Entire catalog - SEW North Filtration
Transcription
Entire catalog - SEW North Filtration
DUST FILTER COMPONENTS Certified Header Tank Pulse Valves for Dust Collector Filters Electronic control Systems ™ TURBO TEAM 2008 Technical Development 1 TURBO HEADER TANKS Certified Header Tank ACCORDING TO 2009/105/EC AND PED 97/23/EC 2 Dust Filters Components TURBO HEADER TANKS RANGE TYPES CARBON STEEL TANKS (Integral, TF, TL, TD, Pack Series) TURBO TANKS Turbo can provide a complete range of header tanks for dust collector filters, according to 2009/105/EC and 97/23/EC PED Directives. Our tanks feature high performance coupled with long operational lifetime and can be tailored upon customer’s requirements. STAINLESS STEEL 1. Steel tanks (Integral, TF, TL, TD, Pack Series) 2. Aluminium tanks (Alutank Series) 3. AISI 304&316 stainless steel tanks (Integral, TF, TL, TD Series) A wide choice of accessories is also available including: Blow tube, Bulkhead connector, Electrical cable assembly with Matrix system, Electropneumatic cable assembly based on Turbo-Net system. Turbo can also supply ATEX94/9 /EC certified tanks that meet the following markings: ATEX II 2GD (zone 1 and 21) ATEX II 3GD(zone 2 and 22). ALUMINIUM (Alutank Series) All Turbo tanks are available in ATEX version. (You can find details of ATEX directive at the end of catalogue). 3 TURBO HEADER TANK TECHNICAL CHARACTERISTICS COIL Coil insulation DIN connector Protection DIN connector+Coil Option ATEX 94/9/CE Class H PG 9 EN 175301-803 IP 65 EN 60529 Group II Cat. 2GD + Group II Cat. 3GD Voltages 24V / 50-60 hz (±10%) 19VA 115V / 50-60 hz (± 10%) 19VA 230V / 50-60 hz (±-10%) 19VA 24 DC (+/- 10%) 18 Watt VALVE CONSTRUCTION Cover Body Pilot group Screws Diaphragm std Viton Diaphragm Plate Diaphragm TANK Fluids Pressure Temperature range of carbon steel Temperature range of stainless steel Option ATEX 94/9/CE TANK CAPACITY Dn 4” (114 mm) Dn 5” (139 mm) Dn 6” (168 mm) Dn 8” (219 mm) Dn 10” (273 mm) Dn 12” (324 mm) 4 Die cast aluminium Die cast aluminium Stainless steel Stainless steel Neoprene Viton Stainless steel Compressed air - Nitrogen 0,5 to 8 bar -20°C ; + 80°C -50°C ; + 200°C Group II Cat. 2 GD Group II Cat. 3 GD 9,5 13,70 20,10 34,90 53,50 76 liters/meter liters/meter liters/meter liters/meter liters/meter liters/meter TURBO HEADER TANKS RANGE TURBO PRODUCT RANGE - Global immersion Global immersion tanks offer superior performance thanks to the fully immersed diaphragm. - With threaded stub pipes Provide a solid coupling and high alignment assembly of valves. They make use of threaded pulse valves. - With plain tube This version makes it possible to achieve a quick and highly efficient valve assembly. - Aluminium tanks, Alutank Series Fully customised upon customer’s requirements, they feature light weight and easy handing. Thanks to the anodization process, they offer considerable protection against atmospheric agents and prevent oxidation. Besides, they ensure the availability of totally clean compressed air supply. ATEX II 2GDC ATEX II 3D CE STANDARD PED STANDARD STAINLESS STEEL PED ALUMINIUM PED 3 5 TURBO HEADER TANK GALLERY 6 CERTIFIED HEADER TANKS According to 2009/105/EC and 97/23/EC PED A1 GLOBAL IMMERSION INTEGRAL Series 2009/105/EC - 97/23/EC PED A2 THREADED STUB PIPE TF Series 2009/105/EC - 97/23/EC PED A3 THREADED STUB PIPE FOR STRAIGHT TROUGHT VALVE TL Series 2009/105/EC - 97/23/EC PED A4 PLAIN STUB PIPE TD Series 2009/105/EC - 97/23/EC PED A5 STAINLESS STEEL XTF Series 97/23/EC PED A6 GLOBAL IMMERSION ALUTANK Series 97/23/EC PED A7 AIR CANNON PACK Series A8 BLOW TUBES TS Series 2009/105/EC - 97/23/EC PED 7 HEADER TANKS According to 2009/105/EC and PED 97/23/EC HOW TO ORDER example TANK MODEL: GLOBAL IMMERSION THREADED STUB PIPE PLAIN STUB PIPE ALUMINIUM = = = = INTEGRAL 6 P 25 02450 N10 P150 B G1 INTEGRAL TF - TL TD ALUTANK TANK DIAMETER 4” = 4 5” = 5 6” = 6 8” = 8 10” = 10 12” = 12 INTEGRAL PILOT = P REMOTE PILOT = M VALVE DIAMETER 1/2” = 10 3/4” = 20 1” = 25 1”1/2 = 30 1”1/2 = 35 1”1/2 = 40 1”1/2 = 45 2” = 50 2”1/2 = 65 3” = 75 POWER SUPPLY 24V/50-60Hz =02450 115V/50-60Hz =11050 230V/50-60Hz =22050 24VDC =024DC N : NUMBER OF VALVES P : PITCH ROUND ENDS = B FLAT ENDS = F 8 BLOW TUBE SHORT PLAIN LONG PLAIN LONG THREADED SHORT THREADED = G1 = G2 = G3 = G4 Integral 6 P 25 02450 N10 P 150 B G1 identifies a global immersion tank (Integral) having 6” (6) diameter, integral electrical pilot (P), 1” (25) valves with 24V 50Hz (02450) coil voltage, equipped with no. 10 valves (N10) whose pitch is 150 mm (P150). Tank ends are round (B) and outlet stub pipes are plain (G1). GLOBAL IMMERSION HEADER TANK A1 According to 2009/105/EC and PED 97/23/EC INTEGRAL Series dn 4” with 1/2” valves DESCRIPTION VALVE SM10/SP10 1 2 3 4 5 6 7 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm 4” 1/2” 9 A1 GLOBAL IMMERSION HEADER TANK According to 2009/105/EC and PED 97/23/EC 5” INTEGRAL Series dn 5” with 3/4 ” valves DESCRIPTION VALVE SM20/SP20 1 2 3 4 5 6 6a BH10...V/50-60Hz TE6x18+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G Coil + Din connector Screws + Washers Pole assembly Cover direct drive Cover remote operated Diaphragm Spring BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE 10 G1 G2 = = = = G1 G2 G3 G4 G3 3/4 ” G4 GLOBAL IMMERSION HEADER TANK A1 According to 2009/105/EC and PED 97/23/EC INTEGRAL Series dn 6” with 3/4 ” valves DESCRIPTION VALVE SM20/SP20 1 2 3 4 5 6 6a BH10...V/50-60Hz TE6x18+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring 6” BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 G2 = = = = G1 G2 G3 G4 G3 3/4 ” G4 11 A1 GLOBAL IMMERSION HEADER TANK According to 2009/105/EC and PED 97/23/EC 6” INTEGRAL Series dn 6” with 1” valves DESCRIPTION VALVE SM25/SP25 1 2 3 4 5 6 6a BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE 12 G1 G2 = = = = G1 G2 G3 G4 G3 1” G4 GLOBAL IMMERSION HEADER TANK A1 According to 2009/105/EC and PED 97/23/EC INTEGRAL Series dn 6” with 1” 1/2 valves DESCRIPTION VALVE SM30/SP30 1 2 3 4 5 6 7 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP30 TCOP30FM TMOL25GHS M30 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 G2 = = = = G1 G2 G3 G4 G3 1”1/2 G4 13 A1 GLOBAL IMMERSION HEADER TANK According to 2009/105/EC and PED 97/23/EC 6” INTEGRAL Series dn 6” with 1” 1/2 valves DESCRIPTION VALVE SM35/SP35 1 2 3 4 5 6 7 8 9 10 11 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE6x20+TROND6GROWER TCOP35N TMOL25GHS M35 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm Screws + Washers Cover Spring Diaphragm BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE 14 G1 G2 = = = = G1 G2 G3 G4 G3 1”1/2 G4 GLOBAL IMMERSION HEADER TANK A1 According to 2009/105/EC and PED 97/23/EC INTEGRAL Series dn 8” with 1”valves DESCRIPTION VALVE SM25/SP25 1 2 3 4 5 6 6a BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring 8” BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 G2 = = = = G3 G1 G2 G3 G4 1” G4 15 A1 GLOBAL IMMERSION HEADER TANK According to 2009/105/EC and PED 97/23/EC 8” INTEGRAL Series dn 8” with 1”1/2 valves DESCRIPTION VALVE SM35/SP35 1 2 3 4 5 6 7 8 9 10 11 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE6x20+TROND6GROWER TCOP35N TMOL25GHS M35 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Cover remote operated Spring Diaphragm Screws + Washers Cover Spring Diaphragm BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET 1”1/2 G1 16 G2 G3 G4 GLOBAL IMMERSION HEADER TANK A1 According to 2009/105/EC and PED 97/23/EC INTEGRAL Series dn 8” with 1”1/2 valves DESCRIPTION VALVE SM40/SP40 1 2 3 4 5 6 6a 7 8 9 10 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE8x20+TROND8GROWER TCOP40N TMOL40 M40 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm 8” BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 G2 = = = = G3 G1 G2 G3 G4 1”1/2 G4 17 A1 GLOBAL IMMERSION HEADER TANK According to 2009/105/EC and PED 97/23/EC 8” INTEGRAL Series dn 8” with 1”1/2 valves DESCRIPTION VALVE SM45/SP45 1 2 3 4 5 6 7 8 9 10 11 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE8x20+TROND8GROWER TCOP45N TMOL40 M45 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Cover remote operated Spring Diaphragm Screws + Washers Cover Spring Diaphragm BRACKETS CS = COLLAR SA = HIGH BRACKET SM = MEDIUM BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 18 G2 = = = = G3 G1 G2 G3 G4 1”1/2 G4 GLOBAL IMMERSION HEADER TANK A1 