Product information
Transcription
Product information
Fitting in OASIS plus Product information ICOS 105 BTE DM VC ICOS 105 BTE DM To benefit from the unique features in ICOS, OASIS plus introduces an enhanced workflow. The Lifestyle Profile: provides a structured framework for identifying the specific communi- cation needs of your client. It is this information that drives the automatic behaviour of ICOS. ICOS: The first hearing system with Personalized Audio NavigationTM Client Profile • Sound CheckTM: offers the tools that are necessary for verifying the initial fit of ICOS. The combination of individual needs and preferences with audiometric data drives the automatic allocation of programs and the behaviour of the adaptive settings in ICOS. • Automatic Program Allocation: OASIS plus defines what user programs have to be assigned to cover the client‘s lifestyle priorities. • Global Fine-Tuning: Master tools for optimizing the response for all programs simultaneously. • Environment Specific Controls: A dedicated set of controls offered to specifically optimize different environments and programs. • ICOS Tracker: Not only can the important information about the clients use of ICOS be viewed but OASIS plus will offer fine-tuning suggestions based on the accumulated data. AudioMatics The adaptive features in ICOS are combined as needed to maximize performance in the recognized environment. • • • • • • • • • • All ICOS System can be operated with the optional Bernafon Remote Control RC-S. REF. 160-02-310-00 For patients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered. Custom Remote Control Audio Navigation ProgramTM 3 freely configurable listening programs Dedicated DAI/FM listening program Multi-Dimensional Directionality Adaptive Noise Reduction in 8 bands Audio RecognitionTM with 4 different monitors Soft Noise Management Adaptive Feedback Cancellation OpenFitTM 7-channel digital signal processing Apart from advanced fine-tuning tools, ICOS offers an in-depth insight into the use and behavior of the hearing system while worn by your client. It provides a solid foundation for clear and accurate recommendations for maximal optimization. REF. 160-02-320-00 Innovative Hearing Solutions www.bernafon.com Quality System DS/EN ISO 9001 DS/EN ISO 13485 Bernafon Australia Pty. Ltd. Unit 12, 97 Castlemaine Street Milton QLD 4064 Australia Freecall 1800 809 111 Phone +61 (0)7 3250 0300 Fax +61 (0)7 3250 0372 www.bernafon.com.au Bernafon New Zealand Ltd. Level 1, Building F 27-29 William Pickering Drive Albany, Auckland New Zealand Phone +64 9 920 42 40 Fax +64 9 920 42 43 www.bernafon.co.nz 7.07/BAG/951-18-010-00/subject to change Manufacturer: Bernafon UK Cadzow Industrial Estate Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 28 59 68 Fax +44 1698 42 14 56 www.bernafon.co.uk Frequency (Hz) ICOS 105 BTE DM VC A compact BTE with an adaptive directional microphone system, a size 13 battery and rotary volume control, suitable for mild to severe hearing losses. Optimization • ICOS Tracker (Data logging) with fine-tune proposals • Sound CheckTM • 7-Channel TriQualizer™ Bernafon AG Morgenstrasse 131 3018 Bern Switzerland Phone + 41 (0)31 998 15 15 Fax + 41 (0)31 998 15 90 105 BTE DM VC/105 BTE DM • Lifestyle Profile • Clinical Profile Remote Control Standard Remote Control dB HL • Innovative Hearing Solutions ICOS 105 BTE DM A compact BTE with an adaptive directional microphone system, size 13 battery, suitable for mild to severe hearing losses. Frequency responses ICOS information ICOS BTE Gain Output 105 BTE DM VC 105 BTE DM IEC 60118-7 IEC 60118-0 IEC 60118-7 IEC 60118-0 Current Distor tion General Information Additional Information (Ears.) Gain / dB 140 90 130 80 120 70 110 60 100 50 Output / dB SPL ICOS 105 BTE DM VC ICOS 105 BTE DM Gain / dB 140 90 130 80 120 70 110 60 100 50 (2cc) OSPL 90, Peak dB SPL 123 127 123 127 OSPL 90 , 1600 Hz dB SPL 112 121 112 121 HFA OSPL 90, ANSI dB SPL 113 –– 113 –– Full-On Gain, Peak dB 60 63 60 63 Full-On Gain, 1600 Hz dB 52 58 52 58 HFA Full-On Gain, ANSI dB 53 –– 53 –– 90 40 90 40 Reference Test Gain, IEC dB 36 44 36 44 80 30 80 30 20 70 dB 35 –– 35 –– Quiescent Current mA 1.2 1.2 1.2 1.2 Operating Current, IEC mA 1.2 1.2 1.2 1.2 Operating Current, ANSI mA 1.2 –– 1.2 –– 13 13 Battery type 1) (2cc) Output / dB SPL IEC 60118-0 Earsimulator (IEC 60711) Reference Test Gain, ANSI (Ears.) IEC 60118-7 2cc Coupler (IEC 60126) 500/800/1600 Hz typ., IEC % <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 500/800/1600 Hz typ., ANSI % <1 / <1 / <1 –– <1 / <1 / <1 –– Frequency Range, ANSI Hz 100 – 5800 100 – 5800 Equiv. Input Noise, IEC/ ANSI 1) 15/13 15/13 Telecoil 1 mA/m 1600 Hz, IEC dB SPL dB 83 92 83 92 Telecoil HFA SPLITS, ANSI dB SPL 96 –– 96 –– yes yes Remote Control Reception Earhooks 8 dB (std.), 0 dB (opt.) 8 dB (std.), 0 dB (opt.) Childrens Earhooks 8 dB (opt.), 0 dB (opt.) 8 dB (opt.), 0 dB (opt.) SPIRA Thin Sound Tube 0.9 optional optional Programmable telecoil yes yes Push button yes yes FM communication yes yes DAI yes yes Volume control yes –– 70 250 500 1k 1k6 2k 2k5 4k 8k Output OSPL 90 Full-On Gain 250 500 Frequency/Hz 1k DAI/FM Adapters FMA3 Adapter DAI3 Adapter For FM communication REF. 399-50-570-00 systems only For connection to Hi-Fi, TV set, PC, etc. REF. 399-50-580-00 ICOS BTE Color Range Style & Design Technical data measured with expansion, corresponding to Soft Noise Management level 3. blue white grey platinum gold anthracite black Young & Fun ICOS is programmed with OASIS plus, Version 6.0 or later – a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 2.0 or NOAH 3.0 with a Hi-Pro or a NOAHlinkTM