Air conditioning solutions
Transcription
Air conditioning solutions
C0002-06_GEN06 2006 Air conditioning solutions Residential and Light Commercial Systems SOLUTIONS FOR A FRESHER WORLD ™ INDEX INVERTER SPEED SYSTEMS 42PQV_S 42HQV 42PQV_lc 42VQV 40KQV 40DQV 38VYX 38VGM 18 - 19 20 - 21 22 - 23 24 - 25 26 - 27 28 - 29 30 - 31 32 - 33 FIXED SPEED SYSTEM 42PHQ_S 42PHQ_A 42VMC_N 40KMC_N 40SMC_N 40DMC FB4X 38GLM/YYM 34 - 35 36 - 37 38 - 39 40 - 41 42 - 43 44 - 45 46 - 47 48 - 53 DX CONTROLS DX CONTROLS 54 - 55 FIXED SPEED SYSTEM 42HQE 56 - 57 ROOM AIR CONDITIONERS 73FC/XC/YC 51AKA/B/C 51AKS 54DHS 58 - 59 60 - 61 62 - 63 64 - 65 Our mission is to make he world a better place to live. A For our commitment in developing products for a safer, mission that was born more than one hundred years ago cleaner and less polluted planet we received the presti- when Willis Carrier invented the basics of modern air con- gious ditioning and developed the first air conditioning system. Environmental Protection Agency (EPA). Every day around Since then we have created a confortable, productive and the world a Carrier system is installed every eight healthy environment, regardless of climate, and we have seconds, and we are now the world’s largest manufacturer ensured that the global food supply is transported and of air conditioning, ventilation, heating and commercial preserved for safe consumption. refrigeration system. Our dedication to enhance our environment also means preserving the environment for everybody. Carrier was the first air conditioning manufacturer to use chlorine-free refrigerants that do not deplete the ozone layer. SOLUTIONS FOR A FRESHER WORLD Ozone Protection Award from the U.S. Carrier is a member of the United Technologies Corporation (UTC) which employs 205,700 people, operates in more than 180 countries, and is the 51st largest corporation in the United States. The UTC group is a global technology corporation with a long history of a pioneering innovation in aerospace, aviaton, helicopter design, climate control, elevator design and hydrogen fuel cells. Supported by leadership of UTC, Carrier is a source of ideas, technologies and innovation to help buid a better world. CARRIER EXPE RIENCE BACKED BY A LARGE GROUP The world's largest manu- The experts in electronic The world's largest manu- The innovators in hydro- facturer of air conditio- security systems, fire pro- facturer gen-powered fuel cells for ning, ventilation and refri- tection systems and secu- escalators geration systems rity system monitoring walkways of elevators, and moving space, commercial transport and applications. The leading supplier The specialists in com- The world leader inthe of aerospace systemsand mercial and military air- design and manufacture of components, fueand spe- craft engines and space helicopters for commer- cial fluid pumps, and pro- propulsion systems cial, industrial and milita- pellerand engine control systems ry use. residential Carrier is a member of the United Technologies Corporation (UTC) which employs 205,700 people, operates in more than 180 countries, and is the 51st largest corporation in the United States. The UTC group is a global technology corporation with a long history of a pioneering innovation in aerospace, aviaton, helicopter design, climate control, elevator design and hydrogen fuel cells. Supported by leadership of UTC, Carrier is a source of ideas, technologies and innovation to help buid a better world. CARRIER EXPE RIENCE BACKED BY A LARGE GROUP The world's largest manu- The experts in electronic The world's largest manu- The innovators in hydro- facturer of air conditio- security systems, fire pro- facturer gen-powered fuel cells for ning, ventilation and refri- tection systems and secu- escalators geration systems rity system monitoring walkways of elevators, and moving space, commercial transport and applications. The leading supplier The specialists in com- The world leader inthe of aerospace systemsand mercial and military air- design and manufacture of components, fueand spe- craft engines and space helicopters for commer- cial fluid pumps, and pro- propulsion systems cial, industrial and milita- pellerand engine control systems ry use. residential Michelangelo's frescos, the Alexandrian manuscripts and the works of art in the British Museum can be admired thanks to Carrier. Carrier air and climate quality control systems are chosen to protect the most prestigious buildings in the world, supported by the know-how and expertise of a company with over 100 years of experience and continuous innovation. The Carrier brand is renowned as a reliable partner for any application. YOUR PARTNER FOR GREAT CHALLENGES Alexandria Library Suntek City Singapore Carrier has supplied the climate control system that protects New British Museum London The world biggest telescope. Cerro La Silla - Chile and monitors the Sistine Chapel 24 hours a day. Queen Mary II Epcot Center Florida Michelangelo's frescos, the Alexandrian manuscripts and the works of art in the British Museum can be admired thanks to Carrier. Carrier air and climate quality control systems are chosen to protect the most prestigious buildings in the world, supported by the know-how and expertise of a company with over 100 years of experience and continuous innovation. The Carrier brand is renowned as a reliable partner for any application. YOUR PARTNER FOR GREAT CHALLENGES Alexandria Library Suntek City Singapore Carrier has supplied the climate control system that protects New British Museum London The world biggest telescope. Cerro La Silla - Chile and monitors the Sistine Chapel 24 hours a day. Queen Mary II Epcot Center Florida Carrier is the largest organisation world-wide committed to development and research in air conditioning. A great innovative force that continuously sets new standards in comfort, efficiency and installation flexibility. Satellite, the innovatiSatellite detail V-shaped coil ve Carrier ductable system that has completely revolutionised previous market standards, that were of course also set by Carrier. Designed together by the best professionals, and destined to become the absolute new industry standard. RESEARCH + EXPE RIENCE = INNOVATIVE SOLUTION The technical experts unveil a new standard of working - simple, clean, flexible, efficient - leaving customers completely satisfied Carrier is the largest organisation world-wide committed to development and research in air conditioning. A great innovative force that continuously sets new standards in comfort, efficiency and installation flexibility. Satellite, the innovatiSatellite detail V-shaped coil ve Carrier ductable system that has completely revolutionised previous market standards, that were of course also set by Carrier. Designed together by the best professionals, and destined to become the absolute new industry standard. RESEARCH + EXPE RIENCE = INNOVATIVE SOLUTION The technical experts unveil a new standard of working - simple, clean, flexible, efficient - leaving customers completely satisfied The air quality in closed rooms can be 10 times more polluted than the outdoor air. To offer more breathable air, Carrier has developed Air4Life, an efficient four-stage air filtration system, based on titanium-dioxide technology to make the air cleaner and healthier. To recreate the same pleasant sensation of well-being that exists near a waterfall or in a forest in your own home, Carrier air conditioners include ionisers, to make the air more pleasant and healthier to breathe. HEALTHY AIR FOR ENHANCED WELL-BEING The exclusive four-stage Air4Life filtration system makes the The same pleasant sensation of well-being that can be Negative ions assist the elimination of serotonin from the air healthier and cleaner, significantly reducing pollutants, found in a forest or in the mountains can now be achieved blood, providing vigour and energy and increasing concen- pollen and in your own home with the Carrier ioniser. It enriches the tration. With their relaxing effect they are a valuable aid air with negative ions to provide vitality and energy. against daily stress. allergens. The air quality in closed rooms can be 10 times more polluted than the outdoor air. To offer more breathable air, Carrier has developed Air4Life, an efficient four-stage air filtration system, based on titanium-dioxide technology to make the air cleaner and healthier. To recreate the same pleasant sensation of well-being that exists near a waterfall or in a forest in your own home, Carrier air conditioners include ionisers, to make the air more pleasant and healthier to breathe. HEALTHY AIR FOR ENHANCED WELL-BEING The exclusive four-stage Air4Life filtration system makes the The same pleasant sensation of well-being that can be Negative ions assist the elimination of serotonin from the air healthier and cleaner, significantly reducing pollutants, found in a forest or in the mountains can now be achieved blood, providing vigour and energy and increasing concen- pollen and in your own home with the Carrier ioniser. It enriches the tration. With their relaxing effect they are a valuable aid air with negative ions to provide vitality and energy. against daily stress. allergens. Carrier quality and reliability are incorporated and guaranteed in all products and systems. They are submitted to extensive tests before they are shipped to the customers, such as a 10-minute system operating test. They are also certified by the major international organisations to guarantee authenticity of the information supplied, safety of the products and high process applications standards. All this means that the customer will receive a safe and reliable product. RELIABILITY INCLUDED Performance Eurovent guarantee Safety for the customer ISO 9001:2000 process certification Carrier has participated in the Eurovent certification program- In addition to the CE marking, the absolute safety of All Carrier processes are certified in accordance me from the very beginning. Eurovent tests the products and Carrier products is certified and guaranteed by the presti- with the quality management system standard ISO verifies the conformance between test results and product. gious independent performance data published by the 9001:2000 to assure the customer that products manufacturer. and services conform with the policies of the Carrier organisation organisations. IMQ agency or other equivalent Carrier quality and reliability are incorporated and guaranteed in all products and systems. They are submitted to extensive tests before they are shipped to the customers, such as a 10-minute system operating test. They are also certified by the major international organisations to guarantee authenticity of the information supplied, safety of the products and high process applications standards. All this means that the customer will receive a safe and reliable product. RELIABILITY INCLUDED Performance Eurovent guarantee Safety for the customer ISO 9001:2000 process certification Carrier has participated in the Eurovent certification program- In addition to the CE marking, the absolute safety of All Carrier processes are certified in accordance me from the very beginning. Eurovent tests the products and Carrier products is certified and guaranteed by the presti- with the quality management system standard ISO verifies the conformance between test results and product. gious independent performance data published by the 9001:2000 to assure the customer that products manufacturer. and services conform with the policies of the Carrier organisation organisations. IMQ agency or other equivalent Today potential and existing residential and light commercial air conditioning customers are very demanding. They have many differing expectations and varying profiles. The Carrier product range will provide them all with the ideal solution for their individual functional, aesthetic and economical requirements and their personal preference. They will all have the peaceof-mind of having chosen the world's leading industry expert. Carrier has a differentiated product range that also benefits our partners who can now personalise their offer for their own customer base. PERSONALIZED “Absolute well-being” AIR CONDITIONING “Superior comfort” “Comfort at close hand” Today potential and existing residential and light commercial air conditioning customers are very demanding. They have many differing expectations and varying profiles. The Carrier product range will provide them all with the ideal solution for their individual functional, aesthetic and economical requirements and their personal preference. They will all have the peaceof-mind of having chosen the world's leading industry expert. Carrier has a differentiated product range that also benefits our partners who can now personalise their offer for their own customer base. PERSONALIZED “Absolute well-being” AIR CONDITIONING “Superior comfort” “Comfort at close hand” 42PQV_S - HI-WALL UNIT INVERTER SPLIT SYSTEM Indoor unit 42PQV009S 42PQV012S Outdoor unit (HP) 38VBH009S 38VBH012S Nominal cooling capacity kW 2,60 3,50 Minimum cooling capacity kW 1,40 1,80 Maximum cooling capacity kW 3,30 4,00 Nominal power input W 810 1163 Minimum power input W 420 537 Maximum power input W 1467 1818 W/W 3,21 3,01 EER Energy efficiency class (CO) A B Annual energy consumption kWh 405 582 Nominal heating capacity kW 3,20 4,00 Minimum heating capacity kW 1,50 1,90 Maximum heating capacity kW 4,0 5,1 Nominal power input W 928 1246 Minimum power input W 395 506 Maximum power input W 1550 2100 W/W 3,45 3,21 B C COP Energy efficiency class (HP) Indoor unit Dehumidification Air flow (l/m/h) 09 12 l/h 1,1 1,3 l/s 114/135/155 124/141/161 Sound pressure (l/m/h) dB(A)* 33/36/39 35/37/40 Sound power (l/m/h) dB(A) 46/49/52 48/50/53 Dimensions (HxLxD) mm 260x790x196 260x790x196 Weight kg 8,6 8,6 V-ph-Hz 220/240-1-50/60 220/240-1-50/60 Power Supply Outdoor unit (HP) 09 12 Compressor Type rotary rotary Maximum pipe length m 10 15 Maximum height difference m 8 10 Chargeless pipe length Air flow Sound pressure Sound power m 10 15 m3/h 605 - 1690 580 - 1550 dB(A)** 41 41 dB(A) 61 61 Dimensions (HxLxD) mm 590 x 750 x 280 590 x 750 x 280 Weight kg 33 37 inch 3/8 - 1/4 1/2 - 1/4 A 7 11 V-ph-Hz 220/240-1-50/60 220/240-1-50/60 Flare Connections Starting current Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4m. 42PQV_S INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40PQV_S 42PQV_S Inverter hi-wall Class A efficiency - the ultimate evolution of comfort with maximised savings thanks to the XPower inverter technology. 42PQV_S - HI-WALL UNIT The elegant slim-line XPower Sensat-ion will create a feeling of optimal well-being and vitality and blend with any room decoration. CONTROLS 2 sizes in cooling only and heat pump capacities from: 2,6kW to 3,5kW in cooling; 3,2kW to 4,0kW in heating. FEATURES Extra Power, Ionizer and Eco function A perfect combination of ions and micro-filtered air. This way the air in your home is always clean and energised. The start-up speed of the XPower system provides you with maximum comfort in half the time compared to traditional systems. Constant comfort. As the temperature approaches the preset level, XPower gradually reduces the compressor speed. All Sensat-ion models are in Satin finish aluminium, high quality and un-matched style. ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter. EXCLUSIVE 4 STAGE FILTRATION SYSTEM. 1.anti-bacteria pre filter; 2.electrostatic filter; 3.photo catalyst re-generable filter;4.anti-bacteria fan and drain pan. Thanks to the new air management system and to the Inverter technology the noise is reduced to a whisper. OUTDOOR UNITS ANTI CORROSION PROTECTION. Plastic case condensing unit; compact and light. UV light resistant. Monosplit: 38VBH_S 18 19 42PQV_S - HI-WALL UNIT INVERTER SPLIT SYSTEM Indoor unit 42PQV009S 42PQV012S Outdoor unit (HP) 38VBH009S 38VBH012S Nominal cooling capacity kW 2,60 3,50 Minimum cooling capacity kW 1,40 1,80 Maximum cooling capacity kW 3,30 4,00 Nominal power input W 810 1163 Minimum power input W 420 537 Maximum power input W 1467 1818 W/W 3,21 3,01 EER Energy efficiency class (CO) A B Annual energy consumption kWh 405 582 Nominal heating capacity kW 3,20 4,00 Minimum heating capacity kW 1,50 1,90 Maximum heating capacity kW 4,0 5,1 Nominal power input W 928 1246 Minimum power input W 395 506 Maximum power input W 1550 2100 W/W 3,45 3,21 B C COP Energy efficiency class (HP) Indoor unit Dehumidification Air flow (l/m/h) 09 12 l/h 1,1 1,3 l/s 114/135/155 124/141/161 Sound pressure (l/m/h) dB(A)* 33/36/39 35/37/40 Sound power (l/m/h) dB(A) 46/49/52 48/50/53 Dimensions (HxLxD) mm 260x790x196 260x790x196 Weight kg 8,6 8,6 V-ph-Hz 220/240-1-50/60 220/240-1-50/60 Power Supply Outdoor unit (HP) 09 12 Compressor Type rotary rotary Maximum pipe length m 10 15 Maximum height difference m 8 10 Chargeless pipe length Air flow Sound pressure Sound power m 10 15 m3/h 605 - 1690 580 - 1550 dB(A)** 41 41 dB(A) 61 61 Dimensions (HxLxD) mm 590 x 750 x 280 590 x 750 x 280 Weight kg 33 37 inch 3/8 - 1/4 1/2 - 1/4 A 7 11 V-ph-Hz 220/240-1-50/60 220/240-1-50/60 Flare Connections Starting current Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4m. 42PQV_S INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40PQV_S 42PQV_S Inverter hi-wall Class A efficiency - the ultimate evolution of comfort with maximised savings thanks to the XPower inverter technology. 42PQV_S - HI-WALL UNIT The elegant slim-line XPower Sensat-ion will create a feeling of optimal well-being and vitality and blend with any room decoration. CONTROLS 2 sizes in cooling only and heat pump capacities from: 2,6kW to 3,5kW in cooling; 3,2kW to 4,0kW in heating. FEATURES Extra Power, Ionizer and Eco function A perfect combination of ions and micro-filtered air. This way the air in your home is always clean and energised. The start-up speed of the XPower system provides you with maximum comfort in half the time compared to traditional systems. Constant comfort. As the temperature approaches the preset level, XPower gradually reduces the compressor speed. All Sensat-ion models are in Satin finish aluminium, high quality and un-matched style. ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter. EXCLUSIVE 4 STAGE FILTRATION SYSTEM. 