ones provided in the kit. • Heat-resistant insulation material (for field-supplied refrigerant pipes) • Insulation cover tape • Thoroughly read the following “Safety Precautions” to ensure proper installation. • Observe the following important safety precautions at all times. • Hazards that can occur from incorrect handling are classified by the symbols below: In the event of a refrigerant leak, thoroughly ventilate the room. Supplied pipe (3) List of field-supplied parts Safety Precautions • Improper installation may result in water leakage, electric shock, or fire. (Unit: mm[in]) Section A0 B0 C0 D0 E0 F0 B0 P250 P300 P350 P350 P350 P400 P450 P450 P450 EP200 P250 EP300 EP300 EP300 P350 HP200 HP250 P250 P300 P350 P350 P350 P400 P450 P450 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 HP72 HP96 HP200 HP250 P250 P250 P300 P350 P350 P350 P400 P400 P450 P450 C0 P250 P250 P250 P300 P350 P350 P350 P400 P450 EP200 EP200 EP200 P250 EP300 EP300 HP200 HP250 P250 P250 P250 P300 P350 P350 P350 P400 P450 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 HP72 HP96 HP200 HP250 P200 P250 P250 P250 P300 P350 P350 P400 P400 P450 Liquid C or E A2 B2 C2 D2 E2 F2 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit (Unit: mm[in]) F0 D0 E0 CMY-Y100VBK2 ø15.88 [5/8] CMY-Y200VBK2 ø19.05 [3/4] ø28.58 [1-1/8] ø34.93 [1-3/8] ø41.28 [1-5/8](*) ø12.7[1/2] PUHY-**YHM CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y100VBK2 ø15.88 [5/8] ø28.58 [1-1/8] CMY-Y200VBK2 CMY-Y100VBK2 PUHY-**THM ø34.93 [1-3/8] ø19.05 [3/4] ø41.28 [1-5/8](*) PUHY-**YHMU ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**THMU CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y100VBK2 CMY-Y200VBK2 ø15.88 [5/8] ø28.58 [1-1/8] ø15.88 [5/8] ø15.88 [5/8] ø28.58 [1-1/8] ø28.58 [1-1/8] PUHY-**YHMC ø28.58 [1-1/8] ø15.88 [5/8] PUHY-**YHC ø34.93 [1-3/8] ø19.05 [3/4] A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8] EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8] P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP72 ø9.52 [3/8](*) ø19.05 [3/4](*) HP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) Outdoor unit Outdoor unit 1 1 ø41.28 [1-5/8](*) B1 B2 B3 P300 ø12.7 [1/2] ø22.2 [7/8] EP300 ø12.7 [1/2] ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P300 ø12.7 [1/2] ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] P96 ø9.52 [3/8](*) ø22.2 [7/8] HP96 ø9.52 [3/8](*) ø22.2 [7/8] HP250 ø9.52 [3/8](*) ø22.2 [7/8] P250 ø9.52 [3/8](*) ø22.2 [7/8] Gas D or F A3 B3 C3 D3 E3 F3 (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) – D1 D2 D3 P400 ø15.88 [5/8] ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8] ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8](*) P120 ø12.7 [1/2] ø22.2 [7/8] P120 ø12.7 [1/2] ø22.2 [7/8] – P400 ø15.88 [5/8] ø28.58 [1-1/8] – P450 ø15.88 [5/8] ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – P300 ø12.7 [1/2] ø22.2 [7/8] P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8] ø28.58 [1-1/8] P450 ø15.88 [5/8] ø28.58 [1-1/8] Outdoor unit Outdoor unit 2 2 Outdoor unit Outdoor unit 3 3 (2) Three outdoor units Large 1 Field-supply the pipes to be connected to the kit. 2 Choose the correct size pipe using the table below. Connect the field-supplied pipe to the twinning kit for the sizes in the table that are marked with an asterisk (*). 3 If the pipe was cut with a pipe cutter, remove the burrs and eliminate foreign materials before connecting. 