Model: PUHY-P216TSKMU-A
Transcription
Model: PUHY-P216TSKMU-A
Model: PUHY-P216TSKMU-A (Consists of One PUHY-P120TKMU-A, One PUHY-P96TKMU-A, and One CMY-Y100CBK3 Twinning Kit) Job Name: Location: Engineer Name: Contractor: System No.: Date: OUTDOOR VRF HEAT PUMP SYSTEM FEATURES • 3-phase, 208/230V • Modular variable refrigerant flow (VRF) systems; smaller capacity units can be piped together to form a single, large-capacity two-pipe system • Required Twinning Kit allows for easy field piping connection • Selectable fan static, 0.12 or 0.24"WG external static pressure; factory set to 0"WG • Connects to CITY MULTI indoor units; controlled via CITY MULTI Controls Network (CMCN) • External finish: Pre-coated Galvanized-steel Sheets • Operating Temperature Range Cooling (Outdoor): 23° ~ 115°F (-5° ~ +46°C) DB Heating (Outdoor): -4° ~ +60°F (-20° ~ +16°C) WB PUHY-P120TKMU-A PUHY-P96TKMU-A OPTIONAL PARTS □ Twinning Kit*.…………………………………...…….CMY-Y100CBK3 □ T-Branch Joint (≤ 72,000 Btu/h)………………..........CMY-Y102SS-G2 □ T-Branch Joint (≤ 144,000 Btu/h)……………….…....CMY-Y102LS-G2 □ T-Branch Joint (≤ 234,000 Btu/h)……………….........CMY-Y202S-G2 □ Header (4-Branch; ≤ 72,000 Btu/h)........………………CMY-Y104C-G □ Header (8-Branch; ≤ 144,000 Btu/h)......………………CMY-Y108C-G □ Header (10-Branch; ≤ 234,000 Btu/h)....………………CMY-Y1010C-G * Twinning Kit is necessary to combine the refrigerant flows of the modules and is sold separately. Specifications Unit Type Nominal Cooling Capacity Btu/h Nominal Heating Capacity Btu/h System PUHY-P216TSKMU-A 216,000 243,000 External Dimensions (H x W x D) In. / mm Refer to Module Data Net Weight Lbs. / kg Electrical Power Requirements Voltage, Phase, Hertz Cooling Power Input kW Heating Power Input Cooling Current (208/230V) Heating Current (208/230V) Minimum Circuit Ampacity (MCA)** kW R.L.A. R.L.A. 1,220 / 557 Module 1 PUHY-P120TKMU-A 120,000 135,000 65 x 68-29/32 x 29-5/23 / 1,650 x 1,750 x 740 697 / 316 Refer to Module Data** Module 2 PUHY-P96TKMU-A 96,000 108,000 65 x 48 8-1/16 x 29-5/32 / 1,650 x 1,220 x 740 532 / 241 208 / 230V, 3-phase, 60Hz** 16.90 Refer to System Data 19.26 52.1 / 47.1 59.4 / 53.7 Refer to System Data A Refer to Module Data** Maximum Breaker Size** A Refer to Module Data** 50** 40** Maximum Overcurrent Protection** A Refer to Module Data** 73 / 67** 57 / 52** 45 / 42** 34 / 31** Piping Diameter From Twinning Kit to Indoor Units (Brazed) (In. / mm) From Modules to Twinning Kit (Brazed) (In. / mm) Indoor Unit Sound Pressure Levels Fan Type x Quantity Airflow Rate Direct-drive Inverter Motor Output Compressor Operating Range Liquid (High Pressure) Gas (Low Pressure) Liquid (High Pressure) Gas (Low Pressure) Total Capacity Model / Quantity dB(A) CFM kW Refer to System Data 5/8 / 15.88 1-1/8 / 28.58 Refer to Module Data 1/2 / 12.7 1-1/8 / 28.58 50 to 130% of ODUs P06 ~ P96 / 2 to 46 62.5 Refer to Module Data 8% to 100% 3/8 / 9.52 7/8 / 22.2 Refer to System Data 60.0 58.0 Propeller Fan x 2 Propeller Fan x 1 11,300 6,200 0.92 + 0.92 0.92 Refer to System Data Compressor Type x Quantity