GB Amprobe Katalog 2006 Teil 1
Transcription
GB Amprobe Katalog 2006 Teil 1
Welcome into the future ELECTRICAL CAT CA TALOGUE CATALOGUE 2006 17 Overview Average Value Recording Multimeters AM - 42 AM - 45, AM - 47 AM - 220, AM-240 AM - 100 True RMS Multimeter AM - 105 TRMS AM - 110 TRMS, AM-120 TRMS AM - 130 TRMS, AM-150 TRMS AM - 140 TRMS, AM-160 TRMS Digital Multimeters Accessories Pen Style Digital Multimeters PMM - 2C 31 7 8 9 11 11 12 13 14 15 16 Digital Clamp-Ons Overview Average Value Recording Clamp-Ons ACD - 6 Pro, ACD-10 Pro ACD - 14, ACD-15 Pro (to 2000 AC) ACDC - 400, ACD-16 Pro True RMS Clamp-Ons ACD - 6 Pro TRMS, ACD-10 Pro TRMS ACD - 14 Pro TRMS, ACD-15 Pro TRMS ACD - 16 TRMS PRO ACD - 30P, ACD-31P (Power Clamp-On 1000 A) ACD - 40PQ, ACD-41PQ (Power Clamp-On 1000 A) ACD - 50er Series (Net Analysis 600 A) ACD - 330 T (AC-Clamp-On 1000 A) ACDC - 620 T (AC/DC-Clamp-On 1000 A) ACDC - 3000 (AC/DC-Clamp-On 1000 A) Clamp-On Transducer A - 1000 (AC/DC 1000 A) A - 300, A - 400 (Current Transducer to 300 A AC) CT - 30 (AC/DC to 40 A) ACF - 3000 - AK (Flexible Current) ACF - 3003 (Flexible Current up to 3000 A) ACF - 3000 DM-A (Flexible Current) ACF - 3000 SR (Flexible Current) Leakage Current Clamp DLC - 100 (up to 10 μA AC) 18 19 20 21 19 20 21 22 23 25 26 26 27 27 28 28 29 29 29 29 30 VDE Test Instruments Overview 33 e-manager pro (Professional Sixteenth Edition Software) 34 WEP-IIM (Workshop Kit) 36 WEP-5P (Workshop Kit) 37 ULTRA 0701/0702S 38 ABA-1 39 ULTRA 0751 39 AUTOTEST 0701/2S 40 AUTOTEST 0701/0702 plus 0751 41 PAT Tester 0701/0702S 42 PAT Tester 0751 plus 43 e-tester 0701/0702 44 Transponders 45 TP Handheld reader USB 45 Powertest 0701/0702 3P 46 MT-100 48 Genius 5035 (VDE 0100 Tester) 50 Genius 80 E (VDE 0100 Tester) 51 Genius 5035/80 E (Adapters and Accessories) 53 Combitest 2019 (VDE 0100 Tester) 55 Insulation Tester 2010 (Megohmmeter 1 kV) 56 SPEEDTEST 2018 (RCD-Tester) 56 GEOTEST 2016 (Ground Resistance Tester) 57 DGC-1000 A (Ground Resistance Clamp) 58 AMB-25, AMB-35 (Insulation Tester 1 kV) 59 MEGATEST-1 (Insulation Tester 1 kV) 60 Insulation Tester AMB-5 kV (Insulation Tester 5 kV) 60 ISO-Digi 5 kV (Insulation Tester 5 kV) 61 SAFETEST (Machine Tester) 62 ALLTEST (Machine Tester) 63 PRM-2, PRM-3 (Phase Rotation Meter) 64 6 65 5 Digital Multimeters Power Analysis Harmonics and Power Analysis GSC-53 A (VDE 0100 + Power Analyser) ENERGYTEST 2020 E (Hand Held Power Analyser) DM-4 (3-Phase Power Analyser) DM-II (3-Phase Power Analyser) 66 68 70 72 Amprobe Mönchengladbach · Germany Amprobe Europe GmbH Lürriper Straße 62 · D-41065 Mönchengladbach · Germany Telephone +49 (0) 21 61- 59 90 6-0 · Telefax +49 (0) 21 61- 59 90 6-16 www.amprobe.de · [email protected] Prices and technical specifications are subject to eventual changes, literal mistakes are excempt from liability. AMPROBE EUROPE 10/05 2 81 W - GT 1 Multitest Digital Ω KWIK - I - E Electrical and Power Quality Test Equipment (Non-Contact Volt Probe) (Non-Contact Volt Probe) (Magnetic Tester) (Voltage Tester with Solar Cell and Lithium Accumulator) (Belt Set) (Volt Probe LED) (Volt Probe LCD) (Non-Contact Volt Probe) 86 86 86 89 89 90 91 92 HVAC/R Service and Test Equipment Accessories Table of Contents 93 82 82 83 83 83 84 84 85 85 85 88 88 88 94 95 96 97 Interface Cable C-2001, MVK-02s, RS-232 Cable 0701/2s 99 Autotest RS-232 Cable, Autotest Adaptercable PDA 99 RS-Jack 99 USB to RS 232 Adapter 100 Sensing Line for Multimeter & Digital Clamp-Ons DTL-ABNC, DTL-1000, EU-200, MTL-90B, PMTL-5 100 Adaptercable for Digital Clamp-Ons ACF-5A CE, ACF-6, ACF-6A 101 Accessories for VDE 0100 Test Equipment COC2, COC3, COC4 101 TPII-2, TLR-1F, TLP2, TLP3, TLB4-KitGE80, SP3 102 TLE4, MR4 103 Accessories for VDE 0701/0702 Test Equipment SP-3 ABL, TLP-0701, R-PE Cable 0701/2s, DVA-16 103 Bar code scanner for VDE 0701/0702 Test Equipment BC-Scanner for Autotest 104 BC-Scanner USB, BC-Scanner PS/2 104 BC-Pen for Autotest 104 Equipment-Protective Bag SV-U, CC-ACDC, CN0050 105 WP2000S, WP2000, WP2050 105 Test and Measurement Tools VP - 440 VP - 600 MT - 1000L LSP - 2 Leak Detectors High Speed – High Quality TIF ZX -1E (Refrigerant Leak Detectors) TIF XL-1A/RX-1A/XP-1A (Refrigerant Leak Detectors) TIF 8800I/8800AI/8850I (Combustible Gas Detectors) Temperature-ClimateEnvironment Digital Temperature Measurement Instruments TH - 2A (Temperature + Humidity) THWD - 2 (Temperature + Humidity) RA 43240 (Temperate Probe) DT -130 (Temperate Probe) DT -136 (Temperate Probe) LT -100, ST - 20 (Infrared Thermometer) TMA - K, TL -10 S (Adapter) TPK -56, TPK -59 (K-Temperature Adapter) TC-11, TC-12, TC-13, TC-14 (K- Thermocouples) LM - 80 (Lightmeter) Ultrasonic Leak Detectors TMULD - 300 (Leak Detector Kit) ULD - 300 (Ultrasonic Detector) UT - 300 (Ultrasonic Transmitter) 87 74 75 76 76 77 79 80 98 Wire Location and Tracing AT - 2000 (Advanced Tracer) ATGC - 1 (Advanced Tracer Ground Coil) AT - 2000 Accessories AT - 1000 AT - 3000 (Cable Tracing) LEXXI T 810 (Reflectometer) TDR - 400 (Reflectometer) 106 73 Wire Tracer/Wire Location Appendix Accessories and Replacements (for DMM’s + Clamp-Ons) Accessories for VDE Test Instruments Electrical Terms/Vocabulary Helpful Hints/AT-3000 Userguide Product Index Refrigerant Recovery Machines 106 108 110 111 115 HVAC/R Recovery, Tools and Evacuation Systems 3 Amprobe News AM-220 Digital Ω Digital Multimeter Digital Volt Probe Page 9 ACD-6 Pro MT-100 Digital Clamp-On up to 1000 A AC Multimeter and Installation Tester Page 19 4 Page 91 Page 48 Digital Multimeters 333 5 6 Page 9 Catalogue Page Number *) 15 A for 30 sec, **) 20 A for 30 sec 77x158x45 290 g 600 V 1 mV 600 V 1 mV 40 MΩ 0,1 Ω 40 nF … 4000 μF 0,01 nF 10 MHz 0,01 Hz 13 • • au. + opt. • 10 A *) 1μA 10 A *) 1μA AM-220 3 1/2 2000 Dimension W x H x D Weight Special Duty Cycle V~ Resolution V= Resolution Ω Resolution C Resolution Hz Resolution Temperature Analog Bar graph digit Hight (mm) Back Light HOLD-Function Continuity Test Auto Power Off A~ Resolution A= Resolution True RMS Features Display digits max. 600 V 1 mV 600 V 1 mV 6 MΩ 0,1 Ω 2000 μF 0,1 nF 30 kHz 0,01 Hz • au. + opt. • 2A 1 μA 2A 1μA 20 AM-47 3 5/6 6000 77x158x45 71x122x14 71x122x14 71x122x14 290 g 100 g 100 g 100 g Non-Contact Non-Contact with temperature Automatic ACV, probe DCV and Voltage Detection Voltage Detection Resitance Selection Page 9 Page 7 Page 8 Page 8 1 MHz 0,001 Hz 0,01 nF 10 MHz 0,01 Hz -50 ~ 700 °C 450 V 1 mV 450 V 1 mV 6 MΩ 0,1 Ω 2000 μF 0,1 nF 30 kHz 0,01 Hz • au. + opt. • • au. + opt. • 600 V 1 mV 600 V 0,1 mV 40 MΩ 0,1 Ω 20 AM-45 3 5/6 6000 20 AM-42 3 3/4 4000 600 V 1 mV 600 V 1 mV 40 MΩ 0,1 Ω 13 • • au. + opt. • 10 A *) 1μA 10 A *) 1μA AM-240 3 1/2 2000 Overview Digital Multimeters Page 11 97x198x55 430 g 1000 V 0,1 mV 1000 V 0,1 mV 40 MΩ 0,1 Ω 3 mF 0,1 nF 1 MHz 0,001 Hz • au. + opt. • 10 A 0,1μA 10 A 0,1μA 25 AM-100 3 3/4 4000 Page 11 97x198x55 430 g 1000 V 0,1 mV 1000 V 0,1 mV 40 MΩ 0,1 Ω 3 mF 0,1 nF 1 MHz 0,001 Hz • au. + opt. • 10 A **) 0,1μA 10 A 0,1μA • 25 AM-105 TRMS 3 3/4 4000 Page 12 97x198x55 430 g 1000 V 0,1 mV 1000 V 0,1 mV 40 MΩ 0,1 Ω 3 mF 0,1 nF 1 MHz 0,001 Hz -20 ~ 300 °C with Adapter TPK-59 25 • • au. + opt. • 10 A **) 0,1μA 10 A 0,1μA • AM-110 TRMS 3 3/4 4000 Page 12 97x198x55 430 g with Interface 1000 V 0,01 mV 1000 V 0,01 mV 50 MΩ 0,01 Ω 9,999 mF 0,1 nF 125 kHz 1 Hz AM-120 TRMS 3 4/5 5000 52 Segm. 15 • • au. + opt. • 10 A **) 0,1μA 10 A 0,1μA • Page 13 97x198x55 430 g with Interface 1000 V 0,01 mV 1000 V 0,01 mV 50 MΩ 0,01 Ω 9,999 mF 0,1 nF 125 kHz 1 Hz -50 ~ 1000 °C AM-130 TRMS 3 4/5 5000 52 Segm. 15 • • au. + opt. • 10 A **) 0,1μA 10 A 0,1μA • Page 14 0,1 % 99,99 % 97x198x55 430 g with Interfacee 1000 V 0,01 mV 1000 V 0,01 mV 50 MΩ 0,01 Ω 9,999 mF 0,01 nF 2 MHz 0,0001 Hz AM-140 TRMS 4 4/5 50000 52 Segm. 15 • • au. + opt. • 10 A **) 0,1μA 10 A 0,1μA • 97x198x55 430 g with Interface and Data logger 5400 points Page 13 1000 V 0,01 mV 1000 V 0,01 mV 50 MΩ 0,01 Ω 9,999 mF 0,1 nF 125 kHz 1 Hz -50 ~ 1000 °C AM-150 TRMS 3 4/5 5000 52 Segm. 15 • • au. + opt. • 10 A **) 0,1μA 10 A 0,1μA • Page 14 97x198x55 430 g with Interface 1000 V 0,01 mV 1000 V 0,01 mV 50 MΩ 0,01 Ω 9,999 mF 0,01 nF 2 MHz 0,0001 Hz -50 ~ 1000 °C AM-160 TRMS 4 4/5 50000 52 Segm. 15 • • au. + opt. • 10 A **) 0,1μA 10 A 0,1μA • Page 16 74x225x34 270 g Pen Style Multimeter 600 V 1 mV 600 V 1 mV 42 MΩ 0,1 Ω • au. + opt. 10 min 300 A (Transducer) PMM-2C 3 3/4 4200 65 Segm. 13 333 Digital Multimeters AM-Series – Pocket DMM Digital Multimeter AM-42 Pocket DMM Digital Multimeter • Oversized, large LCD easy to read • Automatic ACV, DCV and Resistance selection • Data Hold • Auto power off • Audible continuity • 30 ms Peak Hold • Autoranging • Safety CAT III 300 V, CAT II 600 V AM-42 Carrying Case CC-AM-40 Function DC Voltage AC Voltage Resistance Frequency Capacitance Diode test Gerneral Data Standard Accessories Range Resolution 400.0 mV … 600.0 V 0,1 mV … 1,0 V 4.000 V … 600.0 V 0,001 V … 1,0 V 400.0 Ω … 40.00 MΩ 0,1 Ω … 0,01 MΩ 5.000 Hz … 1.000 MHz 0,001 Hz 500.0 nF … 3000 μF 0,1 nF … 1 μF 0,25 mA Weight: 100 g, L x W x H: 71 x 122 x 14 mm incl. batteries, test leads and manual Accuracy ± (1,0 % rdg + 3 digits) ± (3,5 % rdg + 5 digits) ± (2,5 % rdg + 4 digits) ± (0,5 % rdg + 5 digits) ± (3,5 % rdg + 6 digits) 7 AM-45 Pocket DMM Digital Multimeter • Oversized, large LCD easy to read • Non-contact voltage detection for user safety • Automatic ACV, DCV and Resistance selection • Data Hold • Auto power off • Audible continuity • Autoranging • Safety CAT II 450 V AM-45 Carrying Case CC-AM-40 Function DC Voltage AC Voltage Resistance Frequency Capacitance Non-contact Voltage Detection General Data Standard Accessories Range Resolution Accuracy 6.000 V … 450.0 V 0,001 V … 0,1 V ± (1,5 % rdg + 5 digits) 6.000 V … 450.0 V 0,001 V … 0,1 V ± (1,5 % rdg + 5 digits) 600.0 Ω … 6.000 MΩ 0,1 Ω … 0,001 MΩ ± (2,0 % rdg + 6 digits) 10.00 Hz … 30.00 kHz 0,01 Hz ± (0,5 % rdg + 5 digits) 100.0 nF … 100.0 μF 0,1 nF … 1 μF ± (3,5 % rdg + 6 digits) Bargraph Indication: 15 V - 55 V, 30 V - 85 V, 55 V - 145 V, 85 V - 190 V, 120 V - 450 V Weight: 100 g, L x W x H: 122 x 71 x 14 mm incl. batteries, test leads and manual AM-47 Pocket DMM Digital Multimeter • Oversized, large LCD easy to read • Non-contact voltage detection for user safety • μA AC/DC Function • Automatic ACV, DCV and Resistance selection • Data Hold • Auto power off • Audible continuity • Autoranging • Safety CAT III 300 V, CAT II 600 V AM-47 Carrying Case CC-AM-40 Function DC Voltage AC Voltage Resistance AC/DC uA Current Frequency Capacitance Diode test Non-contact Voltage Detection General Data Standard Accessories 8 Range Resolution Accuracy 6.000 V … 600.0 V 0,001 V … 0,1 V ± (1,5% rdg + 5 digits) 6.000 V … 600.0 V 0,001 V … 0,1 V ± (1,5% rdg + 5 digits) 600.0 Ω … 6.000 MΩ 0,1 Ω … 0,001 MΩ ± (2,0% rdg + 6 digits) 0 - 400 μA/2000 μA 1 μA ± (2,0% rdg + 3 digits) 10.00 Hz … 30.00 kHz 0,01 Hz ± (0,5% rdg + 5 digits) 100.0 nF … 2000 μF 0,1 nF … 1μF ± (3,5% rdg + 6 digits) 0,48 mA Bargraph Indication: 15 V - 55 V, 30 V - 85 V, 55 V - 145 V, 85 V - 190 V, 120 V - 600 V Weight: 100 g, L x W x H: 122 x 71 x 14 mm incl. batteries, test leads and manual 333 • Large LCD display with back light • Auto and manual ranging • MAX/MIN function • AC/DC Current 1μA up to 10 A • Resistance up to 40 MOhm • Frequency measurement • Capacity measurement • Data Hold • Diode check • Audible continuity check • Auto power off • Safety CAT III 600 V Function AC/DC Current AC/DC Volts Resistance Frequency Capacitance Weight/Dimension Standard Accessories Range 400 μA … 10.00 A 400 mV … 600 V 400.0 Ω … 40.00 MΩ 10.00 Hz … 10 MHz 40,00 nF … 4000 μF 290 g, W x H x D: 77 x 158 x 45 mm incl. batteries, test leads and manual Resolution 1 μA … 1 A 1 mV … 1 V 0,1 Ω … 0,01 MΩ 0,01 Hz … 1 MHz 0,01 nF … 1 μF Digital Multimeters AM-220 The Cost-Saving AM-220 Carrying Case SV-U Accuracy ± (1,5 % rdg + 3 digits) AC, ± (1,2 % rdg + 2 digits) DC ± (1,0 % rdg + 2 digits) AC, ± (0,5 % rdg + 2 digits) DC ± (1,0 % rdg + 2 digits) ± (0,1 % rdg + 5 digits) ± (2,5 % rdg + 5 digits) AM-240 The Cost-Saving with Temperature measurement • Large LCD display with back light • Auto and manual ranging • MAX/MIN function • AC/DC Current 1μA up to 10 A • Resistance up to 40 MOhm • Frequency measurement • Capacity measurement • Temperature measurement • Data Hold • Diode check • Audible continuity check • Auto power off • Safety CAT III 600 V Function AC/DC Current AC/DC Volts Resistance Frequency Capacitance Temperature Weight/Dimension Standard Accessories Range Resolution 400 μA … 10.00 A 1 μA … 1 A 400 mV … 600 V 1 mV … 1 V 400.0 Ω … 40.00 MΩ 0,1 Ω … 0,01 MΩ 10.00 Hz … 10 MHz 0,01 Hz … 1 MHz 40,00 nF … 4000 μF 0,01 nF … 1 μF - 50°C … 700°C 1°C 290 g, W x H x D: 77 x 158 x 45 mm incl. batteries, temperature probe, test leads and manual AM-240 Carrying Case SV-U Accuracy ± (1,5 % rdg + 3 digits) AC, ± (1,2 % rdg + 2 digits) DC ± (1,0 % rdg + 2 digits) AC, ± (0,5 % rdg + 2 digits) DC ± (1,0 % rdg + 2 digits) ± (0,1 % rdg + 5 digits) ± (2,5 % rdg + 5 digits) 1% +/- 2°C 9 AM-100 Series – Professional Series Digital Multimeters AM-100 AM-105 TRMS AM-110 TRMS AM-120 TRMS AM-130 TRMS AM-140 TRMS AM-150 TRMS AM-160 TRMS Digital Multimeters True RMS Backlight Display AC Voltage DC Voltage AC Current μA/mA/A Resistance Audible continuity Temperature Frequency measurement Capacitance Diode Test Duty Cycle Data recording Max, Min, Peak Data Logger Auto ranging Data Hold PC Connection 10 AM-100 AM-105 TRMS AM-110 TRMS AM-120 TRMS AM-130 TRMS AM-140 TRMS AM-150 TRMS AM-160 TRMS • • • 1000 V 1000 V •/•/• • • 1000 V 1000 V •/•/• • • 1000 V 1000 V •/•/• • • 1000 V 1000 V •/•/• • • 1000 V 1000 V •/•/• • • 1000 V 1000 V •/•/• • • • • • • • • • • • • • • • • • • • • • • • • Max, Min, Peak • • • • Max, Min, Peak • • • • Max, Min, Peak • • • • • • 1000 V 1000 V •/•/• 1000 V 1000 V •/•/• • • • • • • • • • • • • • • • • • only Max • only Max • only Max • • • • • • • • • • • Max, Min, Peak 5400 Points • • • • • • 333 • Peak Hold (25 ms response time) • Auto and manual ranging • Large, easy to read LCD display • Auto power off • Data Hold • Diode Test, Audible continuity • Relative zero mode • Safety CAT III 600 V, CAT II 1000 V AM-100 Carrying Case SV-U Hard Case CC-TAM-100 Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance General Data Standard Accessories Range Resolution 400.0 μA … 10.00 A (20 A for 30 sec) 0,1 μA … 1 A 400.0 mV … 1000 V 0,1 mV … 1 V 400.0 Ω … 40.00 MΩ 0,1 Ω … 0,01 MΩ 50.00 Hz … 1.000 MHz 0,001 Hz … 1 MHz 500.0 nF … 3000 μF 0,1 nF … 1 μF Weight: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B and manual Digital Multimeters AM-100 Basic Model Accuracy ± (2,0 % rdg + 2 digits) ± (1,5 % - % rdg + 5 digits) AC/± (0,5 % - % rdg + 3 digits) DC ± (2,0 % rdg + 2 digits) ± (0,5 % rdg + 4 digits) ± (3,5 % rdg + 6 digits) AM-105 TRMS Basic Model with TRMS • TRMS • Peak Hold (25 ms response time) • Auto and manual ranging • Large, easy to read LCD display • Auto power off • Data Hold • Diode Test, Audible continuity • Relative zero mode • Safety CAT III 600 V, CAT II 1000 V AM-105 TRMS Carrying Case SV-U Hard Case CC-TAM-100 Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance General Data Standard Accessories Range Resolution 400.0 μA … 10.00 A (20 A for 30 sec) 0,1 μA … 1 A 400.0 mV … 1000 V 0,1 mV … 1 V 400.0 Ω … 40.00 MΩ 0,1 Ω … 0.01 MΩ 50.00 Hz … 1.000 MHz 0,001 Hz … 1 MHz 500.0 nF … 3000 μF 0,1 nF … 1 μF Weight: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B and manual Accuracy ± (2,0 % rdg + 2 digits) ± (1,5 % - % rdg + 5 digits) AC/± (0,5 % - % rdg + 3 digits) DC ± (2,0 % rdg + 2 digits) ± (0,5 % rdg + 4 digits) ± (3,5 % rdg + 6 digits) 11 AM-110 TRMS TRMS Multimeter with Temperature-Function • TRMS • Peak Hold (25 ms response time) • Auto and manual ranging • Large, easy to read LCD display • Temperature measurement * • Auto power off • Data hold • Backlight display • Diode Test, Audible continuity • Relative zero mode • Safety CAT III 600 V, CAT II 1000 V AM-110 TRMS Carrying Case SV-U Hard Case CC-TAM-100 Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance Temperature* General Data Standard Accessories Range Resolution 400.0 μA … 10.00 A (20 A for 30 sec) 0,1 μA … 1 A 400.0 mV … 1000 V 0,1 mV … 1 V 400.0 Ω … 40.00 MΩ 0,1 Ω … 0,01 MΩ 50.00 Hz … 1.000 MHz 0,001 Hz … 1 MHz 500.0 nF … 3000 μF 0,1 nF … 1 μF - 20° C … 300° C 1° C Weight: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B and manual Accuracy ± (2,0 % rdg + 2 digits) ± (1,5 % rdg + 5 digits) AC/± (0,5 % rdg + 3 digits) DC ± (2,0 % rdg + 2 digits) ± (0,5 % rdg + 4 digits) ± (3,5 % rdg + 6 digits) 2 % + 3° C * with Thermocouple TPK-59 AM-120 TRMS TRMS Digital Multimeter with PC Connection • TRMS • Auto and manual ranging • Optical isolated PC interface capability • Large, easy to read LCD display • Back light display • 3 - 4/5 digits, 5000 digits • Bargraph 52 Segments • Auto power off • Data hold • Diode Test, Audible continuity • Relative zero mode • Safety CAT III 1000 V, CAT IV 600 V AM-120 TRMS Carrying Case SV-U Hard Case CC-TAM-100 RS-232 KIT 1 PC-Connection cable with software Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance General Data Standard Accessories 12 Range Resolution 500.0 μA … 10.00 A (20 A for 30 sec) 0,1 μA … 1,00 A 50.00 mV … 1000 V 0,01 mV … 1 V 50.00 Ω … 50.00 MΩ 0,01 Ω … 0,01 MΩ 5 Hz … 125 kHz 1 Hz … 1 kHz 50 nF … 9999 μF 0,1 nF … 1 μF Weight: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B and manual Accuracy ± (1,0 % rdg + 4 digits) AC/± (0,2 % rdg + 4 digits) DC ± (0,5 % rdg + 3 digits) AC/± (0,08 % rdg + 2 digits) DC ± (0,2 % rdg + 6 digits) ± (0,01 % rdg + 2 digits) ± (2,0 % rdg + 3 digits) 333 AM-130 TRMS • TRMS • Auto and manual ranging • Large, easy to read LCD display • 3 - 4/5 digits, 5000 digits • Bargraph 52 Segments • Temperature measurement • Auto power off • Data Hold • Backlight display • Diode Test, Audible continuity • Relative zero mode Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance Temperature General Data Standard Accessories Range Resolution 500.0 μA … 10.00 A (20 A for 30 sec) 0,1 μA … 1,00 A 50.00 mV … 1000 V 0,01 mV … 1 V 50.00 Ω … 50.00 MΩ 0,01 Ω … 0.01 mΩ 5 Hz … 125 kHz 1 Hz … 1 kHz 50 nF … 9999 μF 0,1 nF … 1 μF - 58° F (- 50° C) … 1832° F (1000° C) 1° F (1° C) Weigt: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B, thermocouple and manual, Thermocouple TPK-59 • Records PEAK, MAX, MIN, MAX-MIN • Optical isolated PC interface capability • Safety CAT III 1000 V, CAT IV 600 V Digital Multimeters TRMS Digital Multimeter with PC Connection AM-130 TRMS Carrying Case SV-U Hard Case CC-TAM-100 RS-232 KIT 1 PC-Connection cable with software Accuracy ± (1,0 % rdg + 4 digits) DC/± (0,2 % rdg + 4 digits) AC ± (0,5 % rdg + 3 digits) AC/± (0,08 % rdg + 2 digits) DC ± (0,2 % rdg + 6 digits) ± (0,01 % rdg + 2 digits) ± (2,0 % rdg + 3 digits) 0,3 % + 3 digits AM-150 TRMS TRMS Digital Multimeter with PC Connection and Data Logger • TRMS • Auto and manual ranging • Large, easy to read LCD display • 3 - 4/5 digits, 5000 digits • Bargraph 52 Segments • Temperature measurement • Auto power off • Data Hold • Back light display • Diode Test, Audible continuity Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance Temperature General Data Standard Accessories • Relative zero mode • Data recording 5400 Points • Recording interval selectable from 50 ms. up to 480 sec. • Optical isolated PC interface capability • Safety CAT III 1000 V, CAT IV 600 V AM-150 TRMS Carrying Case SV-U Hard Case CC-TAM-100 RS-232 KIT 1 PC-Connection cable with software Range Resolution Accuracy 500.0 μA … 10.00 A (20 A for 30 sec) 0,1 μA … 1,00 A ± (1,0 % rdg + 4 digits) DC/± (0,2 % rdg + 4 digits) AC 50.00 mV … 1000 V 0,01 mV … 1 V ± (0,5 % rdg + 3 digits) AC/± (0,08 % rdg + 2 digits) DC 50.00 Ω … 50.00 MΩ 0,01 Ω … 0,01 MΩ ± (0,2 % rdg + 6 digits) 5 Hz … 125 kHz 1 Hz … 1 MHz ± (0,01 % rdg + 2 digits) 50 nF … 9999 μF 0,1 nF … 1 μF ± (2,0 % rdg + 3 digits) - 58° F (- 50° C) … 1832° F (1000° C) 1° F (1° C) 0,3 % + 3 digits Weight: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B, thermocouple and manual, Thermocouple TPK-59 13 AM-140 TRMS Precision TRMS Digital Multimeter with PC Connection • TRMS • Relative zero mode • Data Hold, Peak Hold • Auto and manual ranging • Large, easy to read LCD display • 4 - 4/5 digits, 50.000 digits • Bargraph 52 Segments • Intelligent auto power off • Backlight display Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance Duty Cycle General Data Standard Accessories Range Resolution 500.0 μA … 10.000 A (20 A for 30 sec) 0,1 μA … 0,001 A 500.00 mV … 1000.0 V 0,01 mV … 0,1 V 500.00 Ω … 50.00 MΩ 0,01 Ω … 0,01 MΩ 5.0000 Hz … 2.0000 MHz 0,0001 Hz … 0,001 MHz 50.00 nF … 9999 μF 0,01 nF … 1 μF 0,1% … 99.99% Weight: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B and manual • dBm reading (20 selectable values) • Records PEAK, MAX, MIN, MAX-MIN • Optical isolated PC interface capability • Diode Test, Audible continuity • DC Loop current 4 - 20 mA • Safety CAT III 1000 V, CAT IV 600 V AM-140 TRMS Carrying Case SV-U Hard Case CC-TAM-100 RS-232 KIT 1 PC-Connection cable with software Accuracy ± (1,0 % rdg + 40 digits) AC/± (0,5 % rdg + 20 digits) DC ± (0,8 % rdg + 60 digits) AC/± (0,03 % rdg + 2 digits) DC ± (0,10 % rdg + 6 digits) ± (0,002 % rdg + 4 digits) ± (2,0 % rdg + 3 digits) ± (3 digits/kHz + 3 digits) AM-160 TRMS Precision TRMS Digital Multimeter with PC Connection • TRMS • Data Hold, Peak Hold • Auto and manual ranging • Temperature measurement • Large, easy to read LCD display • 4 - 4/5 digits, 50.000 digits • Bargraph 52 Segments • Intelligent auto power off • Backlight display Function AC/DC Current AC/DC Voltage Resistance Frequency Capacitance Temperature General Data Standard Accessories 14 Range Resolution 500.0 μA … 10.000 A (20 A for 30 sec) 0,1 μA … 0,001 A 500.00 mV … 1000.0 V 0,01 mV … 0,1 V 500.00 Ω … 50.00 MΩ 0,01 Ω … 0,01 MΩ 5.0000 Hz … 2.0000 MHz 0,0001 Hz … 0,001 MHz 50.00 nF … 9999 μF 0,01 nF … 1 μF - 58° F (-50° C) … 1832° F (1000° C) 1° F (1° C) Weight: 430 g, L x W x D: 198 x 97 x 55 mm incl. batteries, test leads MTL-90B, thermocouple and manual, Thermocouple TPK-59 • dBm reading (20 selectable values) • Records PEAK, MAX, MIN, MAX-MIN • Optical isolated PC interface capability • Diode Test, Audible continuity • DC Loop current 4 - 20 mA • Safety CAT III 1000 V, CAT IV 600 V AM-160 TRMS Carrying Case SV-U Hard Case CC-TAM-100 RS-232 KIT 1 PC-Connection cable with software Accuracy ± (0,5 % rdg + 50 digits) AC/± (0,5 % rdg + 20 digits) DC ± (0,8 % rdg + 20 digits) AC/± (0,05 % rdg + 2 digits) DC ± (0,07 % rdg + 2 digits) ± (0,002 % rdg + 4 digits) ± (2,0 % rdg + 3 digits) ± (0,3 % rdg + 2 F)/± (0,3 % rdg + 1 C) 333 Digital Multimeters TAM-100 Test Master Kit consisting of: Multimeter AM-100, Clamp-On ACD-10 Pro in Hard Case CC-TAM-100 TAM-100 CC-TAM-100 Hard Case CC-TAM-100 SV-U Carrying Case for AM-100 Series Multimeter SV-U USB/RS-232 Adapter USB to RS-232 adapter USB/RS-232 RS-232 Kit 1 Software with PC connecting cable for AM-100er Series RS-232 Kit 1 15 PMM-2C Clamp-On + Digital Multimeter CAT II (600 V), CAT III (300 V) • 4200 digits LCD display • Plug-in Clamp-On head • Overload protection • 42 MΩ, 600 V AC/DC, 300 A AC • Acoustic continuity check • Diode check • DATA-HOLD Function • Auto- and manual ranging • Auto power off PMM-2C Function V= Range Resolution Accuracy 0 … 420 mV … 1 mV ± 0,5 % ± 2 digits … 600 V V~ 0 … 420 mV … 1 mV ± 0,5 % ± 5 digits …600 V Ω 0 … 420 Ω … 0,1 Ω ± 1,2 % ± 8 digits … 42 MΩ 10 kΩ ± 3,0 % ± 7 digits Diode check Test voltage: 3,3 V, max test current 1,5 mA Continuity check Buzzer resounds at < 20 Ω Dimension W 74 x H 225 x D 34 mm Power supply 2 x 1,5 V Weight 120 g Standard Accessories PMM-2, PMM-C incl. carrying case + test leads Adapter function °C, relative humidity %, μA, capacity μF Input Impendance 10 MΩ Overload Protection 600 V = 10 MΩ/ < 100 pF 600 V AC RMS 600 V AC/DC RMS PMM-2 Pen Style Digital Multimeter Safety: IEC 1010-1 • extreme small and handy pen style digital multimeter • LCD display 4200 digits • AC DC voltage measurement up to 600 V • resistance measurement up to 42 MΩ • audible continuity check • diode check • inclusive test leads • Tips and carrying case PMM-2 PMM-C Clamp-On Head for PMM-2 • Current measurement from 0,4 to 300 A AC • Hand guard desing • For cables up to ø 29 mm PMM-C Range Output Max. output impedance Accuracy Weight Dimension Max. jaw opening 16 0,4 A to 300 A AC (effectiv) 1 m V pro 0,1 AMP AC 120 Ω ± (1,9 % + 0,5 A) 50 - 60 Hz 150 g 72 x 102 x 36 mm 31 