Thermostatic Expansion Valves
Transcription
Thermostatic Expansion Valves
April 2011 / BULLETIN 10-10 Thermostatic Expansion Valves With Selective Thermostatic Charges ⚠WARNING – USER RESPONSIBILITY Failure or improper selection or improper use of the products described herein or related items can cause death, personal injury and property damage. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. OFFER OF SALE The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” available at www.parker.com. BULLETIN 10-10 — Page 1 t THERMOSTATIC EXPANSION VALVES 10 Outstanding Features & Benefits of Sporlan Thermostatic Expansion Valves • SELECTIVE THERMOSTATIC CHARGES Designed to provide optimum performance for all applications — air conditioning and heat pump, medium and low temperature refrigeration. • THERMOSTATIC ELEMENT DESIGN Long lasting and field proven stainless steel diaphragm and welded element construction. • DIAPHRAGM DESIGN Large flat diaphragm permits precise valve control. • REPLACEABLE THERMOSTATIC ELEMENTS Field replaceable elements on all standard valves. • ACCESSIBLE INTERNAL PARTS Durable, leakproof body joint construction allows the valve to be disassembled, and the internal parts cleaned and inspected. The thermostatic expansion valve (TEV) controls the flow of liquid refrigerant entering the direct expansion (DX) evaporator by maintaining a constant superheat of the refrigerant vapor at the outlet of the evaporator. The TEV controls the difference between the actual temperature and the saturation temperature of the refrigerant corresponding to the suction pressure at the sensing bulb location; this is superheat. By controlling • PIN CARRIER DESIGN (CONVENTIONAL VALVES) Provides precise pin and port alignment, and tighter seating. • BALANCED PORT DESIGN Provides perfect pin and port alignment, and prevents changes in pressure drop across the valve from influencing valve operation. Provides excellent control on applications with widely varying operating conditions. • MATERIALS OF CONSTRUCTION Pin and port materials offer maximum protection against corrosion and erosion. • SILVER SOLDERED CONNECTIONS For leakproof, high strength connection-to-body joints. • ADJUSTABLE SUPERHEAT DESIGN All standard valves are externally adjustable. superheat, the TEV keeps most of the evaporator surface active, while preventing liquid refrigerant from returning to the compressor. The ability of the TEV to match refrigerant flow to the rate at which refrigerant can be vaporized in the evaporator makes the TEV the ideal expansion device for most air conditioning and refrigeration applications. TABLE OF CONTENTS Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 BQ, EBQ, & SBQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-21 Valve Nomenclature / Ordering Instructions . . . . . . . . . . . 3 G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Recommended Thermostatic Charges . . . . . . . . . . . . . . . . . . 3 EG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 TEV Capacity Ratings for Refrigerants: BF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 22, 134a, 401A, 402A, 404A, 407C, 408A, 409A, 410A, SBF & EBF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-26 422D, and 507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Capacity Tables for Refrigerants: EBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 22, 134a, 401A, 402A, 404A, 407C, 408A, 409A, 410A, O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-30 422D, and 507 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 TEV Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . 9-11 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Valve Specifications V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 RC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 ER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Materials and Details of Construction . . . . . . . . . . . . . . . . 35 F & EF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-16 OEM Type Thermostatic Expansion Valves . . . . . . . . . . . . 36 Q, EQ, & SQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-21 Terms of Sale with Warranty Limitations . . . . . . . . . . . . . 37 Refer to Bulletin 10-9 for a complete discussion on The Theory of Operation and Application of Thermostatic Expansion Valves. Refer to Bulletin 10-11 for a complete discussion on Installing and Servicing Thermostatic Expansion Valves. FOR USE ON REFRIGERATION and/or AIR CONDITIONING SYSTEMS ONLY Bulletin 10-10, April 2011 supersedes Bulletin 10-10, October 2009 and all prior publications. Page 2 — BULLETIN 10-10 t SELECTION PROCEDURE The following procedure should be used when selecting a Sporlan TEV: 1.Determine the liquid temperature of the refrigerant entering the valve. The TEV capacity tables on pages 4 to 8 are based on a liquid temperature of 100°F for R-22, R-134a, R-401A, R-402A, R-404A, R-407C, R-408A, R-409A, R-410A, and R-507. For other liquid temperatures, apply the correction factor given in the tables for each refrigerant. For example see Table B. 2.Determine pressure drop across valve. The pressure drop correction factors are based on standard liquid temperature and pressure drop. The standard pressure drop is dependent on the evaporator temperature. To determine the pressure drop, subtract the saturated pressure equivalent to evaporator temperature from the condensing pressure. The condensing pressure used in this calculation should be the minimum operating condensing pressure of the system. From this value, subtract all other pressure losses to obtain the net pressure drop across the valve. Use this value to determine the pressure drop correction factor. For example see Table C. Be sure to consider all of the following possible sources of pressure drop: 1.Friction losses through refrigeration lines including the evaporator and condenser. 2.Pressure drop across liquid line accessories such as a solenoid valve and filter-drier. 3. Static pressure loss (gain) due to the vertical lift (drop) of the liquid line. 4. Pressure drop across a refrigerant distributor if used. Refer to Bulletin 20-10 for information on refrigerant distributors. 3. Select valve from the capacity tables. Select a valve based on the design evaporating temperature. If possible the valve capacity should be equal or slightly exceed the design rating of the system. Be sure to apply the appropriate correction factors for liquid temperature and pressure drop. Once the desired valve capacity has been located, determine the nominal capacity of the valve from the tables’ second column. On multiple evaporator systems, select each valve on the basis of individual evaporator capacity. For example see Table A. 4. Determine if an external equalizer is required. The amount of pressure drop between the valve outlet and bulb location will determine if an external equalizer is required. Refer to Bulletin 10-9 for further information on this subject. 5.Select body type. Select the body type according to the style connections desired. For complete specifications on each TEV type including nominal ratings, refer to pages 9 to 11. 6. Select the Sporlan Selective Thermostatic Charge. Select the charge according to the design evaporating temperature from the Table on page 3. Refer to Bulletin 10-9 for a complete discussion of the available Sporlan Selective Thermostatic Charges. Selection Example – Refrigerant 22 Application: medium temperature refrigeration Design evaporator temperature . . . . . . . . . . . . . . . . . . . . . Design condenser temperature . . . . . . . . . . . . . . . . . . . . . Refrigerant liquid temperature . . . . . . . . . . . . . . . . . . . . . . Design system capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . Available pressure drop across TEV: Condensing pressure (psig) . . . . . . . . . . . . . . . . . . . . . . . 182 Evaporating pressure (psig) . . . . . . . . . . . . . . . . . . . . . . . . 43 139 Liquid line and accessories loss (psi) . . . . . . . . . . . . . . . – 4 Distributor and tubes loss (psi) Q . . . . . . . . . . . . . . . . . – 35 100 Refrigerant liquid correction factor . . . . . . . . . . . . . . . . . . 1.17 Pressure drop correction factor . . . . . . . . . . . . . . . . . . . . 0.89 Use the following formula to calculate TEV capacity: TEV Capacity = TEV rating x CF liquid temperature x CF pressure drop EGVE-1 has valve capacity of: 1.09 x 1.17 x 0.89 = 1.14 Tons at 20°F evaporating temperature, 100 psi pressure drop and 70° liquid temperature. Thermostatic charge (from table on page 3): VC W Selection: EGVE-1-C 3/8” x 1/2” x 1/4” ODF x 5’ QAn externally equalized valve must be used on evapo- rators employing a refrigerant distributor due to the pressure drop created by the distributor. In addition, an externally equalized valve should always be used with air conditioning thermostatic charges to reduce the possibility of thermostatic charge migration. WPlease note that the refrigerant charge designation in the thermostatic charge (“V” in this case) is dropped when it is incorporated into the valve model designation. PANSION VALVE THERMOSTATIC EX FRIGERANTS - TONS CAPACITIES for RE The valve capacity should equal or MMERC slightly exceed the tonnage rating HEAT PUMP and CO AIR CONDITIONING, of the system. (For complete R-22 REF RIGERA NT t VA LVE TY PE S F-E F-G -EG F-E F-G -EG F-E F-G -EG G-EG F-E F-G -EG F-E F-G -EG capacity tables, see pages 4 and 5.) 22 ED THE RMOS TAT IC REC OM ME ND NOMINA L VZ, VZP 40 VCP 100 , VG A VC, Y CA PACIT TEM PER ATU RE °F 1/5 1/3 1/2 3/4 1 1-1 /2 EVA PORATOR 0° 40° 20° 0.2 0 0.2 2 0.19 0.3 5 0.3 8 0.3 3 0.4 5 0.4 9 0.4 3 0.7 5 0.8 2 0.71 1.0 0 1.0 9 0.9 5 1.6 0 1.74 1.5 2 -10 ° 0.17 0.2 7 0.3 5 0.6 8 0.8 6 1.2 2 -20 ° 0.15 0.2 4 0.3 1 0.6 1 0.7 7 1.0 9 -40 ° 0.11 0.18 0.2 3 Design Evaporating 0.4 5 Temperature 0.5 7 0.8 1 Table A 20°F 95°F 70°F 1 ton Liquid Temperature LIQ UID TE MP ER AT UR E EN TE RING TE RE FR IGE RA NT V °F 0° 10° 20° 30° 40° 50° 60° 70° 80° CORR EC TION FACT OR , CF LIQ UID TE 22 MP ER AT UR E 1.5 6 1.51 1.4 5 1.4 0 1.3 4 1.2 9 407C 1.2 3 1.17 1.12 1.6 9 1.6 2 1.5 5 1.4 9 1.4 2 1.3 5 1.2 8 1.2 1 1.14 Table B TEV Pressure Drop EVA POR ATOR TEMPER ATU RE °F 40° 20° & 0° -10° & -20° -40 ° TEV (psi ) PRE SSU RE DROP ACROSS 200 100 125 150 175 75 50 30 CF PRE SSU RE DROP COR REC TION FAC TOR , 1.12 1.22 1.32 1.41 0.55 0.71 0.87 1.00 1.00 1.10 1.18 1.26 0.89 0.77 0.49 0.63 0.91 1.00 1.08 1.15 0.82 0.71 0.45 0.58 0.85 0.93 1.00 1.07 0.76 0.65 0.41 0.53 Table C BULLETIN 10-10 — Page 3 t SELECTION PROCEDURE 7.Valve Nomenclature / Ordering Instructions Combine the letters and numbers in the following manner to obtain the complete valve designation. Also include all connection sizes and the capillary tube length. EXAMPLE EG Body Type V E Sporlan Code – Refrigerant Element Label Color Code “E” specifies external equalizer. Omission of letter “E” indicates valve with internal equalizer. e.g. EGV-1-C F =R-12 Yellow E = R -13 Blue V = R -22 Green G = R -23 Blue M=R-124 Blue J = R -134a Blue X = R -401A Pink L = R -402A Sand S = R -404A Orange V =R -407AGreen N =R -407CLt. Brown S =R -408APurple F =R -409AYellow Z =R -410ARose V =R -422DGreen R =R -502 Purple W=R-503 Blue P =R -507 Teal W= R -508BBlue – 1 – Nominal Capacity in Tons 3/8” ODF SOLDER C Thermostatic Charge x 1/2” ODF SOLDER Inlet Connection Outlet Connection Size and Style Size and Style x 1/4” ODF SOLDER x 5’ External Equalizer Connection Capillary Tubing Length Size and Style Inches or Feet RECOMMENDED THERMOSTATIC CHARGES* SPORLAN SELECTIVE CHARGES ENGINEERED for PEAK PERFORMANCE for EACH SPECIFIC APPLICATION APPLICATION Air Conditioning Commercial Refrigeration 50°F to -10°F Low Temperature Refrigeration 0°F to -40°F Extreme Low Temperature Refrigeration -40°F to -100°F *APPLICATION FACTORS: REFRIGERANT 12, 409A FCP60 – – – – – FC – – – FZ FZP – – – – – – 22, 422D, 410A 407A – – VCP100 – – ZCP180 VGA – – – – ZGA – – VC – – – – – – – – – VZ – VZP40 – – – – – VX – – – 407C 502 507 – – – – – – – – – LC – – – – LZ LZP – 404A, 408A – – – – SCP115 – – – SC – – – – – SZ SZP – – NCP100 – NGA – – – NC – – – – – – – – – – – – – RCP115 – – – RC – – – – – RZ RZP – – – – – – – – – – PC – – – – PZ PZP – ACTUAL THERMOSTATIC CHARGES JCP60 VCP100 ZCP180 VGA SCP115 ZGA JC VC SC PC JZ JZP VZ VZP40 SZ SZP VX LX SX – RX PX SX 134a 401A 402A JCP60 – – – – – JC – – – – – – – – – – XCP60 – – – – – XC – – – – – – – – – – – – 1. The Type ZP charges have essentially the same characteristics as the Type Z charge with one exception: they produce a pressure limit Maximum Operating Pressure (MOP). ZP charges are not intended as replacements for Z charges. Each should be selected for its own unique purpose. All air conditioning and heat pump charges are intended for use with externally equalized valves. Type L liquid charges are also available for most commonly used refrigerants in most element sizes. The Type X charges are not to be used with “EBS” and “O” valves. If in doubt as to which charge to use, review the section on thermostatic charges in Bulletin 10-9 or contact Sporlan Division of Parker, Washington, Missouri with complete system data. For dual temperature applications, use the “C” charge. The “C” charge may be used on applications down to -30°F on R-22, R-404A and R-507. 2. 3. 4. 5. 6. 