Great Lakes

Transcription

Great Lakes
Great Lakes
Bracket Catalog
2016
Exceptional Quality.
200 Cooper Avenue
PO Box 5111
Tonawanda, NY 14151-5111
1.800.828.7626 (U.S. & Canada)
716.871.1161 (Worldwide)
Email: [email protected]
www.GreatLakesBrackets.com
SMPP580Rev031716
Manufactured by Aditek® Orthodontics
Outstanding Value.
After years of research and evaluation, Great Lakes is proud to offer a full line of quality fixed
appliances that are value priced for practice profitability. We endorsed these brackets specifically
for their outstanding value and exceptional quality. The intelligent design, versatility, and maximum
reliability of this bracket line meets our stringent standards of excellence to bear our name.
Great Lakes is thrilled to now offer orthodontic brackets to our customers worldwide. Please take
time to watch our information videos to learn more about the various systems. Our team of bracket
specialists are available to answer your questions, and provide free, personalized consultation.
James R. Kunkemoeller
President and CEO
Great Lakes Orthodontics, Ltd.
EMPLOYEE OWNED
1
General Information
WELCOME
Since 1967, Great Lakes has been dedicated to helping customers achieve business success by providing outstanding customer service, technical
support, and products guaranteed to be of the highest quality and workmanship. Please let us know how we can partner with you!
ORDERING OPTIONS
PAYMENT OPTIONS & TERMS
When ordering by phone, fax, or email, please be as specific as
possible. Include the item number, quantity desired, and descriptive
information such as size and color, as appropriate. Orders are
processed Monday-Friday during normal business hours. In most
cases, routine orders received by 12 p.m.(Eastern Standard Time)
are shipped within 24 hours.
Payment Options:
Credit Cards: We accept MasterCard, Visa, and American Express.
Other: Checks, money orders, wire transfers, and eChecks.
Payment Terms:
Invoices are payable within 30 days of invoice date (some exceptions
apply). A $35 fee will be charged for each returned check. (Prices
are subject to change.)
Phone:1.800.828.7626(U.S. & Canada)
716.871.1161 (Worldwide)
• Our phone lines are open Monday-Friday from 8 a.m. to 5 p.m. (Eastern Standard Time).
SHIPMENTS
• All shipments are F.O.B. Buffalo unless otherwise stated.
• Great Lakes will determine the type of carrier for all shipments except when the customer has provided special instructions. We
will not accept liability for shipping charges, duty or tax.
• An itemized packing list will accompany each order. To ensure proper shipment, compare packing list with items received. If incorrect, Great Lakes must be notified within 10 days of receipt of
m
erchandise.
• If merchandise is damaged during shipping, notification must be
made to the carrier within seven days. Retain original damaged packing for carrier evaluation. Great Lakes must then be contacted so that arrangements can be made for a replacement
o
rder.
• Backorders: Backorders that weigh less than 1 lb or are valued
under $20.00 will ship at no charge. Customers are responsible for
freight charges on backorders that are outside these parameters.
Web: www.GreatLakesBrackets.com
• For your convenience, Great Lakes products, can be ordered
online 24/7.
Email: [email protected]
• Please feel free to email us with your order, questions, or concerns.
• If paying by credit card, indicate your card number, expiration date,
CVV2 security code, and name on the card.
FAX: 716.253.6383
• List your phone number and email on your fax order.
• If paying by credit card, indicate your card number, expiration date,
CVV2 security code, and name on the card.
Mail Orders:
• Address orders to: Bracket Customer Service
Great Lakes Orthodontics, Ltd.
200 Cooper Avenue
Tonawanda, NY 14150
• Be sure to include the street address, as carriers will not deliver to
a P.O. Box.
• List your phone number and email on your order.
• If paying by credit card, indicate your card number, expiration date,
CVV2 security code, and name on the card.
RETURN & CREDIT POLICY
To help us quickly process your return:
• All returns require a Customer Return Service (CRS) Authorization
N
umber.
• Returned items must be unused and in resalable condition.
• Returns must be made within 30 days, upon receipt by customer, to
avoid restocking charges. Great Lakes reserves the right to refuse
credit on any item returned after 30 days.
• Returns after 30 days are subject to a 15% restocking charge unless the item is damaged in shipping or shipped in error.
• All products must be returned prepaid and insured at full invoice
v
alue.
MINIMUM ORDER
A $30 minimum order is requested. Whenever possible, group your
orders to meet the minimum and to help keep your shipping costs
lower.
DISCOUNTS
PROGRAMS
Customers who qualify for special discounts, such as students or
Advantage Program Members, will automatically receive their standard
discount or the sale price, whichever is the best savings.
Discount Program for 1st Year Graduates: For a period of one
year after graduation, dental school graduates are eligible for a
15% discount on most products, and a 10% discount on most
appliance fabrication service from our laboratory (some exclusions
apply). Participants can also receive advice on selecting the right
products for their practice as well as technical assistance.
2
General Information
TABLE OF CONTENTS
BRACKET SYSTEMS
4-23
Self Ligating
EasyClip+® ..................................................................................... 4-15
BioTru™ Classic ................................................................................ 16-17
Aesthetic
BioTru™ Ceramic ......................................................................... 18-19
BioTru™ Sapphire ........................................................................20-21
BioMax® ............................................................................................22-23
ARCHWIRES
24-29
BioTru™ Reverse Curve of Spee..................................................... 25- 26
BioTru™ NiTi..............................................................................24,26-27
BioTru™ Copper ............................................................................... 24, 27
BioTru™ Contour .............................................................................. 24, 27
BioTru™ Retraction.......................................................................... 25, 28
BioTru™ Beta Titanium .................................................................... 24, 29
BioTru™ Stainless............................................................................ 25, 29
AUXILIARIES
30-32
Buccal Tubes.................................................................................... 30-31
Hooks & Stops ....................................................................................... 32
NiTi Springs............................................................................................ 32
ACCESSORIES
33-35
Ligatures ................................................................................................ 33
Adhesives......................................................................................... 34-35
Bite Ramps............................................................................................. 35
To our valued customers: Great Lakes has made every reasonable
effort to ensure the accuracy of this catalog, including product
descriptions and depiction. However, errors do occur. Great Lakes
reserves the right to correct any errors, inaccuracies, or omissions as
appropriate. Brackets are not for sale in Canada.
Prices are subject to change without notice.
ISO 13485: 2003
Registered
3
Extreme Versatility. Exceptional Control.
The EasyClip+® Systems can be used as fully passive, fully
interactive, or a combination of both. This hybrid approach
enables you to use both passive and interactive brackets,
offering a variety of treatment options.
^ĞůĨͲ>ŝŐĂƟŶŐƌĂĐŬĞƚ^LJƐƚĞŵƐ
Intelligently designed, EasyClip+ is engineered for comfort,
easy placement, and secure bonding.
ONE SYSTEM
Multiple Applications • Improved Clinical Management • Faster Results
Defined and spacious
tie-wing undercuts
if ligation is needed
}
Rounded corners provide
maximum patient comfort
Mesial to Distal slot
clip coverage offers
total rotational control
An ultra low profile
provides maximum
patient comfort.
Passive (Flat Tab)
Open mini twin
design allows
optimal patient
hygiene
Planar thermal NiTi
clip will not deform
or age for the
life of treatment
V channel for easy
positioning reference
Dual lock clip stays
shut - locks
securely
Interactive
(Curved Tab)
Mushroom-shaped
pylons create undercuts
for superior bond strength
Compound contour
base for easy,
accurate placement
KEY ADVANTAGES
• Innovative chairside system reduces time and costs
associated with changing archwires and appliances
Easy to open/close–no
special instruments
required. Lever action
opening of the clip offsets
forces for patient comfort.
To Close: Use a utility
plier, tweezer, or fingertip.
Audible ‘Click’ when
closing the clip. Opens
easily using an explorer.