is required. Programming adapter Programming adapter REF. 390-01-151-00 Traditional & Classic green yellow rose beige brown blue Programming cables Nr. 2, NEW STANDARD (HiPro) Blue, left Red, right REF. 384-20-033-00 REF. 384-20-032-00 Note: Always use new batteries for programming. Nr. 2, NEW STANDARD (NOAHlink) Blue, left Red, right 4k Frequency/Hz All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. All measurements are based on earhook without filter. Adapters and cables 1k6 2k 2k5 REF. 384-20-035-00 REF. 384-20-034-00 grey brown graphite 8k 20 Frequency responses ICOS information ICOS BTE Gain Output 105 BTE DM VC 105 BTE DM IEC 60118-7 IEC 60118-0 IEC 60118-7 IEC 60118-0 Current Distor tion General Information Additional Information (Ears.) Gain / dB 140 90 130 80 120 70 110 60 100 50 Output / dB SPL ICOS 105 BTE DM VC ICOS 105 BTE DM Gain / dB 140 90 130 80 120 70 110 60 100 50 (2cc) OSPL 90, Peak dB SPL 123 127 123 127 OSPL 90 , 1600 Hz dB SPL 112 121 112 121 HFA OSPL 90, ANSI dB SPL 113 –– 113 –– Full-On Gain, Peak dB 60 63 60 63 Full-On Gain, 1600 Hz dB 52 58 52 58 HFA Full-On Gain, ANSI dB 53 –– 53 –– 90 40 90 40 Reference Test Gain, IEC dB 36 44 36 44 80 30 80 30 20 70 dB 35 –– 35 –– Quiescent Current mA 1.2 1.2 1.2 1.2 Operating Current, IEC mA 1.2 1.2 1.2 1.2 Operating Current, ANSI mA 1.2 –– 1.2 –– 13 13 Battery type 1) (2cc) Output / dB SPL IEC 60118-0 Earsimulator (IEC 60711) Reference Test Gain, ANSI (Ears.) IEC 60118-7 2cc Coupler (IEC 60126) 500/800/1600 Hz typ., IEC % <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 500/800/1600 Hz typ., ANSI % <1 / <1 / <1 –– <1 / <1 / <1 –– Frequency Range, ANSI Hz 100 – 5800 100 – 5800 Equiv. Input Noise, IEC/ ANSI 1) 15/13 15/13 Telecoil 1 mA/m 1600 Hz, IEC dB SPL dB 83 92 83 92 Telecoil HFA SPLITS, ANSI dB SPL 96 –– 96 –– yes yes Remote Control Reception Earhooks 8 dB (std.), 0 dB (opt.) 8 dB (std.), 0 dB (opt.) Childrens Earhooks 8 dB (opt.), 0 dB (opt.) 8 dB (opt.), 0 dB (opt.) SPIRA Thin Sound Tube 0.9 optional optional Programmable telecoil yes yes Push button yes yes FM communication yes yes DAI yes yes Volume control yes –– 70 250 500 1k 1k6 2k 2k5 4k 8k Output OSPL 90 Full-On Gain 250 500 Frequency/Hz 1k DAI/FM Adapters FMA3 Adapter DAI3 Adapter For FM communication REF. 399-50-570-00 systems only For connection to Hi-Fi, TV set, PC, etc. REF. 399-50-580-00 ICOS BTE Color Range Style & Design Technical data measured with expansion, corresponding to Soft Noise Management level 3. blue white grey platinum gold anthracite black Young & Fun ICOS is programmed with OASIS plus, Version 6.0 or later – a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 2.0 or NOAH 3.0 with a Hi-Pro or a NOAHlinkTM is required. Programming adapter Programming adapter REF. 390-01-151-00 Traditional & Classic green yellow rose beige brown blue Programming cables Nr. 2, NEW STANDARD (HiPro) Blue, left Red, right REF. 384-20-033-00 REF. 384-20-032-00 Note: Always use new batteries for programming. Nr. 2, NEW STANDARD (NOAHlink) Blue, left Red, right 4k Frequency/Hz All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. All measurements are based on earhook without filter. Adapters and cables 1k6 2k 2k5 REF. 384-20-035-00 REF. 384-20-034-00 grey brown graphite 8k 20 Fitting in OASIS plus Product information ICOS 105 BTE DM VC ICOS 105 BTE DM To benefit from the unique features in ICOS, OASIS plus introduces an enhanced workflow. The Lifestyle Profile: provides a structured framework for identifying the specific communi- cation needs of your client. It is this information that drives the automatic behaviour of ICOS. ICOS: The first hearing system with Personalized Audio NavigationTM Client Profile • Sound CheckTM: offers the tools that are necessary for verifying the initial fit of ICOS. The combination of individual needs and preferences with audiometric data drives the automatic allocation of programs and the behaviour of the adaptive settings in ICOS. • Automatic Program Allocation: OASIS plus defines what user programs have to be assigned to cover the client‘s lifestyle priorities. • Global Fine-Tuning: Master tools for optimizing the response for all programs simultaneously. • Environment Specific Controls: A dedicated set of controls offered to specifically optimize different environments and programs. • ICOS Tracker: Not only can the important information about the clients use of ICOS be viewed but OASIS plus will offer fine-tuning suggestions based on the accumulated data. AudioMatics The adaptive features in ICOS are combined as needed to maximize performance in the recognized environment. • • • • • • • • • • All ICOS System can be operated with the optional Bernafon Remote Control RC-S. REF. 160-02-310-00 For patients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered. Custom Remote Control Audio Navigation ProgramTM 3 freely configurable listening programs Dedicated DAI/FM listening program Multi-Dimensional Directionality Adaptive Noise Reduction in 8 bands Audio RecognitionTM with 4 different monitors Soft Noise Management Adaptive Feedback Cancellation OpenFitTM 7-channel digital signal processing Apart from advanced fine-tuning tools, ICOS offers an in-depth insight into the use and behavior of the hearing system while worn by your client. It provides a solid foundation for clear and accurate recommendations for maximal optimization. REF. 160-02-320-00 Innovative Hearing Solutions www.bernafon.com Quality System DS/EN ISO 9001 DS/EN ISO 13485 Bernafon Australia Pty. Ltd. Unit 12, 97 Castlemaine Street Milton QLD 4064 Australia Freecall 1800 809 111 Phone +61 (0)7 3250 0300 Fax +61 (0)7 3250 