CATALOG 301 — Page 3
THERMOSTATIC EXPANSION VALVES
10 Outstanding Features & Benefits of Sporlan Thermostatic Expansion Valves
n  Selective Thermostatic Charges Designed to provide
optimum performance for all applications—air conditioning and heat pump, medium and low temperature
refrigeration.
n  Thermostatic Element Design Long lasting and field
proven stainless steel diaphragm and welded element
construction.
n  Diaphragm Design Large flat diaphragm permits precise
valve control.
n  Replaceable Thermostatic Elements Field replaceable
elements on all standard valves.
n  Balanced Port Design Provides perfect pin and port
alignment, and prevents changes in pressure drop across
the valve from influencing valve operation. Provides
excellent control on applications with widely varying operating conditions.
n  Pin Carrier Design (Conventional Valves) Provides precise pin and port alignment, and tighter seating.
n  Accessible Internal Parts Durable, leakproof body joint
construction allows the valve to be disassembled, and the
internal parts cleaned and inspected.
n  Materials of Construction Pin and port materials offer
maximum protection against corrosion and erosion.
n  Silver Soldered Connections For leakproof, high strength
connection-to-body joints.
n  Adjustable Superheat Design All standard valves are
externally adjustable.
Valve Nomenclature/Ordering Instructions
Combine the letters and numbers in the following manner to obtain the complete valve designation. Also include all connection sizes and
the capillary tube length.
EXAMPLE
O
Z
E
Sporlan Code – Refrigerant
Element Label Color Code
Body
Type
V = R-22
J = R-134a
S = R-404A
N = R-407C
F = R-409A
Z = R-410A
P = R-507
Green
Blue
Orange
Lt. Brown
Yellow
Rose
Teal
“E”
specifies
external
equalizer.
Omission
of letter
“E”
indicates
valve with
internal
equalizer.
–
35
Nominal
Capacity
in Tons
–
GA
Thermostatic
Charge
7/8” ODF
SOLDER
x
1-1/8” ODF
SOLDER
x
1/4” ODF
SOLDER
x
5’
Inlet
Connection
Outlet
Connection
External
Equalizer
Connection
Capillary
Tubing
Length
Size and
Style
Size and
Style
Size and
Style
Inches or
Feet
Sporlan Selective Charges engineered for peak performance for each specific application
Recommended Thermostatic Charges*
APPLICATION
Air Conditioning
Commercial
Refrigeration
10°C to -25°C
Low Temperature
Refrigeration
-20°C to -40°C
Extreme Low Temperature
Refrigeration
-40°C to -75°C
* APPLICATION FACTORS:
22
134a
404A
407C
409A
410A
507
—
VCP100
VGA
—
—
—
—
VC
—
—
—
—
VZ
VZP40
—
—
JCP60
—
—
—
—
—
JC
—
—
—
—
—
—
—
—
—
—
—
—
SCP115
—
—
—
—
SC
—
—
—
—
—
SZ
SZP
—
NCP100
NGA
—
—
—
—
NC
—
—
—
—
—
—
—
—
FCP60
—
—
—
—
—
FC
—
—
—
FZ
FZP
—
—
—
—
—
—
—
—
ZCP200
ZGA
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
PC
—
—
—
—
PZ
PZP
ACTUAL
THERMOSTATIC
CHARGES
FCP60
VCP100
VGA
SCP115
ZCP200
ZGA
FC
VC
SC
PC
FZ
FZP
VZ
VZP40
SZ
SZP
VX
—
—
—
—
—
—
VX
—
—
SX
—
—
—
PX
SX
REFRIGERANT
1.  The Type ZP charges have essentially the same characteristics as the Type Z charge with one exception: they produce a pressure limit Maximum Operating Pressure (MOP). ZP charges are not
intended as replacements for Z charges. Each should be selected for its own unique purpose.
2.  All air conditioning and heat pump charges are intended for use with externally equalized valves.
3.  Type L liquid charges are also available for most commonly used refrigerants in most element sizes.
4.  If in doubt as to which charge to use, contact your nearest Sporlan Sales Office with complete system data.
5.  The Type X charges are not to be used with “EBS” and “O” valves.
Page 4 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
Quick Reference Guide
NOMINAL CAPACITY RANGE (kW)
VALVE TYPE
SPECS
R-22
R-404A R-410A
R-134a &
R-507
CONNECTION
TYPES
VALVE DESCRIPTION AND APPLICATION
ODF Solder
Small brass body valve available only with straight
through connections and external adjustment. The
thermostatic element is not replaceable on valves
manufactured prior to 1994. Current models use a replaceable No. 43 element. Typical applications: small
capacity air conditioning and refrigeration applications where an external adjustment is desired. Not
available for R-410A.
ODF Solder
Small brass body valve available with either angle
style or straight through connection pattern. R valves
are only available externally adjustable. The R has a
balanced port construction, which makes it ideal for
applications with a wide range of operating conditions. The design also provides exceptional control of
refrigerant in both directions, making the R valve an
excellent choice for heat pumps.
ODF Solder
In addition to the features described above for the R
valve, the RC has a built-in check valve to allow bypass
flow in the reverse direction. This feature makes this
valve type ideally suited for heat pump applications. RC
valves are only available externally adjustable.
FB
Page 6
0.88
thru
14
0.44
thru
10.5
0.44
thru
12.3
—
R
Page 7
3.5
thru
42
Page 8
3.5
thru
21
1.8
thru
31.5
1.8
thru
31.5
4.2
thru
50.8
—
4.2
thru
25.2
RC
—
Q/BQ
Page
9-11
1.2
thru
17.5
0.58
thru
8.8
0.58
thru
10.5
1.5*
thru
21.8
SAE Flare
The brass body Q valve is externally adjustable with
a removable cartridge or orifice. The valve body, cartridge and thermostatic element can be supplied as
independent components. This allows body, cartridge
and element to be assembled and matched to specific
system requirements. Inlet connection has a 100 mesh
removable strainer screen. Typical applications: Refrigeration applications and external equalized versions may be used on air conditioning. Type BQ same
as above, with balanced port construction.
*BQ only
EQ/EBQ
Page
9-11
1.2
thru
17.5
0.58
thru
8.8
0.58
thru
10.5
1.5*
thru
21.8
Extended
ODF Solder
Type EQ same as the Type Q except it features extended
ODF connections. A 100 mesh insert strainer is provided
with the valve. Type EBQ same as EQ with balanced port
construction.
*EBQ only
SQ/SBQ
Page
9-11
1.2
thru
17.5
0.58
thru
8.8
0.58
thru
10.5
1.5*
thru
21.8
Extended
ODF Solder
Type SQ same as the Type Q valve except it features
ODF solder connections and a forged brass inlet fitting
with a removable 100 mesh strainer screen which can
be cleaned and/or replaced without removing the valve
from the line. Type SBQ same as SQ with balanced port
construction.
*SBQ only
CATALOG 301 — Page 5
THERMOSTATIC EXPANSION VALVES
Quick Reference Guide
NOMINAL CAPACITY RANGE (kW)
VALVE TYPE
SPECS
R-22
R-404A R-410A
R-134a &
R-507
CONNECTION
TYPES
VALVE DESCRIPTION AND APPLICATION
S
Page
12
7
thru
52.5
7
thru
35
7
thru
35
—
ODF Solder
Brass bar body, externally adjustable valve. Inlet has a
permanent 12 mesh strainer. General purpose valve for
air conditioning and refrigeration applications.
Page
13
28
thru
70
17.5
thru
42
21
thru
46
—
Extended
ODF Solder
Same physical size as the Type S valve except it features extended ODF connections and a balanced port
construction.
ODF Solder
Brass bar body, externally adjustable valve. Inlet has a
permanent 12 mesh strainer. This valve features a balanced port construction, and it is suitable for both air
conditioning and refrigeration applications. The valve
can also be ordered as a bi-directional valve, allowing
control of flow in both direction for use on heat pump
applications.
ODF Solder
or
FPT Flange
Brass bar body, externally adjustable valve with flange
connections. Inlet flange bushing has a permanent 16
mesh strainer. The FPT flange connection requires the
K-1178 adapter kit. This valve provides the smallest
capacity TEVs with flange connections and it is suitable for both air conditioning and refrigeration applications.
ODF Solder
or
FPT Flange
Cast bronze body, externally adjustable valve with
flange connections. Inlet has a 12 mesh strainer. This
valve type provides valve capacities greater than the
Type H and it is suitable for air conditioning and refrigeration applications. Flanges for the Type M valve are
interchangeable with the Type V valve.
ODF Solder
or
FPT Flange
Cast bronze body, externally adjustable valve with
flange connections. Inlet has a 12 mesh strainer. This
valve type features a dual port semi-balanced design.
This valve type provides valve capacities greater
than the Type M and is suitable for air conditioning
and refrigeration applications. Flanges for the Type V
are interchangeable with the Type M.
ODF Solder
Flange
Cast bronze body, externally adjustable valve with
flange connections. Inlet has a 12 mesh strainer. This
valve type features a dual port semi-balanced design
and it is primarily for large capacity chillers. This valve
type provides the largest valve capacities available for
flange connection TEVs.
