CyberPower White Paper
Transcription
CyberPower White Paper
www.CPSww.com GreenPower UPS™ Technology at a Glance - The Advanced Energy-Saving Technology for Power Backup 1 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com Executive Summary This report is to provide insights on a patented UPS energy-saving circuit design called GreenPower UPS™ Technology, introduced by CyberPower Systems, the world-leading UPS provider. The GreenPower UPS™ Technology represents multiple advanced energy-saving designs that improve the operating efficiency and eliminate waste energy consumption. As a result, consumers will enjoy significant energy cost savings with the adoption of GreenPower UPS™ Technology. Among the most common two UPS topologies, Line-Interactive and Online DoubleConversion topology, the formers are considered as more reliable and better cost-savings as fewer components employed; and from the experiment result, the GreenPower UPS™ has been proven to be superior at any load level, which derives from its advanced bypass circuit design. Commitment to the environment protection is one of the most critical corporate visions which CyberPower possess. The development of GreenPower UPS™ Technology can not only improve the power efficiency of data centres therefore less power consumption, but also lower the budget for cooling systems hence the decrease of operation cost. Legal Notice Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission is prohibited. We make every effort to provide you with accurate, complete and current information. However, we offer no guarantee on information contained in this document. The contents of this document are provided "as is". We reserve the right to make updates or changes of any information contained in this document without prior notice. Notably, products shown may be changed or suppressed at any time 2 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com What is GreenPower UPS™ Technology? 3 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com Introduction With advanced technology evolves, people are now living a better life and enjoying all IT convenience at ease. However, all comforts come at certain costs. In recent years, the soaring energy costs have significantly increased the operating expenses of corporations. Take in to consideration of the raising electricity costs, it had increased 9.3% in 2006, which is the largest one-year jump since 19811. With depleting natural resources derived from energy-consuming actions, behaviour changes are essential to be made from not only an economical view in saving costs but a more moral concern of ensuring sustainability for future generations. As the issue of energy-saving is increasingly shaping consumer behaviour in today’s highly competitive business environment, consumers nowadays are tend to weigh more on products’ “Green Performance” when making buying decision, which has given rise to the trend of “Green IT” products. In today’s IT marketplace, a significant numbers of consumers are considering more on lifetime energy efficiency over actual cost when purchasing between competing products, and this has been further evidenced by the result as below2: Over 50% of consumers consider IT vendors' "Greenness" when selecting a supplier. One-third of consumers already consider it "important" to "very important" that IT suppliers have green offerings. Almost 80% of executives say that Green IT is growing in importance for their organization. The #1 driver for Green IT adoption is economic - to reduce operational costs. Our Commitment to the Environment As a world-leading UPS manufacturer, CyberPower has not only made it dream-come-true for businesses and individuals implementing Green IT principles but adopted green practices throughout the operation, including the recently granted ENERGY STAR qualification, certification of CEC, full compliance to the Restriction on Hazardous Substances (RoHS), accordance with Waste Electrical and Electronic Equipment (WEEE) protocols as well as receiving ISO 14001 and IECQ QC080000 certificate for internal management of environmental policies and hazardous substance restrictions. 1 2 Annual Energy Outlook 2008, the Energy Information Administration, 2008. Green IT Survey, http://www.idc.com/getdoc.jsp?containerId=prUS20932407, IDC, 2008 4 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com Along with the “Green Commitment” throughout the business, CyberPower is dedicated to the development of efficient GreenPower UPS™ Energy-Saving Technology, while ensures customers an unprecedented selection of high-quality, feature-rich and reliable power protection products. GreenPower UPS™ Technology Power equipment plays an important role in the power consumption of data centres. It is reported that averagely the UPS consumes 18% of the electricity in data centres3. Hence the reduction in power consumption of UPS equipment will considerably reflect in lower electricity cost for corporate, which has lead to the rise of GreenPower UPS™ Technology. The GreenPower UPS™ Technology features with the advanced bypass circuit design which could reduce UPS energy costs by up to 75% compared to conventional models. It efficiently bypasses the transformer when utility power is normal. As utility power is normal over 88% of the time, the GreenPower UPS™ operates primarily in its cost-reducing bypass mode. As a result, users will enjoy significant energy cost savings with the adoption of GreenPower UPS™ Technology. 3 Implementing Energy Efficient Data Centers, APC, 2006. 5 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com How GreenPower UPS™ Technology Works? 