1.anti-bacteria pre filter; 2.electrostatic filter; 3.photo catalyst re-generable filter;4.anti-bacteria fan and drain pan. Thanks to the new air management system and to the Inverter technology the noise is reduced to a whisper. OUTDOOR UNITS ANTI CORROSION PROTECTION. Plastic case condensing unit; compact and light. UV light resistant. Monosplit: 38VBH_S 18 19 42HQV_R - HI-WALL UNITS INVERTER SPLIT SYSTEM Indoor unit 42HQV025R 42HQV035R 42HQV045R Outdoor unit HP 38VYX025R 38VYX035R 38VYX045R Nominal cooling capacity kW 2,50 3,50 4,62 Minimum cooling capacity kW 0,90 1,10 1,20 Maximum cooling capacity kW 3,00 4,00 5,10 Nominal power input W 780 1090 1630 Minimum power input W 260 200 260 Maximum power input W 990 1330 1930 3,21 3,21 2,83 A A C EER Energy efficiency class (CO) Annual energy consumption kWh 390 545 815 Nominal heating capacity kW 3,20 4,20 5,90 Minimum heating capacity kW 0,90 1,10 1,30 Maximum heating capacity kW 4,00 5,80 7,40 Nominal power input W 870 1150 1760 Minimum power input W 210 200 270 Maximum power input W 1160 1670 2360 3,68 3,65 3,35 A A C COP Energy efficiency class (HP) Indoor unit Deumidification Air flow (l/m/h) 25 35 45 l/h 1,5 2,0 2,1 l/s 95/125/147 95/125/147 145/179/212 Sound pressure level (l/m/h) dB(A)* 29/35/39 28/34/39 34/40/45 Sound power level (l/m/h) dB(A) 42/48/52 41/47/52 47/53/58 Dimensions (H x L x D) mm 275 x 790 x 208 275 x 790 x 208 275 x 790 x 208 Weight kg 10 10 10 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 25 35 45 Maximum pipe length m 10 15 15 Vertical height difference m Power Supply Outdoor unit (HP) 8 10 10 Rotary Rotary Twin Rrotary m 10 15 15 dB(A)** 40 43 44 Compressor Type Chargeless Sound pressure level (l/m/h) Sound power level (l/m/h) dB(A) 60 63 64 Dimensions (H x L x D) mm 530 x 660 x 240 550 x 780 x 270 550 x 780 x 270 Weight kg 30 36 39 Flare Connections Power Supply * ** inch 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4" V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 Sound Pressure level at 1,5m distance from indoor unit. Sound Pressure level at 1m distance from outdoor unit. The Nano Technology Nano technology increases the filtering capacity, improving the performance of the filters, by reducing the normal filter components size into nano-size or crystal forms. This process makes Nano filters more effective than standard ones. 42HQV_R INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 42HQV_R 42HQV_R DC Inverter Hi-wall A efficiency class in cooling and heating thanks to the advanced XPower DC Inverter technology. 42HQV_R - HIGH-WALL SilenTECH is the ultimate evolution of comfort with its low noise level and its maximum energy savings. 3 sizes heat pump; capacities from 2,5kW to 4,62kW in cooling and from 3,2 kW to 5,9 kW in heating. FEATURES The new XPower DC Inverter technology allows to reach quickly the optimal well-being with the maximum energy savings. Unique combined action of PAM and PWM control. CONTROLS Exclusive air purification system: the new Nano-Photo Copper and the new Nano-Silver-Gingsen filters are the most powerful solution to eliminate bacteria and deodorize the air. Thanks to the XPower DC Inverter technology the sound is light like a feather. The start-up speed of the XPower system provides the maximum comfort in half the time compared to a traditional system. Unique combined action of PAM & PWM controls: - PAM (Pulse Amplitude Modulation) generates maximum power at start-up - PWM (Pulse Width Modulation) optimises the efficiency once the ideal tem perature has been reached. Extra power & Eco function OUTDOOR UNITS The ancient benefits of Gingseng Ginseng is known to lower cholesterol, to balance the metabolism, to increase energy levels, and to stimulate the immune system. It is also used to alleviate fatigue and to reduce stress on the body. It increases cells and tissues oxygenation, promoting detoxification and stimulating the regeneration of damaged cells. Monosplit: 38VYX_R 20 21 42HQV_R - HI-WALL UNITS INVERTER SPLIT SYSTEM Indoor unit 42HQV025R 42HQV035R 42HQV045R Outdoor unit HP 38VYX025R 38VYX035R 38VYX045R Nominal cooling capacity kW 2,50 3,50 4,62 Minimum cooling capacity kW 0,90 1,10 1,20 Maximum cooling capacity kW 3,00 4,00 5,10 Nominal power input W 780 1090 1630 Minimum power input W 260 200 260 Maximum power input W 990 1330 1930 3,21 3,21 2,83 A A C EER Energy efficiency class (CO) Annual energy consumption kWh 390 545 815 Nominal heating capacity kW 3,20 4,20 5,90 Minimum heating capacity kW 0,90 1,10 1,30 Maximum heating capacity kW 4,00 5,80 7,40 Nominal power input W 870 1150 1760 Minimum power input W 210 200 270 Maximum power input W 1160 1670 2360 3,68 3,65 3,35 A A C COP Energy efficiency class (HP) Indoor unit Deumidification Air flow (l/m/h) 25 35 45 l/h 1,5 2,0 2,1 l/s 95/125/147 95/125/147 145/179/212 Sound pressure level (l/m/h) dB(A)* 29/35/39 28/34/39 34/40/45 Sound power level (l/m/h) dB(A) 42/48/52 41/47/52 47/53/58 Dimensions (H x L x D) mm 275 x 790 x 208 275 x 790 x 208 275 x 790 x 208 Weight kg 10 10 10 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 25 35 45 Maximum pipe length m 10 15 15 Vertical height difference m Power Supply Outdoor unit (HP) 8 10 10 Rotary Rotary Twin Rrotary m 10 15 15 dB(A)** 40 43 44 Compressor Type Chargeless Sound pressure level (l/m/h) Sound power level (l/m/h) dB(A) 60 63 64 Dimensions (H x L x D) mm 530 x 660 x 240 550 x 780 x 270 550 x 780 x 270 Weight kg 30 36 39 Flare Connections Power Supply * ** inch 3/8" - 1/4" 3/8" - 1/4" 1/2" - 1/4" V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 Sound Pressure level at 1,5m distance from indoor unit. Sound Pressure level at 1m distance from outdoor unit. The Nano Technology Nano technology increases the filtering capacity, improving the performance of the filters, by reducing the normal filter components size into nano-size or crystal forms. This process makes Nano filters more effective than standard ones. 42HQV_R INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 42HQV_R 42HQV_R DC Inverter Hi-wall A efficiency class in cooling and heating thanks to the advanced XPower DC Inverter technology. 42HQV_R - HIGH-WALL SilenTECH is the ultimate evolution of comfort with its low noise level and its maximum energy savings. 3 sizes heat pump; capacities from 2,5kW to 4,62kW in cooling and from 3,2 kW to 5,9 kW in heating. FEATURES The new XPower DC Inverter technology allows to reach quickly the optimal well-being with the maximum energy savings. Unique combined action of PAM and PWM control. CONTROLS Exclusive air purification system: the new Nano-Photo Copper and the new Nano-Silver-Gingsen filters are the most powerful solution to eliminate bacteria and deodorize the air. Thanks to the XPower DC Inverter technology the sound is light like a feather. The start-up speed of the XPower system provides the maximum comfort in half the time compared to a traditional system. Unique combined action of PAM & PWM controls: - PAM (Pulse Amplitude Modulation) generates maximum power at start-up - PWM (Pulse Width Modulation) optimises the efficiency once the ideal tem perature has been reached. Extra power & Eco function OUTDOOR UNITS The ancient benefits of Gingseng Ginseng is known to lower cholesterol, to balance the metabolism, to increase energy levels, and to stimulate the immune system. It is also used to alleviate fatigue and to reduce stress on the body. It increases cells and tissues oxygenation, promoting detoxification and stimulating the regeneration of damaged cells. Monosplit: 38VYX_R 20 21 42PQV_S LC - HI-WALL UNIT INVERTER SPLIT SYSTEM Indoor unit 42PQV050S 42PQV080S 42PQV110S Outdoor unit HP 38VYX050N 38VYX080N 38VYX110N 9,20 Nominal cooling capacity kW 4,80 6,50 Minimum cooling capacity kW 1,00 2,10 2,20 Maximum cooling capacity kW 5,25 7,00 11,00 W 1780 2490 3333 W/W 2,70 2,61 2,76 D D D kW 890 1245 1667 Nominal power input EER Energy efficiency class (CO) Annual energy consumption EER 50% W/W (1) 4,30 4,20 4,80 Nominal heating capacity kW 5,25 7,60 10,10 Minimum heating capacity kW 0,90 1,70 2,20 Maximum heating capacity kW 6,50 7,94 12,5 Nominal power input W 1540 2750 2962 W/W 3,41 2,76 3,41 B E B 5,20 4,00 5,10 050 080 110 COP Energy efficiency class (HP) COP 50% W/W (1) Indoor unit Deumidification l/h 1,8 2,0 2,1 Nominal air flow (low/med/high) l/s 160/200/230 95/125/147 145/179/212 Sound pressure (low/med/high) (CO) dB(A)* 36/40/43 28/34/39 34/40/45 Sound power (low/med/high) (CO) dB(A) 49/53/56 41/47/52 47/53/58 Sound pressure (low/med/high) (HP) dB(A)* 34/38/41 275 x 790 x 208 275 x 790 x 208 Sound power (low/med/high) (HP) dB(A) 47/51/54 10 10 Dimensions (H x L x D) mm 285x1080x200 285x1080x200 446x546x356 Weight kg 14 14 23 V-Ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 Power supply Outdoor unit (HP) 050 080 110 Compressor Type Twin Rotary Twin Rotary Twin Rotary Maximum pipe lenght m 30 50 50 Maximum height difference m 30 30 (15) 30 (15) Chargeless pipe lenght m 20 20 20 m3/h 290/665 290/110 nd/2085 dB(A)** 43 45 51 Air Flow (Min/Max) Sound pressure (CO) Sound power (CO) dB(A) 63 65 71 dB(A)** 45 47 51 dB(A) 65 67 71 Dimensions (H x L x D) mm 595x780x270 795x900x320 1340x900x320 Weight kg 35 55 75 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” Sound pressure (HP) Sound power (HP) Flare connections Starting current Power supply A 12 15 22 V-Ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 42PQV_S LC INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40PQV_S LC 42PQV_S LC - HI-WALL UNIT DC Blended Inverter Technology: more comfort and effective cost savings. 42PQV_S LC - HI-WALL UNIT Xpower Sensation light commercial high-wall indoor unit offers optimised comfort with an excellent seasonal energy efficiency ratio. In addition Air4Life and the ionizer provide superior indoor air quality. CONTROLS 3 sizes in cooling only and heat pump capacities from: 1,7 kW to 11 kW in cooling; 1,5 kW to 11,5 kW in heating. FEATURES Extra Power, Ionizer and Eco function Customised air distribution - six different air flow positions and exclusive Twin Swing air distribution function. Stable indoor comfort and extremely low room temperature fluctuation. Continuous low-speed operation and compressor sound blankets ensure exceptionally low noise levels for superior acoustic comfort. Stylish and compact with pleasant white flat panel aesthetic for easy integration into any room interiors. ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter. Powerful dehumidification ensures humidity level control during all seasons. A perfect combination of ionised and micro-filtered air for a clean and healthy indoor environment. OUTDOOR UNITS monosplit 38VYX_N 22 23 42PQV_S LC - HI-WALL UNIT INVERTER SPLIT SYSTEM Indoor unit 42PQV050S 42PQV080S 42PQV110S Outdoor unit HP 38VYX050N 38VYX080N 38VYX110N 9,20 Nominal cooling capacity kW 4,80 6,50 Minimum cooling capacity kW 1,00 2,10 2,20 Maximum cooling capacity kW 5,25 7,00 11,00 W 1780 2490 3333 W/W 2,70 2,61 2,76 D D D kW 890 1245 1667 Nominal power input EER Energy efficiency class (CO) Annual energy consumption EER 50% W/W (1) 4,30 4,20 4,80 Nominal heating capacity kW 5,25 7,60 10,10 Minimum heating capacity kW 0,90 1,70 2,20 Maximum heating capacity kW 6,50 7,94 12,5 Nominal power input W 1540 2750 2962 W/W 3,41 2,76 3,41 B E B 5,20 4,00 5,10 050 080 110 COP Energy efficiency class (HP) COP 50% W/W (1) Indoor unit Deumidification l/h 1,8 2,0 2,1 Nominal air flow (low/med/high) l/s 160/200/230 95/125/147 145/179/212 Sound pressure (low/med/high) (CO) dB(A)* 36/40/43 28/34/39 34/40/45 Sound power (low/med/high) (CO) dB(A) 49/53/56 41/47/52 47/53/58 Sound pressure (low/med/high) (HP) dB(A)* 34/38/41 275 x 790 x 208 275 x 790 x 208 Sound power (low/med/high) (HP) dB(A) 47/51/54 10 10 Dimensions (H x L x D) mm 285x1080x200 285x1080x200 446x546x356 Weight kg 14 14 23 V-Ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 Power supply Outdoor unit (HP) 050 080 110 Compressor Type Twin Rotary Twin Rotary Twin Rotary Maximum pipe lenght m 30 50 50 Maximum height difference m 30 30 (15) 30 (15) Chargeless pipe lenght m 20 20 20 m3/h 290/665 290/110 nd/2085 dB(A)** 43 45 51 Air Flow (Min/Max) Sound pressure (CO) Sound power (CO) dB(A) 63 65 71 dB(A)** 45 47 51 dB(A) 65 67 71 Dimensions (H x L x D) mm 595x780x270 795x900x320 1340x900x320 Weight kg 35 55 75 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” Sound pressure (HP) Sound power (HP) Flare connections Starting current Power supply A 12 15 22 V-Ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 42PQV_S LC INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40PQV_S LC 42PQV_S LC - HI-WALL UNIT DC Blended Inverter Technology: more comfort and effective cost savings. 42PQV_S LC - HI-WALL UNIT Xpower Sensation light commercial high-wall indoor unit offers optimised comfort with an excellent seasonal energy efficiency ratio. In addition Air4Life and the ionizer provide superior indoor air quality. CONTROLS 3 sizes in cooling only and heat pump capacities from: 1,7 kW to 11 kW in cooling; 1,5 kW to 11,5 kW in heating. FEATURES Extra Power, Ionizer and Eco function Customised air distribution - six different air flow positions and exclusive Twin Swing air distribution function. Stable indoor comfort and extremely low room temperature fluctuation. Continuous low-speed operation and compressor sound blankets ensure exceptionally low noise levels for superior acoustic comfort. Stylish and compact with pleasant white flat panel aesthetic for easy integration into any room interiors. ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter. Powerful dehumidification ensures humidity level control during all seasons. A perfect combination of ionised and micro-filtered air for a clean and healthy indoor environment. OUTDOOR UNITS monosplit 38VYX_N 22 23 42VQV - CONSOLE UNIT INVERTER SPLIT SYSTEM Indoor unit 42VQV0050 42VQV080 42VQV110 42VQV130 Outdoor unit (HP) 38VYX050N 38VYX080N 42VYX080N 42VYX080N 11,72 Nominal cooling capacity kW 4,85 6,5 9,10 Minimum cooling capacity kW 1,5 2,1 2,20 3,00 Maximum cooling capacity kW 5,25 7,2 11,00 13,00 W 1780 2430 3480 4160 W/W 2,72 2,67 2,61 2,70 D D D D 890 1215 1740 2080 Nominal power input EER Energy efficiency class (CO) Annual energy consumption EER 50% kWh W/W (1) 3,9 4,2 4,80 4,30 Nominal heating capacity kW 5,19 7,32 9,60 12,36 Minimum heating capacity kW 1,5 2,2 2,20 3,00 Maximum heating capacity kW 6 7,94 12,50 15,00 W 1770 2600 2990 4530 W/W 2,93 2,82 3,21 2,70 D D C E 4,4 4,5 4,50 4,40 50 80 110 130 Nominal power input COP Energy efficiency class (HP) COP 50% W/W (1) Indoor unit Dehumidification l/h 1,7 2,7 nd nd Air flow (l/m/h) l/s 150/170/205 165/195/220 265/300/330 380/405/445 Sound pressure (CO) dB(A)* 38/41/45 41/44/49 47/50/52 47/49/51 Sound power (CO) dB(A) 49/52/56 52/55/60 58/61/63 58/60/62 Sound pressure (HP) dB(A)* 38/41/45 41/44/49 44/50/52 47/49/51 Sound power (HP) dB(A) 49/52/56 52/55/60 58/61/63 58/60/62 Dimensions (HxLxD) mm 598x1000x200 598x1000x200 625x1200x232 625x1200x232 Weight kg 18 20 27 38 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 Power Supply Outdoor unit (HP) 50 80 110 130 Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe length m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe length m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 Dimensions (HxLxD) mm 595x780x270 795x900x320 795x900x320 795x900x320 Weight kg Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) 35 55 75 85 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” 3/8” - 5/8” A 12 15 22 23 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 Flare Connections Starting current Power Supply 220/240-1-50 SIZE 30 PRELIMINARY DATA * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 42VQV INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 42VQV 42VQV - CONSOLE UNIT Fits under a window sill. Reduced footprint and compact overall dimensions for a wide choice of installation solutions. 42VQV - CONSOLE UNIT The XPower 42VQV console units provide optimised comfort levels with an excellent seasonal energy efficiency ratio. They are slim and stylish and designed for installation on a wall or under the ceiling. CONTROLS 2 sizes in cooling only and heat pump capacities from: 1,5kW to 7,2kW in cooling; 1,5kW to 7,94kW in heating. FEATURES Award from the Italian Association of Industrial Design (ADI). Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0.01 5m. Filter can be washed and regenerated in sunlight. Motorised louvre allows air distribution direction according to individual preferences. MyComfort remote control function memorises the preferred user settings. State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Condensate discharge pump. Piping cover kit. Fits under a window sill. Reduced footprint and compact overall dimensions for a wide choice of installation solutions. All key components are easily accessible through the grille without removing the front panel. OUTDOOR UNITS Monosplit: 38VYX_N 24 25 42VQV - CONSOLE UNIT INVERTER SPLIT SYSTEM Indoor unit 42VQV0050 42VQV080 42VQV110 42VQV130 Outdoor unit (HP) 38VYX050N 38VYX080N 42VYX080N 42VYX080N 11,72 Nominal cooling capacity kW 4,85 6,5 9,10 Minimum cooling capacity kW 1,5 2,1 2,20 3,00 Maximum cooling capacity kW 5,25 7,2 11,00 13,00 W 1780 2430 3480 4160 W/W 2,72 2,67 2,61 2,70 D D D D 890 1215 1740 2080 Nominal power input EER Energy efficiency class (CO) Annual energy consumption EER 50% kWh W/W (1) 3,9 4,2 4,80 4,30 Nominal heating capacity kW 5,19 7,32 9,60 12,36 Minimum heating capacity kW 1,5 2,2 2,20 3,00 Maximum heating capacity kW 6 7,94 12,50 15,00 W 1770 2600 2990 4530 W/W 2,93 2,82 3,21 2,70 D D C E 4,4 4,5 4,50 4,40 50 80 110 130 Nominal power input COP Energy efficiency class (HP) COP 50% W/W (1) Indoor unit Dehumidification l/h 1,7 2,7 nd nd Air flow (l/m/h) l/s 150/170/205 165/195/220 265/300/330 380/405/445 Sound pressure (CO) dB(A)* 38/41/45 41/44/49 47/50/52 47/49/51 Sound power (CO) dB(A) 49/52/56 52/55/60 58/61/63 58/60/62 Sound pressure (HP) dB(A)* 38/41/45 41/44/49 44/50/52 47/49/51 Sound power (HP) dB(A) 49/52/56 52/55/60 58/61/63 58/60/62 Dimensions (HxLxD) mm 598x1000x200 598x1000x200 625x1200x232 625x1200x232 Weight kg 18 20 27 38 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 Power Supply Outdoor unit (HP) 50 80 110 130 Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe length m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe length m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 Dimensions (HxLxD) mm 595x780x270 795x900x320 795x900x320 795x900x320 Weight kg Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) 35 55 75 85 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” 3/8” - 5/8” A 12 15 22 23 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 Flare Connections Starting current Power Supply 220/240-1-50 SIZE 30 PRELIMINARY DATA * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 42VQV INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 42VQV 42VQV - CONSOLE UNIT Fits under a window sill. Reduced footprint and compact overall dimensions for a wide choice of installation solutions. 42VQV - CONSOLE UNIT The XPower 42VQV console units provide optimised comfort levels with an excellent seasonal energy efficiency ratio. They are slim and stylish and designed for installation on a wall or under the ceiling. CONTROLS 2 sizes in cooling only and heat pump capacities from: 1,5kW to 7,2kW in cooling; 1,5kW to 7,94kW in heating. FEATURES Award from the Italian Association of Industrial Design (ADI). Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0.01 5m. Filter can be washed and regenerated in sunlight. Motorised louvre allows air distribution direction according to individual preferences. MyComfort remote control function memorises the preferred user settings. State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Condensate discharge pump. Piping cover kit. Fits under a window sill. Reduced footprint and compact overall dimensions for a wide choice of installation solutions. All key components are easily accessible through the grille without removing the front panel. OUTDOOR UNITS Monosplit: 38VYX_N 24 25 40KQV - CASSETTE UNIT INVERTER SPLIT SYSTEM Indoor unit 40KQV050 40KQV080 40KQV110 40KQV130 Outdoor unit (HP) 38VYX050N 38VYX080N 38VYX110N 38VYX130N 12,40 Nominal cooling capacity kW 4,85 6,60 10,30 Minimum cooling capacity kW 1,50 2,20 2,20 3,00 Maximum cooling capacity kW 5,25 7,90 11,50 13,50 W 1830 2350 3610 4350 W/W 2,65 2,81 2,85 2,85 D C C na kWh 915 1175 1805 - W/W (1) 4,00 4,50 4,00 3,50 Nominal heating capacity kW 5,07 7,55 10,10 13,00 Minimum heating capacity kW 1,50 2,2 2,2 3 Maximum heating capacity kW 6,00 9 12 15 W 1550 2350 3150 4050 W/W 3,27 3,21 3,21 3,21 C C C na W/W (1) 4,10 4,50 4,50 4,40 50 80 110 130 l/h 1,7 1,8 3,7 4,5 Nominal power input EER Energy efficiency class (CO) Annual energy consumption EER 50% Nominal power input COP Energy efficiency class (HP) COP 50% Indoor unit Dehumidification Air flow (l/m/h) l/s 190/210/250 200/250/300 320/385/455 420/465/525 Sound pressure (CO) dB(A)* 38/42/45 32/36/39 37/42/45 42/46/48 Sound power (CO) dB(A) 51/55/58 45/49/52 50/55/58 55/59/61 Sound pressure (HP) dB(A)* 38/42/45 31/34/37 37/42/45 42/46/48 Sound power (HP) dB(A) 51/55/58 44/47/50 50/55/58 55/59/61 Dimensions (HxLxD) mm 298x575x575 298x825x825 298x825x825 298x825x825 Weight mm 19 38 38 38 Grille Dimensions(HxLxD) mm 30x720x720 30x960x960 30x960x960 30x960x960 Grille weight kg 3,1 6,5 6,5 6,5 Outdoor unit (HP) 50 80 110 130 Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe length m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe length m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 Dimensions (HxLxD) mm 595x780x270 795x900x320 795x900x320 795x900x320 Weight kg 35 55 75 85 Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) Flare Connections Starting current Power Supply 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 A 12 15 22 23 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 40KQV INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40KQV 40KQV Powerful filtration system with photo-catalytic titanium filters and high-efficiency electrostatic filters. 40KQV - CASSETTE UNIT The XPower 40KQV cassettes provide optimised comfort levels with an excellent seasonal energy efficiency ratio. They received a design awarded from the Italian Association of Industrial Design and are the ideal choice for commercial applications. CONTROLS 4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,5kW in cooling; 1,5kW to 15,0 kW in heating FEATURES Simply opening the grille gives access to all critical components. Freedom of choice between infrared remote control and wired controls. Fresh air intake and additional outlet grille allow air conditioning of an adjoining room. Fresh air inlet for constant air renewal. Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0.01 5m and high-efficiency electrostatic filters. Two, three and four-way motorised louvres allow air flow direction according to individual preferences. ACCESSORIES Air supply outlet obstruction kit Stable indoor comfort with extremely low indoor temperature fluctuation. OUTDOOR UNITS Monosplit: 38VYX_N 26 27 40KQV - CASSETTE UNIT INVERTER SPLIT SYSTEM Indoor unit 40KQV050 40KQV080 40KQV110 40KQV130 Outdoor unit (HP) 38VYX050N 38VYX080N 38VYX110N 38VYX130N 12,40 Nominal cooling capacity kW 4,85 6,60 10,30 Minimum cooling capacity kW 1,50 2,20 2,20 3,00 Maximum cooling capacity kW 5,25 7,90 11,50 13,50 W 1830 2350 3610 4350 W/W 2,65 2,81 2,85 2,85 D C C na kWh 915 1175 1805 - W/W (1) 4,00 4,50 4,00 3,50 Nominal heating capacity kW 5,07 7,55 10,10 13,00 Minimum heating capacity kW 1,50 2,2 2,2 3 Maximum heating capacity kW 6,00 9 12 15 W 1550 2350 3150 4050 W/W 3,27 3,21 3,21 3,21 C C C na W/W (1) 4,10 4,50 4,50 4,40 50 80 110 130 l/h 1,7 1,8 3,7 4,5 Nominal power input EER Energy efficiency class (CO) Annual energy consumption EER 50% Nominal power input COP Energy efficiency class (HP) COP 50% Indoor unit Dehumidification Air flow (l/m/h) l/s 190/210/250 200/250/300 320/385/455 420/465/525 Sound pressure (CO) dB(A)* 38/42/45 32/36/39 37/42/45 42/46/48 Sound power (CO) dB(A) 51/55/58 45/49/52 50/55/58 55/59/61 Sound pressure (HP) dB(A)* 38/42/45 31/34/37 37/42/45 42/46/48 Sound power (HP) dB(A) 51/55/58 44/47/50 50/55/58 55/59/61 Dimensions (HxLxD) mm 298x575x575 298x825x825 298x825x825 298x825x825 Weight mm 19 38 38 38 Grille Dimensions(HxLxD) mm 30x720x720 30x960x960 30x960x960 30x960x960 Grille weight kg 3,1 6,5 6,5 6,5 Outdoor unit (HP) 50 80 110 130 Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe length m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe length m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 Dimensions (HxLxD) mm 595x780x270 795x900x320 795x900x320 795x900x320 Weight kg 35 55 75 85 Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) Flare Connections Starting current Power Supply 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 A 12 15 22 23 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 40KQV INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40KQV 40KQV Powerful filtration system with photo-catalytic titanium filters and high-efficiency electrostatic filters. 40KQV - CASSETTE UNIT The XPower 40KQV cassettes provide optimised comfort levels with an excellent seasonal energy efficiency ratio. They received a design awarded from the Italian Association of Industrial Design and are the ideal choice for commercial applications. CONTROLS 4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,5kW in cooling; 1,5kW to 15,0 kW in heating FEATURES Simply opening the grille gives access to all critical components. Freedom of choice between infrared remote control and wired controls. Fresh air intake and additional outlet grille allow air conditioning of an adjoining room. Fresh air inlet for constant air renewal. Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0.01 5m and high-efficiency electrostatic filters. Two, three and four-way motorised louvres allow air flow direction according to individual preferences. ACCESSORIES Air supply outlet obstruction kit Stable indoor comfort with extremely low indoor temperature fluctuation. OUTDOOR UNITS Monosplit: 38VYX_N 26 27 40DQV - SATELLITE UNITS INVERTER SPLIT SYSTEM Indoor units 40DQV050 40DQV080 40DQV110 40DQV130 Outdoor units 38VYX050N 38VYX080N 38VYX110N 38VYX130N 12,40 Nominal cooling capacity kW 5,00 6,70 10,00 Minimum cooling capacity kW 1,50 2,10 2,20 3,00 Maximum cooling capacity kW 5,25 7,20 11,50 13,00 W 1910 2500 3430 4500 W/W 2,62 2,68 2,92 2,76 D D C ns kWh 955 1250 1715 – W/W (1) 4,30 4,30 4,80 4,30 Nominal heating capacity kW 5,00 2,00 11,10 13,50 Minimum heating capacity kW 1,50 2,00 2,20 3,00 Maximum heating capacity kW 6,00 8,80 12,50 15,00 Nominal power input W 1430 2600 3210 3850 COP / Energy, efficiency class W/W 3,50 2,96 3,46 3,45 Energy efficiency class W/W B D B na W/W (1) 4,80 4,80 5,10 4,80 050 080 110 130 Nominal power input EER Energy efficiency class Annual Energy Consuption (CO) EER 50% COP 50% Indoor unit Dehumidification l/h 1,6 2 3,1 3,8 Air flow (low/med/high) l/s 210/263/294 205/211/269 291/380/463 390/476/564 Nominal static pressure Pa 50 50 80 80 Sound Pressure (low/med/high) (CO) dB(A) 39/40/42 38/40/42 44/46/49 46/49/52 Sound Power (low/med/high) (CO) dB(A) 52/53/55 51/53/55 57/59/62 59/62/65 Sound Pressure (low/med/high) (HP) dB(A) 39/40/42 38/40/42 44/46/49 46/49/52 Sound Power (low/med/high) (HP) dB(A) 52/53/55 51/53/55 57/59/62 59/62/65 Dimensions mm 925x750x285 925x750x285 1325x750x285 1325x750x285 Weight kg 32 35 48 48 050 080 110 130 Outdoor unit Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe lenght m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe lenght Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) Dimensions (HxLxD) Weight Flare Connections Starting current Power Supply m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 mm 595x780x270 795x900x320 795x900x320 795x900x320 kg 35 55 75 85 inch 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” 3/8” - 5/8” A 12 15 22 23 V-ph-Hz 220-240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 285 40DQV INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40DQV 40DQV Ultra-slim profile - only 285 mm for all sizes, thanks to the Carrier-patented V-shaped coil. 40DQV - SATELLITE UNITS The new ducted above-ceiling XPower units from Carrier represent a breakthrough in design terms. They provide best level of comfort with an excellent seasonal energy efficiency ratio. The slimmest profile ever and flexible installation options make this unit the best choice for homes and light commercial premises. CONTROLS 4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,0kW in cooling; 1,5kW to 15,0 kW in heating. FEATURES Freedom of choice between infrared remote control and wired controls. Designed for front or side air discharge. Unique design with lateral air discharge allows the unit to be installed in a corridor. Modular filter and panel sizes allow flexible unit mounting with rear or bottom air return. Equipped with pre-punched 150-mm diameter fresh air intakes on both sides, and with pre-punched Octopus discharge panel. ACCESSORIES MyComfort infrared control kit. Control box equipped with 1.5-m cable for flexible positioning and accessibility. OUTDOOR UNITS Monosplit: 38VYX_N 28 29 40DQV - SATELLITE UNITS INVERTER SPLIT SYSTEM Indoor units 40DQV050 40DQV080 40DQV110 40DQV130 Outdoor units 38VYX050N 38VYX080N 38VYX110N 38VYX130N 12,40 Nominal cooling capacity kW 5,00 6,70 10,00 Minimum cooling capacity kW 1,50 2,10 2,20 3,00 Maximum cooling capacity kW 5,25 7,20 11,50 13,00 W 1910 2500 3430 4500 W/W 2,62 2,68 2,92 2,76 D D C ns kWh 955 1250 1715 – W/W (1) 4,30 4,30 4,80 4,30 Nominal heating capacity kW 5,00 2,00 11,10 13,50 Minimum heating capacity kW 1,50 2,00 2,20 3,00 Maximum heating capacity kW 6,00 8,80 12,50 15,00 Nominal power input W 1430 2600 3210 3850 COP / Energy, efficiency class W/W 3,50 2,96 3,46 3,45 Energy efficiency class W/W B D B na W/W (1) 4,80 4,80 5,10 4,80 050 080 110 130 Nominal power input EER Energy efficiency class Annual Energy Consuption (CO) EER 50% COP 50% Indoor unit Dehumidification l/h 1,6 2 3,1 3,8 Air flow (low/med/high) l/s 210/263/294 205/211/269 291/380/463 390/476/564 Nominal static pressure Pa 50 50 80 80 Sound Pressure (low/med/high) (CO) dB(A) 39/40/42 38/40/42 44/46/49 46/49/52 Sound Power (low/med/high) (CO) dB(A) 52/53/55 51/53/55 57/59/62 59/62/65 Sound Pressure (low/med/high) (HP) dB(A) 39/40/42 38/40/42 44/46/49 46/49/52 Sound Power (low/med/high) (HP) dB(A) 52/53/55 51/53/55 57/59/62 59/62/65 Dimensions mm 925x750x285 925x750x285 1325x750x285 1325x750x285 Weight kg 32 35 48 48 050 080 110 130 Outdoor unit Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe lenght m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe lenght Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) Dimensions (HxLxD) Weight Flare Connections Starting current Power Supply m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 mm 595x780x270 795x900x320 795x900x320 795x900x320 kg 35 55 75 85 inch 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” 3/8” - 5/8” A 12 15 22 23 V-ph-Hz 220-240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 (1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity 285 40DQV INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 40DQV 40DQV Ultra-slim profile - only 285 mm for all sizes, thanks to the Carrier-patented V-shaped coil. 40DQV - SATELLITE UNITS The new ducted above-ceiling XPower units from Carrier represent a breakthrough in design terms. They provide best level of comfort with an excellent seasonal energy efficiency ratio. The slimmest profile ever and flexible installation options make this unit the best choice for homes and light commercial premises. CONTROLS 4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,0kW in cooling; 1,5kW to 15,0 kW in heating. FEATURES Freedom of choice between infrared remote control and wired controls. Designed for front or side air discharge. Unique design with lateral air discharge allows the unit to be installed in a corridor. Modular filter and panel sizes allow flexible unit mounting with rear or bottom air return. Equipped with pre-punched 150-mm diameter fresh air intakes on both sides, and with pre-punched Octopus discharge panel. ACCESSORIES MyComfort infrared control kit. Control box equipped with 1.5-m cable for flexible positioning and accessibility. OUTDOOR UNITS Monosplit: 38VYX_N 28 29 38VYX_N - CONDENSING UNITS Outdoor unit (HP) 38VYX50N 38VYX080N 38VYX110N 38VYX130N Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe length m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe length m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 mm 595x780x270 795x900x320 795x900x320 795x900x320 Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) Dimensions (HxLxD) Weight Flare Connections Starting current Power Supply kg 35 55 75 85 inch 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” 3/8” - 5/8” A 12 15 22 23 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 38VYX_N INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 38VYX_N INVERTER SPLIT SYSTEM ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 Twin rotary compressor to reduce vibration and noise and to provide superior efficiency performance. OPERATING LIMITS Cooling mode Heating mode 38VYX_N maximum conditions outdoor temperature 43°C. indoor temperature 32°C dry bulb / 23°C wet bulb. minimum conditions outdoor temperature -5°C (080, 110, 130); -15°C (050). indoor temperature 21°C dry bulb / 15°C wet bulb. maximum conditions outdoor temperature 24°C dry bulb / 18°C wet bulb. indoor temperature 27°C dry bulb. minimum conditions outdoor temperature -15°C dry bulb. 38VYX_N - CONDENSING UNITS CONTROLS 4 sizes in cooling only and heat pump. FEATURES Freedom of choice between infrared remote control and wired controls. Systems can operate at -5°C in cooling mode and -15°C in heating mode. Outdoor and outdoor fan speeds are electronically fine tuned to deliver the needed air flow reach the best performance. INDOOR UNITS No current peaks: Start-up current absorption is always lower than operating current value. Advanced self-diagnosis tool for an automatic complete system check-up and for maintenance routine monitoring. Designed for challenging installations. Up to 50 m in distance and 30 m in elevation; chargeless up to 20 m. 42PQV_S lc The pulse modulation valve (PVM) regulates the refrigerant flow in the circuit. 42VQV 40KQV 40DQV 30 31 38VYX_N - CONDENSING UNITS Outdoor unit (HP) 38VYX50N 38VYX080N 38VYX110N 38VYX130N Compressor Type Twin rotary Twin rotary Twin rotary Twin rotary Maximum pipe length m 30 50 50 50 Maximum height difference m 30 30 30 30 Chargeless pipe length m 20 20 20 20 m3/h 290/665 290/1110 nd/1890 nd/2085 dB(A)** 43 45 51 51 dB(A) 63 65 71 71 dB(A)** 45 47 51 51 dB(A) 65 67 71 71 mm 595x780x270 795x900x320 795x900x320 795x900x320 Air flow (Min/Max) Sound pressure (CO) Sound power (CO) Sound pressure (HP) Sound power (HP) Dimensions (HxLxD) Weight Flare Connections Starting current Power Supply kg 35 55 75 85 inch 1/4” - 1/2” 3/8” - 5/8” 3/8” - 5/8” 3/8” - 5/8” A 12 15 22 23 V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 38VYX_N INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 38VYX_N INVERTER SPLIT SYSTEM ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 Twin rotary compressor to reduce vibration and noise and to provide superior efficiency performance. OPERATING LIMITS Cooling mode Heating mode 38VYX_N maximum conditions outdoor temperature 43°C. indoor temperature 32°C dry bulb / 23°C wet bulb. minimum conditions outdoor temperature -5°C (080, 110, 130); -15°C (050). indoor temperature 21°C dry bulb / 15°C wet bulb. maximum conditions outdoor temperature 24°C dry bulb / 18°C wet bulb. indoor temperature 27°C dry bulb. minimum conditions outdoor temperature -15°C dry bulb. 38VYX_N - CONDENSING UNITS CONTROLS 4 sizes in cooling only and heat pump. FEATURES Freedom of choice between infrared remote control and wired controls. Systems can operate at -5°C in cooling mode and -15°C in heating mode. Outdoor and outdoor fan speeds are electronically fine tuned to deliver the needed air flow reach the best performance. INDOOR UNITS No current peaks: Start-up current absorption is always lower than operating current value. Advanced self-diagnosis tool for an automatic complete system check-up and for maintenance routine monitoring. Designed for challenging installations. Up to 50 m in distance and 30 m in elevation; chargeless up to 20 m. 42PQV_S lc The pulse modulation valve (PVM) regulates the refrigerant flow in the circuit. 42VQV 40KQV 40DQV 30 31 38VGM_N/VYM_N - MULTI-SPLIT CONDENSING UNIT INVERTER SPLIT SYSTEM 38VYM-14N 38VYM-18N 38VYM-28N N. of compressors Model HP 1 1 1 1 Compressor type Twin Rotary Twin Rotary Twin Rotary Twin Rotary 38VYM-32N Refrigerant charge g 900 1150 2400 2400 Maximum pipe lenght per unit m 20 20 25 25 Mimimum pipe lenght per unit m (4) 2(5) 2(5) 2 2 Maximum height difference m 10 10 15 15 Total pipe lenght m 30 30 50 70 Total chargless pipe lenght m 30 30 50 70 1 1 2 2 dB (A) 43 43 48 48 Min. no. of connected indoor units Sound pressure (CO) Sound power (CO) dB (A) 63 63 68 68 dB (A) (2) 44 44 48 48 dB (A) 64 64 68 68 Air flow (min./nominal/max) l/s 344/539/656 344/539/656 383/656/689 383/656/689 Dimensions (H x L x D) mm 590x800x300 590x800x300 800x800x300 800x800x300 Weight kg 46 50 65 65 n° x (in) (3) 2x(1/4”) - 2x(3/8”) 2x(1/4”) - 2x(3/8”) 3x(1/4”) - 3x(3/8”) 4x(1/4”) - 4x(3/8”) A (5) 11,5 11,5 14,2 14,2 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 Sound pressure (HP) Sound power (HP) Flare Connections Maximum running current Power supply 38VGM_N/VYM_N INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 38VGM_N/VYM_N 38VGM_N/VYM_N Inverter Multi Condensing Unit DC Blended Inverter Technology – the sophisticated electronics system maximises performance and inverter savings. PRELIMINARY DATA 38VGM_N/VYM_N 38VGM-14N 38VGM-18N 38VGM-18N N. of compressors Model CO 1 1 1 1 Compressor type Twin Rotary Twin Rotary Twin Rotary Twin Rotary 900 1150 2400 2400 25 Refrigerant charge g 38VGM-32N Maximum pipe lenght per unit m 20 20 25 Mimimum pipe lenght per unit m (4) 2 (5) 2 (5) 2 2 Maximum height difference m 10 10 15 15 Total pipe lenght m 30 30 50 70 Total chargless pipe lenght m 30 30 50 70 1 1 2 2 dB(A) (2) 43 43 48 48 dB (A) 63 63 68 68 Air flow (min./nominal/max) l/s 344/539/656 344/539/656 383/656/689 383/656/689 Dimensions (H x L x D) mm 590x800x300 590x800x300 800x800x300 800x800x300 Weight kg 46 50 65 65 n° x 2x(1/4”) - 2x(3/8”) 2x(1/4”) - 2x(3/8”) 3x(1/4”) - 3x(3/8”) 4x(1/4”) - 4x(3/8”) Min. no. of connected indoor units Sound pressure (CO) Sound power (CO) Flare Connections Maximum running current Power supply 2) Sound pressure level in emispheric field at 4 m 3) Connecting pipes for PQM015 and SQM015 must be 1/4" - 1/2" Flare adapter to be mounted on outdoor unit will be supplied together with indoor unit 4) 5 meters with one unit connected. 5) Variable speed compressor can reduce this value during operation. 11,5 11,5 14,2 14,2 230-1-50 230-1-50 230-1-50 230-1-50 PRELIMINARY DATA CONTROLS 38VGM_N/VYM_N is the Carrier inverter multi-split outdoor unit. Carrier's inverter multisplit range multiplies the XPower advantages, so several rooms can be air conditioned at low cost. 4 sizes in cooling only and heat pump. FEATURES Suitable for long-distance pipes: a single condensing unit can be connected up to four hi-walls mounted in different areas of the house. Self-diagnosis system: counting on 40 different check codes, the diagnostic process is extremely precise and effective. Electronic modulation valves regulate the refrigerant flow and optimise the cooling temperature in the refrigeration circuit. Modular control system ACCESSORIES/OPTIONS Wall brackets INDOOR UNITS The provided refrigerant charge fits any combination; systems don't require any additional charge, making installations easier and faster. Corrosion-resistant base and cabinet, made UV-resistant polymer materials. 