0372 www.bernafon.com.au Bernafon New Zealand Ltd. Level 1, Building F 27-29 William Pickering Drive Albany, Auckland New Zealand Phone +64 9 920 42 40 Fax +64 9 920 42 43 www.bernafon.co.nz 7.07/BAG/951-18-010-00/subject to change Manufacturer: Bernafon UK Cadzow Industrial Estate Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 28 59 68 Fax +44 1698 42 14 56 www.bernafon.co.uk Frequency (Hz) ICOS 105 BTE DM VC A compact BTE with an adaptive directional microphone system, a size 13 battery and rotary volume control, suitable for mild to severe hearing losses. Optimization • ICOS Tracker (Data logging) with fine-tune proposals • Sound CheckTM • 7-Channel TriQualizer™ Bernafon AG Morgenstrasse 131 3018 Bern Switzerland Phone + 41 (0)31 998 15 15 Fax + 41 (0)31 998 15 90 105 BTE DM VC/105 BTE DM • Lifestyle Profile • Clinical Profile Remote Control Standard Remote Control dB HL • Innovative Hearing Solutions ICOS 105 BTE DM A compact BTE with an adaptive directional microphone system, size 13 battery, suitable for mild to severe hearing losses. Product Information ICOS 106 BTE DM ICOS – Lifestyle Driven Technology dB HL ICOS, the only premium hearing instrument family offering Lifestyle Profile technology, now introduces the micro BTE: ICOS 106 BTE DM. 106 BTE DM Cl Fit ient B tin g T ased ools -D l P im ro ens c e io ss nal ing Lifestyle Driven Technology n atio v ig Na o di ram Au rog P Styles and Colors le e Profi st y l Life ti ul M i g na S Innovative Technology for maximized hearing benefits • • • • • Micro size BTE housing 312 size Battery Lifestyle Profile Audio Navigation Program Multi-Dimensional Signal Processing – 7 channels – Multi-Dimensional Directionality in 4 bands – Adaptive Noise Reduction in 8 bands – Soft Noise Management – Adaptive Feedback Cancellation – OpenFit – Adaptive Signal Unification • Client based Fitting Tools – 3 freely configurable listening programs (choice out of 11) – ICOS Tracker Data logging system • Styles and Colors – 10 stylish BTE colors – Compatible with SPIRA flex Sound Tube System – Optional Remote Control – DAI compatibility – Mute function Innovative Hearing Solutions Frequency (Hz) ICOS 106 BTE DM A fully programmable digital micro BTE instrument, with an adaptive directional microphone system, a size 312 battery, suitable for mild to moderate hearing losses. ICOS Information ICOS 106 BTE DM Additional Information Current Gain Output SPIRA flex Tube 0.9 IEC 60118-7 ANSI S3.22 (2cc) IEC 60118-0 IEC 60118-0 (Ears.) IEC 60118-7 ANSI S3.22 (2cc) 121 126 (Ears.) OSPL 90, Peak dB SPL 117 123 OSPL 90, 1600 Hz dB SPL 102 112 108 118 HFA OSPL 90 dB SPL 108 –– 113 –– Full-On Gain, Peak dB 47 54 50 57 Full-On Gain, 1600 Hz dB 36 45 41 51 HFA Full-On Gain dB 41 –– 46 –– Reference Test Gain dB 30 37 36 42 Quiescent Current mA 1.2 1.2 1.2 1.2 Operating Current mA 1.3 1.2 1.3 1.2 Battery type 312 Distortion 500/800/1600 Hz typ. % <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 Frequency Range Hz 100–5000 –– 100–5300 –– dB 16 19 12 16 Equiv. Input Noise 1) Remote Control reception yes Push button yes DAI yes Volume control 1) SPIRA flex Tube 1.3 by Remote Control Technical data measured with expansion, corresponding to Soft Noise Management level 3. All measurements are made according to IEC 60118 and ANSI S3.22-2003 with SPIRA flex tubes #2. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. Frequency Response IEC 60118-7 2cc Coupler (IEC 60318-5)1) Output / dB SPL IEC 60118-0 Earsimulator (IEC 60711) Gain / dB Output / dB SPL Gain / dB 140 90 130 80 120 70 60 110 60 100 50 100 50 90 40 90 40 80 30 80 30 20 70 140 90 130 80 120 70 110 70 250 500 1k 1k6 2k 2k5 4k ICOS 106 BTE DM Output OSPL 90 Full-On Gain 20 250 8k 500 Frequency / Hz 1k 1k6 2k 2k5 Frequency / Hz Measurements with Tube 1.3 mm Measurements with Tube 0.9 mm 1) Identical to coupler described in withdrawn standard IEC 60126 SPIRA flex Sound Tube System SPIRA flex Sound Tube System for more cosmetic and open fitting solutions. Please refer to the SPIRA flex Product Brochure REF. 951-18-710-00 or the SPIRA flex Product Information REF. 951-18-610-00 SPIRA flex Master Fitting Kit containing all SPIRA flex components REF. 890-80-060-00 4k 8k Quick Fitting Guide Different acoustic options result in different benefits Open Dome short vent length < 3 mm Tulip Dome Custom Tip Canal Mold vent length 10 mm SPIRA flex 0.9 SPIRA flex 1.3 Maximum Fitting Range Minimum Feedback Risk Maximum Cosmetics Minimum Occlusion Suggested maximum fittings with different acoustic combinations SPIRA flex tube 1.3 dB HL dB HL SPIRA flex tube 0.9 Frequency / Hz Frequency / Hz with Open Dome with Tulip Dome with Tulip Dome with Canal Mold, large vent with Custom Tip or Canal Mold with Canal Mold, no vent ICOS 106 BTE DM Color Range Style & Design titan platinum gold anthracite black grey brown beige brown graphite Traditional & Classic grey Cables and Adapters ICOS 106 BTE DM is programmed with OASIS plus, Version 8.0 or later – a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 2.0 or NOAH 3.0 with a Hi-Pro or a NOAHlink is required. Programming cables Programming Adapter Nr. 2, NEW STANDARD (HiPro) Programming adapter REF. 399-50-640-00 Blue, left REF. 384-20-033-00 Red, right REF. 384-20-032-00 Nr. 2, NEW STANDARD (NOAHlink) DAI 4 Adapter Blue, left REF. 384-20-035-00 For connection to Hi-Fi, TV set, PC, etc. REF. 399-50-521-00 Red, right REF. 384-20-034-00 Note: Always use new batteries for programming. Fitting in OASIS plus ICOS Tracker Data logging The enhanced ICOS Tracker Data logging system records a wealth of operational statistics encompassing: • Client usage: including