• Longer time intervals between visits
• Well-defined Archwire Sequencing Protocols
• A complete archwire system with ‘Force Modules’
specifically calibrated for Self-Ligating Brackets
• Physiologically and mechanically advantageous
‘Light Forces’
AVAILABLE PRESCRIPTIONS
• Damon® Low Torque
• Damon® Standard Torque
• Damon® High Torque
• ROTH
• MBT
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
4
Brackets-Self-Ligating
PASSIVE
DAMON STANDARD PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.21.0090
Hooks on 3. 4 & 5
20 brackets
74.02.910SP - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
7°
5°
4°
0.25 mm
2.7 mm
6°
9°
0°
0.65 mm
2.9 mm
15°
5°
0°
0.50 mm
2.9 mm
15°
5°
0°
0.50 mm
2.7 mm
6°
9°
0°
0.65 mm
3 mm
7°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
-11°
2°
2°
0.25 mm
05.21.1214
05.21.1214
05.21.1213 05.21.1212
05.21.1211 05.21.1221
05.21.1222
05.21.1223
05.21.1224
05.21.1224
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
7°
-3°
-3°
-3°
-3°
7°
-12°
-17°
4°
4°
5°
4°
2°
2°
4°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
05.21.1245
5
05.21.1244
5
05.21.1243
5
05.21.1242
5
05.21.1241
5
05.21.1231
5
05.21.1232
5
05.21.1233
5
05.21.1234
5
05.21.1235
5
2.7 mm
-5°
9°
0°
0.65 mm
2.9 mm
2°
5°
0°
0.50 mm
2.9 mm
2°
5°
0°
0.50 mm
2.7 mm
-5°
9°
0°
0.65 mm
3 mm
-9°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
-11°
2°
2°
0.25 mm
DAMON LOW TORQUE PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.21.1090
Hooks on 3. 4 & 5
20 brackets
74.02.910LP - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
-9°
5°
4°
0.25 mm
74.02.814PS 74.02.814PS 05.21.1013 05.21.1012
05.21.1011 05.21.1021
05.21.1022
05.21.1023 74.02.824PS 74.02.824PS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
0°
-11°
-11°
-11°
-11°
0°
-12°
-17°
4°
4°
5°
4°
2°
2°
4°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.02.845PS
5
74.02.844PS
5
05.21.1043
5
05.21.1042
5
05.21.1041
5
05.21.1031
5
05.21.1032
5
05.21.1033
5
74.02.834PS
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
5
74.02.835PS
5
Brackets-Self-Ligating
PASSIVE
DAMON HIGH TORQUE PRESCRIPTION
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
74.02.910AP/BP/CP - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
11°
5°
4°
0.25 mm
2.7 mm
13°
9°
0°
0.65 mm
2.9 mm
22°
5°
0°
0.50 mm
2.9 mm
22°
5°
- 0°
0.50 mm
2.7 mm
13°
9°
0°
0.65 mm
3 mm
11°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
74.02.814PS 74.02.814PS 05.21.1113 05.21.1112
05.21.1111 05.21.1121
05.21.1122
05.21.1123 74.02.824PS 74.02.824PS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-5°
13°
0°
0°
0°
0°
13°
-5°
-17°
4°
4°
5°
0°
0°
0°
0°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0. 15 mm
74.02.845PS
5
05.21.1144
5
05.21.1143
5
74.02.841PH
5
74.02.841PH
5
74.02.841PH
5
74.02.841PH
5
05.21.1133
5
05.21.1134
5
74.02.835PS
5
2.7 mm
8°
9°
0°
0.65 mm
2.9 mm
12°
5°
0°
0.50 mm
2.9 mm
12°
5°
- 0°
0.50 mm
2.7 mm
8°
9°
0°
0.65 mm
3 mm
0°
11°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
ROTH PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.21.0390
Hooks on 3. 4 & 5
20 brackets
74.32.910P - Hooks on 3 .022
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
0°
11°
4°
0.25 mm
05.21.0314
05.21.0314
05.21.0313 05.21.0312
05.21.0311 05.21.0321
05.21.0322
05.21.0323
05.21.0324
05.21.0324
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-22°
-17°
-11°
0°
0°
0°
0°
-11°
-17°
-22°
0°
0°
5°
0°
0°
0°
0°
5°
0°
0°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
05.21.0345
5
05.21.0344
5
05.21.0343
5
05.21.0341
5
05.21.0341
5
05.21.0341
5
05.21.0341
5
05.21.0333
5
05.21.0334
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
6
05.21.0335
5
Brackets-^ĞůĨͲ>ŝŐĂƟŶŐ
PASSIVE
MBT PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.21.0890
Hooks on 3. 4 & 5
20 brackets
74.82.910P - Hooks on 3 .022
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
8°
4°
0.25 mm
2.7 mm
10°
8°
0°
0.65 mm
2.9 mm
17°
4°
0°
0.50 mm
2.9 mm
17°
4°
- 0°
0.50 mm
2.7 mm
10°
8°
0°
0.65 mm
3 mm
-7°
8°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
05.21.0814
5
5
15
05.21.0814
5
4
14
05.21.0813
5
3
13
05.21.0812
5
2
12
05.21.0811
5
1
11
05.21.0821
5
1
21
05.21.0822
5
2
22
05.21.0823
5
3
23
05.21.0824
5
4
24
05.21.0824
5
5
25
45
5
3 mm
-17°
2°
4°
0.15 mm
44
4
3 mm
-12°
2°
4°
0.15 mm
43
3
2.9 mm
-6°
3°
2°
0.20 mm
42
2
2.7 mm
-6°
0°
0°
0.45 mm
41
1
2.7 mm
-6°
0°
0°
0.45 mm
31
1
2.7 mm
-6°
0°
0°
0.45 mm
32
2
2.7 mm
-6°
0°
0°
0.45 mm
33
3
2.9 mm
-6°
3°
2°
0.20 mm
34
4
3 mm
-12°
2°
4°
0.15 mm
35
5
3 mm
-17°
2°
4°
0.15 mm
05.21.0845
5
05.21.0844
5
05.21.0843
5
05.21.0841
5
74.82.841P
5
74.82.841P
5
74.82.841P
5
05.21.0833
5
05.21.0834
5
05.21.0835
5
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
SYSTEM CONFIGURATIONS
TOTALLY PASSIVE - .022"
TOTALLY INTERACTIVE - .022"
Less ligation friction and lower
force mechanics throughout
treatment. No wires are actively
engaged by the clip.
Less ligation friction during initial
leveling and aligning. Increased
torque and rotation control during
finishing.
Hybrid & Dual Slot Systems
HYBRID SYSTEM Interactive .022" / Passive .022"
HYBRID DUAL SLOT SYSTEM Interactive .018" / Passive .022"
INTERACTIVE DUAL SLOT SYSTEM Interactive .018" / Interactive .022"
Features the same slot size and
both passive and interactive
self-ligating brackets.
Features different slot sizes and
both passive and interactive selfligating brackets.
Features different slot sizes and only
interactive self-ligating brackets.
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
7
Brackets-Self-Ligating
INTERACTIVE
DAMON STANDARD PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
74.02.900SI
Hooks on 3. 4 & 5
20 brackets
74.02.910SI - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
7°
5°
4°
0.25 mm
2.7 mm
6°
9°
0°
0.65 mm
2.9 mm
15°
5°
0°
0.50 mm
2.9 mm
15°
5°
0°
0.50 mm
2.7 mm
6°
9°
0°
0.65 mm
3 mm
7°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
74.02.814IS 74.02.814IS 74.02.813IS 74.02.812IS 74.02.811IS 74.02.821IS 74.02.822IS 74.02.823IS 74.02.824IS 74.02.824IS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
7°
-3°
-3°
-3°
-3°
7°
-12°
-17°
4°
4°
5°
4°
2°
2°
4°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0. 15 mm
74.02.845IS
5
74.02.844IS
5
74.02.843IS
5
74.02.842IS
5
74.02.841IS
5
74.02.831IS
5
74.02.832IS
5
74.02.833IS
5
74.02.834IS
5
74.02.835IS
5
2.7 mm
-5°
9°
0°
0.65 mm
2.9 mm
2°
5°
0°
0.50 mm
2.9 mm
2°
5°
0°
0.50 mm
2.7 mm
-5°
9°
0°
0.65 mm
3 mm
-9°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
DAMON LOW TORQUE PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
74.02.900LI
Hooks on 3. 4 & 5
20 brackets
74.02.910LI - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
-9°
5°
4°
0.25 mm
74.02.814IS 74.02.814IS 74.02.813IL 74.02.812IL 74.02.811IL 74.02.821IL 74.02.822IL 74.02.823IL 74.02.824IS 74.02.824IS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
0°
-11°
-11°
-11°
-11°
0°
-12°
-17°
4°
4°
5°
4°
2°
2°
4°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0. 15 mm
74.02.845IS
5
74.02.844IS
5
74.02.843IL
5
74.02.842IL
5
74.02.841IL
5
74.02.831IL
5
74.02.832IL
5
74.02.833IL
5
74.02.834IS
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
8
74.02.835IS
5
Brackets-Self-Ligating
INTERACTIVE
DAMON HIGH TORQUE PRESCRIPTION
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
74.02.910AI/BI/CI - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
11°
5°
4°
0.25 mm
2.7 mm
13°
9°
0°
0.65 mm
2.9 mm
22°
5°
0°
0.50 mm
2.9 mm
22°
5°
0°
0.50 mm
2.7 mm
13°
9°
0°
0.65 mm
3 mm
11°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
74.02.814IS 74.02.814IS 74.02.813IH 74.02.812IH 74.02.811IH 74.02.821IH 74.02.822IH 74.02.823IH 74.02.824IS 74.02.824IS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-5°
