exhibitors guide - Espace Exposant SILMO 2016
Transcription
exhibitors guide - Espace Exposant SILMO 2016
EXHIBITORSGUIDE > Interactive browsing,click onthetitles toaccessthe information youneed. USER GUIDE USEFUL INFORMATION FITTINGS REGULATIONS &FORMALITIES SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE EXHIBITORSGUIDE > BACK TO THE HOME PAGE USER GUIDE TWOTOOLS TOHELPYOU GETREADYFOR THESHOW • THISISANINTERACTIVEEXHIBITORGUIDE Withthisdocument,youcan: • Easilyaccessalltheinformationneeded togetyouupandrunning. • ReachyourExhibitorArea • Completetheformsfromthisdocument, directlyonyourcomputer. • THEEXHIBITORAREA(forbarestands) In this store, you can order all of the technical services you need untilTuesday20September2016. Pleasenote:fromTuesday20September2016,technicalservicesmustbeordered directlyon-siteinExhibitorsdeskslocatedhalls6. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE EXHIBITORSGUIDE > BACK TO THE HOME PAGE • Access/traffic&parking • Hangings&overheadpowersupply,trussesandlight USEFUL INFORMATION • Events/StandActivities • Architecture&Decoration • Complementaryinsurance • CateringfortheExhibitors • Accessbadges • Usefulcontacts • ExhibitortimetablesAssembly/Opening/Dismantling • Exhibitionopeninghours/Exhibitorsdesks • Healthandsafety • Cleaning/Vacatingthestand • Meeting/Conferencerooms • Hallmonitoring/Standsecurity SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION ACCESS/TRAFFIC &PARKING ACCESS TO THE PARIS-NORD VILLEPINTE EXHIBITION CENTRE • • • • • • London:2h35(Eurostar) Lille:50mn(TGV) Rennes:2h45(TGV) LyonPartDieu:1h55(TGV) Montpellier:3h50(TGV) Marseille:3h30(TGV) SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE 1/6 BACKTOTHECONTENTS USEFULINFORMATION ACCESS/TRAFFIC &PARKING CARS AND PEDESTRIAN ACCESS SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE 2/6 BACKTOTHECONTENTS USEFULINFORMATION ACCESS/TRAFFIC &PARKING 3/6 TWO INTERNATIONAL AIPORTS TO GET TO SILMO Roissy Charles de Gaulle airport TheParcdesExpositionsislocated5mins.awayfromRoissyCharlesdeGaulleairport. TaketheRERB–direction:Robinson-SaintRémy-Les-Chevreuseandgetoffatthestop: ParcdesExpositions. Orly airport TaketheOrly-Val(automatedmetro)toAntony,thentaketheRERB(direction:Roissy-Charles deGaulle).GetoffatParcdesExpositions. YOUR TICKETS AT THE BEST PRICE WITH AIR FRANCE AND KLM GLOBAL MEETINGS Visitthewebsite:www.aifranceklm-globalmeetings.com • Event:SILMO 2016 • EventID:27962AF • Validfortransportfrom18/09/2016 to 01/10/2016 • Eventlocation:ParcdesExpositionsdeParisNordVillepinte,France AttractivediscountsonawiderangeofairfaresonallAirFranceandKLMflightsworldwide**. (Until47%ofreductionontheinternalFrenchflights(includingCorsica). Usethewebsiteofthiseventorvisitwww.airfranceklm-globalmeetings.comto: • Accessthepreferentialfaresgrantedforthisevent*, • Makeyourbooking, • Issueyourelectronicticket*, • Selectyourseat**. IfyoubuyyourticketviaAIRFRANCE&KLMGlobalMeetingswebsite,yourelectronicticket willcarryaspecialmentionwhichjustifiestheapplicationofthepreferentialfares.Shouldyou prefer to process your reservations and ticket-purchase directly with an Air France and KLM salesoutlet,youmustkeepthiscurrentdocumentwhichservestojustifytheapplicationofthe preferentialairfares Keep the document to justify the special fares with you as you may be asked for it at any point of your journey. Frequent flyer / loyalty programs of Air France and KLM partner airlines are credited with "miles"whenAirFranceorKLMflightsareused. *Subjecttoconditions/**Notavailableincertaincountries SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION ACCESS/TRAFFIC &PARKING 4/6 TRAFFIC IN THE EXHIBITION CENTER TherearestrictrulesfordrivingthroughtheExhibitionCentregrounds.Youmustrespectthem andnotifyallyourinstallationworkers,transportersandsuppliers. Do not forget to tell them your stand and hall numbers. • Obeythehighwaycode • Limityourspeedto20kmh(12mph) • Nostoppingandnoparkingintrafficlanes, • Lightdutyvehicleswon’tbeallowedintotheHalls, • Lorrieswillbeallowedaccessunderspecificconditionsandsubjecttotrafficcontrol. • Deliveriesareauthorizedfrom7:30amto8:30am. Any vehicle which contravenes these rules will be removed without notice, at the expense and risk of its owner or the party responsible. CAUTION:We thank you to plan your deliveries because of circulation restrictions in France during weekends. Formoreinformation:www.bison-fute.equipement.gouv.fr DURING BUILD-UP • • • • • • • • • Duringinstallationanddismantling,exhibitor’scarparksarefree. No cars will be allowed inside the Halls. Lorrie’s trafficwillbecontrolled. Emptypackingmaterialsmustberemoved immediately and stored by the Exhibitors or their freight carriers. Storage space on stands must not be used to keep packing materialsoranyothergoods thatcouldconstituteafirehazard. SettingupmustbecompletedbythetimetheSafety Commissionmakesitsinspection. Thepersoninchargeofyourstandmustbepresentatthistime.Dateandtimewillbe announcedlater. No motor vehicles will be allowed into the halls on Thursday 22nd September(unless specialpermissionisgrantedbytheorganizer). ToentertheexhibitionHallsduringinstallationanddismantling,all personnel must wear personal safety equipment,inparticularsafetyshoes.Otherwise,accesstotheexhibition willberefused. Forsafetyreasons,workintheHallsisforbiddenoutsidethespecifiedhoursonWorking hours. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION ACCESS/TRAFFIC &PARKING 5/6 PARKING > During assembly It is free to park on Exhibition Centre grounds as long as the regulations regarding parking times and areas are respected. Exhibitors car parks will no longer be free as of midnight on Thursday22ndSeptember. LorryaccessissubjecttospecialconditionsdependingontrafficlevelsaroundtheHalls. No motor vehicles may enter the Halls on Thursday 22nd September (except where special permissionhasbeengrantedbytheorganiser). • • Avoidorderingdeliveriesforthedaybeforetheexhibition. Assoonasyouhaveemptiedyourvehicles,movethemon. > On dismantling evening Only trolleys, platform trolleys and hand pallet truck may be used when the show is closed. MotorvehiclesmayentertheHallstwohoursafterpublicclosingtime,aslongasthespaceis insuchaconditionastopermitthis. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION ACCESS/TRAFFIC &PARKING 6/6 > During opening times Deliveriesareauthorisedfrom7:30amto8:30amoncevehicleshavebeenapprovedforentry intotheExhibitionCentregroundsandgivenatemporarydeliverypermit. NoparkingorvehiclestorageofanykindisauthorisedwithintheExhibitionCentregrounds. Parking is not permitted on traffic movement corridors or safety perimeters once the exhibitionhasbeenopenedtothepublic. Please note:asofFriday 23rd September at 9:00 am,allvehiclesparkedbesidetheHallsmust havebeenmovedtotheauthorisedcarsparks,failingwhichthevehiclemayberemovedand impounded. RESERVING A PARKING SPACE Parkingsubscriptionscanbetakenoutforafee.TheycanbereservedviayourExhibitorArea. Whileset-upanddismantlingperiods,youcanbuycarparkingspacesattheExhibitorsDesks, hall6. TheExhibitors’carparksareopenfrom7:00amto11:00pmeverydaythroughouttheevent. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS AMÉNAGEMENTDESTANDS HANGING&OVERHEADPOWER SUPPLY,TRUSSES&LIGHTS Hangings and overhead power supplies Trusses and lights SILMO is available to support you along with its partner VERSANT EVENEMENT , which offers a total service package for setting up your presentation space. Its varied stock of displaystructureswillmeetallyourrequirements.Fromthebiggestofspacestothemost elaborate, VERSANT can help you at every stage of your project, from advice to engineeringplans,yourchoiceofstructures,lightingandmore. Contact VERSANT EVENEMENT : Tel.:+33(0)148633251 E-mail:[email protected] Website:www.versantevenement.com SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION EVENTS/STANDSACTIVITIES TheSILMOhassetupguidelinestoguaranteethattheeventrunssmoothlyandvisitorsenjoy theirvisittothemaximum. Exhibitors are given free reign as to how their stands are run, so long as the following provisionsareadheredtoandtheexhibitortimetablesarerespected. PROHIBITED SERVICES • • • • • Thedistributionorplacingofleafletsintheexhibitionaisles,attheentrance,onthe esplanadeorclosetothestation, Promotionintheaisles(withrobots,hostesses,sandwichboards,etc.), Offeringtastingsontheedgesoftheaislesorintheaislesthemselves.Theseare permittedwithinthestands, Musicalpromotion, Videowallsmustbesetbackaminimumof2metersfromtheedgesoftheaisle. EventsarrangedwithouttheauthorisationofOrganizerareprohibitedattheexhibition. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION ARCHITECTURE&DECORATION FIND OUT MORE VIA YOUR EXHIBITOR AREA “PRACTICAL INFO” • • Theshow'sArchitecture&Decorationrules Specialregulations The architecture and decoration rules for the SILMO incorporate standards and norms for standlayoutdisplay,establishedtoensuretheexhibitionisrolledoutsmoothlyandiseasyto navigate.ThesenormsandstandardsalsoincludetheSecurity&Firerulesapplicabletoshows, fairsandexhibitions. TheSILMOisgovernedbyspecificregulationsinaccordancewithitsownspecial characteristics.Allproposalsforbarestands,reusedstandsorfittedstandsfittedoutbythe SILMOtowhichnewdecorativeitemsaretobeadded,mustbesubmittedfor approval by 26th August 2016 at the latest. DECOPLUS Élisabeth TOUGARD E-mail:[email protected] EACH FLOOR PLAN MUST INCLUDE • • Abird'seyeviewofthestand,includinginformationpertainingtoscales,sidesand positioningofset-backspace(adjacentareasandaisles), Across-sectionfloorplanincludinginformationpertainingtoscales,sidesandheightsof theplannedvolumes. VERY IMPORTANT Anyproposalsthatdonotcomplywiththesetrulesshallberejectedand,inparticular,any standassembledwithouttheSILMO’sagreementmaybedismantledattheexhibitor's expense. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION COMPLEMENTARYINSURANCE FIND OUT MORE VIA YOUR EXHIBITOR AREA Tofindoutwhatrulesandregulationsgovernyourinsuranceduringtheshow,checkthe "Practical information/Regulations"sectioninyourExhibitorAreaandordercomplementary insurancein"My Store" section. COMPLEMENTARY INSURANCE AGAINST DAMAGE TO PROPERTY Exhibitors may take out complementary insurance provided by the SILMO to cover their propertyifthelatter'svalueexceedstheamountcoveredbytheinsurancepolicytakenoutas partoftheregistrationapplication. This cover takes effect from the day before the show opens to the public (at 7:00 pm on 22/09/2016)totheeveningonwhichtheshowclosestothepublic(6:30pmon26/09/2016). Thepremiumwillbeequalto0.27%ofthevalueoftheinsuredgoods. PLASMA SCREEN & LCD INSURANCE ExhibitorshavetheoptionoftakingoutspecificinsurancefromtheSILMOforplasmascreens andLCDfixedorsecurelywiredtothestand'sframe. This cover takes effect from the day on which the show opens to the public (at 8:30 am on 23/09/2016)totheeveningonwhichtheshowclosestothepublic(6:30pmon26/09/2016). Thepremiumwillbeequalto4%ofthevalueoftheequipment,withaminimumof250euros perinsuredscreen. THEFT INSURANCE Theft insurance enables you to insure the full value of your stand (excluding food products, beverages, etc.) against the risk of theft, with an excess of € 300 per incident. For the extra declaredvalue,theinsurancepremiumincludingtaxandcostswillbecalculatedatarateof 0.63%. LOSSES No losses may be accepted as valid without having been declared to the show's exhibitor reception within 24h. All damage claims must state the date, the circumstances and the approximateamountofdamagesandmustbeaccompaniedbytheoriginalpolicereportinthe event of theft. Cases of theft that are not covered by the SILMO but are insured by the exhibitor'sownpolicymustbedocumentedinacomplaintformsentwithintherequiredtimeframetotheVillepintePoliceStationortheexhibitor'shometown(ifinMetropolitanFrance): VILLEPINTE POLICE STATION 1/3,rueJeanFourgeaud–93420VILLEPINTE-FRANCE Tél.:+33(0)149634610 SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION ACCESSBADGES VERY IMPORTANT: COMPULSORY PASS-WEARING • • • InordertobegrantedaccesstotheexhibitionHalls,all individuals must have been issued an SILMOaccessbadge,whichmustbecustomizedonyouExhibitorAreaandbe wornduringtheassembly,openinganddismantlingperiods. Identity checkswilltakeplacearoundtheHalls. Security equipmentsandthewearingofsafetyfootweariscompulsoryduringset-upand dismantlingperiods.FailuretocomplyshallresultinaccesstotheHallsbeingdenied. EXHIBITOR BADGE TheexhibitorbadgegrantsaccesstotheExhibitionCentreduringtheassembly,openingand dismantlingperiodsinaccordancewiththetimetablesthatfeatureontheexhibitortimetable. (SeeExhibitorTimetabledocument–Clickhere). • ExhibitorscandeclareandpersonalisetheirbadgesintheExhibitorArea. • Thenumberofbadgesprovidediscalculatedautomaticallyaccordingtothesurfaceareaof thestand,tothevalueoffourbadgesfor12,00sq.m. • BadgesmustbeprintedfromyourExhibitorArea. • Requestsforadditionalbadges,anorderisavailableinyourExhibitorArea. ASSEMBLY/DISMANTLING BADGES RegisteryourserviceprovidersinyourExhibitorAreasothattheycangeneratetheirassembly anddismantlingBadge. The assembly/dismantling badge grants access to the Exhibition Centre during the assembly anddismantlingperiodsinaccordancewiththetimetablesthatfeatureonthebadge. Badges are not valid during the exhibition opening period which runs from 23 to 26 September 2016. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION USEFULCONTACTS 1/2 FOR FURTHER INFORMATION, CONTACT HOTLINE: +33 (0)1.40.68.23.00 Monday to Friday, 9.00 am – 6.00 pm Accommodations Architecture & decoration (layout control) B-NETWORK DECOPLUS LauraPACCHIONI Tel:+33(0)158162010 E-mail: [email protected] Website:http://silmo.b-network.com/ 13, rue de Fourqueux 78100 St-Germain-Laye - France Tél. : +33 (0)1 47 63 94 84 - Élisabeth TOUGARD E-mail:[email protected] Catering on stand AREAS a subsidiary of ELIOR Group Tel:+33(0)148633200 E-mail:[email protected] Website:www.elior-parcexpos.com Catering on stand HORETO Tel:+33(0)148633345 E-mail:[email protected]:www.horeto.com Catering on stand (External suppliers declaration) VIPARIS MyriamMOTTIN Tel.:+33(0)1406814 46 E-mail:[email protected] Complementary insurance Copyrights SIACI SACEM 18,ruedeCourcelles 75008Paris-France Tel:+33(0)144202981 Fax:+33(0)144202980 E-mail:[email protected] DélégationRégionaledeStGratien 16,avenueGabrielPéri-BP103 95210STGratien–France Tel:+33(0)176767480 Website:www.sacem.fr/ French customs INFO DOUANES SERVICE FromFrance:0811204444(0.06€/mn) Fromabroad:+33(0)172407850 Website:www.douane.gouv.fr/ Hanging & hoverhead power supply Trusses & lights VERSANT EVENEMENTS Tél.:+33(0)148633251 E-mail:[email protected] Website:www.versantevenement.com: GO TO YOUR EXHIBITORS AREA TO SEE THE COMPLETE LIST OF SERVICE PROVIDERS. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION USEFULCONTACTS 2/2 USEFUL CONTACTS (CONT.) Hospital HPS coordinator Fire Prevention Fireproofing On-site access for people with disabilities Parc des Expositions Personalized stand Police station VAT refound HOPITAL INTERCOMMUNAL ROBERT BALLANGER SOCIÉTÉ D.O.T. BdRobertBallanger 93602Aulnay-sous-Bois-France Tel.:15or+33(0)148964444 81,ruedeParis 92100Boulogne-France Tel:+33(0)146051785 Fax:+33(0)146057648 E-mail:[email protected] CABINET SÉCURITÉ & INCENDIE AFS CONSEILS AlainFRANCIONI 76,rueBaudin 93130Noisy-le-Sec-France Tel:+33(0)141550721 Port:+33(0)670619511 E-mail:[email protected] GROUPEMENT NON FEU 37-39ruedeNeuilly–BP121 92582Clichy-France Tel:+33(0)147563080 Fax:+33(0)147370620 Website:www.securofeu.com/ E-mail:[email protected] POINT INFO VIPARIS LIVRAISON DE MARCHANDISES DECORAMA COMMISSARIAT DE POLICE TEVEA INTERNATIONAL +33(0)614169384 SILMO VIPARIS-ParcdesExpositions Yourcompanyname,Hall/Stand number 93420Villepinte-France 11,rueMauriceGunsbourg 94200Ivry/Seine-France Contact:IngridTHORAVAL Tel:+33(0)145152400 E-mail: [email protected] 1/3,ruedeFourgeaud 93420Villepinte-France Tel.:+33(0)149634610 29-31rueSaintAugustin 75002Paris6-France Tel:+33(0)142249696 Fax.:+33(0)142248923 E-mail:[email protected] Website:www.tevea-international.com GO TO YOUR EXHIBITORS AREA TO SEE THE COMPLETE LIST OF SERVICE PROVIDERS. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION EXHIBITORSTIMETABLES ASSEMBLY/OPENING/DISMANTLING WORKING HOURS, SET UP, DISMANTLING, POWER SUPPLY Exhibitors schedule Power supply Tuesday 20 September 7:00am–8:00pm - Wednesday 21 September 7:30am–8:30pm 7:30am–8:30pm Thursday 22 September 7:30am–midnight 7:30am–midnight Friday 23 September 7:30am–7:00pm 7:30am–7:00pm Saturday 24 September 8:00am–7:00pm 8:30am–7:00pm Sunday 25 September 8:00am–7:00pm 8:30am–7:00pm Monday 26 September 8:00am–6:30pm 8:30am–6:30pm BareStands ComexposiumNaço Stand(2) Monday 26 September 6:30pm–midnight 6:30pm–7:00pm Barestands Tuesday 27 September 7:00am–midnight - Barestands Wednesday 28 September 7:00am–2:00pm - Dates Set Up Barestands BareStands ComexposiumNaço Stand(1) Dismantling Opening (1) (2) nd ComexposiumNaçostanddeliverywillbemadeonThursday22 September2016from8:00am. Storageandfurnitureshouldbeemptiedofcontentson26Septemberbetween6:30pmandmidnight Advice: To get power supply outside this hours, don’t forget to order 24 hours power supply. EXHIBITORS TIMETABLE DURING THE EXHIBITION • • ThehallsareaccessibletoExhibitorswithabadgefrom8:00am(7:30amonthefirstday oftheexhibition). Deliveriesduringtheexhibitionopeningperiodaretobemadebetween7:30amand8:30 am,failingwhichthevehiclemayberemoved. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION EXHIBITIONOPENINGHOURS EXHIBITORSRECEPTIONDESKS EXHIBITION OPENING HOURS Dates rd Friday 23 September 2016 th Saturday 24 September 2016 th Sunday 25 September 2016 th Monday 26 September 2016 Visitors opening hours 9:00 am – 6:30 pm 9:00 am – 6:30 pm 9:00 am – 6:30 pm 9:00 am – 6:30 pm THE EXHIBITORS RECEPTION DESK ON SITE • ExhibitorsReceptionDeskswillbelocatedinthehall 6. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION HEALTHANDSAFETY FIND OUT MORE VIA YOUR EXHIBITOR AREA • • ToreadtheHealth&Safetyregulations,checkthe'RegulationsandFormalities'section FillinyourHealth&Safetycertificatedirectlyonlineinthe'MyForms'section HEALTH AND SAFETY GUIDELINES IHSPP: Individual Health & Safety Protection Plan. ToenjoyaccesstotheexhibitionHalls,allindividualsmustbefittedwithanaccesspassforthe SILMO(Exhibitorpass,Assembly/Dismantlingpass)andmustwearsafetyequipment,including inparticularsafetyfootwear. FailuretodososhallresultinaccesstotheExhibitionHallsbeingrefused. IMPORTANT TheHealth&Safetyguidelinesmustbesharedwithallofyoursub-contractorsavailableinyou ExhibitorArea. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION CATERING FOREXHIBITORS SET AND PROVISIONAL CATERING TheSILMOmakesrestaurantsavailabletoyouandyourclientsintheexhibitionHalls. Barsarealsoavailable. A list of the restaurants and bars open during the assembly and dismantling periods will be availableontheshow'swebsite. RECEPTIONS AND COCKTAIL RECEPTIONS Theconcessionaireisatyourservicetoorganisereceptions:meals,buffets,cocktails. All caterers are authorised to provide their services in the exhibition centre upon notifying VIPARISandfinalisingatemporaryinterventioncontract. For further details, contact: Exhibition Centre Concessionaire AREAS a subsidiary of ELIOR Group Salesdepartment Tel:+33(0)148633200 E-mail:[email protected] Website:www.eliance-parcexpos.com HORETO TRAITEUR Salesdepartment Tel:+33(0)148633345 E-mail:[email protected] Website:www.horeto.com External caterer declaration VIPARIS Concessiondepartment MyriamMottin Tel:+33(0)140681446 E-mail:[email protected] SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION CLEANING VACATINGTHESTAND 1/2 HALLS & STANDS CLEANING • • • • Halls,standsandaisleswillbecleanedeverymorningbeforeopeningoreveryevening aftertheshowhasbeenclosedtovisitorsandExhibitors. Dailycleaningisincludedinyourstandhire(excludingglasscabinets,partitionsand washing)andthefinalpreparationcleaningofpartitionsandglasscabinetsthedaybefore opening(onlyforfittedstand). Thoroughcleaningofyourstandandglasscabinetsisessentialtodisplayyourproductsto theirbestadvantagetocustomers.TheSILMOguaranteesthequalityofthisservice. Cleaningisprohibitedduringtheshowopeninghours,asisplacingwasteandrubbishin theaislesinthemorningsafter9:00am. Please note: Ifyou have booked a bare stand,dailycleaningofyourstandisincluded(withoutfinal preparationcleaningofpartitionsandglasscabinetsthedaybeforeopening). Ifyouhave booked a fitted stand,dailycleaningofyourstandisincluded(withfinal preparationcleaningofpartitionsandglasscabinetsthedaybeforeopening). SERVICES INCLUDED IN THE DAILY CLEANING OF YOUR STAND Daily cleaning with vacuuming includes: vacuuming the floor including on upper levels, emptying of ashtrays and waste paper bins, wiping furniture and furnishing objects within reach,collectingandremovingproductionwaste. Excluded from this service are: The cleaning of partitions and signs, cleaning exhibited machinesandmaterials,cleaningglassanddisplaycabinets,theprovisionofskips,theremoval of carpets and glue at the end of the exhibition (unless your carpet was ordered from the SILMO). FIND OUT MORE VIA YOUR EXHIBITOR AREA Toordercleaningskips,check"MyStore"section. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION CLEANING VACATINGTHESTAND 2/2 DURING ASSEMBLY AND DISMANTLING • • • • ShowcleaningserviceprovidersareonhandattheExhibitordesksareaslocatedhalls6to provideyouwithanestimateforsupplyingaskipforyourmaterialsandwaste/rubbish. Allstands,materials,merchandiseandwasteofanykind(adhesives,carpeting,etc.)must beremoved. Theexhibitorundertakestoremoveandprocesstheirwasteincompliancewiththe regulationsinforce. Oncethedismantlingdeadlinehaspassed,theSILMOmaytakeanymeasuresitdeems usefultoremovethematerialsandwastethatremainonthestandsiteattheexhibitor's expense,riskandperil,aswellasmeasuresusefultodestroyingstructuresanddécorof anykindwhichtheexhibitormayhavefailedtodismantle. Tip:Ifyoucallupontheservicesofadecorator/designerforyourstand,makesurethatthe quoteyouagreeuponincludeswasteremoval. OPTIONAL SERVICES Forbarestands,the final preparation cleaning the day before openingistoorderinyour exhibitorspace. Thisserviceincludestheremovalofemptypackagingandwaste,thecleaningofpartitions, glasscabinetsandprovisionofbinliners. Duringbuild-upanddismantlingperiods,weofferthelastcarriagearrangement(1.00m3)and dumpsters(30.00m3)todisposeofyourwaste. Orderyoursupplementaryservicesin ‘My Store’ section. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION MEETING/CONFERENCEROOMS CONFERENCE AND MEETING ROOMS RENTAL Conference/meetingroomsareavailabletohireduringthedurationoftheshow. Ifyou'dliketoseeourroomhireoffers,pleasecontact: SandrineQUESNOT E-mail:[email protected] Tel.:+33(0)176771528 Thanktospecify: • Dayandtimeofdesiredrental • Numberofpeopleexpected • Settingthedesiredroom(meeting,"U",...) • Typeofeventyouwanttoorganize(pressconference,productpresentation,cocktails...) • Specialneeds(audiovisual,cateringservice,...) SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS USEFULINFORMATION HALLMONITORING &STANDSECURITY FIND OUT MORE VIA YOUR EXHIBITOR AREA Toorderasecurityservice,checkthe"Practical info”section,list of suppliers. HALL MONITORING Generalsurveillanceoftheshowistheresponsibilityoftheorganiserandiscarriedoutinthe verybestconditions,yetthisisanobligationofmeansandnotofresults. The show's security company is aware of an increase in thefts and will ensure increased surveillanceinthecommonareas. Car parks are not monitored, objects of value inside vehicles must not be left out to ensure theydonotattractinterest. STAND SURVEILLANCE Exhibitors who choose to use special surveillance for their stands are asked to inform the organiserofthisfactbyprovidingalistofthepeoplewhowillbeinterveningonthestandas wellasthenameandcontactdetailsofthechosensurveillancecompany. Exhibitors are responsible for their own stands and must take all necessary precautions to ensure their equipment is protected and removed in the evening upon closing if no surveillancehasbeenputinplace. ImportedgoodsmustbeclearedbytheCustomsServicebeforebeingplacedontheExhibitor's stand. Please note:Standstockroomsarenotsecurepremises. THEFT PREVENTION Duetoanincreaseintheftnotedduringtheassembly,openinganddismantlingperiods,some basicrulesmustbeappliedbytheexhibitor: • Donotleaveyourpersonalbelongingsout(wallets,handbags,bags,etc.), • Donotleavemobilephonesunattended, • Intheevening,tidyawayanyvaluableitems(computers,laptops,tablets)inalockable unitortakethemhomewithyou, • Duringtheassemblyanddismantlingperiods,onepersonmustcontinuouslybepresentat thestand. This person serves as your only guarantee against theft. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE EXHIBITORSGUIDE > BACK TO THE HOME PAGE • Baresurface • Prepstepsforyourfittedstand Naço FITTINGS • ComexposiumNaçostandbyMarceloJoulia SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FITTINGS BARESURFACE 1/3 YOU HAVE RESERVED A BARE SURFACE • Minimumsurfacearea>12.00s.qm. Equipment included in your surface area hire includes: • Demarcationofyoursurfaceareaonthefloor, • Awoodenpartition(2.50mhigh)coveredwithbeigebrushedcottonfabric(exceptfor islandstands), • Astandsign, • Dailystandcleaningincluding:binsemptied,floorvacuumed,countersandfurniture wipeddown, • Oneparkingpass(Onrequestviatheformoftheonlineshopbeforethe1stSeptember). STAND LAYOUT PREP STEPS, BARE SURFACE > • • 1st step: stand allocation TheSILMOwillsendyouafloorplanforyoutoconsiderbeforeacceptingyoursite offer. Onceapproved,thisfloorplanwillallowyoutoplanforyourstandlayoutwiththe decorator/designerofyourchoice. 2nd step: order any technical services (electric and internet connections, phone lines, parking facilities, etc.) FindallavailableservicesinyourExhibitorArea,under“MyStore”. > > 3rd step: checking your plan Your stand's decoration and design plan must be submitted for approval by the show's Architecture&Decorationdepartmentbefore 26th August 2016 to: DECOPLUS Élisabeth TOUGARD E-mail:[email protected] For information on the details to be supplied, check the Architecture & Decoration Regulations (in the regulations chapter of this guide, or on your Exhibitor Area, section “Practicalinfo/Rules”). > 4th step: your stand at the fair Pleasechecktheassemblyschedule.Clickhere. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FITTINGS BARESURFACE 2/3 MANDATORY: HEALTH & SAFETY NOTICE (HSP:HealthandSafetyPlan). • • • • TheHealthandSafetyNoticeshouldbecompletedbyExhibitors,andcanbefoundin yourExhibitorAreaunder“MyForms”. TheNoticemustbedistributedtoallsuppliersandsub-contractors. YoumustbewearingaSILMOaccessbadge(Exhibitor/ServiceProviderBadge)aswell aspropersafetyequipment(safetyboots,helmet,etc.)inordertoenterthehall. Failuretomeettheseconditionswillresultinyoubeingrefusedentrytothehall. TheHSPmustbevalidatedbeforereceivingauthorizationtoenterthehall. ADDITIONAL SERVICES SILMO provides a full range of services to improve the organization of your stand and to optimize your presence at the fair. Details can be found in your Exhibitor Area, under “My Store”. HANGINGS AND OVERHEAD POWER SUPPLIES, TRUSSES AND LIGHTS SILMOisavailabletosupportyoualongwithitspartnerVERSANT EVENEMENT,whichoffersa total service package for setting up your presentation space. Its varied stock of display structureswillmeetallyourrequirements.Fromthebiggestofspacestothemostelaborate, VERSANTcanhelpyouateverystageofyourproject,fromadvicetoengineeringplans,your choiceofstructures,lightingandmore. Contact VERSANT EVENEMENT: Tel.:+33(0)148633251 E-mail:[email protected] Website:www.versantevenement.com SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FITTINGS BARESURFACE 3/3 ADDITIONAL SERVICES TO BE ORDERED BEFORE THE STAND IS FITTED: • • • • • • Additionalfittings(carpet,technicalfloor,storageroom,partitions,lighting,etc.) Furniture, Refrigeratedfurniture, Floraldecoration, Video/Audiomaterial, Coffeemachine,fridge. Besuretoorderinadvanceasstockislimitedoncefittinghasbegun. CLEANING/WASTE REMOVAL During fitting and dismantling: SILMOisavailableandmorethanhappytoprovideyouwithanestimatefordisposingofyour equipmentandwastes.WeareatyourdisposalattheExhibitorsDesks. Toorderclean-upskips,seeyourExhibitorArea,“MyStore”. OTHERS ADDITIONAL SERVICES Stand security, hostesses, caterer… in your Exhibitor Area, section “practical info, list of suppliers”. IMPORTANT All stands, equipment, merchandise and waste (stickers, carpet, etc.) absolutely must be removedbeforetheendofdismantling. Ifyoudonotmakeuseoftheservicesprovidedbytheorganizer,thenyouareresponsiblefor removinganddisposingofallproducts,inlinewithcurrentlegislation. Oncethedismantlingdeadlineshavepassed,theOrganizermay,atthecostandliabilityofthe Exhibitor,takeanymeasuresdeemedusefultodisposeoftheremainingequipmentandwaste onthepitch,aswellasthedestructionofstructuresanddecorationofanykindthathavenot beendismantled. Recommendation Ifyououtsourcedecoratorservices,besurethatyourquoteincludes“fitting”,“dismantling”, andwasteremoval,andaddthemiftheyarenotfeaturedonthequote. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FITTINGS PREPSTEPSFORYOUR COMMEXPOSIUMNAÇOSTAND STAND LAYOUT PREP STEPS FOR YOUR FITTED STAND > Step 1: ordering your stand SILMOwillsendyouaplanforyourstandbypostorbyemailforyourapproval. > 2nd step: equipment approval included in your stand ASILMOFittedStandadvisorwillcontactyoubyemailforyourapprovalaboutyourchoiceof colour scheme, the positioning of your storage and sign, your choice of furniture, and the variousservicesincludedwithyourstand. > 3rd step: ordering add-on technical facilities and services The SILMO fitted stand advisor will confirm all additional services required to organize your stand,withacatalogueofoptions. Additional services to be ordered before stand is fitted: • Additionalfurnishings,refrigeration,flowers, • Audio-visualequipment,officeequipment,etc. Besuretoorderinadvanceasstockislimitedoncefittinghasbegun. Ifyoubookadditionalservices,theymustbeorderedassoonaspossibleandcertainlybefore thefair,inordertoguaranteethebestpossiblevarietyofranges,colourschemes,sizes,and deliverydates. Onsite,orderedserviceswillbeprovidedwhilestockslast. Forsecuritystandproviders,hostesses,caterers,etc.consultthe"listofsuppliers":Clickhere. > 4th step: Health and Safety TheHealthandSafetyNoticemustbecompletedonyourExhibitorAreaunder“MyForms”. > 5th step: delivery of your stand on Thursday 22nd September 2016 *Forallstandswithfreshproducts,remembertoorderapermanent24helectricitysupply,not includedasstandard. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FITTINGS COMEXPOSIUMNAÇOSTAND 1/2 ANEXCLUSIVESTANDBYMARCELLOJOULIA YOU HAVE BOOKED COMEXPOSIUM NAÇO STAND • • Surfacearea:from12,00sq.m.to36,00sq.m.maximum Standoccupancystartdate:ThursdaySeptember22nd–8.00am Non-bindingpicture Carpet:tiles2colorsavailable(Bordeauxred), Non-bindingpicture Carpet:tiles2colorsavailable(Bordeauxred), SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FITTINGS COMEXPOSIUMNACOSTAND ANEXCLUSIVESTANDBYMARCELLOJOULIA 2/2 Fittings includes: • Carpet:tiles2colorsavailable(greyorBordeauxred), • Whitepartitions(10cmthick/2.70mhigh),partitionsheadsinanodizedaluminum. 1mrecessfromtheaisles, • 1sq.mstorageareaforstandsfrom12to24sq.m/2sq.mforstandsfrom24to36 sq.m, • DigitalSign(tablet)withnameandstandnumberdisplayedonthepartitionhead, • Backlitsignage, • Lighting:walllightsingreymetal+LED(3for12sq.m), • Powersupply:3kwfusedpowersupply(daytimeonly)locatedinthestorageroom, 1triplesocketincluded,1socketoneachstandside, • Dailycleaning(includingafinalpreparationcleaningthedaybeforetheopening). Example including furniture: Exampleincludingwhitefurniture(tobeorderin“MyStore”) SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE EXHIBITORSGUIDE > BACK TO THE HOME PAGE REGULATIONS &FORMALITIES REGULATIONS • Disabledaccessattheshow • Architecture&decorationrules • Fire&panicriskspreventionregulations READOTHERREGULATIONSINYOUREXHIBITORAREA • Standardtermsandconditionsofexhibitionfloor spacelettingandstandequipment • Generalrulesandregulationsgoverningexhibitions • Tenantrisk/propertydamageinsurancepolicy • Generaltermsandconditionsofsalefor communicationtools FORMALITIES • Customs • Exhibitorsafetyinstructions • Usingforeignserviceproviders • RefoundofFrenchVAT(TVA) SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS DISABLEDACCESS ATTHESHOW PREAMBULE ACCESS TO STANDS ON UPPER FLOORS The order of 1st August 2006 lays out the conditions for applicationofarticlesR111-19toR111-9-3andR111-19-6 oftheBuildingandHabitationCodeconcerningtheaccessof handicapped people in establishments for public use and installations open to the public during their construction or creation. Generally the Halls, exhibition Halls, and installations in exhibition centres meet the requirements of this order: accessibility,toilets,carparking,etc. Furthermore, regarding installations open to the public during their creation, it is necessary to allow handicapped people access to stands, conference or meeting rooms, grandstands,orcateringareas. In the shows organised by COMEXPOSIUM, the Security Manager is responsible for ordering any measures required andcarryingoutinspectionsatshows. Thegeneralandspecificmeasuresapplicabletoinstallations createdattradeshowsandexhibitionsaregivenhereafter: ACCESS TO SINGLE-LEVEL STANDS 1)Whenthenumbersofgeneralpublichostedontheupper floor does not exceed 50 people, the services on the upper floormustbeequivalenttothegroundfloor. • If this is not the case, and/or if the numbers of the public hosted on the upper floor exceeds 50 people, the upper floor will be accessible via a lift in compliance with the standardNFEN81-70.Thisinstallationmustbeverifiedby an organisation approved by the Ministry of the Interior beforeitsuse. 