Reusable Electrodes - makro-med

Transcription

Reusable Electrodes - makro-med
Patented
Radiofrequency
TECHNOLOGY
High Frequency – Low Temperature
Surgical Energy Source
Dermatology
Family Practice
General Surgery
Gynecology
Ophthalmology / Oculoplastics
Oral / Maxillofacial Surgery
Otorhinolaryngology / Facial Plastics
Plastic Reconstructive & Aesthetic Surgery
Proctology
®
RF ENERGY SOURCES &
ACCESSORY PRODUCTS
Proven in Hospitals, Universites, Surgi Centers,
Ambulatory/Outpatient Clinics and Offices Worldwide.
Established in 1955
Radiosurgical Energy Sources
4
Five Distinct Waveforms
4
Surgitron 4.0 MHz Dual RF
5
Surgitron Radiolase I
6
Surgitron Radiolase II
7
Surgitron FFPF EMC
8
®
®
®
®
®
®
9
Radiosurgical Accessories
Neutral Plates
9
Footswitches
10
Cables
11
Adaptors
12
EMC Device Accessories
13
Handpieces
15
Bipolar Forceps
17
Bayonet Bipolar Forceps
19
ACe-Tip
20
Non-Stick Forceps
TM
RF SurgiPens
22
23
RF Electrodes
Sterile/Single-Use Electrodes
24
Empire microIncision
25
®
TM
Needles
Reusable Electrodes
ACe-Tip
TM
27
Electrodes
Reusable Electrode/ACe-Tip
32
TM
Sets
Electrode Accessories
33
35
Educational Materials
36
Compact Disks
36
Patient Education Brochures
36
Textbooks
36
Smoke Evacuation System
Accessories
37
38
Multi Specialty Accessories
39
Otorhinolaryngology
41
General Surgery/Proctology
48
Gynecology
49
Plastic Surgery
51
Dermatology
53
Radiage /Cosmetic Rejuvenation
54
Ophthalmology/Oculoplastics
56
Family Practice/Podiatry
58
TM
3
RADIOSURGICAL ENERGY SOURCES
5 Distinct Waveforms
Surgitron® Dual RF
technology has received
*IEC3A-S30
IEC-PC (for 110v) power cord
IEC-PC (for 220v) power cord
worldwide acclaim and
• Micro-smooth cutting
• Negligible lateral heat
• Minimal cellular
destruction
• Ideal for skin incision
recognition from leading
and biopsy
• Best cosmetic results
Shipped complete with:
surgeons, clinics,
• Fastest healing
IEC-PC
IEC Power Cord
DF-FSC
Dual Footswitch
& Cable
IEC3A-SL1
Instruction Manual
Fully Rectified
ellman
universities and authors.
Absorption Comparison of Other Surgical Energy Sources
IEC-HP1
IEC Foot-Controlled
Handpiece
• Cutting with hemostasis
• Ideal for subcutaneous
IEC-3FHPB
IEC 3-Button
Fingerswitch
Handpiece
Surgitron® Dual RF/120 IEC
H79
Handpiece Clip
• Especially useful in
vascular areas while
tissue dissection and
producing minimal
High Frequency — Low Temperature
VCD/PC5IEC3 Instructional CD ROM
planing.
amounts of lateral heat
RF Energy Source
IEC-BC/I
3- Bipolar
Sterile/Single-Use
Cables
The patented Surgitron® Dual RF energy source represents the most advanced radiowave
technology that provides unparalleled surgical control, precision, versatility and safety.
The high frequency of the Dual RF minimizes heat dissipation and thus cellular alteration.
Clinical benefits include reduced post-operative discomfort, minimal scar tissue formation,
maximum readability of histologic specimen, enhanced healing and excellent cosmetic results.
IEC-NPC
IEC Neutral Plate
and tissue damage
Partially Rectified
The ellman® radiowave energy
• Coagulation / Shrinkage
• For hemostatic control
• Hemostasis with
controlled penetration
source represents advanced
Fulguration
ellm
radiowave technology that
provides unparalleled surgical
IEC-3FHPB/D1 Sterile/Single-Use
3-Button Fingerswitch
Handpiece
DSEP40
40 Medical Electrodes
Assortment Package
Sterile/Single-Use
“J” Series Bipolar
Forceps (Item number
determined by
selection) see page
14 & 15
control, precision, versatility
and safety. Clinical benefits
• Maximum penetration
4
Patented Surgitron® 4.0 MHz
Dual RF/120 IEC
ellman’s radiofrequency
ellm
an
1
2
3
4
5
Fully Filtered
ellman
RADIOSURGICAL ENERGY SOURCES
and hemostasis
• Ideal for intentional
include reduced post-operative
tissue destruction
discomfort, minimal
scar tissue formation,
Bipolar/Wet Field
Coagulation
enhanced healing and
• Pinpoint, micro-coagulation
excellent cosmetic results.
• No tissue adherence to
forceps
• No charring or tissue
necrosis
• Ideal for coagulation in and
*(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ)
around critical anatomy
• Wet field coagulation
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
5
RADIOSURGICAL ENERGY SOURCES
RADIOSURGICAL ENERGY SOURCES
Surgitron® Radiolase® I
Surgitron® Radiolase® II
Surgitron® Radiolase® I Radiosurgical
High Frequency — Low Temperature
6
Patented Surgitron®
Radiolase® I
Patented Surgitron®
Radiolase® II
*Item #RL-S50A
*Item #RL2-S50
Shipped complete with:
Shipped complete with:
IEC-HP1
IEC-HP1
IEC-NPC
Foot-Controlled
Handpiece
Neutral Plate
Foot-Controlled
Handpiece with
Locking Chuck
RL-SL1
Operation Manual
IEC-NPC
Neutral Plate
VCD/PC5RRL Video
RL2-L1
Operation Manual
RL-FSC
Footswitch
RL2-FSC
Dual Footswitch
H79
Clip
IEC-1FHPA
IEC-1FHPA
One-Button
Fingerswitch
Handpiece
One-Button
Fingerswitch
Handpiece
IEC-BC/I
Bipolar Cable
IEC-PC110
(for 110v) Power Cord
IEC-PC110
(for 110v) Power Cord
IEC-PC220
(for 220v) Power Cord
IEC-PC220
(for 220v) Power Cord
DSEP40
7 Medical
Assortment Package
Sterile/Single-Use
DSEP40
40 Medical Electrode
Assortment Package
Sterile/Single-Use
“J” Series Bipolar
Forceps (Item
number determined
by selection) see
page 14 & 15
Surgitron® Radiolase® II Radiosurgical
High Frequency — Low Temperature
Surgical Energy Source
Surgical Energy Source
•Maximize hemorrhage control
•Planing of soft tissue unique to radiosurgery
•Bacterial free incisions
•Pressureless incisions
•Reduced operating time
There is no further need to debate the virtues of monopolar versus bipolar technology
for minor surgery. The ellman® Radiolase® II affords surgeons the ability to utilize both
monopolar and bipolar modalities at, the frequency scientifically and clinically proven
to produce the least amount of lateral heat and tissue alteration.
This technology goes beyond the laser and beyond bipolar in terms of tissue
preservation and safety, all at a very affordable price.
*(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ)
*(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ)
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
7
RADIOSURGICAL ENERGY SOURCES
RADIOSURGICAL ACCESSORIES
Surgitron® FFPF EMC
Neutral Plates
Patented Surgitron® FFPF EMC
Device
Surgitron® FFPF EMC
*Item# EMC 110A (for 110v) Power Cord
*Item# EMC 220A (for 220v) Power Cord
IEC Neutral Plate
Shipped complete with:
Reusable, coated
For Dual RF and Radiolase® Devices
(1 pc)
HP1
Foot-Controlled
Handpiece with
Locking Chuck
H4
EMC Neutral Plate
*PC
DSEP40
EMC Power Cord
40 Medical Electrode
Assortment Package
Sterile/Single-Use
EMCL1
Operating Manual
H79
Handpiece Clip
H66
Electrode Protector
Stand
DVD/EMC1
Instructional Video
IEC-NPC
With the ellman ®
Reusable Neutral Plate,
no skin contact required.
IEC Disposable Neutral Plate Standard Size
IEC-NPD
Single-Use
For Dual RF and Radiolase® Devices
(25 pcs)
High Frequency — Low Temperature
Surgical Energy Source
The ellman® Sterile/Single-Use
• Minimal Tissue Alteration
• No Burning or Charring of the Tissue
• Bacteria-Free Incisions
• Reduced Surgical Time
• Improved Visibility of Operative Field
• Maximized Hemorrhage Control
• Pinpoint Coagulation
Neutral Plate is a sensing,
pre-gelled, self-adhering,
dispersive pad. The effective
IEC Disposable Neutral Plate Small Size
IEC-NPD-S
electrodes are two aluminum
Single-Use
For Dual RF and Radiolase® Devices
(25 pcs)
oil conductors, covered by a
hydrogel conductive adhesive.