13°
0°
0°
0°
0°
+13°
-5°
-17°
4°
4°
5°
0°
0°
0°
0°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0. 15 mm
74.02.845IS
5
74.02.844IH
5
74.02.843IH
5
74.02.841IH
5
74.02.841IH
5
74.02.841IH
5
74.02.841IH
5
74.02.833IH
5
74.02.834IH
5
74.02.835IS
5
2.7 mm
8°
9°
0°
0.65 mm
2.9 mm
12°
5°
0°
0.50 mm
2.9 mm
12°
5°
0°
0.50 mm
2.7 mm
8°
9°
0°
0.65 mm
3 mm
0°
11°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
ROTH PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.23.0390
Hooks on 3. 4 & 5
20 brackets
74.32.910I - Hooks on 3 .022
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
0°
11°
4°
0.25 mm
74.32.814I
74.32.814I
74.32.813I
74.32.812I
74.32.811I
74.32.821I
74.32.822I
74.32.823I
74.32.824I
74.32.824I
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-22°
-17°
-11°
0°
0°
0°
0°
-11°
-17°
-22°
0°
0°
5°
0°
0°
0°
0°
5°
0°
0°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.32.845I
5
74.32.844I
5
74.32.843I
5
74.32.841I
5
74.32.841I
5
74.32.841I
5
74.32.841I
5
74.32.833I
5
74.32.834I
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
9
74.32.835I
5
Brackets-^ĞůĨͲ>ŝŐĂƟŶŐ
INTERACTIVE
MBT PRESCRIPTION
Slot
.022" x .028"
Reference
05.23.0890
Hooks on 3. 4 & 5
20 brackets
74.82.910I - Hooks on 3 .022
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
8°
4°
0.25 mm
2.7 mm
10°
8°
0°
0.65 mm
2.9 mm
17°
4°
0°
0.50 mm
2.9 mm
17°
4°
0°
0.50 mm
2.7 mm
10°
8°
0°
0.65 mm
3 mm
-7°
8°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
05.23.0814
5
5
15
05.23.0814
5
4
14
05.23.0813
5
3
13
05.23.0812
5
2
12
05.23.0811
5
1
11
05.23.0821
5
1
21
05.23.0822
5
2
22
05.23.0823
5
3
23
05.23.0824
5
4
24
05.23.0824
5
5
25
45
5
3 mm
-17°
0°
4°
0.15 mm
44
4
3 mm
-12°
0°
4°
0.15 mm
43
3
2.9 mm
-6°
3°
2°
0.20 mm
42
2
2.7 mm
-6°
0°
0°
0.45 mm
41
1
2.7 mm
-6°
0°
0°
0.45 mm
31
1
2.7 mm
-6°
0°
0°
0.45 mm
32
2
2.7 mm
-6°
0°
0°
0.45 mm
33
3
2.9 mm
-6°
3°
2°
0.20 mm
34
4
3 mm
-12°
2°
4°
0.15 mm
35
5
3 mm
-17°
2°
4°
0.15 mm
05.23.0845
5
05.23.0844
5
05.23.0843
5
05.23.0841
5
05.23.0841
5
05.23.0841
5
05.23.0841
5
05.23.0833
5
05.23.0834
5
05.23.0835
5
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
FEATURES / BENEFITS
• Lowest profile on the market
• Thermal NiTi Clip / Planar design for easy opening
and secure engagement
Passive System
• Combines the best of both Passive and Interactive
treatment techniques with familiar geometric design
• System can be utilized as:
- Fully Passive
- Fully Interactive, or
- Combinations of both
• Allows orthodontists full control from start to finish
Interactive System
• More comfortable for patients
• Reduces friction and improves sliding mechanics
• Fewer patient visits compared to traditional brackets
• Open mini twin design for easy positioning reference
and maximum patient hygiene
Hybrid Systems
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
10
Brackets-Self-Ligating
HYBRID SYSTEM - Interactive .022" / Passive .022"
DAMON STANDARD PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
74.02.900SD
Hooks on 3. 4 & 5
20 brackets
74.02.910SD - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
7°
5°
4°
0.25 mm
2.7 mm
6°
9°
0°
0.65 mm
2.9 mm
15°
5°
0°
0.50 mm
2.9 mm
15°
5°
0°
0.50 mm
2.7 mm
6°
9°
0°
0.65 mm
3 mm
7°
5°
4°
0.25mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
74.02.814PS 74.02.814PS 74.02.813PS 74.02.812IS 74.02.811IS 74.02.821IS 74.02.822IS 74.02.823PS 74.02.824PS 74.02.824PS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
7°
-3°
-3°
-3°
-3°
7°
-12°
-17°
4°
4°
5°
-4°
2°
2°
4
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.02.845PS
5
74.02.844PS
5
74.02.843PS
5
74.02.842IS
5
74.02.841IS
5
74.02.831IS
5
74.02.832IS
5
74.02.833PS
5
74.02.834PS
5
74.02.835PS
5
2.7 mm
-5°
9°
0°
0.65 mm
2.9 mm
2°
5°
0°
0.50 mm
2.9 mm
2°
5°
0°
0.50 mm
2.7 mm
-5°
9°
0°
0.65 mm
3 mm
-9°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
-11°
2°
2°
0.25 mm
DAMON LOW TORQUE PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
74.02.900LD
Hooks on 3. 4 & 5
20 brackets
74.02.910LD - Hooks on 3 .022
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
-9°
5°
4°
0.25 mm
74.02.814PS 74.02.814PS 74.02.813PL 74.02.812IL 74.02.811IL 74.02.821IL 74.02.822IL 74.02.823PL 74.02.824PS 74.02.824PS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
0°
-11°
-11°
-11°
-11°
0°
-12°
-17°
4°
4°
5°
4°
2°
2°
4°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.02.845PS
5
74.02.844PS
5
74.02.843PL
5
74.02.842IL
5
74.02.841IL
5
74.02.831IL
5
74.02.832IL
5
74.02.833PL
5
74.02.834PS
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
11
74.02.835PS
5
Brackets-Self-Ligating
HYBRID SYSTEM - Interactive .022" / Passive .022"
DAMON HIGH TORQUE PRESCRIPTION
Slot
.022" x .028"
.022" x .028"
.022" x .028"
Reference
74.02.900AD
74.02.900BD
74.02.900CD
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Hooks on 3. 4 & 5
Teeth 41/31/42/32 0°T 0°A
Teeth 41/31 -3°T 2°A 42/32 -3°T 4°A
Teeth 41/31/42/32 -6°T 2°A
3 mm
-11°
2°
2°
0.25 mm
3 mm
-11°
2°
2°
0.25 mm
3 mm
11°
5°
4°
0.25 mm
2.7 mm
13°
9°
0°
0.65 mm
Kit variations:
2.9 mm
22°
5°
0°
0.50 mm
2.9 mm
22°
5°
0°
0.50 mm
74.02.910AD/BD/CD - Hooks on 3 .022
2.7 mm
13°
9°
0°
0.65 mm
3 mm
11°
5°
4°
0.25 mm
3 mm
-11°
2°
2°
0.25mm
3 mm
-11°
2°
2°
0.25 mm
74.02.814PS 74.02.814PS 74.02.813PH 74.02.812IH 74.02.811IH 74.02.821IH 74.02.822IH 74.02.823PH 74.02.824PS 74.02.824PS
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-5°
13°
0°
0°
0°
0°
13°
-5°
-17°
4°
4°
5°
0°
0°
0°
0°
5°
4°
4°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.02.845PS
5
74.02.844PH
5
74.02.843PH
5
74.02.841IH
5
74.02.841IH
5
74.02.841IH
5
74.02.841IH
5
74.02.833PH
5
74.02.834PH
5
74.02.835PS
5
2.7 mm
8°
9°
0°
0.65 mm
2.9 mm
12°
5°
0°
0.50 mm
2.9 mm
12°
5°
0°
0.50 mm
2.7 mm
8°
9°
0°
0.65 mm
3 mm
0°
11°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
ROTH PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.25.0390
Hooks on 3. 4 & 5
20 brackets
74.32.910D - Hooks on 3 .022
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
0°
11°
4°
0.25 mm
74.32.814P
74.32.814P
74.32.813P
74.32.812I
74.32.811I
74.32.821I
74.32.822I
74.32.823P
74.32.824P
74.32.824P
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-22°
-17°
-11°
0°
0°
0°
0°
-11°
-17°
-22°
0°
0°
5°
0°
0°
0°
0°
5°
0°
0°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.32.845P
5
74.32.844P
5
74.32.843P
5
74.32.841I
5
74.32.841I
5
74.32.841I
5
74.32.841I
5
74.32.833P
5
74.32.834P
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
12
74.32.835P
5
Brackets-^ĞůĨͲ>ŝŐĂƟŶŐ
HYBRID SYSTEM - Interactive .022" / Passive .022"
MBT PRESCRIPTION
Slot
.022" x .028"
Reference
05.25.0890
Hooks on 3. 4 & 5
20 brackets
74.82.910D - Hooks on 3 .022
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
8°
4°
0.25 mm
2.7 mm
10°
8°
0°
0.65 mm
2.9 mm
17°
4°
0°
0.50 mm
2.9 mm
17°
4°
0°
0.50 mm
2.7 mm
10°
8°
0°
0.65 mm
3 mm
-7°
8°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
74.82.814P
5
5
15
74.82.814P
5
4
14
74.82.813P
5
3
13
74.82.812I
5
2
12
74.82.811I
5
1
11
74.82.821I
5
1
21
74.82.822I
5
2
22
74.82.823P
5
3
23
74.82.824P
5
4
24
74.82.824P
5
5
25
45
5
3 mm
-17°
0°
4°
0.15 mm
44
4
3 mm
-12°
0°
4°
0.15 mm
43
3
2.9 mm
-6°
3°
2°
0.20 mm
42
2
2.7 mm
-6°
0°
0°
0.45 mm
41
1
2.7 mm
-6°
0°
0°
0.45 mm
31
1
2.7 mm
-6°
0°
0°
0.45 mm
32
2
2.7 mm
-6°
0°
0°
0.45 mm
33
3
2.9 mm
-6°
3°
2°
0.20 mm
34
4
3 mm
-12°
2°
4°
0.15 mm
35
5
3 mm
-17°
2°
4°
0.15 mm
74.82.845P
5
74.82.844P
5
74.82.843P
5
74.82.841I
5
74.82.841I
5
74.82.841I
5
74.82.841I
5
74.82.833P
5
74.82.834P
5
74.82.835P
5
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
To learn more about EasyClip+ and our
complete line of brackets, visit our interactive
bracket website or contact us today!