2)Respecttheprovisionsofarticle7.1oftheaforementioned order,regardingstaircases. Widthof1.20mbetweenhandrails. • Two continuous hand rails, extended at the top and the bottom of the staircase, horizontally, returning on a partitionorextendedbythelengthofthetreadofastep. • Amaximumstepheightof16cmandaminimumtreadof 28cm–stepedgesincontrastingcolours • 0.5mwidthtactilefootstripatthetopofthestairs. • Respectthestaircasedesigngoodpractice:60cm<2H+T <64cm(H=stepheight,T=streptread). • Hand rails and safety rails must respect the standards NFP01-12andNFP01-013. FITTING OF ROOMS OR AREAS RECEIVING SEATED MEMBERS OF THE PUBLIC (CONFERENCES, STANDS, GRANDSTAND, ETC.) Eachstand,areaopentothepublic,fittedwithafloorhigher than2cmmustbeaccessibletoPeopleofReducedMobility (PRM). One or several ramps, of a minimum width of 90 cm, will facilitate this access. Slopes will respect the following percentages: • 4%slopewithoutlimittothelengthofthepassageway • 5%slopeonalengthoflessthan10m • 8%slopeonalengthoflessthan2m • 10%slopeonalengthoflessthan0.5m Clearance of a radius of 1.5 m will be left free for manoeuvringateachendoftheramp. PATHWAYS • Widthof1.4mminimum. Areasreservedforwheelchairuserswillbeprovided. These areas must be located outside of alleyways and corridors and close to exits. The number will be calculated enabling two places for the first 50 seats and one place per additional50seats. WELCOME AND INFORMATION DESKS Welcomeandinformationdesksmustbeaccessibletopeople usingawheelchair. • Height80cm,agapof30cmdepthonaheightof70cm, enablingspaceforknees. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS ARCHITECTURE &DECORATIONRULES IMPORTANT The SILMO Architectural Regulations cover the stand fittingout and construction rules which have been set out to guarantee the proper operation of the exhibition as well as optimumvisitcomfort. No agreement made between exhibitors will be authorized, only the Organizer are entitled to grant dispensation upon submissionofawrittenrequest In order to avoid disputes, it is mandatory to submit the th standlayoutplanforapprovalbyAugust 26 , 2016. Thestandlayoutplanmustnecessarilyincludethefollowing elements: • Planviewincludingscaleanddimensions; • Elevationviewincludingscale,dimensions,andheights ofprojectedvolumes. AnyprojectthatwillnotcomplywiththeRegulationswillbe rejected, and any stand that would be erected without the approval of the following architectural firm would be dismantledattheexhibitor'sexpense. DECOPLUS Mme Élisabeth TOUGARD 13, rue de Fourqueux 78100 SAINT-GERMAIN-EN-LAYE E-mail:[email protected] Your space must be restored to its original condition. An outgoing inventory of fixtures will be requested; it will be issued by the exhibition's technical support office on completionofthestanddismantling. All waste materials (e.g. carpeting, adhesives) must be removed. Otherwise COMEXPOSIUM will charge you a packagedependingonthesurfaceofyourboothis: • Boothlessthanabout99,00sq.m=1000,00€, • Boothbetween100,00sq.mand199,00sq.m=2000,00€, • Boothfrom200,00sq.m=3000,00€ Anydamagereportedonstanddismantlingwillbechargedto theexhibitorwhoisliableforthedamage. The exhibitor is personally responsible for his suppliers, i.e. decorators,installers,contractors. 1- HALL FLOOR, PILLARS AND WALLS Itisstrictlyforbiddentodrill,screw,nailorembedthewalls, claddingpanels,pillarsandfloorsofthehalls,inparticularto anchorexhibitedmachines. Afixedpriceof€300excl.VATperholewillbechargedtothe exhibitor in case of non-compliance with these instructions. Furthermore,itisforbiddentopaintormarkthewalls,pillars andfloorofthehalls. 1/2 2- STAND INSTALLATION AND DISPLAY OF EXHIBITS Exhibitsondisplaymustnotdisturbnordamageneighbouring stands. Equipment and machinery must not project beyond thestandboundaries. 3- SOUND PRESENTATIONS Exhibitors who wish to use sound equipment on their stands mustcomplywiththefollowingrules: Thesoundpowerreflectedbythedecorationorpresentation items shall not exceed 80 dB(A) – when measured within a 2.50metreareasurroundingthestand.Theruleslaiddownfor the use of sound equipment on stands are intended to minimizeinconveniencetoneighbouringstands. Moreover, for playing music or organizing musical presentations on your stand, you must pay fees before the exhibitionopeningtotheFrenchmusicrightsbody:-- SACEM 16,avenueGabrielPéri 95210SAINTGRATIEN-FRANCE Tel.:+33(0)139341910 E-mail:[email protected] Please comply with the above sound level without exception and even for a short time. Continuous and severe inspection will be carried out to ensure that these rules are strictly observed. The organizer reserves the right to take all appropriate measures to stop any sound presentation performed in violationoftheaboverules. 4- ELECTRICAL INSTALLATIONS ON STANDS Forobvioussafetyreasons,itisstrictlyforbiddentousetheprivate installations of the exhibition centre (e.g. hall ducts, water ducts) forlayingelectricalcablestothestands. 5- STAND CONSTRUCTION Maximum height for stand decoration: 4.00m Structures,decorationitemsandsigns(standsign,advertising panels and balloons) must not be higher than 4.00 m above thebuildingfloor. Nosetbackisrequiredfromadjoiningstandsandfromaisles. ATTENTION: Office backsides, decoration items and panels facingneighbouringstands(from2.40mto4.00mhigh)must be smooth, plain, painted in neutral colours, and must not includeanysignsoradvertisements. Electricalcablesmustnotbevisible. Allowedfloorloading:35tonnesor13tonnesperaxle. Overload:5tonnes/sq.m. Resistancetopuncture:6.5tonnesmaxiper10sq.cm. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS ARCHITECTURE &DECORATIONRULES Stand enclosing: Entirelyenclosedstandsareprohibited. Anopeningofatleastonethirdofthestandperimetermust beprovided. Stand on your project we will find through openings in compliancewithfiresafetyregulations(seeregulationsforfire safetyofexhibitor'sguide). 6- DOUBLE-DECK STANDS Double-deckconstructionsinhallsareauthorizedsubjectto theexpressapprovaloftheOrganizer,andprovidedtheir floorsurfaceisatleast250,00sq.mandtheyarelocated alonghallperipherywalls. 7- SIGN Anoffercombiningsignsandkakemonosisproposedto exhibitorswithastandsurfaceareaof120,00sq.mandabove. Thesesignsandkakemonosaremanufacturedandinstalledby theOrganizer. Theywillbeplacedat6,00mabovethebuildingfloor. 8- LIGHTING BRIDGES Lightingbridgeswillbeauthorizedataheightof4.50mabove thebuildingfloor. Theyshallincludenosignsanddonotneedtobesetback fromadjacentstandsandaisles. Gobosshallbeconfinedtoyourstandsurfacearea,light sweepingshallnotbeauthorizedoutsideyourstandlimits. Flashinglightsandbeaconsareprohibited. COMEXPOSIUM accompanies you with his VERSANT partner Ofthecatcherinthehighlight,VERSANTrealizeaglobal serviceforthedirectionofyourspace. Hisstockofscenicstructurevariedallowstoanswerallyour demands. Ofthesmallestsurfaceinthemostelaborate,VERSANT accompaniesyouinallthestagesofyourproject:advice, studiestechniques,choiceofthestructures,highlight… To contactVERSANT EVENEMENT: E-mail:[email protected] Tel.:+33(0)148633251 Website:www.versantevenement.com 2/2 10- HANGING FROM THE FRAMEWORK Hanging operations from the hall framework must be carried out exclusively by the technical services of the exhibition centre. Requests must be submitted directly to the SILMO platform(http://services.silmoparis.com). In all cases, suspended elements must comply with the exhibition'sdecorationrules. Theslingingpointshallbecontrolledatamaximumheightof 4.80m. 11- LEAFLETS AND MUSIC Unlessacommercialagreementhasbeenspecificallyreached, it is strictly forbidden to distribute leaflets, handouts, etc. outsidethestands,includingintheareasaroundthehalls(i.e. check-ingallery,carparks,frontsquare). 12- MACHINERY OPERATION AND EQUIPMENT IN All machines and equipment shown in operation during the exhibition must be declared to the exhibition Organizer, otherwisetheywillhavetoceaseoperation.Allpresentations anddemonstrationsshallbecarriedoutundertheexhibitor's fullresponsibility.Aprotectedareashallbeprovidedtoensure thatthepubliciskeptataminimumdistanceof1.00mfrom operating machines. This distance may be increased depending on the exhibit's features. Only machines and equipment approved by the Safety Commission as complying with the regulations will be allowed to be exhibited in operation 13- ACCESSIBILITY FOR PERSONS WITH REDUCED MOBILITY Accordingtotheapplicableregulations,whenthestand floorboardheightisgreaterthan2.00cm,arampisrequired toprovideaccessforpeoplewithreducedmobility.Access rampsarenotpermittedtoprojectintoaisles. Accessrampsshallbeatleast0.90mwidewithslopes between2%and5%. 9- PILLAR COVERING Maximum height 4.00 m from the floor. Coveringmaterialscanrestonthepillar,butmustbekept awayor,atleast,isolatedwithasoftmaterial(e.g.felt,soft board)placedatcontactpoints. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS 1. OVERVIEW Safetyrulesregardingrisksoffireandpanicinestablishments opentothepublichavebeenestablishedbytheOrderdated th June 25 , 1980 (general provisions). The Order dated th November 18 , 1987 sets forth the specific provisions applicabletoexhibitionHalls. Thetextbelowisexcerptedfromsaidregulationsinorderto facilitateunderstanding. TheSafetyBoardisquitesevereregardingstandconstruction (stability, construction and decoration materials, electrical installations, etc.). The decisions made during Safety Board inspections, the day before or the morning the event opens must be immediately implemented. Stand installation must becompletedforSafetyBoardinspections. The exhibitor (or his representative) must be present at the standandbepreparedtoprovideflammabilityreportsforall materials used. Non-compliance with this rule may lead to theremovalofsuchmaterialsoraprohibitiononopeningthe standtothepublic. All large projects (> 40 m²) must be submitted to the trade show’s Safety Supervisor for approval. Drawings and technicalinformationmustbesubmittedtotheorganizerat leastonemonthbeforethetradeshowopens. During the assembly period, the Safety Supervisor shall monitor application of the safety rules indicated hereinafter. Moreover, all information regarding fire safety may be obtained by calling: AFS Conseils et Sécurité M.AlainFRANCIONI 76,rueBaudin–93130NOISYLESEC Tél.:+33(0)670619511-Fax:+33(0)141550721 E-mail:[email protected] FIRE SAFETY RATINGS FOR MATERIALS (Decree of 30 June 1983): In France, there are 5 categories of fire ratings (given here with their rough equivalents): M0 (A2), M1 (A2-B), M2 (C), M3 (D) and M4 (E except Ed2). M0 is an incombustible material. 2. STANDS FITTING-OUT 2.1 – Stand framework and partitions – Large furniture All materials classed M0, M1, M2, and M3(1) shall be permitted for stand framework and partition construction and for building large furnishing (crates, counters, display stands,separationscreens,etc.) Conventional classification for wooden materials (Order th datedJune30 ,1983) Thefollowingshallbedeemedtohavethecharacteristicsof M3classmaterials: • solidnon-resinouswoodwhosethicknessisgreaterthanor equalto14mm, • solid resinous wood whose thickness is greater than or equalto18mm, 1/8 • wood-derivative panels (plywood, lath, fibreboard, particleboard) whose thickness is greater than or equal to 18mm. N.B.: It is absolutely prohibited to place any facilities above the alleyways (structure or fascia band, bridge, etc.) 2.2 - Surfacing Materials 2.2.1 - Wall Surfacing Wallsurfacing(naturaltextilesorplastics)mustbecomposed ofM0,M1,orM2(1)classmaterials.Theymaybestretched or attached with clips. Various very thin (1 mm max.) surfacing (fabric, paper, plastic films) may be used bonded directly on M0, M1, M2, or M3 material support surfaces. However,embossedorreliefpapermustbebondeddirectly to M0 materials only. Exhibited materials may be presented inthestandswithoutrequiredfire-reactiontesting. Nevertheless, if said materials are used for decorating partitions or fake ceilings, and if they represent more than 20% of the total surface of said elements, the provisions contained in the preceding paragraphs shall apply to them. However,saidprovisionsshallnotapplytotradeshowsand stands specifically for interior decoration in which textiles andwallsurfacingarepresented. (1)Ormadesobyfireproofing 2.2.2 - Curtains - Wall Hangings - Sheer Curtains Curtains, wall hangings, and sheer curtains may be freehangingiftheyareclassM0,M1,orM2.Theyare,however, prohibitedonstandentranceandexitdoors,butauthorized oncabindoors. 2.2.3 - Paints and Varnishes Paints and varnishes are strictly prohibited if they are deemedflammable(e.g.nitrocelluloseorglycerophtalic) 2.2.4 - Floor, Podium, Stage, and Tier Surfacing FloorsurfacingmustbecomposedofM4classmaterialsand solidly attached. Surfacing, whether horizontal or not, of podiums,stages,andtiershigherthan0.3mandtotalsurface area greater than 20 s.qm must be constructed of M3 class materials.Iftheirtotalsurfaceareaislessthanorequalto20 m²saidsurfacingmaybeconstructedinM4classmaterials. N.B.: for M3 or M4 class carpets on wood, factor in the attachment method. Fire reaction testing data must include the statement: “Valid for stretched laying on M3 class supports.” 2.3 - Decorative Elements 2.3.1 - Free-Hanging Elements Decorative elements or free-hanging decor panels (advertising panels with a surface area greater than 0.5 m², garlands, light decorative items, etc.) must be composed of M0orM1classmaterials. Theuseofsignsandadvertisingcontainingwhitelettersona green background is strictly prohibited, as said colours are exclusivelyreservedforindicatingexitsandemergencyexits. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS 2.3.2 - Floral Decorations Floraldecorationsandsyntheticmaterialsmustbelimited.If not, said decorations must be produced using M2 class materials. The present provisions shall not apply to trade showsandstandsspecifictofloralactivities N.B.: For natural plants, give preference to the use of peat humuswhichmustbekeptdampatalltimes. 2.3.3 - Furniture There are no requirements for common furniture (chairs, tables, desks, etc.). However, crates, counters, shelving, etc. mustbecomposedofM3(1)materials. 2.4 - Canopies - Ceilings - Suspended Ceilings Standswithceilings,suspendedceilings,orfullcanopiesmust have a covered surface area less than 300 m². Should the coveredsurfaceareabegreaterthan50m²,theappropriate fire suppression systems manned continuously by at least one safety agent must be provided during times when the publicispresent. 2.4.1- Canopies Canopiesshallbeauthorizedunderthefollowingconditions: • in establishments protected by an automatic water based fire suppression system (2), the canopies must be composedofM0,M1,orM2(1)materials, • in establishments not protected by an automatic water basedfiresuppressionsystem,theymustbecomposedof M0orM1classmaterials. In addition, they must have an effective hanging system preventing them from falling and be supported by a system ofcrosswireswithamaximummeshsizeof1m².Inallcases, ceiling and suspended ceiling suspension and attachment mustuseM0classmaterials.Wheninsulationisplacedinthe ceilingorsuspendedceilingplenum,itmustbecomposedof M1classmaterials. 