According to 2009/105/EC and PED 97/23/EC INTEGRAL Series dn 10” with 1”1/2 valves DESCRIPTION VALVE SM40/SP40 1 2 3 4 5 6 6a 7 8 9 10 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE8x20+TROND8GROWER TCOP40N TMOL40 M40 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm 10” BRACKETS CS = COLLAR SA = HIGH BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 G2 = = = = G1 G2 G3 G4 G3 1”1/2 G4 19 A1 GLOBAL IMMERSION HEADER TANK According to 2009/105/EC and PED 97/23/EC 10” INTEGRAL Series dn 10” with 2” valves DESCRIPTION VALVE SM50/SP50 1 2 3 4 5 6 6a 7 8 9 10 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP50G TMOL40 M50 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm BRACKETS CS = COLLAR SA = HIGH BRACKET SB = SMALL BRACKET COLLAR BRACKET SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE 20 G1 G2 G3 = = = = G1 G2 G3 G4 2” G4 GLOBAL IMMERSION HEADER TANK A1 According to 2009/105/EC and PED 97/23/EC INTEGRAL Series dn 12” with 2”1/2 valves DESCRIPTION VALVE SM65/SP65 1 2 3 4 5 6 6a 7 8 9 10 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M76/SERB Coil + Din connector Screws + Washers Pole assembly Cover direct drive Cover remote operated Diaphragm Spring Screws + Washers Cover Spring Diaphragm 12” 2” 1/2 21 A1 GLOBAL IMMERSION HEADER TANK According to 2009/105/EC and PED 97/23/EC 12” INTEGRAL Series dn 12” with 3” valves DESCRIPTION VALVE SM75/SP75 1 2 3 4 5 6 6a 7 8 9 10 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M76/SERB Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm 3” 22 Technical Development 23 A2 HEADER TANK WITH THREADED STUB PIPES According to 2009/105/EC and PED 97/23/EC TF TF SERIES dn 5” - 6” - 8” - 10” - 12” Ø (Nom.) Ø (est) mm Ø E 5” 5” 6” 6” 6” 8” 8” 8” 10” 10” 10” 12” 12” 24 140 140 168,3 168,3 168,3 219,1 219,1 219,1 273 273 273 324 324 3/4” 1” 3/4” 1” 1”1/2 1” 1”1/2 2” 1”1/2 2” 21/2 2” 2”1/2 A B(min) ØF 50 50 50 50 50 70 70 70 90 90 90 - 45 45 45 45 55 45 55 60 55 60 70 60 65 1” 1” 1” 1” 1” 1”1/2 1”1/2 1”1/2 1”1/2 1”1/2 1”1/2 1”1/2 1”1/2 H M R Z(±) S(±) P(min) 10 10 10 10 10 10 10 10 12 12 12 20 20 85 85 85 85 85 85 85 85 85 75 75 75 75 40 40 40 40 40 40 40 40 40 40 40 40 40 120 120 120 120 136 120 136 164 136 164 164 164 164 190 190 204 204 220 229 245 273 272 300 300 325 325 85 85 85 85 150 85 150 210 150 210 210 210 210 THREADED STUB PIPE HEADER TANK A2 According to 2009/105/EC and PED 97/23/EC TF Series dn 5” - 6” - 8” - 10” - 12” DESCRIPTION VALVE FM20/FP20 VALVE FM25/FM25 1 Coil + Din connector 2 Screws + Washers 3 Pole assembly 4 Cover direct drive 5 Remote operated cover 6 Diaphragm 6a Spring 7 Body BH10...V/50-60Hz VTE6x20 +TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR20FFG BH10...V/50-60Hz VTE6x20 +TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR25FFG DESCRIPTION VALVE FP/FM40 VALVE FM55/FP55 VALVE FM65/FP65 1 2 3 4 5 6 6a 7 8 9 10 11 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE8x20+TROND8GROWER TCOP40N TMOL40 M40 TCOR40FFG BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M55/LP TCOR55FFG BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M76 TCOR65FFGP Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Main diaphragm Body TF 25 From R.&D. a new pulse valve SAVING & FLEXIBILITY The double advantage solution! THE DESIGN OFFERS EASE OF MAINTENANCE THANKS TO HORIZONTAL POSITION INTEGRATED COMPRESSION FITTING CONNECTOR ELIMINATES THE NEED FOR SEPARATE BULKHEAD CONNECTOR 26 DIRECT INSTALLATION THROUGH THE BAG HOUSE WALL SAME COMPONENTS THROUGH ALL TURBO PULSE VALVES RANGE 27 A3 HEADER TANK WITH THREADED STUB PIPES According to 2009/105/EC and PED 97/23/EC TL 28 TL Series dn 6”- 8” straight through dn1” -11/2“ Ø Ø (est) mm øE A B(min) ØF H M R Z(± S(±) P(min) Mounting bracket 6” 6” 8” 168,3 168,3 219,1 1”1/4 2” 2” 50 50 70 50 60 60 1” 1” 1”1/2 10 10 10 45 45 45 30 30 30 139 180 180 223 265 290 85 120 120 S6-223 S6-265 S8-290 THREADED STUB PIPE HEADER TANK A3 According to 2009/105/EC and PED 97/23/EC TL Series /Part List DESCRIPTION VALVE FDM25/FDP25 1 2 3 4 5 6 6a 7 8 9 10 11 12 BH10...V/50-60Hz VTE6x20 + TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR25FLG TRON80x53x5 TGBA25 GCON25 OG25 TDAL25 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Cover remote operated Diaphragm Spring Body Gasket Lock nut Conical seal Retainer ring Compression nut DESCRIPTION VALVE FDM35/FDP35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 11 12 BH10...V/50-60Hz VTE6x18 + TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE6x20 + TROND6GROWER TCOP35N TMOL25GHS M35 TCOR35FLG TRON100x70x5 TGBA40 GCON40 OG40 TDAL40 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Cover remote operated Spring Diaphragm Screws + Washers Cover Spring Diaphragm Body Gasket Lock nut Conical seal Retainer ring Compression nut TL 29 A4 HEADER TANK WITH PLAIN STUB PIPES According to 2009/105/EC and PED 97/23/EC TD TD Series dn 5” - 6” - 8” - 10” Ø (NOM) 5” 5” 6” 6” 6” 8” 8” 10” 30 Ø(est)mm ØE A B(min) ØF 140 140 168,3 168,3 168,3 219,1 219,1 273 3/4” 50 50 50 50 50 70 70 90 45 45 45 45 55 45 55 55 1” 1” 1” 1” 1” 1”1/2 1”1/2 1”1/2 1” 3/4” 1” 1”1/2 1” 1”1/2 1”1/2 H M Z(±) S(±) P(min) 10 10 10 10 10 10 10 12 85 85 85 85 85 85 85 85 130 130 130 130 138 130 138 138 200 200 215 215 223 240 248 275 85 85 85 85 150 85 150 150 HEADER TANK WITH PLAIN STUB PIPE A4 According to 2009/105/EC and PED 97/23/EC TD Series dn 5” - 6” - 8” - 10” DESCRIPTION VALVE DM20/DP20 VALVE DM25/DP25 1 2 3 4 5 6 6a 7 8 9 10 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR20/25MMG GCON20 OG20 TDAL20/25 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR25MMG GCON25 OG25 TDAL25 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Body Conical seal Retainer ring Compression nut DESCRIPTION VALVE DM40/DP40 1 2 3 4 5 6 6a 7 8 9 10 11 12 12 13 BH10...V/50-60Hz VTE6x20 + TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE8x20 + TROND8GROWER TCOP40N TMOL40 M40 TCOR40MMG GCON40 OG40 TDAL40 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Main diaphargm Body Conical seal Retainer ring Compression Nut TD 31 A5 STAINLESS STEEL HEADER TANKS WITH THREADED STUB PIPES According to PED 97/23/EC XTF XTF Series dn 5” - 6” - 8” Ø (nom) Ø (est) mm ØE A B (min) ØF H M R Z (±) S (±) P (min) 5” 5” 5” 6” 6” 6” 6” 8” 8” 8” 8” 140 140 140 168,3 168,3 168,3 168,3 219,1 219,1 219,1 219,1 3/4” 50 50 50 50 50 50 50 70 70 70 70 40 45 50 40 45 50 60 45 55 60 65 1” 1” 1” 1” 1” 1” 1” 11/2” 11/2” 11/2” 11/2” 15 15 15 15 15 15 15 18 18 18 18 85 85 85 85 85 85 85 85 85 85 85 40 40 40 40 40 40 40 40 40 40 40 120 120 120 120 120 136 164 120 136 164 164 190 190 190 204 204 220 248 229 245 273 273 85 85 150 85 85 150 210 85 150 210 210 1” 11/2” 3/4” 1” 11/2” 2” 1” 11/2” 2” 21/2” Temp. Range: -50°C +200°C A5 STAINLESS STEEL GLOBAL IMMERSION HEADER TANK According to PED 97/23/EC XTF INTEGRAL Series dn 5” - 6” - 8” Temp. Range: -50°C +200°C 32 MOUNTING BRACKETS A5 RANGE DN Tank Type of bracket Small bracket 5” (Ø 139,7) Medium bracket High bracket Small bracket 6” (Ø 168,3) 8” (Ø 219,1) 10” (Ø 273) Code of the bracket A (mm) B (mm) H (mm) S (mm) SB5 264 150 95 50 SM5 264 150 160 50 SA5 264 150 180 50 SB6 292 150 109 50 Medium bracket SM6 292 150 170 50 High bracket SA6 292 150 200 50 Series TL bracket S6-223 292 150 223 50 Series TL bracket S6-265 292 150 265 50 Small bracket SB8 348 200 134 50 Medium bracket SM8 348 200 210 50 High bracket SA8 348 200 270 50 Series TL bracket S8-290 348 200 290 50 Small bracket SB10 424 250 161 50 High bracket SA10 424 250 273 50 33 A6 ALUMINIUM GLOBAL IMMERSION HEADER TANK According to PED 97/23/EC 6” ALUTANK Series with dn 1” valves TECHNICAL CARECTERISTICS AIR PRESSURE B AIR PRESSURE B DESCRIPTION VALVE SQM25/SQP25 1 2 3 4 5 6 6a 7 8 9 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTCEI6x16 TCOR25IMO GOR65x4 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws Body O-ring •Tank Extruded anodized aluminium •Ends Die cast aluminium •Blow tube Steel zinc plated •O-Rings NBR •Temperature range -20°C +80°C •Operating pressure 0,5 ÷ 6 BAR - 0,5÷ 8 BAR •Low temperature - 40°C +80°C Blow tubes in Aluminium UV C P SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 34 G2 = = = = G3 G1 G2 G3 G4 1” G4 ALUMINIUM GLOBAL IMMERSION HEADER TANK A6 According to PED 97/23/EC Series ALUTANK with 1”1/2 valve 6” TECHNICAL CARECTERISTICS AIR PRESSURE B AIR PRESSURE B •Tank Extruded anodized aluminium •Ends