Air conditioning solutions

Transcription

Air conditioning solutions
C0002-06_GEN06
2006
Air conditioning solutions
Residential and Light Commercial Systems
SOLUTIONS FOR A FRESHER WORLD ™
INDEX
INVERTER SPEED SYSTEMS
42PQV_S
42HQV
42PQV_lc
42VQV
40KQV
40DQV
38VYX
38VGM
18 - 19
20 - 21
22 - 23
24 - 25
26 - 27
28 - 29
30 - 31
32 - 33
FIXED SPEED SYSTEM
42PHQ_S
42PHQ_A
42VMC_N
40KMC_N
40SMC_N
40DMC
FB4X
38GLM/YYM
34 - 35
36 - 37
38 - 39
40 - 41
42 - 43
44 - 45
46 - 47
48 - 53
DX CONTROLS
DX CONTROLS
54 - 55
FIXED SPEED SYSTEM
42HQE
56 - 57
ROOM AIR CONDITIONERS
73FC/XC/YC
51AKA/B/C
51AKS
54DHS
58 - 59
60 - 61
62 - 63
64 - 65
Our mission is to make he world a better place to live. A
For our commitment in developing products for a safer,
mission that was born more than one hundred years ago
cleaner and less polluted planet we received the presti-
when Willis Carrier invented the basics of modern air con-
gious
ditioning and developed the first air conditioning system.
Environmental Protection Agency (EPA). Every day around
Since then we have created a confortable, productive and
the world a Carrier system is installed every eight
healthy environment, regardless of climate, and we have
seconds, and we are now the world’s largest manufacturer
ensured that the global food supply is transported and
of air conditioning, ventilation, heating and commercial
preserved for safe consumption.
refrigeration system.
Our dedication to enhance our environment also means
preserving the environment for everybody.
Carrier was the first air conditioning manufacturer to use
chlorine-free refrigerants that do not deplete the ozone
layer.
SOLUTIONS FOR A FRESHER WORLD
Ozone
Protection
Award
from
the
U.S.
Carrier is a member of the United Technologies Corporation
(UTC) which employs 205,700 people, operates in more than
180 countries, and is the 51st largest corporation in the
United States. The UTC group is a global technology corporation with a long history of a pioneering innovation in aerospace, aviaton, helicopter design, climate control, elevator
design and hydrogen fuel cells.
Supported by leadership of UTC, Carrier is a source of ideas,
technologies and innovation to help buid a better world.
CARRIER EXPE RIENCE BACKED BY A LARGE GROUP
The world's largest manu-
The experts in electronic
The world's largest manu-
The innovators in hydro-
facturer of air conditio-
security systems, fire pro-
facturer
gen-powered fuel cells for
ning, ventilation and refri-
tection systems and secu-
escalators
geration systems
rity system monitoring
walkways
of
elevators,
and
moving
space, commercial transport
and
applications.
The leading supplier
The specialists in com-
The world leader inthe
of aerospace systemsand
mercial and military air-
design and manufacture of
components, fueand spe-
craft engines and space
helicopters for commer-
cial fluid pumps, and pro-
propulsion systems
cial, industrial and milita-
pellerand engine control
systems
ry use.
residential
Carrier is a member of the United Technologies Corporation
(UTC) which employs 205,700 people, operates in more than
180 countries, and is the 51st largest corporation in the
United States. The UTC group is a global technology corporation with a long history of a pioneering innovation in aerospace, aviaton, helicopter design, climate control, elevator
design and hydrogen fuel cells.
Supported by leadership of UTC, Carrier is a source of ideas,
technologies and innovation to help buid a better world.
CARRIER EXPE RIENCE BACKED BY A LARGE GROUP
The world's largest manu-
The experts in electronic
The world's largest manu-
The innovators in hydro-
facturer of air conditio-
security systems, fire pro-
facturer
gen-powered fuel cells for
ning, ventilation and refri-
tection systems and secu-
escalators
geration systems
rity system monitoring
walkways
of
elevators,
and
moving
space, commercial transport
and
applications.
The leading supplier
The specialists in com-
The world leader inthe
of aerospace systemsand
mercial and military air-
design and manufacture of
components, fueand spe-
craft engines and space
helicopters for commer-
cial fluid pumps, and pro-
propulsion systems
cial, industrial and milita-
pellerand engine control
systems
ry use.
residential
Michelangelo's frescos, the Alexandrian manuscripts and the
works of art in the British Museum can be admired thanks to
Carrier. Carrier air and climate quality control systems are
chosen to protect the most prestigious buildings in the
world, supported by the know-how and expertise of a company with over 100 years of experience and continuous innovation. The Carrier brand is renowned as a reliable partner
for any application.
YOUR PARTNER FOR GREAT CHALLENGES
Alexandria Library
Suntek City Singapore
Carrier has supplied the climate control system that protects
New British Museum London
The world biggest telescope.
Cerro La Silla - Chile
and monitors the Sistine Chapel 24 hours a day.
Queen Mary II
Epcot Center Florida
Michelangelo's frescos, the Alexandrian manuscripts and the
works of art in the British Museum can be admired thanks to
Carrier. Carrier air and climate quality control systems are
chosen to protect the most prestigious buildings in the
world, supported by the know-how and expertise of a company with over 100 years of experience and continuous innovation. The Carrier brand is renowned as a reliable partner
for any application.
YOUR PARTNER FOR GREAT CHALLENGES
Alexandria Library
Suntek City Singapore
Carrier has supplied the climate control system that protects
New British Museum London
The world biggest telescope.
Cerro La Silla - Chile
and monitors the Sistine Chapel 24 hours a day.
Queen Mary II
Epcot Center Florida
Carrier is the largest organisation world-wide committed to
development and research in air conditioning. A great innovative force that continuously sets new standards in comfort,
efficiency and installation flexibility. Satellite, the innovatiSatellite detail V-shaped coil
ve Carrier ductable system that has completely revolutionised previous market standards, that were of course also set
by Carrier. Designed together by the best professionals, and
destined to become the absolute new industry standard.
RESEARCH + EXPE RIENCE = INNOVATIVE SOLUTION
The technical experts unveil a new standard of working - simple,
clean, flexible, efficient - leaving customers completely satisfied
Carrier is the largest organisation world-wide committed to
development and research in air conditioning. A great innovative force that continuously sets new standards in comfort,
efficiency and installation flexibility. Satellite, the innovatiSatellite detail V-shaped coil
ve Carrier ductable system that has completely revolutionised previous market standards, that were of course also set
by Carrier. Designed together by the best professionals, and
destined to become the absolute new industry standard.
RESEARCH + EXPE RIENCE = INNOVATIVE SOLUTION
The technical experts unveil a new standard of working - simple,
clean, flexible, efficient - leaving customers completely satisfied
The air quality in closed rooms can be 10 times more polluted than the outdoor air. To offer more breathable air,
Carrier has developed Air4Life, an efficient four-stage air
filtration system, based on titanium-dioxide technology to
make the air cleaner and healthier. To recreate the same
pleasant sensation of well-being that exists near a waterfall or in a forest in your own home, Carrier air conditioners include ionisers, to make the air more pleasant and
healthier to breathe.
HEALTHY AIR FOR ENHANCED WELL-BEING
The exclusive four-stage Air4Life filtration system makes the
The same pleasant sensation of well-being that can be
Negative ions assist the elimination of serotonin from the
air healthier and cleaner, significantly reducing pollutants,
found in a forest or in the mountains can now be achieved
blood, providing vigour and energy and increasing concen-
pollen and
in your own home with the Carrier ioniser. It enriches the
tration. With their relaxing effect they are a valuable aid
air with negative ions to provide vitality and energy.
against daily stress.
allergens.
The air quality in closed rooms can be 10 times more polluted than the outdoor air. To offer more breathable air,
Carrier has developed Air4Life, an efficient four-stage air
filtration system, based on titanium-dioxide technology to
make the air cleaner and healthier. To recreate the same
pleasant sensation of well-being that exists near a waterfall or in a forest in your own home, Carrier air conditioners include ionisers, to make the air more pleasant and
healthier to breathe.
HEALTHY AIR FOR ENHANCED WELL-BEING
The exclusive four-stage Air4Life filtration system makes the
The same pleasant sensation of well-being that can be
Negative ions assist the elimination of serotonin from the
air healthier and cleaner, significantly reducing pollutants,
found in a forest or in the mountains can now be achieved
blood, providing vigour and energy and increasing concen-
pollen and
in your own home with the Carrier ioniser. It enriches the
tration. With their relaxing effect they are a valuable aid
air with negative ions to provide vitality and energy.
against daily stress.
allergens.
Carrier quality and reliability are incorporated and
guaranteed in all products and systems. They are submitted
to extensive tests before they are shipped to the customers,
such as a 10-minute system operating test. They are also
certified by the major international organisations to guarantee authenticity of the information supplied, safety of the
products and high process applications standards. All this
means that the customer will receive a safe and reliable
product.
RELIABILITY
INCLUDED
Performance Eurovent guarantee
Safety for the customer
ISO 9001:2000 process certification
Carrier has participated in the Eurovent certification program-
In addition to the CE marking, the absolute safety of
All Carrier processes are certified in accordance
me from the very beginning. Eurovent tests the products and
Carrier products is certified and guaranteed by the presti-
with the quality management system standard ISO
verifies the conformance between test results and product.
gious independent performance data published by the
9001:2000 to assure the customer that products
manufacturer.
and services conform with the policies of the Carrier
organisation
organisations.
IMQ
agency
or
other
equivalent
Carrier quality and reliability are incorporated and
guaranteed in all products and systems. They are submitted
to extensive tests before they are shipped to the customers,
such as a 10-minute system operating test. They are also
certified by the major international organisations to guarantee authenticity of the information supplied, safety of the
products and high process applications standards. All this
means that the customer will receive a safe and reliable
product.
RELIABILITY
INCLUDED
Performance Eurovent guarantee
Safety for the customer
ISO 9001:2000 process certification
Carrier has participated in the Eurovent certification program-
In addition to the CE marking, the absolute safety of
All Carrier processes are certified in accordance
me from the very beginning. Eurovent tests the products and
Carrier products is certified and guaranteed by the presti-
with the quality management system standard ISO
verifies the conformance between test results and product.
gious independent performance data published by the
9001:2000 to assure the customer that products
manufacturer.
and services conform with the policies of the Carrier
organisation
organisations.
IMQ
agency
or
other
equivalent
Today potential and existing residential and light commercial
air conditioning customers are very demanding. They have
many differing expectations and varying profiles. The Carrier
product range will provide them all with the ideal solution for
their individual functional, aesthetic and economical requirements and their personal preference. They will all have the
peaceof-mind of having chosen the world's leading industry
expert. Carrier has a differentiated product range that also
benefits our partners who can now personalise their offer for
their own customer base.
PERSONALIZED
“Absolute well-being”
AIR CONDITIONING
“Superior comfort”
“Comfort at close hand”
Today potential and existing residential and light commercial
air conditioning customers are very demanding. They have
many differing expectations and varying profiles. The Carrier
product range will provide them all with the ideal solution for
their individual functional, aesthetic and economical requirements and their personal preference. They will all have the
peaceof-mind of having chosen the world's leading industry
expert. Carrier has a differentiated product range that also
benefits our partners who can now personalise their offer for
their own customer base.
PERSONALIZED
“Absolute well-being”
AIR CONDITIONING
“Superior comfort”
“Comfort at close hand”
42PQV_S - HI-WALL UNIT
INVERTER SPLIT SYSTEM
Indoor unit
42PQV009S
42PQV012S
Outdoor unit (HP)
38VBH009S
38VBH012S
Nominal cooling capacity
kW
2,60
3,50
Minimum cooling capacity
kW
1,40
1,80
Maximum cooling capacity
kW
3,30
4,00
Nominal power input
W
810
1163
Minimum power input
W
420
537
Maximum power input
W
1467
1818
W/W
3,21
3,01
EER
Energy efficiency class (CO)
A
B
Annual energy consumption
kWh
405
582
Nominal heating capacity
kW
3,20
4,00
Minimum heating capacity
kW
1,50
1,90
Maximum heating capacity
kW
4,0
5,1
Nominal power input
W
928
1246
Minimum power input
W
395
506
Maximum power input
W
1550
2100
W/W
3,45
3,21
B
C
COP
Energy efficiency class (HP)
Indoor unit
Dehumidification
Air flow (l/m/h)
09
12
l/h
1,1
1,3
l/s
114/135/155
124/141/161
Sound pressure (l/m/h)
dB(A)*
33/36/39
35/37/40
Sound power (l/m/h)
dB(A)
46/49/52
48/50/53
Dimensions (HxLxD)
mm
260x790x196
260x790x196
Weight
kg
8,6
8,6
V-ph-Hz
220/240-1-50/60
220/240-1-50/60
Power Supply
Outdoor unit (HP)
09
12
Compressor Type
rotary
rotary
Maximum pipe length
m
10
15
Maximum height difference
m
8
10
Chargeless pipe length
Air flow
Sound pressure
Sound power
m
10
15
m3/h
605 - 1690
580 - 1550
dB(A)**
41
41
dB(A)
61
61
Dimensions (HxLxD)
mm
590 x 750 x 280
590 x 750 x 280
Weight
kg
33
37
inch
3/8 - 1/4
1/2 - 1/4
A
7
11
V-ph-Hz
220/240-1-50/60
220/240-1-50/60
Flare Connections
Starting current
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4m.
42PQV_S INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40PQV_S
42PQV_S Inverter hi-wall
Class A efficiency - the ultimate evolution of
comfort with maximised savings thanks to the
XPower inverter technology.
42PQV_S - HI-WALL UNIT
The elegant slim-line XPower Sensat-ion will create a feeling of optimal
well-being and vitality and blend with any room decoration.
CONTROLS
2 sizes in cooling only and heat pump capacities from: 2,6kW to 3,5kW in cooling; 3,2kW
to 4,0kW in heating.
FEATURES
Extra Power, Ionizer and Eco function
A perfect combination of ions and micro-filtered air. This way the air in your
home is always clean and energised.
The start-up speed of the XPower system provides you with maximum comfort
in half the time compared to traditional systems.
Constant comfort. As the temperature approaches the preset level, XPower
gradually reduces the compressor speed.
All Sensat-ion models are in Satin finish aluminium, high quality and un-matched style.
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.
EXCLUSIVE 4 STAGE FILTRATION SYSTEM. 1.anti-bacteria pre filter; 2.electrostatic filter; 3.photo catalyst re-generable filter;4.anti-bacteria fan and drain
pan.
Thanks to the new air management system and to the Inverter technology the
noise is reduced to a whisper.
OUTDOOR UNITS
ANTI CORROSION PROTECTION. Plastic case condensing unit; compact and
light. UV light resistant.
Monosplit: 38VBH_S
18
19
42PQV_S - HI-WALL UNIT
INVERTER SPLIT SYSTEM
Indoor unit
42PQV009S
42PQV012S
Outdoor unit (HP)
38VBH009S
38VBH012S
Nominal cooling capacity
kW
2,60
3,50
Minimum cooling capacity
kW
1,40
1,80
Maximum cooling capacity
kW
3,30
4,00
Nominal power input
W
810
1163
Minimum power input
W
420
537
Maximum power input
W
1467
1818
W/W
3,21
3,01
EER
Energy efficiency class (CO)
A
B
Annual energy consumption
kWh
405
582
Nominal heating capacity
kW
3,20
4,00
Minimum heating capacity
kW
1,50
1,90
Maximum heating capacity
kW
4,0
5,1
Nominal power input
W
928
1246
Minimum power input
W
395
506
Maximum power input
W
1550
2100
W/W
3,45
3,21
B
C
COP
Energy efficiency class (HP)
Indoor unit
Dehumidification
Air flow (l/m/h)
09
12
l/h
1,1
1,3
l/s
114/135/155
124/141/161
Sound pressure (l/m/h)
dB(A)*
33/36/39
35/37/40
Sound power (l/m/h)
dB(A)
46/49/52
48/50/53
Dimensions (HxLxD)
mm
260x790x196
260x790x196
Weight
kg
8,6
8,6
V-ph-Hz
220/240-1-50/60
220/240-1-50/60
Power Supply
Outdoor unit (HP)
09
12
Compressor Type
rotary
rotary
Maximum pipe length
m
10
15
Maximum height difference
m
8
10
Chargeless pipe length
Air flow
Sound pressure
Sound power
m
10
15
m3/h
605 - 1690
580 - 1550
dB(A)**
41
41
dB(A)
61
61
Dimensions (HxLxD)
mm
590 x 750 x 280
590 x 750 x 280
Weight
kg
33
37
inch
3/8 - 1/4
1/2 - 1/4
A
7
11
V-ph-Hz
220/240-1-50/60
220/240-1-50/60
Flare Connections
Starting current
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4m.
42PQV_S INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40PQV_S
42PQV_S Inverter hi-wall
Class A efficiency - the ultimate evolution of
comfort with maximised savings thanks to the
XPower inverter technology.
42PQV_S - HI-WALL UNIT
The elegant slim-line XPower Sensat-ion will create a feeling of optimal
well-being and vitality and blend with any room decoration.
CONTROLS
2 sizes in cooling only and heat pump capacities from: 2,6kW to 3,5kW in cooling; 3,2kW
to 4,0kW in heating.
FEATURES
Extra Power, Ionizer and Eco function
A perfect combination of ions and micro-filtered air. This way the air in your
home is always clean and energised.
The start-up speed of the XPower system provides you with maximum comfort
in half the time compared to traditional systems.
Constant comfort. As the temperature approaches the preset level, XPower
gradually reduces the compressor speed.
All Sensat-ion models are in Satin finish aluminium, high quality and un-matched style.
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.
EXCLUSIVE 4 STAGE FILTRATION SYSTEM. 1.anti-bacteria pre filter; 2.electrostatic filter; 3.photo catalyst re-generable filter;4.anti-bacteria fan and drain
pan.
Thanks to the new air management system and to the Inverter technology the
noise is reduced to a whisper.
OUTDOOR UNITS
ANTI CORROSION PROTECTION. Plastic case condensing unit; compact and
light. UV light resistant.
Monosplit: 38VBH_S
18
19
42HQV_R - HI-WALL UNITS
INVERTER SPLIT SYSTEM
Indoor unit
42HQV025R
42HQV035R
42HQV045R
Outdoor unit HP
38VYX025R
38VYX035R
38VYX045R
Nominal cooling capacity
kW
2,50
3,50
4,62
Minimum cooling capacity
kW
0,90
1,10
1,20
Maximum cooling capacity
kW
3,00
4,00
5,10
Nominal power input
W
780
1090
1630
Minimum power input
W
260
200
260
Maximum power input
W
990
1330
1930
3,21
3,21
2,83
A
A
C
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
390
545
815
Nominal heating capacity
kW
3,20
4,20
5,90
Minimum heating capacity
kW
0,90
1,10
1,30
Maximum heating capacity
kW
4,00
5,80
7,40
Nominal power input
W
870
1150
1760
Minimum power input
W
210
200
270
Maximum power input
W
1160
1670
2360
3,68
3,65
3,35
A
A
C
COP
Energy efficiency class (HP)
Indoor unit
Deumidification
Air flow (l/m/h)
25
35
45
l/h
1,5
2,0
2,1
l/s
95/125/147
95/125/147
145/179/212
Sound pressure level (l/m/h)
dB(A)*
29/35/39
28/34/39
34/40/45
Sound power level (l/m/h)
dB(A)
42/48/52
41/47/52
47/53/58
Dimensions (H x L x D)
mm
275 x 790 x 208
275 x 790 x 208
275 x 790 x 208
Weight
kg
10
10
10
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
25
35
45
Maximum pipe length
m
10
15
15
Vertical height difference
m
Power Supply
Outdoor unit (HP)
8
10
10
Rotary
Rotary
Twin Rrotary
m
10
15
15
dB(A)**
40
43
44
Compressor Type
Chargeless
Sound pressure level (l/m/h)
Sound power level (l/m/h)
dB(A)
60
63
64
Dimensions (H x L x D)
mm
530 x 660 x 240
550 x 780 x 270
550 x 780 x 270
Weight
kg
30
36
39
Flare Connections
Power Supply
*
**
inch
3/8" - 1/4"
3/8" - 1/4"
1/2" - 1/4"
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
Sound Pressure level at 1,5m distance from indoor unit.
Sound Pressure level at 1m distance from outdoor unit.
The Nano Technology
Nano technology increases the filtering capacity, improving the performance of the filters, by reducing the normal filter components size
into nano-size or crystal forms. This process makes Nano filters more effective than standard ones.
42HQV_R INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 42HQV_R
42HQV_R DC Inverter Hi-wall
A efficiency class in cooling and heating thanks
to the advanced XPower DC Inverter technology.
42HQV_R - HIGH-WALL
SilenTECH is the ultimate evolution of comfort with its low noise level and
its maximum energy savings.
3 sizes heat pump; capacities from 2,5kW to 4,62kW in cooling and from 3,2 kW to 5,9
kW in heating.
FEATURES
The new XPower DC Inverter technology allows to reach quickly the optimal
well-being with the maximum energy savings.
Unique combined action of PAM and PWM
control.
CONTROLS
Exclusive air purification system: the new Nano-Photo Copper and the new
Nano-Silver-Gingsen filters are the most powerful solution to eliminate bacteria
and deodorize the air.
Thanks to the XPower DC Inverter technology the sound is light like a feather.
The start-up speed of the XPower system provides the maximum comfort in
half the time compared to a traditional system.
Unique combined action of PAM & PWM controls:
- PAM (Pulse Amplitude Modulation) generates maximum power at start-up
- PWM (Pulse Width Modulation) optimises the efficiency once the ideal tem
perature has been reached.
Extra power & Eco function
OUTDOOR UNITS
The ancient benefits of Gingseng
Ginseng is known to lower cholesterol, to balance the metabolism, to increase energy levels, and to stimulate the immune system.
It is also used to alleviate fatigue and to reduce stress on the body. It increases cells and tissues oxygenation, promoting detoxification and stimulating the regeneration of damaged cells.