42PQM_S 40SQM 32 33 38VGM_N/VYM_N - MULTI-SPLIT CONDENSING UNIT INVERTER SPLIT SYSTEM 38VYM-14N 38VYM-18N 38VYM-28N N. of compressors Model HP 1 1 1 1 Compressor type Twin Rotary Twin Rotary Twin Rotary Twin Rotary 38VYM-32N Refrigerant charge g 900 1150 2400 2400 Maximum pipe lenght per unit m 20 20 25 25 Mimimum pipe lenght per unit m (4) 2(5) 2(5) 2 2 Maximum height difference m 10 10 15 15 Total pipe lenght m 30 30 50 70 Total chargless pipe lenght m 30 30 50 70 1 1 2 2 dB (A) 43 43 48 48 Min. no. of connected indoor units Sound pressure (CO) Sound power (CO) dB (A) 63 63 68 68 dB (A) (2) 44 44 48 48 dB (A) 64 64 68 68 Air flow (min./nominal/max) l/s 344/539/656 344/539/656 383/656/689 383/656/689 Dimensions (H x L x D) mm 590x800x300 590x800x300 800x800x300 800x800x300 Weight kg 46 50 65 65 n° x (in) (3) 2x(1/4”) - 2x(3/8”) 2x(1/4”) - 2x(3/8”) 3x(1/4”) - 3x(3/8”) 4x(1/4”) - 4x(3/8”) A (5) 11,5 11,5 14,2 14,2 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 Sound pressure (HP) Sound power (HP) Flare Connections Maximum running current Power supply 38VGM_N/VYM_N INVERTER SPLIT SYSTEM INVERTER SPLIT SYSTEM 38VGM_N/VYM_N 38VGM_N/VYM_N Inverter Multi Condensing Unit DC Blended Inverter Technology – the sophisticated electronics system maximises performance and inverter savings. PRELIMINARY DATA 38VGM_N/VYM_N 38VGM-14N 38VGM-18N 38VGM-18N N. of compressors Model CO 1 1 1 1 Compressor type Twin Rotary Twin Rotary Twin Rotary Twin Rotary 900 1150 2400 2400 25 Refrigerant charge g 38VGM-32N Maximum pipe lenght per unit m 20 20 25 Mimimum pipe lenght per unit m (4) 2 (5) 2 (5) 2 2 Maximum height difference m 10 10 15 15 Total pipe lenght m 30 30 50 70 Total chargless pipe lenght m 30 30 50 70 1 1 2 2 dB(A) (2) 43 43 48 48 dB (A) 63 63 68 68 Air flow (min./nominal/max) l/s 344/539/656 344/539/656 383/656/689 383/656/689 Dimensions (H x L x D) mm 590x800x300 590x800x300 800x800x300 800x800x300 Weight kg 46 50 65 65 n° x 2x(1/4”) - 2x(3/8”) 2x(1/4”) - 2x(3/8”) 3x(1/4”) - 3x(3/8”) 4x(1/4”) - 4x(3/8”) Min. no. of connected indoor units Sound pressure (CO) Sound power (CO) Flare Connections Maximum running current Power supply 2) Sound pressure level in emispheric field at 4 m 3) Connecting pipes for PQM015 and SQM015 must be 1/4" - 1/2" Flare adapter to be mounted on outdoor unit will be supplied together with indoor unit 4) 5 meters with one unit connected. 5) Variable speed compressor can reduce this value during operation. 11,5 11,5 14,2 14,2 230-1-50 230-1-50 230-1-50 230-1-50 PRELIMINARY DATA CONTROLS 38VGM_N/VYM_N is the Carrier inverter multi-split outdoor unit. Carrier's inverter multisplit range multiplies the XPower advantages, so several rooms can be air conditioned at low cost. 4 sizes in cooling only and heat pump. FEATURES Suitable for long-distance pipes: a single condensing unit can be connected up to four hi-walls mounted in different areas of the house. Self-diagnosis system: counting on 40 different check codes, the diagnostic process is extremely precise and effective. Electronic modulation valves regulate the refrigerant flow and optimise the cooling temperature in the refrigeration circuit. Modular control system ACCESSORIES/OPTIONS Wall brackets INDOOR UNITS The provided refrigerant charge fits any combination; systems don't require any additional charge, making installations easier and faster. Corrosion-resistant base and cabinet, made UV-resistant polymer materials. 42PQM_S 40SQM 32 33 42PHQ_S - HI-WALL UNIT FIXED SPEED SPLIT SYSTEM Indoor unit 42PHQ009S 42PHQ012S 42PHQ014S 42PHQ018S 42PHQ024S Outdoor unit 38BC-009G 38BC-012G 38BC-014G 38GL-018G 38GL-024G Cooling capacity (CO) kW 2,82 3,43 3,90 5,22 6,03 Power input (CO) W 920 1200 1540 2130 2500 2,41 Energy efficiency class 3,07 2,86 2,53 2,45 EER W/W 460 C E E E Annual energy consumption (CO) kWh B 600 770 1065 1250 38YY-024G Outdoor unit 38BH-009G 38BH-0124 38BH-0144 38YY-018G Cooling capacity (CO) kW 2,75 3,37 3,89 5,02 6,14 Power input (CO) W 840 1120 1480 2010 2510 W/W 3,27 3,01 2,63 2,50 2,45 A B D E E 560 740 1005 1255 EER Energy efficiency class (CO) Annual energy consumption kWh 420 Heating capacity kW 3,07 3,65 4,40 5,59 7,53 Power input (HP) W 880 1190 1490 1960 2680 W/W 3,49 3,07 2,95 2,85 2,81 B D D D D 009 012 014 018 024 COP Energy efficiency class (HP) 42PHQ_S FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42PHQ_S 42PHQ_S - HI-Wall unit Ioniser Function Indoor unit Dehumidification l/h 0,90 1,20 1,46 1,54 2,08 Air flow (l/m/h) l/s 116/132/154 125/143/165 150/168/187 204/223/242 250/275/300 Sound pressure (l/m/h) dB(A)* 30/31/35 32/36/39 39/41/43 39/41/43 43/46/49 Sound power (l/m/h) dB(A) 43/44/48 45/49/52 52/54/56 52/54/57 56/59/62 Dimensions (HxLxD) mm 260x790x196 260x790x196 260x790x196 295x1080x200 295x1080x200 Weight Power Supply kg 8,6 8,6 8,6 14 14 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 009 012 014 018 024 Outdoor unit Compressor Type Rotary Rotary Rotary Rotary Rotary Maximum pipe length m 10 15 15 30 40 Maximum height difference m 5 5 8 15 15 Chargeless m 10 10 10 8 8 dB(A)** 38/38 38/38 40/40 45/46 45/48 dB(A) 58/58 58/58 60/60 65/66 65/68 Dimensions (HxLxD) mm 550x780x270 550x780x270 590x750x280 590x800x300 803x800x300 Weight (CO/HP) kg 30/33 33/36 35/37 45 51/60 Flare Connections A 3/8” - 1/4” 1/2” - 1/4” 1/2” - 1/4” 1/2” - 1/4” 1/2” - 1/4” V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Sound pressure (CO/HP) Sound power (CO/HP) Power Supply * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 42PHQ_S - HI-WALL UNITS Creat-ion recreates the atmosphere of natural environments in your home, providing a sense of well-being and vitality for all the family. CONTROLS 10 sizes in cooling only and heat pump capacities from: 2,82 kW to 6,03 kW in cooling; 2,75 kW to 6,14 kW in heating. FEATURES Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter, regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment. The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being. Customised air distribution - six different air flow positions and exclusive Twin Swing air distribution function. My comfort Remote Control ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter Stylish and compact with pleasant white flat panel aesthetic for easy integration into any room interiors. Programmable timer for easy on and off selection with great energy savings. Creat-ion is felt, but not heard. The indoor unit is extremely quiet to ensure total relaxation. Exclusive, ergonomic and personalised remote control - the unique MyComfort function memorises preferred user settings and ensures easy recall. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YY_M 34 35 42PHQ_S - HI-WALL UNIT FIXED SPEED SPLIT SYSTEM Indoor unit 42PHQ009S 42PHQ012S 42PHQ014S 42PHQ018S 42PHQ024S Outdoor unit 38BC-009G 38BC-012G 38BC-014G 38GL-018G 38GL-024G Cooling capacity (CO) kW 2,82 3,43 3,90 5,22 6,03 Power input (CO) W 920 1200 1540 2130 2500 2,41 Energy efficiency class 3,07 2,86 2,53 2,45 EER W/W 460 C E E E Annual energy consumption (CO) kWh B 600 770 1065 1250 38YY-024G Outdoor unit 38BH-009G 38BH-0124 38BH-0144 38YY-018G Cooling capacity (CO) kW 2,75 3,37 3,89 5,02 6,14 Power input (CO) W 840 1120 1480 2010 2510 W/W 3,27 3,01 2,63 2,50 2,45 A B D E E 560 740 1005 1255 EER Energy efficiency class (CO) Annual energy consumption kWh 420 Heating capacity kW 3,07 3,65 4,40 5,59 7,53 Power input (HP) W 880 1190 1490 1960 2680 W/W 3,49 3,07 2,95 2,85 2,81 B D D D D 009 012 014 018 024 COP Energy efficiency class (HP) 42PHQ_S FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42PHQ_S 42PHQ_S - HI-Wall unit Ioniser Function Indoor unit Dehumidification l/h 0,90 1,20 1,46 1,54 2,08 Air flow (l/m/h) l/s 116/132/154 125/143/165 150/168/187 204/223/242 250/275/300 Sound pressure (l/m/h) dB(A)* 30/31/35 32/36/39 39/41/43 39/41/43 43/46/49 Sound power (l/m/h) dB(A) 43/44/48 45/49/52 52/54/56 52/54/57 56/59/62 Dimensions (HxLxD) mm 260x790x196 260x790x196 260x790x196 295x1080x200 295x1080x200 Weight Power Supply kg 8,6 8,6 8,6 14 14 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 009 012 014 018 024 Outdoor unit Compressor Type Rotary Rotary Rotary Rotary Rotary Maximum pipe length m 10 15 15 30 40 Maximum height difference m 5 5 8 15 15 Chargeless m 10 10 10 8 8 dB(A)** 38/38 38/38 40/40 45/46 45/48 dB(A) 58/58 58/58 60/60 65/66 65/68 Dimensions (HxLxD) mm 550x780x270 550x780x270 590x750x280 590x800x300 803x800x300 Weight (CO/HP) kg 30/33 33/36 35/37 45 51/60 Flare Connections A 3/8” - 1/4” 1/2” - 1/4” 1/2” - 1/4” 1/2” - 1/4” 1/2” - 1/4” V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Sound pressure (CO/HP) Sound power (CO/HP) Power Supply * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 42PHQ_S - HI-WALL UNITS Creat-ion recreates the atmosphere of natural environments in your home, providing a sense of well-being and vitality for all the family. CONTROLS 10 sizes in cooling only and heat pump capacities from: 2,82 kW to 6,03 kW in cooling; 2,75 kW to 6,14 kW in heating. FEATURES Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter, regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment. The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being. Customised air distribution - six different air flow positions and exclusive Twin Swing air distribution function. My comfort Remote Control ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter Stylish and compact with pleasant white flat panel aesthetic for easy integration into any room interiors. Programmable timer for easy on and off selection with great energy savings. Creat-ion is felt, but not heard. The indoor unit is extremely quiet to ensure total relaxation. Exclusive, ergonomic and personalised remote control - the unique MyComfort function memorises preferred user settings and ensures easy recall. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YY_M 34 35 42PHQ_A - HI-WALL UNIT FIXED SPEED SPLIT SYSTEM 42PHQ_A - HI-Wall unit Indoor unit 42PHQ009A 42PHQ012A 38YP-009 38YP-012 Cooling capacity (CO) kW 2,75 3,50 Power input (CO) W 856 1090 W/W 3,21 3,21 EER Energy efficiency class (CO) A A 545 Annual energy consumption kWh 428 Heating capacity kW 3,07 3,80 Power input (HP) W 850 1052 W/W 3,61 3,61 A A 009 012 COP Energy efficiency class (HP) Indoor unit Dehumidification l/h 0,9 1,2 Air flow (l/m/h) l/s 93/118/153 118/132/203 Sound pressure (l/m/h) dB(A)* 27/30/39 41/43/45 Sound power (l/m/h) dB(A) 40/43/52 52/54/56 Dimensions (HxLxD) mm 260x790x196 260x790x196 Weight kg 8,6 8,6 V-ph-Hz 230-1-50 230-1-50 Power Supply Outdoor unit (HP) 009 012 Compressor Type Rotary Rotary Maximum pipe length m 10 15 Maximum height difference m 5 5 Chargeless m 10 10 dB(A)** 40 41 dB(A) 60 61 Dimensions (HxLxD) mm 550x780x270 550x780x270 Weight kg 32 40 Flare Connections A 3/8” - 1/4” 1/2” - 1/4” V-ph-Hz 230-1-50 230-1-50 Sound pressure Sound power Power Supply Class A efficiency in cooling and heating The ultimate evolution of comfort with maximised savings. 42PHQ_A FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42PHQ_A Outdoor unit (HP) 42PHQ_A - HI-WALL UNITS Creat-ion recreates the atmosphere of natural environments in your home, providing a sense of well-being and vitality for all the family. CONTROLS 2 sizes in cooling only and heat pump capacities from: 2,75 kW to 3,50 kW in cooling; 3,07 kW to 3,80 kW in heating. Ionizer function FEATURES Stylish and compact with pleasant white flat panel aesthetic for easy integration into any room interiors. Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter, regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment. * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being. ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter Programmable timer for easy on and off selection with great energy savings; includes a sleep function to automatically manage the right temperature during the night. Exclusive, ergonomic and personalised remote control - the unique MyComfort function memorises preferred user settings and ensures easy recall. OUTDOOR UNITS Monosplit: 38YP 36 37 42PHQ_A - HI-WALL UNIT FIXED SPEED SPLIT SYSTEM 42PHQ_A - HI-Wall unit Indoor unit 42PHQ009A 42PHQ012A 38YP-009 38YP-012 Cooling capacity (CO) kW 2,75 3,50 Power input (CO) W 856 1090 W/W 3,21 3,21 EER Energy efficiency class (CO) A A 545 Annual energy consumption kWh 428 Heating capacity kW 3,07 3,80 Power input (HP) W 850 1052 W/W 3,61 3,61 A A 009 012 COP Energy efficiency class (HP) Indoor unit Dehumidification l/h 0,9 1,2 Air flow (l/m/h) l/s 93/118/153 118/132/203 Sound pressure (l/m/h) dB(A)* 27/30/39 41/43/45 Sound power (l/m/h) dB(A) 40/43/52 52/54/56 Dimensions (HxLxD) mm 260x790x196 260x790x196 Weight kg 8,6 8,6 V-ph-Hz 230-1-50 230-1-50 Power Supply Outdoor unit (HP) 009 012 Compressor Type Rotary Rotary Maximum pipe length m 10 15 Maximum height difference m 5 5 Chargeless m 10 10 dB(A)** 40 41 dB(A) 60 61 Dimensions (HxLxD) mm 550x780x270 550x780x270 Weight kg 32 40 Flare Connections A 3/8” - 1/4” 1/2” - 1/4” V-ph-Hz 230-1-50 230-1-50 Sound pressure Sound power Power Supply Class A efficiency in cooling and heating The ultimate evolution of comfort with maximised savings. 42PHQ_A FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42PHQ_A Outdoor unit (HP) 42PHQ_A - HI-WALL UNITS Creat-ion recreates the atmosphere of natural environments in your home, providing a sense of well-being and vitality for all the family. CONTROLS 2 sizes in cooling only and heat pump capacities from: 2,75 kW to 3,50 kW in cooling; 3,07 kW to 3,80 kW in heating. Ionizer function FEATURES Stylish and compact with pleasant white flat panel aesthetic for easy integration into any room interiors. Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter, regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment. * Sound pressure level in a free field according to JIS9612 Standard ** Sound pressure level in emispheric field at 4 m Performances evaluated with 5m interconnecting tubes and according to EN14511 The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being. ACCESSORIES Filter kit: photo-catalytic and passive electrostatic filter Programmable timer for easy on and off selection with great energy savings; includes a sleep function to automatically manage the right temperature during the night. Exclusive, ergonomic and personalised remote control - the unique MyComfort function memorises preferred user settings and ensures easy recall. OUTDOOR UNITS Monosplit: 38YP 36 37 42VMC_N - CONSOLE UNITS FIXED SPEED SPLIT SYSTEM Indoor unit 42VMC009N 42VMC012N 42VMC014N 42VMC018N 42VMC024N 42VMC028N 42VMC036N 42VMC048N Outdoor unit (CO) 38BC-009G 38BC-012G 38BC-014G 38GL-018G 38GL-024G 38GL-028G9 38GL-036G9 38GL-048G9 Cooling capacity (CO) kW 2,69 3,27 4,47 5,34 6,01 7,6 8,3 10,1 Power input (CO) W 920 1200 1640 2190 2510 2860 3280 3500 W/W 2,92 2,73 2,73 2,44 2,39 2,66 2,53 2,89 C D D E F D E C 460 600 820 1095 1255 1430 1640 1750 38YY-048G9 EER Energy efficiency class (CO) Annual energy consumption kWh Outdoor unit (HP) 38BH-009G 38BH-012G 38BH-014G 38YY-018G 38YY-024G 38YY-028G9 38YY-036G9 Cooling capacity (CO) kW 2,62 3,22 4,35 5,26 6,4 7,3 8,1 10,1 Power input (CO) W 830 1130 1630 2090 2720 3070 3430 3510 W/W 3,16 2,85 2,67 2,52 2,35 2,38 2,36 2,88 B C D E F F F C 565 815 1045 1360 1535 1715 1755 EER Energy efficiency class (CO) Annual energy consumption kWh 415 Heating capacity kW 2,94 3,52 4,75 5,67 6,8 8 8,9 10,9 Power input (HP) W 960 1260 1570 2030 2570 2880 3230 3800 W/W 3,06 2,79 3,03 2,79 2,65 2,78 2,76 2,87 D E D E E E E D 09 12 14 18 24 28 36 48 1 1 - 2,5 2,5 - - - COP Energy efficiency class (HP) Indoor unit Electric heater kW Dehumidification l/h 1,2 1,5 1,7 2 2,2 2,8 3,1 3,6 Air flow (l/m/h) l/s 78/88/100 85/96/114 130/150/170 136/162/199 164/202/249 240/275/302 240/275/302 313/337/364 Sound pressure (l/m/h) dB(A)* 33/36/39 36/38/42 38/39/41 38/41/46 41/44/50 44/48/50 44/48/50 48/50/53 Sound power (l/m/h) dB(A) 44/47/50 47/49/53 49/50/52 49/52/57 52/55/61 55/59/61 55/59/61 59/61/64 Dimensions (HxLxD) mm 540x850x200 540x850x200 Weight Power Supply kg 15 16 18 18 20 35 35 36 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 09 12 14 18 24 28 36 48 8 sizes in cooling only and heat pump capacities from: 2,69kW to 10,10kW in cooling; 2,94kW to 10,9kW in heating. rotary rotary rotary rotary rotary scroll scroll scroll 15 15 15 30 40 40 50 50 Compressor Type Air flow (CO/HP) Sound pressure (CO/HP) Sound power (CO/HP) Dimensions (HxLxD) (CO) m 598x1000x200 598x1000x200 598x1000x200 610x1200x225 610x1200x225 610x1200x225 m 5 5 8 15 15 25 30 30 m 10 10 10 8 8 8 8 8 m3/h 1540 1540 1540 1900/2400 1900/2600 2400 2400/3100 4900/4200 38 / 38 38 / 38 40 / 40 45 / 46 45 / 49 48 / 48 49 / 52 53 / 54 Award from the Italian Association of Industrial Design (ADI). dB(A) 58 / 58 58 / 58 60 / 60 65 / 66 65 / 69 68 / 68 69 / 72 73 / 74 mm 590x750x280 590x750x280 590x750x280 590x800x300 590x800x300 803x800x300 803x800x300 1264x800x300 Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0.01 µm. Filter can be washed and regenerated in sunlight. kg 30 33 35 45 51 65 65 92 Dimensions (HxLxD) (HP) mm 590x750x280 590x750x280 590x750x280 590x800x300 803x800x300 803x800x300 803x800x300 1264x800x300 Flare Connections Starting current Power Supply * ** FEATURES dB(A)** Weight (CO) Weight (HP) 42VMC_N - CONSOLE UNITS Carrier console units are slim and stylish, making many conventional air conditioning units look old-fashioned in comparison. A versatile solution, designed for installation on a wall or under the ceiling. Outdoor unit Maximum pipe length (CO/HP) Maximum height difference (CO/HP) Chargeless pipe length (CO/HP) Stylish design for modern interiors. kg 33 36 37 47 60 67 68 94 inch 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 5/8 - 1/4 3/4 - 3/8 3/4 - 3/8 A 17 24 28 50 56 37 39 54 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 400-3-50 Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. Motorised louvre allows air distribution direction according to individual preferences. MyComfort remote control function memorises the preferred user settings. State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet. 42VMC_N FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42VMC_N 42 VMC-N Console & Underceiling CONTROLS Freedom of choice between infrared remote control and wired controls. ACCESSORIES Condensate discharge pump Hot water coil kit Piping cover kit Electric heater Fits under a window sill. Reduced footprint and compact overall dimensions for a wide choice of installation solutions. All key components are easily accessible through the grille without removing the front panel. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 38 39 42VMC_N - CONSOLE UNITS FIXED SPEED SPLIT SYSTEM Indoor unit 42VMC009N 42VMC012N 42VMC014N 42VMC018N 42VMC024N 42VMC028N 42VMC036N 42VMC048N Outdoor unit (CO) 38BC-009G 38BC-012G 38BC-014G 38GL-018G 38GL-024G 38GL-028G9 38GL-036G9 38GL-048G9 Cooling capacity (CO) kW 2,69 3,27 4,47 5,34 6,01 7,6 8,3 10,1 Power input (CO) W 920 1200 1640 2190 2510 2860 3280 3500 W/W 2,92 2,73 2,73 2,44 2,39 2,66 2,53 2,89 C D D E F D E C 460 600 820 1095 1255 1430 1640 1750 38YY-048G9 EER Energy efficiency class (CO) Annual energy consumption kWh Outdoor unit (HP) 38BH-009G 38BH-012G 38BH-014G 38YY-018G 38YY-024G 38YY-028G9 38YY-036G9 Cooling capacity (CO) kW 2,62 3,22 4,35 5,26 6,4 7,3 8,1 10,1 Power input (CO) W 830 1130 1630 2090 2720 3070 3430 3510 W/W 3,16 2,85 2,67 2,52 2,35 2,38 2,36 2,88 B C D E F F F C 565 815 1045 1360 1535 1715 1755 EER Energy efficiency class (CO) Annual energy consumption kWh 415 Heating capacity kW 2,94 3,52 4,75 5,67 6,8 8 8,9 10,9 Power input (HP) W 960 1260 1570 2030 2570 2880 3230 3800 W/W 3,06 2,79 3,03 2,79 2,65 2,78 2,76 2,87 D E D E E E E D 09 12 14 18 24 28 36 48 1 1 - 2,5 2,5 - - - COP Energy efficiency class (HP) Indoor unit Electric heater kW Dehumidification l/h 1,2 1,5 1,7 2 2,2 2,8 3,1 3,6 Air flow (l/m/h) l/s 78/88/100 85/96/114 130/150/170 136/162/199 164/202/249 240/275/302 240/275/302 313/337/364 Sound pressure (l/m/h) dB(A)* 33/36/39 36/38/42 38/39/41 38/41/46 41/44/50 44/48/50 44/48/50 48/50/53 Sound power (l/m/h) dB(A) 44/47/50 47/49/53 49/50/52 49/52/57 52/55/61 55/59/61 55/59/61 59/61/64 Dimensions (HxLxD) mm 540x850x200 540x850x200 Weight Power Supply kg 15 16 18 18 20 35 35 36 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 09 12 14 18 24 28 36 48 8 sizes in cooling only and heat pump capacities from: 2,69kW to 10,10kW in cooling; 2,94kW to 10,9kW in heating. rotary rotary rotary rotary rotary scroll scroll scroll 15 15 15 30 40 40 50 50 Compressor Type Air flow (CO/HP) Sound pressure (CO/HP) Sound power (CO/HP) Dimensions (HxLxD) (CO) m 598x1000x200 598x1000x200 598x1000x200 610x1200x225 610x1200x225 610x1200x225 m 5 5 8 15 15 25 30 30 m 10 10 10 8 8 8 8 8 m3/h 1540 1540 1540 1900/2400 1900/2600 2400 2400/3100 4900/4200 38 / 38 38 / 38 40 / 40 45 / 46 45 / 49 48 / 48 49 / 52 53 / 54 Award from the Italian Association of Industrial Design (ADI). dB(A) 58 / 58 58 / 58 60 / 60 65 / 66 65 / 69 68 / 68 69 / 72 73 / 74 mm 590x750x280 590x750x280 590x750x280 590x800x300 590x800x300 803x800x300 803x800x300 1264x800x300 Equipped with photo-catalytic titanium filters that remove odours and impurities up to 0.01 µm. Filter can be washed and regenerated in sunlight. kg 30 33 35 45 51 65 65 92 Dimensions (HxLxD) (HP) mm 590x750x280 590x750x280 590x750x280 590x800x300 803x800x300 803x800x300 803x800x300 1264x800x300 Flare Connections Starting current Power Supply * ** FEATURES dB(A)** Weight (CO) Weight (HP) 42VMC_N - CONSOLE UNITS Carrier console units are slim and stylish, making many conventional air conditioning units look old-fashioned in comparison. A versatile solution, designed for installation on a wall or under the ceiling. Outdoor unit Maximum pipe length (CO/HP) Maximum height difference (CO/HP) Chargeless pipe length (CO/HP) Stylish design for modern interiors. kg 33 36 37 47 60 67 68 94 inch 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 5/8 - 1/4 3/4 - 3/8 3/4 - 3/8 A 17 24 28 50 56 37 39 54 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 400-3-50 Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. Motorised louvre allows air distribution direction according to individual preferences. MyComfort remote control function memorises the preferred user settings. State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet. 42VMC_N FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42VMC_N 42 VMC-N Console & Underceiling CONTROLS Freedom of choice between infrared remote control and wired controls. ACCESSORIES Condensate discharge pump Hot water coil kit Piping cover kit Electric heater Fits under a window sill. Reduced footprint and compact overall dimensions for a wide choice of installation solutions. All key components are easily accessible through the grille without removing the front panel. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 38 39 40KMC_N - CASSETTE UNITS FIXED SPEED SPLIT SYSTEM 40KMC-N Cassette Indoor unit 40KMC012-7N 40KMC018-7N 40KMC024-7N 40KMC028-7N 40KMC036-7N 40KMC048-7N 40KMC060-7N 38BC-012G 38GL-018G 38GL-024G 38GL-028G9 38GL-036G9 38GL-048G9 38GL-060G9 Cooling capacity (CO) kW 3,58 5,59 6,1 8,28 9 10,9 13,6 Power input (CO) W 1240 2180 2460 2880 3320 3540 4900 W/W 2,89 2,56 2,48 2,88 2,71 3,08 2,78 C E E C D B na 620 1090 1230 1440 1660 1770 - 12 18 24 28 36 48 60 EER Energy efficiency class (CO) Annual energy consumption kWh Outdoor unit (HP) Cooling capacity (CO) kW 3,52 4,92 6,23 7,86 8,74 10,92 12,4 Power input (CO) W 1160 2000 2790 3100 3470 3540 5220 W/W 3,03 2,46 2,23 2,54 2,52 3,08 2,38 B E F E E B na EER Energy efficiency class (CO) Annual energy consumption kWh 580 1000 1395 1550 1735 1770 - Heating capacity kW 3,78 5,38 7,02 8,03 8,94 10,87 13,24 W 1280 2160 2780 2640 2960 3490 4620 W/W 2,95 2,49 2,53 3,04 3,02 3,11 2,87 D F F D D D na Power input (HP) COP Energy efficiency class (HP) Indoor unit 12 18 24 28 36 48 60 1,5 1,5+1,0 1,5+1,0 2,0+1,0 2,0+1,0 2,0+1,0 2,0+1,0 Electric heater kW Dehumidification l/h 0,8 1,9 2,5 3,0 3,5 4,6 5,2 Air flow (l/m/h) l/s 152/167/183 156/175/194 189/213/250 200/250/300 270/305/350 320/390/460 400/470/515 Sound pressure (l/m/h) dB(A)* 27/31/34 30/33/36 35/38/42 29/32/36 33/36/39 37/42/45 43/46/49 Sound power (l/m/h) dB(A) 40/44/47 43/46/49 48/51/55 42/45/49 46/49/52 50/55/58 56/59/62 Dimensions (HxLxD) mm 298/575/575 298/575/575 298/575/575 298/825/825 298/825/825 298/825/825 298/825/825 Weight kg 17,5 19 19 36,0 38,0 38,0 41 Grille Dimensions(HxLxD) mm 30/720/720 30/720/720 30/720/720 30/960/960 30/960/960 30/960/960 30/960/960 Grille weight kg 2,5 2,5 2,5 5,0 5,0 5,0 5 Power Supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Outdoor unit Compressor Type 12 18 24 28 36 48 60 rotary rotary rotary rotary scroll scroll scroll Maximum pipe length (CO/HP) m 15 30 40 40 50 50 50 Maximum height difference (CO/HP) m 5 15 15 25 30 30 30 Chargeless pipe length (CO/HP) m 10 8 8 8 8 8 8 m3/h 1540 1900/2400 1900/2600 2400 2400/3100 4900/4200 4900/4200 dB(A)** 38 / 38 45 / 46 45 / 49 48 / 48 49 / 52 53 / 54 52 / 53 dB(A) 58 / 58 65 / 66 65 / 69 68 / 68 69 / 72 73 / 74 72 / 73 Dimensions (HxLxD) (CO) mm 590x750x280 590x800x300 590x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 Weight (CO) kg 33 45 51 65 65 92 94 Dimensions (HxLxD) (HP) mm 590x750x280 590x800x300 803x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 Air flow (CO/HP) Sound pressure (CO/HP) Sound power (CO/HP) Weight (HP) Flare Connections Starting current Power Supply * ** kg 36 47 60 67 68 94 96 inch 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 5/8 - 1/4 3/4 - 3/8 3/4 - 3/8 3/4 - 3/8 A 28 50 56 37 39 54 64 V-ph-Hz 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 400-3-50 400-3-50 The patented wing-shaped centrifugal fan, new heat exchanger and improved air management system ensure near-perfect acoustic performance. 40KMC_N FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 40KMC_N Outdoor unit (CO) 40KMC_N - CASSETTE UNITS If you need a system with the right combination of performance, style and flexibility, the Carrier cassette is the natural choice. CONTROLS 7 sizes in cooling only and heat pump capacities from: 3,58kW to 13,6kW in cooling; 3,78kW to 13,24kW in heating. FEATURES Standard dimensions compatible with all suspended ceiling systems in common use in shops and offices. Award from the Italian Association of Industrial Design (ADI). Simply opening the grille gives access to all critical components. Fresh air intake and additional outlet grille allow air conditioning of an adjoining room. Two, three and four-way motorised louvres allow air flow direction according to individual preferences. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Air4Life kit: photo-catalytic titanium and electrostatic filters Air supply outlet obstruction kit Electric heater Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 40 41 40KMC_N - CASSETTE UNITS FIXED SPEED SPLIT SYSTEM 40KMC-N Cassette Indoor unit 40KMC012-7N 40KMC018-7N 40KMC024-7N 40KMC028-7N 40KMC036-7N 40KMC048-7N 40KMC060-7N 38BC-012G 38GL-018G 38GL-024G 38GL-028G9 38GL-036G9 38GL-048G9 38GL-060G9 Cooling capacity (CO) kW 3,58 5,59 6,1 8,28 9 10,9 13,6 Power input (CO) W 1240 2180 2460 2880 3320 3540 4900 W/W 2,89 2,56 2,48 2,88 2,71 3,08 2,78 C E E C D B na 620 1090 1230 1440 1660 1770 - 12 18 24 28 36 48 60 EER Energy efficiency class (CO) Annual energy consumption kWh Outdoor unit (HP) Cooling capacity (CO) kW 3,52 4,92 6,23 7,86 8,74 10,92 12,4 Power input (CO) W 1160 2000 2790 3100 3470 3540 5220 W/W 3,03 2,46 2,23 2,54 2,52 3,08 2,38 B E F E E B na EER Energy efficiency class (CO) Annual energy consumption kWh 580 1000 1395 1550 1735 1770 - Heating capacity kW 3,78 5,38 7,02 8,03 8,94 10,87 13,24 W 1280 2160 2780 2640 2960 3490 4620 W/W 2,95 2,49 2,53 3,04 3,02 3,11 2,87 D F F D D D na Power input (HP) COP Energy efficiency class (HP) Indoor unit 12 18 24 28 36 48 60 1,5 1,5+1,0 1,5+1,0 2,0+1,0 2,0+1,0 2,0+1,0 2,0+1,0 Electric heater kW Dehumidification l/h 0,8 1,9 2,5 3,0 3,5 4,6 5,2 Air flow (l/m/h) l/s 152/167/183 156/175/194 189/213/250 200/250/300 270/305/350 320/390/460 400/470/515 Sound pressure (l/m/h) dB(A)* 27/31/34 30/33/36 35/38/42 29/32/36 33/36/39 37/42/45 43/46/49 Sound power (l/m/h) dB(A) 40/44/47 43/46/49 48/51/55 42/45/49 46/49/52 50/55/58 56/59/62 Dimensions (HxLxD) mm 298/575/575 298/575/575 298/575/575 298/825/825 298/825/825 298/825/825 298/825/825 Weight kg 17,5 19 19 36,0 38,0 38,0 41 Grille Dimensions(HxLxD) mm 30/720/720 30/720/720 30/720/720 30/960/960 30/960/960 30/960/960 30/960/960 Grille weight kg 2,5 2,5 2,5 5,0 5,0 5,0 5 Power Supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Outdoor unit Compressor Type 12 18 24 28 36 48 60 rotary rotary rotary rotary scroll scroll scroll Maximum pipe length (CO/HP) m 15 30 40 40 50 50 50 Maximum height difference (CO/HP) m 5 15 15 25 30 30 30 Chargeless pipe length (CO/HP) m 10 8 8 8 8 8 8 m3/h 1540 1900/2400 1900/2600 2400 2400/3100 4900/4200 4900/4200 dB(A)** 38 / 38 45 / 46 45 / 49 48 / 48 49 / 52 53 / 54 52 / 53 dB(A) 58 / 58 65 / 66 65 / 69 68 / 68 69 / 72 73 / 74 72 / 73 Dimensions (HxLxD) (CO) mm 590x750x280 590x800x300 590x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 Weight (CO) kg 33 45 51 65 65 92 94 Dimensions (HxLxD) (HP) mm 590x750x280 590x800x300 803x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 Air flow (CO/HP) Sound pressure (CO/HP) Sound power (CO/HP) Weight (HP) Flare Connections Starting current Power Supply * ** kg 36 47 60 67 68 94 96 inch 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 5/8 - 1/4 3/4 - 3/8 3/4 - 3/8 3/4 - 3/8 A 28 50 56 37 39 54 64 V-ph-Hz 230-1-50 230-1-50 230-1-50 400-3-50 400-3-50 400-3-50 400-3-50 The patented wing-shaped centrifugal fan, new heat exchanger and improved air management system ensure near-perfect acoustic performance. 40KMC_N FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 40KMC_N Outdoor unit (CO) 40KMC_N - CASSETTE UNITS If you need a system with the right combination of performance, style and flexibility, the Carrier cassette is the natural choice. CONTROLS 7 sizes in cooling only and heat pump capacities from: 3,58kW to 13,6kW in cooling; 3,78kW to 13,24kW in heating. FEATURES Standard dimensions compatible with all suspended ceiling systems in common use in shops and offices. Award from the Italian Association of Industrial Design (ADI). Simply opening the grille gives access to all critical components. Fresh air intake and additional outlet grille allow air conditioning of an adjoining room. Two, three and four-way motorised louvres allow air flow direction according to individual preferences. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Air4Life kit: photo-catalytic titanium and electrostatic filters Air supply outlet obstruction kit Electric heater Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 40 41 40SMC_N - SATELLITE UNITS Indoor unit 40SMC009N 40SMC012N 40SMC018N Outdoor unit (CO) 38BC-009G 38BC-012G 38GL-018G Cooling capacity (CO) kW 2,71 3,41 5,09 Power input (CO) W 1030 1250 2300 W/W 2,63 2,73 2,21 D D F kWh 515 625 1150 09 12 18 kW 2,64 3,35 5,11 W 950 1170 2180 W/W 2,78 2,86 2,34 D C F 475 585 1090 EER Energy efficiency class (CO) Annual energy consumption Outdoor unit (HP) Cooling capacity (CO) Power input (CO) EER Energy efficiency class (CO) Annual energy consumption kWh Heating capacity kW 3,2 3,76 5,44 Power input (HP) W 980 1250 2170 W/W 3,27 3,01 2,51 C D F COP Energy efficiency class (HP) Indoor unit 09 12 18 Dehumidification l/h 0,5 0,8 1,9 Air flow (l/m/h) l/s 92/103/133 103/118/139 126/149/182 Static Pressure Pa 33 40 45 Sound pressure (l/m/h) dB(A)* 42/43/44 42/44/45 43/45/47 Sound power (l/m/h) dB(A) 55/56/57 56/57/58 56/58/60 Dimensions (HxLxD) mm 220x725x555 220x725x555 220x725x555 Weight Power Supply kg 23 23 23 V-ph-Hz 230-1-50 230-1-50 230-1-50 Outdoor unit Compressor Type 09 12 18 rotary rotary rotary Maximum pipe length (CO/HP) m 15 15 30 Maximum height difference (CO/HP) m 5 5 15 Chargeless pipe length (CO/HP) m 10 10 8 Air flow (CO/HP) m3/h 1540 1540 1900/2400 dB(A)** 38 / 38 38 / 38 45 / 46 dB(A) 58 / 58 58 / 58 65 / 66 Dimensions (HxLxD) (CO) mm 590x750x280 590x750x280 590x800x300 Weight (CO) kg 30 33 45 Dimensions (HxLxD) (HP) mm 590x750x280 590x750x280 590x800x300 Sound pressure (CO/HP) Sound power (CO/HP) Weight (HP) Flare Connections Starting current Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. kg 33 36 47 inch 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 A 24 28 50 V-ph-Hz 230-1-50 230-1-50 230-1-50 Installation flexibility with a wide range of accessories. 40SMC_N - SATELLITE UNITS With its compact size and flexibility the Carrier 40SMC ducted system is the ideal choice for both new and refurbished buildings. 40SMC_N FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 40SMC_N FIXED SPEED SPLIT SYSTEM CONTROLS 8 sizes in cooling only and heat pump capacities from: 2,71kW to 13,6kW in cooling; 3,2kW to 14,00kW in heating. FEATURES The preferred solution for consultants and installers - quick and easy to install, compatible with existing electrical and plumbing systems. Ducted system - the ideal choice for both new and refurbished houses. Filters, coils, motors and valves are easily accessible by removing only a few screws. Powerful three-speed direct-drive fan delivers air at up to 80 Pa external static pressure. Unique slim-line profile - the low unit height permits installation even in low ceilings. Compact and 30% lighter than other ducted units on the market. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Electric heater. Hot water coil and anti-freeze thermostat. Mixing box for fresh air. Suction plenum. Discharge plenum. Octopus - two, three or four outlets. High-efficiency gravimetric filter. 3-way, 4-connection valve for hot water coil. MyComfort infrared control kit. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 42 43 40SMC_N - SATELLITE UNITS Indoor unit 40SMC009N 40SMC012N 40SMC018N Outdoor unit (CO) 38BC-009G 38BC-012G 38GL-018G Cooling capacity (CO) kW 2,71 3,41 5,09 Power input (CO) W 1030 1250 2300 W/W 2,63 2,73 2,21 D D F kWh 515 625 1150 09 12 18 kW 2,64 3,35 5,11 W 950 1170 2180 W/W 2,78 2,86 2,34 D C F 475 585 1090 EER Energy efficiency class (CO) Annual energy consumption Outdoor unit (HP) Cooling capacity (CO) Power input (CO) EER Energy efficiency class (CO) Annual energy consumption kWh Heating capacity kW 3,2 3,76 5,44 Power input (HP) W 980 1250 2170 W/W 3,27 3,01 2,51 C D F COP Energy efficiency class (HP) Indoor unit 09 12 18 Dehumidification l/h 0,5 0,8 1,9 Air flow (l/m/h) l/s 92/103/133 103/118/139 126/149/182 Static Pressure Pa 33 40 45 Sound pressure (l/m/h) dB(A)* 42/43/44 42/44/45 43/45/47 Sound power (l/m/h) dB(A) 55/56/57 56/57/58 56/58/60 Dimensions (HxLxD) mm 220x725x555 220x725x555 220x725x555 Weight Power Supply kg 23 23 23 V-ph-Hz 230-1-50 230-1-50 230-1-50 Outdoor unit Compressor Type 09 12 18 rotary rotary rotary Maximum pipe length (CO/HP) m 15 15 30 Maximum height difference (CO/HP) m 5 5 15 Chargeless pipe length (CO/HP) m 10 10 8 Air flow (CO/HP) m3/h 1540 1540 1900/2400 dB(A)** 38 / 38 38 / 38 45 / 46 dB(A) 58 / 58 58 / 58 65 / 66 Dimensions (HxLxD) (CO) mm 590x750x280 590x750x280 590x800x300 Weight (CO) kg 30 33 45 Dimensions (HxLxD) (HP) mm 590x750x280 590x750x280 590x800x300 Sound pressure (CO/HP) Sound power (CO/HP) Weight (HP) Flare Connections Starting current Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. kg 33 36 47 inch 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 A 24 28 50 V-ph-Hz 230-1-50 230-1-50 230-1-50 Installation flexibility with a wide range of accessories. 40SMC_N - SATELLITE UNITS With its compact size and flexibility the Carrier 40SMC ducted system is the ideal choice for both new and refurbished buildings. 40SMC_N FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 40SMC_N FIXED SPEED SPLIT SYSTEM CONTROLS 8 sizes in cooling only and heat pump capacities from: 2,71kW to 13,6kW in cooling; 3,2kW to 14,00kW in heating. FEATURES The preferred solution for consultants and installers - quick and easy to install, compatible with existing electrical and plumbing systems. Ducted system - the ideal choice for both new and refurbished houses. Filters, coils, motors and valves are easily accessible by removing only a few screws. Powerful three-speed direct-drive fan delivers air at up to 80 Pa external static pressure. Unique slim-line profile - the low unit height permits installation even in low ceilings. Compact and 30% lighter than other ducted units on the market. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Electric heater. Hot water coil and anti-freeze thermostat. Mixing box for fresh air. Suction plenum. Discharge plenum. Octopus - two, three or four outlets. High-efficiency gravimetric filter. 3-way, 4-connection valve for hot water coil. MyComfort infrared control kit. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 42 43 40DMC - SATELLITE UNITS FIXED SPEED SPLIT SYSTEM Indoor unit 40DMC018 40DMC024 40DMC028 40DMC036 40DMC036 40DMC052 40DMC060 Outdoor unit (CO) 38GL-018G 38GL-024G 38GL-028G9 38GL-036G9 38GL-048G9 38GL-052G9 38GL-060G9 Cooling capacity (CO) kW 5,40 6,48 8,12 8,48 9,78 11,60 13,49 Power input (CO) W 2151 2763 3022 3201 3085 4319 4797 W/W 2,51 2,34 2,69 2,65 3,17 2,69 2,81 E F D D B D na 1075 1381 1511 1600 1542 2160 - 38YY-018G 38YY-024G 38YY-028G9 38YY-036G9 38YY048G9 38YY0-052G9 38YY-060G9 EER Energy efficiency class (CO) Annual energy consumption kWh Outdoor unit (HP) Cooling capacity (CO) kW 5,42 6,63 8,12 8,63 10,19 12,03 13,77 Power input (CO) W 2038 2670 3040 3339 3453 4282 5041 W/W 2,66 2,48 2,67 2,59 2,95 2,81 2,73 D E D E C na na EER Energy efficiency class (CO) Annual energy consumption kWh 1019 1335 1520 1669 1726 - - Heating capacity kW 5,64 7,02 8,22 9,44 11,02 13,28 14,50 Power input (HP) W 1828 2444 2278 2551 3358 4166 4110 W/W 3,09 2,87 3,61 3,70 3,28 3,19 3,53 D D A A C na na COP Energy efficiency class (HP) Indoor unit 18 24 28 36 48 52 60 l/h 1,6 2,0 2,3 2,0 3,1 3,8 4,0 Nominal air flow (l/m/h) l/s 210/263/294 205/211/269 244/318/383 291/380/463 291/380/463 390/476/564 569/616/667 Nominal static pressure Pa 50 50 50 80 80 80 80 Sound pressure level (l/m/h) dB(A)* 39/40/42 38/40/42 40/43/46 44/46/49 44/46/49 46/49/54 47/51/54 Sound power level (l/m/h) dB(A) 52/53/55 51/53/55 53/56/59 57/59/64 57/59/64 59/62/67 60/64/67 mm 925x750x285 925x750x285 925x750x285 1325x750x285 1325x750x285 1325x750x285 1325x750x285 Dehumidification Dimensions (H x L x D) Weight Power Supply kg 32 35 35 48 48 48 53 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Outdoor unit (CO/HP) Compressor Type 18 24 28 36 48 52 60 rotary rotary scroll scroll scroll scroll scroll Maximum pipe length m 30 40 40 50 50 50 50 Maximum height difference m 15 15 25 30 30 30 30 Chargeless length m 8 8 8 8 8 8 8 Air flow l/s 667 528 667 667 1361 1361 1361 dB(A)** 45/46 45/49 48/48 49/52 53/54 53/54 52/53 Sound power level (CO/HP) dB(A) 65/66 65/69 68/68 69/72 73/74 73/74 72/73 Dimensions (H x L x D) (CO) mm 590x800x300 590x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 1264x800x300 Sound pressure level (CO/HP) Weight (CO) kg 45 51 65 65 92 94 94 Dimensions (H x L x D) (HP) mm 590x800x300 803x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 1264x800x300 Weight (HP) kg 47 60 67 68 94 96 96 inch 1/2 - 1/4 1/2 - 1/4 5/8 - 1/4 3/4 - 3/8 3/4 - 3/8 3/4 - 3/8 3/4 - 3/8 A 50 56 37 39 54 64 64 V-ph-Hz 230-1-50 230-1-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 Flare Connections Starting current Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. 