Die cast aluminium •Blow tube Steel zinc plated •O-Rings NBR •Temperature range -20°C +80°C •Operating pressure 0,5 ÷ 6 BAR - 0,5 ÷ 8 BAR •Low temperature - 40°C +80°C Blow tubes in Aluminium DESCRIPTION VALVE SQM35/SQP35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE6x20+TROND6GROWER TCOP35N TMOL25GHS M35 VTCEI8x20 TCOR35FMGS GOR6337 Coil + Din connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm Screws + Washers Cover Spring Diaphragm Screws Body O-ring UV C P SHORT PLAIN TUBE LONG PLAIN TUBE THREADED LONG TUBE THREADED SHORT TUBE G1 G2 = = = = G3 G1 G2 G3 G4 1”1/2 G4 35 A7 AIR CANNON According to 2009/105/EC and PED 97/23/EC PACK PACK Series Type PACK 5 PACK 15 PACK 25 PACK 50 36 A 512 868 895 1174 B 140 (ø5”) 168,3 (ø6”) 219,1 (ø8”) 273 ( ø10”) C 100 124 160 214 E ØF 100 100 150 185 3/4” 1” 1”1/2 2” G 90 90 133,5 198 ØH 73 73 135 190 I 38 38 62 83 L 232 368 375 539 M 150 280 320 320 N 120 160 260 260 ØO ØP Q 13 13 13 13 1/2” 250 250 350 350 1/2” 1/2” 1/2” BLOW TUBE TS SERIES HOW TO ORDER A8 TS TS 25 P100 N10 D10 L150 F200 H15 A2 T2 TS: BLOW TUBE Ø D: BLOW TUBE DIAMETER 20 3/4” 25 1” 40 1”1/2 50 2” P: INJECTOR PITCH N: Q.TY OF INJECTOR D: INJECTOR DIAMETER L: DISTANCE BETWEEN FILTER WALL AND INJECTOR F: DISTANCE BETWEEN INJECTOR TO END OF B.T. H: INJECTOR HEIGHT A1: PLAIN A2: THREADED T1: PLUG T2: BRACKET T1 A1 A2 T2 DESCRIPTION 1 2 3 4 5 6 Tube Injector O-Ring Plug Bracket Screws 37 38 PULSE VALVES Pulse Valves for Dust Collector Filters 39 TURBO PULSE VALVES R&D 40 TURBO PULSE VALVES RANGE TURBO VALVES Turbo has a complete range of pulse valves for dust collector filters able to meet all customers technical requirement. Turbo valves are designed to have a long life and excellent performance in terms of opening and closing with low air consumption. Turbo products range includes: 1 - Threaded pulse valves (F Series) 2 - Compression fittings pulse valves (D Series) 3 - Flanged pulse valves (E Series) 4 - Pulse valves for square tank (SQ Series) 5 - Straight through pulse valves (FD Series) Same valves are available in compliance with ATEX 94/9/EC: ATEX II 2 GD (zone 1 and 21) ATEX II 3 GD (zone 2 and 22). (You can find details of ATEX directive at the end of catalogue). 41 PULSE VALVES HOW TO ORDER example F D E SQ FD : : : : : THREADED VALVE COMPRESSION FITTINGS VALVE FLANGED VALVE GLOBAL VALVE FOR SQUARE TANK STRAIGHT THROUGH VALVE P = INTEGRAL PILOT M = REMOTE PILOT CONNECTION DIAMETERS 3/4” = 20 1” = 25 1”1/2 = 40 1”1/2 = 45 2” = 55 2”1/2 = 65 3” = 75 4” = 100 STANDARD VOLTAGES 24V/50-60Hz =02450 115V/50-60Hz =11050 230V/50-60Hz =22050 24VDC =024DC 42 F P 25 02450 Dust Filters Components PULSE VALVES B1 Pulse valve with threaded connection F Series B2 Pulse valves with compression fitting D Series B3 Pulse valves with flange inlet E Series B4 Pulse valves for square tank SQ Series B5 Pulse valves straight through FD Series 43 B1 THREADED PULSE VALVE F F Series CHARACTERISTICS Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt DESCRIPTION VALVE FM20/FP20 VALVE FM25/FP25 1 Coil +Din Connector 2 Screws + Washers 3 Pole assembly 4 Cover direct drive 5 Remote operated cover 6 Diaphragm 6a Spring 7 Body BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR20FFG BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR25FFG FP Integral solenoid pilot version / FM Remote pilot version DESCRIPTION VALVE FM40/FP40 VALVE FM55/FP55 VALVE FM65/FP65 1 Coil + Din Connector 2 Screws + Washers 3 Pole assembly 4 Cover direct drive 5 Remote operated cover 6 Diaphragm 6a Spring 7 Screws + Washers 8 Cover 9 Spring 10 Main diaphragm 11 Body BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE8x20+TROND8GROWER TCOP40N TMOL40 M40 TCOR40FFG BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M55/LP TCOR55FFG BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M76 TCOR65FFGP FP Integral solenoid pilot version / FM Remote pilot version 44 THREADED PULSE VALVE B 1 Overall dimensions / F Series Model Ø L (nom) A B C D E Weight (Kg) FP 20 3/ “ 4 52 90 20,5 74 ~125 0,6 FP 25 1“ 52 90 20,5 74 1”1/2 71,3 135 31 140 ~125 ~188 0,5 FP 40 FP 55 2“ 114 203 40 194 2”1/2 114 203 48 194 ~225 ~225 3,7 FP 65 FM 20 3/ “ 4 52 90 20,5 74 0,4 FM 25 1“ 52 90 20,5 74 ~67 ~67 FM 40 1”1/2 71,3 135 31 140 ~130 1,4 FM 55 2“ 114 203 40 194 FM 65 2”1/2 114 203 48 194 ~167 ~167 3,4 Note: Threads can also be implemented in NPT. For information, please contact our technical Department. F 1,6 3,6 0,3 3,5 45 B1 THREADED PULSE VALVE F F Series CHARACTERISTICS DESCRIPTION VALVE FM45/FP45 1 2 3 4 5 6 7 8 9 10 11 12 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE8x20+TROND8GROWER TCOP45N TMOL40 M45 TCOR40FFG Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm Screws + Washers Cover Spring Diaphragm Body FP Integral solenoid pilot version / FM Remote pilot version 46 Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt THREADED PULSE VALVE B 1 Overall dimensions / F Series Model Ø L (nom) A B C D E Weight (Kg) FP 45 1”1/2 71,3 135 31 140 ~180 1,6 FM 45 1”1/2 71,3 135 31 140 ~122 1,4 F 47 B2 COMPRESSION FITTING PULSE VALVE D D Series CHARACTERISTICS Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt DESCRIPTION VALVE DM20/DP20 VALVE DM25/DP25 1 Coil +Din Connector 2 Screws + Washers 3 Pole assembly 4 Cover direct drive 5 Remote operated cover 6 Diaphragm 6a Spring 7 Body 8 Conical seal 9 Retainer ring 10Compression nut BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR20/25MMG GCON20 OG20 TDAL20/25 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR25MMG GCON 25 OG25 TDAL25 DP Integral solenoid pilot version / DM Remote pilot version DESCRIPTION VALVE DM40/DP40 1 2 3 4 5 6 6a 7 8 9 10 11 12 13 14 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE8x20+TROND8GROWER TCOP40N TMOL40 M40 TCOR40MMG GCON40 OG40 TDAL40 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Main Diaphragm Body Conical seal Retainer ring Compression nut FP Integral solenoid pilot version / FM Remote pilot version 48 Model Ø L (nom) DP 20 3/ “ 4 A DP 25 1“ DP 40 1”1/2 66 DM 20 3/ “ 4 DM 25 1“ DM 40 1”1/2 66 COMPRESSION FITTING PULSE VALVE B2 Overall dimensions / D Series D B C E ØF G H I Weight (Kg) 48 90 128 48 74 80 1,1 90 128 ~189 ~189 28,5 48 35 48 74 80 1 114 180 50 66 140 101 2,5 48 90 128 ~264 ~131 28,5 48 74 80 1,1 48 90 128 ~131 35 48 74 80 0,9 114 180 ~206 50 66 140 101 2,3 49 B3 FLANGED PULSE VALVES E E Series CHARACTERISTICS Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt DESCRIPTION VALVE EM25/EP25 1 2 3 4 5 6 6a 7 8 9 10 11 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25/EM TCOP25FM/EM M25/EM/EP TMOL10G TCOR25FMG G CON25 OG25 TDAL25 G OR55x6 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Body Conical seal Retainer ring Compression nut O-ring EP Integral solenoid pilot version EM Remote pilot version DESCRIPTION VALVE EM40/EP40 1 2 3 4 5 6 6a 7 8 9 10 11 12 13 14 15 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE8x20+TROND8GROWER TCOP40N TMOL40 M40 TCOR40FMG GCON40 OG40 TDAL40 G OR64,3x5,7 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Main diaphragm Body Conical seal Retainer ring Compression nut O-ring EP Integral solenoid pilot version EM Remote pilot version 50 FLANGED PULSE VALVES Overall dimensions / D Series Model ØC A B ØD F G I L M N ØE Weight (Kg) EP 25 1“ 60 82 9 82 74 119 106 217 81 1“1/2 1 EP 40 1“1/2 72 99 11 96 140 160 115 278 96 2” 2,3 0,9 2,1 EM 25 1“ EM40 1“1/2 60 82 9 82 74 119 106 159 81 1“1/2 72 99 11 96 140 160 115 220 96 2” B3 E 51 B4 GLOBAL PULSE VALVES FOR SQUARE TANK SQ SQ Series - Ø 1” CHARACTERISTICS Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt DESCRIPTION VALVE SQM25/SQP25 DESCRIPTION VALVE SQMO25/SQPO25 1 2 3 4 5 6 6a 7 8 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR25IM G OR65x4 1 2 3 4 5 6 6a 7 8 9 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTCEI6x16 TCOR25IMO G OR65x4 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Body O-ring SQP Integral solenoid pilot version / SQM Remote pilot version Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws Body O-ring SQPO Integral solenoid pilot version / SQMO Remote pilot version 52 GLOBAL PULSE VALVES FOR SQUARE TANK B4 Overall dimensions / SQ Series SQ Model ØA ØB ØC ØD ØE ØM F G H I L Weight (Kg) SQPO 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 136 6,2 0,7 SQP 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 136 6,2 0,7 SQMO 