www.GreatLakesBrackets.com
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
13
Brackets-Self-Ligating
HYBRID DUAL SLOT SYSTEM - Interactive .018" / Passive .022"
ROTH PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.25.0390B
Hooks on 3. 4 & 5
20 brackets
74.32.910DB - Hooks on 3 .022
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
0°
11°
4°
0.25 mm
2.7 mm
8°
9°
0°
0.65 mm
2.9 mm
12°
5°
0°
0.50 mm
2.9 mm
12°
5°
0°
0.50 mm
2.7 mm
8°
9°
0°
0.65 mm
3 mm
0°
11°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
74.32.814P
74.32.814P
74.32.813P
74.31.812I
74.31.811I
74.31.821I
74.31.822I
74.32.823P
74.32.824P
74.32.824P
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-22°
-17°
-11°
0°
0°
0°
0°
-11°
-17°
-22°
0°
0°
5°
0°
0°
0°
0°
5°
0°
0°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.32.845P
5
74.32.844P
5
74.32.843P
5
74.31.841I
5
74.31.841I
5
74.31.841I
5
74.31.841I
5
74.32.833P
5
74.32.834P
5
74.32.835P
5
2.7 mm
10°
8°
0°
0.65 mm
2.9 mm
17°
4°
0°
0.50 mm
2.9 mm
17°
4°
0°
0.50 mm
2.7 mm
10°
8°
0°
0.65 mm
3 mm
-7°
8°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
MBT PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.25.0890B
Hooks on 3. 4 & 5
20 brackets
74.02.910LD - Hooks on 3 .022
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
8°
4°
0.25 mm
74.82.814P
74.82.814P
74.82.813P
74.81.812I
74.81.811I
74.81.821I
74.81.822I
74.82.823P
74.82.824P
74.82.824P
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
-6°
-6°
-6°
-6°
-6°
-6°
-12°
-17°
2°
2°
3°
0°
0°
0°
0°
3°
2°
2°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.82.845P
5
74.82.844P
5
74.82.843P
5
74.81.841I
5
74.81.841I
5
74.81.841I
5
74.81.841I
5
74.82.833P
5
74.82.834P
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
14
74.82.835P
5
Brackets-Self-Ligating
INTERACTIVE DUAL SLOT SYSTEM - Interactive .018" / Interactive .022"
ROTH PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.23.0390B
Hooks on 3. 4 & 5
20 brackets
7 4.32.910IB - Hooks on 3 .022
3 mm
3 mm
3 mm
-7°
-7°
0°
0°
0°
11°
2°
2°
4°
0.25 mm
0.25 mm
0.25 mm
2.7 mm
8°
9°
0°
0.65 mm
2.9 mm
12°
5°
0°
0.50 mm
2.9 mm
12°
5°
0°
0.50 mm
2.7 mm
8°
9°
0°
0.65 mm
3 mm
0°
11°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
74.32.814I
74.32.814I
74.32.813I
74.31.812I
74.31.811I
74.31.821I
74.31.822I
74.32.823I
74.32.824I
74.32.824I
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-22°
-17°
-11°
0°
0°
0°
0°
-11°
-17°
-22°
0°
0°
5°
0°
0°
0°
0°
5°
0°
0°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.32.845I
5
74.32.844I
5
74.32.843I
5
74.31.841I
5
74.31.841I
5
74.31.841I
5
74.31.841I
5
74.32.833I
5
74.32.834I
5
74.32.835I
5
2.7 mm
10°
8°
0°
0.65 mm
2.9 mm
17°
4°
0°
0.50 mm
2.9 mm
17°
4°
0°
0.50 mm
2.7 mm
10°
8°
0°
0.65 mm
3 mm
-7°
8°
4°
0.25 mm
3 mm
-7°
0°
2°
0.25mm
3 mm
-7°
0°
2°
0.25 mm
MBT PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
Reference
05.23.0890B
Hooks on 3. 4 & 5
20 brackets
74.82.910IB - Hooks on 3 .022
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
0°
2°
0.25 mm
3 mm
-7°
8°
4°
0.25 mm
74.82.814I
74.82.814I
74.82.813I
74.81.812I
74.81.811I
74.81.821I
74.81.822I
74.82.823I
74.82.824I
74.82.824I
5
5
5
5
5
5
5
5
5
5
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
length
torque
angle
Off
In-out
Replacement
.022" x .028"
Slot
quantity
45 4443 424131 323334 35
5 43 211 234 5
3 mm
3 mm
2.9 mm
2.7 mm
2.7 mm
2.7 mm
2.7 mm
2.9 mm
3 mm
3 mm
-17°
-12°
-6°
-6°
-6°
-6°
-6°
-6°
-12°
-17°
0°
0°
3°
0°
0°
0°
0°
3°
2°
2°
4°
4°
2°
0°
0°
0°
0°
2°
4°
4°
0.15 mm
0.15 mm
0.20 mm
0.45 mm
0.45 mm
0.45 mm
0.45 mm
0.20 mm
0.15 mm
0.15 mm
74.82.845I
5
74.82.844I
5
74.82.843I
5
74.81.841I
5
74.81.841I
5
74.81.841I
5
74.81.841I
5
74.82.833I
5
74.82.834I
5
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
15
74.82.835I
5
Great Lakes
BioTru™
Classic
Completely programmed for a
true straight wire system that
positions teeth at all four levels:
In/Out • Angulations
Torque • Overcorrection
Bracket System
Center scribe line aligns
with the long axis for
accurate placement
17-4 PH stainless steel
for higher strength
Full rotational control
due to mesial to distal
width and twin design
ID color coding for easy
bracket selection
Microcast - consistent,
exact tolerances
Anatomical
hook
Compound contour
base for easy,
accurate placement
Ample tie-wing
undercuts to
facilitate ligation
BENEFITS
Rounded
tie wings
for patient
comfort
Torque in base
for level slot
lineup and
improved
finishing
Diamond-shaped
geometry for
accurate
placement
• 4-Dimensional appliance bracket
needs no offset bends in the
archwire to obtain an optimal finish.
• Torque in base designed to provide
level slot lineup, and helps avoid
occlusal interference.
• Foil mesh bonding pad matches
the curvature of the tooth for
maximum contact and a strong,
consistent bond.
• Special option available for bicuspid
brackets that feature a gingivally
offset bonding base.
CHARACTERISTICS
• Rounded tie wings for patient
comfort (Standard size)
• Color-coded enhanced ID for easy
bracket selection
• Lowest possible profile without
compromising the straight wire
characteristics of the system
• Manufactured from 17-4 PH
surgical grade stainless steel
• Standardized In/Outs for precision
and consistency
• Diamond-shaped tie-wings are
parallel to the tooth anatomy for
accurate placement
• Vertical aspects follow the long axis
of the tooth - Horizontal aspects run
parallel to the occlusal plane
• Twin design for full rotational
control
• Palladium brazing alloy for
maximum solder joint strength
• .080 mesh pad for increased
bond strength
• 100% quality check ensures exact
slot tolerances
.080 mesh base
for increased bond
strength
APPLICATIONS
• This classic bracket system
combines the concepts of
traditional orthodontics with the
latest engineering and production
processes.
• Professionals have the ability to
choose from a wide range of
treatment options and protocols to
best meet the needs of your clients
and your practice.
• Ideal for all treatment patterns as
brackets can be interchanged within
prescriptions.
• All bracket prescriptions utilize the
same In/Out for slot level alignment
and interchangeability.
• Provides doctors with full control
from start to finish with a completely
adjusted straight wire appliance.
AVAILABLE
PRESCRIPTIONS
• Roth
• MBT
.018" and .022" Slots
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
16
Brackets
BioTru™ Classic
ROTH PRESCRIPTION
Slot
.022" x .028"
.018" x .028"
Kit variations:
length
Torque
angle
Replacement
.022" x .028"
.018" x .028"
Slot
quantity
Reference
05.10.0390
05.09.0390
Hooks on 3. 4 & 5
20 brackets
20 brackets
12.32.910 - Hooks on 3 .022
12.31.910 - Hooks on 3 .018
12.32.901 - Kit Offset Hooks on 3/4/5 .022
12.31.901 - Kit Offset Hooks on 3/4/5 .018
3.2 mm
-7°
0°
3.2 mm
-7°
0°
3.5 mm
0°
11°
3.2 mm
8°
9°
3.9 mm
12°
5°
3.9 mm
12°
5°
3.2 mm
8°
9°
3.5 mm
0°
11°
3.2 mm
-7°
0°
3.2 mm
-7°
0°
05.10.0314
05.09.0314
10
5
15
05.10.0314
05.09.0314
10
4
14
05.10.0313
05.09.0313
10
3
13
05.10.0312
05.09.0312
10
2
12
05.10.0311
05.09.0311
10
1
11
05.10.0321
05.09.0321
10
1
21
05.10.0322
05.09.0322
10
2
22
05.10.0323
05.09.0323
10
3
23
05.10.0324
05.09.0324
10
4
24
05.10.0324
05.09.0324
10
5
25
45
5
3.3 mm
-22°
0°
44
4
3.3 mm
-17°
0°
43
3
3.5 mm
-11°
5°
42
2
2.5 mm
0°
0°
41
1
2.5 mm
0°
0°
31
1
2.5 mm
0°
0°
32
2
2.5 mm
0°
0°
33
3
3.5 mm
-11°
5°
34
4
3.3 mm
-17°
0°
35
5
3.3 mm
-22°
0°
05.10.0345
05.09.0345
10
05.10.0344
05.09.0344
10
05.10.0343
05.09.0343
10
05.10.0341
05.09.0341
10
05.10.0341
05.09.0341
10
05.10.0341
05.09.0341
10
05.10.0341
05.09.0341
10
05.10.0333
05.09.0333
10
05.10.0334
05.09.0334
10
05.10.0335
05.09.0335
10
Upper
Lower
length
Torque
angle
Replacement
.022" x .028"
Slot
.018" x .028"
quantity
MBT PRESCRIPTION
Slot
.022" x .028"
.018" x .028"
Kit variations:
length
Torque
angle
Replacement
.022" x .028"
Slot
.018" x .028"
quantity
Reference
05.10.0890
05.09.0890
Hooks on 3. 4 & 5
20 brackets
20 brackets
12.82.910 - Hooks on 3 .022
12.81.910 - Hooks on 3 .018
12.82.901 - Kit Offset Hooks on 3/4/5 .022
12.81.901 - Kit Offset Hooks on 3/4/5 .018
3.2 mm
-7°
0°
3.2 mm
-7°
0°
3.5 mm
-7°
8°
3.2 mm
10°
8°
3.9 mm
17°
4°
3.9 mm
17°
4°
3.2 mm
10°
8°
3.5 mm
-7°
8°
3.2 mm
-7°
0°
3.2 mm
-7°
0°
05.10.0814
12.81.514
10
5
15
05.10.0814
12.81.514
10
4
14
05.10.0813
05.09.0813
10
3
13
05.10.0812
05.09.0812
10
2
12
05.10.0811
05.09.0811
10
1
11
05.10.0821
05.09.0821
10
1
21
05.10.0822
05.09.0822
10
2
22
05.10.0823
05.09.0823
10
3
23
05.10.0824
12.81.524
10
4
24
05.10.0824
12.81.524
10
5
25
45
5
3.3 mm
-17°
0°
44
4
3.3 mm
-12°
0°
43
3
3.5 mm
-6°
3°
42
2
2.5 mm
-6°
0°
41
1
2.5 mm
-6°
0°
31
1
2.5 mm
-6°
0°
32
2
2.5 mm
-6°
0°
33
3
3.5 mm
-6°
3°
34
4
3.3 mm
-12°
0°
35
5
3.3 mm
-17°
0°
05.10.0845
05.09.0845
10
05.10.0844
05.09.0844
10
05.10.0843
05.09.0843
10
05.10.0841
05.09.0841
10
05.10.0841
05.09.0841
10
05.10.0841
05.09.0841
10
05.10.0841
05.09.0841
10
05.10.0833
05.09.0833
10
05.10.0834
05.09.0834
10
05.10.0835
05.09.0835
10
Upper
Lower
length
Torque
angle
Replacement
.022" x .028"
Slot
.018" x .028"
quantity
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
17
Great Lakes
BioTru
A unique combination of
aesthetics, function,
and strength.
™
Ceramic
Bracket System
Diamond polished
archwire slot
increases torque
control and sliding
mechanics
Smooth, rounded
corners for added
patient comfort
Blends with natural
tooth tone
Ample clearance
under tie wings
Polycrystalline Alumina
is highly stain resistant
Low profile
Dovetail
base design
debonds easily
BENEFITS
• Dovetail base design has an
interlocking adhesive tooth interface
for maximum bond strength, yet
debonds easily when needed.