total wearing time and average daily use • Listening environments: representing which environments the client had worn their instruments • User adjustments: including program and volume changes, and the level of changes • Feedback monitoring: a feature unique to ICOS Tracker, which monitors the activity of the Adaptive Feedback Canceller, and the associated feedback risk • Fine-tuning recommendations: which can be instantly implemented to optimize the fitting, ensuring efficient and accurate follow up and reducing the number of fine tuning sessions Remote Control All ICOS systems can be operated with the optional Bernafon Remote Control RC-S. Standard Remote Control REF. 160-02-310-00 For patients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered. Custom Remote Control REF. 160-02-320-00 Innovative Hearing Solutions Bernafon AG Morgenstrasse 131 3018 Bern Switzerland Phone + 41 (0)31 998 15 15 Fax + 41 (0)31 998 15 90 www.bernafon.com Quality System DS/EN ISO 9001 DS/EN ISO 13485 Bernafon UK Cadzow Industrial Estate Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 28 59 68 Fax +44 1698 42 14 56 www.bernafon.co.uk Bernafon Australia Pty. Ltd. 512 Wickham Street Fortitude Valley QLD 4006 Australia Freecall 1800 809 111 Phone +61 (0)7 3250 0300 Fax +61 (0)7 3252 2048 www.bernafon.com.au Bernafon New Zealand Ltd. Level 1, Building F 27-29 William Pickering Drive Albany, Auckland New Zealand Phone +64 (0)9 920 42 40 Fax +64 (0)9 920 42 43 www.bernafon.co.nz 09.07/BAG/951-19-210-00/subject to change Manufacturer: U A A IEC 60118-7 2cc Coupler (IEC 60126) Output/dB SPL IEC 60118-0 Earsimulator (IEC 60711) Gain / dB 120 70 110 60 Output / dB SPL ICOS 205 ITE DM VC Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 50 90 40 100 50 80 30 90 40 70 20 80 30 60 10 70 20 0 60 250 500 1k 1k6 2k 2k5 4k 8k 250 500 Frequency/Hz 1k 1k6 2k 2k5 4k The Lifestyle Profile: provides a structured framework for identifying the specific communi- cation needs of your client. It is this information that drives the automatic behaviour of ICOS. ICOS 205 ITE DM VC ICOS 315 ITC DM VC ICOS 305 ITC DM ICOS 415 MC DM ICOS 410 MC / ICOS 400 CIC • Sound CheckTM: offers the tools that are necessary for verifying the initial fit of ICOS. ICOS: The first hearing system with Personalized Audio NavigationTM • Automatic Program Allocation: OASIS plus defines what user programs have to be assigned to cover the client‘s lifestyle priorities. Client Profile To benefit from the unique features in ICOS, OASIS plus introduces an enhanced workflow. 100 50 8k 10 • • Global Fine-Tuning: Master tools for optimizing the response for all programs simultaneously. Frequency/Hz • Environment Specific Controls: A dedicated set of controls offered to specifically optimize different environments and programs. Output/dB SPL Gain / dB 120 70 110 60 100 50 Output / dB SPL ICOS 315 ITC DM VC Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 100 50 90 40 80 30 90 40 70 20 80 30 60 10 70 20 50 0 60 10 250 500 1k 1k6 2k 2k5 4k 8k 250 Product information Fitting in OASIS plus 500 Frequency/Hz 1k 1k6 2k 2k5 4k 8k • ICOS Tracker: Not only can the important information about the clients use of ICOS be viewed but OASIS plus will offer fine-tuning suggestions based on the accumulated data. • Lifestyle Profile • Clinical Profile AudioMatics The adaptive features in ICOS are combined as needed to maximize performance in the recognized environment. • • • • • • • • • • All ICOS System can be operated with the optional Bernafon Remote Control RC-S. REF. 160-02-310-00 For patients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered. Custom Remote Control REF. 160-02-320-00 Frequency/Hz Audio Navigation ProgramTM 3 freely configurable listening programs Additional dedicated AutoTelephone program Multi-Dimensional Directionality Adaptive Noise Reduction in 8 bands Audio RecognitionTM with 4 different monitors Soft Noise Management Adaptive Feedback Cancellation OpenFitTM 7-channel digital signal processing Optimization Apart from advanced fine-tuning tools, ICOS offers an in-depth insight into the use and behavior of the hearing system while worn by your client. It provides a solid foundation for clear and accurate recommendations for maximal optimization. Gain / dB 120 70 110 60 100 50 90 40 80 Output / dB SPL ICOS 305 ITC DM Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 Manufacturer: 110 60 Bernafon AG Morgenstrasse 131 3018 Bern Switzerland Phone +41 31 998 15 15 Fax +41 31 998 15 90 www.bernafon.com 100 50 30 90 40 70 20 80 30 60 10 70 20 0 60 50 250 500 1k 1k6 2k 2k5 Frequency/Hz 4k 8k 250 500 1k 1k6 2k 2k5 Frequency/Hz 4k 8k 10 Bernafon UK Cadzow Industrial Estate Off Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 285 968 Fax +44 1698 421 456 www.bernafon.co.uk Bernafon Australia Pty. Ltd. 12/97 Castlemaine Street Milton QLD 4064 Australia Freecall 1800 809 111 Phone +61 7 3250 0300 Fax +61 7 3250 0372 www.bernafon.com.au Bernafon New Zealand Ltd. Level 1, Building F 27-29 William Pickering Drive Albany, Auckland 0632 New Zealand Phone +64 9 920 42 40 Fax +64 9 920 42 43 www.bernafon.co.nz 05.09/BAG/951-18-110-00/subject to change Output/dB SPL 400/410/415 305/315/205 The combination of individual needs and preferences with audiometric data drives the automatic allocation of programs and the behaviour of the adaptive settings in ICOS. Remote Control Standard Remote Control dB HL Frequency responses • ICOS Tracker (Data logging) with fine-tune proposals • Sound CheckTM • 7-Channel TriQualizer™ Frequency (Hz) ICOS 205 ITE DM VC An adaptive directional full concha instrument with a size 13 battery and a