Monosplit: 38VYX_R
20
21
42HQV_R - HI-WALL UNITS
INVERTER SPLIT SYSTEM
Indoor unit
42HQV025R
42HQV035R
42HQV045R
Outdoor unit HP
38VYX025R
38VYX035R
38VYX045R
Nominal cooling capacity
kW
2,50
3,50
4,62
Minimum cooling capacity
kW
0,90
1,10
1,20
Maximum cooling capacity
kW
3,00
4,00
5,10
Nominal power input
W
780
1090
1630
Minimum power input
W
260
200
260
Maximum power input
W
990
1330
1930
3,21
3,21
2,83
A
A
C
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
390
545
815
Nominal heating capacity
kW
3,20
4,20
5,90
Minimum heating capacity
kW
0,90
1,10
1,30
Maximum heating capacity
kW
4,00
5,80
7,40
Nominal power input
W
870
1150
1760
Minimum power input
W
210
200
270
Maximum power input
W
1160
1670
2360
3,68
3,65
3,35
A
A
C
COP
Energy efficiency class (HP)
Indoor unit
Deumidification
Air flow (l/m/h)
25
35
45
l/h
1,5
2,0
2,1
l/s
95/125/147
95/125/147
145/179/212
Sound pressure level (l/m/h)
dB(A)*
29/35/39
28/34/39
34/40/45
Sound power level (l/m/h)
dB(A)
42/48/52
41/47/52
47/53/58
Dimensions (H x L x D)
mm
275 x 790 x 208
275 x 790 x 208
275 x 790 x 208
Weight
kg
10
10
10
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
25
35
45
Maximum pipe length
m
10
15
15
Vertical height difference
m
Power Supply
Outdoor unit (HP)
8
10
10
Rotary
Rotary
Twin Rrotary
m
10
15
15
dB(A)**
40
43
44
Compressor Type
Chargeless
Sound pressure level (l/m/h)
Sound power level (l/m/h)
dB(A)
60
63
64
Dimensions (H x L x D)
mm
530 x 660 x 240
550 x 780 x 270
550 x 780 x 270
Weight
kg
30
36
39
Flare Connections
Power Supply
*
**
inch
3/8" - 1/4"
3/8" - 1/4"
1/2" - 1/4"
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
Sound Pressure level at 1,5m distance from indoor unit.
Sound Pressure level at 1m distance from outdoor unit.
The Nano Technology
Nano technology increases the filtering capacity, improving the performance of the filters, by reducing the normal filter components size
into nano-size or crystal forms. This process makes Nano filters more effective than standard ones.
42HQV_R INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 42HQV_R
42HQV_R DC Inverter Hi-wall
A efficiency class in cooling and heating thanks
to the advanced XPower DC Inverter technology.
42HQV_R - HIGH-WALL
SilenTECH is the ultimate evolution of comfort with its low noise level and
its maximum energy savings.
3 sizes heat pump; capacities from 2,5kW to 4,62kW in cooling and from 3,2 kW to 5,9
kW in heating.
FEATURES
The new XPower DC Inverter technology allows to reach quickly the optimal
well-being with the maximum energy savings.
Unique combined action of PAM and PWM
control.
CONTROLS
Exclusive air purification system: the new Nano-Photo Copper and the new
Nano-Silver-Gingsen filters are the most powerful solution to eliminate bacteria
and deodorize the air.
Thanks to the XPower DC Inverter technology the sound is light like a feather.
The start-up speed of the XPower system provides the maximum comfort in
half the time compared to a traditional system.
Unique combined action of PAM & PWM controls:
- PAM (Pulse Amplitude Modulation) generates maximum power at start-up
- PWM (Pulse Width Modulation) optimises the efficiency once the ideal tem
perature has been reached.
Extra power & Eco function
OUTDOOR UNITS
The ancient benefits of Gingseng
Ginseng is known to lower cholesterol, to balance the metabolism, to increase energy levels, and to stimulate the immune system.
It is also used to alleviate fatigue and to reduce stress on the body. It increases cells and tissues oxygenation, promoting detoxification and stimulating the regeneration of damaged cells.
Monosplit: 38VYX_R
20
21
42PQV_S LC - HI-WALL UNIT
INVERTER SPLIT SYSTEM
Indoor unit
42PQV050S
42PQV080S
42PQV110S
Outdoor unit HP
38VYX050N
38VYX080N
38VYX110N
9,20
Nominal cooling capacity
kW
4,80
6,50
Minimum cooling capacity
kW
1,00
2,10
2,20
Maximum cooling capacity
kW
5,25
7,00
11,00
W
1780
2490
3333
W/W
2,70
2,61
2,76
D
D
D
kW
890
1245
1667
Nominal power input
EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%
W/W (1)
4,30
4,20
4,80
Nominal heating capacity
kW
5,25
7,60
10,10
Minimum heating capacity
kW
0,90
1,70
2,20
Maximum heating capacity
kW
6,50
7,94
12,5
Nominal power input
W
1540
2750
2962
W/W
3,41
2,76
3,41
B
E
B
5,20
4,00
5,10
050
080
110
COP
Energy efficiency class (HP)
COP 50%
W/W (1)
Indoor unit
Deumidification
l/h
1,8
2,0
2,1
Nominal air flow (low/med/high)
l/s
160/200/230
95/125/147
145/179/212
Sound pressure (low/med/high) (CO)
dB(A)*
36/40/43
28/34/39
34/40/45
Sound power (low/med/high) (CO)
dB(A)
49/53/56
41/47/52
47/53/58
Sound pressure (low/med/high) (HP)
dB(A)*
34/38/41
275 x 790 x 208
275 x 790 x 208
Sound power (low/med/high) (HP)
dB(A)
47/51/54
10
10
Dimensions (H x L x D)
mm
285x1080x200
285x1080x200
446x546x356
Weight
kg
14
14
23
V-Ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
Power supply
Outdoor unit (HP)
050
080
110
Compressor Type
Twin Rotary
Twin Rotary
Twin Rotary
Maximum pipe lenght
m
30
50
50
Maximum height difference
m
30
30 (15)
30 (15)
Chargeless pipe lenght
m
20
20
20
m3/h
290/665
290/110
nd/2085
dB(A)**
43
45
51
Air Flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
dB(A)
63
65
71
dB(A)**
45
47
51
dB(A)
65
67
71
Dimensions (H x L x D)
mm
595x780x270
795x900x320
1340x900x320
Weight
kg
35
55
75
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
Sound pressure (HP)
Sound power (HP)
Flare connections
Starting current
Power supply
A
12
15
22
V-Ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
42PQV_S LC INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40PQV_S LC
42PQV_S LC - HI-WALL UNIT
DC Blended Inverter Technology: more comfort
and effective cost savings.
42PQV_S LC - HI-WALL UNIT
Xpower Sensation light commercial high-wall indoor unit offers optimised
comfort with an excellent seasonal energy efficiency ratio. In addition
Air4Life and the ionizer provide superior indoor air quality.
CONTROLS
3 sizes in cooling only and heat pump capacities from: 1,7 kW to 11 kW in cooling; 1,5
kW to 11,5 kW in heating.
FEATURES
Extra Power, Ionizer and Eco function
Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.
Stable indoor comfort and extremely low room temperature fluctuation.
Continuous low-speed operation and compressor sound blankets ensure
exceptionally low noise levels for superior acoustic comfort.
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.
Powerful dehumidification ensures humidity level control during all seasons.
A perfect combination of ionised and micro-filtered air for a clean and healthy
indoor environment.
OUTDOOR UNITS
monosplit 38VYX_N
22
23
42PQV_S LC - HI-WALL UNIT
INVERTER SPLIT SYSTEM
Indoor unit
42PQV050S
42PQV080S
42PQV110S
Outdoor unit HP
38VYX050N
38VYX080N
38VYX110N
9,20
Nominal cooling capacity
kW
4,80
6,50
Minimum cooling capacity
kW
1,00
2,10
2,20
Maximum cooling capacity
kW
5,25
7,00
11,00
W
1780
2490
3333
W/W
2,70
2,61
2,76
D
D
D
kW
890
1245
1667
Nominal power input
EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%
W/W (1)
4,30
4,20
4,80
Nominal heating capacity
kW
5,25
7,60
10,10
Minimum heating capacity
kW
0,90
1,70
2,20
Maximum heating capacity
kW
6,50
7,94
12,5
Nominal power input
W
1540
2750
2962
W/W
3,41
2,76
3,41
B
E
B
5,20
4,00
5,10
050
080
110
COP
Energy efficiency class (HP)
COP 50%
W/W (1)
Indoor unit
Deumidification
l/h
1,8
2,0
2,1
Nominal air flow (low/med/high)
l/s
160/200/230
95/125/147
145/179/212
Sound pressure (low/med/high) (CO)
dB(A)*
36/40/43
28/34/39
34/40/45
Sound power (low/med/high) (CO)
dB(A)
49/53/56
41/47/52
47/53/58
Sound pressure (low/med/high) (HP)
dB(A)*
34/38/41
275 x 790 x 208
275 x 790 x 208
Sound power (low/med/high) (HP)
dB(A)
47/51/54
10
10
Dimensions (H x L x D)
mm
285x1080x200
285x1080x200
446x546x356
Weight
kg
14
14
23
V-Ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
Power supply
Outdoor unit (HP)
050
080
110
Compressor Type
Twin Rotary
Twin Rotary
Twin Rotary
Maximum pipe lenght
m
30
50
50
Maximum height difference
m
30
30 (15)
30 (15)
Chargeless pipe lenght
m
20
20
20
m3/h
290/665
290/110
nd/2085
dB(A)**
43
45
51
Air Flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
dB(A)
63
65
71
dB(A)**
45
47
51
dB(A)
65
67
71
Dimensions (H x L x D)
mm
595x780x270
795x900x320
1340x900x320
Weight
kg
35
55
75
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
Sound pressure (HP)
Sound power (HP)
Flare connections
Starting current
Power supply
A
12
15
22
V-Ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
42PQV_S LC INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40PQV_S LC
42PQV_S LC - HI-WALL UNIT
DC Blended Inverter Technology: more comfort
and effective cost savings.
42PQV_S LC - HI-WALL UNIT
Xpower Sensation light commercial high-wall indoor unit offers optimised
comfort with an excellent seasonal energy efficiency ratio. In addition
Air4Life and the ionizer provide superior indoor air quality.
CONTROLS
3 sizes in cooling only and heat pump capacities from: 1,7 kW to 11 kW in cooling; 1,5
kW to 11,5 kW in heating.
FEATURES
Extra Power, Ionizer and Eco function
Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.
Stable indoor comfort and extremely low room temperature fluctuation.
Continuous low-speed operation and compressor sound blankets ensure
exceptionally low noise levels for superior acoustic comfort.
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter.
Powerful dehumidification ensures humidity level control during all seasons.
A perfect combination of ionised and micro-filtered air for a clean and healthy
indoor environment.
OUTDOOR UNITS
monosplit 38VYX_N
22
23
42VQV - CONSOLE UNIT
INVERTER SPLIT SYSTEM
Indoor unit
42VQV0050
42VQV080
42VQV110
42VQV130
Outdoor unit (HP)
38VYX050N
38VYX080N
42VYX080N
42VYX080N
11,72
Nominal cooling capacity
kW
4,85
6,5
9,10
Minimum cooling capacity
kW
1,5
2,1
2,20
3,00
Maximum cooling capacity
kW
5,25
7,2
11,00
13,00
W
1780
2430
3480
4160
W/W
2,72
2,67
2,61
2,70
D
D
D
D
890
1215
1740
2080
Nominal power input
EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%
kWh
W/W (1)
3,9
4,2
4,80
4,30
Nominal heating capacity
kW
5,19
7,32
9,60
12,36
Minimum heating capacity
kW
1,5
2,2
2,20
3,00
Maximum heating capacity
kW
6
7,94
12,50
15,00
W
1770
2600
2990
4530
W/W
2,93
2,82
3,21
2,70
D
D
C
E
4,4
4,5
4,50
4,40
50
80
110
130
Nominal power input
COP
Energy efficiency class (HP)
COP 50%
W/W (1)
Indoor unit
Dehumidification
l/h
1,7
2,7
nd
nd
Air flow (l/m/h)
l/s
150/170/205
165/195/220
265/300/330
380/405/445
Sound pressure (CO)
dB(A)*
38/41/45
41/44/49
47/50/52
47/49/51
Sound power (CO)
dB(A)
49/52/56
52/55/60
58/61/63
58/60/62
Sound pressure (HP)
dB(A)*
38/41/45
41/44/49
44/50/52
47/49/51
Sound power (HP)
dB(A)
49/52/56
52/55/60
58/61/63
58/60/62
Dimensions (HxLxD)
mm
598x1000x200
598x1000x200
625x1200x232
625x1200x232
Weight
kg
18
20
27
38
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
Power Supply
Outdoor unit (HP)
50
80
110
130
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe length
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe length
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
Dimensions (HxLxD)
mm
595x780x270
795x900x320
795x900x320
795x900x320
Weight
kg
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
35
55
75
85
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
3/8” - 5/8”
A
12
15
22
23
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
Flare Connections
Starting current
Power Supply
220/240-1-50
SIZE 30 PRELIMINARY DATA
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
42VQV INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 42VQV
42VQV - CONSOLE UNIT
Fits under a window sill. Reduced footprint and
compact overall dimensions for a wide choice
of installation solutions.
42VQV - CONSOLE UNIT
The XPower 42VQV console units provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They are slim and stylish and
designed for installation on a wall or under the ceiling.
CONTROLS
2 sizes in cooling only and heat pump capacities from: 1,5kW to 7,2kW in cooling; 1,5kW
to 7,94kW in heating.
FEATURES
Award from the Italian Association of Industrial Design (ADI).
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m. Filter can be washed and regenerated in sunlight.
Motorised louvre allows air distribution direction according to individual preferences.
MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Condensate discharge pump.
Piping cover kit.
Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.
OUTDOOR UNITS
Monosplit: 38VYX_N
24
25
42VQV - CONSOLE UNIT
INVERTER SPLIT SYSTEM
Indoor unit
42VQV0050
42VQV080
42VQV110
42VQV130
Outdoor unit (HP)
38VYX050N
38VYX080N
42VYX080N
42VYX080N
11,72
Nominal cooling capacity
kW
4,85
6,5
9,10
Minimum cooling capacity
kW
1,5
2,1
2,20
3,00
Maximum cooling capacity
kW
5,25
7,2
11,00
13,00
W
1780
2430
3480
4160
W/W
2,72
2,67
2,61
2,70
D
D
D
D
890
1215
1740
2080
Nominal power input
EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%
kWh
W/W (1)
3,9
4,2
4,80
4,30
Nominal heating capacity
kW
5,19
7,32
9,60
12,36
Minimum heating capacity
kW
1,5
2,2
2,20
3,00
Maximum heating capacity
kW
6
7,94
12,50
15,00
W
1770
2600
2990
4530
W/W
2,93
2,82
3,21
2,70
D
D
C
E
4,4
4,5
4,50
4,40
50
80
110
130
Nominal power input
COP
Energy efficiency class (HP)
COP 50%
W/W (1)
Indoor unit
Dehumidification
l/h
1,7
2,7
nd
nd
Air flow (l/m/h)
l/s
150/170/205
165/195/220
265/300/330
380/405/445
Sound pressure (CO)
dB(A)*
38/41/45
41/44/49
47/50/52
47/49/51
Sound power (CO)
dB(A)
49/52/56
52/55/60
58/61/63
58/60/62
Sound pressure (HP)
dB(A)*
38/41/45
41/44/49
44/50/52
47/49/51
Sound power (HP)
dB(A)
49/52/56
52/55/60
58/61/63
58/60/62
Dimensions (HxLxD)
mm
598x1000x200
598x1000x200
625x1200x232
625x1200x232
Weight
kg
18
20
27
38
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
Power Supply
Outdoor unit (HP)
50
80
110
130
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe length
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe length
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
Dimensions (HxLxD)
mm
595x780x270
795x900x320
795x900x320
795x900x320
Weight
kg
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
35
55
75
85
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
3/8” - 5/8”
A
12
15
22
23
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
Flare Connections
Starting current
Power Supply
220/240-1-50
SIZE 30 PRELIMINARY DATA
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
42VQV INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 42VQV
42VQV - CONSOLE UNIT
Fits under a window sill. Reduced footprint and
compact overall dimensions for a wide choice
of installation solutions.
42VQV - CONSOLE UNIT
The XPower 42VQV console units provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They are slim and stylish and
designed for installation on a wall or under the ceiling.
CONTROLS
2 sizes in cooling only and heat pump capacities from: 1,5kW to 7,2kW in cooling; 1,5kW
to 7,94kW in heating.
FEATURES
Award from the Italian Association of Industrial Design (ADI).
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m. Filter can be washed and regenerated in sunlight.
Motorised louvre allows air distribution direction according to individual preferences.
MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Condensate discharge pump.
Piping cover kit.
Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.
OUTDOOR UNITS
Monosplit: 38VYX_N
24
25
40KQV - CASSETTE UNIT
INVERTER SPLIT SYSTEM
Indoor unit
40KQV050
40KQV080
40KQV110
40KQV130
Outdoor unit (HP)
38VYX050N
38VYX080N
38VYX110N
38VYX130N
12,40
Nominal cooling capacity
kW
4,85
6,60
10,30
Minimum cooling capacity
kW
1,50
2,20
2,20
3,00
Maximum cooling capacity
kW
5,25
7,90
11,50
13,50
W
1830
2350
3610
4350
W/W
2,65
2,81
2,85
2,85
D
C
C
na
kWh
915
1175
1805
-
W/W (1)
4,00
4,50
4,00
3,50
Nominal heating capacity
kW
5,07
7,55
10,10
13,00
Minimum heating capacity
kW
1,50
2,2
2,2
3
Maximum heating capacity
kW
6,00
9
12
15
W
1550
2350
3150
4050
W/W
3,27
3,21
3,21
3,21
C
C
C
na
W/W (1)
4,10
4,50
4,50
4,40
50
80
110
130
l/h
1,7
1,8
3,7
4,5
Nominal power input
EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%
Nominal power input
COP
Energy efficiency class (HP)
COP 50%
Indoor unit
Dehumidification
Air flow (l/m/h)
l/s
190/210/250
200/250/300
320/385/455
420/465/525
Sound pressure (CO)
dB(A)*
38/42/45
32/36/39
37/42/45
42/46/48
Sound power (CO)
dB(A)
51/55/58
45/49/52
50/55/58
55/59/61
Sound pressure (HP)
dB(A)*
38/42/45
31/34/37
37/42/45
42/46/48
Sound power (HP)
dB(A)
51/55/58
44/47/50
50/55/58
55/59/61
Dimensions (HxLxD)
mm
298x575x575
298x825x825
298x825x825
298x825x825
Weight
mm
19
38
38
38
Grille Dimensions(HxLxD)
mm
30x720x720
30x960x960
30x960x960
30x960x960
Grille weight
kg
3,1
6,5
6,5
6,5
Outdoor unit (HP)
50
80
110
130
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe length
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe length
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
Dimensions (HxLxD)
mm
595x780x270
795x900x320
795x900x320
795x900x320
Weight
kg
35
55
75
85
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Flare Connections
Starting current
Power Supply
1/4 - 1/2
3/8 - 5/8
3/8 - 5/8
3/8 - 5/8
A
12
15
22
23
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
40KQV INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40KQV
40KQV
Powerful filtration system with photo-catalytic
titanium filters and high-efficiency electrostatic
filters.
40KQV - CASSETTE UNIT
The XPower 40KQV cassettes provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They received a design awarded
from the Italian Association of Industrial Design and are the ideal choice for
commercial applications.
CONTROLS
4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,5kW in cooling;
1,5kW to 15,0 kW in heating
FEATURES
Simply opening the grille gives access to all critical components.
Freedom of choice between infrared remote control and wired controls.
Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Fresh air inlet for constant air renewal.
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m and high-efficiency electrostatic filters.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.
ACCESSORIES
Air supply outlet obstruction kit
Stable indoor comfort with extremely low indoor temperature fluctuation.
OUTDOOR UNITS
Monosplit: 38VYX_N
26
27
40KQV - CASSETTE UNIT
INVERTER SPLIT SYSTEM
Indoor unit
40KQV050
40KQV080
40KQV110
40KQV130
Outdoor unit (HP)
38VYX050N
38VYX080N
38VYX110N
38VYX130N
12,40
Nominal cooling capacity
kW
4,85
6,60
10,30
Minimum cooling capacity
kW
1,50
2,20
2,20
3,00
Maximum cooling capacity
kW
5,25
7,90
11,50
13,50
W
1830
2350
3610
4350
W/W
2,65
2,81
2,85
2,85
D
C
C
na
kWh
915
1175
1805
-
W/W (1)
4,00
4,50
4,00
3,50
Nominal heating capacity
kW
5,07
7,55
10,10
13,00
Minimum heating capacity
kW
1,50
2,2
2,2
3
Maximum heating capacity
kW
6,00
9
12
15
W
1550
2350
3150
4050
W/W
3,27
3,21
3,21
3,21
C
C
C
na
W/W (1)
4,10
4,50
4,50
4,40
50
80
110
130
l/h
1,7
1,8
3,7
4,5
Nominal power input
EER
Energy efficiency class (CO)
Annual energy consumption
EER 50%
Nominal power input
COP
Energy efficiency class (HP)
COP 50%
Indoor unit
Dehumidification
Air flow (l/m/h)
l/s
190/210/250
200/250/300
320/385/455
420/465/525
Sound pressure (CO)
dB(A)*
38/42/45
32/36/39
37/42/45
42/46/48
Sound power (CO)
dB(A)
51/55/58
45/49/52
50/55/58
55/59/61
Sound pressure (HP)
dB(A)*
38/42/45
31/34/37
37/42/45
42/46/48
Sound power (HP)
dB(A)
51/55/58
44/47/50
50/55/58
55/59/61
Dimensions (HxLxD)
mm
298x575x575
298x825x825
298x825x825
298x825x825
Weight
mm
19
38
38
38
Grille Dimensions(HxLxD)
mm
30x720x720
30x960x960
30x960x960
30x960x960
Grille weight
kg
3,1
6,5
6,5
6,5
Outdoor unit (HP)
50
80
110
130
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe length
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe length
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
Dimensions (HxLxD)
mm
595x780x270
795x900x320
795x900x320
795x900x320
Weight
kg
35
55
75
85
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Flare Connections
Starting current
Power Supply
1/4 - 1/2
3/8 - 5/8
3/8 - 5/8
3/8 - 5/8
A
12
15
22
23
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
40KQV INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40KQV
40KQV
Powerful filtration system with photo-catalytic
titanium filters and high-efficiency electrostatic
filters.