1 (This sheet) Small Small Large Large cC Gg eE f twinning Liquid 1Liquid twinning pipe pipe 1 D d Hh F Ii Jj twinning pipe 1 Gas 1Gas twinning pipe Aa To Indoor To Indoor unit unit Liquid twinning pipe 2 To Indoor unit Gas twinning pipe 2 Liquid 2 twinning pipe Bb To Indoor unit Gas 2 twinning pipe 1 3 Three outdoor units Package unit name Outdoor unit1 Component unit name Outdoor unit2 Outdoor unit3 Outdoor Twinning Kit Liquid A Indoor unit~Twinning pipe2 Gas B Liquid C Twinning pipe1~Twinning pipe2 Gas D PUHY-**Y(S)HM PUHY-**T(S)HM PUHY-**Y(S)HMU PUHY-**T(S)HMU PUHY-**Y(S)HC A0 P950 P1000 P1050 P1100 P1150 P1200 P1250 EP700 EP750 EP800 EP850 EP900 P950 P1000 P1050 P1100 P1150 P1200 P1250 P264 P288 P312 P336 P360 P264 P288 P312 P336 P360 P850(-AH) P900(-AH) P950 P1000 P1050 P1100 P1150 P1200 P1250 B0 P400 P400 P400 P400 P450 P450 P450 EP300 EP300 EP300 EP300 EP300 P400 P400 P400 P400 P450 P450 P450 P120 P120 P120 P120 P120 P120 P120 P120 P120 P120 P350 P350 P400 P400 P400 P400 P400 P400 P450 C0 P300 P300 P350 P350 P350 P400 P450 EP200 P250 EP300 EP300 EP300 P300 P300 P350 P350 P350 P400 P450 P72 P96 P120 P120 P120 P72 P96 P120 P120 P120 P300 P300 P300 P300 P350 P350 P400 P400 P450 4 Three outdoor units A0 B0 C0 D0 E0 F0 G0 H0 I0 D0 P250 P300 P300 P350 P350 P350 P350 EP200 EP200 EP200 P250 EP300 P250 P300 P300 P350 P350 P350 P350 P72 P72 P72 P96 P120 P72 P72 P72 P96 P120 P200 P250 P250 P300 P300 P350 P350 P400 P350 Unit model A1 B1 C1 D1 E1 F1 Twinning pipe~Outdoor unit E0 F0 G0 (Unit: mm[in]) H0 I0 A1 A2 A3 P250 ø9.52 [3/8](*) ø22.2 [7/8](*) EP200 ø9.52 [3/8](*) ø19.05 [3/4](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P72 ø9.52 [3/8](*) ø19.05 [3/4](*) P200 ø9.52 [3/8](*) ø19.05 [3/4](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] PUHY-**YHM ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) PUHY-**THM PUHY-**YHMU PUHY-**THMU ø34.93 ø19.05 [1-3/8](*) ø19.05 ø34.93 CMY-Y300VBK2 [3/4] [3/4] [1-3/8] ø41.28 [1-5/8](*) CMY-Y300VBK2 PUHY-**YHC Liqrid E or G or I A2 B2 C2 D2 E2 F2 B1 B2 B3 P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) EP300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P300 ø12.7 [1/2](*) ø 22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P96 ø9.52 [3/8](*) ø22.2 [7/8](*) P250 ø9.52 [3/8](*) ø22.2 [7/8](*) 2 3. Pipe Connection Example Gas F or H or J A3 B3 C3 D3 E3 F3 Connect the pipes between outdoor units, referencing the figures below. <For two outdoor units> (Unit: mm[in]) C1 C2 C3 P350 ø12.7 [1/2](*) ø28.58 [1-1/8] – D1 D2 D3 P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – E1 E2 E3 P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – F1 F2 F3 – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P120 ø12.7 [1/2](*) ø22.2 [7/8](*) P300 ø12.7 [1/2](*) ø22.2 [7/8](*) P400 ø15.88 [5/8](*) ø28.58 [1-1/8] – P450 – – – ø28.58 [1-1/8] – – – – – – – – – – – – – – – – – P350 ø12.7 [1/2](*) ø28.58 [1-1/8] P400 ø15.88 [5/8](*) ø28.58 [1-1/8] P450 ø15.88 [5/8](*) ø28.58 [1-1/8] – – – Field piping Field-supplied pipe Twinning Twinning kit kit Field piping pipe Field-supplied The length of the straight pipe must Straight pipe mm [19-11/ be 500 mm (19that inch)isor500 longer. 16 in] or more – <For three outdoor units> Field pipingpipe Field-supplied ø19.05 ø41.28 ø19.05 ø34.93 [3/4] [1-5/8](*) [3/4] [1-3/8] Twinning Twinning kit kit Field piping pipe Field-supplied Twinning kit Twinning kit Straight pipe of that 500 mm The length theisstraight pipe must [19-11/16 in] or more be 500 mm (19 inch) or longer. (3) Slope of twinning pipes Make sure the slope of the twinning pipes are at an angle within ±15° to the horizontal plane. If the slope exceeds the specified angle, the unit may be damaged. The length of the straight pipe must be 500 mm (19 that inch)isor500 longer. Straight pipe mm [19-11/ 16 in] or more Note: Refer to the figure below for the installation Note: See the of following drawing position the twinning pipe.for the fitting position of the twinning pipe. Twinning Reducerpipe Use the pipes supplied in the twinning kit, and make sure the section of the field-supplied pipe that connects to the twinning pipe has at least 500 mm [19-11/16 in] of straight section. (The section of the fieldsupplied pipe that connects to the twinning pipe must have at least 500 mm [19-11/16 in] of straight section.) If the straight section is less than 500 mm [19-11/16 in], it may result in equipment damage. 