Sports - Industrial LED Lighting Manufacturer
Transcription
Sports - Industrial LED Lighting Manufacturer
SPORTS LIGHTING Florence Florence, SC52fc Keene YMCA, Civic Keene, NH:Center, AFL 600-watt, 60°x135° beam @ 4100K, St. Paul’s College, Concord, NH: HBF 150-watt, 51fc ! Florence Civic Center Arena, Florence, SC: HBXL 400-watt @ 80°, 12-AFL 800-watt @ 15°x15° @ 5000K, 27fc, vertical & horizontal Eastmoor High School, Columbus, OH: HBF 150-watt @ 143 lm/w @ 5000K, 30fc Specgrade-Sports Lighting Broch_PRINT_readerSpr Lusitano Stadium, Ludlow, LA: 66-AFL 600-watt, 15°x15° beam @ 5000K, 53fc Polaris AFL Series Spec Pro Wattage Color Temp Beam Voltage Finish Glare Shield Wattage Color Temp Beam Voltage Finish Glare Shield SPL Series Spec Pro (SPL) 1010 TAYLOR STATION ROAD, SUITE C, COLUMBUS, OH 43230-6676 www.SpecGradeLEDs.com [email protected] TOLL-FREE: 888-410-5337 FAX: 614-868-5344 Ver. 11 1010 TAYLOR STATION ROAD SUITE C, COLUMBUS, OH 43230-6676 Polaris (AFL) TOLL-FREE: 888-410-5337 FAX: 614-868-5344 Spec Pro (SPL) www.SpecGradeLEDs.com KEY FACTORS THAT MATTER FOR SPORTS LIGHTING Achieving the best outcome for sports lighting requires attention to fixture selection, quantity, placement, optics and aiming. Then there are many important variables that define the quality of lighting; ILLUMINANCE LIGHT LEVELS The right amount of light required on the playing surface differs greatly depending on the type of sport in question. In general, fast action sports with a small playing object (tennis ball) or long viewing distance will require high lighting levels. A slower speed, larger playing object (football) or closer viewing distance requires lower lighting levels. BEAM SPREAD AND UNIFORMITY When designing lighting for sports facilities it is important to minimize obtrusive, spill light and dark sections of the playing area. Various strategies are used depending on the application and a lot of consideration is given to the design to ensure the playing area will have the proper overlapping beams void of ‘hot spots’. MOUNTING & LOCATION Much consideration should be given to available mounting options. The structural design of the facility may place restrictions both in positioning of luminaires and in luminaire weight, as some structures have limited weight bearing capabilities. Placement of luminaires should also permit safe and easy access for maintenance. Many sports luminaires also place restrictions upon the positioning of luminaires with respect to the playing area to minimize glare and distraction, this requires careful design. The luminaires should also be appropriate for the local climactic conditions, and should ideally be shaped and mounted to minimize the effect of wind producing a stress on the luminaire and mounting equipment. FLORENCE CIVIC CENTER – FLORENCE, SC AVERAGE FOOTCANDLES: 141.97 AVG/MIN RATIO: 1.33 ABOUT GLARE CONTROL MINIMUM: 106 MAX/MIN RATIO: 1.50 Glare relates to light that causes discomfort or reduces the ability to see because it comes from a source that is too bright compared with its background. Reducing the glare is probably the most critical issue in sports lighting. Fixture louvre’s, optics, aiming angles, along with pole height and placement, can minimize the impact of fixture glare. SPECGRADE LED SURROUNDING ENVIRONMENT SpecGRADE SportsLED are Restriction of Hazardous Substances-compliant, using no hazardous materials in their production. Longer product lifetime means that less lamps will be produced, packaged and transported. Reduced overspill of light increases system efficiency and by combining LED with good lighting design, energy consumption can be cut by up to 70% compared with traditional lighting fixtures. All these factors and more, add up to reducing the environmental impact of SpecGRADE LED Sports Lights and help build a