40KQV - CASSETTE UNIT
The XPower 40KQV cassettes provide optimised comfort levels with an
excellent seasonal energy efficiency ratio. They received a design awarded
from the Italian Association of Industrial Design and are the ideal choice for
commercial applications.
CONTROLS
4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,5kW in cooling;
1,5kW to 15,0 kW in heating
FEATURES
Simply opening the grille gives access to all critical components.
Freedom of choice between infrared remote control and wired controls.
Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Fresh air inlet for constant air renewal.
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 5m and high-efficiency electrostatic filters.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.
ACCESSORIES
Air supply outlet obstruction kit
Stable indoor comfort with extremely low indoor temperature fluctuation.
OUTDOOR UNITS
Monosplit: 38VYX_N
26
27
40DQV - SATELLITE UNITS
INVERTER SPLIT SYSTEM
Indoor units
40DQV050
40DQV080
40DQV110
40DQV130
Outdoor units
38VYX050N
38VYX080N
38VYX110N
38VYX130N
12,40
Nominal cooling capacity
kW
5,00
6,70
10,00
Minimum cooling capacity
kW
1,50
2,10
2,20
3,00
Maximum cooling capacity
kW
5,25
7,20
11,50
13,00
W
1910
2500
3430
4500
W/W
2,62
2,68
2,92
2,76
D
D
C
ns
kWh
955
1250
1715
–
W/W (1)
4,30
4,30
4,80
4,30
Nominal heating capacity
kW
5,00
2,00
11,10
13,50
Minimum heating capacity
kW
1,50
2,00
2,20
3,00
Maximum heating capacity
kW
6,00
8,80
12,50
15,00
Nominal power input
W
1430
2600
3210
3850
COP / Energy, efficiency class
W/W
3,50
2,96
3,46
3,45
Energy efficiency class
W/W
B
D
B
na
W/W (1)
4,80
4,80
5,10
4,80
050
080
110
130
Nominal power input
EER
Energy efficiency class
Annual Energy Consuption (CO)
EER 50%
COP 50%
Indoor unit
Dehumidification
l/h
1,6
2
3,1
3,8
Air flow (low/med/high)
l/s
210/263/294
205/211/269
291/380/463
390/476/564
Nominal static pressure
Pa
50
50
80
80
Sound Pressure (low/med/high) (CO)
dB(A)
39/40/42
38/40/42
44/46/49
46/49/52
Sound Power (low/med/high) (CO)
dB(A)
52/53/55
51/53/55
57/59/62
59/62/65
Sound Pressure (low/med/high) (HP)
dB(A)
39/40/42
38/40/42
44/46/49
46/49/52
Sound Power (low/med/high) (HP)
dB(A)
52/53/55
51/53/55
57/59/62
59/62/65
Dimensions
mm
925x750x285
925x750x285
1325x750x285
1325x750x285
Weight
kg
32
35
48
48
050
080
110
130
Outdoor unit
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe lenght
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe lenght
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
mm
595x780x270
795x900x320
795x900x320
795x900x320
kg
35
55
75
85
inch
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
3/8” - 5/8”
A
12
15
22
23
V-ph-Hz
220-240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
285
40DQV INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40DQV
40DQV
Ultra-slim profile - only 285 mm for all sizes,
thanks to the Carrier-patented V-shaped coil.
40DQV - SATELLITE UNITS
The new ducted above-ceiling XPower units from Carrier represent a
breakthrough in design terms. They provide best level of comfort with an
excellent seasonal energy efficiency ratio. The slimmest profile ever and
flexible installation options make this unit the best choice for homes and
light commercial premises.
CONTROLS
4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,0kW in cooling;
1,5kW to 15,0 kW in heating.
FEATURES
Freedom of choice between infrared remote control and wired controls.
Designed for front or side air discharge.
Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.
ACCESSORIES
MyComfort infrared control kit.
Control box equipped with 1.5-m cable for flexible positioning and accessibility.
OUTDOOR UNITS
Monosplit: 38VYX_N
28
29
40DQV - SATELLITE UNITS
INVERTER SPLIT SYSTEM
Indoor units
40DQV050
40DQV080
40DQV110
40DQV130
Outdoor units
38VYX050N
38VYX080N
38VYX110N
38VYX130N
12,40
Nominal cooling capacity
kW
5,00
6,70
10,00
Minimum cooling capacity
kW
1,50
2,10
2,20
3,00
Maximum cooling capacity
kW
5,25
7,20
11,50
13,00
W
1910
2500
3430
4500
W/W
2,62
2,68
2,92
2,76
D
D
C
ns
kWh
955
1250
1715
–
W/W (1)
4,30
4,30
4,80
4,30
Nominal heating capacity
kW
5,00
2,00
11,10
13,50
Minimum heating capacity
kW
1,50
2,00
2,20
3,00
Maximum heating capacity
kW
6,00
8,80
12,50
15,00
Nominal power input
W
1430
2600
3210
3850
COP / Energy, efficiency class
W/W
3,50
2,96
3,46
3,45
Energy efficiency class
W/W
B
D
B
na
W/W (1)
4,80
4,80
5,10
4,80
050
080
110
130
Nominal power input
EER
Energy efficiency class
Annual Energy Consuption (CO)
EER 50%
COP 50%
Indoor unit
Dehumidification
l/h
1,6
2
3,1
3,8
Air flow (low/med/high)
l/s
210/263/294
205/211/269
291/380/463
390/476/564
Nominal static pressure
Pa
50
50
80
80
Sound Pressure (low/med/high) (CO)
dB(A)
39/40/42
38/40/42
44/46/49
46/49/52
Sound Power (low/med/high) (CO)
dB(A)
52/53/55
51/53/55
57/59/62
59/62/65
Sound Pressure (low/med/high) (HP)
dB(A)
39/40/42
38/40/42
44/46/49
46/49/52
Sound Power (low/med/high) (HP)
dB(A)
52/53/55
51/53/55
57/59/62
59/62/65
Dimensions
mm
925x750x285
925x750x285
1325x750x285
1325x750x285
Weight
kg
32
35
48
48
050
080
110
130
Outdoor unit
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe lenght
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe lenght
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
mm
595x780x270
795x900x320
795x900x320
795x900x320
kg
35
55
75
85
inch
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
3/8” - 5/8”
A
12
15
22
23
V-ph-Hz
220-240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
(1) According to pr CEN/TS 14825, E.E.R. 50% and C.O.P. 50% refer to the energy efficiency when the system delivers 50% of cooling or heating capacity
285
40DQV INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 40DQV
40DQV
Ultra-slim profile - only 285 mm for all sizes,
thanks to the Carrier-patented V-shaped coil.
40DQV - SATELLITE UNITS
The new ducted above-ceiling XPower units from Carrier represent a
breakthrough in design terms. They provide best level of comfort with an
excellent seasonal energy efficiency ratio. The slimmest profile ever and
flexible installation options make this unit the best choice for homes and
light commercial premises.
CONTROLS
4 sizes in cooling only and heat pump capacities from: 1,5kW to 13,0kW in cooling;
1,5kW to 15,0 kW in heating.
FEATURES
Freedom of choice between infrared remote control and wired controls.
Designed for front or side air discharge.
Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.
ACCESSORIES
MyComfort infrared control kit.
Control box equipped with 1.5-m cable for flexible positioning and accessibility.
OUTDOOR UNITS
Monosplit: 38VYX_N
28
29
38VYX_N - CONDENSING UNITS
Outdoor unit (HP)
38VYX50N
38VYX080N
38VYX110N
38VYX130N
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe length
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe length
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
mm
595x780x270
795x900x320
795x900x320
795x900x320
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply
kg
35
55
75
85
inch
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
3/8” - 5/8”
A
12
15
22
23
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
38VYX_N INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 38VYX_N
INVERTER SPLIT SYSTEM
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
Twin rotary compressor to reduce vibration and
noise and to provide superior efficiency performance.
OPERATING LIMITS
Cooling mode
Heating mode
38VYX_N
maximum
conditions
outdoor temperature 43°C.
indoor temperature 32°C dry bulb / 23°C wet bulb.
minimum
conditions
outdoor temperature -5°C (080, 110, 130); -15°C (050).
indoor temperature 21°C dry bulb / 15°C wet bulb.
maximum
conditions
outdoor temperature 24°C dry bulb / 18°C wet bulb.
indoor temperature 27°C dry bulb.
minimum
conditions
outdoor temperature -15°C dry bulb.
38VYX_N - CONDENSING UNITS
CONTROLS
4 sizes in cooling only and heat pump.
FEATURES
Freedom of choice between infrared remote control and wired controls.
Systems can operate at -5°C in cooling mode and -15°C in heating mode.
Outdoor and outdoor fan speeds are electronically fine tuned to deliver the needed air
flow reach the best performance.
INDOOR UNITS
No current peaks: Start-up current absorption is always lower than operating current
value.
Advanced self-diagnosis tool for an automatic complete system check-up and for maintenance routine monitoring.
Designed for challenging installations. Up to 50 m in distance and 30 m in elevation;
chargeless up to 20 m.
42PQV_S lc
The pulse modulation valve (PVM) regulates the refrigerant flow in the circuit.
42VQV
40KQV
40DQV
30
31
38VYX_N - CONDENSING UNITS
Outdoor unit (HP)
38VYX50N
38VYX080N
38VYX110N
38VYX130N
Compressor Type
Twin rotary
Twin rotary
Twin rotary
Twin rotary
Maximum pipe length
m
30
50
50
50
Maximum height difference
m
30
30
30
30
Chargeless pipe length
m
20
20
20
20
m3/h
290/665
290/1110
nd/1890
nd/2085
dB(A)**
43
45
51
51
dB(A)
63
65
71
71
dB(A)**
45
47
51
51
dB(A)
65
67
71
71
mm
595x780x270
795x900x320
795x900x320
795x900x320
Air flow (Min/Max)
Sound pressure (CO)
Sound power (CO)
Sound pressure (HP)
Sound power (HP)
Dimensions (HxLxD)
Weight
Flare Connections
Starting current
Power Supply
kg
35
55
75
85
inch
1/4” - 1/2”
3/8” - 5/8”
3/8” - 5/8”
3/8” - 5/8”
A
12
15
22
23
V-ph-Hz
220/240-1-50
220/240-1-50
220/240-1-50
220/240-1-50
38VYX_N INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 38VYX_N
INVERTER SPLIT SYSTEM
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
Twin rotary compressor to reduce vibration and
noise and to provide superior efficiency performance.
OPERATING LIMITS
Cooling mode
Heating mode
38VYX_N
maximum
conditions
outdoor temperature 43°C.
indoor temperature 32°C dry bulb / 23°C wet bulb.
minimum
conditions
outdoor temperature -5°C (080, 110, 130); -15°C (050).
indoor temperature 21°C dry bulb / 15°C wet bulb.
maximum
conditions
outdoor temperature 24°C dry bulb / 18°C wet bulb.
indoor temperature 27°C dry bulb.
minimum
conditions
outdoor temperature -15°C dry bulb.
38VYX_N - CONDENSING UNITS
CONTROLS
4 sizes in cooling only and heat pump.
FEATURES
Freedom of choice between infrared remote control and wired controls.
Systems can operate at -5°C in cooling mode and -15°C in heating mode.
Outdoor and outdoor fan speeds are electronically fine tuned to deliver the needed air
flow reach the best performance.
INDOOR UNITS
No current peaks: Start-up current absorption is always lower than operating current
value.
Advanced self-diagnosis tool for an automatic complete system check-up and for maintenance routine monitoring.
Designed for challenging installations. Up to 50 m in distance and 30 m in elevation;
chargeless up to 20 m.
42PQV_S lc
The pulse modulation valve (PVM) regulates the refrigerant flow in the circuit.
42VQV
40KQV
40DQV
30
31
38VGM_N/VYM_N - MULTI-SPLIT CONDENSING UNIT
INVERTER SPLIT SYSTEM
38VYM-14N
38VYM-18N
38VYM-28N
N. of compressors
Model HP
1
1
1
1
Compressor type
Twin Rotary
Twin Rotary
Twin Rotary
Twin Rotary
38VYM-32N
Refrigerant charge
g
900
1150
2400
2400
Maximum pipe lenght per unit
m
20
20
25
25
Mimimum pipe lenght per unit
m (4)
2(5)
2(5)
2
2
Maximum height difference
m
10
10
15
15
Total pipe lenght
m
30
30
50
70
Total chargless pipe lenght
m
30
30
50
70
1
1
2
2
dB (A)
43
43
48
48
Min. no. of connected indoor units
Sound pressure (CO)
Sound power (CO)
dB (A)
63
63
68
68
dB (A) (2)
44
44
48
48
dB (A)
64
64
68
68
Air flow (min./nominal/max)
l/s
344/539/656
344/539/656
383/656/689
383/656/689
Dimensions (H x L x D)
mm
590x800x300
590x800x300
800x800x300
800x800x300
Weight
kg
46
50
65
65
n° x (in) (3)
2x(1/4”) - 2x(3/8”)
2x(1/4”) - 2x(3/8”)
3x(1/4”) - 3x(3/8”)
4x(1/4”) - 4x(3/8”)
A (5)
11,5
11,5
14,2
14,2
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
Sound pressure (HP)
Sound power (HP)
Flare Connections
Maximum running current
Power supply
38VGM_N/VYM_N INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 38VGM_N/VYM_N
38VGM_N/VYM_N Inverter Multi Condensing Unit
DC Blended Inverter Technology – the sophisticated electronics system maximises performance and inverter savings.
PRELIMINARY DATA
38VGM_N/VYM_N
38VGM-14N
38VGM-18N
38VGM-18N
N. of compressors
Model CO
1
1
1
1
Compressor type
Twin Rotary
Twin Rotary
Twin Rotary
Twin Rotary
900
1150
2400
2400
25
Refrigerant charge
g
38VGM-32N
Maximum pipe lenght per unit
m
20
20
25
Mimimum pipe lenght per unit
m (4)
2 (5)
2 (5)
2
2
Maximum height difference
m
10
10
15
15
Total pipe lenght
m
30
30
50
70
Total chargless pipe lenght
m
30
30
50
70
1
1
2
2
dB(A) (2)
43
43
48
48
dB (A)
63
63
68
68
Air flow (min./nominal/max)
l/s
344/539/656
344/539/656
383/656/689
383/656/689
Dimensions (H x L x D)
mm
590x800x300
590x800x300
800x800x300
800x800x300
Weight
kg
46
50
65
65
n° x
2x(1/4”) - 2x(3/8”)
2x(1/4”) - 2x(3/8”)
3x(1/4”) - 3x(3/8”)
4x(1/4”) - 4x(3/8”)
Min. no. of connected indoor units
Sound pressure (CO)
Sound power (CO)
Flare Connections
Maximum running current
Power supply
2) Sound pressure level in emispheric field at 4 m
3) Connecting pipes for PQM015 and SQM015 must be 1/4" - 1/2"
Flare adapter to be mounted on outdoor unit will be supplied together with indoor unit
4) 5 meters with one unit connected.
5) Variable speed compressor can reduce this value during operation.
11,5
11,5
14,2
14,2
230-1-50
230-1-50
230-1-50
230-1-50
PRELIMINARY DATA
CONTROLS
38VGM_N/VYM_N is the Carrier inverter multi-split outdoor unit. Carrier's
inverter multisplit range multiplies the XPower advantages, so several
rooms can be air conditioned at low cost.
4 sizes in cooling only and heat pump.
FEATURES
Suitable for long-distance pipes: a single condensing unit can be connected up
to four hi-walls mounted in different areas of the house.
Self-diagnosis system: counting on 40 different check codes, the diagnostic
process is extremely precise and effective.
Electronic modulation valves regulate the refrigerant flow and optimise the cooling temperature in the refrigeration circuit.
Modular control system
ACCESSORIES/OPTIONS
Wall brackets
INDOOR UNITS
The provided refrigerant charge fits any combination; systems don't require any
additional charge, making installations easier and faster.
Corrosion-resistant base and cabinet, made UV-resistant polymer materials.
42PQM_S
40SQM
32
33
38VGM_N/VYM_N - MULTI-SPLIT CONDENSING UNIT
INVERTER SPLIT SYSTEM
38VYM-14N
38VYM-18N
38VYM-28N
N. of compressors
Model HP
1
1
1
1
Compressor type
Twin Rotary
Twin Rotary
Twin Rotary
Twin Rotary
38VYM-32N
Refrigerant charge
g
900
1150
2400
2400
Maximum pipe lenght per unit
m
20
20
25
25
Mimimum pipe lenght per unit
m (4)
2(5)
2(5)
2
2
Maximum height difference
m
10
10
15
15
Total pipe lenght
m
30
30
50
70
Total chargless pipe lenght
m
30
30
50
70
1
1
2
2
dB (A)
43
43
48
48
Min. no. of connected indoor units
Sound pressure (CO)
Sound power (CO)
dB (A)
63
63
68
68
dB (A) (2)
44
44
48
48
dB (A)
64
64
68
68
Air flow (min./nominal/max)
l/s
344/539/656
344/539/656
383/656/689
383/656/689
Dimensions (H x L x D)
mm
590x800x300
590x800x300
800x800x300
800x800x300
Weight
kg
46
50
65
65
n° x (in) (3)
2x(1/4”) - 2x(3/8”)
2x(1/4”) - 2x(3/8”)
3x(1/4”) - 3x(3/8”)
4x(1/4”) - 4x(3/8”)
A (5)
11,5
11,5
14,2
14,2
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
Sound pressure (HP)
Sound power (HP)
Flare Connections
Maximum running current
Power supply
38VGM_N/VYM_N INVERTER SPLIT SYSTEM
INVERTER SPLIT SYSTEM 38VGM_N/VYM_N
38VGM_N/VYM_N Inverter Multi Condensing Unit
DC Blended Inverter Technology – the sophisticated electronics system maximises performance and inverter savings.
PRELIMINARY DATA
38VGM_N/VYM_N
38VGM-14N
38VGM-18N
38VGM-18N
N. of compressors
Model CO
1
1
1
1
Compressor type
Twin Rotary
Twin Rotary
Twin Rotary
Twin Rotary
900
1150
2400
2400
25
Refrigerant charge
g
38VGM-32N
Maximum pipe lenght per unit
m
20
20
25
Mimimum pipe lenght per unit
m (4)
2 (5)
2 (5)
2
2
Maximum height difference
m
10
10
15
15
Total pipe lenght
m
30
30
50
70
Total chargless pipe lenght
m
30
30
50
70
1
1
2
2
dB(A) (2)
43
43
48
48
dB (A)
63
63
68
68
Air flow (min./nominal/max)
l/s
344/539/656
344/539/656
383/656/689
383/656/689
Dimensions (H x L x D)
mm
590x800x300
590x800x300
800x800x300
800x800x300
Weight
kg
46
50
65
65
n° x
2x(1/4”) - 2x(3/8”)
2x(1/4”) - 2x(3/8”)
3x(1/4”) - 3x(3/8”)
4x(1/4”) - 4x(3/8”)
Min. no. of connected indoor units
Sound pressure (CO)
Sound power (CO)
Flare Connections
Maximum running current
Power supply
2) Sound pressure level in emispheric field at 4 m
3) Connecting pipes for PQM015 and SQM015 must be 1/4" - 1/2"
Flare adapter to be mounted on outdoor unit will be supplied together with indoor unit
4) 5 meters with one unit connected.
5) Variable speed compressor can reduce this value during operation.
11,5
11,5
14,2
14,2
230-1-50
230-1-50
230-1-50
230-1-50
PRELIMINARY DATA
CONTROLS
38VGM_N/VYM_N is the Carrier inverter multi-split outdoor unit. Carrier's
inverter multisplit range multiplies the XPower advantages, so several
rooms can be air conditioned at low cost.
4 sizes in cooling only and heat pump.
FEATURES
Suitable for long-distance pipes: a single condensing unit can be connected up
to four hi-walls mounted in different areas of the house.
Self-diagnosis system: counting on 40 different check codes, the diagnostic
process is extremely precise and effective.
Electronic modulation valves regulate the refrigerant flow and optimise the cooling temperature in the refrigeration circuit.
Modular control system
ACCESSORIES/OPTIONS
Wall brackets
INDOOR UNITS
The provided refrigerant charge fits any combination; systems don't require any
additional charge, making installations easier and faster.
Corrosion-resistant base and cabinet, made UV-resistant polymer materials.
42PQM_S
40SQM
32
33
42PHQ_S - HI-WALL UNIT
FIXED SPEED SPLIT SYSTEM
Indoor unit
42PHQ009S
42PHQ012S
42PHQ014S
42PHQ018S
42PHQ024S
Outdoor unit
38BC-009G
38BC-012G
38BC-014G
38GL-018G
38GL-024G
Cooling capacity (CO)
kW
2,82
3,43
3,90
5,22
6,03
Power input (CO)
W
920
1200
1540
2130
2500
2,41
Energy efficiency class
3,07
2,86
2,53
2,45
EER
W/W
460
C
E
E
E
Annual energy consumption (CO)
kWh
B
600
770
1065
1250
38YY-024G
Outdoor unit
38BH-009G
38BH-0124
38BH-0144
38YY-018G
Cooling capacity (CO)
kW
2,75
3,37
3,89
5,02
6,14
Power input (CO)
W
840
1120
1480
2010
2510
W/W
3,27
3,01
2,63
2,50
2,45
A
B
D
E
E
560
740
1005
1255
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
420
Heating capacity
kW
3,07
3,65
4,40
5,59
7,53
Power input (HP)
W
880
1190
1490
1960
2680
W/W
3,49
3,07
2,95
2,85
2,81
B
D
D
D
D
009
012
014
018
024
COP
Energy efficiency class (HP)
42PHQ_S FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42PHQ_S
42PHQ_S - HI-Wall unit
Ioniser Function
Indoor unit
Dehumidification
l/h
0,90
1,20
1,46
1,54
2,08
Air flow (l/m/h)
l/s
116/132/154
125/143/165
150/168/187
204/223/242
250/275/300
Sound pressure (l/m/h)
dB(A)*
30/31/35
32/36/39
39/41/43
39/41/43
43/46/49
Sound power (l/m/h)
dB(A)
43/44/48
45/49/52
52/54/56
52/54/57
56/59/62
Dimensions (HxLxD)
mm
260x790x196
260x790x196
260x790x196
295x1080x200
295x1080x200
Weight
Power Supply
kg
8,6
8,6
8,6
14
14
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
009
012
014
018
024
Outdoor unit
Compressor Type
Rotary
Rotary
Rotary
Rotary
Rotary
Maximum pipe length
m
10
15
15
30
40
Maximum height difference
m
5
5
8
15
15
Chargeless
m
10
10
10
8
8
dB(A)**
38/38
38/38
40/40
45/46
45/48
dB(A)
58/58
58/58
60/60
65/66
65/68
Dimensions (HxLxD)
mm
550x780x270
550x780x270
590x750x280
590x800x300
803x800x300
Weight (CO/HP)
kg
30/33
33/36
35/37
45
51/60
Flare Connections
A
3/8” - 1/4”
1/2” - 1/4”
1/2” - 1/4”
1/2” - 1/4”
1/2” - 1/4”
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Sound pressure (CO/HP)
Sound power (CO/HP)
Power Supply
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
42PHQ_S - HI-WALL UNITS
Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.
