Contents - Wagtech Projects Ltd
Transcription
Contents - Wagtech Projects Ltd
Contents Section Pages Water Quality Testing 1 to 54 Hydrology & Groundwater 55 to 66 Soil / Sediment Sampling & Analysis 67 to 84 Meteorology 85 to 98 Toxic Gas Detection 99 to 104 Air / Dust Sampling & Monitoring 105 to 110 Air Quality Monitoring 111 to 120 Noise & Vibration Monitoring 121 to 124 Laboratory Analytical Equipment 125 to 131 Mobile Laboratories 132 to 138 Training 139 Water Quality Testing Water quality is the physical, chemical and micro biological characteristics of water. It is a measure of the condition of water relative to the requirements of one or more biotic species and any human need or purpose. It is most frequently used by reference to a set of standards which are used to assess water quality relative to the health of ecosystems, safety of human contact and drinking water. Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 1 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-102 Portable testing laboratory designed to assess the suitability of drinking water on-site, even in remote areas. Potalab® 1 is a portable microbiological and physico-chemical testing laboratory. It provides bacteriological testing using the accepted method of membrane filtration and incubation of faecal and total coliforms as an indicator of the presence of other harmful bacteria and viruses. The physico-chemical instruments are used in combination to quickly examine a supply to determine if a more detailed microbiological examination is required. All equipment is easily packed within the aluminium case for complete portability. Potalab 1 measures the following parameters; Faecal & Total Coliforms, pH, Conductivity, Turbidity, Chlorine, Nitrates, Nitrites, Ammonia, Fluorides and Arsenic EN15-104 Meteorology • For combined microbiological, physico-chemical testing in the lab or field • Wide range of physico-chemical parameters can be measured using highly accurate digital instruments • More cost effective than central laboratory testing • Simple technique - dual incubator allows analysis of both faecal & total coliforms simultaneously • Results incubated in just 14 hours • Completely portable - even runs off solar power • Uses low cost, long-life consumables, and equipment is easily sterilised in the field • Supplied with reagents for Ammonia, Arsenic, Chlorine, Fluorides, Nitrites and Nitrates as standard. Other parameters are listed on page 5. • Conforms to WHO Guidelines Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Advanced Water Testing Laboratory Toxic Gas Detection Air / Dust Sampling & Monitoring Potalab® 2 provides the same equipment and facilities as Potalab® 1, but without the physico-chemical instrumentation. The purpose of this unit is for microbiological testing only. Air Quality Monitoring EN15-102 Noise & Vibration Monitoring Laboratory Analytical Equipment Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 2 Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing Potalab® continued... Bacteriological Testing: The bacteriological filtration unit is supplied with a pistol grip vacuum pump, sampling cup and line, alongside 200 pads, gridded membranes and 38.1g membrane lauryl sulphate broth. Digital Dual Incubator: Microbiological testing is carried out using twin incubators for simultaneous incubation of Faecal and Total Coliforms if required. The temperature is digitally controlled and preset to 37oC and 44oC with an accuracy of ±0.1oC. Meteorology • Holds 2 racks of 25 petri-dishes allowing for up to 50 test’s at any one time • Features digital automatic timer facility for logging the incubation period in case of power failure • Fully portable can be powered by mains, internal battery, vehicle battery (cigarette lighter lead supplied) and solar power Temperature Range, °C 20 to 50 with preset levels at 37 or 44, automatic timer Display Clear digital LCD, 0.1oC resolution Capacity 2 x 25 aluminium dishes, 2 x 8 plastic / glass dishes Accuracy, oC ±0.1 Mains Power (AC) 220-240V, 50Hz, 110V, 60Hz, Battery Power (DC) Integral 12V re-chargeable battery through lead with crocodile clips and vehicle cigarette lighter socket plug Dimensions, mm 200 x 180 x 220 Weight, Kg 6 Purchase Specifications EN15-114 Portable Photometer Potalab® 1 comprises the following components: Twin incubator with digital temperature display and automatic timer facility. 50 re-usable aluminium petri dishes. (inc: petri dish rack). Electrical leads for AC110 / 220V operation, DC operation via vehicle cigarette lighter and crocodile leads along with separate re-chargeable battery (external to incubator, but internal to carrying case). Membrane filtration unit including collection flask, sampling cup, land line plus bronze disk, gaskets, O-rings, and pistol grip vacuum pump. 200 pads and membranes with pad dispenser, 38.1g membrane lauryl sulphate broth for 200 tests, 5 unique media measuring devices (mmd) for measuring precise amounts of lauryl sulphate broth (i.e, 10 tests only). Tweezers, 5 dropping pipettes, 4 autoclavable plastic bottles, hand lens, lighter, pen, clippers, screwdriver and a tube of lubrication grease. Conductivity / TDS Meter, pH / Temp / mV meter and a digital turbidity meter. Portable Photometer with reagents for chlorine, nitrates, nitrites, ammonia and fluorides. Digital Arsenator inc: filters, tablets and filter holders, sufficient for 200 Arsenic tests. Catalogue No Model Description EN15-102 Potalab 1 Portable water testing laboratory for microbiological and physico-chemical testing (weight 20Kg) EN15-104 Potalab® 2 For microbiological testing only (weight 18Kg) ® Accessories EN15-430 Membrane Filtration Kit EN15-432 Pad Dispenser EN15-434 Aluminuim Petri Dishes, Pack of 25 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Specification 3 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-162 The following instruments are supplied as standard in the Potalab® 1 to enable the measurement of specific parameters for this analysis: Turbidity Meter | pH / temp / mV Meter | Conductivity / TDS Meter Digital Arsenator | Portable Photometer Turbidity Meter Specification Range 0 to 1000 NTU Resolution 0.01, 0.1, 1 NTU (dependant on measurement & range) Accuracy ±2% / ±3% of reading Calibration Push button at 0.02, 20.0, 100 & 800 NTU Dimensions, mm / Weight, g 68(W) x 155(L) x 46(H) / 200 Power 4 x AAA Batteries Catalogue No EN16-162 EN16-111 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Physico-Chemical Analysis Meteorology Supplied with calibration kit pH / °C / mV Meter Specification Toxic Gas Detection 0.01 & ±0.01 pH mV Range ±199.9 mV & ±1999 mV (Extended) Resolution & Accuracy 0.1 mV & ±0.2 mV (within ±199.9 mV); 1 mV & ±2 mV (beyond ±199.9 mV) Temperature Range -10 to 110 °C Resolution & Accuracy 0.1 °C & ±0.5 °C No. of Calibration Points Up to 5 points Temperature Compensation Automatic / Manual (0 to 100 °C) Power 4 ‘AAA’ x 1.4V batteries or 9VDC power adaptor Supplied with electrodes and buffer solutions. Catalogue No EN16-111 EN16-136 Conductivity / TDS / °C Hand Held Meter Specification TDS Temperature 0 to 19.99, 20 to199.9, 200 to1999 µS/cm; 2.00 to 19.99, 20.0 to 199.9 mS/cm 0 to 9.9, 10 to 99.9, 100 to 999 ppm; 1.00 to 9.99, 10.0 to 99.9ppt -10ºC to 110ºC Resolution 0.01, 0.1, 1µS; 0.01, 0.1mS 0.01, 0.1, 1ppm; 0.01, 0.1ppt 0.1°C Accuracy ±0.2, 2, 20µS/cm; ±0.2,2mS/cm ±0.1, 1, 10ppm; ±0.1, 1ppt ±0.5oC Calibration up to 5 points (1 per range) 0.40 to 1.00 — TDS Factor 4 x 1.4V batteries or 9VDC power adaptor Supplied with calibration standards. Catalogue No EN16-136 EN15-502 Digital Arsenator Specification 2-100 ppb Timing Facility Up to 40 minutes Display LCD digital Power PP3 9v Battery (included) Resolution 0.001au Catalogue No EN15-502 Telephone: +44 (0)1635 872 929 Training Range Mobile Laboratories Power Laboratory Analytical Equipment Conductivity Range Noise & Vibration Monitoring Measurement Air Quality Monitoring -2.00 to 16.00 Resolution & Accuracy Air / Dust Sampling & Monitoring pH Range www.wagtechprojects.com [email protected] 4 Soil/ Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing Potalab® continued... EN15-114 Portable Photometer The Potalab Photometer offers a precise modern means of water analysis using an advanced solid-state digital readout colorimeter. The Photometer is fully integrated with water analysis systems. It offers a great value instrumental analysis for an extensive range of water tests. The Photometer accurately assesses the colour formed in the test sample and displays the readings directly in concentration units on its large LCD screen - no more inaccurate results due to variation in operator eyesight or lighting conditions. Direct reading colorimeter with automatic set up Operating wavelengths 450nm 500nm 550nm 575nm 600nm 650nm Meteorology Display Large Backlit graphic LCD screen Accuracy ± 0.5% at 4% transmittance Resolution 0.001au User selectable options Display language (French, German, Spanish, English, Italian) Test units Test cells Automatic adjustment for round test tubes from 12-20mm diameter Power Battery power (3 x AA) Dimensions (WxDxH), mm 146 x 275 x 75 Instrument rating Waterproof (IP67) Catalogue No Description EN15-114 Portable Photometer Air/ Dust Sampling & Monitoring Instrument Type Toxic Gas Detection Specification Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Reagents for use with Photometer Test Range mg/I Catalogue No Test Range mg/I Catalogue No Alkalinity, total (Alkaphot) 0 — 500 EN15-116 Hydrogen Peroxide HR 0 — 100 EN15-154 Alkalinity M (Alkaphot M) 0 — 500 EN15-118 Iron LR 0 — 1.0 EN15-156 Alkalinity P (Alkaphot P) 0 — 500 EN15-120 Iron HR 0 — 10 EN15-158 Aluminium 0 — 0.5 EN15-122 Magnesium (Magnecol) 0 — 100 EN15-160 Ammonia 0 — 1.0 (n) EN15-124 Manganese 0 — 0.03 EN15-162 Boron 0 — 2.5 EN15-126 Molybdate LR 0 — 15 EN15-164 Bromine 0 — 6.0 EN15-128 Molybdate HR 0 — 100 EN15-166 Calcium Hardness (Calcicol) 0 — 0.5 (n) EN15-130 Nitrate (nitratest) 0 — 20 (n) EN15-168 Chloride 0 — 5.0 EN15-132 Nitrite (nitricol) 0 — 0.5 (n) EN15-170 Chlorine DPD 1 0 — 5.0 EN15-134 Nitrite (nitriphot) 0 — 1500 EN15-172 Chlorine DPD 2 (Free, Mono & Di chloroamine) 0 — 5.0 EN15-136 Organophosphate 0 — 20 EN15-174 Chlorine DPD 3 (Free, Combined & Total) 0 — 5.0 EN15-138 Ozone 0 — 2.0 EN15-176 pH (Phenol Red) 6.8 — 8.4 EN15-178 Chlorine DPD 4 0 — 5.0 EN15-139 Phenol 0 — 5.0 EN15-180 EN15-140 Phosphate LR 0 — 4.0 EN15-182 EN15-142 Phosphate HR 0 — 100 EN15-184 Potassium 0 — 12 EN15-186 Silica 0 — 4.0 EN15-188 Sulphate 0 — 200 EN15-190 EN15-150 Sulphide 0 — 0.5 EN15-192 EN15-152 Sulphite (Sulphitest) 0 — 500 EN15-194 Zinc 0 — 4.0 EN15-196 Chlorine HR Chromism (Chromical) * Training 0 — 5.0 Copper (Coppercol) 0 — 5.0 EN15-144 Cyanuric Acid 0 — 200 EN15-146 Fluoride 0 — 1.5 EN15-148 Hardness (Hardicol) Hydrogen Peroxide LR 5 0 — 250 0 — 500 0 — 2.0 * * * * Packs of 250 * Packs of 200 Full Set of Reagents www.wagtechprojects.com [email protected] EN15-198 Telephone: +44 (0)1635 872 929 Water Quality Testing Portable testing laboratory designed to assess the suitability of drinking water on-site, even in remote areas. Capable of carrying out all the same tests as the Potalab, however the Potakit features less sophisticated instrumentation which in many cases makes the Potakit a more attractive and cost-effective choice. Potakit ® 1 is a low-cost, fully portable microbiological and physico-chemical testing kit designed to measure the key parameters of drinking water quality in the field. The instruments in the Potakit use simple techniques with low cost consumables to enable those with a non-technical background and minimum training to obtain accurate test results. Air / Dust Sampling & Monitoring Air Quality Monitoring Potakit® 2 provides the same equipment and facilities as Potakit® 1, but without the physico-chemical instrumentation. The purpose of this unit is for microbiological testing only. Toxic Gas Detection • Single incubator, capacity of 20 petri dishes, temperature switchable between 37 and 44ºC, allows incubation of either faecal or total coliforms • Fully portable Incubator - can be powered via external rechargeable battery, AC mains operation, DC operation via vehicle lighter socket or even solar power • Waterproof, digital pocket meters for pH and Conductivity • Two part turbidity tube • Colour Comparator for testing over 30 different chemical parameters • Includes the VCDK arsenic testing device for the visual, quantitative analysis of arsenic to ppb levels • Uses, long-life, low-cost reagents and consumables available locally through Wagtech Projects in-country representatives • Supplied with reagents & consumables to carry out 200 microbiological tests and 200 tests each of Ammonia, Arsenic, Chlorine (DPD1 & 3), Fluoride, Nitrites and Nitrates • Comprehensive but simple to use operation manuals for all instruments • All components housed in a single, lockable, water-proof aluminium carry case Meteorology Potakit® 1 measures the following parameters Faecal and Total Coliforms, pH, Conductivity, Turbidity, Chlorine, Nitrates Nitrites, Ammonia, Fluorides and Arsenic. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Basic Water Testing Laboratory Noise & Vibration Monitoring EN15-202 Laboratory Analytical Equipment Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 6 Potakit® continued... Microbiological Analysis Potakit® 1& 2: The Potakit® Incubator This small single portable incubator will allow a complete and accurate bacteriological analysis to be carried out in the field, for the analysis of faecal and total coliforms (switchable between 37oC & 44oC). • A total of 20 tests can be carried out at one time • Petri Dishes held in aluminium racks for easy loading • Totally portable — can run off mains, vehicle (cigarette lighter lead supplied) and solar power Specification Temperature setting Switchable between 37oC and 44oC Capacity 20 Petri dishes Accuracy, oC ±0.2 Mains power (AC) 220-240V, 50Hz, 110V, 60Hz, Battery power (DC) Integral 12V re-chargeable battery through lead with crocodile clips and vehicle cigarette lighter socket plug Dimensions, mm 155 x 230 x 200 Weight, Kg 3.3 Purchase Specifications Potakit® 1 comprises the following components: A single incubator, switchable between 37oC & 44oC, spirit thermometer, 20 re-usable aluminium petri dishes. Power supply to incubator is via an integral 220 / 110V AC mains adaptor / battery charger, electrical lead for 12V DC operation via vehicle dash board cigarette lighter, and crocodile lead for use with re-chargeable battery. Membrane filtration unit inc: (same specifications as supplied in Potalab except hand pump is rubber vacuum type) Pocket conductivity meter, pH meter, a 2 part turbidity tube, a colour comparator with colour discs and reagents for 200 tests of Chlorine, Nitrates, Ammonia, Nitrites and Fluorides; and the Visual Arsenic Kit (VCDK). All of which is supplied in a robust aluminium case. Catalogue No Model Description EN15-202 Potakit 1 Portable water testing laboratory for microbiological and physico-chemical testing (weight 10Kg) EN15-204 Potakit® 2 For microbiological testing only (weight 9Kg) ® Accessories EN15-430 Membrane Filtration Kit EN15-432 Pad Dispenser EN15-434 Aluminuim Petri Dishes, Pack of 25 Note: For accessories, consumables and spares for Water Test Kits - See page 12. Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 7 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing The following instruments are supplied as standard in the Potakit® 1 to enable the measurement of specific parameters for this analysis: pH Meter | Conductivity Meter | Arsenic Detection kit (VCDK) | Turbidity Tube | Colour Comparator pH / °C Waterproof, Pocket Meter EN16-102 Specification Range -1.0 to 15.0 pH 0.01 pH Accuracy, C ± 0.5°C Accuracy 3 pt (4.0, 7.0 or 10.0) Calibration 3 pt (4.0, 7.0 or 10.0) ATC Yes Electrode Type Double junction Battery Life > 500 hrs EN16-102 Waterproof pH Meter o Meteorology Resolution EN16-129 Specification 0.1µs/cm, 1µs, 0.01µs/cm Accuracy, oC ± 1% of full scale ATC Yes Temperature Display 0 To 50°C or 32 To 122°F Temperature Calibration Yes Battery Life > 150 hrs EN16-129 Waterproof Conductivity Meter EN15-1510 Noise & Vibration Monitoring Visual Arsenic Detection Kit (VCDK) This kit features a unique tri-filter arsenic trap which removes excess arsine gas as well as any hydrogen sulphide which also may be given off as a by-product of the reaction. Description EN15-510 Visual Arsenic Detection Kit (VCDK) EN15-512 2 Part acrylic tube, graduated 5 to 500 JTUs. Uses extinction method. Catalogue No Description EN15-206 Turbidity Tube Mobile Laboratories Turbidity Tube Laboratory Analytical Equipment •Colour Chart (readings up to 10-500 ppb) •Sufficient filters tablets & filter holders to conduct up to 200 tests. Catalogue No Air Quality Monitoring Resolution Air / Dust Sampling & Monitoring To 200 Toxic Gas Detection Conductivity, Waterproof Pocket Meter Multi Range Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Physio-Chemical Analysis Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 8 Potakit® continued... Colour Comparator Kit EN15-214 The colour comparator is quick and easy to use and gives accurate reliable results. The kit is used in conjunction with tablet reagents and colour charts to test 32 different parameters. Just add a tablet reagent to the test sample, place the tube in the comparator and match the colour against the appropriate colour disc. The kit includes: comparator, 4 square cuvettes and dilution tube. The kit contains no reagents or discs these should be ordered separately. Catalogue No Description EN15-214 Colour Comparator kit Comparator Reagents, Pack 250 Tests Colour Discs Catalogue No Test Range, mg/l Catalogue No Test Range, mg/l EN15-216 Alkalinity (Alkavis) 0 — 250 0 — 250 EN15-278 Alkalinity (Alkavis) 0 — 250 0 — 250 EN15-218 Aluminium 0 — 0.5 0 — 0.5 EN15-280 Aluminium 0 — 0.5 0 — 0.5 EN15-220 Ammonia 0 — 1.0 0 — 1.0 (N) EN15-282 Ammonia 0 — 1.0 0 — 1.0 (N) EN15-222 Bromine 0 — 2.0 0 — 2.0 EN15-284 Bromine 0 — 2.0 0 — 2.0 EN15-224 Bromine 0 — 8.0 0 — 8.0 EN15-286 Bromine 0 — 8.0 0 — 8.0 EN15-226 Chlorine DPD 0 — 5.0 0 — 5.0 EN15-288 Chlorine DPD 0 — 5.0 0 — 5.0 Chlorine DPD (Mono & Di Chloramine) 0 — 5.0 EN15-228 Chlorine DPD (Mono & Di Chloramine) 0 — 5.0 EN15-290 EN15-230 Chlorine DPD (combined & total) 0 — 5.0 EN15-292 Chlorine DPD (combined & total) 0 — 5.0 EN15-232 Chlorine DPD (total) 0 — 50 EN15-294 Chlorine DPD (total) 0 — 50 EN15-234 Chlorine HR 0 — 50 EN15-296 Chlorine HR 0 — 250 EN15-236 Chlorine HR 0 — 250 EN15-298 Copper (Coppercol) 0 — 5.0 EN15-238 Copper (Coppercol) 0 — 5.0 EN15-300 Fluoride 0 — 1.5 EN15-240 Fluoride 0 — 1.5 EN15-302 Hydrazine Powder 0 — 0.5 EN15-242 Hydrogen Peroxide LR 0 — 2.0 EN15-304 Hydrogen Peroxide LR 0 — 2.0 EN15-244 Hydrogen Peroxide HR 0 — 100 EN15-306 Hydrogen Peroxide HR 0 — 100 EN15-246 Iron MR & LR 0—5 EN15-308 Iron LR 0 — 1.0 EN15-248 Manganese 0 — 0.03 EN15-310 Iron MR 0 — 10 EN15-250 Molybdate HR 0 — 100 EN15-312 Manganese 0 — 0.03 EN15-252 Nitrate (Nitratest) 0 — 20 (N) EN15-314 Molybdate HR 0 — 100 EN15-254 Nitrite (Nitricol) 0 — 0.5 (N) EN15-316 Nitrate (Nitratest) 0 — 20 (N) EN15-256 Ozone 0 — 2.0 EN15-318 Nitrite (Nitricol) 0 — 0.5 (N) EN15-258 pH value (Bromocresol Purple) 5.2 — 6.8 EN15-320 Ozone 0 — 2.0 EN15-260 pH value (Bromothymol Blue) 6.0 — 8.4 EN15-322 pH value (Bromocresol Purple) 5.2 — 6.8 EN15-262 pH value (Phenol Red) 6.8 — 8.4 EN15-324 pH value (Bromothymol Blue) 6.0 — 8.4 EN15-264 pH value (Thymol Blue) 8.0 — 9.6 EN15-326 pH value (Phenol Red) 6.8 — 8.4 EN15-266 pH value (Universal pH) 4.0 — 11.0 EN15-328 pH value (Thymol Blue) 8.0 — 9.6 EN15-268 Phosphate LR 0 — 4.0 EN15-330 pH value (Universal pH) 4.0 — 11.0 EN15-270 Phosphate HR 0 — 100 EN15-332 Phosphate LR 0 — 4.0 EN15-272 Silica 0 — 4.0 EN15-334 Phosphate HR 0 — 100 EN15-274 Sulphide 0 — 0.5 EN15-336 Silica 0 — 4.0 EN15-276 Zinc 0 — 4.0 EN15-338 Sulphide 0 — 0.5 EN15-340 Zinc 0 — 4.0 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 9 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-114 Catalogue No Description EN15-400 CP1000 Portable Physico-Chemical Test Kit Accessories for Physico-Chemical Test Kit Public health testing reagent starter pack, comprising of full set of reagents (page 5) EN15-402 Groundwater testing reagent starter pack, cosisting of reagent for; Arsenic (page 14), Calcium Hardness (calcicol), chloride, chlorine (free, combined & Total), copper, fluoride, hardness (hardicol), iron LR, Iron HR, Magnesium (magnecol), Manganese, Nitrate (Nitratest), Nitrite ( Nitricol), Phosphate HR, Silica, Sulphate and Zinc (page 5). Supplied with Wag-Sack for ease of transport and storage. EN15-502 EN15-400 Noise & Vibration Monitoring Description EN15-198 EN16-136 Air Quality Monitoring Catalogue No EN16-111 Air / Dust Sampling & Monitoring components: • Conductivity Calibration Kit • Turbidity Standard • Plastic bottles, autoclavable 60ml • Aluminium carrying case • Training procedure manual • Full operating instructions • Water quality report sheets • Digital Arsenator Toxic Gas Detection This Kit comprises of the following • Portable Photometer • Round test tubes (pack of 5) • Test tube rack • Conductivity / TDS meter • pH / temp / mV meter • Portable turbidity meter • Calibration screwdrivers • pH calibration kit EN16-162 Meteorology This kit has been specifically designed for testing a wide range of physical & chemical water quality parameters. The kit contains a carefully selected range of high quality digital instruments that makes it ideally suited for field based drilling engineers and groundwater testing applications. The kit is based around the Portable Photometer. It is capable of the analysis of over 40 different chemical parameters. It is fully portable, waterproof, and features pre-programmed test methods and touch screen operation. It provides instant and highly accurate results. pH and Conductivity / TDS are measured using separate, waterproof, hand-held meters. Turbidity is measured using a waterproof, hand-held digital meter. It is accurate in the range 0-1000NTU. Also includes the Digital Arsenator — the worlds only digital field instrument for the determination of arsenic in water down to ppb levels. Supplied with all the necessary calibration consumables & solutions, dilution tube, full operating instructions and water quality report sheets. All components are housed in a waterproof, lightweight carry case for easy handling and storage. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Physico-Chemical Test Kit Laboratory Analytical Equipment Mobile Laboratories EN15-402 Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 10 EN15-403 Portable Microbiological Water Testing Laboratory The Potaflex® portable microbiological laboratory has been designed in conjunction with ICRC and is an ideal resource for testing microbiological parameters in the field. The unique Flexi Rack System provides the user with a wide range of media options to suit their preferences and ensures the maximum amount of tests can be performed at any one time. • Fully portable - specially designed for field use • Extremely versatile - can test for a variety of bacteria, including: Pseudomonas, Faecal Streptococci, Coliforms. (Faecal and Total Coliforms) • Flexi media options - wide range of pre-prepared dip slides and nutri disks can be tested • Meets WHO & EU guidelines • Pre-prepared dip slides are simply dipped into the water sample, inserted into the unit and then placed into the incubator The Flexi Rack System (FRS) This is a unique device that allows the analysis of different microbiological parameters using different methods and materials simply choose between re-usable aluminium petri dishes, pre-prepared nutri disks, pre-prepared dip slides or a combination of each. The unit can accommodate either 20 disposable nutri disks, up to 40 re-usable aluminium petri dishes or up to 10 dip slides. Membrane Filtration System A membrane filtration unit is supplied as standard with the Potaflex® System. Easily sterilised and consists of: • A collection flask • Sample cup • Bronze disk • Gaskets & O rings • Land line • Pistol grip vacuum pump EN15-403 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 11 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing Specification Temperature range 20oC to 50oC variable Display LCD clear digital Capacity 40 Aluminium petri dishes, 20 nutri disks, 10 dip slides Accuracy ±0.1oC Mains power (AC) 12V DC Power supply to incubator is via an integral 230V AC mains adaptor, plus electrical lead for 12V DC operation via vehicle cigarette lighter. Dimensions, mm Internal: 130 x 150 x 110 External: 200 x 250 x 180 Weight, Kg 4 Model Description EN15-403 Potaflex® Portable Water Microbiological Laboratory. (weight 10Kg) Accessories, Consumables & Spares for Water Test Kits Catalogue No Description Air / Dust Sampling & Monitoring Catalogue No Toxic Gas Detection Potaflex® comprises the following components: 2 litre incubator, with digital temperature display. Flexible Rack System (FRS), 20 aluminium petri dishes, 5x Media Measuring Device (MMD), 200 pads, membranes and 38.1g membrane lauryl sulphate broth. AC mains lead and vehicle battery cigarette lighter lead. Membrane filtration unit includes: collection flask, sampling cup, 2m land line plus bronze disk, gaskets, O-rings, and pistol grip vacuum pump. Tweezers, 5 dropping pipettes, 4 plastic bottles, hand lens, lighter, pen, clippers, screwdriver and a tube of lubrication grease. All of which is housed in a rugged lockable aluminium flight case. Meteorology Purchase Specification Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Potaflex® Incubator System: The incubator unit is located within a sturdy carrying case and has a temperature range of +20oC to 50oC. Typically temperatures are set at 37oC for total coliforms and 44oC for faecal coliforms and faecal streptococci. However the flexible range can be set at other temperatures such as 42oC for pseudomonas. Accessories EN15-406 Portable Steam Steriliser, Capacity 24 litres, non electric EN15-408 Portable Steam Steriliser, Capacity 39 litres, non electric EN15-410 Glassware & Consumables pack consisting of flasks, beakers, burettes, sampling bottles, pipettes, measuring cylinders, water deioniser, top pan balance, portable 14L steriliser, and miscellaneous laboratory accessories. Consumables EN15-414 Cetrimide nutri disks for the detection of Pseudomonas Aeruginosa in water and foodstuffs. (pack of 100) EN15-416 M-FC nutri disks for the detection of E.Coli and faecal coliforms in water and foodstuffs. (pack of 100) EN15-418 Plate count nutri disks for the determination of colony counts in water, milk and food. (pack of 100) EN15-420 Coliform starter pack comprising grid membranes, pads and growth medium. (for 200 tests) EN15-422 Lauryl Sulphate Broth tub of 38.1g (for 200 tests) EN15-424 Absorbent pads and membranes (for 200 tests) EN15-426 Pre-prepared dip slides, sterilised gridded dip slides, impregnated with coliform media.(pack of 25) EN15-428 Faecal Streptococci Starter Pack Spares Membrane Filtration Kit EN15-432 Pad Dispenser EN15-434 Aluminuim Petri Dishes, Pack of 25 EN15-438 Sterile Plastic Petri Dishes, Pack of 200 Telephone: +44 (0)1635 872 929 Training EN15-430 Mobile Laboratories Azide nutri disks for the detection of faecal streptocci in water and foodstuffs. (pack of 100) Laboratory Analytical Equipment EN15-412 Noise & Vibration Monitoring Portable Steam Steriliser, Capacity 14 litres, non electric Air Quality Monitoring EN15-404 www.wagtechprojects.com [email protected] 12 EN15-502 Arsenator®, Digital Portable Arsenic Testing The Arsenator® system is the lowest cost, most portable and accurate method for determining Arsenic in safe limits (WHO guide-lines 10 ppb/µgl). Carefully designed to be simple and safe to use either in the lab or in the field. The complete system comes with sufficient reagents and consumables for over 400 tests. • Low cost digital arsenic testing device • Fully portable, designed specially for field use • Immediate results in the field in less than 20 minutes • Simple, safe and easy to operate • Gives accurate test results between the critical range of 2µgl (ppb) to 100µgl (ppb) • Designed in conjunction with Prof. Walter Kosmus and laboratory tested by Imperial College London • Field tested in conjunction with UNICEF / WHO WAT / SAN monitoring programmes • Environmentally friendly Specification Range 2-100 µgl/ppb Timing facility up to 40 minutes Resolution 0.001 AU Power PP3 9V Battery Digital Arsenator Kit comprises the following components: • Portable Digital Arsenator® System • Tri-Filter Arsenic gas trap • 5 x Arsenic collection filter holders (Black) • 5 x Arsine gas removal filter holders (Red) • 10 x Hydrogen Sulphide removal filters • 420 x Reagent A1 (dry powder sachet) • 420 x Tablet A2 • 420 x Arsenic collection filters • 420 x Arsine gas removal filters • Colour comparison chart (<10 to 500ppb) • Dilution tube • Spare battery • Waste disposal bags • Gloves and tweezers • Rugged carry case with Instruction manual Catalogue No Description EN15-502 Digital Arsenator. Supplied with Reagents and Consumables for 420 tests Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 13 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-506 A mobile workstation consisting of 5 complete sets of Arsenic generators, allowing for up to 5 tests to be conducted simultaneously. All of which is supplied in a custom built carrying case that also provides a stable working area. To be used in conjunction with the Arsenator® Catalogue No Description EN15-506 Multi Pack Accessory kit for Arsenator® Visual Arsenic Detection Kit (VCDK) Meteorology A low cost, fully portable arsenic detection pack, which allows for the quantative, visual analysis of arsenic in drinking water from less than 10 µg/l (ppb) up to 500 µg/l (ppb). The kit features a unique tri-filter arsenic trap which removes excess arsine gas as well as any Hydrogen Sulphide which may also be given off as a by-product of the reaction. Both reagents are added to the water sample in the flask and the colour chart is then visually compared to get a reading. Toxic Gas Detection • Ideal for quick mass screening • Low cost per test • Simple and easy to operate • Environmentally friendly • Safe handling — no chemical liquids • Housed in a robust custom built carry case Visual Arsenic Detection Kit (VCDK) comprises the following components: Description EN15-510 Visual Detection Kit. Air Quality Monitoring Catalogue No EN15-510 Air / Dust Sampling & Monitoring • 1x Unique tri-filter arsenic trap and a 125ml graduated flask • 4x Arsenic collection filter holders (Black) • 4x Arsine gas removal filter holders (Red) • 4x Hydrogen sulphide filters • Colour comparison chart (<10 to 500ppb) • Gloves, tweezers and bags • Sufficient tablets, reagents and filters to perform 200 tests Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Multi-Pack Accessory Kit for Arsenator® Refill Pack Description EN15-504 Refill pack contains sufficient filter holders and tablets for 200 tests for all Arsenator products Please contact us for additional spares & consumables for Water Test kits. Laboratory Analytical Equipment Note: Noise & Vibration Monitoring Catalogue No Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 14 Testing for Heavy Metals in Water Contamination of our water resources by toxic heavy metals is increasingly becoming a problem the world over. Widespread industrial and urban pollution is responsible for these heavy metals in the environment. The products in this section have been designed specifically to allow easier, cost-effective monitoring of the heavy metals most commonly associated with health and environmental problems. Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 15 www.trace2o.com The Metalyser Range has been designed specifically to allow easier, cost-effective monitoring of heavy metals most commonly associated with public health and environmental problems. Developed and manufactured solely in the UK, the Metalyser Range offers a breakthrough in terms of simple-to-use field and laboratory instruments that offers high levels of accuracy at significantly lower cost to other alternatives such as ICP-MS and Atomic Absorption. Analysis of heavy metals in water has traditionally been difficult in the field. By combining the proven method of Anodic Stripping Voltammetry (ASV) along with an innovative sonde design and a simple buffer delivery system, Trace2o has developed instruments that can finally deliver reproducible results in the field as well as the laboratory. The design of the Metalyser allows for the addition of future parameters, without the need to upgrade the instrument. The Metalyser is available in 5 versions: Metalyser HM1000 – Simple-to-use, rapid field analysis of 10 heavy metals in water. Metalyser Deluxe HM2000 – Simple-to-use, rapid field analysis of heavy metals using both electrochemical and photometric techniques. Metalyser Field Pro HM3000 – Simple-to-use, rapid field analysis of heavy metals in water but incorporating a tablet PC for detailed graphical analysis by more experienced users. Metalyser HM4000 Heavy Metals Soils Analyser - for testing a range of heavy metals in soils – see page 79. Metalyser Benchtop HM5000 - a laboratory based version which enables the electrochemist to develop his own voltammetric methods using bespoke Metaware software for analysis. www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Metalyser HM1000 EN15-600 The HM1000 is an entry level heavy metals analyser aimed at the novice field user. Results can be obtained quickly and easily for several of the most common heavy metals onsite using the portable hand held unit. The instrument and sensor head (sonde) is fully waterproof as well as the rugged carry case enabling testing in all weathers and includes all the consumables and accessories required to carry out 50 tests. Meteorology • Field based detection of heavy metals in water to low ppb concentrations providing data at site • Rapid results allowing immediate action on remediation • No complicated sample preparation or analysis procedures in the field allowing non-technical personnel the ability to obtain lab-comparable results • Step-by-step pictorial guides allowing non-experienced personnel the ability to use instrument quickly and easily without reading in-depth manuals • Low cost per test • No PC required for sample analysis • Rugged and durable instrumentation built for tough environments allowing operation even in adverse weather conditions Measures the following 10 parameters Data Results obtained in 5 minutes Internal memory: 1000 data sets with facility to enter sample number, time and date Transfer via USB to PC New application methods can be uploaded to the unit via USB User Interface LCD full graphics backlit display: 128 x 128 pix Joystick cursor control Menu driven software Power Rechargeable battery providing in excess of 50 tests per charge Alternative power supply via mains adaptor or vehicle cigarette lighter Kit Dimensions: 470mm (L) x 370mm (W) x 170mm (D) Net Weight: 9kg Air Quality Monitoring Analytical principle: Anodic & Cathodic stripping voltammetry using disc working electrodes. Parameters measured: Arsenic (III), Total Arsenic, Cadmium, Chromium, Copper, Lead, Manganese, Mercury, Nickel & Zinc Operating Temperature: -20°C to +70°C Air / Dust Sampling & Monitoring Operation Lower Limit (ppb) Upper Limit (ppb) WHO Guideline Value (ppb) 5 500 <10 Total Arsenic As (Total) 10 500 <10 Cadmium Cd 3 500 <3 Chromium Cr 50 500 <50 Copper Cu 5 500 <2000 Lead Pb 5 500 <10 Manganese Mn 5 200 <100 Mercury Hg 5 500 <6 *Nickel Ni 50 500 <70 Zinc Zn 5 500 <4000 Catalogue No Description EN15-600 HM1000 - Metalyser - Complete with Sonde assembly electrodes, consumable kit and buffers and standards for 50 tests. Supplied in a hard-shell carry case Sonde Training Note: For Metalyser consumables - see page 18 Telephone: +44 (0)1635 872 929 Mobile Laboratories As (III) Laboratory Analytical Equipment Arsenic (III) Noise & Vibration Monitoring Limits of Detection (Fresh Water) Parameter Toxic Gas Detection Metalyser Specification www.wagtechprojects.com [email protected] 16 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 17 EN15-620 Metalyser Deluxe HM2000 Portable field kit combining electrochemical and photometric techniques for analysing a wider range of metals in water • Rapid in-field analysis • Suitable for remediation studies • Voltammetric and photometric techniques • Precise results from ppb to ppm levels • Intuitive user interface • Rugged, waterproof kit • Consumables for 50 tests included Measures the following parameters Catalogue No Description EN15-620 HM2000 – Deluxe Metalyser - Complete with Sonde assembly, electrodes, consumable kit, buffers and standards for 50 tests and photometer. Supplied in a hard-shell carry case Metalyser Field Pro HM3000 The Field Pro is an advanced portable analyser with an integrated ruggedised tablet PC and bespoke Metaware software to enable detailed graphical analysis by more experienced users. The Field Pro is housed in a fully waterproof case, and with the water-resistant tough PC and waterproof instrument, testing can continue in the most adverse of conditions. The integrated tablet PC provides instant graphical data, via the dedicated pre-loaded Metaware software. The user can now take traditional laboratory analysis tools such as repeat scanning and multi-point standard additions to the field, greatly increasing confidence in the results as well as providing much more information about the sample matrix and potential interferences. With the manual peak height calculation function, peaks can be measured that automatic techniques cannot detect. The spreadsheet function can average data, calculate correlation coefficients, draw best fit lines and calculate the original sample concentration. With these tools the field user can detect levels as low as 1ppb with confidence. • Field based detection of heavy metals to low ppb concentrations using the popular Metalyser instrument but with a tablet PC offering advanced levels of analysis • Rapid results allowing immediate remedial action to be taken • Integrated tablet PC incorporating Metaware software, displays and stores all of the graphical data, allowing the more advanced user to undertake enhanced analysis at site • Data manipulation using the tablet PC allows for extended detection limits and high levels of accuracy • Rugged and durable PC and instrumentation built for a tough environment which enable operation even in adverse weather conditions Measures the following parameters Catalogue No Description EN15-640 HM3000 - Metalyser Field Pro- Complete with integral tablet PC, Sonde assembly, electrodes, consumable kit and buffers and standards for 50 tests. Supplied in 2 hard-shell carry cases. www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing A compact benchtop laboratory based voltammetry instrument for use by scientists and technicians engaged in education, research, and industry. Laboratory-based analysis of heavy metals has traditionally been complex and expensive, requiring dedicated installations and experienced operators. With no costly installation expenses and an easy-to-use interface, the HM5000 is the instrument of choice for novice to advanced users, offering a realistic and economic alternative to AAS and ICP-MS. The instrument has been designed with several features to overcome the traditional challenges found in voltammetric analysis. The innovative nitrogen sample purge diminishes interference from oxygen, whilst the automatic elevation platform reduces sample disturbance, improving repeatability. Our bespoke Metaware software offers the experienced analyst full control over electrochemical methods. The software allows the user to change time and voltage variables, as well as offering a range of stripping techniques, i.e. square wave, differential pulse, linear sweep and cyclic voltammetry. Peak height, base line subtraction, standard addition, calibration curve, linear regression / spreadsheet calculation User Interface Power Full PC control via USB and Bluetooth Metaware benchtop graphical control software 12-15V DC (Optional battery back-up) Weight / Dims 3.5Kg, 200 x 370 x 210mm Measuring Range ppm to <1ppb levels. Dependent on sample type, preparation and operating settings Fresh water, sea water, river water, waste water, sewer water, portable water, factory effluent, food, beverages, textiles, plastics, biological and other measurable samples. Sample types may require digestion, extraction, dilution and/or pre-treatment Sample Types The following method files are pre-loaded in the software HM5000 - Metalyser Benchtop - Instrument supplied complete with power supply, PC Software, USB Cable, sample cups and pre-loaded method files. (PC, buffers, standards and conditioning solutions ordered separately) Consumables for all Metalysers Catalogue No Description 200 tests EN15-602 M1, M4, & M5, Buffer and Standards Pack (Cd, Pb, Cu, Zn) EN15-603 EN15-604 M2, Buffer and Standards Pack (Hg) EN15-605 EN15-606 M3, Buffer and Standards Pack (As) EN15-607 EN15-608 M6, Buffer and Standards Pack (Mn) EN15-609 EN15-610 M7, Buffer and Standards Pack (Cr) EN15-611 EN15-612 M8, Buffer and Standards Pack (Ni) Telephone: +44 (0)1635 872 929 Training 50 tests EN15-601 Mobile Laboratories Description EN15-660 Laboratory Analytical Equipment Catalogue No Noise & Vibration Monitoring Data Evaluation Air Quality Monitoring Analytical principle: Anodic & Cathodic stripping voltammetry using disc working electrodes Measuring techniques: Square wave, different pulse, linear sweep, cyclic voltammetry Operating Temperature: 0 to +70°C Air / Dust Sampling & Monitoring Operation Toxic Gas Detection Specification Meteorology • Laboratory based analysis of heavy metals in solution from ppm to low ppb levels • Complete control over voltammetric parameters allowing advanced users to customise their analysis and the ability to develop their own methods • Minimal set-up costs with no expensive gas lines, extraction or temperature- controlled environment needed, unlike AAS or ICP-MS • Starter kit of method files included for easy analysis by users of any ability • Method file compatibility with HM1000 means user developed parameters can be adapted for in-field use • Increased ability to handle differing sample matrices • Bluetooth connectivity also enables the user to remotely control the instrument away from possible spills and hazardous chemicals. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Metalyser Benchtop HM5000 www.wagtechprojects.com [email protected] 18 ENVIROKIT Environmental Health Inspectors Kit EN15-690 This kit has been especially designed with the Environmental Health Inspector in mind and it includes a range of instruments which will help him quickly to carry out on-the-spot tests and also, where necessary, to take samples away to the lab for later analysis. The ENVIROKIT contains the following components: (for details of each instrument please refer to the product numbers shown) Water Quality • Pocket pH meter. Page 37 (EN16-102) • Pocket Conductivity meter. Page 40 (EN16-129) • Turbidity Tubes, 2 part. Page 8 (EN15-206) • Water Level Dipmeter. Page 62 (EN26-136) • Tube Water Sampler (capacity 250ml). Page 65 (EN26-160) • Water Sample Bottles (5) • Re-sealable polythene bags, pack of 25 EN16-102 Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing Noise • Mini Digital Sound Level Meter, a simple meter for monitoring noise levels within a neighbourhood. Page 122 (EN81-102) Air Quality Monitoring Radiation • Portable Radon Monitor, for measuring levels of this naturally occurring but dangerous gas in the home, office and factory. Page 120 (EN73-506) EN73-506 Catalogue No Description EN15-690 Environmental Health Inspectors Kit Supplied complete packed into a rugged backpack for easy transport in the field. EN81-102 EN44-292 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring EN16-129 Indoor Air Quality • Multi-Function Environment Meter measures indoor Sound Levels, Light Levels, relative Humidity and Temperature. Page 98 (EN44-292) • General Dust Sampling & Monitoring Kit. Page 107 (EN65-210 & EN65-212) • Portable Ambient Carbon Monoxide Monitor, measures the concentration of this harmful gas produced by faulty heating and cooking appliances. Page 102 (EN55-260) • Gas Leak Detector, for rapid checks on gas pipe connections. Page 102 (EN55-262) 19 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-700 Biological Oxygen Demand is the amount of oxygen used by micro-organisms when they bio-degrade organic material in a water sample. It is used as an important measure of the degree of contamination in a supply. This allows exact and error free readings of the BOD value to be read directly in mg/L or to be calculated by single multiplication. The system is supplied complete with 6 of the following: dark glass 500ml bottles, PVC caps, capillary caps, KOH containers, interchangeable scales, mercury (2ml bottles), 35 mm magnetic stirrer bars and an operation manual. Description EN15-700 Standard 6 bottle BOD System EN15-702 Standard 6 bottle Spares Kit Laboratory Analytical Equipment Catalogue No Noise & Vibration Monitoring • Simple handling • Direct reading of BOD in mg/L • Maintenance free, integral • Programmable stirrer Air Quality Monitoring The conventional BOD system comprises 6 bottles and 6 mercury capillary tubes with a constant scale of up to 1000mg/L. Air / Dust Sampling & Monitoring Standard BOD System Toxic Gas Detection Biological Oxygen Demand (BOD) Meteorology Laboratory tests to determine waste water quality indicators are used to assess the suitability of waste water for disposal or re-use. Tests measure physical, chemical, and biological characteristics of the waste water and this section includes some of the key specialist equipment required. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Waste Water Testing & Toxicity Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 20 Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing BOD Merc-Free Analysis Sensor Innovative electronic pressure measuring system for BOD determinations using manometric technique. • Micro-processor controlled • Mercury Free • Ergonomic sensor design for simple use, reading and data retrieval • Inductive stirring mechanism How the Merc-Free system works… The Merc-Free instrument is pushed over the BOD bottle having first placed two NaOH tablets into the special bung. The reaction of the tablets with the air vapour causes an increase in pressure which is measured by the instrument and converted into mg/l on the display. Merc-Free Sensor System 6 and 10 EN15-710 BOD Sensor System 6, a complete package for 6 tests, consisting of a 6-position stirring station with BOD Sensors, dark glass bottles, alkali holders and stirring bars. BOD Sensor System 6 (wireless), a complete package for 6 tests as above but includes a wireless system for instant PC download of the BOD values. BOD Sensor System 10, a complete package for 10 tests, consisting of a 10-position stirring station with BOD Sensors, dark glass bottles, alkali holders and stirring bars. Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Specification Measurement Principle Laboratory Analytical Equipment Wireless Sensor System Electronic pressure probe Electronic protection IP54 Display digits 3 LED Power Supply 2 x lithium batteries Safety class 3IEC 1010 Bottle capacity 500ml Power 115v or 230vAC, 50-60Hz Weight, kg 2.3 Dimensions (cm) (W x H x D) 35 x 30 x 15 27 x 19 x 30 Performance Memorised Data 5 BOD values at 24hr intervals Reading value BOD Values Every 30mins / 2 / 4 / 6 / 8 / 12 / 24hrs Every 2 / 4 / 6 / 8 / 12 / 24hrs for longer analysis mg/I(ppm) directly on the display Directly on the display at anytime also after the standard 5 days period BOD last determination Automatically transferred to wireless databox and displayed by software Possible Catalogue No Description EN15-706 BOD Sensor System 6 (Standard) EN15-708 BOD Sensor System 10 (Standard) EN15-710 BOD Sensor System 6 (Wireless) includes wireless databox, software & cable EN15-712 BOD Control Tablets (pkt of 8) Training Mobile Laboratories Standard Sensor System 21 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-724 Two sizes of BOD incubators are available for 1 or 2 BOD systems. All models are suitable for use with the standard or Merc-Free systems. Air circulation within the incubators ensures an even temperature throughout Controllable 90L Incubator with RS232 Controllable 90L Incubator with RS232 Controllable 220L incubator with RS232 Controllable 220L Incubator with RS232 20˚C ±0.5 3 to 50˚C 3 to 50˚C 3 to 50˚C 3 to 50˚C Temperature Homogeneity ±0.5˚C (air) ±0.5˚C (air) ±0.5˚C (air) ±0.5˚C (air) Stability ±0.5˚C (air) ±0.5˚C (air) ±0.5˚C (air) ±0.5˚C (air) 0.1˚C 0.1˚C 0.1˚C 0.1˚C 220-240v, 50-60Hz 220-240v, 50-60Hz 220-240v, 50-60Hz 220-240v, 50-60Hz Temperature Settings Temperature Resolution Power Supply 220-240v, 50-60Hz Meteorology Dedicated 90L BOD Incubator Glass Door Dedicated 90L BOD Incubator EN15-720 Controllable 90L Incubator with RS232 EN15-722 Controllable 90L Incubator with RS232 & glass door EN15-724 Controllable 220L Incubator with RS232 EN15-726 Controllable 220L Incubator with RS232 & glass door Please refer to our General Lab Catalogue for a wide range of glassware and other equipment required for Water Quality Analysis. Noise & Vibration Monitoring Note: Air Quality Monitoring Description EN15-718 EN15-722 Air / Dust Sampling & Monitoring Catalogue No Toxic Gas Detection 90 Litre BOD Incubators The three small dimension refrigerating incubators have been built purposely for the incubation of manometric BOD measurement units; allowing 1, 6 or 10 bottle system to be incubated. 220 Litre BOD Incubators The two complete and advanced incubators are intended for any use which requires precise and constant temperature. The continuous internal air circulation and the thermostating microprocessor controlled Auto-Tuning system allows a uniform temperature within the internal chamber. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis BOD Incubators Laboratory Analytical Equipment Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 22 COD System Chemical Oxygen Demand (COD) is a vital test for assessing the quality of water. The COD predicts the oxygen requirement of the water and is used for the monitoring and control of discharges and for assessing treatment plant performance. The COD System offers a method which is both practical and convenient. The reagents are supplied pre-mixed and pre-dispensed into borosillicate glass test tubes. The test is simply carried out by adding 2ml of sample to the tube, closing the cap and then digesting for two hours at 150°C. The tubes are then cooled and the sample is measured using a photometer. • Carries out tests quickly and effectively • Offered in four ranges from 5mg/L to 20,000mg/L • Allows 24 tubes to be digested at the same time • Reagents comply and meet international standard methods and requirements Supplied complete with: • COD Dry-block heater • Safety screen • Test tube rack • Portable Photometer • Adaptor • Thermometer • Micropipettor An optional rugged carrying case is available should the system need to be taken to remote areas. Catalogue No Description EN15-728 COD System 220 / 240V 50-Hz EN15-730 COD System 110 / 120V 50-Hz EN15-732 Rugged carrying case Catalogue No COD Tube Reagent Tests (24 pack) EN15-734 5-150mg/L range EN15-736 20-400mg/L range EN15-738 50-2000mg/L range EN15-740 500-20,000mg/L range EN15-728 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 23 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing The Kjeldahl method is named after the Danish chemist who developed it more than a century ago. Today, the method is widely used according to official methods to determine nitrogen and proteins in food, feed, soil, waste water etc. The equipment in this section enables the Kjeldahl method to be performed easily and with reproducible results in order to determine the Total Kjeldahl Nitrogen (TKN) content in waste water samples. Digestion Units EN15-750 Meteorology Toxic Gas Detection These are widely used instruments within laboratories performing analysis for different applications such as digestions in the Kjeldahl process for protein determination and analysis in the environmental field. A user-friendly program menu allows for the selection of up to 20 work programs, while 4 temperature ramps are available for the simultaneous digestion of 6, or 20 samples in test tubes of different dimensions. These instruments are provided with a wide range of options (temperature selections, programmable permanence time, continuous working mode availability etc) and with a visualisation display which allows for the desired values to be set and to monitor the digestion progress. Number of samples EN15-750 EN15-752 6 in 250ml tubes with 42mm Ø 20 in 250ml tubes with 42mm Ø Temperature range, °C EN15-752 From room temperature to 450 Epoxy painted stainless steel structure Selectable programs 20 with 4 ramps for each programs Selectable durations from 1 to 999 minutes Power supply 230V / 50-60Hz 1100 Weight, kg 10 24 293 x 152 x 339 393 x 152 x 446 Suction cap EN15-758 EN15-764 Support system EN15-760 EN15-766 Glassware handle with heat shields EN15-756 EN15-762 Dimensions (WxHxD), mm 2300 Operating Accessories Laboratory Analytical Equipment Test tubes, Ø 42x300mm, 250ml, 3 pcs / box, for use with both units Noise & Vibration Monitoring Power, W Air Quality Monitoring Construction material Air / Dust Sampling & Monitoring • High accuracy - temperature precision is ±0.5%, with a heating speed of 20 to 420°C in 30 minutes • RS232 interface - for PC data transfer and storage according to GLP • Safety - Electronic microprocessor checks and automatically calibrates the heating block’s temperature • Customisable - the operator can choose among 6 different languages Catalogue No Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis KJeldahl-Determination Of Total Kjeldahl Nitrogen (TKN) EN15-754 EN15-750 Mobile Laboratories EN15-768 EN15-770 Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 24 EN15-768 Recirculating Water Pump for Fumes Aspiration Recirculating water pump that lets two different timed modes for the digesters to be selected. This ensures optimum aspiration depending on the digestion phases and the number of samples in the digester connected to the pump. Lack of adequate water mains pressure or its high consumption frequently prevent common water pumps from being used. This unit consists of a tank where the water introduced is recirculated continuously, offering considerable savings on water. The type and quality of the materials used make the instrument extremely quiet and long-lasting, and guarantee a high flow rate (up to 35 l/min). Combined with the scrubber unit, it provides the ideal complement to achieve highly effective fume neutralization that is developed during acid digestions. The unit is supplied complete with a Viton tube, 10 x 14mm diameter • Automatism and optimization of the sucking power • Strongly reduced water consumption in comparison to water jet pumps connected to tap • Possibility of avoiding emission into the atmosphere of gaseous pollutants or polluted waters into drainages • Independent from tap water contingencies like low water availability or low pressure Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing EN15-770 Air / Dust Sampling & Monitoring Toxic Gas Detection Specification Air Quality Monitoring Training 35 Flow regulation, l/min: from 0 to 35 Residual pressure with water temp. of 15°C: 35 mmhg Power: 160 W Power supply: 230 V / 50 Hz Weight, kg: 8.4 Dimensions (wxhxd), mm: 250 x 400 x 370 Catalogue No Description EN15-768 Recirculating water pump for Flumes Aspiration Scrubber A scrubber, that when connected to the Recirculating Water Pump, is designed to neutralise corrosive and toxic fumes that develop during oxidative mineralizations or other processes. The system is supplied in the configuration consisting of two stages; condensation, and neutralisation. The instrument can be supplied with a third (optional) stage, generally used with samples that generate high amounts of fumes during digestion (e.g. soybean). The unit has a broad range of applications, from the Kjeldahl method to neutralisation with acids and bases. Thanks to the elevated surface of contact between gas and liquid, the unit provides effective cleaning of the fumes, preventing their hazardous emission into the laboratory and the environment. Noise & Vibration Monitoring Laboratory Analytical Equipment Mobile Laboratories 25 Air flow max, l/min: EN15-750 • A highly efficient neutralization, due to the optimized gas-liquid contact • Safe and practical to use • Simple disposal of condensates • Simple control and replacement of neutralizing solution EN15-768 Specification EN15-770 Construction material: Epoxy painted stainless steel structure Weight, kg: 3.5 Dimensions (WxHxD), mm: 300 x 500 x 190 Catalogue No Description EN15-770 Scrubber EN15-772 Filter for activated carbon EN15-774 Refill activated carbon pack of 10 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-776 Distillation units that are designed for diversified and flexible use, including applications such as determining ammoniacal nitrogen, protein nitrogen, (Kjeldahl or direct alkaline distillation), nitric nitrogen (after reduction), phenols, volatile fatty acids, cyanides, alcohol content, etc, according to official procedures. The units come with a patented steam generator that assures distillations are carried out in absolute safety and without routine maintenance. The supply water feed is automatically stopped during pauses, thus cutting down on its consumption. The instrument is equipped with a system that recognises when the sliding protection door is not closed and when the test tube is not in position, without which the dosing pump does not start operation. Use of an innovative system allows various sizes of test tubes to be used and 500 ml Kjeldahl flasks to be housed. Both units work in accordance with official methods AOAC, EPA, DIN e ISO, with model EN15-776 representing the basic unit, and model EN15-778 the more advanced, semi-automatic unit. EN15-778 Catalogue No EN15-776 Analysis time of 100ml of distillate: 5 minutes 4 minutes 0 to 99 minutes 0 to 30 minutes Time related to start for Devada alloy analysis: Steam generator: EN15-778 Toxic Gas Detection • A maintenance-free steam generator that uses deionised water • Innovative titanium condenser that achieves outstanding heat exchange and higher resistance than glass, and that is also easy to clean • Technopolymer splash head (alkali-resistant) that ensures a longer lifetime Meteorology Supplied complete with 42mm Dia x 300mm - 250ml test tube, flask, tongs and inlet tube. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Distillation Units Deionised / Distilled water Manual Automatic Reproducibility (RSD): <1% Recovery: > 99.5 % at nitrogen levels 1 - 200 mgN Detection limit: > 0.1 mgN Sodium hydroxide addition: Automatic Manual Automatic Boric acid addition: Manual Sodium hydroxide addition: Automatic Dilution water volume: - 0 to 200 ml Boric acid volume: - 0 to 100 ml - 0 to 100 % Steam flow regulation: 0.5 l/min at 15°C - 1 l/min at 30°C Weight, kg: Dimensions, mm: 25 26 385 x 780 x 416 385 x 780 x 416 Power: 240V AC 50HZ Description EN15-754 Test tubes, Ø 42 x 300mm, 250ml, 3 pcs / box EN15-782 Test tubes, Ø 26 x 300mm, 100ml, 6 pcs / box EN15-784 Test tube, Ø 48 x 260mm, 300ml EN15-786 Spacer for test tube Ø 48 x 260mm EN15-788 Test tube, Ø 80 x 300mm for alcohol determination EN15-790 Test tube connection Ø 26mm, Ø 48mm, 500ml balloon Mobile Laboratories Catalogue No Laboratory Analytical Equipment Accessories Noise & Vibration Monitoring Tap water consumption: Air Quality Monitoring Dilution water addition: Air / Dust Sampling & Monitoring Distillation residual removal: Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 26 Flocculators Jar Test The type of chemical coagulant to be adopted for removing suspended solids from wastewater and the dosage required are established based on laboratory results obtained from the so called Jar Test. EN15-800 Toxic Gas Detection Specification Air / Dust Sampling & Monitoring Air Quality Monitoring Noise & Vibration Monitoring Laboratory Analytical Equipment Training Mobile Laboratories 27 Portable Flocculators The Portable Flocculator was developed for optimum use in the field. It runs on 100-240V mains power supply or using 12 DC by connecting it to a normal battery or a car cigarette lighter. The Flocculator 4-position features a non-slip base that ensures the stability of the beakers during operation. It is particularly suitable for carrying out Jar Tests for optimizing the dosing of coagulants and polyelectrolyte in the proximity of water treatment plants. Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing EN15-808 Number of stirring rods 4 Construction material Epoxy painted metal structure Speed selector Multi-selector (settable speed for each rod) Speed settings 5 speeds: 20, 40, 50, 100, 200rpm) Speed resolution ±2rpm Display Analogue Power 6W Power supply 100-240V / 50-60Hz Weight, kg 4.8 Dimension (WxHxD) mm 250 x 320 x 250 Catalogue No Description EN15-800 Portable Flocculator EN15-802 Carrying Case EN15-804 Glass Beaker 1000ml EN15-806 Plastic Beaker 1000ml Flocculators For flocculation (jar) tests on water and effluent samples. It is specially designed for repeatable conditions between samples and from run to run. A digital display clearly indicates the speed of the rotational stainless steel paddles, which can be varied from 10 to 300rpm. The digital timer can be set to count down from 1 to 99 minutes or 1 to 99 hours. • Accepts six samples • Digital indication of speed and time • Two pre-set programs • Built in illumination for easy viewing of samples Specification 4 Place System 6 Place System 645 x 347 x 260 935 x 347 x 260 Weight, kg 13 17 Power, W 11 19 Dimensions, mm Catalogue No Description EN15-808 4 position Flocculator set speed digital display EN15-810 6 position Flocculator se speed digital display EN15-804 Glass Beaker 1000ml EN15-806 Plastic Beaker 1000ml www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-830 • Transparent cone, made from tough styrene acrylonitrile • With moulded graduations. Lower part is graduated to 2ml x 0.1, 10ml x 0.5, 40ml x 1, 100ml x 2 and 1000ml x 50 Catalogue No Description EN15-830 Imhoff sedimentation cone, plastic, 1000ml Imhoff Sedimentation Cone, Glass • For determining the amount of sediment in sewage or industrial waste • Graduated up to 40ml and with capacity mark at 1000ml • Manufactured from borosilicate glass Description EN15-832 Imhoff sedimentation cone, glass, 1000ml Imhoff Cone Stands EN15-832 EN15-836 • Acrylic stands for mounting Imhoff Cones • All stands have a locating recess in the base Description EN15-834 Cylindrical stand for 1 cone EN15-836 Rectangular stand for 2 cones EN15-838 Rectangular stand for 3 cones Toxic Gas Detection Catalogue No Meteorology Catalogue No Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Imhoff Sedimentation Cone, Plastic Air / Dust Sampling & Monitoring Sewage Effluent Test Kit Sewage Eflluents are used in many countries for irrigation, and this kit provides a simple means of checking the quality of such water. Sewage Effluent Test kit EN15-842 Reagents for permanganate value and pH (50 tests) Mobile Laboratories Description EN15-840 Laboratory Analytical Equipment Catalogue No EN15-840 Noise & Vibration Monitoring •Permanganate Value - enables the Permanganate Value (PV) to be determined and the effluent classified as to its acceptability for discharge. •pH test - Chemical and biological reactions at sewage works are profoundly influenced by pH. A pH test will also check, for example, on the effect of acid or alkaline trade wastes in the effluent flow. •Turbidity and Suspended Solids - Designed to give a measure of the suspended solids content of the final effluent. It is also useful in following the day-to-day variation in the quality of sewage and effluent. •Probable BOD, COD and TOC - It is possible to derive an indication of the Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD) and Total Organic Carbon (TOC) from the result of the Permanganate Value test. •Temperature - A check should be maintained on the temperature of effluent discharges and these should always be close to ambient temperatures. •Kit comes complete with a -10° to +50° thermometer in a brass protecting case. Air Quality Monitoring It is used extensively for control testing at small sewage works. Based on simplified methods of sewage effluent testing, the kit contains tests for the essential quality control checks required for the day-to-day operation of sewage effluent treatment plants. Each of the tests is performed simply without the use of complicated equipment and are suitable without formal training in water testing and analysis. Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 28 Acid Mining Test Kit This chemical test kit has been formulated for the acid mining industry to measure discharge water which can be both acidic and alkaline, depending on the metal type. The discharge water can also contain metals such as iron. Since the run-off water will eventually find its way to lakes and rivers, it is important to test it to make sure it does not pollute the environment and water reservoirs. The Acid Mining Test Kit includes all the necessary tests for alkalinity, acidity, pH and iron. The reagent bottles are in easy-to-recognise ascending numbers, and allow your tests to be more expedient and less time consuming. The testing procedures are clearly shown in the step-by-step instruction manual so that anyone can carry out the analysis. pH measurements are made using a pocket electronic pH tester, for faster and more accurate results than conventional litmus paper. Catalogue No Description EN15-850 Acid Mining Test Kit (approx 100 tests) Cyanide Test Kit Cyanide is a pollutant that originates mostly from metallurgic, galvanic and other industrial processes, such as gold and silver extraction. Because it is poisonous to the human nervous system, it is imperative to monitor and control cyanide levels in portable water. When in contact with acids, cyanide is freed as a poisonous gas. The Environmental Protection Agency (EPA) has established that the maximum level of cyanide in water is not to exceed 0.2 mg/L (ppm). Specification Method Checker Disc Range 0.00-0.30 mg/L Smallest Increment 0.01 mg/L Chemical Method Pyride-pyrazolone Number of Tests 100 Weight, g 580 Catalogue No Description EN15-852 Cyanide Test Kit with sufficient reagents for 100 tests EN15-854 Cyanide Test Kit refill pack for 100 tests Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 29 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-856 Cyanide is a pollutant that originates mostly from metallurgical and galvanic industrial plants and is extremely poisonous to the human nervous system. It is therefore imperative to monitor and control its level in potable water. Continuous monitoring in waste effluents is required, and cyanide is removed using alkaline chlorination procedures. European standards limit the concentration of cyanide in drinking water to 0.05 mg/L, while the USEPA has established that the maximum level is not to exceed 0.2 mg/L. This instrument is an ideal replacement to test kits, and will provide fast and accurate measurements at the touch of a button. Reagents are supplied in individual sachets containing fast dissolve powder for ease of use. Specification 0.000 to 0.200 mg/L Resolution 0.001 mg/L Accuracy ±0.005 mg/L ±3% of reading Light Source LED 585 nm Light Life Life of the instrument Light Detection Silicon Photocell Battery Type / Life 1 x 9V / approx. 40 hours of continuous use; auto-off after 10 minutes of non use Meteorology Range Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Cyanide Meter Toxic Gas Detection 180 x 83 x 46 Weight, g 290 Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed. The reation between cyanide and reagents causes a blue tint in the sample Catalogue No Description EN15-856 Cyanide Meter supplied complete with cuvettes, battery and instructions but excluding reagents EN15-858 Cyanide reagents pack for use with Cyanide Meter. Pack of 100 EN15-859 Cyanide reagents pack for use with Cyanide Meter. Pack of 300 Air Quality Monitoring 0 to 50°C; RH max 95% non-condensing Air / Dust Sampling & Monitoring Environment Dimensions, mm Noise & Vibration Monitoring Laboratory Analytical Equipment Unable to find the equipment you need? Mobile Laboratories Please contact our in-house experts for advice Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 30 Air / Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing Toxicity EN15-860 Eclox - Water Purity Testing Kit Developed from a kit in use by the armed forces throughout the world. This Eclox test kit is now available for water and sanitation engineers to give a rapid indication of the toxicity levels present at the water source. The heart of the Eclox is a luminometer which gives a generic identification of the toxicity of a water sample. Applications: • The kit can provide a rapid indication of water quality (4 minutes). • On-site detection of contamination. • Pollution incident tracking. • Emergency Pollution Response Kit. • World wide field water evaluation. • Chemicals from urine, faeces, phenols, amines, heavy metals, cyanide and many other toxic substances are all rapidly detected. Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Features: 31 • Rapid detection of contaminated water. • Reliable indicator of relative water quality. • Sensitive to heavy metals and poisons. • Easy to use with minimum of training. • Robust, washable and totally portable. • Completely self contained. • Use in a wide range of environmental conditions. Specification Data Logging Up to 60 tests recorded in full detail Consumables Shelf Life 2yrs at ambient temperature Battery Life Greater than 250 tests Batteries 4 X AA Temperature -20˚C to +55˚C Weight, Kg 6.5 fully loaded Dimensions, mm 489 X 400 X 200 Catalogue No EN15-862 Description Eclox Toxicity Kit Supplied with luminometer, micropipettes, tips, sampling bottles, set of 7 chemiluminescence reagents and pesticide strips. Set of 7 chemiluminescence reagents. EN15-864 Pack of 25 pesticide strips. EN15-860 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Oil In Water EN15-868 • Measurement range from below 1ppm to over 1,000ppm without dilution • Unaffected by suspended solids • Performance independent of process temperature • Precision sample volume not required • No acid required Noise & Vibration Monitoring • No solvents required • Simple procedure • Complete analysis in less than 10 minutes • Measures WSO’s at pH < 2 • Accurate and highly repeatable • UV fluorescence technology • Disposable cuvettes • Measurements per battery change: >1,000 • Meets IP67, dust-proof, waterproof, non-metallic case Mobile Laboratories • Powered by 4 AAA batteries Description EN15-868 Hand Held Oil in Water Monitor Laboratory Analytical Equipment • Correlates to standard laboratory gravimetric and IR methods Catalogue No Air Quality Monitoring • Measures dispersed (free) oil independent of WSO (Water Soluble Organics) Air / Dust Sampling & Monitoring Features: Measures all oils including the heaviest of crudes to condensates up to 50° API and refined diesel range oil, lube oils, and heavy fuel oils in water Toxic Gas Detection This light, easy to use, accurate and low cost instrument is used for measuring crude oil and condensates in produced water, de-salter tail water, tank bottoms, cargo heaters, or anywhere that crude oil comes in contact with water. This monitor has been developed to a method that measures oil-in-water and uses no solvent. The advantages are significant in that we have eliminated the health and safety hazards of transporting, handling and disposing of solvents commonly used in the field for oil-in-water analysis. Along with safety, the method eliminates operator error associated with precision liquid measurements during the analysis process. It is a robust method with unprecedented accuracy and repeatability. Meteorology Hand Held Oil in Water Monitor Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 32 Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing EN15-870 Oil Content Monitor The Oil Content Monitor is an automated portable unit for monitoring oil content in both fresh water and saltwater. The one-touch monitoring process is fully automated, from sample extraction to analysis and sample expulsion. The unit utilizes an extraction solvent to ensure superior oil particle stability and infrared absorptiometry for sample analysis. Using 0mg/l -200mg/l dynamic ranging, the unit is capable of analyzing both high and low concentrations. A sperate dedicated solvent reclaimer can be purchased and will filter out extraction solvent. This uses no electricity and greatly reduces test costs. Specification Measurement principle Solvent extraction, NDIR analysis (Infrared spectroscopy) Measurement range 0mg/l ~ 200mg/l dynamic ranging Resolution Air/ Dust Sampling & Monitoring Air Quality Monitoring 100 to 200 mg/L; 1 mg/L 0 to 9.9 mg/L; ± 0.2 mg/L ± 1 digit Repeatability 10.0 to 99.9 mg/L; ± 2 mg/L ± 1 digit 100 to 200 mg/L; ± 4 mg/L ± 1 digit Measurement Manually controlled Calibration One touch calibration after the calibration standard is introduced to the instrument Extraction Solvent S-316 solvent Sample / Solvent Volume 20 mL, ratio of sample to solvent is 2:1 Extraction Method Built-in extractor for oily water samples Display Measured value; 3 digits LCD with backlight message; Character display LCD with back-light (16×2 characters) Functions Data memory up to 50 data, self diagnostics, stable type display, interactive operation, calendar clock Output RS-232C, parallel printer port Ambient Temperature 0 to 40ºC Power 100 to 120 V AC ±10%,50/60 Hz, 80 VA 200 to 240 V AC ±10%,50/60 Hz, 120 VA Dimensions, mm 200 × 315 × 342 Weight, kg 7 Catalogue No Description EN15-870 Oil Content Monitor EN15-872 Extraction Solvent EN15-874 Solvent Reclaimer Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring 0 to 99.9 mg/L; 0.1 mg/L 33 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-856 This Hydrocarbon Analyser is designed to measure ppm levels of petroleum hydrocarbons in water and also to meet field monitoring requirements. In the analytical mode, it gives fast and accurate quantitative data for petroleum hydrocarbons in water. The data correlates very well with laboratory gas chromatographic analysis. In the screening mode, it offers fast relative data on petroleum hydrocarbon contamination, tracking field gas chromatograph data for TPH, and responds strongly to BTEX components. The unit works equally well for ground water, surface water, waste water, and soil samples. Typical applications include Site assessment, Storm / waste water monitoring, Leak detection for buried fuel tanks, Well plume monitoring, Spill control & Remediation monitoring • Detects petroleum hydrocarbons directly in water Meteorology • Provides in-situ real time information Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Hydrocarbon Analyser • Pays for itself with lower analysis costs • Reduces sample collection • Logs data from 100 samples • Easy to calibrate • Serial output to laptop or printer Vapour Water 0-20,000 ppm as TPH 0-2,000 ppm as TPH Lower limit of detection <10 ppm as xylene 0.1 ppm as xylene Hydrocarbons detected c6 and higher MW petroleum hydrocarbons C6 and higher MW petroleum hydrocarbons Accuracy ±15% of reading ±10% of reading Response time (initial) <5 seconds <5 seconds <1 minute <5 minutes 0° - 50°C 0° - 50°C Trend correlation with GC data 95% 98% Display Backlit LCD Logging memory Data from 100 samples 8 hours normal operation Charge 12 hour charge period, AC or vehicle Dimensions (WxHxD) mm 250 x 300 x 180 Weight, kg 4.5 Cable length, m 30 Catalogue No Description EN15-878 Portable Hydrocarbon Analyser Catalogue No Description EN15-880 Soil Headspace Jar EN15-882 Pre-Mixed Calibration Standards (20ml). 25 ppm solution EN15-884 Pre-Mixed Calibration Standards (20ml). 50 ppm solution Mobile Laboratories Accessories Laboratory Analytical Equipment Supplied complete with sets of 2 calibration solution, charger, interface cable, and a professional air / water tight rugged carrying case. Noise & Vibration Monitoring Battery life Air Quality Monitoring Response time (to 95%) Operating temperature range Air / Dust Sampling & Monitoring Specification Operating range Toxic Gas Detection • Easy to use menu driven software Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 34 Oil / Water Interface Meter The Oil / Water Interface Probe is used to determine the thickness of hydrocarbon, in Light Non-Aqueous Phase (LNAPL) and Dense Non-Aqueous Phase (DNAPL) in groundwater, and to also detect the presence of water in storage tanks. It consists of a stainless steel shroud with a specially designed float and conductive meter to minimise surface tension errors, providing unparalleled accuracy. As the probe is lowered into the LNAPL, a single audible buzz is heard and a green light shows. Once the probe reached the water at the oil / water interface, a two-tone buzzer is heard and both the green and red lamps show. EN15-886 • Slim-line 20mm probe • High accuracy • Simple to use • Easy to clean • Robust construction • Compact design Specification Shroud diameter 20mm Shroud length 225mm Shroud materials Austenitic stainless steel Probe material Austenitic stainless steel Float diameter 10mm Float material Hydrocarbon resistant Audible indicator High dB(A) dual buzzers Power 9 V PP3 battery Catalogue No Description EN15-886 Oil / Water Interface Meter 30m EN15-888 Oil / Water Interface Meter 50m EN15-890 Oil / Water Interface Meter100m EN15-892 Oil / Water Interface Meterr 200m Delivering to over 90 countries Worldwide... Delivering direct to your door Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 35 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN15-894 This hand held digital density meter is the latest design in portable density measurement. Designed for use in the most demanding industrial environments, it provides the density, specific gravity or % concentration of your sample. Need to save the data for later analysis? Measured results are stored in the instruments memory – up to 1024 data points – and can easily be transferred to a computer and printed later. Two intrinsically safe versions are available, the casing of the basic version is plastic, and this has many advantages, however with plastics the main disadvantage is that not many are chemically resistant to both solvents and acids & alkalis. For this reason we have two intrinsically safe versions. Acid / Alkaline meter suitable for use in applications such as battery bank monitoring. Air / Dust Sampling & Monitoring Specification Repeatability 0.0005 g/cm3 Accuracy 0.001 g/cm3 Toxic Gas Detection Features: •Ease of Use - Small, compact, light weight design •No arm fatigue, even when measuring hundreds of samples daily •Easily fits into tight spaces •Designed so that display is easily seen, regardless of sampling position •True one hand operation •Pipette-style pump - Better control of sample flow •Less effort required •No bellows to crack or leak •Entire pump assembly easily replaced Meteorology Solvent / Petrochemical meter is suitable for applications such as checking fuel samples. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Digital Density Meter Not required Temperature Range 0 to 40 °C , filling at higher temperatures possible Minimum Sample Volume 2 mL Concentration Volume Integrated tables (H2SO4, Brix,% alcohol, API gravity) and custom functions Interfaces IrOBEX/IrLPT Weight, g 396 Description EN15-894 Portable Digital Density meter, Standard Version EN15-896 Portable Digital Density meter, Acid / Alkaline Resistant EN15-898 Portable Digital Density meter, Solvent / Petrochemical Resistant Laboratory Analytical Equipment Catalogue No Noise & Vibration Monitoring 0 to 3 g/cm3 Viscosity Correction Air Quality Monitoring Measuring Range Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 36 Digital Meters EN16-102 Air/ Dust Sampling & Monitoring Toxic Gas Detection Specification Air Quality Monitoring Noise & Vibration Monitoring Laboratory Analytical Equipment Training Mobile Laboratories Parameter pH Temperature Range -1.00 to 15.00 pH 0.0 to 50.0 ºC Resolution 0.01 pH 0.1ºC Accuracy ±0.01 pH ±0.5ºC Calibration Up to 3 points USA: 4.01, 7.0, 10.01 NIST: pH 4.01, 6.86, 9.18 ±5ºC in 1ºC increments Automatic temperature compensation (ATC) EN16-106 37 pH / oC Waterproof, Pocket Meter • Measures pH and Temperature, simple to use and waterproof • Large custom dual display and unique ribbed body for better grip • ±0.01 pH accuracy • Temperature (oC) readout is suitable for most ASTM and EPA test procedures • User replaceable double junction electrode - ideal for dirty water, heavy metals, sulfides, and organics • Auto-buffer recognition with choice of USA or NIST pH buffer standards • Push-button calibration, Self-diagnostic messages, HOLD function, Auto-off, and Automatic Temperature Compensation Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing - Yes Catalogue No Description EN16-102 pH / ºC, Waterproof, Pocket Meter EN16-104 Replacement sensor pH / oC / mV Hand Held Meter • Portable meter measuring pH, Temperature and mV • Very economical, low cost but high performance in pH accuracy and resolution • mV measurement mode is useful for ORP measurements • Multi-point calibration (up to 3 points) • Push-button calibration, self-diagnostic messages, Hold function • Auto-off feature • Supplied complete with pH electrode, carrying kit and calibration standards and temperature probe Specification Parameter pH Temperature Range 0.01 to 14.00 pH 0.0 to 100.0ºC mV or Rel mV ±1000 mV Resolution 0.01 pH 0.1ºC 1 mV Accuracy 0.01 pH ±0.5ºC ±2 mV Calibration Up to 3 points (min 2) ±5.0ºC (0.1ºC increments) ±50mV (0.1 mV increments) Catalogue No Description EN16-106 pH / oC / mV Hand Held Meter EN16-108 Replacement pH electrode, plastic body, gel filled EN16-110 Replacement temperature probe www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-111 • Handheld pH meter for measuring pH, mV and Temperature • Multi-point pH calibration (up to 6 Points) with pH buffer standards • Auto-buffer recognition with for hassle-free operation • Non-volatile memory stores and recalls up to 100 sets of pH and mV • Self-diagnostic messages • Ready indicator • Auto-off • RS232 output to PC with DAS software • Supplied complete with pH electrode, temperature probe, 2 electrode holders and carrying case Specification pH mV or Rel mV Temperature Range -2.00 to 16.00pH ± 1999 mV (Extended) -10 to 110ºC Resolution 0.01 pH 0.1 mV (within ±199.9mV) 1mV (beyond ±199.9 mV) 0.1ºC Accuracy ±0.01 pH ±0.2 mV (within ±199.9mV) ±2mV (beyond ±199.9 mV) ±0.5ºC Calibration up to 5 points — Meteorology Parameter ±5.0ºC (0.1º increments) Description EN16-111 pH / oC / mV Hand Held Meter EN16-116 Replacement pH electrode, plastic body, gel filled EN16-110 Replacement temperature probe EN16-112 pH mV or Rel mV Temperature Range -2.00 to 16.00 pH ±2000 mV 0.0 to 100.0ºC Resolution 0.01 pH 0.1 mV (within ±199.9mV) 1 mV (beyond ±200 mV) 0.1ºC Accuracy ± 0.01 pH ±0.2 mV (within ±199.9mV) ±1 mV (beyond ±200 mV) ± 0.3ºC Calibration Up to 6 points ± 150 mV (1 mV increments) ± 5.0ºC (0.1º increments) Description EN16-112 pH / oC / mV Waterproof, Hand Held Meter EN16-116 Replacement pH electrode, plastic body, gel filled EN16-118 Replacement temperature probe Mobile Laboratories Catalogue No Laboratory Analytical Equipment Parameter Noise & Vibration Monitoring Specification Air Quality Monitoring • Compact and rugged waterproof meter for measuring pH, mV, Relative mV and Temperature • Non-volatile memory stores and recalls up to 50 sets of pH, mV or relative mV readings with temperature (oC / oF) • Real-time clock stamps stored data and calibration data with date / time • Multi-point pH calibration (up to 6 points) with Auto-buffer recognition for choice of USA, NIST, and DIN pH buffer standards • Advanced setup allows you to customise meter parameters where required • Self-diagnostic messages, ready indicator, auto-hold function, auto-off features • Supplied with double junction pH electrode, temperature probe and case Air / Dust Sampling & Monitoring pH / oC / mV Waterproof, Hand Held Meter Toxic Gas Detection Catalogue No Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis pH / oC / mV Advanced Hand Held Meter Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 38 EN16-114 Specification Training Parameter pH ORP Temperature Range -2.00 to 16.00 pH ± 2000 mV 0.0 to 100.0°C Rel. mV Range - ± 2000 mV - Resolution 0.01 pH 0.1 mV (±199.9mV) / 1mV (beyond) 0.1°C Accuracy ± 0.01 pH ±0.2 mV (±199.9mV) / ±2mV (beyond) ±0.3°C Compensation Calibration - - ATC / MTC (0 to 100°C) (pH only) up to 5 Offset in 0.1 °incements; offset range:±5.0°C Buffer Sets USA, NIST - Power Requirements Toxic Gas Detection Air/ Dust Sampling & Monitoring Air Quality Monitoring Noise & Vibration Monitoring Laboratory Analytical Equipment Mobile Laboratories 39 pH / oC / mV Bench Meter Economical, user-friendly and accurate, the pH 700 is your ideal choice for routine applications in laboratories, productions plants and schools. • Large, easy-to-read display • Ready indicator let you know when readings are stable • Up to 5-point calibration with auto-buffer recognition • Non-volatile memory holds up to 100 data points • Integral electrode holder Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing EN16-120 - - - Catalogue No Description EN16-114 pH / oC / mV Bench Meter EN16-108 Replacement pH electrode EN16-124 Replacement temperature probe 9 V DC adapter, 1.3 A (100 / 240 VAC, SMPS) Ion / pH / °C Bench Meter An intuitive, self-diagnostic and flexible instrument with advanced set-up options for user-customization. View pH, ION or Redox reading together with temperature, electrode status, calibration points, date and time all at once. • Up to 6-point push button calibration with auto-buffer recognition • Quick, easy electrode diagnosis with pH slope and offset display • Non-volatile memory holds up to 500 data points – time and date-stamped • Bi-directional RS232 for easy data transfer to computer • Cal-due alarm – no more out-dated calibrations • Auto-logging function for convenient continuous monitoring • Limit alarm alerts when reading falls out of range • Password protection for setup and calibration Specification Parameter Range pH -2.000 to 20.000 pH Rel. mV Range - ORP ION Temperature ±2000.0 mV 0.001 TO 19999 PPM (±2000 mV) 0.0 to 100.0°C ±2000.0 mV - Resolution 0.1 / 0.01 / 0.001 pH 0.1 mV 2 or 3 digits 0.1°C Accuracy ±0.002 pH + 1LSD ±0.2 mV 0.5% full scale (monovalent); 1% full scale (divalent) ±0.3°C Calibration Up to 6 preset or 5 custom Buffer Sets USA, NIST, DIN User 1, User 2, Custom Power Requirements 2 to 8 - - 9 V DC adapter, 1.3 A (100 / 240 VAC, SMPS) Catalogue No Description EN16-120 Ion pH/ °C Bench Meter EN16-122 Replacement ion / pH electrode EN16-124 Replacement temperature probe www.wagtechprojects.com [email protected] - - Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-126 The advanced Bench Meter offers easy, single-channel operation for pH and ORP measurements without compromising on performance or features. Meteorology • Auto-calibrates with up to five pH buffers from three standard sets and fifteen different buffers; also accepts custom buffers and manual calibration • Accepts standard BNC pH glass electrodes and DIN pH ISFET electrodes - no need for adapters • Wide pH and mV measurement range of -2.000 to 20.000 pH and ± 2000.0 mV • Advanced real-time on-screen graphing function provides useful indication for specific measurements such as titration. • Advanced USB, IRDA connectivity allows extensive host / device communication capabilities. • Ethernet / Internet-ready with RJ45 input for connection to LAN or Internet for quick research and data sharing. • Secure log-in for up to ten users •Complete with pH electrode, ATC probe, electrode holder, SMPS power adapter, RS232 cable & software Specification Model No Range pH Temp mV ±2000.0mV -5.0 to 105.0°C 0.1 / 0.01 / 0.001 0.1°C 0.1mV Accuracy ±0.1 / 0.01 / 0.002 0.2°C ±0.2mV Memory 100 Data sets Output USB, IrDA, RS232C Dimensions (WxDxH) cm Toxic Gas Detection -2.000 to +20.000 Resolution Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis pH / °C / mV Advanced Bench Meter 23.5 x 16.5 x 8.9 Description EN16-126 pH / oC / mV Advanced Bench Meter EN16-127 Replacement pH electrode EN16-128 Replacement temperature probe Air / Dust Sampling & Monitoring Catalogue No EN16-129 Laboratory Analytical Equipment Specification Noise & Vibration Monitoring • Measures conductivity and temperature in one simple, portable instrument • Cup-type sensor scoops or dips into samples for greater flexibility • Includes Push-button calibration • HOLD function • Auto-off • Self-diagnostic features • Waterproof, • Dustproof • Automatic Temperature Compensation Air Quality Monitoring Conductivity, Waterproof, Pocket Meter 0-200 µS/cm, 0-2000µS/cm, 0-20 mS/cm Resolution 0.1 µS/cm, 1µS/cm, 0.01mS/cm Accuracy ± 1% full scale Calibration 3 Auto / 3 Manual Temperature Display Range: -0oC to 50.0oC; Resolution: 0.1oC; Accuracy: ±0.5oC Temperature Calibration ±5.0oC (0.1oC increments) Catalogue No Description EN16-129 Conductivity, Waterproof Meter EN16-130 Replacement conductivity sensor Mobile Laboratories Range Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 40 EN16-132 lConductivity / TDS / oC Hand Held Meter • Hand held meter for measuring Conductivity and Temperature • Single point and multi-point automatic or manual calibration • User customisation of the following functions: - Normalisation temperature - Automatic / manual temperature compensation from 0ºC to 100ºC - User adjustable TDS factor - Cell constant and reset to factory settings • Hold and auto power-off functions • Easy to read high contrast display • Splash proof keypad designed for easy finger touch operation • Supplied with a rubber boot to protect the meter from accidental damage • The hinge at the back allows for easy benchtop viewing • Supplied with conductivity electrode with ATC and carrying kit set Specification Conductivity range 0 to 19.99, 20.0µS/cm, 199.9 µS/cm, 200 to 1999 µS/cm, 2.00 to 19.99 mS/cm, 20.0 to 199.9 mS/cm Resolution and accuracy 0.01, 0.1, 1 µS/cm; 0.01, 0.1 mS/cm & ±1% Full Scale No. of calibration points 5, maximum 1 per range Temperature range -10.0 to 110.0°C Resolution and accuracy 0.1°C & ±0.5°C Cell constant 0.1, 1.0, 10.0 (selectable) Temperature coefficient 0.0 to 3.0%/°C Normalisation temperature 20.0 & 25.0 ºC Catalogue No Description EN16-132 Conductivity / TDS / ºC Hand Held Meter EN16-134 Replacement conductivity electrode, ultem-body with ATC, BNC Note: For a wide range of meters and other laboratory equipment please see our General Lab Catalogue. Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 41 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-136 • Hand held meter for measuring Conductivity / TDS • Single and Multi-point automatic or manual calibration • Automatic / manual temperature compensation from 0 to 100oC • User adjustable TDS factor • Hold, power-off and self-diagnostic message functions • Rugged, splash-proof design • Supplied complete with carrying case, calibration standards, rinse bottle and conductivity electrode with ATC Specification Conductivity TDS Temperature Range 0 to 19.99, 20 to199.9, 200 to1999 µS/cm; 2.00 to 19.99, 20.0 to 199.9 mS/cm 0 to 9.9, 10 to 99.9, 100 to 999 ppm; 1.00 to 9.99, 10.0 to 99.9ppt -10ºC to 110ºC Resolution 0.01, 0.1, 1µS; 0.01, 0.1mS 0.01, 0.1, 1ppm; 0.01, 0.1ppt 0.1°C Accuracy ±0.2, 2, 20µS/cm; ±0.2,2mS/cm ±0.1, 1, 10ppm; ±0.1, 1ppt ±0.5oC Calibration up to 5 points (1 per range) 0.40 to 1.00 — TDS Factor Description EN16-136 Conductivity / TDS / ºC Hand Held Meter EN16-138 Replacement conductivity / TDS electrode, ultem-body with 6 pin connector EN16-140 Conductivity TDS Temperature Range 0 to 19.99, 199.9, 1999 µS/cm 2.0 to 19.99mS/cm 20 to 199.99mS/cm 0 to 9.99, 99.9, 999.9 ppm; 9.99, 99.9 ppt, max. 199.9 ppt based on factor settings 0.0ºC to 100.0oC; Resolution 0.05% Full Scale Accuracy Calibration 0.1oC ±1% full scale ±0.5°C 4 points (1 per range) Auto 5 points (1 per range) Manual Description EN16-140 Conductivity / pH / TDS / oC Hand Held Meter EN16-138 Replacement conductivity / TDS electrode, ultem-body with 6 pin connector Mobile Laboratories Catalogue No Laboratory Analytical Equipment Measurement Noise & Vibration Monitoring Specification Air Quality Monitoring • Multi parameter, portable instrument for measuring Conductivity, Temperature and TDS • Stores and recalls up to 16 sets of readings • Convenient data transfer with RS232 output • Multi-point calibration for unprecedented full-range accuracy • Advanced setup allows you to customise meter parameters • Self-diagnostic messages, Hold function, Ready indicator, Auto-off features • Supplied complete with carrying case, bottles, calibration standards and conductivity electrode Air / Dust Sampling & Monitoring Conductivity / TDS / oC Hand Held Meter Toxic Gas Detection Catalogue No Meteorology Measurement Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Conductivity / TDS / oC Hand Held Meter Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 42 EN16-144 Air/ Dust Sampling & Monitoring Toxic Gas Detection Specification Air Quality Monitoring Noise & Vibration Monitoring Laboratory Analytical Equipment Training Mobile Laboratories 43 Conductivity / pH / TDS / oC Waterproof, Hand Held Meter • Waterproof and Dustproof Housing - IP67 rated, ideal for rugged harsh conditions. Plus it floats! • Multi-parameter - toggle between pH/temperature and Conductivity/ temperature at touch of buttons • Multi-Point Push-button Calibration (up to 3/4 points for pH/Conductivity) - for easy, quick calibration • Auto-Ranging for Conductivity measurements for fast response and best resolution over measurement range • User-Customization for enhanced flexibility and viewing of Conductivity/TDS effective cell constants per range, electrode diagnosis - pH slope/offset/mV base value, previous calibration points, etc. • Stability Indicator prompts whenever reading stabilizes • Auto-Hold Function automatically freezes reading when stabilized for easy viewing and recording • Easy Interchangeability of electrodes caters for other specialty electrodes for specific applications • Rugged Carrying Case (Included) provides handy on-site meter calibration and measurement Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing EN16-148 Measurement Conductivity TDS Temperature pH Range 0 to 19.99, 199.9, 1999 µS/cm 0 to 19.99, 199.9 mS/cm 0 to 9.99, 99.9, 999.9 ppm; 9.99, 99.9 ppt, max of 199.9 ppt (based on factor setting) 0.0ºC to 100.0ºC -2 to 16 Resolution 0.01, 0.1,1 µS/cm; 0.01, 0.1 mS/cm 0.01, 0.1, 1 ppm; 0.01, 0.1,1 ppt 0.1ºC 0.01 Accuracy ±1% full scale ±0.3ºC ± 0.01 Calibration 5 points (1 per range) ±5.0ºC (0.1ºC increments) Up to 5 Catalogue No Description EN16-144 Conductivity / pH / TDS / oC Waterproof, Hand Held Meter EN16-116 Replacement pH electrode, plastic body, gel filled EN16-138 Replacement conductivity / TDS electrode, ultem-body with 6 pin connector Conductivity / TDS / oC Bench Meter • Low Cost, high performance meter for measuring Conductivity and TDS with auto-ranging capability for fast response, with ±1% full scale accuracy • Up to 1 or 5-point automatic or manual calibration • Non-volatile memory stores and recalls up to 50 data sets of conductivity, TDS readings with temperature • Advanced setup allows you to customise meter parameters • Supplied with conductivity electrode (k=1), integral electrode holder and power adapter Specification Measurement Conductivity TDS Temperature Range 0 to 19.99, 199.9, 1999 µS/cm 0 to 19.99, 199.9 mS/cm 0 to 9.99, 99.9, 999.9 ppm; 9.99, 99.9 ppt, max of 199.9 ppt (depending on factory setting) -10ºC to 110.0ºC Resolution 0.01, 0.1,1 µS/cm; 0.01, 0.1 mS/cm 0.01, 0.1, 1 ppm; 0.01, 0.1,1 ppt 0.1ºC Accuracy ±1% full scale + 1 digit ±0.3ºC Calibration 5 points (1 per range) ±5.0ºC (0.1ºC increments) Catalogue No Description EN16-148 Conductivity / TDS / oC Bench Meter EN16-150 Replacement conductivity / TDS electrode, ultem-body with 6 pin connector www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-152 • Multi parameter waterproof instrument for measuring Dissolved Oxygen (D.O.) and Temperature • Non-volatile memory stores and recalls up to 50 sets of D.O. readings (mg/1 or ppm or % saturation) with temperature (oC/oF) • Real-time clock stamps stored data and calibration data with time / date • Advanced setup allows you to customise meter parameters view calibration data, electrode diagnosis etc • Automatic compensation for salinity and barometric pressure • Self-diagnostic messages, HOLD function, Ready indicator, Auto-off features • Supplied with carrying kit and bottles for solution, submersible D.O. probe and D.O. probe maintenance kit Specification mg/1 (ppm) % Saturation Temperature Range 0.00 to 20.00 mg/1 (ppm) 0.0 to 200% 0 to 100.0ºC Resolution 0.01 mg/1 (ppm) 0.1% 0.1ºC Accuracy ±1.5% full scale ±1.5% full scale ±0.3ºC Calibration 1 point (100% air saturation or in air saturated water); plus separate mg/1 (ppm) offset Catalogue No Description EN16-152 Dissolved Oxygen, Waterproof, Hand Held Meter EN16-154 Replacement galvanic dissolved oxygen electrode with ATC, 3m cable Meteorology Parameter ±5.0ºC (0.1º increments) Toxic Gas Detection EN16-156 Replacement galvanic dissolved oxygen electrode with ATC, 3m cable Mobile Laboratories Dissolved Oxygen / °C Bench Meter EN16-157 Laboratory Analytical Equipment Description EN16-156 Noise & Vibration Monitoring Catalogue No Air Quality Monitoring Designed for optimal performance and versatility, the D.O. meter come with intuitive, advance set-up options for extensive user-customization at an affordable price. Meter comes with self-stirring probe and bi-directional RS232 – ideal for BOD and other Dissolved Oxygen applications in the laboratory. • Measures Dissolved Oxygen in % saturation, ppm, mg/L at ±0.5 % full scale accuracy • Automatic calibration at 100 % and independent 0 % – greater measurement sensitivity during low oxygen levels • Accurate readings in varying conditions with Temperature, Salinity and Barometric Pressure Compensation • Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance • Bi-directional RS232 for easy data transfer to computer • Cal-due alarm – no more out-dated calibrations • Auto-logging function for convenient continuous monitoring • Limit alarm alerts when reading falls out of range • Password protection for setup and calibration Air / Dust Sampling & Monitoring Dissolved Oxygen / °C Bench Meter Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Dissolved Oxygen, Waterproof, Hand Held Meter Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 44 EN16-158 • D.O. measurement includes five-day BOD testing, OUR, and SOUR. Simple D.O. measurement ranges from 0 to 60 mg/L and 0 to 600% saturation • Advanced real-time on-screen graphing function provides useful indication for specific measurements • Extensive setup screens enable you to customise meter to your needs, e.g. Barometer and Salinity Setting, BOD / OUR / SOUR Configuration, Alarm Limits and other functions • Advanced USB, IRDA connectivity allows extensive host / device communication capabilities • Ethernet / Internet-ready with RJ45 input for connection to LAN or Internet for quick online research and data sharing • Secure log-in for up to ten users Specification Measurement Dissolved Oxygen % Saturation of Oxygen Temperature Range 0 to 60mg/L or ppm 0 to 600% 0 to 45°C Resolution 0.01mg/L or ppm 0.1% 0.1°C Toxic Gas Detection Accuracy ±0.5% Full scale + 1 LSD Memory 100 Data Sets Output USB, IrDA, RS232C Power Requirements EN16-162 ±0.1°C 9V DC Adapter, 3.3mA Dimensions (wxdxh) cm Air/ Dust Sampling & Monitoring Air Quality Monitoring Noise & Vibration Monitoring Dissolved Oxygen / BOD / °C Bench Meter Touch screen simplicity and versatility make the Dissolved Oxygen (D.O.) Bench Meter the most advanced benchtop D.O. meter available and the easiest to use. Enter seed volume and other BOD data and it will take care of the rest. Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 23.5 x 16.5 x 8.9 Catalogue No Description EN16-158 Dissolved Oxygen / BOD / °C Bench Meter EN16-160 Dissolved Oxygen / BOD electrode with self stirring mechanism, 1m cable Turbidity Meter Hand held waterproof Turbidity meter • Auto-ranging up to 1000 NTU • Multi-point automatic calibration (up to 4 points) • Self-diagnostic messages, quick stable responses and maintenance-free • Infra-Red light source • Supplied with calibration kit and carrying case Range 0 to 1000 NTU Resolution 0.01, 0.1, 1 NTU (dependent on measurement & range) Accuracy ±2% / ±3% of reading Calibration Push button at 0.02, 20.0, 100 & 800 NTU Dimensions (WxLxH), mm 68 x 155 x 46 Weight, g 200 Catalogue No Description EN16-162 Turbidity Meter Training Mobile Laboratories Laboratory Analytical Equipment Specification 45 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-164 A highly accurate Turbidity meter especially designed for water quality measurements. Meets and exceeds the requirements of USEPA and Standard Methods. The instrument is based on a state-of-the-art optical system which guarantees accurate results, long term stability and minimizes stray light and colour interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration. • Multi-Range through 0-4000 NTU • 2, 3,4 or 5 point calibration with supplied standards • Good Laboratory Practice (GLP) function for traceability of calibration conditions • User friendly Graphical LCD display with guidance notes • Log up to 200 records Specification 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU Resolution 0.01; 0.1; 1 NTU Range Selection Automatically Accuracy ±2% of reading plus 0.02 NTU ±5% of reading above 1000 NTU ±1% of reading or 0.02 NTU whichever is greater Stray Light < 0.02 NTU Light Detection Silicon Photocell Method Nephelometric method (90°) Measuring mode Normal, Average, Continuous Turbidity Standards <0.1, 15, 100, 750 and 2000 NTU Calibration Two, three, four or five-point calibration Light Source Tungsten filament lamp Lamp life greater than 100,000 readings Display 40 x 70mm graphic LCD (64x128 pixels) with backlight Logging Memory 200 records Serial Interface USB Power Supply 230 V / 50 Hz or 115 V / 60 Hz 20 W Auto Shut-off After 15 minutes of non-use Toxic Gas Detection Repeatibility Meteorology Range Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Turbidity Bench Meter Air / Dust Sampling & Monitoring Air Quality Monitoring Bench Turbidity Meter supplied with 5 sample cuvettes and caps, calibration cuvets, silicone oil, tissue for wiping cuvettes, power adapter and instruction manual. EN16-166 Calibration set for turbidimeter EN16-168 Solution for cleaning cuvettes EN16-170 Silicon oil (15 mL) EN16-172 Tissue for wiping cuvettes EN16-174 Glass cuvettes EN16-176 Caps for cuvettes EN16-178 Windows® Compatible Software Laboratory Analytical Equipment Description EN16-164 Noise & Vibration Monitoring Catalogue No Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 46 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 47 Salinity Waterproof Pocket Meter EN16-180 • Direct temperature readout • Large screen dual-display • Automatic Temperature Compensation (ATC) • Waterproof to IP67 standard Specification EN16-180 Salinity range To 10.00 ppt Salinity resolution 0.10 ppt Salinity accuracy ±1% Full scale Temperature range 0 to 50°C Temperature resolution 0.1°C Temperature accuracy ±0.5°C Power 4 x 1.5v A76 Micro Alkaline Batteries. Life: 50 Hours Dimensions, cm 16.5 x 3.8 Salinity Hand Held Meter EN16-184 • Measures salinity in ppt and in % • Temperature measurement with 0.1°C resolution • Push button calibration with ±1% full scale accuracy • Electrode with built-in ATC • Protective rubber boot also acts as a stand • Supplied with carrying case and standard solutions Specification EN16-184 Salinity range 1.0 to 50.00 ppt / 0.1 to 5.00% Salinity resolution 0.1 ppt / 0.01% Salinity accuracy ±1% Full scale Temperature range -10 to 100°C Temperature resolution 0.1°C Temperature accuracy ±0.5°C Power 4 x 1.5v, AAA Batteries, Life: 100 Hours Dimensions, cm 15.7 x 8.5 x 4.2 Buffer Tablets Ideal for when small amounts of buffer are required to quickly calibrate a pH meter in the laboratory or field. Distilled water is added to the tablet which dissolves to give a standard pH buffer solution. Catalogue No Description EN16-200 pH buffer tablets, pH 4, Box of 50 EN16-202 pH buffer tablets, pH 7, Box of 50 EN16-204 pH buffer tablets, pH 10, Box of 50 Buffer and Calibration Solutions for pH and Multi-Parameter Meters Buffers and calibration solutions for pH, REDOX and Conductivity, packed in 500ml leak-proof bottles. Economical and popular for laboratory use. Catalogue No Description EN16-206 pH buffer solution, pH 4, 500ml EN16-208 pH buffer solution, pH 7, 500ml EN16-212 pH buffer solution, pH 10, 500ml EN16-214 Conductivity standard solution, 1413 µS, 500ml EN16-216 Conductivity standard solution, 12.88 mS, 500ml EN16-218 Conductivity standard solution, 111.8mS, 500ml EN16-220 Redox standard solution, 258mV, 500ml EN16-222 Redox standard solution, 458mV, 500ml www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis pH / ORP/ ION / Conductivity / TDS / Salinity / Resistivity / °C Bench Meter EN16-224 Your all-in-one solution for multi-parameter research work in the lab. Reliable, accurate and intuitive with user-friendly functions. The meter comes with a multi-data screen that includes temperature, electrode status, calibration points, date and time along with your desired measurement parameter, measures pH, ORP, ION, Conductivity, TDS, Salinity, or Resistivity. Meteorology • Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy • Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button • Up to 6-point calibration with auto-buffer recognition • Includes high performance 4-cell Conductivity probe • Quick, easy electrode diagnosis with the effective cell constants display • Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance • Bi-directional RS232 for easy data transfer to computer • Cal-due alarm – no more out-dated calibrations • Auto-logging function for convenient continuous monitoring • Limit alarm alerts when reading falls out of range • Password protection for setup and calibration • Automatic temperature control • Mains power 110 / 240 V Parameter Range pH ORP ION ±2000.0 mV Concentration TDS Salinity Resistivity 0.050 µS to 500.0 mS 0.050 ppm to 500 ppt (@TDS factor 1.00 0.0 to 80.0 ppt 2.000 Ohm to 20.0 MOhm Temperature 0.0 to 100.0°C 0.01 / 0.1 Ohm; 0.001 / 0.1 KOhm; 0.01 MOhm ±1% full scale 0.1°C 0.001 TO 19999 PPM (±2000 mV) Rel. mV Range ±2000.0 mV 0.1 / 0.01 / 0.001 pH Accuracy ±0.002 pH + 1LSD Calibration points Up to 6 preset or 5 custom Buffer Sets USA, NIST, DIN User 1, User 2, Custom 0.1 mV 2 or 3 digits 0.01/0.1 µS ; 0.001 / 0.01 / 0.1 mS 0.01 / 0.1ppm; 0.001 / 0.01 / 0.1 ppt 0.01 / 0.1 ppm; 0.001 / 0.01 / 0.1 ppt ±0.2 mV 0.5% full scale (monovalent); 1% full scale (divalent) ±5% full scale ±1% full scale ±1% full scale 2 to 8 Up to 5 Up to 5 ±0.3°C Noise & Vibration Monitoring Resolution Air Quality Monitoring Conductivity Air / Dust Sampling & Monitoring -2.000 to 20.000 pH Toxic Gas Detection Specification Description EN16-224 pH / ORP / ION / Conductivity / TDS / Salinity / Resistivity Bench Meter EN16-122 Replacement ion / pH electrode EN16-226 4 Cell Conductivity / ATC Electrode, Graphite Sensor, Epoxy Body Laboratory Analytical Equipment Catalogue No Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 48 EN16-230 Conductivity / TDS / Resistivity / °C Bench Meter Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the meter accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once. • Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy • Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button • Quick, easy electrode diagnosis with the effective cell constants display • Replatinization in 5 minutes with the built-in replanitization circuit • Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance • Bi-directional RS232 for easy data transfer to computer • Cal-due alarm – no more out-dated calibrations • Auto-logging function for convenient continuous monitoring • Limit alarm alerts when reading falls out of range • Password protection for setup and calibration • Mains power 110 / 240 V Specification Parameter Conductivity TDS Salinity Resistivity Temperature Range 0.050 µS to 500.0 mS 0.050 ppm to 500 ppt (@ TDS factor 1.00) 0.0 to 80.0 ppt 2.000 Ohm to 20.0 MOhm 0.0 to 100.0 ºC Normalization 15.0 to 30.0 ºC Resolution 0.01 / 0.1 µS; 0.001 / 0.01 / 0.1 mS 0.01 / 0.1 ppm; 0.01 / 0.1 ppm; 0.01 / 0.1 Ohm ; 0.1 ºC 0.001 / 0.01 / 0.001 / 0.01 / 0.001 / 0.1 kOhm; 0.1 ppt 0.1 ppt 0.01 MOhm Accuracy ±1 % full scale ±1 % full scale ±1 % full scale ±1 % full scale ±0.3 ºC Coefficient Linear & pure; 0.000 to 10.000 % Compensation ATC / MTC Calibration points Up to 5 Catalogue No Up to 5 Description EN16-230 Conductivity / TDS / Resistivity / °C Bench Meter EN16-226 Replacement – 4-Cell Conductivity / ATC Electrode, Graphite Sensor, Epoxy-Body Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 49 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-232 Specification Conductivity TDS Salinity Resistivity Temp Range 0 to 200µS/cm 200 to 2000µS/cm 2 to 20mS/cm 20 to 500mS/cm 0 to 200ppm 200 to 2000ppm 2 to 20ppt 20 to 200 ppt 0 to 90ppt 0 to 19.99kû 20 to 199.9kû 200k_ to 1.999Mû 2. to 100Mû -5 to 105°C Resolution 0.001 / 0.01 / 0.1µS / cm 0.001 / 0.01 / 0.1mS/cm 0.001 / 0.01/0.1ppm 0.001 / 0.01 / 0.1ppt 0.1 / 0.01 / 0.001ppt 0.1 / 0.01 / 0.001kû 0.1°C 0.01 / 0.001Mû ±0.5% Full Scale + 1 digit ±0.2°C 4 points Auto & Manual Dimensions, cm, (wxdxh) 23.5 x 16.5 x 8.9 Description EN16-232 Conductivity / TDS / Salinity / Resistivity / °C Bench Meter EN16-234 Epoxy -body 4 ring conductivity electrode with ATC, Cell constant K=1.0, DIN connector, 1m cable Require General Laboratory Equipment? Please refer to our General Lab Catalogue. Noise & Vibration Monitoring Note: Air Quality Monitoring Catalogue No Air / Dust Sampling & Monitoring Accuracy Calibration Toxic Gas Detection Measurement Meteorology •Single and Multi point standardisation for Conductivity, Resistivity, TDS and Salinity measurements using two-cell and four-cell probes, with built-in replatinising circuit •Advanced real-time on-screen graphing function provides useful indication for specific measurements •Extensive setup screens enable you to customise meter to your needs, e.g. Cell Constant, Temperature Coefficient, TDS factor, Alarm Limits and other functions •Windows® CE-driven, full-colour touch screen provides unmatched ease of use in operations and setups with user-friendly icons, user prompts and context specific ‘help’ screens •Advanced USB, IRDA connectivity allows extensive host / device communication capabilities •Ethernet / Internet-ready with RJ45 input for connection to LAN or Internet for quick online research and data sharing, with secure log-in for up to ten users. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Conductivity / TDS / Salinity / Resistivity / °C Bench Meter Laboratory Analytical Equipment Mobile Laboratories Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 50 Multi-Parameter Water Quality Meters Multi-parameter Water Quality Monitor This monitor is capable of measuring up to 11 parameters in the field simply by submerging the probe into a water course and using the control unit to run the test and view results. Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing Innovative sensor technologies combine with a durable and ergonomic design making this instrument simple to use, rugged, and easy to maintain in the field. Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection EN16-300 51 An integrated GPS system allows users to identify exactly where results were taken and record other location information, providing more informative analyses. The instrument can be used to measure both surface and ground water in a variety of settings such as rivers, lakes, industrial systems, wells and bore-holes. Features • Easy to read LCD screen – clear display even in bright sunlight conditions • Integral GPS receiver for position tagging of readings – adds context to your results to facilitate environmental surveys • Built-in data logger - store 1900 results on the meter and then download these to a computer via USB • Simple to use, multi-lingual menu system – control all setup, calibration and test procedures • Shock resistant and waterproof casing Meter Specification Display 80 Character FSTN LCD with backlight Data Memory 1900 full sets plus GLP data GPS Receiver 12 channels with integral antenna GPS Accuracy ± 10m in all 3 dimensions Atmospheric Pressure 150mb - 1150mb ± 1mb Languages English / French / Spanish (German on request) PC Interface USB (cable provided) Power Supply 5 x AA cells, Alkaline, or Ni-MH rechargeable Battery Life Alkaline >20 hours Ni-MH >40 hours Operating Temperature -20ºC - +70ºC Protection Class IP67 (30 mins at 1m) Dimensions, mm (H x W x D) 180 x 90 x 39 Weight, g (inc. batteries) 450 Probes Specification Protection Class IP68 (permanent immersion at 10m) Immersion Depth min 75mm, max 30m Operating Temperature -5ºC - +50ºC Dimensions, mm (L x H) 290 x 48 Weight, g (incl. cable) 725 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing EN16-300 Control Unit with integral GPS, supplied complete with 5AA Alkaline Cells, USB cable, instruction manual and software, with carrying case. Probe not included. PROBES EN16-315 EN16-314 EN16-313 EN16-312 EN16-311 depth dissolved oxygen (galvanic) dissolved oxygen (optical) orp ph resistivity salinity range 0 - 200 mS/cm (200,000 µs/cm) resolution 3 Auto-range scales: 0 - 9999 µS/cm, 10.00 - 99.99 mS/cm accuracy ± 1% of reading or ± 1 µS/cm if greater ✔ ✔ ✔ ✔ ✔ – ✔ range 0 - 30 m (0 - 100 F) resolution 0.01 m (0.01 F) accuracy ± 0.1 m (± 4 F”) ✔ * * * * * * * range 0 - 500% / 0- 50.00 mg/L resolution 0.1% / 0.01 mg/L accuracy ± 1% of reading * * ✔ ✔ ✔ ✔ – ✔ range 0 - 500% / 0- 50 mg/L resolution 0.1% / 0.01 mg/L accuracy ±1% of reading (0-200%, 0-20mg/L) or ±10% (200-500%, 20-50mg/L) ✔ ✔ * * * * * * range ± 2000 mV resolution 0.1 mV ✔ ✔ ✔ ✔ O O O – accuracy ± 0.5 mV range 0 - 14 pH / ± 625 mV resolution 0.01 pH / ± 0.1 mV accuracy ± 0.01 pH / ± 0.5 mV ✔ ✔ ✔ ✔ ✔ ✔ ✔ – range 5Ω cm - 1MΩ cm resolution 2 Auto-range scales: 5 - 9999Ω cm, 10.0 - 1000.0 KΩ cm accuracy ± 1% of reading or 1 Ω cm if greater ✔ ✔ ✔ ✔ ✔ ✔ – ✔ range 0 - 70 PSU / 0 - 70 ppt (g/Kg) resolution 0.01 PSU / 0.01 ppt accuracy ± 1% of reading or ± 0.1 unit if greater ✔ ✔ ✔ ✔ ✔ ✔ – ✔ seawater specific gravity range 0 - 50 resolution 0.1 accuracy ± 1.0 ✔ ✔ ✔ ✔ ✔ ✔ – ✔ range 0 - 100,000 mg/L (ppm) tds resolution 2 Auto-range scales: 0 - 9999 mg/L, 10.00 - 100.00 g/L accuracy ± 1% of reading or ± 1 mg/L if greater ✔ ✔ ✔ ✔ ✔ ✔ – ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ – ✔ – ✔ – t range -5ºC - + 50ºC (23ºF - 122ºF) resolution 0.1ºC / F accuracy ± 0.5ºC range 0 - 1000 NTU resolution 2 Auto-range scales: 0.0 - 99.9 NTU, 100-1000 NTU repeatability ± 2% of auto-ranged scale * = OPTIONAL – = NOT AVAILABLE ON THIS PROBE Additional Accessories O = OPTIONAL ORP ELECTRODE REPLACES pH ELECTRODE Calibration & Maintenance Solutions Catalogue No Description EN16-341 Heavy Duty Flow-Through Cell EN16-360 300ml Calibration Solution EN16-342 5m Extension Cable EN16-361 600ml Calibration Solution EN16-343 10m Extension Cable EN16-362 300ml pH7.00 Buffer EN16-344 30m Extension Cable EN16-363 600ml pH7.00 Buffer EN16-345 Galvanic Dissolved Oxygen Membrane Kit EN16-364 300ml pH4.01 Buffer EN16-346 Optical Dissolved Oxygen Sensor Cap EN16-365 600ml pH4.01 Buffer EN16-347 pH / ORP Electrode Storage Cap EN16-366 150ml Zero Oxygen Solution EN16-348 Replacement pH Electrode EN16-367 600ml Zero Oxygen Solution EN16-349 Optional ORP Electrode EN16-368 25ml Dissolved Oxygen Filling Solution EN16-350 Combined pH / ORP Electrode EN16-369 25ml Storage Solution EN16-370 Calibration / Rinse Bottle Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Description Mobile Laboratories Catalogue No Laboratory Analytical Equipment ✔ = STANDARD FUNCTION Noise & Vibration Monitoring turbidity t t Air Quality Monitoring temperature Air / Dust Sampling & Monitoring EN16-316 conductivity Toxic Gas Detection EN16-317 ✔ (except EN16-312), pH storage cap (except EN16-311) and instruction manual. Meteorology EN16-318 Probes are supplied with a 3 metre cable (extensions available), calibration solution, rinse bottles, dissolved oxygen membrane kit Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis MULTI-PARAMETER WATER QUALITY MONITOR 52 Training Mobile Laboratories Laboratory Analytical Equipment Noise & Vibration Monitoring Air Quality Monitoring Air/ Dust Sampling & Monitoring Toxic Gas Detection Meteorology Soil / Sediment Hydrology & Water Quality Sampling & Groundwater Testing Analysis Water Quality Testing 53 Remote Water Quality Monitoring Paqua-Stat Automatic Water Quality Monitoring Stations The Paqua-Stat is a remote water quality monitoring station that enables real-time analysis of water courses from any global location. The integration of state-of-the-art telemetry with proven sensor technology provides a system that can be installed and then monitored remotely via an internet connection. The ecology of the world’s water courses is finely balanced; temperature, oxygen levels and conductivity are all inter-related. Pollution can alter these parameters and destabilise the system with potentially devastating effects. Routine monitoring is essential to observe changes and react quickly. With Trace2o’s low cost Paqua-Stat this can be achieved. The Paqua-Stat uses the Quad-band GSM / GPRS network to transmit realtime data to a secure web location accessible via a user log-in. Graphical interpretation of the data illustrates immediately any water quality parameters that have gone out-of-range. Alarm levels can also be set such that these results will trigger a text message to be sent to the site manager or engineer. In a situation where GSM coverage is not available, radio telemetry options are available to expand the range to a 15km radius of the GSM hub. The Paqua-Stat’s modular design enables customer configurable options with the ability to add flow cells, different sensors, different power options (e.g. solar panel), and to connect with other existing equipment, such as weather stations. • Modular design • Remote water quality monitoring, reducing the requirements for site visits • 15km range with no GSM coverage • Messaging system to alert user to error conditions • Compact design for borehole, deep water and other course sampling • Live result feed from site to local PC • Low maintenance • Up to 17 parameters can be measured simultaneously (dependent on combination of probes) Manufactured from marine grade aluminium, the probe housing will survive for years even in the harshest environment. The majority of the probes should not require replacement and are sealed into the housing, which is epoxy-filled. This guarantees a 100% watertight unit that can be submerged indefinitely in the flow cell. The probes are designed to be anti-fouling but should maintenance be required the probe can be quickly removed from the flow cell for inspection. The optional Trace2o calibration meter allows for simple and fast recalibration in the field. www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Water Quality Testing Sampling occurs automatically Insert pump into water Telemetry system transmits results to analysis centre Range Resolution Optical Range Resolution -5 to +50°C 0.1°C Turbidity 0-3000NTU 0.01NTU pH 0 - 14 0.01 Chlorophyll 0-500ppb 0.1ppb Conductivity 0-100mS 1µS Blue-green algae 0-300,000cells/ml 1cell / ml Resistivity 5-1000Ωcm 1Ωcm Rhodamine WT dye 0-500ppb 0.1ppb Salinity 0-70ppt 0.01ppt Fluorescein dye 0-500ppb 0.1ppb DO 0-50mg/l 0.01mg/l Refined oil 0-10,000ppb 0.1ppb ORP ±2000mV 0.1mV TDS 0-100,000ppm 1ppm SSG 0-5 0.1 Ionic Range Resolution t t 0.01ppm 0-1000ppm 0.01ppm F- 0-1000ppm 0.01ppm NO3- 0-1000ppm 0.01ppm Ca2+ 0-1000ppm 0.01ppm Air Quality Monitoring 0-1000ppm Air / Dust Sampling & Monitoring NH4 / NH3 Cl- + Noise & Vibration Monitoring Note: Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Description Paqua-Stat Multi-parameter Remote Water Quality Monitoring Station(Standard System) Complete System, comprising Base Unit with Submersible Pump (18m head), Flow Cell, Telemetry Processing Unit, all connection tubing, Water Quality Probe with sensors for measuring the following parameters: Temperature, pH, Conductivity, Resistivity, Salinity, Dissolved Oxygen, ORP, TDS, SSG, and Turbidity, supplied with Lockable Cabinet, Solar Panel ( 85W with control unit and 6.4m mast), sealed 80Ah battery, Calibration Meter, Accessories Kit Box and all required fixtures and fittings. Mobile Laboratories Catalogue No Laboratory Analytical Equipment For NON standard bespoke Paquastat systems, requiring any of the above sensors and other communication options to suit end user and on-site requirements, please contact Wagtech Projects. EN16-500 Toxic Gas Detection General Temperature Meteorology Specification of Sensors Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Install Paqua-Stat by water course 54 Water Quality Testing Hydrology & Groundwater In any water resources assessment study, long term measurements of water quality, flow, level, and depth are crucial to produce accurate data for later processing andanalysis. This section contains a comprehensive range of equipment that is widely used for measuring and recording such data. Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Hydrology & Groundwater 55 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Hydrology & Groundwater EN26-104 Specification Range, m/sec 0.1-6.1 Accuracy, m/sec 0.03 Operating temperature, °C -20 to +70 Sensor type Turbo-Prop propeller with magnetic pick-up Datalogger 30 sets, min, max, avg Weight, kg 4 Power Internal batteries - approx 5 year life Catalogue No Description EN26-102 Flow Master, pole length; 1 to 2m EN26-104 Flow Master, pole length; 1.5 to 4.5m Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring • Highly accurate and low cost • Lightweight, rugged, and reliable • Debris shedding turbo-prop • Rain-proof digital read-out • Padded carrying case for easy storage • Displays instantaneous and true average velocity Toxic Gas Detection The Flow Master is a highly accurate low cost water velocity instrument for measuring flows in open flow channels and partially filled pipes. The instrument has been extensively used by water professionals for over 30 years. The Flow Master consists of the protected Turbo Prop positive displacement sensor coupled with the expandable probe handle to the digital readout display. The water instrument is ideal for storm water run-off studies, sewer flow measurements, measuring flows in rivers and streams, and also in monitoring velocity in ditches and canals. Meteorology Flow Master Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Current Flow Monitoring Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 56 EN26-106 Flow Meters Current Flow Meters are suitable for use in a wide variety of environments ranging from major rivers to small streams, fresh and salt water or effluent. Measurements can be made for river gauging, open channel flow, pollution and hydrometric studies. The Digital Display Unit (DDU) offers real time and averaged display of velocity with data logging. Data can be downloaded to a PC via the RS232 interface using the cable supplied. The DDU comes with an LCD display with optional backlight sealed to IP65 and weighing less than 1 kg. • Easy to use, robust, low maintenance design • Reliable and accurate velocity readings • Wide measurement range • Calibrated in accordance with BS3680 Specification Large Meter Small Meter Velocity range 0.03 to 10m/s 0.04 to 5m/s Accuracy ± 1.5% reading above 0.15m/s ± 2.5% reading above 0.5m/s ±0.004m/s below 0.15m/s ± 0.001m/s below 0.5m/s 125mm dia. by 0.27m pitch 50mm dia. by 0.10m pitch Impeller Materials Motor body Black Acetal Impeller High Impact Styrene Impeller shaft Stainless Steel on Jewelled Bearing Catalogue No Description EN26-106 Large Current Flow Meter - Wading set, Large Flow Meter, Digital Display Unit, 3 x 0.5m stainless steel wading rods, complete with base plate, direction knob, 2m cable, carrying case and operation manual. EN26-108 Large Current Flow Meter - Suspension Set Large Flow Meter, suspension bar digital display unit, 35m suspension cable, carrying case and operation manual. EN26-110 Small Current Flow Meter - Wading set, Small Flow Meter, Digital Display Unit, 3 x 0.5m stainless steel wading rods, complete with base plate, direction knob, 2m cable, carrying case and operation manual. EN26-112 Small Current Flow Meter - Suspension Set Small Flow Meter, suspension bar digital display unit, 35m suspension cable, carrying case and operation manual. EN26-110 EN26-106 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Hydrology & Groundwater 57 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Hydrology & Groundwater This small electromagnetic flow meter has been designed specifically for use in open channels where fouling by weed or sewage can be a problem. A high precision instrument which can be relied upon to give accurate readings (±0.5% of reading plus zero stability) over a wide flow range (±5 m/sec) in only 5cm of water. The control display unit provides a choice of averaging modes, standard deviation of the data, and a logging facility for recording up to 999 averaged readings. EN26-114 Two sensor types are available, to suit different application requirements. One for measuring speeds in water depths of 15cm or more, and one for 5cm or more. Both offer excellent durability, reliable accurate data, and are suitable for use in clean water and dirty or difficult environments. Specification Cylindrical Type -5m/s to +5m/s Flat Type ±0.5% of reading plus 5mm/s ±0.5% of reading plus 5mm/s ±0.004m/s below 0.15m/s Sphere of approx 12cm diameter around sensor <5mm/s Sensing Volume Minimum Depth 15cm 5cm Range -5m/s to +5m/s Toxic Gas Detection Accuracy Zero Drift Meteorology Both instruments are calibrated to NAMAS traceable standards for speeds up to 1m/s. Supplied with: 3m cable, control display unit (with logging facility), wading rod set c/w 3 x 0.5m graduated rods, base, direction knob and operation manual. Supplied complete in large carrying case. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Electromagnetic Flow Meters Cylinder of approx 20mm Ø x 10mm high Display Unit 25 x 16 x 10 / 2 Environmental Power Sealed to IP67 8 x alkaline C cells, lasting for up to 37 hours Operating Temp -5°C to +50°C (display unit) -5°C to + 40°C (sensor) Wading Set Dimensions, cm / weight, kg 62 x 42 x 34, / 9 Catalogue No Description EN26-114 Electromagnetic Flow Meter Wading Set with single axis cylindrical sensor (water depths of 15cm or more), EN26-116 Electromagnetic Flow Meter Wading Set with single axis flat sensor (water depths of 5cm or more), EN26-116 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Dimensions, cm / Weight, kg Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 58 Water Level Monitoring Water level measurements form the basis of hydrological soil examination (porosity of the soil, determination of the current direction of the groundwater etc.) Several widely used systems are displayed here that allow for the recording of water levels in applications such as in bore holes, casing tubes, well pipes, water wells, open water, and tanks. EN26-118 Portable Echo Sounder The Portable Echo Sounder is a low cost single beam water depth instrument, which is used by surveyors engaged in river, lake and inshore hydrographic surveying. The instrument can be used as a conventional echo sounder with depth data output via a RS232 serial port. The unit is sold as a complete package and includes transducer, leads internal battery charger and a heavy duty carrying case • Measures water depths down to 75m. • Light weight and easy to use in a small boat. • Internal memory stores data for processing. • Graphic LCD display shows depth data continuously. • Can be connected to separate GPS equipment if required. Specification Transducer Frequency Beam Spread 200 KHz Depth Range 0.30m to 75m (software limited) Accuracy ±0.025m (RMS) Power 10 V x 1.5 AH Internal Nickel Hydride sealed battery (NIMH) Battery Life 8-12 hrs between charges Standby battery life 10,000 hrs Temperature range 0-45˚C Overall Dimensions, mm 100 x 220 x 45 Unit Box Weight, Kg 0.75 Catalogue No Description EN26-118 Supplied complete with boat transom mount active transducer, software package, serial data lead, battery charger and a rugged carrying case. 8-10 degrees Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Hydrology & Groundwater 59 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Hydrology & Groundwater EN26-120 A Water Level Monitor consisting of a datalogger with a submersible pressure transducer for remote monitoring and recording of water level, flow and pressure data. Constructed with an acrylic coat to protect the electronics from condensation. This water testing instrument is easy to use and install, and can be used in various applications such as groundwater monitoring, irrigation canals, wetlands, infiltration / inflow studies and many more. • Water level logger records over 81,000 readings • Measures water depth down to 150m • Accurate water level measurements ranging from 1m to 76m • Automatic barometric pressure and temperature compensation Data Logger Non-volatile flash memory Battery life Up to 1 year Resolution 12 bit 0-95% non-condensing 81,759 time and date stamped data points Enclosure, mm 48 x 292, weather resistant cylindrical enclosure Weight, kg 0.7 (inc battery and cable) Communication USB Toxic Gas Detection Humidity Storage capacity Meteorology Memory Pressure Transducer Accuracy ±0.1% of full scale at constant temperature, ±0.2% Material Stainless steel housing and microscreen Cable Standard 7.5m (other lengths available up to 150m) Catalogue No Description EN26-120 Water level Monitor: Supplied with datalogger, housed in a Weatherproof cylindrical enclosure, pressure sensor, PC software, 7.5m of cable and 9Vdc battery EN26-122 Extra cable lengths per metre, up to 150 metres Surface Water Installation Groundwater Installation Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Length Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Water Level Monitor Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 60 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Hydrology & Groundwater 61 Water Level Logger & Sensor Water Level Logger Kits These water level data loggers offer high accuracy at an affordable price, with no cumbersome vent tubes or desiccants to maintain. They are ideal for recording water levels and temperatures in shallow wells, streams, lakes and freshwater wetlands. Water Level Logger Kit • Available in 4 depth ranges • No-vent-tube design for easy and reliable deployment • Durable ceramic pressure sensor for reliable performance • Memory: 21,700 combined pressure and temperature measurements • Sample rate: 1 second to 18 hours, fixed or multiple-rate up to 8 userdefined sampling intervals • Battery life: 5 years (typical) — factory-replaceable • Fully-sealed housing ensures many years of trouble-free operation. • Suitable for deployment in water or air; case materials resistant to fuels, solvents and lubricants. • Calibration certificate included Includes calibration certificate of accuracy in accordance with NIST-traceable standards at three pressure points distributed throughout the range. Water Level Logger Specification Range Factory Calibrated Range (0° to 40° C) 0-4 m 0-9 m 0-30 m 69 to 145 kPa 69 to 207 kPa 69 to 400 kPa ±0.3 cm ±0.5 cm ±1.5 cm Water Level Accuracy (Typical Error) Resolution Burst Pressure 0.14 cm 0.21 cm 0.41 cm 310 kPa 18 m depth 310 kPa 18 m depth 500 kPa 40.8 m depth Waterproof Shuttle • Can be used either as a data shuttle or an Optic USB Base Station • Supports all Optic USB loggers • Outdoor or underwater data readout • Convenient direct USB connection to host computer • Waterproof to 20 m • Checks and indicates its own battery status Specification 4 MB non-volatile memory Up to 63 loggers Operating temperature range 0° to 50°C Battery life 1-year (typical) - user-replaceable Software Pro software Dimensions, cm / Weight, g 15.2 x 4.8 / 150 Base Station • Provides fast optical infrared (IR) communications for easy launch and read out of all Pendant loggers • Connects via USB cable to host computer while Coupler attaches the logger to Base Station • Splash-resistant Specification Operating temperature range Range 0° to 50° C Cable length 180 cm Offloads full 64K logger 30 Seconds www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Hydrology & Groundwater Optional additional logger for barometer pressure compensation Suspension cable Ground level Carrying Case Dimensions, cm 40 x 25 x 5 Weight, kg 3 Toxic Gas Detection Specification EN26-124 EN26-126 EN26-128 Logger Range One logger 0-4m Kit includes two 0-4m loggers One logger 0-9m EN26-130 Communications Base station Waterproof shuttle Base Station Not included Included Not included Kit includes one 0-4m and one 0-9m logger Waterproof shuttle Included EN26-132 EN25-134 One logger 0-30m Kits includes one 0-4m and one 0-30m Base Station Waterproof shuttle Not included Included Included Software Stainless steel Logger Housing Dipmeter EN26-138 This range of dipmeters are robust, light and convenient in use, and are all fitted with an extremely strong tape marked in metres and centimetres. The tape is wound on a plastic coated metal carrying frame. Powered by a 9V PP3 battery, the dipmeters produce an amplified audio signal (buzzer) when the probe contacts a water surface. • Shrouded probe, stainless steel, 15mm diameter x 175mm length • Lightweight and durable • Reinforced flat tape with close interval markings • Variable sensitivity control Length of tape EN26-136 20m EN26-138 50m EN26-140 100m EN26-142 150m EN26-144 200m Training Training Catalogue No * Longer lengths available on request Telephone: +44 (0)1635 872 929 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Water Level Logger Kits Catalogue No Carrying Case Meteorology Water level Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Water Level Logger Kit www.wagtechprojects.com [email protected] 62 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Hydrology & Groundwater 63 Geophysical Testing Geophysical techniques are widely used in remote regions of the world where groundwater records may be non-existent to locate and map underground water resources. EN26-146 Earth Resistivity Kit This Earth Resistivity Meter provides excellent and reliable performance in a convenient, robust and fully portable design. Ideally suited for subsoil groundwater prospecting at shallow, medium and great depth, it can also be used for geological stratigraphy, studies of salt water contamination in fresh water layers, landslide monitoring, mineral exploration and archaeological research. • Creation of energetic wave based upon the parameters supplied by the user • Fast downloading of data through RS232 • Easy to operate menu for quick learning • More than 50 hours of battery life • Automatic calibration at every switch-on • Light and compact structure in a sturdy weatherproof case Earth Resistivity Kit comprises of the following: • Earth Resistivity measuring unit • Cable reel with 300m cable (section 1mm) x 2 • Cable reel with 100m cable (section 1mm) x 2 • Rechargeable accumulator (200V, 500mA) x 2 • Copper electrode x 2 • Inox steel electrode x 2 • 1.25kg Mallet x 2 Specification Energization Curve May be customised to suit the following parameters: Positive and negative wave length: 0.1 - 9.9 seconds (impl. at 25 seconds) Time between positive and negative wave: 0.1 - 9.9 seconds Intercycle time: 1 - 99 seconds Number of cycles: 1 - 99 Resolution 610 nV, 126, 8nA Number of readouts per wave 3 readouts of voltage and 3 readouts of current, consecutively and at wave term Voltage range for VMN From +/-20mV to +/-1280 V (automatically selected) Memory Up to 1500 measures Recommended energiser 600V (1200V peak-peak), 0.5A max Noise suppression Superior to 98 db at 50-60 Hz Power supply 2x internal rechargeable battery 6V - 4A/h Operating temperature 0 - 60°C Physical dimensions, cm 38 x 27 x 15 (shock proof case) Weight, kg 7 Catalogue No Description EN26-146 Earth Resistivity Kit www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Hydrology & Groundwater Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Water Sampling EN26-152 The Van Dorn Water Sampler is designed for vertical and horizontal deployment, and is ideally suited for use in marine or fresh water environments. The device has no internal metal parts, making it suitable for obtaining samples for heavy metal analysis and a clear acrylic body enabling a clear visual inspection of the sample. Weight 5Kg EN26-148 Vertical Style, Capacity 1000ml EN26-150 Vertical Style, Capacity 2000ml EN26-152 Horizontal Style, Capacity 1000ml EN26-154 Horizontal Style, Capacity 2000ml Water Sampler Field Kit EN26-156 This water sampler field kit is ideal for water sampling at any depth zooplankton collection, and secchi disc transparency measurements. The kit is supplied complete with, clear polycarbonate 1.0 litre vertical water sampler, 200g messenger, 20cm limnological secchi discs; armoured thermometer(liquid spirit filled,-5˚C to 40˚C in 0.5˚ graduations); student plankton net (20cm diameter x 60cm length x 153µm); three calibrated lines with 0.5m graduations, line reels, plastic carrying case, and instructions. Catalogue No Description EN26-156 Water Sampler Field Kit Combined Water Sampling & Measurement Kit The Combined Water Sampling and Measurement Kit is ideal for collecting water samples, bottom sediment samples, plankton samples, measuring turbidity, temperature and colour. Lightweight and compact for easy transport and simple to operate without extensive training. EN26-158 The kit is supplied complete with a Dissolved Oxygen water sample bottle, a bottom sampling dredge, a secchi disc, a sounding lead and calibrated line, a plankton net, a colour scale, and armoured thermometer (-5˚C to 50˚C in 0.5˚ graduations). All packed in a 350mm x 180mm foam-lined carrying case. Catalogue No Description EN26-158 Combined Water Sampling & Measurment Kit Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Description Toxic Gas Detection Catalogue No Meteorology Van Dorn Water Sampler Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 64 EN26-160 EN26-166 EN26-166 Tube Water Samplers Catalogue No Description EN26-160 Water sampler, stainless steel, 250ml, 32mm o.d. 20m fibre tape EN26-162 Water sampler, stainless steel, 1000ml, 45mm o.d EN26-164 Rope with hook eye for use with EN26-162 Stainless Steel Bacon Sampler Used to collect liquid samples from the top, bottom, or any intermediate level of storage tanks, tank cars, ponds, lagoons, and wells. A suspension cable (not included) may be used to lower the sampler to the desired depth. A second cable attached to the plunger assembly is pulled, allowing the reservoir chamber to fill. Releasing the cable allows the plunger to seal, holding the sample inside. Sampler is 63mm dia. X 280mm and holds 500 ml. Catalogue No Description EN26-166 Bacon Sampler, stainless steel, capacity 500ml EN26-168 Standard Heavy Puty Hand Reel made from P.P. EN26-169 Cable - PTFE coated stainless. 25m Water Sampling Pump Ideal for removing samples from shallow wells and surface water sources, including lakes, ponds, and holding pools. The water sampler is lightweight, rugged, easy to use, weather resistant, and requires minimal maintenance. Designed to take a manual sample, it also has the ability to backflush the sample hose once a sample has been taken. To provide high sample integrity, the water sample never comes in contact with any water sampler components other than the norprene and polyethylene tubing. The tubing is easy to clean and replace. To avoid cross-contamination or lengthy decontamination procedures, simply change the inexpensive tubing between samples. EN26-170 Includes a 3m power cord that can be attached to a 12V (car battery) power source. Specification Flow Rate 1000 ml per minute at 1.2m head Maximuim Lift 6.7m Pump Tube Norprene 6mm ID Sample Hose 4.6 m nylon reinforced polyethylene tubing with intake strainer Enclosure Expanded UV protected PVC Dimensions, cm / Weight, kg 23 x 19 x 11.5 / 2.7 Catalogue No Description EN26-170 Water Sampling Peristaltic Pump, includes tubing and 3m power cord EN26-172 Polyethylene Tubing (Per M) Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Hydrology & Groundwater 65 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Hydrology & Groundwater EN26-174 The Automatic Water Sampler is designed specifically to meet the sampling requirements for industrial discharges into sewers, rivers and streams. The sampler takes a ‘time weighted composite sample in a 10 litre bottle, to meet wastewater sampling guidelines The instrument can be easily set up near rivers and streams and also be suspended in a manhole for sewer sampling. • Simple to operate no programming required. • Timed and external flow pulsed composite samples. • Adjustable and repeatable sample volume. • Re-chargeable battery or AC powered. • lightweight and easy to carry. • Peristaltic pump prevents sample contamination. Specification 25ml to 600ml as set by user Operating Temperature 0-70˚C Materials Expanded UV protected by PVC Enclosure Bottle 10 litre polyethylene Flow Rate 1000ml per minute at 1.2m head Toxic Gas Detection Type Meteorology Sample Size Composite Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Automatic Water Sampler Peristaltic 6.7m Logic Timer / Controller CMOS solid state Sample Hose One 4.5m nylon reinforced 6mm ID polyethylene flexible tubing sections with intake strainer. Hose may be extended as required, using standard 6mm tubing and fittings Battery Life Battery will power sampler for a minimum of four months inc: five 24hr storm events before recharge required. Re-chargeable 5 AH gel Cell battery Dimensions, mm 230 x 430 x 560 Weight, kg 10 Catalogue No Description EN26-174 Automatic Water Sampler; supplied complete with a rugged rainproof lockable carrying case, 10 litre polyethylene sample bottle for composite sample,one peristaltic sampling pump, a control panel enclosed logic timer / controller, one 4.5m sample pickup hose with removable debris strainer, rechargeable battery and a battery charger. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Maximum Lift Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 66 Soil / Sediment Sampling & Analysis Soil that is contaminated contains substances that are actually or potentially hazardous to health or the environment. Current or previous industrial production can lead to land becoming contaminated by human activities such as mining, industry, chemical and oil spills and waste disposal. Contamination can also occur naturally as result of the geology of the area, or through agricultural use. Contaminated sediment in water bodies has emerged as a major ecological and human health issue and can be associated with acute and chronic effects on aquatic life. Sediments also constitute a major source of persistent bio-accumulative toxic chemicals which may pose threats to ecological and human health even after the pollutants cease to be released. Training Training Analysis Soil/ SediSoil / Soil Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sediment Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Sampling & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 67 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Soil Sampling Meteorology Soil Survey Kit A self contained soil survey kit comprising a comprehensive range of specialist equipment, that is designed to provide the soils specialist with all the equipment required for soil sampling, classification, basic chemical analysis, and soil compaction. Description EN32-102 Soil Survey Kit EN32-102 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Catalogue No Toxic Gas Detection • Hand held GPS • 50m measuring tape • Dutch and Riverside hand auger kits, 55mm and 75mm diameter, depth to 6m • Surface soil sampler • Soil colour charts • Soil texture kit • Range of soil sieves • Pocket soil Penetrometer • Soil analysis kit for NPK • Field handbook Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 68 Hand Auger Kits Driving Handle A comprehensive set for augering all types of soil down to a depth of 8-10 metres. These kits are specifically designed for use in soil research studies and are made to a high standard to ensure a long service life. Clip-on connection: The advantage of the clip-on connection is that it is very fast with little weight. The clip-on connection is strong, rigid and long lasting Cliip on rod Coupling Hand Auger Kit consisting of: • 6 x 1 metre clip-on rods • 1 x Driving Handle • 2 x Dutch Hand Augers S/L (55mm and 75mm diameter) • 7 x Slide Tubes for clip-on rods • 1 x Short tube for clip-on rods • 1 x Solid clip-on adapter for driving handle Screw thread connection: This connection is based on male and female thread on the parts to be coupled. The use of tapered threads for connection allows you to simply hand tighten the connection to create a rigid construction. Hand Auger Kit consisting of: • 6 x 1 metre Auger rods • 1 x Driving Handle • 2 x Dutch Hand Augers S/L (55mm and 75mm diameter) • 5 x Couplings Catalogue No Description EN32-104 Hand Auger Kit: depth 6m, 55 and 75 mm dia.Clip-on EN32-106 Hand Auger Kit: depth 6m, 55 and 75 mm dia. Screw thread Riverside Hand Augers Dutch Hand Auger A range of riverside hand augers designed for soil investigations and explorations. The design is very suitable for augering in hard, stiff soils, mixed with fine gravel both above and below the ground water level. The very sharp extremities of the auger bits point at an angle downwards, thus enabling the auger to pass through soil with minimal difficulty. The augers are plated against corrosion to ensure a long life. Catalogue No Description EN32-108 Hand auger with handle and T-piece, 80mm dia. x 1m long EN32-110 Hand auger with handle and T-piece, 100mm dia. x 1m long EN32-112 Hand auger with handle and T-piece, 150mm dia. x 1m long EN32-114 Extension Rod, 1m length Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 69 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis EN32-116 Used to obtain field samples of compacted ground or undisturbed soils, in order for an evaluation of density compaction at the ground surface to be undertaken. The set consists of a drop hammer which slides on the drive rod and falls on the drive head where the sampling tube is held. Catalogue No Description EN32-116 Surface soil sampler with sampling tube 73mm diam. 5kg drop hammer EN32-118 Surface soil sampler with sampling tube 100mm diam. 10kg drop hammer EN32-120 Sampling tube, 73mm diameter EN32-122 Sampling tube, 100mm diameter Soil Sampler Description EN32-124 Soil Sampler, T-handle with extension rod, 38mm dia. 900mm long EN32-126 Spare stainless steel sample tube, diameter 38 x 230mm EN32-128 Hand extruder used to extract specimens from the sample tube Toxic Gas Detection Catalogue No EN32-124 Soil Prospecting Kit Catalogue No Description EN32-130 Soil Prospecting Kit • Clay Core Tube • Core Tube Adaptor • Spiral Auger Tool • Lifting Tool • Prospecting Hammer • Hammer and Tommy Bar EN32-130 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring A complete set of soil prospecting equipment contained within a tough, durable and fully portable carrying case make this the ideal kit for soil prospecting applications in field studies. Maximum depth of 15 metres, subject to soil type for sample sizes of 25mm diameter. The kit comprises the following items: • 10 x 1 metre long Boring Rods • 2 x Driving Points • 12 x Couplings • Driving Head • Core Tube • Clearing Rod • 2 x Wrenches Meteorology Used to obtain undisturbed soil samples of diameter 38mm. The set consists of a T-handle with a 900mm extension rod, and a stainless steel tube, diameter of 38 x 230mm. The unit has a total weight of 7kg. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Surface Soil Sampler / Core Cutter Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 70 EN32-132 Soil Recovery Probes & Liners These top quality probes are made of high grade alloy tubing with chrome plating or durable stainless steel and can be used with or without liners. Each probe is supplied with a cross handle, 25mm dia x 300mm long plastic liner, and two end caps. Catalogue No Description EN32-132 Soil Recovery Probe and liner, 28mm dia EN32-134 Plastic Liner for Soil Recovery Probe, 25mm dia x 300mm EN32-136 Plastic End Caps for liners, 25mm dia (pkt of 100) Soil Colour Chart EN32-138 The Munsell Soil Chart is an affordable way to evaluate the type of soil that is present in a given area, the book is set up to allow users to make soil colour evaluations in the field quickly and easily. Practitioners from a wide range of professions can share reliable and consistent information about the colour of soils at a particular site with collagues anywhere around the world. Catalogue No Description EN32-138 Soil colour chart. Complete with supplementary tropical soil charts Environmental Soil Sampling Kit These kits are used for sampling in soils where there is potential for contamination below the ground surface. They use stainless steel components that allow for easy decontamination. Samples can be collected, prepared, and submitted for appropriate laboratory analysis. Includes: Regular, sand and mud augers, cross handle, split soil core sampler, slide hammer, three 1meter extensions, plastic liner, plastic end caps, wrenches, and cleaning brush in a rugged, foam-padded hard-sided deluxe carrying case with handles and wheels, 25 plastic liners, 50 plastic end caps, 50 fluoropolymer swatches for enhanced core sealing and a stainless steel scoop. Catalogue No Description EN32-140 Environmental Soil Sampling Kit EN32-142 Replacement Plastic Liner, 50mm dia x 150mm long EN32-144 Replacement Plastic End Cap for 50mm dia liner EN32-140 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 71 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis EN32-146 Soil texture refers to the proportionate distribution of the different sizes of mineral particles within a soil. Particles are grouped according to their size into what are called ‘size separates’ (clay, silt, and sand). Soil separates are a group of mineral particles that fit within definitive size limits expressed as diameter in millimetres. Included in this set, are three calibrated conical tubes with a stand, in addition to dispersing reagent and flocculating reagent that work together to speed settling of finely divided particles. Instructions explain method for breaking down soil samples into sand, silt and clay fractions. “A Study of Soil Science” provides background information on weathering and its relationship to soil formation. Provides for 50 tests. Catalogue No Description EN32-146 Soil texture kit. EN32-148 Soil texture kit refill pack. Provides reagents for 50 tests EN32-150 Catalogue No Description EN32-150 Agricultural soil sieve set EN32-152 Supplied as a complete set comprising of a broad range of sieve sizes with a lid and pan. 10 no sieves in the set with aperature sizes 2mm, 900mic, 600mic, 400mic, 250mic, 200mic, 140mic, 125mic, 100mic, 63mic. Pan diameter 100mm, pan height 45mm, body height 45mm. Catalogue No Description EN32-152 Set of 10 soil sieves Soil Sampling Bags A pack of 500 plastic bags that are used for the submission of samples for analytical assessment. The bags have a wire closure designed for sampling of soils and other materials. Specification Dimensions, mm 75 x 125 Pack quantity 500 bags Catalogue No Description EN32-154 Sampling Bags (pack of 500) Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Soil Sieve Set Toxic Gas Detection Soil sieve set providing a fast and effective means for the coarser components to be separated from a dry sample in order for preliminary analysis to be undertaken on site. The Alloy nesting sieves are 125mm in diameter and have round hole openings of sizes 0.5mm, 1mm, 2mm, 3mm and 5mm diameter. With lid and receiver, weight 4kg. Meteorology Agricultural Soil Set Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Soil Texture Kit Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 72 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 73 Sediment Sampling EN32-156 Sludge & Sediment Sampler Kit This manually-driven, end-filling multi stage sampler is used for discrete interval sludge and sediment sampling in rivers, lakes, wetlands, and estuaries. Complete kit contains a multi-stage sludge sampler, multi-stage sludge core tip, 30cm multi-stage core sampler base, three 30cm multi-stage core sampler sections, three 120cm extensions, plastic liner, plastic end caps, 50mm soil core catcher, universal slip wrench, two crescent wrenches, S / S cross handle, slide hammer, and the deluxe carrying case. Catalogue No Description EN32-156 Sludge and Sediment Sampler Kit, as described EN32-158 Replacement Plastic Liner, 50mm dia, x 30cm long EN32-160 Replacement Plastic Liner, 50mm dia, x 60cm long EN32-162 Replacement Plastic Liner, 50mm dia, x 90cm long EN32-164 Replacement Plastic Liner, 50mm dia, x 120cm long EN32-166 Plastic End Caps for liners, 50mm dia EN32-168 Hand Held Sludge & Sediment Sampler This sampler has been specially designed to take samples of sediment and sludge in rivers, wells, tanks, and shallow lakes etc. • Simple to use • Capacity of approx 250ml • Auto snaps shut on contact with the sediment • Spring loaded mechanism • Use with the telescopic pole that extends up to 4.5m Catalogue No Description EN32-168 Hand Held Sludge and Sediment Sampler, 250ml cap with 4.5m telescopic rod. EN32-169 Hand Held Sludge and Sediment Sampler extension rod length 4.5m www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis EN32-170 The Van Veen Bottom Sampler takes samples of sand or silt from river beds and lakes. The sampler is lowered with the bucket jaws open, it is then retrieved and raised to the surface by applying tension to the line which closes the two buckets. Specification Material Stainless steel Sampling area, cm sq 250 Weight, kg 5 Catalogue No Description EN32-170 Van Veen Bottom Sampler; supplied complete with bridles EN32-172 The Elkman Bottom Sampler is used for obtaining samples of sediments from river beds, lakes and estuaries. The sampler is designed with hinged upper doors which swing open when being lowered through the water A stainless steel messenger is dropped down the line to close the dredge preventing washout of the sample. Stainless steel Sampling area, cm 20 x 20 Weight, kg 10 Catalogue No Description EN32-172 Elkman Bottom Sampler Sediment Core Sampler Sediment Core Sampler collects samples from the bottom of rivers and lakes Core samples of 50mm diameter can be obtained from depths of up to 125m using an extension tube for retrieving samples in shallow water and a rope in deep water. Specification EN32-174 Material Stainless steel Sampling area, cm 20 x 20 Weight, kg 10 Catalogue No Description EN32-174 Sediment Core Sampler Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Material Toxic Gas Detection Specification Meteorology Elkman Bottom Sampler Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Van Veen Bottom Sampler Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 74 EN32-176 Surber Sampler The Surber Sampler is used for sampling organisms in streams and shallow rivers. Positioned with the 1000µm net down stream, the natural flow of water causes the bag to remain open. Invertebrates are then collected into the fine mesh net. When the open bottom frame is seated in pebbles on the stream bed and detritus within the stream bed is disturbed, then concealed organisms are swept into the net by the current of the water. Specification EN32-178 Sampling area, mm 305 x 305 Weight, kg 3.2 Catalogue No Description EN32-176 Surber Sampler Hand Net The Hand net is light and easy to use, and has been designed to overcome problems such as warping and breaking. The frame is attached to a wooden handle. Specification Material EN32-180 Wooden handle, aluminum frame, Polyester netting Width of frame, mm 250 Weight, kg 1.1 Catalogue No Description EN32-178 Hand Net Plankton Nets The Plankton Net is made from a strong nylon netting for durability and accuracy with a tough nylon collar. The net is supplied complete with a brass frame and a 0.3mm PVC filter. Includes a mini dolphin net / bottle adaptor with 125ml sample bottle. Available in 3 sizes. Specification Material Nylon Aperature Size, mm 0.1 Net Diameter, mm 300 Overall Length, mm 900 Catalogue No Description EN32-180 Plankton Net 80 microns EN32-182 Plankton Net 156 microns EN32-184 Plankton Net 363 microns Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 75 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis EN32-186 This easy-to-use system provides rapid and accurate readings of suspended solids, sludge blanket level, and turbidity. The robust IP65 enclosure incorporates a security strap and protective case to prevent accidental dropping, impact damage and abrasion of the display surface. • Up to 10 different customer programmed calibrations allow for monitoring of multiple sites with one monitor • Quick and easy measurement operations Specification Response time 0.5 seconds Accuracy ±5% FSD on real sample Repeatability ±1% FSD on real sample Measurement Principle Infrared Light Attenuation Wavelength 880 nm Pressure Rating 10mWC Flow rate Not affected by flow rate Maximum range 0-20,000 mg/l Minimum range 0-50 mg/l Unites of measurement Mg/l, g/l, ppm, NTU, FTU, %SS, User Defined Operating temperature -20 to 60°C Power Universal charger 90-264 VAC, UK, US, and EU plugs. Sensor dimensions (DxL) 45mm x 155mm Meter+Sensor weight, kg 1.2 Kit dimensions, cm 45 x 15 x 30 Catalogue No Description EN32-186 Portable Suspended Solids Meter comprising Meter and Sensor with 5m cable housed in a protective carry case with strap. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring • Compact robust design housed in a protective carry bag Toxic Gas Detection The accuracy and convenience of this system make it ideal for regular checking of suspended solids levels to process or legislated requirements in activated sludge plants, final effluent outfalls, treatment plant inlets, streams and rivers and as a secondary standard to check other on-line and portable instruments. Meteorology The unit includes capability for up to ten customer programmed user profiles, each defined by site specific calibrations to cater for differences in the effluents being monitored. A retrospective adjustment to the calibration for each site is also possible via a unique menu facility that enables a specific sensor output to be stored in memory at the same time as a liquid sample is taken. The gravimetric analysis of the suspended solids level in the sample is then returned to the monitor as the final calibration figure. Further site calibration enhancement is afforded by the ten-point look up table that allows the monitor to accurately measure suspended solids in vast majority of applications. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Suspended Solids Meter Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 76 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 77 Soil Moisture & Analysis EN32-188 Soil Moisture Meter Solid state, electrical resistance sensor provides accurate readings from 0 to 200 centibars, covering the entire soil moisture range required in irrigated agriculture. In operation, soil moisture is constantly being absorbed or released from the sensor. Resistance is read by the hand-held digital meter and features soil temperature compensation. Temperature scale can be adjusted to use either °F or °C scales. Simple to use, just bury the sensor to desired depth, connect alligator clips located on meter to the sensor, and view results on digital display. Sensor is manufactured from non-corrosive parts and measures 22mm x 82mm. Accuracy: ±3%. Catalogue No Description EN32-188 Digital soil moisture meter and sensor with 1.5m cable EN32-190 Replacement sensor Digital Soil Moisture, Temperature, and Salinity Probes EN32-192 Each meter is highly accurate, displays results within seconds, may be used in a variety of soils, and is unaffected by temperature, pH, dissolved salts, or metallic ions. Simply insert probe at least 15cm into reasonably soft, moist area and press appropriate test button. Results appear quickly. Rapidly perform multiple tests at various depths and locations. Operating temperature: 4ºC to 65ºC. Power: 9V battery (included). Battery life (approx.): 3 months. Probe length: 76cm. Overall length: 91cm. Weight (approx.): 2.5kg Catalogue No Soil Moisture Soil Temperature Salinity EN32-192 EN32-194 EN32-196 Range 0 to 100% 0 to 100% 0 to 100% Accuracy ±2% ±2% ±2% Response Time 3 sec 3 sec 3 sec Range 4ºC to 65ºC 4ºC to 65ºC Accuracy ±1.5ºC ±1.5ºC Response Time 60 sec 60 sec Range 0 to 100 cS/m* Accuracy in Water ±2 cS/m* Accuracy in Soil ±10 cS/m* Catalogue No Description EN32-192 Digital Soil Moisture Probe. Displays soil moisture percentage EN32-194 Digital Soil Moisture and Temperature Meter. Displays both soil moisture percentage and soil temperature EN32-196 Digital Soil Moisture, Temperature and Salinity Meter. Displays soil moisture percentage, soil temperature, and soil salinity www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis EN32-198 This pocket meter is designed to directly measure soil conductivity and temperature. With a temperature sensor incorporated into the penetration probe, readings are automatically temperature compensated. Conductivity range can be calibrated in an aqueous solution with a single calibration point. Specification EC: 0.00 to 4.00 mS/cm; Temperature: 0.0 to 50.0˚C Resolution EC: 0.01mS/cm; Temperature: 0.1˚C Accuracy EC: +/-0.05 mS/cm (0.00 to 2.00mS/cm), +/-0.30 mS/cm (2.00 to 4.00 mS/cm); Temperature: +/-1˚C Calibration Manual, 1point Temperature compensation Automatic Dimensions, mm 163 x 40 x 26 Weight, g 100 Catalogue No Description Pocket Conductivity and Temperature Meter, supplied complete with penetration probe, batteries and instructions. It is highly recommended a 1413uS solution is used to calibrate the meter (sold separately). EN32-198 1413 µs/cm (1.4 mS/cm) calibration solution, 500 mL EN32-202 1413 µs/cm (1.4 mS/cm) calibration solution, 20 mL, 25 sachets EN32-204 Direct Soil pH Measurement Kit Specification -2.00 to 16.00 pH -5.0 to 105.0 °c 0.01 pH 0.1 °c ±0.02 pH ±0.5 °c up to 60 °c; ±1 °c outside Range Resolution Accuracy (@20 °c) Temperature Compensation pH Calibration Electrode (included) Automatic Automatic 1 0r 2 point calibration with 2 sets of memorized buffers (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18) pre amplified pH / temperature electrode with DIN connector and 1m cable Battery Type (3) 1.2V AAA, life: 1500 hrs Environment 0 to 50 ºC RH max. 100% Dimensions, mm 150 x 58 x 29 205 Weight, g Description EN32-204 Direct Soil pH Measurement Kit EN32-206 Replacement pH electrode for soil measurement, with internal temperature sensor, DIN connector on a 1m cable EN32-208 Refill pack containing buffers and cleaning solutions Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Training Catalogue No Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring The kit has been designed to measure pH directly in soil accurately and quickly. Testing both the pH of soil directly or after preperation of a diluted sample. The electrode has a conical, rugged tip and can be directly inserted in moist or soft soil. Use the specially made soil preparation solution for higher degrees of accuracy, or for stony ground where the electrode may be damaged. This solution is included to help you measure pH more precisely by diluting the soil sample. In order to measure the pH directly, the kit includes a plastic auger to perforate the ground. This hand held product has a large, multi-level LCD which displays the primary reading, temperature and calibration guides simultaneously. Complete kit includes meter, pH electrode, soil auger, soil preparation solution, starter set of calibration solution sachets, 100ml plastic beaker, batteries, instructions and carrying case. Toxic Gas Detection EN32-200 Meteorology Range Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Soil Conductivity & Temperature Meter 78 EN32-210 Soil Analysis Kit This comprehensive soil analysis kit is designed for use by farmers, horticulturalists, agronomists, scientists and consultants in the field or laboratory and will enable a range of tests to be carried out at a fraction of the cost of full scale laboratory analysis. Increased accuracy is ensured by the use of digital meters and a photometer which, together with extraction and reagent tablets for 50 tests, will measure the following parameters: pH, conductivity, nitrate nitrogen, phosphate phosphorus, potassium, sulphate, iron, manganese, copper, ammonia nitrogen, chloride, calcium, and magnesium - supplied in carrying case. EN32-300 Catalogue No Description EN32-210 Soil Analysis Kit including accessory pack EN32-212 Refill soil extraction and reagent pack for Soil Analysis Kit, 50 tests HM4000 Metalyser Heavy Metals Soils Analyser Portable Analyser, incorporating innovative extraction and digestion equipment, for easy detection of heavy metals in soil samples. • Rapid in-field analysis • Precise results to ppb levels • Voltammetric technique • User-friendly extraction and analysis • Rugged, waterproof carrying case • Consumables for 50 tests included Measures the following parameters Catalogue No Description EN32-300 Metalyser HM4000 Instrument, Sonde with 2m cable, electrodes, 1 reference electrode, 1 counter electrode, beakers, mains charger, car charger, USB cable, buffers, standards and conditioning solutions, soil extraction kit, Metaware software and waterproof carry case. Note: For details of the full Metalyser range, please refer to pages 15 to 18. Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 79 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis On site screening of heavy elements in soil provides remarkable savings on laboratory costs. This portable analyser can be used in the most demanding locations and provides fast and reliable analysis of all the heavy elements of interest in soils. The results are available instantly so decisions can be made on site. Pre-sorted contaminated soil enables you to minimize remediation costs and landfill fees. EN32-350 Toxic Gas Detection Air particles on filters, wipe test swabs, equipment surfaces, coatings, vegetation etc can also be analysed. Meteorology • Preliminary screening reduces the amount of actual laboratory analysis needed – No need to wait for laboratory results! • Sorting the contaminated soil means great savings in landfill fees decisions can be made in minutes instead of days • Preliminary analysis of unknown samples at the beginning of the remediation process enables remarkable cost savings • Instantly locate and identify polluting elements and define the extremities of ‘hotspots’ • Analysis can be done directly from the ground or from samples in sample bags or cups • Laboratory quality analytical data is obtained by measuring prepared samples using the optional benchtop stand which quickly converts the handheld analyser into a laboratory unit. • Samples can be in the form of soil, rock, dirt, humus, sand, powder, liquid etc. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable XRF Analyser for Screening Heavy Metals in Soils Specification Pb, As, Cr, Cu, Zn, Ni, Cd, Co, Se, Mo, Hg, Sb, Ag, Ba etc Measurement time 30 -120 second Element range K to U Low detection limits Can typically detect 5 – 30 ppm concentration with a 120s measurement time. Measures all 26 elements defined in EPA6200 Real time averaging Calculates averages of 2 – 50 measurements and saves individual results and averaged results IP Rating IP54 Weight, Kg 1.8 Catalogu.e No Description EN32-350 Portable XRF Analyser for Screening Heavy Metals in Soils, supplied complete with battery charger and carrying case EN32-352 Bench Top Stand Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Heavy element analysis for Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 80 Hydrocarbons In Soils EN32-400 Soil Test Kit for Total Petroleum Hydrocarbons This kit will determine total petroleum hydrocarbons across a wide range of soil types and petroleum products, and is ideal for use in the field. The system enables the user to run 10 tests concurrently, providing the potential to run 25 tests in one hour. The kit can also be calibrated to measure quantitative amounts of specific petroleum products including: BTEX, PAH, diesel fuel, leaded and unleaded gasoline, brent crude, and lubricating oil. Self-filling ampoules minimise operator exposure to the reagents and dramatically reduce the volume of solvent needed for extraction, making the kit safe and environmentally friendly. Ranges (Expected dynamic range of the test in soil sample matrix). Specification Unleaded Gasoline 80-600 mg/kg BTEX 16-140 mg/kg Diesel 60-400 mg/kg Leaded Gasoline 80-520 mg/kg Brent Crude 40-400 mg/kg Lube Oil 120-1000 mg/kg PAH (18 component mixture) 8-60 mg/kg Both the Starter and Reagents Kits are required for operation. Catalogue No Description EN32-400 Starter Kit includes Photometer, Electronic Balance, Timer, PTH Tube Plug/Snapper, Tip Breaking Tool, Batteries, and instructions. EN32-402 Reagents for conducting 16 tests, reagent blank ampoule and MSDS. Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 81 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis EN32-404 The Soil Gas Vapour Probe Kit system allows for monitoring or sampling hydrocarbon spill sites, underground storage tanks and pipelines. The Probe is used for sampling soil vapours to a depth of 3.5m, and has been designed specifically for placement of devices used to recover soil gas samples. Catalogue No Description EN32-404 Soil Gas Vapour Probe Kit with rotary hammer drill, 4 x 90cm extension rods, tip drive adapter, extension drive and hammer drill adapter, 10 x GVP tips, 38mm diameter cement bit, hand vacuum pump, 75m roll of Teflon tubing, manual hammer attachment, removal jack, tile probe base, 3 x tile probe extensions, with carrying case and instructional video. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Soil Gas Vapour Probe Kit Meteorology Toxic Gas Detection EN32-406 This Portable VOC Detector is the most reliable handheld Volatile Organic Compound (VOC) monitor on the market. Its Photoionization Detector’s (PID) range of 0 to 5,000 ppm makes it an ideal instrument for applications ranging from environmental to construction and in particular for use with the Soil Gas Vapour Probe Kit. The patented sensor provides the following unique features: • Big graphic display for easy overview of concentration • Range up to 5,000 ppm • Integrated flashlight for better visibility in low light • Multi-language support with 12 languages encoded • Rugged housing withstands use in harsh environments IP-65 design • Auto-cleaning technology • Tough, flexible inlet Flexi-Probe™ • Loud, 95 dB audible alarm • Bright red flashing visible alarm • Soft leather carrying case • Size (LxWxH) 25.5 x 7.6 x 6.4 cm, 738 grams Catalogue No Description EN32-406 Portable VOC Detector EN32-408 Portable VOC Detector accessories kit, comprising 5 x litres, Organic Vapor Zeroing Kit, Gas Outlet Adapter, Hard carring case. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Portable VOC Detector Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 82 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Soil/ Sediment Sampling & Analysis 83 EN32-416 Portable Landfill Gas Monitor This landfill & contaminated land gas analyser is designed to meet landfill monitoring protocols for the following range of gas measurements Methane(CH4), Carbon Dioxide (CO2), Oxygen(O2), Hydrogen Sulphide(H2S), Carbon Monoxide (CO) The instrument is ideally suited to landfill sites, gas extraction, site investigations, and biogas applications. • CH4, CO2 and O2 • Additional sensors H2S, CO • Simultaneous display of all gases • Additional gases including H2S up to 10000ppm and H2 compensated CO • Optional ATEX certified anemometer • Additional Gas Analyser Manager software for data download • View calibration history on the analyser screen Specification By dual wavelength infrared sensor with reference channel By internal electrochemical sensor CO2 and CH4 Gases measured O2 CO (hydrogen compensated), H2S, NH3 and H2 (optional) By internal electrochemical sensor Oxygen cell life Approximately 3 years in air Suitable for sampling applications - not for continuous use Range CH4 CO2 O2 CO H2S 0-100% 0-100% 0-25% 0-2,000ppm 0-50ppm up to 0-10,000ppm Typical accuracy after calibration CH4 CO2 O2 CO CO (H2)* H2S 0-70% 0-60% 0-25% 0-500ppm 0-2,000ppm 0-50ppm 0-200ppm 0-500ppm 0-1,000ppm 0-5,000ppm 0-10,000ppm Response time, T90 CH4 CO2 O2 CO H2S ≤ 10 seconds ≤ 10 seconds ≤ 20 seconds ≤ 30 seconds ≤ 30 seconds Hydrogen (Gas Analyser software required) ±0.5% (vol) ±0.5% (vol) ±1.0% (vol) ± 2.0% FS ± 1.0% FS ± 1.5% FS ± 2.0% FS ± 2.0% FS ± 2.0% FS ± 2.0% FS ± 5.0% FS 70-100% 60-100% ±1.5% (vol) Compensated for interference from up to 2,000ppm hydrogen. Hydrogen cross gas effect on CO approximately 1%. Pump Flow 550 ml / min typically Flow fail point -200 mbar vacuum - user settable Maximum vacuum restart -375 mbar approximately with flow rate of approximately 80ml/ min Power Supply Battery type Rechargeable nickel metal hydride battery pack (not user replaceable) Battery life Typical use 8 hours from fully charged Battery charger Separate intelligent battery charger powered from mains supply (100-240V) Charge time Approximately 3 hours from complete discharge Catalogue No Description EN32-416 Portable Landfill Gas Monitor EN32-418 Gas Analyser Software EN32-420 Temperature Probe EN32-422 Anemometer Probe EN32-424 Extra sensor H2S EN32-426 Extra sensor CO www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil/ Sediment Sampling & Analysis Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring This contains products made by leading manufacturers certified to ISO 9001 quality standard, supplied and shipped to your nominated destination. Toxic Gas Detection A comprehensive range of laboratory equipment can be found in our Wagtech Projects General Laboratory Equipment Catalogue. Meteorology THE LAB CAT Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 84 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas Meteorology ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Meteorology 85 Meteorology A range of conventional and high technology instruments for measuring and recording weather data www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Meteorology Automatic Weather Station Accuracy -20 to +70°C 0.2°C at 25°C Relative Humidity 0 to 100% (-20 to 70°C) +/- 2% max, typical 1% or better Rain Gauge Sensitivity 0.2mm / tip Pyranometer 400 to 1100nm +/- 5% max, typical 3% or better Anemometer > 75m/s +/- 2%, +0.1m/s Wind Direction Sensor > 75m/s +/- 2% Catalogue No Description EN44-102 Automatic Weather Station comprises of multi-channel datalogger with memory capacity for approximately 27,000 readings Hydrological Monitoring Station The Hydrological Station has been designed for use by farmers, hydrologists, and researchers to collect data on local hydrological conditions. As with the other monitoring stations, this is a lightweight unit that can easily be moved from site to site if required. The station comprises sensors for measuring wind speed, wind direction, rainfall and water level (0 to 10 metres). Supplied complete with datalogger, 2 metre frame, solar charger unit, re-chargeable battery pack, and computer software. Catalogue No Description EN44-104 Hydrological Monitoring Station Windspeed and Direction Monitor Windspeed and Direction monitor comprising of a 2 channel datalogger and wind speed and wind direction sensor mounted on a 2 metre mast. Catalogue No Description EN44-106 Windspeed and Direction Monitor Rain Monitoring System Catalogue No Description EN44-108 Rain Monitoring System Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Training Rain Monitoring System comprising Data Logger, Batteries, Standard Software, RS232 Data Lead, Rain Gauge, and Base levelling Plate. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Range Air Temperature Toxic Gas Detection Sensors Meteorology Comprising of 6 sensors for measuring all the key weather parameters; wind speed, wind direction, air temperature, relative humidity, rainfall and solar radiation. An 8 channel datalogger is used to collect and store the data which can then be retrieved using either the 2 metre RS 232 cable and a laptop pc on site, or alternatively by using one of the remote connection options listed on page 88. The unit is powered by internal alkaline batteries which, under normal use, will last from 4 to 6 months. Supplied complete with data transfer software. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Automatic Weather Stations 86 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Meteorology 87 Sensors Our standard systems use the most common sensors. However, a wide range of additional sensors are available for use with the weather station. These include light sensors such as PAR quantum, UVA, UVB, as well as tensiometers, soil moisture and water level. Please contact Wagtech Projects if you require a non-standard weather station using these sensors. Wind Direction & Wind Speed - EN44-110 Rainfall - EN44-114 Range 0 to 360° Range 0.2mm per tip Accuracy Accuracy ±5% (24 to 36 mm/hr) Maximum wind speed ±2° obtainable in steady winds over 5 m/s >75 m/s Range (speed) 0 to 75m/s Range -20 to + 80°C Accuracy (speed) 2% ±0.1 m/s Accuracy ±0.2°C at 0 to 60°C Soil Temperature - EN44-116 Air Temperature & Relative Humidity - EN44-112 Solar Radiation - EN44-118 Range Range 400 to 1100 nm Accuracy ±5% traceable to UK Met Office Accuracy -20 to +70°C ±0.2°C between 0 and 60°C Range 0 to 100% Relative Humidity Air Pressure - EN44-120 Accuracy ±2% Relative Humidity Range 500 to 1050 mbar Accuracy Absolute error at 20°C / 1000 mbar typically 0.5 mbar (Max. 1mbar) Error over 0-50°C typically 1.5 mbar (Max. 3.6 mbar) Masts Catalogue Number Description EN44-124 2m portable mast mounted on metal plate with guylines and pegs EN44-126 10m retractable mast with guylines, base and pegs Datalogger Specification Channels Maximum of 16 available Operating range -20°C to +70°C Housing Grey ABS with seal to IP65 Communications RS232C Power supply 6 x C-cell alkaline batteries. These will last approximately 4 to 6 months Memory capacity 1Mb RAM, total of up to 27000 readings Catalogue No Description EN44-128 8 channel datalogger includes batteries, data downloading software, RS232 data cable & USB / Serial converter EN44-130 16 channel datalogger includes batteries, data downloading software, RS232 data cable & USB / Serial converter Note: Software for Automatic Weather Stations see following page. www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Meteorology Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Communications and Computer Software* for Automatic Weather Stations The standard weather station is supplied with a 2m long RS232 communications cable and standard downloading software. A laptop computer is required to retrieve the data on site. Additional software is available to display the data, build graphs and wind roses etc, and to monitor the operation of up to 25 weather stations. Other options include: •Permanent cable link which is used with mains power supply, and the communications from base to AWS distance no more than 50m • Permanent cable link also uses the mains power supply and communication for distances up to 1km •GSM modem unit is available in order to enable communication with the station 24 hours a day using the local cell phone network Laptop computer EN44-134 Permanent cable link (with 25m cable) EN44-136 Permanent cable link (with 75m cable) EN44-138 GSM modem unit (requires solar power unit supply) EN44-140 Solar power supply, for use with GSM modem EN44-142 Deluxe software, for use with the standard datalogger to display the weather data, build graphs etc EN44-144 Deluxe Auto software, for use with up to 25 weather stations to monitor and download data automatically * Please contact us for alternative communications options. Toxic Gas Detection Description EN44-132 Meteorology Catalogue No Indoor / Outdoor Automatic Weather Station This wireless weather station provides accurate, reliable weather monitoring in a self-contained, easy-to-install system. The station gives you all the weather data you need for use by small farms, and in education. Sleek but tough; your outdoor sensor unit can be set up in minutes and starts sending data wirelessly to your console anywhere in your school, or business. Current weather conditions are displayed, including indoor and outdoor temperature, humidity, barometric pressure, wind speed and direction, dew point and rainfall. Also displayed are weather forecast icons, moon phase, sunrise / sunset times, graphing of weather trends, alarms and more. The station boasts the innovative Weather Centre button that displays additional data on weather variables for today and over the last 25 days. •Compact, self-contained and easy to install •Combines a rain gauge, temperature / relative humidity sensor, an anemometer and wind vane into one package • Transmits wirelessly up to 300 metres •Includes console Automatic Weather Station includes sensors for measuring wind speed, wind direction, air temperature, relative humidity, barometric pressure and rainfall, solar powered with lithium back up battery. Catalogue No Description EN44-146 Indoor / Outdoor Automatic Weather Station Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring EN44-146 Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 88 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Meteorology 89 EN44-148 Automatic Weather Station These Automatic Weather Stations are available in both wireless and cabled versions. Both include innovative integrated sensor unit, which combines a rain gauge, temperature and relative humidity sensors, anemometer and wind vane, 12 m anemometer cable, and solar panel. Electronic components are housed in a weather-resistant shelter. Console may be powered using the included AC-power adapter or with three C batteries (not included). Wireless range is up to 300 m outdoors, line of sight. Typical range through walls under most conditions is 60 to 120 m. •Forecasting, on-screen graphing and much more •Quick view icons show the forecast at a glance while a moving ticker-tape display gives details Specification EN44-152 Accuracy Wind Direction 360° ±3° Speed: 3 to 241 km/h ±5% Wind Chill: -92° to 60°C Humidity: Inside: 0% to 100% Outside: 0% to 100% ±2°C ±5% ±3% Barometer: 480 to 820 mm Hg ±1.3 mm Hg Temperature: Inside: 0 to 60°C Outside: -40° to 65.5°C ±0.5° C ±1° F, 0.5° C Rainfall: Daily: 0-6553 mm Accumulation: 0-6553 mm ±4% ±4% Time & Date: 12 or 24 Hour Clock, Time Alarm and Date Catalogue No Description EN44-148 Automatic Weather Station (Cabled) EN44-150 Automatic Weather Station (Wireless) GPS Receiver This GPS is a tough and rugged piece of equipment suited to all types of terrain. It has a highly-sensitive WAAS / EGNOS-enabled receiver which holds a GPS signal in the toughest conditions. It has a bright colour screen, barometric altimeter, electronic compass, microSD and automatic routing. • Power supply 2 x AA batteries • 256 colour screen TFT • USB compatible • Rugged and weater proof case • Water resistant to IEC-529, IPX7 standards • 25 Hours battery life • Store up to 50 routes, 1000 waypoints, 10,000 points and 20 saved tracks Specification Receiver 12 channel GPS Antenna Patch Acquisition time 0:15 - 0:45 Accuracy <15m Internal memory 24MB Number of waypoints 1000 Number of tracking plots 10000 Weight, g 156 Dimensions, mm 111 x 50 x 30 Catalogue No Description EN44-152 GPS receiver www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Meteorology Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Manual Weather Stations & Instruments Meteorology EN44-196 Specification Air Temperature Indoor Range: 0°C to 59.9°C Outdoor Range: -39.9°C to 59.9°C Reading: Indoor every 15 seconds / Outdoor every 4 seconds Calibration: Can be calibrated Temperature Resolution: 0.1°C Transmission Frequency: 868 MHz Memory: 24 hour Wireless transmission distance: 100m open field Time Radio controlled Display: 12 / 24 hours Time zone: +/- 9 hours Calendar with date / month Dimensions, mm Display: 136 (H) x 95 (W) x 19 (D) Transmitter: 128 (H) x 41 (W) x 19 (D) Battery Type: 4 × 1.5v AA battery (included) Life: Approx 12-18 months Catalogue No Description EN44-196 Digital Wireless Indoor / Outdoor Thermometer Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Digital thermometer with simultaneous display of both current indoor and outdoor air temperatures and the daily minimum and maximum. Can take up to 2 wireless receivers (1 included) and has a 3rd channel for a temperature probe (included). Radio controlled clock synchronised with the atomic signal so the time is always correct. Supplied with a pullout stand or can be wall mounted. Toxic Gas Detection Digital Wireless Indoor / Outdoor Thermometer Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 90 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Meteorology 91 Mercury Free Max / Min Thermometer EN44-198 EN44-200 Traditional Max-Min design with a non mercury filling. Press button reset. -40 to +50˚C Suitable for wall hanging. Catalogue No Description EN44-198 Mercury Free Max / Min Thermometer Max / Min Slimline Thermometer A simple low cost design with seperate resetting magnet. ˚C & ˚F. -40 to +50˚C Suitable for wall hanging. Catalogue No Description EN44-200 Max / Min Slimline Thermometer Electronic Max / Min Thermometer EN44-202 Simultaneous monitoring of two environments. The thermometer has 2 sensors & each sensor has its own readout. One sensor is inside the unit. The external sensor has a 3 metre connection lead. The Min / Max Memory operates independently for each sensor. Specification Range -50° to +70°C, (External Sensor) -10º to +50ºC, (Internal Sensor) EN44-204 Resolution 0.1°C Accuracy ±2°C Power 1 x 1.5V AA Battery (ALR-6) Dimensions, mm 135 x 75 x 18 Weight, g 117 Catalogue No Description EN44-202 Electronic Max / Min Thermometer Compact Thermo-Hygrometer A compact design for ease of use with an integrated vented sensor grill, which enables measurements to be taken within an air stream. Sensing is by a precision thermistor for temperature, and a resistive polymer sensor for humidity, giving fast and repeatale readings. • Measures ˚C or ˚F • 25mm Hi-Contrast LCD with Backlight • Data Hold freezes displayed measurements • Min / Max Memory since power on • Low Battery indication (flashing display) • Auto Power Off • Supplied with carry case & battery Specification Range Temperature Humidity -20°C to +60°C 5% to 100% RH Resolution 0.1°C 0.1% RH Accuracy ±2°C ±3.5% RH Power 1 x 9V PP3 Alkaline Battery (ALR-61) Dimensions 225 x 45 x 34mm Weight 200g Catalogue No Description EN44-204 Compact Thermo-Hygrometer www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Meteorology EN44-206 A high accuracy combined humidity & air temperature meter with wet bulb and dewpoint temperatures. Ideal for a wide range of industrial and laboratory applications. Suitable for single handed operation. • Dew Point & Wet Bulb temperatures displayed at the touch of a button • LCD dual display with backlight • Connected probe with 1.8m coiled cable • Data Hold freezes displayed measurements • Min / Max Memory for both temperature and humidity • Impact-resistant ABS case with rubber boot and flip-out desk stand Specification Humidity Dewpoint Wet Bulb -30° to 100°C 0 to 100% RH -30° to 100°C 0° to 80°C Resolution 0.1°C 0.1%RH 0.1°C 0.1° ±2%RH ±1.0°C ±1°C ±0.5°C 1 x 9V PP3 Alkaline Battery (ALR-61) Dimensions, mm 155 x 72 x 35 Weight, g 210 Catalogue No Description EN44-206 High Accuracy Thermo-Hygrometer, supplied with carry bag & strap, rubber boot and battery Wet & Dry Bulb Hygrometer-Complete Kit Toxic Gas Detection Accuracy Power Meteorology Temperature Range EN44-208 Specification -20 to 55˚C Graduations 0.5˚C Expected accuracy +/- 0.1˚C Medium Mercury Catalogue No Description EN44-208 Wet & Dry Bulb Hygrometer Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Consist of 2 Sheathed Pattern Ordinary Thermometers manufactured to BS692, meeting BMO requirements, 4 thermometer brackets for mounting them in screen, water reservoir with bracket, pack of 50 wicks and 10 round headed brass wood screws. Range Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis High Accuracy Thermo-Hygrometer Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 92 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Meteorology 93 EN44-210 Digital Temperature and Humidity Station Indoor & outdoor digital thermometer and humidity station, with simultaneous display of both temperature and humidity with minimum and maximum recordings for the day. Outdoor reading from wireless sensor, and indoor display unit supplied with pull out stand or can be wall mounted. Specification Temperature Humidity Time Dimensions Battery EN44-212 Indoor Range: –9.9°C to 69.9°C Outdoor Range: -29.9°C to 69.9°C Reading: Indoor every 10 seconds / Outdoor every 4 seconds Calibration: Can be calibrated Resolution: 0.1°C Transmission Frequency: 868 MHz Memory: 24 hour Wireless Transmission Range: 100m open field Indoor Range: 1% to 99%rh Outdoor Range: 1% to 99%rh Resolution: 1% Accuracy : +/- 3% Measure units: %rh Reading: Indoor every 20 seconds / Outdoor every 4 seconds Radio controlled Display: 12 or 24 hours Time zone: +/- 9 hours Calendar with date / month or day / date Manual setting Display: H 138 x W 106 x D 36mm Transmitter: H 160 x W 43 x D 23mm Type: 5 × 1.5v AA (included) Life: Approx 12-18 months Catalogue No Description EN44-210 Digital Temperature and Humidity Station Digital Wireless Indoor Outdoor Thermometer & Humidity Station Digital Indoor Outdoor Thermometer & Humidity Station Large display with simultaneous reading of both temperature and humidity. Temperature readings can be switched indoor or outdoor and from maximum to minimum readings at the press of a button. Alarm function on both temperature and humidity. Stand or wall mounting supplied complete with 2.8metres of cable for outside probe. Temperature range Indoor: 0 to 50ºC, Outdoor: -50 to +70ºC Dimensions: 98 x 74 x 17mm Catalogue No Description EN44-212 Wireless Temperature & Humidity Station Thermohygrograph EN44-214 The Thermohygrograph has cast brass side frames and base, mechanism machined and fabricated from high quality brass, polished and lacquered. Recording Section • Battery operated quartz clock with simple mechanism for changing rotation from daily to weekly. • Daily or weekly rotation selected by change gear provided. • Recording is effected by easily changed fibre tipped pen. Specification Humidity Temperature Range 0 to 100% 0 to 50˚C Accuracy ±3% between 20 & 80% ±5˚C Sensing Element Specially treated human hair Bi-metalic coil (corrosion protected) Catalogue No Description EN44-214 Thermohygrograph EN44-216 Pack of 100 daily charts EN44-218 Pack of 100 weekly charts EN44-220 Fibre Tipped Pen (Humidity-Red) EN44-222 Fibre Tipped Pen (Temp-Black) www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Meteorology EN44-224 Complete with 400 filter paper discs. Water reservoir graduated every 0.1ml. Weight 60g. Catalogue No Description EN44-224 Piche Evaporimeter EN44-226 Filter paper discs: packet of 400 EN44-228 Clip: for attaching filter paper discs EN44-230 Stand Hook Gauge Evaporimeter Supplied complete with, hook gauge, still-well and aluminuim pan. (supplied without floating thermometer) Specification EN44-240 Aluminium Pan 1220 dia x 254 high Weight, Kg 65 Meteorology Dimensions, mm Hook Gauge Graduated from 0 to 10mm, reads to 0.02mm Dimensions, mm nominal 215 high Weight, g 340 Toxic Gas Detection Micrometer Still Well Dimensions, mm nominal 50 dia x 215 high Weight, g 1.8 Floating Thermometer -30ºC to +50ºC x 0.5ºC Accuracy +/-1ºC Dimenisons, mm 340 x 140 x 60 Weight, g 310 Catalogue No Description EN44-232 Hook Gauge Evaporimeter EN44-234 Aluminium Pan EN44-236 Still-Well EN44-238 Hook Gauge EN44-240 Floating Thermometer EN44-232 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Range EN44-238 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Piche Evaporimeter Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 94 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Meteorology 95 EN44-242 Plastic Rain Gauge • Moulded from clear high quality SAN (Styrene Acrylonitrile). • Permanently embossed and accurate scale clearly calibrated in single millimetres from 1mm to 40mm. • Approx size: 200mm x 125mm Catalogue No Description EN44-242 Plastic Rain Gauge Copper Rain Gauge With 127mm diameter rim with inner can and measuring cylinder calibrated in mm. Weight 1.1Kg. Catalogue No Description EN44-244 Copper Rain Gauge EN44-248 Measuring Cylinder Splayed-base Rain Gauge EN44-244 Model constructed from copper with splayed base to provide extra stability, and a brass septum ring with a 127mm diameter. Supplied with inner can taper-base glass measure. Catalogue No Description EN44-250 Splayed-base Rain Gauge EN44-252 Taper-base glass measure Dines Tilting Siphon Rain Gauge EN44-254 The Tilting Siphon Rainfall Recorder is manufactured to British Met Office drawings. It produces a record of rainfall against time. The automatic tilting action ensures unlimited collecting capacity. It is frequently used in conjunction with a daily rain gauge to provide a permanent record of the start and end of rainfall, together with variations in intensity. The movement of a float in the collecting chamber causes a pen to mark a daily or weekly chart, which is viewed through the hinged front window. When 25mm of rain has fallen represented on the chart by a linear distance of 50mm - the pen is at the top of the chart and the chamber tilts and empties. The pen then returns to the bottom of the chart to start recording again. The Gauge is constructed from non-ferrous materials and supplied with a hand-wound clock. Catalogue No Description EN44-254 Dines Tilting Siphon Rain Gauge EN44-256 Daily charts: pack of 200 EN44-258 Fibre Tip pen Electronic Wireless Rain Gauge EN44-264 A wireless rain gauge with rainfall memory, outdoor temperature and digital clock. Current and accumulated rainfall, 9-days rainfall history, high rainfall alert with Green LED blinking, indication Selectable mm / inch unit, Outdoor temperature measurement, Digital clock with calendar • Automatic self-emptying rain cup • Outdoor Temperature Sensor • Measures and then empties collected rainfall • Wireless transmission range up to 30m for rain gauge and wireless outdoor thermometer • Displays daily, 9 day historical, and total rainfall records • Rainfall amounts are shown as inches or millimeters • Customizable daily rainfall alarm • Displays outdoor temperature Catalogue No Description EN44-264 Electronic Wireless Rain Gauge www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Meteorology EN44-266 The Weather Monitor gives continuous and acurate weather readings at a glance. Wind Speed and barometric pressure are both displayed by means of pointers, wind direction displayed by attractive LED lights positioned around the wind speed dial. External temperature (min / max) is shown by clear LCD display. All sensors are extremely robust with a high degree of accuracy and each is supplied pre-wired with 25 meters of cable. Installation is very simple as clear instructions are provided. Specification Wind Direction Resolution 16 points i.e. 22.5˚C Threshold 1.5m/s, 3Knots, 3.5 mph or 5km/h Wind Speed 80Kts, 90 mph, 145km/h ±7.5% Resolution Better than 1knot Meteorology Max Speed Indicated Accuracy Barometer Range 950 - 1050 mB Accuracy ±5mB Temperature ±0.5˚C @20˚C Resolution 0.1˚C Size, mm 255 (L) X 130 (H) X 55 (D) Power 220-240V 50 / 60 Hz and 12-24V d.c. Catalogue No Description EN44-266 Weather Monitor Cambell Stokes Sunshine Recorder The Campbell Stokes Sunshine Recorder is manufactured to the specifications of the British Meteorological Office The instrument is used to measure the duration of sunshine each day There are three types of measuring cards to correspond to the behaviour of the sun at different seasons: long curved for use in summer, straight for use near the equinoxes and short curved for use in winter EN44-268 Specification Latitude Adjustment Size, mm 0˚ to 40˚ N or S 102mm ±1.3mm diameter Focal length for sodium D light, 74.9mm ±0.25 240 x 187 x 165 Weight. kg 4.3 Catalogue No Description