4. Insulation Cover Installation Install the insulation cover on the twinning kit after brazing the pipes and twinning kit. Insulate all refrigerant pipes. Insulate the liquid and gas pipes separately, and pipes located inside the unit as well as the outside. Use heat-resistant insulation material (Heat resistant: at least 120 °C [248 °F], Thickness: liquid = 10 mm [13/32 in], gas = 20 mm [13/16 in]). Position the edges of the insulation cover and heat-resistant insulation material so as not to leave a gap, and then wrap the exterior perimeter of the pipe joints and middle with tape (field-supplied). ±15° ±15° (4) The length of the straight pipe between indoor units and the twinning pipe Field piping pipe Field-supplied The angle of tilt of the reducer should be within Slope of the twinning pipes are at an angle within ±15° with the ground. ±15° to the horizontal plane Insulation material (field supply) Heat-resistant insulation material (field-supplied) (5) Pipe connection Field piping Field-supplied pipe When connecting the twinning kit to the outdoor unit, note the following: Make sure the pipes from the twinning pipe to the outdoor unit are sloped downwards (towards the twinning pipes). · If the piping on the outdoor unit side (from the twinning pipe) exceeds 2 m [6 ft], ensure a trap (gas pipe only) within 2 m [6 ft]. Make sure the height of the trap is 200 mm [7-7/8 in] or more. If there is no trap, oil can accumulate inside the pipe, causing a shortage of oil and may damage the compressor. <2 m [6 ft] or less> 100 mm [4 in] or more To Indoor unit Downward slope Twinning pipe m(6 [6ft)ft] 22 m Upward slope Twinning kit Twinning kit Insulation Insulationcover cover Insulation cover Insulation cover 200 mm [7-7/8 in] or more ) Twinning pipe * Insulation material Heat-resistant insulation (field supply) material (field-supplied) To Indoor unit Within Less than Twinning pipe 2 m [6 ft] Total pipe length = A+B<10 m [32 ft] unit 3 Outdoor unit 1 Outdoor Outoor unit 1 Outoor unit 2 2 Outdoor Outoor unitunit 3 · If the twinning pipe is installed above the base of the outdoor unit, it should be no more than 200 mm [7-7/8 in]. Lapped space of tape taping Overlap margin of the Tape (field-supplied) Tape (field supply) Twinning 1 Twinning 1 200 mm [7-7/8 in] max Twinning 2 As the insulation cover contracts slightly, conduct Insulation covers shrink. by taping in the fieldcan securely Overlap the tape as shown providing lapped parts asin the left figure so that there shown in the left, so that no gap will be no gap in between the will exist on the insulation cover insulation cover or fieldand field insulation supply insulation installed material. material. Heat-resistant Insulation material insulation (field supply)material (field-supplied) Tape (field (field-supplied) Tape supply) Tape Tape (field-supplied) (field supply) 5. Miscellaneous Notes Twinning 2 To Indoor unit To Indoor unit Less than 200 mm (7 inch) Field-supplied Field pipingpipe <More than 2 m [6 ft] apart> To Indoor unit To Indoor unit Field-supplied Field pipingpipe 3 Secure the field-supplied pipes with a pipe cover and a cable tie in place to keep them from coming in contact with other pipes as necessary. 4
Similar documents
Model: 16-TON PUHY-P192YSJMU-A-BS
smaller capacity units can be piped together to form a single, large-capacity two-pipe system • Required Twinning Kit allows for easy field piping connection • Selectable fan static, 0.12 or 0.24"W...
More information