CONTROLS
10 sizes in cooling only and heat pump capacities from: 2,82 kW to 6,03 kW in cooling;
2,75 kW to 6,14 kW in heating.
FEATURES
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.
The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.
Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.
My comfort
Remote Control
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Programmable timer for easy on and off selection with great energy savings.
Creat-ion is felt, but not heard. The indoor unit is extremely quiet to ensure total
relaxation.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YY_M
34
35
42PHQ_S - HI-WALL UNIT
FIXED SPEED SPLIT SYSTEM
Indoor unit
42PHQ009S
42PHQ012S
42PHQ014S
42PHQ018S
42PHQ024S
Outdoor unit
38BC-009G
38BC-012G
38BC-014G
38GL-018G
38GL-024G
Cooling capacity (CO)
kW
2,82
3,43
3,90
5,22
6,03
Power input (CO)
W
920
1200
1540
2130
2500
2,41
Energy efficiency class
3,07
2,86
2,53
2,45
EER
W/W
460
C
E
E
E
Annual energy consumption (CO)
kWh
B
600
770
1065
1250
38YY-024G
Outdoor unit
38BH-009G
38BH-0124
38BH-0144
38YY-018G
Cooling capacity (CO)
kW
2,75
3,37
3,89
5,02
6,14
Power input (CO)
W
840
1120
1480
2010
2510
W/W
3,27
3,01
2,63
2,50
2,45
A
B
D
E
E
560
740
1005
1255
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
420
Heating capacity
kW
3,07
3,65
4,40
5,59
7,53
Power input (HP)
W
880
1190
1490
1960
2680
W/W
3,49
3,07
2,95
2,85
2,81
B
D
D
D
D
009
012
014
018
024
COP
Energy efficiency class (HP)
42PHQ_S FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42PHQ_S
42PHQ_S - HI-Wall unit
Ioniser Function
Indoor unit
Dehumidification
l/h
0,90
1,20
1,46
1,54
2,08
Air flow (l/m/h)
l/s
116/132/154
125/143/165
150/168/187
204/223/242
250/275/300
Sound pressure (l/m/h)
dB(A)*
30/31/35
32/36/39
39/41/43
39/41/43
43/46/49
Sound power (l/m/h)
dB(A)
43/44/48
45/49/52
52/54/56
52/54/57
56/59/62
Dimensions (HxLxD)
mm
260x790x196
260x790x196
260x790x196
295x1080x200
295x1080x200
Weight
Power Supply
kg
8,6
8,6
8,6
14
14
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
009
012
014
018
024
Outdoor unit
Compressor Type
Rotary
Rotary
Rotary
Rotary
Rotary
Maximum pipe length
m
10
15
15
30
40
Maximum height difference
m
5
5
8
15
15
Chargeless
m
10
10
10
8
8
dB(A)**
38/38
38/38
40/40
45/46
45/48
dB(A)
58/58
58/58
60/60
65/66
65/68
Dimensions (HxLxD)
mm
550x780x270
550x780x270
590x750x280
590x800x300
803x800x300
Weight (CO/HP)
kg
30/33
33/36
35/37
45
51/60
Flare Connections
A
3/8” - 1/4”
1/2” - 1/4”
1/2” - 1/4”
1/2” - 1/4”
1/2” - 1/4”
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Sound pressure (CO/HP)
Sound power (CO/HP)
Power Supply
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
42PHQ_S - HI-WALL UNITS
Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.
CONTROLS
10 sizes in cooling only and heat pump capacities from: 2,82 kW to 6,03 kW in cooling;
2,75 kW to 6,14 kW in heating.
FEATURES
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.
The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.
Customised air distribution - six different air flow positions and exclusive Twin
Swing air distribution function.
My comfort
Remote Control
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Programmable timer for easy on and off selection with great energy savings.
Creat-ion is felt, but not heard. The indoor unit is extremely quiet to ensure total
relaxation.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YY_M
34
35
42PHQ_A - HI-WALL UNIT
FIXED SPEED SPLIT SYSTEM
42PHQ_A - HI-Wall unit
Indoor unit
42PHQ009A
42PHQ012A
38YP-009
38YP-012
Cooling capacity (CO)
kW
2,75
3,50
Power input (CO)
W
856
1090
W/W
3,21
3,21
EER
Energy efficiency class (CO)
A
A
545
Annual energy consumption
kWh
428
Heating capacity
kW
3,07
3,80
Power input (HP)
W
850
1052
W/W
3,61
3,61
A
A
009
012
COP
Energy efficiency class (HP)
Indoor unit
Dehumidification
l/h
0,9
1,2
Air flow (l/m/h)
l/s
93/118/153
118/132/203
Sound pressure (l/m/h)
dB(A)*
27/30/39
41/43/45
Sound power (l/m/h)
dB(A)
40/43/52
52/54/56
Dimensions (HxLxD)
mm
260x790x196
260x790x196
Weight
kg
8,6
8,6
V-ph-Hz
230-1-50
230-1-50
Power Supply
Outdoor unit (HP)
009
012
Compressor Type
Rotary
Rotary
Maximum pipe length
m
10
15
Maximum height difference
m
5
5
Chargeless
m
10
10
dB(A)**
40
41
dB(A)
60
61
Dimensions (HxLxD)
mm
550x780x270
550x780x270
Weight
kg
32
40
Flare Connections
A
3/8” - 1/4”
1/2” - 1/4”
V-ph-Hz
230-1-50
230-1-50
Sound pressure
Sound power
Power Supply
Class A efficiency in cooling and heating
The ultimate evolution of comfort with maximised savings.
42PHQ_A FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42PHQ_A
Outdoor unit (HP)
42PHQ_A - HI-WALL UNITS
Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.
CONTROLS
2 sizes in cooling only and heat pump capacities from: 2,75 kW to 3,50 kW in cooling;
3,07 kW to 3,80 kW in heating.
Ionizer function
FEATURES
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter
Programmable timer for easy on and off selection with great energy savings;
includes a sleep function to automatically manage the right temperature during
the night.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.
OUTDOOR UNITS
Monosplit: 38YP
36
37
42PHQ_A - HI-WALL UNIT
FIXED SPEED SPLIT SYSTEM
42PHQ_A - HI-Wall unit
Indoor unit
42PHQ009A
42PHQ012A
38YP-009
38YP-012
Cooling capacity (CO)
kW
2,75
3,50
Power input (CO)
W
856
1090
W/W
3,21
3,21
EER
Energy efficiency class (CO)
A
A
545
Annual energy consumption
kWh
428
Heating capacity
kW
3,07
3,80
Power input (HP)
W
850
1052
W/W
3,61
3,61
A
A
009
012
COP
Energy efficiency class (HP)
Indoor unit
Dehumidification
l/h
0,9
1,2
Air flow (l/m/h)
l/s
93/118/153
118/132/203
Sound pressure (l/m/h)
dB(A)*
27/30/39
41/43/45
Sound power (l/m/h)
dB(A)
40/43/52
52/54/56
Dimensions (HxLxD)
mm
260x790x196
260x790x196
Weight
kg
8,6
8,6
V-ph-Hz
230-1-50
230-1-50
Power Supply
Outdoor unit (HP)
009
012
Compressor Type
Rotary
Rotary
Maximum pipe length
m
10
15
Maximum height difference
m
5
5
Chargeless
m
10
10
dB(A)**
40
41
dB(A)
60
61
Dimensions (HxLxD)
mm
550x780x270
550x780x270
Weight
kg
32
40
Flare Connections
A
3/8” - 1/4”
1/2” - 1/4”
V-ph-Hz
230-1-50
230-1-50
Sound pressure
Sound power
Power Supply
Class A efficiency in cooling and heating
The ultimate evolution of comfort with maximised savings.
42PHQ_A FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42PHQ_A
Outdoor unit (HP)
42PHQ_A - HI-WALL UNITS
Creat-ion recreates the atmosphere of natural environments in your home,
providing a sense of well-being and vitality for all the family.
CONTROLS
2 sizes in cooling only and heat pump capacities from: 2,75 kW to 3,50 kW in cooling;
3,07 kW to 3,80 kW in heating.
Ionizer function
FEATURES
Stylish and compact with pleasant white flat panel aesthetic for easy integration
into any room interiors.
Exclusive 4-stage filtration system: anti-bacterial pre-filter, electrostatic filter,
regenerable photo-catalytic filter and anti - bacterial fan and drain pan treatment.
* Sound pressure level in a free field according to JIS9612 Standard
** Sound pressure level in emispheric field at 4 m
Performances evaluated with 5m interconnecting tubes and according to EN14511
The ioniser adds millions of negative ions to the air, creating an immediate sensation of well-being.
ACCESSORIES
Filter kit: photo-catalytic and passive electrostatic filter
Programmable timer for easy on and off selection with great energy savings;
includes a sleep function to automatically manage the right temperature during
the night.
Exclusive, ergonomic and personalised remote control - the unique MyComfort
function memorises preferred user settings and ensures easy recall.
OUTDOOR UNITS
Monosplit: 38YP
36
37
42VMC_N - CONSOLE UNITS
FIXED SPEED SPLIT SYSTEM
Indoor unit
42VMC009N
42VMC012N
42VMC014N
42VMC018N
42VMC024N
42VMC028N
42VMC036N
42VMC048N
Outdoor unit (CO)
38BC-009G
38BC-012G
38BC-014G
38GL-018G
38GL-024G
38GL-028G9
38GL-036G9
38GL-048G9
Cooling capacity (CO)
kW
2,69
3,27
4,47
5,34
6,01
7,6
8,3
10,1
Power input (CO)
W
920
1200
1640
2190
2510
2860
3280
3500
W/W
2,92
2,73
2,73
2,44
2,39
2,66
2,53
2,89
C
D
D
E
F
D
E
C
460
600
820
1095
1255
1430
1640
1750
38YY-048G9
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Outdoor unit (HP)
38BH-009G
38BH-012G
38BH-014G
38YY-018G
38YY-024G
38YY-028G9
38YY-036G9
Cooling capacity (CO)
kW
2,62
3,22
4,35
5,26
6,4
7,3
8,1
10,1
Power input (CO)
W
830
1130
1630
2090
2720
3070
3430
3510
W/W
3,16
2,85
2,67
2,52
2,35
2,38
2,36
2,88
B
C
D
E
F
F
F
C
565
815
1045
1360
1535
1715
1755
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
415
Heating capacity
kW
2,94
3,52
4,75
5,67
6,8
8
8,9
10,9
Power input (HP)
W
960
1260
1570
2030
2570
2880
3230
3800
W/W
3,06
2,79
3,03
2,79
2,65
2,78
2,76
2,87
D
E
D
E
E
E
E
D
09
12
14
18
24
28
36
48
1
1
-
2,5
2,5
-
-
-
COP
Energy efficiency class (HP)
Indoor unit
Electric heater
kW
Dehumidification
l/h
1,2
1,5
1,7
2
2,2
2,8
3,1
3,6
Air flow (l/m/h)
l/s
78/88/100
85/96/114
130/150/170
136/162/199
164/202/249
240/275/302
240/275/302
313/337/364
Sound pressure (l/m/h)
dB(A)*
33/36/39
36/38/42
38/39/41
38/41/46
41/44/50
44/48/50
44/48/50
48/50/53
Sound power (l/m/h)
dB(A)
44/47/50
47/49/53
49/50/52
49/52/57
52/55/61
55/59/61
55/59/61
59/61/64
Dimensions (HxLxD)
mm
540x850x200
540x850x200
Weight
Power Supply
kg
15
16
18
18
20
35
35
36
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
09
12
14
18
24
28
36
48
8 sizes in cooling only and heat pump capacities from: 2,69kW to 10,10kW in cooling;
2,94kW to 10,9kW in heating.
rotary
rotary
rotary
rotary
rotary
scroll
scroll
scroll
15
15
15
30
40
40
50
50
Compressor Type
Air flow (CO/HP)
Sound pressure (CO/HP)
Sound power (CO/HP)
Dimensions (HxLxD) (CO)
m
598x1000x200 598x1000x200 598x1000x200 610x1200x225 610x1200x225 610x1200x225
m
5
5
8
15
15
25
30
30
m
10
10
10
8
8
8
8
8
m3/h
1540
1540
1540
1900/2400
1900/2600
2400
2400/3100
4900/4200
38 / 38
38 / 38
40 / 40
45 / 46
45 / 49
48 / 48
49 / 52
53 / 54
Award from the Italian Association of Industrial Design (ADI).
dB(A)
58 / 58
58 / 58
60 / 60
65 / 66
65 / 69
68 / 68
69 / 72
73 / 74
mm
590x750x280
590x750x280
590x750x280
590x800x300
590x800x300
803x800x300
803x800x300
1264x800x300
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 µm. Filter can be washed and regenerated in sunlight.
kg
30
33
35
45
51
65
65
92
Dimensions (HxLxD) (HP)
mm
590x750x280
590x750x280
590x750x280
590x800x300
803x800x300
803x800x300
803x800x300
1264x800x300
Flare Connections
Starting current
Power Supply
*
**
FEATURES
dB(A)**
Weight (CO)
Weight (HP)
42VMC_N - CONSOLE UNITS
Carrier console units are slim and stylish, making many conventional air
conditioning units look old-fashioned in comparison. A versatile solution,
designed for installation on a wall or under the ceiling.
Outdoor unit
Maximum pipe length (CO/HP)
Maximum height difference
(CO/HP)
Chargeless pipe length (CO/HP)
Stylish design for modern interiors.
kg
33
36
37
47
60
67
68
94
inch
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
5/8 - 1/4
3/4 - 3/8
3/4 - 3/8
A
17
24
28
50
56
37
39
54
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
400-3-50
400-3-50
400-3-50
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
Motorised louvre allows air distribution direction according to individual preferences.
MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.
42VMC_N FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42VMC_N
42 VMC-N Console & Underceiling
CONTROLS
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Condensate discharge pump
Hot water coil kit
Piping cover kit
Electric heater
Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
38
39
42VMC_N - CONSOLE UNITS
FIXED SPEED SPLIT SYSTEM
Indoor unit
42VMC009N
42VMC012N
42VMC014N
42VMC018N
42VMC024N
42VMC028N
42VMC036N
42VMC048N
Outdoor unit (CO)
38BC-009G
38BC-012G
38BC-014G
38GL-018G
38GL-024G
38GL-028G9
38GL-036G9
38GL-048G9
Cooling capacity (CO)
kW
2,69
3,27
4,47
5,34
6,01
7,6
8,3
10,1
Power input (CO)
W
920
1200
1640
2190
2510
2860
3280
3500
W/W
2,92
2,73
2,73
2,44
2,39
2,66
2,53
2,89
C
D
D
E
F
D
E
C
460
600
820
1095
1255
1430
1640
1750
38YY-048G9
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Outdoor unit (HP)
38BH-009G
38BH-012G
38BH-014G
38YY-018G
38YY-024G
38YY-028G9
38YY-036G9
Cooling capacity (CO)
kW
2,62
3,22
4,35
5,26
6,4
7,3
8,1
10,1
Power input (CO)
W
830
1130
1630
2090
2720
3070
3430
3510
W/W
3,16
2,85
2,67
2,52
2,35
2,38
2,36
2,88
B
C
D
E
F
F
F
C
565
815
1045
1360
1535
1715
1755
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
415
Heating capacity
kW
2,94
3,52
4,75
5,67
6,8
8
8,9
10,9
Power input (HP)
W
960
1260
1570
2030
2570
2880
3230
3800
W/W
3,06
2,79
3,03
2,79
2,65
2,78
2,76
2,87
D
E
D
E
E
E
E
D
09
12
14
18
24
28
36
48
1
1
-
2,5
2,5
-
-
-
COP
Energy efficiency class (HP)
Indoor unit
Electric heater
kW
Dehumidification
l/h
1,2
1,5
1,7
2
2,2
2,8
3,1
3,6
Air flow (l/m/h)
l/s
78/88/100
85/96/114
130/150/170
136/162/199
164/202/249
240/275/302
240/275/302
313/337/364
Sound pressure (l/m/h)
dB(A)*
33/36/39
36/38/42
38/39/41
38/41/46
41/44/50
44/48/50
44/48/50
48/50/53
Sound power (l/m/h)
dB(A)
44/47/50
47/49/53
49/50/52
49/52/57
52/55/61
55/59/61
55/59/61
59/61/64
Dimensions (HxLxD)
mm
540x850x200
540x850x200
Weight
Power Supply
kg
15
16
18
18
20
35
35
36
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
09
12
14
18
24
28
36
48
8 sizes in cooling only and heat pump capacities from: 2,69kW to 10,10kW in cooling;
2,94kW to 10,9kW in heating.
rotary
rotary
rotary
rotary
rotary
scroll
scroll
scroll
15
15
15
30
40
40
50
50
Compressor Type
Air flow (CO/HP)
Sound pressure (CO/HP)
Sound power (CO/HP)
Dimensions (HxLxD) (CO)
m
598x1000x200 598x1000x200 598x1000x200 610x1200x225 610x1200x225 610x1200x225
m
5
5
8
15
15
25
30
30
m
10
10
10
8
8
8
8
8
m3/h
1540
1540
1540
1900/2400
1900/2600
2400
2400/3100
4900/4200
38 / 38
38 / 38
40 / 40
45 / 46
45 / 49
48 / 48
49 / 52
53 / 54
Award from the Italian Association of Industrial Design (ADI).
dB(A)
58 / 58
58 / 58
60 / 60
65 / 66
65 / 69
68 / 68
69 / 72
73 / 74
mm
590x750x280
590x750x280
590x750x280
590x800x300
590x800x300
803x800x300
803x800x300
1264x800x300
Equipped with photo-catalytic titanium filters that remove odours and impurities
up to 0.01 µm. Filter can be washed and regenerated in sunlight.
kg
30
33
35
45
51
65
65
92
Dimensions (HxLxD) (HP)
mm
590x750x280
590x750x280
590x750x280
590x800x300
803x800x300
803x800x300
803x800x300
1264x800x300
Flare Connections
Starting current
Power Supply
*
**
FEATURES
dB(A)**
Weight (CO)
Weight (HP)
42VMC_N - CONSOLE UNITS
Carrier console units are slim and stylish, making many conventional air
conditioning units look old-fashioned in comparison. A versatile solution,
designed for installation on a wall or under the ceiling.
Outdoor unit
Maximum pipe length (CO/HP)
Maximum height difference
(CO/HP)
Chargeless pipe length (CO/HP)
Stylish design for modern interiors.
kg
33
36
37
47
60
67
68
94
inch
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
5/8 - 1/4
3/4 - 3/8
3/4 - 3/8
A
17
24
28
50
56
37
39
54
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
400-3-50
400-3-50
400-3-50
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
Motorised louvre allows air distribution direction according to individual preferences.
MyComfort remote control function memorises the preferred user settings.
State-of-the-art fans and advanced slim-line coil make the console unit exceptionally quiet.
42VMC_N FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42VMC_N
42 VMC-N Console & Underceiling
CONTROLS
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Condensate discharge pump
Hot water coil kit
Piping cover kit
Electric heater
Fits under a window sill. Reduced footprint and compact overall dimensions for
a wide choice of installation solutions.