EN44-268 Campbell Stokes Sunshine Recorder EN44-270 Sunshine Cards: 1 year supply (150 summer / 150 winter / 100 equinoctial) Sphere EN44-272 Summer Cards: 100 cards EN44-274 Winter Cards: 100 cards EN44-276 Equinoctial Cards: 100 cards Aneroid Barometer EN44-278 Specification 980-1030 hpa ±1 hpa Size, mm / Weight g 130 dia x 35 / 550 Catalogue No Description EN44-278 Aneroid Barometer Telephone: +44 (0)1635 872 929 Training Training Range Accuracy Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring -40˚C to +50˚C Accuracy Toxic Gas Detection Range Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Weather Monitor www.wagtechprojects.com [email protected] 96 EN44-280 Barograph The Barograph is made with a solid metal base. The mechanism is machined & fabricated from high quality brass, polished and lacquered. Supplied with fabricated, vented sheet metal cover finished in blue hammer finish stove enamel and convenient carrying handle. Battery operated quartz clock with simple mechanism for changing rotation from daily to weekly or monthly or Clockwork clock Daily or weekly rotation selected by change gears provided Recording is effected by easily changed fibre tipped pen. Specification Range 950 to 1050hPa Accuracy +/- 0.5hPa Sensing element Aneroid capsule Catalogue No Description EN44-280 Barograph, supplied metal cover and carrying handle EN44-282 Pack of 200 daily charts EN44-284 Pack of 200 weekly charts EN44-286 Fibre tipped pen EN44-288 Digital Handheld Anemometer and Thermometer An easy to use hand held, electronic anemometer giving accurate wind speed measurement and ambient temperature. Specification EN44-290 Wind speed units in m/s, ft/min, knots, km/hr, mph Range 0 to 30 m/second 0 to 90 km/hour Accuracy +/- 5% Temperature -10 to +45° C Accuracy +/- 2ºC Dimensions, mm 105 x 40 x 15 LCD Dimensions, mm 23 x 32 Battery 3v lithium (CR2032) Catalogue No Description EN44-288 Digital Handheld Anemometer with Thermometer Hand Held Anemometer Very easy to use portable hand-held instrument providing a direct reading of wind speed in four different units on an engraved scale. With plastic outer case and cups. Specification Scales 0 to 120 kph, 0 to 12 Beaufort, 0 to 35 m/s, 0 to 70 knots Accuracy ±3% Threshold Approximately 2m/s Operating Temperature Ranges -35 to 45 ˚C Catalogue No Description EN44-290 Hand held Anemometer Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Meteorology 97 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Meteorology EN44-292 This 4 in 1 multi-function environment meter is a cost-effective introduction to aid conformance to health and safety in the work place. It measures Sound Levels, Light Levels, % RH and Temperature. The LCD display has large digits and function indicators. Lux %RH Range 35 to 130dB 0 to 20,000 25 to 95% Resolution 0.1 dB 0.01 Lux 0.11% Accuracy ±3.5 dB ±5% ±5% RH Operation 0°C to 40°C, below 80% RH Power 9V PP3 Alkaline Battery (ALR-61) Dimension, mm 250 x 90 x 30 Weight, g 392 Catalogue No Description EN44-292 4 in 1 multi-function environment meter Temp -20 to +750 °C 0.1 °C ±3% reading ±2°C Stevenson Screen Designed to hold a range of basic weather instruments. Made from good quality wood with double louvred sides and painted white. Size (mm): Interior:435 (L) x 250 (W) x 445 (H). Exterior:585 (L) x 405 (W) x 668 (H). Weight: 21kg Catalogue No Description EN44-294 Stevenson Screen Manual Weather Station EN44-296 A simple weather station comprising a range of conventional instruments housed in a Stevenson Screen to enable basic weather data to be collected daily. The complete station comprises the following instruments; Rain Gauge EN44-244 (page 95) Max / Min Thermometer EN44-200 (page 91) Wet & Dry Bulb Hygrometer EN44-208 (page 92) Hand Held Anemometer EN44-290 (page 97) Stevenson Screen EN44-294 (page 98) Catalogue No Description EN44-296 Manual Weather Station Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Sound Toxic Gas Detection Specification Meteorology • 2 Ranges for Sound with selectable ‘A’ or ‘C’ frequency weightings • Cosine corrected silicon diode sensor for Lux Levels • Semiconductor sensors in the probe for humidity & ambient temperature measurements • K-type input for °C / °F temperature measurements • 28mm LCD display with function indicators • Data Hold function freezes displayed value • Max Hold displays highest measured value • Max memory displays highest measured value since power on • Auto Power Off prolongs battery life • Low Battery warning • Standard 4mm camera bush for tripod mounting • Supplied in a carry case with Lux probe, Humidity / Temperature probe, K-Type wire probe wind muffler and battery Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis 4 in 1 multi-function environment meter Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 98 Toxic Gas Detection Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working conditions of staff and of the public in general. This section contains a range of simple gas detectors and multiple gas monitors widely used by engineers and technicians. Training Training Soil/ SediSoil/ Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboSediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Toxic Gas Detection 99 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Toxic Gas Detection EN55-102 Gas Range Standard Alarm EN55-102 Oxygen 0-25% 19 / 23% EN55-103 Hydrogen sulphide 0-100ppm 5ppm EN55-104 Carbon monoxide 0-500ppm 30ppm EN55-105 Sulphur dioxide 0-20ppm 1ppm EN55-106 Chlorine 0-20ppm 0.5ppm EN55-107 Nitrogen dioxide 0-20ppm 1ppm EN55-108 Ammonia 0-100ppm 25ppm EN55-109 Ozone 0-1ppm 0.1ppm EN55-110 Hydrogen 0-2000pm N/A EN55-111 Hydrogen cyanide 0-25ppm 5ppm EN55-113 Phosphine 0-5ppm 0.2ppm EN55-114 Fluorine 0-1ppm 0.1ppm EN55-115 Phosgene 0-1ppm 0.1ppm EN55-116 Nitric oxide 0-100ppm 25ppm EN55-117 Carbon dioxide 0-5% 0.5% Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Catalogue No Toxic Gas Detection Typical Response Times (T90) : Flammable 20s, Toxic Gas 20s, Oxygen 10s Gas Range Standard Alarm (UK): Flammable 0-100% LEL 20% Single unit charger with UK, EU or US plug or in-line 110V / 230V supply Dimensions 90 x 48 x 24mm H x W x D, Weight; approx 140g. Meteorology With rugged impact resistant construction and compliance to IP65, these detectors offer a wide range of gases including six flammable calibration options. Designed for use in the toughest environments they provide an unbeatable combination of powerful loud and bright alarms with a compact and lightweight design. Simple • True one button operation • Easy to read backlit display for gas diagnostics and operating status • Clear calibration due warning Alarms • 95dBA audible alarm • Striking twin red / blue visual alarm • Internal vibrating alarm • 2 levels of instantaneous alarm and TWA alarms for toxic versions Robust • Tough polycarbonate housing • Water and dust resistant to IP65 Flexible • Flammable, toxic and oxygen sensor solutions • Rechargeable and Li-ion battery versions available • Extensive data and event logging • Fully interchangeable intelligent sensor modules Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Gas Detectors Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 100 Training Training Soil/ SediSoil/ Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Toxic Gas Detection 101 EN55-208 Gas Detection Tubes Gas detection tubes are one of the most common forms of gas analysis. These versatile tubes make possible countless applications in industry, laboratory work, environmental protection and many other areas which require measurement results to be instantly available so that decisions can be made. There is also no need for calibration by the user – the calibration is shown in the form of a scale printed on the tube. Catalogue No Description EN55-202 Automatic pump for use with gas detection tubes supplied complete with tube opener and battery pack EN55-204 Battery Charger 6 V / 800 mA EN55-206 Spare Battery pack for Automatic Pump EN55-208 Hand Bellows Pump Set supplied with Carrying case and Tube opener Tubes Packs of 10 Ammonia 5/a Note: Many other tubes are available covering a wide range of gasses, please contact us for details Standard Range of Measurement Measurement Time [20 °C, 1013 hPa] [min.] 5 to 70 ppm 1 50 to 700 ppm 6s Catalogue No EN55-220 Benzene 15/a 15 to 420 ppm 4 EN55-221 Carbon Dioxide 100/a 100 to 3000 ppm 4 EN55-222 Carbon Disulphide 5/a 5 to 60 ppm 3 EN55-223 Carbon Monoxide 10/b 100 to 3000 ppm 20s EN55-224 10 to 300 ppm 3.5 Chlorine 50/a 50 to 500 ppm 20s EN55-225 Cyanide 2/a 2 to 15 mg/m3 2.5 EN55-226 Ethyl Benzene 30/a 30 to 400 ppm 2 EN55-227 Ethyl Glycol Acetate 50/a 50 to 700 ppm 3 EN55-228 Formaldehyde 2/a 2 to 40 ppm 30s EN55-229 Hydrazine 0.25/a 0.25 to 10 ppm 1 EN55-230 Hydrocarbons 0.1%/b 0.1 to 1.3 Vol% 3 EN55-231 Hydrogen 0.5%/a 0.5 to 3.0 Vol% 1 EN55-232 10 to 200 ppm 1 EN55-233 1 to 20 ppm 10 Hydrogen Sulphide 1/d Hydrogen Sulphide 100/a 100 to 2000 ppm 30s EN55-234 Mercaptan 20/a 20 to 100 ppm 2.5 EN55-235 Mercury Vapour 0.1/b 0.05 to 2 mg/m3 10 EN55-236 Nitric Acid 1/a 5 to 50 ppm 2 EN55-237 1 to 15 ppm 4 Nitrogen Dioxide 2/c 5 to 100 ppm 1 2 to 50 ppm 2 EN55-238 Nitrous Fumes 20/a 20 to 500 ppm 30s EN55-239 Nitrous Fumes 2/a 5 to 100 ppm 1 EN55-240 2 to 50 ppm 2 Oxygen 5%/C 5 to 23 Vol% 1 EN55-241 Ozone 0.05/b 0.05 to 0.7 ppm 3 EN55-242 Ozone 10/a 20 to 300 ppm 20s EN55-243 Pentane 100/a 100 to 1500 ppm 3 EN55-244 Petroleum Hydrocarbons 10/a 10 to 300 ppm 1 EN55-245 Petroleum Hydrocarbons 100/a 100 to 2500 ppm 30s EN55-246 Phenol 1/b 1 to 20 ppm 5 EN55-247 1 to 25 ppm 3 EN55-248 0.5 to 5 ppm 6 Sulphur Dioxide 0.5/a Sulphur Dioxide 20/a 20 to 200 ppm 3 EN55-249 Sulphuric Acid 1/a (9) 1 to 5 mg/m3 100 EN55-250 Toluene 100/a 100 to 1800 ppm 1.5 EN55-251 Toluene 5/b 50 to 300 ppm 1 EN55-252 5 to 80 ppm 5 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Toxic Gas Detection EN55-260 This monitor detects the presence of carbon monoxide in the surrounding area and warns the user both visually and audibly about dangerous gas concentrations e.g. when installing and servicing gas heaters. • No zero phase, instrument can be used immediately • Adjustable alarm threshold • CO zeroing at site Specification Measuring Range 0 to +1999 ppm Accuracy ±10 ppm (0 to +99 ppm) ±10 % (+100 to +499 ppm) ±20 % ( >+500 ppm) 1 ppm Resolution Operating Temperature Battery type 5 to +45°C Battery life 150 h (with beeper switched off) Reaction time 40 s Dimensions, mm / g 128 x 46 x 18. Weight : 350 Catalogue No Description EN55-260 Portable Ambient CO Monitor, includes, carrying case with belt clip, headphones, wrist strap, sampler and calibration protocol 2 batteries Type AAA Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Ambient CO Monitor Meteorology EN55-262 • Optical bar display • Sensor self-test after switching on • Rising alarm tone with increasing gas concentration • Continuous tone when alarm threshold is exceeded • Audible confirmation of readiness to operate • Battery monitoring with optical display Specification Methane Propane Measuring Range 0 to 20.000 ppm CH4 0 to 10.000 C3H8 Lower response thresholds 100 ppm CH4 50 C3H8 1st alarm limit 10.000 ppm CH4 (20% LEL) 5000 C3H8 (20% LEL) General Technical Data Operating Temperature -5 to +45 °C Battery Type 2 batteries type micro AAA 1.5 V (LR03) Battery Life 4 h (LR03) Dimensions, mm / g 128 x 46 x 18 Weight 300 Catalogue No Description EN55-262 Gas Leak Detector, including case with belt clip and wrist strap and batteries Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Highly practical gas leak detector for fast checks on gas pipe connections, with visual bar display. Toxic Gas Detection Gas Leak Detector Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 102 EN55-300 Personal Multi-Gas Detector This new range of multi gas detectors has been developed especially for personal monitoring applications. They are designed to measure up to 5 combustable gases & vapours. Specification Temperature -20 - +50 °C Pressure 700 - 1300 hPa Humidity Alarms 0 - 95% r.h. Visual 360° Vibrating and Audible Multi-tone 90 dB at 30 cm Ingress Protection IP 67 Operating time 12 hours (without Ex sensor > 700 hours) when using the Save Energy Mode > 40 hours Charging time 4 hours Can be read out via Infrared > 1,000 hours with 5 gases and a recording interval of 1 value per minute Maximum hose length 30 m; Data logger Pump operation Dimensions (W x H x D),mm 48 x 130 x 44 Weight, g 200 Catalogue No Description EN55-300 Personal Multi-Gas Detector basic instrument with an integrated data logger and calibration certificates (requires power pack). Choose up to four sensors EN55-301 Power pack & charging set Rechargeable NiMH power supply T4, charging module and a single charger (for worldwide use). EN55-302 GasVision Software Stores data for reports and exposure levels. Creates graphs and spreadsheets Catalogue No Gas Measuring Range Resolution Response Time (seconds) EN55-303 O2 EN55-304 CO 0 - 2000 ppm 2 ppm 15 EN55-305 H2S 1 ppm 15 EN55-306 CO / H2S 2 ppm / 1 ppm 20 EN55-307 NO 0 - 200 ppm 0 - 2000 ppm / 2 ppm 0 - 200 ppm 0.5 ppm 10 EN55-308 NO2 0 - 50 ppm 0.1 ppm 15 EN55-309 SO2 0 - 100 ppm 0.1 ppm 10 EN55-310 HCN 0 - 50 ppm 0.1 ppm 10 EN55-311 CO2 0.5 Vol. % 0.1 Vol. % 30 EN55-312 Ozone 0 - 10 ppm 0.01 ppm 10 EN55-313 OV (Organic Vapour) 0 - 200 ppm 0.5 ppm 20 0 - 25 Vol % 0.1 Vol. % 10 Note: A wider range of sensors and accessories are available for this product, please contact us for the full list. Training Training Soil/ SediSoil/ Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Toxic Gas Detection 103 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Toxic Gas Detection EN55-400 This detector will measure up to five gases simultaneously and continuously. A combination of more than 25 sensors allows flexible solutions to individual monitoring tasks. It is the ideal companion in a variety of applications where the reliable detection of oxygen, toxic and combustible gases and vapours is necessary. Specification Temperature -20 - +50 °C Pressure 700 - 1300 hPa Humidity 0 - 95% r.h. Alarm - Visual Alarm - Vibrating and Audible Multi-tone Ingress Protection 360° Operating time Data logger IP 67 12 hours (without Ex sensor > 700 hours) when using the Save Energy Mode > 40 hours 4 hours Can be read out via Infrared > 1,000 hours with 5 gases and a recording interval of 1 value per minute 140 x 150 x 75 Weight, kg 1.1 Catalogue No Description EN55-400 Portable Multi-Gas Detector 5 Gas Analyser, basic unit including a calibration adapter, water and dust filter. Requires power pack, charging module & power supply EN55-401 Rechargeable power pack NiMH 4.8 V / 3.0 Ah EN55-402 Charging module EN55-403 Power supply for one charging module EN55-404 Power Supply for up to seven charging modules Catalogue No EN55-410 CO 0 – 2000 ppm EN55-411 H2S 100 0 – 100 ppm EN55-412 OV (Organic Vapour) 0 – 200 ppm EN55-413 NO 0 – 200 ppm EN55-414 NH3 0 – 300 ppm EN55-415 NO2 0 – 50 ppm EN55-416 SO2 0 – 100 ppm EN55-417 Cl2 0 – 20 ppm EN55-418 CO2 0 – 5 Vol.-% EN55-419 H2 0 – 2000 ppm EN55-420 O2 100 0 – 100 Vol.-% EN55-421 O2 LS 0 – 25 Vol.-% EN55-422 H2S 0 – 100 ppm EN55-423 IR CO2 0 – 5 Vol.-% Note: A wider range of sensors and accessories are available for this product, please contact us for the full list. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Maximum hose length 30 m; Dimensions (W x H x D),mm Toxic Gas Detection Pump operation Meteorology Charging time 90 dB at 30 cm Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Multi-Gas Detector Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 104 Air / Dust Sampling & Monitoring Dust consists of particles in the atmosphere that originate from various sources such as soil dust raised by the wind, volcanic eruptions, and pollution caused by human activity. Dust in homes, offices, and other human environments contains small amounts of plant pollen, human and animal hairs, textile fibers, paper fibers, minerals from outdoor soil, human skin cells, and many other materials which may be found in the local environment. The presence of excessive and/or contaminated dust particles in the atmosphere is both unpleasant and potentally harmful to human and animal health and the equipment in this section is designed to sample and monitor these levels. Training Training Soil/ SediSoil / Water Air / Dust Laboratory Noise && Laboratory Noise Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Quality Sampling & Toxic Air Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air/ Dust Sampling & Monitoring 105 www.wagtechprojects.com [email protected] Telephone: Telephone: +44 (0)1635 872 929 Air/ Dust Sampling & Monitoring Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Ambient Dust Sampling Meteorology EN65-110 Catalogue No Description EN65-110 Dust Deposit Gauge-Frisbee Type-Complete Kit with sticky pad adapter and 2 x 5 litre bottles. EN65-112 Spare HDPE Bottle-5litre-with standard cap EN65-114 Spare Foam Particle Trap Dust Deposit Gauge A low cost dust gauge that measures dust flux, ie the horizontal component of wind-blown dust and is measured in milligrams per square meter per day (mg/m2/day). The unit complies with BS1747 part5. EN65-116 • 4 x 1000ml HDPE collecting bottles with internal seal • 1 x 600ml wash bottle • 4 spare collecting bottles • Calibration data • Overall height 1.6m, weight approx 14kg Description EN65-116 Directional Dust Gauge, complete kit EN65-118 Spare Collecting Bottle for Directional Dust Gauge Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Training Catalogue No Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring A low cost dust gauge that measures dust deposition, i.e. dust falling from the sky and is measured in milligrams per square meter per day (mg/m2/day) • Anodized aluminium frisbee-type collector with 227mm diameter aperture • Large capacity collecting bottle will accommodate 120mm rain (240mm with the 10-litre bottle) and has wide neck permitting easy access for cleaning and removal of Polyester foam dust trap • Spare dust trap and bottle • Sticky pad adapter for determining prevailing direction • Bird guard reduces risk of polluted samples from bird strikes • Tripod base, which can be spiked down, ensures stability on uneven surfaces • Weight approx. 8kg Toxic Gas Detection Dust Deposit Gauge 106 EN65-200 Air Sampling Pump This highly versatile air sampling pump provides high-performance sampling for asbestos and other particulates. The unit is enclosed in a robust steel casing, a front mounted power socket to provide easy access for charging or powering, and a sturdy handle for easy portability. Use the fully programmable timer to set a manual run, a timed run with or without delayed start, or intermittent sampling. Ideal for: area and environmental monitoring, bio-aerosol sampling, indoor air studies, asbestos monitoring, long term background monitoring, and stack sampling • Wide flow range: 2 to 26 L/min to free air • Fully programmable • Manual run •Timed run and delayed start • Intermittent sampling • Robust steel casing with sturdy handle for easy portability • Long run times • High-performance sampling capabilities • Convenient front mounted power socket • Battery or mains AC operation • Flow fault feature ensures sample integrity • Run time display is retained during fault • Operating temperature: -5 to 50oC • Weight: 6.9kg • Size 18 x 11 x 20 cm EN65-210 Catalogue No Description EN65-200 Air Sampling Pump, 2 - 26 litres / min, supplied complete with rechargeable battery, charger & 1m tubing EN65-202 Aluminium Sampling Mast, 1m EN65-204 25mm Open Face Sampling Head EN65-206 G.F / A filters for general sampling of “Inhalable” and “Respirable” dusts 25mm, pkt 100 EN65-208 Rotameter 2.0-26.0 L/min, calibration accuracy Class 2.5 VDI / VDE General Dust Sampling & Monitoring Kit Designed for personal monitoring in work areas this kit will help you to maintain a record of dust levels in the workplace at minimal cost. Rotameter and stand, I.O.M sampling head with cassette, tweezers, accessory container, all in a plastic carry case. Catalogue No Description EN65-210 General Dust Sampling & Monitoring Kit EN65-212 GFA Pre-Weighed Filters 25mm (Pkt of 10) Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air/ Dust Sampling & Monitoring 107 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Air/ Dust Sampling & Monitoring Hand Held Airborne Particulate Monitor EN65-250 The Handheld Airborne Particulate Monitor is a small and compact instrument that can be used to study short to long term monitoring of airborne dust particles in both indoor and outdoor environments. • Real time air quality monitoring • Simultaneous TSP, PM10, PM2.5 and PM1 monitoring • Ideal for portable workplace monitoring of atmospheric dust Specification Laser nephelometer Standard inlet Environmental mode TSP (1mm stainless mesh) Range 0 to 6000 micrograms per cubic meter Detection limit 0.01 micrograms per cubic meter Particle size range 0.5 to 20 micron diameter Flow Rate 600cc per minute Internal Memory 32kB Power supply Rechargeable battery Dimensions, mm / weight, kg 160 x 100 x 100, 1.2 Catalogue No Description EN65-250 Handheld Airborne Particulate Monitor, supplied with battery pack, charger, PC cable, software, spare filters, and carrying case. TSP, PM10, PM2.5, PM1.0 EN65-252 Toxic Gas Detection Airborne Particulate Monitor is a small and compact instrument that can be used to study short to long term monitoring of airborne dust particles. The particulate monitor can be used effectively to determine particle concentration in the local area along with wind speed and direction. • Real time air quality monitoring • Simultaneous TSP, PM10, PM2.5 and PM1 monitoring • Multiple units can be installed in networks Specification Laser nephelometer Standard inlet TSP (1mm stainless mesh) Heated inlet Heating to 60°C Environmental mode TSP, PM10, PM2.5, PM1.0 Range 0 to 6000 micrograms per cubic meter Detection limit 0.01 micrograms per cubic meter Particle size range 0.5 to 20 micron diameter Flow Rate 600cc per minute Alarm to phone or email Internal memory 128kB Power supply Rechargeable battery Dimension, mm / weight, kg 260 x 160 x 150 / 11.8 Catalogue No Description EN65-252 Airborne Particulate Monitor, includes lamp post box, battery, charger, PC cable, software, and spare filters EN65-254 Anemometer EN65-256 GSM / GPRS modem EN65-258 Solar Panel Kit Training Training Telephone: +44 (0)1635 872 929 EN65-258 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Airborne Particulate Monitor Detector Meteorology Detector Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Ambient Dust Monitoring www.wagtechprojects.com [email protected] 108 Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air/ Dust Sampling & Monitoring 109 EN65-300 Portable Ambient Air Sampler (PAAS) The Portable Ambient Air Sampler (PAAS) is an air sampler for particulate matter. The patented low flow technology used in the PAAS was developed with the USEPA in an effort to address the need for portable air pollution sampling technology. Whilst not a reference method sampler, the PAAS gives results that closely approximate reference method air quality data. Both accurate and precise, the battery operated, lightweight PAAS is ideal for sampling at remote sites or areas without power. In addition, the low cost of the sampler allows a network of PAAS to be deployed at a fraction of the cost for a similar reference station network. The PAAS features a 7-day programmable timer, a constant flow control system, an elapsed time totaliser, rechargeable battery packs, and all-weather PVC enclosure. The PAAS can separately sample particulate matter in the TSP, PM10, and PM2.5 range. Specification Double-diaphragm with laminar flow valve technology Pump Rated for 10,000 hours continuous operation Flow range 0-10 Litres / min Timer Up to six sample periods per day Easily removed for cleaning Pre-separator / Cassette Filter Holder Assembly Standard 47mm filter holder Nominal 10 micron or 2.5 micron “cut-point” at 5 litres / minute sample rate AC or DC operation Variable flow adjustment Electronics Elapsed time totaliser Low battery indicator and shut-off Low flow rate indicator and shutoff 14.8V / 118 Watt Hours Battery Pack 1.2 amp external battery charger, 100-240VAC, 47-63Hz, Full recharge in less than 6 hours Dimensions: 25 x 30 x 18cm Weight: less than 5kg fully configured Enclosure All-in-one transport case Dimensions: 50 x 30 x 46cm Weight: less than 18kg with all accessories Catalogue No Description EN65-300 Portable Ambient Air Sampler for TSP & PM-10 sampling includes: Pump Module, 2 x PM-10 Impactors, 2 x Louvered Inlets, 2 x Filter Holder Assemblies, 2 x Battery Packs, Battery Charger, Universal Mounting Bracket, and an all-weather transport case. EN65-302 Portable Ambient Air Sampler for TSP, PM10 & PM-2.5 sampling includes; Pump Module 2 x PM-10 Impactors, 2 x PM-2.5 Impactors, 2 x Multiple Impactor Adapters, 2 x Louvered Inlets, 2 x Filter Holder Assemblies, 2 x Battery Packs, Battery Charger, Universal Mounting Bracket, and an all-weather transport case EN65-304 Fibre film filters, recommended for PM10 gravimetric analysis, 47mm dia, pack of 50 Pure Teflon filters, recommended for PM2.5 gravimetric analysis, 47mm dia, pack of 50 EN65-306 EN65-318 Quartz filters, alternative to Teflon filters, 47mm dia, pack of 100 Petrislides, plastic cassettes for shipping and storage of filters, pack of 100 Field Calibration Kit w / Digital Manometer EN65-320 Solar Panel Assembly for Portable Ambient Air Sampler EN65-308 EN65-310 www.wagtechprojects.com [email protected] Telephone: Telephone: +44 (0)1635 872 929 Air/ Dust Sampling & Monitoring EN65-340 Ideal for weighing dust samples this micro balance is equipped with a high performance force compensation weigh cell that is very precise, but also exceptionally reliable and durable. The built-in, motorized calibration weight activates by the touch of a key and activates automatically when the ambient temperature changes by a specific value. The internal ionizer neutralizes electrostatically charged objects instantly, which removes errors caused by static electricity. The balance automatically adjusts its response characteristics (FAST, MID, or SLOW) by analyzing the influence of drafts or vibrations on the stability of the display value. 5.1g / 22g Minimum Capacity Readability 0.001mg / 0.01mg Resolution Repeatability (std. deviation) Linearity 0.001mg / 0.01mg Pan Size 25mm Ø Power supply 220 / 240VAC 50 / 60Hz mains adapter Catalogue No Description EN65-340 Micro Analytical Balance, dual range, capacity 5.1g x 0.001g and 22g x 0.01g, includes weighing pan for 50 and 95mm dia dust filters EN65-342 Anti Vibration Table EN65-344 Table Top Breeze Break 0.001mg / 0.01mg 0.004mg (for 1g) / 0.01mg +/-: 0.010mg / 0.02mg Note: Unable to locate the precise instrument you require? Please contact us for expert advice. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Capacity Toxic Gas Detection Specification Meteorology • Built in Fanless Ionizer • Interlockable Sliding Doors • Internal Calibration Mass • Automatic Response Adjustment • Reverse Backlit LCD Display • Twelve weighing units • GLP / GMP / GCP / ISO compliant output • Data memory function • RS-232C and Quick USB interfaces as standard • Counting mode • Automatic Counting Accuracy Improvement (ACAI) • Percent mode function • Comparator function with buzzer • Auto power on function • Underhook function • Density determination function • Built-in temperature, humidity & atmospheric pressure sensors • Special pans and holder for dust particulate filter weighing Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Micro Analytical Balance Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 110 Air Quality Monitoring Good air quality is essential to the health and well-being of all living organisms. Poor air can have adverse effects on our quality of life and can damage the fabric of buildings and sensitive flora and fauna. Air quality monitoring provides raw measurements of air pollutant concentrations and with appropriate analysis and interpretation, these measurements can be transformed into useful information about air quality. Training Training Mobile Mobile LaboLaboratories ratories Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Air Quality Quality Air Toxic Gas ment Sam- Hydrology & Water Quality Toxic Gas Sediment Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Monitoring Detection Sampling Testing pling & & Groundwater Monitoring Detection Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air Quality Monitoring 111 111 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Air Quality Monitoring EN73-102 The Air/Vapour Sampling Kit, has been designed to take air or vapour samples using standard Tedlar air sampling bags and contains the following components all housed in a durable carrying case: • Air Sampling Pump, twin port, constant flow rate 20 to 225 litre/min • Battery Charger • One Metre Length of Tygon Tubing • Tedlar Air Sampling Bags, capacity 1 litre (pack of 10) • Instruction Manual and Step by Step Guide Specification Flow rate, constant 20 to 225 litre / min Accuracy Typical run time +/-5% in constant flow mode Battery charge time approx 6 hours Operating Temperature 0 to 45ºC Flow fault after 15 secs, pump goes into Hold, retains accumulated run time display, and displays fault icon Timer 1 to 9999 min display +/- 1% accuracy Battery Charger 230V, AC 50hz Kit dimensions, cm 45 x 30 x 8 Weight, kg 1 Catalogue No Description EN73-102 Air / Vapour Sampling Kit EN73-101 Air / Vapour Sampling Bags (Pack of 10) 12 hours at 200 litre/min Meteorology Toxic Gas Detection All of the testing methods used in each outfit are performed by collection of the gas in a special absorbing solution and the subsequent chemical analysis. Through the use of these methods, better quantitative results may be obtained than results acquired by gas indicator tubes or length of stain methods. Each analytical method has been appropriately modified to make the entire outfit suitable for testing either field levels or levels in confined areas. Precision impinging units and general purpose impinging units are included in the outfit. Packaged in a rugged plastic container, each analytical test module is easily removed from the outfit for individual investigations. Sufficient reagents are supplied to perform 25 tests with a total capacity of 150 tests for the entire combination outfit. Inexpensive refill packages of the chemical reagent are available. Air Pollution Sampling Pump For use with the Air Pollution Test Kit in monitoring atmospheric air pollution, checking eight-hour exposure limits for workers in industry, and more. The brushless DC motor pumps air to a small diaphragm valve assembly which maintains flow rates for 48 hours of continuous sampling before the batteries need replacing. Intermittent sampling extends the range of usage considerably. A quality flowmeter accurately monitors the volumes of air being sampled. The flowmeter has an easy-to-read scale calibrated from 0.2 to 2.0 litres per minute (lpm) and can be adjusted. Readings are in 0.1 lpm. Supplied complete with flowmeter, impinger holder, batteries, connection tubing, and carrying case. Power supply, 4 x C cell batteries Dimensions: 25cm(w) x18cm(d) x15cm(h). Weight: 2.7kg. Description EN73-104 Air Pollution Test Kit tests for Ammonia, Chlorine, Lead, Nitrogen Dioxide, Sulphur Dioxide, and Total Oxidants EN73-106 Refill Unit for all reagents in EN73-104 EN73-108 Air Pollution Test Kit tests for Ammonia, Carbon Monoxide, Chlorine, Hydrogen Sulphide, Nitrogen Dioxide, and Sulphur Dioxide EN73-110 Refill Unit for all reagents in EN73-108 EN73-112 Air Pollution Sampling Pump for use with Air Pollution Test Kit (EN73-104 & EN73-108), www.wagtechprojects.com [email protected] Training Training Catalogue No EN73-112 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring EN73-104 Air Pollution Test Kit Telephone: +44 (0)1635 872 929 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Air / Vapour Sampling Kit 112 EN73-300 Urban Pollution Monitor (UPM) Developed to monitor the effects of traffic flow, the UPM provides real time recording of local air pollution levels.Using a microprocessor controlled logger, the UPM can monitor and record information on a whole range of airborne pollutants and cross reference them to site specific data such as temperature and relative humidity. A wide range of sensor configurations is possible, with options for up to 3 electrochemical gas sensors, PM monitor, met sensors and sound. Depending on the configuration chosen, the sample gas may be pumped into the unit or allowed to diffuse through natural air movement. Additional flexibility is achieved with a wide range of power options, from standard mains power to internal or external battery. Constructed from weatherproof plastic, the UPM is environmentally sealed in a rugged, compact enclosure. Fixing is via a twin aperture bracket that allows fitting to most industrial or urban sites within minutes. This makes it ideal for short to medium term testing periods. The logger has the capability to record up to several months of time stamped 15 minute averages. All data gathered is held in memory by an on-board lithium cell which allows all operational settings to be retained without external supply. The UPM houses its own communications system so no need for hard wired telemetry. The integral radio link is capable of communicating with a dedicated base station up to 20 metres away, whilst the GSM option allows data recovery or program changes from almost anywhere. EachUPM is individually identified, which allows the use of several loggers within a data gathering network. The supplied operational software is Windows™ compatible and supplied for multi user installation. Information on logger status, battery life and the dynamic state of all operational parameters is available via an easy to use pull down menu. Specification Enclosure Weatherproof plastic 280 mm x 168 mm x 123 mm deep Weight, kg 1.8 Power Requirement 12 V DC <50 mA Battery Life: Six months plus temperature and battery status Memory 500 Kbytes as standard Power supply 220 / 240VAC or battery power depending on sensor configuration Electrochemical Sensor Gas Range Resolution Carbon monoxide 0-1000 ppm 0.1 ppm Nitrogen dioxide 0-10 ppm 20 ppb Sulphur dioxide 0-10 ppm 25 ppb Nitrous Oxide 0- 100ppm 0.5ppm Hydrogen Sulphide 0-10ppm 0.1ppm Repeatability 1% of signal Span drift <1% per year Response time <40 seconds Temperature range -20 to +50ºC Sensor life up to 2 years, depending on levels measured PM10 Particulate Sensor Sensor type Forward light scatter Sensitivity 1µg/m³ Precision 0.0031µg/m³ or 2% of reading Long term stability 5% of reading Training Training Mobile Mobile LaboLaboratories ratories Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Toxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air Quality Monitoring 113 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Air Quality Monitoring Description EN73-300 Urban Pollution Monitor supplied with 3 sensors, mains powered with pump, data logger, radio and RS232 comms and mounting kit. Select 3 gas sensors OR 2 gas sensors and PM10 particulates sensor. EN73-302 Carbon Monoxide(CO) EN73-304 Nitrogen Dioxide(NO2) EN73-306 Sulphur Dioxide (SO2) EN73-308 Nitrous Oxide(NO) Hydrogen Sulphide (H2S) PM10 Particulates Sensor EN73-314 PID / VOC Sensor EN73-316 Windspeed & Direction Sensor EN73-318 Radio Base Station for data download. EN73-320 GSM communication (replaces the radio & RS232 option) Note: Toxic Gas Detection Up to 3 of the above gas sensors or 2 gas sensors plus the PM10 particulates sensor together with PID/VOC,sensor, and windspeed & direction sensor can be ordered with any UPM unit (EN73-300) Meteorology EN73-310 EN73-312 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Catalogue No Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 114 Training Training Mobile Mobile LaboLaboratories ratories Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Toxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air Quality Monitoring 115 Industrial Flue Gas & Vehicle Exhaust Emission Monitoring Portable Gas Emissions Analyser EN73-402 Portable 8 Gas Analyser is the most accurate, robust and flexible portable flue gas analyser currently available. • Measures 8 gases in a single instrument • Monitors of up 17 measurement parameters • Robust, light weight, industrial design with widescreen colour display for daily use in the harshest plant environments • Wake and Sleep, semi-continuous operation mode • Multiple language support • USB Comms interface to PC & data transfer - supports USB memory sticks • Data acquisition & analysis software. • Self diagnostic checks are run continuously on calibration status and battery life. • Smoke Probe Option, length 0.3m (incl 3m hose, filter paper, chart and inline flow meter) other probes available on request • Flue Gas Temperature: Max. 600 °C standard, Max. 1400 °C with High Temperature Probe option Sensor Minimum Range Maximum Range Accuracy % of Range Resolution o2 0 to 25% v/v 0 to 30% v/v ±1% Co (low) 0 to 100 ppm 0 to 6000 ppm ±2% 0.1% v/v 0.1 ppm Co (H2 comp) 0 to 100 ppm 0 to 4000 ppm ±2% 0.1 ppm Co (high) 0 to 4000 ppm 0 to 10 % ±2% 0.1 ppm So2 0 to 100 ppm 0 to 4000 ppm ±2% 0.1 ppm No 0 to 100 ppm 0 to 5000 ppm ±2% 0.1 ppm No2 0 to 100 ppm 0 to 1000 ppm ±2% 0.1 ppm H2S 0 to 200 ppm 0 to 1000 ppm ±2% 0.1 ppm Co2 0 - 25% v/v ±2% 0.1% v/v Hydrocarbons (CxHy ) 0 to 4% v/v (Calibrated as methane) 0.1% v/v Specification Note: Please contact Wagtech Projects for a further range of probes and accessories available for this product Power Supply 95-265 VAC ±10%, 50-60 Hz, 30 Watts. Battery, rechargeable lead-acid (internal). Typical 8 hour operation. Dimensions, mm 453 x 120 x 245 Weight. kg 6 Standard Instrument is supplied complete with integral sampling pump, water catchpot and gas filters, rechargeable batteries, battery charger, probe handle, 3m hose with Standard Probe, length 0.3m. Catalogue No Description EN73-402 Portable Gas Emissions Analyser EN73-404 Data Acquisition Software EN73-406 Printer Module with rechargeable batteries & charger EN73-408 Smoke Probe, length 0.3m (incl 3m hose, filter paper, chart and inline flow meter) EN73-410 High Temperature Probe, 0.3m length EN73-412 Carrying Case www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Air Quality Monitoring This portable gas analyser is the complete tool for the modern emission monitoring engineer. Highly portable and easy to use, it is a perfect back-up to continuous systems or when random spot-checking is required. The differential pressure and temperature connections allow precise burner and pump set-up, whilst the exhaust gases can be monitored over user defined time periods, confirming pollution controls. Range Resolution Accuracy Oxygen 0 - 25% 0.1% Carbon Monoxide 0 - 10,000ppm +/- 1ppm Nitric Oxide 0 - 1,000ppm +/- 1ppm Nitrogen Dioxide 0 - 200ppm +/- 1ppm +/- 0.3% <100ppm;+/- 5ppm >100ppm +/- 5% <100ppm;+/- 5ppm >100ppm +/- 5% <20ppm;+/- 2ppm Sulphur Dioxide Carbon Dioxide (calculated) CO / CO2 ratio 0 - 2,000ppm +/- 1ppm <100ppm;+/- 5ppm 0 - 0.9999 Combustion efficiency 0 - 100% 0 - 25% Nitrogen Dioxide 0 - 200ppm +/- 1ppm <20ppm;+/- 2ppm >20ppm;+/- 5% Sulphur Dioxide 0 - 2000ppm +/- 1ppm <100ppm;+/- 5ppm >100ppm;+/- 5% Hydrogen Sulphide High Capacity Carbon Monoxide (in lieu of standard) 0 - 200ppm +/- 1ppm <40ppm;+/- 2ppm >40ppm; +/- 5% 0 - 100,000ppm +/- 1ppm <100ppm;+/- 5ppm >100ppm;+/- 5% Instrument Operating temperature range -5°C to 50°C