6 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com UPS Topology Comparison The most common topology in use for UPS equipment is Online Double-Conversion and Line-Interactive UPS for power range from 750VA to 6KVA. Among all UPS with different topology, the Line-Interactive models are especially widely adapted thanks to its better efficiency4 with reliability. Line-Interactive Topology With Line-Interactive models, the power consumption will be lower and less heat generated when comparing to Online Double-Conversion UPS. In addition, the reliability of Line-Interactive models is superior due to simplifier structure and fewer components are required. Figure 1 Line-Interactive Topology (Based on IEC 62040-3) According to statistics5, the average power outage time is about 100 minutes per year, thus batteries are fully charged most of the life time. However, the transformer remains connected to the utility regardless of the UPS status in line-interactive design. As a result, huge energy loss would be incurred in the main transformer. The GreenPower UPS™ can intelligently cut off the power from transformer when UPS is operating during normal mode. Therefore, unnecessary power loss will be eliminated when utility power is normal, effectively reduce energy and electricity expenses; when utility power is abnormal, the UPS will switch to “Battery” or “AVR” mode and the GreenPower UPS™ operates exactly the same as traditional UPS does. 4 Efficiency=(work output/ work input) x 100 The Quality of US Commercial AC Power, Goldstein and Speranza, ATT Bell Labs, Intellect conference, 1982 5 7 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com In addition to the energy-savings from UPS, less heat is generated under line mode. This will help to decrease the load on data centre cooling systems while providing efficient electricity savings. Online Double Conversion Topology Online Double-Conversion topology provides extra layer insulation from power problems which is achieved by continuously operating off battery power and zero transfer time during power outage. Bypass switch is commonly employed. However, same as Line-Interactive models, a few milliseconds output drop is inevitable during switching between bypass and operation mode. The efficiency of Online Double-Conversion UPS is typically between 80% and 90%, depends on different circuit designs. As models with this topology usually come with sophisticated structure, more components will be required thus more power consumption will be generated which may lead to potential reliability issues. Figure 2 Double-conversion Online Topology(Based on IEC 62040-3) With the lower operating temperature and less components employed, the GreenPower UPS™ is considered as more reliable than Online Double-Conversion models since unnecessary current travel could be avoided to reduce power loss. Furthermore, from a cost-saving viewpoint, the estimated annual energy cost-saving would be USD$140 by replacing an Online Double-Conversion UPS with GreenPower UPS™. Considering the average life span of UPS product is about 5 years, the accumulated energy cost-savings will be as high as USD$700. The quality of utility power is no doubt another key issue when selecting power backup systems. In areas with frequent power blackouts, Online Double-Conversion UPS systems will be recommended to provide adequate protection for 8 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com mission-criticals; while in regions with better power quality, the GreenPower UPS™ will be a good alternative. Why the GreenPower UPS™ Technology is better? In the efficiency comparison chart below, it is clearly stated that the efficiency rate of the GreenPower UPS™ is superior when comparing to the Line-Interactive models from two other brands at any load level. Figure 3 UPS Efficiency Comparison Chart CyberPower’s patented GreenPower UPS™ with Bypass Technology reduces UPS energy costs by up to 75% compared to conventional UPS models. Even when utility power is normal, conventional UPS models constantly pass power through the main power transformer, while the advanced circuitry of a GreenPower UPS™ bypasses the transformer. Therefore, the power efficiency is significantly increased and less heat, energy, and energy costs are decreased; when abnormal power conditions occur, the GreenPower UPS™ automatically runs power through the transformer to regulate voltage and provides “safe” power. As utility power is normal 88% of the time, the GreenPower UPS™ operates primarily in its efficient bypass mode to ensure the least degree of heat and energy consumption. 9 © 2013 CyberPower Systems, Inc. All rights reserved. www.CPSww.com Conclusion As one of the major corporate commitments, CyberPower endeavours in continuing the devotion in energy-saving practices as well as the development of Green Product for the sake of environmental protection. From an economical point of view, the application of GreenPower UPS™ will lead to significant difference in estimated electricity cost-savings therefore the decrease of overall data centre operation expenses. With the greener UPS improving the power efficiency in data centres, customers will not only enjoy the saving in OPEX but lower the budget for cooling systems. Therefore, the GreenPower UPS™ technology will undoubtedly be one of your exceptional choices for Green IT product purchase! However, the UPS consumes less than one-fifth power in data centres, adequate data centre design, especially the right-sizing for all data centre equipments is still one of the most important parts for overall power consumption saving in a data centre. 10 © 2013 CyberPower Systems, Inc. All rights reserved.