rotary volume control for mild to moderately severe hearing losses. ICOS 315 ITC DM VC An adaptive directional half shell and canal instrument with a size 312 battery and rotary volume control for mild to moderately severe hearing losses. ICOS 305 ITC DM An adaptive directional canal instrument with a size 312 battery for mild to moderately severe hearing losses. ICOS 415 MC DM An adaptive directional mini-canal instrument with a size 10 battery for mild to moderate hearing losses. ICOS 410 MC A mini-canal instrument with a size 10 battery for mild to moderate hearing losses. ICOS 400 CIC A completely in the canal instrument with a size 10 battery for mild to moderate hearing losses. U U A A ICOS information ICOS information ICOS ITE 305 ITC DM 415 MC DM IEC 60118-7 IEC 60118-0 (2cc) (Ears.) (2cc) (Ears.) IEC 60118-7 (2cc) IEC 60118-0 (Ears.) OSPL 90, Peak dB SPL 112 122 112 122 110 120 OSPL 90 , 1600 Hz dB SPL 105 113 105 113 102 111 HFA OSPL 90, ANSI dB SPL 107 –– 107 –– 104 –– Output Output IEC 60118-7 2cc Coupler (IEC 60126) ICOS ITE 205 ITE DM VC 315 ITC DM VC IEC 60118-7 IEC 60118-0 IEC 60118-7 IEC 60118-0 Frequency responses 410 MC 400 CIC IEC 60118-7 (2cc) IEC 60118-0 (Ears.) (2cc) (Ears.) 104 115 104 115 106 97 105 Output/dB SPL IEC 60118-0 Earsimulator (IEC 60711) Gain / dB 120 70 110 60 OSPL 90, Peak dB SPL OSPL 90, 1600 Hz dB SPL 97 HFA OSPL 90, ANSI dB SPL 98 –– 98 –– 100 50 Output/dB SPL ICOS 415 MC DM Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 dB 46 58 43 54 41 52 Full-On Gain, Peak dB 34 45 34 45 90 40 100 50 Full-On Gain, 1600 Hz dB 40 49 38 47 34 43 Full-On Gain, 1600 Hz dB 30 39 30 39 80 30 90 40 70 20 80 30 60 10 70 20 0 60 Gain Full-On Gain, Peak Gain dB 41 –– 38 –– 34 –– HFA Full-On Gain, ANSI dB 30 –– 31 –– Reference Test Gain, IEC dB 29 38 29 38 27 35 Reference Test Gain, IEC dB 22 31 22 31 Reference Test Gain, ANSI dB 29 –– 29 –– 27 –– Reference Test Gain, ANSI dB 22 –– 21 –– Quiescent Current mA 1.2 1.2 1.1 1.1 1.1 1.1 Quiescent Current mA 1.1 1.1 0.8 0.8 Operating Current, IEC mA 1.2 1.2 1.2 1.2 1.2 1.2 Operating Current, IEC mA 1.1 1.1 0.8 0.8 Operating Current, ANSI mA 1.2 –– 1.2 –– 1.2 –– Operating Current, ANSI mA 1.1 –– 0.8 –– 500/800/1600 Hz typ., IEC General Information 1) 312 312 % <1 / <1 / <1 <2 / <2 / <1 <1 / <1 / <1 <2 / <2 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 500/800/1600 Hz typ., ANSI % Frequency Range, ANSI Hz Equiv. Input Noise, IEC/ANSI 1) dB 100–7400 –– –– 100–7500 14/14 –– –– 100–7500 14/15 –– –– 14/15 Telecoil 1 mA/m 1600 Hz, IEC dB SPL 72 81 70 79 67 75 Telecoil HFA SPLITS, ANSI dB SPL 85 –– 85 –– 84 –– optional optional optional Programmable Telecoil optional optional optional AutoTelephone optional optional optional Push button yes yes yes Volume Control yes yes Remote Control reception coil Additional Information 13 –– Technical data measured with expansion, corresponding to Soft Noise Management level 3. 1) All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. Battery type Distortion Battery type Distortion General Information 500/800/1600 Hz typ., IEC <1 / <1 / <1 <1 / <1 / <1 % Hz 110–7500 Equiv. Input Noise, IEC/ANSI 1) dB <1 / <1 / <2 <1 / <1 / <1 –– <1 / <1 / <1 –– 14/14 250 500 1k 1k6 2k 2k5 4k 8k 250 500 Frequency/Hz 1k 1k6 2k 2k5 4k 8k 10 Frequency/Hz 110–7500 <1 / <1 / <1 –– –– 19/17 Telecoil 1 mA/m 1600 Hz, IEC dB SPL –– –– –– –– Telecoil HFA SPLITS, ANSI dB SPL –– –– –– –– 50 10 optional optional Programmable Telecoil –– –– AutoTelephone –– –– Push button optional Volume Control –– optional –– Output/dB SPL Gain / dB 120 70 110 60 100 50 90 40 80 Output/dB SPL Gain / dB 130 80 120 70 110 60 100 50 30 90 40 70 20 80 30 60 10 70 20 0 60 50 Technical data measured with expansion, corresponding to Soft Noise Management level 3. 250 500 1k 1k6 2k 2k5 Frequency/Hz All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. 4k 8k ICOS 410 MC ICOS 400 CIC Output OSPL 90 Full-On Gain 250 500 1k 1k6 2k 2k5 4k 8k 10 Frequency/Hz Adapters and cables ICOS is programmed with OASIS plus, Version 6.0 or later – a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 3.0 with a Hi-Pro or a NOAHlinkTM is required. All colors are available for all instruments. Programming adapter for all ITE’s beige % 500/800/1600 Hz typ., ANSI ICOS Colors 10 Frequency Range, ANSI Remote Control reception coil Additional Information Current Current HFA Full-On Gain, ANSI pink brown dark brown FlexConnect REF. 390-01-180-05 Programming cables Programming cables Nr. 2, new standard (HiPro) Nr. 2, new standard (NOAHlink) Blue, left Red, right REF. 384-20-033-00 REF. 384-20-032-00 Blue, left Red, right REF. 384-20-035-00 REF. 384-20-034-00 Note: Always use new batteries for programming. U U A A ICOS information ICOS information ICOS ITE 305 ITC DM 415 MC DM IEC 60118-7 IEC 60118-0 (2cc) (Ears.) (2cc) (Ears.) IEC 60118-7 (2cc) IEC 60118-0 (Ears.) OSPL 90, Peak dB SPL 112 122 112 122 110 120 OSPL 90 , 1600 Hz dB SPL 105 113 105 113 102 111 HFA OSPL 90, ANSI dB SPL 107 –– 107 –– 104 –– Output Output IEC 60118-7 2cc Coupler (IEC 60126) ICOS ITE 205 ITE DM VC 315 ITC DM VC IEC 60118-7 IEC 60118-0 IEC 60118-7 IEC 60118-0 Frequency responses 410 MC 400 CIC IEC 60118-7 (2cc) IEC 60118-0 (Ears.) (2cc) (Ears.) 104 115 104 115 106 97 105 Output/dB SPL IEC 60118-0 Earsimulator (IEC 60711) Gain / dB 120 70 110 60 OSPL 90, Peak dB SPL OSPL 90, 1600 Hz dB SPL 97 HFA OSPL 90, ANSI dB SPL 98 –– 98 –– 100 50 Output/dB SPL ICOS 415 MC DM Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 dB 46 58 43 54 41 52 Full-On Gain, Peak dB 34 45 34 45 90 40 100 50 Full-On Gain, 1600 Hz dB 40 49 38 47 34 43 Full-On Gain, 1600 Hz dB 30 39 30 