brighter, more vibrant and sustainable environment. SpecGRADE LED was founded by a team of dynamic, creative and experienced engineers with the goal of developing cutting edge LED Lighting technology that can light the way towards more exciting, productive, and safer environments, where our customers and their communities live, work and play. We design and can assemble a sophisticated range of professional exterior, industrial and sports lighting from our facilities in Columbus, Ohio. Our team brings more than 45 years of professional experience in lighting design, production, quality management and customer service. We are continuously devoted to improving every aspect of our business and to innovate ground breaking LED luminaires. We pride ourselves on our unparalleled customer support and confidence that your supplier can deliver the necessary specialist expertise and experience. The professionalism of the SpecGRADE LED team and the quality of the products, play very important roles in creating our many successful customer experiences from around the world. LIGHT COLOR 5700K Achieving the right consistent light color is critical for sports environments. Different light colors should not be mixed, especially when the event is televised. The ideal light color is between 5000K to 5700K which creates the effect of natural daylight. COLOR RENDERING Good color rendering is also essential to differentiate between opposing competitors or teams, and many sports use color and color contrast to improve visibility of sports equipment or differentiate between the different aspects of the playing area or targett. WHY LED MAKES SENSE FOR SPORTS LIGHTING LED is creating waves in the world of lighting and none more so than with sports illumination. The potential for improving upon current technologies and sports lighting solutions are highlighted below; RELIABILITY PERFORMANCE Unlike traditional bulb-based systems that experience a high rate of failures and fadeouts, SpecGRADE LEDs contain no parts to wear out or replace so you can be sure your light source remains maintenance-free for tens of thousands of hours. The brilliant white light of SpecGRADE SportsLED brings the spectacle of the game to life with consistent and precisely delivered light that meets the stringent demands of international HDTV broadcasting and sports governing bodies. By operating on just a fraction of the energy of traditional stadium lighting systems and more controlled light, the result is better for everyone, not to mention the person who pays the electricity bill! EFFICIENCY LED sports lighting presents an opportunity to have the most efficient use of light in both new and existing venues. LED technology can provide the same light levels as conventional HID stadium lighting, while drawing just half the energy. Sports lighting engineers have the potential to reduce fixture count by one-third to one-half, while doubling the amount of light reaching the playing surface. CONTROL Creative control helps stadiums and sports venues become more multi functional and increase the potential of revenue generation. SpecGRADE Luminaires are designed to be compatible with the leading control solutions available in the market. This enables operators to use lighting as entertainment and complete flexibility to meet the different needs for any sport. Optional switching levels for brightness can create the perfect lighting for a variety of events. THE DIRECT BENEFITS FOR OWNERS, PLAYERS & FANS LOW MAINTENANCE COSTS SpecGRADE durable Led luminaires are virtually maintenance free. There is no time consuming and expensive bulb replacements, and no more readjusting for metal halide fadeout. The LED Luminaires can operate for more than 100,000 hours without maintenance. BRIGHTER, CONSISTENT LIGHT The color temperature at 5000K