285 Ultra-slim profile - only 285 mm for all sizes, thanks to the Carrier-patented V-shaped coil. 40DMC - SATELLITE UNITS 40DMC FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 40DMC 40DMC Satellite CONTROLS The new ducted above-ceiling units from Carrier represent a breakthrough in design terms. The slimmest profile ever and flexible installation options make these units the best choice for homes and small commercial premises. 7 sizes in cooling only and heat pump capacities from: 5,49kW to 13,4kW in cooling; 5,31kW to 14,55kW in heating. FEATURES Designed for front or side air discharge. Unique design with lateral air discharge allows the unit to be installed in a corridor. Modular filter and panel sizes allow flexible unit mounting with rear or bottom air return. Equipped with pre-punched 150-mm diameter fresh air intakes on both sides, and with pre-punched Octopus discharge panel. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Hot water coil. Electric heater. MyComfort infrared control kit. Control box equipped with 1.5-m cable for flexible positioning and accessibility. Both electric heater and hot water coil are retrofit outside the unit for easy mounting on installed units. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 44 45 40DMC - SATELLITE UNITS FIXED SPEED SPLIT SYSTEM Indoor unit 40DMC018 40DMC024 40DMC028 40DMC036 40DMC036 40DMC052 40DMC060 Outdoor unit (CO) 38GL-018G 38GL-024G 38GL-028G9 38GL-036G9 38GL-048G9 38GL-052G9 38GL-060G9 Cooling capacity (CO) kW 5,40 6,48 8,12 8,48 9,78 11,60 13,49 Power input (CO) W 2151 2763 3022 3201 3085 4319 4797 W/W 2,51 2,34 2,69 2,65 3,17 2,69 2,81 E F D D B D na 1075 1381 1511 1600 1542 2160 - 38YY-018G 38YY-024G 38YY-028G9 38YY-036G9 38YY048G9 38YY0-052G9 38YY-060G9 EER Energy efficiency class (CO) Annual energy consumption kWh Outdoor unit (HP) Cooling capacity (CO) kW 5,42 6,63 8,12 8,63 10,19 12,03 13,77 Power input (CO) W 2038 2670 3040 3339 3453 4282 5041 W/W 2,66 2,48 2,67 2,59 2,95 2,81 2,73 D E D E C na na EER Energy efficiency class (CO) Annual energy consumption kWh 1019 1335 1520 1669 1726 - - Heating capacity kW 5,64 7,02 8,22 9,44 11,02 13,28 14,50 Power input (HP) W 1828 2444 2278 2551 3358 4166 4110 W/W 3,09 2,87 3,61 3,70 3,28 3,19 3,53 D D A A C na na COP Energy efficiency class (HP) Indoor unit 18 24 28 36 48 52 60 l/h 1,6 2,0 2,3 2,0 3,1 3,8 4,0 Nominal air flow (l/m/h) l/s 210/263/294 205/211/269 244/318/383 291/380/463 291/380/463 390/476/564 569/616/667 Nominal static pressure Pa 50 50 50 80 80 80 80 Sound pressure level (l/m/h) dB(A)* 39/40/42 38/40/42 40/43/46 44/46/49 44/46/49 46/49/54 47/51/54 Sound power level (l/m/h) dB(A) 52/53/55 51/53/55 53/56/59 57/59/64 57/59/64 59/62/67 60/64/67 mm 925x750x285 925x750x285 925x750x285 1325x750x285 1325x750x285 1325x750x285 1325x750x285 Dehumidification Dimensions (H x L x D) Weight Power Supply kg 32 35 35 48 48 48 53 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Outdoor unit (CO/HP) Compressor Type 18 24 28 36 48 52 60 rotary rotary scroll scroll scroll scroll scroll Maximum pipe length m 30 40 40 50 50 50 50 Maximum height difference m 15 15 25 30 30 30 30 Chargeless length m 8 8 8 8 8 8 8 Air flow l/s 667 528 667 667 1361 1361 1361 dB(A)** 45/46 45/49 48/48 49/52 53/54 53/54 52/53 Sound power level (CO/HP) dB(A) 65/66 65/69 68/68 69/72 73/74 73/74 72/73 Dimensions (H x L x D) (CO) mm 590x800x300 590x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 1264x800x300 Sound pressure level (CO/HP) Weight (CO) kg 45 51 65 65 92 94 94 Dimensions (H x L x D) (HP) mm 590x800x300 803x800x300 803x800x300 803x800x300 1264x800x300 1264x800x300 1264x800x300 Weight (HP) kg 47 60 67 68 94 96 96 inch 1/2 - 1/4 1/2 - 1/4 5/8 - 1/4 3/4 - 3/8 3/4 - 3/8 3/4 - 3/8 3/4 - 3/8 A 50 56 37 39 54 64 64 V-ph-Hz 230-1-50 230-1-50 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 Flare Connections Starting current Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. 285 Ultra-slim profile - only 285 mm for all sizes, thanks to the Carrier-patented V-shaped coil. 40DMC - SATELLITE UNITS 40DMC FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 40DMC 40DMC Satellite CONTROLS The new ducted above-ceiling units from Carrier represent a breakthrough in design terms. The slimmest profile ever and flexible installation options make these units the best choice for homes and small commercial premises. 7 sizes in cooling only and heat pump capacities from: 5,49kW to 13,4kW in cooling; 5,31kW to 14,55kW in heating. FEATURES Designed for front or side air discharge. Unique design with lateral air discharge allows the unit to be installed in a corridor. Modular filter and panel sizes allow flexible unit mounting with rear or bottom air return. Equipped with pre-punched 150-mm diameter fresh air intakes on both sides, and with pre-punched Octopus discharge panel. Freedom of choice between infrared remote control and wired controls. ACCESSORIES Hot water coil. Electric heater. MyComfort infrared control kit. Control box equipped with 1.5-m cable for flexible positioning and accessibility. Both electric heater and hot water coil are retrofit outside the unit for easy mounting on installed units. OUTDOOR UNITS Monosplit: 38BC/BH and 38GL/YY Multisplit: 38GL_M/YL_M 44 45 FB4X - VERTICAL DUCTED FIXED SPEED SPLIT SYSTEM Indoor Units FX4CSX024 FX4CSX036 FX4CSX048 FX4CSX060 Outdoor units 38EYX024-7 38EYX036-9 38EYX048-9 38EYX060-9 Cooling capacity kW 6,8 10,0 13,7 16,7 Nominal power input (CO) kW 2,12 3,14 4,36 5,87 Annual Energy Consumption kW/h 1060 1570 na na EER W/W 3,22 3,18 3,13 2,85 Energy efficiency class (CO) kW A B na na Heating capacity kW 6,64 10,39 14,48 17,07 Nominal power input (HP) kW 1,83 2,98 3,82 5,04 W/W 3,63 3,49 3,79 3,39 kW A B na na COP Energy efficiency class HP INDOOR UNITS (FURNACE TYPE) 24 36 48 60 l/h 3,4 4,6 7,0 8,2 Nominal air flow l/s 475 600 750 825 Maximum static pressure Pa 125 125 125 125 dB(A) 72 77 77 80 dB(A)*** 56 61 61 64 Dimensions (HxWxD) mm 1212x448x560 1357x537x560 1261x537x560 1357x537x560 Weight kg 55 67 72 80 Dehumidification Sound power Sound pressure HEAT PUMP CONDENSING UNITS 24 36 48 60 Compressor type scroll scroll scroll scroll Refrigerant type R-410A R-410A R-410A R-410A 50 50 50 50 Maximum pipe lenght Maximum elevation Chargeless piping lenght Additional refrigerant charge Sound power m m* 45 45 45 45 m 4,5 4,5 4,5 4,5 g/m 56 56 56 56 dB(A) 72 72 72 74 Sound pressure dB(A)** 52 52 52 54 Nominal air flow l/s 708 1274 1416 1180 Dimensions (HxWxD) mm 761x572x572 761x762x762 1015x762x762 862x762x762 Weight kg 65,8 83,9 99,3 111,6 Sweat connections (liquid/gas) in 3/8” - 5/8” 3/8” - 3/4” 3/8” - 7/8” 3/8” - 7/8” Maximum running current A 16,2 8,7 12,0 14,0 Installation fuse rating A 25 15 20 20 Nominal power supply V-ph-Hz 230-1-50 400-3-50 400-3-50 400-3-50 (*) : If the CDU is positioned below the IDU, the maximum elevation is 15meters (**) : sound pressure level measured in hemispheric field at 4m distance from the unit (***) : sound pressure level measured in anechoic room at 1,28m from discharge outlet on vertical wall TECH3000 Exceptional installation flexibility - the indoor unit can be installed in three air flow positions: upwards, downwards or horizontal. FB4X - VERTICAL DUCTED Encased indoor fan coils, complete with direct-expansion indoor coil, suitable for use in cooling only and heat pump systems. FB4X FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM FB4X FB4X CONTROLS 4 size in cooling only and heat pump. FEATURES Room thermostat All materials used are designed and protected to resist the toughest climates. Refrigerant circuit service valves with easily accessible pressure test ports for start-up and maintenance. Heat pump cycle with four-position valve (38EYX); electronic control system for optimised defrosting. High and low-pressure safety switches fitted as standard. ACCESSORIES Downflow Convertion Kit Downflow / Horizontal Kit Filter Kit To assure long life and reliability outdoor unit compressors are hermetically sealed against contamination and pollutants. OUTDOOR UNIT 38EYX 46 47 FB4X - VERTICAL DUCTED FIXED SPEED SPLIT SYSTEM Indoor Units FX4CSX024 FX4CSX036 FX4CSX048 FX4CSX060 Outdoor units 38EYX024-7 38EYX036-9 38EYX048-9 38EYX060-9 Cooling capacity kW 6,8 10,0 13,7 16,7 Nominal power input (CO) kW 2,12 3,14 4,36 5,87 Annual Energy Consumption kW/h 1060 1570 na na EER W/W 3,22 3,18 3,13 2,85 Energy efficiency class (CO) kW A B na na Heating capacity kW 6,64 10,39 14,48 17,07 Nominal power input (HP) kW 1,83 2,98 3,82 5,04 W/W 3,63 3,49 3,79 3,39 kW A B na na COP Energy efficiency class HP INDOOR UNITS (FURNACE TYPE) 24 36 48 60 l/h 3,4 4,6 7,0 8,2 Nominal air flow l/s 475 600 750 825 Maximum static pressure Pa 125 125 125 125 dB(A) 72 77 77 80 dB(A)*** 56 61 61 64 Dimensions (HxWxD) mm 1212x448x560 1357x537x560 1261x537x560 1357x537x560 Weight kg 55 67 72 80 Dehumidification Sound power Sound pressure HEAT PUMP CONDENSING UNITS 24 36 48 60 Compressor type scroll scroll scroll scroll Refrigerant type R-410A R-410A R-410A R-410A 50 50 50 50 Maximum pipe lenght Maximum elevation Chargeless piping lenght Additional refrigerant charge Sound power m m* 45 45 45 45 m 4,5 4,5 4,5 4,5 g/m 56 56 56 56 dB(A) 72 72 72 74 Sound pressure dB(A)** 52 52 52 54 Nominal air flow l/s 708 1274 1416 1180 Dimensions (HxWxD) mm 761x572x572 761x762x762 1015x762x762 862x762x762 Weight kg 65,8 83,9 99,3 111,6 Sweat connections (liquid/gas) in 3/8” - 5/8” 3/8” - 3/4” 3/8” - 7/8” 3/8” - 7/8” Maximum running current A 16,2 8,7 12,0 14,0 Installation fuse rating A 25 15 20 20 Nominal power supply V-ph-Hz 230-1-50 400-3-50 400-3-50 400-3-50 (*) : If the CDU is positioned below the IDU, the maximum elevation is 15meters (**) : sound pressure level measured in hemispheric field at 4m distance from the unit (***) : sound pressure level measured in anechoic room at 1,28m from discharge outlet on vertical wall TECH3000 Exceptional installation flexibility - the indoor unit can be installed in three air flow positions: upwards, downwards or horizontal. FB4X - VERTICAL DUCTED Encased indoor fan coils, complete with direct-expansion indoor coil, suitable for use in cooling only and heat pump systems. FB4X FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM FB4X FB4X CONTROLS 4 size in cooling only and heat pump. FEATURES Room thermostat All materials used are designed and protected to resist the toughest climates. Refrigerant circuit service valves with easily accessible pressure test ports for start-up and maintenance. Heat pump cycle with four-position valve (38EYX); electronic control system for optimised defrosting. High and low-pressure safety switches fitted as standard. ACCESSORIES Downflow Convertion Kit Downflow / Horizontal Kit Filter Kit To assure long life and reliability outdoor unit compressors are hermetically sealed against contamination and pollutants. OUTDOOR UNIT 38EYX 46 47 38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS FIXED SPEED SPLIT SYSTEM Flare connections [A] inch 38GL2M12G Rotary Shared – 15 5 15 331 43 63 590x660x250 39 2 3/8 - 1/4 1/2 - 1/4 Flare connections [B] inch - 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 3/8 - 1/4 3/8 - 1/4 A V-ph-Hz 30 230-1-50 30 + 30 230-1-50 30 + 30 230-1-50 50 + 50 230-1-50 60 + 60 230-1-50 30 + 30 230-1-50 30 + 50 230-1-50 38YY2M18G Rotary dedicated dedicated 15 + 15 5 8+8 15/15 167 45 65 590x800x300 55 2 3/8 - 1/4 3/8 - 1/4 25 + 25 230-1-50 38YY2M21G Rotary dedicated dedicated 15 + 15 5 8+8 15/15 210 48 68 803x800x300 61 2 1/2 - 1/4 1/2 - 1/4 25 + 30 230-1-50 Starting current Power Supply Outdoor unit (HP) Compressor Type Compressor [A] Compressor [B] Maximum pipe length Maximum height difference Chargeless length Additional charge Air flow Sound pressure level* Sound power level Dimensions (H x L x D) Weight Max. number of indoor units Flare connections [A] Flare connections [B] Starting current Power Supply * [A] [B] m m m g/m l/s dB(A) dB(A) mm kg m m m g/m l/s dB(A) dB(A) mm kg inch inch A V-ph-Hz 38GL2M18G Rotary dedicated dedicated 15 + 15 5 8+8 15 533 45 65 590x800x300 55 2 3/8 - 1/4 38GL2M24G 38GL2M36G 38GL2M48G 38GL3M21G Rotary Rotary Rotary Rotary dedicated dedicated dedicated shared dedicated dedicated dedicated dedicated 15 + 15 30 + 30 40 + 40 15 + 15 5 10 15 5 8+8 8+8 8+8 8 + 15 15 15 15 15/686 553 + 553 553 + 553 528 48 49 50 46 68 69 70 66 590x800x300 1264x800x300 1264x800x300 590x800x300 64 99 102 58 2 2 2 3 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 38GL3M30G Rotary shared dedicated 15+30 5 8 + 15 15/553 50 70 803x800x300 75 3 3/8 - 1/4 1/2 - 1/4 38GL4M24G Rotary shared shared 30 + 30 5 15 + 15 15/15 769 50 70 803x800x300 69 4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 30 + 30 230-1-50 38YY2M24G 38YY2M36G 38YY2M48G Rotary Rotary Rotary dedicated dedicated dedicated dedicated dedicated dedicated 15 + 15 30 + 30 40 + 40 5 15 15 8+8 8+8 8+8 15/15 20/20 20/20 210 150 179 48 49 50 68 69 70 803x800x300 1264x800x300 1264x800x300 64 99 102 2 2 2 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 30 + 30 50 + 50 60 + 60 230-1-50 230-1-50 230-1-50 Sound pressure level in emispheric field at 4 m. Performances evaluated with 5m interconnecting tubes. DEDICATED COMPRESSORS Ultra-reliable compressor. Ideal for both residential and small business applications. 38GL_M/YY_M - AIR-COOLED CONDENSING UNITS CONTROLS 8 models cooling only from 2kW to 13kW and 5 models in heat pump from 5kW to 14kW FEATURES SHARED COMPRESSORS 38GL_M/YY_M FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M 38GL_M/YY_M Multi-split Condensing Unit Outdoor unit (CO Compressor Type Compressor Compressor Maximum pipe length Maximum height difference Chargeless length Additional charge Air flow Sound pressure level* Sound power level Dimensions (H x L x D) Weight Max. number of indoor units Design and components optimised for operation with R410A refrigerant. Rotary or scroll compressor, synonymous with high reliability and energy efficiency. Modular control system ACCESSORIES/OPTIONS Wall bracket Low ambient kit Exceptionally low noise fan. New generation coil for optimised heat transfer. INDOOR UNITS Reduced unit size and weight make this one of the most compact units in its class on the market. For power For economy To satisfy the needs of shops and offices, where maximium power is required simultaneously in more than one space, Carrier offers models with two dedicated compressors each serving one indoor unit, so that the power of each compressor is exploited to the full. Ideal to air-condition spaces where maximum conditioning power is not usually required simultaneously, such as the daytime and night-time areas of a house, Carrier has developed the multisplit with split compressor. Low-ambient device guarantees optimum and safe operation, even at extremely low outside temperatures (down to -15°C for 38GLS/YLS). 42PHQ_S 42VMC 40KMC 40SMC 40DMC 48 49 38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS FIXED SPEED SPLIT SYSTEM Flare connections [A] inch 38GL2M12G Rotary Shared – 15 5 15 331 43 63 590x660x250 39 2 3/8 - 1/4 1/2 - 1/4 Flare connections [B] inch - 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 3/8 - 1/4 3/8 - 1/4 A V-ph-Hz 30 230-1-50 30 + 30 230-1-50 30 + 30 230-1-50 50 + 50 230-1-50 60 + 60 230-1-50 30 + 30 230-1-50 30 + 50 230-1-50 38YY2M18G Rotary dedicated dedicated 15 + 15 5 8+8 15/15 167 45 65 590x800x300 55 2 3/8 - 1/4 3/8 - 1/4 25 + 25 230-1-50 38YY2M21G Rotary dedicated dedicated 15 + 15 5 8+8 15/15 210 48 68 803x800x300 61 2 1/2 - 1/4 1/2 - 1/4 25 + 30 230-1-50 Starting current Power Supply Outdoor unit (HP) Compressor Type Compressor [A] Compressor [B] Maximum pipe length Maximum height difference Chargeless length Additional charge Air flow Sound pressure level* Sound power level Dimensions (H x L x D) Weight Max. number of indoor units Flare connections [A] Flare connections [B] Starting current Power Supply * [A] [B] m m m g/m l/s dB(A) dB(A) mm kg m m m g/m l/s dB(A) dB(A) mm kg inch inch A V-ph-Hz 38GL2M18G Rotary dedicated dedicated 15 + 15 5 8+8 15 533 45 65 590x800x300 55 2 3/8 - 1/4 38GL2M24G 38GL2M36G 38GL2M48G 38GL3M21G Rotary Rotary Rotary Rotary dedicated dedicated dedicated shared dedicated dedicated dedicated dedicated 15 + 15 30 + 30 40 + 40 15 + 15 5 10 15 5 8+8 8+8 8+8 8 + 15 15 15 15 15/686 553 + 553 553 + 553 528 48 49 50 46 68 69 70 66 590x800x300 1264x800x300 1264x800x300 590x800x300 64 99 102 58 2 2 2 3 3/8 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 38GL3M30G Rotary shared dedicated 15+30 5 8 + 15 15/553 50 70 803x800x300 75 3 3/8 - 1/4 1/2 - 1/4 38GL4M24G Rotary shared shared 30 + 30 5 15 + 15 15/15 769 50 70 803x800x300 69 4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 30 + 30 230-1-50 38YY2M24G 38YY2M36G 38YY2M48G Rotary Rotary Rotary dedicated dedicated dedicated dedicated dedicated dedicated 15 + 15 30 + 30 40 + 40 5 15 15 8+8 8+8 8+8 15/15 20/20 20/20 210 150 179 48 49 50 68 69 70 803x800x300 1264x800x300 1264x800x300 64 99 102 2 2 2 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4 30 + 30 50 + 50 60 + 60 230-1-50 230-1-50 230-1-50 Sound pressure level in emispheric field at 4 m. Performances evaluated with 5m interconnecting tubes. DEDICATED COMPRESSORS Ultra-reliable compressor. Ideal for both residential and small business applications. 