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 78 6,2 0,5 SQM 25 1“ 41,4 62,2 104 116 92 25 31,5 20,2 78 6,2 0,5 53 B4 GLOBAL PULSE VALVES FOR SQUARE TANK SQ SQ Series - Ø 1” 1/2 CHARACTERISTICS Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt DESCRIPTION VALVE SQM35/SQP35 DESCRIPTION VALVE SQO35/SQPO35 1 2 3 4 5 6 7 8 9 10 11 12 13 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE6x20+TROND6GROWER TCOP35N TMOL25GHS M35 TCOR35FMG G OR6337 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE6x20+TROND6GROWER TCOP35N TMOL25GHS M35 VTCEI8x20 TCOR35FMGS G OR6337 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm Screws + Washers Cover Spring Diaphragm Body O-ring SQP Integral solenoid pilot version SQM Remote pilot version 54 Fluid Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm Screws + Washers Cover Spring Diaphragm Screws Body O-ring SQPO Integral solenoid pilot version SQMO Remote pilot version GLOBAL PULSE VALVES FOR SQUARE TANK Overall dimensions / SQ Series - Ø1” 1/2 Model ØA ØB ØC ØD ØE F G H M Weight (Kg) SQP 35 1”1/2 1”1/2 1”1/2 1”1/2 57 80,5 114 9 42 26 162 130 1,6 57 80,5 114 9 42 26 162 130 1,6 57 80,5 114 9 42 26 104 130 1,4 57 80,5 114 9 42 26 104 130 1,4 SQPO 25 SQM 35 SQMO 35 B4 SQ 55 B4 GLOBAL PULSE VALVES FOR SQUARE TANK SQ SQ Series - Ø 2” - 2”1/2 - 3”- 4” CHARACTERISTICS Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt DESCRIPTION VALVE SQM50/SQP50 DESCRIPTION VALVE SQM65IN/SQP65IN 1 2 3 4 5 6 6a 7 8 9 10 11 12 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP50G TMOL40 M50 TCOR50FG G OR133,35x5,3 1 2 3 4 5 6 6a 7 8 9 10 11 12 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M55/LP TCOR65FLQ G OR177,17x6,99 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm Body O-ring SQP Integral solenoid pilot version SQM Remote pilot version SQP Integral solenoid pilot version SQM Remote pilot version DESCRIPTION VALVE SQM75IN/SQP75IN DESCRIPTION VALVE SQM100IN/SQP100IN 1 2 3 4 5 6 6a 7 8 9 10 11 12 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M76 TCOR75FLQ G OR177,17x6,99 1 2 3 4 5 6 6a 7 8 9 10 11 12 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25/BW TMOL10G VTE10x25+TROND10GROWER TCOP65G TMOL40 M76 TCOR100FLQ G OR177,17x6,99 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm Body O-ring SQP Integral solenoid pilot version SQM Remote pilot version 56 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm Body O-ring Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Screws + Washers Cover Spring Diaphragm Body O-ring SQP Integral solenoid pilot version SQM Remote pilot version GLOBAL PULSE VALVES FOR SQUARE TANK Overall dimensions / SQ Series - Ø 2” -2” 1/2 - 3”- 4” Model ØA ØB ØC ØD ØE F G H I L Weight (Kg) SQP 50 2“ 83 126 175 195 39 60 20 211 11 2,4 SQP 65IN 2”1/2 107,5 161 225 247 44 35,5 27 205 11 3,9 SQP 75IN 3“ 107,5 161 225 247 50 35,5 27 205 11 3,7 SQP 100IN 4“ 119,5 161 225 247 44 35,5 27 205 11 3,8 SQM 50 2“ 83 126 175 195 39 60 20 153 11 2,2 SQM 65IN 2”1/2 107,5 161 225 247 44 35,5 27 147 11 3,7 SQM 75IN 3“ 107,5 161 225 247 50 35,5 27 147 11 3,5 SQM 100IN 4“ 119,5 161 225 247 44 35,5 27 148 11 3,6 B4 SQ 57 B5 STRAIGHT THROUGH PULSE VALVE FD FD Series Ø1” CHARACTERISTICS DESCRIPTION VALVE FDM25/FDP25 1 2 3 4 5 6 6a 7 8 9 10 11 12 BH10...V/50-60Hz VTE6x20+TROND6GROWER GPC10 TCOP25 TCOP25FM M25 TMOL10G TCOR25FLG TRON80x53x5 TGBA25 G CON25 OG25 TDAL25 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Diaphragm Spring Body Gasket Lock nut Conical seal Retainer ring Compression Nut FDP Integral solenoid pilot version FDM Remote pilot version 58 Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt GLOBAL PULSE VALVES FOR SQUARE TANK Overall dimensions / FD Series - Ø1” Model ØA ØB ØC ØD ØE F G H Weight (Kg) FDP25 1”1/4 1” 114 172 27 74 132 49,5 1,2 FDM25 1”1/4 1” 114 172 27 74 74 49,5 1 B5 FD 59 B5 STRAIGHT THROUGH PULSE VALVE FD FD Series Ø1” 1/2 CHARACTERISTICS DESCRIPTION VALVE FDM35/FDP35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 BH10...V/50-60Hz VTE6x18+TROND6GROWER GPC10 TCOP10 TCOP10FM TMOL10G M10 VTE6x20+TROND6GROWER TCOP35N TMOL25GHS M35 TCOR35FLG TRON100x70x5 TGBA40 G CON40 OG40 TDAL40 Coil + Din Connector Screws + Washers Pole assembly Cover direct drive Remote operated cover Spring Diaphragm Screws + Washers Cover Spring Diaphragm Body Gasket Lock nut Conical seal Retainer ring Compression Nut FDP Integral solenoid pilot version FDM Remote pilot version 60 Fluid Filtered and oilfree compressed air Temperature range STD diaphragm -20°C; +80°C Viton diaphragm -20°C; +200°C Operating pressure Body and cover Core tube Plunger Screws Coil insulation Din’s connector Protection Din’s connector + Coil Standard voltage min 0,5 bar - max 7,5 bar Die cast aluminium Stainless steel Stainless steel Stainless steel Class H PG 9 EN175301-803 IP65 EN60529 24V/50-60Hz (±10%) 19VA 115V/50-60Hz (±10%) 19VA 230V/50-60Hz (±10%) 19VA 24VDC (± 10%) 18 Watt GLOBAL PULSE VALVES FOR SQUARE TANK B5 Overall dimensions / FD Series - Ø1” 1/2 FD Model ØA ØB D E F G H Weight (Kg) FDP35 2” 1”1/2 155 228 32 115 186 67,5 2,3 2” 1”1/2 228 32 115 131 67,5 2,1 FDM35 C 155 61 62 BULKHEAD CONNECTORS C1 Bulkhead connector PS/PD Series C2 Wrench SG/SD Series 63 C1 PS/PD BULKHEAD CONNECTORS PS/PD Series P Series Bulkhead connectors provide a simple and economic solution to installation by eliminating the need for welding or threaded pipe connections. ∑ • PD Series is a double ended connector for two-piece blow tube • PS Series is a single ended connector for one-piece blow tube ∑ 64 DESCRIPTION PS20 PS25 PS40 PS50 1 2 3 4 5 6 TDAL20/25 OG20 G CON20 TGBA25 TFIBRA70x54x1,5 TPAS20/LAV TDAL25 OG25 G CON25 TGBA25 TFIBRA70x54x1,5 TPAS25/LAV TDAL40 OG40 G CON40 TGBA40 TFIBRA90x70x1,5 TPAS40/LAV TDAL50 OG50 G CON50 TGBA50 TRON115x88x5 TPASS50/LAV Compression nut Retainer ring Conical seal Lock nut Gasket Body DESCRIPTION PD20 PD25 PD40 PD50 1 2 3 4 5 6 TDAL20/25 OG20 G CON20 TGBA25 TFIBRA70x54x1,5 TPAS20 TDAL25 OG25 G CON25 TGBA25 TFIBRA70x54x1,5 TPAS25 TDAL40 OG40 G CON40 TGBA40 TFIBRA90x70x1,5 TPAS40 TDAL50 OG50 G CON50 TGBA50 TRON11x88x5 TPASS50 Compression nut Retainer ring Conical seal Lock nut Gasket Body BULKHEAD CONNECTORS C1 Overall dimensions / PS/PD Series PS/PD Model ØA B C1 D E F Weight (Kg) PS 20 PS 25 PS 40 PS 50 3/ ” 4 10,5 10,5 15 15,5 12,5 12,5 16,5 29 67 67 92 98 35 35 40 42 56 56 79 83 0,5 0,4 0,8 1,6 1” 1” 1/2 2” Model ØA B B1 C D E F Weight (Kg) PD 20 PD 25 PD 40 PD 50 3/ ” 4 10,5 10,5 15 15,5 12,5 12,5 16,5 29 35 35 40 42 105 105 140 150 50 50 67 - 39 39 55 - 0,7 0,6 1,2 2,2 1” 1” 1/2 2” TECHNICAL CHARACTERISTICS Body, lock nut, compression nut Die cast aluminium Seal NBR Silicon 3/4” 1” 1” 1/2 2” ASSEMBLY HOLE -30°C / +100°C -60°C / +200°C Wall hole ø min. 56 Wall hole ø min. 56 Wall hole ø min. 72 Wall hole ø min. 93 65 C2 SG/SD WRENCH SG/SD Series WRENCH SD FOR COMPRESSION NUT 66 WRENCH SG FOR LOCK NUT Model Ø A H L Model Ø A H L SD20 SD25 SD40 SD50 3/4” 61 61 82 110 70 70 85 100 350 350 430 430 SG20 SG25 SG40 SG50 3/4” 70 70 90 120 65 65 85 100 350 350 430 430 1” 1”1/2 2” 1” 1”1/2 2” REMOTE SOLENOID ENCLOSURES Remote Solenoid Enclosures D1 RCP Series D2 RLD Series D3 TRCP Series 67 D REMOTE SOLENOID ENCLOSURES D HOW THE ORDER REMOTE SOLENOID ENCLOSURES ACCORDING TO ATEX IP66 II 3D T100°C NEMA 4 UL50 Turbo offer a range of pilot valve boxes for outdoor applications and hazardous locations. Model available: ∑ • RCP maximum lenght of pilot tubes 3m ∑ • RLD maximum lenght of pilot tubes 10m Tubes 6 or 8 mm should be used for pneumatic connections to the pulse valves. Remote solenoid enclosures RCP and RLD are supplied with pre-wired electric common terminals. TRCP remote solenoid enclosures have all coils electrical complete cabled on the printed circuit inside the enclosure. Thermostat with heater is reccomemded to prevent moisture or freezing inside of remote solenoid enclosures. This system ensures a minimum temperature of 5°C inside the enclosure. example RCP : RLD : TRCP : RCP 5 V/... R PILOT VALVE BOX IP 66 PILOT VALVE BOX IP 66 PILOT VALVE BOX IP 66 NUMBER OF PILOT VALVES RCP 1-2-3-4-5 (Enclosure small) RCP 6-7-8 (Enclosure medium) RCP 9-10-11-12 (Enclosure large) TRCP 1-2-3-4-5-6-7-8 (Enclosure medium) VOLTAGE 24V/50-60Hz =02450 115V/50-60Hz =11050 230V/50-60Hz =22050 24VDC =024DC (TRCP = 024DC - 5W) Heating thermostat (option) Power 70W for RCP5 Power 120W for RCP8 and RCP12 Code RCP5V/...R is for a remote solenoid enclosures IP 66 (RCP) with five pilots mounted electrical (5), power supply 24V 50Hz (V/...), with heating thermostat (R). 