7. TEV CAPACITY RATINGS FOR REFRIGERANTS: 22, 134a, 401A, 402A, 404A, 407C, 408A, 409A, 410A, 422D, 507 TEV capacity ratings for R-22, R-134a, R-401A, R-402A, R-404A, R-407C, R-408A, R-409A, R-410A, R-422D, and R-507 are based on vapor free 100°F liquid refrigerant entering the expansion valve, a maximum opening superheat of 7°F, and a standard factory air test superheat setting. A discussion of the relationship between valve capacities and superheat settings can be found in Bulletin 10-9. Standard Number 750. TEVs are tested in accordance with ANSI/ASHRAE 17. The ratings for evaporator temperatures 40°F, 20°F, -10°F, -40°F in the capacity tables are in accordance with ANSI/ARI For TEV capacity ratings at operating conditions not shown in the following tables, contact Sporlan Division of Parker. TEV models featuring the mechanical pressure limit style thermostatic elements, i.e., the Types G(PL) and C(PL) TEVs, are now obsolete. Consult Bulletin 210-10-17 for additional information on this subject and replacement valves. Page 4 — BULLETIN 10-10 t 22, 422D, 407C THERMOSTATIC EXPANSION VALVE CAPACITIES for REFRIGERANTS - TONS OF REFRIGERATION AIR CONDITIONING, HEAT PUMP and COMMERCIAL REFRIGERATION APPLICATIONS REFRIGERANT 422DQ 407C RECOMMENDED THERMOSTATIC CHARGE NOMINAL VALVE TYPES CAPACITY VC, VCP100, VGA VZ, VZP40 VC, VCP100, VGA VZ, VZP40 NC, NCP100, NGA EVAPORATOR TEMPERATURE °F 40° 20° 0° -10° -20° -40° 40° 20° 0° -10° -20° -40° 40° 20° 0° F-EF-G-EG 1/5 0.20 0.22 0.19 0.17 0.15 0.11 0.14 0.15 0.13 0.11 0.10 0.07 0.18 0.20 0.17 F-EF-G-EG 1/3 0.35 0.38 0.33 0.27 0.24 0.18 0.25 0.26 0.22 0.18 0.16 0.11 0.32 0.35 0.30 F-EF-G-EG 1/2 0.45 0.49 0.43 0.35 0.31 0.23 0.36 0.34 0.29 0.23 0.20 0.15 0.41 0.44 0.38 G-EG 3/4 0.75 0.82 0.71 0.68 0.61 0.45 0.54 0.57 0.48 0.45 0.40 0.28 0.69 0.74 0.64 F-EF-G-EG 1 1.00 1.09 0.95 0.86 0.77 0.57 0.71 0.76 0.64 0.57 0.50 0.36 0.92 0.99 0.85 F-EF-G-EG 1-1/2 1.60 1.74 1.52 1.22 1.09 0.81 1.14 1.21 1.02 0.81 0.71 0.51 1.47 1.58 1.36 F&EF(Ext)-G&EG(Ext)-S 2 2.00 2.18 1.91 1.96 1.75 1.31 1.43 1.51 1.28 1.30 1.14 0.82 1.84 1.97 1.70 F&EF (Int)-G&EG(Int) 2-1/2 2.50 2.72 2.38 2.20 1.97 1.47 1.78 1.89 1.60 1.45 1.28 0.92 2.30 2.46 2.12 F&EF (Ext)-G&EG (Ext)-S 3 3.20 3.49 3.05 2.33 2.09 1.56 2.28 2.42 2.05 1.54 1.36 0.97 2.94 3.16 2.71 S 4 4.50 4.90 4.29 3.43 3.07 2.29 3.21 3.40 2.88 2.27 1.99 1.43 4.14 4.44 3.81 S 5 5.20 5.67 4.96 4.04 3.62 2.70 3.71 3.93 3.33 2.67 2.35 1.69 4.78 5.13 4.41 S(Ext) 8 8.00 8.72 7.04 5.82 4.87 3.59 5.70 6.04 4.73 3.85 3.16 2.24 7.35 7.89 6.25 S(Ext) 10 10.0 10.9 8.80 7.27 6.08 4.48 7.13 7.56 5.91 4.81 3.95 2.80 9.19 9.86 7.82 H 5-1/2 5.60 5.98 5.34 4.59 3.39 2.73 3.99 4.15 3.59 3.03 2.20 1.71 5.15 5.41 4.75 H 7 7.00 7.48 6.67 5.14 3.79 3.06 4.99 5.18 4.48 3.40 2.46 1.91 6.43 6.76 5.93 H 11 10.5 11.2 10.0 7.00 5.17 4.17 7.49 7.77 6.73 4.63 3.36 2.61 9.65 10.1 8.90 H 16 15.2 16.2 14.5 10.0 7.38 5.96 10.8 11.3 9.74 6.61 4.79 3.72 14.0 14.7 12.9 H 20 22.2 23.7 21.2 16.3 12.0 9.71 15.8 16.4 14.2 10.8 7.81 6.07 20.4 21.5 18.8 M 21 21.5 23.4 22.5 18.4 16.3 13.2 15.3 16.2 15.1 12.2 10.6 8.27 19.8 21.2 20.0 M 26 26.5 28.9 27.8 26.0 23.0 18.7 18.9 20.0 18.7 17.2 15.0 11.7 24.4 26.1 24.7 M 34 34.0 37.1 35.6 30.6 27.1 22.0 24.2 25.7 24.0 20.2 17.6 13.8 31.3 33.5 31.7 M 42 42.0 45.8 44.0 39.6 32.7 25.2 29.9 31.7 29.6 26.2 21.3 15.8 38.6 41.4 39.2 BALANCED PORT THERMOSTATIC EXPANSION VALVES AAA BF-EBF-SBF 0.35 0.38 0.33 0.27 0.24 0.18 0.25 0.26 0.22 0.18 0.16 0.11 0.32 0.34 0.30 BF-EBF-SBF AA 0.75 0.82 0.71 0.68 0.61 0.45 0.54 0.57 0.48 0.45 0.40 0.28 0.69 0.74 0.64 BF-EBF-SBF A 1.60 1.74 1.52 1.22 1.09 0.81 1.14 1.21 1.02 0.81 0.71 0.51 1.47 1.58 1.36 BF-EBF-SBF B 2.80 3.05 2.67 2.25 2.01 1.50 2.00 2.12 1.79 1.49 1.31 0.94 2.57 2.76 2.37 BF-EBF-SBF C 5.20 5.67 4.96 4.04 3.62 2.70 3.71 3.93 3.33 2.67 2.35 1.69 4.78 5.13 4.41 EBS 8 8.51 8.81 7.30 6.15 5.15 3.79 6.06 6.10 4.90 4.06 3.34 2.37 7.81 7.96 6.48 EBS 11 11.5 11.9 9.86 8.32 6.96 5.13 8.20 8.25 6.63 5.50 4.52 3.21 10.6 10.8 8.77 EBS 15 15.5 16.3 12.2 11.1 8.88 6.85 11.0 11.3 8.19 7.33 5.77 4.28 14.2 14.7 10.8 EBS 20 22.3 22.8 16.9 15.4 12.4 8.66 15.9 15.8 11.4 10.2 8.02 5.42 20.5 20.6 15.0 O 15 15.0 15.5 13.0 9.20 8.15 6.14 10.7 10.8 8.75 6.08 5.29 3.84 13.8 14.1 11.6 O 20 22.2 23.0 19.3 16.3 12.0 9.71 15.8 15.9 13.0 10.8 7.81 6.07 20.4 20.8 17.1 O 30 30.5 31.6 26.5 19.4 17.1 14.4 21.7 21.9 17.8 12.8 11.1 8.97 28.0 28.6 23.6 O 40 40.3 43.5 32.0 29.5 26.1 21.8 28.7 30.1 21.5 19.5 17.0 13.6 37.0 39.3 28.5 O 55 55.0 59.3 43.7 39.4 29.9 24.3 39.2 41.1 29.4 26.0 19.4 15.2 50.6 53.7 38.9 O 70 73.0 78.8 58.0 51.5 34.0 26.4 52.0 54.6 39.0 34.0 22.1 16.5 67.1 71.3 51.6 V 52 52.0 56.1 54.0 52.2 37.0 29.5 37.1 38.9 36.3 34.5 24.0 18.4 47.8 50.8 48.0 V 70 73.0 78.8 75.8 71.6 50.7 40.4 52.0 54.6 50.9 47.3 32.9 25.3 67.1 71.3 67.4 V 100 100 108 104 92.2 65.3 52.1 71.3 74.8 69.8 60.9 42.4 32.6 91.9 97.6 92.3 W 135 143 154 148 132 93.5 74.5 102 107 99.7 87.3 60.7 46.6 131 140 132 W 180 180 – – – – – 128 – – – – – 165 – – VALVE TYPES CARTRIDGE NO. REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES Q-EQ-SQ 0 1/3 0.35 0.38 0.33 0.27 0.24 0.18 0.25 0.26 0.22 0.18 0.16 0.11 0.32 0.35 0.30 Q-EQ-SQ 1 3/4 0.75 0.82 0.72 0.68 0.61 0.45 0.54 0.57 0.48 0.45 0.40 0.28 0.69 0.74 0.64 Q-EQ-SQ 2 1 1.00 1.09 0.95 0.86 0.77 0.57 0.71 0.76 0.64 0.57 0.50 0.36 0.92 0.99 0.85 Q-EQ-SQ 3 1-1/2 1.50 1.64 1.43 1.10 0.99 0.73 1.07 1.13 0.96 0.73 0.64 0.46 1.38 1.48 1.27 Q-EQ-SQ 4 2-1/2 2.50 2.73 2.38 2.20 1.97 1.47 1.78 1.89 1.60 1.45 1.28 0.92 2.30 2.46 2.12 Q-EQ-SQ 5 3-1/2 3.50 3.82 3.34 3.00 2.69 2.00 2.50 2.64 2.24 1.98 1.74 1.25 3.22 3.45 2.97 Q-EQ-SQ 6 5 4.80 5.24 4.58 3.65 3.27 2.44 3.42 3.63 3.07 2.41 2.12 1.52 4.41 4.73 4.07 Balanced port replaceable cartridges, AAA, AA, A, B and C, have the same capacities as the matching nominal capacity of the BQ-EBQ-SBQ standard balanced port valves above. 22 REFRIGERANT 0° 10° 22 422D 407C 1.56 1.99 1.69 1.51 1.90 1.62 LIQUID TEMPERATURE ENTERING TEV °F 30° 40° 50° 60° 70° 80° 90° 100° 110° CORRECTION FACTOR, CF LIQUID TEMPERATURE 1.45 1.40 1.34 1.29 1.23 1.17 1.12 1.06 1.00 0.94 1.80 1.70 1.60 1.50 1.41 1.31 1.20 1.10 1.00 0.90 1.55 1.49 1.42 1.35 1.28 1.21 1.14 1.07 1.00 0.93 30 50 0.55 0.49 0.45 0.41 0.71 0.63 0.58 0.53 EVAPORATOR TEMPERATURE °F 40° 20° & 0° -10° & -20° -40° 20° 120° 130° 140° 0.88 0.82 0.76 0.79 0.68 0.57 0.85 0.77 0.69 PRESSURE DROP ACROSS TEV (psi) 75 100 125 150 175 200 225 250 275 300 CORRECTION FACTOR, CF PRESSURE DROP 0.87 1.00 1.12 1.22 1.32 1.41 1.50 1.58 1.66 1.73 0.77 0.89 1.00 1.10 1.18 1.26 1.34 1.41 1.48 1.55 0.71 0.82 0.91 1.00 1.08 1.15 1.22 1.29 1.35 1.41 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.20 1.25 1.31 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from -40°F to 40°F since the variation in the actual factors across this range is insignificant. TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 2 ton R-22 Type S valve at 20°F evaporator, 100 psi pressure drop across the TEV, and 90°F liquid temperature entering the TEV = 2.18 (from rating chart) x 1.06 (CF liquid temperature) x 0.89 (CF pressure drop) = 2.06 tons. Q R-422D can be used in a system with R-22 valves, but the TEV capacity will be reduced. Please verify valve capacity will handle system load. BULLETIN 10-10 — Page 5 t 22, 422D, 407C THERMOSTATIC EXPANSION VALVE CAPACITIES for REFRIGERANTS - TONS OF REFRIGERATION AIR CONDITIONING and HEAT PUMP APPLICATIONS VALVE TYPES NOMINAL CAPACITY ER, RC ER, RC ER, RC ER, RC ER, RC ER, RC ER, RC ER ER ER 1 1-1/2 2 3 4 5 6 8 10 12 REFRIGERANT 0° 10° 22 422D 407C 1.56 1.99 1.69 1.51 1.90 1.62 EVAPORATOR TEMPERATURE °F 40° 20° & 0° 22 40° 1.0 1.8 2.3 3.2 4.2 5.0 6.0 8.0 10.4 12.1 20° 1.1 1.9 2.5 3.5 4.6 5.5 6.5 8.7 11.4 13.2 REFRIGERANT 422DQ RECOMMENDED THERMOSTATIC CHARGE VCP100, VGAW EVAPORATOR TEMPERATURE °F 0° 40° 20° 0° 40° 1.0 0.71 0.76 0.66 0.9 1.7 1.25 1.32 1.15 1.6 2.2 1.64 1.74 1.51 2.1 3.1 2.28 2.42 2.10 2.9 4.1 2.99 3.17 2.75 3.9 4.9 3.56 3.78 3.27 4.6 5.3 4.28 4.53 3.54 5.5 7.8 5.70 6.04 5.24 7.4 10.2 7.44 7.88 6.83 9.6 11.8 8.62 9.14 7.92 11.1 LIQUID TEMPERATURE ENTERING TEV °F 30° 40° 50° 60° 70° 80° 90° 100° 110° CORRECTION FACTOR, CF LIQUID TEMPERATURE 1.45 1.40 1.34 1.29 1.23 1.17 1.12 1.06 1.00 0.94 1.80 1.70 1.60 1.50 1.41 1.31 1.20 1.10 1.00 0.90 1.55 1.49 1.42 1.35 1.28 1.21 1.14 1.07 1.00 0.93 20° 50 20° 1.0 1.7 2.3 3.2 4.1 4.9 5.9 7.9 10.3 11.9 0° 0.9 1.5 2.0 2.8 3.6 4.3 4.7 6.9 9.0 10.5 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of 0°F. However, they may be 0.88 0.82 0.76 used for any evaporator temperature from -40°F to 40°F 0.79 0.68 0.57 since the variation in the actual factors across this range 0.85 0.77 0.69 is insignificant. 120° 130° 140° PRESSURE DROP ACROSS TEV (psi) 75 100 125 150 175 200 225 250 275 300 CORRECTION FACTOR, CF PRESSURE DROP 0.55 0.71 0.87 1.00 1.12 1.22 1.32 1.41 1.50 1.58 1.66 1.73 0.49 0.63 0.77 0.89 1.00 1.10 1.18 1.26 1.34 1.41 1.48 1.55 30 407C TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 2 ton R-22 Type S valve at 20°F evaporator, 100 psi pressure drop across the TEV, and 90°F liquid temperature entering the TEV = 2.18 (from rating chart) x 1.06 (CF liquid temperature) x 0.89 (CF pressure drop) = 2.06 tons. Q R-422D can be used in a system with R-22 valves, but the TEV capacity will be reduced. Please verify valve capacity will handle system load. W The RC valve for R-22 applications is only available with a VGA element. t 410A THERMOSTATIC EXPANSION VALVE CAPACITIES for REFRIGERANTS - TONS OF REFRIGERATION AIR CONDITIONING and HEAT PUMP APPLICATIONS VALVE TYPES ER, RC ER, RC ER, RC ER, RC ER, RC ER, RC ER, RC ER ER ER REFRIGERANT 410A RECOMMENDED NOMINAL THERMOSTATIC CHARGE CAPACITY ZCP180, ZGAQ EVAPORATOR TEMPERATURE °F 40° 20° 0° 1 1.2 1.3 1.2 1-1/2 2.1 2.3 2.0 2 2.7 3.0 2.7 3 3.8 4.1 3.7 4 5.0 5.4 4.9 5 5.9 6.5 5.8 6 7.1 7.8 6.3 8 9.5 10.4 9.3 12-1/2 12.3 13.5 12.1 15 14.3 15.7 14.0 LIQUID TEMPERATURE ENTERING TEV °F REFRIGERANT 40 50 60 70 80 90 100 110 120 130 140 CORRECTION FACTOR, CF LIQUID TEMPERATURE 410A 1.39 1.31 1.23 1.17 1.12 1.06 1.00 0.94 0.88 0.82 0.76 Q The RC valve for R-410A applications is only available with a ZGA element. VALVE TYPES OZE-20 OZE-25 OZE-35 OZE-50 OZE-60 CARTRIDGE VALVE TYPES TYPE BQ, EBQ, SBQ AAA BQ, EBQ, SBQ AA BQ, EBQ, SBQ A BQ, EBQ, SBQ B BQ, EBQ, SBQ C EVAPORATOR TEMPERATURE °F 40° 20° & 0° REFRIGERANT 410A RECOMMENDED NOMINAL THERMOSTATIC CHARGE CAPACITY ZCP180, ZGA EVAPORATOR TEMPERATURE °F 40° 20° 0° 20 19.7 21.6 20.4 25 23.7 25.9 24.5 35 32.6 35.6 33.6 50 49.3 54.0 51.0 60 59.2 64.8 61.2 1/3 3/4 1-3/4 3-1/2 6 0.4 0.9 1.9 3.4 6.2 0.5 1.0 2.1 3.7 6.8 0.4 0.9 1.8 3.2 5.9 PRESSURE DROP ACROSS TEV (psi) 120 160 200 240 280 320 360 CORRECTION FACTOR, CF PRESSURE DROP 0.71 0.87 1.00 1.12 1.22 1.32 1.41 1.50 0.63 0.77 0.89 1.00 1.10 1.18 1.26 1.34 80 Page 6 — BULLETIN 10-10 t 404A, 408A THERMOSTATIC EXPANSION VALVE CAPACITIES for REFRIGERANTS - TONS OF REFRIGERATION COMMERCIAL and LOW TEMPERATURE REFRIGERATION APPLICATIONS 404A REFRIGERANT 408A RECOMMENDED THERMOSTATIC CHARGE VALVE TYPES SC, SCP115 SZ, SZP SC, SCP115 SZ, SZP EVAPORATOR TEMPERATURE °F 40° 20° 0° -10° -20° -40° 40° 20° 0° -10° -20° F-EF-G-EG 1/8 0.15 0.16 0.15 0.15 0.13 0.11 0.20 0.21 0.20 0.22 0.19 F-EF-G-EG 1/6 0.23 0.24 0.23 0.24 0.21 0.17 0.31 0.33 0.32 0.34 0.30 F-EF-G-EG 1/4 0.29 0.31 0.29 0.31 0.27 0.22 0.39 0.42 0.41 0.43 0.38 F-EF-G-EG 1/2 0.56 0.59 0.56 0.59 0.51 0.42 0.75 0.81 0.77 0.83 0.72 F-EF-G-EG 1 1.02 1.10 1.04 1.10 0.94 0.79 1.37 1.50 1.44 1.54 1.34 F-EF-G-EG 1-1/2 1.53 1.61 1.39 1.47 1.26 1.05 2.05 2.19 1.92 2.06 1.79 F&EF(Ext)-G&EG(Ext)-S 2 2.04 2.14 1.84 1.96 1.68 1.40 2.74 2.92 2.54 2.74 2.38 S 3 2.86 3.00 2.52 2.45 2.10 1.75 3.83 4.08 3.48 3.43 2.98 S 4 4.08 4.28 3.60 3.42 2.94 2.45 5.48 5.83 4.97 4.80 4.17 S (Ext) 6 5.61 5.12 4.27 4.52 3.84 2.97 7.53 6.97 5.90 6.34 5.45 S (Ext) 7 7.14 6.51 5.44 5.76 4.90 3.79 9.58 8.87 7.50 8.08 6.94 H 3 2.85 2.72 2.32 2.45 2.08 1.65 3.83 3.71 3.20 3.434 2.95 H 4 4.08 3.89 3.15 3.42 2.91 2.32 5.48 5.30 4.34 4.80 4.13 H 6-1/2 6.63 6.33 5.12 5.32 4.52 3.60 8.90 8.61 7.06 7.46 6.41 H 9 9.69 9.25 7.48 6.11 5.19 4.13 13.0 12.6 10.3 8.57 7.36 H 12 13.3 12.7 10.2 9.79 8.31 6.62 17.8 17.2 14.1 13.7 11.8 M 15 16.1 17.1 13.1 13.8 12.4 10.0 21.6 23.3 18.0 19.3 17.5 M 20 21.0 22.3 16.4 17.3 15.5 12.5 28.2 30.3 22.7 24.2 22.0 M 25 26.2 27.8 20.5 20.3 18.2 14.7 35.2 37.8 28.3 28.4 25.8 M 30 31.6 33.5 24.7 23.5 21.1 17.0 42.4 45.7 34.1 32.9 29.9 BALANCED PORT THERMOSTATIC EXPANSION VALVES BF-EBF-SBF AAA 0.23 0.24 0.23 0.24 0.21 0.17 0.31 0.33 0.32 0.34 0.30 BF-EBF-SBF AA 0.46 0.49 0.46 0.45 0.39 0.32 0.62 0.66 0.64 0.63 0.55 BF-EBF-SBF A 1.02 1.10 1.04 1.10 0.94 0.79 1.37 1.50 1.44 1.54 1.34 BF-EBF-SBF B 1.89 1.98 1.66 1.60 1.37 1.14 2.53 2.70 2.30 2.24 1.95 BF-EBF-SBF C 2.86 3.00 2.50 2.45 2.10 1.75 3.83 4.08 3.48 3.43 2.98 EBS 6 5.71 5.63 4.61 4.15 3.28 2.97 7.67 7.66 6.40 5.82 4.66 7.41 5.93 EBS 7-1/2 7.75 7.64 6.26 5.28 4.18 3.78 10.4 10.4 8.68 EBS 10 9.54 9.63 7.25 6.72 5.56 4.64 12.8 13.2 10.0 9.42 7.88 EBS 13 13.6 14.0 10.2 9.54 8.00 6.15 18.3 19.0 14.2 13.4 11.4 O 9 9.69 9.24 7.24 6.11 5.31 4.43 13.0 12.6 10.1 8.57 7.53 O 12 13.3 12.6 9.91 9.74 8.46 7.06 17.8 17.2 13.8 13.6 12.0 O 21 21.4 20.4 14.3 11.7 10.1 8.46 28.8 27.8 19.8 16.4 14.4 O 30 30.8 32.3 23.0 17.5 15.2 12.7 41.4 44.0 32.0 24.5 21.5 O 35 35.7 37.4 26.7 19.0 16.5 13.8 47.9 51.0 37.0 26.6 23.4 O 45 45.9 48.1 34.3 21.9 19.0 15.9 61.6 65.6 47.6 30.7 26.9 V 38 38.7 39.4 33.6 33.2 30.5 24.1 52.0 53.7 46.6 46.6 43.2 V 50 52.0 52.9 45.1 47.4 43.5 34.4 69.8 72.1 62.6 66.5 61.7 V 70 71.4 72.6 62.7 66.4 60.9 48.1 95.8 99.0 87.0 93.1 86.4 VALVE TYPES CARTRIDGE NO. REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES Q-EQ-SQ 0 1/6 0.20 0.22 0.20 0.20 0.17 0.14 0.27 0.30 0.28 0.28 0.24 Q-EQ-SQ 1 1/4 0.46 0.49 0.46 0.45 0.39 0.32 0.62 0.66 0.64 0.63 0.55 Q-EQ-SQ 2 1/2 0.66 0.72 0.67 0.59 0.51 0.42 0.89 0.98 0.94 0.83 0.72 Q-EQ-SQ 3 1 1.02 1.07 0.89 0.85 0.73 0.61 1.37 1.46 1.24 1.19 1.03 Q-EQ-SQ 4 1-1/2 1.63 1.71 1.44 1.47 1.26 1.05 2.19 2.33 1.99 2.06 1.79 Q-EQ-SQ 5 2 2.14 2.25 1.88 1.96 1.68 1.40 2.88 3.06 2.61 2.74 2.38 Q-EQ-SQ 6 3 2.86 3.00 2.51 2.45 2.11 1.75 3.83 4.08 3.48 3.43 2.98 Balanced port replaceable cartridges, AAA, AA, A, B and C, have the same capacities as the matching nominal capacity of the BQ-EBQ-SBQ standard balanced port valves above. NOMINAL CAPACITY REFRIGERANT 404A 408A LIQUID TEMPERATURE ENTERING TEV °F 30° 40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140° CORRECTION FACTOR, CF LIQUID TEMPERATURE 2.04 1.94 1.84 1.74 1.64 1.54 1.43 1.33 1.22 1.11 1.00 0.89 0.77 0.65 0.53 1.66 1.60 1.54 1.47 1.40 1.34 1.27 1.21 1.14 1.07 1.00 0.93 0.86 0.79 0.71 EVAPORATOR TEMPERATURE °F 40° 20° & 0° -10° & -20° -40° 0° 10° 30 0.55 0.49 0.45 0.41 20° PRESSURE DROP ACROSS TEV (psi) 75 100 125 150 175 200 225 250 CORRECTION FACTOR, CF PRESSURE DROP 0.71 0.87 1.00 1.12 1.22 1.32 1.41 1.50 1.58 0.63 0.77 0.89 1.00 1.10 1.18 1.26 1.34 1.41 0.58 0.71 0.82 0.91 1.00 1.08 1.15 1.22 1.29 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.20 50 -40° 0.16 0.25 0.32 0.61 1.14 1.53 2.04 2.54 3.56 4.32 5.51 2.41 3.37 5.24 6.01 9.60 14.5 18.2 21.4 24.7 0.25 0.47 1.14 1.66 2.54 4.32 5.49 6.74 8.94 6.44 10.3 12.3 18.4 20.0 23.1 35.1 50.0 70.0 0.21 0.47 0.61 0.88 1.53 2.04 2.54 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from -40°F to 40°F since the variation in the actual factors across this range is insignificant. 