The conductive hydrogel
provides a low-current density
return path from the patient to
the RF Device while the two
EMC Neutral Plate
foils provide a means of sens-
H4
ing contact quality.
Reusable, coated
For the EMC Device
(1 pc)
*(Specify voltage/country specific plug available 110-220V, EU, UA, ANZ)
8
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
9
RADIOSURGICAL ACCESSORIES
RADIOSURGICAL ACCESSORIES
Footswitches
Cables
Bipolar Cable
IEC-JX/B
Dual Frequency Footswitch and Cable
DF-FSC
Reusable
For use with Surgitron® Dual RF or Radiolase® II Devices (1 pc)
For Surgitron® Dual RF Device
(1 pc)
IEC-BC
Sterile/Single-Use
Minor Surgery Bipolar cable
For use with Surgitron® Dual RF or Radiolase® Devices (5 pcs)
Single-Action Bipolar Footswitch and Cable
DF-FSC/3
JX/E
For Surgitron® Dual RF Device
(1 pc)
Reusable
For use with EMC Device (1 pc)
Quick-Connect™ Cable
Radiolase Footswitch and Cable
RL-FSC
For Surgitron® Radiolase® I Device
(1 pc)
For use with SurgiPen™ Suction Tonsil and Suction Adenoid Probes,
Disposable Suction Coagulator, Mono Stan RF Forceps,
Rodin™ Micro Surgery handpiece, Micro Fibre® Electrode.
IEC-SP020
Reusable
For use with Surgitron® Dual RF or Radiolase ® II Device (1 pc)
SP020
Dual Monopolar/Bipolar Footswitch
RL2-FSC
Reusable
For use with EMC Device (1 pc)
For Surgitron® Radiolase® II Device
(1 pc)
Snare Cable
For use with Polyp Snare™
IEC-H7B
Reusable
For use with Surgitron® Dual RF or Radiolase® II Device (1 pc)
H7B
Pneumatic Footswitch
SVFSC
For use with Surg-e-Vac™
Smoke Evacuation System
(1 pc)
Reusable
For use with EMC Device (1 pc)
Lap/Endo Monopolar Cable
IEC-UC
Reusable
For use with Surgitron® Dual RF or Radiolase® II Device (1 pc)
Monopolar cable for Endoscopic instruments
10
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
11
RADIOSURGICAL ACCESSORIES
RADIOSURGICAL ACCESSORIES
Adaptors
Adapters for Surgitron® EMC
Field Battery Adaptor Kit
FK101
Includes: Adaptor, Inverter and
Cables
The Field Battery Adaptor is
designed to operate with the
ellman® line of radiosurgical
Universal Fingerswitch Adapter
EMC-KA
Reusable
For use with EMC Device, handpiece not included
(1 pc)
The ellman® Universal
Fingerswitch Adapter plugs
into the side of your
devices only. The purpose is
Surgitron® FFPF EMC.
to allow the operation of the
The adaptor eliminates the
radiosurgical device with a
“disappearing” foot pedal.
12-volt automotive
The standard foot-controled
battery when there is no
handpiece is still
primary AC power available.
operational.
Fingerswitch Handpiece
XKO6C
Surg-e-Doc
Reusable
For use with EMC Universal Fingerswitch Adapter
(2 pcs)
SDS30
The Surg-e-Doc offers the surgeon the ability to utilize an extra monoplar port thereby having two
handpieces available at the surgical site. This reduces the need to frequently change
electrodes in a single handpiece.
EMC Universal
Fingerswitch Plug
The Surg-e-Doc also provides for automatic activation/deactivation of the ellman® Surg-e-Vac™
smoke evacuation system thereby eliminating the need for an additional footpedal in the
surgical/treatment room.
12
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
13
RADIOSURGICAL ACCESSORIES
RADIOSURGICAL ACCESSORIES
For Surgitron® EMC
Handpieces
Steri Caps™ enable you to
EMC Steri Caps™
EMC-H35
Reusable
Steri CapTM (3 for large dial and
3 for small dial) for use with
EMC only, 3-Blue and 3-Black
(6 pcs)
control in total sterility with
Magnified view
autoclavable protective
dial covers.
3-Button Fingerswitch Handpiece with Locking Chuck
IEC-X3FHPB
Reusable
Accepts 1/16" and 3/32” Shaft Electrodes (2 pcs)
For Surgitron® Dual RF
The ellman® handpiece is
ergonomicaly designed to fit
comfortably in your hand
therefore maximizing
productivity by reducing
Sterile 3-Button Fingerswitch Handpiece with Locking Chuck
Bipolar Converter™
EMC-H95A
For use with EMC Device
(1 pc)
The Bipolar ConverterTM
IEC-3FHPB/D
operator fatigue and
provides the surgeon the
Sterile/Single-Use
Accepts 1/16" and 3/32” Shaft Electrodes, (10 pcs)
For Surgitron® Dual RF
discomfort.
convenience of switching the
ellman® Surgitron® EMC from
the Handpiece / Antenna Plate
monopolar mode to the Bipolar
3-Button Fingerswitch Blade Handpiece with Locking Chuck
IEC-XBHP3
Forceps mode with the simple
Bipolar Converter
Steri Caps™
H96
Caps for activation switch
for use with Bipolar Converter™
(3 pcs)
flick of a switch. This eliminates
the need to plug and unplug
the cords during surgery.
The Wall Bracket space
saving accessory attaches
easily to any vertical surface.
Wall Bracket
Reusable
Accepts Sterile/Single-Use Blades (assorted surgical blades including #10, and #15)
and 1/16" Electrode (2 pcs)
For Surgitron® Dual RF
Sterile 3-Button Fingerswitch Blade Handpiece with Locking Chuck
IEC-BHP3/D
Sterile/Single-Use
Accepts Sterile/Single-Use Blades and 1/16” Electrodes, (10 pcs)
For Surgitron® Dual RF
The ellman® Wall Bracket will
HH
Wall Bracket with hardware.
For use with EMC only
Swivel arm and
swivel plate.r
(1 pc)
support up to 40 lbs. and is
ideal for the Surgitron® EMC.
2-Button Fingerswitch Handpiece with Locking Chuck
XKO6C
Reusable
Accepts 1/16" and 3/32” Shaft Electrodes (2 pcs)
For Surgitron® EMC Device
14
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
15
RADIOSURGICAL ACCESSORIES
RADIOSURGICAL ACCESSORIES
Handpieces
Bipolar Forceps
ellman® Bipolar Forceps
provides clean wet-field
One-Button Fingerswitch Handpiece
coagulation.
IEC-1FHPA
Reusable
Accepts 1/16" and 3/32" shaft electrodes (2 pcs)
One button fingerswitch handpiece for Radiolase® Devices
J1
Length 9.5cm, 0.4mm, Straight Tip
J1B
Length 9.5cm, 0.4mm, Bent Tip
J2
Length 9.5cm, 0.3mm, Curved Flat/Angled Tip
microInsulated Needle Handpiece with Locking Chuck
IEC-XH136 – For Surgitron® 4.0 Dual RF and Radiolase® II Devices (2 pcs)
XH136 – For Surgitron® EMC Device (2 pcs)
Reusable. Smaller orifice for insertion of ellman ® microInsulated needles only.
Included in Cosmetic Treatment package (1 pc)
Recent forceps modification of
Blade Handpiece with Locking Chuck
IEC-H15 – For Surgitron® Dual RF and Radiolase® Devices, accepts 1/16” Shaft
H15 – For Surgitron® EMC Device, accepts 1/16” Shaft
IEC-QH15 – Accepts 3/32” Shaft. For Surgitron® Dual RF
QH15 – Accepts 3/32” Shaft. For Surgitron® EMC
Surgitron ® EMC
(Monopolar)
the ellman® radiosurgical
bipolar accessories developed
some years ago, now make
J3
Length 7.8cm, 0.4mm, Angled Tip
Reusable. Foot Pedal activation (2 pcs)
For use with assorted surgical blades including #10, and #15
simultaneous cutting and
coagulation extremely easy.
With the added safety of low
wattage, there is no collateral
Foot-Controlled Handpiece with Locking Chuck
IEC-XHP1 – For Surgitron® Dual RF and Radiolase® Devices
XHP1 – For Surgitron® EMC Device
Surgitron ® Dual RF and
Radiolase ® (Monopolar)
J4
Length 7.8cm, 0.3mm, Straight Tip
visualization is greatly
Reusable. Accepts 1/16" and 3/32" shaft (2 pcs)
improved. Furthermore, there
Separate plugs are used in
is no possibility of unintended
accordance with the
corresponding device, the
thermal damage and direct
J5
Length 9.2cm, 0.3mm, Bent Tip
J8
Length 16.3cm, 1.0mm, Straight Tip
or offsite burns.