Battery Rechargeable Ni-Cd.. Life 4-5 hours, charge time 2 hours Charger input voltage 115V or 230V; 50 / 60Hz AC Data logging / Printing Printing user configurable, 75 set of readings, through RS232 Dimensions, mm / Weight, kg 280 x 120 x 112 / 1.3 Probes K-type thermocouple Pistol grip; 250mm stainless steel probe length; depth gauge; 2.5m hose length Accuracy +/- 0.3%; +/- 1°C Maximum temperature 800°C with 1,100°C available on request Construction Draught / pressure measurement Range +/- 150mbar Resolution 0.01mbar Accuracy +/- 0.5% fsd measured at 50mbar K-Type thermocouple Accuracy +/- 0.3%; +/- 1°C Catalogue No Description Portable Flue Gas Analyser, with sensors for O2, CO, NO, supplied with carry case Select 3 sensors from following; EN73-420 Nitrogen Dioxide (optional sensor) EN73-422 Sulphur Dioxide (optional sensor) EN73-423 Hydrogen Sulphide (optional sensor) EN73-424 High Capacity Carbon Monoxide (optional sensor) Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Training EN73-421 Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Optional Gas Sensors Toxic Gas Detection Standard Gas Sensors Meteorology • Measures; oxygen, carbon monoxide, and nitric oxide as standard • Optional sensors for; Nitrogen Dioxide, Sulpher Dioxide, Hydrogen Sulphide. Calculates; Carbon Dioxide Nitrous Oxides • 7 fuel types (natural gas, propane, butane, heavy & light oil, coal & coke) • Integrated printer with one button operation • High quality 250mm stainless steel probe for temperature (up to 800°C) and gas measurement with 2.5m of hosing • User configurable logging up to 75 reports, transferable to standard Windows software • Integrated water trap with easy to change dual filtration Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Flue Gas Analyser 116 EN73-430 Vehicle Exhaust Gas Analyser A hand held unit used for the measurement of Carbon Monoxide, Hydrocarbons, Carbon Dioxide, Oxygen and Nitrogen Oxides, this analyser is ideal for emission diagnostics, tuning, pre-compliance and regulated testing applications. • Simple one-time set up procedure. Easily select between Petrol (Gasoline), Liquid Petrolyeum Gas / Autogas (LPG), Compressed Natural Gas (CNG) and Diesel settings • Logging and auto-logging – memory stores up to 255 sets of full results. Tests stored manually or automatically timed. Results downloaded to a PC using optional software (see accessories) • The analyser includes an integral IR transmitter that is compatible with the optional printers so that results can be recorded anywhere • Additional features include Lambda / AFR measurement, Corrected CO, RPM and Oil / Exhaust gas temperature measurements Specification Sensor response 15 seconds Pre-programmed fuels Petrol, LPG and CNG Ambient operating range +5°C to +45°C / 10% to 90% RH non condensing Storage temperature Minimum 0°C Maximum +50°C Battery charger Input 110 Vac / 230 Vac nominal. Output 10 Vac off load Dimensions, mm 220 x 55 x 120 Weight, kg 1.1 Range Resolution Accuracy Carbon Monoxide (Infrared) 0-10% Over-range 20% 0.01% ±5% of reading ±0.06% volume Oxygen (Fuel Cell) 0-21% 0.01% ±5% of reading ±0.1% volume Hydrocarbon (Infrared) 0-5,000ppm Over-range 20,000ppm 1ppm ±5% of reading ±12% volume Carbon Dioxide (Infrared) 0-16% Over-range 20% 0.1% ±5% of reading ±0.5% volume 0-5,000ppm 1ppm 0-4,000ppm ±4% or 25ppm 4,000-5,000ppm ±8% 0-150°C 1°C ±2°C ±0.3% of reading ±4°F ±0.3% of reading 200-6,000rpm 1rpm 50rpm 0.8-1.2 0.001 0.01 NOx (Electro-Chemical) Oil Temperature RPM Optional Lambda AFR Petrol AFR LPG Catalogue No Description EN73-430 Vehicle Exhaust Gas Analyser includes gas analyser with water trap and calibration report, plastic carry case, battery charger, mains lead, high temperature exhaust probe, 12V adapter cable and spare filters. Accessories EN73-432 Software kit with CL3 lead for PC interface EN73-434 Infrared Printer with thermal paper and AA batteries EN73-436 Pack of 5 Thermal Paper Rolls for Printer EN73-438 RPM Clamp EN73-440 Oil Temperature Probe Training Training Mobile Mobile LaboLaboratories ratories Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Toxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air Quality Monitoring 117 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Air Quality Monitoring Radiation Survey Meter EN73-502 Radiation detected Beta > 100 keV Gamma > 7 keV Response time 0 mR/h to 5 mR/h (8 sec) 0 mR/h to 50 mR/h (2.5 sec) 0 mR/h to 500 mR/h (2 sec) 0 R/h to 5 R/h (2 sec) 0 R/h to 50 R/h (2 sec) Accuracy Within 10 % of readings between 10 % and 100 % of full scale indication on any range, exclusive of energy response Detector Chamber (cc volume air ionization) 349 cc Chamber wall (phenolic) 246 mg/cm2 Chamber window (mylar) 6.6 mg/cm2 Beta slide 440 mg / cm2 Automatic features Auto-zeroing, auto-ranging, and auto-backlight Power requirements Two 9 V alkaline, 200 hours operation Warm-up time One minute Display Analogue / digital with backlight Environmental Temperature range: -20ºC to +50ºC Relative humidity : 0 % to 100 % (at 60ºC) Geotropism: < 1 % 10 x 20 x 15 / 1.11 Catalogue No Description EN73-502 Radiation Survey Meter Telephone: +44 (0)1635 872 929 Training Training Dimensions, cm / weight, kg Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Specification Toxic Gas Detection Used by X-ray manufacturers, state inspectors, government agencies, police and fire departments, emergency response and hazmat teams, nuclear medicine labs, hospital radiation safety officers, nuclear power workers • Detects skin-dose - beta particle and deep-dose gamma and X-ray radiation • Requires no adjustments; simple two button operation • Delivers quickly read, correct value through autoranging capability • 30 % more accurate than other available meters • More than one week of continuous operation from 2x 9-volt alkaline batteries • Measures both dose and dose-rate • Useful for contamination-detection, general radiation area surveys, radiation- level monitoring, and hazardous materials assessment • Ruggedised design Meteorology The Radiation Survey Meter is a portable and practical means for identifying irradiated goods, and for helping remediate contamination and safety issues while minimally impacting operations. Use of the device reassures employees that radiation risks are known, monitored and measured for their protection. If radiation is found, a clear and quantifiable result allows managers to comply federal guidelines, without overreacting with unnecessary steps that might halt operations, impact productivity or lead to lost revenue. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Radiation Detectors www.wagtechprojects.com [email protected] 118 EN73-504 Nuclear Radiation Monitor This monitor is used widely by hospitals, laboratories, industry, police departments, fire departments and other emergency response agencies. The digital display shows readings in a choice of counts per minute (up to 50,000 cpm) or mR/hr (up to 50 mR/hr) or in accumulated counts. A red LED blinks and a beeper chirps with each count. • Data output and built-in timer let you document radiation activity over selected sampling periods • Removable test plate for general surveying • Measures alpha, beta, gamma, and x-radiation • Provides precision radiation monitoring • User-adjustable levels with audio / visual alarm indicators • Set timer for periods of 1 to 10 minutes in one-minute increments, 10 to 50 minutes in ten-minute increments, or 1 to 24 hours in one-hour increments • 4-digit LCD with auto-ranging bar graph updates readings every three seconds. • Excellent sensitivity to low levels of alpha, beta, gamma, and X-rays. • Anti-saturation circuitry holds readout at full-scale in fields up to 100 times the maximum reading. Specification Range mR/hr: 0.001 to 100 cpm: 0 to 300,000 total counts: 1 to 9,999 (x1000) cps: 0 to 5000 mSv/hr: 0.1 to 1000 Accuracy ±1.5% up to 20 mR/hr (130,000 cpm), ±20% above these values Function (50mm-dia source against screen) Source: Sr-90 Efficiency: 38% Source: 14C (0.130 µCi) Efficiency: 5.3% 50mm diameter “pancake” uncompensated Geiger Mueller tube with mica window adjustable timer, external calibration control Window 4.4 cm dia; 1.5-2.0 mg / cm2 thick Power One 9 V battery Dimensions (WxHxD), mm 82 x 150 x 30 Weight, g 150 Catalogue No Description EN73-504 Nuclear Radiation Monitor, supplied complete with external GM tube probe with anodized aluminized housing, black foam grip, and a 9V battery, and padded carrying case. Sensitivity Detector Training Training Mobile Mobile LaboLaboratories ratories Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Toxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Air Quality Monitoring 119 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Air Quality Monitoring EN73-506 The entry of radon gas into buildings can be dependent upon a number of factors. Understanding which factors are responsible can help in determining the most effective remedial measures. The concentration of Radon in the ground is produced by uranium which is radioactive and is naturally present in all rocks and soils to varying degrees and, when present in soil gas, can result in radon levels in significant concentrations. Similarly, ground situated over metal ore seams or mines can have high levels of radon gas within it and, as a result, ground gas is drawn into properties and high radon levels can be present in the building. This Portable Radon Monitor is an easy-to-use battery operated instrument for use in all types of buildings and gives fast and precise measurement of the radon level. Specification 20% after one week with 100 Bq/m3 10% after one month with 100 Bq/m3 0ºC to 40ºC and Relative humidity below 95% Power Three LR03 (AAA alkaline) batteries Battery lifetime Approximately 3 years at 100Bq/m3 Dimensions, mm / Weight, g 20 x 69 x 22.5 / 130 Catalogue No Description EN73-506 Portable Radon Monitor Toxic Gas Detection Operation Environment Meteorology Short-term measurement value Long-term measurement value Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Portable Radon Monitor Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring For all your safety equipment needs please see our General Lab Catalogue Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 120 Training Training Mobile Mobile LaboLaboratories ratories Laboratory Laboratory Analytical Analytical Equipment Equipment Soil/ SediSoil / Noise && Water Noise Air / Dust Toxic Gas ment SamToxic Gas Sediment Hydrology & Water Quality Air Quality Air Quality Vibration Vibration Sampling & Meteorology Quality Detection Sampling Testing Monitoring Monitoring Detection pling & & Groundwater Monitoring Monitoring Monitoring Testing Analysis Analysis Noise & Vibration Monitoring 121 Noise & Vibration Monitoring Excessive noise and vibration levels in the environment created by industrial, transportation, construction and mining activity is a major cause for concern to both the public and local authorities and can lead to high stress levels in humans and prolonged ill health. www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 Telephone: 872 929 Noise & Vibration Monitoring EN81-102 This mini digital sound level meter has a wide dynamic range and gives virtually instant readings. It is ideal for quick and easy environmental sound level checks. • ‘A’ frequency weighting • Precision 50mm electret condenser microphone • 26mm LCD display with function indicators • Display updates every 0.5 seconds • Min / Max Hold of measured values • “Over” display for out-of-range input • Auto Power Off after 15 minutes of no activity • Low Battery indicator Specification 40 to 130dB Resolution 0.1dB Accuracy ±3.5dB (94dB @ 1KHz) Frequency Range 100Hz~8KHz Function adjustable timer, external calibration control Power 1 x 9V PP3 Alkaline Battery (MLR-61) Dimensions (WxHxD), mm / Weight, g 128 x 51 x 32 / 131 Catalogue No Description EN81-102 Mini Digital Sound Level Meter, supplied with wind muffler and battery Meteorology Range EN81-120 Specification Class 2 Sound Level Meter Microphone & Preamplifier Display Level Range Noise Floor Frequency Weighting IEC 61672-1:2002 (Integrating, Sound Exposure and Sound Level Meters) Type 2 Pre-Polarised ½” (13.2 mm) Electret Free-Field, Electret Condenser Microphone: 20Hz – 8KHz ± 2dB ; –32 dB ± 3 dB re 1V/Pa Back-lit LCD panel (8x1 Characters) Measuring Range: 35-140dB Linear operating range (IEC61672-1): 65dB 3 Measurement Ranges (IEC61672-1): 35-100dB; 55-120dB( Reference Range) 75-140dB Typical ’A’ Weighting <32 dB(A) rms. ‘C’ Weighting <38 dB(C) rms. Calibration Software controlled 91.0 to 120.0 dB (1kHz) in 0.1 dB steps Power Supply Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation). Dimensions (WxHxD), mm Weight,kg 450 x 300 x 50 / 1 Catalogue No Description EN81-120 Digital Sound Level Meter Kit, supplied complete with digital sound pressure level meter, single level calibrator, and carrying case Iinstrument Response Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Training Measurement Parameters ‘A’ and ’C’ to IEC 61672-1:2002 and IEC 60651:1979+A1+A2 20 Hz - 8 kHz (including microphone); 1 Hz - 20 kHz (electrical characteristics) Simultaneous rms. and Peak Lp (Sound Pressure Level), Lmax (maximum Level), Cpeak (Max.Peak Level) Other Displays: Elapsed time, Overload, Battery Life Frequency Range Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring This sound level kit enables the first stage of risk assessment to be made to determine whether there is a noise problem requiring a full evaluation. Action level measurement gives a snapshot of the risk in a particular environment. • Easy to use sound meter • Simple calibration • Instant measurement at the touch of a button • Robust, easy to carry pocket size instruments Toxic Gas Detection Digital Sound Level Meter Kit Type 2 Standards Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Mini Digital Sound Level Meter 122 EN81-130 Safety / Environment Sound Meter Class 1 This system will enable noise levels to be checked in the workplace or in the field and will ensure that employees and others near a noise source is not being subjected to noise levels above dangerous noise levels. This Sound Meter System contains an integrating Class 1 sound level meter capable of measuring sound levels, integrated sound level averages, personal sound exposure levels and dose levels using the supplied dosemeter microphone cable along with the Class 1 calibrator for daily checks on the meter all contained in a handy carrying case. Specification Class 1 Intergrating Sound Level Meter Standards IEC 61672-1:2002 (Integrating, Sound Exposure and Sound Level Meters) IEC 60651:2001 (Sound Level Meters) IEC 60804:2000 (Integrating Function) Microphone & Preamplifier Type 7146A Pre-Polarised ½” (13.2 mm) Free-Field, Electret Condenser Microphone: 20Hz – 20KHz ± 2dB , –32 dB ± 3 dB re 1V/Pa Display Level Range Back-lit LCD panel (8x1 Characters) Alpha-Numeric display for measured results Measuring Range: 35-140dB Linear operating range (IEC61672-1): 65dB 3 Measurement Ranges (IEC61672-1): 5-100, 55-120 (Reference Range) 75-140dB Noise Floor Typical ’A’ Weighting <32 dB(A) rms. ‘C’ Weighting <38 dB(C) rms. Frequency Weighting ‘A’ and ’C’ to IEC 61672-1:2002 and IEC: 60651:2001, Frequency Range 12.5 Hz - 20 kHz (including microphone) 1 Hz - 20 kHz (electrical characteristics) Iinstrument Response Simultaneous rms. and Peak Measurement Parameters Lp (Sound Pressure Level), Leq (Equivalent Sound Level), Lmax (maximum Level), Cpeak (Max. Peak Level), LEpd (Sound Exposure Level), LAE (SingleEvent Sound Exposure Level) Other Displays: Elapsed time, Overload, Battery Life Calibration Software controlled 91.0 to 120.0 dB (1kHz) in 0.1dB steps Power Supply Batteries: 1 x 6LR61 (size PP3), Life: >12 hours (alkaline batteries, continuous operation). Dimensions, mm / Weight, kg 450 x 300 x 50 / 1 Catalogue No Description EN81-130 Safety / Environmental Sound Meter System supplied complete with Class 1 Pocket Integrating Sound / Lux meter, Calibrator with barometer, Dosemeter Plug-in Microphone, and carrying case Training Training Mobile Mobile LaboLaboratories ratories Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Toxic Gas Sediment Air Quality Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Noise & Vibration Monitoring 123 www.wagtechprojects.com [email protected] Telephone: Telephone: +44 (0)1635 872 929 Noise & Vibration Monitoring Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Blast Monitoring Meteorology Toxic Gas Detection EN81-200 Vibration and blast monitoring is conducted where ground vibration as a result of construction or mining activities may cause damage to nearby existing structures and / or disturbance to the surrounding population. Such construction activities may include quarrying, mining, deep dynamic compaction of soils, pile driving, or general construction activities. This compact seismograph is ideal for taking measurements quickly and easily with data interpretation simplified using the supplied software. • Impulse mode for blast monitoring • Continuous mode for piling, rail and road traffic monitoring • Tri-axial geophone sensor • Features: triggering from 0.1 mm/s single range from 0.1 mm/s to 200 mm/s auto record length from 2 to 18 seconds (in impulse mode) • Can trigger and record PPV, acceleration or displacement parameters • Air overpressure from 100 to 140 dB Linear Peak • Memory for about 300 events or 30 days continuous recording • Built in timer function • Instant readout and review of memory event results on LCD • Supplied with RS232 cable and Windows™ based software • Supplied with shoulder bag Specification -10ºC to + 50ºC Power Supply Two Alkaline ‘D’ cells (or external 12 volt supply) Battery Life Up to 20 days continuous monitoring Dimensions, mm / Weight,kg 300 x 250 x 130 / 3.6 Catalogue No Description EN81-200 Blast Monitoring Seismograph EN81-202 Portable Printer Telephone: +44 (0)1635 872 929 Training Training Operating Temperature Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Blast Monitoring Seismograph www.wagtechprojects.com [email protected] 124 Laboratory Analytical Equipment A wide range of specialised analytical and general laboratory equipment is required to analyse fully the quality of water, soil, dust and air in the environment. The following major instruments are included in this section: - UV / Vis Spectrophotometer - Atomic Absorption Spectrophotometer (AAS) - High Performance Liquid Chromatograph (HPLC) - Gas Chromatograph (GC) For information on our full range of laboratory equipment please refer to our General Laboratory Catalogue. Training Training Soil/ SediSoil / Water Laboratory Noise && Laboratory Air / Dust Noise Air Quality Quality Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Monitoring Detection Sampling Testing Laboratories ratories Monitoring pling & & Groundwater Monitoring Detection Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Laboratory Analytical Equipment Air Quality Monitoring 125 125 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Laboratory Air Analytical Quality Equipment Monitoring A Variable or Fixed Bandwidth Spectrophotometer which offers very high performance with fixed optical bandwidth of less than 2nm pharmacopoeia compliant, or variable optical bandwidth of 0.5, 1, 2 and 4nm for high resolution applications. The spectrophotometer’s performance and powerful software are only normally available with much more expensive instruments. Symmetrical double beam system Monochromator Modified Czerny-Turner design using 1200L/mm holographic diffraction grating Detectors Two silicon diode detectors Wavelength Range 190 - 1100nm Wavelength Accuracy 0.5nm Wavelength Reproducibility 0.1nm Optical Bandwidth < 2nm EN91-301; 1nm EN91-302; 0.5, 1, 2, 4nm EN91-303 Stray Light Less than 0.02% at 220nm, NaI; and 0.02% at 340nm, NaNO2 Power Requirements 110-250V, 50 / 60Hz, 170 watts Dimensions, mm (WxHxD) / Weight, kg 635 x 410 x 210 / 33 Catalogue No Description EN91-300 UV and Visible Double Beam Spectrophotometer 190-1100nm. < 2 nm bandwidth, fully symmetrical optics. EN91-301 UV and Visible Double Beam Spectrophotometer 190-1100nm.Bandwidth 0.5, 1, 2 and 4nm, fully symmetrical optics. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Optical System Toxic Gas Detection Specification Meteorology Double Beam Optical System Provides the highest accuracy of measurement coupled with very high stability with time. Both sample and reference beams are provided with the same space facilities, thus catering for the widest possible range of experimental requirements and not limited to just a simple cell in the reference beam. Scans Viewed by Scrolling By scrolling information across the display screen, the effective width of the screen is a massive 430mm. Long scans, plots and other data may be viewed in much more detail, than with other instruments. Powerful Integral Control Rapid operation with ease of use is provided by the powerful software built into the computing system of the instruments. The standard software is remarkably comprehensive but may be expanded, at any time, with additional software modules when required. Integral Memory Scan plots and curves may all be stored, for future use. Integral memory is provided for up to 100 scans, protected by the operator’s personal security codes. Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis UV-Visible Spectrophotometers Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 126 Training Training Soil/ SediSoil / Water Laboratory Noise && Laboratory Air / Dust Noise Air Quality Quality Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Monitoring Detection Sampling Testing Laboratories ratories Monitoring pling & & Groundwater Monitoring Detection Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Laboratory Analytical Equipment Air Quality Monitoring 127 Atomic Absorption Spectrophotometer This Atomic Absorption Spectrophotometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications including: Agriculture, Clinical, Environmental, Food, Metal, Mining and Petrochemical. • Embedded PC system built into the instrument as standard. Windows 7 professional operating system. • Automatic 8 lamp turret controlled and optimized by the AA-Win software. • D2 lamp and Self Reversal background systems fitted as standard. • High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner monochromator. • A universal autosampler is available which is conveniently mounted to the front of instrument. • Absorption and Emission modes are standard as well as peak height, peak area, sequential and manual integration modes. The Instrument is available in three configurations: Note: Catalogue No Description Ask us to quote for installation, commissioning and training. EN91-100 Flame AAS – The Instrument is equipped with a Flame atomiser only. 3 flames are available with the air / acetylene as standard configuration and N2O / acetylene or air / LPG(natural gas) available as an option. EN91-101 Graphite Furnace AAS – The Instrument is equipped with a Graphite Furnace Atomiser only. The Graphite head is fixed into the optical path to maximise performance and eliminate drift. The transversally heated graphite tube is efficiently heated and cooled due to the precision feedback system. EN91-102 Flame and Graphite Furnace AAS – The Instrument is equipped with both Flame and Graphite Furnace Atomiser’s as detailed in the previous description. Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile software. Flame AAS, Atomiser • Air / Acetylene This flame uses a 100mm single slot burner for standard configuration. The high sensitivity (Cu 2ppm > 0.28A) is due to the efficiency of the fixed position glass nebuliser fitted as standard. • N2O / Acetylene The burner for this gas has a 50mm slot and is used to measure elements less prone to ionization such as: Aluminium, Tin, Titanium, Calcium and Vanadium. • Air / Propane (LPG) This flame uses a 3 slot burner and with the low pressure requirement it is also much safer to operate. Due to the lower temperature it is ideal for analysing alkali metals such as Potassium, Sodium and Lithium, especially when used in the Emission mode. • Safety Features: Gas Pressure Monitoring for all gasses, Burner Identification, Flame Sensor, Drain Trap level Sensor, Gas Leak Detector, Safety cut off switch Graphite Furnace AAS, Atomiser • The Transverse head is heated and cooled efficiently due to the feedback system and has been designed to reduce analytical problems normally associated with this type of technique. • Pyrolytically coated graphite tubes are used as standard and are manufactured to improve performance as well as increase the analytical life. • Platform Tubes are supplied as standard and will accept volumes up to 20ul. • Up to 10 heat stages are available. These can be set up and stored in the software. • The graphite furnace tube is cooled efficiently by an optional water circulation system. • Safety Features, Argon Gas Pressure Sensor, Water Flow Sensor, Over Temperature Sensor. www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Laboratory Air Analytical Quality Equipment Monitoring Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Specification 190nm – 900nm Monochromator Czerny-Turner Configuration Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm Wavelength Accuracy ± 0.15nm Wavelength Reproducibility < 0.05nm Resolution 0.2nm ± 0.02nm Baseline Stability 0.005A / 30min Sensitivity (Cu) 2 μg/ml Absorption > 0.28A (flame) Cu < 0.004 μg/ml (flame) Cd < 0.4 x 10-12g (graphite furnace) Cu < 0.7% (Air / Acetylene flame) Ba < 1.0% ( Nitrous oxide / Acetylene flame) Deuterium Arc, Self reversal Characteristic Concentration Cu < 0.02 μg/ml, Ba < 0.15 mg/ml (N2O / Acetylene) Titanium Alloy Nebuliser High-efficiency glass, Acid proof available as an option Detection Limit Repeatability Background Correction Burner Heads Atomization Chamber Meteorology Wavelength Range Corrosion-resistant material Description EN91-100 Flame Atomic Absorption Spectrophotometer(AAS) system with an 8 hollow cathode lamp motorised turret with embedded PC control system complete with pre-loaded M/S Windows 7 operating system and a data coded Air / Acetylene Burner. 110 / 60Hz or 220V / 50Hz AC, 30A, I phase supply EN91-101 Graphite Furnace Atomic Absorption Spectrophotometer(GFAAS) with an 8 hollow cathode lamp motorised turret with embedded PC control system complete with pre-loaded M/S Windows 7 operating system. 110 / 60Hz or 220V / 50Hz AC, 30A, I phase supply EN91-102 Combined Automated Flame & Graphite Furnace Atomic Absorption Spectrophotometer (FGFAAS) with an 8 hollow cathode lamp motorised turret with embedded PC control system complete with pre-loaded M/S Windows 7 operating System and a data coded Air / Acetylene Burner 110 / 60Hz or 220V / 50Hz AC, 30A, I phase supply EN91-103 Universal Auto-Sampler for Flame, Graphite Furnace and Combined Flame and Furnace AAS EN91-104 Nitrous Oxide Burner(coded) 50mm Titanium Alloy Burner Head. EN91-105 Low Temperature Burner Assembly(coded), used only with Natural Gas for trace analysis of Alkali metals.(Sodium, Potassium, Lithium, Barium and Calcium) EN91-106 Air Compressor for use with AAS EN91-107 Water Circulator System EN91-108 Manual Hydride Vapour System for AAS system EN91-109 Acetylene Regulator EN91-110 Compressed Air Regulator EN91-111 Nitrous Oxide Regulator EN91-112 Argon Regulator EN91-113 Extraction System Complete Kit (Fan, Stainless Ducting, Hood, Bends, Brackets) EN91-114 Colour Laser Printer (compatible with embedded PC System.) EN91-115 Single Element Hollow Cathode Lamps (specify elements required) Note: A wide range of single and multi element hollow cathode lamps are available for this instrument. Please specify at time of enquiry or order, which application the instrument is to be used for and a selection of HCL’s will be recommended. Note: Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] Training Training A comprehensive selection of single element 1000ppm standard solutions for AAS are available. Please advise your requirements. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Catalogue No Toxic Gas Detection Depending on the elements to be tested select Compressed Air, Acetylene Gas, Nitrous Oxide, LPG, Hydride Vapour System, Nitrous Oxide Burner Head, and Low Temperature Burner Assembly. 128 EN91-700 Gas Chromatograph Gas Chromatography (GC) with its inherent high sensitivity and high separating power is one of the more commonly used techniques in the analysis of environmental samples. There are two main types of compound that are commonly detected in Environmental Gas Chromatography analysis: Volatile Organic Compounds (VOC) Examples of VOCs are industrial solvents such as carbon tetrachloride, trichloroethene (TCE), trichloroethane (TCA), benzene and toluene. Pesticides Consist of a large group of chemicals that are used in agriculture to control plant and insect infestation. Common classes of pesticides include organophosphates, chlorinated hydrocarbons and carbamates. EN91-700 with EN91-706 This Gas Chromatograph with its patented flow through technology provides excellent chromatographic performance and reliability at realistic prices. Each GC is a dedicated single channel unit with a split/split-less injector and programmable pressure control as standard and a choice of detector options. Flame Ionization (FID), Thermal Conductivity(TCD) and Electron Capture Detectors(ECD) can cover most of the analytical applications in industry today. Manual or automatic gas sampling valves can also be fitted with the autosampler, download software and integration systems this low cost unit can offer the complete integrated package to solve your analytical requirements. Specifications Injectors • Split/splitless injector supplied as standard with all instruments • Split linearity better than 3% up to 200:1 • Injector temperature range 60 - 280˚C • Optional capillary on-column adaptor • Optional gas sampling valve Gas Controls • Electronic pressure control of carrier gas of 0.3 to 50psi, fully programmable with up to five ramps. • Maximum total flow 250ml/min • Detector gas control fixed sinter (apply the specified pressure to the instrument for correct gas flow rates • Optional two channel gas box to allow variability of detector gases EN91-700 series GC in use on site Training Training Laboratory Laboratory Mobile Mobile LaboAnalytical Analytical Laboratories ratories Equipment Equipment Noise Noise& &ViAir// Dust Air Dust Noise & Air Quality Quality Air Quality Air Sampling & bration MoniVibration Vibration Monitoring Monitoring Monitoring Monitoring Monitoring toring Monitoring Soil Soil/ / SediSediSoil/ Soil / Water Toxic Gas Toxic Gas Sediment ment Sam- Hydrology & Water Quality Meteorology Quality Detection Sampling Testing pling & & Groundwater Detection Testing Analysis Analysis Laboratory Analytical Equipment Air Quality Monitoring 129 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Laboratory Air Analytical Quality Equipment Monitoring Description Gas Chromatograph with Flame Ionisation Detector(FID), supplied without column Gas Chromatograph with Thermal Conductivity Detector(TCD), supplied without column Gas Chromatograph with Electron Capture Detector(ECD), supplied without column EN91-700 EN91-702 EN91-704 EN91-706 Autosampler for use with EN91-700 series Gas Chromatographs Note: The Gas Chromatographs are supplied WITHOUT columns which must be ordered separately. Please contact Wagtech Projects for advice on the correct column for your analysis together with other options available for this product. Air/ Noise && Laboratory Laboratory Air / Dust Dust Noise Air Quality Quality Mobile Mobile LaboAir Vibration Analytical Sampling & Sampling & Vibration Analytical Monitoring Laboratories ratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Catalogue No Toxic Gas Detection Control • Built-in keypad, incorporating 2x16 character LCD display • PC control via method download software • Run line control allows the use of most recorders, integrators and PC integration packages Dimensions and Weight • Size 16cm (H) x 41cm (W) x 34cm (D) • Weight 7.5kg, • Power supply: 800VA, 230V/50/60Hz, 115V/50/60Hz Meteorology Detectors • FID, TCD or ECD • Temperature range from 100˚C to 320˚C • FID minimum detectable quantity of 5x10-12 grams of carbon (signal 3x noise level). FID linear range 106 • TCD has 4 tungsten filaments. TCD filament temperatures: 180˚C, 240˚C or 320˚C • ECD minimum detectable quantity of 0.05x10-12 gm of lindane (signal 3x noise level). ECD linear range 103 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Columns Oven • Accommodates all capillary columns up to 7 inch cage, maximum length 120m (5 inch cages required above 60 metres) • Optional packed column capability • Temperature range from 15˚C above ambient to 300˚C • 5 ramp temperature programming • Ramp rates up to 40˚C/min below 200˚C, up to 20˚C above 200˚C • Maximum isothermal temperature 240˚C Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 130 EN91-500 High Performance Liquid Chromatograph (HPLC) A useful analytical technique commonly used by the modern environmental chemist is High Performance Liquid Chromatography (HPLC). Modern pesticides which have been designed and chemically engineered for reduced environmental persistence, have driven the increased use of Liquid Chromatography based solutions. A wide range of options are available to the chemist for HPLC systems depending upon the analysis required. The following is a standard system commonly used for the analysis of pesticides. Please contact Wagtech Projects for further information on other HPLC systems and configurations. Binary - Low Pressure Gradient System This is a low pressure binary gradient forming system. It uses the dual piston pump which has the facility for mixing two solvents for binary gradients and of course may be used in the isocratic mode. Specification Binary Gradient Solvent Pump Flow rate 0.001 to 10L/min in 0.001/min increments Pressure range 0 to 40Mpa over flow range. Flow accuracy <±0.5%. Precision <0.1% RSD Pressure pulsation <±0.5% at 2mL/min Gradient forming Binary low pressure mixing & isocratic high pressure operation. Gradient control High speed proportioning valves. Gradient precision Material in contact with fluids Typically 0.2% RSD at 1mltr/min Ceramic inserts, ruby & sapphire check valves, & PEEK. Specification Variable Wavelength UV/Visible Detector. Optical System Double beam with monochromator Wavelength Range 190-700 nm Wavelength Accuracy ± 1 nm Wavelength Precision ± 0.1 nm, single wavelength mode Optical Bandwidth 8 nm approximately Stray light < .02%, 220 nm Absorbance Range 0.001 to 2 A Noise ± 0.35 x 10-5 A at 230 nm Drift ± 3 x 10-5 A/hour at 230 nm HPLC system is supplied complete with Binary Gradient Solvent Pump, Dual Wavelength UV/Visible Detector, an 8μL x 10mm flowcell, Rheodyne valve fitted with a 20μL loop mounted with the column on the mounting panel, solvent reservoir and pipe organiser, HPLC column (Hyperclone BDS, C18, 5μm, 150 x 4.6mm), HPLC software control system, essential accessories, and installation kit. Catalogue No Description EN91-500 Analytical Binary Gradient HPLC System Complete, excluding PC system EN91-501 PC System with colour printer for data acquisition and control of HPLC EN91-502 Vacuum Degasser, 2 channel for use with HPLC system, to enhance performance by reducing bubble formation in the sample. Training Training Soil/ SediSoil / Water Laboratory Noise && Laboratory Air / Dust Noise Air Quality Quality Toxic Gas ment Sam- Hydrology & Water Quality Mobile Mobile LaboToxic Gas Sediment Air Quality Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Monitoring Detection Sampling Testing Laboratories ratories Monitoring pling & & Groundwater Monitoring Detection Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Laboratory Analytical Equipment Air Quality Monitoring 131 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Mobile Laboratories Meteorology Toxic Gas Detection Air/0/Dust Noise && Laboratory Laboratory Air Dust Noise Mobile LaboMobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical Laboratories ratories tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Training Training 132 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Mobile Laboratories Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Mobile Laboratories 133 Fridge Work space Mobile Testing Laboratory Vehicle Specification • Land Rover Defender 110 • 2.2 litre diesel engine • 6 speed manual gearbox with locking differential • Heavy duty double acting shock absorbers • Meets EU2 Emissions’ targets • 75 litre (16.5 gall) fuel tank • Power assisted steering • Permanent 4-wheel drive • Disc brakes all-round • Michelin 4 x 4 - 7.50x16 tubed radial on / off road tyres • Raised Air Intake • Ground clearance not less than 300mm • Underside protection bar • Front nudge bar (Grill guard) • Basic Tool kit • 1 spare tyre and assembly on rear door • Roof-rack with access ladder • Air-conditioning • Laminated windscreen • Aluminium corrosion resistant body • 5 door with 5 seats in vinyl trim • Vinyl trim, cab and second row seats retained • Supplied with a 36 month or 100,000km International Warranty - whichever comes first Rear Fitting-Out Specification: Specially modified to suit the purpose of a small laboratory. Consists of the following factory fitted components: Sink • Exterior grade ply floor overlaid with washable anti-slip flooring • Sink top and waste with clean and dirty water containers to left hand side of rear saloon. • 12V Fridge/Freezer: Capacity 43litres including 4 litre freezer compartment under laboratory laminated work surface at rear of second row seats. Powered by 12V vehicle electrics. • Lockable cupboard with shelf left of fridge. • Front opening cupboard to right of refrigerator over wheel arch. • Separate intermediate 12V battery with split charge relay. • Socket for external generator ( generator not included) • Rear overhead lighting. Catalogue No Description EN95-100 Mobile Testing Laboratory Optional Accessories Roof rack storage Catalogue No Description EN95-224 Front Mounted Vehicle Winch EN95-226 Long range 127ltr fuel tank EN95-802 Portable Generator, 2 kva, petrol engine Note: Specifications & layout of Mobile Laboratories can be changed to suit your requirements. Please contact us. www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Mobile Laboratories Meteorology Toxic Gas Detection Air/0/Dust Noise && Laboratory Laboratory Air Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Land Rover Defender 110 Training Training 134 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Internal layout Laboratory Unit Mobile Environmental Laboratory Vehicle specification and Accessories: • Land Rover Defender 130 • Single cab chassis • 2.2 litre diesel engine • 6 speed manual gearbox with locking differential • Double wishbone coil spring suspension • Heavy duty double acting shock absorbers • Meets EU2 Emissions’ targets • 75 litre (16.5 gall) fuel tank • Power assisted steering • Permanent 4-wheel drive • Disc brakes all-round • Michelin 4 x 4 - 7.50x16 tubed radial on/off road tyres • Raised Air Intake • Ground clearance not less than 300mm • Underside protection bar • Front nudge bar (Grill guard) • Basic Tool kit • Hi-Lift Jack & Standard Jack mounted on roof as safer option • 1 spare tyre • Roof rack with access ladder • Air-conditioning • Laminated windscreen • Aluminium corrosion resistant body • 2 door cab with 2 seats in Vinyl trim, • Supplied with a 36 month or 100,000km International Warranty - whichever comes first