EBS
O
Page
14
70
thru
315
42
thru
210
42
thru
193
70
thru
210
H
Page
16
8.8
thru
70
5.3
thru
42
5.3
thru
42
—
M
Page
17
73.5
thru
147
52.5
thru
87.5
52.5
thru
105
—
V
Page
18
182
thru
350
123
thru
193
133
thru
245
—
W
Page
19
473
thru
630
280
thru
385
—
—
Page 6 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A 507
Type FB – Knife Edge Joint
49 mm
Standard Cap Tube Length 30 inches
(760 mm)
The Type FB valve is an externally adjustable
valve designed primarily for use in small
capacity refrigeration applications. This valve
may also be applied on residential and small
commercial air conditioning, and heat pump
units. Not available for R-410A.
90 mm
55 mm
46 mm
Dimensions – Connections
VALVE
TYPE
FB
FITTING SIZE
Inches
1/4 ODF
3/8 ODF
1/2 ODF
A
B
mm
A
43
43
—
B
—
34
34
30°
Top View
Bulb Sizes
mm
THERMOSTATIC
CHARGE
R-22
R-134a
R-404A
R-507
C
13 OD x 76
Z & ZP
13 OD x 76
—
13 OD x 76
1/4 ODF
46 mm
404A (S)
407C (N)
22 (V)
507 (P)
FBJE-1/8
FBJE-1/4
FBJE-1/2
FBJE-1
FBJE-1-1/2
FBJE-2
FBJE-2-1/2
FBJE-3
FBSE-1/8
FBSE-1/4
FBSE-1/2
FBSE-1
FBSE-1-1/2
FBSE-2
FBSE-3
FBSE-3-1/2
FBNE-14
FBNE-1/2
FBNE-1
FBNE-1-1/2
FBNE-2
FBNE-2-1/2
FBNE-3
FBNE-4
FBPE-1/8
FBPE-1/4
FBPE-1/2
FBPE-1
FBPE-1-1/2
FBPE-2
FBPE-3
FBPE-3-1/2
0.44
0.88
1.75
3.5
5.25
7
8.75
10.5
0.44
0.88
1.75
3.5
5.25
7
10.5
12.25
0.88
1.75
3.5
5.25
7
8.75
10.5
14
0.44
0.88
1.75
3.5
5.25
7
10.5
12.25
STANDARD
TUBING LENGTH
mm
CONNECTION – Inches
Blue figures are standard and will be
furnished unless otherwise specified.
INLET
OUTLET
1/4, 3/8
3/8, 1/2
3/8
1/2
1/4, 3/8
3/8, 1/2
3/8
1/2
SHIPPING
WEIGHT – kG
409A (F)
FBJ-1/8
FBJ-1/4
FBJ-1/2
FBJ-1
FBJ-1-1/2
FBJ-2
FBJ-2-1/2
FBJ-3
FBS-1/8
FBS-1/4
FBS-1/2
FBS-1
FBS-1-1/2
FBS-2
FBS-3
FBS-3-1/2
FBN-1/4
FBN-1/2
FBN-1
FBN-1-1/2
FBN-2
FBN-2-1/2
FBN-3
FBN-4
FBP-1/8
FBP-1/4
FBP-1/2
FBP-1
FBP-1-1/2
FBP-2
FBP-3
FBP-3-1/2
EXTERNAL
EQUALIZER
NET WEIGHT
– kG
134a (J)
INTERNAL
EQUALIZER
THERMOSTATIC
CHARGES
AVAILABLE
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
kW of
Refrigeration
Specifications – Element Size No. 43, Knife Edge Joint
0.45
0.68
C
C
Z
ZP
760
C
CP100
GA
Z
ZP40
C
Z
ZP
1/4, 3/8
3/8, 1/2
3/8
1/2
1/4, 3/8
3/8, 1/2
3/8
1/2
CATALOG 301 — Page 7
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A, 410A, 507
Type RE – Knife Edge Joint
Standard Cap Tube Length 60 inches
(1.5 m)
49 mm
The Type RE valve is a small balanced
port valve designed for use on refrigeration
applications as well as residential and
small commercial air conditioning and
heat pump units. The balanced port design provides exceptional
control of refrigerant in both directions, making this valve an
excellent choice for heat pump systems.
Dimensions – Connections
VALVE
TYPE
RE1, 1-1/2 & 2*
RE3, 4, 5, 6 & 8
RE12-1/2 & 15
FITTING SIZE
Inches
3/8 ODF
1/2 ODF
3/8 ODF
1/2 ODF
5/8 ODF
7/8 ODF
5/8 ODF
7/8 ODF
7/8 ODF Ext.
D
C
46 mm
A
B
E
mm
A
43
45
43
45
34
—
38
53
—
B
63
63
63
63
63
61
—
—
64
C
55
55
55
55
55
55
59
59
59
D
90
90
90
90
90
90
97
97
97
Bulb Sizes
THERMOSTATIC
CHARGE
C
Z
CP100, CP200
GA
ZP
30°
Top View
mm
E
13
13
13
19
13
F
1/4” ODF
46 mm
F
76
76
76
51
76
*1/2 ODF inlet available on 2 ton valves only.
134a (J)
409A (F)
404A (S)
507 (P)
410A (Z)
3.5
5.25
7
10.5
14
17.5
21
28
35
42
1.75
3.5
5.25
7
8.75
10.5
14
1.75
3.5
5.25
7
10.5
12.25
14
4.20
7.35
9.66
13.4
17.6
21.0
25.2
33.6
43.8
50.8
43
C
CP100
GA
Z
ZP40
45-5
43
C
1.5
43
45
45-5
C
Z
ZP
Blue figures are standard
and will be furnished unless
otherwise specified.
INLET
OUTLET
3/8
1/2
1/2
5/8
5/8
7/8
5/8
7/8 Ext.
3/8
1/2
1/2
5/8
3/8
1/2
1/2
5/8
3/8
1/2
1/2
5/8
5/8
7/8
5/8
7/8 Ext.
SHIPPING
WEIGHT – kG
22 (V)
RNE-1
RNE-1-1/2
RNE-2
RNE-3
RNE-4
RNE-5
RNE-6
RNE-8
RNE-10
RNE-12
RJE-1/2
RJE-1
RJE-1-1/2
RJE-2
RJE-2-1/2
RJE-3
RJE-4
RSE-1/2
RSE-1
RSE-1-1/2
RSE-2
RSE-3
RSE-3-1/2
RSE-4
RZE-1
RZE-1-1/2
RZE-2
RZE-3
RZE-4
RZE-5
RZE-6
RZE-8
RZE-12-1/2
RZE-15
ELEMENT
SIZE NO.
CONNECTION – Inches1
ODF
NET WEIGHT
– kG
407C (N)
VALVE TYPE
STANDARD
TUBING LENGTH
m
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
kW of
Refrigeration
THERMOSTATIC
CHARGES
AVAILABLE
Specifications
0.45
0.68
CP200
GA
Q Valves are also available as special order with SAE connections.
Note: Valves with SAE inlet and outlet fittings are available only with the 1/4”SAE flare external equalizer; valves with ODF fittings are available only with the 1/4” ODF external equalizer.
Note: Valves can be supplied with internal equalizer on valves with nominal capacity of 2 or less.
Page 8 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
22, 407C, 410A
Type RCE – Knife Edge Joint
49 mm
Standard Cap Tube Length 30 inches
(760 mm)
Type RC valves contain internal check
valves to allow reverse flow on heat pump
applications. This eliminates the need for an
external check valve piped around the TEV
for reverse flow. The RC valve can be used on Heat Pump and Air
Conditioning (cooling only) applications.
Exact replacement valves for the CBI, CBBI, BI, and I valves are
available from the OEM and should be ordered from the OEM
during the warranty period of the equipment, or when special
features such as specific bleed ports, connections, configurations,
capillary tube lengths, etc. are required.
Replaceable elements available for these valves are the following:
R-22, Element Kit Number KT-43-VGA-30”, and R-410A, Element
Kit Number KT-45-ZGA-30”.
93 mm
58 mm
A
Top View
D
46 mm
C
B
30°
1.90”
48 mm
The Type RC thermostatic expansion valves are only available with
the specifications shown below.
Dimensions – Connections
VALVE TYPE
FITTING SIZE – Inches
3/8 ODF
1/2 ODF
5/8 ODF
3/8 ODF
1/2 ODF
5/8 ODF
RCE1, 1-1/2 & 2
RCE3, 4, 5 & 6
mm
A
48.8
50.3
—
48.8
50.3
—
B
36.8
36.8
38.9
36.8
36.8
38.9
Bulb Sizes
mm
THERMOSTATIC
CHARGE
NGA
NCP100
ZCP200
ZGA
C
19
13
13
19
D
51
76
76
51
*1/2 ODF inlet available on 2 ton valves only.