275 1.66 1.48 1.35 1.25 TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 1-1/2 ton R-404A Type EG valve at -20°F evaporator, 125 psi pressure drop across the TEV, and 60°F liquid temperature entering the TEV = 1.26 (from rating chart) x 1.43 (CF liquid temperature) x 0.91 (CF pressure drop) = 1.64 tons. BULLETIN 10-10 — Page 7 t 402A, 507 THERMOSTATIC EXPANSION VALVE CAPACITIES for REFRIGERANTS - TONS OF REFRIGERATION COMMERCIAL and LOW TEMPERATURE REFRIGERATION APPLICATIONS 402A REFRIGERANT 507 RECOMMENDED THERMOSTATIC CHARGE VALVE TYPES LC LZ, LZP PC PZ, PZP EVAPORATOR TEMPERATURE °F 40° 20° 0° -10° -20° -40° 40° 20° 0° -10° -20° F-EF-G-EG 1/8 0.15 0.16 0.15 0.16 0.13 0.11 0.14 0.15 0.14 0.15 0.13 F-EF-G-EG 1/6 0.23 0.24 0.23 0.24 0.21 0.18 0.22 0.24 0.22 0.24 0.20 F-EF-G-EG 1/4 0.29 0.31 0.29 0.31 0.27 0.23 0.29 0.30 0.29 0.30 0.26 F-EF-G-EG 1/2 0.56 0.59 0.56 0.59 0.51 0.43 0.55 0.58 0.54 0.58 0.50 F-EF-G-EG 1 1.02 1.10 1.04 1.11 0.95 0.80 1.00 1.08 1.01 1.08 0.93 F-EF-G-EG 1-1/2 1.52 1.61 1.39 1.48 1.27 1.07 1.50 1.57 1.36 1.44 1.24 F&EF(Ext)-G&EG(Ext)-S 2 2.03 2.14 1.84 1.97 1.70 1.42 2.00 2.09 1.79 1.92 1.65 S 3 2.85 3.00 2.52 2.47 2.12 1.78 2.79 2.93 2.45 2.40 2.06 S 4 4.07 4.28 3.60 3.45 2.97 2.49 3.99 4.19 3.50 3.36 2.89 S (Ext) 6 5.59 5.12 4.27 4.56 3.88 3.02 5.49 5.00 4.16 4.43 3.77 S (Ext) 7 7.12 6.51 5.44 5.81 4.95 3.85 6.99 6.36 5.30 5.65 4.80 H 3 2.85 2.72 2.32 2.46 2.10 1.68 2.79 2.66 2.26 2.40 2.04 H 4 4.07 3.89 3.15 3.45 2.94 2.36 3.99 3.81 3.07 3.36 2.86 H 6-1/2 6.61 6.33 5.12 5.36 4.57 3.66 6.49 6.18 4.98 5.22 4.44 H 9 9.66 9.25 7.48 6.16 5.25 4.20 9.48 9.04 7.28 5.99 5.09 H 12 13.2 12.7 10.2 9.86 8.40 6.73 13.0 12.4 10.0 9.59 8.16 M 15 16.1 17.1 13.1 13.9 12.5 10.2 15.8 16.7 12.7 13.5 12.1 M 20 20.9 22.3 16.4 17.4 15.7 12.7 20.6 21.8 16.0 16.9 15.2 M 25 26.1 27.8 20.5 20.4 18.4 14.9 25.6 27.2 20.0 19.9 17.9 M 30 31.5 33.5 24.7 23.6 21.3 17.3 30.9 32.8 24.1 23.0 20.7 BALANCED PORT THERMOSTATIC EXPANSION VALVES BF-EBF-SBF AAA 0.23 0.24 0.23 0.24 0.21 0.18 0.23 0.24 0.22 0.24 0.21 BF-EBF-SBF AA 0.46 0.49 0.46 0.45 0.39 0.33 0.45 0.48 0.45 0.44 0.38 BF-EBF-SBF A 1.02 1.10 1.04 1.11 0.95 0.80 1.00 1.08 1.01 1.08 0.93 BF-EBF-SBF B 1.88 1.98 1.66 1.61 1.39 1.16 1.85 1.94 1.62 1.57 1.35 BF-EBF-SBF C 2.85 3.00 2.52 2.47 2.12 1.78 2.79 2.93 2.45 2.40 2.06 EBS 6 5.69 5.63 4.63 4.18 3.32 3.01 5.59 5.50 4.52 4.06 3.22 5.18 4.10 EBS 7-1/2 7.73 7.64 6.29 5.32 4.23 3.84 7.59 7.47 6.13 EBS 10 9.51 9.64 7.28 6.77 5.62 4.71 9.35 9.43 7.10 6.59 5.46 EBS 13 13.6 14.0 10.2 9.61 8.08 6.25 13.4 13.7 9.99 9.36 7.85 O 9 9.66 9.25 7.28 6.16 5.37 4.50 9.48 9.04 7.09 5.99 5.21 O 12 13.2 12.7 9.96 9.81 8.55 7.17 13.0 12.4 9.71 9.54 8.30 O 21 21.3 20.4 14.4 11.8 10.2 8.60 21.0 20.0 14.0 11.4 9.95 O 30 30.7 32.3 23.1 17.6 15.3 12.9 30.1 31.6 22.5 17.1 14.9 O 35 35.6 37.5 26.8 19.1 16.7 14.0 34.9 36.6 26.1 18.6 16.2 O 45 45.7 48.2 34.5 22.0 19.2 16.1 44.9 47.1 33.6 21.4 18.6 V 38 38.6 39.5 33.8 33.5 30.8 24.5 37.9 38.6 32.9 32.6 29.9 V 50 51.8 52.9 45.3 47.8 44.0 34.9 50.9 51.8 44.2 46.5 42.7 V 70 71.2 72.7 63.0 66.9 61.5 48.9 69.9 71.0 61.4 65.1 59.8 VALVE TYPES CARTRIDGE NO. REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES Q-EQ-SQ 0 1/6 0.20 0.22 0.20 0.20 0.17 0.15 0.20 0.21 0.20 0.20 0.17 Q-EQ-SQ 1 1/4 0.46 0.49 0.46 0.45 0.39 0.33 0.45 0.48 0.45 0.44 0.38 Q-EQ-SQ 2 1/2 0.66 0.72 0.67 0.59 0.51 0.43 0.65 0.70 0.66 0.58 0.50 Q-EQ-SQ 3 1 1.02 1.07 0.89 0.86 0.74 0.62 1.00 1.05 0.88 0.83 0.72 Q-EQ-SQ 4 1-1/2 1.63 1.71 1.44 1.48 1.27 1.07 1.60 1.67 1.41 1.44 1.24 Q-EQ-SQ 5 2 2.14 2.25 1.88 1.97 1.70 1.43 2.10 2.20 1.84 1.92 1.65 Q-EQ-SQ 6 3 2.86 3.00 2.51 2.47 2.13 1.77 2.79 2.93 2.46 2.40 2.07 Balanced port replaceable cartridges, AAA, AA, A, B and C, have the same capacities as the matching nominal capacity of the BQ-EBQ-SBQ standard balanced port valves above. NOMINAL CAPACITY REFRIGERANT 402A 507 LIQUID TEMPERATURE ENTERING TEV °F 30° 40° 50° 60° 70° 80° 90° 100° 110° 120° 130° 140° CORRECTION FACTOR, CF LIQUID TEMPERATURE 2.01 1.91 1.82 1.72 1.62 1.52 1.42 1.32 1.22 1.11 1.00 0.89 0.77 0.65 0.53 1.99 1.89 1.79 1.69 1.59 1.50 1.40 1.30 1.20 1.10 1.00 0.89 0.78 0.66 0.51 EVAPORATOR TEMPERATURE °F 40° 20° & 0° -10° & -20° -40° 0° 10° 30 0.55 0.49 0.45 0.41 20° PRESSURE DROP ACROSS TEV (psi) 75 100 125 150 175 200 225 250 CORRECTION FACTOR, CF PRESSURE DROP 0.71 0.87 1.00 1.12 1.22 1.32 1.41 1.50 1.58 0.63 0.77 0.89 1.00 1.10 1.18 1.26 1.34 1.41 0.58 0.71 0.82 0.91 1.00 1.08 1.15 1.22 1.29 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.20 50 275 1.66 1.48 1.35 1.25 -40° 0.11 0.17 0.22 0.41 0.77 1.03 1.38 1.72 2.41 2.93 3.73 1.63 2.28 3.54 4.07 6.52 9.83 12.3 14.5 16.7 0.17 0.32 0.77 1.12 1.72 2.92 3.72 4.57 6.06 4.36 6.95 8.32 12.5 13.5 15.6 23.7 33.8 47.4 0.14 0.32 0.42 0.60 1.03 1.38 1.72 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from -40°F to 40°F since the variation in the actual factors across this range is insignificant. TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 1-1/2 ton R-404A Type EG valve at -20°F evaporator, 125 psi pressure drop across the TEV, and 60°F liquid temperature entering the TEV = 1.26 (from rating chart) x 1.43 (CF liquid temperature) x 0.91 (CF pressure drop) = 1.64 tons. Page 8 — BULLETIN 10-10 t 134a, 401A, 409A THERMOSTATIC EXPANSION VALVE CAPACITIES for REFRIGERANTS - TONS OF REFRIGERATION AIR CONDITIONING, HEAT PUMP and COMMERCIAL REFRIGERATION APPLICATIONS REFRIGERANT 401A 409A RECOMMENDED THERMOSTATIC CHARGE NOMINAL VALVE TYPES CAPACITY JC, JCP60 XC, XCP60 FC, FCP60 EVAPORATOR TEMPERATURE °F 40° 20° 0° 40° 20° 0° 40° 20° 0° F-EF-G-EG 1/8 0.15 0.15 0.14 0.16 0.16 0.15 0.15 0.15 0.14 F-EF-G-EG 1/6 0.25 0.28 0.26 0.27 0.30 0.29 0.25 0.28 0.27 F-EF-G-EG 1/4 0.31 0.35 0.33 0.34 0.37 0.36 0.32 0.35 0.33 F-EF-G-EG 1/2 0.60 0.60 0.55 0.65 0.65 0.60 0.61 0.60 0.56 F-EF-G-EG 1 1.20 1.20 1.10 1.29 1.29 1.20 1.21 1.21 1.12 F-EF-G-EG 1-1/2 1.93 1.91 1.76 2.07 2.07 1.92 1.94 1.93 1.79 F&EF(Ext)-G&EG(Ext)-S 2 2.41 2.39 2.20 2.59 2.59 2.40 2.42 2.42 2.23 S 2-1/2 3.01 2.99 2.75 3.23 3.24 3.00 3.03 3.02 2.79 S 3 3.62 3.59 3.30 3.88 3.88 3.60 3.63 3.62 3.35 S (Ext) 5 6.03 4.98 4.17 6.47 5.39 4.56 6.05 5.03 4.24 S (Ext) 6 7.23 5.98 5.01 7.76 6.47 5.47 7.26 6.04 5.09 H 3 3.62 3.59 3.04 3.88 3.88 3.31 3.63 3.62 3.08 H 4 4.82 4.79 4.05 5.18 5.18 4.42 4.84 4.83 4.11 H 5 6.03 5.98 5.06 6.47 6.47 5.52 6.05 6.04 5.14 H 8 9.04 8.97 7.59 9.70 9.71 8.29 9.08 9.06 7.71 H 12 14.1 14.0 11.8 15.1 15.1 12.9 14.2 14.1 12.0 M 15 18.7 18.5 15.1 20.1 20.1 16.5 18.8 18.7 15.3 M 20 24.1 23.9 19.5 25.9 25.9 21.3 24.2 24.2 19.8 M 25 30.1 29.9 24.3 32.3 32.4 26.6 30.3 30.2 24.7 BALANCED PORT THERMOSTATIC EXPANSION VALVES BF-EBF-SBF AAA 0.25 0.28 0.26 0.27 0.30 0.29 0.25 0.28 0.27 BF-EBF-SBF AA 0.54 0.54 0.50 0.58 0.58 0.54 0.55 0.54 0.50 BF-EBF-SBF A 1.21 1.20 1.10 1.29 1.29 1.20 1.21 1.21 1.12 BF-EBF-SBF B 2.05 2.03 1.87 2.20 2.20 2.04 2.06 2.05 1.90 BF-EBF-SBF C 3.62 3.59 3.30 3.88 3.88 3.60 3.63 3.62 3.35 EBS 5 6.12 5.60 4.82 6.57 6.06 5.26 6.15 5.66 4.89 EBS 7 8.44 7.72 6.64 9.06 8.36 7.25 8.47 7.80 6.74 EBS 9 11.2 9.72 7.80 12.0 10.5 8.52 11.2 9.81 7.92 EBS 12 16.0 14.0 10.9 17.2 15.1 11.9 16.1 14.1 11.1 O 9 10.8 10.8 9.33 11.6 11.7 10.2 10.9 10.9 9.48 O 12 14.1 14.0 12.1 15.1 15.1 13.2 14.2 14.1 12.3 O 16 18.7 18.5 16.1 20.1 20.1 17.6 18.8 18.7 16.3 O 23 27.7 30.0 24.7 29.8 32.4 27.0 27.8 30.2 25.1 O 32 38.6 41.7 34.4 41.4 45.1 37.6 38.7 42.1 34.9 O 40 48.2 52.1 43.0 51.8 56.4 47.0 48.4 52.6 43.7 V 35 33.2 45.3 45.3 36.3 42.4 42.3 33.7 42.2 41.9 V 45 54.2 53.8 42.7 58.2 58.3 46.6 54.5 54.3 43.3 V 55 66.3 65.8 52.2 71.2 71.2 57.0 66.6 66.4 53.0 W 80 102 102 75.3 110 110 82.2 103 103 76.4 W 110 137 — — 148 — — 138 — — VALVE TYPES CARTRIDGE NO. REPLACEABLE CARTRIDGE THERMOSTATIC EXPANSION VALVES Q-EQ-SQ 0 1/6 0.24 0.24 0.22 0.26 0.26 0.24 0.24 0.24 0.22 Q-EQ-SQ 1 1/4 0.54 0.54 0.50 0.58 0.58 0.54 0.55 0.54 0.50 Q-EQ-SQ 2 1/2 0.78 0.78 0.72 0.84 0.84 0.78 0.79 0.79 0.73 Q-EQ-SQ 3 1 1.21 1.20 1.10 1.29 1.29 1.20 1.21 1.21 1.12 Q-EQ-SQ 4 1-1/2 1.69 1.67 1.54 1.81 1.81 1.68 1.69 1.69 1.56 Q-EQ-SQ 5 2 2.41 2.39 2.20 2.59 2.59 2.40 2.42 2.42 2.23 Q-EQ-SQ 6 2-1/2 3.25 3.23 2.97 3.49 3.50 3.24 3.27 3.26 3.02 Balanced port replaceable cartridges, AAA, AA, A, B and C, have the same capacities as the matching nominal capacity of the BQ-EBQ-SBQ standard balanced port valves above. 134a REFRIGERANT 134a 401A 409A LIQUID TEMPERATURE ENTERING TEV °F 30° 40° 50° 60° 70° 80° 90° 100° 110° CORRECTION FACTOR, CF LIQUID TEMPERATURE 1.70 1.63 1.56 1.49 1.42 1.36 1.29 1.21 1.14 1.07 1.00 0.93 1.60 1.54 1.48 1.43 1.36 1.31 1.25 1.19 1.13 1.06 1.00 0.94 1.55 1.50 1.45 1.39 1.34 1.28 1.23 1.17 1.12 1.06 1.00 0.94 EVAPORATOR TEMPERATURE °F 40° 20° & 0° 0° 10° 20° PRESSURE DROP ACROSS TEV (psi) 20 40 60 80 100 120 140 160 CORRECTION FACTOR, CF PRESSURE DROP 0.58 0.82 1.00 1.15 1.29 1.41 1.53 1.63 0.50 0.71 0.87 1.00 1.12 1.22 1.32 1.41 120° 130° 140° 0.85 0.78 0.71 0.87 0.80 0.74 0.88 0.82 0.76 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of 0°F. However, they may be used for any evaporator temperature from 0°F to 40°F since the variation in the actual factors across this range is insignificant. TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 1-1/2 ton R-134a Type EG valve at 20°F evaporator, 100 psi pressure drop across the TEV, and 60°F liquid temperature entering the TEV = 1.91 (from rating chart) x 1.29 (CF liquid temperature) x 1.12 (CF pressure drop) = 2.76 tons. BULLETIN 10-10 — Page 9 t TEV QUICK REFERENCE GUIDE NOMINAL CAPACITY RANGE (Tons) VALVE TYPE SPECS R-22 R-134a R-404A & R-507 R-410A CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION Chatleff, SAE Flare, or ODF Solder Small brass body, externally adjustable valve available for R-22 and R-410A air conditioning and heat pump applications. This valve features a balanced port construction and contains an internal check valve to eliminate the need for an external bypass check valve on heat pump applications. Suitable for replacing OEM type TEVs with or without internal check valve on these applications. Inlet strainer is not included. RC Page 12 1 thru 6 – – 1 thru 6 ER Page 13 1 thru 12 – – 1 thru 15 ODF Solder Small brass body, externally adjustable valve available for R-22 and R-410A air conditioning and heat pump applications. This valve features a balanced port construction and is approved for bi-directional operation. Suitable for replacing OEM type TEVs without internal check valve on these applications. A 60 x 50 mesh inlet strainer is included with 3/8” inlet. Page 15 - 16 1/5 thru 3 1/8 thru 2 1/8 thru 2 – SAE Flare Small brass bar body, externally adjustable valve for small capacity refrigeration systems. SAE flare inlet connection has a removable 100 mesh strainer. Typical applications: Refrigerated cases, coolers, freezers. Page 15 - 16 1/5 thru 3 1/8 thru 2 1/8 thru 2 ODF Solder Same as the Type F valve except valve features ODF solder connections. The inlet connection has a 60 x 50 mesh insert type strainer. Typical applications: Refrigerated cases, coolers, freezers. Q 1/3 thru 5 Q 1/6 thru 2-1/2 Q 1/6 thru 3 Q BQ 1/8 thru 5-1/2 BQ 1/8 thru 3 BQ 1/8 thru 3 BQ 1/4 thru 6 SAE Flare The brass body Type Q valve is externally adjustable with a removable cartridge or orifice. The valve body, cartridge and thermostatic element is supplied as independent components. This allows body, cartridge and element to be assembled and matched to specific system requirements. Inlet connection has a 100 mesh removable strainer screen. Typical applications: Refrigeration applications and external equalized versions may be used on air conditioning. Type BQ same as above, with balanced port construction. EQ 1/3 thru 5 EQ 1/6 thru 2-1/2 EQ 1/6 thru 3 EQ EBQ 1/8 thru 5-1/2 EBQ 1/8 thru 3 EBQ 1/8 thru 3 EBQ 1/4 thru 6 Extended ODF Solder Type EQ same as the Type Q except it features extended ODF connections. A 100 mesh insert strainer is provided with the valve. Type EBQ same as Type EQ with balanced port construction and is approved for bi-directional applications. SQ 1/3 thru 5 SQ 1/6 thru 2-1/2 SQ 1/6 thru 3 SQ SBQ 1/8 thru 5-1/2 SBQ 1/8 thru 3 SBQ 1/8 thru 3 SBQ 1/4 thru 6 Extended ODF Solder Type SQ same as the Type Q valve except it features ODF solder connections and a forged brass inlet fitting with a removable 100 mesh strainer screen which can be cleaned and/or replaced without removing the valve from the line. Type SBQ is the same as Type SQ with balanced port construction and is approved for bi-directional applications. F EF Q/BQ Page 17 - 21 EQ/EBQ Page 17 - 21 SQ/SBQ Page 17 - 21 – – – – Page 10 — BULLETIN 10-10 t TEV QUICK REFERENCE GUIDE NOMINAL CAPACITY RANGE (Tons) VALVE TYPE SPECS CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION – SAE Flare Forged brass body, externally adjustable valve for small capacity refrigeration systems. Inlet connection has a removable 100 mesh strainer. Typical applications: Refrigerated cases, coolers, freezers, small capacity air conditioners. – ODF Solder Same as the Type G valve except it features ODF solder connections and a forged brass inlet fitting with a removable 100 mesh strainer which can be cleaned and/ or replaced without removing the valve from the line. – SAE Flare Same physical size as the Type F valve with SAE flare connections except it features a balanced port construction. Inlet connection has a removable 100 mesh strainer. Typical applications: Small capacity refrigeration that operates over widely varying operating conditions. 1/8 thru 3 – Extended ODF Solder Same as the Type BF valve except it features ODF solder connections and a forged brass inlet fitting with a removable 100 mesh strainer which can be cleaned and/or replaced without removing the valve from the line. 1/8 thru 3 1/8 thru 3 – Extended ODF Solder Same as the Type BF valve except it features extended ODF connections. A 100 mesh insert strainer is provided with the valve. 2 thru 10 2 thru 6 2 thru 7 – ODF Solder Brass bar body, externally adjustable valve. Inlet has a permanent 12 mesh strainer. General purpose valve for air conditioning and refrigeration applications. 8 thru 20 5 thru 12 6 thru 13 – Extended ODF Solder Same physical size as the Type S valve except it features extended ODF connections. This valve features a balanced port construction which, depending on its capacity, makes it suitable for bi-directional operation. See page 28 for details. R-22 R-134a R-404A & R-507 Page 22 1/5 thru 3 1/8 thru 2 1/8 thru 2 Page 23 1/5 thru 3 1/8 thru 2 1/8 thru 2 Page 24 1/8 thru 5-1/2 1/8 thru 3 1/8 thru 3 Page 25 - 26 1/8 thru 5-1/2 1/8 thru 3 Page 25 - 26 1/8 thru 5-1/2 Page 27 Page 28 R-410A G EG BF SBF EBF S EBS BULLETIN 10-10 — Page 11 t TEV QUICK REFERENCE GUIDE NOMINAL CAPACITY RANGE (Tons) VALVE TYPE SPECS CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION 20 thru 60 ODF Solder Brass bar body, externally adjustable valve. Inlet has a permanent 12 mesh strainer. This valve features a balanced port construction, and it is suitable for both air conditioning and refrigeration applications. Optional bi-directional feature available, please contact Sporlan Division of Parker for details. – ODF Solder or FPT Flange Brass bar body, externally adjustable valve with flange connections. Inlet flange bushing has a permanent 16 mesh strainer. The FPT flange connection requires the K-1178 adapter kit. This valve provides the smallest capacity TEVs with flange connections and it is suitable for both air conditioning and refrigeration applications. ODF Solder or FPT Flange Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type provides valve capacities greater than the Type H and it is suitable for air conditioning and refrigeration applications. Flanges for the Type M valve are interchangeable with the Type V valve. ODF Solder or FPT Flange Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type features a dual port semi-balanced design. This valve type provides valve capacities greater than the Type M and is suitable for air conditioning and refrigeration applications. Flanges for the Type V are interchangeable with the Type M. ODF Solder Flange Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type features a dual port semi-balanced design and it is primarily for large capacity chillers. This valve type provides the largest valve capacities available for flange connection TEVs. R-22 R-134a R-404A & R-507 R-410A Page 29 - 30 15 thru 70 9 thru 40 9 thru 45 Page 31 5-1/2 thru 20 3 thru 12 3 thru 12 O H M Page 32 21 thru 42 15 thru 25 15 thru 30 – V Page 33 52 thru 100 35 thru 55 Page 34 135 & 180 80 & 110 38 thru 70 – W – – Page 12 — BULLETIN 10-10 t TYPE RC For Refrigerants 22, 410A Chatleff, SAE Flare & ODF Solder Connections Sporlan Type RC valve is a small brass body, externally adjustable valve with balanced port construction. The RC valves are available for replacement of types CBI and CBBI valves. These valves contain internal check valves to allow reverse flow on heat pump applications. This eliminates the need for an external check valve piped around the TEV for reverse flow. The RC valve can be used on heat pump and air conditioning (cooling only) applications. This allows you to reduce inventory by using the same valve to replace the I, BI and BBI valves. The RC valves can even be used to replace the RI valve (nonRPB versions only). Outlet Connections 1/2” SAE, 1/2” ODF, 5/8” ODF Type RC Mating Distributors (See Bulletin 20-10) D260, D262, 1603, 1605, 1606, 1608, 1620, 1622, 1650(R), 1651(R) For complete details of construction, see page 35. 