68 SAMPLE INSTALLATION RCP REMOTE SOLENOID ENCLOSURES D1 RCP Series RCP CHARACTERISTICS Fluid Operating pressure Filtered and oilfree compressed air min 0,5 bar - max 7,5 bar Temperature range W/Heating Base and cover Core tube Plunger Screws Coil insulation Protection Standard voltages -20°C +80°C -40°C +80°C Die cast aluminium Stainless steel Stainless steel Stainless steel Class H IP66 230 -110 - 24V 50-60VHz 19 VA 24VDC 15W (*) Minimum distance to allow the opening of the cover RCP5 RCP8 RCP12 Model A B C D E ØM ØN Weight (Kg) RCP5 210 98 10 156 100 11 1,7 RCP8 333 98 10 267 100 RCP12 306 97 10 237 152 1/ “ 8 1/ “ 8 1/ “ 8 11 3,2 11 4,4 69 D2 REMOTE SOLENOID ENCLOSURES RLD RLD Series CHARACTERISTICS Fluid Operating pressure Filtered and oilfree compressed air min 0,5 bar - max 7,5 bar Temperature range W/Heating Base and cover Core tube Plunger Screws Coil insulation Protection Standard voltages -20°C +80°C -40°C +80°C Die cast aluminium Stainless steel Stainless steel Stainless steel Class H IP66 230 -110 - 24V 50-60VHz 19 VA 24VDC 15W (*) Minimum distance to allow the opening of the cover RLD5 RLD8 RLD12 70 Model A B C D E ØM ØN Weight (Kg) RLD5 210 98 10 156 100 11 1,7 RLD8 333 98 10 267 100 11 3,2 RLD12 306 97 10 237 152 1/ “ 8 1/ “ 8 1/ “ 8 11 4,4 REMOTE SOLENOID ENCLOSURES D3 TRCP Series TRCP CHARACTERISTICS Fluid Operating pressure Filtered and oilfree compressed air min 0,5 bar - max 7,5 bar Temperature range Base and cover Core tube Plunger Screws Coil insulation Protection Standard voltages -20°C +80°C Die cast aluminium Stainless steel Stainless steel Stainless steel Class H IP66 24VDC (5W) (*) Minimum distance to allow the opening of the cover Model TRCP8 A 333 B 136,5 C 10 D 267 E ØM ØN Weight (Kg) 100 1/ “ 8 11 3,3 71 72 REMOTE PILOTS Remote Pilots E1 SR Series TSRM Series E2 LD Series 73 E REMOTE PILOTS HOW TO ORDER REMOTE PILOT VALVE Designed for panel mounting or Turbo boxes. Two models are available: ∑ • Series SR/TSRM, max. lenght of pilot tubes 3m ∑ • Series LD, max. lenght of pilot tubes 10m Two ways normally closed. Tubes 6 or 8 mm. diameter should be used for pneumatic connections to the pulse valves. example SRC : SRM : TSRM: LDC : LDM : SRM 02450 PILOT VALVE WITH CONNECTOR PILOT VALVE SCREWS TERMINAL PILOT VALVE WITH FASTON CONNECTION PILOT VALVE WITH CONNECTOR PILOT VALVE SCREWS TERMINAL VOLTAGE 24V/50-60Hz =02450 115V/50-60Hz =11050 230V/50-60Hz =22050 24VDC =024DC (TSRM = 024DC - 5W9) Code SRM02450 is for pilot valve with screws terminal (SRM) power supply 24V 50Hz (02450). 74 REMOTE PILOTS E1 SR/TSRM Series SR/TSRM CHARACTERISTICS Fluid Operating pressure Filtered and oilfree compressed air min 0,5 bar - max 7,5 bar Temperature range Body Core tube Plunger Coil insulation Connector Standard voltages -20°C +80°C Brass Stainless steel Stainless steel Class H PG9 / IP 65 230 -110 - 24V/50-60VHz (19 VA) 24VDC (15W) - 24VDC (5W) SRC - IP65 24V DC 15WATT Available with ATEX coil zone 21 and zone 22 SRM - IP00 24V DC 15WATT SAMPLE INSTALLATION 3 mt a mx 75 E1 REMOTE PILOTS SR/TSRM SR/TSRM Series SRC SRM Description SRC Description SRM 1 2 3 4 PCRP TGHIERA 18x1 + G OR3081 GPC10 BH10 1 2 3 4 PCRP TGHIERA 18x1 + G OR3081 GPC10/R BH10.../.. - A9 Body Lock nut +O-ring Pole assembly Coil + Din Connector Body Lock nut +O-ring Pole assembly Coil TSRM 76 Description TSRM 1 2 3 4 5 PCRP TGHIERA 18x1 + G OR3081 GPC10/R BH10 024/DC/5W - A9 Body Lock nut +O-ring Pole assembly Coil Quick fitting for rilsan tube 6x4 TGOMINNRAP REMOTE PILOTS E2 Remote pilots for long distance/LD Series LD CHARACTERISTICS Fluid Operating pressure Filtered and oilfree compressed air min 0,5 bar - max 7,5 bar Temperature range Body Core tube Plunger Coil insulation Connector Standard voltages -20°C +80°C Brass Stainless steel Stainless steel Class H PG9 / IP 65 230 -110 - 24V/50-60VHz (19 VA) 24VDC (15W) LDC C 24V DC 15WATT Available with ATEX coil zone 21 and zone 22 LDM C 24V DC 15WATT SAMPLE INSTALLATION 10 mt ax m 77 E2 REMOTE PILOTS LD Remote pilots for long distance/LD Series LDC DESCRIPTION LDC 1 2 3 4 PCRPLD TGHIERA18x1+G OR3081 GPC10 BH10.../.. Body Lock nut + O-ring Pole assembly Coil + Din connector DESCRIPTION LDM 1 2 3 4 PCRPLD TGHIERA18x1+G OR3081 GPC10/R BH10.../.. - A9 Body Lock nut + O-ring Pole assembly Coil LDM 78 ATEX PULSE VALVES ATEX Turbo pulse valves for potentially explosive atmospheres according to ATEX 94/9/EC valve is provided with molded coil and connector IP 65. Valve dimensions are same of standard model. ATEX II3GD (zone 2 and 22) Turbo pulse valves for potentially explosive atmospheres according to ATEX 94/9/EC. Valve use encapsulated molded coil with leads wire of different lenght. Pilot valve has brass body that change valve dimensions from standard model. ATEX II2GD (zone 1 and 21) 79 94-9-CE ATEX DIRECTIVE ATEX The European Community 94/9/EC Directive establishes the constructional and functional requirements (mandatory since 01/07/2003) for equipment and protection systems intended for use in potentially explosive atmosphere. The Directive considers explosion hazard due to each source of ignition (electrical and not electrical), and the main important aspects introduced are: - Essential Health and Safety Requirements (Annex II-ESR) - Applicability both to materials used for underground mining (group I) and for those used in surface (Group II) - Classification of equipment in “categories” according to required protection level - Production surveillance based on Quality Management Systems Directive 94/9/EC considers for the first time the explosion hazard due to a non-electrical source of ignition, such as mechanical sparks caused by vibrations or impact, high surface temperature of mechanical and electrical components caused by non-electrical sources such as vibrations, high rotating speed, etc. Furthermore the Directive establishes to carefully evaluate the environment of installation of the equipment, its storage and functioning, in order to classify it according to a possible presence of explosive atmosphere. The Directive, in fact, through the Essential Health and Safety Requirements considers that equipment themselves can be a source of explosive atmosphere and provides for requirements in order to prevent such risks (Annex II point 1.0.1.) Aim of the European Directive. Directive 94/9/EC (ATEX) was adopted by the European Community to ensure free movement of products intended for use in potentially explosive atmospheres. It provides for harmonized technical requirements and applicable standards. This Directive aims to preserve people’s health and goods from risks coming from the use of equipment and protection systems in a "potentially explosive atmosphere. Explosive atmosphere is a mixture with air, under specific atmospheric conditions (temperature from -20°C to +40°C and pressure from 0,8 bar to 1,1 bar according to EN60079 and EN13463-1), of flammable substances in the form of gases, vapors, mists or dusts in which, after ignition has occurred, combustion spreads to the entire unburned mixture (see also Directive 94/9/EC Cap. I art. 1) Potentially explosive atmosphere is an atmosphere that could become explosive due to local operating conditions Hazardous explosive areas according to Directive 1992/92/CE. Areas where hazardous explosive atmospheres may occur are classified into zones based on their likelihood and persistence. Zone 0 Area in which an hazardous explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. Zone 1 Area in which an hazardous explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally Zone 2 Area in which an hazardous explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. 