410A (Z)
1/4 SAE
1/4 ODF
1/4 ODF
3.5
5.3
7.0
11
14
18
21
4.20
7.36
9.66
13.4
17.6
21.0
25.2
STANDARD
TUBING LENGTH
mm
INLET
OUTLET
3/8
1/2
1/2
1/2
SHIPPING
WEIGHT – kG
22 (V)
RCNE-1
RCNE-1-1/2
RCNE-2-GA
RCNE-3-GA
RCNE-4-GA
RCNE-5-GA
RCNE-6-GA
RCZE-1
RCZE-1-1/2
RCZE-2-GA
RCZE-3-GA
RCZE-4-GA
RCZE-5-GA
RCZE-6-GA
CONNECTION – Inches1
Blue figures are standard
and will be furnished unless
otherwise specified.
NET WEIGHT
– kG
407C (N)
VALVE TYPE
EXTERNAL
EQUALIZER
23
THERMOSTATIC
CHARGES
AVAILABLE
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
kW of
Refrigeration
Specifications – Element Size No. 43 (No. 45 for R-410A), Knife Edge Joint
0.57
0.68
CP100
GA
760
CP200
GA
3/8
1/2
1/2
1/2
1/2
5/8
Q Valves are also available as special order with Chatleff connections.
W Valves with SAE inlet and outlet fittings are available only with the 1/4”SAE flare external equalizer; valves with ODF fittings are available only with the 1/4” ODF external equalizer.
E Valves with Chatleff fittings are available only with the 1/8” OD x 24” long tube with flare and nut external equalizer.
CATALOG 301 — Page 9
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A, 410A, 507
Type Q and BQ
The Series Q and BQ are replaceable cartridge style thermostatic
expansion valves, available in both conventional (Type Q) and
balanced port (Type BQ) configurations. These valves can be
supplied as a complete valve or as three component parts, body,
cartridge, and thermostatic element. They are designed for small
refrigeration systems, including refrigerated cases, coolers and
freezers, and are also well suited for air conditioning and heat pump
duty.
Strainer
U.S. Patent
No. 5,232,015
U.S. Patent
No. 5,238,219
R-134a
R-409A
R-410A
SIZE
CARTRIDGE
CODE
COLOR CODE
SERIES Q
CARTRIDGE
R-404A
R-507
0.88
2.63
3.5
5.25
8.75
10.5
17.5
0.44
0.88
1.75
3.5
5.25
7
10.5
0.44
0.88
1.75
3.5
5.25
7
10.5
0.44
0.88
1.75
3.5
5.25
7
10.5
—
—
—
—
—
—
—
0
1
2
3
4
5
6
QC-0
QC-1
QC-2
QC-3
QC-4
QC-5
QC-6
Red
Yellow
Green
Blue
Pink
Black
White
SERIES BQ
NOMINAL CAPACITY (kW)
R-22
R-407C
1.16
2.35
5.25
10.5
19.25
0.7
1.16
3.5
6.13
10.5
0.7
1.16
3.5
6.13
10.5
0.7
1.16
3.5
6.13
10.5
1.17
2.64
6.15
12.3
21.1
AAA
AA
A
B
C
BQC-AAA
BQC-AA
BQC-A
BQC-B
BQC-C
Red
Yellow
Blue
Pink
White
Q valve not suitable for R-410A. BQ valve cartridges are available with 15% bleed port.
Q – Valve Nomenclature/Ordering Instructions
QE
–
O
(1/3T) –
V
C
–
3/8”
x
1/2”
x
1/4
x
5’
Valve Type
Q, EQ, SQ =
Internally
Equalized
Cartridge
Size
QE, EQE, SQE
= Externally
Equalized
Nominal
Capacity
(Tons)
Refrigerant
Code
Thermostatic
Charge
Inlet
Connection
Size
Outlet
Connection
Size
External
Equalizer
Connection
Size
BQ – Valve Nomenclature/Ordering Instructions
BQE
– AAA –
V
C
–
3/8”
x
1/2”
x
1/4
x
5’
Valve Type
BQ, EBQ,
SBQ =
Internally
Equalized
BQE, EBQE,
SBQE =
Externally
Equalized
Cartridge
Size
Refrigerant
Code
Thermostatic
Charge
Inlet
Connection
Size
Outlet
Connection
Size
External
Equalizer
Connection
Size
Capillary
Tubing
Length
Inches
or Feet
Capillary
Tubing
Length
Inches
or Feet
Page 10 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
Selecting Body Type
Q/BQ
EQ/EBQ
SQ/SBQ
SAE
Internally
Equalized
ODF
Internally
Equalized
QE/BQE
ODF
Internally
Equalized
EQE/EBQE
SQE/SBQE
Replaceable
Strainer
•U.S. Patent
No. 5,232,015
•P/N 3427-000
SAE
Externally
Equalized
ODF
Externally
Equalized
ODF
Externally
Equalized
U.S. Patent
No. 5,238,219
Q/BQ & QE/BQE
Options
EQ &EBQ
Options
EQE & EBQE
Options
SQ/SBQ & SQE/SBQE
Options
Inlet x Outlet
Inlet x Outlet
Inlet x Outlet
Inlet x Outlet
1/4 x 3/8 SAE, 90° Angle Inlet
1/4 x 1/2 SAE, 90° Angle Inlet
3/8 x 1/2 SAE, 90° Angle Inlet
3/8 x 1/2 ODF, Straight Thru
3/8 x 1/2 ODF, 90° Angle Inlet
3/8 x 1/2 ODF, Straight Thru
3/8 x 5/8 ODF, Straight Thru
1/2 x 5/8 ODF, Straight Thru
1/2 x 7/8 ODF, Straight Thru
3/8 x 1/2 ODF, 90° Angle Inlet
3/8 x 1/2 SAE, 90° Angle Inlet
Selecting The Element
Abbreviation
for “Kit”
–
43
–
Element Size
Number
V
C
*Refrigerant
Code
Thermostatic
Charge
Bulb
R-22
KT-43-VC
CO • WASHING
LVE
TO
VA
N,
AN
M
RL MADE IN
U.S. of A. O
O
KT
Capillary Tube Length
Standard = 60 inches
(1.5 meters)
43
VC
DATE
4499
Date Code Label
(by week and year of manufacture)
SP
Element Label
See page 3 for thermostatic charges available. BQ valves for R-410A, use KT-45 element.
Selecting The Cartridge – See table on previous page for cartridge codes.
Q Valve Cartridge Service Kit – Part No. 184000
AAA - Red
Qty. 2
AA - Yellow
Qty. 4
Oil Bottle
BQ Cartridge
Tool
No. 6 - White
Qty. 3
S
PO
BQ
RL A
B - Pink
Qty. 1
B - Pink
Qty. 2
Oil Bottle
C
6
A - Blue
Qty. 4
B
No. 5 - Black
Qty. 3
No. 4 - Pink
Qty. 3
N
5
No. 3 - Blue
Qty. 5
4
B
4 mm Allen
Wrench
No. 2 - Green
Qty. 5
3
A
No. 1 - Yellow
Qty. 5
2
AA
No. 0 - Red
Qty. 3
1
AAA
0
BQ Valve Cartridge Service Kit – Part No. 184007
C - White
Qty. 2
CATALOG 301 — Page 11
THERMOSTATIC EXPANSION VALVES
Type Q, QE, BQ, & BQE
Dimensions – Connections
49 mm
FITTING SIZE
Inches
1/4 SAE, 90° Angle
3/8 SAE, 90° Angle
3/8 SAE
1/2 SAE
mm
B
—
—
41
46
A
30
34
—
—
C
37
27
—
—
Top View
100 mm
1/4 SAE
Removable
Strainer
P/N 3008-000
64 mm
C
60°
51 mm
3/8 SAE Inlet
Strainer
P/N 1538-000
A
39 mm
B
Dimensions – Connections
Type EQ, EQE, EBQ, & EBQE
49 mm
FITTING SIZE
Inches
3/8
1/2
5/8
7/8
64 mm
B
—
63
63
61
60°
Top View
3/8 ODF
Insert Strainer
P/N 877-003
100 mm
mm
A
64
61
—
—
I/2 ODF
Insert Strainer
P/N 877-004
(EBQE Only)
51 mm
47 mm
A
View of 90°
elbow inlet
B
Type SQ, SQE, SBQ, & SBQE
49 mm
64 mm
Removable Strainer
P/N 3427-000
47 mm
100 mm
Top View
64 mm
60°
51 mm
47 mm
35 mm
63 mm
Series Q & BQ Bulb Sizes – mm
STANDARD CHARGES
C
Z & ZP
CP
VGA
REFRIGERANT
22
134a
13 OD x 76
—
404A
13OD x 76
13 OD x 76
19 OD x 51
507
13 OD x 76
—
Page 12 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 507
Type S
58.5 mm
Standard Cap Tube Length 60 inches
(1.5 m)
42 mm
Sporlan Type S valve is a brass bar body,
externally adjustable valve with ODF solder
connections. The thermostatic element is
replaceable, and the inlet connection has a
permanent 12 mesh strainer. This valve is
designed for both air conditioning and refrigeration applications.