to 5700K creates a daylight effect with a crisper, brighter, feeling on the field of play. Daylight color balance matches perfectly with ambient light entering a stadium or arena and the specialized optics deliver perfect uniformity on the playing surface. POWER OUTAGE PROTECTION AND INSTANT ON By operating on just half the energy of traditional stadium lighting systems, SpecGRADE LED Floods places less load on the power grid, which alone can cut down on power outages. As a precaution against normal power being interrupted, SpecGRADE luminaires are capable of instantly turning on, so the lights are up and running again in seconds. No warm up or cool down time required. ENVIRONMENT DIRECT REPLACEMENT RETURN ON INVESTMENT SpecGRADE SportsLED are Restriction of Hazardous Substances-compliant, using no hazardous materials in their production. Longer product lifetime means that less lamps will be produced, packaged and transported. Reduced overspill of light increases system efficiency and by combining LED with good lighting design, energy consumption can be cut by up to 70% compared with traditional lighting fixtures. All these factors and more, add up to reducing the environmental impact of SpecGRADE LED Sports Lights that helps build a brighter, more vibrant and sustainable environment. With SpecGRADE Fixtures, installers can partially retrofit, convert over phases or make a complete refit in one go, because the Sports LED luminaires size and weight has been carefully calculated and the mounting options are designed to drop into the existing lighting infrastructure. The universal power supply operates between 95 to 305vA to work directly with the existing power circuitry. Unlike the HID fixtures they replace, as soon as the LED Luminaires are turned on, they provide full illumination at their precise color temperature, without the need for a warm-up period. Using a laser-aimer makes precision setup easier and quicker than you can imagine. The key to any successful LED installation is to give you a realistic payback time to make sure you can enjoy greater saving over the life of the luminaire. Not only is LED vastly more reliable and efficient, but the lower maintenance cost and the energy savings from switching to SpecGRADE SportsLED is so significant that they give you super fast payback with some of the longest lasting products available. That translates to reduced operating costs and positive cashflow after reaching an early ROI breakeven point. Switching to SpecGRADE LED Floods is just smart business. AFL 200 Spec Pro (SPL) CONTROL SYSTEMS Polaris (AFL) EASY DRIVER ACCESS (4 phillips head screws) Compatible with specialist lighting controls that allows users to control the light levels via dimming or preset scenes for different levels of competition and also between televised and non televised events. ACCESSORIES SpecGRADE provides a full list of accessories to enhance performance and significantly reduce installation time: • Louvre’s for glare reduction • Custom brackets & mounts • Laser aiming tool Redundancy: Our LED printed ciruit boards (PCB) are engineered in segments powered by multiple drivers so that should an application experience a driver failure the remaining PCB segments will continue to function at 100%. • Connectors SPORTS LIGHTING SERIES Polaris AFL SERIES 200w – 1000w (22,000 to 110,000 lumens) Ideal for indoor and outdoor sports requiring asymmetrical or symmetrical beam patterns with wide area coverage TELEVISION & BROADCASTING Lighting plays a key role in the experience of watching sports and none more so than with Televised matches. The unique optics technology in our LED Luminaires precisely focuses the light, creating an intensity and uniform ratio that ensures shadows on the playing surface are eliminated. This improves the appearance