80 NOTE ELECTRONIC SYSTEMS PRODUCT OVERVIEW LA ATEX CERTIFIED (zone 1,2,21 & 22) SEQUENCERS ECONOMISERS EMISSION MONITORING SYSTEMS AND TRIBO-CHECK PROBES CONTROL UNITS WITH REMOTE PILOTS MATRIX WIRING SYSTEM TURBONET BUS SYSTEM 82 ELECTRONIC SYSTEMS Electronic control Systems DUST FILTER COMPONETS 83 ECONOMISERS AND SEQUENCERS HOW TO ORDER ECONOMISER E SERIES example E 16 M B E 4 - 8 - 12 -16 NUMBER OF OUTPUTS U=24Vcc B=24V 50-60Hz L=115V 50-60Hz M=230V 50-60Hz STANDARD MULTIPLE SUPPLY VOLTAGE U=24Vcc B=24V 50-60Hz L=115V 50-60Hz M=230V 50-60Hz MULTIPLE OUTPUT VOLTAGE ECONOMISER BA SERIES example E16 MB is a 16-way E economiser with 230 VAC supply voltage and 24VAC output voltage BA 16 M B BA 4 - 8 - 12 -16 NUMBER OF OUTPUTS M=230V 50-60Hz L=115V 50-60 Hz STANDARD SUPPLY VOLTAGE U=24Vcc B=24V 50-60Hz OPTIONAL SUPPLY VOLTAGE U=24Vcc B=24V 50-60HZ L=115V 50-60HZ M=230V 50-60Hz MULTIPLE OUTPUT VOLTAGE BA16 MB is a 16-way BA economiser with 230 VAC supply voltage and 24VAC output voltage SEQUENCER S SERIES example S 16 M B S 4 - 8 - 12 -16 NUMBER OF OUTPUTS U=24Vcc B=24V 50-60Hz L=115V 50-60Hz M=230V 50-60Hz STANDARD MULTIPLE SUPPLY VOLTAGE U=24Vcc B=24V 50-60HZ L=115V 50-60HZ M=230V 50-60Hz MULTIPLE OUTPUT VOLTAGE S16 MB is a 16-way S sequencer with 230 VAC supply voltage and 24VAC output voltage SEQUENCER PA SERIES example PA 16 M B PA 4 - 8 - 12 -16 NUMBER OF OUTPUTS M=230V 50-60Hz L=115V 50-60Hz STANDARD SUPPLY VOLTAGE U=24Vcc B=24V 50-60Hz OPTIONAL SUPPLY VOLTAGE U=24Vcc B=24V 50-60HZ L=115V 50-60HZ M=230V 50-60HZ MULTIPLE OUTPUT VOLTAGE )% PA16MB is a16-way sequencer with 230 VAC supply voltage and 24VAC output voltage Dust Filters Components PRODUCT INDEX Economiser with digital ∆P control E Series Economiser with digital ∆P control BA Series Cyclic sequencer S Series Cyclic sequencer PA Series Digital ∆P controller BP B Series Electronic single timer TCONTEMP TURBONET Bus system TURBO-NET 144 MATRIX Wiring system MTX Dust emission probe TC Dust emission probe controller DTC Series Series )& ECONOMISER FOR DEDUSTING PLANTS WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER E E Series Description The control instruments “E” series economizer are among the most modern and complete available today on the market. They have been built to command membrane solenoids on dust removal filters. A large back lighted liquid crystal display clearly shows the filter and the cleaning system status. It has a fast-flow setting menu with intuitive operation that allows the operator to choose one of five different languages offered, and to select from four different pressure-reading scales (mbar, kpa “H2O and mmH2O). The clogging level can be seen on a numerical and/or graphic scale. The pre-coating deactivation function, the recognition of the valves connected and the postwashing function are all completely automatic. What makes this “E” Series totally innovative is the software installed in the powerful microprocessor, which directs the full-automatic operation. This mode makes the instrument completely autonomous and independent in the management of the filter washing, modulating the pause and shooting time depending on the clogging level. The ”cleaning”, then, is increased or reduced automatically depending on the real needs; this optimizes the economy of the entire system. )' DEVICE PERFORMANCES LCD Display with backlight and friendly menus in six languages Three modes of operation: manual, auto and full-auto mode to smart filter management Operating time in seconds and minutes with selectable range for any applications Four units selectable for differential pressure measures No selection jumpers required for the output voltages of the valves that is done automatically according to the positioning of the common of pulse valves in the terminal Multi-selectable power supply thought just one jumper located in the terminals compartment Post-cleaning function with selectable number of cycles up to 255 cycles Hours counter and pulses counter Up two programmable alarm relays Minimum differential pressure Maximum differential pressure Maximum current pulse valves dissipation Pulse Valves not working alarm Power down External input to start/stop cleaning from remote External input to start/stop cleaning from air tank sensor Automatic precoating functions 4-20mA output to remote dP pressure Zero crossing switching pulse valve Pulse valves manual activation Selection of pulse-jet cleaning systems or rotating nozzle with self-selection of optimal parameters Protection from current overload for device and pulse valves ECONOMISER FOR DEDUSTING PLANTS WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER E Series E CONNECTION LAYOUT VALVES Terminal 1 EV1 2 EV2 3 EV3 4 EV4 5 EV5 6 EV6 7 EV7 8 EV8 signal Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 Solenoid valve 4 Solenoid valve 5 Solenoid valve 6 Solenoid valve 7 Solenoid valve 8 Terminal 9 EV9 10 EV10 11 EV11 12 EV12 13 EV13 14 EV14 15 EV15 16 EV16 signal Solenoid valve 9 Solenoid valve 10 Solenoid valve 11 Solenoid valve 12 Solenoid valve 13 Solenoid valve 14 Solenoid valve 15 Solenoid valve 16 POWER Power Supply 230-115-24/50hz Terminal 30 L phase Terminal 33 N Neutral Terminal 31 PE Ground Power Supply 24 VDC Terminal 32 DC + Terminal 25 GND Negative Terminal 31 PE ground (internally connect to 25) The common of solenoid valves must be connected to the type of pilot according to the following table: Terminal 17 18 19 20 LEGEND 230V 115V 24DC 24AC Voltages 230VAC 50Hz 115VAC 50Hz 24VDC 24VAC 50Hz NOTE: THE TERMINAL 31 IS THE GROUND OF DEVICE AND PULSE VALVES ELECTRICAL CHARACTERISTICS Power Timing 230VAC ±10% 50 Hz 115VAC ±10% 50 Hz 24VAC ±10% 50 Hz 24VDC ±10% Output 24VAC (MAX 20VA @ Ton Max 5s) 24VDC (MAX 20W@ Ton Max 5s) 230VAC (MAX 20VA@ Ton=10s) 115VAC (MAX 20VA@ Ton=10s) Fuses 1 x 2 Ampere Working temperature -15°C÷50°C Storage temperature -20°C÷60°C Pause time 5 s ÷ 50 min Working time (air pulse) 50 ms ÷ 10 s (step 10 ms) Differential pressure Meter Range: 0 ÷ 10 KPa Maximum differential pressure: 50 kPa – 0.5 bar CE DIRECTIVES This product is compliant with the following directives: Machine Directive 2006/42/EC ‘Electromagnetic compatibility’ related to the European Standard EN61000-6-2:2005 class B of the rule EN61000-6-4:2001. Low Voltage Directive 2006/95/CE related to the European Standard EN60947-1:2004 )( ECONOMISER FOR DEDUSTING PLANTS WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER BA BA4 /BA8 / BA12 /BA16 Series - Multiple output voltage Up to 144 outputs available upon request with different enclosures DESCRIPTION Economiser for dedusting plant cleaning cycle with digital ∆P control. Microprocessor-operated device with electrical zero connected to ground which ensures high immunity to external interference and low field emissions. Max 1 output relay. Max 2 volt free digital inputs. BA4 BA8 BA12 BA16 to control to control to control to control 4 solenoid valves 8 solenoid valves 12 solenoid valves 16 solenoid valves TECHNICAL CHARACTERISTICS Standard supply voltage Supply voltage available upon request Output voltage Working temperature range Absorbed power Protection level Max no. of outputs Dimensions Material 230 VAC / 115 VAC 24 VAC / 24 VDC 230/115 / 24VAC - 24VDC -10°C ÷ +50°C 10 VA (Stand by) IP65 16 140x230x95 (BA4 - BA16) ABS / RAL 7035 STANDARD FEATURES Connect by rylsan tube 4/6 )) Manual selection of output number / solenoid valve Adjustable activation time per each output from 0.05 to 5 sec. Adjustable interval time between two activations from 1 to 999 sec. Short circuit output protection Manual activation of each single output Digital differential pressure control Differential pressure reading by internal transducer (max 10kPa) Maximum dP alarm with alarmed contact open and automatic reset Zero dP reading adjustment 10kPa dP reading full range Additional post-cleaning cycle after fan stop Cleaning cycle ON/OFF by volt free external contact Max 25W load power per each output Input and output selection by JP1, JP2 and JP3 jumpers on the board ECONOMISER FOR DEDUSTING PLANTS WITH DIGITAL ∆P CONTROL BY INTERNAL TRANSDUCER BA4 /BA8 / BA12 /BA16 Series - Multiple output voltage Up to 144 outputs available upon request with different enclosures BA WIRING DIAGRAM K1 5A/250V FUSE (See Table 1) D1a GROUND COMMON OUTPUT No. D6 SUPPLY VOLTAGE CUMULATIVE FAULT/ ALARM RELAY Contact close with supply voltage ON and no alarm FAN FAN SWITCH (Contact close = fan ON) NOTE D1a: put a wire at the clamps if not used with digital input enabled CLEANING CYCLE ON/OFF BY D6 EXTERNAL CONTACT (Contact close = cycle active) NOTE D6: put a wire at the clamps if not used with digital input enabled -P2 dP filter clean side +P1 dP filter dirty side EV1 EV3 EV2 EV5 EV4 EV7 EV6 EV9 EV7 EV11 EV10 EV13 EV12 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 10kPa max. 3 14 15 12 13 1 2 3 4 5 dP BA EV15 EV14 EV16 SOLENOID VALVE VOLTAGE (see the label