THERMOSTATIC EXPANSION VALVES
Transcription
CATALOG 301 — Page 3 THERMOSTATIC EXPANSION VALVES 10 Outstanding Features & Benefits of Sporlan Thermostatic Expansion Valves n Selective Thermostatic Charges Designed to provide optimum performance for all applications—air conditioning and heat pump, medium and low temperature refrigeration. n Thermostatic Element Design Long lasting and field proven stainless steel diaphragm and welded element construction. n Diaphragm Design Large flat diaphragm permits precise valve control. n Replaceable Thermostatic Elements Field replaceable elements on all standard valves. n Balanced Port Design Provides perfect pin and port alignment, and prevents changes in pressure drop across the valve from influencing valve operation. Provides excellent control on applications with widely varying operating conditions. n Pin Carrier Design (Conventional Valves) Provides precise pin and port alignment, and tighter seating. n Accessible Internal Parts Durable, leakproof body joint construction allows the valve to be disassembled, and the internal parts cleaned and inspected. n Materials of Construction Pin and port materials offer maximum protection against corrosion and erosion. n Silver Soldered Connections For leakproof, high strength connection-to-body joints. n Adjustable Superheat Design All standard valves are externally adjustable. Valve Nomenclature/Ordering Instructions Combine the letters and numbers in the following manner to obtain the complete valve designation. Also include all connection sizes and the capillary tube length. EXAMPLE O Z E Sporlan Code – Refrigerant Element Label Color Code Body Type V = R-22 J = R-134a S = R-404A N = R-407C F = R-409A Z = R-410A P = R-507 Green Blue Orange Lt. Brown Yellow Rose Teal “E” specifies external equalizer. Omission of letter “E” indicates valve with internal equalizer. – 35 Nominal Capacity in Tons – GA Thermostatic Charge 7/8” ODF SOLDER x 1-1/8” ODF SOLDER x 1/4” ODF SOLDER x 5’ Inlet Connection Outlet Connection External Equalizer Connection Capillary Tubing Length Size and Style Size and Style Size and Style Inches or Feet Sporlan Selective Charges engineered for peak performance for each specific application Recommended Thermostatic Charges* APPLICATION Air Conditioning Commercial Refrigeration 10°C to -25°C Low Temperature Refrigeration -20°C to -40°C Extreme Low Temperature Refrigeration -40°C to -75°C * APPLICATION FACTORS: 22 134a 404A 407C 409A 410A 507 — VCP100 VGA — — — — VC — — — — VZ VZP40 — — JCP60 — — — — — JC — — — — — — — — — — — — SCP115 — — — — SC — — — — — SZ SZP — NCP100 NGA — — — — NC — — — — — — — — FCP60 — — — — — FC — — — FZ FZP — — — — — — — — ZCP200 ZGA — — — — — — — — — — — — — — — — — — — PC — — — — PZ PZP ACTUAL THERMOSTATIC CHARGES FCP60 VCP100 VGA SCP115 ZCP200 ZGA FC VC SC PC FZ FZP VZ VZP40 SZ SZP VX — — — — — — VX — — SX — — — PX SX REFRIGERANT 1. The Type ZP charges have essentially the same characteristics as the Type Z charge with one exception: they produce a pressure limit Maximum Operating Pressure (MOP). ZP charges are not intended as replacements for Z charges. Each should be selected for its own unique purpose. 2. All air conditioning and heat pump charges are intended for use with externally equalized valves. 3. Type L liquid charges are also available for most commonly used refrigerants in most element sizes. 4. If in doubt as to which charge to use, contact your nearest Sporlan Sales Office with complete system data. 5. The Type X charges are not to be used with “EBS” and “O” valves. Page 4 — CATALOG 301 THERMOSTATIC EXPANSION VALVES Quick Reference Guide NOMINAL CAPACITY RANGE (kW) VALVE TYPE SPECS R-22 R-404A R-410A R-134a & R-507 CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION ODF Solder Small brass body valve available only with straight through connections and external adjustment. The thermostatic element is not replaceable on valves manufactured prior to 1994. Current models use a replaceable No. 43 element. Typical applications: small capacity air conditioning and refrigeration applications where an external adjustment is desired. Not available for R-410A. ODF Solder Small brass body valve available with either angle style or straight through connection pattern. R valves are only available externally adjustable. The R has a balanced port construction, which makes it ideal for applications with a wide range of operating conditions. The design also provides exceptional control of refrigerant in both directions, making the R valve an excellent choice for heat pumps. ODF Solder In addition to the features described above for the R valve, the RC has a built-in check valve to allow bypass flow in the reverse direction. This feature makes this valve type ideally suited for heat pump applications. RC valves are only available externally adjustable. FB Page 6 0.88 thru 14 0.44 thru 10.5 0.44 thru 12.3 — R Page 7 3.5 thru 42 Page 8 3.5 thru 21 1.8 thru 31.5 1.8 thru 31.5 4.2 thru 50.8 — 4.2 thru 25.2 RC — Q/BQ Page 9-11 1.2 thru 17.5 0.58 thru 8.8 0.58 thru 10.5 1.5* thru 21.8 SAE Flare The brass body Q valve is externally adjustable with a removable cartridge or orifice. The valve body, cartridge and thermostatic element can be supplied as independent components. This allows body, cartridge and element to be assembled and matched to specific system requirements. Inlet connection has a 100 mesh removable strainer screen. Typical applications: Refrigeration applications and external equalized versions may be used on air conditioning. Type BQ same as above, with balanced port construction. *BQ only EQ/EBQ Page 9-11 1.2 thru 17.5 0.58 thru 8.8 0.58 thru 10.5 1.5* thru 21.8 Extended ODF Solder Type EQ same as the Type Q except it features extended ODF connections. A 100 mesh insert strainer is provided with the valve. Type EBQ same as EQ with balanced port construction. *EBQ only SQ/SBQ Page 9-11 1.2 thru 17.5 0.58 thru 8.8 0.58 thru 10.5 1.5* thru 21.8 Extended ODF Solder Type SQ same as the Type Q valve except it features ODF solder connections and a forged brass inlet fitting with a removable 100 mesh strainer screen which can be cleaned and/or replaced without removing the valve from the line. Type SBQ same as SQ with balanced port construction. *SBQ only CATALOG 301 — Page 5 THERMOSTATIC EXPANSION VALVES Quick Reference Guide NOMINAL CAPACITY RANGE (kW) VALVE TYPE SPECS R-22 R-404A R-410A R-134a & R-507 CONNECTION TYPES VALVE DESCRIPTION AND APPLICATION S Page 12 7 thru 52.5 7 thru 35 7 thru 35 — ODF Solder Brass bar body, externally adjustable valve. Inlet has a permanent 12 mesh strainer. General purpose valve for air conditioning and refrigeration applications. Page 13 28 thru 70 17.5 thru 42 21 thru 46 — Extended ODF Solder Same physical size as the Type S valve except it features extended ODF connections and a balanced port construction. ODF Solder Brass bar body, externally adjustable valve. Inlet has a permanent 12 mesh strainer. This valve features a balanced port construction, and it is suitable for both air conditioning and refrigeration applications. The valve can also be ordered as a bi-directional valve, allowing control of flow in both direction for use on heat pump applications. ODF Solder or FPT Flange Brass bar body, externally adjustable valve with flange connections. Inlet flange bushing has a permanent 16 mesh strainer. The FPT flange connection requires the K-1178 adapter kit. This valve provides the smallest capacity TEVs with flange connections and it is suitable for both air conditioning and refrigeration applications. ODF Solder or FPT Flange Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type provides valve capacities greater than the Type H and it is suitable for air conditioning and refrigeration applications. Flanges for the Type M valve are interchangeable with the Type V valve. ODF Solder or FPT Flange Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type features a dual port semi-balanced design. This valve type provides valve capacities greater than the Type M and is suitable for air conditioning and refrigeration applications. Flanges for the Type V are interchangeable with the Type M. ODF Solder Flange Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type features a dual port semi-balanced design and it is primarily for large capacity chillers. This valve type provides the largest valve capacities available for flange connection TEVs. EBS O Page 14 70 thru 315 42 thru 210 42 thru 193 70 thru 210 H Page 16 8.8 thru 70 5.3 thru 42 5.3 thru 42 — M Page 17 73.5 thru 147 52.5 thru 87.5 52.5 thru 105 — V Page 18 182 thru 350 123 thru 193 133 thru 245 — W Page 19 473 thru 630 280 thru 385 — — Page 6 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A 507 Type FB – Knife Edge Joint 49 mm Standard Cap Tube Length 30 inches (760 mm) The Type FB valve is an externally adjustable valve designed primarily for use in small capacity refrigeration applications. This valve may also be applied on residential and small commercial air conditioning, and heat pump units. Not available for R-410A. 90 mm 55 mm 46 mm Dimensions – Connections VALVE TYPE FB FITTING SIZE Inches 1/4 ODF 3/8 ODF 1/2 ODF A B mm A 43 43 — B — 34 34 30° Top View Bulb Sizes mm THERMOSTATIC CHARGE R-22 R-134a R-404A R-507 C 13 OD x 76 Z & ZP 13 OD x 76 — 13 OD x 76 1/4 ODF 46 mm 404A (S) 407C (N) 22 (V) 507 (P) FBJE-1/8 FBJE-1/4 FBJE-1/2 FBJE-1 FBJE-1-1/2 FBJE-2 FBJE-2-1/2 FBJE-3 FBSE-1/8 FBSE-1/4 FBSE-1/2 FBSE-1 FBSE-1-1/2 FBSE-2 FBSE-3 FBSE-3-1/2 FBNE-14 FBNE-1/2 FBNE-1 FBNE-1-1/2 FBNE-2 FBNE-2-1/2 FBNE-3 FBNE-4 FBPE-1/8 FBPE-1/4 FBPE-1/2 FBPE-1 FBPE-1-1/2 FBPE-2 FBPE-3 FBPE-3-1/2 0.44 0.88 1.75 3.5 5.25 7 8.75 10.5 0.44 0.88 1.75 3.5 5.25 7 10.5 12.25 0.88 1.75 3.5 5.25 7 8.75 10.5 14 0.44 0.88 1.75 3.5 5.25 7 10.5 12.25 STANDARD TUBING LENGTH mm CONNECTION – Inches Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 1/4, 3/8 3/8, 1/2 3/8 1/2 1/4, 3/8 3/8, 1/2 3/8 1/2 SHIPPING WEIGHT – kG 409A (F) FBJ-1/8 FBJ-1/4 FBJ-1/2 FBJ-1 FBJ-1-1/2 FBJ-2 FBJ-2-1/2 FBJ-3 FBS-1/8 FBS-1/4 FBS-1/2 FBS-1 FBS-1-1/2 FBS-2 FBS-3 FBS-3-1/2 FBN-1/4 FBN-1/2 FBN-1 FBN-1-1/2 FBN-2 FBN-2-1/2 FBN-3 FBN-4 FBP-1/8 FBP-1/4 FBP-1/2 FBP-1 FBP-1-1/2 FBP-2 FBP-3 FBP-3-1/2 EXTERNAL EQUALIZER NET WEIGHT – kG 134a (J) INTERNAL EQUALIZER THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) NOMINAL CAPACITY kW of Refrigeration Specifications – Element Size No. 43, Knife Edge Joint 0.45 0.68 C C Z ZP 760 C CP100 GA Z ZP40 C Z ZP 1/4, 3/8 3/8, 1/2 3/8 1/2 1/4, 3/8 3/8, 1/2 3/8 1/2 CATALOG 301 — Page 7 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A, 410A, 507 Type RE – Knife Edge Joint Standard Cap Tube Length 60 inches (1.5 m) 49 mm The Type RE valve is a small balanced port valve designed for use on refrigeration applications as well as residential and small commercial air conditioning and heat pump units. The balanced port design provides exceptional control of refrigerant in both directions, making this valve an excellent choice for heat pump systems. Dimensions – Connections VALVE TYPE RE1, 1-1/2 & 2* RE3, 4, 5, 6 & 8 RE12-1/2 & 15 FITTING SIZE Inches 3/8 ODF 1/2 ODF 3/8 ODF 1/2 ODF 5/8 ODF 7/8 ODF 5/8 ODF 7/8 ODF 7/8 ODF Ext. D C 46 mm A B E mm A 43 45 43 45 34 — 38 53 — B 63 63 63 63 63 61 — — 64 C 55 55 55 55 55 55 59 59 59 D 90 90 90 90 90 90 97 97 97 Bulb Sizes THERMOSTATIC CHARGE C Z CP100, CP200 GA ZP 30° Top View mm E 13 13 13 19 13 F 1/4” ODF 46 mm F 76 76 76 51 76 *1/2 ODF inlet available on 2 ton valves only. 134a (J) 409A (F) 404A (S) 507 (P) 410A (Z) 3.5 5.25 7 10.5 14 17.5 21 28 35 42 1.75 3.5 5.25 7 8.75 10.5 14 1.75 3.5 5.25 7 10.5 12.25 14 4.20 7.35 9.66 13.4 17.6 21.0 25.2 33.6 43.8 50.8 43 C CP100 GA Z ZP40 45-5 43 C 1.5 43 45 45-5 C Z ZP Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 3/8 1/2 1/2 5/8 5/8 7/8 5/8 7/8 Ext. 3/8 1/2 1/2 5/8 3/8 1/2 1/2 5/8 3/8 1/2 1/2 5/8 5/8 7/8 5/8 7/8 Ext. SHIPPING WEIGHT – kG 22 (V) RNE-1 RNE-1-1/2 RNE-2 RNE-3 RNE-4 RNE-5 RNE-6 RNE-8 RNE-10 RNE-12 RJE-1/2 RJE-1 RJE-1-1/2 RJE-2 RJE-2-1/2 RJE-3 RJE-4 RSE-1/2 RSE-1 RSE-1-1/2 RSE-2 RSE-3 RSE-3-1/2 RSE-4 RZE-1 RZE-1-1/2 RZE-2 RZE-3 RZE-4 RZE-5 RZE-6 RZE-8 RZE-12-1/2 RZE-15 ELEMENT SIZE NO. CONNECTION – Inches1 ODF NET WEIGHT – kG 407C (N) VALVE TYPE STANDARD TUBING LENGTH m REFRIGERANT (Sporlan Code) NOMINAL CAPACITY kW of Refrigeration THERMOSTATIC CHARGES AVAILABLE Specifications 0.45 0.68 CP200 GA Q Valves are also available as special order with