Rodin™ Microsurgery Handpiece
16
XRHP – Length (3.895”) 98.93mm, Width (.460”) 11.68mm
Surgitron® Dual RF, Radiolase ®
Reusable. To be used with IEC Quick-Connect™Cable
For Surgitron® Dual RF and Radiolase® Devices, accepts 1/16” Shaft (2 pcs)
(See page 11z for Quick-Connect™ Cable, Cat. No. IEC-SP020)
(See page 32 for Rodin™ Microsurgery ACe-Tip™ Electrode Set, Cat. No. RACE7)
RODIN™1
Rodin™ RF Microsurgery Set
One RHP Rodin™ Microsurgery Handpiece, one IEC-SP020 Quick-Connect™ Cable,
one RACE7 Rodin™ Microsurgery ACe-Tip™ Set, and instructions for use.
and the Surgitron® EMC.
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
17
RADIOSURGICAL ACCESSORIES
RADIOSURGICAL ACCESSORIES
Bipolar Forceps
Bayonet Bipolar Forceps
J9
Length 16.2cm, 1.0mm, Straight Tip
J7
Length 17.3cm, Tip Wide 1.0mm, Bayonet, Flat Tip
J7U
Length 17.3cm, Tip Wide 1.0mm, Bayonet, 45° Up, Flat Tip
J7D
Length 17.3cm, Tip Wide 1.0mm, Bayonet, 45° Down Flat Tip
EMC Bipolar Cord
(see page 8)
J10
Length 16.2cm, 2.0mm, Straight Tip
ellman® Bayonet Bipolar
J13
Length 15.6cm, Tip Wide 1.0mm, Bayonet, non-stick epistaxis, Serrated Tip
Forceps enhance access to
the surgical environment
J11
Length 12.2cm, 0.4mm, Straight Tip
for increased visibility
during all radiosurgical
Surgitron ® Dual RF and
Radiolase ® Bipolar Cord
J12
J14
J19
18
Length 10.9cm, 1.0mm, Straight Tip
J17
Length 17.9cm, Tip Wide 1.0mm, Bayonet, external tip insulated
J18
Length 16.9cm, Tip Wide 0.5mm, Bayonet
J20
Length 16.6cm, Tip Wide 2.0mm, Bayonet
J21
Length 19.7cm, Tip Wide 1.0mm, Bayonet
procedures.
(see page 8)
Length 10.8cm, 0.7mm, Straight Tip
Length 13.6cm, 2.0mm, Straight Tip
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
19
RADIOSURGICAL ACCESSORIES
RADIOSURGICAL ACCESSORIES
ACe-Tip Non-Stick Forceps
ACe-Tip Non-Stick Forceps
TM
TM
Featuring Advanced Composition Alloy “Non-Stick”, Low Temperature
Featuring Advanced Composition Alloy “Non-Stick”, Low Temperature
ACe-Tip™ Technology Advantages:
• Non-Adherent
• Improved Surgical Outcomes
ACBF-010
Length (3.5”), 8.89cm, 0.5mm, Straight
ACBF-015
Length (7.0”), 17.18cm, 0.7mm, Straight
ACBF-016
Length (7.0”), 17.18cm, 1.2mm, Straight
ACBF-017
Length (7.0”), 17.18cm, 1.5mm, Straight
• Minimal Absorption
Magnified view
Magnified view
• Tissue Preservation
ACBF-011
Length (3.5”), 8.89cm, 0.5mm, Bent
Magnified view
Magnified view
Adherence Free
ACBF-012
Length (4.5”), 11.43cm, 0.5mm, Straight
Magnified view
Magnified view
ACBF-013
Length (5.5”), 14.00cm, 0.5mm, Straight
Magnified view
ACBF-014
Magnified view
ACBF-021
Length (6.5”), 16.51cm, 1.0mm, Bayonet, Serated Tip
Magnified view
ACBF-022
Length (7.25”), 18.52cm, 1.0mm, Bayonet
Length (6.25”), 15.88cm, 1.0mm, Straight
Magnified view
20
ACe-Tip™ Non-Stick Bipolar
Forceps clinical photos
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
21
RADIOSURGICAL ACCESSORIES
RF ELECTRODES
RF SurgiPen™
Electrodes
(3/32”)
2.4mm
SP010
# 4 Curette, 4mm
Sterile/Single-Use, (15 pcs)
SP011
# 7 Curette, 7mm
Sterile/Single-Use, (15 pcs)
(1/16”)
1.6mm
The Patented RF SurgiPen™
can be energized with high
radiofrequency waveforms,
Proximal shaft diameter is
Proximal Shaft Diameter
available in 3/32" or 1/16"
(2.4mm or 1.6mm) to
Fine - Used when minimal tissue alteration is desired
accommodate standard
Regular - Used to produce more coagulation
handpiece connection.
or used as a standard
instrument.
SP012
Ball
Sterile/Single-Use, (15 pcs)
Most surgical specialties
will benefit from the use of
this line of unique
SP013
Loop
Sterile/Single-Use, (15 pcs)
instruments due to their
ABOUT
ellman® Electrodes:
All ellman® electrodes are frequency-matched to the ellman® energy source for
minimal tissue alteration. The insulated shaft of most electrodes can be bent or
contoured for all surgical procedures.
precision and versatility.
SP014
Needle
Sterile/Single-Use, (15 pcs)
SurgiPen’s™ ergonomic
handle design is composed
INFORMATION
Regarding Ordering Electrodes:
of lightweight material for
SP015
# 15 Scalpel
Sterile/Single-Use, (15 pcs)
fatigue-free manipulation.
Code To Electrode Suffixes:
B- Bendable
D- Disposable (Sterile/Single-Use)
Code To Electrode Prefixes:
T- Package of (2 pcs)
X- Package of (5 pcs)
SP016
Round Blade
Sterile/Single-Use, (15 pcs)
SP017
Vari-Tip™
Sterile/Single-Use, (15 pcs)
Most electrodes are available in 1/16” or 3/32” shaft sizes.
Use “Q” as a prefix when ordering 3/32” shaft size, i.e. QTA8B
Longer electrode shaft sizes are available.
Contact ellman’s sales representatives for more details.
Quick-Connect™ Cable
IEC-SP020
RF SurgiPen™ to be used with the Quick-Connect™ Cable.
See page 11 for more information.
22
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
23
RF ELECTRODES
RF ELECTRODES
Sterile/Single-Use
Empire® microlncision™ Needles
The ellman® Empire®
microIncision™ Needle
Empire microlncision™ Needle Electrodes
Medical Electrode Set
ellman® Sterile/Single-Use
DSEP40
RF electrodes are the latest
Sterile/Single-Use
Assortment of 8 styles, Sterile/Single-Use
RF electrodes, available in 1/16” Shaft Only (40 pcs)
Includes 5 of each electrode:
A2D, A8D, B1D, B2D, C3D, D8D, E3D, F1D
advance in Radiosurgery.
They are regarded as the
safest cutting electrodes
One Style Sterile/Single-Use Electrodes
available by doctors
Available in 1/16” Shaft Only (25 pcs per pack)
A2D
A3D/OS
A8D
Vari-Tip™ Wire Electrode
Adjustable cutting wire
B2D
Round Loop Electrode
1/4” Dia.
Round Loop Electrode
3/8” Dia.
C3D
Diamond Loop Electrode
3/16” Dia.
D8D
Ball Electrode
2.3 mm
E3D
Scalpel Electrode
1” Length
E4D
Scalpel Electrode
1/2” Length
TEE301
Length 2cm, straight
TEE302
Length 3cm, straight
TEE303
Length 4cm, straight
High Frequency Radiowave
energy to accomplish
cell-specific interaction and
produce optimum results,
while reducing post-operative
scarring and promoting
TEE304
90° angle
faster healing.
The ellman® Sterile/Single-Use
TEE305
45° angle
Empire® microIncision™
RF electrode eliminates the
risk of cross contamination
as well as ensuring patient
confidence.
B1D
Magnified view
for all Empire
microlncision™
worldwide.
Fine Wire Electrode
3/8” Length
Needle Electrode
3/4” Length
Electrodes deliver focused
Sterile/Single-Use, available in 1/16” or 3/32” (2 per pack)
Use “Q” as a prefix when ordering 3/32” shaft size
Needle Electrodes are used for
TEE306
Length 3cm, 3mm 45° angle
TEE307
Length 2cm, 3mm 45° curved
precise cutting and coagulation
during radiosurgical procedures.
Proximal shaft diameter is
available in 3/32" or 1/16"
TEE308 1cm needle,
Length (4”), 10.10cm, straight sleeve
TEE309 1cm needle,
Length (5”), 12.70cm, straight sleeve
(2.4mm or 1.6mm) to
accommodate standard
handpiece connection.
TEE310 1cm needle,
Length (6”), 15.24cm, straight sleeve
Empire® microIncision™
TEE311 1cm needle,
Length (7”), 17.78cm, straight sleeve
in individual sterile packages
Needle Electrodes are supplied
of two, are Single-Use and
F1D
TEE312 1cm needle,
Length (4”), 3mm 45° angle, straight sleeve
should not be re-sterilized.