Internal Layout Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Mobile Laboratories 135 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Mobile Laboratories Description EN95-200 Mobile Environmental Laboratory Description EN95-220 Cassette mounted Vanexe room 3.0M x 2.5M with 3 windows, zip up doors & base frame. EN95-222 Roof mounted air conditioning unit for lab area EN95-224 Front Mounted Vehicle Winch EN95-226 Long range 127ltr fuel tank Air/0/Dust Noise && Laboratory Laboratory Air Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring Catalogue No Toxic Gas Detection Optional Accessories Meteorology Catalogue No Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis The vehicle is converted to create a comprehensive Mobile Laboratory Unit with the following features: • Internal dimensions, m; 2.6 (L) x 1.7 (W) x 1.5 (H) • Double skin tropical, insulated roof • Heavy duty, maintenance free batteries • Coated subframe fitted with modular body of insulated laminated panelling with heavy duty light alloy internal and external extrusions. • Fold down rear step to right hand side entrance with window in door. • 12mm Phenolic ply floor overlaid with aluminium tread-plate • 2 x fluorescent lights and switches in saloon • Sliding window to left hand side with security grill • Galvanised roof rack with Access ladder • Extraction fan at rear • External Generator locker at rear with 2.5kva generator • External Locker for clean and dirty water containers • Fridge/Freezer - 156L/16L • Worktop to left hand wall, lockable cupboard over with shelves & stowage • Teal 12V Hand Wash Unit with 5Ltr Tank at left hand centre (Heater operates when engine running) • Corner cupboard with shelf & 4 lockable drawers LH front • Desk area with fold-away swivel chair Training Training Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 136 Mobile Trailer Laboratory Chassis: • Fully galvanised RHS and Angle welded steel construction • PAR type side winding jacks • 2 x 1800kg Peak full beam axle’s c/w auto reverse brakes giving 3500kg gross weight • Hydraulically damped coupling and jockey wheel • 12v lighting (rear lamps fitted into protective light recess) • Under floor chassis mounted spare wheel Body: • Internal dimensions; m:- 6.5 (L) x 2.3 (W) x 2.2 (H) • Overall length 7m to nose cone • Carbofont (GRP laminated polycarbonate) body panels and roof • Fire rating is European classification M1; equivalent to BS476 part 6/7 Class1 • Natural high gloss white body panels with anodised extrusions, capping and trim • Interior walls and ceiling to remain standard white GRP finish • Floor 12mm treated FE ply with Polyflor non slip, anti static (EN1815) acid and alkali resistant safety vinyl • Personnel door fitted (UK) near side with 3 point locking emergency door handle • Folded and welded rigidised aluminium steps with fully adjustable feet, locating guides and locking bolts c/w hand rails Interior Fitting Out: • Laboratory furniture and worktops (see laboratory layout) • Stainless steel sink with fittings • Water heater with holding tank • 12v water pump • Under floor water tank (100 litre) • Roof mounted air conditioning unit • Interior lights and power sockets with wiring to outside generator socket Catalogue No Description EN95-400 Mobile Trailor Laboratory EN95-800 Mobile Generator , 9 KVA chassis mounted Note: Specification & layout can be changed to suit your requirements. Please contact us. Training Training Soil/ SediSoil / Water Laboratory Noise && Air / Dust Laboratory Noise Toxic Gas ment Sam- Hydrology & Water Quality Air Quality Quality Mobile Mobile LaboToxic Gas Sediment Air Sampling & Meteorology Analytical Vibration Analytical Vibration Monitoring Quality Detection Sampling Testing Laboratories ratories Monitoring Monitoring Detection pling & & Groundwater Equipment Monitoring Monitoring Equipment Testing Analysis Analysis Mobile Laboratories 137 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Mobile Laboratories Meteorology Toxic Gas Detection Air/0/Dust Noise && Laboratory Laboratory Air Dust Noise Mobile LaboraAir Quality Quality Mobile Air Vibration Analytical Sampling & Sampling & Vibration Analytical tories Monitoring Laboratories Monitoring Monitoring Monitoring Equipment Equipment Monitoring Monitoring EN95-400 Training Training 138 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Soil / Water Quality Hydrology & Sediment Testing Groundwater Sampling & Analysis Laboratory Layout Single Source Solution... Wagtech Projects can offer advice and guidance on a wide range of equipment used in Environmental Monitoring. Our in-house experts are always available to help you select the correct product either from those listed in the catalogue or by suggesting suitable alternatives. Installation, Commissioning & Training Wagtech Projects supplies equipment all over the world, and the importance of both training and technical support are recognised and as essential in the long term success and sustainability of any project. Through a well established network of regional offices, agents and distributors, we can offer a range of after sales services including installation, commissioning and training on the use and maintenance of the equipment. Equipment Installation and Commissioning A full Installation and Commissioning service is available worldwide from Wagtech Projects through its network of local companies, and fully supported by a team of scientists and technicians from the UK who regularly travel to countries around the world supporting our customers and training our local experts. In addition to this, product training can be given at our dedicated Technical and Training Centre in Thatcham, UK which has a laboratory and training facilities to handle groups of trainees. Following successful commissioning of the equipment, on-going product support is available locally and via email and phone contact with experts in the UK if required. Training The provision of training has been a key service from Wagtech Projects for many years and we continue to offer and expand this facility. The training can either take the form of detailed instruction in the use and maintenance of the equipment we supply or we can organise academic training courses in a variety of separate disciplines in the Agricultural and Environmental Sciences both in the UK and overseas. These courses can be tailored around customer’s specific requirements, and at Wagtech Projects we are flexible enough to be able to accommodate most people’s wishes. Please contact us for more information on any training issues you have in mind. We are always pleased to provide advice on equipment selection, or any technical queries that you may have. We look forward to hearing from you. Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 140 Index A D E B F G C H 141 www.wagtechprojects.com [email protected] Telephone: +44 (0)1635 872 929 Index I R K S L M N O P R Telephone: +44 (0)1635 872 929 www.wagtechprojects.com [email protected] 142 Index T W U V Can’t find what your looking for? Other Wagtech Projects Catalogues are available to download online Alternatively contact us for assistance Telephone: +44 (0)1635 872 929 Email: [email protected] 143 143 www.wagtechprojects.com www.wagtechprojects.com [email protected] [email protected] Telephone: Telephone: +44 +44 (0)1635 (0)1635 872 872 929 929 Terms and Conditions of Business rms and Conditions of Business d Conditions ofConditions Business Terms and of Business Terms and Conditions of Business n and construction Delay:effort Whilst every effort be made to will adhere Orders: Noaccepted order canunless beNo accepted unless a ction 6 Delay: Whilst6every will be made towill adhere order can be all Definition and construction 6 Delay: Whilst every effort be made13 to Orders: adhere No 13 13 Orders: order can be acc shall mean Wagtech Projects to delivery or dates, failure to maintain a delivery necessary have arrangements have been madehave to t nller” Wagtech Projects to delivery dates, delay ordates, failure to maintain a delivery necessary arrangements been made to the “The Seller” shall mean Wagtech Projects to delay delivery delay or failure to maintain a delivery necessary arrangements Definition construction 6orDelay: Whilst effort be made adhere associated company or subsidiary date shall entitle therescind Purchaser to rescind or every satisfaction of the Seller regarding import and1 dany company or subsidiary date shall not entitle the not Purchaser to satisfaction the Sellerto regarding import andthe Seller Limited, anyand associated company or subsidiary date shall not entitle the Purchaser to rescind or willof satisfaction of regard or any duly appointed cancel any order orpayment withhold any payment that and forof the provision ofthe payme “The Seller” shallappointed mean Wagtech Projects toor delivery dates, delay or failure to aexport delivery pointed agent. cancel any order or withhold any that may export licensesexport andmaintain forlicenses the provision payment. thereof or any agent. duly agent. cancel any order withhold anymay payment that may licenses and for pron onditions shall deemed to be be due. 14 to Terms of payment: be deemed to conditions be incorporated of payment: These shall beincorporated deemed to be be incorporated be due. 14 Limited, any associated company ordue. subsidiary date shall not entitle 14 theTerms Purchaser rescind or Terms of payment: s ontract between the Purchaser 7 Minimum Order Value: order The minimum value (a) Prices net and unless other term en the Purchaser and the 7 Minimum Order Value: The minimum value (a) Prices are strictly netare andstrictly other in any contract between thethe Purchaser and the 7 Minimum Order Value:order The order minimum value any (a) Prices areterms strictly net and u thereof or any duly and appointed agent. cancel any or order withhold payment thatunless may e nd shallinbe construed inbe accordance payment in advance or account £250.00 and isfor arranged and agreed in writing by t strued accordance with for payment infor advance or account is £250.00 andisfor have been and agreed in writing by the Seller and shall construedwith in accordance with for payment in advance or account £250.00 and arranged for have been have been arranged and agreed These conditions shall be deemed to be incorporated be due. 1 visions English Law prevailing onprevailing or payment by letter of credit Seller no beright allowed. Thebe right sh Law of prevailing at, on payment of credit £1000.00. candeductions be allowed. The is can the provisions oforEnglishat, Law at, on or by letter payment by £1000.00. letter of credit £1000.00. Seller no deductions Sellercan no deductions allo in any between the Purchaser and the 7The Order Value: The (i) minimum order er has day been any order has accepted theaccepted 8The Cancellation: Seller no shall beMinimum under obligation tovalue request a (i) remittance with an o( accepted by 8 Cancellation: Seller shallThe under obligation reserved to reserved request a(i)remittance with an after thecontract daybeen anythe order has by been by the 8be Cancellation: Sellerno shall be under no obligation reserved to order, request a remit ny disputes which may arise inconstrued relation to aininaccordance to acceptcancellation amendment, or rescission newinvolved, accounts are involved, either to hich maySeller arise in relation tobe awhich to accept or cancellation rescission (ii) where accounts are either to and shall for of payment in of advance or account iswhere £250.00 and for h Seller. Any disputes may arise relation to amendment, a with to accept amendment, cancellation or rescission ofnew (ii) (ii) where new accounts are inv t shall referred to abe single arbitrator (whoprevailing any order or anyany part thereof, but may nevertheless request trade and Banker's references or S red to be athe single arbitrator (who any order or on any part thereof, but may nevertheless request two trade and two Banker's references or to contract shall referred to a Law single arbitrator (who order or any part thereof, but may request two trade and Banker' provisions of English at, or payment by letter ofnevertheless credit £1000.00. tand as not an expert and an arbitrator) in writing to such amendment, or issue Pro-Forma invoices and interest (iii)invoices to charge as anact arbitrator) in agree ininwritingagree to such amendment, or cancellation issue Pro-Forma invoices and (iii) to Pro-Forma charge shall asnot an as expert and not asinan arbitrator) agree incancellation writing such amendment, or issue andint ( after the day any order has been accepted by the 8toCancellation: Thecancellation Seller shall be under no obligation r nce withaccordance the Act 1950 or any whatever terms and anytime balance from time to time outstanding rbitration ActArbitration 1950with or any rescission whateverupon terms and conditions it conditions on any itbalanceon from to time outstanding and the Arbitration Act 1950 or any uponrescission rescission upon whatever terms it and conditions on any balance from time to ti Seller. Any disputes which may arise in relation to a to accept amendment, cancellation or rescission of ( yonmodification on re-enactment thereof for chooses to impose. due to the seller at 5% per annum over and ab re-enactment thereof for chooses to impose. due to the seller at 5% per annum over and above statutory modification on re-enactment thereof for chooses to impose. due to the seller at 5% per ann contract shall be referred to a single arbitrator (who any Items ordercorrectly or any supplied partthe thereof, butfrom may nevertheless e: being in force: the decisions ofthe such arbitrator 9 Returned Goods: Items correctly supplied the Base Rate from time Rate toby time charged bytim Fr the decisions such arbitrator Returned Goods: Items correctly supplied Base Rate time to time Fortis the timeof being in force: decisions of 9such arbitrator 9 Returned Goods: thecharged Base from time to final and binding upon the partiesupon to the against an orderagainst butreturned subsequently as no to Bank S.A./NV. For purchasers enjoying a tradin ng upon the parties to the but as no Bank S.A./NV. For purchasers enjoying a trading shall be final and binding the thean order an order butreturned subsequently returned as no Bank S.A./NV. For purchasers shall act as an expert and notparties as against antoarbitrator) in subsequently agree in writing such amendment, cancellation or ie andbe his fees shall behis borne required or late cancelled to haltupon delivery, account with the Seller, payment must be rece dt in hisdispute fees shall by and longer required or cancelled too to halttoo delivery, account with and the Seller, payment mustwith be received contract inborne dispute feesby shall beAct borne by longer required orlate cancelled too late to halt delivery, account the Seller, payme accordance with the Arbitration 1950 or longer any rescission whatever terms conditions it o y who at of thethe discretion the Seller may at be returned, by the 30 days date. of theIfinvoice ed him.appointed at the discretion Seller may bediscretion returned, atbe by the Seller within 30Seller dayswithin ofby the invoice the party him. who appointed him. atofthe of thereturned, Seller may at the Seller within 30 daysdat of statutory modification on re-enactment thereof for chooses to impose. d ptance: All orders received shall be Purchasers expense, for credit providing the providing payment has not been received by thisreceived time th ers received shall be the Purchasersthe expense, for credit providing the payment been received by this timenot the 1 Acceptance: All orders received shall be the Purchasers expense, for credit the has not payment has been the time being in force: the decisions of such arbitrator 9 Returned Goods: Items correctly supplied t oodinto be placed in accordance with these goods are in an unused condition and in the original Seller reserves, in addition to the rights above ed accordance with these goods are in an unused condition and in the original Seller reserves, in addition to the rights above, the understood to be placed in accordance with these goods are in an unused condition and in the original Seller reserves, in addition to t ndBusiness. Conditions of Business. accepting A restocking charge will be levied this right to suspend further supplies of goods untB shall final andInbinding upon parties to packing. the charge against an for order subsequently returned asright no of Inbe accepting packing. A restocking will be levied for this right suspend further supplies ofto goods until further the Terms and Conditions of Business. In the accepting packing. A restocking charge will bebut levied for to this suspend suppli ary goods delivered by thedelivered Seller theby service. returning anywarehouse, goods to required our warehouse, overdue amount is cleared. vered bycontract the Seller in the service. returning any goods toBefore our overdue amount is to cleared. proprietary goods Seller the be Before service. returning any goods our warehouse, overdue amount is cleared. a dispute and histhe fees shall borne by Before longer ortocancelled too late halt delivery, er shall be deemed to accept the to accept theapproval for such approval such must be from first obtained (b) from Purchasers outside the United med to accept theshall actionfor must beaction first obtained (b) Orders from Purchasers outside the United Purchaser beappointed deemed approval for such action must befrom first from (b) from Purchasers oub the party who him. at the discretion of obtained the Seller may beOrders returned, atOrders cturers Terms and Conditions an identified of our sales/customer service must covered by an and Conditions of Business an identified member of ourmember sales/customer service of our sales/customer Kingdom must Kingdom be covered by be an Irrevocable Letter Manufacturers Terms of andBusiness Conditions of Business an identified member service Kingdom must beIrrevocable covered byLe a 1 Acceptance: Alldirectly orderswith receivedstaff shall be staffdown the Purchasers for credit theprice, been dealing who will take in down event of our inexpense, ofproviding Credit to cover the purchase price, shippingp d Purchaser been dealing directly with had who will take details indown event of our to cover the purchase shipping and as ifhad the Purchaser been dealing directly with staff whodetails will take details event of of Credit our of Credit to cover the purchase beaddition placedtointhe accordance these in unused condition and in the original S ufacturer inManufacturer addition totothe conditions agreeing to the return, you willgoods beare given other additional costs or charges by dition tounderstood the conditions agreeingwith to the return, you willagreeing then be given athen other costs or charges confirmed bycosts aconfirmed the in conditions to the return, you willaan then be given aadditional other additional or charg ed so far Any as applicable. other uniquenumber. goods return number. This goods return Clearing BankMerchant (or a London Merchant r asherein applicable. other unique goods return This goods return (or afor London Bank Terms and Conditions of Business. In accepting packing. A restocking chargeClearing will London beBank levied this rB contained herein so farAny as applicable. Any other unique goods return number. This goods London return London Clearing Bank (or a Lon f business areno excluded and noexcluded variationand ofby number must anyaccompany goods andreturning to the prior written approval of suchapp bo excluded and variation of number anyaccompany goods and returned subject the subject prior approval of bank written by terms of business are nothe variation oftheaccompany numberreturned must any goods returned andtogoods subject tosuch the prior proprietary goods delivered Sellermust service. Before any towritten our warehouse, erms conditions shall bind the seller be included in any sent to us. If you omit us. the theother Seller)arrangements unless other arrangements be tions and shall bindterms the seller beseller included in any paperwork sent to us. Ifinyou omit Seller) have beenotherhave these and conditions shall to bindaccept the be paperwork included any paperwork If you omitunless Seller) unless arrange Purchaser shall be deemed the approval for sent suchtoaction must be first obtainedthe from ( made in writing and signed by aand Director ofby a Director include this number thethis returned will not goods made and agreed in writing. Letters of Credit and signed by made a Director of to include number the returned goods will not goods made and agreed in writing. Letters of Credit unless in writing signed of this to to include number the returned will not made and agreed in writing. Le Manufacturers Terms and Conditions of Business an identified member of our sales/customer service pany with whom the order is placed. be accepted by the seller and will be returned to should allow for part payments and shipments m the order is placed.with whom the order is placed. be accepted by the seller and be willaccepted be returned to seller and will be returned shouldtoallow for part paymentsshould and shipments and paymentsK the company by the allow for part as if the Purchaser had dealing directly with staff who will take down details ofofour sWhere on Approval: Where the SellerWhere has been you at your expense. returned goods must inevent the case orders chemicals shoulo the Seller has you at your expense. All returned must in the case ofinorders including chemicals 2 Goods on Approval: the Seller has you goods atAll your expense. All returned goods must in the including case should of orders including with to thesupply Purchaser supply goods the togoods include all accessories e.g. AC/DC adaptors. Once permit or special aser goods to the include all accessories e.g. AC/DC adaptors. Once permit deck special stowage. agreed withto the Purchaser totosupply to the include all accessories e.g.to AC/DC adaptors. Once deck or special stowage the Manufacturer in addition the conditions agreeing the return, you will or then bedeck given apermit stowage. o er for the Purchaser's approval to approval for the return given,has thebeen goods 15 Delivery and15 delay: All orders for overseas haser's approval prior to approval forother the return has been given,has thebeen goods 15 goods Delivery and delay: All orders for overseas Purchaser forherein the Purchaser's approval prior toAny approval for the return given, the Delivery and delay: All ordeL contained soprior far as applicable. unique goods return number. This goods return nce then if decides the Purchaser he doesdecides must by the seller within 3 weeks. shipmentinare accepted in are accordance the Purchaser he does mustdoes be received bybe thereceived sellermust within weeks. shipment are accepted accordance with the acceptance then ifdecides the Purchaser be3received by the seller within 3 weeks. shipment acceptedwith in acco terms ofmust business are excluded andheno variation of number must accompany any goods returned and s uire the not goods he return them at his 10 Warranty: are only guaranteed to the conditions herein before contained, it being he must return them atgoods his 10 Warranty: Goods are onlyGoods guaranteed to Goods the herein before contained, it being require the he must return them at his 10 Warranty: are only guaranteedconditions to the conditions herein before conta these terms and conditions shall bind the seller be included in any paperwork sent to us. If you omit t pense the Seller in good order and condition extent of the guarantee (if any) given to the Seller understood and agreed that delivery time is th eller into good order and condition extent of the guarantee (if any) given to the Seller understood and agreed that delivery time is the own expense to the Seller in good order and condition extent of the guarantee (if any) given to the Seller understood and agreed that de unless made inwhich writing and which signed a actual Director of actual manufacturers, toother include this number the returned goods willby not 0 days of receipt failing thefailing Purchaser by the all conditions, Seller's of theestimate time which can by hm ipt failing which the Purchaser byby the manufacturers, all conditions, Seller's estimate of theestimate time which it canby have within 30 days of receipt the Purchaser byother the actual manufacturers, all other conditions, Seller's of theittime deemed to have accepted goods within statements warranties, express or implied, goods and ready for dispatc ve accepted the goods within statements warranties,and express or implied, necessary and ready for dispatch. shall be deemed to the have accepted goods within and statements and warranties, express or implied, necessary goods packed and re the company with whom the the order is placed. be accepted by the seller and goods willnecessary bepacked returned topacked s ms Conditions hereof and shallhereof be statutoryonorthe otherwise the part of the Seller areof theThe Theaccept Seller cannot accept responsibility for onsand hereof and shall beConditions statutory or otherwise part of on theor Seller are Seller any responsibility for theGoods Terms and and shall be has statutory otherwise the part Seller are cannot The Seller any cannot accept any ri 2 on Approval: Where the Seller you at on your expense. All returned goods must o payaccordingly. for the same accordingly. hereby excluded. delays in despatch caused throughcaused non-availab ame delays in despatch caused through non-availability bound to pay for the same accordingly. hereby excluded. hereby excluded. delays in despatch thro agreed with the Purchaser to supply goods to11the include all accessoriesofe.g. AC/DCofadaptors. Once p : All are quoted prices ex-warehouse Title: shipping space and/or other causes beyond ices 11 Title: shipping space and/or other beyond 3ex-warehouse Prices: Allare quoted prices are ex-warehouse 11 Title: ofcauses shipping space and/or other Purchaser for the Purchaser's approval prior approval the return been given, the goods 1 xpressly specified toand theare contrary and arecontrary (a) Thesold titleto in the goods the Purchaser the its control. fied to the contrary (a)and Theare title into goods the its has control. unless expressly specified to the (a) Purchaser Thesold titletoinby goods sold for toby the Purchaser by the its control. to alteration without notice. The Seller Seller shall pass the not Purchaser until all sums by 16 Damage Loss in transit ithout notice. The Seller notdoes pass to thenot Purchaser until all must sumstobe 16allDamage and/or Loss in and/or transit and Insurance: acceptance then if the Purchaser decides the seller 3 weeks. s subject to alteration without notice. TheSeller Sellershall he Sellertoshall pass thereceived Purchaser until sums within 16 Damage and/orand LossInsuranc in tran s the right torequire invoice goods atinvoice prices prevailing to the from the Purchaser (whether in (a) the no Seller accepts responsibility for gooc nvoice goods at prices prevailing due to the Seller from theSeller Purchaser in (a) the accepts responsibility for goods reserves the right to atreturn prices prevailing due to (whether Seller from the Purchaser (whether inSeller (a) theno Seller accepts no respo not the goods hegoods must them atdue his 10 Warranty: Goods are only guaranteed to the ate of value despatch plus taxvalue (if added respect goods have or those otherwise) been shipped uninsured and shall not obliged h plus added tax (if added respect those goodsoforthose otherwise) beengoodshave shipped uninsured and shall not be obliged to beand at the date ofvalue despatch (if of respect of or otherwise) have been shipped uninsured shall to nou own expense to the plus Seller in good tax order and condition extent of the guarantee (if any) given to the Seller ate) at appropriate) the appropriate rate. paidIfto the Seller. If defaults thethe Purchaser in paying claim in respect of damage or the loss where, at propriate rate. paid to the Seller. the Purchaser in paying claim in respect of damage or claim loss where, at at the appropriate rate. paid to Seller. Ifdefaults the Purchaser defaults in paying in respect of damage orth within 30todays of receipt which the Purchaser by Seller the actual manufacturers, allrequest, other conditions, S tions: are All are to arefailing any Seller such sum Seller be to take Purchaser's request, insurance arrangements ations subject shall the be entitled to take insurance arrangements have 4 quotations Quotations: All subject quotations subjectany to such sum the any suchshall sum theentitled shall be entitled Purchaser's to take Purchaser's request, insuranceh shall becorrect tocorrect have accepted theaction goods within statements and warranties, express ormade implied, The right is deemed reserved to any to correct such action against the as it may be entitled been than the Seller's ownthe open cn tation. is reserved to any such against the Purchaser itPurchaser may be entitled been other than the other Seller's own open cover confirmation. The right is reserved any suchas action against the Purchaser as it may bemade entitled been made other than Selle rto omission and to re-quote at prices prevailing or in equity without reference with for the insurers time being. re-quote ator prices prevailing in law or in equity without further reference to with insurers forit's theinsurers time being. the Terms and Conditions hereof and shall bein law statutory ortootherwise on the part of the Seller areit's T errors omission and to re-quote at prices prevailing in law or in further equity without further reference toit's with for the time b ate despatch in accordance with Section Unless the Seller is specifically instructed h in of accordance with the Section Purchaser. the Purchaser. the Purchaser. hereby excluded. (b) Unless the (b) Seller is specifically instructed otherwise, at the date ofSection despatch insame accordance with (b) Unless the Seller is specifico bound to pay for the accordingly. d f. A quotation expressed to beexpressed for a fixedto be for (b) The shall the right titleright in before goods will insured only against lossonly or dama expressed to be for a fixed (b)aThe shallPurchaser have the before title in before goods willinbe insured onlybe against loss orbe damage 3 hereof. A quotation fixedPurchaser (b)right The have Purchaser shall have the title goods will insured agai 3 Prices: All quoted prices are ex-warehouse 11 Title: o mains open acceptance by the goods passed, to resell the goods or any in transit for the value acceptance by the open for the goods has the passed, to has resell thegoods goods or passed, any in or transit C.I.F value plus 10%. pricefor remains acceptance by the the has to resell the goods any for the inC.I.F transit forplus the 10%. C.I.F value plu unless expressly to in the contrary are (a) The title in Seller goods sold theunder Purchaser by the er within the in period stated the quotation part thereof shall paythe tobut the Seller the (c) Allthe claims under theclaims Seller's insurance musi eriod stated the quotation thereofand but shall pay tobut the Seller proceeds (c) All to claims Seller's insurance must be the Seller's Purchaser within theinspecified period stated thepart quotation part thereof shall pay toproceeds the the proceeds (c) All under subject to without notice. The Seller not pass to the Purchaser all sums period is stated, within days of the date sale or such thereof asSeller mayto beshall necessary tobe necessary notified in Seller writing to the 45 Seller days1 ed, within of alteration the date of or suchof part thereof aspart may beornecessary notified intowriting tountil the within 45 dayswithin from or,30 if days no period is30 stated, within 30 days ofsale the date of sale such part thereof as may notified inSeller writing to the uotation ofright when theinvoice quotation paytoallthe sums duepay to all the Seller from Purchaser point(whether of discharge. ective of when thethe quotation pay all prices sums due Seller from the Purchaser point discharge. ofirrespective the quotation irrespective of when the quotation sums due to the Seller from the Purchaser point reserves to goods at prevailing due to the Seller from theof Purchaser in of discharge. ( ed by the Purchaser. payment shall the proceeds ofthe proceeds 17 Import Licenses: Where applicable, the app haser. and until such payment shall hold of 17 Import Where applicable, the is received by of thedespatch Purchaser. plus value and the untilproceeds suchhold payment shall hold of Licenses: 17 Import Licenses: Where at the date added tax and (if until such respect of those goods or otherwise) have been s ry:effort Whilst every is made adhere to to sale trust forsale theon Seller. Purchaser's order must specify the number, da y made effort to Whilst adhere to to sale on trust theonSeller. Purchaser's order must specify the number, date of 5isDelivery: every effort is made adhere to for trust for the Seller. Purchaser's order must specify appropriate) at the appropriate rate. paid to the Seller. If the Purchaser defaults in paying dates, no liability whatsoever canwhatsoever be (c) Notwithstanding subclause (a) of this clause, expiry and valueexpiry of theand Import It shallc ity whatsoever can be no liability (c)be Notwithstanding subclause(c) (a)Notwithstanding of this clause, the and value of the Import License. Itvalue shallLicense. be delivery dates, can subclause (a)the of thisexpiry clause, the of the Import 4 Quotations: All quotations arehowsoever subject tobe goods any such the shall be entitled to take d for lateness ofhowsoever non-delivery howsoever be at the risk fromsum the time the Purchaser's responsibility toresponsibility obtain all nectP of non-delivery goods shall at the shall Purchaser's riskPurchaser's frombe the thethe Purchaser's responsibility to obtain all necessary accepted for lateness of non-delivery goods shall at time the Purchaser's riskSeller from time the Purchaser's Deliveries offered ex-stock areright subject to are subject they delivered toare thedelivered Purchaser. Import ed ex-stock areDeliveries subject to they the Purchaser. Import Licenses. confirmation. The is reserved toare correct anytoare such against the Purchaser as it Licenses. may beImport entitled b arising. offered ex-stock todelivered they to action the Purchaser. Licenses. eing unsold the of receipt of 12 Dangerous and poisons: Chemicals 18 Bank Charges, Documentation, Feew the date of at receipt of the 12of Dangerous chemicals and chemicals poisons: Chemicals 18 Bank Charges, Special Documentation, Fees Special Docu goods being unsold at and the date of receipt the 12 Dangerous chemicals and poisons:without Chemicals Bank Charges, errors or date omission tothe re-quote at prices prevailing in law or in equity further reference to18Special ers order. The seller reserves right to should handled andtrained used only by trained Duties: Allbank consular andAll bank charges, seller reserves right be handled andbe used only by and Duties: Alland consular and import Purchasers order. The the seller reserves theshould right to should be handled used only by trained and charges, Duties: consular andimp ba( at the the date oftodespatch in accordance with Section theand Purchaser. or delivery unless agreed and personnel or under appropriate No supervision. and customs and anyfrom taxes from ess otherwise agreed and unless personnel appropriate supervision. Nosupervision. andNo customs duties and anyduties taxes arising orarising charge for otherwise delivery otherwise agreed and or under personnel or under appropriate and customs duties and any ta A expressed to be for a fixed (b)for The Purchaser the right before in andthe g n writing inhereof. respect of quotation individual transactions. responsibility orresponsibility liability whatsoever is accepted for isshall bycontract virtue ofand thetitle contract its settlement pect of 3 individual transactions. liability whatsoever is accepted by have virtue of the its settlement are the stated in writing in respect of individual responsibility transactions. or or liability whatsoever accepted for by virtue of contract andar it open for acceptance the the has passed, to resell goods or Purchaser any for anyprice loss orremains damage in transit arising out loss ofuse the usethe or storage, handling liability of unless the specifically agri damage in transit loss arisingany outloss of the storage, orstorage, handling liability of thethe Purchaser specifically Liability for any loss or damage in transitanyby any arising out goods of use or handling liability ofunless theagreed Purchaser unless ver caused is not under anyiscircumstances of chemicals howsoever caused. Thethereof sale of poisons in Seller. writing byproceeds theinSeller. ot under any circumstances of in chemicals howsoever caused. sale ofhowsoever poisons by the Purchaser within the period stated the quotation part but shall to the Seller the ( howsoever caused not under any circumstances of The chemicals caused. The saleinpay ofwriting poisons writing by the Seller. d to theor, Seller. isthe regulated by and the Pharmacy Poisons is regulated Pharmacy Poisons Act admitted the Seller. is regulated byand thesale Pharmacy and part Poisons Act if no to period is stated, within 30 days of by the date of or Act such thereof as may be necessary to n 1933, the Poisons Listthe and theand Poison and 1933, the Poisons List and the1933, Poison Rules Poisons List Rules and the Poison Rules and of the quotation irrespective of when the quotation pay all sums due to the Seller from the Purchaser p amending fromlaid time time laidtime or made amending legislation fromlegislation timeamending to time or to made legislation from to time laid or made is received by the Purchaser. and until such payment shall hold the proceeds of 1 by any competent authority. by any competent authority. by any competent authority. 5 Delivery: Whilst every effort is made to adhere to delivery dates, no liability whatsoever can be accepted for lateness of non-delivery howsoever arising. Deliveries offered ex-stock are subject to goods being unsold at the date of receipt of the Purchasers order. The reserves right to Telephone: +44seller (0)1635 872the 929 charge for delivery unless otherwise agreed and sale on trust for the Seller. (c) Notwithstanding subclause (a) of this clause, the goods shall be at the Purchaser's risk from the time they are delivered to the Purchaser. 12 Dangerous chemicals and poisons: Chemicals www.wagtechprojects.com should be handled and used only by trained [email protected] personnel or under appropriate supervision. No 144 P e t I 1 a a International Network Office, Agents and Distributors Wagtech Projects has its own offices, authorised dealers or distributors in many countries throughout the world. All of them have the necessary skills and relevant experience to provide you with a wide range of services from providing equipment, spares, consumables and reagents to full after sales service and technical support. Contact us for details of your nearest appointed agent or distributor. C 2012 Wagtech Projects This catalogue is a copyright and no part of it may be produced, photocopied or stored in any data retrieval system without permission. Catalogue Developed and Produced by Wagtech Projects. Designed by Guy Wintgens. Every effort has been made to ensure that the descriptions given in this catalogue were correct at the time of going to press, but we accept no liability for any error and the specifications are subject to change without prior notice.