Inverter-driven Scroll Hermetic x 1 Inverter-driven Scroll Hermetic x 1 Refer to Module Data Compressor Motor Output kW 8.1 7.1 Compressor Crankcase Heater kW Refrigerant R410A Refer to Module Data Lubricant MEL32 High-pressure Protection Device 601 psi / 4.15 MPa 601 psi / 4.15 MPa Refer to Module Data Overheat Protection / Thermal Switch Overheat Protection / Thermal Switch Compressor / Fan Protection Device Inverter Protection Device Overheat / Overcurrent Protection Overheat / Overcurrent Protection Blue Fin Anti-corrosion Protection: Cellulose- and polyurethane-resin coating treatment applied to condenser coil that protects it from air contaminants; ≥1μm thick; Salt Spray Test Method - no unusual rust development to 480 hours. ** Each individual module requires a separate electrical connection. Reference electrical data for each individual module. Left view PUHY-P216TSKMU-A(-BS) PUHY-P120TKMU-A(-BS) PUHY-P96TKMU-A(-BS) CMY-Y100CBK3 ø15.88(5/8) ø28.58(1-1/8) 1650(64-31/32) Twinning pipe~Outdoor unit Intake air P96 P120 Unit model Liquid c or e ø9.52(3/8) ø12.7(1/2) Gas d or f ø22.2(7/8) ø28.58(1-1/8) Outdoor unit 1 1750(68-29/32) Note 1.Connect the pipes as shown in the figure above. Refer to the table above for the pipe size. 2.Twinning pipes should not be tilted more than 15 degrees from the horizontal plane. Be sure to see the Installation Manual for details of Twinning pipe installation. 3.The pipe section before the Twinning pipe (sections "a" and "b" in the figure) must have at least 500mm(19-11/16) of straight section (*including the straight pipe that is supplied with the Twinning pipe). 4.Only use the Twinning pipe by Mitsubishi (optional parts). Component unit name Package unit name Outdoor unit 1 Outdoor unit 2 Outdoor Twinning Kit(optional parts) Liquid a Indoor unit~Twinning pipe Gas b Twinning pipe connection size Intake air Discharge air 740(29-5/32) Front view d c 30(1-3/16) f e Intake air b To indoor unit Gas Twinning pipe<optional parts> a To indoor unit Liquid Twinning pipe<optional parts> Outdoor unit 2 1220(48-1/16) Module : PUHY-P216TSKMU-A – DIMENSIONS PUHY-P216TSKMU-A(-BS) Unit : mm(in.) 57 (2-1/4) Left side view 20 20 (13/16) (13/16) 586(23-3/32) 19.5 (25/32) 57 (2-1/4) Refrigerant service valve <liquid> Refrigerant service valve <gas> Service panel Intake air Control box 223 (8-25/32) Intake air Discharge air 2X7-ø4.6(3/16) Hole (Make hole at the plastic fan guard for snow hood attachment) <Snow hood attachment hole> 172 (6-25/32) 54(2-5/32) (23-5/8) =(5-29/32)X4 600=150X4 (2-25/32) 70 (8-9/16) 217 3 6 1 58(2-5/16) 140(5-17/32) 7 Front view 4 Top view 2 795(31-5/16) (Mounting pitch) Bottom view (Mounting pitch) 795(31-5/16) Refrigerant service valve <gas> 150(5-29/32) 83(3-9/32) Refrigerant service valve <liquid> 5 561(22-3/32) 590(23-1/4) 516(20-11/32) 49(1-15/16) 831(32-23/32) 1750(68-29/32) 831(32-23/32) 75(2-31/32) 541(21-5/16) 562(22-5/32) 80 (3-5/32) 196 (7-23/32) 151 (5-31/32) 121 (4-25/32) 77 (3-1/16) 89 (3-17/32) 145 (5-23/32) 84 (3-5/16) Gas Diameter ø12.7 (1/2) ø28.58 (1-1/8) Gas