Dimensions – Connections
VALVE
TYPE
S
54 mm
90 mm
Diameter
of Type X
Charge
Diaphragm
Case is 92 mm
mm
FITTING SIZE
Inches
3/8 ODF
1/2 ODF
5/8 ODF
7/8 ODF
1-1/8 ODF
A
34
33
38
—
—
B
—
34.5
40
54
55.5
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
X
CP Series
VGA
B
A
30°
22
13 OD x 89
19 OD x 102
19 OD x 51
36 mm
ODF Solder
REFRIGERANT
134a
404A
507
13 OD x 89
–
13 OD x 89
–
19 OD x 102
13 OD x 89
–
–
–
–
1/4” ODF
External
Equalizer
Connection
Top View
134a (J)
409A (F)
404A (S)
507 (P)
SNE-2
SNE-3
SNE-4
SNE-5
SNE-8
SNE-10
SNE-15
SJE-2
SJE-2-1/2
SJE-3
SJE-5
SJE-6
SJE-10
SSE-2
SSE-3
SSE-4
SSE-6
SSE-7
SSE-10
SPE-2
SPE-3
SPE-4
SPE-6
SPE-7
SPE-10
7.0
11
14
18
28
35
56.5
7.0
8.8
11
18
21
35
7.0
11
14
21
25
35
7.0
11
14
21
25
35
STANDARD
TUBING LENGTH
m
SN-2
SN-3
SN-4
SN-5
—
—
—
SJ-2
SJ-2-1/2
SJ-3
—
—
—
SS-2
SS-3
SS-4
—
—
—
SP-2
SP-3
SP-4
—
—
—
1.5
INLET
OUTLET
3/8 or 1/2
5/8, 7/8 or 1-1/8
1/2
5/8, 7/8 or 1-1/8
5/8
7/8 or 1-1/8
7/8
3/8 or 1/2
1-1/8
5/8, 7/8 or 1-1/8
1/2
5/8, 7/8 or 1-1/8
5/8
7/8 or 1-1/8
7/8
3/8 or 1/2
1-1/8
5/8, 7/8 or 1-1/8
1/2
5/8, 7/8 or 1-1/8
5/8
7/8 or 1-1/8
7/8
3/8 or 1/2
1-1/8
5/8, 7/8 or 1-1/8
1/2
5/8, 7/8 or 1-1/8
5/8
7/8 or 1-1/8
7/8
1-1/8
QValves listed in this column NOT AVAILABLE with MOP Type air conditioning charges.
WODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing.
Note: S Valves not available for R-410A.
SHIPPING
WEIGHT - kg
22 (V)
EXTERNAL
EQUALIZER
CONNECTIONS - Inches
W ODF Solder
Blue figures are standard
and will be furnished unless
otherwise specified.
NET
WEIGHT - kg
407C (N)
INTERNAL
EQUALIZER
Q
THERMOSTATIC
CHARGES
AVAILABLE
REFRIGERANT
(Sporlan Code)
Refer to Recommended
Thermostatic Charges on page 3
VALVE TYPE
NOMINAL
CAPACITY
kW of
Refrigeration
Specifications – Element Size No. 83, Knife Edge Joint
0.9
1.4
CATALOG 301 — Page 13
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A, 507
Type EBS
58.5 mm
Standard Cap Tube Length 60 inches
(1.5 m)
Sporlan Type EBS valve is a brass bar
body valve having the same physical size
as the Type S valve except the Type EBS
features a balanced port construction and
extended ODF connections. The thermostatic element is replaceable. The balanced
port construction makes this valve ideally
suited for refrigeration and air conditioning applications which
operate over widely varying conditions.
46 mm
C
C
85 mm
87 mm (EBSVE-20 only)
70 mm
(EBSVE-20 only) 72 mm
Dimensions – Connections
VALVE
TYPE
EBS
FITTING SIZE
Inches
3/8 ODF
1/2 ODF
5/8 ODF
7/8 ODF
1-1/8 ODF
A
62
62
62
—
—
mm
B
—
—
64
64
77
C
9
13
19
20.5
24.5
1/4” ODF
External
Equalizer
Connection
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
CP Series
VGA
22
13 OD x 89
19 OD x 51
B
A
REFRIGERANT
134a
404A
507
13 OD x 89
–
13 OD x 89
13 OD x 89
–
–
–
–
30°
Top View
134a (J)
409A (F)
404A (S)
507 (P)
STANDARD
TUBING LENGTH
m
INLET
OUTLET
EBSNE-8
28
1/2 or 5/8
7/8 or 1-1/8
EBSNE-11
39
1/2, 5/8 or 7/8
7/8, 1-1/8 or 1-3/8
EBSNE-15
53
5/8 or 7/8
7/8, 1-1/8 or 1-3/8
7/8
1-1/8 or 1-3/8
EBSNE-20
70
EBSJE-5
18
EBSJE-7
25
EBSJE-9
32
EBSJE-12
42
EBSSE-6
21
EBSSE-7-1/2
26
EBSSE-10
35
EBSSE-13
46
EBSPE-6
21
EBSPE-7-1/2
1.5
1/2 or 5/8
7/8 or 1-1/8
1/2, 5/8 or 7/8
7/8, 1-1/8 or 1-3/8
5/8 or 7/8
7/8, 1-1/8 or 1-3/8
7/8
1-1/8 or 1-3/8
1/2 or 5/8
7/8 or 1-1/8
1/2, 5/8 or 7/8
7/8, 1-1/8 or 1-3/8
5/8 or 7/8
7/8, 1-1/8 or 1-3/8
7/8
1-1/8 or 1-3/8
1/2 or 5/8
7/8 or 1-1/8
26
1/2, 5/8 or 7/8
7/8, 1-1/8 or 1-3/8
EBSPE-10
35
5/8 or 7/8
7/8, 1-1/8 or 1-3/8
EBSPE-13
46
7/8
1-1/8 or 1-3/8
EXTERNAL
EQUALIZER
1/4
Pointed
Toward
Bottom Cap
or
Parallel to Outlet
Connection
QODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing.
* X charge not available.
Note: Not suitable for bi-directional flow control.
SHIPPING
WEIGHT - kg
22 (V)
CONNECTIONS - Inches
Q Extended ODF Solder
Blue figures are standard and will be
furnished unless otherwise specified.
NET
WEIGHT - kg
407C (N)
EXTERNAL
EQUALIZER
*Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
THERMOSTATIC
CHARGES
AVAILABLE
VALVE TYPE
NOMINAL
CAPACITY
kW of
Refrigeration
Specifications – Element Size No. 83, Knife Edge Joint
0.9
1.4
Page 14 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A, 410A, 507
Type O
This valve type has two body styles: a small body which provides
capacities up to 133 kW R-407C, and a large body which extends
capacities to 315 kW R-407C.
Sporlan Type O valve is a brass bar body, externally adjustable
valve with ODF solder connections. The thermostatic element is
replaceable, and the inlet connection has a permanent 12 mesh
strainer. This valve type features a balanced port construction, and
it is designed for both air conditioning and refrigeration applications. A synthetic seating surface provides tight shut-off during
system off periods.
The valve can also be ordered as a bidirectional valve, allowing control of
flow in both directions for use on heat
pump applications.
Standard Cap Tube Length 60 inches
(1.5 m)
U.S. Patent
No. 3,742,722
409A (F)
404A (S)
507 (P)
407C (N)
22 (V)
410A (Z)
INLET
OUTLET
1-3/8
1-1/8
33
83
33
83
33-8
33
0.9
1.4
1.8
2.3
0.9
1.4
1.8
2.3
0.9
1.4
1.8
2.3
0.9
1.4
1.8
2.3
1-1/8
7/8
83
SHIPPING
WEIGHT - kg
134a (J)
CONNECTIONS - Inches
2 ODF Solder
Blue figures are standard and will
be furnished unless otherwise
specified.
NET
WEIGHT - kg
42
56
81
112
133
140
42
74
105
123
133
158
70
105
133
140
193
215
315
70
84
116
175
210
STANDARD
TUBING LENGTH
m
OJE-12
OJE-16
OJE-23
OJE-32
OJE-38
OJE-40
OSE-12
OSE-21
OSE-30
OSE-35
OSE-38
OSE-45
ONE-20
ONE-30
ONE-38
ONE-40
ONE-55
ONE-70
ONE-90
OZE-20
OZE-25
OZE-35
OZE-50
OZE-60
THERMOSTATIC
CHARGES
AVAILABLE
Q EXTERNAL
EQUALIZER
1-3/8 or 1-5/8
1-1/8
7/8
*Refer to Recommended
Thermostatic Charges on page 3
REFRIGERANT
(Sporlan Code)
NOMINAL
CAPACITY
kW of
Refrigeration
VALVE TYPE
THERMOSTATIC
ELEMENT
SIZE NO.
Specifications – Element Size No. 83, No. 33, No. 85 (R-410A), and No. 85-3 (R-410A), Knife Edge Joint
1-3/8
1-1/8
1-3/8 or 1-5/8
1.5
1-1/8
7/8
1-3/8
1-1/8
1-3/8 or 1-5/8
63-3
85
85-3
7/8
1-1/8
1-1/8
1-3/8
QStandard External Equalizer Connection 1/4” ODF Solder, 1/4” SAE flare connection available on request.
2ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 5/8” ODF will receive 5/8” OD tubing.
* X charge not available.