of moving objects and the ease with which broadcast directors can switch camera angles and viewpoints. Since the light levels are much higher, it allows the cameras to work with a smaller aperture, giving more depth and focus. The sophisticated circuitry operates at any frame rate enabling HDTV recording to operate flicker free, for reduced glare and super slow motion recording. Additionally SpecGRADE LED Sports Floods have the ability to virtually match daylight for optimal broadcasting without the need for filtering mixed light colours. This meets and exceeds the highest professional sports broadcasting standards. Spec Pro SPL SERIES 200w – 2000w (44,000 to 220,000 lumens approx.) Ideal for outdoor sports requiring circular beam patterns with long range projection Our Product Recall Insurance is designed to give you the peace of mind of knowing that, in addition to our Corporate Warranty (see our website at www.SpecGradeLED.com), every SpecGrade LED luminaire is underwritten for a period of 5 years by an A+ rated (Standard & Poors, AM Best) insurance company to perform per specification or it will be made right. Give us a call if you would like to discuss the unqiue-to-the-industry policy and the 24/7 hotline. We would be happy to provide you with a copy of the policy upon request. Light Levels FOOTBALL NCAA: < 5,000 seats NCAA: 5,000-25,000 seats NCAA: 25,000-45,000 seats NCAA: 45,000+ seats High School Class I High School Class II High School Class III High School Class IV High School Class V Light Levels Uniformity Ratios Horizontal Footcandles Vertical Footcandles (to 50-yard line main camera) Verticle Footcandles (to end zone camera) Horizontal Vertical 50 75 100 125 100 50 30 20 10 45 60 75 - 2.0:1 2.0:1 1.7:1 1.5:1 - 2.0:1 1.5:1 1.5:1 - - - - 75 100 125 - Horizontal Footcandles BASKETBALL NCAA standard collegiate NCAA Regional Broadcast NCAA National Broadcast NCAA National Championship Final High School Class I High School Class II High School Class III High School Class IV High School Class V 80 80 100 125 100 30 30 30 30 Vertical Footcandles (to center main side camera) 75 100 125 - Uniformity Ratios Verticle Footcandles (to end line camera) Horizontal Vertical 45 60 75 - 2.0:1 2.0:1 1.7:1 1.5:1 - 2.0:1 1.7:1 2.5:1 - Summary: Following these recommended best practices will ensure quality of light needed for the safety of participants and the enjoyment of spectators, as required. 6 pole option 6 pole option 4 pole option 4 pole option 6 pole option Standard Intercollegiate Play 10º 10º 10 20 30 40 50 40 G 20 10 10 20 30 40 50 40 G 20 10 Recommended pole placement: Standard Intercollegiate Play 10º 10º National and Regional Broadcast 6 or 8 pole option 10º 8 pole option 6 pole option 10º 10º 10º 10º 6 or 8 pole option 8 pole option 15º 15º 10 20 30 40 50 40 G 20 10 10 20 30 40 50 40 G 20 10 10º Recommended pole placement: National and Regional Broadcast 10º 15º 15º 8 pole option 6 or 8 pole option 6 pole option 10º 1. For new facilities or upgrades, it is recommended to consult a lighting professional for optimal luminaire placement and catwalk locations. 2. Optimal luminaire placement, mounting heights, and catwalk locations will impact playability and minimize glare and skip glare. 8 pole option 6 or 8 pole option 3. To achieve required vertical footcandles, some lights must be mounted beyond the sides of the court. 