ModelFTV - Goldberg Systems GmbH
Transcription
ModelFTV - Goldberg Systems GmbH
innovation in energy innovation in energy FTV Model EV/HEV Battery Module Testing System FEATURES & BENEFITS • Drive simulations with standard Electric Vehicle tests: FUDS, SFUDS, GSFUDS, DST and ECE-15L • Drive Cycle Conversion utility automates test program development from acquired battery usage data • Test control and data management with Bitrode’s VisuaLCN Lab Client software suite • Constant Current, Power or Voltage Control • Bipolar capacity for discharging to below zero volts • Parallel circuit operation for greater flexibility in test specification • Assignable Data Channels • Discharge power recycled to AC line for cooler, more energy-efficient operation • No performance loss under voltage control • Remote Binary Protocol via Ethernet connection available for 3rd party software control • Program execution is independent from the PC with VisuaLCN software System Options Bitrode Model FTV-2-400-12 GENERAL SPECIFICATIONS Voltage: Current: Power: Maximum Channels: Accuracy: Data Sampling Rate: 0-100V up to 1000A (2000A in parallel) up to 100kW (200kW in parallel) 4 ±0.1% of FS* up to 10ms • Multiple current ranges per circuit • High impedance cell voltage monitoring • Temperature monitoring • Pressure monitoring • Internal resistance • Ramp charge/discharge • Programmable analog or digital inputs and digital outputs • Remote Input Output (RIO) box - reduces excessive cable lengths when connecting to remote test stations • Module-front LCD display • Constant resistance discharge • Custom-designed test leads • Custom-designed cell or battery handling fixtures • Integration with Battery Management Systems: CAN *Accuracy values are conservative assuming operation will be through the standard temperature range of 0-40˚ C and RH from 10-90% (non-condensing). Units calibrated and maintained in a temperature and humidity controlled environment can expect an accuracy of 0.02-0.05%FS. Bitrode, Inc.©2012 www.bitrode.com innovation in energy innovation in energy FTV Model EV/HEV Battery Module Testing System General Configurations - Contact bitrode for your custom specification requirements Model* FTV4-300-20 FTV4-500-20 FTV4-100-60 FTV4-200-60 FTV4-300-100 FTV4-500-100 Constant Current Amp Range (A) per ciruit/per cabinet 0.0-300.0/1200.0 0.0-500.0/2000.0 0.00-100.00/400.00 0.00-200.00/800.00 0.0-300/1200.0 0.0-500.0/2000.0 Cabinet Input Amps (A) (50 or 60HZ) Model* Three Phase 380V400V415V480V FTV4-300-20 90 85 80 70 FTV4-500-20 120 115 110 95 FTV4-100-60 85 80 75 65 FTV4-200-60 120 115 110 95 FTV4-300-100 260 245 240 204 FTV4-500-100 460 440 425 365 Charge/Discharge Voltage (V) 0.000-20.000 0.000-20.000 0.00-60.00 0.00-60.00 0.00-100.00 0.00-100.00 Constant Wattage (kW) per circuit/per cabinet 6.000/24.000 10.000/40.000 6.000/24.000 12.000/48.000 30.00/120.00 50.00/200.00 Dimensions†Weight† in/cm lb/kg W D H 57/145 35/89 78/199 2800/1273 57/145 35/89 78/199 3200/1455 57/145 35/89 78/199 2100/955 57/145 35/89 78/199 2700/1227 57/145 35/89 78/199 3400/1545 105/267 31/79 86/219 4700/2136 * If required specifications do not appear in this table, contact Bitrode Corporation; custom product engineering is one of our greatest strengths. Module names are interpreted as follows: FTVx-yy-zz, where xx indicates number of circuits per cabinet, yy indicates amperage and zz indicates voltage. † Dimensions and Weight may vary according to design requirements. All specifications subject to change. BITRODE CORPORATION 9787 Green Park Industrial Drive St. Louis, Missouri 63123 USA Tel: (636) 343.6112 • Fax: (636) 343.7473 email: [email protected] web: www.bitrode.com BITRODE EU/SOVEMA SPA via Spagna, 13 37069 Villafranca (Verona), Italy Tel: +39.045.6335711 • Fax: +39.045.6303911 Contact Person: Mr. Roberto Vecchia Tel: +39.045.6335725 • Mobile: +39.331.6338697 email: [email protected] BITRODE UK OFFICE Tel: 44 1242 23111 Contact Person: Mr. Graham Peters email: [email protected]