O – Valve Nomenclature/Ordering Instructions
O
Valve
Type
V
Refrigerant
Code
E
External
Equalizer
–
B
Optional
Bi-Directional
Feature
–
20
Nominal
Capacity
–
GA
Thermostatic
Charge
x
7/8”
Inlet
Connection
Size
x
1-3/8”
Outlet
Connection
Size
x
1/4”
External
Equalizer
Connection
Size
x
5’
Capillary
Tubing
Length
Inches
or Feet
CATALOG 301 — Page 15
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 410A, 507
Type O with Number 83 or 85 Element
59 mm
1/4” ODF External
Equalizer
Connection
36 mm
43 mm
62 mm
Top View
C
Dimensions – Connections
VALVE
TYPE
O
FITTING SIZE
Inches
7/8 ODF
1-1/8 ODF
1-3/8 ODF
A
53
56
—
C
mm
B
—
57
61
C
19
25
25
105 mm
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
CP Series
VGA
ZGA
A
22
13 OD x 89
19 OD x 51
—
REFRIGERANT
404A
134a
13 OD x 89
—
13 OD x 89
—
—
13 OD x 89
—
—
410A
—
—
—
—
19 OD x 51
B
507
13 OD x 89
13 OD x 89
—
—
—
Type O with Number 33 or 85-3 Element
70 mm R-22 35 Element
59 mm R-410A 85-3 Element
59 mm
1/4” ODF External
Equalizer
Connection
40 mm
49 mm
74 mm
Top View
C
C
140 mm
Dimensions – Connections
VALVE
TYPE
O
FITTING SIZE
Inches
1-1/8 ODF
1-3/8 ODF
1-5/8 ODF
A
68
—
—
mm
B
—
76
79
C
23
25
28
A
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
CP Series
VGA
ZGA
22
19OD x 102
19OD x 102
19 OD x 102
—
134a
13 OD x 127
—
19 OD x 102
—
—
REFRIGERANT
404A
19 OD x 102
19 OD x 102
—
—
410A
—
—
—
—
19 OD x 51
507
19 OD x 102
19 OD x 102
—
—
—
B
Page 16 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A, 507
Type H
70 mm
Brass bar body, externally adjustable valve
with flange connections. Inlet flange bushing
has a permanent 16 mesh strainer. The FPT
flange connection requires the K-1178 adapter
kit. This valve provides the smallest capacity
TEVs with flange connections and it is suitable for both air conditioning and refrigeration applications.
52 mm
Dimensions – Connections
VALVE
TYPE
H
114 mm
mm
SOLDERING
BUSHING
1/2
5/8
7/8
1-1/8
A
51
51
51
52
B
B
B
22
22
22
24
A
A
Diameter
of Type X
Charge
Diaphragm
Case Is 92 mm
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
X
CP Series
VGA
22
19 OD x 102
19 OD x 102
19 OD x 102
19 OD x 102
REFRIGERANT
134a
404A
507
13 OD x 127
19 OD x 102
—
19 OD x 102
—
19 OD x 102
19 OD x 102
—
—
—
—
REFRIGERANT
(Sporlan Code)
134a (J)
409A (F)
404A (S)
507 (P)
407C (N)
22 (V)
WINTERNAL
EQUALIZER
HJ-1-1/2
HJ-3
HJ-4
HJ-5
—
—
HS-1-1/2
HS-3
HS-4
—
—
—
HN-2-1/2
HN-5-1/2
—
—
—
—
EEXTERNAL
EQUALIZER
HJE-1-1/2
HJE-3
HJE-4
HJE-5
HJE-8
HJE-12
HSE-1-1/2
HSE-3
HSE-4
HSE-6-1/2
HSE-9
HSE-12
HVE-2-1/2
HVE-5-1/2
HVE-7
HVE-11
HVE-16
HVE-20
Refer to Recommended
Thermostatic Charges on Page 3
TYPE & CAPACITY
THERMOSTATIC
CHARGES
AVAILABLE
Specifications – Element Size No. 33, Gasket Joint,
Standard Tubing Length 1.5 Meters5
Flange Ring Size – 1-1/4” OD x 1” ID.
QSTANDARD
CONNECTIONS Inches
RODF SOLDER
FLANGE
Blue figures are standard
and will be furnished unless
otherwise specified.
INLET
1/2
OUTLET
5/8
5/8
7/8
7/8
1/2
1-1/8
5/8
5/8
7/8
7/8
1/2
1-1/8
5/8
5/8
7/8
7/8
1-1/8
Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order.
W Valves listed in this column NOT AVAILABLE with MOP Type air conditioning charges.
E Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request.
R ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing.
5 Tubing lengths other than standard available upon special order at an additional cost.
NOTE: The H valve is not available for R-410A.
External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors.
CATALOG 301 — Page 17
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A, 507
Type M
92 mm
Cast bronze body, externally adjustable
valve with flange connections. Inlet has a
12 mesh strainer. This valve type provides
valve capacities greater than the Type H
and it is suitable for air conditioning and
refrigeration applications. Flanges for the
Type M valve are interchangeable with the
Type V valve.
71 mm
Dimensions – Connections
VALVE
TYPE
H
SOLDERING
BUSHING
7/8
1-1/8
1-3/8
1-5/8
B
mm
A
60
70
70
82
125 mm
B
22
24
24
31
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
X
CP Series
VGA
22
22 OD x 152
22 OD x 152
19 OD x 102
B
A
REFRIGERANT
134a
404A
507
22 OD x 152
—
22 OD x 152
—
22 OD x 152
19 OD x 102
—
—
—
—
Diameter
of Type X
Charge
Diaphragm
Case Is 121 mm
A
Specifications – Element Size No. 63, Gasket Joint,
TYPE & CAPACITY
134a (J)
409A (F)
2EXTERNAL
EQUALIZER
MJE-15
MJE-20
MJE-25
MSE-15
404A (S)
507 (P)
MSE-20
MSE-25
MSE-30
MNE-21
407C (N)
22 (V)
MNE-26
MNE-34
MNE-42
Refer to Recommended
Thermostatic Charges on Page 3
REFRIGERANT
(Sporlan Code)
THERMOSTATIC
CHARGES
AVAILABLE
Standard Tubing Length 1.5 Meters4
Flange Ring Size – 1-3/4” OD x 1-1/4” ID.
QSTANDARD
CONNECTIONS Inches
3ODF SOLDER
FLANGE
Blue figures are standard
and will be furnished unless
otherwise specified.
INLET
OUTLET
7/8
1-1/8
7/8
1-1/8
1-1/8
7/8
1-1/8
Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order.
2 Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request.
3 ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing.
4 Tubing lengths other than standard available upon special order at an additional cost.
NOTE: The M valve is not available for R-410A.
External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors.
Page 18 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
22, 134a, 404A, 407C, 409A, 507
Type V
92 mm
Cast bronze body, externally adjustable
valve with flange connections. Inlet has a
12 mesh strainer. This valve type features a
dual port semi-balanced design. This valve
type provides valve capacities greater than
the Type M and is suitable for air conditioning and refrigeration applications. Flanges
for the Type V are interchangeable with the
Type M.
106 mm
B
B
Dimensions – Connections
VALVE
TYPE
V
SOLDERING
BUSHING
7/8
1-1/8
1-3/8
1-5/8
mm
A
60
70
70
82
122 mm
B
22
24
24
31
A
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
X
CP Series
VGA
22
22 OD x 152
22 OD x 152
19 OD x 102
A
REFRIGERANT
134a
404A
507
22 OD x 152
—
22 OD x 152
—
22 OD x 152
19 OD x 102
—
—
—
—
Specifications – Element Size No. 63,
REFRIGERANT
(Sporlan Code)
134a (J)
409A (F)
404A (S)
507 (P)
407C (N)
22 (V)
2EXTERNAL
EQUALIZER
VJE-35
VJE-45
VJE-55
VSE-38
VSE-50
VSE-70
VNE-52
VNE-70
VNE-100
Refer to Recommended
Thermostatic Charges on Page 3
TYPE & CAPACITY
THERMOSTATIC
CHARGE
AVAILABLE
Gasket Joint, Standard Tubing Length 1.5 Meters4
Flange Ring Size – 1-3/4” OD x 1-1/2” ID.
QSTANDARD
CONNECTION Inches
3ODF SOLDER
FLANGE
Blue figures are standard
and will be furnished unless
otherwise specified.
INLET
OUTLET
1-3/8
1-3/8
Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order.
2 Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request.
3 ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing.
4 Tubing lengths other than standard available upon special order at an additional cost.
NOTE: The V valve is not available for R-410A.
External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors.
Diameter
of Type X
Charge
Diaphragm
Case Is 121 mm
CATALOG 301 — Page 19
THERMOSTATIC EXPANSION VALVES
22, 134a, 407C, 409A
Type W
*
Cast bronze body, externally adjustable valve with flange connections. Inlet has a 12 mesh strainer. This valve type features a dual
port semi-balanced design and it is primarily for large capacity
chillers. This valve type provides the largest valve capacities available for flange connection TEVs.