on the device) Absorbed power 10 VA (Stand-by) + power EV. Terminal 2,5 mm 250 VAC/12A Working temperature range -10°C ÷ +50°C NOTE DC: With 24VDC supply voltage, the available output voltage decreases by 2V for internal timer voltage drop. Check the compatibility with the solenoid valves used. Do no connect any supply voltage pole to ground with 24VDC supply voltage. PARAMETER SETTING IN SET MODE In Run Mode press key C to enter the function menu F01 F02 F03 F04 F05 F06 F07 F08 F09 F10 F11 F12 F13 Digital input use Pulse time Time interval between events Number of outputs Cycles after fan stop Manual activation ∆P control Output voltage Zero ∆P adjustment ∆P threshold for cycle STOP ∆P threshold for cycle START Max ∆P alarm threshold Fan mode selection Key A = Access to the selected function Key B = Exit from Set Up Key C = Function selection 0 = included 1 = excluded 0,05 ÷ 5,00 sec 1 ÷ 999 sec (see B3x) 0 ÷ 16 0 ÷ 99 C = Selection A = Output activation 0 = excluded 1 = includedo 24V, 115V, 230V (see HV) 0,00 (see C8) 0,01 ÷ 9,99 kPa 0,01 ÷ 9,99 kPa 0,01 ÷ 9,99 kPa 0 = by contact 1= by ∆P reading Key A = Parameter decrement in Key B = Return to function menu Key C = Parameter increase in Set NOTE The device will automatically switch from Set Mode to Run Mode if no key is pressed for 5 minutes ALARM DESCRIPTION 3,00/H = Maximum ∆P alarm (Blinking display) example: E1/05 = 05 output overload (Blinking display) OPERATION CE DIRECTIVES When power is supplied, the cleaning cycle starts if all the conditions required for operation are present This product is compliant with the following directives: OFF -0‘P’ A01 ... --E Cycle stopped due to cleaning consent missing (D6 open) Cycle stopped due to fan OFF Cycle stopped due to low dP (Blinking display) No. of activated EV Cycles active after fan stop (Blinking points) Bar indicating pause time flow between events ∆P reading over 9.99kPa Key B Key C Alarm Reset Access to Set Up Machine Directive 2006/42/EC ‘Electromagnetic compatibility’ related to the European Standard EN61000-6-2:2005 class B of the rule EN61000-6-4:2001. Low Voltage Directive 2006/95/CE related to the European Standard EN60947-1:2004. )* SEQUENCER FOR DEDUSTING PLANTS S S Series Description These control instruments series “S” are among the most modern and complete available today on the market. They have been built to command membrane solenoids on dust removal filters. A large back lighted liquid crystal display clearly shows cleaning system status. It has a fast-flow setting menu with intuitive operation that allows the operator to choose one of six different languages offered. The recognition of the valves connected and the post-washing function are all automatic. What makes this “S” Series totally innovative is the software installed in the powerful microprocessor, which directs the full-automatic operation. DEVICE PERFORMANCES LCD Display with backlight and friendly menu in six languages Operating time in seconds and minutes with selectable range for any application No selection jumpers required for the voltages of the valve Multi-selectable power supply without removing the panel or the card from enclosures Post-cleaning function with selectable number of cycles up to 255 cycles Hours counter and pulses counter Up two programmable alarm relays Pilot not working alarm Power down External input to start/stop cleaning from remote External input to start/stop cleaning from air tank sensor Zero crossing switching pilot valves Pilot manual activation Selection of pulse-jet cleaning systems or rotating nozzle with self-selection of optimal parameters Protection from current overload for device and pilot valves *! SEQUENCER FOR DEDUSTING PLANTS S Series S CONNECTION LAYOUT VALVES Terminal 1 EV1 2 EV2 3 EV3 4 EV4 5 EV5 6 EV6 7 EV7 8 EV8 signal Solenoid valve 1 Solenoid valve 2 Solenoid valve 3 Solenoid valve 4 Solenoid valve 5 Solenoid valve 6 Solenoid valve 7 Solenoid valve 8 Terminal 9 EV9 10 EV10 11 EV11 12 EV12 13 EV13 14 EV14 15 EV15 16 EV16 signal Solenoid valve 9 Solenoid valve 10 Solenoid valve 11 Solenoid valve 12 Solenoid valve 13 Solenoid valve 14 Solenoid valve 15 Solenoid valve 16 POWER Power Supply 230-115-24/50hz Terminal 30 L phase Terminal 33 N Neutral Terminal 31 PE Ground Power Supply 24 VDC Terminal 32 DC + Terminal 25 GND Negative Terminal 31 PE ground (internally connect to 25) The common of solenoid valves must be connected to the type of pilot according to the following table: Terminal 17 18 19 20 LEGEND 230V 115V 24DC 24AC Voltages 230VAC 50Hz 115VAC 50Hz 24VDC 24VAC 50Hz NOTE: THE TERMINAL 31 IS THE GROUND OF DEVICE AND PULSE VALVES ELECTRICAL CHARACTERISTICS Power 230VAC ±10% 50 Hz 115VAC ±10% 50 Hz 24VAC ±10% 50 Hz 24VDC ±10% Output 24VAC (MAX 20VA @ Ton Max 5s) 24VDC (MAX 20W@ Ton Max 5s) 230VAC (MAX 20VA@ Ton=10s) 115VAC (MAX 20VA@ Ton=10s) Fuses 1 x 2 Ampere Working temperature -15°C÷50°C Storage temperature -20°C÷60°C Timing Pause time 5 s ÷ 50 min Working time (air pulse) 50 ms ÷ 10 s (step 10 ms) CE DIRECTIVES This product is compliant with the following directives: Machine Directive 2006/42/EC ‘Electromagnetic compatibility’ related to the European Standard EN61000-6-2:2005 class B of the rule EN61000-6-4:2001. Low Voltage Directive 2006/95/CE related to the European Standard EN60947-1:2004 *" SEQUENCER FOR DEDUSTING PLANTS PA PA4 /PA8 / PA12 /PA16 Series - Multiple output voltage Up to 144 outputs available upon request with different enclosures DESCRIPTION Sequencer for dedusting plant cleaning cycle. Microprocessor-operated device with electrical zero connected to ground which ensures high immunity to external interference and low field emissions. Max 1 output relay. Max 2 volt free digital inputs. PA4 PA8 PA12 PA16 to control to control to control to control 4 solenoid valves 8 solenoid valves 12 solenoid valves 16 solenoid valves TECHNICAL CHARACTERISTICS Standard supply voltage Supply voltage available upon request Output voltage Working temperature range Absorbed power Protection level Max no. of outputs Dimensions Dimensions Material 230 VAC / 115 VAC 24 VAC / 24 VDC 230/115 / 24VAC - 24VDC -10°C ÷ +50°C 10 VA (Stand by) IP65 16 140x170x95 (PA4 - PA8) 140x230x95 (PA12 - PA16) ABS / RAL 7035 STANDARD FEATURES Manual selection of output number / Autoselection Adjustable activation time per each output from 0.05 to 5 sec. Adjustable interval time between two activations from 1 to 999 sec. Short circuit output protection Manual activation of each single output Cleaning cycle ON/OFF with external pressure controller by volt free contact Additional post-cleaning cycle after fan stop Cleaning cycle ON/OFF by volt free external contact Max 25W load power per each output Input and output selection by JP1, JP2 and JP3 jumpers on the board *# SEQUENCER FOR DEDUSTING PLANTS PA4 /PA8 / PA12 /PA16 Series - Multiple output voltage Up to 144 outputs available upon request with different enclosures PA WIRING DIAGRAM K1 5A/250V GROUND COMMON OUTPUT No. C6/D6 EV1 EV3 EV2 EV5 EV4 EV7 EV6 EV9 EV7 EV11 EV10 EV13 EV12 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 (see set F07) 3 12 13 4 5 1 2 3 PA D1a 14 15 FUSE (See Table 1) EV15 EV14 EV16 SUPPLY VOLTAGE CUMULATIVE FAULT/ ALARM RELAY Contact close with supply voltage ON and no alarm SOLENOID VALVE VOLTAGE (see the label on the device) FAN FAN SWITCH (Contact close = fan ON) NOTE D1a: put a wire at the clamps if not used with digital input enabled CLEANING CYCLE ON/OFF BY D6 EXTERNAL CONTACT (Contact close = cycle active) NOTE C6/D6: put a wire at the clamps if not used with digital input enabled Absorbed power 10 VA (Stand-by) + power EV. Terminal 2,5 mm 2 250 VAC/12A Working temperature range -10°C ÷ +50°C NOTE DC: With 24VDC supply voltage, the available output voltage decreases by 2V for internal timer voltage drop. Check the compatibility with the solenoid valves used. Do no connect any supply voltage pole to ground with 24VDC supply voltage. PARAMETER SETTING IN SET MODE In Run Mode press key C to enter the function menu F01 F02 F03 F04 F05 F06 F07 F08 Digital input use Pulse time Interval time between events Number of outputs Cycles after fan stop Manual activation Digital input Output voltage Key A = Access to the selected function Key B = Exit from Set Up Key C = Function selection 0 = included 1 = excluded 0,05 ÷ 5,00 sec 1 ÷ 999 sec (see B3x) 0 ÷ 16 (seeB1b) 0 ÷ 99 C = Selection/ A = output activation 0 = C6, 1=D6 (see C6, D6) 24V, 115V, 230V (see HV) Key A = Parameter decrement in Set Key B = Return to function menu Key C = Parameter increase in Set NOTE The device will automatically switch from Set Mode to Run Mode if no key is pressed for 5 minutes ALARM DESCRIPTION 3,00/H= Maximum ∆P alarm (Blinking display) example: E1/05 = : E1/05=05 output overload (Blinking display) OPERATION When power is supplied, the cleaning cycle starts if all the conditions required for operation are present OFF -01,00/P A01 ... 