All key components are easily accessible through the grille without removing
the front panel.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
38
39
40KMC_N - CASSETTE UNITS
FIXED SPEED SPLIT SYSTEM
40KMC-N Cassette
Indoor unit
40KMC012-7N
40KMC018-7N
40KMC024-7N
40KMC028-7N
40KMC036-7N
40KMC048-7N
40KMC060-7N
38BC-012G
38GL-018G
38GL-024G
38GL-028G9
38GL-036G9
38GL-048G9
38GL-060G9
Cooling capacity (CO)
kW
3,58
5,59
6,1
8,28
9
10,9
13,6
Power input (CO)
W
1240
2180
2460
2880
3320
3540
4900
W/W
2,89
2,56
2,48
2,88
2,71
3,08
2,78
C
E
E
C
D
B
na
620
1090
1230
1440
1660
1770
-
12
18
24
28
36
48
60
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Outdoor unit (HP)
Cooling capacity (CO)
kW
3,52
4,92
6,23
7,86
8,74
10,92
12,4
Power input (CO)
W
1160
2000
2790
3100
3470
3540
5220
W/W
3,03
2,46
2,23
2,54
2,52
3,08
2,38
B
E
F
E
E
B
na
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
580
1000
1395
1550
1735
1770
-
Heating capacity
kW
3,78
5,38
7,02
8,03
8,94
10,87
13,24
W
1280
2160
2780
2640
2960
3490
4620
W/W
2,95
2,49
2,53
3,04
3,02
3,11
2,87
D
F
F
D
D
D
na
Power input (HP)
COP
Energy efficiency class (HP)
Indoor unit
12
18
24
28
36
48
60
1,5
1,5+1,0
1,5+1,0
2,0+1,0
2,0+1,0
2,0+1,0
2,0+1,0
Electric heater
kW
Dehumidification
l/h
0,8
1,9
2,5
3,0
3,5
4,6
5,2
Air flow (l/m/h)
l/s
152/167/183
156/175/194
189/213/250
200/250/300
270/305/350
320/390/460
400/470/515
Sound pressure (l/m/h)
dB(A)*
27/31/34
30/33/36
35/38/42
29/32/36
33/36/39
37/42/45
43/46/49
Sound power (l/m/h)
dB(A)
40/44/47
43/46/49
48/51/55
42/45/49
46/49/52
50/55/58
56/59/62
Dimensions (HxLxD)
mm
298/575/575
298/575/575
298/575/575
298/825/825
298/825/825
298/825/825
298/825/825
Weight
kg
17,5
19
19
36,0
38,0
38,0
41
Grille Dimensions(HxLxD)
mm
30/720/720
30/720/720
30/720/720
30/960/960
30/960/960
30/960/960
30/960/960
Grille weight
kg
2,5
2,5
2,5
5,0
5,0
5,0
5
Power Supply
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Outdoor unit
Compressor Type
12
18
24
28
36
48
60
rotary
rotary
rotary
rotary
scroll
scroll
scroll
Maximum pipe length (CO/HP)
m
15
30
40
40
50
50
50
Maximum height difference (CO/HP)
m
5
15
15
25
30
30
30
Chargeless pipe length (CO/HP)
m
10
8
8
8
8
8
8
m3/h
1540
1900/2400
1900/2600
2400
2400/3100
4900/4200
4900/4200
dB(A)**
38 / 38
45 / 46
45 / 49
48 / 48
49 / 52
53 / 54
52 / 53
dB(A)
58 / 58
65 / 66
65 / 69
68 / 68
69 / 72
73 / 74
72 / 73
Dimensions (HxLxD) (CO)
mm
590x750x280
590x800x300
590x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
Weight (CO)
kg
33
45
51
65
65
92
94
Dimensions (HxLxD) (HP)
mm
590x750x280
590x800x300
803x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
Air flow (CO/HP)
Sound pressure (CO/HP)
Sound power (CO/HP)
Weight (HP)
Flare Connections
Starting current
Power Supply
*
**
kg
36
47
60
67
68
94
96
inch
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
5/8 - 1/4
3/4 - 3/8
3/4 - 3/8
3/4 - 3/8
A
28
50
56
37
39
54
64
V-ph-Hz
230-1-50
230-1-50
230-1-50
400-3-50
400-3-50
400-3-50
400-3-50
The patented wing-shaped centrifugal fan, new
heat exchanger and improved air management
system ensure near-perfect acoustic performance.
40KMC_N FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 40KMC_N
Outdoor unit (CO)
40KMC_N - CASSETTE UNITS
If you need a system with the right combination of performance, style and
flexibility, the Carrier cassette is the natural choice.
CONTROLS
7 sizes in cooling only and heat pump capacities from: 3,58kW to 13,6kW in cooling;
3,78kW to 13,24kW in heating.
FEATURES
Standard dimensions compatible with all suspended ceiling systems in common
use in shops and offices.
Award from the Italian Association of Industrial Design (ADI).
Simply opening the grille gives access to all critical components.
Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Air4Life kit: photo-catalytic titanium and electrostatic filters
Air supply outlet obstruction kit
Electric heater
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
40
41
40KMC_N - CASSETTE UNITS
FIXED SPEED SPLIT SYSTEM
40KMC-N Cassette
Indoor unit
40KMC012-7N
40KMC018-7N
40KMC024-7N
40KMC028-7N
40KMC036-7N
40KMC048-7N
40KMC060-7N
38BC-012G
38GL-018G
38GL-024G
38GL-028G9
38GL-036G9
38GL-048G9
38GL-060G9
Cooling capacity (CO)
kW
3,58
5,59
6,1
8,28
9
10,9
13,6
Power input (CO)
W
1240
2180
2460
2880
3320
3540
4900
W/W
2,89
2,56
2,48
2,88
2,71
3,08
2,78
C
E
E
C
D
B
na
620
1090
1230
1440
1660
1770
-
12
18
24
28
36
48
60
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Outdoor unit (HP)
Cooling capacity (CO)
kW
3,52
4,92
6,23
7,86
8,74
10,92
12,4
Power input (CO)
W
1160
2000
2790
3100
3470
3540
5220
W/W
3,03
2,46
2,23
2,54
2,52
3,08
2,38
B
E
F
E
E
B
na
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
580
1000
1395
1550
1735
1770
-
Heating capacity
kW
3,78
5,38
7,02
8,03
8,94
10,87
13,24
W
1280
2160
2780
2640
2960
3490
4620
W/W
2,95
2,49
2,53
3,04
3,02
3,11
2,87
D
F
F
D
D
D
na
Power input (HP)
COP
Energy efficiency class (HP)
Indoor unit
12
18
24
28
36
48
60
1,5
1,5+1,0
1,5+1,0
2,0+1,0
2,0+1,0
2,0+1,0
2,0+1,0
Electric heater
kW
Dehumidification
l/h
0,8
1,9
2,5
3,0
3,5
4,6
5,2
Air flow (l/m/h)
l/s
152/167/183
156/175/194
189/213/250
200/250/300
270/305/350
320/390/460
400/470/515
Sound pressure (l/m/h)
dB(A)*
27/31/34
30/33/36
35/38/42
29/32/36
33/36/39
37/42/45
43/46/49
Sound power (l/m/h)
dB(A)
40/44/47
43/46/49
48/51/55
42/45/49
46/49/52
50/55/58
56/59/62
Dimensions (HxLxD)
mm
298/575/575
298/575/575
298/575/575
298/825/825
298/825/825
298/825/825
298/825/825
Weight
kg
17,5
19
19
36,0
38,0
38,0
41
Grille Dimensions(HxLxD)
mm
30/720/720
30/720/720
30/720/720
30/960/960
30/960/960
30/960/960
30/960/960
Grille weight
kg
2,5
2,5
2,5
5,0
5,0
5,0
5
Power Supply
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Outdoor unit
Compressor Type
12
18
24
28
36
48
60
rotary
rotary
rotary
rotary
scroll
scroll
scroll
Maximum pipe length (CO/HP)
m
15
30
40
40
50
50
50
Maximum height difference (CO/HP)
m
5
15
15
25
30
30
30
Chargeless pipe length (CO/HP)
m
10
8
8
8
8
8
8
m3/h
1540
1900/2400
1900/2600
2400
2400/3100
4900/4200
4900/4200
dB(A)**
38 / 38
45 / 46
45 / 49
48 / 48
49 / 52
53 / 54
52 / 53
dB(A)
58 / 58
65 / 66
65 / 69
68 / 68
69 / 72
73 / 74
72 / 73
Dimensions (HxLxD) (CO)
mm
590x750x280
590x800x300
590x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
Weight (CO)
kg
33
45
51
65
65
92
94
Dimensions (HxLxD) (HP)
mm
590x750x280
590x800x300
803x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
Air flow (CO/HP)
Sound pressure (CO/HP)
Sound power (CO/HP)
Weight (HP)
Flare Connections
Starting current
Power Supply
*
**
kg
36
47
60
67
68
94
96
inch
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
5/8 - 1/4
3/4 - 3/8
3/4 - 3/8
3/4 - 3/8
A
28
50
56
37
39
54
64
V-ph-Hz
230-1-50
230-1-50
230-1-50
400-3-50
400-3-50
400-3-50
400-3-50
The patented wing-shaped centrifugal fan, new
heat exchanger and improved air management
system ensure near-perfect acoustic performance.
40KMC_N FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 40KMC_N
Outdoor unit (CO)
40KMC_N - CASSETTE UNITS
If you need a system with the right combination of performance, style and
flexibility, the Carrier cassette is the natural choice.
CONTROLS
7 sizes in cooling only and heat pump capacities from: 3,58kW to 13,6kW in cooling;
3,78kW to 13,24kW in heating.
FEATURES
Standard dimensions compatible with all suspended ceiling systems in common
use in shops and offices.
Award from the Italian Association of Industrial Design (ADI).
Simply opening the grille gives access to all critical components.
Fresh air intake and additional outlet grille allow air conditioning of an adjoining
room.
Two, three and four-way motorised louvres allow air flow direction according to
individual preferences.
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Air4Life kit: photo-catalytic titanium and electrostatic filters
Air supply outlet obstruction kit
Electric heater
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
40
41
40SMC_N - SATELLITE UNITS
Indoor unit
40SMC009N
40SMC012N
40SMC018N
Outdoor unit (CO)
38BC-009G
38BC-012G
38GL-018G
Cooling capacity (CO)
kW
2,71
3,41
5,09
Power input (CO)
W
1030
1250
2300
W/W
2,63
2,73
2,21
D
D
F
kWh
515
625
1150
09
12
18
kW
2,64
3,35
5,11
W
950
1170
2180
W/W
2,78
2,86
2,34
D
C
F
475
585
1090
EER
Energy efficiency class (CO)
Annual energy consumption
Outdoor unit (HP)
Cooling capacity (CO)
Power input (CO)
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Heating capacity
kW
3,2
3,76
5,44
Power input (HP)
W
980
1250
2170
W/W
3,27
3,01
2,51
C
D
F
COP
Energy efficiency class (HP)
Indoor unit
09
12
18
Dehumidification
l/h
0,5
0,8
1,9
Air flow (l/m/h)
l/s
92/103/133
103/118/139
126/149/182
Static Pressure
Pa
33
40
45
Sound pressure (l/m/h)
dB(A)*
42/43/44
42/44/45
43/45/47
Sound power (l/m/h)
dB(A)
55/56/57
56/57/58
56/58/60
Dimensions (HxLxD)
mm
220x725x555
220x725x555
220x725x555
Weight
Power Supply
kg
23
23
23
V-ph-Hz
230-1-50
230-1-50
230-1-50
Outdoor unit
Compressor Type
09
12
18
rotary
rotary
rotary
Maximum pipe length (CO/HP)
m
15
15
30
Maximum height difference (CO/HP)
m
5
5
15
Chargeless pipe length (CO/HP)
m
10
10
8
Air flow (CO/HP)
m3/h
1540
1540
1900/2400
dB(A)**
38 / 38
38 / 38
45 / 46
dB(A)
58 / 58
58 / 58
65 / 66
Dimensions (HxLxD) (CO)
mm
590x750x280
590x750x280
590x800x300
Weight (CO)
kg
30
33
45
Dimensions (HxLxD) (HP)
mm
590x750x280
590x750x280
590x800x300
Sound pressure (CO/HP)
Sound power (CO/HP)
Weight (HP)
Flare Connections
Starting current
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
kg
33
36
47
inch
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
A
24
28
50
V-ph-Hz
230-1-50
230-1-50
230-1-50
Installation flexibility with a wide range of
accessories.
40SMC_N - SATELLITE UNITS
With its compact size and flexibility the Carrier 40SMC ducted system is the
ideal choice for both new and refurbished buildings.
40SMC_N FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 40SMC_N
FIXED SPEED SPLIT SYSTEM
CONTROLS
8 sizes in cooling only and heat pump capacities from: 2,71kW to 13,6kW in cooling;
3,2kW to 14,00kW in heating.
FEATURES
The preferred solution for consultants and installers - quick and easy to install,
compatible with existing electrical and plumbing systems.
Ducted system - the ideal choice for both new and refurbished houses.
Filters, coils, motors and valves are easily accessible by removing only a few
screws.
Powerful three-speed direct-drive fan delivers air at up to 80 Pa external static
pressure.
Unique slim-line profile - the low unit height permits installation even in low ceilings.
Compact and 30% lighter than other ducted units on the market.
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Electric heater.
Hot water coil and anti-freeze thermostat.
Mixing box for fresh air.
Suction plenum.
Discharge plenum.
Octopus - two, three or four outlets.
High-efficiency gravimetric filter.
3-way, 4-connection valve for hot water coil.
MyComfort infrared control kit.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
42
43
40SMC_N - SATELLITE UNITS
Indoor unit
40SMC009N
40SMC012N
40SMC018N
Outdoor unit (CO)
38BC-009G
38BC-012G
38GL-018G
Cooling capacity (CO)
kW
2,71
3,41
5,09
Power input (CO)
W
1030
1250
2300
W/W
2,63
2,73
2,21
D
D
F
kWh
515
625
1150
09
12
18
kW
2,64
3,35
5,11
W
950
1170
2180
W/W
2,78
2,86
2,34
D
C
F
475
585
1090
EER
Energy efficiency class (CO)
Annual energy consumption
Outdoor unit (HP)
Cooling capacity (CO)
Power input (CO)
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Heating capacity
kW
3,2
3,76
5,44
Power input (HP)
W
980
1250
2170
W/W
3,27
3,01
2,51
C
D
F
COP
Energy efficiency class (HP)
Indoor unit
09
12
18
Dehumidification
l/h
0,5
0,8
1,9
Air flow (l/m/h)
l/s
92/103/133
103/118/139
126/149/182
Static Pressure
Pa
33
40
45
Sound pressure (l/m/h)
dB(A)*
42/43/44
42/44/45
43/45/47
Sound power (l/m/h)
dB(A)
55/56/57
56/57/58
56/58/60
Dimensions (HxLxD)
mm
220x725x555
220x725x555
220x725x555
Weight
Power Supply
kg
23
23
23
V-ph-Hz
230-1-50
230-1-50
230-1-50
Outdoor unit
Compressor Type
09
12
18
rotary
rotary
rotary
Maximum pipe length (CO/HP)
m
15
15
30
Maximum height difference (CO/HP)
m
5
5
15
Chargeless pipe length (CO/HP)
m
10
10
8
Air flow (CO/HP)
m3/h
1540
1540
1900/2400
dB(A)**
38 / 38
38 / 38
45 / 46
dB(A)
58 / 58
58 / 58
65 / 66
Dimensions (HxLxD) (CO)
mm
590x750x280
590x750x280
590x800x300
Weight (CO)
kg
30
33
45
Dimensions (HxLxD) (HP)
mm
590x750x280
590x750x280
590x800x300
Sound pressure (CO/HP)
Sound power (CO/HP)
Weight (HP)
Flare Connections
Starting current
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
kg
33
36
47
inch
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
A
24
28
50
V-ph-Hz
230-1-50
230-1-50
230-1-50
Installation flexibility with a wide range of
accessories.
40SMC_N - SATELLITE UNITS
With its compact size and flexibility the Carrier 40SMC ducted system is the
ideal choice for both new and refurbished buildings.
40SMC_N FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 40SMC_N
FIXED SPEED SPLIT SYSTEM
CONTROLS
8 sizes in cooling only and heat pump capacities from: 2,71kW to 13,6kW in cooling;
3,2kW to 14,00kW in heating.
FEATURES
The preferred solution for consultants and installers - quick and easy to install,
compatible with existing electrical and plumbing systems.
Ducted system - the ideal choice for both new and refurbished houses.
Filters, coils, motors and valves are easily accessible by removing only a few
screws.
Powerful three-speed direct-drive fan delivers air at up to 80 Pa external static
pressure.
Unique slim-line profile - the low unit height permits installation even in low ceilings.
Compact and 30% lighter than other ducted units on the market.
Freedom of choice between infrared remote
control and wired controls.
ACCESSORIES
Electric heater.
Hot water coil and anti-freeze thermostat.
Mixing box for fresh air.
Suction plenum.
Discharge plenum.
Octopus - two, three or four outlets.
High-efficiency gravimetric filter.
3-way, 4-connection valve for hot water coil.
MyComfort infrared control kit.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
42
43
40DMC - SATELLITE UNITS
FIXED SPEED SPLIT SYSTEM
Indoor unit
40DMC018
40DMC024
40DMC028
40DMC036
40DMC036
40DMC052
40DMC060
Outdoor unit (CO)
38GL-018G
38GL-024G
38GL-028G9
38GL-036G9
38GL-048G9
38GL-052G9
38GL-060G9
Cooling capacity (CO)
kW
5,40
6,48
8,12
8,48
9,78
11,60
13,49
Power input (CO)
W
2151
2763
3022
3201
3085
4319
4797
W/W
2,51
2,34
2,69
2,65
3,17
2,69
2,81
E
F
D
D
B
D
na
1075
1381
1511
1600
1542
2160
-
38YY-018G
38YY-024G
38YY-028G9
38YY-036G9
38YY048G9
38YY0-052G9
38YY-060G9
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Outdoor unit (HP)
Cooling capacity (CO)
kW
5,42
6,63
8,12
8,63
10,19
12,03
13,77
Power input (CO)
W
2038
2670
3040
3339
3453
4282
5041
W/W
2,66
2,48
2,67
2,59
2,95
2,81
2,73
D
E
D
E
C
na
na
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
1019
1335
1520
1669
1726
-
-
Heating capacity
kW
5,64
7,02
8,22
9,44
11,02
13,28
14,50
Power input (HP)
W
1828
2444
2278
2551
3358
4166
4110
W/W
3,09
2,87
3,61
3,70
3,28
3,19
3,53
D
D
A
A
C
na
na
COP
Energy efficiency class (HP)
Indoor unit
18
24
28
36
48
52
60
l/h
1,6
2,0
2,3
2,0
3,1
3,8
4,0
Nominal air flow (l/m/h)
l/s
210/263/294
205/211/269
244/318/383
291/380/463
291/380/463
390/476/564
569/616/667
Nominal static pressure
Pa
50
50
50
80
80
80
80
Sound pressure level (l/m/h)
dB(A)*
39/40/42
38/40/42
40/43/46
44/46/49
44/46/49
46/49/54
47/51/54
Sound power level (l/m/h)
dB(A)
52/53/55
51/53/55
53/56/59
57/59/64
57/59/64
59/62/67
60/64/67
mm
925x750x285
925x750x285
925x750x285
1325x750x285
1325x750x285
1325x750x285
1325x750x285
Dehumidification
Dimensions (H x L x D)
Weight
Power Supply
kg
32
35
35
48
48
48
53
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Outdoor unit (CO/HP)
Compressor Type
18
24
28
36
48
52
60
rotary
rotary
scroll
scroll
scroll
scroll
scroll
Maximum pipe length
m
30
40
40
50
50
50
50
Maximum height difference
m
15
15
25
30
30
30
30
Chargeless length
m
8
8
8
8
8
8
8
Air flow
l/s
667
528
667
667
1361
1361
1361
dB(A)**
45/46
45/49
48/48
49/52
53/54
53/54
52/53
Sound power level (CO/HP)
dB(A)
65/66
65/69
68/68
69/72
73/74
73/74
72/73
Dimensions (H x L x D) (CO)
mm
590x800x300
590x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
1264x800x300
Sound pressure level (CO/HP)
Weight (CO)
kg
45
51
65
65
92
94
94
Dimensions (H x L x D) (HP)
mm
590x800x300
803x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
1264x800x300
Weight (HP)
kg
47
60
67
68
94
96
96
inch
1/2 - 1/4
1/2 - 1/4
5/8 - 1/4
3/4 - 3/8
3/4 - 3/8
3/4 - 3/8
3/4 - 3/8
A
50
56
37
39
54
64
64
V-ph-Hz
230-1-50
230-1-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
Flare Connections
Starting current
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
285
Ultra-slim profile - only 285 mm for all sizes,
thanks to the Carrier-patented V-shaped coil.
40DMC - SATELLITE UNITS
40DMC FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 40DMC
40DMC Satellite
CONTROLS
The new ducted above-ceiling units from Carrier represent a breakthrough
in design terms. The slimmest profile ever and flexible installation options
make these units the best choice for homes and small commercial premises.
7 sizes in cooling only and heat pump capacities from: 5,49kW to 13,4kW in cooling;
5,31kW to 14,55kW in heating.
FEATURES
Designed for front or side air discharge.
Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.
Freedom of choice between infrared remote control and wired controls.
ACCESSORIES
Hot water coil.
Electric heater.
MyComfort infrared control kit.
Control box equipped with 1.5-m cable for flexible positioning and accessibility.
Both electric heater and hot water coil are retrofit outside the unit for easy
mounting on installed units.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
44
45
40DMC - SATELLITE UNITS
FIXED SPEED SPLIT SYSTEM
Indoor unit
40DMC018
40DMC024
40DMC028
40DMC036
40DMC036
40DMC052
40DMC060
Outdoor unit (CO)
38GL-018G
38GL-024G
38GL-028G9
38GL-036G9
38GL-048G9
38GL-052G9
38GL-060G9
Cooling capacity (CO)
kW
5,40
6,48
8,12
8,48
9,78
11,60
13,49
Power input (CO)
W
2151
2763
3022
3201
3085
4319
4797
W/W
2,51
2,34
2,69
2,65
3,17
2,69
2,81
E
F
D
D
B
D
na
1075
1381
1511
1600
1542
2160
-
38YY-018G
38YY-024G
38YY-028G9
38YY-036G9
38YY048G9
38YY0-052G9
38YY-060G9
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
Outdoor unit (HP)
Cooling capacity (CO)
kW
5,42
6,63
8,12
8,63
10,19
12,03
13,77
Power input (CO)
W
2038
2670
3040
3339
3453
4282
5041
W/W
2,66
2,48
2,67
2,59
2,95
2,81
2,73
D
E
D
E
C
na
na
EER
Energy efficiency class (CO)
Annual energy consumption
kWh
1019
1335
1520
1669
1726
-
-
Heating capacity
kW
5,64
7,02
8,22
9,44
11,02
13,28
14,50
Power input (HP)
W
1828
2444
2278
2551
3358
4166
4110
W/W
3,09
2,87
3,61
3,70
3,28
3,19
3,53
D
D
A
A
C
na
na
COP
Energy efficiency class (HP)
Indoor unit
18
24
28
36
48
52
60
l/h
1,6
2,0
2,3
2,0
3,1
3,8
4,0
Nominal air flow (l/m/h)
l/s
210/263/294
205/211/269
244/318/383
291/380/463
291/380/463
390/476/564
569/616/667
Nominal static pressure
Pa
50
50
50
80
80
80
80
Sound pressure level (l/m/h)
dB(A)*
39/40/42
38/40/42
40/43/46
44/46/49
44/46/49
46/49/54
47/51/54
Sound power level (l/m/h)
dB(A)
52/53/55
51/53/55
53/56/59
57/59/64
57/59/64
59/62/67
60/64/67
mm
925x750x285
925x750x285
925x750x285
1325x750x285
1325x750x285
1325x750x285
1325x750x285
Dehumidification
Dimensions (H x L x D)
Weight
Power Supply
kg
32
35
35
48
48
48
53
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Outdoor unit (CO/HP)
Compressor Type
18
24
28
36
48
52
60
rotary
rotary
scroll
scroll
scroll
scroll
scroll
Maximum pipe length
m
30
40
40
50
50
50
50
Maximum height difference
m
15
15
25
30
30
30
30
Chargeless length
m
8
8
8
8
8
8
8
Air flow
l/s
667
528
667
667
1361
1361
1361
dB(A)**
45/46
45/49
48/48
49/52
53/54
53/54
52/53
Sound power level (CO/HP)
dB(A)
65/66
65/69
68/68
69/72
73/74
73/74
72/73
Dimensions (H x L x D) (CO)
mm
590x800x300
590x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
1264x800x300
Sound pressure level (CO/HP)
Weight (CO)
kg
45
51
65
65
92
94
94
Dimensions (H x L x D) (HP)
mm
590x800x300
803x800x300
803x800x300
803x800x300
1264x800x300
1264x800x300
1264x800x300
Weight (HP)
kg
47
60
67
68
94
96
96
inch
1/2 - 1/4
1/2 - 1/4
5/8 - 1/4
3/4 - 3/8
3/4 - 3/8
3/4 - 3/8
3/4 - 3/8
A
50
56
37
39
54
64
64
V-ph-Hz
230-1-50
230-1-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
Flare Connections
Starting current
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
285
Ultra-slim profile - only 285 mm for all sizes,
thanks to the Carrier-patented V-shaped coil.