116 mm
Dimensions – Connections
VALVE
TYPE
FITTING SIZE
W
1-1/8
1-3/8
1-5/8
2-1/8
D
mm
A
28
35
41
54
B
32
39
45
62
C
27
33
38
49
D
23
25
28
34
E
40
41
44
39
F
78
80
83
83
155 mm
Bulb Sizes
STANDARD
CHARGES
C
Z & ZP Series
X
CP Series
VGA
G
REFRIGERANT
ELEMENT SIZE
22
NUMBER
63
7
*Diameter of
Diaphragm
Case is 92 mm
for Small W
and 121 mm for
Large W
134a
22 OD x 152
22 OD x 152
22 OD x 152
19 OD x 102
19 OD x 102
19 OD x 102
F
F
86 mm
—
—
—
—
B
A
E
64 mm
19
mm
3 mm
13 mm - Diameter
Bolt Holes
C
52 mm
71 mm
Specifications – Element Size No. 63, Small Capacity No. 7 Large Capacity – Gasket
134a (J)
409A (F)
407C (N)
22 (V)
2EXTERNAL
EQUALIZER
THERMOSTATIC
CHARGES
AVAILABLE
REFRIGERANT
(Sporlan Code)
ELEMENT SIZE
NUMBER
Joint, Standard Tubing Length 3 Meters5
Flange Ring Size – 2-3/4” OD x 2-3/16” ID.
TYPE &
CAPACITY
WJE-80
63
4
WJE-110
7
G only
WNE-135
63
4
WNE-180
7
G only
A B
QSTANDARD
CONNECTIONS Inches
3ODF SOLDER
FLANGE
Blue figures are standard
and will be furnished unless
otherwise specified.
INLET
OUTLET
1-5/8
2-1/8
Q Connections shown are most readily available. Connections shown in Bulletin 10-10 are also available on special order.
2 Standard External Equalizer Connection 1/4” SAE Flare, 1/4” ODF Solder connection available on request.
3 ODF Solder indicates a female connection on the valve of proper diameter to receive copper tubing of corresponding OD size. Thus 1/2” ODF will receive 1/2” OD tubing.
4 Refer to Recommended Thermostatic Charges, Page 3.
5 Tubing lengths other than standard available upon special order at an additional cost.
NOTE: The W valve is not available for R-410A.
External Equalizer Connection is required whenever valves are used with Sporlan Refrigerant Distributors.
E
Page 20 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
134a, 409A
Air Conditioning, Heat Pump and Commercial Refrigeration Applications
VALVE TYPES
NOMINAL
CAPACITY
kW
5°
FB
FB
FB
FB
FB
FB-S
FB-S
S
S
S
S
H
H
H
H
H
H
M
M
M
0.44
0.88
1.8
3.5
5.3
7.0
8.8
11
18
21
35
5.3
11
14
18
28
42
53
70
88
0.76
1.51
2.85
4.80
5.97
8.17
10.2
12.3
20.6
24.7
38.2
6.54
12.3
16.3
20.4
30.6
47.8
63.3
81.7
102
REFRIGERANT
134a
409A
RECOMMENDED THERMOSTATIC CHARGE
JC, JCP60
FC, FCP60
EVAPORATOR TEMPERATURE °C
-5°
-15°
5°
-5°
0.89
1.77
3.35
5.64
7.01
8.73
10.9
13.1
18.8
22.5
36.3
6.99
13.1
17.5
21.8
32.8
51.1
67.7
87.3
109
0.80
1.59
3.01
5.07
6.30
8.01
10.0
12.0
15.6
18.7
31.1
6.40
11.3
15.1
18.8
28.2
44.0
56.7
73.2
91.5
0.76
1.52
2.87
4.83
6.01
8.23
10.3
12.3
20.7
24.9
38.4
6.58
12.3
16.4
20.6
30.8
48.1
63.7
82.3
103
-15°
0.90
1.80
3.39
5.71
7.10
8.84
11.0
13.3
19.0
22.8
36.7
7.07
13.3
17.7
22.1
33.1
51.7
68.5
88.4
110
0.81
1.62
3.06
5.15
6.41
8.15
10.2
12.2
15.8
19.0
31.7
6.52
11.5
15.3
19.1
28.7
44.8
57.7
74.5
93.1
2.90
5.07
6.66
9.27
12.2
14.5
17.4
21.0
28.9
36.7
51.7
68.5
109
152
190
155
199
243
376
—
2.62
4.58
6.02
8.37
11.0
13.1
14.6
18.1
25.0
30.0
42.3
60.4
94.2
131
164
128
164
201
296
—
BALANCED PORT THERMOSTATIC EXPANSION VALVES
R
R
R
R
R
R
R
EBS
EBS
EBS
EBS-O
O
O
O
O
V
V
V
W
W
1.8
3.5
5.3
7.0
8.8
11
14
18
25
32
42
56
81
110
140
120
160
190
280
390
VALVE TYPE
CARTRIDGE
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
0
1
2
3
4
5
6
VALVE TYPE
CARTRIDGE
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
AAA
AA
A
B
C
2.44
4.27
5.61
7.80
10.2
12.2
14.6
20.8
28.7
38.1
47.8
63.3
96.6
130
163
143
184
225
347
486
2.86
5.01
6.58
9.16
12.0
14.3
17.2
20.7
28.6
36.3
51.1
67.7
108
150
188
153
197
240
371
—
2.57
4.50
5.91
8.23
10.8
12.9
14.3
17.8
24.6
29.5
41.5
59.4
92.6
129
161
126
162
198
291
—
2.45
4.29
5.64
7.85
10.3
12.3
14.7
21.0
28.9
38.4
48.1
63.7
94.2
131
164
144
185
226
350
490
CONVENTIONAL CARTRIDGE THERMOSTATIC EXPANSION VALVES
0.59
0.88
1.8
3.5
5.3
7.0
8.8
0.82
1.84
2.65
4.08
5.72
8.17
11.0
0.87
1.97
2.84
4.37
6.11
8.73
11.8
0.80
1.80
2.60
4.00
5.60
8.01
10.8
0.82
1.85
2.67
4.11
5.76
8.23
11.1
0.88
1.99
2.87
4.42
6.19
8.84
11.9
0.82
1.83
2.65
4.07
5.70
8.15
11.0
BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES
0.70
1.2
3.5
7.0
11
0.85
1.84
4.08
6.94
12.3
LIQUID TEMPERATURE ENTERING TEV °C
REFRIGERANT -10° 0°
10° 20° 30° 40° 50° 60°
CORRECTION FACTOR, CF LIQUID TEMPERATURE
134a
1.64 1.52 1.39 1.26 1.13 1.00 0.87 0.73
409A
1.51 1.41 1.31 1.21 1.11 1.00 0.89 0.78
These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they
may be used for any evaporator temperature from -15°C to 5°C since the variation
in the actual factors across this range is insignificant.
0.99
1.97
4.37
7.42
13.1
0.95
1.80
4.00
6.80
12.0
EVAPORATOR
TEMPERATURE
°C
5°
-5° & -15°
0.85
1.85
4.11
6.99
12.3
1.00
1.99
4.42
7.51
13.3
0.97
1.83
4.07
6.92
12.2
PRESSURE DROP ACROSS TEV (bar)
2
4
6
8
10
12
14
16
CORRECTION FACTOR, CF PRESSURE DROP
0.71 1.00 1.22 1.41 1.58 1.73 1.87 2.00
0.58 0.82 1.00 1.15 1.29 1.41 1.53 1.63
TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example:
Actual capacity of a nominal 1-1/2 ton R-134a Type FB valve at -5°C evaporator, 8 bar pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 7.01 (from
rating chart) x 1.13 (CF liquid temperature) x 1.15 (CF pressure drop) = 9.11 kW.