mm Digital Clamp-Ons 333 17 18 600 V 40 MΩ 2 kHz • V= Ω Hz Continuity check Peak capture • • 100 kHz • 10 MΩ 600 V 600 V • 30 min 100 kHz • 40 MΩ 600 V 600 V 0,01 A 400 A ACD-14 Clamp-Ons only 0,1 A 1000 A 15 min 1 kHz • 6 MΩ 600 V 600 V • 15 min 5-500 Hz • 50 ms 1 kΩ 600 V 600 V ACD-15 Pro TRMS ACD-16 Pro TRMS only 0,1 A 2000 A • • 5-500 Hz • 50 ms 1 kΩ 600 V 600 V • 0,1 A 1000 A 2 kΩ 600 V 600 V • 0,1 A 400 A • • • • 5-500 Hz 400 Hz • • 50 ms 1 ms voltage 15 ms current 1 kΩ 600 V 600 V • 0,1 A 1000 A 12 Segm. • 20 min 1 ms • 4 kΩ 1000 V 1000 V • 0,1 A 1000 A • • • 40 MΩ 600 V 600 V 400 A 0,01 A 400 A CT-30 12 Segm. • 20 min 1 ms • 4 kΩ 1000 V 1000 V A-300 AC A-400 0-99,9 % 43 Segm. • 20 min 1 ms 200 kHz • 40 MΩ 1000 V 1000 V • • 400 A 1000 A 1000 A 30 mA - 30 A 1 mA-200 A 1 mV = 1 A resp. 0,01 A 10 mV = 1 A 1 mV = 1 A 1 mA /1 mV 1 mV = 1 A A-1000 Transducer 1000 A 1000 A 1000 A 30 mA - 30 A • • • Crestf. > 3:1 Crestf. > 3:1 Crestf. > 3:1 0,01 A 1000 A ACD-51HP ACD-40PQ ACD-55HPQ ACD-41PQ ACD -56 HPQ ACD-330 T ACDC-400 ACDC-620T ACDC-3000 AC/DC 41 Segm. • 30 min • • 400 Ω 400 V 10 μA 100 A DLC-100 Leakage Tester 26 45 26 45 45 45 45 30 50,8 30 50,8 50,8 50,8 23 17 29 30 63x190x32 73x226x32 63x190x32 73x226x32 224x78x40 224x78x40 224x78x40 64x205x39 64x260x39 64x205x39 64x260x32 64x260x32 64x260x32 61x183x36 43x116x23 72x148x36 62x210x36 frequency temperature Non contact Data logger Power Power Power temperature MIN/MAX temperature, back light interface for 3 measuring high capacitance capacitance voltage 5400 points Power factor Power factor Power factor Recording capacitance oscilloscope ranges Resolution detection temp. (31P) Harmonics Harmonics temp. (41PQ) RS-232 Interface • • • Data Logger 5400 points 5400 points (41PQ) Catalogue page number page 19 page 19 page 20 page 20 page 21 page 22 page 23 page 25 page 26 page 21 page 26 page 27 page 27 page 28 page 28 page 28 page 30 Max. jaw opening (mm) Dimension W x H x D Highlights BARGRAPH DATA-HOLD Auto power off • 20 min 600 V Duty Cycle only 0,1 A 1000 A ACD-6Pro ACD-10 Pro TRMS ACD-6 Pro TRMS V~ True RMS only 0,01 A Resolution A= 400 A ACD-10 Pro A~ Measuring functions AC ACD-30P ACD-15 Pro ACD-16 PRO ACD-31P Overview Digital Clamp-Ons ACD-6 Pro 1000 A Digital Clamp-Ons Simple to operate and well-suited for most basic applications. The TRMS version improves performance and reliability. • Large, easy to read LCD display • Auto and manual ranging • Relative zero mode • Auto power off • Diode Test • Data hold • Audible continuity • TRMS Measurement (ACD-6 Pro only) • Accommodates conductors up to 1.77” (45 mm) in diameter • Safety CAT III 600 V Digital Clamp-Ons 333 Function AC Current DC Voltage AC Voltage Resistance ACD-6 Pro ACD-6 TRMS Pro Range Resolution Accuracy 50/60 Hz 400.0 A … 1000 A 0,1 A … 1 A ± (1,5 % rdg + 5 digits) 400.0 mV...400.0 V... 600 V 0,1 mV … 1 V ± (1,7 % rdg + 3 digits) @ 4 V to 400 V ranges 4.000 V...400.0 V...600 V 0,001 V … 1 V ± (2,0 % rdg + 3 digits) @ 4 V to 400 V ranges 400.0 Ω … 40.00 MΩ 0,1 Ω … 0,01 MΩ ± (1,0 % rdg + 4 digits) @ 400 to 400 kΩ ranges Input Impedance: 10 MΩ Continuity check Buzzer is active if Diode Diode test resistance ≤ 120 Ω Test voltage: < 1,6 V Overload protection 600 V DC/AC RMS < 30 s General Data Weight: 190 g, L x W x D: 226 x 73 x 32 mm, max. conductor diameter 45 mm Standard Accessories incl. battery, test leads MTL-90 B, protective case SV-U and manual ACD-10 Pro The Small Allrounder Very handy digital Clamp-On for direct AC current measurement up to 400 A with various Multimeter functions. • Big 3 3/4 LCD display, 3999 digits • AC and DC Voltage up to 600 V • Resistance up to 40 MΩ • Capacitance and frequency measurement • Diode check • Data Hold and Max. function • Audible continuity check Function A Current DC Voltage Input Impendance: 10 MΩ AC Voltage Resistance ACD-10 Pro ACD-10 TRMS Pro Frequency Capacitance Continuity check Diode check Overload protection General Data Standard Accessories • Auto ranging • Auto power off • Low battery indication • Rubber over-molded case • Safety CAT II 600 V, CAT III 300 V Range Resolutions 40,00 A, 400,0 A 0,01 A, 0,1 A 600 A 1A 400 mV 0,1 mV 4 V, 40 V, 400 V 0,001 V, 0,01 V, 0,1V 600 V 1V 4 V, 40 V, 400 V 0,001 V, 0,01V, 0,1 V 600 V* 1V Input Impendance: 10 MΩ, Frequency: 50 ÷ 500 Hz 0 - 400,0 Ω 0,1 Ω 4,000 kΩ, 40,00 kΩ, 400,0 kΩ 1 Ω, 10 Ω, 100 Ω 4,000 MΩ 1 kΩ 40,00 MΩ 10 kΩ 10 Hz - 100 kHz 500.0 nF - 3000 μF 0,1 nF - 1 μF Buzzer is active if resistance < 120 Ω Accuracy 50/60 Hz 1,9 % + 8 digits not specified 0,3 % + 4 digits 0,5 % + 3 digits 1,0 % + 4 digits 1,5 % + 5 digits 2,0 % + 5 digits 0,8 % + 6 digits 0,6 % + 4 digits 1,0 % + 4 digits 2,0 % + 4 digits 0,5 % + 4 digits 3,5 % + 6 digits Diode test voltage: ≤ 1,6 V 600 V DC/AC rms < 30 s Weight: 170 g, W x H x D: 65 x 194 x 30 mm, max. conductor diameter 26 mm incl. 3 V battery, test leads MTL-90 B, protective case SV-U and manual 19 ACD-14 Digital Clamp-On 400 A with Dual Display • 2 x 3 3/4 LCD display 4000 digits • AC + DC Volts up to 600 V • Resistance up to 40 MΩ • μA AC and μA DC measurement • Capacitance and frequency • Diode check, temperature • Audible continuity check Function AC Current 50/60 Hz DC Volts Input Impedance: 10 MΩ AC Volts (50÷500 Hz) Input Impedance: 10 MΩ Resistance ACD-14 ACD-14 TRMS Temperature μA AC and μA DC Frequency Capacitance Continuity check Diode check General Data Standard Accessories • DATA-HOLD and MAX-Function (> 25 ms) • Auto power off • Auto ranging • Low battery indicator • Rubber over-molded case • Safety CAT III 600 V Range Accuracy Resolution 40.00 A, 400 A 1,9% + 8 digits 0,01 A, 0,1 A 600 A not specified 1A 400 mV 0,3% + 4 digits 0,1 mV 4 V, 40 V, 400 V 0,5% + 3 digits 0,001 V, 0,01 V, 0,1 V 600 V 1,0% + 4 digits 1V 4 V, 40 V, 400 V 1,5% + 5 digits 0,001 V, 0,01 V, 0,1 V 600 V* 2,0% + 5 digits 1V 0-400,0 Ω 0,8% + 6 digits 0,1 Ω 4.000 kΩ, 40.00 kΩ, 400.0 kΩ 0,6% + 4 digits 1 Ω, 10 Ω, 100 Ω 4.000 MΩ 1,0% + 4 digits 1 kΩ 40.00 MΩ 2,0% + 4 digits 10 kΩ - 20° C – + 300° C 2,0% + 3° C 0,0 μA to 2000 μA 1,5% + 4 digits (with test leads) 10 Hz to 100 kHz 0,5% + 4 digits 500 nF - 3000 μF 3,5% + 6 digits Buzzer is active if resistance < 120 Ω Overload prot.: 600 V Diode test voltage: ≤ 1,6 V DC/AC rms < 30 s Weight: 204 g, W x H x D: 65 x 194 x 30 mm, cable diameter 26 mm incl. 3 V battery, test leads MTL-90B, protective case SV-U, thermocouple TPK 59 ACD-15 Pro 2000 A AC Digital Clamp-On • Large LCD display with backlight • Auto or manual range selection • AC Current up to 2000 A • AC/DC Voltage up to 600 V • Resistance up to 6 MOhm • Frequency • Capacitance • Non-contact method of Voltage testing ACD-15 Pro ACD-15 TRMS Pro 20 Function AC Current AC/DC Voltage Resistance Frequency Capacitance Non-contact method of voltage testing Weight/Dimension Standard Accessories • Data Hold • Diode Test • Audible continuity • Auto Off • Accommodates conductors up to 1.77" (45 mm) in diameter • Safety CAT III 600 V Range Resolution 400.0 A … 2000 A 0,1 A … 1 A 6.000 V … 600 V 1 mV … 1 V 6.000 kΩ … 6.000 MΩ 1 Ω … 0,001 MΩ 10 Hz … 1 kHz 0,01 Hz … 1 MHz 100,0 nF … 2000 μF 0,1 nF … 1 μF 15 V, 40 V - 130 V, 60 V - 210 V, 90 V - 300 V, > 120 V 190 g, W x H x D 73 x 226 x 32 mm incl. batteries, test leads and manual Accuracy ± (1,5 % rdg + 5 digits) ± (2,0 % rdg + 5 digits) ± (1,0 % rdg + 6 digits) ± (0,5 % rdg + 4 digits) ± (3,5 % rdg + 5 digits) ACD-16 PRO · ACD-16 TRMS PRO NEW 333 • TRMS & Backlight Screen (ACD-16 TRMS PRO only) • Measurements: AC/DC Voltage up to 600 V, AC Current up to 1000 A, Resistance, Frequency and Temperature • Data-logging 5400 points • Optional PC interface capability (RS-232 KIT2) Need the perfect tool to troubleshoot a system? The ACD-16’s provide a full range of measurements, enhanced with data logging capabilities, to catch what the eye can’t see. Double the efficiency, with an optional PC interface kit. ACD-16 Pro ACD-16 TRMS Pro Function AC Current DC Voltage AC Voltage Resistance Frequency Temperature Capacitance Overload Protections Power Supply Jaw opening & Conductor diameter Weight Dimension Standard Accessories • Audible continuity • Auto power off • Automatic polarity • Low battery indication • Data hold • Large, easy to read LCD display • Voltage overload protection for all functions up to 600 V AC/DC • Safety CAT III 600V Digital Clamp-Ons 1000 A Data-Logging Clamp-On Multimeters Range Accuracy 40.0 / 400.0 / 1000 A ± (1.0 % Rdg + 5 LSD) @ 50 and 60 Hz 600.0 V ± (0.5 % Rdg + 5 LSD) 600.0 V ± (1.0 % Rdg + 5 LSD) @ 50 / 60 Hz 999.9 Ohms ± (1.0 % Rdg + 6 LSD) 5.00 Hz to 500.0 Hz ± (0.5 % Rdg +4 LSD) -50 °C to 300 °C (-58 °F to 572 °F) ± (2.0 % Rdg + 3°C) ± (2.0 % Rdg + 6° F) 500 nF - 3000 μF 3.5 % rdg + 6 digits ACA Clamp-on jaws: AC 1000 A RMS continuous + & COM terminals (all functions): 600 VDC/VAC RMS standard 1.5 V AAA Size (NEDA 24 A or IEC LR03) battery x 2 45 mm max 224 g approx. L 224 mm x W 78 mm x H 40 mm Test leads (MTL-90B), batteries installed, user's manual, TPK-59 banana plug type-K thermocouple & soft carrying pouch ACDC-400 400 A AC/DC Clamp-On Multimeter Form and function. This versatile Clamp-On instrument incorporates the features desired for testers in its price range. • AC/DC Current up to 400 A • AC/DC Voltage up to 600 V • Resistance measurement • Continuity test • Data Hold • MAX/MIN recording • Relative zero mode • Backlight ACDC-400 • Analog bar graph • Auto or Manual range selection • Low battery indication • Accommodates conductors up to 1.18” (30 mm) in diameter • Inclusive rubber cap to be inserted on clamp jaws Function DC Voltage AC Voltage AC/DC Current Resistance Range 400.0 mV … 600 V 400.0 mV … 600 V 40.00 A … 400.0 A 400.0 Ω … 40.00 MΩ Resolution 0,1 mV … 1 V 0,1 mV … 1 V 0,01 A … 0,1 A 0,1 Ω … 0.01 MΩ Accuracy ± (1,0 % rdg + 2 digits) ± (1,0 % rdg + 3 digits) ± (2 % rdg + 10 digits) @ 50 - 60 Hz ± (1,0 % rdg + 5 digits), ± (3.0 % rdg + 3 digits) Conductor diameter Power supply Safety General Data Standard Accessories 30 mm 2 batteries 1,5 V LR03 AAA CAT III 600 V Weight: 280 g incl. battery, L x W x H: 205 x 64 x 39 mm incl. batteries, test leads, carrying case, manual and rubber cap MTL-CAP 21 ACD-30P 1000 A Clamp-On Power Meter • TRMS sensing • AutoVA - Auto Selection of AC Volts, DC Volts or AC Amps • AC/DC Voltage up to 600 V, AC Current up to 1000 A, Resistance, Frequency • Active (W), Reactive (VAR) & Apparent (VA) Power with dual-display Power Factor readout • Optional PC interface capability • Audible continuity These instruments combine the standard features of professional clamp-on meters, with full Power analyzing capabilities! Measure: Active (W), Reactive (VAR) and Apparent (VA) Powers along with dual display Power Factor readout. Increase measuring efficiency with an optional PC interface kit. ACD-30P Function AC Current DC Voltage AC Voltage Resistance Frequency Active Power (W) Reactive Power (VAR) Apparent Power (VA) Power Factor Safety Overload Protections Power Supply Dimension Weight Jaw opening Standard Accessories • Auto power off • Automatic polarity • Low battery indication • Peak hold • Data hold • Large, easy to read LCD display • Voltage overload protection for all functions up to 600 V AC/DC • Safety CAT III 600 V Range Basic Accuracy 40.0/400.0/1000 A ± (1.0 % Rdg + 5 LSD) 600.0 V ± (0.5 % Rdg + 5 LSD) 600.0 V ± (0.5 % Rdg + 5 LSD) 999.9 Ohms ± (1.0 % Rdg + 6 LSD) 5.00 Hz to 500.0 Hz ± (0.5 % Rdg + 4 LSD) 0 to 600.0 kW ± (2.0 % Rdg + 6 LSD) 0 to 600.0 kVAR ± (2.0 % Rdg + 6 LSD) 0 to 600.0 kVA ± (2.0 % Rdg + 6 LSD) 0.10 to 0.99 ± 3 LSD Meets IEC61010-2-032 (1994), EN61010-2-032(1995), UL3111-2-032(1999) ACA Clamp-on jaws: AC 1000 A rms continuous + & COM terminals (all functions): 600 VDC/VAC RMS standard 1.5 V AAA Size (NEDA 24A or IEC LR03) battery x 2 L 224 mm x W 78 mm x H 40 mm 224 g approx 45 mm max (Conductor diameter) Carrying case, test leads, batteries (installed), and manual ACD-31P 1000 A Clamp-On Power Meter • TRMS sensing • Back light display • AutoVA - Auto Selection of AC Volts, DC Volts or AC Amps • AC/DC Voltage up to 600 V, AC Current up to 1000 A, Resistance, Frequency • Active (W), Reactive (VAR) & Apparent (VA) Power with dual-display Power Factor readout • Temperature These instruments combine the standard features of professional clamp-on meters, with full Power analyzing capabilities! Measure: Active (W), Reactive (VAR) and Apparent (VA) Powers along with dual display Power Factor readout. Increase measuring efficiency with an optional PC interface kit. ACD-31P 22 Function AC Current DC Voltage AC Voltage Resistance Frequency Active Power (W) Reactive Power (VAR) Apparent Power (VA) Power Factor Temperature Safety Overload Protections Power Supply Dimension/Weight Jaw opening Standard Accessories NEW NEW • Optional PC interface capability • Audible continuity • Auto power off • Automatic polarity • Low battery indication • Peak hold • Data hold • Large, easy to read LCD display • Safety CAT III 600V Range Basic Accuracy 40.0/400.0/1000 A ± (1.0 % Rdg + 5 LSD) 600.0 V ± (0.5 % Rdg + 5 LSD) 600.0 V ± (0.5 % Rdg + 5 LSD) 999.9 Ohms ± (1.0 % Rdg + 6 LSD) 5.00 Hz to 500.0 Hz ± (0.5 % Rdg + 4 LSD) 0 to 600.0 kW ± (2.0 % Rdg + 6 LSD) Fund to 10th & PF > 0.7 0 to 600.0 kVAR ± (2.0 % Rdg + 6 LSD) Fund to 10th & PF > 0.7 0 to 600.0 kVA ± (2.0 % Rdg + 6 LSD) Fund to 10th 0.10 to 0.99 ± 3 LSD -50 °C to 300 °C (-58 °F to 572 °F) ± (2.0 % Rdg + 3°C) ± (2.0 % Rdg + 6°F) Meets IEC61010-2-032 (1994), EN61010-2-032(1995), UL3111-2-032(1999). ACA Clamp-on jaws: AC 1000 A rms continuous + & COM terminals (all functions): 600 VDC/VAC RMS standard 1.5 V AAA Size (NEDA 24 A or IEC LR03) battery x 2 L 224 mm x W 78 mm x H 40 mm/224 g approx 45 mm max (Conductor diameter) Carrying case, test leads, batteries (installed), thermocouple and manual ACD-40PQ NEW 333 • TRMS sensing • Total Harmonics Distortion THD, AC/DC Voltage up to 600 V, AC Current up to 1000 A, Resistance, Frequency, Temperature • Data-logging 5400 points • Optional PC interface capability • Audible continuity The ACD-40’s provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. ACD-40PQ • Auto power off • Automatic polarity • Low battery indication • Data hold • Large, easy to read LCD display with backlight • Safety CAT III 600V Digital Clamp-Ons 1000 A Data-logging Clamp-On with THD Measurement Function AC Current DC Voltage AC Voltage Resistance Frequency THD-R * Temperature Hi-Lo Logging Safety Overload Protections Range Basic Accuracy 40.0 / 400.0 / 1000 A ± (1.0 % Rdg + 5 LSD) 600.0 V ± (0.5 % Rdg + 5 LSD) 600.0 V ± (0.5 % Rdg + 5 LSD) 999.9 Ohms ± (1.0 % Rdg + 6 LSD) 5.00 Hz to 500.0 Hz ± (0.5 % Rdg +4 LSD) 0.0 % to 99.9 % 1.5 % of Reading + 6 d @ Fund Frequency -50 °C to 300 °C (-58 °F to 572 °F) ± (2.0 % Rdg + 3°C) ± (2.0% Rdg + 6°F) 5400 Points Meets IEC61010-2-032 (1994), EN61010-2-032(1995), UL3111-2-032(1999) ACA Clamp-on jaws: AC 1000A RMS continuous + & COM terminals (all functions): 600 VDC/VAC RMS Power Supply standard 1.5 V AAA Size (NEDA 24A or IEC LR03) battery x 2 Dimension L 224 mm x W 78 mm x H 40 mm Weight 224 g approx Jaw opening 45 mm max (Conductor diameter) Standard Accessories Carrying case, test leads, batteries (installed), thermocouple and manual included *THD-R is defined as: (Total Harmonic RMS/Total RMS) x 100 % ACD-41PQ NEW 1000 A Power Quality Clamp-On with THD Measurement • TRMS sensing • Total Harmonics Distortion THD, AC/DC Voltage up to 600 V, AC Current up to 1000 A, Resistance, Frequency, Temperature • Active (W), Reactive (VAR) and Apparent (VA), Power with dual-display, Power Factor readout • Auto VA - Auto Selection of AC Volts, DC Volts or AC Amps The ACD-40’s provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. ACD-41PQ • Data-logging 5400 points • Optional PC interface capability • Audible continuity • Auto power off • Automatic polarity • Low battery indication • Peak hold • Data hold • Large, easy to read LCD display with backlight • Safety CAT III 600V Function Range Basic Accuracy AC Current 40.0 / 400.0 / 1000 A ± (1.0 % Rdg + 5 LSD) DC Voltage 600.0 V ± (0.5 % Rdg + 5 LSD) AC Voltage 600.0 V ± (0.5 % Rdg + 5 LSD) Resistance 999.9 Ohms ± (1.0 % Rdg + 6 LSD) Frequency 5.00 Hz to 500.0 Hz ± (0.5 % Rdg + 4 LSD) THD-F * 0.0 % to 99.9 % 1.5 % of Reading + 6d @ Fund Frequency Active Power (W) 0 to 600.0 kW ± (2.0% Rdg + 6 LSD) Reactive Power (VAR) 0 to 600.0 kVAR ± (2.0% Rdg + 6 LSD) Apparent Power (VA) 0 to 600.0 kVA ± (2.0% Rdg + 6 LSD) Power Factor 0.10 to 0.99 ± 3 LSD Temperature -50 °C to 300 °C (-58 °F to 572 °F) ± (2.0 % Rdg + 3°C) ± (2.0 % Rdg + 6°F) Safety Meets IEC61010-2-032 (1994), EN61010-2-032(1995), UL3111-2-032(1999). Overload Protections ACA Clamp-on jaws: AC 1000A RMS continuous + & COM terminals (all functions): 600 VDC/VAC RMS Power Supply standard 1.5 V AAA Size (NEDA 24A or IEC LR03) battery x 2 Dimension/Weight L 224 mm x W 78 mm x H 40 mm/224 g approx Jaw opening 45 mm max (Conductor diameter) Standard Accessories Carrying case, test leads, batteries (installed), thermocouple and manual included *THD-F is defined as: (Total Harmonic RMS/Fundamental RMS) x 100% 23 ACD-50er Series – Power & Power Quality Clamp-Ons Enjoy the versatility of improved technology. Amprobe offers basic power quality capability combined with TRMS Clamp-On ammeter functionality. Thanks to the practical rubber cap to be mounted on the jaws (patented) it's possible to hold test leads while measuring and have one hand free to work. MTL-CAP Rubber cap to insert on clamp jaws. 24 • Accomodates conductors up to 30 mm in diameter • Resistance up to 2000 Ω • TRMS Measurement • Frequency (with test leads and jaw) • AC Current up to 400 A • Phase rotation • AC/DC Voltage up to 600 V • Voltage and Current Harmonics up to 25th with THD% (ACD-55HPQ and ACD-56HPQ only) • Backlight • Data Hold, MAX/MIN/AVG recording • Active, Reactive and Apparent Power, Single/Three Phase (ACD-51HP and ACD-56HPQ only) • Low battery indication • Power Factor, Cos Ø Single/Three Phase/Energy (ACD-51HP and ACD-56HPQ only) • Safety CAT III 600 V • Autoranging • Auto Power OFF ACD-50er Series – Power & Power Quality Clamp-Ons Digital Clamp-Ons 333 ACD-51HP Function DC Voltage AC Voltage TRMS Max. Crest Factor 1.5 MAX/MIN/AVG AC/DC Voltage Response Time 500 ms PEAK AC/DC Voltage Response Time 1 ms AC Current TRMS Max. Crest Factor 2 MAX/MIN/AVG AC Current Response Time 500 ms PEAK AC Current Response Time 15 ms Resistance and Continuity Test Instrument emitted a buzzer for R< 40 Ω Frequency (with test leads) Voltage Range: 0.5 - 600 V Frequency (with jaws) Voltage Range: 0.5 - 400 V Active/Reactive/Apparent Power [kW]/[kVAR]/[kVA] (ACD-51HP and ACD-56HPQ only) Power factor Min Current 2 A (ACD-51HPQ and ACD-56HPQ only) ACD-55HPQ ACD-56HPQ Range 1,6 V … 599,9 V 1,6 V … 599,9 V Resolution 0,1 V 0,1 V 10 V … 599,9 V 0,1 V Accuracy ± (1 % rdg + 3 digits) 40 - 200 Hz ± (1 % rdg + 3 digits) 200 - 400 Hz ± (5 % rdg + 3 digits) ± (5.0 % rdg + 10 digits) Overload Protection 10 V … 850 V 1V ± (5.0 % rdg + 3 digits) 0,0 A … 399,9 A 0,1 A 600 A RMS 1,0 A … 399,9 A 0,1 A 40 - 200 Hz ± (1 % rdg + 3 digits) 200 - 400 Hz ± (5 % rdg + 5 digits) ± (5.0 % rdg + 10 digits) 10 A … 800 A 1A ± (5.0 % rdg + 10 digits) 600 A RMS 0,0 Ω … 1999 Ω 0,1 Ω…3 Ω ± (1.0 % rdg + 5 digits) 600 V AC/DC RMS 40 Hz … 399,9 Hz 0,1 Hz ± (0.5 % rdg + 1 digits) 600 V RMS 40 Hz … 399,9 Hz 0,1 Hz ± (0.5 % rdg + 1 digits) 600 A RMS 0,00 … 999,99 0,01 … 0,1 ± (3.5 % rdg + 3 digits) sine wave, voltage 100 ÷ 600 V, current 1 A, freq. 50 - 60 Hz, Pf: 0.8 i ÷ 0.8 c 0,20 … 100 0,01 ±3° Voltage and current harmonics (only ACD-55HPQ and ACD-56HPQ) Harmonic order 1 … 15 16 … 25 Resolution [V]/[A]/% Accuracy 0,1 ± (10.0 % rdg + 5 digits) 0,1 ± (15.0 % rdg + 5 digits) voltage 1.6 V, current 2 A Input Impedance Display Operating Temperature Max. cable diameter Power Supply General Data Standard Assessories 1 MΩ 4 digits LCD with maximum reading 9999 units plus decimal point and sign 64 samples in 20 ms 5 - 40° C/< 80 % RH 30 mm 2 batteries 1,5 V LR03 AAA Weight: 280 g incl. batteries, L x W x D: 205 x 64 x 39 mm Test leads, carrying case, rubber cap, alligator clips, user manual 600 A RMS 25 ACD-330 T 1000 A AC True RMS Clamp-On True RMS Clamp-On for sinusoidal or high distorted signals. • LCD display Digits 4.000 • Analog bar graph 12 Segment • MAX, MIN, DATA-HOLD • Max cable diameter 50,8 mm • DATA-HOLD & PEAK HOLD 1 ms Function DC Voltage AC Voltage AC Current ACD-330 T Resistance Diode test Crest Factor Dimension Operating Temperature Weight Power supply Standard Accessories • AC/DC Voltage up to 1000 V • Diode + audible continuity check • Auto ranging • Auto power off • Safety CAT III 600 V Range Resolution Accuracy 0 … 400 … 1000 V 0,1 V … 1 V ± 1,0 % ± 3 digits 0 … 400 … 1000 V 0,1 V … 1 V ± 1,5 % ± 3 digits 0,00 … 400,0 0,01 A … 0,1 A … 1 A ± 1,5 % ± 3 digits … 700 A … 1000 A 1A ± 3,5 % ± 5 digits 0 … 400 … 4 kOhm 0,1 … 1 Ohm 1,0 % ± 3 digits 0…2V 1 mV 1,0 % ± 3 digits < 3:1 W x H x D 64 x 260 x 32 mm 0 - 50° C/< 80 % R.H. 840 g 1 alkaline 9 V battery IEC6F22 incl. 9 V battery, test leads DTL-3000 and carrying case CC-ACDC ACDC-620 T 1000 A AC/DC True RMS-Clamp-On with Temperature Measurement True RMS Clamp-On for sinusoidal or high distorted signals. • LCD display Digits 4.000 • Analog bar graph 12 Segment • MAX, MIN, DATA-HOLD • incl. K-Type Temperature measurement • automatic DC adjustment • Max cable diameter 50,8 mm • DATA HOLD & PEAK HOLD 1 ms • AC + DC Voltage up to 1000 V • AC/DC Current up to 1000 A • Diode and audible continuity check • Capacity Range • Auto/Manual Ranging • Auto power off • Safety CAT III 600 V Function AC Voltage AC & DC Current ACDC-620 T Option: Temperature measurement TAC-DMM DKTA-620 TPK-56 26 Range Resolution Accuracy 0 … 400 … 1000 V 0,1 V ... 1V ± 1,5 % ± 3 digits 0,0 … 399,9 … 0,1 A ... 0,1 A DC: ± 1,5 % ± 3 digits /AC: ± 2.0 % ± 5 digits 400 … 1000 A 1A DC: ± 2.0 % ± 5 digits /AC: ± 2.5 % ± 5 digits Resistance 0 … 400… 4 kOhm 0,1 ...1 Ohm 1,0 % ± 3 digits Diode test 0…2V 1 mV 1,0 % ± 3 digits Capacity 0…40 uF…400 uF…4000 uF 0,01…0,1…1 uF 3,0 % ± 4 digits Crest Factor < 3:1 Dimension W x H x D 64 x 260 x 32 mm Operating Temperature 0 - 50° C/< 80 % R.H. Weight 840 g Power supply 1 alkaline 9 V battery IEC6F22 Standard Accessories incl. 9 V battery, test leads DTL-3000 and carrying case CC-ACDC Accessories on page 106 ACDC-3000 333 TRMS-Power Analysis Clamp-On with Multimeter Function for sinusoidal or high distorted signals. • LCD display Digits 4.000 - 20.000 • Analog bar graph 43 Segment • MAX, MIN, DATA-HOLD • LCD Back light • automatic DC adjustment • Max cable diameter 50,8 mm • DATA HOLD & PEAK HOLD 1 ms ACDC-3000 Function DC Voltage AC Voltage AC Current, DC Current & (AC+DC) Resistance Diode test Capacity Crest Factor Frequency Dimension/Weight Operating Temperature Power supply Standard Accessories • AC + DC Voltage up to 1000 V • AC + DC Current up to 1000 A • Diode and audible continuity test • Capacity and Frequency Range up to 200 kHz • Auto ranging • Auto power off • Safety CAT III 600 V Digital Clamp-Ons 1000 A AC + DC TRMS-Measurement for Power Analysis Range Resolution Accuracy 0 … 400 … 1000 V 0,1 V … 1 V ± 1,0 % ± 3 digits 0 … 400 … 1000 V 0,1 V … 1 V ± 1,5 % ± 3 digits 0,00 … 39,99… 0,01 A DC: ± 2 % ± 30 digits, AC: ± 2 % ± 10 digits, … 399,9 A … 0,1 A DC: ± 1,5 % ± 3 digits, AC: ± 2 % ± 5 digits … 1000 A 1A DC: ± 2 % ± 5 digits, AC: ± 2,5 % ± 5 digits 0,1 … 400 … 4 MOhm 0,1 ...1...10 KOhm 1,0 % ± 3 digits 0…2V 1 mV 1,0 % ± 3 digits 0...40 uF...400 uF...4000 uF 0,01...0,1...1uF 3,0 % ± 4 digits < 3:1 0.. 200... 200 KHz 0,01...0,1...100Hz 0,2 % ± 4 digits W x H x D 64 x 260 x 32 mm/840 g 0 - 50° C/< 80 % R.H. 1 alkaline 9 V battery IEC6F22 incl. 9 V battery, test leads DTL-3000 and carrying case CC-ACDC A-1000 1000 A AC/DC True RMS-digital Camp-On with analog output • AC- and DC Current up to 1000 A • For use with multimeters or any instrument with DC mV input • adjustable output functions with mode switch DC or AC Function DC Current The AMPROBE A-1000 enables the normal ”meanvalue-measuring” digital multimeter to measure the true RMS value – and it’s able to render the curve on an oscilloscope. A-1000 Range • connection to digital multimeter or oscilloscope resp. linerecorder • Power on and low battery indicator • Max cable diameter 50,8 mm • Safety CAT III 600 V Resolution/ output signal 1 mV / 1 A Accuracy 0 … 99,99 A ± 1,5 % + 0,3 A 100 … 1000 A ±2%+1A AC Current 0 … 99,99 A 1 mV/ 1 A ± 1,5 % ± 0,5 A 100 … 1000 A AC or DC selectable ±2%+1A Crest Factor < 3:1 max. Input impedance 30 kOhm Dimension W x H x D 64 x 260 x 32 mm Operating Temperature 0 - 50° C/< 80 % R.H. Weight 840 g Power supply 1 alkaline 9 V battery IEC6F22 Standard Accessories incl. 9 V battery, test leads DTL-1000, BNC-access line DTL-ABNC and carrying case CC-ACDC 27 A-300 Mini Transducer Clamp-On from 1 mA up to 200 A AC • for every multimeter with AC Volts input • Leakage current measurement without opening the cable • 3 measuring ranges 1 A/ 10 A /200 A AC • max conductor diameter 15 mm A-300 Adapter for connection to Skylab and Energytest ACF-6 A Range 1 mA … 1 A AC 1 A … 10 A AC 10 A … 200 A AC Weight Dimension W x H x D Standard Accessories Output voltage Frequency range 1 mV/1 mA 40 - 60 Hz 100 mV/1 A 40 - 5000 Hz 5 mV/1 A 40 - 5000 Hz 165 g 43 x 116 x 23 mm, Inside: 15 x 17 mm incl. test leads with banana plug sockets Accuracy ± 2 % from 0,1 In to 1,2 In max. 3 % of measured value A-400 AC Current Transducer Clamp-On Secure Measurement of High AC Currents with every Multimeter • Measuring range from 0,1 A up to 400 A AC • Max. jaw opening 30 mm • For use with any multimeter with AC mV input A-400 Range 0,1 A AC to 400 A AC/50 - 60 Hz Accuracy 1,9 % Output voltage 1 mV/1A max. output resistance 75 Ω Frequency range 50 - 60 Hz max. jaw opening 30 mm Weight 250 g Dimension W x H x D 72 x 148 x 36 mm Voltage save up to 600 V according to IEC 1010-1 CT-30 Transducer Clamp-On for AC and DC residual current The transducer Clamp-Ons extend the abilities of your multimeter to measure AC current from 1 mA up to 400 A contact-less. • for AC currents from 3 mA up to 30 A • Low battery indicator • for DC currents from 0,3 A up to 30 A • Auto Zero function eleminates residual magnetism • Voltage output in mV AC or DC CT-30 • max. conductor diameter 23 mm Range DC 400 mA DC 4 A AC 400 mA AC 4 A AC 30 A Dimension W x H x D Weight Power supply Standard Accessories 28 Output Accuracy DC 1 mV/mA not specified DC 100 mV/A ± 2 % ± 30 mA AC 1 mV/1 mA ± 2 % ± 0,5 mA AC 100 mV/A ± 2,5 % ± 5 mA AC 10 mV/A ± 2 % ± 30 mA 61,3 x 183 x 35,6 mm 190 g incl. batteries 2 x 1,5 V AA batteries, current drain appr. 10 mA incl. batteries, protective case and test leads ACF-3000-AK 333 Qualified for every digital multimeter with AC voltage input. • Safety: IEC 1010, CAT III 600 V • 2 m connecting cable ACF-3000-AK Range Output Frequency range Accuracy Weight Conductor diameter Inside diameter-Ø Dimension/Diameter Standard Accessories Battery life time 30 A / 300 A / 3000 A 100 mV / 10 mV / 1 mV per A (max. 3 V) 10 Hz up to 20 kHz ± 1 % of particular measuring range 180 g 14,3 mm 178 mm 610 mm length (open)/Ø 14,3 mm incl. 2 x 1,5 V AA batteries appr. 200 h Digital Clamp-Ons Flexible Current Transducer up to 3000 A AC ACF-3003 3-Phase AC Current Transducer up to 3000 A AC Long time measurements (e.g. with the 3 phase power and harmonic analyser DM-IV or ENERGYTEST 2020 E) are possible as a result of the long battery life time of 1000 h. • Safety: IEC 1010-1, CAT III 600 V • 2 m connecting cable ACF-3003 Range Output Frequency range Accuracy Weight Connection cable Inside diameter Dimension/Diameter Standard Accessories Battery life time 300 A + 3000 A AC 0,33 mV per 1 A /3,3 mV per 1 A (max. 1 V output) 10 Hz - 5 kHz ± 1,0 % 190 g case with electronics, 180 g each flex. transducer 2m 190 mm 600 mm length (open) / Ø 14,3 mm incl. 2 x 1,5 V batteries > 1000 h ACF-3000 DM-A · ACF-3000 SR Flexible AC Current Transducer up to 3000 A AC Long time measurements (e.g. with the 3 phase power and harmonic analyser SKYLAB or ENERGYTEST 2020 E) are possible as a result of the long battery life time of 3000 h. • Safety: IEC 1010, CAT III 600 V ACF-3000 DM-A ACF-3000 SR Power supply APS 1012 Model Range Output Frequency Range Accuracy Weight Conductor diameter Inside diameter Dimension/Diameter Standard Accessories Battery life time Suitable for ACF-3000 DM-A ACF-3000 SR 300 A / 3000 A 15 - 3000 A 1 mV / 0,1 mV per A 0,33 mV/per A (max 1 V) 10 Hz - 5 kHz 10 Hz - 5 kHz ± 1% 180 g 14,3 mm 178 mm 610 mm length (open)/Ø 14,3 mm incl. 2 x 1,5 V mignon batteries and adapter ACF-5ACE > 3000 h DM-II DM-IV, ENERGYTEST 2020 E 29 DLC-100 Low Current, AC Clamp-On Multimeter Leakage currents at μA range can be found fast, safe and accurate with DLC-100, the perfect instrument for locating possible sources of error, e.g. insulation errors to avoid consequential damage of running systems. • Resolution to 10 μA • AC current from 0,05 mA to 100 A • AC volts to 400 V AC • Resistance to 400 Ω • Continuity Buzzer • High resolution 3 3/4 LCD display with bar graph • MAX/MIN function • Max. conductor diameter 30 mm DLC-100 Range 0 - 40 mA 0 - 400 mA 0-4A 0 - 40 A 0 - 80 A 80 - 100 A Voltage 0 - 400 V Resistance (10 MΩ, Input impedance) 0 - 400 Ω Overload protection Dimension W x H x D Weight Power supply Standard Accessories 30 Resolution 10 μA 100 μA 1 mA 10 mA 100 mA 100 mA Accuracy (50 Hz) ± 1,0 % ± 3 digits ± 1,0 % ± 3 digits ± 1,0 % ± 3 digits ± 1,0 % ± 3 digits ± 2,5 % ± 10 digits ± 9,0 % ± 10 digits 0,1 V ± 1,0 % ± 3 digits 0,1 Ω ±1,0 % ± 3 digits (Buzzer sounds at valutes < 38 Ω) 800 V AC at voltage range, 600 V AC (1 min) at resistance range 62 x 210 x 35,6 mm 200 g incl. batteries 2 x 1,5 Volt AA batteries, current drain appr. 10 mA incl. batteries, carrying case test leads DTL-10 31 VDE Test Instruments Electrical Safety Regulations Electrical Installations Electrical Installations Appliance testing Machines IEC 60364-6-61 DIN VDE 0100 Part 610 EN50110-1 DIN VDE 0105 Part 1/100 DIN VDE 0701/0702 Part 1 IEC 60204, EN 60204 DIN VDE 0113 Electrical installations of buildings, initial verification Operating of electrical installations Repair, modification and inspection of electrical appliances Safety of machines Repeat tests on electrical appliances GSC-53 GENIUS 5035 GENIUS 5080 E COMBITEST 2019 ISOTEST 2010 SPEEDTEST 2018 GEOTEST 2016 32 GSC-53 GENIUS 5035 GENIUS 5080 E COMBITEST 2019 ISOTEST 2010 SPEEDTEST 2018 GEOTEST 2016 ULTRA 0701/0702 S AUTOTEST 0701/2 PAT TESTER 0701/2 Powertest 0701/2 e-tester 0701 0702 Electrical equipment of machines SAFETEST ALLTEST 33 Catalogue page RS232-PC interface Dimension W x H x D Weight Standard Accessories Memory Limit value Remoteable Maloperation protection Power measurement Withstanding Leakage current Insulation resistance Loop impendance Low-Ohms RCD test with and without tripping Tripping time Release current la Earth resistance Phase sequencing Voltage Frequency Contiunity check 10 A Touch/leakage current VDE 0113 EN 60204-1 VDE 0113 EN 60204-1 0413 part 5 0413 part 7 yes yes 1 + 3 Phasen yes 0 - 4,000 Ω 0 - 40,0 mA 0 - 20,00 MΩ 0 - 4,000 mA 500 V 1000 V 0 - 40,0 mA Powertest 0701/2S 0 - 4,000 Ω 0 - 20,00 MΩ 0 - 2 GΩ 0 - 2 kΩ 0 - 99,9 Ω yes yes yes 0 - 2 kΩ yes 0 - 500 V 14 - 500 Hz yes yes 0 - 2 kΩ yes 0 - 500 V 14 - 500 Hz GSC-53 A GENIUS 80 E yes yes 50 V - 100 V 250 V - 500 V1000 V 0 - 2 GΩ 0 - 2 kΩ 0 - 99,9 Ω yes 50 V - 100 V 250 V - 500 V1000 V GENIUS 5035 yes yes 0 - 440 V 15,3 - 100 Hz yes yes 0 -1999 MΩ 0 - 2 kΩ 0 - 20 Ω yes yes 0 - 440 V 15,3 - 100 Hz yes yes yes 0 - 2 kΩ COMBITEST 2019 SPEEDTEST 2018 yes yes 50 V - 100 V 250 V - 500 V1000 V 0 - 600 V 0 - 4000 Ω 0 - 4000 MΩ 250 V - 500 V1000 V VDE 0100 MEGATEST-1 yes yes 1000 600 values 600 values 350 350 4000 yes yes yes yes yes yes yes yes yes 1 + 3 phase 1 phase (Genius 80 E) up to 25 kW 3 phase (GSC-53) yes yes yes + software + software yes yes yes 100 x 40 x 195 170 x 180 x 60 530 x 330 x 230 165 x 225 x 105 165 x 225 x 105 162 x 222 x 57 162 x 222 x 57 116 x 320 x 62 575 g 1,1 kg 7 kg 1,5 kg 1,5 kg 1000 g 1000 g 750 g Test leads case, test lead set, case, test lead set, case, test lead set, case, test lead set, case, test lead set, case, test lead set, case, test lead set, RS-232 cable software, memory rubber holster, rubber holster, software, memory, software, memory, software, memory, software software software RS-232 cable RS-232 cable RS-232 cable page 38 page 40 page 46 page 50 page 51 page 55 page 56 page 60 800 values yes yes 0 - 1000 mΩ 0 - 19,99 Ω LED 0 - 10 mA 0,2 - 10,0 MΩ 0 - 10 mA 0 - 20 MΩ 0 - 4,00 mA 0 - 20,0 mA Subtitute leakage current 0 - 20,0 mA 500 V 500 V 0701 part 1 0702 0701 0702 0702 0413 part 2 0413 part 3 0413 part 4 0413 part 6 0701/0702 AUTOTEST 0 - 1000 mΩ 0,2 - 10 MΩ ULTRA 701/702S 0 - 19,99 Ω 20 MΩ VDE Regulation 0701 part 1 0701 part 1 Test function Ground resistance Insulation resistance Test voltage at insulation (DC) Overview VDE Test Instruments 10/25 A 0 - 1 kV (500 VA) 350 yes yes yes 0 - 440 V 0 - 50 mA 0 - 100 MΩ 500 V 700 yes yes yes 0 - 100 MΩ 500 V VDE 0113 ALLTEST SAFETEST 0 - 1,999 Ω 0 - 1,999 Ω yes + software + software 162 x 222 x 57 400 x 290 x 130 360 x 270 x 160 1000 g 12 kg 8 kg case, test lead set, HV - pistol, test leads, software, memory, test leads, software RS-232 cable software page 57 page 63 page 62 yes 10/25 A 0 - 4 kV (500 VA) 350 0 - 440 V 0 - 2 kΩ GEOTEST 2016 VDE Test Instruments yes 162 x 222 x 57 1000 g case, test lead set, software, memory, RS-232 cable page 56 yes 4000 yes 0 - 20 Ω 0 - 1999 MΩ Insulationtester 2010 yes yes 50 V - 100 V 250 V - 500 V1000 V Electrical Installation Testing, Portable Appliance Testing and checking other non-electrical apparatus requires the taking of many measurements, documenting results and the issuing of certificates; a time consuming exercise. e-manager for Windows is a modular suite of software. It accepts data direct from almost any downloading instrument, regardless of manufacturer, e.g. Amprobe, ABB, Beha, Chauvin Arnoux, Gossen-Metrawatt and LEM. One software for all • Certification for Portable Appliance Testing • Certification for BS7671 2001 Installation • Certification for non- electrical assets • Accepts test results from any downloading instrument or manual entry • Organiser, Reports and optional modules available Order a Free Demo CD NOW. Your Advantages • One Software for all commonly available instruments • Fast and easy creation of all test protocols • No lost data when changing the test instrument • Data exchange from or to the test instrument • Export to Facility-Management-Software • Optional Bar Code and transponder identification • Barcode- und transponderkompatibel • Very Fast and Easy to learn and to use • Maintenance of facility-, machine-, instrument- and customer data 34 VDE Test Instruments Professional Test and Protocol Software Screenshot „e-manager - Software“ System requirements • MS Windows 98 /2000/XP/NT 4.0 SP 5.0 • 16 MB RAM Data Interfaces • Interfaces to all common Facility Management-Programs and Applications (e.g. ADMETOS, Metcs, MT-Data) Technical Advantages • Latest 32 bit-Software for Windows 98/2000/XP • Future-proof by object-oriented Programming in C++ • Easy and clearly data backup and management • Multi-User and Network ability More Possibilities • Individual forms for reports and test protocols with your own company logo • Every manageable instrument can be accessed by special device drivers (Add-In-Technology) e-manager pro Software incl. two Add-Ins Designmanager 35 Workshop Kit WEP-IIM Non-Contact Volt Probe VOLT PROBE VP 440 Uses non-contact method of Voltage testing, range: 110 - 440 Volt AC No disconnecting of electrical system necessary. Volt and Current Measuring AC and DC up to 600 V and 15 A: AM-100 Rugged Digital Multimeter with Large Easy to READ LCD-Display, Voltage and Current Measurement Resistance up to 40 MOhm Audible Continuity and Diode Test DIN VDE 0411 Digital Clamp-On Multimeter up to 200 A: ACD-10 Pro Mini-Clamp-On up to 400 A AC, 600 V AC/DC, 40 MΩ, Auto off, Data Hold, audible continuity check, max conductor diameter up to 26 mm, rubber over-molded case, inclusive carrying case. VDE 0701/0702 and VBG 4 Portable Appliance Tester ULTRA 0701/0702 S Touch leakage current, substiture leakage current, earth bond resistance, insulation and protective conductor resistance, clear indication by exceeding limit valures via LED's, inclusive RS232 interface, optional: Software VDE 0100/VBG 4 Multifunction installation tester, VDE 0413 (16th Edition) Genius 35 Universal testing instrument, insulation resistance, line and fault loop impedance, continuity test of earth, protective and equalizing potential conductors, RCD-Test, Phase rotation incl. interface cable, memory, software, test leads and rubber over-molded case, optional: earth cable set 36 Non-Contact Volt Probe VOLT PROBE VP 440 Uses non-contact method of Voltage testing, range: 110 - 440 Volt AC No disconnecting of electrical system necessary. Volt and Current Measuring AC and DC up to 600 V and 15 A: VDE Test Instruments Workshop Kit WEP-5P AM-100 Rugged Digital Multimeter with Large Easy to READ LCD-Display, Voltage and Current Measurement Resistance up to 40 MOhm Audible Continuity and Diode Test DIN VDE 0411 Digital Clamp-On Multimeter up to 200 A: ACD-10 Pro Mini-Clamp-on up to 400 A AC, 600 V AC/DC, 40 MΩ, Auto off, Data Hold, audible continuity check, max conductor diameter up to 26 mm, rubber over-molded case, inclusive carrying case. VDE 0701/0702 and BGV A3 Portable Appliance Tester Autotest 0701/0702 S Touch Leakage Current, Auxiliary Leakage Current, Earth Bond Resistance, Insulation and Protective Conductor Resistance, Selectable Automatic and Manual Test Procedure, Inclusive RS-232 Interface Memory and Software VDE 0100 and BGV A3 Multifunction installation tester, VDE 0413 (16th Edition) Genius 35 Universal testing instrument, insulation resistance, line and fault loop impedance, continuity test of earth, protective and equalizing potential conductors, RCD-Test, Phase rotation incl. interface cable, memory, software, test leads and rubber over-molded case, optional: earth cable set 37 ULTRA 0701/0702S The Test Instrument Portable Appliance Tester VDE 0701/0702 and BGV A2 • LED display for limit values • incl. RS-232 interface • high accuracy • small, lightweight, easy manual operation • GS approved Since the introduction of VDE standards 0701/0702, the compliance with the limits set out therein must be evidenced for all repaired or modified electrical appliances rated safety class I, II or III. For this, AMPROBE developed its class 2.5% ULTRA 0701/0702s wich allows for determining whether the following limits stipulated in standards VDE 0701, 0702 and VBG4 are met: • Protective conductor resistance • Insulation resistance • Substitute leakage current • Leakage Current • Touch leakage current The perfect test instrument for handcraft, trade and industry in the domains of household appliances, IT and copiying for service, repair and maintenance. Because of the display of limit values (3 red LED), the ULTRA 0701/0702 S is also appropriate for instructed persons. Interface and software allow a print-out of the measured values as a test log. Function Protective conductor resistance Insulation resistance Substitute leakage current Earth bond current Touch leakage current Contact voltage Display Dimension W x H x D Weight RS-232 Interface Power supply Standard Accessories Range Accuracy Open-circuit voltage Max. short-circuit current 0 - 19,99 Ω 2,5 % ± 2 digits 20 V AC max. 350 mA 0 - 19,99 MΩ 2,5 % ± 2 digits 650 V DC max. 3,5 mA 0 - 19,99 mA 2,5 % ± 2 digits 40 V AC max. 2 mA 0 - 4,00 mA AC/DC 2,5 % ± 2 digits Ri = 2 kΩ 0 - 4,00 mA AC/DC 2,5 % ± 2 digits Ri = 2 kΩ 0 - 4,00 mA AC/DC 2,5 % ± 2 digits Ri = 2 kΩ LCD-Display fast PLL controlled with 3 LED for limit value 100 x 195 x 40 mm 500 g (without leads) Seriell, Format: 2400 N, 8, 1 Connector: 2-channel jack bush 3,5 mm Mains supply 230 V AC/50 Hz, consumption: 10 VA, attached to the instrument: Line-cord with shuko-bush for test instrument connection 1 Set test leads with probe, leads with allicator clips for measuring the protective conductor resistance, detailed manual Ultra 0701/0702 S Carrying case B41 DAK-16 Three phase adapter DAK-16 Three phase adapter DAK-32 38 Barcode-Scanner USB Software 0701/2 S TLP-701 Test lead set for DAK and Ultra 0701/2S Barcode-Printer Barcode-Scanner PS/2 for PC incl. Interface Cable The leakage current adapter ist necessary for measuring the earth leakage current based on VDE 0701/0702 in combination with the ULTRA 0701/0702S. ABA-1 ABA-1 FI Leakage current adapter with residual current protect switch VDE Test Instruments ABA-1 Leakage Current Adapter DSA-3 3 phase leakage current adapter ABA-1 and ABA-1FI ULTRA 0751 For measurement of portable instruments incl. electro-medical instruments VDE 0701, VDE 0702, VDE 0751 With the Ultra 0751 you have the possibility to perform following measurements, to check the abidance of the limit values: • Earth bond resistance • Insulation resistance • Substitute leakage current • Touch leakage current • Earth leakage current Special Features: • Fast PLL controlled LCD display • RS-232 interface for PC • Display of limit values (3 red LED) • Very small and lightweight • Quality made in Germany Function Earth bond resistance Insulation resistance Substitute leakage current Earth leakage current Display Dimension W x H x D Weight RS-232 Interface Power supply Standard Accessories Range Accuracy Open-circuit voltage 0,00 - 19,99 Ω 2,5 % ± 2 digits 20 V AC max. 0 - 19,99 MΩ 2,5 % ± 2 digits 650 V DC max. 0,00 - 19,99 mA 2,5 % ± 2 digits 230 V AC max. 0,000 - 1,999 mA 2,5 % ± 2 digits Ri = 1 kΩ 2,00 - 19,99 mA LCD-Display fast PLL controlled with 3 LED for display off limit values 100 x 195 x 40 mm 500 g (without leads) Serial, Format: 2400 N, 8, 1 Connector: 2-channel jack bush 3,5 mm Mains supply 230 V AC/50 Hz, consumption: 10 VA attached to the instrument: Line-cord with Shuko connector for test instrument connection 1 set test leads with probe, leads with alligator clipps for measuring the protective condutor resistance, rubber over-molded case, detailed manual Ultra 0751 Software Ultra 0751 39 AUTOTEST 0701/2 S PAT Instrument Portable Appliance Tester according to DIN VDE 0701, DIN VDE 0702 and BGV A3 (BGV A2). • Automatic or manual testing process • Confortable operation by dialog promting on LCD display • Memory for max. 800 values • Automatic power plug pole reversal • Differential current measuring procedure • RS 232 C interface • Interface for barcode reader • Manual or automatic setting of limit value A security inspection according to BGV A3, VDE 0701 and VDE 0702 is absolutely required after the maintenance and repair of portable instruments as well as for fist and repeated inspections. With the PAT Tester 0701/0702S you have the possibility to perform measurements, to check the abidance of the limit values. • Earth bond resistance • Insulation resistance • Substitute leakage current • Earth leakage current • Touch leakage current The perfect test instrument for handcraft, trade and industry in the domains of household appliances, IT and copiying for service, repair and maintenance. The memory for 800 measured values, the interface and software allow a further processing of the stored measuring values or a print-out as a test log. The adjustment of the thesting process and the measurement with Autotest can also be made fully automated by PC.(remotely controlled by PC) Function Earth bond resistance Insulation resistance Substitute leakage current Earth bond current Touch leakage current Power supply voltage Power consumption Test voltage Protection class Accuracy Operation temperature range Dimension W x H x D Weight Standard Accessories Range Measuring current Rated voltage 0 - 1000 mΩ > 200 mA AC 20 V AC max. 0,2 - 10 MΩ IK < 4,8 mA Un= 500 V DC 0 - 20 mA > 40 V AC 0 - 10 mA (Differential current measuring procedure) 0 - 10 mA AC/DC 230 V AC 50 Hz appr. 6 VA 2 kV I Class 2,5 0 … 15 … 35 … + 50° C 200 x 150 x 60 mm 1,1 kg (without test leads) Autotest 701/702S, carrying case, manual, PC Standard software, PC interface cable (9-pole), alligator clip, test lead Hole Punch LZ-1 Test Labels (German Version only) ø 15 mm, 160 pcs. ø 30 mm, 100 pcs. 40 AUTOTEST 0701/2 S PDA-Set Set of organizer (Palm) with bar code scanner, interface cable, e-manager External Mini printer HT 24 Bar code scanner Autotest Extern Bar code printer CEE 16/32 A Adapter for Autotest Bar code software label maker Professionally create standard conforming bar code labels in a few minutes. AUTOTEST 0701/0702 plus 0751 Portable Appliance Tester according to DIN VDE 0701, DIN VDE 0702 and BGV A3 for measurement of portable instruments, incl. electro-medical instruments according DIN VDE 0751. • Automatic or manual testing process • Comfortable operation by dialog promting on LCD display • Memory for max. 800 values • Automatic power plug pole reversal • Differential current measuring procedure • RS 232 C interface • Interface for barcode reader • Manual or automatic setting of limit value VDE Test Instruments PAT Instrument A security inspection according to BGV A3, VDE 0701, VDE 0702 and VDE 0751 is absolutely required after the maintenance and repair of portable instruments as well as for fist and repeated inspections. With the PAT Tester Autotest plus 0751/0702 you have the possibility to perform measurements, to check the abidance of the limit values. • Earth bond resistance • Insulation resistance • Substitute leakage current • Earth leakage current • Touch leakage current The perfect test instrument for handcraft, trade and industry in the domains of household appliances, IT and copying for service, medical appliances, repair and maintenance. The memory for 800 measured values, the interface and software allow a further processing of the stored measuring values or a print-out as a test log. The adjustment of the thesting process and the measurement with Autotest can also be made fully automated by PC (remotely controlled by PC). Function Earth bond resistance Insulation resistance Substitute leakage current Earth bond current Touch leakage current Power supply voltage Power consumption Test voltage Protection Class Accuracy Operation Temperature range General Data Standard Accessories Range Measuring Current Rated Voltage 0…1000 mΩ > 200 mA AC 20 V AC max. 0.2…10 MΩ IK < 4.8 mA Un= 500 V DC 0…20 mA > 40 V AC 0,000…10,00 mA (Differential current measuring procedure) 0,000…10,00 mA 230 V AC 50 Hz appr. 6 VA 2 kV I Class 2,5 0…15…35…+ 50° C Weight: 1.1 kg (without test leads), W x H x D: 200 x 150 x 60 mm Carrying case, PC standard software, PC interface cable (9-pole), alligator clip, test lead and manual Hole Punch LZ-1 Test Labels (German Version only) ø 15 mm, 160 pcs. ø 30 mm, 100 pcs. AUTOTEST 0701/2 S PDA-Set Set of organizer (Palm) with bar code scanner, interface cable, e-manager External Mini printer HT 24 Bar code scanner Autotest Extern Bar code printer CEE 16/32 A Adapter for Autotest Bar code software label maker Professionally create standard conforming bar code labels in a few minutes. 