40DMC - SATELLITE UNITS
40DMC FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 40DMC
40DMC Satellite
CONTROLS
The new ducted above-ceiling units from Carrier represent a breakthrough
in design terms. The slimmest profile ever and flexible installation options
make these units the best choice for homes and small commercial premises.
7 sizes in cooling only and heat pump capacities from: 5,49kW to 13,4kW in cooling;
5,31kW to 14,55kW in heating.
FEATURES
Designed for front or side air discharge.
Unique design with lateral air discharge allows the unit to be installed in a corridor.
Modular filter and panel sizes allow flexible unit mounting with rear or bottom
air return.
Equipped with pre-punched 150-mm diameter fresh air intakes on both sides,
and with pre-punched Octopus discharge panel.
Freedom of choice between infrared remote control and wired controls.
ACCESSORIES
Hot water coil.
Electric heater.
MyComfort infrared control kit.
Control box equipped with 1.5-m cable for flexible positioning and accessibility.
Both electric heater and hot water coil are retrofit outside the unit for easy
mounting on installed units.
OUTDOOR UNITS
Monosplit: 38BC/BH and 38GL/YY
Multisplit: 38GL_M/YL_M
44
45
FB4X - VERTICAL DUCTED
FIXED SPEED SPLIT SYSTEM
Indoor Units
FX4CSX024
FX4CSX036
FX4CSX048
FX4CSX060
Outdoor units
38EYX024-7
38EYX036-9
38EYX048-9
38EYX060-9
Cooling capacity
kW
6,8
10,0
13,7
16,7
Nominal power input (CO)
kW
2,12
3,14
4,36
5,87
Annual Energy Consumption
kW/h
1060
1570
na
na
EER
W/W
3,22
3,18
3,13
2,85
Energy efficiency class (CO)
kW
A
B
na
na
Heating capacity
kW
6,64
10,39
14,48
17,07
Nominal power input (HP)
kW
1,83
2,98
3,82
5,04
W/W
3,63
3,49
3,79
3,39
kW
A
B
na
na
COP
Energy efficiency class HP
INDOOR UNITS (FURNACE TYPE)
24
36
48
60
l/h
3,4
4,6
7,0
8,2
Nominal air flow
l/s
475
600
750
825
Maximum static pressure
Pa
125
125
125
125
dB(A)
72
77
77
80
dB(A)***
56
61
61
64
Dimensions (HxWxD)
mm
1212x448x560
1357x537x560
1261x537x560
1357x537x560
Weight
kg
55
67
72
80
Dehumidification
Sound power
Sound pressure
HEAT PUMP CONDENSING UNITS
24
36
48
60
Compressor type
scroll
scroll
scroll
scroll
Refrigerant type
R-410A
R-410A
R-410A
R-410A
50
50
50
50
Maximum pipe lenght
Maximum elevation
Chargeless piping lenght
Additional refrigerant charge
Sound power
m
m*
45
45
45
45
m
4,5
4,5
4,5
4,5
g/m
56
56
56
56
dB(A)
72
72
72
74
Sound pressure
dB(A)**
52
52
52
54
Nominal air flow
l/s
708
1274
1416
1180
Dimensions (HxWxD)
mm
761x572x572
761x762x762
1015x762x762
862x762x762
Weight
kg
65,8
83,9
99,3
111,6
Sweat connections (liquid/gas)
in
3/8” - 5/8”
3/8” - 3/4”
3/8” - 7/8”
3/8” - 7/8”
Maximum running current
A
16,2
8,7
12,0
14,0
Installation fuse rating
A
25
15
20
20
Nominal power supply
V-ph-Hz
230-1-50
400-3-50
400-3-50
400-3-50
(*) : If the CDU is positioned below the IDU, the maximum elevation is 15meters
(**) : sound pressure level measured in hemispheric field at 4m distance from the unit
(***) : sound pressure level measured in anechoic room at 1,28m from discharge outlet on vertical wall
TECH3000
Exceptional installation flexibility - the indoor
unit can be installed in three air flow positions:
upwards, downwards or horizontal.
FB4X - VERTICAL DUCTED
Encased indoor fan coils, complete with direct-expansion indoor coil, suitable for use in cooling only and heat pump systems.
FB4X FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM FB4X
FB4X
CONTROLS
4 size in cooling only and heat pump.
FEATURES
Room thermostat
All materials used are designed and protected to resist the toughest climates.
Refrigerant circuit service valves with easily accessible pressure test ports for
start-up and maintenance.
Heat pump cycle with four-position valve (38EYX); electronic control system for
optimised defrosting.
High and low-pressure safety switches fitted as standard.
ACCESSORIES
Downflow Convertion Kit
Downflow / Horizontal Kit
Filter Kit
To assure long life and reliability outdoor unit compressors are hermetically
sealed against contamination and pollutants.
OUTDOOR UNIT
38EYX
46
47
FB4X - VERTICAL DUCTED
FIXED SPEED SPLIT SYSTEM
Indoor Units
FX4CSX024
FX4CSX036
FX4CSX048
FX4CSX060
Outdoor units
38EYX024-7
38EYX036-9
38EYX048-9
38EYX060-9
Cooling capacity
kW
6,8
10,0
13,7
16,7
Nominal power input (CO)
kW
2,12
3,14
4,36
5,87
Annual Energy Consumption
kW/h
1060
1570
na
na
EER
W/W
3,22
3,18
3,13
2,85
Energy efficiency class (CO)
kW
A
B
na
na
Heating capacity
kW
6,64
10,39
14,48
17,07
Nominal power input (HP)
kW
1,83
2,98
3,82
5,04
W/W
3,63
3,49
3,79
3,39
kW
A
B
na
na
COP
Energy efficiency class HP
INDOOR UNITS (FURNACE TYPE)
24
36
48
60
l/h
3,4
4,6
7,0
8,2
Nominal air flow
l/s
475
600
750
825
Maximum static pressure
Pa
125
125
125
125
dB(A)
72
77
77
80
dB(A)***
56
61
61
64
Dimensions (HxWxD)
mm
1212x448x560
1357x537x560
1261x537x560
1357x537x560
Weight
kg
55
67
72
80
Dehumidification
Sound power
Sound pressure
HEAT PUMP CONDENSING UNITS
24
36
48
60
Compressor type
scroll
scroll
scroll
scroll
Refrigerant type
R-410A
R-410A
R-410A
R-410A
50
50
50
50
Maximum pipe lenght
Maximum elevation
Chargeless piping lenght
Additional refrigerant charge
Sound power
m
m*
45
45
45
45
m
4,5
4,5
4,5
4,5
g/m
56
56
56
56
dB(A)
72
72
72
74
Sound pressure
dB(A)**
52
52
52
54
Nominal air flow
l/s
708
1274
1416
1180
Dimensions (HxWxD)
mm
761x572x572
761x762x762
1015x762x762
862x762x762
Weight
kg
65,8
83,9
99,3
111,6
Sweat connections (liquid/gas)
in
3/8” - 5/8”
3/8” - 3/4”
3/8” - 7/8”
3/8” - 7/8”
Maximum running current
A
16,2
8,7
12,0
14,0
Installation fuse rating
A
25
15
20
20
Nominal power supply
V-ph-Hz
230-1-50
400-3-50
400-3-50
400-3-50
(*) : If the CDU is positioned below the IDU, the maximum elevation is 15meters
(**) : sound pressure level measured in hemispheric field at 4m distance from the unit
(***) : sound pressure level measured in anechoic room at 1,28m from discharge outlet on vertical wall
TECH3000
Exceptional installation flexibility - the indoor
unit can be installed in three air flow positions:
upwards, downwards or horizontal.
FB4X - VERTICAL DUCTED
Encased indoor fan coils, complete with direct-expansion indoor coil, suitable for use in cooling only and heat pump systems.
FB4X FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM FB4X
FB4X
CONTROLS
4 size in cooling only and heat pump.
FEATURES
Room thermostat
All materials used are designed and protected to resist the toughest climates.
Refrigerant circuit service valves with easily accessible pressure test ports for
start-up and maintenance.
Heat pump cycle with four-position valve (38EYX); electronic control system for
optimised defrosting.
High and low-pressure safety switches fitted as standard.
ACCESSORIES
Downflow Convertion Kit
Downflow / Horizontal Kit
Filter Kit
To assure long life and reliability outdoor unit compressors are hermetically
sealed against contamination and pollutants.
OUTDOOR UNIT
38EYX
46
47
38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS
FIXED SPEED SPLIT SYSTEM
Flare connections [A]
inch
38GL2M12G
Rotary
Shared
–
15
5
15
331
43
63
590x660x250
39
2
3/8 - 1/4
1/2 - 1/4
Flare connections [B]
inch
-
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
3/8 - 1/4
3/8 - 1/4
A
V-ph-Hz
30
230-1-50
30 + 30
230-1-50
30 + 30
230-1-50
50 + 50
230-1-50
60 + 60
230-1-50
30 + 30
230-1-50
30 + 50
230-1-50
38YY2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
167
45
65
590x800x300
55
2
3/8 - 1/4
3/8 - 1/4
25 + 25
230-1-50
38YY2M21G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
210
48
68
803x800x300
61
2
1/2 - 1/4
1/2 - 1/4
25 + 30
230-1-50
Starting current
Power Supply
Outdoor unit (HP)
Compressor Type
Compressor [A]
Compressor [B]
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units
Flare connections [A]
Flare connections [B]
Starting current
Power Supply
*
[A]
[B]
m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg
m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg
inch
inch
A
V-ph-Hz
38GL2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15
533
45
65
590x800x300
55
2
3/8 - 1/4
38GL2M24G 38GL2M36G 38GL2M48G 38GL3M21G
Rotary
Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
shared
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
15 + 15
5
10
15
5
8+8
8+8
8+8
8 + 15
15
15
15
15/686
553 + 553
553 + 553
528
48
49
50
46
68
69
70
66
590x800x300 1264x800x300 1264x800x300 590x800x300
64
99
102
58
2
2
2
3
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
38GL3M30G
Rotary
shared
dedicated
15+30
5
8 + 15
15/553
50
70
803x800x300
75
3
3/8 - 1/4
1/2 - 1/4
38GL4M24G
Rotary
shared
shared
30 + 30
5
15 + 15
15/15
769
50
70
803x800x300
69
4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
230-1-50
38YY2M24G 38YY2M36G 38YY2M48G
Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
5
15
15
8+8
8+8
8+8
15/15
20/20
20/20
210
150
179
48
49
50
68
69
70
803x800x300 1264x800x300 1264x800x300
64
99
102
2
2
2
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
50 + 50
60 + 60
230-1-50
230-1-50
230-1-50
Sound pressure level in emispheric field at 4 m.
Performances evaluated with 5m interconnecting tubes.
DEDICATED COMPRESSORS
Ultra-reliable compressor. Ideal for both residential and small business applications.
38GL_M/YY_M - AIR-COOLED CONDENSING UNITS
CONTROLS
8 models cooling only from 2kW to 13kW and 5 models in heat pump from 5kW to 14kW
FEATURES
SHARED COMPRESSORS
38GL_M/YY_M FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M
38GL_M/YY_M Multi-split Condensing Unit
Outdoor unit (CO
Compressor Type
Compressor
Compressor
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units
Design and components optimised for operation with R410A refrigerant.
Rotary or scroll compressor, synonymous with high reliability and energy efficiency.
Modular control system
ACCESSORIES/OPTIONS
Wall bracket
Low ambient kit
Exceptionally low noise fan.
New generation coil for optimised heat transfer.
INDOOR UNITS
Reduced unit size and weight make this one of the most compact units in its
class on the market.
For power
For economy
To satisfy the needs of shops and offices, where maximium
power is required simultaneously in more than one space,
Carrier offers models with two dedicated compressors each
serving one indoor unit, so that the power of each compressor
is exploited to the full.
Ideal to air-condition spaces where maximum conditioning
power is not usually required simultaneously, such as the daytime and night-time areas of a house, Carrier has developed
the multisplit with split compressor.
Low-ambient device guarantees optimum and safe operation, even at extremely low outside temperatures (down to -15°C for 38GLS/YLS).
42PHQ_S
42VMC
40KMC
40SMC
40DMC
48
49
38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS
FIXED SPEED SPLIT SYSTEM
Flare connections [A]
inch
38GL2M12G
Rotary
Shared
–
15
5
15
331
43
63
590x660x250
39
2
3/8 - 1/4
1/2 - 1/4
Flare connections [B]
inch
-
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
3/8 - 1/4
3/8 - 1/4
A
V-ph-Hz
30
230-1-50
30 + 30
230-1-50
30 + 30
230-1-50
50 + 50
230-1-50
60 + 60
230-1-50
30 + 30
230-1-50
30 + 50
230-1-50
38YY2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
167
45
65
590x800x300
55
2
3/8 - 1/4
3/8 - 1/4
25 + 25
230-1-50
38YY2M21G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15/15
210
48
68
803x800x300
61
2
1/2 - 1/4
1/2 - 1/4
25 + 30
230-1-50
Starting current
Power Supply
Outdoor unit (HP)
Compressor Type
Compressor [A]
Compressor [B]
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units
Flare connections [A]
Flare connections [B]
Starting current
Power Supply
*
[A]
[B]
m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg
m
m
m
g/m
l/s
dB(A)
dB(A)
mm
kg
inch
inch
A
V-ph-Hz
38GL2M18G
Rotary
dedicated
dedicated
15 + 15
5
8+8
15
533
45
65
590x800x300
55
2
3/8 - 1/4
38GL2M24G 38GL2M36G 38GL2M48G 38GL3M21G
Rotary
Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
shared
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
15 + 15
5
10
15
5
8+8
8+8
8+8
8 + 15
15
15
15
15/686
553 + 553
553 + 553
528
48
49
50
46
68
69
70
66
590x800x300 1264x800x300 1264x800x300 590x800x300
64
99
102
58
2
2
2
3
3/8 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
38GL3M30G
Rotary
shared
dedicated
15+30
5
8 + 15
15/553
50
70
803x800x300
75
3
3/8 - 1/4
1/2 - 1/4
38GL4M24G
Rotary
shared
shared
30 + 30
5
15 + 15
15/15
769
50
70
803x800x300
69
4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
230-1-50
38YY2M24G 38YY2M36G 38YY2M48G
Rotary
Rotary
Rotary
dedicated
dedicated
dedicated
dedicated
dedicated
dedicated
15 + 15
30 + 30
40 + 40
5
15
15
8+8
8+8
8+8
15/15
20/20
20/20
210
150
179
48
49
50
68
69
70
803x800x300 1264x800x300 1264x800x300
64
99
102
2
2
2
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
1/2 - 1/4
30 + 30
50 + 50
60 + 60
230-1-50
230-1-50
230-1-50
Sound pressure level in emispheric field at 4 m.
Performances evaluated with 5m interconnecting tubes.
DEDICATED COMPRESSORS
Ultra-reliable compressor. Ideal for both residential and small business applications.
38GL_M/YY_M - AIR-COOLED CONDENSING UNITS
CONTROLS
8 models cooling only from 2kW to 13kW and 5 models in heat pump from 5kW to 14kW
FEATURES
SHARED COMPRESSORS
38GL_M/YY_M FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M
38GL_M/YY_M Multi-split Condensing Unit
Outdoor unit (CO
Compressor Type
Compressor
Compressor
Maximum pipe length
Maximum height difference
Chargeless length
Additional charge
Air flow
Sound pressure level*
Sound power level
Dimensions (H x L x D)
Weight
Max. number of indoor units
Design and components optimised for operation with R410A refrigerant.
Rotary or scroll compressor, synonymous with high reliability and energy efficiency.
Modular control system
ACCESSORIES/OPTIONS
Wall bracket
Low ambient kit
Exceptionally low noise fan.
New generation coil for optimised heat transfer.
INDOOR UNITS
Reduced unit size and weight make this one of the most compact units in its
class on the market.
For power
For economy
To satisfy the needs of shops and offices, where maximium
power is required simultaneously in more than one space,
Carrier offers models with two dedicated compressors each
serving one indoor unit, so that the power of each compressor
is exploited to the full.
Ideal to air-condition spaces where maximum conditioning
power is not usually required simultaneously, such as the daytime and night-time areas of a house, Carrier has developed
the multisplit with split compressor.
Low-ambient device guarantees optimum and safe operation, even at extremely low outside temperatures (down to -15°C for 38GLS/YLS).