39 80 30 90 40 70 20 80 30 60 10 70 20 0 60 Gain Full-On Gain, Peak Gain dB 41 –– 38 –– 34 –– HFA Full-On Gain, ANSI dB 30 –– 31 –– Reference Test Gain, IEC dB 29 38 29 38 27 35 Reference Test Gain, IEC dB 22 31 22 31 Reference Test Gain, ANSI dB 29 –– 29 –– 27 –– Reference Test Gain, ANSI dB 22 –– 21 –– Quiescent Current mA 1.2 1.2 1.1 1.1 1.1 1.1 Quiescent Current mA 1.1 1.1 0.8 0.8 Operating Current, IEC mA 1.2 1.2 1.2 1.2 1.2 1.2 Operating Current, IEC mA 1.1 1.1 0.8 0.8 Operating Current, ANSI mA 1.2 –– 1.2 –– 1.2 –– Operating Current, ANSI mA 1.1 –– 0.8 –– 500/800/1600 Hz typ., IEC General Information 1) 312 312 % <1 / <1 / <1 <2 / <2 / <1 <1 / <1 / <1 <2 / <2 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 500/800/1600 Hz typ., ANSI % Frequency Range, ANSI Hz Equiv. Input Noise, IEC/ANSI 1) dB 100–7400 –– –– 100–7500 14/14 –– –– 100–7500 14/15 –– –– 14/15 Telecoil 1 mA/m 1600 Hz, IEC dB SPL 72 81 70 79 67 75 Telecoil HFA SPLITS, ANSI dB SPL 85 –– 85 –– 84 –– optional optional optional Programmable Telecoil optional optional optional AutoTelephone optional optional optional Push button yes yes yes Volume Control yes yes Remote Control reception coil Additional Information 13 –– Technical data measured with expansion, corresponding to Soft Noise Management level 3. 1) All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. Battery type Distortion Battery type Distortion General Information 500/800/1600 Hz typ., IEC <1 / <1 / <1 <1 / <1 / <1 % Hz 110–7500 Equiv. Input Noise, IEC/ANSI 1) dB <1 / <1 / <2 <1 / <1 / <1 –– <1 / <1 / <1 –– 14/14 250 500 1k 1k6 2k 2k5 4k 8k 250 500 Frequency/Hz 1k 1k6 2k 2k5 4k 8k 10 Frequency/Hz 110–7500 <1 / <1 / <1 –– –– 19/17 Telecoil 1 mA/m 1600 Hz, IEC dB SPL –– –– –– –– Telecoil HFA SPLITS, ANSI dB SPL –– –– –– –– 50 10 optional optional Programmable Telecoil –– –– AutoTelephone –– –– Push button optional Volume Control –– optional –– Output/dB SPL Gain / dB 120 70 110 60 100 50 90 40 80 Output/dB SPL Gain / dB 130 80 120 70 110 60 100 50 30 90 40 70 20 80 30 60 10 70 20 0 60 50 Technical data measured with expansion, corresponding to Soft Noise Management level 3. 250 500 1k 1k6 2k 2k5 Frequency/Hz All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. 4k 8k ICOS 410 MC ICOS 400 CIC Output OSPL 90 Full-On Gain 250 500 1k 1k6 2k 2k5 4k 8k 10 Frequency/Hz Adapters and cables ICOS is programmed with OASIS plus, Version 6.0 or later – a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 3.0 with a Hi-Pro or a NOAHlinkTM is required. All colors are available for all instruments. Programming adapter for all ITE’s beige % 500/800/1600 Hz typ., ANSI ICOS Colors 10 Frequency Range, ANSI Remote Control reception coil Additional Information Current Current HFA Full-On Gain, ANSI pink brown dark brown FlexConnect REF. 390-01-180-05 Programming cables Programming cables Nr. 2, new standard (HiPro) Nr. 2, new standard (NOAHlink) Blue, left Red, right REF. 384-20-033-00 REF. 384-20-032-00 Blue, left Red, right REF. 384-20-035-00 REF. 384-20-034-00 Note: Always use new batteries for programming. U U A A IEC 60118-7 2cc Coupler (IEC 60126) Output/dB SPL IEC 60118-0 Earsimulator (IEC 60711) Gain / dB 120 70 110 60 Output / dB SPL ICOS 205 ITE DM VC Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 50 90 40 100 50 80 30 90 40 70 20 80 30 60 10 70 20 0 60 250 500 1k 1k6 2k 2k5 4k 8k 250 500 Frequency/Hz 1k 1k6 2k 2k5 4k The Lifestyle Profile: provides a structured framework for identifying the specific communi- cation needs of your client. It is this information that drives the automatic behaviour of ICOS. ICOS 205 ITE DM VC ICOS 315 ITC DM VC ICOS 305 ITC DM ICOS 415 MC DM ICOS 410 MC / ICOS 400 CIC • Sound CheckTM: offers the tools that are necessary for verifying the initial fit of ICOS. ICOS: The first hearing system with Personalized Audio NavigationTM • Automatic Program Allocation: OASIS plus defines what user programs have to be assigned to cover the client‘s lifestyle priorities. Client Profile To benefit from the unique features in ICOS, OASIS plus introduces an enhanced workflow. 100 50 8k 10 • • Global Fine-Tuning: Master tools for optimizing the response for all programs simultaneously. Frequency/Hz • Environment Specific Controls: A dedicated set of controls offered to specifically optimize different environments and programs. Output/dB SPL Gain / dB 120 70 110 60 100 50 Output / dB SPL ICOS 315 ITC DM VC Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 100 50 90 40 80 30 90 40 70 20 80 30 60 10 70 20 50 0 60 10 250 500 1k 1k6 2k 2k5 4k 8k 250 Product information Fitting in OASIS plus 500 Frequency/Hz 1k 1k6 2k 2k5 4k 8k • ICOS Tracker: Not only can the important information about the clients use of ICOS be viewed but OASIS plus will offer fine-tuning suggestions based on the accumulated data. • Lifestyle Profile • Clinical Profile AudioMatics The adaptive features in ICOS are combined as needed to maximize performance in the recognized environment. • • • • • • • • • • All ICOS System can be operated with the optional Bernafon Remote Control RC-S. REF. 160-02-310-00 For patients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered. Custom Remote Control REF. 160-02-320-00 Frequency/Hz Audio Navigation ProgramTM 3 freely configurable listening programs Additional dedicated AutoTelephone program Multi-Dimensional Directionality Adaptive Noise Reduction in 8 bands Audio RecognitionTM with 4 different monitors Soft Noise Management Adaptive Feedback Cancellation OpenFitTM 7-channel digital signal processing Optimization Apart from advanced fine-tuning tools, ICOS offers an in-depth insight into the use and