22 (V) 407C (N) 407A (V) 422D (V) 410A (Z) RCVE-1-GA RCVE-1-1/2-GA RCVE-2-GA RCVE-3-GA RCVE-4-GA RCVE-5-GA RCVE-6-GA RCZE-1-GA RCZE-1-1/2-GA RCZE-2-GA RCZE-3-GA RCZE-4-GA RCZE-5-GA RCZE-6-GA 1/4 SAE 1/4 ODF 1/4 ODF 1 1-1/2 2 3 4 5 6 1 1-1/2 2 3 4 5 6 43 INLET OUTLET 3/8 SAE 3/8 ODF 1/2 SAE 1/2 ODF 1/2 ODF 1/2 SAE 1/2 ODF 1/2 ODF 1/2 SAE 5/8 ODF 3/8 ODF 1/2 ODF 1/2 ODF 1/2 ODF 1/2 ODF 5/8 ODF SHIPPING WEIGHT Blue figures are standard and will be furnished unless otherwise specified. VGA 30 in. 760 mm 45 CONNECTIONS - Inches Q SAE Flare/ R ODF Solder NET WEIGHT STANDARD TUBING LENGTH THERMOSTATIC CHARGES AVAILABLE EXTERNAL EQUALIZER W, E VALVE TYPE THERMOSTATIC ELEMENT SIZE NO. REFRIGERANT (Sporlan Code) NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 43 (R-22) AND NO. 45 (R-410A), KNIFE EDGE JOINT 1-1/4 lbs. 1-1/2 lbs. 568 g 680 g ZGA QValves are also available as special order with Chatleff connections. WValves with SAE inlet and outlet fittings are available only with the 1/4” SAE flare external equalizer; valves with ODF fittings are available only with the 1/4” ODF external equalizer. EValves with Chatleff fittings are available only with the 1/8” OD X 24” long tube with flare and nut external equalizer. RODF Solder on Type RC valves indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. 1.94” DIMENSIONS Cap Tube 30” CONNECTIONS - Inches VALVE TYPE FITTING SIZE 3/8 SAE 1/2 SAE RC 3/8 ODF 1/2 ODF 5/8 ODF RC Chatleff Fitting A B C D 1.92 1.89 1.92 1.98 – 1.89 – 1.92 1.45 1.45 1.53 1.71 – – 0.31 0.40 0.50 – 1.63 1.63 1.90 1.90 1.90 E C 3.66” BULB SIZES - Inches STANDARD CHARGES GA 410A 0.75 OD x 2.00 1.81” A REFRIGERANT 22 C 2.30” 1/4” ODF External Equalizer Connection D Top View B 30° Chatleff Fitting Option E BULLETIN 10-10 — Page 13 t TYPE ER For Refrigerants 22, 410A ODF Solder Connections Sporlan Type ER valve is a small brass bar body, externally adjustable with ODF solder connections, a replaceable thermostatic element, and balanced port construction. The ER valve is designed for R-22 and R-410A air conditioning and heat pump applications and is ideal for replacing I, BI, BBI and RI (non-RPB version only) valves. This valve type has two body styles: a small body which provides capacities up to 8 tons R-22 and R-410A, and a large body style which extends capacities to 12 tons R-22 and 15 tons R-410A. Replacement elements available for these valves are the following: Refrigerant 22, Element Kit Number KT-43-VGA or VCP100 for the small body style and KT-45-5-VGA or VCP100 for the large body, and Refrigerant 410A, Element Kit Number KT-45-ZGA or ZCP180 for the small body style and KT-45-5-ZGA or ZCP180 for the large body style. Type ER This valve may also be applied in bi-directional applications. Outlet Connections 1/2” ODF, 5/8” ODF, 7/8” ODF, 1-1/8” ODF Mating Distributors (See Bulletin 20-10) D260, D262, 1620, 1622, 1112, 1113, 1115, 1116, 1135, 1136, 1137, 1651(R), 1653(R), 1655(R) For complete details of construction, see page 35. 410A (Z) 1 1-1/2 2 3 4 5 6 8 10 12 1 1-1/2 2 3 4 5 6 8 12-1/2 15 43 STANDARD TUBING LENGTH THERMOSTATIC CHARGES AVAILABLE Not all connection combinations are available. INLET OUTLET 3/8 1/2 60 in. 1.5 m 45-5 3/8 or 1/2 5/8 3/8 45-5 1 lb. 454 g 1-1/2 lbs. 680 g 1 lb. 454 g 1-1/2 lbs. 680 g 1/2 or 5/8 VGA VCP100 1/2 45 SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) ERVE-1 ERVE-1-1/2 ERVE-2 ERVE-3 ERVE-4 ERVE-5 ERVE-6 ERVE-8 ERVE-10 ERVE-12 ERZE-1 ERZE-1-1/2 ERZE-2 ERZE-3 ERZE-4 ERZE-5 ERZE-6 ERZE-8 ERZE-12-1/2 ERZE-15 CONNECTIONS -Inches Q ODF Solder NET WEIGHT 22 (V) VALVE TYPE THERMOSTATIC ELEMENT SIZE NO. REFRIGERANT (Sporlan Code) NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 43 (R-22), NO. 45 (R-410A), AND NO. 45-5, KNIFE EDGE JOINT 1/2, 5/8 or 7/8 5/8 or 7/8 7/8 1/2 1/2 or 5/8 ZGA ZCP180 60 in. 1.5 m 3/8 or 1/2 1/2, 5/8 or 7/8 1/2 5/8 or 7/8 7/8 5/8 1-1/8 QODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. Page 14 — BULLETIN 10-10 t TYPE ER For Refrigerants 22, 410A ODF Solder Connections TYPE ER with NUMBER 43 and 45 ELEMENT 0.31” 7.9 mm 1.94” 49.3 mm 30° 1.81“ 50.0 mm E .253/.256” 6.43/6.50 mm Top View DIMENSIONS REFRIGERANT 22 410A Cap Tube 60” F 3.53” 89.7 mm 2.17” 55.1 mm Diameter 1.94” 49.3 mm D C A - CONNECTIONS NOMINAL CAPACITY 1-1/2 2 3 4 5 3 4 5 6 4 5 6 8 1/2” 5/8” 1/2” 7/8” 6 8 7/8” 5/8” 8 B BULB SIZES FITTING SIZE INLET OUTLET 3/8” 1.83” 46.5 mm 1-1/8” A B C D E 2.42” 2.51” 0.31” 0.40” .377/.381” .502/.506” 61.5 63.8 7.9 10.2 9.58/9.68 12.8/12.9 mm mm mm mm mm mm 2.51” 63.8 2.35” mm 0.40” 10.2 59.7 mm 2.41” mm 61.2 mm REFRIGERANT 22 410A 0.50” OD x 3.00” 12.7 mm x 76.2 mm 0.75” OD x 2.00” 19.1 mm x 50.8 mm STANDARD CHARGES F VCP100, ZCP180 GA 0.50” .627/.632” 12.7 mm .502/.506” 15.9/16.1 mm 12.8/12.9 mm 0.78” .877/.882” 19.8 22.3/22.4 mm mm .877/.882” 0.78” 22.3/22.4 19.8 2.35” 2.41” 0.50” mm .627/.632” mm 59.7 61.2 12.7 0.91” 15.9/16.1 1.128/1.135” mm mm mm mm 23.1 28.7/28.8 mm mm TYPE ER with NUMBER 45-5 ELEMENT 1.94” 49.3 mm 30° 1.90“ 48.3 mm 0.31“ 7.9 mm DIMENSIONS E REFRIGERANT 22 10 12 410A 12-1/2 15 D .253/.256” 6.43/6.50 mm - CONNECTIONS NOMINAL CAPACITY Cap Tube 60” 3.79” 96.3 mm 2.30” 58.4 mm F C Diameter 1.94” 49.3 mm FITTING SIZE INLET OUTLET 7/8” 5/8” 1-1/8” A 1.83” 46.5 mm A B C D E F .877/.882” 0.78” 22.3/22.4 19.8 mm 2.48” 2.51” 0.50” mm .627/.632” 15.9/16.1 63.0 63.8 12.7 1.128/1.135” mm mm mm mm 0.91” 23.1 28.7/28.8 mm mm B BULLETIN 10-10 — Page 15 t TYPE F & EF For Refrigerants 22, 134a, 404A, 507 SAE Flare & ODF Solder Connections freezers where space is limited and an external adjustment is desired. Sporlan Type F with SAE flare connections or Type EF with ODF solder connections are small brass bar body valves with identical internal construction and replaceable thermostatic elements. The Type F valve has a removable 100 mesh strainer as a standard feature. The Type EF has a 60 x 50 mesh insert strainer. These valves are designed for small refrigeration systems such as refrigerated cases, coolers, and Type EF Outlet Connections 3/8” SAE, 1/2” SAE, 3/8” ODF, 1/2” ODF Mating Distributors (See Bulletin 20-10) D260, D262, 1603, 1605, 1606, 1608, 1650(R) Type F For complete details of construction, see page 35. Internal External Internal External Equalizer Equalizer Equalizer Equalizer FV-1/5 FVE-1/5 EFV-1/5 EFVE-1/5 1/5 FV-1/3 FVE-1/3 EFV-1/3 EFVE-1/3 1/3 FV-1/2 FVE-1/2 EFV-1/2 EFVE-1/2 1/2 FV-1 FVE-1 EFV-1 EFVE-1 FV-1-1/2 – FV-2-1/2 – 134a (J) 12 (F) 401A (X) 409A (F) 502 (R) 408A (R) 402A (L) – EFV-2-1/2 – EFVE-2 – EFVE-3 1-1/2 2 EFJE-1/8 1/8 FJ-1/6 FJE-1/6 EFJ-1/6 EFJE-1/6 1/6 FJ-1/4 FJE-1/4 EFJ-1/4 EFJE-1/4 1/4 FJ-1/2 FJE-1/2 EFJ-1/2 EFJE-1/2 1/2 FJ-1 FJE-1 EFJ-1 EFJE-1 FJE-1-1/2 EFJ-1-1/2 FJE-2 – EFJE-1-1/2 EFJE-2 EFS-1/8 EFSE-1/8 1/8 FSE-1/6 EFS-1/6 EFSE-1/6 1/6 FS-1/4 FSE-1/4 EFS-1/4 EFSE-1/4 1/4 FS-1/2 FSE-1/2 EFS-1/2 EFSE-1/2 1/2 FS-1 FSE-1 EFS-1 EFSE-1 FS-1-1/2 FSE-1-1/2 EFS-1-1/2 EFSE-1-1/2 1 FPE-1/8 EFP-1/8 EFPE-1/8 1/8 FPE-1/6 EFP-1/6 EFPE-1/6 1/6 FP-1/4 FPE-1/4 EFP-1/4 EFPE-1/4 1/4 FP-1/2 FPE-1/2 EFP-1/2 EFPE-1/2 1/2 FP-1 FPE-1 EFP-1 EFPE-1 FP-1-1/2 FPE-1-1/2 EFP-1-1/2 EFPE-1-1/2 – EFPE-2 1/4 or 3/8 Q 3/8 or 1/2 3/8 E 1/2 1/4 or 3/8 Q 3/8 or 1/2 3/8 E 1/2 1/4 or 3/8 Q 3/8 or 1/2 3/8 E 1/2 1/4 or 3/8 Q 3/8 or 1/2 3/8 E 1/2 2 FP-1/6 FPE-2 C Z ZP40 1-1/2 FP-1/8 – 30 in. 760 mm 2 FSE-1/8 EFSE-2 OUTLET 1 lb. 454 g 1-1/2 lbs. 680 g C 1-1/2 FS-1/6 – INLET 1 FS-1/8 FSE-2 Blue figures are standard and will be furnished unless otherwise specified. 3 EFJ-1/8 FJ-1-1/2 CONNECTIONS - Inches SAE Flare / W ODF Solder C Z ZP40 2-1/2 FJE-1/8 – 507 (P) – – FJ-1/8 – 404A (S) FVE-1-1/2 EFV-1-1/2 EFVE-1-1/2 FVE-2 1 STANDARD TUBING LENGTH ODF Solder SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) SAE Flare NET WEIGHT 22 (V) TYPE EF THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) TYPE F NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 43, KNIFE EDGE JOINT 1 1-1/2 C Z ZP40 2 QThe 3/8” SAE inlet fitting has a long taper on the flare surface. A 3/8” x 1/4” reducing flare nut will allow 1/4” OD tubing to be attached to this fitting. WODF Solder on Type EF valves indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. ENominal 1 ton and larger F valves for R-134a, R-404A and R-507 type refrigerants, and nominal 1-1/2 ton and larger for R-22 refrigerant require 3/8” SAE Flare or 3/8” ODF inlet, minimum. Page 16 — BULLETIN 10-10 t TYPE F & EF For Refrigerants 22, 134a, 404A, 507 SAE Flare & ODF Solder Connections SAE FLARE DIMENSIONS SAE CONNECTIONS - Inches FITTING SIZE 1/4 SAE Elbow 3/8 SAE Elbow 3/8 SAE 1/2 SAE A 1.05 1.27 – – 1.94 B – – 1.61 1.80 C 1.34 0.98 – – BULB SIZES - Inches REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.50 OD x 3.00 Z & ZP Series 0.50 OD x 3.00 – 0.50 OD x 3.00 1/4 SAE Inlet Strainer P/N 3008-000 3/8 SAE Inlet Strainer P/N 1538-000 3.76 2.02 External 1/4 SAE Equalizer Fitting 60° C B A 1.54 Top View ODF SOLDER DIMENSIONS 1.94 ODF CONNECTIONS - Inches FITTING SIZE 1/4 ODF 3/8 ODF 1/2 ODF A 1.69 1.69 – B – 1.35 1.35 C 0.31 0.31 0.40 C BULB SIZES - Inches C REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.50 OD x 3.00 Z & ZP Series 0.50 OD x 3.00 – 0.50 OD x 3.00 3.76 2.43 2.02 3/8 ODF Insert Strainer P/N 1524-000 30° 1/4” ODF External Equalizer Connection A 1.81 Top View 1/4 ODF Insert Strainer P/N 1543-002 B BULLETIN 10-10 — Page 17 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections *Type Q, EQ, and SQ are not approved for R-410A applications. The Sporlan Q & BQ series are replaceable cartridge style valves designed for small refrigeration systems, such as refrigerated cases, coolers, and freezers. The externally equalized versions of these valves are ideal for air conditioning and heat pump systems. BQ valves are balanced ported, engineered specifically for systems with a wide range of operating conditions and may be applied on bi-directional applications. Q & BQ valves are supplied as three individual component parts: the thermostatic element, the valve body, and the replaceable cartridge or orifice. The interchangeable nature of the Q & BQ family make it ideal for reducing inventory, while increasing valve options — so, the right valve is always on hand. BODY FEATURES Q & BQ brass body type valves feature Sporlan’s traditional knife edge, metal-to-metal thermostatic element to valve body construction, which ensures a leak-proof joint. SELECTIVE CHARGES Sporlan selective thermostatic charges are specifically designed for low temperature, medium temperature, and air conditioning applications. The elements are manufactured with a large flat diaphragm to reduce diaphragm stresses and provide precise control. And, because Q & BQ valve bodies and thermostatic elements are supplied as independent components, the installer is able to select the best possible thermostatic charge for the application. INTERNAL PORT DESIGN Refrigerant flow through the valve port opposes the pin movement in all type Q and BQ valves. This provides improved stability at light loads, when the pin modulates to a position close to the port. Additionally, charge migration, is reduced or eliminated by the Q & BQ valve design. By engineering the liquid flow to enter through the top of the valve body, the liquid refrigerant warms the thermostatic element and minimizes the potential for charge migration. TYPE Conventional Port TYPE Balanced Port For complete details of construction, see page 35. SELECTING COMPONENTS BODY Flare Connections Extended Solder Connections Q Extended Solder Connections with Forged Inlet and Replaceable Strainer EQ SAE (Internally Equalized) SQ ODF (Internally Equalized) QE SAE (Externally Equalized) ODF (Internally Equalized) EQE EBQ BQ ODF (Internally Equalized) SAE (Internally Equalized) BQE SAE (Externally Equalized) SQE ODF (Externally Equalized) EBQE ODF (Externally Equalized) ODF (Externally Equalized) SBQ ODF (Internally Equalized) SBQE ODF (Externally Equalized) Page 18 — BULLETIN 10-10 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections *Type Q, EQ, and SQ are not approved for R-410A applications. CARTRIDGE Q CARTRIDGE SERVICE KIT PART NUMBER 184000 Top surface is color coded to identify cartridge capacity. 0 2 QC-0 - Red Qty. 3 SPORLAN 0 INDIVIDUAL REPLACEMENT PARTS PART NUMBER SIZE QC-1 - Yellow Qty. 5 4 QC-3 - Blue Qty. 5 QC-4 - Pink Qty. 3 Oil Bottle 6 QC-5 - Black Qty. 3 QC-6 - White Qty. 3 Pushrods Qty. 4 CAPACITIES COLOR CODE CARTRIDGE and I.D. TAG QC-0 0 Red QC-1 1 Yellow QC-2 2 Green QC-3 3 Blue QC-4 4 Pink QC-5 5 Black QC-6 6 White MISCELLANEOUS PARTS OB-1 Oil Bottle (With Oil) AW-1 4 mm Allen Wrench Q Cartridge Service Kit CSK-1 (Empty) Q Cartridge Service Kit 184000 (Complete as noted above) QC-2 - Green Qty. 5 3 4 mm Allen Wrench 5 Identification tag with cartridge number (bends around capillary tubing). 2 NOMINAL CAPACITY (TONS) of SPORLAN VALVE TO BE REPLACED R-22, R-422D 1/4 1/3 1/2 3/4 1 1-1/2 2 2-1/2 3 4 5 R-12 1/8 1/6 1/4 1/2 1 1-1/2 2 2-1/2 3 R-134a R-401A R-402A R-404A 1/8 1/6 1/8 1/6 1/8 1/6 1/4 1/4 1/2 1 R-410A Q VALVE CARTRIDGE SIZE COLOR CODE R-502 R-507 1/8 1/6 1/8 1/6 1/8 1/6 0 Red 1/4 1/4 1/4 1/4 1 Yellow 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 2 3 Green Blue 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 4 Pink 2 2-1/2 3 2 2-1/2 3 2 2 2 2 5 Black 3 3 3 3 6 White NOT APPROVED Capacity code on cartridge. 