CATALOG 301 — Page 21
THERMOSTATIC EXPANSION VALVES
22, 407C
Air Conditioning, Heat Pump and Commercial Refrigeration Applications
REFRIGERANT
22
407C
RECOMMENDED THERMOSTATIC CHARGE
VC, VCP100, VGA
VZ, VZP40
NC, NCP100, NGA
EVAPORATOR TEMPERATURE °C
5°
-5°
-15°
-20°
-30°
-40°
5°
-5°
-15°
VALVE TYPES
NOMINAL
CAPACITY
FB
FB
FB
FB
FB-S
FB-S
FB-S
S
S
S
S
H
H
H
H
H
H
M
M
M
M
0.88
1.8
3.5
5.3
7.0
11
14
18
28
35
53
8.8
19
25
39
56
70
74
91
120
150
R-RC
R-RC
R-RC
R-RC
R-RC
R-RC
R-RC
R
R
R
EBS
EBS
EBS
EBS-O
O
O
O
O
O
O
V
V
V
W
W
3.5
5.3
7.0
11
14
18
21
28
35
44
28
39
53
70
110
130
140
190
250
320
180
250
350
470
630
3.21
5.62
7.39
10.3
13.5
16.1
19.3
25.7
33.5
38.9
27.4
37.0
49.7
71.9
98.2
122
129
177
235
289
167
235
321
459
607
1.2
2.6
3.5
5.3
8.8
12
18
1.12
2.41
3.21
4.82
8.03
11.2
15.4
1.2
2.3
5.3
11
18
1.12
2.41
5.14
8.99
16.7
kW
1.00
1.99
3.76
6.01
6.87
10.9
13.4
16.7
25.7
32.1
49.8
8.04
18.0
22.5
33.8
48.9
71.4
69.0
85.1
109
135
1.12
2.25
4.24
6.78
7.75
12.3
15.1
18.8
29.0
36.2
56.2
8.90
19.9
24.9
37.4
54.1
79.1
77.9
96.0
123
152
1.03
2.06
3.88
6.21
7.10
11.3
13.9
17.0
24.6
30.8
47.7
8.12
18.2
22.7
34.1
49.4
72.1
75.3
92.9
119
147
1.04
2.08
3.69
5.68
6.78
10.6
13.1
16.4
23.4
29.3
46.1
8.12
18.0
21.7
31.6
45.6
68.9
74.8
96.7
120
151
0.80
1.61
2.52
3.57
4.68
7.17
8.77
11.8
15.9
19.8
31.2
5.09
11.1
12.5
17.0
24.3
39.5
53.6
75.7
89.1
107
0.63
1.25
1.96
2.78
3.65
5.59
6.84
9.22
12.3
15.3
24.9
4.28
9.34
10.5
14.3
20.4
33.2
45.2
63.9
75.2
86.2
0.91
1.81
3.42
5.47
6.26
9.94
12.2
15.2
23.4
29.2
45.3
7.32
16.4
20.5
30.7
44.5
65.0
62.9
77.5
99.4
123
1.01
2.02
3.80
6.08
6.96
11.1
13.6
16.9
26.0
32.5
50.4
7.99
17.9
22.4
33.5
48.6
70.9
69.9
86.1
111
137
0.91
1.82
3.43
5.48
6.27
9.97
12.3
15.0
21.8
27.2
42.2
7.17
16.1
20.1
30.1
43.6
63.7
66.5
82.0
105
130
1.96
2.78
3.65
5.25
6.84
7.83
8.00
9.27
—
—
13.0
17.5
23.4
29.6
49.1
60.9
74.6
83.0
90.4
111
101
138
178
255
—
2.92
5.12
6.72
9.35
12.3
14.6
17.5
23.4
30.5
35.4
24.9
33.7
45.3
65.5
89.4
111
118
161
214
263
152
214
292
418
553
3.25
5.69
7.48
10.4
13.7
16.3
19.5
26.0
33.9
39.3
26.5
35.8
48.8
68.8
94.9
118
130
177
235
290
168
235
322
461
—
2.93
5.13
6.74
9.38
12.3
14.7
16.3
23.4
30.6
35.5
22.4
30.3
38.6
53.7
81.1
97.3
102
139
184
226
159
224
306
438
—
1.14
2.44
3.25
4.88
8.13
11.4
15.6
1.01
2.16
2.88
4.33
7.21
10.1
13.8
1.14
2.44
5.20
9.10
16.9
1.01
2.16
4.61
8.08
15.0
BALANCED PORT THERMOSTATIC EXPANSION VALVES
VALVE TYPE
CARTRIDGE
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
0
1
2
3
4
5
6
VALVE TYPE
CARTRIDGE
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
AAA
AA
A
B
C
3.62
6.34
8.33
11.6
15.2
18.1
21.7
29.0
37.8
43.8
29.5
39.9
54.4
76.7
106
132
145
198
262
323
187
262
359
514
—
3.32
5.81
7.63
10.6
13.9
16.6
18.5
26.5
34.6
40.1
25.4
34.3
43.7
60.8
91.8
110
115
157
209
255
180
253
347
496
—
3.32
5.42
7.12
10.0
13.1
15.4
16.8
23.2
—
—
24.5
33.1
42.0
58.3
84.8
102
111
150
198
243
190
265
355
507
—
2.52
3.57
4.68
6.73
8.77
10.0
10.4
12.0
—
—
16.8
22.7
29.1
40.2
56.5
70.3
86.1
98.2
111
137
121
167
214
307
—
CONVENTIONAL CARTRIDGE THERMOSTATIC EXPANSION VALVES
1.27
2.72
3.62
5.43
9.06
12.7
17.4
1.14
2.45
3.27
4.90
8.16
11.4
15.7
1.10
2.50
3.27
4.65
8.25
11.4
15.1
0.79
1.99
2.52
3.22
6.43
8.77
10.7
0.62
1.55
1.96
2.51
5.02
6.84
8.33
1.02
2.19
2.92
4.39
7.31
10.2
14.0
BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES
LIQUID TEMPERATURE ENTERING TEV °C
REFRIGERANT -10° 0°
10° 20° 30° 40° 50° 60°
CORRECTION FACTOR, CF LIQUID TEMPERATURE
22
1.52 1.42 1.32 1.21 1.11 1.00 0.89 0.78
407C
1.73 1.59 1.45 1.30 1.15 1.00 0.84 0.67
These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they
may be used for any evaporator temperature from -15°C to 5°C since the variation
in the actual factors across this range is insignificant.
1.27
2.72
5.80
10.1
18.8
1.14
2.45
5.23
9.14
17.0
EVAPORATOR
TEMPERATURE
°C
5°
-5° & -15°
-20° & -30°
-40°
1.10
2.50
5.03
8.95
16.4
0.79
1.99
3.57
6.58
11.8
0.62
1.55
2.78
5.13
9.22
1.02
2.19
4.68
8.19
15.2
PRESSURE DROP ACROSS TEV (bar)
2
4
6
8
10
12
14
16
CORRECTION FACTOR, CF PRESSURE DROP
0.58 0.82 1.00 1.15 1.29 1.41 1.53 1.63
0.50 0.71 0.87 1.00 1.12 1.22 1.32 1.41
0.45 0.63 0.77 0.89 1.00 1.10 1.18 1.26
0.41 0.58 0.71 0.82 0.91 1.00 1.08 1.15
TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example:
Actual capacity of a nominal 1-1/2 ton R-22 Type FB valve at -5°C evaporator, 10 bar pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 6.78 (from
rating chart) x 1.11 (CF liquid temperature) x 1.12 (CF pressure drop) = 8.43 kW.
Page 22 — CATALOG 301
THERMOSTATIC EXPANSION VALVES
404A, 507
Air Conditioning, Heat Pump and Commercial Refrigeration Applications
REFRIGERANT
404A
VALVE TYPES
NOMINAL
CAPACITY
kW
5°
-5°
-15°
RECOMMENDED THERMOSTATIC CHARGE
SZ, SZP
PC
EVAPORATOR TEMPERATURE °C
-20°
-30°
-40°
5°
-5°
-15°
FB
FB
FB
FB
FB
FB-S
FB-S
S
S
S
S
H
H
H
H
H
H
M
M
M
M
0.44
0.88
1.8
3.5
5.3
7.0
11
14
21
25
35
5.3
11
14
23
32
42
53
70
88
110
0.65
1.12
2.25
3.90
4.46
6.43
8.72
12.9
17.8
22.7
32.5
4.84
9.04
12.9
21.0
30.7
42.0
50.8
66.2
82.6
99.6
0.71
1.24
2.47
4.29
4.91
7.01
9.59
14.0
17.1
21.8
31.8
4.85
9.05
12.9
21.0
30.7
42.0
55.8
72.8
90.8
110
0.63
1.10
2.20
3.81
4.36
6.17
8.49
12.1
14.4
18.4
28.4
4.54
7.80
10.7
17.4
25.5
34.9
45.3
57.5
71.7
86.5
0.62
1.12
2.11
3.43
4.12
6.42
7.90
12.3
15.2
19.3
30.3
4.94
8.23
11.3
18.0
24.1
34.9
46.4
58.2
70.9
84.2
R
R
R
R
R
R
R
EBS
EBS
EBS
EBS
O
O
O
O
O
V
V
V
1.8
3.5
5.3
7.0
11
12
14
21
26
35
46
42
74
110
120
160
130
180
250
1.92
3.65
4.80
6.65
8.76
10.4
12.5
18.1
24.5
30.2
43.1
42.0
67.8
97.1
113
145
122
164
225
0.59
0.88
1.8
3.5
5.3
7.0
11
0.64
1.45
2.09
3.22
5.14
6.75
9.00
0.70
1.2
3.5
7.0
11
0.72
1.45
3.21
5.95
9.00
SCP115, SC
0.45
0.86
1.47
2.08
2.78
4.17
5.12
9.45
12.3
15.6
26.2
3.99
6.65
9.31
14.5
16.6
26.6
39.6
49.7
58.3
67.5
0.33
0.65
1.10
1.56
2.09
3.13
3.84
8.15
9.89
12.6
23.5
3.30
5.51
7.71
12.0
13.8
22.0
33.2
41.7
48.9
56.6
0.64
1.10
2.21
3.83
4.39
6.32
8.57
12.6
17.5
22.3
31.9
4.76
8.88
12.7
20.6
30.1
41.2
49.9
65.0
81.1
97.9
507
PZ, PZP
-20°
-30°
-40°
0.70
1.21
2.43
4.21
4.82
6.88
9.41
13.8
16.8
21.4
31.3
4.76
8.88
12.7
20.6
30.1
41.3
54.8
71.4
89.1
108
0.62
1.08
2.16
3.75
4.29
6.06
8.34
11.9
14.2
18.0
27.9
4.46
7.66
10.5
17.1
25.0
34.2
44.5
56.5
70.4
85.0