41 PAT Tester 0701/0702S PAT Tester for testing portable instruments according to DIN VDE 0701, DIN VDE 0702 and BGV A3 (BGV A2) • Automatic or manual testing process • Comfortable operation by dialog promting on LCD display • Memory for max. 800 values • Automatic power plug pole reversal • Differential current measuring procedure • RS 232 C interface • Interface for bar code reader • Manual or automatic setting of limit value With the PAT Tester 0701/0702S you have the possibility to perform following measurements, to check the abidance of the limit values: • Earth bond resistance • Substitute leakage current • Touch leakage current • Insulation resistance • Earth leakage current • CEE electrical test outlets 16A/32A for testing three-phase current loads (protective conductor testing, insolation testing, equivalent conductor current testing) • 3 1/2 digit display for measuring the current consumption of the test item The perfect test instrument for handcraft, trade and industry in the domains of household appliances, IT and copying for service, repair and maintenance. The memory for 800 measured values, the interface and software allow a further processing of the stored measuring values or a print-out as a test log. The adjustment of the thesting process and the measurement with PAT Tester 0701/0702S can also be made fully automated by PC. Function Earth bond resistance Insulation resistance Equivalent leakage current Earth bond current Touch leakage current Power supply voltage Power consumption Test voltage Protection class Accuracy Operation temperature range Dimension W x H x D Weight Standard Accessories Range Measuring current Rated voltage 0 - 1000 mΩ > 200 mA AC 20 V AC max. 0,2 - 10 mΩ Un = 500 V DC 0 - 20 mA > 40 V AC 0 - 10 mA (Differential current measuring procedure) 0 - 10 mA AC/DC 230 V AC 50 Hz appr. 6 VA 2 kV I Class 2,5 0 … 15 … 35 … + 50°C 400 x 330 x 170 mm appr. 6,2 kg PAT Tester, manual, PC standard software, PC interface cable (9-pole), alligator clip, test lead Hole Punch LZ-1 Test Labels (German Version only) ø 15 mm, 160 pcs ø 30 mm, 100 pcs 42 Rated current 350 mA In = 1 mA Short circuit current Ik = 4,8 mA PAT Tester 0701/2 S PAT Tester 0701/2 SZ Execution “Z” with Connector for External Clamp-On PAT Tester 0701/2 SD with buildt-in printer PDA-Set Set of organizer (Palm) with bar code scanner, interface cable, e-manager Bar code scanner Autotest extern Bar code printer extern Clamp-On KEW 8141 PAT Tester 0751 Plus VDE Test Instruments PAT Tester for testing portable instruments according to DIN VDE 0701, DIN VDE 0702 and BGV A3 (BGV A2) incl. Medical Appliance Testing • Automatic or manual testing process • Comfortable operation by dialog promting on LCD display • Memory for max. 800 values • Automatic power plug pole reversal • Differential current measuring procedure • RS 232 C interface • Interface for bar code reader • Manual or automatic setting of limit value With the PAT Tester 0751 Plus you have the possibility to perform following measurements, to check the abidance of the limit values: • Earth bond resistance • Substitute leakage current • Touch leakage current • Insulation resistance • Earth leakage current • CEE electrical test outlets 16A/32A for testing three-phase current loads (protective conductor testing, insolation testing, equivalent conductor current testing) • 3 1/2 digit display for measuring the current consumption of the test item The perfect test instrument for handcraft, trade and industry in the domains of household appliances, IT and copying for service, repair and maintenance. The memory for 800 measured values, the interface and software allow a further processing of the stored measuring values or a print-out as a test log. The adjustment of the thesting process and the measurement with PAT Tester 0701/0702S can also be made fully automated by PC. Function Earth bond resistance Insulation resistance Equivalent leakage current Earth bond current Touch leakage current Power supply voltage Power consumption Test voltage Protection class Accuracy Operation temperature range Dimension W x H x D Weight Standard Accessories Range Measuring current Rated voltage 0 - 1000 mΩ > 200 mA AC 20 V AC max. 0,2 - 10 mΩ Un = 500 V DC 0 - 20 mA > 40 V AC 0,000 - 10,00 mA (Differential current measuring procedure) 0,000 - 10,00 mA 230 V AC 50 Hz appr. 6 VA 2 kV I Class 2,5 0 … 15 … 35 … + 5°C 400 x 330 x 170 mm appr. 6,2 kg PAT Tester, manual, PC standard software, PC interface cable (9-pole), alligator clip, test lead Hole Punch LZ-1 Test Labels (German Version only) ø 15 mm, 160 pcs ø 30 mm, 100 pcs Rated current 350 mA In = 1 mA Short circuit current Ik = 4,8 mA PAT Tester 0751 Plus PAT Tester 0751 Plus Z Execution “Z” with Connector for External Clamp-On PAT Tester 0701/2 SD with buildt-in printer PDA-Set Set of organizer (Palm) with bar code scanner, interface cable, e-manager Bar code scanner Autotest extern Bar code printer extern Clamp-On KEW 8141 43 The Future has begun • Professional PAT-Tester • carries complete description of all test items to your location • arries all available former test data and specific test parameter to the test location • permits fast and secure manual input of visual test results • increases the productivity of serial persistance check according to VDE 0702 • paperless and complete recording of all new test items e-tester 0701/2 e-tester 0701/2 without e-manager pro The e-tester 0701/2 permits a trouble-free and safe execution of all tests according to VDE 0701/2 and a fast generation of test protocols. The e-tester is consequently the basis for a profitable execution of your order. Including a PDA the e-tester consists of an electronics assembly that can measure earth bond resistance, insulation, substitute leakage current, touch leakage current and it permits the manual data input, start command, display of the measured values, etc. With the e-tester/PDA set it is possible to carry former test results to the new test location without the need of a Laptop. Thanks to that portability, the whole information of test items and description of all tests to be undertaken, as well as limit values and specials are available on location. The test item can be found in the database in one working step by scanning the barcode or transponder. All predefined test steps and parameter including all limit values are directly available and the test can be made at once. Function Earth bond range Insolation test Substitute leakage current Earth bond current Touch leakage current Range 0 - 1000 mΩ 0,2 - 10 mΩ 0 - 20 mA 0 - 10 mA 0 - 10 mA AC/DC Power supply Power consumption Test voltage/Safety class/Accuracy Accuracy Operation temperature Dimension W x H x D/Weight Current > 200 mA AC Nominal Voltage 20 V AC max. Un= 500 V DC > 40 V AC Differential current measuring procedure Nominal Current 350 mA In= 1 mA 230 V AC 50 Hz appr. 6 VA 2 kV/I Class 2,5 0 … 15 … 35 … + 50 °C 425 x 337 x 111 mm/5,3 kg Standard Accessories: VDE 0701/2 test instrument in shock resistant, dust- and water-proof case incl. organizer (Palm), barcode scanner (module), test leads and test and protocol software e-manager pro. 44 Transponder Maintenance-free contactless identification Radio frequency identification (RFID) is a method of remotely storing and retrieving data using devices called RFID transponders. An RFID transponder is a small object, that can be attached to or incorporated into a product. RFID transponders contain antennas to enable them to receive and respond to radio-frequency queries from an RFID transceiver. Passive RFID tags do not have their own power supply. RFID transponders allow a worldwide unique Identification. TP-Handheld reader USB Frequency Dimension W x H x D Weight The Handheld reader is designed for connection to PCs and Desktops. TP-Handheld reader USB 125 kHz 45 x 100 x 25 mm 90 g TP-Handheld reader USB • Handheld reader with USB interface TP-Chip 20/TP-Chip 30 VDE Test Instruments RFID Transponders TP-Chip is a product from our portfolio with a very good price/performance ratio that can fulfil most of the requirements found in industrial and logistics application. The TP-Chip have been world wide successfully implemented in applications such as waste management, pallets identification, warehouse, process control and a lot more. TP-Chip 20/TP-Chip 30 • 2 diameters - 20 and 30 mm • Centred hole for the 30 mm disc • Polycarbonate housing • Operating temperature -25 to +70°C • IP 67 TP-Chip 20 TP-Chip 30 TP-Chip 30W Like TP-Chip 30 but with a white housing TP-Chip 30W • Diameters: 30 mm, Thickness 2 mm • Centred hole • Polycarbonate housing • Operating temperature -25 to +70°C • IP 67 TP-Chip 30W TP-Cleardisc Cleardiscs are a family of passive contactless transponders. Due to their design, material and easy handling the Cleardiscs are ideal for integrating into your individual package designs or can be used as a directly attached identification device. TP-Cleardisc • Diameters: 20 mm • Thickness: 0.6 mm • Polyethylen & Polyester (outside) • transparent • Operating temperature -20 to +60°C TP-Cleardisc TP-Glastag Glass TAGs are suitable for many applications where a small size, chemical or humidity resistance is required. TP-Glastag • Dimensions: 3.15 x 13.3 mm • Material: Glass • Operating temperature -40 to +85°C • IP68 TP-Glastag TP-Logitag 120 The Logitag 120 is a small transponder with high mechanical, chemical and temperature resistance. It is suitable for many logistics applications in harsh environment or if a good performance size/reading distance is requested. TP-Logitag 120 • Diameter 12.4 mm, thickness 2 mm • Material: PPS and Epoxy • IP68 • Peak temperature up to 160°C (time limitation) TP-Logitag 120 TP-Pigring Reclosable Pideonring transponder for application in agriculture or for labeling of electrical cables or extension cords. TP-Pigring • Inner diameter: 9 mm • Height of ring: 11 mm • Weight: 2 g • Thickness: 1 mm • Reclosable TP-Pigring 45 POWERTEST 0701/0702 3P VDE 0701/2 Test device for the safety testing of three-phase and alternating current consumers according to BGV A3 (BGV A2) (German-Occupational Safety Regulations) Incl. output measurements for the 1 or 3-phase devices up to 25 kW (or 32 A, resp.). • Tests according to BGV A3 (BGV A2) • For all test samples with grounded plugs, IEC plugs, 16 A 1P CEE, 16 A 3CEE and 32 A 3CEE connection. • Testing of extension cables. • Automatic test routine, plain-text operation and OK/Fault indication • Function test with real effective value output display • Memory in basic device • Data input through keypad, barcode reader or PC. • Checking the power connection for induction and PE connection. Automatic cutoff in case of hazardous fault current of the test sample. • No need to re-connect test samples • Temperature and pickup ammeter measurements • Test management with integrated schedule monitoring and option to retrieve due dates • Remote control and display in test probe Characteristics: The test device 0701/0702 3 P is used to perform checks following repairs and to perform repeat testing of non-stationary inspection, measuring and test equipment with a connection rating of up to 25 kW. It contains all common plug receptacles for alternating and threephase current consumers. For the convenient testing of extension cables, plugs have been arranged opposite the plug receptacles. The power supply takes place through a 32 A-CEE plug receptacle. Power cables for 16 A-CEE and grounded plugs are available. The device and its accessories are housed in a sturdy measuring case. The POWERTEST 0701/0702 3 P is equipped with a few features for the protection of the tester: • The 16 A circuits are protected by separate fuses in the device. • An integrated fault current monitor automatically cuts off the power supply from the test sample in case of hazardous fault currents (greater than 20 mA). • A connection identifier detects the presence of the PE connection in the system and checks the induction of the power supply. All of the measurements take place through instrument leads with integrated line compensation. All measurements stipulated according to DIN VDE 0701 and DIN VDE 0702 can be conducted. Passive measurements (test sample is not supplied with current): • Ground conductor resistance • Insulation resistance • Alternate leakage current Active measurements (test sample is supplied with current through a contactor) • Ground conductor current (differential current method) • Contact current • Voltage, current and output measurement through the full rated output. Continuous differential current measurement takes place parallel to the output measurement. 46 Powertest 0701/0702 3P The following individual measurements can be performed in addition: • Temperature measurements using an adapter • Pickup current measurement Operation is done with the help of a menu with backlit LCD display. To do justice to different user groups, the user profiles "Professional" and "Beginner" can be set. Prior to the test, the test specimen is classified to define the test routine and the setting of the threshold values according to the VDE regulation chosen (e.g., class of protection, heating capacity, length of ground conductor). Separate routines are available for extension cables and hard-wired devices. The measuring values are stored automatically in the device and can subsequently be read, printed or archived through the PC and a convenient database and logging software (optional). The test specimens are differentiated by entering an identification number through the keyboard or through a barcode reader that can be connected to the interface. VDE Test Instruments POWERTEST 0701/0702 3P Measurements (Nominal range error max. 5% of b.) Ground conductor resistance Insulation resistance Alternate leakage current Differential current Contact current Voltage per phase Current per phase Overall consumption Induction detection Ground conductor monitoring Integrated fault current cutoff Temperature measurement Pickup current measurement Voltage Test routines 0.000 Ohm … 4.000 Ohm, No-load voltage 6 V, current 200 mA DC 0.00 MOhm … 20.00 MOhm No-load voltages 500 V, 1000 V Short circuit current 1 mV 0.00 mA … 40.00 mA No-load voltage approx. 150 V 0.00 mA … 40.00 mA Filter characteristics according to DIN VDE 0404 for the current assessment of the harmonic waves 0.000 mA … 4.000 mA 0.0 V … 260.0 V 0.00 A … 40.00 A 0 W … 40,000 W, Recorded to the 15th harmonic wave AC, right, error Voltage N-PE > 30 V Differential current > approx. 20 mA 1°/mV 1 mA/mV, 1 A/mV (differential current and rated current) 0 … 400 mV, 0 … 400 V DC, peak, AC TRMS Regulation DIN VDE 0701/DIN VDE 0702 · SKI active /passive (with or without power supply) · SKII · Hard-wired · Extension cable · Individual measurement Technical characteristics: Power supply (mains) Switching capacity Ambient operating temperature Dimensions Weight Interface Memory, clock Integrated accessories Optional accessories Three-phase current with neutral or alternating current 400/230 V+/- 10 % Integrated industrial contactor: 40 A 0 °C - 40 °C Case with lid 530 x 330 x 230 mm Approx. 7 kg RS232, Connection with option of using adapter to USB or Ethernet, remote control capable 1000 measurement logs with date and timestamp Measuring cable with alligator clip 2 m, CEE 32 A connecting cable, test certificate Barcode reader, barcode printer, connection adapter CEE 16 A, ground contact, PC software, remote control 3 with logging and database function. 47 MT-100 NEW Multifunction TRMS DMM & 16th edition installation tester Test verifies reference standards: • Continuity test with 200 mA: EN 61557-4 • Insulation resistance: EN 61557-2 • Earth resistance: EN 61557-5 • RCDs test: EN 61557-6 MT-100 Optional accessories: Leakage current clamp A-300 1 mA to 200 A AC current clamp A-400 1 A to 400 A AC Leakage current clamp A-97 1 mA to 1000 A AC AC/DC current clamp CT-30 3 mA to 30 A AC/DC DMM Features • DC Voltage • AC TRMS Voltage • AC TRMS Current with external Clamp (optional) • AC TRMS Leakage current with external Clamp (optional) • DC Current • Resistance • Continuity test with buzzer • Frequency with test leads • Frequency with External Clamp • MIN/MAX/AVG functions • PEAK function with response time 1ms • HOLD function Safety test Features • Continuity test of protective conductors with 200 mA • Insulation Resistance measurement with 500 V DC • Trip-out time of RCDs type AC Standard with test current of 30 mA, 30 x 5 mA, 100 mA, 300 mA • Loop resistance without RCD tripping • Phase sequence indication at 1 or 2 wires • Phase coincidence indication at 1 or 2 wires • Leakage current (with A97 optional clamp) • AUTOTEST function: automatic sequence test of Loop resistance + RDC test + Insulation test with OK/NOT OK indications • Auto Power OFF • Low battery indication MULTITEST MT-100 is an innovative instrument which joins together DMM and 16th edition Safety Tester features inside a compact and ergonomic user-friendly structure and with a extremely reduced weight (800g only!). The Safety Tester features allow to perform test on electrical plants according to EN61557. Measure of Continuity, Insulation Resistance, Loop resistance (also with 0.1 Ohm resolution), RCDs test, phase sequence indication and phase coincidence (using only one Test Lead even just touching even insulated cables or two Test Leads) and Leakage current (with optional A97 clamp) will be easily performed thanks to this new extremely compact instrument. The DMM is a professional instrument with TRMS measurement of AC/DC voltage, AC/DC Current (through external clamp), Resistance and Frequency. Additional features are MAX/MIN/AVG function, HOLD function and PEAK detection with Response Time of 1ms, useful for surge currents detection. An innovative function (AUTOTEST) automatically performs main safety checks in the plant (Earth Resistance measurement, RCD Test, Insulation Test) just connecting the instrument to a socket and pressing the TEST button. The instrument will give you a final response (OK or NOT OK) about the safety of the plant under test. MT-100 is completed by a modern selector function knob, a large numeric display for easy readings of measurements and a protection rubber holder to prevent accidental damaged. 48 MT-100 NEW VDE Test Instruments Multifunction TRMS DMM & 16th edition installation tester Technical Specifications – DMM Functions* Accuracy is indicated as ± (% reading + no. of digits) at 23° C ± 5° C, relative humidity HR < 70 % DC Voltage (Autorange) Range 1.0 mV - 999.9 mV 1.000 V - 9.999 V 10.00 V - 99.99 V 100.0 V - 605.0 V Resolution 0.1 mV 1 mV 10 mV 100 mV Accuracy Input impedance Overload protection ± (0.5 % rdg + 2 dgt) 1 MΩ 605 Vrms max Accuracy (30 - 70 Hz) Accuracy (70 - 400 Hz) Input impedance AC Voltage TRMS (Autorange) Range Resolution 1.0 mV - 999.9 mV 1.000 V - 9.999 V 10.00 V - 99.99 V 100.0 V - 605.0 V 0.1 mV 1 mV 10 mV 100 mV Crest factor 3 ± (1.0 % rdg + 2 dgt) ± (2.0 % rdg + 2 dgt) 1 MΩ 1.5 DC/AC Current TRMS (with external clamp) Range Resolution DC Accuracy Accuracy (30 - 70 Hz) Accuracy (70 - 400 Hz) Input impedance Crest factor 1.0 mV - 999.9 mV 1.000 V - 1.200 V 0.1 mV 1 mV ± (0.5 % rdg + 2 dgt) ± (1.0 % rdg + 2 dgt) ± (2.0 % rdg + 2 dgt) 1 MΩ 3 1.5 Accuracy Overload protection ± (1.0 % rdg + 5 dgt) 605 Vrms max for 1 minute Accuracy Input Impedance Overload protection ± (0.5 % rdg + 2 dgt) 1 MΩ 605 Vrms max Accuracy Input Impedance Overload protection ± (0.5 % rdg + 2 dgt) 1 MΩ 605 Vrms max Resistance and Continuity Test Range 0.00 Ω - 39.99 Ω 40.0 Ω - 399.9 Ω 400 Ω - 3999 Ω 04.00 Ω - 39.99 Ω Resolution 0.01 Ω 0.1 Ω 1Ω 10 Ω Frequency (with test leads) Range 30.0 - 199.9 Hz 200 - 400 Hz Resolution 0.1 Hz 1 Hz Frequency (with external clamp) Range 30.0 - 199.9 Hz 200 - 400 Hz Resolution 0.1 Hz 1 Hz Continuity test on protective and equalizing conductors Range (Ω) 0.01 - 19.99 20.0 - 99.9 Resolution (Ω) 0.01 0.1 Accuracy Overload protection ± (5.0 % rdg + 3 dgt) 605 Vrms max Accuracy Overload protection Insulations Resistance (500 V DC) Range (MΩ) 0.00 - 19.99 20.0 - 199.9 200 - 999 Resolution (MΩ) 0.01 0.1 1 ± (5.0 % rdg + 3 dgt) 605 Vrms max ± (10.0 % rdg + 2 dgt) Global Earth Resistance/Loop Resistance Test current 15 mA 100 mA Range (Ω) 1 - 1999 0.1 - 199.9 Resolution (Ω) 1 0.1 Accuracy ± (5.0 % rdg + 2 dgt) ± (5.0 % rdg + 3 dgt) Overload protection 605 Vrms max General Specifications Display Power Supply Dimensions/Weight Working Temperature Insulation Overvoltage category Standard Acessories Features: Dual numeric, 9999 points Battery: 4 batteries 1.5 V type LR6-AA W 240 x L 100 x D 45 mm/about 630 g included batteries 0° - 40° C, allowed relative humidity: < 70 % HR class 2 (double insulation) CAT III 550 V AC Phase-Ground Shuko plug cable SP-2, kit of 2 test leads, 2 alligator clips, carrying bag WP75, batteries, calibration certificate ISO9000, instruction manual 49 Genius 5035 VDE 0100 The intelligent VDE 0100 Test Instrument • Check • Analyse • Record Genius is unique. In addition to its use for installation testing to EN 61557 Genius can be used for the analysis of environmental measurements and power quality to EN 50160. RCDs wich suddenly trip, transformers which overheat, motors which burn out, voltage breaks and peaks which cause problems, all these can be easily solved with Genius. Thanks to its PC interface andpowerful software you can create a range of accurate and useful documents. Genius 5035 and Genius 80 E The VDE 0100 test instrument that you don't want to replace. Thanks to the newest applied technology you can aquire an effective instrument without additional financial expenditures. The Genius-VDE Test Instruments present a future-oriented development. The Genius Test Instrument is unique on the market. With the Genius Test Instruments you can perform following measurements according to VDE 0100 and VDE 0413 (EN 61557) • Insulation resistance VDE 0413 part 2/EN 61557-2 100 V, 250 V, 500 V, 1000 V DC • Line and loop impedance VDE 0413 part 3/EN 61557-3 and prospective short circuit current • Low resistance measurement VDE 0413 part 4/EN 61557-4 with > 200 mA DC • RCD-Analysis VDE 0413 part 6 Measurement of tripping time, tripping currrent, touch leakage voltage Ub with and without RCD tripping • Measurement of earth resistance without causing RCD tripping • Phase Rotation Frequency and Voltage Measurement • additional features of Genius 80 E VDE 0413 part 5/EN 61557-5 VDE 0413 part 7/EN 61557-7 Measurement and recording of current, voltage, power, cos º, harmonics, residual voltage, voltage drops and voltage peaks Genius 80 E can be emplyed for testing civil and industrial electrical installations, tracking of faults due to bad insulation, checking proper working of RCDs, measuring earth resistance of both simple (TT) and complex (TN) systems as well as measuring ground resistivity for designing of the earth installation. Thanks to the integrated memory and PC interface you can create exact documentations that show your professional competence. Genius 5035 50 Technical data on page 52 · Accessories on page 108 Genius 80 E VDE 0100 + Power Analysis NEW Power Analysis VDE Test Instruments For 3 Phase Power Analysis see page 66, Model GSC-53 A. Scope mode Harmonics The measuring quantities are displayed in numerical, graphical and histogram form. The Genius products are provided with a powerful micro processor to store and register measuring quantities that are not only indicated on the graphic display but also can be printed out or sent to a PC to create test reports or fill out certificates with the analyse and protocol software for Windows. The Genius 80 E comes out with an analog input by standard. Thanks to the analog input, the Genius carries out measurements and recordings of environmental parameters (with adapters) as lux, environmental temperature (C°), humidity (H%) and sound level dBA Type 1. The current transducer A 97 is qualified for significant measurement of current from 1 mA up to 1000 A. All important information and data are indicated on a large grafic-display with high resolution and back light. For the analysis of power quality Genius carries out single-phase measurements and recordings of: • AC current • Power, Energy • Analysis of harmonics and THD • AC voltage • Frequency • Power factor • Active power • Voltage anomalies Sag and Surge • Reactive power Welcome into the future. Standard Accessories Genius 5035 Genius 80 E incl. carrying case, 3-wire Shuko cable, kit of 3 cables, 4 crocodiles and 2 test leads, 4 banana-banana and 4 earth rods, software on CD-ROM, RS232 serial cable, batteries, manual and calibration certificate. as Genius 5035, additionally with Power Analyzer function, 1 Mini Clamp-On A 200 (from 1A up to 200 A) Genius 80 E incl. 1phase power analyse GSC-53 A incl. 3 phase power analyzer technical data on page 52 and 66. Technical data on page 52 51 Genius 5035 + Genius 80 E + GSC-53 A Technical Data General data of Genius 5035 + 80 E + GSC-53 A Display Memory Interface Recording interval Memory Genius 80 E GSC-53 A Auto power off Grafic display, back light (only 80 E + GSC-53 A) 128 kbyte (Genius 5035) RS232 adjustable from 5 sec. up to 15 min. (only Genius 80 E + GSC-53 A) 2 MB, for appr. 700 - 1000 measuring quantities for VDE 0100 resp. max. 67 days recording 10 min. Technical features of Genius 5035 + 80 E + GSC-53 A Analog input (only Genius 80 E + GSC-53 A) Resolution Accuracy Temperature adapter (HT52) Humidity (HT52) Intensity of light (HT53) Low Ohm range (Low resistance measurement) Resolution Accuracy Test current Open circuit viltage Test lead compensation Insulation resistance Test current Range Resolution Accuracy Open circuit voltage Short circuit current Rated voltage -1000 m VDC - +1000 mV DC 0,1 mV ± (2 % reading + 2 digits) -40 °C - 80 °C 10 - 98 % RH 0 - 20.000 Lux 0 - 20 Ohm 0,01 Ohm ± (2 % reading + 2 digits) > 200 mA DC > 4,5 V Yes General data of Genius 5035 + 80 E Autonomy Operation temperature Relative humidity Safety: EN61010 Protection class Dimension Weight Power supply 5000 measurements 0 - 40 °C 85 % CAT III 600 V IP50 225 x 165 x 120 mm appr. 1500 g 6 x 1,5 V, AA LR6 Technical features of Genius 5035 + 80 E + GSC-53 A Earth resistance RE without RCD tripping Accuracy AC Voltage Range Resolution Accuracy Current (with Clamp-On A 200 only Genius 80 E) Range Basic accuracy Frequency Range Resolution 100, 250, 500, 1000 V DC 0 - 1,999 MOhm 2 - 19,99 MOhm 20 - 999,9 MOhm 1 kOhm 10 kOhm 100 kOhm ± (2 % reading + 2 digits) 1,3 x Test voltage 1,4 mA (max.) 1 mA Accuracy Phase sequencing RCD tests 200 A/1 V ± (1 % ± 0,25 mV) 15,3 - 99,9 Hz 100 - 499 Hz 0,1 Hz 1 Hz ± (0,1 % + 2 digits) L1, L2, L3 or L2, L1, L3 AC, A and selective 10 mA, 30 mA, 100 mA 300 mA, 500 mA, 1000 mA Test current Resolution Accuracy 1/2 IΔN 2 IΔN 5 IΔN RCD S** 5 IΔN RCD** 0 - 1999 ms 0 - 199,9 ms 0 - 150 ms 0 - 40 ms 0,1 ms* ± (2 % reading + 2 ms) Range Resolution Accuracy (0,5 - 1,4) IΔN 0,1 IΔN ± 0,15 IΔN Trip Time (IΔN) *) with control of contact voltage **) excluding 500 mA and 1000 mA Range Range 52 500 V 1V ± (2 % + 2 digits) RCD type Rated tripping currents Earth resistance 0 - 19,99 Ohm 20 - 199,9 Ohm 200 - 1999 Ohm Resolution 0,01 Ohm 0,1 Ohm 1 Ohm Accuracy ± (2 % reading + 2 digits) Frequency 125 Hz ± 1 Hz (Sinus) Test current ≤ 10 mA Open circuit voltage ≤ 80 V Loop Impedanz Phase-Phase(Zpp), Phase-Neutral (Zpn),Phase-Earth (Zpe) Range 0 - 19,99 Ohm 20 - 199,9 Ohm 200 - 1999 Ohm Resolution 0,01 Ohm 0,1 Ohm, 1 Ohm Accuracy ± (5 % reading + 3 digits) Measuring 10 A ± 10 % (10 ms) Calculation of short circuit current Ik max (theoretically) 40 kA Earth resitance RE without RCD tripping Range RE 0,1 Ohm - 10 kOhm Test current 0,5 IΔN RCD + 10 % - 0 % ± 0,2 V/IΔN Trip current Touch current Range Resolution Accuracy UB lim: Power (only Genius 80 E + GSC-53 A) Accuracy Resolution Harmonics (only Genius 80 E + GSC-53 A) Range Accuracy Safelty: IEC 1010 (VDE 0411) all measurement according to VDE 0413 (EN 61557) 0 - 100 V 0,1 V + 10 % - 0 % of UBlim 25 V or 50 V 0,7 % ± 2 digit 10 W 2. - 50. harmonic 0,7 % ± 2 digits Accessories on page 108 HT53 (only Genius 80 E) Range Output 0,00 - 20.000 Lux 1 mV/1 Lux, 1 mV/0,01 Lux 1 mV/10 Lux HT52 (only Genius 80 E) Range Output Accuracy Power supply - 20 … + 60° C, 0 - 100 % RH 1 mV /C°, 1 mV/% RH ± 2,5 % RH, ± 0,7° C 9 V battery/150 h A 97 (only Genius 80 E) Range Output Range Conductor diameter Dimension Weight from 1 mA up to 1000 A 1 mV/1mA to 1 mV/1 A 1 A, 100 A, 1000 A AC up to Ø 54 mm 95 x 210 x 35 mm 570 g A-200 (only Genius 80 E) Range Output Conductor diameter Dimension Weight 1 - 200 A 5 mV/1 A Ø 15 mm 43 x 97 x 23 mm 115 g A-300 (only Genius 80 E) Range Output Range Conductor diameter Dimension Weight 1 mA … 200 AC 1 mV/1 mA ... 