Service valve Liquid 7 6 5 4 3 2 1 NO. Specifications 140 × 77 Knockout hole (5-17/32) (3-1/16) For pipes 150 × 94 Knockout hole Bottom through hole (5-29/32) (3-23/32) Knockout hole Front through hole ø62.7 or ø34.5 (2-15/32) (1-3/8) Knockout hole Front through hole ø43.7 or ø22.2 (1-3/4) (7/8) For wires Bottom through hole ø65 Knockout hole (2-9/16) Bottom through hole ø52 Knockout hole (2-1/16) For transmission cables Front through hole ø34 Knockout hole (1-11/32) Front through hole Usage *1 Expand the on-site piping and connect to the refrigerant service valve piping. *2 Use the pipe joint(field supply) and connect to the refrigerant service valve piping. *3 Indicates dimensions and connection specifications in the case the unit is used in combination with other outdoor units. *4 Furthest piping length (OU from IU) > = 40m(131ft) 2X3-14(9/16)X20(13/16) Oval hole 80 (3-5/32) Liquid Refrigerant pipe ø9.52 Brazed (3/8) *2 PUHY-P120TKMU (ø12.7 Brazed) (1/2) *1 *3 *4 ø28.58 Brazed (1-1/8) *2 ø12.7 Brazed PUHY-P144TKMU (1/2) *1 Model Connecting pipe specifications 2X2-80(3-5/32)X35(1-13/32) Oval hole <Sling hole> Fan box Service panel Intake air 19.5 (25/32) 740(29-5/32) 29.5 (1-3/16) (26-13/16) 681(678~684) (26-23/32~26-15/16) (Mounting pitch) (740)(29-5/32) Note1.Please refer to the next page for information regarding necessary spacing around the unit and foundation work. 2.At brazing of pipes, wrap the refrigerant service valve with wet cloth and keep the temperature of refrigerant service valve under 120°C(248°F). PUHY-P120,144TKMU-A(-BS) 29.5 (1-3/16) 94 (3-23/32) 1347(53-1/16) 303 (11-15/16) 1650(64-31/32) Module : PUHY-P120TKMU-A or 144TKMU-A – DIMENSIONS Unit : mm(in.) 57 (2-1/4) Left side view 20 20 (13/16) (13/16) 586(23-3/32) Discharge air 57 (2-1/4) (6-25/32) 172 19.5 (25/32) 150(5-29/32) 4 251 272 80 (3-5/32) Refrigerant service valve <liquid> 6 5 (10-23/32) 272 (11-7/8) 301 (8-15/16) 227 (10-23/32) (9-29/32) 3 Intake air Control box Refrigerant service valve <liquid> Refrigerant service valve <gas> 4X5-ø4.6(3/16) Hole (Make hole at the plastic fan guard for snow hood attachment) <Snow hood attachment hole> 222 (8-3/4) Intake air 54(2-5/32) (23-5/8) (2-25/32) =(5-29/32)X4 600=150×4 70 (8-9/16) 217 196 (7-23/32) 146 (5-3/4) 121 (4-25/32) Front view 75(2-31/32) 58(2-5/16) 140(5-17/32) 1 Bottom view 1060(41-3/4) (Mounting pitch) valve <gas> 2 Refrigerant service 150(5-29/32) 83(3-9/32) 7 Top view 1220(48-1/16) 1181(46-1/2) 77 (3-1/16) 89 (3-17/32) 145 (5-23/32) 84 (3-5/16) 2X2-14(9/16)X20(13/16) Oval hole 80 (3-5/32) Liquid Gas Refrigerant pipe Diameter ø9.52 Brazed (3/8) *1 ø22.2 Brazed PUHY-P96TKMU (ø12.7 Brazed) (7/8) *2 (1/2) *2 *3 Model Connecting pipe specifications ø9.52 (3/8) ø28.58 (1-1/8) Gas Service valve Liquid 7 6 5 4 3 2 1 NO. Specifications 140 × 77 Knockout hole Front through hole (5-17/32) (3-1/16) For pipes 150 × 94 Knockout hole Bottom through hole (5-29/32) (3-23/32) Knockout hole Front through hole ø62.7 or ø34.5 (2-15/32) (1-3/8) Knockout hole Front through hole ø43.7 or ø22.2 (1-3/4) (7/8) For wires Bottom through hole ø65 Knockout hole (2-9/16) Bottom through hole ø52 Knockout hole (2-1/16) For transmission cables Front through hole ø34 Knockout hole (1-11/32) Usage *1 Expand the on-site piping and connect to the refrigerant service valve piping. *2 Use the pipe joint(field supply) and connect to the refrigerant service valve piping. *3 Furthest piping length (OU from IU) > = 90m(295ft) 2X2-80(3-5/32)X35(1-13/32) Oval hole <Sling hole> Service panel Intake air 19.5 (25/32) 740(29-5/32) 29.5 (1-3/16) (26-13/16) 681(678~684) (26-23/32~26-15/16) (Mounting pitch) (740)(29-5/32) Note1.Please refer to the next page for information regarding necessary spacing around the unit and foundation work. 2.At brazing of pipes, wrap the refrigerant service valve with wet cloth and keep the temperature of refrigerant service valve under 120°C(248°F). PUHY-P96TKMU-A(-BS) 29.5 (1-3/16) 94 (3-23/32) 1650(64-31/32) 303 (11-15/16) 1347(53-1/16) Module : PUHY-P96TKMU-A – DIMENSIONS Unit : mm(in.) CMY-Y100CBK3 Twinning Kit: CMY-Y100CBK3 For Gas pipe: For Liquid pipe: 19-29/32" 7-7/32" 1" 7/8" <Reducer(Accessory)> 1/2" 1/2" 5/8" 1/2" Local brazing 3-7/8" Pipe cover (Dot-dashed part) Local brazing 1/2" 6-5/16" 1-1/8" Ref.: CMY_Y100VBK2_EXD_EUDB_SI in. 1-1/8" Note 2 13-15/32" 23-5/32" ID: Inner Diameter Distributer Pipe cover (Dot-dashed part) 1" 1/2" 2-15/32" (2 pcs.) Distributer 1/2" 1-15/16" 1-1/8" 7/8" Note 2 3-9/32" 5/8" 1-15/16" (2 pcs.) 7/8" 5/8" 3/8" 3/4" 7/8" 2-15/32" (2 pcs.) 9-1/2" OD: Outer Diameter Note 1. Reference the attitude angle of the branch pipe below the fig. 15 Distributer The angle of the branch pipe for high pressure is within 15 against the horizontal plane. 2. Use the attached pipe to braze the port-opening of the distributer. 3. Pipe diameter is indicated by inside diameter. 4. Only use the Twinning pipe by Mitsubishi (optional parts) . Notes: Mitsubishi Electric Air Conditioning & Refrigeration Systems Wo rks acquired ISO based on a review of quality warranties for the production of refrigeration and air conditioning equipment. ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality warranties as development, production, installation and auxiliary services" for products built at an authorized plant. Mitsubishi Electric Sales Canada Inc. www.MitsubishiElectric.ca Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental The ISO 14000 series is a set of standards applying to environmental protection set by the International Standard Organization (ISO). Specifications are subject to change without notice. SB_PUHY-P216TSKMU-A_201206a
Similar documents
Specifications
the production of refrigeration and air conditioning equipment. ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality management as stipulated by the ISO....
More informationModel: 16-TON PUHY-P192YSJMU-A-BS
Outdoor VRFZ Heat Pump SYSTEM FEATURES • 3-phase, 460V • Modular variable refrigerant flow zoning (VRFZ) systems; smaller capacity units can be piped together to form a single, large-capacity two-p...
More information