Broad Needle Electrode
TEE313 1cm needle,
Length (5”), 3mm 45° angle, straight sleeve
TEE314 1cm needle,
Length (6”), 3mm 45° angle, straight sleeve
TEE315 1cm needle,
Length (7”), 3mm 45° angle, straight sleeve
24
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
25
RF ELECTRODES
RF ELECTRODES
Empire® microlncision™ Needles
Reusable Electrodes
Empire microlncision™ Needle Electrodes
Needle Electrodes are
Needle Electrodes*
Sterile/Single-Use, available in 1/16” or 3/32” (2 per pack)
Use “Q” as a prefix when ordering 3/32” shaft size
Magnified view
for all Empire
microlncision™
Reusable
1/16” shaft size or 3/32” (2 pcs)
Use “Q” as a prefix when ordering 3/32” shaft size
TEE316 2cm needle,
Length (4”), 10.16cm, 45° angle, straight sleeve
TEE317 2cm needle,
Length (5”), 12.70cm, 45° angle, straight sleeve
TEE318 2cm needle,
Length (6”), 15.24cm, 45° angle, straight sleeve
primarily used for incisions
and excisions in precise
TA1B
Length 3/8", Super Fine Wire
TA2B
Length 3/8", Fine Wire
TA9B
Length 3/8", Regular Wire
TA3B
Length 3/8", Regular Needle
TF1B
TEE319 2cm needle,
Length (7”), 17.78cm, 45° angle, straight sleeve
TA8B
TEE320 1cm needle,
,Length (4”), 10.16cm, curved sleeve
Length 1/2”, Broad Needle
Vari-Tip™ Microdisection™ Needle
(comes with additional wire and has
an adjustable depth)
surgical procedures.
Choice of Wire Gauge
Fine - Used when
minimal tissue
alteration is desired
Regular - Used to
produce more
coagulation
TEE321 1cm needle,
Length (5”), 12.70cm, curved sleeve
Round Loop Electrodes
Round Loop Electrodes*
TEE322 1cm needle,
Length (6”), 15.24cm, curved sleeve
Reusable
1/16” shaft size or 3/32” (2 pcs)
Use “Q” as a prefix when ordering 3/32” shaft size
TEE323 1cm needle,
Length (7”), 17.78cm, curved sleeve
shaving lesions, contouring
TBBB
TEE324 Bayonet
5/32" Dia. Round Loop, Fine Wire
1/4" Dia. Round Loop, Fine Wire
1/4" Dia. Round Loop, Regular Wire
TEE325 1cm needle,
Length (2”), 5.08cm, curved sleeve
TB9B
TB10B
19/64" Dia. Round Loop, Fine Wire
19/64" Dia. Round Loop, Regular Wire
TEE326 1cm needle,
Length (1”), 2.54cm, curved sleeve
TB2B
TB5B
3/8" Dia. Round Loop, Fine Wire
3/8" Dia. Round Loop, Regular Wire
TEE327 1cm needle,
Length (3/4”), 1.91cm, straight
TB3B
TB6B
1/2" Dia. Round Loop, Fine Wire
1/2" Dia. Round Loop, Regular Wire
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
tissue and are excellent for
obtaining biopsy specimens.
TB1B
TB4B
TEE328 1cm needle,
Length (1”), 2.54cm, curved sleeve
26
are primarily used for
*Electrodes are displayed in actual size.
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
27
RF ELECTRODES
RF ELECTRODES
Reusable Electrodes
Reusable Electrodes
Diamond Loop Electrodes*
Reusable
1/16” shaft size or 3/32” (2 pcs)
Use “Q” as a prefix when ordering 3/32” shaft size
Diamond Loop Electrodes
Ball Electrodes*
are primarily used for
Reusable
1/16” shaft size or 3/32” (2 pcs)
Use “Q” as a prefix when ordering 3/32” shaft size
one-stroke elliptical incisions.
TC1B
TC4B
1/8" Diamond Loop, Fine Wire
1/8" Diamond Loop, Regular Wire
TC3B
TC6B
3/16" Diamond Loop, Fine Wire
3/16" Diamond Loop, Regular Wire
TC17B
TC18B
1/4" Diamond Loop, Fine Wire
1/4" Diamond Loop, Regular Wire
TC19B
TC20B
5/16" Diamond Loop, Fine Wire
5/16" Diamond Loop, Regular Wire
TC21B
TC22B
7/16" Diamond Loop, Fine Wire
7/16" Diamond Loop, Regular Wire
Reusable
1/16” shaft size or 3/32” (2 pcs)
Use “Q” as a prefix when ordering 3/32” shaft size
used for coagulation.
They seal superficial blood
TD3B
vessels reducing post2mm Ball
operative discomfort.
Triangle Loop Electrodes
Triangle Loop Electrodes*
Ball Electrodes are primarily
are primarily used for
TD8B
2.36mm Ball
TD9B
3.17mm Ball
TD10B
4.34mm Ball
TD11B
4.75mm Ball
Oval Loop Electrodes*
Oval Loop Electrodes are
Reusable
1/16” shaft size or 3/32” (2 pcs)
Use “Q” as a prefix when ordering 3/32” shaft size
primarily used for shaving
lesions and contouring
TP1B
TP2B
5/32" Oval Loop, Fine Wire
5/32" Oval Loop, Regular Wire
TP3B
TP4B
1/4" Oval Loop, Fine Wire
1/4" Oval Loop, Regular Wire
TP5B
TP6B
19/64" Oval Loop, Fine Wire
19/64" Oval Loop, Regular Wire
TP7B
TP8B
3/8" Oval Loop, Fine Wire
3/8" Oval Loop, Regular Wire
TP9B
TP10B
1/2" Oval Loop, Fine Wire
1/2" Oval Loop, Regular Wire
tissue.
shaving lesions and
TC9B
TC10B
5/32" Triangle Loop, Fine Wire
5/32" Triangle Loop, Regular Wire
TC7B
TC8B
1/4" Triangle Loop, Fine Wire
1/4" Triangle Loop, Regular Wire
TC11B
TC12B
19/64" Triangle Loop, Fine Wire
19/64" Triangle Loop, Regular Wire
TC13B
TC14B
3/8" Triangle Loop, Fine Wire
3/8" Triangle Loop, Regular Wire
TC15B
TC16B
1/2" Triangle Loop, Fine Wire
1/2" Triangle Loop, Regular Wire
contouring tissue.
*Electrodes are displayed in actual size.
28
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
29
RF ELECTRODES
RF ELECTRODES
Reusable Electrodes
Reusable Electrodes
Scalpel Electrode*s
Scalpel Electrodes are used
Javate Endoscopic DCR Electrodes*
The patented Javate
Reusable
1/16” shaft size or 3/32” (2 pcs)
Use “Q” as a prefix when ordering 3/32” shaft size
primarily for incisions and exci-
R6 Javate Endoscopic DCR Set of 7 Assorted Electrodes
Endoscopic DCR electrode
sion of tissue. The blade shape
TE1B
3/16” Scalpel, 45° Angle
R7S 7mm Short Exposure
Electrode (1 pc)
provides broader coagulation
R7L 7mm Long Exposure
than a needle electrode.
TE2B
eliminates cutaneous scars
and cosmetic blemishes
while shortening
Electrode (1 pc)
3/8” Scalpel
post-operative recovery
R9S 9mm Short Exposure
TE3B
1” Scalpel
Empire® MicroTip Needles are
Electrode (1 pc)
tapered and have a pinpoint
Empire® MicroTip Electrodes*
design which produces
Reusable
2mm exposed tip (2 pcs, one of each)
micro-smooth cutting and
time and pain.
R9L 9mm Long Exposure
Electrode (1 pc)
R11S 11mm Short Exposure
Electrode (1 pc)
coagulation while creating
R11L 11mm Long Exposure
TEE227 Empire MicroTip Needles
one .010 wire, one .020 wire
Insulated Coated Needle Set
Electrode (1 pc)
the least amount of tissue
alteration.
R12 9/64” Round Loop Exposure
Electrode (1 pc)
*Electrodes are displayed in actual size.
Insulated Needle Electrodes
Insulated Needle Electrodes™*
D7
Insulated Coated Needle Set
(3 pcs)
D6A
Fine Insulated Coated Needle
.004 Super Fine, White, (1 pc)
D6B
Fine Insulated Coated Needle
.007 Fine, Purple, (1 pc)
D6C
Fine Insulated Coated Needle
.009 Regular, Orange, (1 pc)
Reusable, 1/2mm exposed tip
are used for the treatment of
Telangiectasia and for epilation.
Radiosurgical Mucotome Electrodes*
H140
Radiosurgical Mucotome Electrode Set of 1/16” Shaft
Reusable
Set of 3 electrodes, includes H141, H142 & H143
Used for excision of mucosal strip
H141
Insulated Mucotome Electrode
8mm wide x 2mm depth (1 pc)
H142
Insulated Mucotome Electrode
10mm wide x 2mm depth (1 pc)
H143
H144
Insulated Mucotome Electrode
12mm
widex x2mm
2mmdia.
depth (1 pc)
4mm wide
H145
6mm wide x 2mm dia.