1 BQ CARTRIDGE SERVICE KIT PART NUMBER 184007 Top surface is color coded to identify cartridge capacity. S B BQC-B - Pink Qty. 2 N C Identification tag with cartridge number (bends around capillary tubing). INDIVIDUAL REPLACEMENT PARTS SIZE BQC-B - Pink Qty. 1 Oil Bottle RL PO A SPORLAN AAA PART NUMBER BQ Cartridge Tool BQC-A - Blue Qty. 4 B AAA BQC-AA - Yellow Qty. 4 A Capacity code on cartridge. AA AAA BQC-AAA - Red Qty. 2 BQ BQC-C - White Qty. 2 CAPACITIES COLOR CODE CARTRIDGE and I.D. TAG* BQC-AAA AAA Red BQC-AA AA Yellow BQC-A A Blue BQC-B B Pink BQC-C C White MISCELLANEOUS PARTS OB-1 Oil Bottle (With Oil) 4444-000 BQ Cartridge Tool BQ Cartridge Service Kit CSK-1 (Empty) BQ Cartridge Service Kit 184007 (Complete as noted above) *BQC with B15 (15% bleed port) is available. NOMINAL CAPACITY (TONS) of SPORLAN VALVE TO BE REPLACED R-12 R-22, R-422D R-134a R-401A R-402A R-404A R-410A BQ VALVE CARTRIDGE R-502 R-507 SIZE COLOR CODE 1/8 1/8 1/8 1/8 1/8 1/8 1/4 1/8 1/8 AAA Red thru 1/5 thru 1/3 thru 1/5 thru 1/5 thru 1/5 thru 1/5 thru 1/3 thru 1/5 thru 1/5 1/4 1/2 1/4 1/4 1/4 1/4 1/2 1/4 1/4 AA Yellow thru 1/3 thru 2/3 thru 1/3 thru 1/3 thru 1/3 thru 1/3 thru 3/4 thru 1/3 thru 1/3 1/2 3/4 1/2 1/2 1/2 1/2 1 1/2 1/2 A Blue thru 1 thru 1-1/2 thru 1 thru 1 thru 1 thru 1 thru 1-3/4 thru 1 thru 1 1-1/4 1-3/4 1-1/4 1-1/4 1-1/4 1-1/4 2 1-1/4 1-1/4 B Pink thru 1-3/4 thru 3 thru 1-3/4 thru 1-3/4 thru 2 thru 2 thru 3-1/2 thru 2 thru 2 3-1/4 2-1/4 2-1/4 4 2-1/4 2-1/4 2 thru 3 2 thru 3 2 thru 3 C White thru 5-1/2 thru 3 thru 3 thru 6 thru 3 thru 3 BULLETIN 10-10 — Page 19 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections *Type Q, EQ, and SQ are not approved for R-410A applications. ELEMENT SPORLAN REFRIGERANT CODE Date Code (by week and year of manufacture) R-410A ELEMENT LABEL COLOR CODE F V J X L S V N R F Z R P R-12 R-22, R-422D R-134a R-401A R-402A R-404A R-407A R-407C R-408A R-409A R-410A R-502 R-507 Yellow Green Blue Pink Sand Orange Green Light Brown Purple Yellow Pink Purple Teal 2710 KT-45-ZGA E CO • WASHIN ALV GT NV ON LA ,M OR MADE IN O U.S. of A. SP Capillary Tube Length (standard = 5 ft.) Bulb 45 ZGA KT Element Label – 45 – Element Size Number Abbreviation for “Kit” Z GA Refrigerant Code Q Thermostatic Charge Q While many new refrigerants and refrigerant blends have a unique letter code, many use the same thermostatic element as the traditional refrigerant they replace. Refer to the table below to select the correct thermostatic element. RECOMMENDED THERMOSTATIC ELEMENTS** REFRIGERANT APPLICATION 12 Air Conditioning Commercial Refrigeration 50°F to -10°F Low Temperature Refrigeration 0°F to -40°F X – – – – – X – – – X X – – – – 22, 422D – X X – – – – X – – – – X X – – 134a 401A 402A 404A 407A 407C 408A 409A 410A 502 507 X – – – – – X – – – – – – – – – X – – – – – X – – – – – – – – – – – – – – – – – – X – – – – X X – – – X – – – – X – – – – – X X – X X – – – – X – – – – – – – – – X X – – – – X – – – – – – – – – – – X – – – – X – – – – – X X X – – – – – X – – – – – – – – – – – – – X X – – – – – – – – – – – – – X – – – – X – – – – – X X – – – – – – – – – X – – – – X X THERMOSTATIC ELEMENT SYSTEM MOP psig KT-43-JCP60 KT-43-VCP100 KT-43-VGA KT-43-SCP115 KT-45-ZGA KT-45-ZCP180 KT-43-JC KT-43-VC KT-43-SC KT-43-PC KT-43-JZ KT-43-JZP KT-43-VZ KT-43-VZP40 KT-43-SZ KT-43-SZP 50 90 – 105 – 170 – – – – – 12 – 30 – 35 **APPLICATION FACTORS: 1. The Sporlan Type ZP thermostatic charges have essentially the same characteristics as the conventional Z cross charges with one exception: they produce a pressure limit or MOP. The ZP charges are not intended as replacements for the Z charges - they should only be used where a definite pressure limit is required to prevent motor overloading. 2. All air conditioning and heat pump charges are intended for use with externally equalized valves. 3. For dual temperature applications, use the “C” charge. 4. The “C” charge may be used on applications down to -30°F on R-22, R-404A and R-507. 5. R-410A elements for use with BQ, EBQ, and SBQ only. ORDERING INSTRUCTIONS VALVE NOMENCLATURE BODY QE Valve Type Q, EQ, SQ Internally Equalized QE, EQE, SQE Externally Equalized – 3/8 x 1/2 x 1/4 SAE – QC – Connection Size and Style: Inlet x Outlet x External Equalizer BODY BQE Valve Type BQ, EBQ, SBQ Internally Equalized BQE, EBQE, SBQE Externally Equalized CARTRIDGE Cartridge Type ELEMENT 2 – KT-43 – V C Cartridge Size Element Kit KT-43 Refrigerant Code (See above) Thermostatic Charge CARTRIDGE Cartridge Type Cartridge Size 5’ Capillary Tube Length ELEMENT – 3/8 x 1/2 x 1/4 SAE – BQC – AA – KT-43 – Connection Size and Style: Inlet x Outlet x External Equalizer – Element Kit KT-43 or KT-45 (R-410A only) V C Refrigerant Code (See above) Thermostatic Charge – 5’ Capillary Tube Length Page 20 — BULLETIN 10-10 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections *Type Q, EQ, and SQ are not approved for R-410A applications. 502 (R) 408A (R) 507 (P) 402A (L) SQ-0 SQ-1 SQ-2 SQ-3 SQ-4 SQ-5 SQ-6 SQ-0 SQ-1 SQ-2 SQ-3 SQ-4 SQ-5 SQ-6 SQ-0 SQ-1 SQ-2 SQ-3 SQ-4 SQ-5 SQ-6 SQ-0 SQ-1 SQ-2 SQ-3 SQ-4 SQ-5 SQ-6 SQE-0 SQE-1 SQE-2 SQE-3 SQE-4 SQE-5 SQE-6 SQE-0 SQE-1 SQE-2 SQE-3 SQE-4 SQE-5 SQE-6 SQE-0 SQE-1 SQE-2 SQE-3 SQE-4 SQE-5 SQE-6 SQE-0 SQE-1 SQE-2 SQE-3 SQE-4 SQE-5 SQE-6 1/3 3/4 1 1-1/2 2-1/2 3-1/2 5 1/6 1/4 1/2 1 1-1/2 2 2-1/2 1/6 1/4 1/2 1 1-1/2 2 3 1/6 1/4 1/2 1 1-1/2 2 3 STANDARD TUBING LENGTH 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 SHIPPING WEIGHT 404A (S) EQE-0 EQE-1 EQE-2 EQE-3 EQE-4 EQE-5 EQE-6 EQE-0 EQE-1 EQE-2 EQE-3 EQE-4 EQE-5 EQE-6 EQE-0 EQE-1 EQE-2 EQE-3 EQE-4 EQE-5 EQE-6 EQE-0 EQE-1 EQE-2 EQE-3 EQE-4 EQE-5 EQE-6 1 lb. 454 g 1-1/2 lbs. 680 g SHIPPING WEIGHT 12 (F) 401A (X) 409A (F) EQ-0 EQ-1 EQ-2 EQ-3 EQ-4 EQ-5 EQ-6 EQ-0 EQ-1 EQ-2 EQ-3 EQ-4 EQ-5 EQ-6 EQ-0 EQ-1 EQ-2 EQ-3 EQ-4 EQ-5 EQ-6 EQ-0 EQ-1 EQ-2 EQ-3 EQ-4 EQ-5 EQ-6 NET WEIGHT 134a (J) QE-0 QE-1 QE-2 QE-3 QE-4 QE-5 QE-6 QE-0 QE-1 QE-2 QE-3 QE-4 QE-5 QE-6 QE-0 QE-1 QE-2 QE-3 QE-4 QE-5 QE-6 QE-0 QE-1 QE-2 QE-3 QE-4 QE-5 QE-6 CONNECTIONS Inches Blue figures are standard and will be furnished unless otherwise specified. NET WEIGHT 407C (N) 407A (V) 422D (V) Q-0 Q-1 Q-2 Q-3 Q-4 Q-5 Q-6 Q-0 Q-1 Q-2 Q-3 Q-4 Q-5 Q-6 Q-0 Q-1 Q-2 Q-3 Q-4 Q-5 Q-6 Q-0 Q-1 Q-2 Q-3 Q-4 Q-5 Q-6 Refer to Recommended Thermostatic Elements on Page 19 22 (V) Internal External Internal External Internal External Equalizer Equalizer Equalizer Equalizer Equalizer Equalizer Q W Q W Q W NOMINAL CAPACITY Tons of Refrigeration REFRIGERANT (Sporlan Code) Extended ODF Solder CARTRIDGE BODY TYPE - CARTRIDGE SAE Flare THERMOSTATIC CHARGES AVAILABLE Q SPECIFICATIONS ELEMENT SIZE NO. 43, KNIFE EDGE JOINT 1 lb. 454 g 1-1/2 lbs. 680 g INLET x OUTLET Q & QE Only 1/4 x 3/8 SAE 90° Angle Inlet or 1/4 x 1/2 SAE 90° Angle Inlet or 3/8 x 1/2 SAE 90° Angle Inlet EQ Only 3/8 x 1/2 ODF Straight Thru 5 ft. 1.5 m EQE Only 3/8 x 1/2 ODF Straight Thru or 3/8 x 5/8 ODF Straight Thru or 1/2 x 5/8 ODF Straight Thru or 1/2 x 7/8 ODF Straight Thru SQ & SQE Only 3/8 x 1/2 ODF 90° Angle Inlet 22 (V) 407C (N) 407A (V) 422D (V) 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 410A (Z) 507 (P) 402A (L) BQ-AAA BQ-AA BQ-A BQ-B BQ-C BQ-AAA BQ-AA BQ-A BQ-B BQ-C BQ-AAA BQ-AA BQ-A BQ-B BQ-C BQ-AAA BQ-AA BQ-A BQ-B BQ-C BQ-AAA BQ-AA BQ-A BQ-B BQ-C BQE-AAA BQE-AA BQE-A BQE-B BQE-C BQE-AAA BQE-AA BQE-A BQE-B BQE-C BQE-AAA BQE-AA BQE-A BQE-B BQE-C BQE-AAA BQE-AA BQE-A BQE-B BQE-C BQE-AAA BQE-AA BQE-A BQE-B BQE-C EBQ-AAA EBQ-AA EBQ-A EBQ-B EBQ-C EBQ-AAA EBQ-AA EBQ-A EBQ-B EBQ-C EBQ-AAA EBQ-AA EBQ-A EBQ-B EBQ-C EBQ-AAA EBQ-AA EBQ-A EBQ-B EBQ-C EBQ-AAA EBQ-AA EBQ-A EBQ-B EBQ-C EBQE-AAA EBQE-AA EBQE-A EBQE-B EBQE-C EBQE-AAA EBQE-AA EBQE-A EBQE-B EBQE-C EBQE-AAA EBQE-AA EBQE-A EBQE-B EBQE-C EBQE-AAA EBQE-AA EBQE-A EBQE-B EBQE-C EBQE-AAA EBQE-AA EBQE-A EBQE-B EBQE-C SBQ-AAA SBQ-AA SBQ-A SBQ-B SBQ-C SBQ-AAA SBQ-AA SBQ-A SBQ-B SBQ-C SBQ-AAA SBQ-AA SBQ-A SBQ-B SBQ-C SBQ-AAA SBQ-AA SBQ-A SBQ-B SBQ-C SBQ-AAA SBQ-AA SBQ-A SBQ-B SBQ-C SBQE-AAA SBQE-AA SBQE-A SBQE-B SBQE-C SBQE-AAA SBQE-AA SBQE-A SBQE-B SBQE-C SBQE-AAA SBQE-AA SBQE-A SBQE-B SBQE-C SBQE-AAA SBQE-AA SBQE-A SBQE-B SBQE-C SBQE-AAA SBQE-AA SBQE-A SBQE-B SBQE-C AAA 1/8 thru 1/3 AA 1/2 thru 2/3 A 3/4 thru 1-1/2 B 1-3/4 thru 3 C 3-1/4 thru 5-1/2 AAA 1/8 thru 1/5 AA 1/4 thru 1/3 A 1/2 thru 1 B 1-1/4 thru 1-3/4 C 2 thru 3 AAA 1/8 thru 1/5 AA 1/4 thru 1/3 A 1/2 thru 1 B 1-1/4 thru 2 C 2-1/4 thru 3 AAA 1/4 thru 1/3 AA 1/2 thru 3/4 A 1 thru 1-3/4 B 2 thru 3-1/12 C 4 thru 6 AAA 1/8 thru 1/5 AA 1/4 thru 1/3 A 1/2 thru 1 B 1-1/4 thru 2 C 2-1/4 thru 3 STANDARD TUBING LENGTH THERMOSTATIC CHARGES AVAILABLE Internal External Internal External Internal External Equalizer Equalizer Equalizer Equalizer Equalizer Equalizer Q W Q W Q W Refer to Recommended Thermostatic Elements on Page 19 REFRIGERANT (Sporlan Code) Extended ODF Solder CARTRIDGE BODY TYPE - CARTRIDGE SAE Flare NOMINAL CAPACITY Tons of Refrigeration BQ SPECIFICATIONS ELEMENT SIZE NO. 43 (R-22) and N0. 45 (R-410A), KNIFE EDGE JOINT CONNECTIONS Inches Blue figures are standard and will be furnished unless otherwise specified. INLET x OUTLET BQ & BQE 1/4 x 3/8 SAE 90° Angle Inlet or 1/4 x 1/2 SAE 90° Angle Inlet or 3/8 x 1/2 SAE E 90° Angle Inlet EBQ Only 3/8 x 1/2 ODF R Straight Thru 5 ft. 1.5 m EBQE Only 3/8 x 1/2 ODF R Straight Thru or 3/8 x 1/2 ODF R 90° Angle Inlet or 1/2 x 5/8 ODF R Straight Thru or 1/2 x 7/8 ODF R Straight Thru SBQ & SBQE Only 3/8 x 1/2 ODF R 90° Angle Inlet Q Valves listed in the column are NOT AVAILABLE with MOP type air conditioning charges. W Standard External Equalizer 1/4” SAE (Q and BQ Body), 1/4” ODF (SQ, SBQ, EQ and EBQ Body). E The 3/8” SAE inlet fitting has a long taper on the flare surface. A 3/8” x 1/4” reducing flare nut will allow 1/4” OD tubing to be attached to this fitting. R ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. BULLETIN 10-10 — Page 21 t TYPE Q & BQ For Refrigerants 22, 134a, 404A, 410A*, 507 SAE Flare & Extended ODF Solder Connections *Type Q, EQ, and SQ are not approved for R-410A applications. TYPE QE TYPE BQE FITTING SIZE 1/4 SAE, 90° Angle 3/8 SAE, 90° Angle 3/8 SAE 1/2 SAE 1/4 SAE Inlet Strainer P/N 3008-000 2.43 3/8 SAE Inlet Strainer P/N 1538-000 1.94 QE & BQE DIMENSIONS CONNECTIONS - Inches 1.94 3.93 Top View 2.02 A B C 1.19 – 1.44 1.35 – 1.08 – 1.61 – – 1.80 – 1/4 SAE Inlet Strainer P/N 3008-000 2.53 3/8 SAE Inlet Strainer P/N 1538-000 3.93 60° C A 1.54 B TYPE EQE 2.02 C A B TYPE EBQE 1.94 1.94 C C C C 3.93 3.93 3/8 ODF Insert Strainer P/N 877-003 1/2 ODF Insert Strainer P/N 877-004 2.43 2.53 2.02 A 3/8 ODF Insert Strainer P/N 877-003 1/2 ODF Insert Strainer P/N 877-004 B 2.02 A EQE & EBQE DIMENSIONS CONNECTIONS - Inches A FITTING SIZE B Top View 60° C 2.50 – 0.31 2.42 2.48 0.40 – 2.48 0.50 – 2.39 0.78 3/8 1/2 5/8 7/8 TYPE SQE B 1.87 TYPE SBQE 1.94 1.94 Removable Strainer P/N 3427-000 Top View Removable Strainer P/N 3427-000 60° .40 .40 1.87 3.93 2.43 3.93 2.53 2.02 .31 .84 .74 1.39 2.02 .31 2.48 1.39 BULB SIZES - Inches STANDARD CHARGES 22 134a REFRIGERANT 404A 410A 507 C 0.50 OD x 3.00 – 0.50 OD x 3.00 Z & ZP Series 0.50 OD x 3.00 – 0.50 OD x 3.00 – 0.50 OD x 3.00 CP Series 0.50 OD x 3.00 – GA 0.75 OD x 2.00 – – 0.75 OD x 2.00 – 2.48 Page 22 — BULLETIN 10-10 t TYPE G For Refrigerants 22, 134a, 404A, 507 SAE Flare Connections Sporlan Type G valve is a forged brass body, externally adjustable valve with SAE flare connections. The thermostatic element is replaceable, and the inlet connection has a removable 100 mesh strainer. This valve is designed for small refrigeration systems such as refrigerated cases, coolers and freezers. In addition to refrigeration applications, the externally equalized Type G valve may be used for small capacity air conditioning and heat pump units. Outlet Connections 1/2” SAE Mating Distributors (See Bulletin 20-10) 1603, 1605, 1606, 1608, 1650(R) For complete details of construction, see page 35. Type G 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 507 (P) 402A (L) GVE-1/5 GVE-1/3 GVE-1/2 GVE-3/4 GVE-1 GVE-1-1/2 GVE-2 – GVE-3 GJE-1/8 GJE-1/6 GJE-1/4 GJE-1/2 GJE-1 GJE-1-1/2 GJE-2 GSE-1/8 GSE-1/6 GSE-1/4 GSE-1/2 GSE-1 GSE-1-1/2 GSE-2 GPE-1/8 GPE-1/6 GPE-1/4 GPE-1/2 GPE-1 GPE-1-1/2 GPE-2 1/5 1/3 1/2 3/4 1 1-1/2 2 2-1/2 3 1/8 1/6 1/4 1/2 1 1-1/2 2 1/8 1/6 1/4 1/2 1 1-1/2 2 1/8 1/6 1/4 1/2 1 1-1/2 2 STANDARD TUBING LENGTH GV-1/5 GV-1/3 GV-1/2 GV-3/4 GV-1 GV-1-1/2 – GV-2-1/2 – GJ-1/8 GJ-1/6 GJ-1/4 GJ-1/2 GJ-1 GJ-1-1/2 – GS-1/8 GS-1/6 GS-1/4 GS-1/2 GS-1 GS-1-1/2 – GP-1/8 GP-1/6 GP-1/4 GP-1/2 GP-1 GP-1-1/2 – Blue figures are standard and will be furnished unless otherwise specified. INLET DIMENSIONS 3 lbs. 1.36 kg 1/4 or 3/8 W 3/8 W 1/4 or 3/8 W 1/4 or 3/8 W 5 ft. 1.5 m 1/2 3/8 W 1/4 or 3/8 W 1/4 or 3/8 W 3/8 W 1/4 or 3/8 W 1/4 or 3/8 W 3/8 W 2.31 .25 Removable Strainer P/N 1538-000 1.25 Top View 1.56 with external equalizer 1.68 1.44 BULB SIZES - Inches REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.50 OD x 3.50 Z & ZP Series 0.50 OD x 3.50 – 0.50 OD x 3.50 X 0.75 OD x 4.00 – 0.75 OD x 4.00 CP Series 0.50 OD x 3.50 – VGA 0.75 OD x 2.00 – – – 2 lbs. 0.90 kg OUTLET 1/4 or 3/8 W QValves listed in this column NOT AVAILABLE with MOP Type air conditioning charges. WThe 3/8” SAE inlet fitting has a long taper on the flare surface. A 3/8” x 1/4” reducing flare nut will allow 1/4” OD tubing to be attached to this fitting. 1/4” SAE External Equalizer Connection SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) External Equalizer 1/4” SAE Flare CONNECTIONS - Inches SAE Flare NET WEIGHT 22 (V) Internal Equalizer Q Refer to Recommended Thermostatic Charges on page 3 REFRIGERANT (Sporlan Code) NOMINAL CAPACITY Tons of Refrigeration VALVE TYPE THERMOSTATIC CHARGES AVAILABLE SPECIFICATIONS ELEMENT SIZE NO. 53, KNIFE EDGE JOINT 0.56 Diameter 3.06 of Type X Charge Diaphragm Case is 3.62 1/4 SAE Inlet Strainer P/N 772-000 1.31 1.88 BULLETIN 10-10 — Page 23 t TYPE EG For Refrigerants 22, 134a, 404A, 507 ODF Solder Connections Sporlan Type EG valve is a forged brass body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a removable 100 mesh strainer which can be cleaned and/or replaced without removing the valve from the line. This valve is designed for small refrigeration systems such as refrigerated cases, coolers and freezers. In addition to refrigeration applications, the externally equalized Type EG valve may be used for small capacity air conditioning and heat pump units. Outlet Connections 1/2” ODF Mating Distributors (See Bulletin 20-10) D260, D262 Type EG For complete details of construction, see page 35. THERMOSTATIC CHARGES AVAILABLE STANDARD TUBING LENGTH EGV-1/5 EGV-1/3 EGV-1/2 EGV-3/4 EGV-1 EGV-1-1/2 – EGV-2-1/2 – EGJ-1/8 EGJ-1/6 EGJ-1/4 EGJ-1/2 EGJ-1 EGJ-1-1/2 – EGS-1/8 EGS-1/6 EGS-1/4 EGS-1/2 EGS-1 EGS-1-1/2 – EGP-1/8 EGP-1/6 EGP-1/4 EGP-1/2 EGP-1 EGP-1-1/2 – EGVE-1/5 EGVE-1/3 EGVE-1/2 EGVE-3/4 EGVE-1 EGVE-1-1/2 EGVE-2 – EGVE-3 EGJE-1/8 EGJE-1/6 EGJE-1/4 EGJE-1/2 EGJE-1 EGJE-1-1/2 EGJE-2 EGSE-1/8 EGSE-1/6 EGSE-1/4 EGSE-1/2 EGSE-1 EGSE-1-1/2 EGSE-2 EGPE-1/8 EGPE-1/6 EGPE-1/4 EGPE-1/2 EGPE-1 EGPE-1-1/2 EGPE-2 1/5 1/3 1/2 3/4 1 1-1/2 2 2-1/2 3 1/8 1/6 1/4 1/2 1 1-1/2 2 1/8 1/6 1/4 1/2 1 1-1/2 2 1/8 1/6 1/4 1/2 1 1-1/2 2 Refer to Recommended Thermostatic Charges on page 3 REFRIGERANT (Sporlan Code) 22 (V) 407C (N) 407A (V) 422D (V) 134a (J) 12 (F) 401A (X) 409A (F) 5 ft. 1.5 m 404A (S) 502 (R) 408A (R) 507 (P) 402A (L) CONNECTIONS - Inches W ODF Solder Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 3/8 1/2 QValves listed in this column NOT AVAILABLE with MOP Type air conditioning charges. WODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. 