42PHQ_S
42VMC
40KMC
40SMC
40DMC
48
49
38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS
FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M
PERFORMANCES 38GL_M (DUAL SPLIT)
PERFORMANCES 38GL_M (TRI SPLIT)
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
38GL2M12G
09+09
38GL2M12G
09+012
38GL2M18G
09+09
38GL2M24G
12+12
38GL2M36G
18+18
38GL2M48G
24+24
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
42PHQ-S
3,80
1550
2,45
E
775
3,81
1570
2,43
E
785
5,31
2170
2,45
E
1085
7,02
2780
2,53
E
1390
10,46
4050
2,58
E
2025
12,60
5220
2,41
na
2610
42VMC-N
3,76
1550
2,43
E
775
3,78
1550
2,44
E
775
4,90
2080
2,36
F
1040
6,89
2730
2,52
E
1365
10,28
3970
2,59
E
1985
12,80
5320
2,41
na
2660
40KMC-N
7,17
2860
2,51
E
1430
10,74
3990
2,69
D
1995
13,20
5300
2,49
na
2650
40SMC-N
3,10
1720
1,80
G
860
3,91
1730
2,26
F
865
5,40
2730
1,98
G
1365
7,00
3040
2,30
F
1520
9,45
4160
2,27
F
2080
12,50
5410
2,31
na
2705
40DMC
10,02
3890
2,58
E
1945
13,00
5500
2,36
na
2750
38GL3M21G
09+09+09
38GL3M21G
09+09+12
38GL3M30G
09+09+18
38GL3M30G
09+12+18
INDOOR UNITS
Operations
38GL2M12G
38GL2M18G
38GL2M24G
38GL2M36G
38GL2M48G
Circuit
B
--------09
12
18
24
Total
3,14
3,25
3,80
3,81
5,31
7,02
10,46
12,60
Cooling Capacity (W)
Circuit A
3,14
3,25
1,90
1,90
1,88
1,93
2,66
3,51
5,23
6,30
Circuit B
--------2,66
3,51
5,23
6,30
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
42PHQ-S
5,86
2360
2,48
E
1180
5,97
2380
2,51
E
1190
8,49
3670
2,31
F
1835
8,55
3690
2,32
F
1845
42VMC-N
5,82
2360
2,47
E
1180
5,86
2380
2,46
E
1190
8,73
3720
2,35
F
1860
8,79
3740
2,35
F
1870
40KMC-N
8,75
3710
2,36
F
1855
8,81
3730
2,36
F
1865
40SMC-N
5,92
2620
2,26
F
1310
5,96
2640
2,26
F
1320
8,40
3720
2,26
F
1860
8,46
3750
2,26
F
1875
40DMC
-
38GL3M30G
09
09
12
09+09
12+09
09+09
09+09+09
09+12+09
09
12
18
09+09
09+18
12+18
09+09+18
09+12+18
Circuit
A
09
--12
09
12
09+09
09+09
09+12
09
12
--09+09
09
12
09+09
09+12
Circuit
B
--09
--09
09
--09
09
----18
--18
18
18
18
Total
2,89
2,32
2,97
5,17
5,25
3,58
5,86
5,90
2,89
2,97
5,47
3,72
7,88
7,96
8,49
8,55
Cooling Capacity (W
Circuit A
2,89
--2,97
2,87
2,95
1,79+1,79
1,78+1,78
1,78+1,82
2,89
2,97
--1,86
1,86
2,87
2,95
1,74
1,74
1,74
1,80
Circuit B
--2,32
--2,30
2,30
--2,30
2,30
----5,47
--5,01
5,01
5,01
5,01
FIXED SPEED SPLIT SYSTEM
INDOOR UNITS COMBINATION
Circuit
A
09
012
09+09
09+012
09
12
18
24
kW
W
W/W
INDOOR UNITS COMBINATION
38GL3M21G
INDOOR UNITS
Operations
09
12
09+09
09+12
09+09
12+12
18+18
24+24
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Data referred to combination with 42PHQ_P
DUAL SPLIT (Cooling)
38GL2M12G
50
38GL2M18G
38GL2M24G
TRI SPLIT
38GL2M36G
38GL2M48G
38GL3M21G
38GL3M30G
51
38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS
FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M
PERFORMANCES 38GL_M (DUAL SPLIT)
PERFORMANCES 38GL_M (TRI SPLIT)
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
38GL2M12G
09+09
38GL2M12G
09+012
38GL2M18G
09+09
38GL2M24G
12+12
38GL2M36G
18+18
38GL2M48G
24+24
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
42PHQ-S
3,80
1550
2,45
E
775
3,81
1570
2,43
E
785
5,31
2170
2,45
E
1085
7,02
2780
2,53
E
1390
10,46
4050
2,58
E
2025
12,60
5220
2,41
na
2610
42VMC-N
3,76
1550
2,43
E
775
3,78
1550
2,44
E
775
4,90
2080
2,36
F
1040
6,89
2730
2,52
E
1365
10,28
3970
2,59
E
1985
12,80
5320
2,41
na
2660
40KMC-N
7,17
2860
2,51
E
1430
10,74
3990
2,69
D
1995
13,20
5300
2,49
na
2650
40SMC-N
3,10
1720
1,80
G
860
3,91
1730
2,26
F
865
5,40
2730
1,98
G
1365
7,00
3040
2,30
F
1520
9,45
4160
2,27
F
2080
12,50
5410
2,31
na
2705
40DMC
10,02
3890
2,58
E
1945
13,00
5500
2,36
na
2750
38GL3M21G
09+09+09
38GL3M21G
09+09+12
38GL3M30G
09+09+18
38GL3M30G
09+12+18
INDOOR UNITS
Operations
38GL2M12G
38GL2M18G
38GL2M24G
38GL2M36G
38GL2M48G
Circuit
B
--------09
12
18
24
Total
3,14
3,25
3,80
3,81
5,31
7,02
10,46
12,60
Cooling Capacity (W)
Circuit A
3,14
3,25
1,90
1,90
1,88
1,93
2,66
3,51
5,23
6,30
Circuit B
--------2,66
3,51
5,23
6,30
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
42PHQ-S
5,86
2360
2,48
E
1180
5,97
2380
2,51
E
1190
8,49
3670
2,31
F
1835
8,55
3690
2,32
F
1845
42VMC-N
5,82
2360
2,47
E
1180
5,86
2380
2,46
E
1190
8,73
3720
2,35
F
1860
8,79
3740
2,35
F
1870
40KMC-N
8,75
3710
2,36
F
1855
8,81
3730
2,36
F
1865
40SMC-N
5,92
2620
2,26
F
1310
5,96
2640
2,26
F
1320
8,40
3720
2,26
F
1860
8,46
3750
2,26
F
1875
40DMC
-
38GL3M30G
09
09
12
09+09
12+09
09+09
09+09+09
09+12+09
09
12
18
09+09
09+18
12+18
09+09+18
09+12+18
Circuit
A
09
--12
09
12
09+09
09+09
09+12
09
12
--09+09
09
12
09+09
09+12
Circuit
B
--09
--09
09
--09
09
----18
--18
18
18
18
Total
2,89
2,32
2,97
5,17
5,25
3,58
5,86
5,90
2,89
2,97
5,47
3,72
7,88
7,96
8,49
8,55
Cooling Capacity (W
Circuit A
2,89
--2,97
2,87
2,95
1,79+1,79
1,78+1,78
1,78+1,82
2,89
2,97
--1,86
1,86
2,87
2,95
1,74
1,74
1,74
1,80
Circuit B
--2,32
--2,30
2,30
--2,30
2,30
----5,47
--5,01
5,01
5,01
5,01
FIXED SPEED SPLIT SYSTEM
INDOOR UNITS COMBINATION
Circuit
A
09
012
09+09
09+012
09
12
18
24
kW
W
W/W
INDOOR UNITS COMBINATION
38GL3M21G
INDOOR UNITS
Operations
09
12
09+09
09+12
09+09
12+12
18+18
24+24
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Data referred to combination with 42PHQ_P
DUAL SPLIT (Cooling)
38GL2M12G
50
38GL2M18G
38GL2M24G
TRI SPLIT
38GL2M36G
38GL2M48G
38GL3M21G
38GL3M30G
51
38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS
FIXED SPEED SPLIT SYSTEM
38GL4M24G
'09+09+09+09
38GL4M24G
09+09+09+12
38GL4M24G
09+12+09+12
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
PERFORMANCES 38YY_M (DUAL SPLIT HEATING)
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
42PHQ_S
6,96
2760
2,52
E
1380
7,00
2790
2,51
E
1395
7,04
2840
2,48
E
1420
42VMC-N
7,02
2750
2,55
E
1375
7,05
2780
2,54
E
1390
7,10
2810
2,53
E
1405
40KMC-N
6,98
2740
2,55
E
1370
7,02
2810
2,50
E
1405
40SMC-N
7,13
3070
2,32
F
1535
7,17
3100
2,31
F
1550
7,21
3150
2,29
F
1575
40DMC
-
38GL4M24G
09
12
09+09
09+09
09+12
09+12
12+12
09+09+09
09+09+12
09+09+12
09+12+12
09+09+09+09
09+09+09+12
09+12+09+12
38YY2M21G
09+12
38YY2M24G
12+12
INDOOR UNITS COMBINATION
INDOOR UNITS
Operations
38YY2M18G
09+09
Circuit
A
09
12
09+09
09
09+012
09
12
09+09
09+12
09+09
09+12
09+09
09+09
09+12
Circuit
B
------09
--12
12
09
09
12
12
09+09
09+12
09+12
Total
2,83
2,87
3,60
5,42
3,64
5,47
5,50
6,22
6,26
6,26
6,30
6,96
7,00
7,04
1,80
1,80
1,74
1,74
1,74
1,74
1,74
1,74
1,74
Cooling Capacity (W
Circuit A
2,83
2,87
1,80
2,71
1,84
2,71
2,75
1,74
1,78
1,74
1,78
1,74
1,74
1,78
Circuit B
------2,71
--2,76
2,75
2,74
2,74
2,78
2,78
1,74
1,74
1,74
38YY2M36G
38YYS2M36G
18+18
1,74
1,78
1,78
38YY2M48G
38YYS2M48G
24+24
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
QUADRI SPLIT
38GL4M24G
52
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
42PHQ_S
5,55
2080
2,67
D
1040
5,83
1860
3,13
D
6,45
2310
2,79
D
1155
6,95
2300
3,02
D
6,80
2660
2,56
E
1330
7,05
2460
2,87
D
9,87
3770
2,62
D
1885
10,60
3490
3,04
D
12,10
4900
2,47
na
2450
14,20
5220
2,72
na
42VMC-N
5,29
1930
2,74
D
965
5,58
1970
2,83
D
6,16
2180
2,83
C
1090
6,67
2420
2,76
E
6,50
2510
2,59
E
1255
6,80
2550
2,67
E
10,00
3890
2,57
E
1945
10,90
3650
2,99
D
13,00
5080
2,56
na
2540
13,80
5360
2,57
na
40KMC-N
6,62
2640
2,51
E
1320
6,96
2490
2,80
E
9,78
3850
2,54
E
1925
11,5
3650
3,15
D
12,7
4980
2,55
na
2490
13,6
5400
2,52
na
40SMC-N
5,05
2140
2,36
F
1070
5,48
2080
2,63
E
5,84
2440
2,39
F
1220
6,47
2540
2,55
F
6,12
2860
2,14
G
1430
6,50
2660
2,44
F
9,23
3960
2,33
F
1980
10,40
3930
2,65
E
12,08
4560
2,65
na
2280
14,20
5000
2,84
na
40DMC
9,95
3750
2,65
D
1875
10,80
3350
3,22
C
13,20
4920
2,68
na
2460
14,20
4800
2,96
na
38GL_M/YY_M FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M
PERFORMANCES 38GL_M (QUADRI SPLIT)
DUAL SPLIT
38YY2M18G
38YY2M21G
38YY2M24G
38YY2M36G
38YY2M48G
53
38GL_M/YY_M - MULTI-SPLIT CONDENSING UNITS
FIXED SPEED SPLIT SYSTEM
38GL4M24G
'09+09+09+09
38GL4M24G
09+09+09+12
38GL4M24G
09+12+09+12
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
Cooling Capacity
Power Input
EER
Energy efficiency class
Annual energy consumption
PERFORMANCES 38YY_M (DUAL SPLIT HEATING)
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kWh
42PHQ_S
6,96
2760
2,52
E
1380
7,00
2790
2,51
E
1395
7,04
2840
2,48
E
1420
42VMC-N
7,02
2750
2,55
E
1375
7,05
2780
2,54
E
1390
7,10
2810
2,53
E
1405
40KMC-N
6,98
2740
2,55
E
1370
7,02
2810
2,50
E
1405
40SMC-N
7,13
3070
2,32
F
1535
7,17
3100
2,31
F
1550
7,21
3150
2,29
F
1575
40DMC
-
38GL4M24G
09
12
09+09
09+09
09+12
09+12
12+12
09+09+09
09+09+12
09+09+12
09+12+12
09+09+09+09
09+09+09+12
09+12+09+12
38YY2M21G
09+12
38YY2M24G
12+12
INDOOR UNITS COMBINATION
INDOOR UNITS
Operations
38YY2M18G
09+09
Circuit
A
09
12
09+09
09
09+012
09
12
09+09
09+12
09+09
09+12
09+09
09+09
09+12
Circuit
B
------09
--12
12
09
09
12
12
09+09
09+12
09+12
Total
2,83
2,87
3,60
5,42
3,64
5,47
5,50
6,22
6,26
6,26
6,30
6,96
7,00
7,04
1,80
1,80
1,74
1,74
1,74
1,74
1,74
1,74
1,74
Cooling Capacity (W
Circuit A
2,83
2,87
1,80
2,71
1,84
2,71
2,75
1,74
1,78
1,74
1,78
1,74
1,74
1,78
Circuit B
------2,71
--2,76
2,75
2,74
2,74
2,78
2,78
1,74
1,74
1,74
38YY2M36G
38YYS2M36G
18+18
1,74
1,78
1,78
38YY2M48G
38YYS2M48G
24+24
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
Cooling Capacity
Power input (CO)
EER
Energy efficiency class(CO)
Annual energy consumption
Heating capacity
Power input (HP)
COP
Energy efficiency class (HP)
QUADRI SPLIT
38GL4M24G
52
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
kWh
kW
W
W/W
kWh
kW
W
W/W
kW
W
W/W
42PHQ_S
5,55
2080
2,67
D
1040
5,83
1860
3,13
D
6,45
2310
2,79
D
1155
6,95
2300
3,02
D
6,80
2660
2,56
E
1330
7,05
2460
2,87
D
9,87
3770
2,62
D
1885
10,60
3490
3,04
D
12,10
4900
2,47
na
2450
14,20
5220
2,72
na
42VMC-N
5,29
1930
2,74
D
965
5,58
1970
2,83
D
6,16
2180
2,83
C
1090
6,67
2420
2,76
E
6,50
2510
2,59
E
1255
6,80
2550
2,67
E
10,00
3890
2,57
E
1945
10,90
3650
2,99
D
13,00
5080
2,56
na
2540
13,80
5360
2,57
na
40KMC-N
6,62
2640
2,51
E
1320
6,96
2490
2,80
E
9,78
3850
2,54
E
1925
11,5
3650
3,15
D
12,7
4980
2,55
na
2490
13,6
5400
2,52
na
40SMC-N
5,05
2140
2,36
F
1070
5,48
2080
2,63
E
5,84
2440
2,39
F
1220
6,47
2540
2,55
F
6,12
2860
2,14
G
1430
6,50
2660
2,44
F
9,23
3960
2,33
F
1980
10,40
3930
2,65
E
12,08
4560
2,65
na
2280
14,20
5000
2,84
na
40DMC
9,95
3750
2,65
D
1875
10,80
3350
3,22
C
13,20
4920
2,68
na
2460
14,20
4800
2,96
na
38GL_M/YY_M FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 38GL_M/YY_M
PERFORMANCES 38GL_M (QUADRI SPLIT)
DUAL SPLIT
38YY2M18G
38YY2M21G
38YY2M24G
38YY2M36G
38YY2M48G
53
CONTROLS RANGE
KIT FOR SATELLITE UNITS
LOCAL WIRED CONTROL
BUILDING MANAGEMENT
ROOM CONTROLLER 33MC-RC
ZONE MANAGER 33MC-ZM
Wall receiver for ducted satellite units Fixed speed
and XPower inverter.
MAIN FUNCTIONS:
1 x
6
WIRED CONTROL FOR SINGLE APPLICATIONS:
8 x
This small and elegant wall mounted control serves up to 6 unitswith
the same operating setting.
32
SYSTEMS MONITORING:
This building supervisor can control and set schedules up to 32 different indoors units in 8 indipendent zones.
CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS
DIRECT EXPANSION SPLIT SYSTEMS CONTROLS RANGE
DIRECT EXPANSION SPLIT SYSTEMS
ALUMINIUM COLOR
The basic and most used buttons are ergonomically placed for intuitive
and user friendly operations.
MY COMFORT:
Allows selection and memorization of the favourite end-user setting via
the remote control.
LIQUID CRYSTAL DISPLAY:
WEEKLY PROGRAMMING
All settings and operation paremeters clearly displayed.
User can select four individual start/stop ranges per day of the week
for each zone.
EASY MODE AND FAN SELECTION BUTTON:
ZONE SETTINGS AND LOCAL OPERATION:
Quick choice between cooling, heating, dehumidification, fan only or
auto.
Any individual unit within each zone can be operated by the end-user
according to his desires by overiding zone setting.
GROUPING FUNCTIONALITY:
AUTONOMOUS OPERATION:
This control is suitable to operate up to 6 units located in the same
zone. ( 1 accessoty usable for up to 5 slave units is required for proper
installation of 33MC9002).
If power failure occurs, clock operations are maintained for up to 20
hours, while programmed parameters are kept in the memory.
EXTRA POWER:
With this setting the fan will run at maximum speed and the setpoint
will be reached quickly.
IONIZER:
The ionizer can be operated separately, to deliver millions of negative
ions in the ambient and give an immediate sensation of well-being.
Available for XPower sensation (42PQV_S) in style
with the unit design.
ECONOMY:
The unit will work at low speed for maximum energy saving and silent
operation.
LOUVRE CONTROL:
HiWall
Fixed speed
Inverter
54
42PQV (LC)
Air flow direction can be remotely adjusted to optimized the air flow
distribution and suit individual preferences.
Console
Cassette
Satellite
42VMC
40KMC
40SMC
40DMC
PROGRAMMING FUNCTIONS:
42VQV
40KQV
40SQV
40DQV
Clock and 24 hours timer, sleep mode or continous programming settings are easily available.
Function may vary depending on the unit
55
CONTROLS RANGE
KIT FOR SATELLITE UNITS
LOCAL WIRED CONTROL
BUILDING MANAGEMENT
ROOM CONTROLLER 33MC-RC
ZONE MANAGER 33MC-ZM
Wall receiver for ducted satellite units Fixed speed
and XPower inverter.
MAIN FUNCTIONS:
1 x
6
WIRED CONTROL FOR SINGLE APPLICATIONS:
8 x
This small and elegant wall mounted control serves up to 6 unitswith
the same operating setting.
32
SYSTEMS MONITORING:
This building supervisor can control and set schedules up to 32 different indoors units in 8 indipendent zones.
CONTROLS RANGE DIRECT EXPANSION SPLIT SYSTEMS
DIRECT EXPANSION SPLIT SYSTEMS CONTROLS RANGE
DIRECT EXPANSION SPLIT SYSTEMS
ALUMINIUM COLOR
The basic and most used buttons are ergonomically placed for intuitive
and user friendly operations.
MY COMFORT:
Allows selection and memorization of the favourite end-user setting via
the remote control.
LIQUID CRYSTAL DISPLAY:
WEEKLY PROGRAMMING
All settings and operation paremeters clearly displayed.
User can select four individual start/stop ranges per day of the week
for each zone.
EASY MODE AND FAN SELECTION BUTTON:
ZONE SETTINGS AND LOCAL OPERATION:
Quick choice between cooling, heating, dehumidification, fan only or
auto.
Any individual unit within each zone can be operated by the end-user
according to his desires by overiding zone setting.
GROUPING FUNCTIONALITY:
AUTONOMOUS OPERATION:
This control is suitable to operate up to 6 units located in the same
zone. ( 1 accessoty usable for up to 5 slave units is required for proper
installation of 33MC9002).
If power failure occurs, clock operations are maintained for up to 20
hours, while programmed parameters are kept in the memory.
EXTRA POWER:
With this setting the fan will run at maximum speed and the setpoint
will be reached quickly.
IONIZER:
The ionizer can be operated separately, to deliver millions of negative
ions in the ambient and give an immediate sensation of well-being.
Available for XPower sensation (42PQV_S) in style
with the unit design.
ECONOMY:
The unit will work at low speed for maximum energy saving and silent
operation.
LOUVRE CONTROL:
HiWall
Fixed speed
Inverter
54
42PQV (LC)
Air flow direction can be remotely adjusted to optimized the air flow
distribution and suit individual preferences.
Console
Cassette
Satellite
42VMC
40KMC
40SMC
40DMC
PROGRAMMING FUNCTIONS:
42VQV
40KQV
40SQV
40DQV
Clock and 24 hours timer, sleep mode or continous programming settings are easily available.
Function may vary depending on the unit
55
42HQE_G - HIGH-WALL UNITS
FIXED SPEED SPLIT SYSTEM
42HQE_G
42HQE009G
38YE009G
42HQE012G
38YE012G
Cooling capacity (CO)
kW
2,5
3,5
Power Input (CO)
W
889
1245
W/W
2,81
2,81
E.E.R.
Energy efficiency class (CO)
C
C
445
623
Annual Energy Consumption
kWh
Heating Capacity
kW
2,9
4,0
Power Input (HP)
W
903
1246
W/W
3,21
3,21
C
C
009
012
C.O.P.
Energy Efficiency Class (HP)
Indoor unit
Dehumidification
l/h
1,0
1,2
Nominal air flow (l/m/h)
l/s
97/110/125
105/130/178
Sound pressure (l/m/h)
dB(A)*
33/36/39
32/35/42
Sound power (l/m/h)
dB(A)
47/49/52
45/48/55
Dimensions (HxLxD)
mm
250x750x188
280x815x195
Weight
Power Supply
kg
8,5
10,5
V-ph-Hz
230-1-50
230-1-50
Outdoor unit (HP)
009
012
Compressor Type
Rotary
Rotary
Maximum pipe length
m
10
10
Maximum height difference
m
5
5
Chargeless
m
5
5
dB(A)**
40
41
Sound pressure
Sound power
dB(A)
60
61
Dimensions (HxLxD)
mm
535x700x235
540x780x250
Weight
kg
Flare Connections
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
Performances evaluated with 5m interconnecting tubes and according to EN14511.
V-ph-Hz
28
35
1/4" - 3/8"
1/4" - 1/2"
230-1-50
230-1-50
IN
Four products in one: dehumidifier, heater, air
conditioner and fan. A product to use in every
season.
42HQE_G FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42HQE_G
Indoor unit
Outdoor unit (HP)
42HQE_G - HIGH-WALL UNITS
Allegro Plus is the friendly air-conditioner that refreshes in summer and
provides warm in winter. The ideal companion throughout the years.
CONTROLS
2 sizes heat pump from: 2,5 kW to 3,5 kW in cooling; 2,9 kW to 4,0 kW in heating.
FEATURES
Modern and trendy design thanks to its simple lines.
Allegro Plus uses R410A, the no ozone depleting refrigerant for better performances.
Programmable timer
Easy to use remote control for a quick programming of well-being. The wide
display gives a clear and precise view of the active setting.
The active carbon filter eliminates bacteria and bad odours.
Customised air flow thanks to the adjustable louvers.
OUTDOOR UNITS
The outdoor unit coils fins have been treated with blue-fin anti-corrosion coating.
Outdoor unit the connections are protected by a protective shield; a feature not
common in similar products..
VDE safety mark, worldwide recognised for reliability.
All data are Eurovent certified.
38YE_G
56
57
42HQE_G - HIGH-WALL UNITS
FIXED SPEED SPLIT SYSTEM
42HQE_G
42HQE009G
38YE009G
42HQE012G
38YE012G
Cooling capacity (CO)
kW
2,5
3,5
Power Input (CO)
W
889
1245
W/W
2,81
2,81
E.E.R.
Energy efficiency class (CO)
C
C
445
623
Annual Energy Consumption
kWh
Heating Capacity
kW
2,9
4,0
Power Input (HP)
W
903
1246
W/W
3,21
3,21
C
C
009
012
C.O.P.
Energy Efficiency Class (HP)
Indoor unit
Dehumidification
l/h
1,0
1,2
Nominal air flow (l/m/h)
l/s
97/110/125
105/130/178
Sound pressure (l/m/h)
dB(A)*
33/36/39
32/35/42
Sound power (l/m/h)
dB(A)
47/49/52
45/48/55
Dimensions (HxLxD)
mm
250x750x188
280x815x195
Weight
Power Supply
kg
8,5
10,5
V-ph-Hz
230-1-50
230-1-50
Outdoor unit (HP)
009
012
Compressor Type
Rotary
Rotary
Maximum pipe length
m
10
10
Maximum height difference
m
5
5
Chargeless
m
5
5
dB(A)**
40
41
Sound pressure
Sound power
dB(A)
60
61
Dimensions (HxLxD)
mm
535x700x235
540x780x250
Weight
kg
Flare Connections
Power Supply
*
**
Sound pressure level in a free field according to JIS9612 Standard.
Sound pressure level in emispheric field at 4 m.
Performances evaluated with 5m interconnecting tubes and according to EN14511.
V-ph-Hz
28
35
1/4" - 3/8"
1/4" - 1/2"
230-1-50
230-1-50
IN
Four products in one: dehumidifier, heater, air
conditioner and fan. A product to use in every
season.
42HQE_G FIXED SPEED SPLIT SYSTEM
FIXED SPEED SPLIT SYSTEM 42HQE_G
Indoor unit
Outdoor unit (HP)
42HQE_G - HIGH-WALL UNITS
Allegro Plus is the friendly air-conditioner that refreshes in summer and
provides warm in winter. The ideal companion throughout the years.
CONTROLS
2 sizes heat pump from: 2,5 kW to 3,5 kW in cooling; 2,9 kW to 4,0 kW in heating.
FEATURES
Modern and trendy design thanks to its simple lines.