Rhinophyma Electrode Set
EE234 Set of 3
Reusable
EE233
19/64” Triangle Loop, (1 pc)
EE232
1/8” Triangle Loop, (1 pc)
EE231
1/2” Triangle Loop, (1 pc)
*Electrodes are displayed in actual size.
30
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
*Electrodes are displayed in actual size.
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
31
RF ELECTRODES
RF ELECTRODES
Reusable Electrodes* ACe-Tip™ Advanced
Composition Alloy–Low Temperture
Reusable Electrodes Sets
Rodin™ Microsurgery ACe-Tip™ Electrode Set
RACE7
TNAEE286 HLTZ Tonsilotomy Set of 3 ACe-Tips electrodes
TM
The ellman® ACe-Tip™electrodes
Includes one each of: TNAEE284, TNAEE285, TNAEE287
are designed to reduce
resistance/impedance which in
TNAEE284 HLTZ Tonsillotomy, ACe-Tip ,
TM
15mm Loop, .010 wire, 1/16” shaft (2 pcs)
Reusable
1.5” shaft length, 1/16” dia., Bendable Assortment (7 pcs)
Includes one each of:
REE305, RA2B, RA8B, RD3B, RBBB, RC3B, RB1B
turn will reduce thermal damage.
The interface between these
TNAEE285 HLTZ Tonsillotomy, ACe-Tip ,
TM
electrodes and the tissue is
biologically stable.
TNAEE287 1cm Needle, 3” Curved Sleeve ACe-Tip , 1/16” shaft (2 pcs)
TM
TNAA9B
3/8” Length
ACe-Tip Regular Wire 1/16” shaft (2 pcs)
Standard Electrode Set
S10B
Reusable
1/16” shaft size or 3/32” Use “Q” as a prefix when ordering 3/32” shaft size
Assortment (7 pcs) Includes one each of: C7B, B1B, C3B, A3B, D8B, F1B, A8B
ellman
12mm Loop, .010 wire, 1/16” shaft (2 pcs)
TM
TNAD3B
2mm Coagulating Ball
ACe-Tip 1/16” shaft (2 pcs)
TM
TNATB3B 3mm Tapered Ball
ACe-Tip 1/16” shaft (2 pcs)
TM
5mm Tapered Ball
ACe-Tip 1/16” shaft (2 pcs)
ellman
TNAD13B
TM
TNAB1B
1/4” Round Loop
ACe-Tip Fine Wire 1/16” shaft (2 pcs)
Assorted Needle Electrode Set
1/4” Round Loop
ACe-Tip Regular Wire 1/16” shaft (2 pcs)
Includes one each of: A1, A2, A9, A3, F1 (5 pcs)
TM
TNAB4B
XA
TM
TNAB2B
3/8” Round Loop
ACe-Tip Fine Wire 1/16” shaft (2 pcs)
TM
TNAB5B
3/8” Round Loop
ACe-Tip Regular Wire 1/16” shaft (2 pcs)
TM
TNAA8B
Vari-Tip™
ACe-Tip™ 1/16” shaft (2 pcs)
Assorted Round Loop Electrode Set
XB
TNAEE305 Empire microlncision™
Needle ACe-Tip™1/16” shaft (2 pcs)
*Electrodes are displayed in actual size.
● Conductivity–Advanced composition alloy RF electrode has a high conductivity which is a departure from the
traditional alloy electrode
● Lower Temperature– Advanced composition alloy RF electrode makes it possible to cut tissue at 38°C.
Separation of tissue is due to the intracellular resonance which causes the explosion of the cells at body temperature
instead of burning and charring of the cells
● Adherance Free– Non-sticking of tissue and blood to the RF advanced composition electrode
● Reduced Post-Op Pain–Reduced swelling and bruising
32
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
Fine Wire
Includes one each of: B3, B2, B9, B1, BB
XBRB
Regular Wire
Includes one each of: B6, B5, B10, B4, BB (5 pcs)
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
33
RF ELECTRODES
RF ELECTRODES
Reusable Electrodes Sets
Electrodes Accessories
Assorted Diamond Loop
Electrode Set
Fine Wire
Includes one each of: C21, C19, C17, C3, C1
XCRB Regular Wire
Includes one each of: C22, C20, C18, C6, C4
(5 pcs)
ellm
an
XCFB
Electrode Protector Stand™
H66
Electrode Protector Stand™
For regular 2” standard electrodes
Holds 12 electrodes, 6 1/16” x 6 3/32”
(1 pc)
H66A
XD
Includes one each of: D11, D10, D9, D8, D3
(5 pcs)
ellm
Assorted Ball Electrode Set
Electrode Protector Stand™
For large 4" long electrodes
Holds 12 electrodes, 6 1/16” x 6 3/32”
(1 pc)
The ellman® Electrode
Protector Stand™ protects
your electrodes from damage
and breakage during the
sterilization process.
The ellman® Electrode
Protector Stand™ will stand
on any flat surface for easy
identification and access to
each electrode.
Assorted Oval Loop Electrode Set
XPFB
Fine Wire
Includes one each of: P9, P7, P5, P3, P1
XPRB
Regular Wire
Includes one each of: P10, P8, P6, P4, P2
(5 pcs)
Electrode Block™
H1
Electrode Block™
Holds 18, 1/16" Electrodes
(1 pc)
H1A
Electrode Block™
Holds 9, 1/16" Electrodes and
9, 3/32" Electrodes
(1 pc)
QH1
Assorted Triangle Loops
Electrode Set
XTFB
Electrode Block™
Holds 18, 3/32" Electrodes
(1 pc)
Fine Wire
Includes one each of: C15, C13, C11, C9, C7
XTRB
Regular Wire
Includes one each of: C16, C14, C12, C10, C8
(5 pcs)
34
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
35
EDUCATIONAL MATERIALS
SMOKE EVACUATION SYSTEM
Educational Accessories
Device/Accessories
Compact Disks
Oculoplastic Techniques
by Jay Justin Older, MD
VCD/OP31
2 Disk Set
At ellman® we are committed
ellman® brings you the
to the ongoing education of
strongest smoke suction
the doctors as well as their
system, the Surg-e-Vac™,
patients.
with a capture of 150 feet
per minute at the inlet wand
Patented
Patient Education Brochures
tip. The unique compact
Surg-e-Vac™
SV110
SV220
Surg-e-VacTM (for 110v countries)
Surg-e-VacTM (for 220v countries)
multi-filtration technology
has been designed to trap
macro and micro airborne
Cosmetic
Eye Surgery
LIT/OP1A
Facial Veins
LIT/DE1
Radiage™
Skin
Tightening
LIT/DE2
(50 pcs)
(50 pcs)
Facial
Lesions
LIT/CO1
Treatment
of Snoring
LIT/ENT1
(50 pcs)
(50 pcs)
SurgiCart™
particles and offer a
H156
“breathe-free” environment
SurgiCartTM III with extended base, instrument
tray with gooseneck arm, adjustable height,
hospital locking wheels, rolls easily from
room to room
for you, your staff and your
patients.
(50 pcs)
Textbooks
36
Minor Surgery
H202A
Procedures for
Primary Care
A Text & Atlas
4th Edition,
by John Stuart Brown
2nd Edition
H208
by Drs. John L.
Pfenninger and
Grant C. Fowler
Eyelid
Tumors
H207
by Jay Justin
Older, MD
Oculoplastic
Surgery with
Radiofrequency
H205/BL
The Surg-e-Vac™ Smoke Evacuation System has been designed
with a high suction, high flow rate centrifugal action pump. The
ultra-quiet motor is used to draw the surgical smoke from the
surgical site through the vacuum tubing and into the Quad
Filter™ where the surgical smoke is processed by a series of
filters.
Vac Assist Stand
VV133
by Drs. G. Aimino,
G. Davi, and
M. Santella
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
37
SMOKE EVACUATION SYSTEM
MULTI-SPECIALTY ACCESSORIES
Accessories
Accessories
Surg-e-Vac™ Accessories
Iso-Dent™ Kit
Iso-Dent™ is a purified isobutyl
The accessories below are used only for Surg-e-Vac™
EID142A
cyanoacrylate formulated to
Isobutyl Cyanoacrylate Tissue Adhesive,
four 2cc Vials, 100 Squeez-etts™,
10 Super Squeez-etts™,
1 Super Dish™
Pneumatic
Footswitch
TM
Surg-e-Vac
Quadtration
Filter
SVF1 (3 pcs)
SVXF1 (12 pcs)
SVFSC
provide major advantages in
the treatment of superficial
(10-1/2 Ft. Cable)
(1 pc)
wounds.
Iso-Dent™ is a liquid monomer
For both Surg-e-Vac™ and Vapor-Vac II™ Accessories
which, upon contact with
Speculum Tubing
Reducing Package
VV130 includes
(2 pcs) VV128
(2 pcs) VV129
Plastic Hose
VV148
Reusable
7/8” diameter
(1 pc)
VV140
Speculum Tubing
Reducer Fitting
(10 pcs)
VV129
Saf-T-Wand
External Tub
VV128
VF121
1/4" Autoclavable
(2 pcs)
(3 pcs)
EID143
blood and body fluids, rapidly
Isobutyl Cyanoacrylate™ Tissue Adhesive,
four 2cc Vials, 100 Squeez-etts™,
10 Super Squeez-etts™, 1 Super Dish™
The blue color allows you to see where
you placed the Iso-Dent™
polymerizes to form a strong,
thin, flexible tissue bridge and
protective barrier to foreign
matter.