5 mV/1 A 1 A, 10 A, 200 A up to 15 mm 43 x 97 x 23 mm 165 g Luxmeter HT53 Temperature and Humidity Probe HT52 VDE Test Instruments Genius 5035/80 E Adapters and Accessories Leakage Current Clamp-On A-97 Current Transducer Clamp-On A-200 Mini Clamp-On A-300 DAA-16, 3 Phase CEE Plug 16 A DAA-32 3 Phase CEE Plug with banana jacks DAA-32, 3 Phase CEE Plug 32 A Earth rods and leads 4 rods, 4 safety test leads (1 x 20 m, 1 x 15 m, 2 x 5 m) and carrying case Earth Cable Set external power supply 12 V/1200 mA Adapter A0050 Earth Cable Set A0050 Accessory for high Current Impedance Measurement. Up to 80 kA for Combitest 2019, Genius 5035, Genius 80 E und GSE-53 A IMP-57 Range Test current Voltage Dimension Weight 0,1 mΩ … 1999 mΩ max. 244 A 200 V - 440 V 340 x 300 x 150 mm 4,1 kg Adapter IMP-57 53 The New Generation of Modern VDE 0100 Test Instruments The Family 2000 Combitest Insulation Tester Speedtest Geotest • inclusive memory for 350 measurements • inclusive infrared interface • inclusive protocol software Eurolink 2000 Overview VDE 0100 (16th Edition) Installation Tester Serie 2000 Model Function Low ohm measurement according to VDE 0413 part 4 Insulation measurement according to VDE 0413 part 2 RCD testing according to VDE 0413 part 6 Loop and line impendance according to VDE 0413 part 3 Phase sequencing measurement according to VDE 0413 part 7 Earth resistance 2, 3, 4 point according to VDE 0413 part 5 Cataloque page Safety class Standard Accessories 54 Combitest 2019 Insulation Tester 2010 • • • • Speedtest 2018 • • • • • • Geotest 2016 • page 55 page 56 page 56 all: EN61010-1 CAT III 600 V all: incl. protective case, test leads, software (Eurolink 2000), memory, interface cable, batteries page 57 Accessories on page 108 Combi Test 2019 The small and fast tester VDE Test Instruments • VDE 0100/VDE 0105 • for fast and easy testing of electrical installations • compact, safe and reliable • Large and clearly arranged 3 1/2 LCD Display (64 x 64 mm) • Timer function and limit value adjustment • Integrated RS-232 interface • Internal memory for 350 measuring values • Auto off • Integrated rubber holster • Safety: IEC-1010-1, CAT III 600 V Optional working case WP 2000 S Function Low ohms measurement Insulation measurement 50 V, 100 V, 250 V, 500 V and 1000 V DC FI (RCD) tripping time FI RCD) tripping current FI (RCD) Ra FI (RCD) Ub Line/Loop impedance (Zs, Zi) Short circuit current Ik Loop impedance without RCD tripping Frequency measurement Phase sequence and voltage measurement RS 232 interface Memory locations Dimesions W x H x D Power supply Weight Auto off Safety class, standards Standard accessories • Low ohms measurement with 200 mA DC • Insulation resistance with 50, 100, 250, 500 or 1000 V DC • Complete RCD testing and analyse function • Line and loop impedance and current (Zi, Zs) • Display of short circuit curent Ik • Fault loop impedace without RCD tripping • Phase sequence measurement (VDE 0413, part 4, EN 61557-4) (VDE 0413, part 2, EN 61557-2) (VDE 0413, part 6) (VDE 0413, part 3, EN 61557-3) (VDE 0413, part 3, EN 61557-3) (VDE 0413, part 7, EN 61557-7) Range Resolution Accuracy 0,01 ÷ 19,99 Ω 0,01 Ω ± (5 % reading + 2 digits) 19,99 ÷ 99,99 Ω 0,1 Ω 0,01 MΩ ÷ 19,99 MΩ 0,01 MΩ ± (5 % reading + 2 digits) 20 MΩ ÷ 199 MΩ 0,1 MΩ 200 MΩ ÷ 1999 MΩ 1 MΩ adjustable test current IΔN: 10, 30, 100, 300, 500 mA 1 ms ± (2 % reading + 2 digits) tripping time (max. Range) 0 ÷ 9,99 Ω (0,5 ÷ 2,0) x IΔN 10 % IΔN - 0 %, +5 % 0 ÷ 2 kΩ/Itest =1/2 IΔN 1Ω ± (5 % reading + 2 digits) 25 or 50 V touch current 1V (+10 %, - 0 %) reading + 2 digits) 0,01 ÷ 19,99 Ω 0,01 Ω ± (2 % reading + 2 digits) 20,00 ÷ 199,9 Ω 0,1 Ω 200,0 ÷ 2000 Ω 1Ω Test current Itest 0 4 A (80 ms) at 110 V, 6 A (40 ms) at 230 V, 11 A (40 ms) at 400 V 1 A ... 1 kA ... 10 kA 1 A and 1 kA ± (2 % reading + 2 digits) 1 ÷ 1999 Ω 1Ω ± (5 % reading + 2 digits) 15,3 ÷ 99,9 Hz 0,1 Hz ± (0,1 % reading + 1 digit) 110 ÷ 440 V 1V ± (2 % range + 2 digits) optoinsulated serial output 350 163 x 222 x 57 mm 6 x 1,5 V Type AA for appr. 500 insulation measurements appr. 990 g 10 min EN 61010-1, CAT III 600 V, all measurements according to VDE 0413 (EN 61557) part 1, 2, 3, 4, 6 and 7 incl. carrying case, test leads with Shuko plugs, 3 alligator clips, 3 safety-test leads with banana jack, software (Eurolink 2000), memory, RS232 cable, manual, calibration certificate and batteries. Combi Test 2019 Optional working case WP 2000 S 55 Insulation Tester 2010 Insulation and Low Ohms Measurement VDE 0413 • Insulation measurement (VDE 0413/2) • Low ohm measurement (VDE 0413/4) • Insulation measurement 0 - 1999 MΩ with 50, 100, 250, 500, 1000 V DC • Low ohms measurement 0 - 99,99 Ω with audible signal • Selectable limit value and test duration in sec. • incl. software, memory for test values (350) and interface • Safety: CAT III 600 V Display Interface, memory Dimension W x H x D Weight Power supply Standard Accessories 3 1/2 LCD display, 64 x 64 mm optoinsulatet, 350 memory locations 163 x 222 x 57 mm appr. 900 g 6 x 1,5 V batteries Type AA Protective case, test lead-set, software, memory, interface cable, batteries Function Range Insulation resistance 0 - 1999 MΩ Low ohms measurement 0 - 99,99 Ω Accuracy ± 2 % + 2 digits ± 2 % + 2 digits Isotest 2010 permits to effect continuity test on main and auxiliary protective as well as potential equalising conductors (with a current higher than 200 mA and minimum open circuit test voltage equal to 4 V) and insulation test with voltages from 50 V to 1000 V and full scale up to 2 GOhms. Isotest 2010 is easy to handle, manageable and lightweight. The large LCD Display guarantees clearly and easy to read measuring values. Insulation Tester 2010 Test voltage/current 50, 100, 250, 500, 1000 V DC Ip > 200 mA DC Resolution 0,01 M Ω, 0,1 M Ω, 1 M Ω 0,01 Ω and 0,1 Ω Speed Test 2018 RCD and Loop Impedance Testing VDE 0413 • RCD Analyzer (VDE 0413/6) • Impedance measurement (VDE 0413/3) • Phase sequence measurement (VDE 0413/7) • RCD test with and without tripping or ramp test current • RCD tripping, RCD tripping current, touch current • RCD auto function, auto-tests all RCD parameters • Loop impedance Zs, line impedance Zi, between phase/phase and phase/N • incl. software, memory for test values (350) and interface • Safety: CAT III 600 V Display Interface, memory Dimension W x H x D Weight Power supply Standard Accessories 3 1/2 LCD display, 64 x 64 mm optoinulated, 350 memory locations 163 x 222 x 57 mm appr. 1000 g 6 x 1,5 V batteries Type AA protective case, 3-wire Shuko plug, software, memory, interface cable, batteries Measurement functions Range, Accuracy, Resolution 56 Speedtest 2018 is a multifunction instrument for testing of RCD's total earth resistance, line and fault impedance with calculation of prospective short circuit current and phase sequence indication, permits to check times both manually and automatically and tripping currents of any kind of RCD general and selective type A and AC, measure earth resistance directly in the socket without causing RCD tripping, effect measurement of line and/or fault loop impedance (with and without tripping of any RCD installed upstream) and calculation of prospective short circuit current. Speed Test 2018 loop impedance Zs, line impedance Zi, short circuit current Ik, RCD analysation, phase sequence, voltage, frequency see Combi Test 2019 on page 55 Accesorries on page 108 • Tester of Earth Resistance and Resistivity • VDE 0413 Part 5 (EN 61557-5) • Earth resistance (VDE 0413 Part 5) two, three, four point measurement • Specific earth resistance º • Automatic calculation of the mean value • Voltage measurement • incl. interface + memory Geo Test 2016 can carry out two- and three-wire earth resistance measurements as well as ground resistivity measurements on which the ground quality evaluation is based. This instrument permits to check both earth resistance of electrical installations and ground resistivity to be normally used when designing the earth installation. Display RS 232 interface Memory locations Dimension W x H x D Weight Power supply Standard Accessories 3 1/2 LCD display, 64 x 64 mm optoinsulated 350 163 x 222 x 57 mm appr. 900 g 6 x 1,5 V batteries Type AA Protective case, earth resistance test leads with 4 rods, protocol software, calibration certificate memory, interface cable, batteries VDE Test Instruments Geo Test 2016 The Earth Resistance Expert The instrument is battery-operated and very handy thanks to its dimension and light weight. A protective case is delivered as standard accessory for secure transport of Geo Test 2016 and the included asseccories. Geo Test 2016 Technical Data Function Earth resistance and resistivity RE (autorange) automatic compensation of conductor resistance and calibration at 2-, and 3-point measurement Range 0 - 19,99 Ω 20 - 199,99 Ω 200 - 1999 Ω Resolution 0,01 Ω 0,1 Ω 1Ω Accuracy Function Specific earth resistance p automatic compensation of conductor resistance and calibration at 3- and 4-point measurement Range 0 - 19,99 Ω/m 20 - 199,99 Ω/m 200 - 1999 Ω/m 2,00 - 19,99 kΩ/m 20,0 - 199,9 kΩ/m Resolution 0,01 Ω 0,1 Ω 1Ω 10 Ω 100 Ω Accuracy ± 2 % reading + 2 digits ± 2 % reading + 2 digits ± 2 % reading + 2 digits ± 2 % reading + 2 digits ± 2 % reading + 2 digits Function Voltage Range 0 - 400 V Resolution 1V Accuracy ± 2 % ± 2 digits ± 2 % ± 2 digits Comments: Frequency: 125 Hz ±1 Hz-Test current: < 10 mA; Open circuit current: 80 V, Sinus; Measuring error at interference voltage 20 Vss/50 Hz: ± 15 digits; Measuring error by earth resistance Rc and Rp each additionally: 3 % max. Rcmax resp. Rpmax = (4 kΩ + 1000 RE) ≤ 50 kΩ Rc = Rc1 + Rc2 (4 wire network) Rp = Rp1 + Rp2 (4 wire network) Accesorries on page 108 57 DGC-1000 A The Modern and Effective Way of Ground Resistance Testing • Ground resistance measurement without earth rods • No test leads or auxiliary electrodes necessary • Defines the earth loop resistance • Also qualified for residual current from 0,01 mA • 4 digit LCD display 9999 digits • Memory for 116 data values • with record function • Sampling interval 1 sec - 255 sec • High and Low Alarm • AC current from 0,2 mA to 30.00 A AC • Ground resistance from 0,025 Ω to 1500 Ω • max. conductor diameter Ø 23 mm • True RMS measurment • Safety: CAT III 300 V Recording Rate Memory Continuity check Crest faktor Measuring frequency Jaw opening Dimension W x H x D Weight Power supply Standard Accessories 1 sec - 255 sec 116 data values Buzzer sounds at < 40 Ω <3 1,667 kHz for conductors to 23 mm 100 x 257 x 47 mm incl. batteries 640 g 9 V battery incl. protective case, resistance loop and 9 V battery Technical Data Function Current A AC Ground resistance Range 0, 200 - 1,000 mA 1,00 - 10,00 mA 10,0 - 100 mA 100 - 1000 mA 0, 20 - 30,00 A 0,025 - 0,250 Ω 0,250 - 9,999 Ω 10,00 - 99,99 Ω 100,0 - 199,99 Ω 200,0 - 400,00 Ω 400,0 - 600,0 Ω 600,0 - 1500 Ω Resolution 0,001 mA 0,01 mA 0,1 mA 1 mA 0,01 A 0,002 Ω 0,02 Ω 0,04 Ω 0,4 Ω 2Ω 5Ω 20 Ω Accuracy ± 2,5 % ± 0,05 mA ± 2,5 % ± 0,05 mA ± 2,0 % ± 0,3 mA ± 2,0 % ± 3 mA ± 3 % ± 0,03 mA ± 1,5 % ± 0,05 Ω ± 1,5 % ± 0,1 Ω ± 2,0 % ± 0,3 Ω ± 3,0 % ± 1 Ω ± 5,0 % ± 5 Ω ± 10,0 % ± 10 Ω ± 20,0 % DGC-1000 A 58 VDE Test Instruments AMB-25 Insulation Resistance Tester 1 kV • Test insulation of wires, cables, transformers and electrical motors • Come as a complete kit incl. test leads • Selectable test voltages up to 1000 V • Programmable timer to perform the Dielectric Absorption Ratio Test • Resistance measurement • Internal memory (stores 9 readings) • Fast and easy to use, rugged durable design AMB-25 Function Insulation resistance with 250, 500 & 1000 VDC test voltages Resistance analogue Bar graph General Data Standard Accessories Range Resolution 0 … 4.000 MΩ 0,001 MΩ 40 MΩ 0,01 MΩ 400 MΩ 0,1 MΩ 2000 MΩ 1 MΩ 0,0 … 999,9 Ω 0,1 Ω 0 … 10 GΩ Weight: 550 g, L x W x D: 198 x 105 x 75 mm incl. batteries, holster, set of test leads and manual Accuracy ± (3,0 % rdg + 5 digits) < 1 GΩ ± (5,0 % rdg + 5 digits) < 4 GΩ 0,5 % rdg + 10 digits AMB-35 Insulation Resistance Tester 1 kV • Test insulation of wires, cables, transformers and electrical motors • Come as a complete kit incl. test leads • Selectable test voltages up to 1000 V • Programmable timer to perform the Dielectric Absorption Ratio Test • Sensitive Ohmmeter for checking resistance of motor windings • Built in voltmeter • Internal memory (stores 9 readings) • Fast and easy to use, rugged durable design AMB-35 Function Insulation resistance with 250, 500 & 1000 VDC test voltages Resistance Low Resistance AC/DC Voltage General Data Standard Accessories Range Resolution 0 … 4.000 MΩ 0,001 MΩ 40.00 MΩ 0,01 MΩ 400.0 MΩ 0,1 MΩ 4000 MΩ 1 MΩ 0,1…999,9 Ω 0,1 Ω 0,10 Ω … 40.00 Ω 0,01 Ω 0,1 … 1000.0 V 0,1 V Weight: 550 g, L x W x D: 198 x 105 x 75 mm incl. batteries, holster, set of test leads and manual Accuracy ± (3,0 % rdg + 5 digits) < 1 GΩ ± (5,0 % rdg + 5 digits) < 4 GΩ ± (1,0 % rdg + 2 digits) ± (2,0 % rdg + 2 digits) ± (2,0 % rdg + 1 digits) 59 MEGATEST-1 Digital Insulation Tester NEW Extreme handy digital Insulation Tester to 1000 V DC. • Large LCD display with 60 segment bar graph • Test voltage 250 V, 500 V, 1000 V DC • Insulation measurement to 4000 MΩ • Voltage to 600 V AC/DC • Acoustic continuity test • Memory for 4000 test values • with RS-232 interface (optically) • CAT III 600 V Function MΩ 250 V MΩ 500 V MΩ 1000 V AC Voltage AC Voltage OHM Measuring rate Dimension W x H x D Weight Power supply Safety Standard Accessories MEGATEST-1 Range Highest resolution Accuracy 4/40/400/4000 MΩ 1 kΩ ± 3 % + 5 dgt < 2 GΩ 4/40/400/4000 MΩ ± 3 % + 5 dgt < 2 GΩ 4/40/400/4000 MΩ 0 - 600 V 0,1 V ± 1,5 % + 5 dgt 0 - 600 V 0,1 V ± 1 % + 3 dgt 400 Ω 0,1 Ω ± 1 % + 5 dgt 4000 Ω 1Ω Buzzer sounds at values < 40 2,5 x/sec LCD display, 10 x/sec bar graph 116 x 230 x 62 mm 750 g incl batteries 8 x 1,5 V AA CAT III 600 V incl. batteries, protective case, test leads, software and RS-232 cable Insulation Tester AMB-5kV for systems, motors, transformators, cables, motor vehicles • Insulation measurement (VDE 0413 part 2) • Test voltage 500 V + 1000 V + 2500 V + 5000 V DC • Analog display 500 kΩ - 500 GΩ • Voltage measurement to 600 V AC/DC • Network-independent battery operation with low battery indicator • Safety: IEC 1010, highly insulated case Insulation Tester AMB-5kV Function Insulation resistance Test voltage AMB-5kV is a portable, network independent instrument for non-destructive measurements of insulation resistance of: • electrical systems • electrical installations in vehicles • HV cables • HV transformators • conductors • machines and electrical equiptment 60 Voltage measurement Display Voltage ranging Dimension W x H x D Weight Power supply Battery lifetime Low battery indication Standard Accessories Range Test current 500 kΩ - 500 GΩ 500 V= 1 mA > Iprüf ≤ 1,4 mA 1000 V, 2500 V= 0,5 mA > Iprüf ≤ 1,4mA 5000 V= 0,2 > Iprüf ≤ 1,0 mA 0 - 600 V=+~ Analog instrument with logarithmic scale, length 90 mm by rotary switch 370 x 245 x 150 mm 5 kg 4 x 1,5 V batteries IEC R20 (TYP D) Mono appr. 2500 measurements red LED indicator, if battery is too weak 1 high voltage test lead and cable for insulation measurements AMB-5kV is bordered in a robust, portable, highly insulated case. Accuracy ±2% ±2% ±2% ±2% ±2% ISO-Digi 5kV Digital Insulation Tester VDE Test Instruments Programmable Insulation Tester to 5000 V • Large LCD display • Bar graph display from 100 kΩ to 1 TΩ • Digital from 10 kΩ to 500 GΩ • Insulation measurement from 500 to 5000 V DC in steps of 25 V • Voltage measurement to 600 Volt AC • Programmable test procedure • RS-232 interface ISO-Digi 5kV This programmable 5 kV Insulation tester is designed for insulation measurements high voltage equipment in the industry and meets different demands of tests and service of: • Rotary machines • Transformators • High voltage insulation systems Thanks to its advanced technology Isotest-Digi 5 kV is intended for demanding and professional customers looking for accurate and reliable insulation measurements. It can also be employed to effect measurements monitoring the gradual decrease of the insulationvalue ocurring in case of external agents such as corrosion, dust, grease, humidity etc. during the normal working of an installation. Types of measurement: The instrument can carry out 4 types of measurements: MAN: set voltage and prass START key until the test ends AUTO: set voltage and measurement duration, measurement ends when the value measurend is stable within a range of 10% TIMER: set voltage and measurement duration, measurement ends when time set expires PROGR: set consecutively: · Final voltage · Duration of final voltage provision · Starting voltage · Increase time from starting voltage to final voltage · The measurement ends when sum of both times has elapsed. General Data Test voltage Range Ω Accuracy Limit of generated current Discharge time Voltage measurement Power supply Operating temperature Memory RS232 Compliance Dimension W x H x D Weight Standard Accessories 500 V - 5000 V in 25 V steps 10 kΩ - 1 TΩ 5% < = 1,4 mA < 2,5 s per μF to 600 Vrms Stop of measurements in the presence of dangerous voltage on test leads Discharge of any residual voltage at the end of measurements Display of real voltage on the test leads 4 x 1,5 V batteries type D or LR 20; low battery indicator 5 to 40° C 20 memory locations for parameters; 200 memory locations for measurements DIN 9-pole (4800, 9600 baud) IEC61010-1, EN50081-1, EN50082-1, EN60439 for measurements to 500 V 340 x 150 x 290 mm appr. 4 kg 3 test leads with alligator clips, software EUROLINK incl serial cable, manual and batteries 61 SAFETEST For Installations and Machines Machine tester, espacially for acceptance of elektrical machines, installations and panel boards EN 60204-1 VDE 0113 CAT II 600 V • Insulation measurement 500 V DC • Continuity test 6 V/10 - 25 A • Continuity test 12 V/> 10 A • Voltage test (withstanding) to 1000 V (500 VA) • Residual voltage measurement Memory Case Dimension W x H x D Weight Power supply Standard Accessories 700 memory locations Waterproof ABS-case 360 x 270 x 160 mm appr. 8 kg inclusive accessories External power supply 230 V AC/50 Hz test leads, RS-232 interface, protocol software, interface cable, calibration certificate Technical data according to EN 60204-1 Withstanding Desruptive test (Burn) Range + Resolution 0 - 1 kV Accuracy of display ± (5 % + 20 V) Insulation Resistance 0 - 99,99 MΩ 10 kΩ ± 2 % ± 3 digits 500 V DC 2,2 mA (4 mA max) at 230 kΩ 0-1Ω (0,001 Ω) 0 - 10 V (0,01 V) ± 2 % + 3 digits ≤ 6 V AC or < 12 V AC > 10 < 25 A* or > 10 A Continuity (Resistance measurement) Voltage drop measurement Residual voltage measurement internal and external 0 - 10,0 s (Power plug) Test voltage 1000 V AC/50 Hz 0,5 - 500 mA (1180 Vmax) > 200 mA ± (2 % + 0,03 V) ± (5 % + 0,1 s) Test current • Adjustment of limit value • Adjustment of testing period (Timer) • 700 memory locations • Microprocessor controlled • PC interface (RS-232) + software • Rugged and waterproof case Test time Comments 1s to 10 min 1s to 10 min digital display of test voltage and test current power 500 VA 1s to 15 s Possibility to adjust a limit value + timer Selectable for testing the permitted section: 1- 1,5 - 2,5 - 4 and > 6 mm2 max. 750 Vp Input resistance of test inputs: 88 MΩ Limit value 60 V *by request also deliverable with > 25 A Safetest incl. Protocol Software Remote control RCA Mini Printer HT24 Insulation measurement with 500 V DC 62 Continuity test on electrical equipment Continuity check with Ip >10 A on panel board Residual voltage measurement EN 60204-1, EN 60439-1 VDE 0113 appliance tester for installations, machines and medical instruments. CAT II 600 V • Insulation measurement 500 V DC • Continuity testing (10 A), resistance and voltage drop • Continuity testing, 6 V AC/10 - 25 A AC, also for electro-medical instruments • Withstanding voltage to 4000 V • Leakage current 0 - 50 mA • Residual voltage measurement • PC interface (RS-232) + protocol software • Specification of limit value • Acoustic signal for „OK“, „Fault“ and „Warning“ • 700 memory locations • Rugged waterproof case Memory Dimension W x H x D Weight Power supply Case Standard Accessories 700 memory locations 400 x 290 x 130 mm 12 kg External power supply 230 V AC / 50 Hz rugged weatherproff case Cable for measurment of voltage stability, 1 pistol and 1 alligator clip, cable for insulation measurement, cable with 4 alligator clips for low ohms measurement, protokol software and interface cable to connect ALLTEST and PC, calibration certificate Technical data according to EN 60204-1 Withstanding + burn function (BURN) Range (Resolution) 1 kV Accuracy of display ± 5 % ± 20 V 0 - 4 kV 0 - 50 mA (0, 1 mA) ± 2 % ± 2 digits Leakage current Insulation 0 - 99,99 MΩ (10 kΩ) Continuity 0-1Ω (0,001 Ω) Voltage drop measurement 0 - 10 V (0,01 V) Residual voltage measurement: 0 - 10,0 s internal and external Test voltage Test current Test time comments 1000 V AC 0,5 - 500 mA 1s to 10 min 1s to 10 min 1s to 10 min 1s to 15 s Display of test voltage and leakage current, power 500 V A for VDE 0702 0 - 4000 V AC ± 2 % ± 3 digits 500 V DC 2,2 mA ± 2 % ± 2 digits 12 V AC or 6V AC 6 V AC > 10 A or >10 < 25 A AC* ± 2 % ± 0,03 V ± 5 % + 0,1 s limit value 60 V VDE Test Instruments ALLTEST Machine Tester Possibility to adjust a limit value For testing the voltage drop, the wire gauge is selectable: 1-1, 5-2, 5-4 and >6mm2 limit value 1 s resp. 5 s adjustable * by request also deliverable with > 25 A ALLTEST incl. Protocol Software Remote control RCA Mini Printer HT24 Withstanding: High voltage testing 1000 V AC Withstanding testing to 4000 V AC (only ALLTEST) Leakage current (only ALLTEST) 63 PRM-2 Phase Rotation Meter Fast and easy determination of phase sequence in a 3 phase system • Display of phase sequence right or left with LED • Display of the 3 phases with 3 LED • Thermal protection of the tester • CAT III 600 V PRM-2 Voltage range Display Frequency Power consumption Power supply Dimensions W x H x D Weight Safety Standard Accessories 100 … 600 V 5 LED`s 45 Hz to 65 Hz max. 3,5 mA (385 V) from test object 139 x 68 x 28 mm appr. 0,2 kg CAT III 600 V, (EN 61010-1), IP40 incl. 3 test leads, 1 alligator clip and protective case PRM-3 Phase Ratation Meter Fast and easy determination of phase sequence in a 3 phase system • Display of phase sequence right or left with LED • Display of phase voltage loss or sag • Indicates three-phase motor rotation • Low Battery Indication • CAT III 600 V PRM-3 Voltage range Display Frequency Power supply Dimensions W x H x D Weight Safety Standard Accessories 64 50 … 600 V 4 LED`s 45 Hz to 65 Hz 9 V battery 139 x 68 x 28 mm appr. 0,2 kg CAT III 600 V, (EN 61010-1), IP40 incl. 3 test leads, 1 alligator clip and protective case 65 Power Analysis NEW GSC-53 A 3 Phase Power Analyzer and 16th edition Tester in one instrument! • Insulation resistance 50 V, 100 V, 250 V, 500 V, 1000 V DC VDE 0413 part 2/EN 61557-2 • Loop and line impedance, display of short circuit current Ik VDE 0413 part 3/EN 61557-3 • Low ohm measurement with > 200 mA DC VDE 0413 part 4/EN 61557-4 • RCD testing: tripping time, tripping current, touch leakage voltage Ub VDE 0413 part 6/EN 61557-6 • Measurement of earth resistance and ground resistivity VDE 0413 part 5/EN 61557-5 • Phase sequence VDE 0413 part 7/EN 61557-7 Safety standards: The instrument complies with the general safety appointments according to EN 61010-1 (IEC-1010-1), CAT III 600 V for voltage measurement. Display: Graphical – dot matrix Resolution: 128 x 128 (16384 pixel) Visible region: 73 x 73 mm Accessories: Clamp-Ons and adapter for the 3 analog inputs. The transforming ratio for the 3 analog inputs is selectable. Depending on wich Clamp-On is used, the measuring rate can be extended from 5 mA to 3000 A. ACF-3003 A Standard Accessories: The GSC-53 A is delivered incl. carrying case, 3-wire Shuko cable 4 coloured cables (bananabanana), 4 alligator clips, 4 earth rods, 3 flexible current transducer clamp-ons 5 A-1000 A model ACF-1000, 20 m earth measurement set, external power supply A 0050, batteries, management software 2 MB memory, interface cable, manual and calibration certificate. Additional Power Analyzer Function: • Current, Voltage • Apparent power, reactive power, active power, cos ø • Power consumption, energy • Harmonic analysis of voltages and currents • Residual voltage, voltage drops • Voltage peaks Additional Adapter Function: The GSC-53 A is equipped with 3 analog inputs that allows measurement (with adapters) and storage of the following environmental parameters: • Temperature • Humidity • Lux • Noise and Leq (dB) Type 1 Clamp-On accessories GSC-53 A incl. ACF-3003 A GSC-53 A without flexible current transducer 66 Model A-300 + adapter ACF 6 A A 97 + adapter ACF 6 A DMCT-CE ACF-3003 A (flex. 3 phase current transducer) ACF-3000 SR (flex. current transducer) Range from 5 m A AC to 200 A AC from 5 m A AC to 1000 A AC from 5 A AC to 1000 A AC from 5 A AC to 3000 A AC Transforming ratio 1 A/1 V, 1 A/100 mV, 1 A/5 mV from 1 A/1 V to 1 A/1 mV 1 A/1 mV 3 A/1 mV from 15 A AC to 3000 A AC 1 A/0,33 mV (3 A/1 m V) 16th edition (EN 61557), VDE 0100 tests: identical to Genius 80 E (see page 51) Voltage and current measurement Function Voltage measurement Current measurement Range (V) 300, 600 (Autorange) 1 Resolution (V) 0,2 0,001 Accuracy ± 0,5 % of value + 2 digits ± 0,5 % of value + 2 digits Cos 0,20 0,50 0,80 Accuracy ± 1,0 % of value + 2 digits ± 1,0 % of value + 2 digits ± 1,0 % of value + 2 digits Resolution 0,01 digits 0,01 digits 0,01 digits Range DC - 25. harmonic 26. - 33. harmonic 34. - 50. harmonic Accuracy 5 % + 2 digits 10 % + 2 digits 15 % + 2 digits max. Resolution 0,1 V/0,1 A 0,1 V/0,1 A 0,1 V/0,1 A Range 0 - 999,9 W 1 kW - 999,9 kW 1 MW - 999,9 MW 0 - 999,9 VAR 1 kVAR - 999,9 kVAR 1 MVAR - 999,9 MVAR 0 - 999.9 VA 1 - 999.9 kVA 1 - 999.9 MVA 0 - 999.9 WH 1 - 999.9 kWH 1 - 999.9 MWH 0 - 999.9 VARH 1 - 999.9 kVARH 1 - 999.9 MVARH Accuracy Resolution 0.1 W 0.1 kW 0.1 MW 0.1 VAR 0.1 kVAR 0.1 MVAR 0.1 VA 0.1 kVA 0.1 MVA 0.1 WH 0.1 kWH 0.1 MWH 0.1 VARH 0.1 kVARH 0.1 MVARH Input resistance 300 kΩ 100 kΩ Overload protection 900 V (1 min.) 5V Power Analysis GSC-53 A Technical data Cos Measurement (power factor) Function Cos measurement Harmonics Function Harmonics Power Measurement Function Active power Reactive power Apparent power Real consumption (Class 2 IEC 1036) Active energy Reactive energy (Class 3 IEC 1268) ± 1,0 % of measured value + 2 digits Sampling rate: 6,4 kHz, every 20 ms the MAX, MIN and AVG value is recorded. Memory: The GSC-53 A is equipped with 2 MB memory. The recording time is affected by the selected recording rate (5 sec to 60 min) and the number of selected channels (1 - 64 signals). With an interval of 10 sec and 5 selected parameters the max. recording time is 4 days and 8 hours. With an interval of 1 min the max recording time is 26 days. This includes up to 35 recordings/measurements that can be stored. Dimension/Weight: Dimension (W x H x D): 165 x 225 x 105 mm, Weight (incl. batteries): appr. 1600 g Power supply: 6 x battery 1,5 V Type AA LR6, battery lifetime appr. 10 hours, external input 12 Vdc/1200 m A 67 ENERGYTEST 2020 E Handy 3-Phase Power Analyzer • Energy measurement • Power measurement • Harmonics up to 49th • incl. 2 MB memory for long self-powering recording • Accuracy class 2 according to EN 61036 • CAT III 600 V ENERGYTEST 2020 E DMCT-CE The small ENERGYTEST 2020 E is a multi-functional power analyzer for one or three phase measurement and recording of the most important parameters in power supplies, for example: • Voltage • Current • Active power • Waveform voltage • Waveform current • Apparent power • Harmonics of voltage • Harmonics of current • Reactive power • Power factor • Power consumption ENERGYTEST 2020 E is a three-phase power analyser and recorder capable of carrying out a complete analysis of voltages, current and related harmonics, active and reactive powers as well as active and reactive energies. It also permits to analyse the voltage and current harmonic components to check and possibly solve all the problems related to the harmonic presence. Perfect for monitoring computer and power systems as well as: • Testing of the delivered energy • Testing of the voltage quality • Testing and securing a clean operation, e.g. in hospitals or production facilities The transforming ratio for the 3 analog inputs of ENERGYTEST 2020 E is freely selectable. The measuring range can be exceeded from 5 mA up to 3000 A depending on the used Clamp-On. Clamp-On Accessories Model A-300 + adapter ACF 6 A A 97 + adapter ACF 6 A DMCT-CE ACF-3000 SR ACF-3003 68 Range from 5 m A AC to 200 A AC from 5 m A AC to 1000 A AC from 5 A AC to 1000 A AC from 5 A AC to 1000 A AC from 3 A AC to 3000 A AC Transforming ratio 1 A/1 V, 1 A/100 mV, 1 A/5 mV from 1 A/1 V to 1 A/1 mV 1 A/1 mV 1 A/1 mV 1 A/0,33 V and 1 A/3,3 mV Standard Accessories of ENERGYTEST 2020 E: 3 current transducers type DMCT-CE (5 A to 1000 A AC), 4 alligator clips, 4 test leads, external power supply, software, interface cable and carrying case. Voltage and current measurement Function Voltage measurement Current measurement Range (V) 300, 600 (Autorange) 1 Resolution (V) 0,2 0,001 Accuracy ± 0,5 % of value + 2 digits ± 0,5 % of value + 2 digits Cos 0,20 0,50 0,80 Accuracy ± 1,0 % of value + 2 digits ± 1,0 % of value + 2 digits ± 1,0 % of value + 2 digits Resolution 0,01 digits 0,01 digits 0,01 digits Range DC - 25. harmonic 26. - 33. harmonic 34. - 50. harmonic Accuracy 5 % + 2 digits 10 % + 2 digits 15 % + 2 digits max. Resolution 0,1 V/0,1 A 0,1 V/0,1 A 0,1 V/0,1 A Range 0 - 999,9 W 1 kW - 999,9 kW 1 MW - 999,9 MW 0 - 999,9 VAR 1 kVAR - 999,9 kVAR 1 MVAR - 999,9 MVAR 0 - 999.9 VA 1 - 999.9 kVA 1 - 999.9 MVA 0 - 999.9 WH 1 - 999.9 kWH 1 - 999.9 MWH 0 - 999.9 VARH 1 - 999.9 kVARH 1 - 999.9 MVARH Accuracy Resolution 0.1 W 0.1 kW 0.1 MW 0.1 VAR 0.1 kVAR 0.1 MVAR 0.1 VA 0.1 kVA 0.1 MVA 0.1 WH 0.1 kWH 0.1 MWH 0.1 VARH 0.1 kVARH 0.1 MVARH Input impedance 300 kΩ 100 kΩ Overlaod protection 900 V (1 min.) 5V Power Analysis ENERGYTEST 2020 E Technical Data Cos Measurement Function Cos measurement Harmonic Measurement Function Harmonic measurement Power Measurement Function Active power Reactive power Apparent power Active energy (Class 2 IEC 1036) Reactive energy (Class 3 IEC 1268) ± 1,0 % of value + 2 digits ENERGYTEST 2020 is equipped with 2 MB memory. The selected recording rate (5 sec. to 60 min.) and the amount of selected channels (1-64 signals) determine the maximum recording time. Example: With an interval of 10 s and 5 selected parameters the max. recording time is 4 days and 8 hours. With an interval of 1 min. the recording time is 26 days. This includes up to 35 recordings/measurement that can be stored. Safety standards: The instrument complies with the general safety regulations according to EN 61010-1 (IEC-1010-1), pollution degree 2, overload category CAT III 600 V for voltage measurement, for inside operation - max. height 2000 m. Dimensions: Dimension (W x H x D): 165 x 225 x 105 mm Weight (incl. batteries): appr. 1500 g Power supply: 6 x 1,5 V batteries Type AA LR6; battery lifetime: appr. 10 hours External input: 12 Vdc/1200 mA 69 DM-4 Power Quality Recorder NEW The DM-4 addresses the needs of the most demanding Power Quality professionals. The device incorporates full set of measuring features crucial for complete Power Quality analysis. An innovative Remote User Interface (PDA) allows safe, easy and convenient operation of the device remotely. The Remote User Interface (PDA) is also used for data viewing, analysis and transfer. Independently, the DM-4 can be used directly with the PC type of computer. Since the DM-4 does not have any control buttons on its enclosure, it is protected against setup changes by unauthorized persons while the device is recording. Benefits of remote control user interface PDA: This approach gives user a convenience of a wireless connection via infrared port or bluetooth a full remote control of the device. Increased safety of a user. Safety: Since the PDA is connected remotely to the recorder using wireless transmission, user is fully isolated from the electrical system. This way the safety of the user is significantly increased against dangerous over-voltage or other sources of electric shock. Portable data transfer medium: The PDA can be used as a portable medium for downloading data from DM-4 and transfering to stationary PC in order to generate reports. 70 • True RMS (TRMS) • Extremely easy to setup and operate • Comes as a complete kit: carrying case, CTs, test leads, PC software & download cable, Remote User Interface (PDA) w/ protective hard case and interface cable are included with product • Rugged Remote User Interface with memory for easy data downloads in the filed and increased safety • Works with single (two and three wire) and three phase systems (Y and Delta) • Detects and records voltage spikes 100 ns or slower • Detects and records voltage Sags and Surges • Built in scope displays waveforms • Records all parameters (single or three phase) simultaneously • Manual and programmable recording start • Selectable fundamental frequency of 50 or 60 Hz • Special data compression system and user selectable rates allow recording from several hours to several years • Download capabilities with PC (Windows compatible software) or PDA (Palm OS) • Line or battery powered • Safety: CATIII, 600 V NEW Power Analysis DM-4 Power Quality Recorder For more detailed specification visit www.amprobe.co.uk Technical features Features Supplied Current Transducer AC Current AC Voltage including Sags and Surges Voltage Transients Harmonics (Voltage and Current) Power Energy Peak Demand Power Factor (True and Displacement) Phase sequence Selectable Fundamental Frequencies Available Recording Time Memory Power supply Weight Size Operating temperature DM-4 1000 A Standard CT, 2” internal diameter CT Standard: (5 - 1000 A ) Optional: For more CT options visit www.amprobe.co.uk From 20 V - to 1000 V 200 - 6000 V pp, Duration > 100 nS THD, DC and individual up to 51th Working (W), Reactive (VAR) and Apparent (VA) Working (kWh), Reactive (VARh) and Apparent (VAh) KW 0.00 - 1.00 1-2-3 50/60 Hz Several hours to several years depending on setup 8 MB 8 x 1,5 V (AA), external: 12 V 800 g 116 x 242 x 72 mm 0° - 50°C, relative humidity < 95% Standard Accessories (supplied with product) Remote User Interface (PDA) with connection cables 1000 A Clamp (3 pieces) Soft Carrying case External power supply 12 VDC Test leads and alligator clips (set of 4) PDA/DM-4 Interface Cable RS-232 Computer Cable PC Windows Software Palm OS Software Instruction Manual Part Number Recommended Tungsten E2 DM-CT-CE HW1254A DM-4 EXTPS-E KITENERGY3 RS-PDA MVK-2000S www.amprobe.co.uk www.amprobe.co.uk www.amprobe.co.uk Optional Accessories 1 - 100 A Current Transducer & Adapter 5 mA - 200 A Current Transducer & Adapter 3000 A Flexible Current Transducer Remote User Interface protective case USB-RS-232 Adapter Part Number DM-CT-100 A-300 + ACF-6A ACF-3003 DM-4 CASE RS-USB Adapter Accuracy Input accuracy: +/- (2% Rdg + 2 LSD) +/- (3% Rdg + 2 LSD) +/- 10% Rdg +/- (5% Rdg + 2 LSD) @ DC to 25 harmonics +/- (3.0% Rdg + 2 LSD) +/- (3.0% Rdg + 2 LSD) +/- (3.0% Rdg + 2 LSD) +/- 3% 71 DM-II 3-Phase Power Analyzer The new Data Logger/Recorder allows to directly display the efficiency of the electrical system or record it over a period of several months. Stored data can be downloaded to a PC for analysis and report generation. • Selection of display or record 1-60 days, depending on the interval 1 s, 5 s, 15 s, 30 s, 1 min, 15 min or 30 min • Intuitive, very easy to use interface + Windows analysis and documentation software • Line or battery powered • Incl. protective case, test leads, 4 transducer Clamp-Ons 1000 A and Windows software • 1 or 3 phase measurement (Wye and Delta) • Voltage 0 to 600 V AC • Current 0 to 1000 A AC, (3000 A optional) • True RMS measurement • 8 channels: 4 for voltage and 4 for current • Matrix display 160 x 160 pixel • Power measurement: W, Var, VA and cos • Energy measurement: kWh, kVAh, kVar • Real time clock • 640 kB memory • rugged water-proof case Screenshot of DM - II Windows-Software Special functions • Voltage and current measurment: True RMS, MAX, MIN, AVG, PEAK • Power measurement: Active, reactive, apparent power, power factor cos • Energy measurement: kWh • Five built in languages: English, German, Spanish, Italian, French • Memory: The maximum recording time (automatically displayed) depends on the recording rate, the number of parameters, the recording mode and the recording interval. The memory is protected by a lithium battery from data leakage by voltagedrop of power supply General Data Inputs 4 voltage channels with common (V1, V2, V3, COM) 4 current channels (I1, I2, I3, I4) Range True RMS 5 to 600 Vrms AC AC Current (TRMS) 1 to 1000 A with included current Clamp-Ons Accuracy Voltage measurement ± 1 % of reading Current measurement ± 1 % of reading Time Real-time-clock, format: hh:mm:ss day, month, year, accuracy ± 1 min per month System configuration A total of 4 setup configurations for 1 and 3 phase systems can be selected. (Wye and Delta circuits) PC Interface Power supply Sample rate Grafic display Case Dimension W x H x D Weight Batteries Operation conditions Storage conditions Serial RS-232 interface. DM-II software, for analysis and report generation Line voltage with additional battery back-up (green=AC line power and red=battery back-up) selectable 120/240 V and 50/60 Hz 156 μs (6,4 kHz), 128 measurements per cycle Resolution 160 x 160 pixel, contrast adjustable, backlight ABS911 flame retardant, water resistant and corrosion proof 295 x 45 x 191 mm 7,3 kg 6 alkaline „D“ cells 0 - 50 °C, RH <85 % -2 to 60 °C, RH <85 % DM-II 72 73 Wire Tracer/Wire Location AT-2000 Advanced Wire Tracers For Buildings, Industry and Outdoor Installations Fast and easy fault clearance at lowest expenditure and time exposure. AT -2000 • Traces and locates live wires buried or hidden behind walls, ferroconcrete and underground cables in up to 2,5 m depth • Does not interfere with sensitive electronic equipment • Locates wires in ceilings, walls and floors • Pinpoints shorts, ground faults and broken wires • Locates breakers, neutral and ground lines • Allocation of fuses and electric circuits • Tracing heat and water pipes With the wire tracer of the AT-2000 family energized and unenergized lines (up to 600 VAC and VDC) can be located easily, without interrupting power or turning-off sensitive electrical equipment. Complete Kits The AT-2000 family wire tracers are based on a module system. Combination for your application: Energized wires to 300 V AC/DC Energized wires to 600 V AC/DC Unenergized wires (broken or disconnected) Receiver R 2000 Load Signal Generator / Transmitter S 2300 S2600 T 2200 Configuration Case-Set AT-2001 AT-2002 AT-2003 Energized wires to 300 V AC/DC + unenergized wires (broken or disconnected) AT-2004 Energized wires to 600 V AC/DC + unenergized wires (broken or disconnected) AT-2005 The load signal generators permit a reception of the signal for 2 km cable length. The sensivity of the receiver R2000 can be selected continuous variable from 1 to 1000. A display of 10 LED's indicates the exact course of the cable accurate to a centimeter. Thanks to the configuration of different load signal generators you will get the perfect wire tracer for your special demands. 74 Accessories on page 106 ATGC-1 Ground Coil R-2000 Receiver • Traces and locates buried conductors like Main Electrical Feeds, Water Mains, Telephone Lines, etc. • Up to 2 m depth and 100 m range • Eliminates direct connection of transmitter • No access to the conductor required Wire, water pipe or gas pipe ATGC-1 Diameter (coil) Range Connector Weight Electromagnetic signal (32 kHz) 1m 100 m banana connectors for T-220 700 g The ATGC-1 Ground Coil allows the signal from the T-2200 Transmitter in the Advanced Tracer AT-2000 series to be induced onto buried conductors, water pipes and gas pipes up to 2 m deep. The coil is placed on the ground, above and to the side of the conductor to be traced. This allows tracing of conductors up to 100 m in length. With the receiver R-2000 a underground cable can be located and traced. The Battery Booster B-2024 can be used to ensure a maximum transfer of the signal. Wire Tracer/Wire Location T-2200 Transmitter ATGC-1 Advanced Tracer Ground Coil B-2024 Battery Booster AT-2000 The Module-Based Wire Tracing and Location Instrument R-2000 S-2300 S-2600 T-2200 R-2000 The R-2000 receiver has two detectors in its tip which are tuned to pick up the electromagnetic signals ("short" mode) or electrostatic signals ("open" mode) generated by the other components. The LED's and sensitivity settings indicate the relative signal strength to allow easy detection of the signal source. The R-2000 is included in each of the five systems: AT-2001 through AT-2005. S-2300 S-2600 T-2200 Technical Data R-2000 Sensitivity Selection Power supply Display Case Weight x 1, x 10, x 100, fine adjustment 0 - 10 9 V alkaline battery 10 LED´s with chroma filter lens Flame retardant ABS 911 176 g with battery Technical Data Signal Generator Function Operating voltage Signal output Duty Cycle Power consumption Power supply Fuse Case Weight S-2300 9 - 300 V AC/DC 32,768 kHz 2 pulses/0,5 s duration: 62,5 ms 4 mA (low) 6 mA (high) of supply voltage 250 mA/380 V (6 x 32 mm) fast acting flame retardant ABS 911 108 g S-2600 9 - 600 V AC/DC 32,768 kHz 2 pulses/0,5 s duration: 62,5 ms 4 mA (low) 6 mA (high) of supply voltage 250 m A/660 V (6 x 32 mm) fast acting flame retardant ABS 911 108 g T-2200 9 V or 24 V supply 32,768 kHz 2 pulses/0,5 s duration: 63,5 ms max. 500 mA (AVG) at 24 V 9 V battery or 24 V accumulator 2 A/250 V (6 x 32 mm) fast acting flame retardant ABS 911 182 g 75 AT-2000 Accessories Clamp-On attachment A-2201 Plugged into the T-2200 and clamped around an energized line, it will induce a signal onto the downstream to enable identification of equipment on that circuit. Max. cable diameter: 55 mm Case braekdown voltage: 3 kV 24 V high performance rechargeable battery B-2024 + recharger B-2025 for boosting the output of the transmitter T-2200 A-2201 Carriyng Case small CA-200 A-2201 Carrying Case big CC-2000 Test leads EU-200 B-2025 B-2024 ATGC-1 B-2025 + B-2024 AT-1000 The Intelligent System The advanced tracer for electrical applications Finding is better than Searching AT-1000 The line and cable tracer AT-1000 permits a secure location of unenergized and energized cables. Tracing is possible without powering down the system or turning-off sensitive electrical equipment. • Trace energized lines up to 300 VAC or VDC • Trace unenergized and open conductors • Locates shorts • Identifies breakers and fuses without powering down • Identifies control, alarm and telephone system wiring • Traces coaxial cable shield Receiver R 1000 Display Range selction Power supply Power consumption Weight 4 LED’s sensivity x 1 - x 2 - x 3 - x 4 - x 5 9 V battery IEC6 LR61 33 mA max. 151 g with battery Operation temperature Storage temperature Case Standard Accessories AT-1000 - 20° C + 50° C - 40° C + 65° C ABS 911 flame retardant R 1000 + X-1000 + test leads EU 200 + battery + case The AT-1000 includes a Receiver and a transmitter. The transmitter injects a signal into the conductor. The receiver picks up this signal and displays it by acoustic and optic signals (LED's). AT-1000 76 The advaced cable tracer AT-3000 is perfect for fast and easy location of underground cables, buried wires and pipes. Three testing modes for best accuracy. In the P mode (50 Hz - 3.5 kHz) the R-3000 detects power signals that are being radiated by loaded cables. In the R mode (15 kHz - 30 kHz) the R-3000 detects radio signals re-radiated by buried metallic pipes and cables. In the G mode (32.768 kHz) the R-3000 detects a tone radiated by the G-3000 signal generator to a buried conductor. Wire Tracer/Wire Location AT-3000 The Wire Tracer The signal of the targent is indicated optically and acoustically. Depth measurement is activated by pressing the depth button. AT-3000 Features: • Locating of cables, metallic lines and water pipes • Depth measurement up to 3,5 m • Pinpoint the path of the traced object over 500 m • Complete instrument, ready for use with receiver, transmitter, connection cable and ground stake • Optical and acoustical indicator (detachable speaker) • High sensivity • LCD display • Incl. carrying case Advantages: • Exact indication of the depth of traced object (pipe or cable) • Allround area of application • Energized lines tracing • Unenergized lines tracing • Easy to use • Weatherproof and drop resistant (IP-54) • Eliminates exploratory digging in parking lots or under floors for buried pipes and wires • Three testing modes for best accuracy Userguide/Helpful Hints see page 111 - 114 77 AT-3000 The Wire Tracer Standard Accessories: Receiver R-3000, transmitter G-3000, connection cable set CK 3000, carrying case SV 3000, manual Technical Data Location Accuracy Depth accuracy with undistorted signal ± 10% of depth -5% 0,3 m to 2 m -10% 2 m to 3m with signal mouse -7% 0,5 m to 3 m -15 % 3 m to 5 m Optical indicator LCD display, indicates following values: Operation mode, signal strength, cable depth, probe depth Acoustic indicator Acoustig signals through waterproof loudspeaker Loudspeaker is detachable for use as headphone in noisy environments External voltage protection Output circuit is protected against overvoltage 230 V, 50/60 Hz Low Battery indicator Continuous beep indicates sufficient battery capacity 1Hz pulse beep indicates required battery change Signal 32.768 kHz continuous (G-3000) Output current 0,12 W automatic impedance adjustment Protection class shock EN60068-2, dust and water IP 54, drop EN60068-2 Function Weight Dimension Batteries Average operating time Operation temperature Receiver R 3000 2,2 kg 720 x 55 x 65 mm 8 x LR6 (AA) 1,5 V > 40 hours -20° C to +50° C Transmitter G 3000 2,5 kg 280 x 175 x 210 mm 4 x LR20 1,5 V > 30 hours -20° C to +50° C SC-3000 Optional Accessories: Signal clamp Ø 100 mm (SC-3000) Signal Mouse (M-3000) Live plug connector 230 V (LC-3000) M-3000 LC-3000 Userguide/Helpful Hints see page 111 - 114 78 Handheld Reflectometer (TDR) for cable fault location Measurement of cable length • Easy single handed operation for long and short range fault finding • LEXXI T 810 gives genuine universal performance for short and long range applications on all types of metallic cable, with