Specification sheet LX885
LORO-roof drainage systems
Specification sheet LX 885
Specification sheet LX 885
Roof drainage systems
made of aluminium,
Series O
Main drainage
Gravity flow
Silent Power
Discharge rate: 4,6 l/sec
Water height: 35 mm
Roof penetration: Diameter:
DN 100
LX-Number:
LX 885 Weir height:
0 mm
Drain:ventilated
Downpipe:
not ventilated
Downpipe height:
Drainage:
in sewer
-
LX 885 Piece list
1 x Art-Nr. 05510.100X, LORO-X Stand pipe
4 x Art.-Nr. 00911.100X, LORO-X Sealing element
1 x Art.-Nr. 00986.000X, LORO-X Lubricant
1 x Art.-No. choose drain on page two!
1 x Art.-Nr. 01201.100X, LORO-X Pipe with one socket
1 x Art.-Nr. 00300.100X, LORO-X Bend
1 x Art.-Nr. 01001.100X, LORO-X Pipe with one socket
CAD
Water height h [mm]
hQ - Head Discharge curve
Discharge Q [l/sec]
Systemshape
Systempower
Water height
mm
Discharge
l/sec
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
1,0
1,6
2,3
3,2
3,9
4,6
5,4
6,4
7,4
8,1
8,6
9
9,4
9,9
Silent Power
DATENBLATT LX885 ENG
1
LORO-roof drainage systems
Specification sheet LX 885
Choose drain for piece list on page one!
DN 100
without thermal insulation
500
ø330
ø260
ø220
3°
165
ø147
ø102
116
36 2
105
90
min. 40
max. 180
105
90
500
ø330
ø260
ø220
ø147
240
ø102
116
Series O
two-piece
connection sleeve
3°
Series O
one-piece
connection sleeve
36 2
LX885-6X
Drain Art.-No. 17132.100A
165
LX885-5X
Drain Art.-No. 17131.100A
240
with thermal insulation
Drain Art.-No. 17145.100A
Drain Art.-No. 17146.100A
Series O
one-piece
connection sleeve
Series O
two-piece
connection sleeve
500
ø330
ø260
ø220
105
90
ø147
200
165
36
2
min. 40
max. 180
3°
ø147
ø102
116
2
200
165
36
105
90
500
ø330
ø260
ø220
ø102
116
LX885-8X
3°
LX885-7X
240
325
256
240
325
256
with thermal insulation and heating
Series O
two-piece
connection sleeve
500
ø330
ø260
ø220
105
90
240
325
256
200
165
min. 40
max. 180
3°
ø147
ø102
116
2
200
165 36
105
90
500
ø330
ø260
ø220
ø147
ø102
116
Series O
one-piece
connection sleeve
3°
LX885-10X
Drain Art.-No. 17148.100A
36 2
LX885-9X
Drain Art.-No. 17147.100A
240
325
256
Heat tracing: Lorowerk recommends to check all drains and pipes with regard to their frost-sensibility. Where necessary, these