Super Dish™
(2 pcs)
Speculum Tubing
Blue Iso-Dent™ Kit
ESD230
Squeez-etts™ provide safe,
Medicament Tray and Squeez-etts™ Stand
(4 pcs)
controlled, pinpoint
application of Iso-Dent™.
Squeez-etts™
ESQ127
Vapor-Vac II™ Accessories
Liquid Dispenser
(100 pcs)
These accessories below are used only for Vapor-Vac II™
Charcoal
Filter
External
Filter
Saf-T-Wand
Filter Set
VC123
VF124
VV146
(2 pcs)
(10 pcs)
(25 pcs)
Super Squeez-etts™
Disposable
External Filter
Vapor-Vac™
Wand Clip
VV139
VV131
(25 pcs)
(1 pc)
H54
(50 pcs)
H54B
(200 pcs)
H54
38
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
H54B
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
39
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Accessories
Otorhinolaryngology
Medi-Frig™
Medi-Frig™ is a portable,
Portable Cryosurgery Skin Refrigerant
hand-held, cryosurgical
3” Length Handpiece with Locking Chuck
spray unit containing
IEC-XLP1
H11B
1 280g. can, 10 Straw Applicators
tetrafluoroethane (-54°C).
XH11B
6 cans, 60 Straw Applicators
The ellman® cryosurgical spray
is safe, storable, easily trans-
H11BCS
25 cans, 250 Straw Applicators
portable and cost-effective
compared to traditional liquid
Wipe-Its™
Reusable
For Surgitron® 4.0 Dual RF and Radiolase® II Devices
3” Length, Accepts 1/16" and 3/32" shaft, procedures for
Laparoscopy and Micro-Larynx (2 pcs)
XLP1
Reusable
For the EMC Device
3” Length, Accepts 1/16" and 3/32" shaft, for
Laparoscopy and Micro-Larynx procedures (2 pcs)
The Patented Micro-Larynx™
Probe allows quick and
nitrogen. An added advantage
efficient coagulation, automatic
is that it is nonflammable and
limiting of penetration depth
can be used in conjunction
and reduced perforation risk
with radiosurgical,
Micro-Larynx™ RF Probes
with minimized risk of injuries
electrosurgical and laser
IEC-EE275A
to larynx structures.
procedures.
Reusable
For Surgitron® 4.0 Dual RF and Radiolase® II Devices
1/16" shaft, 240mm long, (3 pcs)
The Micro-Larynx™ Probe
can be used for Granulomas,
Papillomatosis, Cyst Biopsies,
Wipe-Its™ are easy to use,
Vocal Cord Polyps, Posterior
H19
Pressure sensitive sandpaper pads
used to clean radiosurgical electrode tips
(4 pcs)
for effortless removal of tissue
Cordectomy, Glottic and
from radiosurgery tips.
Sub-glottic Angiomas,
Magnified view
Magnified view
Magnified view
Loop
Needle
Ball
EE276
EE277
EE278A
1/16" shaft, 240mm long
(1 pc)
1/16" shaft, 240mm long
(1 pc)
1/16" shaft, 240mm long
(1 pc)
Laryngeal Tumor and
Laryngeal Biopsies.
Micro Fibre® Electrode
XMF-A
Magnified view
Sterile/Single-Use
Monopolar Wire
600mm Length (1mm O.D.)
for endoscopic procedures,
Attaches to Quick-Connect™ Cable (3 pcs)
Quick-Connect™ Cable
Reusable
Proximal cable for Micro Fibre® System.
See page 8 for ordering information
40
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
41
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Otorhinolaryngology
Otorhinolaryngology
Clear-Vu™ Electrodes have
been designed to enhance
OTO-RAM™ Radiofrequency Assisted Myringotomy Set
Clear-Vu™ Bayonet Electrodes
IEC-EE600
Sterile/Single-Use, (13cm Long Shaft), (1 pc)
1/16” shaft size, 3/32” shaft size available, order with a “Q” prefix
Reusable
Two 4” tubes, 1.5mm and 2.0mm and one Myringotomy Handpiece
CV-B1 Bayonet 1mm Ball
Reusable
RF Assisted Myringotomy Handpiece (1 pc)
2mm hole
OTO-RAM™ Probes
EE601
2mm hole
50 microns alteration
Tympanic membrane
alteration zone
during the procedure.
The Clear-Vu™ electrodes
are manufactured with
CV-S Bayonet Spatula
proprietary surgical grade
material for maximum
performance and integrity.
CV-L5 Bayonet 5mm Loop
The assorted tip
CV-L7 Bayonet 7mm Loop
configurations allows for
CV-D Bayonet Diamond 11cm
precise surgical treatment.
CV-W Bayonet Fine Wire 11cm
Reusable
2.0mm Orifice
(1 pc)
Reusable
Insulated 1cm and exposed 1cm
(2 pcs)
maintaining a ‘clear view’
CV-N Bayonet microIncision™ Needle
CV-L3 Bayonet 3mm Loop
EE602
TEE230
CV-B2 Bayonet 2mm Ball
CV-B3 Bayonet 3mm Ball
Reusable
1.5mm Orifice
(1 pc)
Patented RF Myringotomy Electrode™
environment for precise
tissue interaction while
IEC-H604
The OTO-RAM™allows for an effective, safe
treatment where office or clinical procedures take
place in only a few minutes. Costs for OR
Surgery and extensive use of antibiotics
and general anesthesia are greatly
reduced. The OTO-RAM™is cost
effective compared to laser
assisted myringotomy.
access to the surgical
Bayonet RF Turbinate Volume Reduction Electrode™
OTO-Ram
Probe Tip
Reusable
Bipolar Turbinate Probe and cord (1 pc)
Tips Insulated 1cm and Exposed 1cm
IEC-I6D
The Bayonet Turbinate
For Surgitron® 4.0 Dual RF and Radiolase® II Devices
I6/JXE
For EMC Device
Electrode and Bipolar
Handpiece design includes a
OTO-Guide for RF Micro Fibre®
pencil grip for easy handling
OTO1
with a bayonet needle for easy
intranasal visualization
during surgery.
Ear Speculum for RF Micro Fibre®
ESPEC
Magnified view
42
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
43
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Otorhinolaryngology
Otorhinolaryngology
RAUP Electrode™
H81A1
Sterile/Single-Use
RAUP Radiosurgically Assisted
Uvulopalatoplasty
(2 pcs)
Patented RF Suction Adenoid Probes
IEC-H85
Reusable
Set of 3 Probes, Quick-Connect™ Cable, and Cleaning Brush
IEC-H86 Small Probe
9mm with Quick-Connect™ Cable, (1 pc)
Sub-Mucosal VTR (UPP) Electrode
TEE229A
Sterile/Single-Use
For volumetric reduction
of redundant tissue
(2 pcs)
IEC-H87 Medium Probe
15mm with Quick-Connect™ Cable, (1 pc)
IEC-H88 Large Probe
19mm with Quick-Connect™ Cable, (1 pc)
Tongue Base Reduction Electrode™
TEE605
Sterile/Single-Use,
For volumetric reduction
of redundant tissue
(2 pcs)
Cleaning Brush for Suction Probe
H89
(3 pcs)
Patented Suction Tonsillectomy Probe™
and Quick-Connect™ Cable
IEC-H83/SP
Adenoid RF Electrode™
TEE228
Reusable
For Surgitron® 4.0 Dual RF and Radiolase® II Devices
H83/SP
For EMC Device
Reusable
1/4” Triangle, 4” Length, Teflon Insulated
(2 pcs)
HLTZ Tonsillotomy Electrode™
TEE284
Reusable
.010 Wire, 15mm Loop
(2 pcs)
Patented RF Bipolar
Tonsil Reduction Probe™ and Quick-Connect™ Cable
IEC-H84
Reusable
For Surgitron® 4.0 Dual RF and Radiolase® II Devices
H84
For EMC Device
44
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
45
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Otorhinolaryngology
Otorhinolaryngology
Patented RF Suction Coagulator™
RF Assisted Tonsillotomy (RAT) Ball Electrodes™
HD41
EE264 Set of 3
Reusable
TEE261 2.0mm Ball 4" long (2 pcs)
Sterile/Single-Use
For use with Quick-Connect™ Cable, (12 pcs)
(see page 8 for Quick-Connect™ Cable)
Magnified view
Magnified view
Patented RF Angled Suction Coagulator™
TEE262 2.36mm Ball 4" long (2 pcs)
HD42
Sterile/Single-Use
For use with Quick-Connect™ Cable, (12 pcs)
(see page 8 for Quick-Connect™Cable)
The Ball Tonsil Probe is an
important advancement over
Magnified view
the traditional tonsillotomy.