behavior of the hearing system while worn by your client. It provides a solid foundation for clear and accurate recommendations for maximal optimization. Gain / dB 120 70 110 60 100 50 90 40 80 Output / dB SPL ICOS 305 ITC DM Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 Manufacturer: 110 60 Bernafon AG Morgenstrasse 131 3018 Bern Switzerland Phone +41 31 998 15 15 Fax +41 31 998 15 90 www.bernafon.com 100 50 30 90 40 70 20 80 30 60 10 70 20 0 60 50 250 500 1k 1k6 2k 2k5 Frequency/Hz 4k 8k 250 500 1k 1k6 2k 2k5 Frequency/Hz 4k 8k 10 Bernafon UK Cadzow Industrial Estate Off Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 285 968 Fax +44 1698 421 456 www.bernafon.co.uk Bernafon Australia Pty. Ltd. 12/97 Castlemaine Street Milton QLD 4064 Australia Freecall 1800 809 111 Phone +61 7 3250 0300 Fax +61 7 3250 0372 www.bernafon.com.au Bernafon New Zealand Ltd. Level 1, Building F 27-29 William Pickering Drive Albany, Auckland 0632 New Zealand Phone +64 9 920 42 40 Fax +64 9 920 42 43 www.bernafon.co.nz 05.09/BAG/951-18-110-00/subject to change Output/dB SPL 400/410/415 305/315/205 The combination of individual needs and preferences with audiometric data drives the automatic allocation of programs and the behaviour of the adaptive settings in ICOS. Remote Control Standard Remote Control dB HL Frequency responses • ICOS Tracker (Data logging) with fine-tune proposals • Sound CheckTM • 7-Channel TriQualizer™ Frequency (Hz) ICOS 205 ITE DM VC An adaptive directional full concha instrument with a size 13 battery and a rotary volume control for mild to moderately severe hearing losses. ICOS 315 ITC DM VC An adaptive directional half shell and canal instrument with a size 312 battery and rotary volume control for mild to moderately severe hearing losses. ICOS 305 ITC DM An adaptive directional canal instrument with a size 312 battery for mild to moderately severe hearing losses. ICOS 415 MC DM An adaptive directional mini-canal instrument with a size 10 battery for mild to moderate hearing losses. ICOS 410 MC A mini-canal instrument with a size 10 battery for mild to moderate hearing losses. ICOS 400 CIC A completely in the canal instrument with a size 10 battery for mild to moderate hearing losses. U U A A ICOS information ICOS information ICOS ITE 305 ITC DM 415 MC DM IEC 60118-7 IEC 60118-0 (2cc) (Ears.) (2cc) (Ears.) IEC 60118-7 (2cc) IEC 60118-0 (Ears.) OSPL 90, Peak dB SPL 112 122 112 122 110 120 OSPL 90 , 1600 Hz dB SPL 105 113 105 113 102 111 HFA OSPL 90, ANSI dB SPL 107 –– 107 –– 104 –– Output Output IEC 60118-7 2cc Coupler (IEC 60126) ICOS ITE 205 ITE DM VC 315 ITC DM VC IEC 60118-7 IEC 60118-0 IEC 60118-7 IEC 60118-0 Frequency responses 410 MC 400 CIC IEC 60118-7 (2cc) IEC 60118-0 (Ears.) (2cc) (Ears.) 104 115 104 115 106 97 105 Output/dB SPL IEC 60118-0 Earsimulator (IEC 60711) Gain / dB 120 70 110 60 OSPL 90, Peak dB SPL OSPL 90, 1600 Hz dB SPL 97 HFA OSPL 90, ANSI dB SPL 98 –– 98 –– 100 50 Output/dB SPL ICOS 415 MC DM Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 dB 46 58 43 54 41 52 Full-On Gain, Peak dB 34 45 34 45 90 40 100 50 Full-On Gain, 1600 Hz dB 40 49 38 47 34 43 Full-On Gain, 1600 Hz dB 30 39 30 39 80 30 90 40 70 20 80 30 60 10 70 20 0 60 Gain Full-On Gain, Peak Gain dB 41 –– 38 –– 34 –– HFA Full-On Gain, ANSI dB 30 –– 31 –– Reference Test Gain, IEC dB 29 38 29 38 27 35 Reference Test Gain, IEC dB 22 31 22 31 Reference Test Gain, ANSI dB 29 –– 29 –– 27 –– Reference Test Gain, ANSI dB 22 –– 21 –– Quiescent Current mA 1.2 1.2 1.1 1.1 1.1 1.1 Quiescent Current mA 1.1 1.1 0.8 0.8 Operating Current, IEC mA 1.2 1.2 1.2 1.2 1.2 1.2 Operating Current, IEC mA 1.1 1.1 0.8 0.8 Operating Current, ANSI mA 1.2 –– 1.2 –– 1.2 –– Operating Current, ANSI mA 1.1 –– 0.8 –– 500/800/1600 Hz typ., IEC General Information 1) 312 312 % <1 / <1 / <1 <2 / <2 / <1 <1 / <1 / <1 <2 / <2 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 <1 / <1 / <1 500/800/1600 Hz typ., ANSI % Frequency Range, ANSI Hz Equiv. Input Noise, IEC/ANSI 1) dB 100–7400 –– –– 100–7500 14/14 –– –– 100–7500 14/15 –– –– 14/15 Telecoil 1 mA/m 1600 Hz, IEC dB SPL 72 81 70 79 67 75 Telecoil HFA SPLITS, ANSI dB SPL 85 –– 85 –– 84 –– optional optional optional Programmable Telecoil optional optional optional AutoTelephone optional optional optional Push button yes yes yes Volume Control yes yes Remote Control reception coil Additional Information 13 –– Technical data measured with expansion, corresponding to Soft Noise Management level 3. 1) All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. Battery type Distortion Battery type Distortion General Information 500/800/1600 Hz typ., IEC <1 / <1 / <1 <1 / <1 / <1 % Hz 110–7500 Equiv. Input Noise, IEC/ANSI 1) dB <1 / <1 / <2 <1 / <1 / <1 –– <1 / <1 / <1 –– 14/14 250 500 1k 1k6 2k 2k5 4k 8k 250 500 Frequency/Hz 1k 1k6 2k 2k5 4k 8k 10 Frequency/Hz 110–7500 <1 / <1 / <1 –– –– 19/17 Telecoil 1 mA/m 1600 Hz, IEC dB SPL –– –– –– –– Telecoil HFA SPLITS, ANSI dB SPL –– –– –– –– 50 10 optional optional Programmable Telecoil –– –– AutoTelephone –– –– Push button optional Volume Control –– optional –– Output/dB SPL Gain / dB 120 70 110 60 100 50 90 40 80 Output/dB SPL Gain / dB 130 80 120 70 110 60 100 50 30 90 40 70 20 80 30 60 10 70 20 0 60 50 Technical data measured with expansion, corresponding to Soft Noise Management level 3. 250 500 1k 1k6 2k 2k5 Frequency/Hz All measurements are made according to IEC 60118 if not otherwise mentioned. ANSI refers to ANSI S3.22-2003. The Full-On Gain setting can be programmed into the instrument from OASIS plus for verification purposes. 