SAE connections. Note: Valves with SAE inlet and outlet fittings are available only with the 1/4”SAE flare external equalizer; valves with ODF fittings are available only with the 1/4” ODF external equalizer. Note: Valves can be supplied with internal equalizer on valves with nominal capacity of 2 or less. Page 8 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 22, 407C, 410A Type RCE – Knife Edge Joint 49 mm Standard Cap Tube Length 30 inches (760 mm) Type RC valves contain internal check valves to allow reverse flow on heat pump applications. This eliminates the need for an external check valve piped around the TEV for reverse flow. The RC valve can be used on Heat Pump and Air Conditioning (cooling only) applications. Exact replacement valves for the CBI, CBBI, BI, and I valves are available from the OEM and should be ordered from the OEM during the warranty period of the equipment, or when special features such as specific bleed ports, connections, configurations, capillary tube lengths, etc. are required. Replaceable elements available for these valves are the following: R-22, Element Kit Number KT-43-VGA-30”, and R-410A, Element Kit Number KT-45-ZGA-30”. 93 mm 58 mm A Top View D 46 mm C B 30° 1.90” 48 mm The Type RC thermostatic expansion valves are only available with the specifications shown below. Dimensions – Connections VALVE TYPE FITTING SIZE – Inches 3/8 ODF 1/2 ODF 5/8 ODF 3/8 ODF 1/2 ODF 5/8 ODF RCE1, 1-1/2 & 2 RCE3, 4, 5 & 6 mm A 48.8 50.3 — 48.8 50.3 — B 36.8 36.8 38.9 36.8 36.8 38.9 Bulb Sizes mm THERMOSTATIC CHARGE NGA NCP100 ZCP200 ZGA C 19 13 13 19 D 51 76 76 51 *1/2 ODF inlet available on 2 ton valves only. 410A (Z) 1/4 SAE 1/4 ODF 1/4 ODF 3.5 5.3 7.0 11 14 18 21 4.20 7.36 9.66 13.4 17.6 21.0 25.2 STANDARD TUBING LENGTH mm INLET OUTLET 3/8 1/2 1/2 1/2 SHIPPING WEIGHT – kG 22 (V) RCNE-1 RCNE-1-1/2 RCNE-2-GA RCNE-3-GA RCNE-4-GA RCNE-5-GA RCNE-6-GA RCZE-1 RCZE-1-1/2 RCZE-2-GA RCZE-3-GA RCZE-4-GA RCZE-5-GA RCZE-6-GA CONNECTION – Inches1 Blue figures are standard and will be furnished unless otherwise specified. NET WEIGHT – kG 407C (N) VALVE TYPE EXTERNAL EQUALIZER 23 THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) NOMINAL CAPACITY kW of Refrigeration Specifications – Element Size No. 43 (No. 45 for R-410A), Knife Edge Joint 0.57 0.68 CP100 GA 760 CP200 GA 3/8 1/2 1/2 1/2 1/2 5/8 Q Valves are also available as special order with Chatleff connections. W Valves with SAE inlet and outlet fittings are available only with the 1/4”SAE flare external equalizer; valves with ODF fittings are available only with the 1/4” ODF external equalizer. E Valves with Chatleff fittings are available only with the 1/8” OD x 24” long tube with flare and nut external equalizer. CATALOG 301 — Page 9 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A, 410A, 507 Type Q and BQ The Series Q and BQ are replaceable cartridge style thermostatic expansion valves, available in both conventional (Type Q) and balanced port (Type BQ) configurations. These valves can be supplied as a complete valve or as three component parts, body, cartridge, and thermostatic element. They are designed for small refrigeration systems, including refrigerated cases, coolers and freezers, and are also well suited for air conditioning and heat pump duty. Strainer U.S. Patent No. 5,232,015 U.S. Patent No. 5,238,219 R-134a R-409A R-410A SIZE CARTRIDGE CODE COLOR CODE SERIES Q CARTRIDGE R-404A R-507 0.88 2.63 3.5 5.25 8.75 10.5 17.5 0.44 0.88 1.75 3.5 5.25 7 10.5 0.44 0.88 1.75 3.5 5.25 7 10.5 0.44 0.88 1.75 3.5 5.25 7 10.5 — — — — — — — 0 1 2 3 4 5 6 QC-0 QC-1 QC-2 QC-3 QC-4 QC-5 QC-6 Red Yellow Green Blue Pink Black White SERIES BQ NOMINAL CAPACITY (kW) R-22 R-407C 1.16 2.35 5.25 10.5 19.25 0.7 1.16 3.5 6.13 10.5 0.7 1.16 3.5 6.13 10.5 0.7 1.16 3.5 6.13 10.5 1.17 2.64 6.15 12.3 21.1 AAA AA A B C BQC-AAA BQC-AA BQC-A BQC-B BQC-C Red Yellow Blue Pink White Q valve not suitable for R-410A. BQ valve cartridges are available with 15% bleed port. Q – Valve Nomenclature/Ordering Instructions QE – O (1/3T) – V C – 3/8” x 1/2” x 1/4 x 5’ Valve Type Q, EQ, SQ = Internally Equalized Cartridge Size QE, EQE, SQE = Externally Equalized Nominal Capacity (Tons) Refrigerant Code Thermostatic Charge Inlet Connection Size Outlet Connection Size External Equalizer Connection Size BQ – Valve Nomenclature/Ordering Instructions BQE – AAA – V C – 3/8” x 1/2” x 1/4 x 5’ Valve Type BQ, EBQ, SBQ = Internally Equalized BQE, EBQE, SBQE = Externally Equalized Cartridge Size Refrigerant Code Thermostatic Charge Inlet Connection Size Outlet Connection Size External Equalizer Connection Size Capillary Tubing Length Inches or Feet Capillary Tubing Length Inches or Feet Page 10 — CATALOG 301 THERMOSTATIC EXPANSION VALVES Selecting Body Type Q/BQ EQ/EBQ SQ/SBQ SAE Internally Equalized ODF Internally Equalized QE/BQE ODF Internally Equalized EQE/EBQE SQE/SBQE Replaceable Strainer •U.S. Patent No. 5,232,015 •P/N 3427-000 SAE Externally Equalized ODF Externally Equalized ODF Externally Equalized U.S. Patent No. 5,238,219 Q/BQ & QE/BQE Options EQ &EBQ Options EQE & EBQE Options SQ/SBQ & SQE/SBQE Options Inlet x Outlet Inlet x Outlet Inlet x Outlet Inlet x Outlet 1/4 x 3/8 SAE, 90° Angle Inlet 1/4 x 1/2 SAE, 90° Angle Inlet 3/8 x 1/2 SAE, 90° Angle Inlet 3/8 x 1/2 ODF, Straight Thru 3/8 x 1/2 ODF, 90° Angle Inlet 3/8 x 1/2 ODF, Straight Thru 3/8 x 5/8 ODF, Straight Thru 1/2 x 5/8 ODF, Straight Thru 1/2 x 7/8 ODF, Straight Thru 3/8 x 1/2 ODF, 90° Angle Inlet 3/8 x 1/2 SAE, 90° Angle Inlet Selecting The Element Abbreviation for “Kit” – 43 – Element Size Number V C *Refrigerant Code Thermostatic Charge Bulb R-22 KT-43-VC CO • WASHING LVE TO VA N, AN M RL MADE IN U.S. of A. O O KT Capillary Tube Length Standard = 60 inches (1.5 meters) 43 VC DATE 4499 Date Code Label (by week and year of manufacture) SP Element Label See page 3 for thermostatic charges available. BQ valves for R-410A, use KT-45 element. Selecting The Cartridge – See table on previous page for cartridge codes. Q Valve Cartridge Service Kit – Part No. 184000 AAA - Red Qty. 2 AA - Yellow Qty. 4 Oil Bottle BQ Cartridge Tool No. 6 - White Qty. 3 S PO BQ RL A B - Pink Qty. 1 B - Pink Qty. 2 Oil Bottle C 6 A - Blue Qty. 4 B No. 5 - Black Qty. 