• Bracket design and ceramic
material are engineered for
exceptional bond strength and
fracture resistance.
APPLICATIONS
• Precision cut, diamond polished
slots increase torque control and
sliding mechanics.
• Utilized in patients where aesthetics
and cosmetic needs, as well as
financial requirements, are a concern.
• Made from 99.9% pure
Polycrystalline Alumina ensures
the translucency patients want.
• Provides an invisible, stain resistant
appearance throughout the treatment.
- Coated steel ligature ties
- Coated springs and clear
elastic ligature ties
CHARACTERISTICS
• Translucency blends with the
natural tooth tone
• Removable color-coded ID dot
for easy bracket selection
• Does not require any special
instruments or adhesive for
routine protocol use
• Utilizes smooth polished
surfaces, rounded corners,
and contoured auxiliary hooks
for added patient comfort
• Easy ligation for ligatures
and accessories with ample
clearance under tie wings
• Rhomboid shape for accurate
placement
• To enhance overall aesthetics, the
following auxiliaries are provided:
AVAILABLE
PRESCRIPTIONS
• Roth
• MBT
.018" and .022" Slots
• Six distinct shapes of foil
mesh pad for perfect tooth
anatomy fitting
• Vertical aspects follow the long axis
of the tooth - Horizontal aspects run
parallel to the occlusal plane
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
18
Brackets-Aesthetic
BioTru™ Ceramic
ROTH PRESCRIPTION
Slot
.022" x .028"
.018" x .028"
length
Torque
angle
Replacement
.022" x .028"
Slot
.018" x .028"
quantity
Reference
05.03.0390
05.02.0390
Hooks on 3. 4 & 5
20 brackets
20 brackets
3.2 mm
-7°
0°
3.2 mm
-7°
0°
3.3 mm
0°
11°
3.2 mm
8°
9°
3.6 mm
12°
5°
3.6 mm
12°
5°
3.2 mm
8°
9°
3.3 mm
0°
11°
3.2 mm
-7°
0°
3.2 mm
-7°
0°
05.03.0314
05.02.0314
1
05.03.0314
05.02.0314
1
05.03.0313
05.02.0313
1
05.03.0312
05.02.0312
1
05.03.0311
05.02.0311
1
05.03.0321
05.02.0321
1
05.03.0322
05.02.0322
1
05.03.0323
05.02.0323
1
05.03.0324
05.02.0324
1
05.03.0324
05.02.0324
1
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
45 4443 424131 323334 35
5 43 211 234 5
length
Torque
angle
Replacement
Slot
.022" x .028"
.018" x .028"
quantity
3.2 mm
-22°
0°
3.2 mm
-17°
0°
3.4mm
-11°
5°
2.9 mm
0°
0°
2.9 mm
0°
0°
2.9 mm
0°
0°
2.9 mm
0°
0°
3.4 mm
-11°
5°
3.2 mm
-17°
0°
3.2 mm
-22°
0°
05.03.0345
05.02.0345
1
05.03.0344
05.02.0344
1
05.03.0343
05.02.0343
1
05.03.0341
05.02.0341
1
05.03.0341
05.02.0341
1
05.03.0341
05.02.0341
1
05.03.0341
05.02.0341
1
05.03.0333
05.02.0333
1
05.03.0334
05.02.0334
1
05.03.0335
05.02.0335
1
MBT PRESCRIPTION
Slot
.022" x .028"
Kit variations:
length
Torque
angle
Replacement
.022" x .028"
Slot
quantity
Reference
05.03.0890
Hooks on 3. 4 & 5
20 brackets
15.82.910M - Kit Hooks on 3 .022
3.2 mm
-7°
0°
3.2 mm
-7°
0°
3.3 mm
-7°
8°
3.2 mm
10°
8°
3.6 mm
17°
4°
3.6 mm
17°
4°
3.2 mm
10°
8°
3.3 mm
-7°
8°
3.2 mm
-7°
0°
3.2 mm
-7°
0°
05.03.0814
1
05.03.0814
1
05.03.0813
1
05.03.0812
1
05.03.0811
1
05.03.0821
1
05.03.0822
1
05.03.0823
1
05.03.0824
1
05.03.0824
1
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
45 4443 424131 323334 35
5 43 211 234 5
length
Torque
angle
Replacement
.022" x .028"
Slot
quantity
3.2 mm
-17°
0°
3.2 mm
-12°
0°
3.4mm
-6°
3°
2.9 mm
-6°
0°
2.9 mm
-6°
0°
2.9 mm
-6°
0°
2.9 mm
-6°
0°
3.4 mm
-6°
3°
3.2 mm
-12°
0°
3.2 mm
-17°
0°
05.03.0845
1
05.03.0844
1
05.03.0843
1
05.03.0841
1
05.03.0841
1
05.03.0841
1
05.03.0841
1
05.03.0833
1
05.03.0834
1
05.03.0835
1
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
19
Great Lakes
BioTru
The ultimate in crystal
clear aesthetics - highest
transparency available
™
Sapphire
Bracket System
Smooth rounded
corners for added
patient comfort
Diamond polished
archwire slot
improves sliding
mechanics
Low profile design
and small bracket size
Monocrystalline Sapphire
does not stain
Bond strength
enhanced by
Zirconia spheres
Contoured base
allows quick and
easy placement
Easy-to-ligate
tie wings
BENEFITS
• Invisible against any tooth shade
and remains crystal clear without
staining.
• Diamond polishing/finishing process
produces rounded, smooth corners
for uncompromised patient comfort.
• Exceptionally strong and highly
fracture resistant, but also
functional with easy-to-ligate
tie wings.
CHARACTERISTICS
• Made from 100% Monocrystalline
Sapphire
• Smooth, strong, and contoured
tie wings
• Diamond polished archwire slot
for superior sliding mechanics
• Ultra-smooth strong hooks provide
comfortable, secure engagement
of elastics
• Contoured bonding base
APPLICATIONS
• Bond strength is provided by a
Zirconia sphere coated base,
creating millions of undercuts that
mechanically lock with the bracket
adhesive.
• Secure retention during the length
of treatment and predictable
debonding at the end of treatment.
• Anatomically contoured toothspecific design fits the tooth
curvatures perfectly to increase
bond strength.
• Unique bonding base: Zirconia
spheres provide super shear
bond strength and predictable
debonding
• For patients who demand the highest
standards in aesthetically cosmetic
bracket systems.
• Recommended to be utilized with
Tooth Tone coated archwires,
auxiliaries, and clear elastomeric
ligature ties for maximum aesthetics.
• Small bracket size and low profile
design is ideal for both clinicians
and patients.
AVAILABLE
PRESCRIPTIONS
• Roth
• MBT
.018" and .022" Slots
• Removable ID color-coded
dot and slot marking for visible
reference and accurate bracket
placement
• Utilizes smooth polished surfaces,
rounded corners, and contoured
auxiliary hooks for added patient
comfort
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
20
Brackets-Aesthetic
BioTru™ Sapphire
ROTH PRESCRIPTION
Slot
.022" x .028"
.018" x .028"
length
Torque
angle
Replacement
.022" x .028"
Slot
.018" x .028"
quantity
Reference
05.15.0390
05.16.0390
Hooks on 3. 4 & 5
20 brackets
20 brackets
3.3 mm
-7 °
0°
3.3 mm
-7°
0°
3.3 mm
0°
11°
2.7 mm
8°
9°
3.1 mm
12°
5°
3.1 mm
12°
5°
2.7 mm
8°
9°
3.3 mm
0°
11°
3.3 mm
-7°
0°
3.3 mm
-7°
0°
05.15.0314
05.16.0314
1
05.15.0314
05.16.0314
1
05.15.0313
05.16.0313
1
05.15.0312
05.16.0312
1
05.15.0311
05.16.0311
1
05.15.0321
05.16.0321
1
05.15.0322
05.16.0322
1
05.15.0323
05.16.0323
1
05.15.0324
05.16.0324
1
05.15.0324
05.16.0324
1
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
45 4443 424131 323334 35
5 43 211 234 5
length
Torque
angle
Replacement
.022" x .028"
Slot
.018" x .028"
quantity
3.3 mm
-22°
0°
3.3 mm
-17°
0°
3.2 mm
-11°
5°
2.6 mm
0°
0°
2.6 mm
0°
0°
2.6 mm
0°
0°
2.6 mm
0°
0°
3.2 mm
-11°
5°
3.3 mm
-17°
0°
3.3 mm
-22°
0°
05.15.0345
05.16.0345
1
05.15.0344
05.16.0344
1
05.15.0343
05.16.0343
1
05.15.0341
05.16.0341
1
05.15.0341
05.16.0341
1
05.15.0341
05.16.0341
1
05.15.0341
05.16.0341
1
05.15.0333
05.16.0333
1
05.15.0334
05.16.0334
1
05.15.0335
05.16.0335
1
MBT PRESCRIPTION
Slot
.022" x .028"
length
Torque
angle
Replacement
.022" x .028"
Slot
quantity
Reference
05.15.0890
Hooks on 3. 4 & 5
20 brackets
3.3 mm
-7
0
3.3 mm
-7
0
3.3 mm
-7
8
2.7 mm
10
8
3.1 mm
17
4
3.1 mm
17
4
2.7 mm
10
8
3.3 mm
-7
8
3.3 mm
-7
0
3.3 mm
-7
0
05.15.0814
1
05.15.0814
1
05.15.0813
1
05.15.0812
1
05.15.0811
1
05.15.0821
1
05.15.0822
1
05.15.0823
1
05.15.0824
1
05.15.0824
1
5 43 211 234 5
15 1413 121121 222324 25
Upper
Lower
45 4443 424131 323334 35
5 43 211 234 5
length
Torque
angle
Replacement
.022" x .028"
Slot
quantity
3.3 mm
-17°
0°
3.3 mm
-12°
0°
3.2 mm
-6°
3°
2.6 mm
-6°
0°
2.6 mm
-6°
0°
2.6 mm
-6°
0°
2.6 mm
-6°
0°
3.2 mm
-6°
3°
3.3 mm
-12°
0°
3.3 mm
-17°
0°
05.15.0845
1
05.15.0844
1
05.15.0843
1
05.15.0841
1
05.15.0841
1
05.15.0841
1
05.15.0841
1
05.15.0833
1
05.15.0834
1
05.15.0835
1
Great Lakes’ version of the Roth and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
21
Great Lakes
BioMax ®
A true Straight Wire system
offering efficiency, affordability,
and patient satisfaction
Bracket System
17-4 PH stainless steel
MIM manufacturing for
increased strength
‘V’ channel aligns
with the long axis
for accurate placement
Angulated slot for
easy wire insertion
ID color coding for
easy bracket selection
Full rotational control
due to mesial to distal
width and twin design
Rounded tie wings
for patient comfort
Triple chamfered slot
walls lessen binding
Rhomboid shape
with low profile
design for patient
comfort and secure
bonding
Ample tie-wing
undercuts to
facilitate ligation
State-of-the-art
anatomical base
design
Mushroom-shaped pylons
create undercuts for
maximum bond strength
BENEFITS
• Establishes a new standard for
quality and affordability.