4k 8k ICOS 410 MC ICOS 400 CIC Output OSPL 90 Full-On Gain 250 500 1k 1k6 2k 2k5 4k 8k 10 Frequency/Hz Adapters and cables ICOS is programmed with OASIS plus, Version 6.0 or later – a NOAH compatible, MS-Windows based PC-Fitting software. NOAH 3.0 with a Hi-Pro or a NOAHlinkTM is required. All colors are available for all instruments. Programming adapter for all ITE’s beige % 500/800/1600 Hz typ., ANSI ICOS Colors 10 Frequency Range, ANSI Remote Control reception coil Additional Information Current Current HFA Full-On Gain, ANSI pink brown dark brown FlexConnect REF. 390-01-180-05 Programming cables Programming cables Nr. 2, new standard (HiPro) Nr. 2, new standard (NOAHlink) Blue, left Red, right REF. 384-20-033-00 REF. 384-20-032-00 Blue, left Red, right REF. 384-20-035-00 REF. 384-20-034-00 Note: Always use new batteries for programming. U U A A IEC 60118-7 2cc Coupler (IEC 60126) Output/dB SPL IEC 60118-0 Earsimulator (IEC 60711) Gain / dB 120 70 110 60 Output / dB SPL ICOS 205 ITE DM VC Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 50 90 40 100 50 80 30 90 40 70 20 80 30 60 10 70 20 0 60 250 500 1k 1k6 2k 2k5 4k 8k 250 500 Frequency/Hz 1k 1k6 2k 2k5 4k The Lifestyle Profile: provides a structured framework for identifying the specific communi- cation needs of your client. It is this information that drives the automatic behaviour of ICOS. ICOS 205 ITE DM VC ICOS 315 ITC DM VC ICOS 305 ITC DM ICOS 415 MC DM ICOS 410 MC / ICOS 400 CIC • Sound CheckTM: offers the tools that are necessary for verifying the initial fit of ICOS. ICOS: The first hearing system with Personalized Audio NavigationTM • Automatic Program Allocation: OASIS plus defines what user programs have to be assigned to cover the client‘s lifestyle priorities. Client Profile To benefit from the unique features in ICOS, OASIS plus introduces an enhanced workflow. 100 50 8k 10 • • Global Fine-Tuning: Master tools for optimizing the response for all programs simultaneously. Frequency/Hz • Environment Specific Controls: A dedicated set of controls offered to specifically optimize different environments and programs. Output/dB SPL Gain / dB 120 70 110 60 100 50 Output / dB SPL ICOS 315 ITC DM VC Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 110 60 100 50 90 40 80 30 90 40 70 20 80 30 60 10 70 20 50 0 60 10 250 500 1k 1k6 2k 2k5 4k 8k 250 Product information Fitting in OASIS plus 500 Frequency/Hz 1k 1k6 2k 2k5 4k 8k • ICOS Tracker: Not only can the important information about the clients use of ICOS be viewed but OASIS plus will offer fine-tuning suggestions based on the accumulated data. • Lifestyle Profile • Clinical Profile AudioMatics The adaptive features in ICOS are combined as needed to maximize performance in the recognized environment. • • • • • • • • • • All ICOS System can be operated with the optional Bernafon Remote Control RC-S. REF. 160-02-310-00 For patients that have chosen to use more than one Remote (i.e. one in the office and one at home) the Custom Remote Control should be ordered. Custom Remote Control REF. 160-02-320-00 Frequency/Hz Audio Navigation ProgramTM 3 freely configurable listening programs Additional dedicated AutoTelephone program Multi-Dimensional Directionality Adaptive Noise Reduction in 8 bands Audio RecognitionTM with 4 different monitors Soft Noise Management Adaptive Feedback Cancellation OpenFitTM 7-channel digital signal processing Optimization Apart from advanced fine-tuning tools, ICOS offers an in-depth insight into the use and behavior of the hearing system while worn by your client. It provides a solid foundation for clear and accurate recommendations for maximal optimization. Gain / dB 120 70 110 60 100 50 90 40 80 Output / dB SPL ICOS 305 ITC DM Output OSPL 90 Full-On Gain Gain / dB 130 80 120 70 Manufacturer: 110 60 Bernafon AG Morgenstrasse 131 3018 Bern Switzerland Phone +41 31 998 15 15 Fax +41 31 998 15 90 www.bernafon.com 100 50 30 90 40 70 20 80 30 60 10 70 20 0 60 50 250 500 1k 1k6 2k 2k5 Frequency/Hz 4k 8k 250 500 1k 1k6 2k 2k5 Frequency/Hz 4k 8k 10 Bernafon UK Cadzow Industrial Estate Off Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 285 968 Fax +44 1698 421 456 www.bernafon.co.uk Bernafon Australia Pty. Ltd. 12/97 Castlemaine Street Milton QLD 4064 Australia Freecall 1800 809 111 Phone +61 7 3250 0300 Fax +61 7 3250 0372 www.bernafon.com.au Bernafon New Zealand Ltd. Level 1, Building F 27-29 William Pickering Drive Albany, Auckland 0632 New Zealand Phone +64 9 920 42 40 Fax +64 9 920 42 43 www.bernafon.co.nz 05.09/BAG/951-18-110-00/subject to change Output/dB SPL 400/410/415 305/315/205 The combination of individual needs and preferences with audiometric data drives the automatic allocation of programs and the behaviour of the adaptive settings in ICOS. Remote Control Standard Remote Control dB HL Frequency responses • ICOS Tracker (Data logging) with fine-tune proposals • Sound CheckTM • 7-Channel TriQualizer™ Frequency (Hz) ICOS 205 ITE DM VC An adaptive directional full concha instrument with a size 13 battery and a rotary volume control for mild to moderately severe hearing losses. ICOS 315 ITC DM VC An adaptive directional half shell and canal instrument with a size 312 battery and rotary volume control for mild to moderately severe hearing losses. ICOS 305 ITC DM An adaptive directional canal instrument with a size 312 battery for mild to moderately severe hearing losses. ICOS 415 MC DM An adaptive directional mini-canal instrument with a size 10 battery for mild to moderate hearing losses. ICOS 410 MC A mini-canal instrument with a size 10 battery for mild to moderate hearing losses. ICOS 400 CIC A completely in the canal instrument with a size 10 battery for mild to moderate hearing losses. U