0.61
1.10
2.07
3.38
4.05
6.44
7.77
12.1
14.9
19.0
29.8
4.86
8.09
11.1
17.7
23.7
34.4
45.6
57.2
69.7
82.8
0.44
0.85
1.45
2.05
2.74
4.11
5.05
9.31
12.1
15.4
25.8
3.93
6.55
9.17
14.3
16.4
26.2
39.0
48.9
57.4
66.5
0.33
0.64
1.09
1.54
2.06
3.09
3.79
8.05
9.77
12.4
23.2
3.26
5.44
7.62
11.8
13.6
21.8
32.8
41.2
48.3
55.9
2.07
3.94
5.18
7.18
9.46
11.3
13.5
18.3
24.8
31.2
45.1
41.3
66.6
104
120
155
127
171
235
1.85
3.51
4.61
6.39
8.41
10.0
11.2
15.4
21.0
24.9
35.3
33.6
50.2
80.3
93.1
120
111
149
207
1.87
3.22
4.22
5.93
7.80
9.17
10.0
15.2
20.2
24.2
34.1
33.7
45.5
71.6
81.2
101
115
158
220
1.45
2.05
2.67
3.86
5.05
5.77
6.05
10.5
13.3
17.6
25.2
26.8
32.1
48.0
52.2
60.1
96.1
137
192
1.09
1.54
2.01
2.90
3.79
4.34
4.50
9.75
12.4
15.3
20.2
23.2
27.8
41.6
45.2
52.1
79.2
113
158
0.69
1.56
2.20
3.00
4.95
6.54
8.51
0.54
1.22
1.60
2.31
3.99
5.32
6.65
0.47
1.06
1.39
2.00
3.45
4.60
5.75
0.80
1.56
3.63
5.60
8.51
0.66
1.22
2.99
4.34
6.65
0.57
1.06
2.58
3.76
5.75
BALANCED PORT THERMOSTATIC EXPANSION VALVES
VALVE TYPE
CARTRIDGE
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
Q-EQ-SQ
0
1
2
3
4
5
6
VALVE TYPE
CARTRIDGE
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
AAA
AA
A
B
C
2.11
4.01
5.28
7.31
9.63
11.5
13.8
18.6
25.3
31.7
45.9
42.0
67.9
106
123
158
130
174
239
1.88
3.57
4.69
6.50
8.56
10.2
11.4
15.7
21.3
25.3
36.0
34.2
51.1
81.7
94.7
122
113
152
211
1.91
3.28
4.30
6.04
7.93
9.32
10.2
15.4
20.5
24.6
34.7
34.3
46.3
72.8
82.6
103
117
160
223
1.47
2.08
2.71
3.92
5.12
5.85
6.14
10.6
13.5
17.9
25.5
27.2
32.6
48.8
52.9
61.0
97.5
139
195
1.10
1.56
2.03
2.94
3.84
4.39
4.55
9.87
12.6
15.4
20.5
23.5
28.1
42.1
45.7
52.7
80.2
114
160
1.89
3.59
4.71
6.54
8.61
10.2
12.3
17.7
24.1
29.6
42.3
41.2
66.6
95.4
111
142
120
161
221
CONVENTIONAL CARTRIDGE THERMOSTATIC EXPANSION VALVES
0.71
1.59
2.33
3.50
5.60
7.36
9.81
0.67
1.50
2.21
3.03
4.85
6.37
8.49
0.70
1.58
2.23
3.06
5.04
6.65
8.65
0.55
1.24
1.63
2.34
4.05
5.40
6.75
0.48
1.07
1.40
2.02
3.49
4.66
5.82
0.63
1.42
2.05
3.16
5.05
6.63
8.84
0.69
1.56
2.29
3.44
5.50
7.22
9.63
0.66
1.48
2.18
2.98
4.77
6.26
8.34
BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES
0.80
1.59
3.59
6.48
9.81
LIQUID TEMPERATURE ENTERING TEV °C
REFRIGERANT -10° 0°
10° 20° 30° 40° 50° 60°
CORRECTION FACTOR, CF LIQUID TEMPERATURE
404A
1.98 1.79 1.60 1.41 1.21 1.00 0.79 0.56
507
1.92 1.74 1.56 1.37 1.19 1.00 0.79 0.54
These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they
may be used for any evaporator temperature from -15°C to 5°C since the variation
in the actual factors across this range is insignificant.
0.75
1.50
3.41
5.61
8.49
0.82
1.58
3.70
5.69
8.65
EVAPORATOR
TEMPERATURE
°C
5°
-5° & -15°
-20° & -30°
-40°
0.67
1.24
3.03
4.41
6.75
0.58
1.07
2.61
3.80
5.82
0.71
1.42
3.15
5.84
8.84
0.78
1.56
3.53
6.36
9.63
0.74
1.48
3.35
5.51
8.34
PRESSURE DROP ACROSS TEV (bar)
2
4
6
8
10
12
14
16
CORRECTION FACTOR, CF PRESSURE DROP
0.58 0.82 1.00 1.15 1.29 1.41 1.53 1.63
0.50 0.71 0.87 1.00 1.12 1.22 1.32 1.41
0.45 0.63 0.77 0.89 1.00 1.10 1.18 1.26
0.41 0.58 0.71 0.82 0.91 1.00 1.08 1.15
TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example:
Actual capacity of a nominal 1-1/2 ton R-404A Type FB valve at -5°C evaporator, 10 bar
pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 4.91 (from
rating chart) x 1.21 (CF liquid temperature) x 1.12 (CF pressure drop) = 6.65 kW.
CATALOG 301 — Page 23
THERMOSTATIC EXPANSION VALVES
410A
Air Conditioning and Heat Pump Applications
REFRIGERANT
410A
NOMINAL
RECOMMENDED
THERMOSTATIC
CHARGE
CAPACITY
VALVE TYPES
ZGA
EVAPORATOR TEMPERATURE °C
kW
5°
-5°
-15°
BALANCED PORT THERMOSTATIC EXPANSION VALVES
R-RC
R-RC
R-RC
R-RC
R-RC
R-RC
R-RC
R
R
R
O
O
O
O
O
3.5
5.3
7.0
11
14
18
21
28
44
53
70
88
120
180
210
VALVE TYPE
CARTRIDGE
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
BQ-EBQ-SBQ
AAA
AA
A
B
C
REFRIGERANT
410A
4.08
7.14
9.38
13.1
17.1
20.4
24.5
32.6
42.5
49.4
68.1
81.7
112
170
204
4.50
7.88
10.4
14.4
18.9
22.5
27.0
36.0
46.9
54.4
75.1
90.1
124
188
225
4.12
7.21
9.48
13.2
17.3
20.6
23.0
33.0
43.0
49.9
71.5
85.8
118
179
215
BALANCED PORT CARTRIDGE THERMOSTATIC EXPANSION VALVES
1.2
2.6
5.3
11
18
1.43
3.06
6.53
11.4
21.2
LIQUID TEMPERATURE ENTERING TEV °C
20°
30°
40°
50°
60°
CORRECTION FACTOR, CF LIQUID TEMPERATURE
1.30
1.15
1.00
0.84
0.65
These factors include corrections for liquid refrigerant density and net refrigerating effect and are based on an evaporator temperature of -15°C. However, they may
be used for any evaporator temperature from -15°C to 5°C since the variation in the
actual factors across this range is insignificant.
1.58
3.38
7.20
12.6
23.4
EVAPORATOR
TEMPERATURE
°C
5°
-5° & -15°
1.42
3.04
6.49
11.4
21.1
PRESSURE DROP ACROSS TEV (bar)
8
11
14
17
20
CORRECTION FACTOR, CF PRESSURE DROP
0.85
1.00
1.13
1.24
1.35
0.76
0.89
1.00
1.10
1.20
TEV Capacity = TEV Rating x CF Liquid Temperature x CF Pressure Drop — Example:
Actual capacity of a nominal 4 ton R-410A Type RC valve at -15°C evaporator, 17 bar
pressure drop across the TEV, and a 30°C liquid temperature entering the TEV = 17.3
(from rating chart) x 1.15 (CF liquid temperature) x 1.10 (CF pressure drop) = 21.9 kW.

Similar documents

Catalog 301 - Sporlan Online

Catalog 301 - Sporlan Online 1.  The Type ZP charges have essentially the same characteristics as the Type Z charge with one exception: they produce a pressure limit Maximum Operating Pressure (MOP). ZP charges are not intend...

More information

Catalog 201 - Sporlan Online

Catalog 201 - Sporlan Online FOR REFRIGERANTS: 22, 134a, 401A, 402A, 404A, 407C, 408A, 409A, 410A, 422D, 507 TEV capacity ratings for R-22, R-134a, R-401A, R-402A, R-404A, R-407C, R-408A, R-409A, R-410A, R-422D, and R-507 are ...

More information

Danfoss Catalog

Danfoss Catalog Examples of typical applications include: • Traditional refrigeration systems • Air conditioning systems • Transport refrigeration systems By pairing one valve body with one of eight replaceable...

More information

table of contents

table of contents on Page 9. These ratings are based on vapor free 86°F liquid refrigerant entering the TEV, a maximum opening superheat of 7°F, and a standard factory air test setting. For TEV capacity ratings at o...

More information