• A Straight Wire bracket system with
rounded contours for greater
patient comfort.
APPLICATIONS
• Generous under tie-wing areas
facilitate ligation with either
elastomeric or steel ligature ties.
• Center scribe ‘V’ channel aligns
with the long axis for accurate
placement and easy removal of
ligature ties.
• Designed for error-free bonding
positioning due to reference
cues with tie wings parallel to the
tooth anatomy.
• The central ‘V’ channel parallel to the
long axis of the clinical
crown ensures accurate placement.
• Promotes faster ligature tie
engagement and removal.
CHARACTERISTICS
• One piece metal injection molded
(MIM) brackets
• Faster placement and removal of
ligature ties
• Fully programmed tooth-shaped
designed brackets. A true Straight
Wire system
• Low profile and rounded contour
design for patient comfort
• Compound contour base for
optimal bonding
• Central ‘V’ channel for positioning
bonding reference and faster
ligature tie removal
• Micro-etched base for optimal
bond strength
• ID marking system
on the bracket tie wings
• Provides excellent productivity and
patient satisfaction at an affordable
cost.
AVAILABLE
PRESCRIPTIONS
• Roth
.022" Slots
• Offset bicuspid bases avoid
occlusal interferences
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
22
Brackets
BioMax®
ROTH PRESCRIPTION
Slot
.022" x .028"
Kit variations:
Reference
05.04.0390
Hooks on 3. 4 & 5
20 brackets
05.04.0395 - Hooks on 100 cases
05.04.0394 - Hooks on 10 cases
72.32.910 - Hooks on 3 .022
length
Torque
angle
Replacement
.022" x .028"
Slot
quantity
2.8 mm
-7°
0°
2.8 mm
-7°
0°
2.8 mm
0°
11°
2.6 mm
8°
9°
3.20 mm
12°
5°
3.20 mm
12°
5°
2.6 mm
8°
9°
2.8 mm
0°
11°
2.8 mm
-7°
0°
2.8 mm
-7°
0°
05.04.0314
10
05.04.0314
10
05.04.0313
10
05.04.0312
10
05.04.0311
10
05.04.0321
10
05.04.0322
10
05.04.0323
10
05.04.0324
10
05.04.0324
10
5
4
3
2
1
1
2
3
4
5
15
14
13
12
11
21
22
23
24
25
Upper
Lower
length
Torque
angle
Replacement
.022" x .028"
Slot
quantity
45
44
43
42
41
31
32
33
34
35
5
4
3
2
1
1
2
3
4
5
2.8 mm
-22°
0°
2.8 mm
-17°
0°
2.8 mm
-11°
5°
2.3 mm
0°
0°
2.3 mm
0°
0°
2.3 mm
0°
0°
2.3 mm
0°
0°
2.8 mm
-11°
5°
2.8 mm
-17°
0°
2.8 mm
-22°
0°
05.04.0345
10
05.04.0344
10
05.04.0343
10
05.04.0341
10
05.04.0341
10
05.04.0341
10
05.04.0341
10
05.04.0333
10
05.04.0334
10
05.04.0335
10
Great Lakes’ version of the Roth prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
23
Great Lakes
BioTru™
Archwires
BioTru
NiTi
™
BENEFITS
APPLICATIONS
CHARACTERISTICS
• First archwire of choice
for early- and mid-stages
of treatment
• Used in alignment and
leveling phases with
conventional brackets
• Light-to-moderate forces
• Force exerted is light and
solid, enhancing patient
comfort
• Early treatment stages
using round wires Intermediate stages using
rectangular wires
• Easier ligation without
permanent deformation
• Can be used in all
phases of orthodontic
treatment
• Eases engagement into
brackets due to greater
flexibility
• Force modules specifically
calibrated for self-ligating
brackets
• High resiliency to deformation
• Performs best in the
initial stages of treatment
• Pre-installed stops help
prevent wire shifting
during treatment
• Provides lower initial load
forces and increased
residual forces as full shape
recovery progresses
• Calibrated for use with
self-ligating brackets
• Easier wire engagement
and biocompatible force
transmission
• Teeth move farther and faster
with lower force modules
• Ideal for early and
intermediate stages
of treatment
• Excellent shape recovery
Available sizes:
.012, .014, .016, .018, .020, .016x.016,
.016x.022, .016x.025, .017x.025, .018x.018,
.018x.025, .019x.025, .021x.025
BioTru
Copper
™
• Bright surface finish
and elasticity
Available in Super Elastic and Thermal
• Lowest power module
enables integration within
the same slots for
misaligned and uneven
cases
• Unique copper alloy
enhances thermal
properties and flexibility
• Transition temperatures
of 27°C
Available sizes:
.013, .014, .016, .018, .014x.025, .016x.025,
.018x.025
BioTru
Contour
™
• Can also be used with
conventional brackets
• Extreme flexibility at room
temperature
• Full shape recovery stays active to the end
• Transition temperatures
of 27°C
Available sizes:
.013, .014, .016, .018, .014x.025, .016x.025,
.017x.025, .018x.025, .019x.025
BioTru
Beta
Titanium*
™
• Provides force levels 45%
less than equivalent
stainless steel
• Moderate tooth-moving
force makes it ideal for
mid-to-late stage treatment
• Ideal for expressing
torque of inclination and
angulation
• Excellent formability for
loop placement and bends
• Bendability aids in custom
tipping, aligning, space
closure, rotation correction,
and tooth movement
• High friction material
• Nickel free for patients
with metal allergies
• Combines bendability
of stainless steel with
the flexibility of NiTi
• Accepts folds and
adjustments
Available sizes:
.016x.022, .017x.025, .019x.025
*Compares to TMA, a registered trademark of
Ormco Corporation.
24
BENEFITS
APPLICATIONS
CHARACTERISTICS
• Extremely high tensile
strength and malleability
• Ideal for detailing, finishing,
and consolidating the dental
arch
• High luster polish and
consisent surface for
reduced friction
• Accepts 1st, 2nd, and 3rd
order folds
• Biocompatible surgical
stainless steel offers
consistent shape and
power modules
• Used for extraction space
closure, Class II without
extraction, and anterior
intrusion/anterior
retraction
• Smooth surface and glossy
finish
• Accepts intricate bends
for torquing without breaking
BioTru
Stainless
Steel
™
• Excellent for the final stages
of treatment
Available sizes:
.012, .014, .016, .018, .020, .016x.016,
.016x.022, .016x.025, .017x.025, .018x.018,
.018x.025, .019x.025, .021x.025
Double Key
4 Double Key
BioTru
Retraction
™
T-Loop Double Key
Arch Sizes: 22 mm, 24 mm, 26 mm, 28 mm,
30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm,
42 mm, 44 mm
Available sizes:
.016x.022, .017x.025, .018x.025, .019x.025,
.021x.025
• Biocompatible surgical
stainless steel offers
consistent shape and
power modules. T-Loop is
also available in Beta
Titanium.
• High tensile strength
and malleability
• Quickly and efficiently opens
or closes the bite
™
• Accepts folds and
adjustments
• Used in sliding mechanics
for space closure
• Provides excellent
counterforces to achieve
bite and occlusal plane
modifications
BioTru
Reverse
Curve of Spee
• Commonly used in
combination with elastics
or closed springs
• Consistent activation force
• Prevents molar tipping and
rotation
• Maintains anterior torque
• Used for initial leveling and
aligning
• Corrects deep and open
bites
• Retracts flared, protruding
incisors
Available sizes:
.012, .014, .016, .018, .020, .016x.016,
.016x.022, .017x.025, .018x.025, .019x.025,
.021x.025
• Three Reverse Curve of Spee
(RCS) Shapes:
RCS 1: Offers a deeper “rocking
chair” radius exerting ideal forces
to reverse the Spee Curve for
severe cases of open or deep
bites
RCS 3: Provides a “shallower”
radius and lighter force than
RCS 1. Easier to ligate with
gentler, more comfortable tooth
movement
RCS 5: Straight leg buccal
segments do not toe-in the
molars; they help tilt them
back for anchorage purposes.
Easily places Curve of Spee
on the upper arch and can
torque the molars buccally.
Intrusion or extrusion of anterior
teeth can also be accomplished.
When flipped, it can be used to
expand the lower arch.
• High quality surface finish
25
BioTru™ NiTi
Archwires
SUPER ELASTIC
Natural
SIZE
.012
.014
.016
.018
.020
.016x.016
.016X.022
.017X.025
.018X.025
.019X.025
.021X.025
UPPER (10/Pkg.)
09.15.0512
09.15.0514
09.15.0516
09.15.0518
09.15.0520
09.15.0566
09.15.0562
09.15.0575
09.15.0585
09.15.0595
09.15.0525
LOWER (10/Pkg.)
09.15.0612
09.15.0614
09.15.0616
09.15.0618
09.15.0620
09.15.0666
09.15.0662
09.15.0675
09.15.0685
09.15.0695
09.15.0625
Europa I
SIZE
.014
.016
.018
.020
.016X.016
.016X.022
.017X.025
.018X.025
.019X.025
.021X.025
UPPER (10/Pkg.)
09.15.0314
09.15.0316
09.15.0318
09.15.0320
09.15.0366
09.15.0362
09.15.0375
09.15.0385
09.15.0395
09.15.0325
LOWER (10/Pkg.)
