Immergas SE External Flyer Brochures

Transcription

Immergas SE External Flyer Brochures
IMMERGAS SE
EXTERNAL BOILER
Wall hung traditional hydronic system boiler
for outdoor installation
MANUFACTURED BY:
•S
ealed room fan assisted model with a 36
kW heat output
• Compact dimensions
• Automatic system by-pass
• D.H.W. Storage Tank (optional)
•E
lectronic control board microprocessor
driven
• Electronic ignition and full modulation
• Diagnostic and performance display
• Intelligent External Controller CARV2 with
outside sensor (optional)
2 YEAR*
CARV2
WARRANTY
EXTERNAL SENSOR
MAIN OPTIONS
MEASUREMENTS
CARV2 - 3.021395
External Sensor - 3.014083
Anti-freeze protection (-15oC) - 3.017324.
1000 x 555 x 255 (H x W x D) mm
Empty appliance weight - 45 kg.
MAIN FLUE KITS
Vertical concentric kit 60/100 - 3.023758.
SHOWROOM
11 Fiveways Boulevard
Keysborough
VIC 3173
PHONE 1300 00 1800
FAX (+613) 9798 5133
HUNT HEATING
The smart choice.
[email protected]
www.huntheat.com.au
IMMERGAS SE EXTERNAL BOILER
Outputs & Dimensions
Model
Code
NG./LPG
Heat output kW
Efficiency at nom. heat
output
Protection index
SE 32 kW
IMG SE 32+ E NG
IMG SE 32+ E LPG
36
87.3%
IPX5D
COMBUSTION PARAMETERS
Supply Pressure
Flue temperature at nominal output
NG (G20)
LPG (G30)
kPa
1.0
2.8
C
67
68
o
TECHNICAL DATA
Heat output NG
mJ/h (kW)
128.5 (35.7)
Heat output LPG
mJ/h (kW)
128.5 (35.7)
Burner pressure maximum NG/LPG
kPa
0.70 / 2.10
Burner pressure minimum NG/LPG
kPa
0.19 / 0.55
%
87.30
Efficiency 50/30 Nom./Min.
%
93.20
Adjustable central heating temperature
o
Efficiency 80/60 Nom./Min.
C
35 - 85
bar
1
bar (psi)
3 (44)
L
10
kPa (m H2O)
30.2 (3.1)
V/Hz
230 / 50
W
180
Expansion vessel factory-set pressure
Pressure relief setting
Expansion vessel capacity
Head available with 1000 l/h flow rate
Electrical connection
Installed electric power
F R
165
F R
95
C
F
165
95
F
C
Key:
G - Gas supply (not supplied as standard)
Key:
R G- - Return
- CH
Gas supply
(not supplied as standard)
F R- - Flow
- CH
Return
- CH
Flow -fill
CH
C F- - Cold
F R
165
C - Cold fill
95
C
F
Key:
G
R
F
C
-
Height
Height
(mm)
Gas supply (not supplied as standard) (mm)
1000
Return - CH
1000
Flow - CH
Cold fill
CORD INLET
CORD INLET
C
C1/2”
1/2”
IMG.V038.02.15.HH
Height
(mm)
1000
Width
(mm)
Depth
(mm)
555
255
CONNECTIONS
CORD INLET
GAS
C
G
* Please contact Hunt Heating for terms and conditions
SYSTEM
R
F
Width
Width
(mm)
(mm)
DepthDepth
(mm)(mm)
555
255
555
CONNECTIONS
255
CONNECTIONS
GAS
SYSTEM
GAS
G
3/4”
G
3/4”
SYSTEM
F
R
3/4” R
3/4”
3/4”
F
3/4”

Similar documents

Immergas Partage Boxes

Immergas Partage Boxes DIMV2 TOP H-LT Hydraulic manifold, 2 low consumption pumps, 1 mixing valve and electronic board DIMV2 TOPH-2LT Hydraulic manifold, 3 low consumption pumps, 2 mixing valves and electronic board

More information

Catalogue 03/2016

Catalogue 03/2016 services and generate domestic hot water. Remember that to obtain a good winter efficiency with the integration of heating by solar thermal systems, is necessary: • Heating elements that work at l...

More information