3 No. 4 - Pink Qty. 3 N 5 No. 3 - Blue Qty. 5 4 B 4 mm Allen Wrench No. 2 - Green Qty. 5 3 A No. 1 - Yellow Qty. 5 2 AA No. 0 - Red Qty. 3 1 AAA 0 BQ Valve Cartridge Service Kit – Part No. 184007 C - White Qty. 2 CATALOG 301 — Page 11 THERMOSTATIC EXPANSION VALVES Type Q, QE, BQ, & BQE Dimensions – Connections 49 mm FITTING SIZE Inches 1/4 SAE, 90° Angle 3/8 SAE, 90° Angle 3/8 SAE 1/2 SAE mm B — — 41 46 A 30 34 — — C 37 27 — — Top View 100 mm 1/4 SAE Removable Strainer P/N 3008-000 64 mm C 60° 51 mm 3/8 SAE Inlet Strainer P/N 1538-000 A 39 mm B Dimensions – Connections Type EQ, EQE, EBQ, & EBQE 49 mm FITTING SIZE Inches 3/8 1/2 5/8 7/8 64 mm B — 63 63 61 60° Top View 3/8 ODF Insert Strainer P/N 877-003 100 mm mm A 64 61 — — I/2 ODF Insert Strainer P/N 877-004 (EBQE Only) 51 mm 47 mm A View of 90° elbow inlet B Type SQ, SQE, SBQ, & SBQE 49 mm 64 mm Removable Strainer P/N 3427-000 47 mm 100 mm Top View 64 mm 60° 51 mm 47 mm 35 mm 63 mm Series Q & BQ Bulb Sizes – mm STANDARD CHARGES C Z & ZP CP VGA REFRIGERANT 22 134a 13 OD x 76 — 404A 13OD x 76 13 OD x 76 19 OD x 51 507 13 OD x 76 — Page 12 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 507 Type S 58.5 mm Standard Cap Tube Length 60 inches (1.5 m) 42 mm Sporlan Type S valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve is designed for both air conditioning and refrigeration applications. Dimensions – Connections VALVE TYPE S 54 mm 90 mm Diameter of Type X Charge Diaphragm Case is 92 mm mm FITTING SIZE Inches 3/8 ODF 1/2 ODF 5/8 ODF 7/8 ODF 1-1/8 ODF A 34 33 38 — — B — 34.5 40 54 55.5 Bulb Sizes STANDARD CHARGES C Z & ZP Series X CP Series VGA B A 30° 22 13 OD x 89 19 OD x 102 19 OD x 51 36 mm ODF Solder REFRIGERANT 134a 404A 507 13 OD x 89 – 13 OD x 89 – 19 OD x 102 13 OD x 89 – – – – 1/4” ODF External Equalizer Connection Top View 134a (J) 409A (F) 404A (S) 507 (P) SNE-2 SNE-3 SNE-4 SNE-5 SNE-8 SNE-10 SNE-15 SJE-2 SJE-2-1/2 SJE-3 SJE-5 SJE-6 SJE-10 SSE-2 SSE-3 SSE-4 SSE-6 SSE-7 SSE-10 SPE-2 SPE-3 SPE-4 SPE-6 SPE-7 SPE-10 7.0 11 14 18 28 35 56.5 7.0 8.8 11 18 21 35 7.0 11 14 21 25 35 7.0 11 14 21 25 35 STANDARD TUBING LENGTH m SN-2 SN-3 SN-4 SN-5 — — — SJ-2 SJ-2-1/2 SJ-3 — — — SS-2 SS-3 SS-4 — — — SP-2 SP-3 SP-4 — — — 1.5 INLET OUTLET 3/8 or 1/2 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 7/8 3/8 or 1/2 1-1/8 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 7/8 3/8 or 1/2 1-1/8 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 7/8 3/8 or 1/2 1-1/8 5/8, 7/8 or 1-1/8 1/2 5/8, 7/8 or 1-1/8 5/8 7/8 or 1-1/8 7/8 1-1/8 QValves listed in this column NOT AVAILABLE with MOP Type air conditioning charges. WODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing. Note: S Valves not available for R-410A. SHIPPING WEIGHT - kg 22 (V) EXTERNAL EQUALIZER CONNECTIONS - Inches W ODF Solder Blue figures are standard and will be furnished unless otherwise specified. NET WEIGHT - kg 407C (N) INTERNAL EQUALIZER Q THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) Refer to Recommended Thermostatic Charges on page 3 VALVE TYPE NOMINAL CAPACITY kW of Refrigeration Specifications – Element Size No. 83, Knife Edge Joint 0.9 1.4 CATALOG 301 — Page 13 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A, 507 Type EBS 58.5 mm Standard Cap Tube Length 60 inches (1.5 m) Sporlan Type EBS valve is a brass bar body valve having the same physical size as the Type S valve except the Type EBS features a balanced port construction and extended ODF connections. The thermostatic element is replaceable. The balanced port construction makes this valve ideally suited for refrigeration and air conditioning applications which operate over widely varying conditions. 46 mm C C 85 mm 87 mm (EBSVE-20 only) 70 mm (EBSVE-20 only) 72 mm Dimensions – Connections VALVE TYPE EBS FITTING SIZE Inches 3/8 ODF 1/2 ODF 5/8 ODF 7/8 ODF 1-1/8 ODF A 62 62 62 — — mm B — — 64 64 77 C 9 13 19 20.5 24.5 1/4” ODF External Equalizer Connection Bulb Sizes STANDARD CHARGES C Z & ZP Series CP Series VGA 22 13 OD x 89 19 OD x 51 B A REFRIGERANT 134a 404A 507 13 OD x 89 – 13 OD x 89 13 OD x 89 – – – – 30° Top View 134a (J) 409A (F) 404A (S) 507 (P) STANDARD TUBING LENGTH m INLET OUTLET EBSNE-8 28 1/2 or 5/8 7/8 or 1-1/8 EBSNE-11 39 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 EBSNE-15 53 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 7/8 1-1/8 or 1-3/8 EBSNE-20 70 EBSJE-5 18 EBSJE-7 25 EBSJE-9 32 EBSJE-12 42 EBSSE-6 21 EBSSE-7-1/2 26 EBSSE-10 35 EBSSE-13 46 EBSPE-6 21 EBSPE-7-1/2 1.5 1/2 or 5/8 7/8 or 1-1/8 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 7/8 1-1/8 or 1-3/8 1/2 or 5/8 7/8 or 1-1/8 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 7/8 1-1/8 or 1-3/8 1/2 or 5/8 7/8 or 1-1/8 26 1/2, 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 EBSPE-10 35 5/8 or 7/8 7/8, 1-1/8 or 1-3/8 EBSPE-13 46 7/8 1-1/8 or 1-3/8 EXTERNAL EQUALIZER 1/4 Pointed Toward Bottom Cap or Parallel to Outlet Connection QODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing. * X charge not available. Note: Not suitable for bi-directional flow control. SHIPPING WEIGHT - kg 22 (V) CONNECTIONS - Inches Q Extended ODF Solder Blue figures are standard and will be furnished unless otherwise specified. NET WEIGHT - kg 407C (N) EXTERNAL EQUALIZER *Refer to Recommended Thermostatic Charges on page 3 REFRIGERANT (Sporlan Code) THERMOSTATIC CHARGES AVAILABLE VALVE TYPE NOMINAL CAPACITY kW of Refrigeration Specifications – Element Size No. 83, Knife Edge Joint 0.9 1.4 Page 14 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A, 410A, 507 Type O This valve type has two body styles: a small body which provides capacities up to 133 kW R-407C, and a large body which extends capacities to 315 kW R-407C. Sporlan Type O valve is a brass bar body, externally adjustable valve with ODF solder connections. The thermostatic element is replaceable, and the inlet connection has a permanent 12 mesh strainer. This valve type features a balanced port construction, and it is designed for both air conditioning and refrigeration applications. A synthetic seating surface provides tight shut-off during system off periods. The valve can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications. Standard Cap Tube Length 60 inches (1.5 m) U.S. Patent No. 3,742,722 409A (F) 404A (S) 507 (P) 407C (N) 22 (V) 410A (Z) INLET OUTLET 1-3/8 1-1/8 33 83 33 83 33-8 33 0.9 1.4 1.8 2.3 0.9 1.4 1.8 2.3 0.9 1.4 1.8 2.3 0.9 1.4 1.8 2.3 1-1/8 7/8 83 SHIPPING WEIGHT - kg 134a (J) CONNECTIONS - Inches 2 ODF Solder Blue figures are standard and will be furnished unless otherwise specified. NET WEIGHT - kg 42 56 81 112 133 140 42 74 105 123 133 158 70 105 133 140 193 215 315 70 84 116 175 210 STANDARD TUBING LENGTH m OJE-12 OJE-16 OJE-23 OJE-32 OJE-38 OJE-40 OSE-12 OSE-21 OSE-30 OSE-35 OSE-38 OSE-45 ONE-20 ONE-30 ONE-38 ONE-40 ONE-55 ONE-70 ONE-90 OZE-20 OZE-25 OZE-35 OZE-50 OZE-60 THERMOSTATIC CHARGES AVAILABLE Q EXTERNAL EQUALIZER 1-3/8 or 1-5/8 1-1/8 7/8 *Refer to Recommended Thermostatic Charges on page 3 REFRIGERANT (Sporlan Code) NOMINAL CAPACITY kW of Refrigeration VALVE TYPE THERMOSTATIC ELEMENT SIZE NO. Specifications – Element Size No. 83, No. 33, No. 85 (R-410A), and No. 85-3 (R-410A), Knife Edge Joint 1-3/8 1-1/8 1-3/8 or 1-5/8 1.5 1-1/8 7/8 1-3/8 1-1/8 1-3/8 or 1-5/8 63-3 85 85-3 7/8 1-1/8 1-1/8 1-3/8 QStandard External Equalizer Connection 1/4” ODF Solder, 1/4” SAE flare connection available on request. 2ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing. * X charge not available. O – Valve Nomenclature/Ordering Instructions O Valve Type V Refrigerant Code E External Equalizer – B Optional Bi-Directional Feature – 20 Nominal Capacity – GA Thermostatic Charge x 7/8” Inlet Connection Size x 1-3/8” Outlet Connection Size x 1/4” External Equalizer Connection Size x 5’ Capillary Tubing Length Inches or Feet CATALOG 301 — Page 15 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 410A, 507 Type O with Number 83 or 85 Element 59 mm 1/4” ODF External Equalizer Connection 36 mm 43 mm 62 mm Top View C Dimensions – Connections VALVE TYPE O FITTING SIZE Inches 7/8 ODF 1-1/8 ODF 1-3/8 ODF A 53 56 — C mm B — 57 61 C 19 25 25 105 mm Bulb Sizes STANDARD CHARGES C Z & ZP Series CP Series VGA ZGA A 22 13 OD x 89 19 OD x 51 — REFRIGERANT 404A 134a 13 OD x 89 — 13 OD x 89 — — 13 OD x 89 — — 410A — — — — 19 OD x 51 B 507 13 OD x 89 13 OD x 89 — — — Type O with Number 33 or 85-3 Element 70 mm R-22 35 Element 59 mm R-410A 85-3 Element 59 mm 1/4” ODF External Equalizer Connection 40 mm 49 mm 74 mm Top View C C 140 mm Dimensions – Connections VALVE TYPE O FITTING SIZE Inches 1-1/8 ODF 1-3/8 ODF 1-5/8 ODF A 68 — — mm B — 76 79 C 23 25 28 A Bulb Sizes STANDARD CHARGES C Z & ZP Series CP Series VGA ZGA 22 19OD x 102 19OD x 102 19 OD x 102 — 134a 13 OD x 127 — 19 OD x 102 — — REFRIGERANT 404A 19 OD x 102 19 OD x 102 — — 410A — — — — 19 OD x 51 507 19 OD x 102 19 OD x 102 — — — B Page 16 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A, 507 Type H 70 mm Brass bar body, externally adjustable valve with flange connections. Inlet flange bushing has a permanent 16 mesh strainer. The FPT flange connection requires the K-1178 adapter kit. This valve provides the smallest capacity TEVs with flange connections and it is suitable for both air conditioning and refrigeration applications. 52 mm Dimensions – Connections VALVE TYPE H 114 mm mm SOLDERING BUSHING 1/2 5/8 7/8 1-1/8 A 51 51 51 52 B B B 22 22 22 24 A A Diameter of Type X Charge Diaphragm Case Is 92 mm Bulb Sizes STANDARD CHARGES C Z & ZP Series X CP Series VGA 22 19 OD x 102 19 OD x 102 19 OD x 102 19 OD x 102 REFRIGERANT 134a 404A 507 13 OD x 127 19 OD x 102 — 19 OD x 102 — 19 OD x 102 19 OD x 102 — — — — REFRIGERANT (Sporlan Code) 134a (J) 409A (F) 404A (S) 507 (P) 407C (N) 22 (V) WINTERNAL EQUALIZER HJ-1-1/2 HJ-3 HJ-4 HJ-5 — — HS-1-1/2 HS-3 HS-4 — — — HN-2-1/2 HN-5-1/2 — — — — EEXTERNAL EQUALIZER HJE-1-1/2 HJE-3 HJE-4 HJE-5 HJE-8 HJE-12 HSE-1-1/2 HSE-3 HSE-4 HSE-6-1/2 HSE-9 HSE-12 HVE-2-1/2 HVE-5-1/2 HVE-7 HVE-11 HVE-16 HVE-20 Refer to Recommended Thermostatic Charges on Page 3 TYPE & CAPACITY THERMOSTATIC CHARGES AVAILABLE Specifications – Element Size No. 33, Gasket Joint, Standard Tubing Length 1.5 Meters5 Flange Ring Size – 1-1/4” OD x 1” ID. QSTANDARD CONNECTIONS Inches RODF SOLDER FLANGE Blue figures are standard and will be furnished unless otherwise specified. INLET 1/2 OUTLET 5/8 5/8 7/8 7/8 1/2 1-1/8 5/8 5/8 7/8 7/8 1/2 1-1/8 5/8 5/8 7/8 7/8 1-1/8 Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order. W Valves listed in this column NOT AVAILABLE with MOP Type air conditioning charges. E Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request. R ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. 5 Tubing lengths other than standard available upon special order at an additional cost. NOTE: The H valve is not available for R-410A. External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors. CATALOG 301 — Page 17 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A, 507 Type M 92 mm Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type provides valve capacities greater than the Type H and it is suitable for air conditioning and refrigeration applications. Flanges for the Type M valve are interchangeable with the Type V valve. 71 mm Dimensions – Connections VALVE TYPE H SOLDERING BUSHING 7/8 1-1/8 1-3/8 1-5/8 B mm A 60 70 70 82 125 mm B 22 24 24 31 Bulb Sizes STANDARD CHARGES C Z & ZP Series X CP Series VGA 22 22 OD x 152 22 OD x 152 19 OD x 102 B A REFRIGERANT 134a 404A 507 22 OD x 152 — 22 OD x 152 — 22 OD x 152 19 OD x 102 — — — — Diameter of Type X Charge Diaphragm Case Is 121 mm A Specifications – Element Size No. 63, Gasket Joint, TYPE & CAPACITY 134a (J) 409A (F) 2EXTERNAL EQUALIZER MJE-15 MJE-20 MJE-25 MSE-15 404A (S) 507 (P) MSE-20 MSE-25 MSE-30 MNE-21 407C (N) 22 (V) MNE-26 MNE-34 MNE-42 Refer to Recommended Thermostatic Charges on Page 3 REFRIGERANT (Sporlan Code) THERMOSTATIC CHARGES AVAILABLE Standard Tubing Length 1.5 Meters4 Flange Ring Size – 1-3/4” OD x 1-1/4” ID. QSTANDARD CONNECTIONS Inches 3ODF SOLDER FLANGE Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 7/8 1-1/8 7/8 1-1/8 1-1/8 7/8 1-1/8 Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order. 2 Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request. 3 ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. 