09.15.0414
09.15.0416
09.15.0418
09.15.0420
09.15.0466
09.15.0462
09.15.0475
09.15.0485
09.15.0495
09.15.0425
Reverse Curve
SIZE
.012
.014
.016
.018
.020
.016x.016
.016X.022
.017X.025
.018X.025
.019X.025
.021X.025
UPPER (10/Pkg.)
09.23.0512
09.23.0514
09.23.0516
09.23.0518
09.23.0520
09.23.0566
09.23.0562
09.23.0575
09.23.0585
09.23.0595
09.23.0525
THERMAL
Natural
SIZE
.014
.016
.018
.020
.016x.016
.016X.022
.017X.025
.018X.025
.019X.025
.021X.025
UPPER (10/Pkg.)
09.16.0514
09.16.0516
09.16.0518
09.16.0520
09.16.0566
09.16.0562
09.16.0575
09.16.0585
09.16.0595
09.16.0525
26
LOWER (10/Pkg.)
09.16.0614
09.16.0616
09.16.0618
09.16.0620
09.16.0666
09.16.0662
09.16.0675
09.16.0685
09.16.0695
09.16.0625
LOWER (10/Pkg.)
09.23.0612
09.23.0614
09.23.0616
09.23.0618
09.23.0620
09.23.0666
09.23.0662
09.23.0675
09.23.0685
09.23.0695
09.23.0625
BioTru™ NiTi
Archwires
THERMAL
Europa I
SIZE
.014
.016
.018
.020
.016X.016
.016X.022
.017X.025
.018X.025
.019X.025
.021X.025
UPPER (10/Pkg.)
09.16.0314
09.16.0316
09.16.0318
09.16.0320
09.16.0366
09.16.0362
09.16.0375
09.16.0385
09.15.0395
09.16.0325
BioTru™ Copper
BIOTRU™ COPPER 27°
SIZE
.013
.014
.016
.018
.014X.025
.016X.025
.018X.025
UNIVERSAL MEDIUM (10/Pkg.)
09.01.0913
09.01.0914
09.01.0916
09.01.0918
09.01.0942
09.01.0965
09.01.0985
BioTru™ Contour NiTi
CONTOUR NITI 35° DAMON FORMAT
SIZE
.013
.014
.016
.018
.014X.025
.016X.025
.017X.025
.018X.025
.019X.025
UNIVERSAL MEDIUM (10/Pkg.)
51.10.913C
51.10.914C
51.10.916C
51.10.918C
51.10.945C
51.10.965C
51.10.975C
51.10.985C
51.10.995C
27
LOWER (10/Pkg.)
09.16.0414
09.16.0416
09.16.0418
09.16.0420
09.16.0466
09.16.0462
09.16.0475
09.16.0485
09.16.0495
09.16.0425
BioTru™ Retraction
Archwires
DOUBLE KEY (STAINLESS STEEL) (10/PKG.)
ARCH SIZES: 22 mm, 24 mm, 26 mm, 28 mm, 30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm, 42 mm, 44 mm
AVAILABLE IN: .016x.022, .017x.025, .018x.025, .019x.025, .021x.025
KIT w/120
10 OF EACH SIZE
.016x.022
.017x.025
.018x.025
.019x.025
.021x.025
41.99.062
41.99.075
41.99.085
41.99.095
41.99.025
4 DOUBLE KEY (STAINLESS STEEL) (10/PKG.)
ARCH SIZES: 22 mm, 24 mm, 26 mm, 28 mm, 30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm, 42 mm, 44 mm
AVAILABLE IN: .016x.022, .017x.025, .018x.025, .019x.025, .021x.025
KIT w/120
10 OF EACH SIZE
.016x.022
.017x.025
.018x.025
.019x.025
.021x.025
42.99.062
42.99.075
42.99.085
42.99.095
42.99.025
T-LOOP DOUBLE KEY (STAINLESS STEEL OR BETA TITANIUM*) (10/PKG.)
ARCH SIZES: 22 mm, 24 mm, 26 mm, 28 mm, 30 mm, 32 mm, 34 mm, 36 mm, 38 mm, 40 mm, 42 mm, 44 mm
AVAILABLE IN: .016x.022, .017x.025, .019x.025, .021x.025
KIT w/120
10 OF EACH SIZE
Stainless
Beta Titanium
.016x.022
.017x.025
.019x.025
.021x.025
41.99.062
41.99.062
41.99.075
41.99.075
41.99.095
41.99.095
41.99.025
41.99.025
*Compares to TMA, a registered trademark of Ormco Corporation.
28
Archwires
BioTru™ Beta Titanium*
DAMON FORMAT
SIZE
SMALL (10/Pkg.)
MEDIUM (10/Pkg.)
UNIVERSAL (10/Pkg.)
.016x.022
.017x.025
.019x.025
60.10.962P
60.10.975P
60.10.995P
60.10.962M
60.10.975M
60.10.995M
60.10.962
60.10.975
60.10.995
BioTru™ Stainless Steel
Natural
SIZE
.012
.014
.016
.018
.020
.016x.016
.016X.022
.017X.025
.018X.025
.019X.025
.021X.025
UPPER (10/Pkg.)
40.20.112
40.20.114
40.20.116
40.20.118
40.20.120
40.20.166
40.20.162
40.20.175
40.20.185
40.20.195
40.20.125
LOWER (10/Pkg.)
40.20.212
40.20.214
40.20.216
40.20.218
40.20.220
40.20.266
40.20.262
40.20.275
40.20.218
40.20.295
40.20.225
Europa I
SIZE
.012
.014
.016
.018
.020
.016X.016
.016X.022
.017X.025
.018X.025
.019X.025
.021X.025
UPPER (10/Pkg.)
40.10.112E
40.10.114E
40.10.116E
40.10.118E
40.10.120E
40.10.166E
40.10.162E
40.10.175E
40.10.185E
40.10.195E
40.10.125E
LOWER (10/Pkg.)
40.10.212E
40.10.214E
40.10.216E
40.10.218E
40.10.220E
40.10.266E
40.10.262E
40.10.275E
40.10.285E
40.10.295E
40.10.225E
*Compares to TMA, a registered trademark of Ormco Corporation.
29
Great Lakes
BioTru
™
Buccal Tubes
Low profile for maximum
patient comfort
Criss-cross permanent guide
Marks on the facial surface
assist in bonding and
positioning
Color-enhanced ID
Optimal functional
occlusion and case
finishing
Malleable ball hook
enhances patient
comfort - avoids
gingival impingement
Funneled entrance
helps guide the wire
into buccal tube
Torque in base for
easy alignment
BENEFITS
• Advanced design and
manufacturing technologies
ensure maximum strength
for increased clinical performance
and patient comfort.
• All buccal tubes have Direct
Bonding Bases.
APPLICATIONS
• Low profile, compact design
reduces occlusal interference
and gingival impingement for
better hygiene.
• Funneled entrance helps guide
the wire into the buccal tube
• Utilized in posterior teeth (1st and 2nd
Molars) on the vestibular faces
• Buccal tubes are directly bonded to
the tooth surface.
• Allows easier placement of larger
wires due to wider slot entrance.
CHARACTERISTICS
• Malleable ball hooks can be
positioned away from soft tissue
to avoid irritation and potential
food traps
Low Profile Bondable
Non-Convertible Single Tubes MIM Injection Molded
• .080 gauge indented foil mesh
pad increases bonding strength
• Torque: In base
• Four distinct shapes of foil mesh
pads for perfect tooth anatomy
fitting
AVAILABLE
PRESCRIPTIONS
• Roth
• MBT
• Edgewise/Ricketts
.018" and .022" Slots
• MIM in 316L low nickel surgical
stainless steel
Great Lakes’ version of the Damon, Roth, and MBT prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
30
Auxiliaries
Buccal Tubes
MAXILLARY
SINGLE CONVERTIBLE
3.8
.018" R.
20.13.181C
BONDABLE
.018" L.
.022" R.
20.13.182C 20.14.181C
.022" L.
20.14.182C
10°
3.8
20.13.211C
20.13.212C
20.14.212C
TORQ.
OFFSET
mm
0°
0°
3.6
08.03.0101*
08.03.0201*
08.04.0101*
08.04.0201*
0°
8°
3.6
20.43.081*
20.43.082*
20.44.081*
20.44.082*
Prescription
TORQ.
OFFSET
mm
Roth
-10°
8°
MBT
-14°
Prescription
Edgewise /
Ricketts
20.14.211C
SINGLE NON-CONVERTIBLE
-
.018" R.
BONDABLE
.018" L.
.022" R.
.022" L.
Roth
-10°
8°
3.6
08.03.0105*
08.03.0205*
08.04.0105*
08.04.0205*
MBT
-14°
10°
3.6
08.03.0107*
08.03.0207*
08.04.0107*
08.04.0207*
Prescription
TORQ.
OFFSET
mm
MBT
-20°
0°
3.8
.018" R.
20.13.304C
BONDABLE
.018" L.
.022" R.
20.13.303C 20.14.304C
.022" L.
20.14.303C
Roth
-25°
5°
3.8
20.13.454C
20.13.453C
20.14.453C
Prescription
TORQ.
OFFSET
mm
Edgewise /
Ricketts
0°
0°
0°
-20°
MANDIBULAR
SINGLE CONVERTIBLE
20.14.454C
SINGLE NON-CONVERTIBLE
MBT
Roth
.018" R.
BONDABLE
.018" L.
.022" R.
.022" L.
3.6
08.03.0301*
08.03.0401* 08.04.0301*
08.04.0401*
5°
3.6
20.43.054*
20.43.053*
0°
3.6
08.03.0308*
08.03.0408* 08.04.0308*
20.44.054*
20.44.053*
08.04.0408*
-25°
0°
3.6
20.43.404*
20.43.403*
20.44.404*
20.44.403*
-25°
5°
3.6
08.03.0310*
08.03.0410*
08.04.0310*
08.04.0410*
* For bondable tubes, the reference code must end with the option of mesh pad base type: (B) Big Foot. (L) Long. (C) anatomic or (X) Small
BONDABLE BASES FOR NON-CONVERTIBLE TUBES (CONVERTIBLE TUBES ONLY COME IN ANATOMIC)
ANATOMIC
5 mm x 3 mm
LONG
7 mm x 2.8 mm
SMALL
4.3 mm x 3 mm
BIGFOOT
8 mm x 3.5 mm
Great Lakes’ version of the Roth prescriptions. Does not imply endorsement by the doctor. Damon is a registered trademark of Ormco Corporation.