TEE263 3.17mm Ball 4" long (2 pcs)
Magnified view
The RAT procedure permits
controlled reduction up to 80%
Magnified view
of the tonsil without excessive
Patented Suction Coagulation Kit
Cryptolysis Electrode
Reusable
TE1022B
IEC-H40
Reusable
(2 pcs)
Shipped with three 3” and three 6” tubes
For Surgitron® 4.0 Dual RF and Radiolase® II
Devices
H40
Shipped with three 3” and three 6” tubes
For EMC Device also includes 1/16”, 3/32”
and 1/8” Caliber sizes
Stylus Round Wire
thermal damage or blood loss.
An RF cryptolysis probe comprises a generally elongated insulated structure leading
to a distal end that is angled downward and terminates in a narrow tip that is
exposed. The exposed tip is inserted into tonsillar crypts that may contain bacteria,
and activated to clean out any debris, then to sterilize the canal and seal the
surface without thermal damage to surrounding tissue.
Polyp Snare™ System for Nasal Polyps
Cryptolysis
IEC-H301
Reusable
H44 Suction Tube 6” Long, 1/16” Orifice
For Surgitron® 4.0 Dual RF and Radiolase® II Devices
with Snare Cable and 3 wires
H45 Suction Tube 6" Long, 3/32" Orifice
H301
For EMC Device
with Snare Cable and 3 wires
H46 Suction Tube 6" Long, 1/8" Orifice
H47 Suction Tube 3-3/4" Long, 1/16" Orifice
H48 Suction Tube 3-3/4" Long, 3/32" Orifice
H49
46
Suction Tube 3-3/4" Long, 1/8" Orifice
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
H7A
Snare Wires
6 wires
H7B
Snare Cable
For EMC Device (1 pc)
IEC-H7B Snare Cable
For Surgitron® 4.0 Dual RF and Radiolase® II
Devices (1 pc)
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
47
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
General Surgery/Proctology
Gynecology
Patented RF Laparoscopic Handpiece
Radiosurgery
Touch Technique
IEC-XLP1
Reusable
LLETZ Electrodes Assortment Set
The ellman® LLETZ loop
W4
W4D
electrodes are used for the
One of each in 5 styles, reusable (5 pcs)
One of each in 5 styles, Sterile/Single-Use (5 pcs)
diagnosis and treatment of
Laparoscopy Handpiece, 3” Length accepts
1/16” and 3/32” shafts
For Surgitron® 4.0 Dual RF and Radiolase® II Devices
(1 pc)
LLETZ Individual Electrodes
Available in 1/16” or 3/32”
Use “Q” as a prefix when ordering 3/32” shaft size
Use “D” as a suffix when ordering Sterile/Single-Use Versions of the LLETZ loop electrodes.
cervical intraepithelial
neoplasia (CIN) and
dysplasia.
Patented RF Laparoscopic Electrodes™
Endometriosis
L7
Reusable
Lap-Trode Assortment, 37.5mm Length Electrodes (5 pcs)
Reusable
Lap-Trode Individual Electrodes, 37.5mm Length Electrodes, 1/16” Shaft
W1
W1D
15mm x 10mm Loop, reusable (1 pc)
15mm x 10mm Loop, Sterile/Single-Use (5 pcs)
W2
W2D
20mm x 10mm Loop, reusable (1 pc)
20mm x 10mm Loop, Sterile/Single-Use (5 pcs)
W3
W3D
25mm x 10mm Loop, reusable (1 pc)
25mm x 10mm Loop, Sterile/Single-Use (5 pcs)
F2
F2D
Endo-Cervical Box 8mm x 11mm Box, reusable (1 pc)
Endo-Cervical Box 8mm x 11mm Box, Sterile/Single-Use
(5 pcs)
W18
W18D
5mm Ball, reusable (1 pc)
5mm Ball, Sterile/Single-Use (5 pcs)
L3 2mm Ball Lap-Trode
Myomectomy
Magnified view
L4 9.5mm Needle Lap-Trode
Magnified view
L5 2.3mm Hook Lap-Trode
Luna
Conization Electrode™
Reusable
G1
G1/4
Magnified view
L6 2.3mm Blade Lap-Trode
Conization Electrode
4" long, Rotated at 360° to provide a cone shaped specimen
Standard Electrode Set
S10B/4 4” shaft length, (7pcs) see page 28 for more information
Magnified view
L8 Hook Needle Lap-Trode
External Genital Lesion RF Electrodes™
Reusable
W15
Complete Set of Genital Lesion Electrode
set of 4, includes W16, W17, W18 and W19 Electrodes
Gupta RF Gun
(Pravin Gupta Procto-Gun)
W16
90mm Length, Angled Box
IEC-FSGUN
W17
4mm Length, Box
W18
90mm Length, 5mm Ball
W19
90mm Length, 3/8" Needle
Magnified view
Reusable
Accepts 1/16" and 3/32” Shaft Electrodes (1 pc)
For Surgitron® 4.0 Dual
48
RF Fingerswitch
Gun Handle
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
49
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Gynecology
Plastic Surgery
LLETZ Bayonet Electrodes
W35 LLETZ Bayonet Electrode Set (5 pcs)
Reusable. Use “D” as a suffix when ordering Sterile/Single-Use
W35D Sterile/Single-Use (5 pcs)
Javate/Khan RF Endoscopic Forehead Suction Probe™
Reusable
W32 Reusable
Bayonet, 25mm Loop (1 pc)
W32D Sterile/Single-Use (5 pcs)
W31 Reusable
Bayonet, 20mm Loop (1 pc)
W31D Sterile/Single-Use (5 pcs)
W30 Reusable
W30D
W34
W34D
W33
W33D
The Javate/Khan Endoscopic
Bayonet, 15mm Loop (1 pc)
Sterile/Single-Use (5 pcs)
Reusable
Bayonette, 5mm Ball (1 pc)
Sterile/Single-Use (5 pcs)
Reusable
Endo-Cervical Bayonet,
8mm Box (1 pc)
Sterile/Single-Use (5 pcs)
Javate/Khan Endo Forehead Suction Set
IEC-EE260
Reusable
Includes 2 probes, one Spade, one Scalpel with Suction
Handpiece and Cable for Surgitron® 4.0 Dual RF and
Radiolase® II Devices
EE260
For EMC Device
Forehead Suction Probe™
utilizes a unique combination
of suction and radiofrequency
cutting. It Improves operating
efficiency and significantly
enhances results while
Vaginal Speculums
H55 Vaginal Speculum - Large, 5” Length
H57 Vaginal Speculum - Standard, 4 1/2” Length
H58 Vaginal Speculum (2 pcs - Large and Standard)
Javate/Khan Coated Flat Scalpel
EE257
Reusable
7/16” Tip Diameter (1 pc)
providing ample access and
visualization to the surgical
site. The Javate/Khan
Endoscopic Forehead Suction
Stylus
Probe™ enables precise and
controlled muscle resection
Vaginal Lateral Wall Retractor
H69
Magnified view
with profound hemostasis,
eliminates coronal scar and
Monsel’s Solution
Javate/Khan Coated Spade
H90
EE258
Reusable
500 ml (Ferric Subsulfate) Post-Operative Medicament
eliminates potential hair loss.
7/16” Tip Diameter (1 pc)
Needle Extender/Measured Dose Syringe
H71
Magnified view
50
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
51
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Plastic Surgery
Dermatology
Patented Dr. Constantin Stan Monopolar Forceps
The ellman® Micro, Mini and
Mono Stan Forceps
simultaneously dissect and
Micro Stan RF Forceps™
IEC-MJ21
coagulate with little
For treating telangiectasia and epilation of hair follicles
H135A
For EMC Device
IEC-H135A For Surgitron® 4.0 Dual RF and Radiolase® II Devices
Package Includes:
Reuseable. One MicroInsulated Needle Handpiece
One package of 50 MicroInsulated Sterile Needles and
One package of 50 Patient Education Brochures
Reusable
Suggested for Blepharoplasty and Facelift procedures
3.5” Length
Includes Quick-Connect™ Cable and Video CD
For use with Surgitron® 4.0 Dual RF Device
bleeding. Using the 4.0
the Stan Forceps results in
Reuseable
MJ21
dramatically shorter
IEC-XH136
For EMC Device
recovery time as well as
MHz radiofrequency with
reducing the risk of
complications such as
The ellman® Cosmetic
Cosmetic Treatment Package
XH136
Reuseable
H137
H1375
LIT/DE1
you to add more revenue to
your practice this year by using
ellman® radiofrequency!!
This is an effective comfortable
MicroInsulated Needle HandpieceTM
For EMC Device (2 pcs)
MicroInsulated Needle Handpiece
For Surgitron® 4.0 Dual Devices
(2 pcs)
Treatment Package will allow
way to remove small unsightly
TM
“spider veins” with minimal
recovery time, minimal or no
MicroInsulated Sterile Needles (50 pcs)
MicroInsulated Sterile Needles – bulk pkg (250 pcs)
Patient Education Brochure: FAQ’s – Facial Veins (50 pcs)
scarring and immediate
improvement in appearance.
infection, bleeding and
Magnified view
post-operative pain.