Allegro Plus uses R410A, the no ozone depleting refrigerant for better performances.
Programmable timer
Easy to use remote control for a quick programming of well-being. The wide
display gives a clear and precise view of the active setting.
The active carbon filter eliminates bacteria and bad odours.
Customised air flow thanks to the adjustable louvers.
OUTDOOR UNITS
The outdoor unit coils fins have been treated with blue-fin anti-corrosion coating.
Outdoor unit the connections are protected by a protective shield; a feature not
common in similar products..
VDE safety mark, worldwide recognised for reliability.
All data are Eurovent certified.
38YE_G
56
57
73FC/XC/YC - WINDOW UNIT
ROOM AIR CONDITIONERS
73Series
XCY127DR
XCP187DR
kW
2,6
3,5
5,2
6,7
Power Input
W
945
1200
2110
2720
W/W
2,75
2,92
2,46
2,46
C
B
D
D
473
600
1055
1360
ROOM AIR CONDITIONERS 73FC/XC/YC
EER
Energy efficiency class
Annual energy consumption
Dehumidification
l/h
0,7
1,6
2,4
3,3
Air flow*
l/s
103
188
217
283
Dimensions (H x L x D)
mm
330x600x470
425x640x610
425x640x610
445x712x600
Weight
Power Supply
*
kWh
YCN247DR
kg
28
52
55
72
V-ph-Hz
220-1-50
220-1-50
220-1-50
220-1-50
SILENTIA
High speed.
Extremely quiet and very energy-efficient.
73FC/XC/YC ROOM AIR CONDITIONERS
FCC097RB
Cooling Capacity
Model
73FC/XC/YC - WINDOW UNIT
The new Carrier range features up-to-date design and superior energysaving performance.
CONTROLS
FEATURES
Powerful, compact unit - 30% smaller than other comparable units.
Uniform air distribution pattern and quiet operation make these units an obvious
choice for optimum comfort day after day.
Superior efficiency for ultimate comfort.
Just four models covering most requirements up to 7 kW.
All units are equipped with infrared remote control.
COMPACT
Powerful, compact unit.
30% smaller than other comparable units.
73FC
58
73XC/YC
59
73FC/XC/YC - WINDOW UNIT
ROOM AIR CONDITIONERS
73Series
XCY127DR
XCP187DR
kW
2,6
3,5
5,2
6,7
Power Input
W
945
1200
2110
2720
W/W
2,75
2,92
2,46
2,46
C
B
D
D
473
600
1055
1360
ROOM AIR CONDITIONERS 73FC/XC/YC
EER
Energy efficiency class
Annual energy consumption
Dehumidification
l/h
0,7
1,6
2,4
3,3
Air flow*
l/s
103
188
217
283
Dimensions (H x L x D)
mm
330x600x470
425x640x610
425x640x610
445x712x600
Weight
Power Supply
*
kWh
YCN247DR
kg
28
52
55
72
V-ph-Hz
220-1-50
220-1-50
220-1-50
220-1-50
SILENTIA
High speed.
Extremely quiet and very energy-efficient.
73FC/XC/YC ROOM AIR CONDITIONERS
FCC097RB
Cooling Capacity
Model
73FC/XC/YC - WINDOW UNIT
The new Carrier range features up-to-date design and superior energysaving performance.
CONTROLS
FEATURES
Powerful, compact unit - 30% smaller than other comparable units.
Uniform air distribution pattern and quiet operation make these units an obvious
choice for optimum comfort day after day.
Superior efficiency for ultimate comfort.
Just four models covering most requirements up to 7 kW.
All units are equipped with infrared remote control.
COMPACT
Powerful, compact unit.
30% smaller than other comparable units.
73FC
58
73XC/YC
59
51AKE / AKB / AKC - PORTABLES
51AKE / AKB / AKC
51AKE 065
51AKB 065
51AKB 085
51AKB 010
Cooling Capacity
kW
1,71
1,71
2,1
2,6
3,35
Power Input
W
630
630
820
850
1190
W/W
2,71
2,71
2,56
3,06
2,82
A
A
B
B
C
315
315
410
425
595
Indoor unit
EER
Energy class
Annual energy consumption
Dehumidification
l/h
0,75
0,75
1,1
1,4
1,9
Air flow (l/h)
l/s
75/90
75/90
75/90
133/104
133/104
Sound pressure level IU (l/h)
dB(A)
46/48
46/48
46/48
46/43
46/43
Sound pressure level OU
dB(A)
-
-
-
50
50
Dimensions IU (H x L x D)
mm
850x440x350
850x440x350
850x440x350
850x440x350
850x440x350
Weight IU
kg
28
28
28,5
30
35
Dimensions OU (H x L x D)
mm
-
-
-
430x413x230
430x413x230
Weight OU
kg
-
-
-
11,5
11,5
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Air discharge tube, max. length
mm
1100
1100
1100
-
-
Interconnecting Pipe Length
mm
-
-
-
1800
3600*
A
3,2
3,2
4,4
4,4
5,8
Power Supply
Electric heater current
*
kWh
51AKC 013
IN
Three products in one: air conditioner, dehumidifier with easy-to-empty water tank and fan. A
product for all seasons.
with quick couplings.
Performance data according to EN14511.
51AKE / AKB / AKC ROOM AIR CONDITIONERS
ROOM AIR CONDITIONERS 51AKE / AKB / AKC
ROOM AIR CONDITIONERS
51AKE / AKB / AKC - PORTABLES
The portable Holiday units offer exceptional versatility combined with style
to ensure optimum individual comfort in both residential rooms and single
offices up to 40m.
CONTROLS
51AKE
FEATURES
Practical and intuitive - the mechanical interface is easy to use.
Small but powerful - small and light in weight, but very efficient at the same
time.
Up to 1.6 l/h dehumidification capacity. Condensate collected in an easy-toempty tank.
51AKB
51AKB/C
ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit
The energy consumption is much lower than that of a microwave oven or iron.
Removing the condensate is no problem thanks to the removable tank; no
pipes or sinks required.
Split units are available with quick couplings for installation flexibility.
Fully ecological - units use R-407C or R-410A refrigerant and have 100% recyclable packaging.
CASTORS INCLUDED
Monobloc and split versions - one of the smallest and lightest portable air conditioners on the market.
51 AKE 065
60
51AKB 065
51AKB 085
52AKB 010
53AKB 013
Easily movable from room to room with minimum effort.
61
51AKE / AKB / AKC - PORTABLES
51AKE / AKB / AKC
51AKE 065
51AKB 065
51AKB 085
51AKB 010
Cooling Capacity
kW
1,71
1,71
2,1
2,6
3,35
Power Input
W
630
630
820
850
1190
W/W
2,71
2,71
2,56
3,06
2,82
A
A
B
B
C
315
315
410
425
595
Indoor unit
EER
Energy class
Annual energy consumption
Dehumidification
l/h
0,75
0,75
1,1
1,4
1,9
Air flow (l/h)
l/s
75/90
75/90
75/90
133/104
133/104
Sound pressure level IU (l/h)
dB(A)
46/48
46/48
46/48
46/43
46/43
Sound pressure level OU
dB(A)
-
-
-
50
50
Dimensions IU (H x L x D)
mm
850x440x350
850x440x350
850x440x350
850x440x350
850x440x350
Weight IU
kg
28
28
28,5
30
35
Dimensions OU (H x L x D)
mm
-
-
-
430x413x230
430x413x230
Weight OU
kg
-
-
-
11,5
11,5
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Air discharge tube, max. length
mm
1100
1100
1100
-
-
Interconnecting Pipe Length
mm
-
-
-
1800
3600*
A
3,2
3,2
4,4
4,4
5,8
Power Supply
Electric heater current
*
kWh
51AKC 013
IN
Three products in one: air conditioner, dehumidifier with easy-to-empty water tank and fan. A
product for all seasons.
with quick couplings.
Performance data according to EN14511.
51AKE / AKB / AKC ROOM AIR CONDITIONERS
ROOM AIR CONDITIONERS 51AKE / AKB / AKC
ROOM AIR CONDITIONERS
51AKE / AKB / AKC - PORTABLES
The portable Holiday units offer exceptional versatility combined with style
to ensure optimum individual comfort in both residential rooms and single
offices up to 40m.
CONTROLS
51AKE
FEATURES
Practical and intuitive - the mechanical interface is easy to use.
Small but powerful - small and light in weight, but very efficient at the same
time.
Up to 1.6 l/h dehumidification capacity. Condensate collected in an easy-toempty tank.
51AKB
51AKB/C
ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit
The energy consumption is much lower than that of a microwave oven or iron.
Removing the condensate is no problem thanks to the removable tank; no
pipes or sinks required.
Split units are available with quick couplings for installation flexibility.
Fully ecological - units use R-407C or R-410A refrigerant and have 100% recyclable packaging.
CASTORS INCLUDED
Monobloc and split versions - one of the smallest and lightest portable air conditioners on the market.
51 AKE 065
60
51AKB 065
51AKB 085
52AKB 010
53AKB 013
Easily movable from room to room with minimum effort.
61
51AKS - PORTABLES
ROOM AIR CONDITIONERS
51AKS Portables
51AKS185
kW
2,1
2,1
2,6
2,6
3,35
3,35
3,35
3,77
Power Input
W
820
820
850
850
1190
1190
1190
1500
W/W
2,56
2,56
3,06
3,06
2,82
2,82
2,82
2,51
B
B
B
B
C
C
C
E
410
410
425
425
595
595
595
750
EER
ROOM AIR CONDITIONERS 51AKS
Energy class
Annual energy consumption
51AKS113
51AKS015C-P
Dehumidification
l/h
1,1
1,1
1,4
1,4
1,9
1,9
1,9
2,7
Air flow (l/h)
l/s
75/90
75/90
133/104
133/104
133/104
133/104
133/104
133/104
Sound pressure level IU (l/h)
dB(A)
46/48
46/48
46/43
46/43
46/43
46/43
46/43
46/44
Sound pressure level OU
dB(A)
-
-
50
50
50
50
50
50
Dimensions IU (H x L x D)
mm
850x440x390 850x440x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390
Weight IU
kg
28,5
28,5
Dimensions OU (H x L x D)
mm
-
-
Weight OU
30,0
30,0
36
36
36
36
430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230
kg
-
-
11,5
11,5
11,5
11,5
11,5
11,5
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Air discharge tube, max. length
mm
1100
1100
-
-
-
-
-
-
Interconnecting Pipe Length
mm
-
-
1800
3600*
1800
3600*
1800
3600*
Electric heater capacity
Power Supply
*
kWh
51AKS010-P 51AKS010C-P 51AKS013-P 51AKS013C-P
kW
-
1,6
-
-
-
-
1,6
-
Current drawn (cooling mode)
A
4,4
4,4
4,4
4,4
5,8
5,8
5,8
6,8
Current drawn (heating mode)
A
-
7,0
-
-
-
-
7,0
-
Up to four products in one: air conditioner,
dehumidifier with removable water tank, fan
and heater (see detail). A product for all four
seasons.
with quick couplings.
Performance data according to EN14511.
51AKS ROOM AIR CONDITIONERS
51AKS085
Cooling Capacity
Indoor unit
51AKS - PORTABLES
The 51AKS is the elegant ready-to-use solution for use in different rooms
at home or in the office.
CONTROLS
FEATURES
51AKS
Electronic interface - advanced, immediate and intuitive technology allows easy
and precise programming of personal comfort conditions.
Choice of various capacity and colour combinations to suit all user requirements.
Minimal noise levels for ultra-quiet operation, essential for total relaxation.
ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit
Sleep function - the lights are dimmed, fresh air is supplied at a soft whisper:
ideal conditions for relaxed sleep and sweet dreams.
Precise and powerful humidity control - with eight dehumidification levels and a
removable tank, the split version removes up to 65 litres of water per day from
the air.
Extra compact and light - easy-to-move and not intrusive, blends in with any
room surroundings.
BENCHMARK
Removing the condensate is no problem thanks to the removable tank; no
pipes or sinks required.
51AKS 085
51AKS 185
62
51AKS 085-P
51AKS 085 AL
51AKS 010 P
51AKS 010 C-P
51AKS 013 P
51AKS 013 C-P
51AKS 015 C-P
51AKS 113
The smallest outdoor unit on the market
63
51AKS - PORTABLES
ROOM AIR CONDITIONERS
51AKS Portables
51AKS185
kW
2,1
2,1
2,6
2,6
3,35
3,35
3,35
3,77
Power Input
W
820
820
850
850
1190
1190
1190
1500
W/W
2,56
2,56
3,06
3,06
2,82
2,82
2,82
2,51
B
B
B
B
C
C
C
E
410
410
425
425
595
595
595
750
EER
ROOM AIR CONDITIONERS 51AKS
Energy class
Annual energy consumption
51AKS113
51AKS015C-P
Dehumidification
l/h
1,1
1,1
1,4
1,4
1,9
1,9
1,9
2,7
Air flow (l/h)
l/s
75/90
75/90
133/104
133/104
133/104
133/104
133/104
133/104
Sound pressure level IU (l/h)
dB(A)
46/48
46/48
46/43
46/43
46/43
46/43
46/43
46/44
Sound pressure level OU
dB(A)
-
-
50
50
50
50
50
50
Dimensions IU (H x L x D)
mm
850x440x390 850x440x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390 850x490x390
Weight IU
kg
28,5
28,5
Dimensions OU (H x L x D)
mm
-
-
Weight OU
30,0
30,0
36
36
36
36
430x413x230 430x413x230 430x413x230 430x413x230 430x413x230 430x413x230
kg
-
-
11,5
11,5
11,5
11,5
11,5
11,5
V-ph-Hz
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
230-1-50
Air discharge tube, max. length
mm
1100
1100
-
-
-
-
-
-
Interconnecting Pipe Length
mm
-
-
1800
3600*
1800
3600*
1800
3600*
Electric heater capacity
Power Supply
*
kWh
51AKS010-P 51AKS010C-P 51AKS013-P 51AKS013C-P
kW
-
1,6
-
-
-
-
1,6
-
Current drawn (cooling mode)
A
4,4
4,4
4,4
4,4
5,8
5,8
5,8
6,8
Current drawn (heating mode)
A
-
7,0
-
-
-
-
7,0
-
Up to four products in one: air conditioner,
dehumidifier with removable water tank, fan
and heater (see detail). A product for all four
seasons.
with quick couplings.
Performance data according to EN14511.
51AKS ROOM AIR CONDITIONERS
51AKS085
Cooling Capacity
Indoor unit
51AKS - PORTABLES
The 51AKS is the elegant ready-to-use solution for use in different rooms
at home or in the office.
CONTROLS
FEATURES
51AKS
Electronic interface - advanced, immediate and intuitive technology allows easy
and precise programming of personal comfort conditions.
Choice of various capacity and colour combinations to suit all user requirements.
Minimal noise levels for ultra-quiet operation, essential for total relaxation.
ACCESSORIES
Set of three porthole covers
IAQ (indoor air quality) filter kit
Sleep function - the lights are dimmed, fresh air is supplied at a soft whisper:
ideal conditions for relaxed sleep and sweet dreams.
Precise and powerful humidity control - with eight dehumidification levels and a
removable tank, the split version removes up to 65 litres of water per day from
the air.
Extra compact and light - easy-to-move and not intrusive, blends in with any
room surroundings.
BENCHMARK
Removing the condensate is no problem thanks to the removable tank; no
pipes or sinks required.
51AKS 085
51AKS 185
62
51AKS 085-P
51AKS 085 AL
51AKS 010 P
51AKS 010 C-P
51AKS 013 P
51AKS 013 C-P
51AKS 015 C-P
51AKS 113
The smallest outdoor unit on the market
63
54DHS - DEHUMIDIFIERS
ROOM AIR CONDITIONERS
54DHS Dehumidifiers
Carrier model n°
54DHS014
54DHS018
54DHS018HE
lt
11
14
18
18
24
Power consumption a 27°C, 60% RH
W
205
232
410
410
410
1
2
2
2
2
m3/h
100
110
160
160
180
lt
7
Fan speeds
ROOM AIR CONDITIONERS 54DHS
Air flow
Tank capacity
54DHS024
6
6
7
7
Deodorizing filters
–
Yes
–
–
–
Antibacterial filters
–
–
Yes
Yes
Yes
Electric heater
–
–
–
Yes
–
Continuos drain hose connection
W
Yes
Yes
Yes
Yes
Yes
Container full light and auto shut off
Yes
Yes
Yes
Yes
Yes
Defrost
Yes
Yes
Yes
Yes
Yes
Electronic humidistat
Yes
Yes
Yes
Yes
Yes
Digital control
–
–
–
Yes
Yes
Castors
Yes
Yes
Yes
Yes
Yes
Transporting handle
Yes
Yes
Yes
Yes
Yes
°C
5-35
5-35
5-35
5-35
5-35
R134A
R134A
R134A
R134A
R134A
Size (W x H x D)
mm
325x540x355
325x540x355
345x722x352
345x722x352
345x722x352
Weight
kg
15
15,5
19,5
19,5
22
Working limits
Refrigerant
°C
The new “Comfort dehumidifyng” function
selects automatically the right level of humidity in relative to temperature variations.
(Idealday 24)
54DHS ROOM AIR CONDITIONERS
54DHS011
Capacity
*tested by EU directive CEE 73/23/CE
54DHS - DEHUMIDIFIERS
Idealday is the name, as these units offer the ideal solution for excess
humidity removal from your environment, preserving walls, furniture and
your health.
FEATURES
WHY IS IT SO IMPORTANT TO CONTROL THE HUMIDITY LEVEL?
Too much humidity damages your health and the furniture in the house. It harms people,
aggravating conditions like asthma, arthritis and rheumatism. High humidity levels cause
mould on the walls and damps patches, and spool surfaces. Humidity should be controlled
all year long, especially in rainy autumns and in humid summers.
CONTROLS
54DHS11
54DHS14
Special antibacterial filter to prevent growth of bacteria and form of mould for
purer and healthier environments. (Idealday 24 and 18HE)
Electronic control with multifunctional liquid crystal display with clock and timer
function for a precise regulation of the humidity level. (Idealday 24 and 18HE)
2 in 1 air purifier and dehumidifier. The two functions can be used also indipendently. (Idealday 14)
54DHS18
Large-capacity tank positioned on the front of the product for easy removal.
The dehumidifier stops automatically when the tank is full.
Version available with heater (800W) to speed up humidity absorption, giving
you a pleasant sensation of warmth. (Idealday 18HE).
54DHS18HE
54DHS24
Silent and light with integrated wheels.
2 speed turbo ventilator to quickly activate the set value.
ACCESSORIES
Connect up to the continuous flow condensation waste pipe if required.
All models use refrigerant without CFC/H-CFC to avoid ozone depleting.
54DHS18
54DHS18HE
54DHS24
ZO
N E D EP
R RIE R
TIO N
R-134a
CA
64
LE
ZERO O
54DHS11
54DHS14
54DHS 9000: set of three replacement carbon
filters
65
54DHS - DEHUMIDIFIERS
ROOM AIR CONDITIONERS
54DHS Dehumidifiers
Carrier model n°
54DHS014
54DHS018
54DHS018HE
lt
11
14
18
18
24
Power consumption a 27°C, 60% RH
W
205
232
410
410
410
1
2
2
2
2
m3/h
100
110
160
160
180
lt
7
Fan speeds
ROOM AIR CONDITIONERS 54DHS
Air flow
Tank capacity
54DHS024
6
6
7
7
Deodorizing filters
–
Yes
–
–
–
Antibacterial filters
–
–
Yes
Yes
Yes
Electric heater
–
–
–
Yes
–
Continuos drain hose connection
W
Yes
Yes
Yes
Yes
Yes
Container full light and auto shut off
Yes
Yes
Yes
Yes
Yes
Defrost
Yes
Yes
Yes
Yes
Yes
Electronic humidistat
Yes
Yes
Yes
Yes
Yes
Digital control
–
–
–
Yes
Yes
Castors
Yes
Yes
Yes
Yes
Yes
Transporting handle
Yes
Yes
Yes
Yes
Yes
°C
5-35
5-35
5-35
5-35
5-35
R134A
R134A
R134A
R134A
R134A
Size (W x H x D)
mm
325x540x355
325x540x355
345x722x352
345x722x352
345x722x352
Weight
kg
15
15,5
19,5
19,5
22
Working limits
Refrigerant
°C
The new “Comfort dehumidifyng” function
selects automatically the right level of humidity in relative to temperature variations.
(Idealday 24)
54DHS ROOM AIR CONDITIONERS
54DHS011
Capacity
*tested by EU directive CEE 73/23/CE
54DHS - DEHUMIDIFIERS
Idealday is the name, as these units offer the ideal solution for excess
humidity removal from your environment, preserving walls, furniture and
your health.
FEATURES
WHY IS IT SO IMPORTANT TO CONTROL THE HUMIDITY LEVEL?
Too much humidity damages your health and the furniture in the house. It harms people,
aggravating conditions like asthma, arthritis and rheumatism. High humidity levels cause
mould on the walls and damps patches, and spool surfaces. Humidity should be controlled
all year long, especially in rainy autumns and in humid summers.
CONTROLS
54DHS11
54DHS14
Special antibacterial filter to prevent growth of bacteria and form of mould for
purer and healthier environments. (Idealday 24 and 18HE)
Electronic control with multifunctional liquid crystal display with clock and timer
function for a precise regulation of the humidity level. (Idealday 24 and 18HE)
2 in 1 air purifier and dehumidifier. The two functions can be used also indipendently. (Idealday 14)
54DHS18
Large-capacity tank positioned on the front of the product for easy removal.
The dehumidifier stops automatically when the tank is full.
Version available with heater (800W) to speed up humidity absorption, giving
you a pleasant sensation of warmth. (Idealday 18HE).
54DHS18HE
54DHS24
Silent and light with integrated wheels.
2 speed turbo ventilator to quickly activate the set value.
ACCESSORIES
Connect up to the continuous flow condensation waste pipe if required.
All models use refrigerant without CFC/H-CFC to avoid ozone depleting.
54DHS18
54DHS18HE
54DHS24
ZO
N E D EP
R RIE R
TIO N
R-134a
CA
64
LE
ZERO O
54DHS11
54DHS14
54DHS 9000: set of three replacement carbon
filters
65

Similar documents