1/4” ODF External Equalizer Connection DIMENSIONS .25 1.33 Top View BULB SIZES - Inches REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.50 OD x 3.50 Z & ZP Series 0.50 OD x 3.50 – 0.50 OD x 3.50 X 0.75 OD x 4.00 – 0.75 OD x 4.00 CP Series 0.50 OD x 3.50 – VGA 0.75 OD x 2.00 – – – SHIPPING WEIGHT External Equalizer 1/4” ODF Solder VALVE TYPE NET WEIGHT Internal Equalizer Q NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 53, KNIFE EDGE JOINT 2 lbs. 0.90 kg 3 lbs. 1.36 kg 2.31 *Removable Strainer P/N 3427-000 1.68 1.80 Diameter 3.06 of Type X Charge Diaphragm Case is 3.62 1.31 2.30 * Type EG valves manufactured prior to June 1994 use a smaller inlet strainer, P/N 1935-000, which has a 1/2” brass hex head. Current Type EG valves use inlet strainer P/N 3427-000 which has a 5/8” brass hex head. These strainers are not interchangeable. The 3427-000 is available as a replacement part. The 1935-000 is no longer available. Page 24 — BULLETIN 10-10 t TYPE BF For Refrigerants 22, 134a, 404A, 507 SAE Flare Connections Sporlan Type BF valve is a small brass bar body valve with SAE flare connections and balanced port construction. This valve has the same exterior dimensions as the Type F valve. The thermostatic element is replaceable, and the inlet connection has a removable 100 mesh strainer. The balanced port construction makes this valve ideally suited for small capacity refrigeration applications which operate over widely varying operating conditions. Outlet Connections 1/2” SAE Mating Distributors (See Bulletin 20-10) 1603, 1605, 1606, 1608, 1650(R) For complete details of construction, see page 35. Type BF 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 507 (P) 402A (L) BFV-AAA BFVE-AAA BFV-AA BFVE-AA AAA 1/8 thru 1/3 AA 1/2 thru 2/3 BFV-A BFV-B BFVE-A A 3/4 thru 1-1/2 BFVE-B B 1-3/4 thru 3 BFV-C BFVE-C C 3-1/4 thru 5-1/2 AAA 1/8 thru 1/5 AA 1/4 thru 1/3 BFJ-AAA BFJE-AAA BFJ-AA BFJE-AA BFJ-A BFJE-A A 1/2 thru 1 BFJ-B BFJE-B B 1-1/4 thru 1-3/4 BFJ-C BFJE-C C 2 thru 3 AAA 1/8 thru 1/5 AA 1/4 thru 1/3 BFS-AAA BFSE-AAA BFS-AA BFSE-AA BFS-A BFSE-A A 1/2 thru 1 BFS-B BFSE-B B 1-1/4 thru 2 BFS-C BFSE-C C 2-1/4 thru 3 AAA 1/8 thru 1/5 AA 1/4 thru 1/3 BFP-AAA BFPE-AAA BFP-AA BFPE-AA BFP-A BFPE-A A 1/2 thru 1 BFP-B BFPE-B B 1-1/4 thru 2 BFP-C BFPE-C C 2-1/4 thru 3 Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET EXTERNAL EQUALIZER 3/8 or 1/2 1/4 SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) External Equalizer Internal Equalizer PORT SIZE CONNECTIONS - Inches SAE Flare NET WEIGHT 22 (V) SAE Flare STANDARD TUBING LENGTH REFRIGERANT (Sporlan Code) THERMOSTATIC CHARGES AVAILABLE VALVE TYPE NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 43, KNIFE EDGE JOINT 1 lb. 454 g 1-1/2 lbs. 680 g 1/4 or 3/8 Elbow Q C Z ZP40 1/4 or 3/8 Elbow Q 3/8 Elbow 1/4 or 3/8 Elbow Q C 1/4 or 3/8 Elbow Q 30 in. 760 mm C Z ZP 3/8 Elbow 1/4 or 3/8 Elbow Q 1/4 or 3/8 Elbow Q 3/8 Elbow 1/4 or 3/8 Elbow Q C Z ZP 1/4 or 3/8 Elbow Q 3/8 Elbow QThe 3/8” SAE inlet fitting has a long taper on the flare surface. A 3/8” x 1/4” reducing flare nut will allow 1/4” OD tubing to be attached to this fitting. DIMENSIONS 1/4” SAE External Equalizer Connection CONNECTIONS - Inches FITTING SIZE SAE Flare 1/4 Elbow 3/8 Elbow 3/8 SAE 1/2 SAE A B C 1.19 1.35 – – – – 1.61 1.80 1.34 0.98 – – 1.94 60° 1.54 Top View 3.76 1/4 SAE Removable Strainer P/N 3008-000 3/8 SAE Removable Strainer P/N 1538-000 BULB SIZES - Inches STANDARD CHARGES 22 C Z & ZP Series 0.50 OD x 3.00 REFRIGERANT 134a 404A 507 0.50 OD x 3.00 – 0.50 OD x 3.00 C A B 2.02 BULLETIN 10-10 — Page 25 t TYPE SBF & EBF For Refrigerants 22, 134a, 404A, 507 Extended Solder Connections Sporlan Types SBF & EBF are small brass bar body valves with Extended ODF solder connections and the same balanced port construction as the Type BF valve. Both valves have replaceable thermostatic elements. The Type EBF has a 100 mesh insert strainer. The Type SBF has a 100 mesh removable strainer that can be cleaned and/ or replaced while the valve is still soldered to the system tubing. The balanced port construction makes these valves ideally suited for small capacity refrigeration applications which operate over widely varying conditions. Outlet Connections 1/2” ODF, 5/8” ODF Type SBF Mating Distributors (See Bulletin 20-10) D260, D262, 1620, 1622, 1651(R) Type EBF For complete details of construction, see page 35. Extended ODF Solder REFRIGERANT with replaceable strainer PORT (Sporlan Code) SIZE Internal External Internal External Equalizer Equalizer Equalizer Equalizer 22 (V) 407C (N) 407A (V) 422D (V) 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 507 (P) 402A (L) SBFV-AAA SBFVE-AAA EBFV-AAA EBFVE-AAA AAA 1/8 thru 1/3 SBFV-AA SBFVE-AA EBFV-AA EBFVE-AA AA 1/2 thru 2/3 SBFV-A SBFVE-A EBFV-A EBFVE-A A 3/4 thru 1-1/2 SBFV-B SBFVE-B EBFV-B EBFVE-B B 1-3/4 thru 3 SBFV-C SBFVE-C EBFV-C EBFVE-C C 3-1/4 thru 5-1/2 SBFJ-AAA SBFJE-AAA EBFJ-AAA EBFJE-AAA AAA 1/8 thru 1/5 SBFJ-AA SBFJE-AA EBFJ-AA EBFJE-AA AA 1/4 thru 1/3 SBFJ-A SBFJE-A EBFJ-A EBFJE-A A 1/2 thru 1 SBFJ-B SBFJE-B EBFJ-B EBFJE-B B 1-1/4 thru 1-3/4 SBFJ-C SBFJE-C EBFJ-C EBFJE-C C 2 thru 3 SBFS-AAA SBFSE-AAA EBFS-AAA EBFSE-AAA AAA 1/8 thru 1/5 SBFS-AA SBFSE-AA EBFS-AA EBFSE-AA AA 1/4 thru 1/3 SBFS-A SBFSE-A EBFS-A EBFSE-A A 1/2 thur 1 SBFS-B SBFSE-B EBFS-B EBFSE-B B 1-1/4 thru 2 SBFS-C SBFSE-C EBFS-C EBFSE-C C 2-1/4 thru 3 SBFP-AAA SBFPE-AAA EBFP-AAA EBFPE-AAA AAA 1/8 thru 1/5 SBFP-AA SBFPE-AA EBFP-AA EBFPE-AA AA 1/4 thru 1/3 SBFP-A SBFPE-A EBFP-A EBFPE-A A 1/2 thru 1 SBFP-B SBFPE-B EBFP-B EBFPE-B B 1-1/4 thru 2 SBFP-C SBFPE-C EBFP-C EBFPE-C C 2-1/4 thru 3 CONNECTIONS - Inches Q Extended ODF Solder Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET EXTERNAL EQUALIZER NET WEIGHT SHIPPING WEIGHT TYPE EBF THERMOSTATIC CHARGES AVAILABLE STANDARD TUBING LENGTH TYPE SBF Extended ODF Solder NOMINAL CAPACITY RANGE Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 43, KNIFE EDGE JOINT C Z ZP40 C 30 in. 760 mm 3/8 1/2 or 5/8 C Z ZP C Z ZP QODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. 1/4 Pointed Toward 1-1/2 Bottom Cap 1 lb. lbs. or 454 g 680 g Parallel to Outlet Connection Page 26 — BULLETIN 10-10 t TYPE SBF & EBF For Refrigerants 22, 134a, 404A, 507 Extended Solder Connections TYPE SBF 1/4” ODF External Equalizer Connection 2.00 2.33 1.94 30° Removable Strainer P/N 3427-000 A 3.76 Top View .74 DIMENSIONS 1.39 CONNECTIONS - Inches OUTLET FITTING SIZE 1/2 5/8 2.02 .31 2.50 A 0.40 0.50 BULB SIZES - Inches STANDARD CHARGES REFRIGERANT 134a 404A 0.50 OD x 3.00 22 C Z & ZP Series 0.50 OD x 3.00 – 507 0.50 OD x 3.00 TYPE EBF 1/4” ODF External Equalizer Connection 2.00 2.33 1.94 30° .31 3.76 2.43 Top View DIMENSIONS 2.50 CONNECTIONS - Inches OUTLET FITTING SIZE 1/2 5/8 A 0.40 0.50 BULB SIZES - Inches STANDARD CHARGES 22 C Z & ZP Series 0.50 OD x 3.00 3/8” ODF Insert Strainer P/N 877-003 REFRIGERANT 134a 404A 0.50 OD x 3.00 – 507 0.50 OD x 3.00 A 2.50 2.02 BULLETIN 10-10 — Page 27 t TYPE S For Refrigerants 22, 134a, 404A, 507 ODF Solder Connections Sporlan Type S valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve is designed for both air conditioning and refrigeration applications. Outlet Connections 5/8” ODF, 7/8” ODF, 1-1/8” ODF Mating Distributors (See Bulletin 20-10) 1112, 1113, 1115, 1116, 1620, 1622, 1651(R), 1653(R), 1655(R) Type S For complete details of construction, see page 35. 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 507 (P) 402A (L) SVE-2 SVE-3 SVE-4 SVE-5 SVE-8 SVE-10 SJE-2 SJE-2-1/2 SJE-3 SJE-5 SJE-6 SSE-2 SSE-3 SSE-4 SSE-6 SSE-7 SPE-2 SPE-3 SPE-4 SPE-6 SPE-7 2 3 4 5 8 10 2 2-1/2 3 5 6 2 3 4 6 7 2 3 4 6 7 STANDARD TUBING LENGTH SV-2 SV-3 SV-4 SV-5 – – SJ-2 SJ-2-1/2 SJ-3 – – SS-2 SS-3 SS-4 – – SP-2 SP-3 SP-4 – – 5 ft. 1.5 m SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) External Equalizer CONNECTIONS - Inches W ODF Solder NET WEIGHT 22 (V) Internal Equalizer Q THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) Refer to Recommended Thermostatic Charges on page 3 VALVE TYPE NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 83, KNIFE EDGE JOINT 2 lbs. 0.90 kg 3 lbs. 1.36 kg Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 3/8 or 1/2 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 3/8 or 1/2 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 3/8 or 1/2 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 3/8 or 1/2 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 QValves listed in this column NOT AVAILABLE with MOP Type air conditioning charges. WODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing. 2.31 DIMENSIONS 30° CONNECTIONS - Inches FITTING SIZE A B C 3/8 1/2 5/8 7/8 1-1/8 1.34 1.29 1.50 – – – 1.36 1.57 2.13 2.19 0.31 0.40 0.50 0.78 0.91 1.92 BULB SIZES - Inches REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.50 OD x 3.50 Z & ZP Series 0.50 OD x 3.50 – 0.50 OD x 3.50 X 0.75 OD x 4.00 – 0.75 OD x 4.00 CP Series 0.50 OD x 3.50 – VGA 0.75 OD x 2.00 – – – 1/4” ODF External Equalizer Connection 1.66 2.13 C Top View C 3.53 Diameter of Type X Charge Diaphragm Case is 3.62 A B Page 28 — BULLETIN 10-10 t TYPE EBS For Refrigerants 22, 134a, 404A, 507 Extended ODF Solder Connections Sporlan Type EBS valve is a brass bar body valve having the same physical size as the Type S valve except the Type EBS features a balanced port construction and extended ODF connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. The balanced port construction makes this valve ideally suited for refrigeration and air conditioning applications which operate over widely varying conditions. Outlet Connections 7/8” ODF, 1-1/8” ODF, 1-3/8” ODF Mating Distributors (See Bulletin 20-10) 1112, 1113, 1115, 1116, 1117, 1126, 1128, 1653(R), 1655(R), 1657(R) Type EBS For complete details of construction, see page 35. 22 (V) 407C (N) 407A (V) 422D (V) 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 507 (P) INLET EXTERNAL EQUALIZER OUTLET 8 1/2 or 5/8 7/8 or 1-1/8 EBSVE-11 W 11 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 EBSVE-15 15 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 EBSVE-20 20 7/8 1-1/8 or 1-3/8 EBSJE-5 W 5 EBSJE-7 W 7 EBSJE-9 9 EBSJE-12 12 EBSSE-6 W 6 EBSSE-7-1/2 W 7-1/2 EBSSE-10 10 EBSSE-13 13 EBSPE-6 W 6 5 ft. 1.5 m 1/2 or 5/8 7/8 or 1-1/8 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 7/8 1-1/8 or 1-3/8 1/2 or 5/8 7/8 or 1-1/8 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 7/8 1-1/8 or 1-3/8 1/2 or 5/8 7/8 or 1-1/8 7-1/2 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 EBSPE-10 10 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 EBSPE-13 13 7/8 1-1/8 or 1-3/8 1/4 Pointed Toward Bottom Cap or Parallel to Outlet Connection 2 lbs. 3 lbs. 0.90 kg 1.36 kg QODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing. WApproved for bi-directional applications. EMinimum quantities may apply to non-standard connections. Not all connection combinations are available. * X charge not available. 1/4” ODF External Equalizer Connection DIMENSIONS CONNECTIONS - Inches FITTING SIZE 1/2 5/8 7/8 1-1/8 1-3/8 A B C 2.49 2.46 2.46 – – – – 2.53 2.53 3.04 0.40 0.50 0.78 0.91 0.97 30° 2.31 1.81 C C Top View BULB SIZES - Inches REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.50 OD x 3.50 Z & ZP Series 0.50 OD x 3.50 – 0.50 OD x 3.50 CP Series 0.50 OD x 3.50 – VGA 0.75 OD x 2.00 – – – 3.41 2.82 A B SHIPPING WEIGHT Blue figures are standard and will be furnished unless otherwise specified. NET WEIGHT CONNECTIONS - Inches E Q Extended ODF Solder EBSVE-8 W EBSPE-7-1/2 W 402A (L) STANDARD TUBING LENGTH External Equalizer *Refer to Recommended Thermostatic Charges on page 3 REFRIGERANT (Sporlan Code) THERMOSTATIC CHARGES AVAILABLE VALVE TYPE NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 83, KNIFE EDGE JOINT BULLETIN 10-10 — Page 29 t TYPE O For Refrigerants 22, 134a, 404A, 410A, 507 ODF Solder Connections Sporlan Type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve type features a balanced port construction, and it is designed for both air conditioning and refrigeration applications. A synthetic seating surface provides tight shut-off during system off periods. 35 tons R-410A, and a large body which extends capacities to 70 tons R-22 and 60 tons R-410A. Outlet Connections 1-1/8” ODF, 1-3/8” ODF, 1-5/8” ODF Type O Mating Distributors (See Bulletin 20-10) 1115, 1116, 1117, 1125, 1126, 1127, 1128, 1143, 1655(R), 1657(R), 1659(R) For complete details of construction, see page 35. This valve type has two body styles: a small body which provides capacities up to 30 tons R-22 and 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 410A (Z) 507 (P) 402A (L) 15 OVE-20 W 20 OVE-30 W 30 OVE-40 40 OVE-55 55 OVE-70 70 OJE-9 9 OJE-12 12 OJE-16 16 OJE-23 23 OJE-32 32 OJE-40 40 OSE-9 9 OSE-12 12 OSE-21 21 OSE-30 30 OSE-35 35 OSE-45 45 OZE-20 W 20 OZE-25 W 25 OZE-35 W 35 OZE-50 50 OZE-60 60 OPE-9 9 OPE-12 12 OPE-21 21 OPE-30 30 OPE-35 35 OPE-45 45 STANDARD TUBING LENGTH THERMOSTATIC CHARGES AVAILABLE 1-1/8 7/8 83 33 85 85-3 83 33 1-1/8 1-3/8 or 1-5/8 1-1/8 1-3/8 1-1/8 7/8 1-3/8 or 1-5/8 1-1/8 1-3/8 5 feet 1.5 m 1-1/8 1-3/8 or 1-5/8 3 lbs. 1.36 kg 4 lbs. 1.82 kg 5 lbs. 2.27 kg 2 lbs. 0.90 kg 3 lbs. 1.36 kg 4 lbs. 1.82 kg 5 lbs. 2.27 kg 2 lbs. 0.90 kg 3 lbs. 1.36 kg 4 lbs. 1.82 kg 5 lbs. 2.27 kg 7/8 1-1/8 2 lbs. 0.90 kg 3 lbs. 1.36 kg 1-1/8 1-3/8 4 lbs. 1.82 kg 5 lbs. 2.27 kg 2 lbs. 0.90 kg 3 lbs. 1.36 kg 4 lbs. 1.82 kg 5 lbs. 2.27 kg 7/8 1-1/8 1-3/8 1-1/8 1-3/8 or 1-5/8 QODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing. WOptional bi-directional feature is available, please contact Sporlan Division of Parker for more information. * X charge not available. 