31
Auxiliaries
Ball Hooks
ITEM
ITEM # (10/Pkg.)
Bi-drectional Bracket Hook
Bracket Ball Hook
Bi-drectional Bracket Hook
01.00.0011
01.00.0009
Bracket Ball Hook
Stops
SIZE
DIAMETER
ITEM # (10/Pkg.)
2 mm
0.13 mm
01.00.0002
3 mm
0.13 mm
01.00.0006
NiTi Springs
OPEN
SIZE
ITEM # (3/Pkg.)
.010X.030 - 7"
07.10.2602
.012X.030 - 7"
07.10.2702
.014X.030 - 7"
07.10.2802
.014X.045 - 7"
07.10.3002
DISTALIZATION
SIZE
ROLL LENGTH
ITEM # (10/Pkg.)
.010X.045
38 cm
07.09.3107
.012X.045
38 cm
07.09.2907
CLOSED / RETRACTION
32
SIZE
FORCE
SIZE
ITEM # (10/Pkg.)
.010X.030
Light
6 mm
07.11.4105
.010X.030
Light
9 mm
07.11.4205
.010X.030
Light
12 mm
07.11.3405
.010X.030
Light
15 mm
07.11.3505
.011X.030
Medium
6 mm
07.11.3605
.011X.030
Medium
9 mm
07.11.3705
.011X.030
Medium
12 mm
07.11.3805
.011X.030
Medium
15 mm
07.11.3905
.012X.030
Heavy
6 mm
07.11.4005
.012X.030
Heavy
9 mm
07.11.4305
.012X.030
Heavy
12 mm
07.11.3205
.012X.030
Heavy
15 mm
07.11.3305
Accessories
Ligatures
ELASTIC CHAIN
AVAILABLE IN 1 M OR 4.5 M ROLLS
COLORS
COLORS
MAGENTA
PEARLY BLUE
DESERT BLUE
PINK
BLACK
TURQUOISE
HOT PINK
PEARLY GREEN
TRANSPARENT
METALLIC BLUE
METALLIC RED
LIGHT BLUE
FLUORESCENT ORANGE
FLUORESCENT PINK
FLUORESCENT BLUE
NEON GREEN
DARK GREEN
NAVY BLUE
GREEN
YELLOW
ORANGE
WHITE
METALLIC PURPLE
PURPLE
ROYAL BLUE
RED
METALLIC GRAY
RED RUBY
INTRAORAL ELASTIC
ITEM #
COLOR
FORCE
SIZE (100/Pkg.)
00.90.184
00.90.185
00.90.186
00.90.187
00.90.189
00.90.188
00.90.190
00.90.191
00.90.193
00.90.192
00.90.194
00.90.195
Natural
Natural
Natural
Natural
Natural
Natural
Natural
Natural
Natural
Natural
Natural
Natural
Light
Light
Light
Light
Medium
Medium
Medium
Medium
Heavy
Heavy
Heavy
Heavy
1/8"
1/4"
3/16"
5/16"
1/8"
1/4"
3/16"
5/16"
1/8"
1/4"
3/16"
5/16"
SEPARATORS
ITEM # (1000/Pkg.)
00.90.202
STICK TIES
ITEM #
00.90.135R
00.90.136R
00.90.137R
00.90.139R
00.90.140R
00.90.141R
00.90.144R
00.90.145R
00.90.146R
00.90.147R
00.90.149R
00.90.150R
00.90.152R
00.90.155R
33
COLOR (520/Pkg.)
RED STICK TIE R
METALLIC BLUE STICK TIE R
GRAY STICK TIE R
YELLOW STICK TIE R
BLACKBERRY STICK TIE R
LIGHT GREEN STICK TIE R
NAVY BLUE STICK TIE R
BLACK STICK TIE R
MAGENTA STICK TIE R
PINK STICK TIE R
WHITE STICK TIE R
GREEN STICK TIE R
ORANGE STICK TIE R
TRANSPARENT STICK TIE R
Accessories
Adhesives
Light Bond™ Kit
Intended for use as a light cure bracket and lingual retainer adhesive. Bonds to any
enamel, porcelain, composite, or metal surface when properly conditioned. Temperature
Limitation: Store at room temperature not to exceed 86°F or can be refrigerated 36-46°F.
(Refrigeration will prolong the shelf life of Light Bond™. Allow product to reach room
temperature prior to use.)
Includes: (4) 20 g Push Syringes, 23 g Liquid Etchant, 6 ml Assure® Plus Bonding Resin, Mixing
Pad, Spatulas, and Brushes.
065-042
Light Bond™ Kit Reliance Flow Tain® Composite
Flow Tain® is used for fabricating bonded lingual retainers and bonding brackets. This
flowable light cure material is smooth when cured, reducing wear and enhancing patient
comfort. Tip dispensers provide better control without slumping.
Includes: (1) 1.5 g Syringe and (10) 22 Gauge Tips.
065-040
Reliance Flow Tain® Composite
Reliance Band-Lok™
065-026
Flouride-releasing, two-paste glass ionomer band cement. Better adhesion to enamel
and band surfaces is achieved, reducing washout and preventing loose bands. No
unpleasant aftertaste. Consistent mix viscosity.
Paste A with Fluoride (6 g)
065-026
Paste B (6 g)
065-001
065-001
Reliance Light Bond™ Visible Light Cure Sealant & Bracket Bonding System
Incorporates a smooth tacky paste so that bracket flotation is virtually impossible. Bonds
all plastic, ceramic, sapphire, and metal brackets to enamel and porcelain surfaces.
Includes: (4) 5 g Filled Syringes, (2) 3 cc Light Cure Sealant Resins, (1) 24 g Etching Agent, and
Mixing Pads.
Reliance Light Bond™ Visible Light
Cure Sealant & Bracket Bonding System
065-032
Reliance First & Final
The first prophy pumice specially formulated for orthodontic use. Conveniently packaged
in cups for individual patient use and pre-mixed - no messy mixing with water. Pumices
better and rinses cleaner for better bond strength. No flavoring, flourides, or oils to inhibit
and weaken the bond. Can also be used for polishing the enamel after debonding.
Reliance First & Final (200/pkg.)
065-041
Reliance Enhance® Adhesion Booster
Increases the adhesion of any bonding agent to flourosed, hypo-calcified or deciduous
enamel to acrylic, composite, or metal surfaces. Ideal for any enamel surface where
maximum adhesion is required and for enamel close to the gingiva, where minor surface
moisture may reduce bond strength.
Part A (3 cc)
065-034
Part B (3 cc)
065-035
065-034
065-035
34
Accessories
Reliance Therma-Cure® Heat curable lab adhesive for metal, ceramic, and plastic brackets.
065-033
Reliance Therma-Cure® (5 g)
Reliance Maximum Cure® Sealant
065-021
065-022
Flouride-releasing, chemical-curing sealant system. No curing light required. The whole
labial tooth surface can be sealed. Increases adhesive strength to enamel. Requires
refrigeration.
Part A with Fluoride (7 g)
065-021
Part B (7 g)
065-022
Reliance Excel® with Fluoride
Excel®’s three minute set time is ideal for bonded Herbsts*, bonded RPEs and indirect
bonding. Its thin viscosity will flow easily onto bracket base, pad, or acrylic appliance.
Includes: 12 g Catalyst Paste A, 12 g Base Paste B, 9 g Etching Agent, Spatulas, Mixing Brushes,
Pallet Mixing Dish, and Pad.
Reliance Excel® with Fluoride
065-037
Paste A with Fluoride (12 g)
065-038
Paste B (12 g)
065-039
065-038
065-039
Reliance Phase II®
065-004
065-019
065-018
Sealant and bonding system for direct bonding. Sealant reduces decalcification. Strong
enough to bond molar attachments, but is easily removed in one piece.
065-004
Liquid Etching Agent (9 g)
1-½" Dispoable Brushes (50/pkg.)
065-018
Spatulas (5/pkg.)
065-019
Mixing Pads (3/pkg.)
065-020
065-020
Bite Ramps
Mini Mold Starter Kit
Mini Mold Tips precisely cast a light-cured resin appliance in seconds. It does the job
quickly and easily. Just fill the mold, place on tooth, and cure. Select from 10 different
treatment aids.
Kit includes: (3) Habit Control, (3) Anterior Bite Ramp -5 mm, (3) Anterior Bite Ramp-3 mm,
(3) Posterior Molar Pad, (3) Wire Bonder (small), (3) Wire Bonder (large), (3) Button Bonder,
(3) Bracket Bonder, (3) Tube Bonder, (3) Cuspid Bite Ramp, and (2) Bonder Handles.
Mini Mold Starter Kit 195-030
Bite Ramp Bonder
Forms a bite opening ramp on the lingual of the upper incisors: Used to adjust the
occlusion as needed. Available in 5 mm and 3 mm.
Includes: (8) Mini Mold Ramp Tips and (1) Bonder Handle.
195-031
3 mm (8/pkg.) 5 mm (8/pkg.) 195-032
*Herbst is a registered trademark of Dentaurum, Inc.
35
Notes
36
Great Lakes
Bracket Catalog
2016
Exceptional Quality.
200 Cooper Avenue
PO Box 5111
Tonawanda, NY 14151-5111
1.800.828.7626 (U.S. & Canada)
716.871.1161 (Worldwide)
Email: [email protected]
www.GreatLakesBrackets.com
SMPP580Rev031716
Manufactured by Aditek® Orthodontics
Outstanding Value.

Similar documents

mu04feb16-Amplaid A137

mu04feb16-Amplaid A137 Peltor noise enclosures ADC noise enclosures Patient handswitch Power cable Instruction Manual BC vibrator, B71 Single insert phone Operator monitor phones Operator microphone Goose-neck operator m...

More information

Hustler® Raptor® Parts Manual

Hustler® Raptor® Parts Manual This Parts Manual provides a complete parts listing for the unit. Use this manual when ordering parts. Illustrations used were current at the time of printing, but subsequent production changes may...

More information