2.4.2 - Ceilings and Suspended Ceilings CeilingsandsuspendedceilingsmustbecomposedofM0or M1classmaterials. Nevertheless, 25% of the total surface area of ceilings and suspended ceilings may be composed of M2 class materials. Lighting fixtures and accessories shall be included in said percentage. Moreover, should the ceiling and suspended ceiling component elements be perforated or netted, they may be composed of M2 class materials where the solid surface is less than 50% of the total surface area of such ceilingsandsuspendedceilings. 2.5 – Handicapped Person Access Installing a floor pan on the ground whose thickness is greater than 7 mm requires it to be fitted around its entire perimeter with a slope whose depth shall be equal to twice itsheight(i.e.:fora2cmthickfloorpan,theslopeshallhave a 4 cm depth). This point shall constitute dispense for the creationofanambulantdisabledpersons’entranceforfloor pansupto4cmthick.Beyondthisthickness,inaddition,all floors where the public may go must include an integrated ambulantdisabledpersonsramp,whichmaynot 2/8 impingeuponthetravelcircuits.Itmustbe0.9mwidewitha slopebetween2%and5%. 2.6 – Fireproofing Proof of fire reaction classification for the materials used in the exhibition Halls must be provided upon request to the Safety Supervisor in the form of labels, reports, and certificates. Surfacingandmaterialsfulfillingthesafetyrequirementsare availableforpurchasefromspecializedmerchantswhomust providecertificatescorrespondingtomaterialclassification. Toobtainalistofsuchmerchants,contact: GROUPEMENT NON FEU 37-39,ruedeNeuilly BP249,92113Clichy(Tel.:+33(0)147563081) (2)ThisisthecaseofHalls5and6attheParcd’ExpositonsdeParisNordVillepinte N.B.: Fireproofing may only be applied to wooden panels or natural fabrics or those with a significant proportion of natural fibres. It is not possible for synthetic fabrics or plastics. VERY IMPORTANT: Original foreign reports may not be used. Only reports from approved French laboratories shall be accepted (Euroclass classification table at the end of the present rules) 2.7 – Exterior Stands and Marquees, Tents, and Structures AnybuildingorconstructionslocatedoutsidetheHallsmust have a case file indicating site location, dimensioned drawings of the construction with surface area, number of levels,etc. This file must be submitted for approval to the Security Supervisoratleasttwomonthsbeforetheevent. In some cases, smoke evacuation, verification of assemblysolidity-stability,andaverificationofelectricalfacilitiesbyan approvedbodymayberequested. Marquee, tent, structure definition: A closed, itinerant establishmentwithaflexiblecover,forvarioususes. This type of establishment must have an attestation of conformity delivered by a Marquee, Tent, and Structure Verification Office. Contact the Security Supervisor ((M. Alain Francioni, Cabinet AFS conseils & sécurité)) for information regarding the steps to take. 3 – ELECTRICITY 3.1 - Electrical Facilities The electrical facilities for each stand must be integrally protected against surcharges and ground faults. All metal grounds must be interconnected and connected to the stand’selectricalswitchboardground.Electricalconnections must be made inside connection housings. Electricity cut-off systemsmustbecontinuouslyaccessibletostandstaff. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS 3.2 - Electrical Equipment 3.2.1 - Electric Wiring Electric wiring must be insulated for a minimum of 500 V, which prohibits the use of H-03-VHH (scindex) wiring. Use only wiring for which each conductor has its own protective sheath, with all conductors housed in a single protective sheath. 3.2.2 – Conductors Theuseofconductorswithacross-sectionlessthan1.5mm² isprohibited. 3.2.3 - Electric Devices Class 0 (3) electric devices must be protected by nominal differentialcurrentsystemsofatleast30MA. Class I (3) electric devices must be connected to the protectiveconductorintheirsupplyline. ForClassII(3)electricdevices,thosebearingthesymbolare recommended. 3.2.4 - Multi-sockets Only fixed-based multi-sockets or adapters are allowed (mouldedmulti-sockets) 3.2.5 - Halogen bulbs (EN 60598 standard) Lightingfixturescontaininghalogenbulbsmustbe: • placedataheightofatleast2.25m, • kept away from flammable materials (at least 0.5 m from woodandotherdecorativematerials), • solidlyattached, • fitted with safety screens (glass or fine mesh) providing protectionagainsttheeffectsofexplodingblubs. 3.2.6 - High-Voltage Lighted Signs High-voltagelightedsignswithinreachofthepublicorstand staff must be protected, in particular the electrodes, by a screenofM3classmaterialorbetter.Thecut-offswitchmust beindicatedandtransformersplacedinaspotthatdoesnot pose a danger to people. Their presence may be indicated withasign“Danger,HighVoltage.” (3)asdefinedinstandardNFC20-030 4 - CLOSED STANDS - ROOMS SETUP IN THE HALLS 4.1 - Closed Stands Some Exhibitors may prefer to be isolated in closed stands. Such stands must comply with decoration rules on page 23 Article 5 and must have direct exits to travel ways. Their numberandsizeshallbebasedonstandsurfacearea,i.e.: • Lessthan20m²:one0.9mexit • from20to50m²:2exits,one0.9m,theother0.6m • from51to100m²:eithertwo0.9mexitsor2exits,one1.4 m,theother0.6m • from101to200m²:eithertwoexits,one1.4m,theother 0.9m,orthree0.9mexits Exits must be evenly distributed (1 every 6 m) and on oppositessidesifpossible.Eachofthemmustbeindicated 3/8 with an “Exit” sign in clearly visible white letters on a green background.Ifthestandisclosedwithdoors,theymustopen outwards,withnolockingsystem,andwithoutswinginginto traffic. 4.2 - Rooms Setup in the Halls Independently of surfaces reserved for exhibition, meeting rooms, restaurants, movie theatres, or presentation rooms withstagesortiers,etc.maybesetup. Platformsandtiersforstandingmusthavearesistanceof600 kilos per m². Platforms and tiers with seats must have a resistanceof400kilosperm². Stairsaccessingtiersmusthaveaheightofatleast0.1mand at most 0.2 m with a going of at least 0.2 m. In this case flightsofstairsarelimitedto10andnosealignmentmustnot exceed45°. As each case is specific, a detailed drawing must be submitted to the Safety Supervisor who shall define the measurestobeapplied. 5 – RAISED LEVELS 5.1 - General Remarks In accordance with standard NF P 06-001, raised level facilitiesmustbesufficientlysolidtoresistweightsof: • forlevelsoflessthan50m²surfacearea:250kilosperm², • forlevelsof50m²andover:350kilosperm². Undernocircumstancesmayraisedlevelsbecovered. N.B.: The method for calculating weights or floor resistance certification must be submitted to the trade show Safety Supervisor during the assembly period. Inaddition,acertificatefromanapprovedorganizationmust certifystandstability. Inaddition,anapprovedorganizationmustverifythestability ofallraisedlevels. Piercing resistance must not be greater than that permitted in the relevant site. Each stand may only have one raised level. Its surface area must be less than 300 m². Each stand must be fitted with fire suppression systems, i.e.: a water sprayextinguisher,placedatthebottomofeachstairwayand a CO2 extinguisher located near the electrical switchboard. Should the raised level be greater than 50 m², the appropriate supplemental fire suppression means must be manned by at least one safety agent at all times when the publicispresent. 5.2 – Entrances and Exits Raised levels must be served by evenly distributed stairs, whosenumberandwidthshallbebasedonthesurfacearea ofsaidlevels,i.e.: • upto19m²:one0.9mstairway, • from20to50m²:2stairways:one0.9m,theother0.6m, • from 51 to 100 m²: either two 0.9 stairways, or two stairwaysone1.4mandtheother0.6m, • from 101 to 200 m²: 2 stairways, one 1.4 m, the other 0.9m, • from201to300m²:two1.4mstairways. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS Onlystairwaysseparatedbyatleast5metresshallbetaken into account. Exits must be indicated with an “Exit” sign in clearlyvisiblewhitelettersonagreenbackground. 5.3 – Straight Stairs Straightstairsforpubliccirculationmustbeconstructedsuch thatthestepscomplywithprofessionalstandardsandflights havenomorethan25steps.Insofaraspossible,flightsmust be in opposite directions. Step height must be between at least13cmand17cmatmost;widthmustbeatleast28cm and36cmatmost.Stepheightandwidthmustberelatedas follows: 0.6 m < 2 H + G < 0.64 m. Said heights and widths must be regular in the same flight, although this is not required for the first step. Landings must be of the same width as the stairs; for fights in the same direction, landing length must be greater than one metre. Stairways whose widthisatleastonepassageunitwidemusthaveahandrail (passage unit = 0.9 m) Those whose width is two passage unitsorgreatermusthaveahandrailoneachside. 5.4 – Spiral Stairs Normal or supplementary spiral stairs must have a continuouscurve,withoutlandingsotherthanatfloors.Step going and height in the stride line, 0.6 m from the core or central gap, must comply with professional standards as indicatedintheprecedingArticle. Moreover,stepexteriorgoingmustbelessthan0.42m. For stairs with a single passage unit, the handrail must be locatedontheouteredge. 5.5 - Stairs with Straight and Spiral Sections In so far as a stairway complies, in its various straight and spiral sections, with the professional standards defined in paragraphs 5.3 and 5.4 hereinabove, said stairway shall be deemed in compliance with regulations and may be used in establishmentsopentothepublic. 5.6 - Guardrails and Stairway Ramps InaccordancewithstandardsNFP01-012andNFP01-013, guardrailsmustresistthrustof100kilosperlinearmetre. Glass panels used as protection must be reinforced or ply glass.Socalled“securit”glassisprohibited. 4/8 6 - LIQUEFIED GASES 6.1 - General Remarks Bottlesofgas,butaneorpropane,shallbealloweduptoone 13 kilo bottle at most for every 10 m² of stand with a maximum of six per stand. The following measures must be taken: There must be at least 5 metres of space between two bottles, unless they are separated by a rigid, noncombustible,1cmthickscreen. No bottle, empty or full, must remain within the exhibition hallifitisnotconnectedtoaworkingline. Bottles must be connected to the device by a standardcompliantflexiblehose. Suchhosesmust: • bereplacedattheirexpirationdate, • be appropriate in connector diameter and fitted with clampingcollars, • notexceed2metresinlength, • be inspectable for their entire length and move freely withoutclamping, • not be reachable by burner flames or by combustion products. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS 6.2 - Device Supply If,exceptionally,abottleistosupplyseveraldevices,tubing must be made of metal (copper or steel). Using solder for connectionsisprohibited. Bottlesmustalwaysbeplaceduprightandthecut-offvalve must remain accessible in all circumstances. All closed-in areas where they are stored must include, on the top and bottom,airventsplacedsoasnottobeblockedbyawall, furniture,oraneighbouringdevice. 6.3 - Installing Cooking Equipment In addition to the abovementioned rules, the following measuresmustbetaken: • The floor (or table) supporting the cooking equipment must be composed of non-combustible material or surfacedwithM0materials. • Cooking equipment must be kept at an appropriate distancefromanycombustiblematerialandbeinstalled soastopreventanyfiredanger. • Ifsuchdevicesarelocatednearapartition,M0surfacing mustbeprovideduptoaheightofonemetrebesidethe device. • Hood vents must be installed above devices producing emanationsorcondensation. • Electricitymetresmustbeatleastonemetrefromwater faucets. Each facility must: - have safety instructions (steps to take in case of fire, numbersforemergencyservices...) -befittedwithoneormoreextinguishers. 7 - OPERATING EQUIPMENT - INTERNAL COMBUSTION ENGINES Every machine presented in operation during the trade show must be declared beforehand, at least one month before the event opens. Only installations that have been declaredmaybeauthorized. Allequipmentmustbecorrectlystabilizedtoavoidrisksof overturning. All protective measures must be fully completedwhentheSafetyBoardpassesforinspection.A person in a position of authority must be present at the standatthistime. No machine may be started or presented operational without qualified personnel present at the stand. All presentations and demonstrations shall be conducted undertheExhibitor’ssoleresponsibility. The electrical power supply shall be suspended, at the relevantexhibitor’sexpense,toanystandwheremachines inoperation presentadangertothepublicandforwhichnomeasures havebeentakentoeliminatethem. 7.1 - Equipment Presented in Operation at a Permanent Station Equipment presented in operation at a permanent station must include appropriate permanent screens or casings, 5/8 preventingthepublicfromaccessingdangerousparts,orbe placed such that the dangerous parts are kept away from thepublic,andattheleast,atadistanceofonemetrefrom trafficcircuits. 7.2 - Equipment Presented in Movement Where equipment is presented in movement, a protected areamustbesetasidesothatthepublicmaynotapproach closer than one meter - said distance may be increased given the characteristics of the equipment presented. Theseprovisionsshallbevalidforallstands,includingthose intheopenair. 7.3 - Equipment with Hydraulic Cylinders If equipment with hydraulic cylinders is exposed in stationary extended position, hydraulic safeties must be supplemented by a mechanical system preventing any unexpectedretraction. 7.4 - Internal Combustion Engines Approval for the use of internal combustion engines must berequestedbeforehandatleast30daysbeforetheevent opens.Suchrequest,onplainpaper(tobeattachedtothe declarationforthemachineordeviceinoperationincluded in the appendix), must specify the type and daily quantity of fuel used and be accompanied by the device’s descriptiveleaflet,andadrawingofthedevice’sinstallation onthestand. No device of this type may be started if the authorization requestwasnotsubmittedontime. WARNING: in any case, combustion gases must be evacuated outside the Halls. 8 - FLAMMABLE LIQUIDS 8.1 - General Remarks The use of flammable liquids shall be limited to the followingquantitiesperstand: • 10litresofcategory2flammableliquidsforevery10m² ofstand,withamaximumof80litres, • 5 litres of category 1 flammable liquids. The use of particularly flammable liquids (carbon disulphide, ethylene oxide, etc.) is prohibited. The following measuresmustbetaken: • placeareceptacleunderthetanksorcontainerscapable ofholdingalltheliquid, • refillthedeviceoutsidethepresenceofthepublic, placetheappropriateextinguishersnearby. 8.2 - Exhibiting Automobiles inside the Halls Exhibitingautomobilesorothervehiclesshallbepermitted within the Halls if they have a direct relationship to the exhibition. Installing “stand” semi-trailers or similar is prohibited. The gas tanks for motors presented stopped must be empty or fitted with locked caps. Accumulator battery terminals must be protected so as to be inaccessible. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS 8.3 - Presenting Flammable Products All containers for flammable liquids presented on the stands (paint or varnish cans, bottles, aerosol cans, etc.) mustbeemptyexceptforafewsamplesinlimitedquantity fordemonstrations. 8.4 – Prohibited Materials, Products, Gases Air, nitrogen, and carbon dioxide gas bottles shall be permittedwithoutrestriction. 8.4.1 – The following shall be prohibited in the exhibition Halls (pursuant to Article T45 of the safety regulations) distributingsamplesorproductscontainingflammablegas; • balloonsinflatedwithflammableortoxicgas; • celluloiditems; • thepresenceofpyrotechnicsorexplosives; • thepresenceofethyleneoxide,carbondisulphide,ethyl ether,oracetone. 8.4.2 – The use of acetylene, oxygen, hydrogen, or a gas presenting the same risks is prohibited, unless a specific waiver is granted by the appropriate administrative authority (Prefecture, Safety Board). ContacttheSafetySupervisor AFS Conseils et Sécurité M.AlainFRANCIONI 76,rueBaudin–93130NOISYLESEC Tél.:+33(0)670619511-Fax:+33(0)141550721 E-mail:[email protected] at least one month before the start of the event for the requiredregulatoryadministrativeprocedure. WARNING: storage of empty of full bottles shall not be tolerated within the Halls. 