38GL_M/YY_M - AIR-COOLED CONDENSING UNITS CONTROLS 8 models cooling only from 2kW to 13kW and 5 models in heat pump from 5kW to 14kW FEATURES SHARED COMPRESSORS 38GL_M/YY_M FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M 38GL_M/YY_M Multi-split Condensing Unit Outdoor unit (CO Compressor Type Compressor Compressor Maximum pipe length Maximum height difference Chargeless length Additional charge Air flow Sound pressure level* Sound power level Dimensions (H x L x D) Weight Max. number of indoor units Design and components optimised for operation with R410A refrigerant. Rotary or scroll compressor, synonymous with high reliability and energy efficiency. Modular control system ACCESSORIES/OPTIONS Wall bracket Low ambient kit Exceptionally low noise fan. New generation coil for optimised heat transfer. INDOOR UNITS Reduced unit size and weight make this one of the most compact units in its class on the market. For power For economy To satisfy the needs of shops and offices, where maximium power is required simultaneously in more than one space, Carrier offers models with two dedicated compressors each serving one indoor unit, so that the power of each compressor is exploited to the full. Ideal to air-condition spaces where maximum conditioning power is not usually required simultaneously, such as the daytime and night-time areas of a house, Carrier has developed the multisplit with split compressor. Low-ambient device guarantees optimum and safe operation, even at extremely low outside temperatures (down to -15°C for 38GLS/YLS). 42PHQ_S 42VMC 40KMC 40SMC 40DMC 48 49 38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M PERFORMANCES 38GL_M (DUAL SPLIT) PERFORMANCES 38GL_M (TRI SPLIT) Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption 38GL2M12G 09+09 38GL2M12G 09+012 38GL2M18G 09+09 38GL2M24G 12+12 38GL2M36G 18+18 38GL2M48G 24+24 kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh 42PHQ-S 3,80 1550 2,45 E 775 3,81 1570 2,43 E 785 5,31 2170 2,45 E 1085 7,02 2780 2,53 E 1390 10,46 4050 2,58 E 2025 12,60 5220 2,41 na 2610 42VMC-N 3,76 1550 2,43 E 775 3,78 1550 2,44 E 775 4,90 2080 2,36 F 1040 6,89 2730 2,52 E 1365 10,28 3970 2,59 E 1985 12,80 5320 2,41 na 2660 40KMC-N 7,17 2860 2,51 E 1430 10,74 3990 2,69 D 1995 13,20 5300 2,49 na 2650 40SMC-N 3,10 1720 1,80 G 860 3,91 1730 2,26 F 865 5,40 2730 1,98 G 1365 7,00 3040 2,30 F 1520 9,45 4160 2,27 F 2080 12,50 5410 2,31 na 2705 40DMC 10,02 3890 2,58 E 1945 13,00 5500 2,36 na 2750 38GL3M21G 09+09+09 38GL3M21G 09+09+12 38GL3M30G 09+09+18 38GL3M30G 09+12+18 INDOOR UNITS Operations 38GL2M12G 38GL2M18G 38GL2M24G 38GL2M36G 38GL2M48G Circuit B --------09 12 18 24 Total 3,14 3,25 3,80 3,81 5,31 7,02 10,46 12,60 Cooling Capacity (W) Circuit A 3,14 3,25 1,90 1,90 1,88 1,93 2,66 3,51 5,23 6,30 Circuit B --------2,66 3,51 5,23 6,30 kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh 42PHQ-S 5,86 2360 2,48 E 1180 5,97 2380 2,51 E 1190 8,49 3670 2,31 F 1835 8,55 3690 2,32 F 1845 42VMC-N 5,82 2360 2,47 E 1180 5,86 2380 2,46 E 1190 8,73 3720 2,35 F 1860 8,79 3740 2,35 F 1870 40KMC-N 8,75 3710 2,36 F 1855 8,81 3730 2,36 F 1865 40SMC-N 5,92 2620 2,26 F 1310 5,96 2640 2,26 F 1320 8,40 3720 2,26 F 1860 8,46 3750 2,26 F 1875 40DMC - 38GL3M30G 09 09 12 09+09 12+09 09+09 09+09+09 09+12+09 09 12 18 09+09 09+18 12+18 09+09+18 09+12+18 Circuit A 09 --12 09 12 09+09 09+09 09+12 09 12 --09+09 09 12 09+09 09+12 Circuit B --09 --09 09 --09 09 ----18 --18 18 18 18 Total 2,89 2,32 2,97 5,17 5,25 3,58 5,86 5,90 2,89 2,97 5,47 3,72 7,88 7,96 8,49 8,55 Cooling Capacity (W Circuit A 2,89 --2,97 2,87 2,95 1,79+1,79 1,78+1,78 1,78+1,82 2,89 2,97 --1,86 1,86 2,87 2,95 1,74 1,74 1,74 1,80 Circuit B --2,32 --2,30 2,30 --2,30 2,30 ----5,47 --5,01 5,01 5,01 5,01 FIXED SPEED SPLIT SYSTEM INDOOR UNITS COMBINATION Circuit A 09 012 09+09 09+012 09 12 18 24 kW W W/W INDOOR UNITS COMBINATION 38GL3M21G INDOOR UNITS Operations 09 12 09+09 09+12 09+09 12+12 18+18 24+24 Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Data referred to combination with 42PHQ_P DUAL SPLIT (Cooling) 38GL2M12G 50 38GL2M18G 38GL2M24G TRI SPLIT 38GL2M36G 38GL2M48G 38GL3M21G 38GL3M30G 51 38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M PERFORMANCES 38GL_M (DUAL SPLIT) PERFORMANCES 38GL_M (TRI SPLIT) Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption 38GL2M12G 09+09 38GL2M12G 09+012 38GL2M18G 09+09 38GL2M24G 12+12 38GL2M36G 18+18 38GL2M48G 24+24 kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh 42PHQ-S 3,80 1550 2,45 E 775 3,81 1570 2,43 E 785 5,31 2170 2,45 E 1085 7,02 2780 2,53 E 1390 10,46 4050 2,58 E 2025 12,60 5220 2,41 na 2610 42VMC-N 3,76 1550 2,43 E 775 3,78 1550 2,44 E 775 4,90 2080 2,36 F 1040 6,89 2730 2,52 E 1365 10,28 3970 2,59 E 1985 12,80 5320 2,41 na 2660 40KMC-N 7,17 2860 2,51 E 1430 10,74 3990 2,69 D 1995 13,20 5300 2,49 na 2650 40SMC-N 3,10 1720 1,80 G 860 3,91 1730 2,26 F 865 5,40 2730 1,98 G 1365 7,00 3040 2,30 F 1520 9,45 4160 2,27 F 2080 12,50 5410 2,31 na 2705 40DMC 10,02 3890 2,58 E 1945 13,00 5500 2,36 na 2750 38GL3M21G 09+09+09 38GL3M21G 09+09+12 38GL3M30G 09+09+18 38GL3M30G 09+12+18 INDOOR UNITS Operations 38GL2M12G 38GL2M18G 38GL2M24G 38GL2M36G 38GL2M48G Circuit B --------09 12 18 24 Total 3,14 3,25 3,80 3,81 5,31 7,02 10,46 12,60 Cooling Capacity (W) Circuit A 3,14 3,25 1,90 1,90 1,88 1,93 2,66 3,51 5,23 6,30 Circuit B --------2,66 3,51 5,23 6,30 kWh kW W W/W kWh kW W W/W kWh kW W W/W kWh 42PHQ-S 5,86 2360 2,48 E 1180 5,97 2380 2,51 E 1190 8,49 3670 2,31 F 1835 8,55 3690 2,32 F 1845 42VMC-N 5,82 2360 2,47 E 1180 5,86 2380 2,46 E 1190 8,73 3720 2,35 F 1860 8,79 3740 2,35 F 1870 40KMC-N 8,75 3710 2,36 F 1855 8,81 3730 2,36 F 1865 40SMC-N 5,92 2620 2,26 F 1310 5,96 2640 2,26 F 1320 8,40 3720 2,26 F 1860 8,46 3750 2,26 F 1875 40DMC - 38GL3M30G 09 09 12 09+09 12+09 09+09 09+09+09 09+12+09 09 12 18 09+09 09+18 12+18 09+09+18 09+12+18 Circuit A 09 --12 09 12 09+09 09+09 09+12 09 12 --09+09 09 12 09+09 09+12 Circuit B --09 --09 09 --09 09 ----18 --18 18 18 18 Total 2,89 2,32 2,97 5,17 5,25 3,58 5,86 5,90 2,89 2,97 5,47 3,72 7,88 7,96 8,49 8,55 Cooling Capacity (W Circuit A 2,89 --2,97 2,87 2,95 1,79+1,79 1,78+1,78 1,78+1,82 2,89 2,97 --1,86 1,86 2,87 2,95 1,74 1,74 1,74 1,80 Circuit B --2,32 --2,30 2,30 --2,30 2,30 ----5,47 --5,01 5,01 5,01 5,01 FIXED SPEED SPLIT SYSTEM INDOOR UNITS COMBINATION Circuit A 09 012 09+09 09+012 09 12 18 24 kW W W/W INDOOR UNITS COMBINATION 38GL3M21G INDOOR UNITS Operations 09 12 09+09 09+12 09+09 12+12 18+18 24+24 Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Data referred to combination with 42PHQ_P DUAL SPLIT (Cooling) 38GL2M12G 50 38GL2M18G 38GL2M24G TRI SPLIT 38GL2M36G 38GL2M48G 38GL3M21G 38GL3M30G 51 38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS FIXED SPEED SPLIT SYSTEM 38GL4M24G '09+09+09+09 38GL4M24G 09+09+09+12 38GL4M24G 09+12+09+12 Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption PERFORMANCES 38YY_M (DUAL SPLIT HEATING) kW W W/W kWh kW W W/W kWh kW W W/W kWh 42PHQ_S 6,96 2760 2,52 E 1380 7,00 2790 2,51 E 1395 7,04 2840 2,48 E 1420 42VMC-N 7,02 2750 2,55 E 1375 7,05 2780 2,54 E 1390 7,10 2810 2,53 E 1405 40KMC-N 6,98 2740 2,55 E 1370 7,02 2810 2,50 E 1405 40SMC-N 7,13 3070 2,32 F 1535 7,17 3100 2,31 F 1550 7,21 3150 2,29 F 1575 40DMC - 38GL4M24G 09 12 09+09 09+09 09+12 09+12 12+12 09+09+09 09+09+12 09+09+12 09+12+12 09+09+09+09 09+09+09+12 09+12+09+12 38YY2M21G 09+12 38YY2M24G 12+12 INDOOR UNITS COMBINATION INDOOR UNITS Operations 38YY2M18G 09+09 Circuit A 09 12 09+09 09 09+012 09 12 09+09 09+12 09+09 09+12 09+09 09+09 09+12 Circuit B ------09 --12 12 09 09 12 12 09+09 09+12 09+12 Total 2,83 2,87 3,60 5,42 3,64 5,47 5,50 6,22 6,26 6,26 6,30 6,96 7,00 7,04 1,80 1,80 1,74 1,74 1,74 1,74 1,74 1,74 1,74 Cooling Capacity (W Circuit A 2,83 2,87 1,80 2,71 1,84 2,71 2,75 1,74 1,78 1,74 1,78 1,74 1,74 1,78 Circuit B ------2,71 --2,76 2,75 2,74 2,74 2,78 2,78 1,74 1,74 1,74 38YY2M36G 38YYS2M36G 18+18 1,74 1,78 1,78 38YY2M48G 38YYS2M48G 24+24 Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) QUADRI SPLIT 38GL4M24G 52 kW W W/W kWh kW W W/W kW W W/W kWh kW W W/W kW W W/W kWh kW W W/W kW W W/W kWh kW W W/W kWh kW W W/W kW W W/W 42PHQ_S 5,55 2080 2,67 D 1040 5,83 1860 3,13 D 6,45 2310 2,79 D 1155 6,95 2300 3,02 D 6,80 2660 2,56 E 1330 7,05 2460 2,87 D 9,87 3770 2,62 D 1885 10,60 3490 3,04 D 12,10 4900 2,47 na 2450 14,20 5220 2,72 na 42VMC-N 5,29 1930 2,74 D 965 5,58 1970 2,83 D 6,16 2180 2,83 C 1090 6,67 2420 2,76 E 6,50 2510 2,59 E 1255 6,80 2550 2,67 E 10,00 3890 2,57 E 1945 10,90 3650 2,99 D 13,00 5080 2,56 na 2540 13,80 5360 2,57 na 40KMC-N 6,62 2640 2,51 E 1320 6,96 2490 2,80 E 9,78 3850 2,54 E 1925 11,5 3650 3,15 D 12,7 4980 2,55 na 2490 13,6 5400 2,52 na 40SMC-N 5,05 2140 2,36 F 1070 5,48 2080 2,63 E 5,84 2440 2,39 F 1220 6,47 2540 2,55 F 6,12 2860 2,14 G 1430 6,50 2660 2,44 F 9,23 3960 2,33 F 1980 10,40 3930 2,65 E 12,08 4560 2,65 na 2280 14,20 5000 2,84 na 40DMC 9,95 3750 2,65 D 1875 10,80 3350 3,22 C 13,20 4920 2,68 na 2460 14,20 4800 2,96 na 38GL_M/YY_M FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M PERFORMANCES 38GL_M (QUADRI SPLIT) DUAL SPLIT 38YY2M18G 38YY2M21G 38YY2M24G 38YY2M36G 38YY2M48G 53 38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS FIXED SPEED SPLIT SYSTEM 38GL4M24G '09+09+09+09 38GL4M24G 09+09+09+12 38GL4M24G 09+12+09+12 Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption Cooling Capacity Power Input EER Energy efficiency class Annual energy consumption PERFORMANCES 38YY_M (DUAL SPLIT HEATING) kW W W/W kWh kW W W/W kWh kW W W/W kWh 42PHQ_S 6,96 2760 2,52 E 1380 7,00 2790 2,51 E 1395 7,04 2840 2,48 E 1420 42VMC-N 7,02 2750 2,55 E 1375 7,05 2780 2,54 E 1390 7,10 2810 2,53 E 1405 40KMC-N 6,98 2740 2,55 E 1370 7,02 2810 2,50 E 1405 40SMC-N 7,13 3070 2,32 F 1535 7,17 3100 2,31 F 1550 7,21 3150 2,29 F 1575 40DMC - 38GL4M24G 09 12 09+09 09+09 09+12 09+12 12+12 09+09+09 09+09+12 09+09+12 09+12+12 09+09+09+09 09+09+09+12 09+12+09+12 38YY2M21G 09+12 38YY2M24G 12+12 INDOOR UNITS COMBINATION INDOOR UNITS Operations 38YY2M18G 09+09 Circuit A 09 12 09+09 09 09+012 09 12 09+09 09+12 09+09 09+12 09+09 09+09 09+12 Circuit B ------09 --12 12 09 09 12 12 09+09 09+12 09+12 Total 2,83 2,87 3,60 5,42 3,64 5,47 5,50 6,22 6,26 6,26 6,30 6,96 7,00 7,04 1,80 1,80 1,74 1,74 1,74 1,74 1,74 1,74 1,74 Cooling Capacity (W Circuit A 2,83 2,87 1,80 2,71 1,84 2,71 2,75 1,74 1,78 1,74 1,78 1,74 1,74 1,78 Circuit B ------2,71 --2,76 2,75 2,74 2,74 2,78 2,78 1,74 1,74 1,74 38YY2M36G 38YYS2M36G 18+18 1,74 1,78 1,78 38YY2M48G 38YYS2M48G 24+24 Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) Cooling Capacity Power input (CO) EER Energy efficiency class(CO) Annual energy consumption Heating capacity Power input (HP) COP Energy efficiency class (HP) QUADRI SPLIT 38GL4M24G 52 kW W W/W kWh kW W W/W kW W W/W kWh kW W W/W kW W W/W kWh kW W W/W kW W W/W kWh kW W W/W kWh kW W W/W kW W W/W 42PHQ_S 5,55 2080 2,67 D 1040 5,83 1860 3,13 D 6,45 2310 2,79 D 1155 6,95 2300 3,02 D 6,80 2660 2,56 E 1330 7,05 2460 2,87 D 9,87 3770 2,62 D 1885 10,60 3490 3,04 D 12,10 4900 2,47 na 2450 14,20 5220 2,72 na 42VMC-N 5,29 1930 2,74 D 965 5,58 1970 2,83 D 6,16 2180 2,83 C 1090 6,67 2420 2,76 E 6,50 2510 2,59 E 1255 6,80 2550 2,67 E 10,00 3890 2,57 E 1945 10,90 3650 2,99 D 13,00 5080 2,56 na 2540 13,80 5360 2,57 na 40KMC-N 6,62 2640 2,51 E 1320 6,96 2490 2,80 E 9,78 3850 2,54 E 1925 11,5 3650 3,15 D 12,7 4980 2,55 na 2490 13,6 5400 2,52 na 40SMC-N 5,05 2140 2,36 F 1070 5,48 2080 2,63 E 5,84 2440 2,39 F 1220 6,47 2540 2,55 F 6,12 2860 2,14 G 1430 6,50 2660 2,44 F 9,23 3960 2,33 F 1980 10,40 3930 2,65 E 12,08 4560 2,65 na 2280 14,20 5000 2,84 na 40DMC 9,95 3750 2,65 D 1875 10,80 3350 3,22 C 13,20 4920 2,68 na 2460 14,20 4800 2,96 na 38GL_M/YY_M FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M PERFORMANCES 38GL_M (QUADRI SPLIT) DUAL SPLIT 38YY2M18G 38YY2M21G 38YY2M24G 38YY2M36G 38YY2M48G 53 CONTROLS RANGE KIT FOR SATELLITE UNITS LOCAL WIRED CONTROL BUILDING MANAGEMENT ROOM CONTROLLER 33MC-RC ZONE MANAGER 33MC-ZM Wall receiver for ducted satellite units Fixed speed and XPower inverter. MAIN FUNCTIONS: 1 x 6 WIRED CONTROL FOR SINGLE APPLICATIONS: 8 x This small and elegant wall mounted control serves up to 6 unitswith the same operating setting. 32 SYSTEMS MONITORING: This building supervisor can control and set schedules up to 32 different indoors units in 8 indipendent zones. CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS DIRECT EXPANSION SPLIT SYSTEMS CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS ALUMINIUM COLOR The basic and most used buttons are ergonomically placed for intuitive and user friendly operations. MY COMFORT: Allows selection and memorization of the favourite end-user setting via the remote control. LIQUID CRYSTAL DISPLAY: WEEKLY PROGRAMMING All settings and operation paremeters clearly displayed. User can select four individual start/stop ranges per day of the week for each zone. EASY MODE AND FAN SELECTION BUTTON: ZONE SETTINGS AND LOCAL OPERATION: Quick choice between cooling, heating, dehumidification, fan only or auto. Any individual unit within each zone can be operated by the end-user according to his desires by overiding zone setting. GROUPING FUNCTIONALITY: AUTONOMOUS OPERATION: This control is suitable to operate up to 6 units located in the same zone. ( 1 accessoty usable for up to 5 slave units is required for proper installation of 33MC9002). If power failure occurs, clock operations are maintained for up to 20 hours, while programmed parameters are kept in the memory. EXTRA POWER: With this setting the fan will run at maximum speed and the setpoint will be reached quickly. IONIZER: The ionizer can be operated separately, to deliver millions of negative ions in the ambient and give an immediate sensation of well-being. Available for XPower sensation (42PQV_S) in style with the unit design. ECONOMY: The unit will work at low speed for maximum energy saving and silent operation. LOUVRE CONTROL: HiWall Fixed speed Inverter 54 42PQV (LC) Air flow direction can be remotely adjusted to optimized the air flow distribution and suit individual preferences. Console Cassette Satellite 42VMC 40KMC 40SMC 40DMC PROGRAMMING FUNCTIONS: 42VQV 40KQV 40SQV 40DQV Clock and 24 hours timer, sleep mode or continous programming settings are easily available. Function may vary depending on the unit 55 CONTROLS RANGE KIT FOR SATELLITE UNITS LOCAL WIRED CONTROL BUILDING MANAGEMENT ROOM CONTROLLER 33MC-RC ZONE MANAGER 33MC-ZM Wall receiver for ducted satellite units Fixed speed and XPower inverter. MAIN FUNCTIONS: 1 x 6 WIRED CONTROL FOR SINGLE APPLICATIONS: 8 x This small and elegant wall mounted control serves up to 6 unitswith the same operating setting. 32 SYSTEMS MONITORING: This building supervisor can control and set schedules up to 32 different indoors units in 8 indipendent zones. CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS DIRECT EXPANSION SPLIT SYSTEMS CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS ALUMINIUM COLOR The basic and most used buttons are ergonomically placed for intuitive and user friendly operations. MY COMFORT: Allows selection and memorization of the favourite end-user setting via the remote control. LIQUID CRYSTAL DISPLAY: WEEKLY PROGRAMMING All settings and operation paremeters clearly displayed. User can select four individual start/stop ranges per day of the week for each zone. EASY MODE AND FAN SELECTION BUTTON: ZONE SETTINGS AND LOCAL OPERATION: Quick choice between cooling, heating, dehumidification, fan only or auto. Any individual unit within each zone can be operated by the end-user according to his desires by overiding zone setting. GROUPING FUNCTIONALITY: AUTONOMOUS OPERATION: This control is suitable to operate up to 6 units located in the same zone. ( 1 accessoty usable for up to 5 slave units is required for proper installation of 33MC9002). If power failure occurs, clock operations are maintained for up to 20 hours, while programmed parameters are kept in the memory. EXTRA POWER: With this setting the fan will run at maximum speed and the setpoint will be reached quickly. IONIZER: The ionizer can be operated separately, to deliver millions of negative ions in the ambient and give an immediate sensation of well-being. Available for XPower sensation (42PQV_S) in style with the unit design. ECONOMY: The unit will work at low speed for maximum energy saving and silent operation. LOUVRE CONTROL: HiWall Fixed speed Inverter 54 42PQV (LC) Air flow direction can be remotely adjusted to optimized the air flow distribution and suit individual preferences. Console Cassette Satellite 42VMC 40KMC 40SMC 40DMC PROGRAMMING FUNCTIONS: 42VQV 40KQV 40SQV 40DQV Clock and 24 hours timer, sleep mode or continous programming settings are easily available. Function may vary depending on the unit 55 42HQE_G - HIGH-WALL UNITS FIXED SPEED SPLIT SYSTEM 42HQE_G 42HQE009G 38YE009G 42HQE012G 38YE012G Cooling capacity (CO) kW 2,5 3,5 Power Input (CO) W 889 1245 W/W 2,81 2,81 E.E.R. Energy efficiency class (CO) C C 445 623 Annual Energy Consumption kWh Heating Capacity kW 2,9 4,0 Power Input (HP) W 903 1246 W/W 3,21 3,21 C C 009 012 C.O.P. Energy Efficiency Class (HP) Indoor unit Dehumidification l/h 1,0 1,2 Nominal air flow (l/m/h) l/s 97/110/125 105/130/178 Sound pressure (l/m/h) dB(A)* 33/36/39 32/35/42 Sound power (l/m/h) dB(A) 47/49/52 45/48/55 Dimensions (HxLxD) mm 250x750x188 280x815x195 Weight Power Supply kg 8,5 10,5 V-ph-Hz 230-1-50 230-1-50 Outdoor unit (HP) 009 012 Compressor Type Rotary Rotary Maximum pipe length m 10 10 Maximum height difference m 5 5 Chargeless m 5 5 dB(A)** 40 41 Sound pressure Sound power dB(A) 60 61 Dimensions (HxLxD) mm 535x700x235 540x780x250 Weight kg Flare Connections Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. Performances evaluated with 5m interconnecting tubes and according to EN14511. V-ph-Hz 28 35 1/4" - 3/8" 1/4" - 1/2" 230-1-50 230-1-50 IN Four products in one: dehumidifier, heater, air conditioner and fan. A product to use in every season. 42HQE_G FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42HQE_G Indoor unit Outdoor unit (HP) 42HQE_G - HIGH-WALL UNITS Allegro Plus is the friendly air-conditioner that refreshes in summer and provides warm in winter. The ideal companion throughout the years. CONTROLS 2 sizes heat pump from: 2,5 kW to 3,5 kW in cooling; 2,9 kW to 4,0 kW in heating. FEATURES Modern and trendy design thanks to its simple lines. Allegro Plus uses R410A, the no ozone depleting refrigerant for better performances. Programmable timer Easy to use remote control for a quick programming of well-being. The wide display gives a clear and precise view of the active setting. The active carbon filter eliminates bacteria and bad odours. Customised air flow thanks to the adjustable louvers. OUTDOOR UNITS The outdoor unit coils fins have been treated with blue-fin anti-corrosion coating. Outdoor unit the connections are protected by a protective shield; a feature not common in similar products.. VDE safety mark, worldwide recognised for reliability. All data are Eurovent certified. 38YE_G 56 57 42HQE_G - HIGH-WALL UNITS FIXED SPEED SPLIT SYSTEM 42HQE_G 42HQE009G 38YE009G 42HQE012G 38YE012G Cooling capacity (CO) kW 2,5 3,5 Power Input (CO) W 889 1245 W/W 2,81 2,81 E.E.R. Energy efficiency class (CO) C C 445 623 Annual Energy Consumption kWh Heating Capacity kW 2,9 4,0 Power Input (HP) W 903 1246 W/W 3,21 3,21 C C 009 012 C.O.P. Energy Efficiency Class (HP) Indoor unit Dehumidification l/h 1,0 1,2 Nominal air flow (l/m/h) l/s 97/110/125 105/130/178 Sound pressure (l/m/h) dB(A)* 33/36/39 32/35/42 Sound power (l/m/h) dB(A) 47/49/52 45/48/55 Dimensions (HxLxD) mm 250x750x188 280x815x195 Weight Power Supply kg 8,5 10,5 V-ph-Hz 230-1-50 230-1-50 Outdoor unit (HP) 009 012 Compressor Type Rotary Rotary Maximum pipe length m 10 10 Maximum height difference m 5 5 Chargeless m 5 5 dB(A)** 40 41 Sound pressure Sound power dB(A) 60 61 Dimensions (HxLxD) mm 535x700x235 540x780x250 Weight kg Flare Connections Power Supply * ** Sound pressure level in a free field according to JIS9612 Standard. Sound pressure level in emispheric field at 4 m. Performances evaluated with 5m interconnecting tubes and according to EN14511. V-ph-Hz 28 35 1/4" - 3/8" 1/4" - 1/2" 230-1-50 230-1-50 IN Four products in one: dehumidifier, heater, air conditioner and fan. A product to use in every season. 