switchable settings for CATV, 75 Ohm coax, datacom and telecom twisted pair, LV power distribution and 50 Ohm coax. • Large back-it display, tactile push buttons and ability to operate in temperatures as low as -20°C allow use in a vast range of locations and conditions • Innovative features result in a versatile, cable-test instrument that is easy to use and accurate to 20 cm on shortest range • Automatic cable attenuation compensation ensures easy location of faults at all distances, without the need for a balance control. Wire Tracer/Wire Location LEXXI T 810 Reflectometer Technical Data Range (nominal) Accuracy Resolution Propagation velocity Output impedance Output Protection Display Noise suppression Power supply Operation temperature Dimension W x H x D Weight 10 m, 30 m, 300 m, 1000 m, 3000 m at a pvf=0,67 +/- 0,9 % v. range 1 % of range Variable velocity factor 0.2 to 0.99 pvf, unit remembers last figure used. 25 Ω, 50 Ω, 75 Ω and 100 Ω switchable 2 x 4 mm on 19 mm pitch Instrument will not be damaged by direct application of 250V AC rms 50/60 Hz to the input. For safety reasons, however, it should NOT be operated under these conditions. For safe use on cable carrying hazardous live voltages, the fused blocking filter test lead MUST be used. Gaphical LCD, 128 x 64 pixels with back light Average value over 4 measurements 6 x AA LR6 alkaline batteries -20 °C +55 °C 250 x 100 x 55 mm 0,6 kg with batteries, without test leads LEXXI T 810 LEXXI, weather proof carrying case, batteries, manual, without test leads L 810/1/PWR Fused blocking filter test lead for live AC power cable. Maximum voltage 600 V rms, 50/60 Hz L 810/1/50 50 Ω test lead for coax cable and unenergized power cable L 810/1/75 75 Ω test lead for coax cable L 810/1/100 100 Ω test lead for twisted pair cable 79 TDR-400 Impulse Reflectometer The TDR-400 is a handy, light impulse reflectometer, processor controlled, with LCD display for check and locate faults in telecommunication and power cables. Measuring principle: The measuring pulse fed into the cable will reflected by in homogeneity of the cable impedance (cable faults) and showed on the display. The distance and the kind of the fault can be determined out of the shape and the time setting of the reflection. (Practical experience can be obtained by test measurements). If the cable is terminated with a resistance equal to the impedance of the cable, no reflexion occurs when the cable is faultless. In the case of breaks, contact faults in sleeves, short circuits or taps/splitter in the sector to be tested, the distance to the cable beginning can be determined by the pulse echo. If wide pulses are used for the measurement, the echoes are stronger, but faultless taps/splitter cause then strong echoes. Propagation factor The Propagation factor (nvp-value) declares the velocity of electrical signals in the cable in relation to the speed of light. The propagation factor of the cable under test must always preset before the length measurement. If the propagation factor is unknown, a approximate value is set and the fault is determined from both ends of the cable Measuring range Resolution Accuracy Propagation factor Storage places Dynamics Impedance Output Output pulse Operating Display Power supply Power consumption Dimensions Weight 0 - 2000 m 0.25 m, 0.5 m, 1 m, 4 m 0.2 % of the measuring range 0.25 to 0.999 10 for propagation factor 44 dB 75 Ohm F-socket 4 V/5 ns or 100 ns with 3 keys LCD display, 120 x 32 pixel, illuminated NiMH accumulator 6 V/ 700 mAh (5 x R3), 80 mA 157 x 84 x 30 mm 300 g TDR-400 80 81 Temperature-Climate-Environment TH-2A Temperature and Humidity Probe • For industry, laboratories and hospitals • Temperature measurement in °F or °C • Humidity measurement (relative humidity R%) • MIN and MAX storage with time indication • Auto power off • DATA HOLD • Dual LCD display TH-2A THWD-2 The Universal Genius Measurement of air conditions and dew point as TH-2A, additionally: • Dew point measurement • Wet Bulb reading • Memory for 99 values THWD-2 Technical Data THWD-2, TH-2A Instrument Temperature range Accuracy Resolution Humidity range Accuracy Memory Sampling rate Weight Battery Dimension W x H x D 82 THWD-2 -20° C - +60° C (-4 - +140° F) ± 0,8° C (± 1,5° F) 0,1° C / 0,1 % RH 1 - 99,9 % RH ± 3 % @ 25° C to 10 - 90 % RH 99 values 2/Sec. 100 g 3 x 1,5 V AAA/200 h 170 x 46 x 20 mm TH-2A -10° C - +60° C (+14 - +122° F) ± 1° C (± 1° F) 0,1° C / 0,1 % RH 1 - 99,9 % RH ± 3 % @ 25° C to 10 - 90 % RH 2 values 2/Sec. 100 g 3 x 1,5 V AAA/200 h 170 x 46 x 20 mm • rugged plunge probe of stainless steel • Durable case includes a cover to protect the probe • Temperature measurements in °C or °F -40 °C to + 200 °C / -40 °F to + 390 °F • DATA HOLD • Water resistant • Shock proof • Auto power off after 3 minutes RA 43240 DT-130 Digital Thermometer Temperature-Climate-Environment RA 43240 Digital Thermometer The cost-effective and rugged digital thermometer DT-130 is perfect for temperature measurement in daily applications of industry and handcraft. • 3 1/2 digit LCD display • 1 channel Type K thermometer • Resolution 0.1 °C or 1 °C switchable • MAX hold function • DATA HOLD • Range from -50 to + 1300 °C • Accuracy ± 0.3 % ± 1 °C • °C or °F selectable • incl. flexible thermocouple 0,5 m (-50 °C ... +204 °C) • Low battery indicator • Analog output: 0,1 mV resp. 1 mV/°C • Power supply: 1 x 9 V battery • Dimension: 77 x 160 x 43 mm • Weight: 235 g DT-130 DT-136 Digital Thermometer The universal digital thermometer DT-136 records the temperature values of 2 thermocouples and displays them separately or as difference on the clear display. • 3 1/2 digit LCD display • 2 channel Type K/J thermometer • Differantial temperature reading (T1-T2) • Relative zero mode • Resolution 1 °C • MIN and MAX recording • DATA HOLD • Range -50 to +1300 °C • Accuracy ± 0,3 % ± 1 °C • incl. thermocouple 0,5 m (-50 °C ... +204 °C) • °C or °F selectable • Low battery indicator • Power supply 1 x 9 V battery • Dimension: 77 x 160 x 43 mm • Weight: 235 g DT-136 83 LT-100 Infrared Thermometer Fast and easy noncontact temperature measurement by innovative infrared technology • LCD display with backlight • Response time 0,5 sec • Range from -35 °C to +500 °C • Single point laser for indication of target spot • Audible and visual alarm Dimension W x H x D Power supply Weight Range 46 x 172 x 118 mm 9 Volt battery 220 g incl. battery -35°C to +500°C • Measurement distance in proportion to target area 6:1 • Pinpointing temperature differences, overheating of fuses, contacts, switches and lines • Adjustable emission ratio • Memory for 50 measured values Resolution 0,1°C Accuracy +2°C resp. ± 2% Standard Accessories incl. battery ST-20 Infrared Laser Thermometer Fast and easy noncontact temperature measurement by innovative infrared technology • LCD display with back light • Measurement distance in proportion to target • Max. temperature indication on display area 12:1 • Response time 0,5 sec • Pinpointing temperature differences, overheating of fuses, contacts switches and lines • Range from -32 °C to +400 °C • Measuring tempereature from a safe distance of high • Automatic DATA HOLD for 7 sec • Single point laser for indication of target spot voltage facilities, transformators and rotating machines Dimension W x H x D Power supplyg Weight 41 x 160 x 111 mm 9 Volt battery 320 g incl. battery Standard Accessories incl. battery and carrying case Range -32° C to +400° C Resolution/Accuracy 0,2° C/< ± 1° C resp. ± 0,5 % TMA-K Temperature Adapter for Digital Multimeters Extends the possibilities of you multimeter to measure temperatures from -50 °C to 1000 °C • Voltage output 1mV DC/per 1°C • incl. TPK-56 K-Type thermocouple (-50 °C - 240 °C) Dimension W x H x D Battery lifetime 46 x 122 x 30 mm appr. 500 hours with alkaline 9 V rechageable batteries • Range can be extended up to 1000°C by using any poperly rated K-Type thermocouple Weight 60 g incl. battery Standard Accessories incl. battery and thermocouple Typ TPK-56 (-50 to +240° C) TL-10 S Test Lead Extension for TMA-K Permits a free mobility of the thermocouple TMA-K at connection with a multimeter. 84 • T10 Mono-K-Temperature Adapter with banana plugs 4 mm • TAC-DMM Mono-K-Temperature Adapter with banana plugs 4 mm • DKTA-620 Dual-K-Temperature Adapter with banana plugs 4 mm DKT-620 T10 TAC-DMM TAC-DMM T10 DKTA-620 K-Thermocouples TC-11 DPX-2000 TPK-56 Temperature-Climate-Environment K-Temperature Adapter TC-12 TPK-59 TC-13 TC-11 TC-12 TC-13 TC-14 Model TC-11 TC-12 TC-13 TC-14 TPK-56 TPK-59 DPX-2000 Function Liquidity probe Surface probe Air/Gas probe Hypodermitc probe Bead K-type thermocouple (0,5 m) Bead K-type thermocouple 4 mm (0,5 m) Thermocouple extension cord (1 m) Range - 60° C to 1092° C - 60° C to 1092° C - 60° C to 1092° C - 60° C to 1092° C - 50° C to 204° C - 50° C to 204° C Accuracy ± 1,5 % ± 1,5 % ± 1,5 % ± 1,5 % ± 1,5 % ± 1,5 % TC-14 TPK-56 TPK-59 DPX-2000 LM-80 Digital Light Meter with Analog Output • 4 ranges from 0,1 Lux to 20.000 Lux • Selection of Lux or fc (footcandle) • Peak Hold • Data and Peak Hold function • Manual ranging • Silicon Sensor • Analog DC Voltage output to operate with a Chart Recorder or Data Logger • incl. carrying case and battery Display Function Dimension W x H x D Weight Power supply Standard Accessories LCD, 3 1/2 stellig Range Resolution 0 … 20 Lux 0,1 Lux 0 … 200 Lux 1 Lux 0 … 2000 Lux 10 Lux 0 … 20000 Lux 100 Lux 72 x 135 x 33 mm (Instrument), 60 x 100 x 27 mm (Sensor) appr. 280 g 9 V battery, IEC 6LR61 for appr. 200 h lifetime incl. carrying case and battery Analog output 1 mV DC /0,1 Lux 1 mV DC /1 Lux 1 mV DC /10 Lux 1 mV DC /100 Lux LM-80 Accuracy ± 3 % of value ± 0,5 % of value ± 4 % of value ± 10 digits from 10000 Lux 85 TMULD-300 Ultrasonic Testmaster Kit Ultrasonic sound is a range of sound (> 20kHz) that is above the human hearing capacity. Turbulence created by air or a gas forced through a small orifice generates ultrasonic sound. The ULD-300 Ultrasonic Leak Detector is designed to locate the source of ultrasonic sound emissions and leads you directly to the leak. The ULD-300 has an optical (10-LED-scale) and acoustic indicator (earphone) as well as a thumb weel for sensivity selection. Locating of: • Tire and tube leaks • Leaks in refrigeration and air conditioning or heating systems • Leakage of door and window gaskets or roofs • Leaks in automotive areas: windscreens, door gaskets TMULD-3000 includes all accessories that are necessary to locate a wide range of leakage. Standard Accessories • Ultrasonic Leak Detector ULD-300 • Ultrasonic Transmitter UT-300 • Earphone • Extenstions + Parabola adapter • Carrying case Model Frequency Response Power Consumption Dimension W x H x D Battery Life Weight ULD-300 Ultrasonic Leak Detector ULD-300 35 kHz to 45 kHz ± 6 dB 22 mA at 9 V DC 65 x 185 x 25 mm 33 hours with alkaline 9 V battery 150 g incl. battery TMULD-300 UT-300 40 kHz 8,5 mA az 9 V 65 x 165 x 25 mm 60 hours with alkaline 9 V battery 160 g incl. battery Receiver ULD-300 Receiver ULD-300 Transmitter UT-300 Transmitter UT-300 ULD-300 Locating leakage of a door UT-300 Ultrasonic Transmitter Receiver ULD-300 In areas where leaking gases are not sufficiently pressurized, there is no ultrasonic sound for detection. This instrument will allow ultrasonic detection where it would not normally be possible. UT-300 86 Locating leakage of window frames Receiver ULD-300 Transmitter UT-300 Transmitter UT-300 Locating leakage of a roof Locating leakage of a windscreen 87 Test and Measurement Tools VP-440 Volt Probe Non-Contact Volt Probe • Locating of circuit breakers • Voltage range: 110 - 600 V AC • Locating of defective fuses • No disconnection of electrical system necessary • Uses non-contact method of Voltage testing • Test for AC Voltage cables, wall sockets, junction boxes, etc. VP-440 The Volt Probe 440 resp. VP 500 can be used to securely detect AC Voltage on cables, wall sockets, fuses, switches junction boxes, etc. It is not necessary to disconnect the electrical system for a proper mode of operation. If Voltage is detected, the white plastic tip will glow. Incl. batteries VP-600 Non-Contact VoltProbes ® • Detect AC Voltage (100 - 600 V) • Use non-contact method of Voltage testing • Totally insulated, no exposed metal or conductive parts • Check for AC Voltages without necessity of Disconnecting the electrical system • Test for AC Voltage cables, circuit breakers, wall sockets, junction boxes, fuses, etc. • Safety CAT III 600 V Features AC Voltage Detection Visual Indication Voltage Buzzer Voltage Shaker VP-600 100 - 600 V • VP-600 VP-600B VP-600SB VP-600B VP-600SB • • • • • MT-1000L Magnetic Tester • Non-contact magnetic field tester with torch function • Build-in magnetic field sensor enables magnetic fields to be detected • The test tip lights up immediately without any metal contact as soon as a magnetic field is detected • The test lamp reacts to all magnetic fields in three-phase current, direct current and permanent magnets. • Testing of Solenoid Valves • Ultrabright LED • incl. Test Magnet and Batteries MT-1000L 88 LSP-2 Test and Measurement Tools Volt Probe with solar cell and lithium battery • Volt Probe according to VDE 0682 part 401 for 12 - 690 V AC/DC • 2-Range Continuity Check 200 kΩ and 3 MΩ • Phase rotation • Phase determination • Polarity indication • Power consumption ≤ 30 mA (3,1 mA to 690 V) • 9 LEDs for voltage, continuity check, phase and phase rotation • Continuity check 0,2 ... 3 MΩ (blinking) • No battery required • CAT IV 690 V The lithium battery enables a long lifetime for continuity checks and phase- and phase sequence indication. The rugged case is shock-resistant, dust and waterproof (IP65). LSP-2 W-GT 1 Tool Belt Standard Accessories: Clamp-On Multimeter Non-contact Volt Probe Screwdriver Multifunction Pocket Knife Tool Belt - ACD-10 Pro AM-220 VP-440 CVF-3 MTM-1 GT-100 89 Multitest Voltage Tester Voltage and continuity tester with phase rotation. • 12 V to 690 V AC & DC voltage range • Continuity test (optical + sound) • Phase rotation test • Polarity indication • Phase testing C AT • Data Hold function • 30 mA FI/RCD-trigger test • PE-Test • undetachably tip protection • IP65 water jet and dust tight protection • TÜV approved/CATIV 1000 V Display: Rated voltage range Frequency range Test current Continuity test Degree of protection Overvoltage category TÜV/GS tested Power supply 10 red LEDs for voltage (12, 24, 48, 120, 230, 400 and 690 V), Polarity (+~-), continuity (Rx/Ohm) and p hase/rotating field (L1>) 12 ... 690 V AC/DC 0 ... 400 Hz ~ 30 mA 0 ... 500 kOhm IP65 CAT IV 1000 V IEC/EN 61243-3 2 x 1,5 V type AAA Micro Quick single hand test on 19 mm contact distance outlets Full-scale picture 90 V IV 1000 undetachably tip protection Multitest Protective Case CC-ACDC Voltage Tester Voltage and continuity tester with phase rotation. • LCD Display with backlight • 12 V to 690 V AC & DC voltage range • Continuity test (optical + sound) • Phase rotation test • Polarity indication C AT • Phase testing • Data Hold function • 30mA FI/RCD-trigger test • PE-Test • Automatic Backlight • undetachably tip protection • IP65 water jet and dust tight protection • TÜV approved/CATIV 1000 V Display Rated voltage range Frequency range Test current Auto power off Continuity test Degree of protection Overvoltage category TÜV/GS tested Power supply 3 1/2 digit, back light LC display + 1-digit LC display 12 ... 690 V AC/DC 0 ... 400 Hz ~ 30 mA 0 ... 2 kOhm IP65 CAT IV 1000 V IEC/EN 61243-3, DIN VDE 0682-401 2 x 1,5 V type AAA Micro Quick single hand test on 19mm contact distance outlets Full-scale picture V IV 1000 Test and Measurement Tools Digital undetachably tip protection Digital Protective Case CC-ACDC 91 KWIK-I-E Non-contact Measurement The new Non-Contact Volt- and Amperemeter for fast and easy non-contact measurement. • fast • easy • safe • Non-contact measurement on single lines • No unisolation or disconnection of conductors • Measurement of Voltage and Current • Bar graph (10 Segment) • Two ranges (high/low) • Fits in every tool bag • Helpful in most of measuring situations • User-friendly and safe • Cost-effective Technical Data Weight Dimension Voltage range Current range Accuracy Accessories 80 g 179 mm x 38 mm x 26 mm 6 - 60 VAC and 60 - 600 VAC 0,6 - 6 AAC and 6 - 60 AAC up to +/- 15 % of full scale Carrying case CC-K-1 KWIK-I-E Full-scale picture 92 Carrying case CC-K-1 Leak Detectors HIGH SPEED HIGH QUALITY 93 HIGH SPEED – HIGH QUALITY MINIMAX-E TIF ZX-1 E small, light and ergonomic “Heated PentodeTM” Refrigerant Leak Detector The new generation, digital handheld leak detection system. PROMAX RG 5410A-E Filter and tip oil-less high pressure refrigerant recovery system MINIMAX-E • developed for e.g. R 410a dumping applications • High pressure dumping up to 38 bar • 250 x 222 x 406 mm PROMAX RG 5410A-E • developed for e.g. R 410a dumping applications • High pressure dumping up to 38 bar • 343 x 229 x 483 mm • eliminated false alarms by temperature change, humidity, purifier, lotions etc. • 40 cm (16") Flexible Stainless Probe ROBINAIR TIF 9010A Vacuum pump Model 15401 “Slimeline” Refrigerant Scale • it allows the technician to locate smallest leaks without giving false alarm • Detects ALL Halogenated refrigerants, including R410A Two-step high performance vacuum pump • Capacity 93 l/min. • No. of Stages 2 • Endvacuum 20 Mikron • Intake Fittings UNF 1/4” MFL + 1/2” MFLT • Oil Capacity 15 oz (445 ml) 94 • Motor Size 1/3 HP (244 W) • Power Supply 110 V, 60 Hz/ 220 V, 50 Hz • Weight 26,4 lbs (12 kg) • Dimensions 247 x 142,5 x 381 mm • Touch Key controls • display kg, lbs/oz; Decimal lbs • Very High Resolution - 2 grams • Extreme Accuracy • 50 kg/110 Pound capacity • Auto Zero • Removable platform, control box with prop stand/hanging hook • Compact design, portable • Can be used with all refrigerants • Compatible with TIF 9020 • CE approved Heated Pentode Refrigerant Leak Detector • Detects leaks of Sulfur Hexafluoride (SF6) used as a dielectric and insulator in: - High voltage breakers - Gas insulated substations (GIS) - Cables and tubular transmission lines - Electrostatic generators and transformers • Detects leaks of all Halogenated refrigerants in HVAC systems - Detects leaks at levels below 0.1 oz/yr - Eliminates false alarms from moisture, cleaners, solvents, etc... - Sensor can not be poisoned by excessive refrigerants • Tri-color visual leak size indication • One touch reset • Adjustable sensitivity • True mechanical pump provides instant response and clearing • Automatic constant battery and sensor monitoring • Ni-cad rechargeable batteries • Certified to SAE J1627, CE approved • Made in the USA lows the technician to locate allest leaks without giving e alarm ects ALL Halogenated gerants, including R410A Leak Detectors TIF ZX-1E Optional Accessories: • 230 V 50 Hz Battery charger (TIF ZX-3E) • Remote battery charging base (TIF ZX-6) • Nickel-Metal Hydride (NiMH) Battery Pack (TIF ZX-7) • Battery charger 12V (Cigarette lighter) (TIF ZX-11) • Carrying Case (TIF ZX-5) • Nickel cadmium (Ni-Cad) Battery pack (TIF ZX-4) Specifications Sensitivity Ultimate Sensitivity Warm-up period Operating Temperature Power Supply Battery recharge time Failed sensor indication Sensor life Battery life Dimensions Weight Per SAEJ1627 Criteria: 14 gr/yr (0.5 oz/yr) for R134a, R22 and R12 Less than 3gr/yr (0.1 oz/yr) R134a, in high sensitivity; as low as 0.05 oz/yr R12 in low sensitivity. 20 seconds 0° to 50°C (32° to 122°F) Ni-Cad standard, NiMH optional 2 hours, integral charge status indicator All LED's flash red, pump off 100 to 150 hours Standard Ni-Cad battery pack - 4 to 5 hours; optional NiMH battery pack - 5 to 6 hours 26cm Length x 6.5 cm Diameter (10.25" L x 2.5" Dia.) Approximately 452 grams (16 ounces) 95 TIF XL-1A / TIF RX-1A / TIF XP-1A Refrigerant Leak Detectors • Microprocessor controlled circuit with Advanced Digital Signal Processing • Detects ALL Halogenated refrigerants • Certified to SAEJ1627 • Variable frequency audible alarm • CE Approval • UL Classified • Constant Power Indication • Cordless and portable, operates on 2 C-cell batteries • 35.5 cm flexible stainless steel probe w/ Teflon liner • Carrying case included, optional holster • Optional reference leak source TIF XL-1A TIF RX-1A TIF XP-1A Optional Accessories/Replacement Parts: • Maintenance Kit (3 Tips, 3 Protectors) (TIF XP-2) • Carrying Holster (TIF XP-3) • Deluxe Carrying Case (TIF XP4) • Reference Leak Source (TIF XP-7) Additional Features XL-1A • Single switch control RX-1A • Six segment visual leak size indicator • True mechanical pump provides positive airflow through sensing tip • High and Low sensitivity levels • One touch reset • Tactile keypad controls XP-1A • Tri-color, Six segment visual leak size indicator displays 18 alarm levels • Seven levels of sensitivity adjustment provide an increase of up to 64x • Battery Test function with true voltage indication • Mute feature silences audible alarm • True mechanical pump provides positive airflow through sensing tip • One touch reset • Tactile keypad controls Specifications Power Supply Ultimate Sensitivity Sensing Tip Life Operating Temperature Battery life Duty Cycle Response Time Reset Time Warm up Time Dimensions Weight/Fixed Probe Length 96 3VDC; 2 "C" cell alkaline batteries XL-1A - Less than 11 gr/yr, RX-1A - Less than 7gr/yr, XP-1A - Less than 3 gr/yr Approximately 20 hours 0° to 50°C (32° to 122°F) RX-1A and XP-1A - Approx. 30 hours, XL-1A - Approx. 