Mini Mono Stan RF Forceps™
Dermatology Electrode Assortment Set
Until recently, there were
IEC-MJ11/M
DDERM40
only surgical means for
Reusable
Monopolar Forceps with Cutting, Coagulation, Irrigation, Suction Port
Suggested for Face Lifts
4.875” Length
Includes Quick-Connect™ Cable and Video CD
For use with Surgitron® 4.0 Dual RF Device
Assorted, Sterile/Single-Use Electrodes, 1/16” shaft (4 electrode styles)
eliminating larger veins.
D8D (15 pcs)
With the advent of ellman®
B1D (5 pcs)
radiowave sclerotherapy,
most veins can now be
MJ11/M
F1D (15 pcs)
For EMC Device
completely and permanently
A8D (5 pcs)
eliminated without surgery
or injections.
Magnified view
Mono Stan RF Forceps™
IEC-MJ11
Reusable
Monopolar Forceps with Cutting, Coagulation, Irrigation, Suction Port
Suggested for Breast Augmentation Procedures
6.125” Length
Includes Quick-Connect™ Cable and Video CD
For use with Surgitron® 4.0 Dual RF Device
Mono and Mono Stan Forceps
are serrated to provide better
hemostasis.
Insulated Sclerotherapy Needles™
D41
D42
D43
27 Gauge, 1" Needle
30 Gauge, 1/2" Needle
Insulated Sclerotherapy Needle Set, 27-Gauge and 30-Gauge
(2 pcs, one of each)
For EMC Device
Rhinophyma Electrode Set see page 30
Corneal Shields™ see page 57
Chedly Eyelid Retractor see page 57
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
MJ11
52
The insides of tips on the Mini
53
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Radiage /Cosmetic Rejuvenation
Radiage /Cosmetic Rejuvenation
TM
Radiage™ Wands
U.S. FDA Approval Pending and only
available to our International Doctors
TM
Radiage™
Radiage™ Wands
Radiage™ is a RF non-
Tighter skin without surgery
U.S. FDA Approval Pending and only
available to our International Doctors
ablative procedure for skin
rejuvenation. It is not a laser.
Unlike prior generations,
today’s adults are proactive
about their health and
appearance. They want to
RHP05
look as young as they feel.
Radiage™ Wand, “Valerii” 5mm,
Single-Use, Disposable
With increasing numbers,
our younger, more active
Radiage™ Wand Introductory Kit
RHPK/Intro
Includes: 3 pcs each of RHP05; RHP10, and RHP15 Wands; 8 pcs RCGI RF Cool Gel™; one package
H781 Eye Shields, and one package LIT/DE2 Radiage Patient Education Brochures (50 pcs)
It is a patented radio
frequency system.
Radiage™ Wand Kit, “Valerii” 5mm
RHPK05
Includes: 10 pcs RHP05 Wands; 10 pcs RCG1 RF Cool Gel™; one package H781 Eye Shields,
and one package LIT/DE2 Radiage™ Patient Education Brochures (50 pcs)
patients are having the
early signs of aging such as
“crows feet” and frown
lines. They are requesting
RHP10
non-invasive, non-surgical
Radiage™ Wand, 10mm,
Single-Use, Disposable
procedures that have little,
if any, down time.
Radiage™ Wand Kit, 10mm
RHPK10
Includes: 10 pcs RHP10 Wands; 10 pcs RCG1 RF Cool Gel™; one package H781 Eye Shields,
and one package LIT/DE2 Radiage™ Patient Education Brochures (50 pcs)
RHP15
Radiage™ Wand, 15mm,
Single-Use, Disposable
Radiage™ Wand Kit, 15mm
RHPK15
Includes: 10 pcs RHP15 Wands; 10 pcs RCG1 RF Cool Gel™; one package H781 Eye Shields,
and one package LIT/DE2 Radiage™ Patient Education Brochures (50 pcs)
(See page 36 for Radiage Patient Education Brochure, Cat. No. LIT/DE2
(See page 57 for Corneal Shields, Cat. No. H781
RF Cool Gel™
The advanced RF Cool-Gel™
incorporates a cryo-gel
to cool the skin’s outer
surface while the
RF energy slightly heats
and modifies the soft
tissues beneath the skin.
54
DHPG8 RF Cool Gel™,
8 bottles, 18ml. each
DHPG15 RF Cool Gel™,
15 oz. bottle with pump top.
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
55
MULTI-SPECIALTY ACCESSORIES
MULTI-SPECIALTY ACCESSORIES
Ophthalmology/Oculoplastics
Ophthalmology/Oculoplastics
Patented RF Wedge Resection Electrode Set™
Surgical RF handpiece which
Javate-Pamintuan Dacryoplasty (JPD) Electrode
EE255
is ergonomically designed in a
TEE606
Reusable
(set of three)
gun shape to reduce the
Reusable
(2 pcs)
Patented RF Wedge Resection Electrode
pressure on the hand and
fingers and is easier on the
TEE237
1/4" tip (2 pcs)
wrists during surgical
Corneal Shields™
H781
TEE236
TEE235
procedures.
3/16" tip (2 pcs)
The ellman® Corneal Shield™
Autoclavable
Assorted Package
one pair each size,
small, medium, large and
1 suction handle
1/8" tip (2 pcs)
tautens the skin to allow for
more precise incisions. It is
an excellent aid when
performing periorbital surgery
Beigi Minimally Invasive Entropion Electrode
H75A
H76A
H77A
TEE603
Sterile/Single-Use
(2 pcs)
Small - Red (2 pcs, 1 handle)
Medium - Green (2 pcs, 1 handle)
Large - Blue (2 pcs, 1 handle)
and aids in the protection
from cautery, desiccation,
irritation or trauma, during
The Beigi Entropion Electrode
is designed to reach deep
Ophthalmic Micro-Dissection Electrodes™
Suction Handle (2 pcs)
Suction Handle (25 pcs)
and after surgery of eyelid
and orbital regions.
tissue below orbicularis oculi
TA10/C1
muscle at the lower border of
Reusable. 2” Electrodes
1.5mm of active .004 Wire (2 pcs)
the tarsus.
TA10/C2
H78A
H78B
Chedly Eyelid Retractor
The Chedly Eyelid Retractor
H21A
is designed to allow easy
Reusable
access for oculoplastic
(1 pc)
Reusable. 2” Electrodes
3.0mm of active .004 Wire (2 pcs)
procedures i.e. upper and
TA10/C3
lower blepharoplasty, ptosis,
Reusable. 2” Electrodes
5.0mm of active .004 Wire (2 pcs)
trichiasis and minor
Baker Brow Probe
EE279
A10
Reusable
Set of two (1.5mm and 3.0mm, .004 Wire - one of each)
eyelid procedures.
Reusable
(2 pcs)
Note: Add/OP after the Catalog Number to order 1/2” shorter,
Ophthalmic Micro-Dissection Electrodes™
Magnified view
56
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
57
MULTI-SPECIALTY ACCESSORIES
Family Practice/Podiatry
ellman® Digit Tourniquets
H97 ellman® Cots – Small (12 pcs)
H98 ellman® Cots – Medium (12 pcs)
H99 ellman® Cots – Large (12 pcs)
Ingrown Toenail
ECOTS- 4 each small, medium and large
ellman ®
Cots.
Insulated Matrixectomy Electrodes™*
The ellman® radiosurgical
H9
nail matrixectomy technique
Reusable
Set of 3 electrodes
1/16” or 3/32” shaft
Matrixectomy Electrode Set
Includes one each of: H10D, H10E, H10A
for Ingrown Toenail allows the
matrix to be destroyed
electrically with a teflon
H1OD 2mm Matrix Electrodes
Reusable (2 pc)
H1OE
4mm Matrix Spicule Electrodes
Reusable (2 pc)
H1OA
Matrix Spicule (Ball) Electrode
Reusable (1 pc)
coated electrode, which
protects the overlying
eponychium. The main
advantage of the radiosurgical
matrixectomy is that it
reduces weeping and
Standard Podiatry Electrode Set*
S11B
Reusable
1/16” or 3/32” shaft
Includes one each of: D8, A3, B4, B5,
F1, A8
(6 pcs)
*Electrodes are displayed in actual size.
58
For orders call e l l m a n at: (800) 835-5355 • (516) 594-3333 • fax (516) 569-0054
For more information, visit our website: www.ellman.com
postoperative pain and
promotes faster healing.
Established in 1955
C
N
ISO
O
®
Y
C
RTIFI
ED
E
The “e” in ellman® stands for Excellence in Quality and Customer Satisfaction.
M PA
ellman International, Inc.
3333 Royal Avenue, Oceanside, N.Y. 11572-3625 U.S.A.
(800) 835-5355 • (516) 594-3333 • Fax: (516) 569-0054
www.ellman.com
M7098
Copyright 2008 ellman International, Inc. All Rights Reserved.
0413