8.5 – Smoke Production Approval for the use of smoke machines to create fog or lightingeffectsmustberequestedfromtheadministrative authority (Prefecture, Safety Board) at least one month beforethestartoftheevent.ContacttheSafetySupervisor for information regarding the required administrative procedures regarding this request. Such request, on plain paper(tobeattachedtothedeclarationforthemachineor deviceinoperationincludedintheappendix),mustspecify the type and daily quantity of gas used, and be accompanied by the device’s descriptive leaflet and a drawingofthedevice’sinstallationonthestand.Nodevice ofthistypemaybestartediftheauthorizationrequestwas notsubmittedontime. 9 - RADIOACTIVE SUBSTANCES - X-RAYS 9.1 - Radioactive Substances Authorization to present radioactive substances on exhibit standsmayonlybegrantedfordemonstratingdevicesand wheresubstanceradioactivityislessthan: 6/8 • 37 kilobecquerels (1 microcurie) for those composed of GroupI(4)radioelements, • 370 kilobecquerels (10 microcuries) for those composed ofGroupII(4)radioelements, • 3,700 kilobecquerels (100 microcuries) for those composedofGroupIII(4)radioelements. • Waivers may be granted for the use of substances with higheractivitysubjecttothefollowingmeasures: • radioactivesubstancesmustbeeffectivelyprotected, • their presence must be indicated using the ionisation radiationschematicsdefinedinstandardNFM60-101,as wellastheirtypeandradioactivity, • their removal by the public must be made materially impossibleeitherbyattachmenttoadevicerequiringthe useofatooltoremoveorbydistance, • theymustbeunderconstantsurveillancebyoneormore Exhibitors designated by name. When such surveillance ends, even in the absence of the public, the radioactive substances must be stored in a fireproof container, bearingveryclearlytheconventionalsymbolforionizing radiation, • theequivalentdoserate,atallpointsinthestand,must remain under 7.5 micro-sieverts per hour (0.75 millirad equivalentinmanperhour). Approval(orawaiver)fortheuseofradioactivesubstances must be requested from the administrative authority (Prefecture,SecurityBoard)atleastonemonthbeforethe beginningoftheevent. ContacttheSafetySupervisorforinformationregardingthe required administrative procedures regarding this request. Such request, on plain paper (to be attached to the declarationforthemachineordeviceinoperationincluded intheappendix),mustspecifythetypeandradioactivityof the substances and the group to which they belong, the name and title of the persons responsible for their surveillance and be accompanied by the device’s descriptiveleaflet,adrawingofthedevice’sinstallationon the stand and a document drawn up and signed by the installer certifying compliance with the present provisions. No device of this type may be started if the authorization requestwasnotsubmittedontime. WARNING: stands where radioactive substances are presented must be built and decorated with M1 class materials. 9.2 - X-rays Authorization to present devices emitting X-rays on the stands may only be granted if they and their accessories complywiththerulessetforthinstandardNFC74-100. Inparticular,thefollowingmeasuresmustbetaken: • removing superfluous objects from around the x-ray generatorandthesampletobeexamined, • materializing and signposting the area not accessible to thepublic, • the leakage exposure rate must not exceed 0.258 micro coulombperkiloandperhour(1milliroentgenperhour) atadistanceof0.10mx-raygeneratorcore. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS Approvalfortheuseofx-raymachinesmustberequested from the administrative authority (Prefecture, Safety Board)atleastonemonthbeforethestartoftheevent. ContacttheSafetySupervisorforinformationregardingthe required administrative procedures regarding this request. Such request, on plain paper (to be attached to the declarationforthemachineordeviceinoperationincluded in the appendix), must be accompanied by the device’s descriptiveleaflet,adrawingofthedevice’sinstallationon the stand, and a document drawn up and signed by the installercertifyingcompliancewiththepresentprovisions. No device of this type may be started if the authorization requestwasnotsubmittedontime. (4) Radioactive element classification, based on relative radio-toxicity, shall be that defined in Decree no. 66-450 dated June 20th, 1966 regarding the general principles of protectionagainstionizingradiation. AUTORITÉ DE SURETÉ NUCLÉAIRE (ASN) 6,placeduColonelBourgoin 75572ParisCedex12 Tel:+33(0)143197075-Fax:+33(0)143197140 10 – LASERS 7/8 and the fire protection equipment to the heat energy producedbythelightbeams. Adeclarationforthealllaserinstallationsmustbesentto the administrative authority (Prefecture, Safety Board) at leastonemonthbeforethestartoftheevent. ContacttheSafetySupervisorforinformationregardingthe required administrative procedures regarding this request. Such declaration, on plain paper (to be attached to the declarationforthemachineordeviceinoperationincluded in the appendix), must be accompanied by the device’s descriptiveleaflet,andadrawingofthedevice’sinstallation onthestandandadocumentdrawnupandsignedbythe installer certifying compliance with the present provisions. No device of this type may be started if the declaration requestwasnotsubmittedontime. 11 - EMERGENCY RESOURCES Emergencyresourcesmustremainconstantlyvisible. Access to various emergency resources (fire hydrant and hydrant stems, first aid hose systems, telephones, extinguishers, smoke release hatches, etc.) must remain continuouslyunblocked. 12 - OPERATING INSTRUCTIONS TheuseoflasersintheexhibitionHallsshallbepermitted subjecttocompliancewiththefollowingprovisions: in no case shall the public be subjected to the direct or reflectedlaserbeam,thedeviceanditsancillaryequipment mustbesolidlyattachedtostableelements, • the device’s surroundings and the area covered by the beam must not contain elements reflecting the relevant wavelengths, • thehousingcontainingthelaseranditsopticaldeviation systemmustbeclassIorII(inaccordancewithstandard NFC20-030), • Exhibitors must ensure, during testing outside the presence of the public, the absence of reaction from materials used for fitting-out and decorating the stand, Itisprohibitedtocreate,ontheexhibitionsurfaces,inthe stand,andinclearanceareas,pilesofcrates,wood,straw, cardboard,etc. Periodic(daily)cleaningmustremovedustandwasteofall types from the premises. All waste and debris from cleaningandsweepingmustberemovedeachday,before the opening to the public and be removed from the establishment. On stands fitted with a first aid hose system, clearance of one metre next to the device must be left free of any equipmentuptothepublictrafficalleyway. The presence of panels or cloth masking the device is absolutelyprohibited. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS REGULATIONS FIRE&PANICRISK PREVENTIONREGULATIONS 8/8 SUMMARYOFFRENCHANDEUROPEANEQUIVALENCES M0orAEuropeanStandards=Noncombustible M1orBEuropeanStandards=Nonflammable M2orCEuropeanStandards=Flammablewithdifficulty M3orDEuropeanStandards=Moderatelyflammable M4orEEuropeanStandards=Easilyflammable DOCUMENTTOBESUBMITTED AUTHORIZED Wood(notlaminate)agglomeratedplywood Wood(orwoodcomposite None-(M3assimilatedmaterials) )>18mmnotlaminate lath Wood<18mm&>5mm Wood>18mm,laminate Plywood-Agglomerate <5mmwoodbased composite Carpetsontheground Fabricsandsurfacing walltextiles Plasticmaterials(plaques, letters) M3originalorDEuropeanStandards ReportM3(orLabelsonmaterials) M1orfireproofedonbothsideswithpaint, varnish,saltsbyanapprovedapplicatorB Europeanstandards Natural:M4orEEuropeanStandards Synthetics:-M3orDEuropeanstandards ReportsM1orfireproofingcertificatewithname oftheproduct,descriptiveleaflet,application date Reports M1ouignifugéouBnormesEuropéennes Reportsorfireproofingcertificatewithnameof theproduct,descriptiveleaflet,applicationdate M1orBEuropeanStandards ReportsM1 Paint PermittedonM0,M1supportsorwood (nitrocellulosepaintprohibited) Reportsregardingsupports Free-hangingdecoration (paper,cardboard) 1orfireproofedorBEuropeanstandards Reportsorfireproofingcertificatewithnameof theproduct,descriptiveleaflet,applicationdate Floraldecorationsmade ofsyntheticmaterials M1originally(fireproofingprohibited)orB Europeanstandards ReportsM1 Bondedorclipped decoration(paper Furniture Glazing Nosubstantiationrequiredifbondedover theentiresurfaceorclippedevery5cm. SplitInstallation Largefurniture:M3orDLightstructures:M3 orDPadding:M4orEEnvelope:M1orB Reinforced,tempered,ply Reportsorfireproofingcertificate(so substantiationrequiredifrentedfurniture) Reports,certificates orsubstantiationsuchasaninvoice WrittenresponsebytheSafetySupervisor Requestapproval OtherMaterials N.B.:ReportsonlyfromapprovedFrenchlaboratoriesundercurrentregulationsasofNovember1998or,byequivalence,officially recognizedbyanyreportcorrespondingtoEuropeanStandardsapplicablewithinUnionMemberStates. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES 1/3 CUSTOMS IMPORTANT: CUSTOMS INFORMATION Tel.fromFrance:+33(0)811204444(€0.06/min) Tel.fromabroad:+33(0)172407850 Website:www.douane.gouv.fr/ EconomicRegimesOffice Customsandexciseduties Open:MondaytoFriday Time:9:00am–5:00pm BRINGING MATERIAL THROUGH FRENCH CUSTOMS FROM OVERSEAS (NOT INCLUDING EU) During the SILMO, the Parc des Expositions de Paris Nord Villepinte exhibition grounds are grantedtemporaryadmissionbycustoms. This temporary admission starts the day the material enters the exhibition Halls and ends 30daysaftertheexhibitioncloses. ForeignmerchandisemustbeinspectedbycustomsbeforeitreachesExhibitors’stands. GENERAL COMMON LAWS Arrival of goods: Goods must be presented to the Customs Office by an accredited customs clearance officer withoneofthefollowingdocuments: 1) Transit document: Adeclarationmadeinacustomsofficeataroadborder,portorairportuponthegoods’arrival in French national territory or in their country of origin should customs agreements exist betweenthiscountryandFrance. Documents to provide with the transit document: • Aninvoice(5copies) • ACMRforroadtransportation,anairwaybillforairtransportationorbillofladingforsea transportation • Apackinglist • Descriptionoftheapparatus(ifmachines) Important:Anyapparatuswhichistooperateonstandsmusthavedocumentationtocertify itsconformity. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES 2/3 CUSTOMS Temporary admission: Undernocircumstancesdotheabovedocumentsconfertemporaryadmission. Upon arrival at the exhibition’s customs office, goods must be immediately declared for temporary admission via an on-site customs clearance agent (go to your online EXHIBITORS AREAforalistofofficialagents). After the declaration has been recorded, goods may potentially be checked by customs officers. They cannot be sent on to the exhibitor’s stand until all these formalities have been completed. For the duration of the event, goods must be presented at the stand whenever customs authoritiesrequestit. Important:Temporaryadmissionisonlyconferredfortheexhibitionwhichisthesubjectof thisdocument.Noapparatusmayleavethestandunderanycircumstancesuntilthe formalitiesforoutgoinggoodshavebeencompleted. Outgoing goods: Asindicatedabove,noforeigngoodsfromnon-EUcountriesmayleavethepremisesuntilone ofthenecessarydeclarationshasbeensubmittedtothecustomsofficeviathesamecustoms clearanceofficerwhooversawtheprocedureforentryonsite. Apparatuscanonlyleavethepremisesonceoneofthethreefollowingprocedureshasbeen completed: 1/Re-export 2/Transitunderthecontinuouscontrolofcustomsofficialstoanothercustomswarehouseon Frenchnationalterritory 3/UseonFrenchmetropolitanterritory Inthiscasetheapparatusmustbedeclaredforusebythesamecustomsclearanceofficerwho receivedfromtheimportertherelevantdutiesandtaxesonbehalfofthetaxauthorities. Important:Allproceduresoverseenbycustomsclearanceofficersareattheexhibitor’sown expense. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES 3/3 CUSTOMS ATA Carnet systems for exhibitions (Excludesfoodproducts) TheATACarnetcanbeusedforgoodstobeexhibitedorusedatanexhibition. Thisinternationaldocumentcanbeusedinplaceoftheformalitiesreferredtoinparagraph1 (transitdocument). EntryformalitiescanbedoneatthebordertoEuropeanUnionterritory(orportorairport). Attheendoftheevent,re-exportcanalsobedoneattheEUterritoryborder.Thedeadlinefor re-export may also be established at the EU territory border. The re-export deadline is established in accordance with the dates defined by the country which issued the Carnet, providedthattheexpirydateoftheCarnetisnotexceeded. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETYINSTRUCTIONS IMPORTANT 1/14 Legislation regarding the Prevention of accidents at work imposes health and safety protection coordinationforanyworksiteplacingatleasttwocompaniesorself-employedworkersinthepresence ofoneanother. The Exhibitor Instructions communicated to you defines all the measures set in place to prevent risks arising from the interference of the activities of the various people working on this event. This document was drawn up at the request of the show organizer by the coordinator Mr Christophe MONNIERinaccordancewiththeprovisionsdefinedbythetextsinforceandinparticularthefollowing law: Law of 31.12.1993 nr 93-1418 and the decree of 26.12.1994 nr 94-1159 modified and complemented by the decree nr 2003-68 of 24.01.2003 You are therefore asked to study it and apply the regulatory measures defined in this document. This General Coordination Plan cannot replace the provisions of the Code of Work. It does not in any way reduce the responsibilities and duties of the companies working on the site. For SILMO 2016, this coordination mission is carried out by the COMEXPOSIUM Company via a delegatedcoordinatorassistedbyateamofexpertswhomakeupthesafetygroupofSILMO 2016. This document is a General Health and Safety Protection Plan Intended for the exhibitor, his suppliers and sub-contractors Founded on general prevention principles, namely: Toavoid risks Toevaluate riskswhichcannotbeavoided Tocombat risksatsource Totake accountoftechnicaldevelopments Toreplace what is dangerous by what is notorbywhatislessdangerous. Toplan prevention measuresbycoherentintegrationoftechniques,workorganizationandworking conditions. • Totake collective protection measuresgivingthempriorityoverindividualprotectionmeasures • • • • • • SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS 2/14 The exhibitor has a duty and legal obligation to: 1°) Validate the Safety Instructions Notice on the website of the show. 2°) Pass on the information about these instructions to all service providers appointed by himself who work during the assembly and dismantling periods on his stand. IF YOUR STAND IS • • • • Installedbyseveralindependentcompanies(sub-contractorsincluded), includesamezzaninefloor, Includespartitionsheight>3meters IfYEStoatleastoneofthese You must appoint an HEALTH AND SAFETY COORDINATOR Law of 31/12/93 nr 93-1418 and the decree of 26/12/94 nr 94-1159. For the assembly and dismantling periods and communicate his contact details together with his st GHSPCP (General Health and Safety Protection Coordination Plan) to the D.Ö.T Company before: 21 August 2016. Your decorator/stand builder or yourself are not allowed to carry out this mission. Only a Health and Safety Coordinator having an official certificate of competence is allowed to carry out this mission. D.Ö.T / SILMO 2016 81ruedeParis-92100BOULOGNE Fax:+33(0)146057648-E-mail:[email protected] OBLIGATORY Duringtheassemblyanddismantlingperiods,accesstotheexhibitionHallswillbeauthorisedonlyto peoplewearinganAssembly/Dismantlingbadge. Obligation of protection reminder Cf: Chapter VIII-2 of this document You are reminded that wearing safety shoes (reinforced toe caps + anti-perforation soles) is obligatory for anyone who enters the show site during these periods. For all people working from elevated platforms and any task presenting a risk, wearing a hard hat is compulsory. TobeacceptedintotheHalls,electricaltools,fixedorportable,mustbefittedwithavacuumordust collectionsystem.Art.R4412-70ofcodeofwork. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS 3/14 ASSEMBLY & DISMANTLING DATES FOR BARE STANDS EXHIBITORS HALLS ASSEMBLY DISMANTLING 5A & 6 The20September2016from8.00amto7.00pm The21September2016from7.00amto8.00pm The22September2016from7.00amtomidnight The26September2016from6.30pmtomidnight The27September2016from7.00amtomidnight The28September2016from7.00amto2.00pm FITTED STANDS EXHIBITORS HALLS ASSEMBLY DISMANTLING 5A & 6 The22September2016from7.00amtomidnight The26September2016from6.30pmtomidnight The27September2016from7.00amtomidnight IMPORTANT Onthelastassemblyday,nomotorisedvehiclewillbeallowedintotheHalls(unlessspecialdispensationhasbeengrantedbythe Organizer). th In the dismantling period, on 26 September 2016, motorised vehicles may only work after 7.00 pm in the halls. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS 4/14 CONTENTS I.GENERALINFORMATIONABOUTTHEOPERATION II.RENSEIGNEMENTSADMINISTRATIFS II.ADMINISTRATIVEINFORMATION III.GENERALORGANIZATIONOFTHESHOW IV.HANDLINGCONDITIONS V.CLEANING VI.INSTALLATIONSAVAILABLEDURINGASSEMBLY ANDDISMANTLING VII.ACCESCONTROL VIII.PROTECTIONS IX.GENERALRULESOFCONSTRUCTION X.FIRESAFETY XI.ORGANIZATIONOFEMERGENCIES XII.THEINDIVIDUALHEALTHANDSAFETYPROTECTION PLAN I. GENERAL INFORMATION ABOUT THE OPERATION I. I. DEFINITION The Exhibitors’ Safety Instruction is a document written and devisedbytheCoordinatordefiningallappropriatemeasures to prevent hazards arising from the interference of the activities of different companies during assembly and dismantlingofSILMO2016. ItmustbecommunicatedtoallExhibitorswhomusttransmit it to their stand designer /suppliers when they have named them. It enables them to inform suppliers and subcontractors about the special measures to apply to ensure safetyatwork. majorstructuresandofallgeneralorlocalelementsrelating totheexecutionofthework. b)Perfectlyunderstoodalltheconditionsforcarryingoutthe work and have been made fully aware of their importance andtheirparticularfeatures. c)Madeadetailedvisitofthesiteandtakennoteofallthe physical conditions and all constraints pertaining to the places of work, accesses and surroundings, to the ready executionofthework,andtotheon-goingorganizationand operationoftheworksite. I. 2. COMPOSITION TheSafetyInstructionsthatmustbevalidatedonthewebsite show. The safety regulations of the Venue and the Fire Safety instructionsareavailablefromtheOrganizer. I.3. DEFINITION OF THE COMPANY Any firm that provides services to the Exhibitor, and is charged with creating the infrastructures of the stand is consideredasacompany.TheExhibitorisresponsibleforhis ownsuppliersandsub-contractors. Thecompanies,theircontractorsandsun-contractorsremain responsible for their own employees and for the means providedtoworkinthebestconditions. The company director remains responsible for the safety of his employees and is required to implement the means necessarytoavoidandcontrolrisks. The courts severely sanction any damage to the health or safetyofemployeesandtheciviland/orpenalliabilityofthe companydirectorcanbeinvoked. Thecompaniesdeclarethattheyhavetakennoteofthetexts quotedinthisdocument,aswellasthegeneralconditions oftheshoworganizationdepositedwiththeOrganizer. In addition, it is supposed that companies have: a)Takennoteofplansanddocumentsusefulincarryingout the work, and of event technical files, and that they have taken due note of the sites, places and installation areas of SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS 5/14 II. ADMINISTRATIVE INFORMATION II.1. THE PARTICIPANTS II. 1. 1 General organization TheCOMEXPOSIUMCompanyactsasthegeneralexhibitionmanagerofSILMO2016 ORGANIZER / EMPLOYER COMEXPOSIUM 70,avenueduGénéraldeGaulle ImmeubleleWilson 92058PARISLADEFENSECedex-France Tel:+33(0)176771111 TECHNICAL&SECURITYDIRECTOR Mr Jérôme HUNAULT Tel:+33(0)176771365 Email:[email protected] INSURANCEAGENCY–Civilresp/Dam.toproperty SIACI SAINT HONORÉ 18,ruedeCourcelles 75384PARISCedex08 MonsieurPhilippeHUET Tel:+33(0)144202981 Email:[email protected] GENERAL SHOW DIRECTOR Mr Eric LENOIR Tel:+33(0)176771111 E-mail:[email protected] TECHNICAL&SECURITYMANAGER Mr Fabrice DIGLE Tel:+33(0)176771271 Email:[email protected] TOWNHALL MAIRIE DE VILLEPINTE Placedel’HôteldeVille 93240VILLEPINTE Tel:+33(0)141525300 II. 1. 2 HSP Coordination SPS / Fire Safety HSP COORDINATOR FIRE SAFETY REPRESENTATIVE D.Ö.T: 81ruedePARIS-92100BOULOGNE-France Tel:+33(0)146051785-Fax:+33(0)146057648 Email:[email protected] AFS Conseils & Sécurité 76,rueBaudin 93130Noisy-le-Sec Tel:+33(0)670619511-Fax:+33(0)141550721 Email:[email protected] Thedatesofpresenceofthefirerepresentative.hasn’tbeendefined. Thedateofthesafetycommitteetourofinspectionhasn’tbeendefined. FIRE PROOFING Groupement NON FEU 37-39,ruedeNeuilly-BP249-92113CLICHY-France Tel:+33(0)147563148 Groupement Technique Français de l'Ignifugation 10rueduDébarcadère-75017PARIS-France Tel:+33(0)140551313 EXPERT IN THE SOUNDNESS OF MAJOR STRUCTURE SOCOTEC Centred'AffairesParisNord-France LeContinental–BP306 93153LEBLANCMESNILCedex Tel:+33(0)148654237 SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS 6/14 II.2. DEFINITION OF WORK AREAS VENUE HALLS VIPARISPARISNORDVILLEPINTE-BP68004 95970ROISSYCHARLESDEGAULLECedex Accueil:Tel:+33(0)140682222 ServiceExposants:Tel:+33(0)140681616 5A & 6 II.3. THE OFFICIAL BODIES INSPECTION OF WORK CRAMIF 1,avenueYouriGagarine 93000BOBIGNY Tel:+33(0)141605300 ServicedesrisquesProfessionnels. MrFrançoisGUINE 17/19,avenuedeFlandres 75019PARIS–France-Tel:+33(0)140053816 O.P.P.B.T.P. Glossary 1,rueHeyrault 92660BOULOGNECedex-France Tel:+33(0)140316400 CRAMIF:CaisseRégionaled'AssuranceMaladied'IledeFrance OPPBTP:OrganismeProfessionneldePréventionduBâtimentetdes TravauxPublics II.3. EMERGENCY SERVICES ON THE SHOW SITE: Timetable displayed on the hall plans EMERGENCY POST GENERAL SURVEILLANCE POST Tel:+33(0)148633049 Hall6postopenfrom22to27September Informationdisplayedatthehallsentrance FIRE SAFETY Tel:+33(0)148633049 OFF SITE FIRE SERVICE POLICE STATION 1,ChemindesVaches 93290TREMBLAYENFRANCE Tel:18ou112(mobile)ou+33(0)148606948 SAMU 125,ruedeStalingrad 93000BOBIGNY Tel:15ou+33(0)148964444 1/3,rueJeanFourgeaud93420VILLEPINTE Tel:17ou+33(0)149634610 NEAREST HOSPITAL HôpitalIntercommunalRobertBallanger BdRobertBallanger 93602AULNAYSOUSBOISTel:+33(0)149367123/22 SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS 7/14 III. GENERAL EVENT ORGANIZATION III.1. GENERAL PRESENTATION OF THE SHOW Cf.Exhibitor’sguide III.2. SCHEDULES OF USE OF HALLS, publicopening HALLS DATES & TIME 5A&6 rd th From23 to26 September2016from9:00amto6:30pm III.4.2 Traffic movements inside the Halls. No delivery or private vehicles will be allowed in the Halls, during the assembly and dismantling periods, without access authorisation from the organizer. Means of transporting people (motorised or not) such as: scooter, bicycle, roller blades, electric vehicles, etc. are prohibited in the Halls. Plans showing traffic movement areas, position and contact details of emergency services, the location of open toilet facilities, access schedules for machines and the storage areaswillbepostedattheentries. The free movement (of men and lifting equipment) around the stands must be possible at all times during assembly and dismantling. The security aisles define on the exhibition general plan must be respected and kept free of any materials or crates. There must be no storage or parking on the traffic movement areas defined on the plan of the Halls. III.3. VARIOUS SERVICE PROVISIONS Cf.Exhibitor’sguide III.4. SITE CONSTRAINTS III.4.1 Traffic movements inside the park The temporary occupation of this site implies compliance withthestandardsandconditions(Timesofaccess,parking, speed etc.) defined by the regulations in force in this enclosure and its surroundings. These regulatory texts, as wellasthesitespecifications,canbeconsultedbycontacting theOrganizer. Managementofparking(anditsduration),trafficmovements and access to delivery vehicles displaying authorisation will besetuparoundtheHallsandinthepark. Any vehicle even parked, must be able to be identified. Private vehicles must be parked in the car parks. They must not approach the surroundings of the Halls. RESPECT INSIDE RESPECT OUTSIDE • Thepathsmarkedoutforfireservicesandtraffic movementsareas • Thestorageareas • Theenvironmentbyusingnon-pollutingmachines • • • • Accessroutesforfireservices Parkingareas Unloadingareas Accessgate IV. HANDLING CONDITIONS IV.1.GENERAL REMARKS The movement of machines presents risks and must be reduced to a minimum by strict management and distributionoftheequipment. Companies listed by the Exhibitor are asked to set up means of identifying the machines and the men (stickers, identificationjackets,etc.). Lifting and handling equipment must satisfy the requirementsofcurrentregulations. Theymustbekeptingoodworkingorderandhavesatisfied regularinspectionsinconformitywiththeArticleR4535-7 ofCodeofwork. Machines must hold the following documents Article L 4711-1oftheCodeofWork • Validinsurancecertificate. • Valid certificate of conformity (checking report of lifting devices). It is strictly forbidden to climb on machine not provided to transport passenger. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS Necessary organizational measures should be taken to limit recoursetomanualhandlingtotheminimum(ArticleR45413oftheCodeofWork). However,whenitcannotbeavoided,theemployermusttake appropriate measures or put at disposal to the workers, suited measures, to limit physical effort and to reduce incur risks during the handling (mechanical assistance, grasping means). The weight of the loads must be reduced and the working post must be adjusted to do the handlings in the best conditions(workingspace,reductionofthedistancethatthe loadsneedmoving…). The staff must be trained in the risks of handlings. The load must not split when it is moved. For the handling of glass panels, it is recommended to use suction cups. In the same way,forhandlingplywoodsheets,theuseofhandlingclipsor panelcarriersisrecommended. Thecontainersofbulkloadsintendedtobehungonworking equipment used for lifting must be capable of resisting the effortsundergoneduringtheloading,transport,handlingand storage of the load and be fitted to prevent the untimely collapseofallorpartoftheloadduringthesameoperations. The use of straps to fix the loose loads on the forks of the lifting trucks is obligatory. 8/14 The work area of the crane must be secured. The certificate of conformity of this equipment must be available for inspection. It is essential that the company, which provides the equipment, exclusively carries out the maintenance and operation of all lifting gear. This equipment is the sole responsibilityofthiscompany. Whateverthemeansofliftingused,theusersmusttakecare nottoworkoveranyotherworkersandto take all necessary safety provisions. Movements with loads in high position are banned, except with the presence of a guide who must warn the people of this operation. On the car parks or the outside exhibition areas, the motion space of the crane in relation to the surrounding hightension cables must be taken into account. The jib must not approach these cables at less than 5 meters. (Article R 4534108 of the Code of Work). The maximum load indications of each strap must be respected. The lifting works must be done in accordance with the ArticlesR4534-95à102oftheFrenchCodeofWork. IV.2. USE OF MACHINES WITH AN ENGINE The drivers must be at least 18 years of age and hold driving permits issued by the employer as well as the CACES (safe driving aptitude certificate) and the Special Medical Fitness Certificate. The speed limit must be respected for any movement outside the Halls. It must be reduced and appropriate inside the Halls. These documents must be available for inspection on the site. The users of these machines must comply with the manufacturer’s instructions. No carrying a passenger, no lifting a person if the machine is not intended for the purpose, USE OF NON-POLLUTING MACHINES adapted to the tasks, places, loads and configuration of the ground. • The speed limit must be respected for any movement outsidetheHalls. • ItmustbereducedandappropriateinsidetheHalls. IV.3. LIFTING REGULATIONS Lifting machines must be used only for transportation and lifting of equipment and material. Lifting and transportation of people must be done only with specially designed equipment. For any use of a crane, a special request must be made to the Organizer. This request must specify where the crane will beoperating and the technical constraints of use and assembly. These constraintsmustappearinthecompanyI.H.S.P.P. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS REMINDER, IT IS FORBIDDEN: • Todriveatruckwithoutadrivinglicence. • To allow your truck to be driven by an unauthorised person. • Toliftaloadgreaterthanthemachine’scapacity. • Toincreasethevalueofthetruck’scounterweight. • Toliftapoorlybalancedload. • Toliftaloadwithonlyonearmofthefork. • Tomovearoundwithahighload. • Tobrakesharply. • Totakecornersathighspeed. • Nottoobservetrafficsigns. • Tousetrafficlanesotherthanthoseestablished. • To carry people on trucks not specially designed for the purpose. • Toleavetheenginerunningintheabsenceofthedriver. • To lift people with trucks not specially designed for the purpose. • Toabandonatruckinthemovementaislesoronaslope. • To leave the ignition key in the vehicle when the driver is absent. • To park or go under a fork in the high position, even unloaded. • To smoke near a charging battery or while thermal trucks arebeingfilled. • Toplacemetalpartsonaccumulatorbatteries. I IV.4. STORAGE It is imperative for materials to be stored on the aisles (or parts of aisles) reserved for this purpose, in the enclosure of the worksite or the storage areas when they are provided. Forthispurpose,trafficmovementplanswillbepostedatthe accesses to the Halls. The schedules and restrictions of use willbespecifiedontheseplans. All workers are asked to respect these plans scrupulously. Attheendofassembly,racks,pallets,etc.mustnotbestored insidetheshowandintheareasbehindthecladdings(unless authorisedtodosobytheOrganizer). Machines must not be stored, during the assembly / dismantling period, in the traffic movement aisles, but in a storage area determined with the Organizer’s technical managers. The companies working for the building of the stand (and their subcontractors) must schedule the arrival of their equipment and materials, their distribution, as well as the departureofemptypackagingsothattheydonotinterfereat any time with the movement of machines and men in the aisles For the period when open to the public, no machine will be allowedintheenclosureoftheHalls. 9/14 Exhibiting companies are responsible for cleaning their site and removing their rubble and waste of all kinds. They must plan the reservation and removal of skips and organise how they are filled. It is the responsibility of each workereithertocovertheskips,ortoweighdowntherubble topreventitfromflyingaround. You are reminded that no worker must climb into a skip or truck. During the dismantling period, removal of the different decoration parts must not block the circulation of men and machines in the aisles around the stand. VI.INSTALLATIONS AVAILABLE DURING ASSEMBLY AND DISMANTLING PERIODS VI. 1. TOILETS To ease the general organization of assembly and dismantling, and improve working conditions, the Organizer will ask the Venue to open additional communal toilet facilitiesintheexhibitionHallsfromthefirstdayofassembly totheendofdismantling.Amaintenanceservicewillseeto thecleaningofthesefacilities. The toilet facilities that are open will be indicated on the plans posted up at the Halls entrances. VI.2. CLOAKROOMS / CANTEEN The company is required to place cloakroom facilities (if necessary) at their staff’s disposal, in application of current legaltexts,availableforconsultationfromtheOrganizer. Therewillbenocanteenformeals. VI.3. TELEPHONE ON SITE Each company places at its staff’s disposal a telephone accessiblewhenthesiteisopenforwork. VI.4. ACCOMMODATION The Company is responsible for providing off-site accommodationforitsstaff. VII. ACCESS CONTROL VIII.1. WORKFORCE VIII.1.1. MEDICAL FITNESS All personnel called upon to work on the site must be recognised as being medically FIT, and have undergone the obligatorymedicalexaminationsandvaccinationsassociated with the exercise of their profession, as well as those required by Medicine of Work. These certificates must be availableonthesite. V. CLEANING The worksite must be kept clean at all times to prevent hazards that could be caused by rubbish blocking the aisles around the stand. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS VIII.1.2. SAFETY TRAINING In conformity with current regulations, and at its own responsibility, the company must ensure that every worker arriving on the site has attended safety-training sessions (presentationofspecialrisks,conditionsoftrafficmovements outsideandinsidethesite,safetyconditionsapplicablewhen carrying out work, special safety instructions, explanation of theoperatingmethod,follow-upofpreventivemeasuresthat havebeendefinedforeachtaskintheIndividualSafetyand HealthProtectionPlan). VIII.2. REGISTERS VIII.2.1. LEGAL REGISTERS The enterprise must hold obligatory legal documents at the site, as they may be asked for by administrative inspection services. VIII.2.2. JOINT SITE VISITS When they arrive on the assembly and dismantling site, companies who have never worked on the site before must make a joint inspection visit with the Safety Coordinator of their stand. A site visit file will be established by the Coordinatorandsignedbyeachcompanymanager. Thesafetyandprotectionmeasuresaredefinedwiththesite managersandthestandSafetyCoordinatorinreferencewith the G.H.S.P.C.P established by the Coordinator, taking accountoftheeventG.H.S.P.C.Paccordingtothestateofthe siteatthetimeofthevisitandthewaythevisitiscarriedout. VIII.3. PROTECTIONS The workers are reminded that they must give priority to COLLECTIVE protections over INDIVIDUAL protections, anytimethatitistechnicallypossible. VIII.3.1. COLLECTIVE PROTECTIONS Definition:Standardisedmeansofprotectionsetupbya company(barriers,nets,floor,cladding,guardrails…) designedtoensurethecollectivesafetyofstaffworkingata heightoronanupperfloorduringassemblyanddismantling. This collective protection must be rigid composed of a high and low hand rail and a baseboard, safely attached and must be installed from the outside with appropriate means, before any work is purchased on a storey or at height during assembly or dismantling. It must be removed only after the installation of the definitive protection or partition. The stairs must be assembled as a priority and made safe by guardrails as soon as they are set up. The stairs cavities must be protected (closed or with a guardrail). Material deliveries access must be secured. For the dismantling all these protection must be reinstalled. Each company must describe the collective protection planned in his Individual Health and Safety Protection Plan. 10/14 The company in charge of the building and dismantling of the double decker marquee must put in place for the delivery access, a system that provide at anytime a collective protection for the people working on the mezzanine. The company must see to the maintenance of collective protectionsandwillbeheldresponsibleifworkiscarriedout in areas not prepared and not protected. It must intervene immediatelyatanydirectrequestfromthestandCoordinator torestoreorsupplementtheseprotections. Article R 4323-65: The collective protection devices must be designed and installed in order to avoid a gap at workstation access points namely when a ladder or staircase is used. However when such a gap is unavoidable measures must be taken to ensure equivalent safety. If a company fails to establish collective protection, the absence of which constitutes a risk for other trades and its own staff, the exhibiting company will have these collective protectivemeasuressetupbyacompanyofitschoice,atthe expenseofthedefaultingcompany. Any ensuing work stoppage will also be charged to the defaulting company. No double storey building is planned on this exhibition. Refer to the chapter IX. of this document: “General rules of construction” IX.2. "Working at height". SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS VIII.3.2. INDIVIDUAL PROTECTIONS When collective protection system cannot be implemented, theworkersprotectionmustbeensuredbyappropriate“stop falling”systemthatcannotpermitafreefallasmoreasone meter.Whenthiskindofequipmentisused,theworkermust neverleavealone. Companies that have to intervene during the assembly and dismantling periods must, among other things, provide their staff with the following individual protection equipment (IPE): • Workclothes, • Glovesadaptedtothework, • Safetyhardhatscompliantwithstandards, • Safetyshoes(reinforcedtoes+anti-perforationsoles), • Safety harness that conforms to standards when the collective protection provisions cannot be implemented. (ArtR4223-61oftheCodeofWork), • Weldingmaskandsafetygogglesduringwelding,unloading orgrindingwork. Respect for these provisions, and the upkeep and good condition of this equipment is the responsibility of each company. Wearing safety shoes (safety toe-caps + anti-perforation soles) is compulsory for any person entering the show site during the assembly and dismantling periods. For all people working from elevated platforms and any task presenting a risk, wearing a hard hat is compulsory. IX.GENERAL RULES OF CONSTRUCTION IX.1. DECORATIONS Thedecorationsmust,asmuchaspossible,arriveonthesite readytobeassembledsoastoreducebuildingoperationsto theminimumandtheriskswhichresultfromthis.Theymust bedesignedforsafe,cleandismantling. It is strictly forbidden to « blow out » panels and partitions during dismantling. IX.2. WORKING AT HEIGHTS Decree nr 2004-924 of 01.09.2004 concerning the use of work equipment made available for temporary work at a height and integrating new provisions in the labour code (Articles R 4323-58 to R 4323-90). It is obligatory for companies installing marquees, tents or structures, during the assembly, maintenance and dismantling periods, to set up collective protection measures appropriate for any work on roofs by their staff. The methods considered for carrying out this work must appear in the company I.H.S.P.P. In any case the people working for the building and dismantling must have a certificate to work at height and a valid authorization from his employer.Ladders, stepladders and footstep platforms must not be used as work positions. (Article R 4323-63 of the Code of Work) 11/14 Howeverthesefacilitiesmaybeusedwhenitisimpossibleto use equipment providing a collective protection to the workersorwhentheriskhasbeenevaluatedaslowandthe workisforashortandnon-repetitivelengthoftime(ArticleR 4323-63oftheCodeofWork). The companies may work at heights with scaffoldings or mobile platforms. Approved personnel must assemble scaffolding, respecting the directives or instructions of the manufacturer; the platforms must be correctly positioned, guardrails and stabilitypropsmustbeinplace. Article R 4323-77: Scaffolding must be fitted on the exterior sides with collective protection devices as outlined in paragraph 2 of the Article R 4323-59. The scaffolding must be level when it is used. The wheels of mobile scaffolding must be locked in position when the scaffolding is in use. No worker must remain on mobile scaffolding while it is being moved. Fortheassemblyofscaffolding,steps,etc…,itisessentialfor companiestoequiptheirpersonnelwithhardhatsandsafety harness, in addition to safety shoes and gloves. They must make sure that the use of these I.P. by their personnel is effective. Legal restrictions concerning work at heights must be respected. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS IX.3. MEASURES TAKEN CONCERNING CO-ACTIVITY Companies must provide a detailed assembly and dismantling schedule in their I.H.S.P.P Any work which might create a situation placing workers over each other must be resolved by carrying out the work at different times, or with special protection arrangements. Within the framework of the timetable of assembly and dismantling work, companies acting on the same site must take all appropriate individual protection measures to prevent hazards caused by superimposed work, particularly during the installation and dismantling of gantries, signposting,lightadjustmentsofthealtimetricreadings,and assembly/dismantlingoflargeequipment. The Exhibitor or his project manager must set up a work schedule taking into account a chronological order of assembly, to avoid tasks at different levels in the same site andtocarryoutthesetasksusingsuitablemeans. • These means can be common to several workers or companies. • Thischronologicalorderwillbeinthesamewayadaptedto dismantling. The external working areas must be marked out or cordoned off with barriers so that they are inaccessible to people not involved with the assembly. The fences or barriers must in all cases be stabilised so as not to overturn if there are gusts of wind or if knocked into by a vehicle. IX.4. SITE CONNECTIONS / LIGHTING IX.4.1. REGULATIONS Electrical installations on the worksite must be carried out accordingtoregulationsinforce. The personnel working on the electrical installations must havereceivedtrainingandmustholdanapprovalcertificate underpublicationUTEC18510. Moreover, companies, which use the installations, are requiredtopointoutimmediatelyanydefectordeterioration theyobservetothemanagersoftheExhibitionsite. An approved body must inspect the worksite electrical installationbeforebeingbroughtintoservice.Thisinspection report must be available for consultation and kept on site throughouttheassemblyanddismantlingperiods. To avoid risks of electrocution, deterioration of electricity cables,andthemultiplicationofconnectionsonasameline, unauthorised connections on the existing power points in the Halls will not be tolerated. Alltheworksitecablesandextensionleadsmustbeingood conditionandcompliantwithcurrentstandards. Worksite electricity cabinets are available from the Park. 12/14 unauthorised connections on the existing power points in the Halls will not be tolerated. Alltheworksitecablesandextensionleadsmustbeingood conditionandcompliantwithcurrentstandards. Worksite electricity cabinets are available from the Park. IX.4.2. LIGHTING Thegenerallightingintheworkareasmustbecompliantwith lighting regulations determined by Decree nr 83.721 of 2 August1983andrepeatedintheCodeofWorkinArticlesR 4223-1to12. Lightintensityinworkingareasmustbeatleast120Lux,and 60Luxintrafficmovementaisles. The assembly and dismantling of decors may obscure the light in the Halls (roofing, canopy, stretched ceiling, mezzaninefloor…),soprovisionallightingmustbeprovided. IX.5. PREVENTION OF RISKS OF PROFESSIONAL DISEASES 5.1. HAZARDOUS MATERIALS Itisimperativeforanycompanythatneedstousehazardous products to send the safety data sheets to the Safety CoordinatorandtotheFireSafetyControlAgency,andputin placetheprotectionmeasuresspecifiedonthesheet. Companies are informed that any glue, resins, paint and products used must be free from solvent, ether, glycol, and be odourless and antiallergic. IX.5.2. NOISE DISTURBANCE Theuseofnoisymachinesorequipmentmustadherestrictly tocurrentregulations. All necessary methods and provisions must be used (hood, screen, silencer etc…) so as not to exceed the regulatory limitsasregardsacousticlevels. IX.6. RULES FOR USE OF ELECTRICAL TOOLS, FIXED OR PORTABLE To avoid dust, fumes emission or noxious emanations when fixed or portable electrical tools are used (saws, sanders, blowtorches, welding torches, etc…), efficient protection meansmustbeprovided(centralvacuum,masks,glasses…). Only water disc cutters will be allowed for cutting tiles, stones… To be accepted into the Halls, electrical tools, fixed or portable, must be fitted with a vacuum or dust collection system. (Art. R 4412-70 of the Code of Work) The technical traps of the halls must be correctly closed or protected in case of temporary opening to avoid any risk of falling of people. To avoid risks of electrocution, deterioration of electricity cables,andthemultiplicationofconnectionsonasameline, SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS Theseappliancesmustbecompliantwiththestandards(CE), be in good operating condition and fitted with their protective shields. They must in no circumstances be placed in the movement aisles, and the electricity supply must be disconnectedwhentheyarenotinuse. IX.7. WORK INVOLVING HEAT Foranyworkinvolvingheat(grindingorweldingoperation),a “FIRE PERMIT” must be applied for from the venue person in charge. IX.7.1. INFLAMMABLE MATERIALS AND PRODUCTS Gas bottles under pressure must be protected from knocks, falls and heat, and no unauthorised person must be able to haveaccesstothem. It is forbidden to keep or store gas bottles, full or empty, in the hall. IX.7.2. EXTINGUISHING MEANS Communal means: The layout of the stands must not impede access to the emergency systems or fire-fighting equipment such as fitted fire taps, emergency phones, smoke ventilators, extinguishers. All this equipment must be clearly visible and accessibleonapermanentbasis. Specific means for each worker: Each company must plan in his IHSPP the means of preventionsuitedtohisactivityandhisworkzone If necessary, the worker complete by specific means the commonmeansofextinguishing. • Spraywaterextinguisherwithadditive(generalcase). • CO2extinguisher(Insideorneartheelectricalrooms). X. FIRE SAFETY The fire safety regulations are deposited with the Organizer andavailableintheExhibitor’sGuide. The Official Safety Committee is very strict as regards structural construction (construction and decoration materials, solidity and stability of structures, upper floors, emergencyprovisions,electricalfittings,etc...). The decisions taken by the committee during its tour of inspectionareenforceableimmediately. TheOfficialSafetyCommittee(ortheERPsafetyofficer)will carryoutasafetyinspectionvisittotheinstallations.During this visit, the qualified representative of the stand is requested to be present on his stand. The Exhibitor undertakestorespecttheinstructionsofthepersonalsafety expertandthefiresafetyexpert. AtthetimeofthisCommittee’stourofinspection,thestand installationmustbecomplete. TheExhibitor(orhisrepresentative)mustbepresentonthe stand and be in a position to supply fire reaction reports drawnupbyanapprovedFrenchlaboratoryinrespectofall materials used, together with the reports of inspections of electricalinstallations,soundnessofstructures,etc... 13/14 Failuretorespecttheseregulationsmayinvolvetheremoval of materials, or it may be forbidden for the stand to be openedtovisitors. XI. ORGANIZATION EMERGENCIES XI.1. COMPANY EMERGENCY MEASURES The company must have a first aid kit available on the site. Thecontactdetailsoftheshow’semergencyfirstaidpostare indicatedontheHallsplans. Thefirst-aidworkerpresentwithineachcompanyonthesite will provide first aid in the event of an accident. (1 first-aid worker for 10 workers).. They must wear an identification pictogram on an armband orontheirhelmetsandtheirnamesmustbeenteredinthe I.H.S.P.P In case of accident precise: • Thehall • Thestandname • Thelaneandthestandnumber • Numberofpeopleinvolvedandinjurieskinds XI.2. COLLECTIVE ORGANIZATION OF THE SHOW REMINDER OF THE EMERGENCY PHONE NUMBERS EMERGENCY POST: HALL 1 & 6: +33 (0)1 48 63 31 15 FIRE SAFETY & GENERAL SURVEILLANCE POST: +33 (0)1 48 63 30 49 THE EMERGENCY PHONE NUMBERS ARE DISPLAYED AT THE TECHNICALOFFICE. XII. THE INDIVIDUAL HEALTH AND SAFETY PROTECTION PLAN It is obligatory for all the Exhibitor’s service providers to draw this document: - Within 30 days before any assembly for main contracts. - Within 8 days for work of short time and/or finishing work. The working company must send this IHSPP to the Health and Safety Coordinator and to the stand employer AT LEAST 8 DAYS BEFORE THE START OF WORK on the stand. Itgivesadetailedanalysisoftheconstructionandexecution processes as well as the chosen operational methods when theyhaveaparticulareffectonthehealthandsafetyofthe peopleworkingonthesite. XII.1. THE EXHIBITOR The exhibiting company must give a copy of the Safety Instructions drawn up by the show Safety Coordinator to theirserviceprovidersortotheSafetyCoordinatorappointed forhisstand.Thisdocumentdealswiththeselectedgeneral organization measures which are of a nature to have an influenceonthehealthandsafetyoftheworkers. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES EXHIBITORSSAFETY INSTRUCTIONS 14/14 XII.2. COMMUNICATION OF THE DOCUMENT XII.1. THE EXHIBITOR ThestandSafetyCoordinatorisrequiredtocommunicateto every company working on the site (at their request) the names and addresses of the other contracting companies, togetherwiththeirI.H.S.P.P. The exhibiting company must give a copy of the Safety Instructions drawn up by the show Safety Coordinator to theirserviceprovidersortothesafetycoordinatorappointed forhisstand.Thisdocumentdealswiththeselectedgeneral organization measures which are of a nature to have an influenceonthehealthandsafetyoftheworkers. XII.3. AVAILABILITY OF THE I.H.S.P.P. AcopyoftheI.H.S.P.P.mustbeavailableatalltimesonsite forconsultationbythecompaniesconcerned. All the companies working for the exhibitor must give this form to stand employer and to the safety coordinator if the case arises before any work on building site. Itgivesadetailedanalysisoftheconstructionandexecution processes as well as the chosen operational methods when theyhaveaparticulareffectonthehealthandsafetyofthe peopleworkingonthesite. XII.2. COMMUNICATION OF THE DOCUMENT ThestandSafetyCoordinatorisrequiredtocommunicateto every company working on the site (at their request) the names and addresses of the other contracting companies, togetherwiththeirI.H.S.P.P. XII.3. AVAILABILITY OF THE I.H.S.P.P. AcopyoftheI.H.S.P.P.mustbeavailableatalltimesonsite forconsultationbythecompaniesconcerned. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES USINGFOREIGNSERVICEPROVIDERS 1/2 MANDATORY Exhibitorsandstandinstallersmayusenon-Frenchserviceproviders.Theywillbeinformedby the organiser of French regulations regarding the use of a foreign workforce on French territoryduringtheshow’sassemblyanddismantlingperiods,andremindsthemthatitisvery importanttomakethenecessarydeclarations. 1 - PRELIMINARY DECLARATION OF SECONDMENT Whatever their nationality, non-French service providers must complete a preliminary declaration of secondment (déclaration préalable de détachement) which is to be made in France and returned before 10th September 2016 to: DIRECCTE-1,avenueYouriGagarine-93000BOBIGNY-14èmesection Tel:+33(0)141605324-Fax:+33(0)141602297 Email:[email protected] It is important to underline that French law, and in particular provisions regarding working hours and the minimum wage, applies to foreign workers as of the first day of their employmentonFrenchterritory,howeverlongtheyareworkinginFrancefor. Accordingtolaw,noemployeecanthereforeworkinFrance: • Formorethan48hoursaweek:pleasenotethataweekstartsatmidnight(00.00am)on MondayandendsatmidnightonSunday(24.00pm) • Formorethan10hoursaday • Formorethan6hourswithoutabreak(ofatleast20minutes) • Formorethan6daysinasingleweek. All employees working on French territory must receive a monthly gross salary of at least €1466,62 when they work for 35 hours a week, i.e.: €9.67 gross per hour (minimum wage applicableasof1stJanuary2016). SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES USINGFOREIGNSERVICEPROVIDERS 2/2 PROVISIONAL WORK PERMIT Certain foreign service providers must also ask the Direction Départementale du Travail, de l’EmploietdelaFormationProfessionnelle,ServiceetMaind’œuvreEtrangèreforprovisional workpermitsforemployeessenttemporarilyonsecondmenttoFrance; Countries of origin which do not currently require this provisional work permit are: Germany,Austria,Belgium,Bulgaria,Cyprus,Denmark,Spain,Finland,France,Greece,Ireland, Italy, Luxembourg, Malta, the Netherlands, Portugal, the United Kingdom, Sweden, Estonia, Hungary, Lithuania, Poland, Slovakia, Slovenia, Romania, the Czech Republic, Iceland, Liechtenstein,Norway,Switzerland,Andorra,MonacoandSanMarino. Requests for provisional work permits must be made in French and sent no later than 10September2016to: DIRECCTE-1,avenueYouriGagarine-93000BOBIGNY-14èmesection Tel:+33(0)141605324-Fax:+33(0)141602297 Email:[email protected] SOCIAL SECURITY Foreignserviceprovidersmustalsobeabletoprovethattheyhaveup-to-datesocialsecurity protectionforeachoftheiremployeesonsecondmentinFrance: If service providers from the European Union are not staying in France for more than two months,secondedworkerswillcontinuetocontributetoandbeprotectedbysocialsecurityin theirhomecountry. Service providers from outside the European Union must provide evidence that they have organisedsocialsecurityprotection: • Intheircountryoforigin,ifithassignedabilateralsocialsecurityagreementwithFrance; thesecountriesarelistedonthewebsitewww.cleiss.fr. • IftheircountryoforigindoesnothavesuchanagreementwithFrance,theymustaskfora socialsecurityguaranteefromaFrenchorganisation;allcontributionsarepaidtothis organisation:todosocontactURSSAFinBas-Rhin: URSAFF –16,rueContades-67307Schiltigheim–France Tel:+33(0)820395670-Fax:+33(0)388185274 Email:cnfe.strasbourg@urssaf SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES FORMMANDATORYAFFIDAVITwhenusingaservice providerinFranceredisingorestablishedabroad RETURN BEFORE 10TH SEPTEMBER 2016 TO: DIRECCTE-1,avenueYouriGagarine-93000BOBIGNY-14èmesection Tel:+33(0)141605324-Fax:+33(0)141602297 Email:[email protected] EXHIBITOR Companyname:............................................................................................................................................................ Pavilion:…………………………………………Aisle:………………………….…StandNo:………………………………………………………………. Standname:…………………………………………………………………………………………………………………………………………………………….. Address:…………………………………………………………………………………………………………………………………………………………………… Postcode:…………………………………….Town/City:………………………………………………………………………………………………………… Country:………………………………………………..…………………………………………………………………………………………………………………. Tel:……………………………………Fax:………………..………………E-mail:………………………………………………………………………………. Cellphone:……………………………………………………………………………………………………………………………………………………………….. IMPORTANT: SWORN AFFIDAVIT Itheundersigned:………………………………………………………………………………………………….................................................... Actingas:……………………………………………………………………………………………...…..……………………...…………………………………… Forthecompany:……………………………………………………………………………………………………………....……………………...…………… Located:……………………………………………………………………………………………………………………......……………………...……………….. SolemnlydeclarethatI: • understandthemandatoryformalitiesrequiredforaserviceperformedinFrancebyacompanyestablishedor domiciledabroad, • shallcomplyandensurecompliancebymyserviceproviderwithalltheaforementionedformalities. Mandatory Corporate Seal Drawnupandsignedin:……………………… on: ……………………………. Authorizedperson’slastname,firstname, andsignature,precededbythewording “luetapprouvé”[readandapproved] SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES FORM:SECONDMENTSTATEMENT Whenusingforeignlabourbyaserviceprovider 1/2 FORM TO RETURN DRAFT IN FRENCHBEFORE 10TH SEPTEMBER 2016 TO: BYFAXOREMAIL DIRECCTE-1,avenueYouriGagarine-93000BOBIGNY-14èmesection Tel:+33(0)141605324-Fax:+33(0)141602297 Email:[email protected] Companyname:............................................................................................................................................................. Address:………………………………………………………………………………………………………………………………………………………………….. Postcode:………………….City/Town:…………………………………………………………Country:………………………………………………… Tel.:……………………………………Fax:………………..………………Email:…………………………………………………………………………….... IMPORTANT The Secondment Statement must be submitted regardless of the seconded foreign employee’s nationality 1 – SERVICE PROVIDER (EMPLOYER) NameorCompanyName:………………………………………………………………..……………LegalForm:……………………………………… Fullforeignaddress:…………………………………………………………………………………………………………………………………………………. Tel.:……………………………………Fax:………………..………………Email:……………………………………………………………………………….. Employer inscription or registration in the country of establishment Register:……………………………………………………………………….Reference:……………………………………………………………………….. Corporatedirector’s(s’)identity:……………………………………………………………………………………………………………………………… 2 - SERVICE PROVIDER’S REPRESENTATIVE IN FRANCE (IDENTITY OF THE REPRESENTATIVE FOR THE DURATION OF THE SERVICE) Lastname:…………………………………………………………..………………………………Telephone:………………………………………………… Address:…………………………………………………………………………………………………………………………………………………………………… 3 – SERVICE PROVIDER’S PRINCIPAL NameorCompanyName:………………………………………………………………..……………………………………………………………………… Address:………………………………………………………………………………………………………………………………………………………………….. 4 – SERVICE IN FRANCE Coreactivityperformed:…………………………………..……………………………………………………………………………………………………. Addresse(es),(worksite,firm):…………………………………..…………………………………………………………………………………………… Startdate:…………………………………………………………….…Expecteddate:…………………………………………………………….……… (2) (2) Workdaystarttime …………………………………………….Workdayendtime :……………………………………………………………… (2) Numberofrestdayperweek :……………………………………………………………………………………………………………………………… UseofdangerousequipmentorprocessesONOOYES(pleasespecify):…………………………………………………………. ……………………………………………………………………………………………………………………………………………………………………………… SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES FORM:SECONDMENTSTATEMENT 2/2 Whenusingforeignlabourbyaserviceprovider 5 - SECONDED(3) EMPLOYEES (list may be continued on a separate sheet if necessary) N° 1 2 3 Lastname Firstname Dateofbirth Nationality EmploymentContractdate (4) Incountryoforigin Professional qualification JobheldinFrance Grossmonthlysalary (5) inFrance(€) 4 5 6 7 8 9 10 N° 1 2 3 4 5 6 7 8 9 10 Collectiveaccommodationaddress:………………………………………………………………………………………………………………………… Mandatory Corporate Seal Date,filersignature: (1) AnemployerwhohasnotfiledastatementwiththeLabourInspectoratemaybesubjecttoafineprovidedforthirdclassmisdemeanours. InFrance,atleastonedayofrestperweekmustbegranted(aweekbeingunderstoodasfromMondayatmidnightuntilSundayat11:59p.m.). Themaximumworkingweekis48hoursperweekand10hoursperday.Thereisabreakbetweenthestartandendofworkeachdayandabreakis mandatoryafter6hoursofeffectivecontinuouswork. (3) TheemployermustspecifytheidentityofallemployeestobesecondedinFrance,whethertheyareEuropeanUnionnationalsorfromanon-EU country (4) SecondedworkersinFrancemustbeemployedbeforesecondment. (5) Pleaserememberthattheminimumhourlyrateis€9.67grossperhourasof1January2016. (2) SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES WORKPERMITFORM-Forasecondmentlastinglessthan threemonthsforforeignemployees FORM TO COMPLETE & SEND BEFORE 15TH SEPTEMBER 2016 TO: WITHTHEITEMSANDTABLESATTACHEDINFRENCH,BYREGISTEREDLETTER DIRECCTE-1,avenueYouriGagarine-93000BOBIGNY-14èmesection Tel:+33(0)141605324-Fax:+33(0)141602297 Email:[email protected] Companyname:............................................................................................................................................................. Address:…………………………………………………………………………………………………………………….……………………………………………. Postcode:………………….City/Town:…………………………………………………………Country:..…………………………………………….. Tel.:……………………………………Fax:………………..………………Cellphone:………………………………………………………….……………. Email:……………………………………………………………………………..………………………………………………………………………………………. EMPLOYER’S HANDWRITTEN REQUEST Or, where appropriate, by a person established in France dulyauthorizedtoperformadministrativeproceduresinhis name and on his behalf presenting the reasons for the secondmentandthetypeofjobsperformedinFrancebythe secondedemployee(s). ITEMS TO ATTACH, DRAFTED IN FRENCH 1. One copy of CERFA [French Administrative Form Registration and Revision Centre] form no.13647*01 “Request for a Work Permit for a Seconded Employee (excludingintra-groupmobility)”dulycompleted(itmaybe downloaded from www.immigration.gouv.fr); do not attach appendices1,2,or3listedbythedocument. 2. Alettersignedbythesecondedemployee,statingthathe agreestoleaveFrancewhenhisjobiscomplete. 3. A copy of the seconded employee’s passport (identificationandvaliditypages). This procedure is not applicable to employees who are EuropeanUnionorEuropeanEconomicArea(EEA)nationals, or to foreign – non-EU citizen – employees who are legally employed by a firm established in the EU, as the latter are notsubjecttoaworkpermit. The exempt countries are as follows: Germany, Austria, Belgium, Bulgaria, Cyprus, Denmark, Spain, Finland, France, Greece, Ireland, Italy, Luxemburg, Malta,TheNetherlands,Portugal,UnitedKingdom,Sweden, Estonia, Hungary, Latvia, Lithuania, Poland , Slovakia, Slovenia, Romania, Czech Republic, Iceland, Liechtenstein, Norway,Switzerland,Andorra,Monaco,andSanMarino. Mandatory Corporate Seal Asecondmentcertificateintheemployee’snameorasworn affidavit regarding an application for registration with the French Social Security (in the second case, Social Security registration shall be established through the Bas Rhin URSSAF [Social Security Contribution Collection Office] located at 16,rueContades, 67307SchiltigheimCedex.Tel.:+33(0)388185244- Fax:+33(0)369323008– E-mail:[email protected] Website:www.strasbourg.urssaf.fr 5. Ifathirdpartyisauthorizedbytheemployerestablished abroad to submit the work permit request to the administration, the original of the employer’s letter authorizing this person; the authorized person must be capable of providing the requested information and documents. Date, filer signature: SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES REFOUND OFFRENCHVAT(TVA) 1/2 PLEASE FIND IN YOUR EXHIBITOR AREA • ToprinttheVATrefundform,seenextpage To receive further information about the refund claim and the refund procedure, Exhibitors cancontactdirectlyourFrenchTaxRepresentative, TEVEA INTERNATIONAL ClaudiaPRAMS 29-31,rueSaintAugustin–75002Paris–France Tel:+33(0)142249696-Fax:+33(0)142248923 E-mail:[email protected]:www.tevea-international.com Siret:33127028000067 TEVEAInternationalisspecializedinhandlingTVArefundclaimsandwilltakecareoftheentire procedureuntilpaymentofyourrefundedamount.Theprocedurewillbesimpleandeasyfor yourcompany. TEVEA International, in cooperation with the SILMO, offers a simplified, secure and fast procedureforyourcompany. To benefit from this simplification, please fill in, sign and return the form available in your ExhibitorAreatoTEVEAInternational. IMPORTANT: • OnlyoriginalinvoicesareacceptedbytaxauthoritiesforVATrefunds,sokeeptheminasafe place.Ifyoulosethem,youwillnotbeabletoreclaimtheVATamountinquestion. • Copies,duplicatesandcertifiedcopieswillberefusedbytheFrenchTaxAuthorities.Itisalso prohibitedfortheorganizertomakeasecondoriginaloftheinvoice. FOREIGN SERVICE PROVIDERS WORKING FOR EXHIBITORS Standconstructioncontractors,lessorsofequipmentrentalagencies,decorators,etc.cannot takeadvantageofthisprocedure.ServicesundertakeninFrancearesubjecttotheFrenchVAT. TheseforeignserviceprovidersmustinvoicetheirclientswiththeFrenchVATandpaytheVAT collectedthroughtheFrenchtaxrepresentativeintermediarytotheTaxAuthority,deduction madefortheVATonpurchases. SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE BACKTOTHECONTENTS FORMALITIES REFOUND OFFRENCHVAT(TVA) 2/2 According to European Tax Legislation, organisers of international exhibitions may invoice certainserviceswithTVA. Foreign companies (EU or non-EU) are, under certain conditions, entitled to a refund of the TVApaid. IMPORTANT Please note: CompaniesnotbelongingtotheEuropeanUnionmustappointaFrenchtax representativeinordertoapplyforataxrefund. Formoreinformationontherefundclaimsandprocedures,exhibitorscancontactourFrench TaxRepresentative,TEVEAINTERNATIONAL(seereplycouponbelow). TEVEAInternationalspecialisesinthehandlingofTVArefundclaims,andwilltakecareofthe entireprocedureonbehalfofyourcompany. ____________________________________________________________________________ FAX REPLY FORM – PLEASE RETURN TO: TEVEA INTERNATIONAL 29-31rueSaintAugustin–75002Paris-FRANCE Tel:+33(0)142249696–Fax:+33(0)142248923– Email:[email protected] WeareattendingthefollowingFrenchtradeshow: SILMO 2016 from 23rd to 26th September 2016 – Paris Nord-Villepinte. Paris. Please send us all information and documents concerning your TVA refund claim in the followinglanguages: r FRENCH r ENGLISH r GERMAN r ITALIAN r SPANISH Companyname:………………………………………………………………………………………………………………………. Address:………………………………………………………………………………………………………………………………….. Postcode:………………………..City:……………………………………Country:…………………………………………. Tel:…………………………….Fax:…………………………….Email:………………………………………………………….. Contact name: Date and signature: SILMOPARIS2016-23>26SEPTEMBER2016–PARISNORD-VILLEPINTE 70,avenueduGénéraldeGaulle–72058ParislaDéfenseCedex-France SASaucapitalde60000000€-316780519RCSNanterre Sociétémandataired’intermédiaired’assurancen°10058581ORIAS(www.orias.fr) LasociétéComexposiumestsoumiseauContrôlePrudentiel(ACP)