1,23 E Key B Key C Cycle stopped due to cleaning consent missing (D6 open) Cycle stopped due to fan OFF Cycle stopped due to low dP (Blinking display) No. of activated EV Cycles active after fan stop (Blinking points) ∆P reading (kPa) ∆P reading over 9.99kPa Alarm Rest Access to Set Up CE DIRECTIVES This product is compliant with the following directives: Machine Directive 2006/42/EC ‘Electromagnetic compatibility’ related to the European Standard EN61000-6-2:2005 class B of the rule EN61000-6-4:2001. Low Voltage Directive 2006/95/CE related to the European Standard EN60947-1:2004. *$ DIGITAL DIFFERENTIAL PRESSURE CONTROLLER BY INTERNAL TRANSDUCER BPB BPB Series DESCRIPTION Digital differential pressure controller between two points with microprocessor. Maximum 2 output relays. TECHNICAL CHARACTERISTICS Standard supply voltage Supply voltage available upon request Operating temperature range Absorbed power Protection level Dimensions (mm) 230 VAC / 115 VAC 24 VAC / 24 VDC -10°C ÷ +50°C 5 VA IP65 180x130x75 STANDARD FEATURES Minimum (K2) and maximum (K1) ∆P alarms on separate relays Differential pressure reading by internal transducer (max 10kPa) Minimum ∆P alarm with alarmed contact open and automatic reset Maximum ∆P alarm with alarmed contact open and automatic reset Zero ∆P reading adjustment PARAMETER SETTING IN SET MODE In Run Mode press key C to enter the function menu F01 Zero ∆P adjustment F02 Min. ∆P alarm threshold F03 Max ∆P alarm threshold Key A = Access to the selected function Key B = Exit from Set Up Key C = Function selection 0,00 (see C8) 0,01 ÷ 9,99 kPa (E=disabled) 0,01 ÷ 9,99 kPa Key A = Parameter decrement in Set Key B = Return to function menu Key C = Parameter increase in Set NOTE: The device will automatically switch from Set Mode to Run Mode if no key is pressed for 5 minutes OPERATION When power is supplied, dP control starts immediately 1,23 E Key B Key C ∆P reading (kPa) ∆P reading over 9.99kPa Alarm reset Access to Set Up K1 K2 5A/250V 5A/250V FUSE 250V / 500 mA (5x20) BPB P 4-20 mA P reading (0.00 kPa+C13 x = 4+20 mA) Supply by ECO12VDC max 450 Ohm (Connect to other devices by passive input and preferably insulated) 2 Terminal 2,5 mm 250 VAC/12A Working temperature range -10°C ÷ +50°C P filter clean side P filter dirty side +P1 MIN P ALARM RELAY (Contact close with supply voltage ON and no alarm) *% C11a +P2 MAX P ALARM RELAY (Contact close with supply voltage ON and no alarm) 3,00/H Max dP alarm (Blinking display) 0,50/L Min ∆P alarm (Blinking display) Absorbed power 10 VA (Stand-by) + power EV 10kPa max SUPPLY VOLTAGE (see the label on the device) ALARM DESCRIPTION WIRING DIAGRAM ELECTRONIC SINGLE TIMER TCONTEMP TECHNICAL CHARACTERISTICS Interval time Activation time Manual adjustment Supply voltage range Current consumption Working temperature Protection level Enclosure material Connection type Indicators Standard design 0,5 to 45 minutes, adjustable 20 to 300 ms, adjustable by micro-switch 24 to 240 VAC/DC 50/60Hz 4 mA max -40°C ÷ +60°C IP65 ABS plastic FR grade EN175301-803 (ex DIN 43650A) ON/OFF indication by LEDs VDE 01 10C *& TURBONET BUS SYSTEM CONTROLS - Up to 144 Valves Connection to master controller by a single 3-core cable TurboNet master controller has been designed to control cleaning cycle in dust collector filter applications. It features digital differential pressure control by internal transducer and provides effective cost reduction in electrical wiring procedures. It is a microprocessor operated system with electrical zero connected to ground which ensures high immunity to external interference and low field emissions. Max 2 output relays and 2 volt free digital inputs. TECHNICAL CHARACTERISTICS T-RCP Series Fluid Operating pressure Temperature range Base and cover Core tube Plunger Screws Coil insulation Protection Standar voltage Filtered and oilfree compressed air Min 0,5 bar - max 7,5 bar -20°C +80°C Die cast aluminium Stainless steel Stainless steel Stainless steel Class H IP66 24V DC MASTER WITH ∆P CONTROLLER Master generator 3 Wires cables Enclosure Dimensions (mm) Temperature Power inlet Power outlet One time Off time ∆P IP65 160x137x103 -10°C +70°C 110/220 AC 24DC 0,05 ÷5 sec 1 ÷ 999 sec 10kPa T- RCP Pilot box End cycle cleaning Hour counter Display multilanguage Set start / Stop cleaning cycle Alarm max ∆P *' MATRIX MATRIX WIRING WIRING SYSTEM SYSTEM Matrix System is designed to reduce time and cost of wiring installation. Matrix require a simple connection to the sequencer and to pulse valve. FEATURES Matrix consist in moulded prewired connectors for pulse valve Turbo provide Matrix connectors with desired pitch between valves. Is compatible with any sequence controller available from the market. Matrix can be supplied factory plugged to pulse valves on the header tank TECHNICAL CHARACTERISTICS Connectors Cable diameter Protection Temperature range Up to 12 per single belt 8 mm IP65 -20°C / +80°C HOW TO ORDER MATRIX 4 P200 M3 Plugged No.° of Connectors Pitch (mm) Conduit lenght to sequencer Terminal: •plugged •free wires 97 DUST EMISSION PROBE TC TC Series DESCRIPTION The TC probe surveys the passage of particles present in the gas, converting this physical phenomenon in an electric signal proportional to the dustiness degree. By comparing the signal generated by TC with preset thresholds in proper devices, it is possible to activate an alarm at the desired value. If the cause of the alarm is due to a broken bag, this can be identified if it is connected to proper devices belonging to ECO series which are envisaged for this kind of control. TECHNICAL FEATURES Power supply supply voltage Output signal Maximum load Gas temperature Operating temperature Relative humidity Housing degree protections *) 16 ÷ 24 VDC 100mA 4 ÷ 20mA activ 350 Ohm 120°C (standard) -10° ÷ +50°C 80% IP65 DUST EMISSION PROBE CONTROLLER DTC Series DTC DESCRIPTION Device designed to show and check the signal from Tribo-Electric probe to measure the quantity of dust in a duct with gas flow. TECHNICAL FEATURES Emission control by connecting a Tribo-Check Probe High emission pre-alarm with relay contact open in alarm and automatic reset High emission alarm with relay contact open in alarm and automatic reset TC Probe signal zero adjust Emission value set in mg/m3 TC Probe reading meaning time TC Probe signal reading in mA Double terminal on the board 2,5 mm2 250V 12A Multi language display OPTIONS ON REQUEST Cable glands type & Q.ty on request Other enclosures available on request ** ISO 9001:2008 certificated NOTE ™ DVcSRe`Z 4VceZWZTReZ GR]g`]VR >V^ScR_R aVcWZ]ecZUVa`]gVcRe`cZ DZdeV^ZV]Veec`_ZTZ aVcWZ]ecZUVa`]gVcRe`cZ aVcWZ]ecZUVa`]gVcRe`cZ ® TURBO srl via Po, 33 20811 CESANO MADERNO MB (ITALY) phone ++39 0362 574024 fax ++39 0362 574092 [email protected] www.turbocontrols.it ©- All rights reserved. Design and specifications are subject to change without notice CAT.HT_VALV 10/011 engl ®
Similar documents
refrigerators/freezers - sfsi
Accessories for ScienTempTM chest freezers include the Sonalarm Signal System, 6" Temperature Recorder, and Recorder Charts. The Sonalarm system monitors temperature rise and power failure of chest...
More information1. Sanitaryware_16.indd - Sussex Plumbing Supplies
H/L Cistern Pipe and Cistern Pack (inc. flush pipe, chain pull, buffer clip, fulcrum arm and siamp cistern fittings)
More informationsanitaryware sanitaryware traditional traditional
H/L Pan (excl. seat) H/L Cistern Pipe and Cistern Pack (inc. flush pipe, chain pull, buffer clip, fulcrum arm and siamp cistern fittings)
More informationbangalore development authority
CHANGE OF LAND USE FROM RESIDENTIAL TO COMMERCIAL USE AT SITE NO-2/5 OF YADIYUR VILLAGE INF/O SRI. D M GURUDESH CHANGE OF LAND USE AT SITE NO-67/2 OF SATHNUR VILLAGE JALA HOBLI INF/O KOUSTUBH DOKA ...
More information