4 Tubing lengths other than standard available upon special order at an additional cost. NOTE: The M valve is not available for R-410A. External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors. Page 18 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 22, 134a, 404A, 407C, 409A, 507 Type V 92 mm Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type features a dual port semi-balanced design. This valve type provides valve capacities greater than the Type M and is suitable for air conditioning and refrigeration applications. Flanges for the Type V are interchangeable with the Type M. 106 mm B B Dimensions – Connections VALVE TYPE V SOLDERING BUSHING 7/8 1-1/8 1-3/8 1-5/8 mm A 60 70 70 82 122 mm B 22 24 24 31 A Bulb Sizes STANDARD CHARGES C Z & ZP Series X CP Series VGA 22 22 OD x 152 22 OD x 152 19 OD x 102 A REFRIGERANT 134a 404A 507 22 OD x 152 — 22 OD x 152 — 22 OD x 152 19 OD x 102 — — — — Specifications – Element Size No. 63, REFRIGERANT (Sporlan Code) 134a (J) 409A (F) 404A (S) 507 (P) 407C (N) 22 (V) 2EXTERNAL EQUALIZER VJE-35 VJE-45 VJE-55 VSE-38 VSE-50 VSE-70 VNE-52 VNE-70 VNE-100 Refer to Recommended Thermostatic Charges on Page 3 TYPE & CAPACITY THERMOSTATIC CHARGE AVAILABLE Gasket Joint, Standard Tubing Length 1.5 Meters4 Flange Ring Size – 1-3/4” OD x 1-1/2” ID. QSTANDARD CONNECTION Inches 3ODF SOLDER FLANGE Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 1-3/8 1-3/8 Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order. 2 Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request. 3 ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. 4 Tubing lengths other than standard available upon special order at an additional cost. NOTE: The V valve is not available for R-410A. External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors. Diameter of Type X Charge Diaphragm Case Is 121 mm CATALOG 301 — Page 19 THERMOSTATIC EXPANSION VALVES 22, 134a, 407C, 409A Type W * Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type features a dual port semi-balanced design and it is primarily for large capacity chillers. This valve type provides the largest valve capacities available for flange connection TEVs. 116 mm Dimensions – Connections VALVE TYPE FITTING SIZE W 1-1/8 1-3/8 1-5/8 2-1/8 D mm A 28 35 41 54 B 32 39 45 62 C 27 33 38 49 D 23 25 28 34 E 40 41 44 39 F 78 80 83 83 155 mm Bulb Sizes STANDARD CHARGES C Z & ZP Series X CP Series VGA G REFRIGERANT ELEMENT SIZE 22 NUMBER 63 7 *Diameter of Diaphragm Case is 92 mm for Small W and 121 mm for Large W 134a 22 OD x 152 22 OD x 152 22 OD x 152 19 OD x 102 19 OD x 102 19 OD x 102 F F 86 mm — — — — B A E 64 mm 19 mm 3 mm 13 mm - Diameter Bolt Holes C 52 mm 71 mm Specifications – Element Size No. 63, Small Capacity No. 7 Large Capacity – Gasket 134a (J) 409A (F) 407C (N) 22 (V) 2EXTERNAL EQUALIZER THERMOSTATIC CHARGES AVAILABLE REFRIGERANT (Sporlan Code) ELEMENT SIZE NUMBER Joint, Standard Tubing Length 3 Meters5 Flange Ring Size – 2-3/4” OD x 2-3/16” ID. TYPE & CAPACITY WJE-80 63 4 WJE-110 7 G only WNE-135 63 4 WNE-180 7 G only A B QSTANDARD CONNECTIONS Inches 3ODF SOLDER FLANGE Blue figures are standard and will be furnished unless otherwise specified. INLET OUTLET 1-5/8 2-1/8 Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order. 2 Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request. 3 ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing. 4 Refer to Recommended Thermostatic Charges, Page 3. 5 Tubing lengths other than standard available upon special order at an additional cost. NOTE: The W valve is not available for R-410A. External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors. E Page 20 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 134a, 409A Air Conditioning, Heat Pump and Commercial Refrigeration Applications VALVE TYPES NOMINAL CAPACITY kW 5° FB FB FB FB FB FB-S FB-S S S S S H H H H H H M M M 0.44 0.88 1.8 3.5 5.3 7.0 8.8 11 18 21 35 5.3 11 14 18 28 42 53 70 88 0.76 1.51 2.85 4.80 5.97 8.17 10.2 12.3 20.6 24.7 38.2 6.54 12.3 16.3 20.4 30.6 47.8 63.3 81.7 102 REFRIGERANT 134a 409A RECOMMENDED THERMOSTATIC CHARGE JC, JCP60 FC, FCP60 EVAPORATOR TEMPERATURE °C -5° -15° 5° -5° 0.89 1.77 3.35 5.64 7.01 8.73 10.9 13.1 18.8 22.5 36.3 6.99 13.1 17.5 21.8 32.8 51.1 67.7 87.3 109 0.80 1.59 3.01 5.07 6.30 8.01 10.0 12.0 15.6 18.7 31.1 6.40 11.3 15.1 18.8 28.2 44.0 56.7 73.2 91.5 0.76 1.52 2.87 4.83 6.01 8.23 10.3 12.3 20.7 24.9 38.4 6.58 12.3 16.4 20.6 30.8 48.1 63.7 82.3 103 -15° 0.90 1.80 3.39 5.71 7.10 8.84 11.0 13.3 19.0 22.8 36.7 7.07 13.3 17.7 22.1 33.1 51.7 68.5 88.4 110 0.81 1.62 3.06 5.15 6.41 8.15 10.2 12.2 15.8 19.0 31.7 6.52 11.5 15.3 19.1 28.7 44.8 57.7 74.5 93.1 2.90 5.07 6.66 9.27 12.2 14.5 17.4 21.0 28.9 36.7 51.7 68.5 109 152 190 155 199 243 376 — 2.62 4.58 6.02 8.37 11.0 13.1 14.6 18.1 25.0 30.0 42.3 60.4 94.2 131 164 128 164 201 296 — BALANCED PORT THERMOSTATIC EXPANSION VALVES R R R R R R R EBS EBS EBS EBS-O O O O O V V V W W 1.8 3.5 5.3 7.0 8.8 11 14 18 25 32 42 56 81 110 140 120 160 190 280 390 VALVE TYPE CARTRIDGE Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ 0 1 2 3 4 5 6 VALVE TYPE CARTRIDGE BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ AAA AA A B C 2.44 4.27 5.61 7.80 10.2 12.2 14.6 20.8 28.7 38.1 47.8 63.3 96.6 130 163 143 184 225 347 486 2.86 5.01 6.58 9.16 12.0 14.3 17.2 20.7 28.6 36.3 51.1 67.7 108 150 188 153 197 240 371 — 2.57 4.50 5.91 8.23 10.8 12.9 14.3 17.8 24.6 29.5 41.5 59.4 92.6 129 161 126 162 198 291 — 2.45 4.29 5.64 7.85 10.3 12.3 14.7 21.0 28.9 38.4 48.1 63.7 94.2 131 164 144 185 226 350 490 CONVENTIONAL CARTRIDGE THERMOSTATIC EXPANSION VALVES 0.59 0.88 1.8 3.5 5.3 7.0 8.8 0.82 1.84 2.65 4.08 5.72 8.17 11.0 0.87 1.97 2.84 4.37 6.11 8.73 11.8 0.80 1.80 2.60 4.00 5.60 8.01 10.8 0.82 1.85 2.67 4.11 5.76 8.23 11.1 0.88 1.99 2.87 4.42 6.19 8.84 11.9 0.82 1.83 2.65 4.07 5.70 8.15 11.0 BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES 0.70 1.2 3.5 7.0 11 0.85 1.84 4.08 6.94 12.3 LIQUID TEMPERATURE ENTERING TEV °C REFRIGERANT -10° 0° 10° 20° 30° 40° 50° 60° CORRECTION FACTOR, CF LIQUID TEMPERATURE 134a 1.64 1.52 1.39 1.26 1.13 1.00 0.87 0.73 409A 1.51 1.41 1.31 1.21 1.11 1.00 0.89 0.78 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from -15°C to 5°C since the variation in the actual factors across this range is insignificant. 