BGR Series - Middle Atlantic
Transcription
BGR Series - Middle Atlantic
BGR Series features: 19” gangable enclosures next generation rack, designed with significant installation and performance benefits • Provides more rackspace in a smaller overall height than similar racks • Accepts patent-pending Lever Lock™ tool free and hardware free internal device and cable management system accessories • Fully welded construction provides the following weight capacities: UL Listed load capacity: 3,000 lbs., Seismic certified capacity: 1,175 lbs. • Pre-threaded ganging holes allow for rack joining after loading • Rackrail depth indicators • 1/2”, 3/4”, 1” & 1-1/2” electrical knockouts and 5/8” and 1/2” D UHF/VHF antennae knockouts on rear top & bottom, easily removable for cable pass-through. Top cable management plate (38 space and up) includes 1/2”, 3/4”, 1” 1-1/2” & 3” electrical knockouts and 5/8” and 1/2” D UHF/VHF antennae knockouts BGR shown with curved door and side panels • 23” OD width, multiple depths • Two pairs of 11-gauge, 10-32 threaded rackrail with numbered rackspace increments • Optional stackable 3” extender bay available for front and rear • Optional curved and beveled front doors in solid, vented and plexiglass styles • Attractive interior bevels • Configurable open top with vertical cable management entry points • Durable black textured powder coat finish • Seismic certified (when used with BGR-Z4 or BGR-ISO-Z4 option) with an Ip value of 1.5 • UL Listed in the US and Canada BGR shown with beveled door and side panels EIA/TIA Compliant SEISMIC CERTIFIED what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 96-01149 / rev d / 7-21-15 BGR Series specifications: 19” gangable enclosures EIA compliant 19” gangable equipment rack shall be Middle Atlantic Products model #BGR-____(see chart for available models). Overall dimensions of BGR shall be __”H x 23”W x __”D (refer to chart). Useable height of BGR shall be __ rackspaces, useable depth shall be__” (refer to chart). BGR shall come equipped with two pairs of fully adjustable steel rackrail with tapped 10-32 mounting holes in universal EIA spacing, black e-coat finish and numbered rackspaces. BGR shall have .100” thick steel along rackrail brackets, .310” thick steel at corners. BGR shall include vented locking and latching rear door, which shall be capable of accepting up to six 4-1/2” fans. Top and bottom of BGR shall feature vertical slotted vent pattern for ventilation. BGR shall have two 1” x 7”rear obround knockouts with 1/2”, 1”, 1-1/4” and 1-1/2” electrical knockouts and 5/8” and 1/2” D UHF/ VHF antennae knockouts in base and top. BGR shall have a configurable open top with vertical cable management entry points. BGR shall accept patent-pending LeverLock™ tool free and hardware free internal cable and device management system accessories. BGR shall have pre-threaded 5/16”-18 ganging holes. BGR shall be capable of ganging while fully loaded, using bolts only. BGR shall have marked rackrail depth indicators. BGR shall be of fully welded construction. BGR shall be finished in an environmentally friendly, durable black powdercoat. Grounding and bonding studs shall be 1/4-20 threaded, installed in top and base of enclosure (19 and 25 space have stud in bottom only). Fully welded construction shall provide a static capacity of 12,000 lbs. and a UL Listed load capacity of 3,000 lbs. BGR Series enclosures shall satisfy the 1997 UBC; 2001, 2007 & 2010 