2 lbs. 0.90 kg OUTLET 1-3/8 33 83 INLET 7/8 83 33 Blue figures are standard and will be furnished unless otherwise specified. SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) OVE-15 W CONNECTIONS - Inches Q ODF Solder NET WEIGHT 22 (V) External Equalizer *Refer to Recommended Thermostatic Charges on page 3 REFRIGERANT (Sporlan Code) THERMOSTATIC ELEMENT SIZE NO. VALVE TYPE NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 83, NO. 33, NO. 85 (R-410A), AND NO. 85-3 (R-410A), KNIFE EDGE JOINT Page 30 — BULLETIN 10-10 t TYPE O For Refrigerants 22, 134a, 404A, 410A, 507 ODF Solder Connections TYPE O with NUMBER 83 and 85 ELEMENT 2.31 1/4” ODF External Equalizer Connection 1.40 1.70 2.43 Top View C DIMENSIONS CONNECTIONS - Inches STRAIGHT THRU ODF SOLDER 7/8 1-1/8 1-3/8 C A B C 2.09 2.21 – 2.08 2.23 2.39 0.78 0.91 0.97 4.14 BULB SIZES - Inches A B REFRIGERANT 404A STANDARD CHARGES 22 134a 410A 507 C 0.50 OD X 3.50 – 0.50 OD X 3.50 Z & ZP Series 0.50 OD X 3.50 – 0.50 OD X 3.50 – 0.50 OD X 3.50 CP Series 0.50 OD X 3.50 – – GA 0.75 OD X 2.00 – – 0.75 OD X 2.00 – TYPE O with NUMBER 33 and 85-3 ELEMENT 1/4” ODF External Equalizer Connection 2.31* 2.75 1.59 1.93 2.90 Top View C C DIMENSIONS CONNECTIONS - Inches STRAIGHT THRU ODF SOLDER 1-1/8 1-3/8 1-5/8 5.52 A B C 2.69 – – – 2.84 3.12 0.91 0.97 1.09 BULB SIZES - Inches REFRIGERANT 22 134a 404A 410A 507 C 0.75 OD x 4.00 0.50 OD x 5.00 0.75 OD x 4.00 – 0.75 OD x 4.00 Z & ZP Series 0.75 OD x 4.00 – 0.75 OD x 4.00 – 0.75 OD x 4.00 CP Series 0.75 OD x 4.00 – – GA 0.75 OD x 4.00 – – 0.75 OD X 2.00 – STANDARD CHARGES A B *R-410A 85-3 Element. BULLETIN 10-10 — Page 31 t TYPE H For Refrigerants 22, 134a, 404A, 507 ODF Solder - Flange Connections Sporlan Type H valve is a brass bar body, externally adjustable valve available with either ODF solder or FPT flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent 16 mesh strainer. The FPT flange connection requires the Sporlan K-1178 adapter kit. This valve type provides the smallest capacity TEVs with flange connections, and it is designed for both air conditioning and refrigeration applications. Outlet Connections 7/8” ODF, 1-1/8” ODF, “H” flange type Mating Distributors (See Bulletin 20-10) 1109, 1110, 1112, 1113, 1115, 1116, 1124, 1192 (aluminum), 1653(R), 1655(R) Type H For complete details of construction, see page 35. 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 507 (P) 402A (L) HVE-5-1/2 HVE-7 HVE-11 HVE-16 HVE-20 HJE-3 HJE-4 HJE-5 HJE-8 HJE-12 HSE-3 HSE-4 HSE-6-1/2 HSE-9 HSE-12 HPE-3 HPE-4 HPE-6-1/2 HPE-9 HPE-12 5-1/2 7 11 16 20 3 4 5 8 12 3 4 6-1/2 9 12 3 4 6-1/2 9 12 STANDARD TUBING LENGTH HV-5-1/2 – – – – HJ-3 HJ-4 HJ-5 – – HS-3 HS-4 – – – HP-3 HP-4 – – – 5 ft. 1.5 m FLANGE RING SIZE OD x ID Inches R SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) External Equalizer W CONNECTIONS - Inches E ODF Solder NET WEIGHT 22 (V) Internal Equalizer Q Refer to Recommended Thermostatic Charges on page 3 REFRIGERANT (Sporlan Code) NOMINAL CAPACITY Tons of Refrigeration VALVE TYPE THERMOSTATIC CHARGES AVAILABLE SPECIFICATIONS ELEMENT SIZE NO. 33, KNIFE EDGE JOINT 1.25 x 1.00 5 lbs. 2.27 kg 6 lbs. 2.72 kg Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 5/8 or 7/8 7/8 or 1-1/8 7/8 7/8 or 1-1/8 5/8 or 7/8 7/8 or 1-1/8 7/8 7/8 or 1-1/8 5/8 or 7/8 7/8 or 1-1/8 7/8 7/8 or 1-1/8 5/8 or 7/8 7/8 or 1-1/8 7/8 7/8 or 1-1/8 QValves listed in this column NOT AVAILABLE with MOP Type air conditioning charges. WStandard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request. EODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 5/8” ODF will receive 5/8” OD tubing. RKit K-1178 with two brass bushings is available for two purposes: 1) To allow the current Type H valve to replace obsolete Types T and H with 1.125” x 0.75” flange rings by mating with the smaller flange ring bushings and/or distributors. 2) To allow the Type H to use 1/2” FPT connections — Part number 225-002 and 1/2” socket weld connections — Part number 580-000. Order the appropriate 1/2” connections and one K-1178 per valve. 2.75 DIMENSIONS CONNECTIONS - Inches SOLDERING BUSHING 1/2 5/8 7/8 1-1/8 A B 2.00 2.00 2.00 2.06 0.88 0.88 0.88 0.94 2.06 B B BULB SIZES - Inches STANDARD CHARGES C Z & ZP Series X CP Series VGA REFRIGERANT 22 134a 404A 507 0.75 OD x 4.00 0.50 OD x 5.00 0.75 OD x 4.00 0.75 OD x 4.00 – 0.75 OD x 4.00 0.75 OD x 4.00 – 0.75 OD x 4.00 0.75 OD x 4.00 – 0.75 OD x 4.00 – – – 4.50 A A Diameter of Type X Charge Diaphragm Case is 3.62 Page 32 — BULLETIN 10-10 t TYPE M For Refrigerants 22, 134a, 404A, 507 ODF Solder - Flange Connections Sporlan Type M valve is a cast bronze body, externally adjustable valve with either ODF solder or FPT flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve type provides capacities greater than the Type H, and it is designed for both air conditioning and refrigeration applications. Flanges for the Type M valve are interchangeable with the Type V. Outlet Connections 1-1/8” ODF, 1-3/8” ODF, 1-5/8“ ODF, M/V flange Mating Distributors (See Bulletin 20-10) 1115, 1116, 1117, 1119, 1121, 1125, 1126, 1127, 1128, 1143, 1193 (aluminum), 1655(R), 1657(R), 1659(R) Type M For complete details of construction, see page 35. 134a (J) 12 (F) 401A (X) 409A (F) 404A (S) 502 (R) 408A (R) 507 (P) 402A (L) INLET OUTLET FLANGE RING SIZE OD x ID Inches SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) W CONNECTIONS - Inches E ODF Solder Flange NET WEIGHT MVE-21 22 (V) Blue figures are standard and will be furnished unless otherwise specified. STANDARD TUBING LENGTH External Equalizer Q THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) 1.75 x 1.25 8 lbs. 3.63 kg 9 lbs. 4.09 kg 21 MVE-26 26 MVE-34 34 MVE-42 42 MJE-15 15 MJE-20 20 MJE-25 25 MSE-15 15 MSE-20 20 MSE-25 25 MSE-30 30 MPE-15 15 MPE-20 20 MPE-25 25 MPE-30 30 7/8 or 1-1/8 Refer to Recommended Thermostatic Charges on page 3 VALVE TYPE NOMINAL CAPACITY Tons of Refrigeration SPECIFICATIONS ELEMENT SIZE NO. 63, GASKET JOINT 7/8 or 1-1/8 5 ft. 1.5 m 10 ft. 3m 7/8 or 1-1/8 1-1/8 1-3/8 or 1-5/8 7/8 or 1-1/8 7/8 or 1-1/8 7/8 or 1-1/8 7/8 or 1-1/8 7/8 or 1-1/8 QStandard External Equalizer Connection 1/4” SAE Flare. 1/4” ODF Solder connection available on request. WFPT connections also available on request; 1/2” FPT - Part Number 360-000, 3/4” FPT - Part Number 360-001, 1” FPT - Part Number 362-000. EODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 7/8” ODF will receive 7/8” OD tubing. 3.62 DIMENSIONS 2.81 CONNECTIONS - Inches SOLDERING BUSHING 7/8 1-1/8 1-3/8 1-5/8 A B 2.38 2.75 2.75 3.22 0.88 0.94 0.94 1.22 BULB SIZES - Inches REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.88 OD x 6.00 Z & ZP Series 0.88 OD x 6.00 – 0.88 OD x 6.00 X 0.88 OD x 6.00 – 0.88 OD x 6.00 CP Series 0.75 OD x 4.00 – VGA 0.75 OD x 4.00 – – – B B 4.94 Diameter of Type X Charge Diaphragm Case is 4.75 A A BULLETIN 10-10 — Page 33 t TYPE V For Refrigerants 22, 134a, 404A, 507 ODF Solder - Flange Connections Sporlan Type V valve is a cast bronze body, externally adjustable valve available with either ODF solder or FPT flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve features a dual port semi-balanced design, and it is designed for both air conditioning and refrigeration applications. A synthetic seating surface provides tight shut-off during system off periods. This valve provides greater capacities than the Type M. Flanges for the Type V valve are interchangeable with the Type M. Outlet Connections 1-3/8” ODF, 1-5/8“ ODF, M/V flange Mating Distributors (See Bulletin 20-10) 1117, 1119, 1121, 1125, 1126, 1127, 1128, 1143, 1193 (aluminum), 1657(R), 1659(R) Type V For complete details of construction, see page 35. VVE-70 70 VVE-100 100 134a (J) VJE-35 35 12 (F) 401A (X) 409A (F) VJE-45 45 VJE-55 55 404A (S) VSE-38 38 VSE-50 50 VSE-70 70 VPE-38 38 VPE-50 50 VPE-70 70 502 (R) 408A (R) 507 (P) 402A (L) 5 ft. 1.5 m 10 ft. 3m INLET OUTLET 1-1/8 or 1-3/8 1-1/8 1-3/8 or 1-5/8 FLANGE RING SIZE OD x ID Inches SHIPPING WEIGHT 407C (N) 407A (V) 422D (V) W CONNECTIONS - Inches E ODF Solder Flange NET WEIGHT 52 22 (V) Blue figures are standard and will be furnished unless otherwise specified. STANDARD TUBING LENGTH VVE-52 REFRIGERANT (Sporlan Code) Refer to Recommended Thermostatic Charges on page 3 External Equalizer Q NOMINAL CAPACITY Tons of Refrigeration VALVE TYPE THERMOSTATIC CHARGES AVAILABLE SPECIFICATIONS ELEMENT SIZE NO. 63, GASKET JOINT 1.75 x 1.25 9 lbs. 4.09 kg 10 lbs. 4.54 kg QStandard External Equalizer Connection 1/4” SAE Flare. 1/4” ODF Solder connection available on request. WFPT connections also available on request; 1/2” FPT - Part Number 360-000, 3/4” FPT - Part Number 360-001, 1” FPT - Part Number 362-000. EODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 7/8” ODF will receive 7/8” OD tubing. 3.62 DIMENSIONS CONNECTIONS - Inches SOLDERING BUSHING 7/8 1-1/8 1-3/8 1-5/8 A B 2.38 2.75 2.75 3.22 0.88 0.94 0.94 1.22 4.19 B B BULB SIZES - Inches REFRIGERANT STANDARD CHARGES 22 134a 404A 507 C 0.88 OD x 6.00 Z & ZP Series 0.88 OD x 6.00 – 0.88 OD x 6.00 X 0.88 OD x 6.00 – 0.88 OD x 6.00 CP Series 0.75 OD x 4.00 – VGA 0.75 OD x 4.00 – – – 4.81 A A Diameter of Type X Charge Diaphragm Case is 4.75 Page 34 — BULLETIN 10-10 t TYPE W For Refrigerants 22, 134a ODF Solder - Flange Connections Sporlan Type W valve is a cast bronze body, externally adjustable valve available with ODF solder flange connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve features a dual port semi-balanced design, and it is designed primarily for large capacity chillers. A synthetic seating surface provides tight shut-off during system off periods. This valve provides the largest capacities available for flange connection TEVs. Outlet Connections 1-3/8” ODF, 1-5/8“ ODF Mating Distributors (See Bulletin 20-10) 1117, 1125, 1126, 1127, 1128, 1143, 1657(R), 1659(R) For complete details of construction, see page 35. Type W 407C (N) 407A (V) 422D (V) 134a (J) 12 (F) 401A (X) 409A (F) 135 E 63 WVE-180 180 G only 7 WJE-80 80 E 63 WJE-110 110 G only 7 FLANGE RING SIZE OD x ID Inches CONNECTIONS - Inches W ODF Solder Flange 10 ft. 3m INLET OUTLET 1-1/8 1-3/8 1-5/8 or 2-1/8 1-1/8 1-3/8 1-5/8 or 2-1/8 R 2.75 x 2.19 10 lbs. 11 lbs. 4.54 kg 4.99 kg QStandard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request. WODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus, 1-1/8” ODF will receive 1-1/8” OD tubing. ERefer to Recommended Thermostatic Charges, page 3. RFor 1-1/2” NPT connections, order flanges separately for MA42 solenoid eg P/N 933-1. The customer must supply 5/8” diameter x 6” long bolts and 5/8” diameter nuts. 3.38 B A * D 2.50 E 0.75 0.53 - Diameter Bolt Holes 4.56 C 2.06 2.78 0.12 D A B DIMENSIONS CONNECTIONS - Inches FITTING SIZE 1-1/8 1-3/8 1-5/8 2-1/8 A B C D E F 1.12 1.38 1.62 2.12 1.27 1.53 1.78 2.44 1.06 1.28 1.50 1.94 0.91 0.97 1.09 1.34 1.56 1.62 1.75 1.53 3.09 3.16 3.28 3.25 STANDARD CHARGES C Z & ZP Series X CP Series VGA G 6.12 F BULB SIZES - Inches ELEMENT SIZE NUMBER 63 7 REFRIGERANT 134a 0.88 OD x 6.00 0.88 OD x 6.00 – 0.88 OD x 6.00 – 0.75 OD x 4.00 0.75 OD x 4.00 – 0.75 OD x 4.00 – 22 SHIPPING WEIGHT WVE-135 Blue figures are standard and will be furnished unless otherwise specified. STANDARD TUBING LENGTH ELEMENT SIZE NUMBER 22 (V) External Equalizer Q THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) NOMINAL CAPACITY Tons of Refrigeration VALVE TYPE NET WEIGHT SPECIFICATIONS ELEMENT SIZE NO. 63 and 7, GASKET JOINT F *Diameter of Diaphragm Case is 3.62 for Small W and 4.75 for Large W BULLETIN 10-10 — Page 35 t MATERIALS & DETAILS OF CONSTRUCTION VALVE TYPE BODY SEAT PIN PIN CARRIER PUSHROD(S) TYPE OF JOINTS CONNECTIONS INLET STRAINER RC Machined Brass Bar Brass Port Machined in Body Stainless Steel – Stainless Steel Knife Edge to Metal Chatleff, SAE Flare, ODF Copper Fittings Silver Soldered to Body No Strainer ER Machined Brass Bar Brass Port Machined in Body Stainless Steel – Stainless Steel Knife Edge to Metal ODF Copper Fittings Silver Soldered to Body No Strainer F Machined Brass Bar Brass Stainless Steel Brass Stainless Steel Knife Edge to Metal SAE Flare Fittings Silver Soldered to Body Removable Strainer Screen EF Machined Brass Bar Brass Stainless Steel Brass Stainless Steel Knife Edge to Metal ODF Copper Fittings Silver Soldered to Body Insert Strainer Machined Brass Bar Brass Stainless Steel Brass Stainless Steel Knife Edge to Metal SAE Flare Fittings Silver Soldered to Body Machined Brass Bar Brass Stainless Steel Brass Stainless Steel Knife Edge to Metal ODF Copper Fittings Silver Soldered to Body Machined Brass Bar Brass Stainless Steel Brass Stainless Steel Knife Edge to Metal Extended Copper Fittings Silver Soldered to Body G Brass Forging Brass Stainless Steel Brass Knife Edge to Metal SAE Flare, Integral Part of Brass Forged Body EG Brass Forging Brass Stainless Steel Brass Internally Equalized: Triangular Stainless Steel ODF Copper Fittings Silver Soldered to Body S Machined Brass Bar Brass Stainless Steel Brass Externally Equalized: Round Stainless Steel Knife Edge to Metal Knife Edge to Metal ODF Copper Fittings Silver Soldered to Body BF Machined Brass Bar Brass Stainless Steel – Stainless Steel Knife Edge to Metal SAE Flare Fittings Silver Soldered to Body SBF Machined Brass Bar Brass Stainless Steel – Stainless Steel Knife Edge to Metal ODF Copper Fittings Silver Soldered to Body EBF Machined Brass Bar Brass Stainless Steel – Stainless Steel Knife Edge to Metal Extended Copper Fittings Silver Soldered to Body Insert Strainer EBS Machined Brass Bar Brass Port Machined in Body Stainless Steel – Stainless Steel Knife Edge to Metal ODF Copper Fittings Silver Soldered to Body Coarse Mesh Strainer Disc SMALL Machined Brass Bar Brass Port Machined in Body – Stainless Steel Knife Edge to Metal ODF Copper Fittings Silver Soldered to Body Coarse Mesh Strainer Disc LARGE O Machined Brass Bar Brass Port Machined in Body – Stainless Steel ODF Copper Fittings Silver Soldered to Body Coarse Mesh Strainer Disc H Machined Brass Bar Stainless Steel or Brass Stainless Steel Brass Stainless Steel Knife Edge At Element and Bottom Cap Gasket At Seal Cap Solder-Flange, Pipe Flange Coarse Mesh Strainer Disc M Bronze Casting Stainless Steel or Brass Stainless Steel Brass Stainless Steel Gasket Solder-Flange, Pipe Flange Coarse Mesh Strainer Disc V Bronze Casting Stainless Steel Gasket Solder-Flange, Pipe Flange Coarse Mesh Strainer Disc Bronze Casting Bronze Piston With Synthetic Sealing Surface – W Dual Port, Seats Machined in Valve Body – Stainless Steel Gasket Solder-Flange, Pipe Flange Coarse Mesh Strainer Disc Q/ BQ SQ/ SBQ EQ/ EBQ O Brass Piston With Synthetic Seating Surface Removable Strainer Screen Insert Strainer Removable Strainer Screen Coarse Mesh Strainer Disc Removable Strainer Screen NOTE: Materials and Construction specifications listed on this page may change without notice. Contact Sporlan Division of Parker for current specifications on materials and other details of construction. Page 36 — BULLETIN 10-10 t OEM TYPE THERMOSTATIC EXPANSION VALVES In addition to the standard line of Thermostatic Expansion Valves listed in this bulletin, special valve types are also available to fill manufacturers’ specific requirements. Listed below are examples of valves that are supplied for quantity orders. VALVE TYPE CONNECTION TYPE VALVE DESCRIPTION and APPLICATION TYPICAL REPLACEMENT TEVs SAE Flare or ODF Solder Small brass body valve available with either angle style or straight through connections. Type BI valves with straight through connections are normally supplied non-adjustable. The Type BBI is a Type BI valve modified to incorporate balanced port construction. The thermostatic element is not replaceable on valves manufactured prior to 1994. Current models use a replaceable No. 43 element. Typical applications: small capacity R-22 air conditioning and heat pump systems. ER, RC, G, EG, S, Q, SQ, EQ, BQ, SBQ, EBQ BI*/BBI * BI is OBSOLETE. Y997-BI SAE Flare or ODF Solder Type BI valve modified to incorporate an internal check valve and bypass tube to allow for reverse flow with heat pump applications. The valve is not adjustable. The thermostatic element is not replaceable on valves manufactured prior to 1994. Current models use a replaceable No. 43 element. Typical applications: small capacity R-22 heat pump systems. SAE Flare or ODF Solder Small brass body valve available with either angle style or straight through connections. Type I valves with straight through connections are normally supplied non-adjustable. Current models use a replaceable No. 43 element. This valve is available with the Rapid Pressure Balancer (RPB) feature for off-cycle pressure equalization. Typical applications: small capacity R-22 air conditioning and heat pump systems. I CBI*/CBBI RC, G, EG, S, Q, SQ, EQ, BQ, SBQ, EBQ Note: A check valve may be required for install around the TEV to allow flow in the reverse direction. ER, RC, G, EG, S, Q, SQ, EQ, BQ, SBQ, EBQ RC, G, EG, S, Q, SQ, EQ, BQ, SBQ, EBQ SAE Flare or ODF Solder Type BI/BBI valves modified to incorporate an internal check valve to allow for reverse flow with heat pump applications. Type CBI/CBBI valves with straight through connections are normally supplied non-adjustable. The valve uses a replaceable No. 43 element. Typical applications: small capacity R-22 heat pump systems. SAE Flare or ODF Solder Small brass body valve available only with straight through connections and external adjustment. The thermostatic element is not replaceable on valves manufactured prior to 1994. Current models use a replaceable No. 43 element. Typical applications: small capacity air conditioning and refrigeration applications where an external adjustment is desired. ER, RC, G, EG, S, Q, SQ, EQ, BQ, SBQ, EBQ SAE Flare or ODF Solder Brass body valve available with either angle style or straight through connections. Angle style valve is available only with SAE flare connections. Type X valves with straight through connections are normally supplied non-adjustable. The thermostatic element is a replaceable type, size number 53. This valve is available with the Rapid Pressure Balancer (RPB) feature in certain nominal capacities for off-cycle pressure equalization. Typical applications: R-22 air conditioning and heat pump systems. ER, RC, G, EG, S, Q, SQ, EQ, BQ, SBQ, EBQ * CBI is OBSOLETE. Note: A check valve may be required for install around the TEV to allow flow in the reverse direction. FB X FEATURES NOT INCLUDED IN THIS BULLETIN Special features such as non-adjustable construction or similar modifications are also available for both standard and special valves when ordered in reasonable quantities. Automatic (constant pressure) expansion valves are also available on special order. If you have a special valve application, contact your Sporlan Sales Engineer or Sporlan Division, Parker Hannifin, 206 Lange Drive, Washington, Missouri 63090, 636-239-1111. BULLETIN 10-10 — Page 37 OFFER OF SALE The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors (“Seller”) are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions. Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be referred to as “Products”. 1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for Products, to or from Buyer is expressly conditioned on Buyer’s assent to these Terms and Conditions and to the terms and conditions found on-line at www.parker.com/ saleterms/. Seller objects to any contrary or additional term or condition of Buyer’s order or any other document issued by Buyer. 2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages of this document are valid for 30 days. After 30 days, Seller may change prices to reflect any increase in its costs resulting from state, federal or local legislation, price increases from its suppliers, or any change in the rate, charge, or classification of any carrier. The prices stated on the reverse or preceding pages of this document do not include any sales, use, or other taxes unless so stated specifically. Unless otherwise specified by Seller, all prices are F.O.B. Seller’s facility, and payment is due 30 days from the date of invoice. After 30 days, Buyer shall pay interest on any unpaid invoices at the rate of 1.5% per month or the maximum allowable rate under applicable law. 3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and Seller shall not be responsible for any damages resulting from any delay. Regardless of the manner of shipment, title to any products and risk of loss or damage shall pass to Buyer upon tender to the carrier at Seller’s facility (i.e., when it’s on the truck, it’s yours). Unless otherwise stated, Seller may exercise its judgment in choosing the carrier and means of delivery. No deferment of shipment at Buyers’ request beyond the respective dates indicated will be made except on terms that will indemnify, defend and hold Seller harmless against all loss and additional expense. Buyer shall be responsible for any additional shipping charges incurred by Seller due to Buyer’s changes in shipping, product specifications or in accordance with Section 13, herein. 4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects in material or workmanship for a period of twelve months from the date of delivery to Buyer or 2,000 hours of normal use, whichever occurs first. This warranty is made only to Buyer and does not extend to anyone to whom Products are sold after purchased from Seller. The prices charged for Seller’s products are based upon the exclusive limited warranty stated above, and upon the following disclaimer: DISCLAIMER OF WARRANTY: THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRANTIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon delivery. No claims for shortages will be allowed unless reported to the Seller within 10 days of delivery. No other claims against Seller will be allowed unless asserted in writing within 60 days after delivery or, in the case of an alleged breach of warranty, within 30 days after the date within the warranty period on which the defect is or should have been discovered by Buyer. Any action based upon breach of this agreement or upon any other claim arising out of this sale (other than an action by Seller for any amount due to Seller from Buyer) must be commenced within thirteen months from the date of tender of delivery by Seller or, for a cause of action based upon an alleged breach of warranty, within thirteen months from the date within the warranty period on which the defect is or should have been discovered by Buyer. 6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS. 7. Contingencies. Seller shall not be liable for any default or delay in performance if caused by circumstances beyond the reasonable control of Seller. 8. User Responsibility. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and Product and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application and follow applicable industry standards and Product information. If Seller provides Product or system options, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the Products or systems. 9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confidential information or equipment furnished by Buyer or any other items which become Buyer’s property, may be considered obsolete and may be destroyed by Seller after two consecutive years have elapsed without Buyer placing an order for the items which are manufactured using such property. Seller shall not be responsible for any loss or damage to such property while it is in Seller’s possession or control. 10. Special Tooling. A tooling charge may be imposed for any special tooling, including without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. Such special tooling shall be and remain Seller’s property notwithstanding payment of any charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to Seller which is utilized in the manufacture of the Products, even if such apparatus has been specially converted or adapted for such manufacture and notwithstanding any charges paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or otherwise dispose of any special tooling or other property in its sole discretion at any time. 11. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise, Seller shall retain a security interest in the goods delivered and this agreement shall be deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems necessary to perfect its security interest. Seller shall have a security interest in, and lien upon, any property of Buyer in Seller’s possession as security for the payment of any amounts owed to Seller by Buyer. 12. Improper use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for personal injury, property damage, patent, trademark or copyright infringement or any other claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out of: (a) improper selection, improper application or other misuse of Products purchased by Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product; or (d) Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify Buyer under any circumstance except as otherwise provided. 13. Cancellations and Changes. Orders shall not be subject to cancellation or change by Buyer for any reason, except with Seller’s written consent and upon terms that will indemnify, defend and hold Seller harmless against all direct, incidental and consequential loss or damage. Seller may change product features, specifications, designs and availability with notice to Buyer. 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this agreement without the prior written consent of Seller. 15. Entire Agreement. This agreement contains the entire agreement between the Buyer and Seller and constitutes the final, complete and exclusive expression of the terms of the agreement. All prior or contemporaneous written or oral agreements or negotiations with respect to the subject matter are herein merged. 16. Waiver and Severability. Failure to enforce any provision of this agreement will not waive that provision nor will any such failure prejudice Seller’s right to enforce that provision in the future. Invalidation of any provision of this agreement by legislation or other rule of law shall not invalidate any other provision herein. The remaining provisions of this agreement will remain in full force and effect. 17. Termination. This agreement may be terminated by Seller for any reason and at any time by giving Buyer thirty (30) days written notice of termination. In addition, Seller may by written notice immediately terminate this agreement for the following: (a) Buyer commits a breach of any provision of this agreement (b) the appointment of a trustee, receiver or custodian for all or any part of Buyer’s property (c) the filing of a petition for relief in bankruptcy of the other Party on its own behalf, or by a third party (d) an assignment for the benefit of creditors, or (e) the dissolution or liquidation of the Buyer. 18. Governing Law. This agreement and the sale and delivery of all Products hereunder shall be deemed to have taken place in and shall be governed and construed in accordance with the laws of the State of Ohio, as applicable to contracts executed and wholly performed therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County, Ohio with respect to any dispute, controversy or claim arising out of or relating to this agreement. Disputes between the parties shall not be settled by arbitration unless, after a dispute has arisen, both parties expressly agree in writing to arbitrate the dispute. 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets or similar rights except as provided in this Section. Seller will defend and indemnify Buyer against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense and will pay the cost of any settlement or damages awarded in an action brought against Buyer based on an allegation that a Product sold pursuant to this Agreement infringes the Intellectual Property Rights of a third party. Seller’s obligation to defend and indemnify Buyer is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of such allegations of infringement, and Seller having sole control over the defense of any allegations or actions including all negotiations for settlement or compromise. If a Product is subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller may, at its sole expense and option, procure for Buyer the right to continue using the Product, replace or modify the Product so as to make it noninfringing, or offer to accept return of the Product and return the purchase price less a reasonable allowance for depreciation. Notwithstanding the foregoing, Seller shall have no liability for claims of infringement based on information provided by Buyer, or directed to Products delivered hereunder for which the designs are specified in whole or part by Buyer, or infringements resulting from the modification, combination or use in a system of any Product sold hereunder. The foregoing provisions of this Section shall constitute Seller’s sole and exclusive liability and Buyer’s sole and exclusive remedy for infringement of Intellectual Property Rights. 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise, sales, use, property, occupational or like taxes which may be imposed by any taxing authority upon the manufacture, sale or delivery of Products. 21. Equal Opportunity Clause. For the performance of government contracts and where dollar value of the Products exceed $10,000, the equal employment opportunity clauses in Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60741.5(a), and 60-250.4, are hereby incorporated. © 2011 Parker Hannifin Corporation Bulletin 10-10 / 411 Parker Hannifin Corporation Sporlan Division 206 Lange Drive • Washington, MO 63090 USA phone 636 239 1111 • fax 636 239 9130 www.sporlan.com
Similar documents
Type R Valves - Sporlan Online
Use the following formula to calculate TEV capacity: TEV Capacity = TEV rating x CF liquid temperature x CF pressure drop ERZE-2 has valve capacity of: 2.73 (9.38) x 1.06 (1.15) x 1.00 (1....
More information