4. As a general rule, due to mounting heights, lower wattage luminaires are used, commonly 1000 watt. ©2007, 2011 National Collegiate Athletic Association L-1732-2 5. No luminaires are recommended in shaded areas directly aimed to the field of play. Light Levels HOCKEY NCAA Standard Collegiate NCAA Regional Broadcast NCAA National Broadcast High School Class I High School Class II High School Class III High School Class IV High School Class V Uniformity Ratios Horizontal Footcandles Vertical Footcandles (to center main side camera) Verticle Footcandles (to end line camera) Horizontal Vertical (to main camera) Vertical (to end line camera) 100 100 125 50 50 50 50 50 75 125 - 45 75 - 2.0:1 1.5:1 - 2.5:1 - 2.5:1 2.0:1 1.5:1 - - Horizontal Light Level in Footcandles BASEBALL All High School Footcandle levels are based on Illuminations Engineering (IES) standards. Infield NCAA Standard Collegiate 70 NCAA Regional Broadcast 100 NCAA National Broadcast 100 NCAA National Championship Final 125 High School Class I 30 High School Class II 20 High School Class III High School Class IV High School Class V - Outfield 70 70 70 100 30 20 - Horizonal Uniformity Ratios Infield 2.0:1 1.5:1 1.5:1 1.3:1 - Outfield 2.5:1 2.0:1 2.0:1 1.7:1 - Vertical Light Level in Footcandles High Home Plate Camera 70/40 70/40 90/50 - 1st Baseline Camera 70/40 70/40 90/50 - Summary: Following these recommended best practices will ensure quality of light needed for the safety of participants and the enjoyment of spectators, as required. Typical facility layout: 1. For new facilities or upgrades, it is recommended to consult a lighting professional for optimal luminare placement and catwalk locations. (8 Pole) (6 Pole) C1 C1 (8 Pole) D1 10º 2. As a general rule, due to mounting heights, lower wattage luminaires are used, commonly 1000 watt. •Glare zone; no poles are recommended beyond 35º off each foul-line. 20º ©2008, 2011 National Collegiate Athletic Association L-1747-2 30º (8 Pole) D2 Light Levels TENNIS NCAA Standard Collegiate NCAA Regional Broadcast NCAA National Broadcast NCAA National Championship High School Class I High School Class II High School Class III High School Class IV Verticle Footcandles (to end line camera) Horizontal Vertical Vertical (to main camera)(to end line camera) 75 75 100 125 - 45 60 75 - 125 75 60 50 1.7:1 1.7:1 1.7:1 1.5:1 - - (6 Pole) C2 C2 1. Typical court size is 60 ft x 120 ft. Primary playing area is 48 ft x 98 ft. Special consideration may be needed for lighting spectator areas depending on broadcast requirements. 2. Grey shaded areas indicate recommended pole locations. Location and quntity of poles and lighting sources shall depend on stadium design, size and pole setback requirements. 20º 4 or 8 pole option 5º 4 or 8 pole option 20º B2 A2 30° Critical Glare Zone Critical Glare Zone 3. Angle should be a minimum of 25 degrees for sharp cutoff-type luminaires and a minimum of 30 degrees for floodlights. 4. For new facilities or upgrades, it is recommended to consult a lighting professional for optimal pole placement. 10º 8 pole option Recommended pole placement: (8 Pole) A1 All High School Footcandle levels are based on Illuminations Engineering (IES) standards. 8 pole option ©2008, 2011 National Collegiate Athletic Association L-1824-2 B1 Uniformity Ratios Horizontal Vertical Footcandles Footcandles (to center main side camera) 75 100 125 - 1. Shaded areas indicate recommended pole location. 2. Line drawn through each “A” pole location must be behind home plate to ensure lighting the portion of the ball the batter sees as it crosses home plate. 3. Consideration should be given to locating “B” poles between 1/3 and 2/3 distance of the foul-line. This positioning towards the outfield pole allows the ball to be lit in a more constant perpendicular illuminance as it travels from the infield to the outfield. 