0.99 1.97 4.37 7.42 13.1 0.95 1.80 4.00 6.80 12.0 EVAPORATOR TEMPERATURE °C 5° -5° & -15° 0.85 1.85 4.11 6.99 12.3 1.00 1.99 4.42 7.51 13.3 0.97 1.83 4.07 6.92 12.2 PRESSURE DROP ACROSS TEV (bar) 2 4 6 8 10 12 14 16 CORRECTION FACTOR, CF PRESSURE DROP 0.71 1.00 1.22 1.41 1.58 1.73 1.87 2.00 0.58 0.82 1.00 1.15 1.29 1.41 1.53 1.63 TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 1-1/2 ton R-134a Type FB valve at -5°C evaporator, 8 bar pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 7.01 (from rating chart) x 1.13 (CF liquid temperature) x 1.15 (CF pressure drop) = 9.11 kW. CATALOG 301 — Page 21 THERMOSTATIC EXPANSION VALVES 22, 407C Air Conditioning, Heat Pump and Commercial Refrigeration Applications REFRIGERANT 22 407C RECOMMENDED THERMOSTATIC CHARGE VC, VCP100, VGA VZ, VZP40 NC, NCP100, NGA EVAPORATOR TEMPERATURE °C 5° -5° -15° -20° -30° -40° 5° -5° -15° VALVE TYPES NOMINAL CAPACITY FB FB FB FB FB-S FB-S FB-S S S S S H H H H H H M M M M 0.88 1.8 3.5 5.3 7.0 11 14 18 28 35 53 8.8 19 25 39 56 70 74 91 120 150 R-RC R-RC R-RC R-RC R-RC R-RC R-RC R R R EBS EBS EBS EBS-O O O O O O O V V V W W 3.5 5.3 7.0 11 14 18 21 28 35 44 28 39 53 70 110 130 140 190 250 320 180 250 350 470 630 3.21 5.62 7.39 10.3 13.5 16.1 19.3 25.7 33.5 38.9 27.4 37.0 49.7 71.9 98.2 122 129 177 235 289 167 235 321 459 607 1.2 2.6 3.5 5.3 8.8 12 18 1.12 2.41 3.21 4.82 8.03 11.2 15.4 1.2 2.3 5.3 11 18 1.12 2.41 5.14 8.99 16.7 kW 1.00 1.99 3.76 6.01 6.87 10.9 13.4 16.7 25.7 32.1 49.8 8.04 18.0 22.5 33.8 48.9 71.4 69.0 85.1 109 135 1.12 2.25 4.24 6.78 7.75 12.3 15.1 18.8 29.0 36.2 56.2 8.90 19.9 24.9 37.4 54.1 79.1 77.9 96.0 123 152 1.03 2.06 3.88 6.21 7.10 11.3 13.9 17.0 24.6 30.8 47.7 8.12 18.2 22.7 34.1 49.4 72.1 75.3 92.9 119 147 1.04 2.08 3.69 5.68 6.78 10.6 13.1 16.4 23.4 29.3 46.1 8.12 18.0 21.7 31.6 45.6 68.9 74.8 96.7 120 151 0.80 1.61 2.52 3.57 4.68 7.17 8.77 11.8 15.9 19.8 31.2 5.09 11.1 12.5 17.0 24.3 39.5 53.6 75.7 89.1 107 0.63 1.25 1.96 2.78 3.65 5.59 6.84 9.22 12.3 15.3 24.9 4.28 9.34 10.5 14.3 20.4 33.2 45.2 63.9 75.2 86.2 0.91 1.81 3.42 5.47 6.26 9.94 12.2 15.2 23.4 29.2 45.3 7.32 16.4 20.5 30.7 44.5 65.0 62.9 77.5 99.4 123 1.01 2.02 3.80 6.08 6.96 11.1 13.6 16.9 26.0 32.5 50.4 7.99 17.9 22.4 33.5 48.6 70.9 69.9 86.1 111 137 0.91 1.82 3.43 5.48 6.27 9.97 12.3 15.0 21.8 27.2 42.2 7.17 16.1 20.1 30.1 43.6 63.7 66.5 82.0 105 130 1.96 2.78 3.65 5.25 6.84 7.83 8.00 9.27 — — 13.0 17.5 23.4 29.6 49.1 60.9 74.6 83.0 90.4 111 101 138 178 255 — 2.92 5.12 6.72 9.35 12.3 14.6 17.5 23.4 30.5 35.4 24.9 33.7 45.3 65.5 89.4 111 118 161 214 263 152 214 292 418 553 3.25 5.69 7.48 10.4 13.7 16.3 19.5 26.0 33.9 39.3 26.5 35.8 48.8 68.8 94.9 118 130 177 235 290 168 235 322 461 — 2.93 5.13 6.74 9.38 12.3 14.7 16.3 23.4 30.6 35.5 22.4 30.3 38.6 53.7 81.1 97.3 102 139 184 226 159 224 306 438 — 1.14 2.44 3.25 4.88 8.13 11.4 15.6 1.01 2.16 2.88 4.33 7.21 10.1 13.8 1.14 2.44 5.20 9.10 16.9 1.01 2.16 4.61 8.08 15.0 BALANCED PORT THERMOSTATIC EXPANSION VALVES VALVE TYPE CARTRIDGE Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ 0 1 2 3 4 5 6 VALVE TYPE CARTRIDGE BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ AAA AA A B C 3.62 6.34 8.33 11.6 15.2 18.1 21.7 29.0 37.8 43.8 29.5 39.9 54.4 76.7 106 132 145 198 262 323 187 262 359 514 — 3.32 5.81 7.63 10.6 13.9 16.6 18.5 26.5 34.6 40.1 25.4 34.3 43.7 60.8 91.8 110 115 157 209 255 180 253 347 496 — 3.32 5.42 7.12 10.0 13.1 15.4 16.8 23.2 — — 24.5 33.1 42.0 58.3 84.8 102 111 150 198 243 190 265 355 507 — 2.52 3.57 4.68 6.73 8.77 10.0 10.4 12.0 — — 16.8 22.7 29.1 40.2 56.5 70.3 86.1 98.2 111 137 121 167 214 307 — CONVENTIONAL CARTRIDGE THERMOSTATIC EXPANSION VALVES 1.27 2.72 3.62 5.43 9.06 12.7 17.4 1.14 2.45 3.27 4.90 8.16 11.4 15.7 1.10 2.50 3.27 4.65 8.25 11.4 15.1 0.79 1.99 2.52 3.22 6.43 8.77 10.7 0.62 1.55 1.96 2.51 5.02 6.84 8.33 1.02 2.19 2.92 4.39 7.31 10.2 14.0 BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES LIQUID TEMPERATURE ENTERING TEV °C REFRIGERANT -10° 0° 10° 20° 30° 40° 50° 60° CORRECTION FACTOR, CF LIQUID TEMPERATURE 22 1.52 1.42 1.32 1.21 1.11 1.00 0.89 0.78 407C 1.73 1.59 1.45 1.30 1.15 1.00 0.84 0.67 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from -15°C to 5°C since the variation in the actual factors across this range is insignificant. 1.27 2.72 5.80 10.1 18.8 1.14 2.45 5.23 9.14 17.0 EVAPORATOR TEMPERATURE °C 5° -5° & -15° -20° & -30° -40° 1.10 2.50 5.03 8.95 16.4 0.79 1.99 3.57 6.58 11.8 0.62 1.55 2.78 5.13 9.22 1.02 2.19 4.68 8.19 15.2 PRESSURE DROP ACROSS TEV (bar) 2 4 6 8 10 12 14 16 CORRECTION FACTOR, CF PRESSURE DROP 0.58 0.82 1.00 1.15 1.29 1.41 1.53 1.63 0.50 0.71 0.87 1.00 1.12 1.22 1.32 1.41 0.45 0.63 0.77 0.89 1.00 1.10 1.18 1.26 0.41 0.58 0.71 0.82 0.91 1.00 1.08 1.15 TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 1-1/2 ton R-22 Type FB valve at -5°C evaporator, 10 bar pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 6.78 (from rating chart) x 1.11 (CF liquid temperature) x 1.12 (CF pressure drop) = 8.43 kW. Page 22 — CATALOG 301 THERMOSTATIC EXPANSION VALVES 404A, 507 Air Conditioning, Heat Pump and Commercial Refrigeration Applications REFRIGERANT 404A VALVE TYPES NOMINAL CAPACITY kW 5° -5° -15° RECOMMENDED THERMOSTATIC CHARGE SZ, SZP PC EVAPORATOR TEMPERATURE °C -20° -30° -40° 5° -5° -15° FB FB FB FB FB FB-S FB-S S S S S H H H H H H M M M M 0.44 0.88 1.8 3.5 5.3 7.0 11 14 21 25 35 5.3 11 14 23 32 42 53 70 88 110 0.65 1.12 2.25 3.90 4.46 6.43 8.72 12.9 17.8 22.7 32.5 4.84 9.04 12.9 21.0 30.7 42.0 50.8 66.2 82.6 99.6 0.71 1.24 2.47 4.29 4.91 7.01 9.59 14.0 17.1 21.8 31.8 4.85 9.05 12.9 21.0 30.7 42.0 55.8 72.8 90.8 110 0.63 1.10 2.20 3.81 4.36 6.17 8.49 12.1 14.4 18.4 28.4 4.54 7.80 10.7 17.4 25.5 34.9 45.3 57.5 71.7 86.5 0.62 1.12 2.11 3.43 4.12 6.42 7.90 12.3 15.2 19.3 30.3 4.94 8.23 11.3 18.0 24.1 34.9 46.4 58.2 70.9 84.2 R R R R R R R EBS EBS EBS EBS O O O O O V V V 1.8 3.5 5.3 7.0 11 12 14 21 26 35 46 42 74 110 120 160 130 180 250 1.92 3.65 4.80 6.65 8.76 10.4 12.5 18.1 24.5 30.2 43.1 42.0 67.8 97.1 113 145 122 164 225 0.59 0.88 1.8 3.5 5.3 7.0 11 0.64 1.45 2.09 3.22 5.14 6.75 9.00 0.70 1.2 3.5 7.0 11 0.72 1.45 3.21 5.95 9.00 SCP115, SC 0.45 0.86 1.47 2.08 2.78 4.17 5.12 9.45 12.3 15.6 26.2 3.99 6.65 9.31 14.5 16.6 26.6 39.6 49.7 58.3 67.5 0.33 0.65 1.10 1.56 2.09 3.13 3.84 8.15 9.89 12.6 