40 hours Continuous Instantaneous One second Approximately 2 seconds 22.9 cm x 5.7 cm x 5.7 cm 560 gr / 35.5 cm Combustible Gas Detectors TIF 8850 I TIF 8800 I TIF 8800A I Optional Accessories/Replacement Parts: • Custom carrying case (TIF548) • Cigarette lighter adapter (TIF8805) • 220 V battery charger (TIF8806B) • Sensing tip (TIF8801) • Rechargeable Ni-Cad batteries (TIF8806A) • Automatic warm up • Broad band detection • Low battery indicator • Recharger and ABS carrying case • Sensitivity Adjust control • Audible "Geiger counter" signal • LED Leak Intensity Lights (TIF 8800 I and TIF 8850 I only) • Autio Mute button to silence the alarm (TIF 8850 I only) • Applications: - Gas lines and pipes - Fuel in marine bilges - Exhaust and fuel leaks - Heat Exchanger leaks - Propane filling stations - Check manholes for safety - Liquid or gas fired heating systems, etc... Leak Detectors TIF 8800 I / TIF 8800A I / TIF 8850 I Partial List of Detectable Compounds Compound Min. detectable concentration Acetylene 50 ppm Iso-Butane (R600a) 500 ppm Methane 500 ppm Ethane (R170) 500 ppm Propane (R290) 500 ppm Ethylene 500 ppm Hydrogen 500 ppm Methyl Ether 500 ppm Vinyl Chloride 5 ppm Methyl Chloride 5 ppm Hydrogen Sulfide 5 ppm Acetone 50 ppm Methanol 50 ppm Ammonia (R717) 20 ppm Gasoline 1 ppm Chlorine 1 ppm Carbon Dioxide 500 ppm Specifications Operating Temperature Power Supply Battery Life Response Time Warm-up Time Probe/Cord length Dimensions Weight Ultimate Sensitivity 0° - 52°C (32° - 125°F) (2) 2.4V Ni-Cad Batteries 4 hours/charge Instantaneous 30 seconds 38 cm 20 x 7.6 x 5cm 434 grams 5-50 ppm 97 98 C-2001 • optical interface cable length color 1500 mm grey supported devices: Genius 5035/5080E, GSC-53A, Combitest, Speedtest, Isotest, Geotest MVK-02s length color C-2001 Accessories Interface Cable 1000 mm grey • RS-232 cable supported devices: Ultraplus Genius 5060, Ultraplus Genius 5080, EnergyTest 2020 E, Skylab, Ultraplus, Ultratest, Maxtest, Isotest Digi 5KV, DM-II RS-232 Cable 0701/2s MVK-02s length color 100 mm black • RS-232 cable for jack socket supported devices: Ultra 0701/0702S, Ultra 0751S Autotest RS-232 Cable RS-232 Cable 0701/2s length color 1000 mm black • RS-232 cable for Autotest and PC supported devices: Autotest 0701/0702S /751, PAT Tester 0701/2S /751 Autotest Adaptercable PDA Autotest RS-232 Cable length color 200 mm black • Autotest adapter cable for PDA supported devices: Autotest and PAT Tester, PDA Autotest Adaptercable PDA RS-Jack length color 1000 mm black • Interface-cable for Megatest-1 supported devices: Megatest-1 RS-Jack 99 Interface Cable USB to RS 232 Adapter length color 500 mm black • USB to RS 232 adapter supported devices: USB to RS 232 Apapter Sensing Line for Multimeter & Digital Clamp-Ons DTL-ABNC length color 1000 mm red/black • Sensing line with BNC-port supported devices: A 1000 DTL-1000 DTL-ABNC length color 1000 mm red or black • 2 sensing lines • ø 4 mm supported devices: A 1000 EU-200 DTL-1000 length color 1000 mm red or black • 2 alligator clips • 2 test prods • 2 sensing lines • ø 4 mm supported devices: AT 2000 Serie, AM-80er Serie MTL-90B EU-200 length color 1000 mm red or black • 2 sensing lines • 2 alligator clips • ø 2 mm supported devices: ACD-6 pro , ACD-10pro, ACDC- 400, AM-100er Serie PMTL-5 MTL-90B color red and black • test prod short • test prods long • alligator clip • sensing line supported devices: PMM-2 100 PMTL-5 ACF-5A CE • Adapter for digital Clamp-Ons length color 300 mm grey supported devices: Skylab, DM-II with ACF-3000, DM-A or ACF-3000SR ACF-6 ACF-5A CE length color Accessories Adaptercable for Digital Clamp-Ons 300/300 mm grey • Adapter for digital Clamp-Ons supported devices: Multimeter and ACF-3000AK ACF-6A ACF-6 length color 300 mm grey/red-black • Adapter for digital Clamp-Ons and measuring probes supported devices: DM-4, EnergyTest 2020 A, GSC 53 A, Genius 5080 E with digital Clamp-Ons and optional measuring probes ACF-6A Accessories for VDE 0100 Test Equipment COC2 color blue, black • 2 alligator clips supported devices: Isotest 2010 COC3 COC2 color blue, black, green • 3 alligator clips supported devices: Combitest 2019/Speedtest 2018 COC4 COC3 color blue, black, green, red • 4 alligator clips supported devices: Genius 5035/5080 E, GSC-53 A COC4 101 Accessories for VDE 0100 Test Equipment TPII-S • 1 test prod TPII-S TPII-R TPII-B black red blue supported devices: Genius 5035/5080 E, GSC-53, Combitest 2019, Isotest 2010 TLR-1F TPII-S length color 1200 mm red • safety sensing line 1000 V incl. fuse supported devices: Safetest, Alltest TLP2 TLR-1F length color 1000 mm blue, black • 2 sensing lines supported devices: Isotest 2010 TLP3 TLP2 length color 1500 mm blue, green, black • 3 sensing lines supported devices: Genius 5035/5080 E, GSC-53 A, Combitest 2019 TLP4-KitGE80 TLP3 length color 1000 mm red, green, blue, black • 4 sensing lines (red, green, blue, black) • 4 alligator clips (red, green, blue, black) • 2 test prods (blue, black) supported devices: GSC-53 A, Genius 5080 E SP3 TLP4-KitGE80 length color 1500 mm 3 conductors in green, blue, black • 3 conductors cable with three-pin plug supported devices: Genius 5035/5080 E, GSC-53 A, Combitest, Speedtest 102 SP3 TLE4 • 4 ground sensing lines supported devices: GSC-53 A/Geotest 2016/Genius 5035, Genius 5080 E MR4 20 m 15 m 5m blue red green or black TLE4 length color Accessories Accessories for VDE 0100 Test Equipment 300 mm messing • 4 ground stakes supported devices: GSC-53 A /Geotest/Genius 5035/Genius 5080 E MR4 Accessories for VDE 0701/0701 Test Equipment SP-3 ABL • Adapter for differential current or protection conductor current measurement with digital Clamp-On supported devices: PAT Tester 0701/0701 SZ, PAT Tester 0751 SZ SP-3 ABL DVA-16/DVA-32 • Adapter für differential current measurement with digital Clamp-On at 3 phase test items DVA-16 supported devices: PAT Tester 0701/0701 SZ, PAT Tester 0751 SZ DVA-32 TLP-0701 • Sensing line set for rotating field adapter coupler DAK-16, DAK-32 supported devices: ULTRA 0701/02S R-PE Cable 0701/2s TLP-0701 length color 100 mm black • Cable with alligator clip for resistor measurement supported devices: Ultra 0701/0702s, Ultra 0751S R-PE Cable 0701/2s 103 Bar code scanner for VDE 0701/0702 Test Equipment BC-Scanner for Autotest length color 200 mm grey • Bar code scanner for Autotest supported devices: Autotest 0701/0702s, PAT Tester 0701/2S BC-Scanner USB BC-Scanner for Autotest length color 200 mm grey • Bar code scanner with USB-port supported devices: Bar code scanner with connection to Laptop or PC BC-Scanner PS/2 BC-Scanner USB length color 200 mm grey • Bar code scanner with PS/2 port supported devices: Bar code scanner with connection to Laptop or PC BC-Pen for Autotest BC-Scanner PS/2 length color 100 mm grey • Bar code pen for Autotest or PAT Tester supported devices: Autotest 0701/0702s, PAT Tester 0701/2S 104 BC-Pen for Autotest PS/2 SV-U • Protective bag vinyl supported devices: AM-100er Series, AM-80er Series, ACD 10 Pro, ACD 14, ACDC 400 SV-U CC-ACDC Accessories Equipment-Protective Bag • Protective bag supported devices: ACD 320T, ACDC-3000, ACDC-620T, Amprobe Digital Ω, Amprobe Multitest CC-ACDC CN0050 • carrying strap supported devices: Genius 5035/5080 E, GSC-53 A, EnergyTest 2020 E CN0050 WP2000S • Protective bag 2000 supported devices: Combitest, Speedtest, Isotest, RCD-Test, Looptest, Geotest WP2000S WP2000 • Equipment - Protective Bag WP2000 supported devices: Combitest, Speedtest, Isotest, RCD-Test, Looptest, Geotest, Ultra 0701/2S WP2000 WP2050 • Equipment - Protective Bag supported devices: Genius 5035, Genius 5080 E, GSC-53 A, EnergyTest 2020 E WP2050 105 106 Type Test Leads DTL-1000 DTL-3000 DTL-ABNC MTL-90 B PMTL-5 EU-200 Holster+Cases CA 200 CC-AM-40 SV-U CC-ACDC CC 2000 Extensions A2201 B2024 ATGC-1 B2025 TMA-K DKTA-620 TAC-DMM TPK-56 TPK-59 Transducer for T-2200 Battery-Booster Advanced Tracer Groung Coil Battery Recharger for B2024 Temperature Adapter + Probe Dual K-Temperature Adapter Mono K-Temperature Adapter Flexible Temperature Probe 0,5 m Flexible Temperature Probe 0,5 m Instrument Case, small Standard Carrying Case Vinyl Standard Carrying Case Vinyl Carrying Case Instrument Case, large Test Leads Test Leads Test Leads (BNC) Test Leads Test Lead Set Standard Test Leads Description • • • • • • • ACD-30P ACD 10 Pro ACD ACD-31P 14 ACD-40PQ ACD-41PQ • • ACD 6 Pro • • • • ACDC ACD 400 15 Pro ACD 16 Pro • • • ACD 330 T • • • • • • ACDC 620 T • • • A 1000 • AM 42 45 47 • • • AM 220 240 • • • • AM 100 105 • • • AM 110 • • • • AM 120 140 Accessories + Replacement Parts for Multimeter, Clamp-Ons and Wire Tracers of AT 2000 Series • • • AM 130 150 160 • • • PMM2C • • • • • • • AT 2000 Series 107 Type Extensions TC-11 TC-12 TC-13 TC-14 Current Transducer A300 A400 A1000 CT-30 A97 Batteries MN-1604 (9V) S912 (AAA) CR2032 Fuses FA-6x32/.63 380.25-6x32 660.25-6x32 2502-6x32 FA-15 A/1000 V 5x20-250.5 6x32-250 V 10 A FA-12,5 A/500 V FA-1 A/1000 V Fuse 500 V/0,63 A Fuse 380 V/0,25 A fast acting Fuse 660 V/0,25 A fast acting Fuse 250 V/2 A fast acting Fuse 600 V/15 A Fuse 600 V/500 mA Fuse 600 V/10 A Fuse 600 V/12,5 A Fuse 1000 V/1 A 9 V Batteries 1,5 V Lady (AAA) 3 V Battery CR2032 Transducer 1 mA - 200 A AC Transducer 400 A AC Transducer 1000 A AC/DC Transducer 30 A AC/DC Transducer 1 mA - 1000 A Temperature Probe Temperature Probe Temperature Probe Temperature Probe Description • • • ACD-30P ACD 10 Pro ACD ACD-31P 14 ACD-40PQ ACD-41PQ • ACD 6 Pro • • ACDC ACD 400 15 Pro ACD 16 Pro • ACD 330 T • • ACDC 620 T • A 1000 • AM 42 45 47 • • • • AM 220 240 • • • • • • • • • • • • AM 100 105 110 • • • • • • • • • • • AM 120 130 • • • • • • • • • • • • AM 140 • • • • • • • • • • • • AM 150 160 • • • • AT 2000 Series Appendix • • • • • • • PMM2C 108 MR4 A-200 ACF-3003A A0050 C2001 WP2050 WP2000 WP1985 TLE4 COC4 TPII-S COC2 COC3 TLP4 Type SP3 TLP2 TLP3 Description 3 Wire Shuko Cabel 2 Test Leads, black, blue 3 Test Leads, black, blue, green Test Lead Set 4 Test Leads, black, blue, green, red 4 Alligator Clips 2 Test Tips black, blue 1 Tip, black 2 Alligator Clips, black, blue 3 Alligator Clips, black, blue, green 4 Alligator Clips, black, blue, green, red Ground Test Leads black 20 m, blue 15 m, green 5 m, red 5 m Earth Rods, 4 pcs. Mini-Clamp-on 200 A 3 flex. Current Tansducers 5 A- 3000 A External Power Supply Optoinsulated Cable Genius Protective Case Genius Protective Case 2000 Carrying Case Ground Cables • • • • • • • • • • • • GENIUS 80 E • GENIUS 5035 Overview Standard Accessories for VDE Test Instruments • • • • • • • • • • • • GSC-53 A • • • • SPEEDTEST 2018 • • • • • COMBITEST 2019 • • • • • INSULATION TESTER 2010 • • • GEOTEST 2016 109 TMA-K HT-53 CN 0050 WP 2000 S TP II R TP II B IMP-57 HT-52 CT-30 A-1000 A-97 DAA-16 DAA-32 A-300 Type A0050 HT24 Earth Cable Set Description External Power Supply Mini-Printer 4 Earth Rods, Set of Test Leads black 20 m, blue 15 m, green 5 m, red 5 m incl. Carrying Case Three Phace CEE Plug 16 A Three Phace CEE Plug 32 A Leakage Current Clamp-On 1 mA to 200 A AC Leakage Current Clamp-On 1 mA to 1000 A AC AC/DC Current Transducer AC/DC Current Transducer up to 1000 A AC and DC Temperature and Humidity Adapter Temperature Adapter Luxmeter Carrying Belt Carrying Case Tip red Tip blue Adapter for Impedance Measurement up tp 80 kA • • • • • • • • • • • • • • • • • • • • • • • GSC-53 A • • • • • • • • • GENIUS 80 E • • • • GENIUS 5035 Overview Optional Accessories VDE Test Instruments • • • • • • • COMBITEST 2019 • • • • SPEEDTEST 2018 • • • • • INSULATION TESTER 2010 • • GEOTEST 2016 Appendix Electrical and Other Terms Used in Test Instrumentation: AC - Abbreviation for Alternating Current dB - Decibels - Used in communication to indicte Volume. It is not a linear relationship, i.e. as dB increases the apparent volume increases more quickly. DC - Abbreviation for Direct Current G - Giga or 1 1000M. 3GQ is 3,000,000,000 ohms Hz - Hertz or frequency - Formerly called cycles as in 60 cycle. Frequency is expressed as the number of cycles per second, Usually 60 Hz in the U.S., 50 Hz in Europe. K - Thousands - applied to indicate thousands of volts or Amps. For example, 3KV means three thosand volts. KW - 1,000 watts - the common measure of Power. KWH - KiloWattHour - the measure of energy used. μ - Micro (one millionth or 1/1,000,000) m - Milli or one thousandth - as applied to voltage or amperage. For example, millivolts means thousandths of a volt. This is written as MV (or mA in the case of amperage) Harmonic Distortion - In the early 1980's, a new efficient power supply called a "switch mode power supply" began showing up in electronic products. This supply converts the incoming sine wave to a distorted waveform. If a device converts AC to DC or vice versa (via a switch mode power supply) as part of its routine operation, it is a harmonic generating device. Such devices include copiers, computers, UPS systems and many more common every day devices. Harmonics - Voltages or currents that are at a multiple of the fundamental frequency. In the US, the fundamental frequency is 60 Hz.; therefore, harmonics can occur at 120 Hz, 180 Hz, 240 Hz and so on. Harmonics are usually specified by their numeric order. For example, the third harmonic is 180 Hz (60x3). Hold - The ability of a digital instrument to retain (Hold) its Last Reading after connections to the circuit are removed. M - Million - for example, 3 MO is 3,000,000 ohms Impedance - The loading (impedance), in ohms, an instrument presents to the circuit being tested. (This is typically 10 meg ohms for digital multimeters). O - Ohms - The omega symbol is used to represent ohms, the unit of electrical resistance in a circuit. Peak - The absolute maximum (crest) excursion or a measured waveform from the zero reference. RS-232 - An EIA defined standard permitting serial communications between computer terminals, modems, instruments, etc. Polarity - The ability of a digital instrument to display polarity to determine the direction of current flow. V - Volts or Voltage Power Factor - Ratio of Actual Power to the Apparent Power Apparent Power - Apparent Power equals the calculated Watts as in: Volts x Amps = Watts. Apparent power is indicated in watts. Range - A measurement Span (i.e.: 0-200 is range of measurement) Auto Ranging - Instrument automatically selects best Range For Measurement being made. Sag (Valley) - A sudden DECREASE in the amplitude of the nominal electrical value. This disturbance lasts for 1/2 cycle (60 Hz) or longer. Capacitance - A capacitor is an electronic component that stores energy like a bettery. Capacitance is a measure of the capacitors storage capacity, usually stated in microfarads. Spike (Noise) - An abrupt transient of less than one millisecond which comprises parts of a waveform and may considerably exceed its average amplitude. Crest - Peak or top most part of a waveform from the zero reference Surge (Swell) - A sudden INCREASE in the amplitude of the nominal electrical value. This disturbance last for 1/2 cycle (60 Hz) or longer. Continuity - An electrical test to determine if a continuous path for the flow of current is established. Counts - The maximum number (counts) a digital instrument can display (1999 display is 2000 counts). Diode Test - Instrument can test the forward and reverse conduction conditions of a Diode. 110 Duty Cycle - The ratio of Time On vs. Time Off of a machine or waveform. True RMS - Indicates an instrument's ability to measure a waveform other than sinusoidal. A true RMS instrument will display the correct voltage or amperage despite a distorted waveform Vars (Q) - Volt amp reactive (Wasted Power) R-3000 and G-3000 Appendix Helpful Hints/AT-3000 Userguide The R-3000 and G-3000 combine to make the perfect general purpose tools for cable avoidance. Their rugged construction ensures long life and reliability whilst the simple controls promote effective use with minimal training. For those who require pinpoint accuracy and depth information, the AT-3000 add visual indication of signal strength together with a buried utility depth measurement capability. G-3000 R-3000 R-3000 Locator features G-3000 Transmitter features 1 On/Off Press and hold to use R-3000 1 On/Off button Press and hold to reduce speaker volume. 2 Loudspeaker To use in noisy environments unscrew and hold to ear. 2 Direct Connection socket 3 Loudspeaker 3 Sensitivity control 4 Battery compartment To replace batteries, open the access cover using a screwdriver or coin. Use 4 LR20 or D alkaline batteries 4 Function switch Selects locate mode: Power, Radio, G-3000 5 Battery compartment To replace batteries, open the access cover using a screwdriver or coin. Use eight LR6 or AA alkaline batteries Liquid crystal display 5 Storage compartment Holding Connection Cable and Ground Stake. Depth Mode/clockface Signal strength Depth button 111 Helpful Hints/AT-3000 Userguide Operation of Power and Radio modes WARNING Regularly check your R-3000 and G-3000 in all modes, over a cable which gives a response you are familiar with. The R-3000 will detect almost all buried conductors but there are some which do not radiate any signal which the R-3000 will not detect. Power mode For detection of 'Power' signals radiated by loaded cables. These are often found 're-radiated' by other, nearby conductors. Select Power using the Function switch. Press and hold the On/Off switch. Replace batteries if no initial 'bleep' is heard to confirm good battery condition. Rotate the Sensitivity Control fully clockwise for maximum sensitivity but reduce if there is a blanket signal across the site. Define the area to be excavated and carry out a grid pattern sweep beyond the perimeter of the area to be excavated. The presence of a buried conducting pipe or cable will be indicated by a tone emitted from the loudspeaker. Keep the blade of the R-3000 vertical and move slowly backwards and forwards over the conductor, reducing the sensitivity for a narrower response. With the R-3000 use the meter deflection to aid pinpointing. Maximum meter deflection will indicate the position of the conductor. The R-3000 does not indicate whether a signal is from a single cable or from several in close proximity. Note The R-3000 will not provide depth information in either the Power or Radio modes. Locating with the R-3000 and G-3000 The G-3000 is used to apply a tone to a buried conductor. This signal can be traced using the R-3000 locator switched to the G-3000 mode. Direct Connection Direct connection is the most effective form of signal application and is suitable for connection to a valve, meter, junction box or other access point. WARNING Connection to a power cable sheath should only be undertaken by qualified personnel. When directly over the conductor and with the sensitivity level set Method for a narrow response, rotate the R-3000 on its axis until the signal minimum is found. The blade is now in line with the conductor. Plug the Connection lead into the G-3000 connection socket and attach the red lead to the target line. If necessary clean the connection point to ensure a good electrical contact. Trace the conductor out of the area, marking the position as required with chalk or paint. Radio mode For detectioin of radio signals originating from distant radio transmitters. These penetrate the ground and are re-radiated by buried conductors. However, they are not always present. 112 There are also some live power cables which the R-3000 is not able to detect. Clip the ground lead to the earth stake which should be placed in the ground 3 to 4 paces away from, and at right angles to the target line. Alternatively the ground lead may be clipped the rim of a valve box or manhole cover. Use the spool lead to extend the earth connection if necessary. Switch the G-3000 on. A good connection is indicated by a drop in loudspeaker tone. If there is no tone or it is a very slow bleep, replace the batteries. Switch the G-3000 to G-3000 mode and begin to trace the line from the point of application. Pinpoint using the same method as described for Power and Radio modes. Induction Alternatively, use a two man technique to search an area for buried utilities. Taking line depth measurment using the R-3000 Depth measurement is only possible when using the R-3000 in the G-3000 mode. Method Locate the utility as described previously. Ensure that the depth measurement position is at least 30 paces from the G-3000, especially if signal application is by Induction method. Induction is a convenient and quick way of applying the G-3000 signal to a pipe or cable where limited access does not permit direct connection or use of the Signal Clamp. Hold the R-3000 still, vertical and at right angles to the buried line. Momentarily depress the depth button. The display will show a moving clock face followed by the depth measurement. Place the G-3000 over the assumed position of the conductor in the orientation shown. Depth measurment is only possible when using the R-3000 in the Start tracing the cable or pipe at least five paces from the G-3000 with the R-3000 in G-3000 mode. Working too close to the G-3000 may give false readings as the R-3000 will detect more signal directly from the G-3000 than from the conductor. Method Do not attempt to take depth readings unless the distance between the R-3000 and G-3000 is greater than 30 paces (see "Taking depth readings using the R-3000"). Appendix Helpful Hints/AT-3000 Userguide Taking Mouse depth measurements using the R-3000 G-3000 mode with a Mouse transmitter. Locate the main Mouse signal as previously described. Hold the R-3000 vertically and in line with the Mouse. Press and hold the depth button until 'M' appears on the display. A clock face will appear in the top right hand corner of the display while the depth calculation is made. The approximate depth to the Mouse will then be displayed on the meter. Active search using Induction Placing the G-3000 on its side swamps an area with G-3000 signal. 113 Helpful Hints/AT-3000 Userguide Optional Accessories Using the optional Signal Clamp SC-3000 Method The Signal Clamp applies a G-3000 signal safely to a pipe or live cable 76mm diameter, without interrupting the supply. Method Plug the Clamp into the G-3000 Connection socket. Place the Clamp around the pipe or cable ensuring the jaws are closed. Switch the G-3000 on. Open and close the Clamp. If the jaws are closing correctly a drop in speaker tone will be heard. An earth connection is not necessary but efficient signal transfer is only achieved if the target conductor is grounded at both ends. This is usually the case with power cables. Using the optional Mouse Signal Transmitter M-3000 The mouse is a small self-contained watertight transmitter which can be detected by the R-3000 when switched to the G-3000 mode. 114 Replace the battery in the Mouse. Attach the Mouse to a drain rod using an appropriate connector. Place the Mouse on the ground, set the R-3000 to G-3000 mode and, whilst holding the R-3000 in line with the Mouse, check that a signal is being received. Insert the Mouse approximately 1m/yd into the duct/drain and adjust the R-3000 sensitivity to receive the signal. A ghost signal appears before and behind the main signal position. Reduce the R-3000 sensitivity to receive the main signal. Product A PG Page 2502-6x32 380.25-6x32 5x20-250.5 6x32-250 V 10 A 660.25-6x32 B B A A B 107 107 107 107 107 A0050 A-97 A-200 A-300 A-400 A-1000 A-2201 ABA-1 ABA-1 FI ACD-6 Pro ACD-6 TRMS Pro ACD-10 Pro ACD-10 TRMS Pro ACD-14 ACD-14 TRMS ACD-15 Pro ACD-15 TRMS Pro ACD-16 Pro ACD-16 TRMS Pro ACD-30P ACD-31P ACD-40PQ ACD-41PQ ACD-51HP ACD-55HPQ ACD-56HPQ ACD-330 T ACDC-400 ACDC-620 T ACDC-3000 ACF-3000 AK ACF-3000 DM-A ACF-3000 SR ACF-3003 ACF-3003 A ACF-5A CE ACF-6 ACF-6A ALLTEST AM-42 AM-45 AM-47 AM-100 AM-105 TRMS AM-110 TRMS AM-120 TRMS AM-130 TRMS AM-140 TRMS AM-150 TRMS AM-160 TRMS AM-220 AM-240 AMB-25 AMB-35 APS 1012 AT-1000 AT-2001 AT-2002 AT-2003 AT-2004 AT-2005 AT-3000 B B B B A A B B B A A A A A A A A A A A A A A A A A A A A A B B B A A A A B B A A A A A A A A A A A A A B B B B B B B B B B 53 53 53 28+53 28 27 76 39 39 19 19 19 19 20 20 20 20 21 21 22 22 23 23 25 25 25 26 21 26 27 29 29 29 29 66 101 101 101 63 7 8 8 11 11 12 12 13 14 13 14 9 9 59 59 29 76 74 74 74 74 74 77 Product PG Page ATGC-1 Autotest 0701/2S Autotest 0701/2 plus 0751 Autotest Adapter Cable (PDA) Autotest CEE Adapter Autotest RS -232 Cable B B B B B B 75 40 41 99 41 99 B-2024 B-2025 B41 BC-Pen Autotest BC-Printer BC-Scanner Autotest BC-Scanner PS/2 BC-Scanner USB BC-Software label maker B B B B B B B B B 76 76 38 104 38 104 104 104 40 C-2001 CA-200 CC-2000 CC-ACDC CC-AM-40 CC-K-1 CC-TAM-100 CN0050 COC2 COC3 COC4 Combi Test 2019 CT-30 B B B A A A A B B B B B A 99 76 76 90+91 7+8 92 15 105 101 101 101 55 28 DAA-16 DAA-32 DAK-16 DAK-32 Democase VDE0100 DGC-1000 A Digital Ω DKTA-620 DLC-100 DMCT-CE DM-II DM-IV DPX-2000 DSA-3 DT-130 DT-136 DTL-1000 DTL-3000 DTL-ABNC DVA-16 DVA-32 B B B B B B A A A B B B A B A A A A A B B 53 53 38 38 30 58 91 85 30 68 72 70+71 85 39 83 83 100 106 100 103 103 e-manager Add-In e-manager Designer e-manager Pro ENERGYTEST 2020 E Earth cable set e-tester 0701/2 e-tester 0701/2 light EU-200 B B B B B B B B 35 35 34 68 53 44 44 100 F FA-1A/1000 V FA-6x32/.63 FA-12,5 A/500 V FA-15 A/1000 V A A A A 107 107 107 107 G GENIUS 5035 GENIUS 80 E B B 50 51 B C D E Product PG Page Geo Test 2016 GSC-53 A GSC-53 A without transducer B B B 57 66 66 HT-24 HT-52 HT-53 B B B 40 53 53 IMP-57 Iso-Digi-5 kV Insulation Tester 2010 Insulation Tester AMB-5 kV B B B B 53 61 56 60 K KEW-4200 KEW-8141 KWIK-I-E B B A 58 42 92 L L810/1/50 L810/1/75 L810/1/100 L810/1/PWR LC-3000 LEXXI T 810 LM-80 LSP-2 LT-100 LZ-1 B B B B B B A A A B 79 79 79 79 78 79 85 89 84 40 M M-3000 MEGATEST-1 MN-1604 (9V) MR4 MT-100 MT-1000L MTL-90B MTL-CAP Multitest MVK-02s B B A B A A A A A B 78 60 107 103 48 88 100 22 90 99 P PDA-Set PM-1 PM-1A PM-1U PMM-2 PMM-2C PMM-C PMTL-5 Powertest 0701/2 3P PRM-2 PRM-3 PAT Tester 0701/2 S PAT Tester 0701/2 D PAT Tester 0701/2 SZ PAT Tester 0751 plus PAT Tester 0751 plus D PAT Tester 0751 plus Z B B B B A A A A B B B B B B B B B 40 49 49 49 16 16 16 100 46 64 64 42 42 42 43 43 43 R-2000 RA 43240 RCA R-PE Cable 0701/2s RS-232 Cable 0701/2s RS-232 Kit 1 RS-Jack B A B B B A A 75 83 63 103 99 15 99 S-2300 S-2600 S912 (AAA) B B A 75 75 107 H I R S Product PG Page SAFETEST SC-3000 Software 0701/2S Software 0751S SP-3 SP-3 ABL Speed Test 2018 ST-20 SV-U B B B B B B B B A 62 78 38 39 102 103 56 84 15+105 T T-2200 T10 TAC-DMM TAM-100 TC-11 TC-12 TC-13 TC-14 TDR-400 Test Labels TH-2A THWD-2 TIF 8800I/8800AI/8850I TIF RX-1A/XL-1A/XP-1A TIF ZX-1E TL-10S TLE4 TLP2 TLP3 TLP4-KitGE80 TLP-701 TLR-1F TMA-K TMULD-300 TPII-B TPII-R TPII-S TPK-56 TPK-59 TP-Chip 20 TP-Chip 30 TP-Chip 30W TP-Cleardisc TP-Glastag TP-Logitag 120 TP-Pigring TP Handheld reader USB B A A A A A A A B B A A A A A A B B B B B B A A B B B A A B B B B B B B B 75 85 85 15 85 85 85 85 80 40 82 82 97 96 95 84 103 102 102 102 103 102 84 86 102 102 102 85 85 45 45 45 45 45 45 45 45 U ULD-300 ULTRA 0701/0702S ULTRA 0751 USB/RS-232 USB to RS 232 Adapter UT-300 A B B B B A 86 38 39 15 100 86 V VP-440 VP-600 VP-600B VP-600SB A A A A 88 88 88 88 W WEP-IIM WEP-5P W-GT 1 WP 1985 WP2000 WP2000S WP2050 B B A B B B B 36 37 89 108 105 105 105 Appendix all products, alphabetcally sorted – Index 115 Amprobe Europe GmbH Lürriper Straße 62 · D-41065 Mönchengladbach · Germany Telephone +49 (0) 21 61-59 90 6-0 · Telefax +49 (0) 21 61-59 90 6-16 www.amprobe.de · www.amprobe.co.uk · [email protected]