42HQE_G FIXED SPEED SPLIT SYSTEM FIXED SPEED SPLIT SYSTEM 42HQE_G Indoor unit Outdoor unit (HP) 42HQE_G - HIGH-WALL UNITS Allegro Plus is the friendly air-conditioner that refreshes in summer and provides warm in winter. The ideal companion throughout the years. CONTROLS 2 sizes heat pump from: 2,5 kW to 3,5 kW in cooling; 2,9 kW to 4,0 kW in heating. FEATURES Modern and trendy design thanks to its simple lines. Allegro Plus uses R410A, the no ozone depleting refrigerant for better performances. Programmable timer Easy to use remote control for a quick programming of well-being. The wide display gives a clear and precise view of the active setting. The active carbon filter eliminates bacteria and bad odours. Customised air flow thanks to the adjustable louvers. OUTDOOR UNITS The outdoor unit coils fins have been treated with blue-fin anti-corrosion coating. Outdoor unit the connections are protected by a protective shield; a feature not common in similar products.. VDE safety mark, worldwide recognised for reliability. All data are Eurovent certified. 38YE_G 56 57 73FC/XC/YC - WINDOW UNIT ROOM AIR CONDITIONERS 73Series XCY127DR XCP187DR kW 2,6 3,5 5,2 6,7 Power Input W 945 1200 2110 2720 W/W 2,75 2,92 2,46 2,46 C B D D 473 600 1055 1360 ROOM AIR CONDITIONERS 73FC/XC/YC EER Energy efficiency class Annual energy consumption Dehumidification l/h 0,7 1,6 2,4 3,3 Air flow* l/s 103 188 217 283 Dimensions (H x L x D) mm 330x600x470 425x640x610 425x640x610 445x712x600 Weight Power Supply * kWh YCN247DR kg 28 52 55 72 V-ph-Hz 220-1-50 220-1-50 220-1-50 220-1-50 SILENTIA High speed. Extremely quiet and very energy-efficient. 73FC/XC/YC ROOM AIR CONDITIONERS FCC097RB Cooling Capacity Model 73FC/XC/YC - WINDOW UNIT The new Carrier range features up-to-date design and superior energysaving performance. CONTROLS FEATURES Powerful, compact unit - 30% smaller than other comparable units. Uniform air distribution pattern and quiet operation make these units an obvious choice for optimum comfort day after day. Superior efficiency for ultimate comfort. Just four models covering most requirements up to 7 kW. All units are equipped with infrared remote control. COMPACT Powerful, compact unit. 30% smaller than other comparable units. 73FC 58 73XC/YC 59 73FC/XC/YC - WINDOW UNIT ROOM AIR CONDITIONERS 73Series XCY127DR XCP187DR kW 2,6 3,5 5,2 6,7 Power Input W 945 1200 2110 2720 W/W 2,75 2,92 2,46 2,46 C B D D 473 600 1055 1360 ROOM AIR CONDITIONERS 73FC/XC/YC EER Energy efficiency class Annual energy consumption Dehumidification l/h 0,7 1,6 2,4 3,3 Air flow* l/s 103 188 217 283 Dimensions (H x L x D) mm 330x600x470 425x640x610 425x640x610 445x712x600 Weight Power Supply * kWh YCN247DR kg 28 52 55 72 V-ph-Hz 220-1-50 220-1-50 220-1-50 220-1-50 SILENTIA High speed. Extremely quiet and very energy-efficient. 73FC/XC/YC ROOM AIR CONDITIONERS FCC097RB Cooling Capacity Model 73FC/XC/YC - WINDOW UNIT The new Carrier range features up-to-date design and superior energysaving performance. CONTROLS FEATURES Powerful, compact unit - 30% smaller than other comparable units. Uniform air distribution pattern and quiet operation make these units an obvious choice for optimum comfort day after day. Superior efficiency for ultimate comfort. Just four models covering most requirements up to 7 kW. All units are equipped with infrared remote control. COMPACT Powerful, compact unit. 30% smaller than other comparable units. 73FC 58 73XC/YC 59 51AKE / AKB / AKC - PORTABLES 51AKE / AKB / AKC 51AKE 065 51AKB 065 51AKB 085 51AKB 010 Cooling Capacity kW 1,71 1,71 2,1 2,6 3,35 Power Input W 630 630 820 850 1190 W/W 2,71 2,71 2,56 3,06 2,82 A A B B C 315 315 410 425 595 Indoor unit EER Energy class Annual energy consumption Dehumidification l/h 0,75 0,75 1,1 1,4 1,9 Air flow (l/h) l/s 75/90 75/90 75/90 133/104 133/104 Sound pressure level IU (l/h) dB(A) 46/48 46/48 46/48 46/43 46/43 Sound pressure level OU dB(A) - - - 50 50 Dimensions IU (H x L x D) mm 850x440x350 850x440x350 850x440x350 850x440x350 850x440x350 Weight IU kg 28 28 28,5 30 35 Dimensions OU (H x L x D) mm - - - 430x413x230 430x413x230 Weight OU kg - - - 11,5 11,5 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Air discharge tube, max. length mm 1100 1100 1100 - - Interconnecting Pipe Length mm - - - 1800 3600* A 3,2 3,2 4,4 4,4 5,8 Power Supply Electric heater current * kWh 51AKC 013 IN Three products in one: air conditioner, dehumidifier with easy-to-empty water tank and fan. A product for all seasons. with quick couplings. Performance data according to EN14511. 51AKE / AKB / AKC ROOM AIR CONDITIONERS ROOM AIR CONDITIONERS 51AKE / AKB / AKC ROOM AIR CONDITIONERS 51AKE / AKB / AKC - PORTABLES The portable Holiday units offer exceptional versatility combined with style to ensure optimum individual comfort in both residential rooms and single offices up to 40m. CONTROLS 51AKE FEATURES Practical and intuitive - the mechanical interface is easy to use. Small but powerful - small and light in weight, but very efficient at the same time. Up to 1.6 l/h dehumidification capacity. Condensate collected in an easy-toempty tank. 51AKB 51AKB/C ACCESSORIES Set of three porthole covers IAQ (indoor air quality) filter kit The energy consumption is much lower than that of a microwave oven or iron. Removing the condensate is no problem thanks to the removable tank; no pipes or sinks required. Split units are available with quick couplings for installation flexibility. Fully ecological - units use R-407C or R-410A refrigerant and have 100% recyclable packaging. CASTORS INCLUDED Monobloc and split versions - one of the smallest and lightest portable air conditioners on the market. 51 AKE 065 60 51AKB 065 51AKB 085 52AKB 010 53AKB 013 Easily movable from room to room with minimum effort. 61 51AKE / AKB / AKC - PORTABLES 51AKE / AKB / AKC 51AKE 065 51AKB 065 51AKB 085 51AKB 010 Cooling Capacity kW 1,71 1,71 2,1 2,6 3,35 Power Input W 630 630 820 850 1190 W/W 2,71 2,71 2,56 3,06 2,82 A A B B C 315 315 410 425 595 Indoor unit EER Energy class Annual energy consumption Dehumidification l/h 0,75 0,75 1,1 1,4 1,9 Air flow (l/h) l/s 75/90 75/90 75/90 133/104 133/104 Sound pressure level IU (l/h) dB(A) 46/48 46/48 46/48 46/43 46/43 Sound pressure level OU dB(A) - - - 50 50 Dimensions IU (H x L x D) mm 850x440x350 850x440x350 850x440x350 850x440x350 850x440x350 Weight IU kg 28 28 28,5 30 35 Dimensions OU (H x L x D) mm - - - 430x413x230 430x413x230 Weight OU kg - - - 11,5 11,5 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Air discharge tube, max. length mm 1100 1100 1100 - - Interconnecting Pipe Length mm - - - 1800 3600* A 3,2 3,2 4,4 4,4 5,8 Power Supply Electric heater current * kWh 51AKC 013 IN Three products in one: air conditioner, dehumidifier with easy-to-empty water tank and fan. A product for all seasons. with quick couplings. Performance data according to EN14511. 51AKE / AKB / AKC ROOM AIR CONDITIONERS ROOM AIR CONDITIONERS 51AKE / AKB / AKC ROOM AIR CONDITIONERS 51AKE / AKB / AKC - PORTABLES The portable Holiday units offer exceptional versatility combined with style to ensure optimum individual comfort in both residential rooms and single offices up to 40m. CONTROLS 51AKE FEATURES Practical and intuitive - the mechanical interface is easy to use. Small but powerful - small and light in weight, but very efficient at the same time. Up to 1.6 l/h dehumidification capacity. Condensate collected in an easy-toempty tank. 51AKB 51AKB/C ACCESSORIES Set of three porthole covers IAQ (indoor air quality) filter kit The energy consumption is much lower than that of a microwave oven or iron. Removing the condensate is no problem thanks to the removable tank; no pipes or sinks required. Split units are available with quick couplings for installation flexibility. Fully ecological - units use R-407C or R-410A refrigerant and have 100% recyclable packaging. CASTORS INCLUDED Monobloc and split versions - one of the smallest and lightest portable air conditioners on the market. 51 AKE 065 60 51AKB 065 51AKB 085 52AKB 010 53AKB 013 Easily movable from room to room with minimum effort. 61 51AKS - PORTABLES ROOM AIR CONDITIONERS 51AKS Portables 51AKS185 kW 2,1 2,1 2,6 2,6 3,35 3,35 3,35 3,77 Power Input W 820 820 850 850 1190 1190 1190 1500 W/W 2,56 2,56 3,06 3,06 2,82 2,82 2,82 2,51 B B B B C C C E 410 410 425 425 595 595 595 750 EER ROOM AIR CONDITIONERS 51AKS Energy class Annual energy consumption 51AKS113 51AKS015C-P Dehumidification l/h 1,1 1,1 1,4 1,4 1,9 1,9 1,9 2,7 Air flow (l/h) l/s 75/90 75/90 133/104 133/104 133/104 133/104 133/104 133/104 Sound pressure level IU (l/h) dB(A) 46/48 46/48 46/43 46/43 46/43 46/43 46/43 46/44 Sound pressure level OU dB(A) - - 50 50 50 50 50 50 Dimensions IU (H x L x D) mm 850x440x390 850x440x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 Weight IU kg 28,5 28,5 Dimensions OU (H x L x D) mm - - Weight OU 30,0 30,0 36 36 36 36 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 kg - - 11,5 11,5 11,5 11,5 11,5 11,5 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Air discharge tube, max. length mm 1100 1100 - - - - - - Interconnecting Pipe Length mm - - 1800 3600* 1800 3600* 1800 3600* Electric heater capacity Power Supply * kWh 51AKS010-P 51AKS010C-P 51AKS013-P 51AKS013C-P kW - 1,6 - - - - 1,6 - Current drawn (cooling mode) A 4,4 4,4 4,4 4,4 5,8 5,8 5,8 6,8 Current drawn (heating mode) A - 7,0 - - - - 7,0 - Up to four products in one: air conditioner, dehumidifier with removable water tank, fan and heater (see detail). A product for all four seasons. with quick couplings. Performance data according to EN14511. 51AKS ROOM AIR CONDITIONERS 51AKS085 Cooling Capacity Indoor unit 51AKS - PORTABLES The 51AKS is the elegant ready-to-use solution for use in different rooms at home or in the office. CONTROLS FEATURES 51AKS Electronic interface - advanced, immediate and intuitive technology allows easy and precise programming of personal comfort conditions. Choice of various capacity and colour combinations to suit all user requirements. Minimal noise levels for ultra-quiet operation, essential for total relaxation. ACCESSORIES Set of three porthole covers IAQ (indoor air quality) filter kit Sleep function - the lights are dimmed, fresh air is supplied at a soft whisper: ideal conditions for relaxed sleep and sweet dreams. Precise and powerful humidity control - with eight dehumidification levels and a removable tank, the split version removes up to 65 litres of water per day from the air. Extra compact and light - easy-to-move and not intrusive, blends in with any room surroundings. BENCHMARK Removing the condensate is no problem thanks to the removable tank; no pipes or sinks required. 51AKS 085 51AKS 185 62 51AKS 085-P 51AKS 085 AL 51AKS 010 P 51AKS 010 C-P 51AKS 013 P 51AKS 013 C-P 51AKS 015 C-P 51AKS 113 The smallest outdoor unit on the market 63 51AKS - PORTABLES ROOM AIR CONDITIONERS 51AKS Portables 51AKS185 kW 2,1 2,1 2,6 2,6 3,35 3,35 3,35 3,77 Power Input W 820 820 850 850 1190 1190 1190 1500 W/W 2,56 2,56 3,06 3,06 2,82 2,82 2,82 2,51 B B B B C C C E 410 410 425 425 595 595 595 750 EER ROOM AIR CONDITIONERS 51AKS Energy class Annual energy consumption 51AKS113 51AKS015C-P Dehumidification l/h 1,1 1,1 1,4 1,4 1,9 1,9 1,9 2,7 Air flow (l/h) l/s 75/90 75/90 133/104 133/104 133/104 133/104 133/104 133/104 Sound pressure level IU (l/h) dB(A) 46/48 46/48 46/43 46/43 46/43 46/43 46/43 46/44 Sound pressure level OU dB(A) - - 50 50 50 50 50 50 Dimensions IU (H x L x D) mm 850x440x390 850x440x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 Weight IU kg 28,5 28,5 Dimensions OU (H x L x D) mm - - Weight OU 30,0 30,0 36 36 36 36 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 kg - - 11,5 11,5 11,5 11,5 11,5 11,5 V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 Air discharge tube, max. length mm 1100 1100 - - - - - - Interconnecting Pipe Length mm - - 1800 3600* 1800 3600* 1800 3600* Electric heater capacity Power Supply * kWh 51AKS010-P 51AKS010C-P 51AKS013-P 51AKS013C-P kW - 1,6 - - - - 1,6 - Current drawn (cooling mode) A 4,4 4,4 4,4 4,4 5,8 5,8 5,8 6,8 Current drawn (heating mode) A - 7,0 - - - - 7,0 - Up to four products in one: air conditioner, dehumidifier with removable water tank, fan and heater (see detail). A product for all four seasons. with quick couplings. Performance data according to EN14511. 51AKS ROOM AIR CONDITIONERS 51AKS085 Cooling Capacity Indoor unit 51AKS - PORTABLES The 51AKS is the elegant ready-to-use solution for use in different rooms at home or in the office. CONTROLS FEATURES 51AKS Electronic interface - advanced, immediate and intuitive technology allows easy and precise programming of personal comfort conditions. Choice of various capacity and colour combinations to suit all user requirements. Minimal noise levels for ultra-quiet operation, essential for total relaxation. ACCESSORIES Set of three porthole covers IAQ (indoor air quality) filter kit Sleep function - the lights are dimmed, fresh air is supplied at a soft whisper: ideal conditions for relaxed sleep and sweet dreams. Precise and powerful humidity control - with eight dehumidification levels and a removable tank, the split version removes up to 65 litres of water per day from the air. Extra compact and light - easy-to-move and not intrusive, blends in with any room surroundings. BENCHMARK Removing the condensate is no problem thanks to the removable tank; no pipes or sinks required. 51AKS 085 51AKS 185 62 51AKS 085-P 51AKS 085 AL 51AKS 010 P 51AKS 010 C-P 51AKS 013 P 51AKS 013 C-P 51AKS 015 C-P 51AKS 113 The smallest outdoor unit on the market 63 54DHS - DEHUMIDIFIERS ROOM AIR CONDITIONERS 54DHS Dehumidifiers Carrier model n° 54DHS014 54DHS018 54DHS018HE lt 11 14 18 18 24 Power consumption a 27°C, 60% RH W 205 232 410 410 410 1 2 2 2 2 m3/h 100 110 160 160 180 lt 7 Fan speeds ROOM AIR CONDITIONERS 54DHS Air flow Tank capacity 54DHS024 6 6 7 7 Deodorizing filters – Yes – – – Antibacterial filters – – Yes Yes Yes Electric heater – – – Yes – Continuos drain hose connection W Yes Yes Yes Yes Yes Container full light and auto shut off Yes Yes Yes Yes Yes Defrost Yes Yes Yes Yes Yes Electronic humidistat Yes Yes Yes Yes Yes Digital control – – – Yes Yes Castors Yes Yes Yes Yes Yes Transporting handle Yes Yes Yes Yes Yes °C 5-35 5-35 5-35 5-35 5-35 R134A R134A R134A R134A R134A Size (W x H x D) mm 325x540x355 325x540x355 345x722x352 345x722x352 345x722x352 Weight kg 15 15,5 19,5 19,5 22 Working limits Refrigerant °C The new “Comfort dehumidifyng” function selects automatically the right level of humidity in relative to temperature variations. (Idealday 24) 54DHS ROOM AIR CONDITIONERS 54DHS011 Capacity *tested by EU directive CEE 73/23/CE 54DHS - DEHUMIDIFIERS Idealday is the name, as these units offer the ideal solution for excess humidity removal from your environment, preserving walls, furniture and your health. FEATURES WHY IS IT SO IMPORTANT TO CONTROL THE HUMIDITY LEVEL? Too much humidity damages your health and the furniture in the house. It harms people, aggravating conditions like asthma, arthritis and rheumatism. High humidity levels cause mould on the walls and damps patches, and spool surfaces. Humidity should be controlled all year long, especially in rainy autumns and in humid summers. CONTROLS 54DHS11 54DHS14 Special antibacterial filter to prevent growth of bacteria and form of mould for purer and healthier environments. (Idealday 24 and 18HE) Electronic control with multifunctional liquid crystal display with clock and timer function for a precise regulation of the humidity level. (Idealday 24 and 18HE) 2 in 1 air purifier and dehumidifier. The two functions can be used also indipendently. (Idealday 14) 54DHS18 Large-capacity tank positioned on the front of the product for easy removal. The dehumidifier stops automatically when the tank is full. Version available with heater (800W) to speed up humidity absorption, giving you a pleasant sensation of warmth. (Idealday 18HE). 54DHS18HE 54DHS24 Silent and light with integrated wheels. 2 speed turbo ventilator to quickly activate the set value. ACCESSORIES Connect up to the continuous flow condensation waste pipe if required. All models use refrigerant without CFC/H-CFC to avoid ozone depleting. 54DHS18 54DHS18HE 54DHS24 ZO N E D EP R RIE R TIO N R-134a CA 64 LE ZERO O 54DHS11 54DHS14 54DHS 9000: set of three replacement carbon filters 65 54DHS - DEHUMIDIFIERS ROOM AIR CONDITIONERS 54DHS Dehumidifiers Carrier model n° 54DHS014 54DHS018 54DHS018HE lt 11 14 18 18 24 Power consumption a 27°C, 60% RH W 205 232 410 410 410 1 2 2 2 2 m3/h 100 110 160 160 180 lt 7 Fan speeds ROOM AIR CONDITIONERS 54DHS Air flow Tank capacity 54DHS024 6 6 7 7 Deodorizing filters – Yes – – – Antibacterial filters – – Yes Yes Yes Electric heater – – – Yes – Continuos drain hose connection W Yes Yes Yes Yes Yes Container full light and auto shut off Yes Yes Yes Yes Yes Defrost Yes Yes Yes Yes Yes Electronic humidistat Yes Yes Yes Yes Yes Digital control – – – Yes Yes Castors Yes Yes Yes Yes Yes Transporting handle Yes Yes Yes Yes Yes °C 5-35 5-35 5-35 5-35 5-35 R134A R134A R134A R134A R134A Size (W x H x D) mm 325x540x355 325x540x355 345x722x352 345x722x352 345x722x352 Weight kg 15 15,5 19,5 19,5 22 Working limits Refrigerant °C The new “Comfort dehumidifyng” function selects automatically the right level of humidity in relative to temperature variations. (Idealday 24) 54DHS ROOM AIR CONDITIONERS 54DHS011 Capacity *tested by EU directive CEE 73/23/CE 54DHS - DEHUMIDIFIERS Idealday is the name, as these units offer the ideal solution for excess humidity removal from your environment, preserving walls, furniture and your health. FEATURES WHY IS IT SO IMPORTANT TO CONTROL THE HUMIDITY LEVEL? Too much humidity damages your health and the furniture in the house. It harms people, aggravating conditions like asthma, arthritis and rheumatism. High humidity levels cause mould on the walls and damps patches, and spool surfaces. Humidity should be controlled all year long, especially in rainy autumns and in humid summers. CONTROLS 54DHS11 54DHS14 Special antibacterial filter to prevent growth of bacteria and form of mould for purer and healthier environments. (Idealday 24 and 18HE) Electronic control with multifunctional liquid crystal display with clock and timer function for a precise regulation of the humidity level. (Idealday 24 and 18HE) 2 in 1 air purifier and dehumidifier. The two functions can be used also indipendently. (Idealday 14) 54DHS18 Large-capacity tank positioned on the front of the product for easy removal. The dehumidifier stops automatically when the tank is full. Version available with heater (800W) to speed up humidity absorption, giving you a pleasant sensation of warmth. (Idealday 18HE). 54DHS18HE 54DHS24 Silent and light with integrated wheels. 2 speed turbo ventilator to quickly activate the set value. ACCESSORIES Connect up to the continuous flow condensation waste pipe if required. All models use refrigerant without CFC/H-CFC to avoid ozone depleting. 54DHS18 54DHS18HE 54DHS24 ZO N E D EP R RIE R TIO N R-134a CA 64 LE ZERO O 54DHS11 54DHS14 54DHS 9000: set of three replacement carbon filters 65