23.5 3.30 5.51 7.71 12.0 13.8 22.0 33.2 41.7 48.9 56.6 0.64 1.10 2.21 3.83 4.39 6.32 8.57 12.6 17.5 22.3 31.9 4.76 8.88 12.7 20.6 30.1 41.2 49.9 65.0 81.1 97.9 507 PZ, PZP -20° -30° -40° 0.70 1.21 2.43 4.21 4.82 6.88 9.41 13.8 16.8 21.4 31.3 4.76 8.88 12.7 20.6 30.1 41.3 54.8 71.4 89.1 108 0.62 1.08 2.16 3.75 4.29 6.06 8.34 11.9 14.2 18.0 27.9 4.46 7.66 10.5 17.1 25.0 34.2 44.5 56.5 70.4 85.0 0.61 1.10 2.07 3.38 4.05 6.44 7.77 12.1 14.9 19.0 29.8 4.86 8.09 11.1 17.7 23.7 34.4 45.6 57.2 69.7 82.8 0.44 0.85 1.45 2.05 2.74 4.11 5.05 9.31 12.1 15.4 25.8 3.93 6.55 9.17 14.3 16.4 26.2 39.0 48.9 57.4 66.5 0.33 0.64 1.09 1.54 2.06 3.09 3.79 8.05 9.77 12.4 23.2 3.26 5.44 7.62 11.8 13.6 21.8 32.8 41.2 48.3 55.9 2.07 3.94 5.18 7.18 9.46 11.3 13.5 18.3 24.8 31.2 45.1 41.3 66.6 104 120 155 127 171 235 1.85 3.51 4.61 6.39 8.41 10.0 11.2 15.4 21.0 24.9 35.3 33.6 50.2 80.3 93.1 120 111 149 207 1.87 3.22 4.22 5.93 7.80 9.17 10.0 15.2 20.2 24.2 34.1 33.7 45.5 71.6 81.2 101 115 158 220 1.45 2.05 2.67 3.86 5.05 5.77 6.05 10.5 13.3 17.6 25.2 26.8 32.1 48.0 52.2 60.1 96.1 137 192 1.09 1.54 2.01 2.90 3.79 4.34 4.50 9.75 12.4 15.3 20.2 23.2 27.8 41.6 45.2 52.1 79.2 113 158 0.69 1.56 2.20 3.00 4.95 6.54 8.51 0.54 1.22 1.60 2.31 3.99 5.32 6.65 0.47 1.06 1.39 2.00 3.45 4.60 5.75 0.80 1.56 3.63 5.60 8.51 0.66 1.22 2.99 4.34 6.65 0.57 1.06 2.58 3.76 5.75 BALANCED PORT THERMOSTATIC EXPANSION VALVES VALVE TYPE CARTRIDGE Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ Q-EQ-SQ 0 1 2 3 4 5 6 VALVE TYPE CARTRIDGE BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ AAA AA A B C 2.11 4.01 5.28 7.31 9.63 11.5 13.8 18.6 25.3 31.7 45.9 42.0 67.9 106 123 158 130 174 239 1.88 3.57 4.69 6.50 8.56 10.2 11.4 15.7 21.3 25.3 36.0 34.2 51.1 81.7 94.7 122 113 152 211 1.91 3.28 4.30 6.04 7.93 9.32 10.2 15.4 20.5 24.6 34.7 34.3 46.3 72.8 82.6 103 117 160 223 1.47 2.08 2.71 3.92 5.12 5.85 6.14 10.6 13.5 17.9 25.5 27.2 32.6 48.8 52.9 61.0 97.5 139 195 1.10 1.56 2.03 2.94 3.84 4.39 4.55 9.87 12.6 15.4 20.5 23.5 28.1 42.1 45.7 52.7 80.2 114 160 1.89 3.59 4.71 6.54 8.61 10.2 12.3 17.7 24.1 29.6 42.3 41.2 66.6 95.4 111 142 120 161 221 CONVENTIONAL CARTRIDGE THERMOSTATIC EXPANSION VALVES 0.71 1.59 2.33 3.50 5.60 7.36 9.81 0.67 1.50 2.21 3.03 4.85 6.37 8.49 0.70 1.58 2.23 3.06 5.04 6.65 8.65 0.55 1.24 1.63 2.34 4.05 5.40 6.75 0.48 1.07 1.40 2.02 3.49 4.66 5.82 0.63 1.42 2.05 3.16 5.05 6.63 8.84 0.69 1.56 2.29 3.44 5.50 7.22 9.63 0.66 1.48 2.18 2.98 4.77 6.26 8.34 BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES 0.80 1.59 3.59 6.48 9.81 LIQUID TEMPERATURE ENTERING TEV °C REFRIGERANT -10° 0° 10° 20° 30° 40° 50° 60° CORRECTION FACTOR, CF LIQUID TEMPERATURE 404A 1.98 1.79 1.60 1.41 1.21 1.00 0.79 0.56 507 1.92 1.74 1.56 1.37 1.19 1.00 0.79 0.54 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from -15°C to 5°C since the variation in the actual factors across this range is insignificant. 0.75 1.50 3.41 5.61 8.49 0.82 1.58 3.70 5.69 8.65 EVAPORATOR TEMPERATURE °C 5° -5° & -15° -20° & -30° -40° 0.67 1.24 3.03 4.41 6.75 0.58 1.07 2.61 3.80 5.82 0.71 1.42 3.15 5.84 8.84 0.78 1.56 3.53 6.36 9.63 0.74 1.48 3.35 5.51 8.34 PRESSURE DROP ACROSS TEV (bar) 2 4 6 8 10 12 14 16 CORRECTION FACTOR, CF PRESSURE DROP 0.58 0.82 1.00 1.15 1.29 1.41 1.53 1.63 0.50 0.71 0.87 1.00 1.12 1.22 1.32 1.41 0.45 0.63 0.77 0.89 1.00 1.10 1.18 1.26 0.41 0.58 0.71 0.82 0.91 1.00 1.08 1.15 TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 1-1/2 ton R-404A Type FB valve at -5°C evaporator, 10 bar pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 4.91 (from rating chart) x 1.21 (CF liquid temperature) x 1.12 (CF pressure drop) = 6.65 kW. CATALOG 301 — Page 23 THERMOSTATIC EXPANSION VALVES 410A Air Conditioning and Heat Pump Applications REFRIGERANT 410A NOMINAL RECOMMENDED THERMOSTATIC CHARGE CAPACITY VALVE TYPES ZGA EVAPORATOR TEMPERATURE °C kW 5° -5° -15° BALANCED PORT THERMOSTATIC EXPANSION VALVES R-RC R-RC R-RC R-RC R-RC R-RC R-RC R R R O O O O O 3.5 5.3 7.0 11 14 18 21 28 44 53 70 88 120 180 210 VALVE TYPE CARTRIDGE BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ BQ-EBQ-SBQ AAA AA A B C REFRIGERANT 410A 4.08 7.14 9.38 13.1 17.1 20.4 24.5 32.6 42.5 49.4 68.1 81.7 112 170 204 4.50 7.88 10.4 14.4 18.9 22.5 27.0 36.0 46.9 54.4 75.1 90.1 124 188 225 4.12 7.21 9.48 13.2 17.3 20.6 23.0 33.0 43.0 49.9 71.5 85.8 118 179 215 BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES 1.2 2.6 5.3 11 18 1.43 3.06 6.53 11.4 21.2 LIQUID TEMPERATURE ENTERING TEV °C 20° 30° 40° 50° 60° CORRECTION FACTOR, CF LIQUID TEMPERATURE 1.30 1.15 1.00 0.84 0.65 These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they may be used for any evaporator temperature from -15°C to 5°C since the variation in the actual factors across this range is insignificant. 1.58 3.38 7.20 12.6 23.4 EVAPORATOR TEMPERATURE °C 5° -5° & -15° 1.42 3.04 6.49 11.4 21.1 PRESSURE DROP ACROSS TEV (bar) 8 11 14 17 20 CORRECTION FACTOR, CF PRESSURE DROP 0.85 1.00 1.13 1.24 1.35 0.76 0.89 1.00 1.10 1.20 TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example: Actual capacity of a nominal 4 ton R-410A Type RC valve at -15°C evaporator, 17 bar pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 17.3 (from rating chart) x 1.15 (CF liquid temperature) x 1.10 (CF pressure drop) = 21.9 kW.
Similar documents
Catalog 301 - Sporlan Online
1. The Type ZP charges have essentially the same characteristics as the Type Z charge with one exception: they produce a pressure limit Maximum Operating Pressure (MOP). ZP charges are not intend...
More informationCatalog 201 - Sporlan Online
FOR REFRIGERANTS: 22, 134a, 401A, 402A, 404A, 407C, 408A, 409A, 410A, 422D, 507 TEV capacity ratings for R-22, R-134a, R-401A, R-402A, R-404A, R-407C, R-408A, R-409A, R-410A, R-422D, and R-507 are ...
More informationDanfoss Catalog
Examples of typical applications include: • Traditional refrigeration systems • Air conditioning systems • Transport refrigeration systems By pairing one valve body with one of eight replaceable...
More informationtable of contents
on Page 9. These ratings are based on vapor free 86°F liquid refrigerant entering the TEV, a maximum opening superheat of 7°F, and a standard factory air test setting. For TEV capacity ratings at o...
More information