4. Recommend field size is 330 ft / 375 ft / 400 ft / 375 ft 330 ft. 4 or 8 pole option 8 pole option 3rd Baseline Camera 70/40 70/40 90/50 - 4 or 8 pole option 8 pole option 5. For new facilities or upgrades, it is recommended to consult a lighting professional for optimal pole placement. ©2007, 2011 National Collegiate Athletic Association L-1703-2 LED SPORTS LIGHTING Spec Pro (SPL) AFL 200W AFL 800W, 1000W 4 58 Front View Side View Front View SPL 200W, 400W, 600W 4 58 Spec Pro (SPL) Bullseye Glare Shield (BGS) Side View 6 34 AFL 400 Visor Glare Shield (VGS) 17 Polaris 21 (AFL) 14 12 9 9 Front View 14 14 21 Side View Side View Slant Glare Shield (customized dimensions) (SGS) Remote Philips Drivers BEAM SPREAD AFL 600W 15º x 15º SPL 800W, 1000W 4 58 30º x 30º 60º x60º 85º x45º 60º x 135º 60º x 185º 21 25 17 11 19 12 25 Front View Side View 11 24 Side View EPA Rating Calculation Spec Pro (SPL) Spec Pro (SPL) EPA Rating: Spec Pro 200W, 400W & 600W with 'Bullseye' Glare Shield Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 2.4 2.2 45° from Horizontal 1.6 2.2 0° from Horizontal 2.1 2.2 Spec Pro (SPL)) EPA Rating: Spec Pro 200W, 400W & 600W with 'Visor' Glare Shield Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 2.4 2.6 45° from Horizontal 1.6 2.6 0° from Horizontal 2.5 2.6 Spec Pro (SPL) EPA Rating: Spec Pro 200W, 400W 100W with 'Bullseye' Glare Shield Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 3.4 2.9 45° from Horizontal 2.2 2.9 0° from Horizontal 2.8 2.9 Spec Pro (SPL) EPA Rating: Spec Pro 800W & 100W with 'Visor' Glare Shield Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 3.4 2.2 45° from Horizontal 1.6 2.2 0° from Horizontal 2.1 2.2 Polaris (AFL) EPA Rating: Polaris 400W* Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 3.8 0.9 45° from Horizontal 2.5 0.9 0° from Horizontal 0.8 0.9 *Recalculate for customizable glare shield Polaris (AFL) EPA Rating: Polaris 600W* Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 5.3 1.2 45° from Horizontal 3.5 1.2 0° from Horizontal 1.1 1.2 *Recalculate for customizable glare shield Polaris (AFL) EPA Rating: Polaris 800W, 1000W* Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 6.3 1.7 45° from Horizontal 4.1 1.7 0° from Horizontal 1.5 1.7 *Recalculate for customizable glare shield Polaris (AFL) Polaris (AFL) EPA Rating: Polaris 200W* Wind Direction (Sq. ft.) Fixture angle Front Side 90° from Horizontal 2.1 0.8 45° from Horizontal 1.4 0.8 0° from Horizontal 0.7 0.8 *Recalculate for customizable glare shield RECALL PRODUCT INSURANCE IP 65 DRIVER 5YEAR WARRANTY LED 10YEAR WARRANTY LM79 LM 80 RGBW DIMMABLE 0-10V REVIT (BIM) Files available DUE TO CONTINUOUS IMPROVEMENT AND INNOVATION, PRODUCT APPEARANCE AND SPECIFICATIONS MAY CHANGE WITHOUT NOTICE. ACTUAL PERFORMANCE MAY DIFFER AS A RESULT OF END-USER ENVIROMENT AND APPLICATION. Spec Pro Series (SPL) & Polaris Series (AFL) Replaces (Metal Halide) Input Voltage (V) LED Power (W) System Power (W) Spec Pro (SPL) 4000K Spec Pro (SPL) 5000K Polaris (AFL) 4000K (lm) Polaris (AFL) 5000K (lms) LED Chips LED Chip Distributions Color Temperature (Kelvin) CRI Expected Life Span (hrs) Operating Temp (F) IP Rating SPL Weight (lb) without drivers (2 Drivers =12lbs/Box) AFL Weight (lb) with drivers Spec Pro (SPL) DLC Polaris (AFL) DLC Surge Proteciton Device: UL listed 10kA 0-10V Dimming (optional) Warranty RGBW (optional) 200-Watt 500W± 400-Watt 1000W± 600-Watt 800-Watt 1000-Watt 1500-Watt 2000-Watt 1500W± 2000W± 2500W± 3700W± 5000W± 90-305 VAC, 347-480 VAC 200W 400W 600W 800W 1000W 1500W 2000W 220W 440W 660W 880W 1100W 1650W 2200W N/A 91903 60515 80011 100315 145000 (approx) 199500 (approx) N/A 44190 63700 83230m 105822 160000 (approx) 210000 (approx) 20914 41903 60515 80651 100815 N/A N/A 22105 44190 63700 84898 106122 N/A N/A LumiLEDs Luxeon-T 15° x 15°, 30° x 30°, 40° x 40°, 60° x 60°, 85° x 45°, 85° x 90°, 60° x 135°, 60° x 185° 3500K, 4000K, 5000K 74, 80 > 100,000 hrs. -40°F ~149°F IP66 Light Engines, Luminaire IP65 44 44 44 53 53 113 113 18 42 60 88 88 N/A N/A Yes Yes Yes Yes Yes No No Yes Yes Yes Yes Yes N/A N/A Yes Yes Yes Yes Yes Yes Yes Yes 10-Year LED Board, 5-Year Driver; Complete Warranty Terms at: www.SpecGradeLED.com Yes Yes No No No No No