CBC; 2000, 2003, 2006 & 2009 IBC; ASCE 7-02, ASCE 7-05, ASCE 7-10 and the 2003, 2006 & 2009 editions of NFPA 5000 for use in areas of high seismicity, Seismic Use Group III, Zone 4 or Seismic Design Category (SDC) “D” with lateral force requirements for protecting 1,175 lbs. of essential equipment in locations with the highest level of seismicity and top floor or rooftop installations with an Importance factor (Ip) of 1.5 when used with BGR-Z4 or BGR-ISO-Z4 (isolated) seismic floor anchor bracket. BGR shall be OSHPD approved for fixed equipment anchorage in California healthcare facilities. BGR shall be UL Listed in the US and Canada. BGR shall be GREENGUARD Indoor Air Quality Certified and GREENGUARD Gold Certified. BGR enclosure shall comply with the requirements of RoHS EU Directive 2002 / 95 / EC. BGR shall be manufactured by an ISO 9001 and ISO 14001 registered company. BGR enclosure shall be warrantied to be free from defects in material or workmanship under normal use and conditions for the lifetime of the rack. Customizable specification clips available at middleatlantic.com Part # Rackspaces “A” Overall Height “B” Racking Height “C” Depth “D” Useable Depth BGR-1927 19 37.375 [949] 33.375 [848] 27 [686] 24.4 [620] BGR-2527 25 47.875 [1216] 43.875 [1114] 27 [686] 24.4 [620] BGR-3827 38 70.625 [1794] 66.625 [1692] 27 [686] 24.4 [620] BGR-4127 41 75.875 [1927] 71.875 [1826] 27 [686] 24.4 [620] BGR-4527 45 82.875 [2105] 78.875 [2003] 27 [686] 24.4 [620] 29.4 [747] options: •Lever Lock™ tool free and hardware free internal device and cable management system accessories shall be model # LL-XXYY (XX = type, YY = size, refer to middleatlantic.com for additional details) •Curved front doors shall be model # VFD-XXA (vented, 64% open area), PFD-XXA (plexi), (XX= # of rackspaces) •Beveled front doors shall be model # BFD-XX (solid), BVFD-XX (vented, 64% open area), BPFD-XX (plexi), (XX= # of rackspaces) •Front or Rear Extender, adds 3” of usable depth, model # BGR-__-EXT3 (41,45) •Cable entry rear door, shall be model # BGR-RDC__ (19, 25, 38, 41, 45) •Inner platform base shall be BS-BGR •Caster kit shall add 1” to overall height, include four casters with a 1,100 lb. weight capacity, and shall be model # CBS-BGR •Rear rail kit shall be model # BGR-RRXX (XX=# of rackspaces) •Removable keylocked side panels shall be model # BSPN-XX-YY (XX=rackspaces, YY=depth) •Seismic Zone 4, Seismic Use Group III and Seismic Design Category “D” compliancy kit shall be model # BGR-Z4 •Seismic Zone 4, Seismic Use Group III and Seismic Design Category “D” compliancy and isolation kit shall be model # BGR-ISO-Z4 •Seismic Zone 4, Seismic Use Group III and Seismic Design Category “D” riser bases shall be SRB-(1,2,3)-BGR-(32, 38)24 BGR-2532 25 47.875 [1216] 43.875 [1114] 32 [812] BGR-3832 38 70.625 [1794] 66.625 [1692] 32 [812] 29.4 [747] •Isolation kit shall be model # BGR-ISO BGR-4132 41 75.875 [1927] 71.875 [1826] 32 [812] 29.4 [747] BGR-4532 45 82.875 [2105] 78.875 [2003] 32 [812] 29.4 [747] •Front decorative trim shall be BGR-TRIM__(45,41,38, 25, 19) and shall include the following colors: Green (pre-installed), Red, Black, Blue & White BGR-4138 41 75.875 [1927] 71.875 [1826] 38 [965] 35.4 [899] BGR-4538 45 82.875 [2105] 78.875 [2003] 38 [965] 35.4 [899] what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 2 BGR Series basic dimensions all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters] top view top view 38sp & over 25sp & under 4X 3" [76] X 1-1/2" [38] X 1" [25] EKO trade size 4 x ø 1/2" [13] 'D' LKO for UHF/VHF antenna 2 x ø 5/8" [16] LKO for UHF/VHF antenna 4.61 [117] fixed hole for optional wood top 23.0 [584] 13.0 [330] 2X ø 5/8" [16] LKO for UHF/VHF antenna 4X ø 1/2" [13] 'D' LKO for UHF/VHF antenna 2x 4-1/2" fan knockouts 21.0 [533] x 21.13 [537] rect LKO 4 x ø .688 [17.48] LKO 23.0 [584] 1/4-20 x 1" grounding stud 1.91 [48] C 2X 1.10 [27.9] 5X 3.75 [95] keyhole LKO for optional wood top 2.00 [51] 21.13 [537] 5.22 [133] 2.03 [52] bottom view C 5X 3/4" [19] X 1/2" [13] EKO trade size 2.22 [56] 1.86 [47] 1.30 [33] 19.90 [505] (bottom opening) BGR-XX27= 21.91 [556] BGR-XX32= 26.91 [683] BGR-XX38= 32.91 [836] bottom opening BGR-XX27= 23.16 [588] BGR-XX32= 28.16 [715] BGR-XX38= 34.16 [867] floor mounting holes 4x ø .69 [17] (floor mounting holes) 1/4-20X1" grounding stud 21.00 [533] 19.15 [486] floor mounting 1.00 [25] front view side view 1.31 [33] A D max rear rail set back (useable depth) rear view removable ø1.33 [34] x 7.5 [190] LKO 5/8" [16] LKO for UHF/VHF antenna 2X 1" [25] X 1-1/4" [32] EKO trade size 3x ø 1/2" [13] 'D' LKO for UHF/VHF antenna 1.32 7.56 2X 1/2" [13] EKO trade size vents in rear door also accept 4-1/2" fans B 2.00 [508] A Lever Lock™ compatible, horizontal A Lever Lock™ compatible, vertical C 23.0 [584] Note: BSPN-XX-XX adds 0.656 [17] per side to width (removable side panels) what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 3 BGR Series curved & beveled doors basic dimensions all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters] curved doors (17.46 [443.6]) inside dim. between door frame open direction pivot point 2.75 [69.9] 22.0 [559] insert material: plexi or perf. 110º A .87 [22.1] ref. popout latching and locking handle 2.6 [66] ref. 1.58 [40.1] clearance from front of rail to curved door frame surface Vented Door Plexi Door Rackspaces A Height VFD-19A PFD-19A 19 35.97 [913] VFD-25A PFD-25A 25 46.47 [1180] VFD-38A PFD-38A 38 69.22 [1758] VFD-41A PFD-41A 41 74.47 [1891] VFD-45A PFD-45A 45 81.47 [2069] beveled doors BPFD-45 BVFD-45 BFD-45 clearance from front of rail to inside of door BFD-XX 2.79 [71] BVFD-XX 2.74 [70] BPFD-XX 2.60 [66] 110º A Solid Door popout latching and locking handle Vented Door Plexi Door Rackspaces A Height BFD-19 BVFD-19 BPFD-19 19 36.22 [920] BFD-25 BVFD-25 BPFD-25 25 46.72 [1187] BFD-38 BVFD-38 BPFD-38 38 69.47 [1765] BFD-41 BVFD-41 BPFD-41 41 74.72 [1898] BFD-45 BVFD-45 BPFD-45 45 81.72 [2076] 21.85 [555] what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 4 BGR Series front/rear extender & cable chase basic dimensions all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters] front/rear extender top view 3x ø 1/2" [13] 'd' lko for UHF/VHF antenna 3.0 [76] front view 1.99 [51] 23.0 [584] 1.32 [34] side view 5/8" [16] lko for UHF/VHF antenna 2x 1" [25] x 1-1/4" [32] eko trade size 7.56 [192] rear view ø1.33 [34] x 7.50 [190] lko 2x 1/2" [13] eko trade size 3.0 [76] BGR-45-EXT3 = 82.86 [2105] BGR-41-EXT3 = 75.86 [1927] Part # Used On BGR-45-EXT3 BGR-45XX, BGR-45SA-XX BGR-41-EXT3 BGR-41XX, BGR-41SA-XX 23.0 [584] 1.99 [51] attaches top CC with 5/16-18x1 ganging hardware LKO (front and back) for lock (lock included) cable chase top view .06 [1.5] gap between top and front and back CC BGR-CC-38LT = 38.0 [965] BGR-CC-32LT = 32.0 [813] BGR-CC-27LT = 27.0 [686] 2.7 [68] 4.5 [114] (top CC width) ø1.3 [33] x 7.5 [191] IKO 2x 3" [76] x 2" [51] EKO trade size (BGR-CC-27LT) 4x 3" [76] x 2" [51] EKO trade size (BGR-CC-32LT) 6x 3" [76] x 2" [51] EKO trade size (BGR-CC-38LT) front view 4.4 [112] (front and back CC width) side view 1.9 [49] BGR-CC-45FB = 82.7 [2100] BGR-CC-41FB = 75.7 [1922] BGR-CC-38FB = 70.4 [1788] BGR-CC-38LT= 35.0 [889] BGR-CC-32LT= 29.0 [737] BGR-CC-27LT= 24.0 [610] BGR-CC-45FB = 41.3 [1049] BGR-CC-41FB = 37.9 [963] .09 [2.3] vert gap between top and bot CC BGR-CC-45FB = 41.3 [1049] BGR-CC-41FB = 37.9 [963] attaches front and back CC w/ 5/16-18x5 ganging hardware Part # Used On BGR-CC-45FB BGR-45XX, BGR-45SA-XX BGR-CC-41FB BGR-41XX, BGR-41SA-XX BGR-CC-38FB BGR-38XX, BGR-38SA-XX BGR-CC-38LT BGR-XX38 BGR-CC-32LT BGR-XX32, BGR-XXSA-32 BGR-CC-27LT BGR-XX27, BGR-XXSA-27 what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 5 BGR Series fan top & top panel/rail basic dimensions all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters] BGR-552FT-FC shown BGR-276FT shown BGR-552FT-FC shown 1.53 [39] 1.05 [27] 1.53 [39] 1.05 [27] BGR-276FT shown 15.72 [399] 15.72 [399] 6.97 [177] 6.97 [177] .23 [6] .23 [6] 15.72 [399] 15.72 [399] 22.38 [568] 22.38 [568] Fan Control Part # (I) BGR-276FT Note: 1.Turn on temperature for fan controlled models can be set at 75°F (24°C), 80°F (27°C), 85°F (29°C), or 90°F (32°C). Alarm can be set at 95°F (35°C) or 100°F (38°C). (I) BGR-276FT-FC 2.“I” prefix indicates international fan top models. International models come with a universal voltage plug-in power supply and adapters. (I) BGR-552FT-FC X (I) BGR-552FT X Fan Airflow CFM Noise @ Full Quantity [M3/MIN] Speed Current Draw 4 276 [7.8] 35dBa 620 mA @ 12VDC 4 276 [7.8] 35dBa 620 mA @ 12VDC 8 552 [15.6] 38dBa 1.24A @ 12 VDC 8 552 [15.6] 38dBa 1.24A @ 12 VDC Top Panel/Rail Top Panel/Rail BGR-LVT9 22.38 [568] BGR-LVT9 22.38 [568] 2.23 [57] BGR-STP4 A B A 19.0 [483] 14.22 [361] 14.22 [361] tapped 10-32 tapped 10-32 2.23 [57] BGR-STP4 B 19.0 [483] .519 [13] .519 [13] A B A B ø7.13 [181] ø7.13 [181] 7.86 [200] .06 [2] 7.86 [200] Part # A B Type Material Open Area BGR-STP3 5.22 [133] 2.25 [57] solid aluminum - BGR-STP4 6.97 [177] 4.00 [102] solid aluminum - BGR-STP9 15.72 [399] 12.75 [324] solid steel - BGR-LVT9 15.72 [399] 12.75 [324] vented steel 64% BGR-DT9 15.72 [399] 12.75 [324] duct top steel - .06 [2] 11.19 [284] 11.19 [284] BGR-DT9, for use with DUCT-COOL-1PT and DUCT-COOL-2PT BGR-DT9, for use with DUCT-COOL-1PT and DUCT-COOL-2PT Part # A B Rackspaces BGR-TRR4 6.97 [177] 4.00 [102] 4 BGR-TRR9 15.72 [399] 12.75 [324] 9 what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 6 BGR Series caster base / inner platform base basic dimensions all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters] BS-BGR CBS-BGR 22.68 [576] 22.62 [575] 4.89 [124] 6.33 [161] 9.0 [229] 10.47 [266] 19.74 [501] 19.74 [501] 2.84 [72] 2.0 [51] 19.90 [505] BGR-XX27 11.96 [304] BGR-XX32 16.96 [431] BGR-XX38 22.96 [583] 19.90 [505] BGR-XX27 3.75 [95] BGR-XX32 8.75 [222] BGR-XX38 14.75 [375] installing casterbase to rack will increase overall height by 1.12 [28] what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 7 BGR Series cable entry rear door basic dimensions all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters] vents in rear door also accept 4-1/2"fans ø 20 [5] hole for document holder (part# DOC-SACK) A A rear door brush cable entry panel, mounts top or bottom .72 [18] 19.56 [497] 19.84 [504] 2.50 [64] height x 15.00 [381] width brush opening Part # “A” Height Used On BGR-RDC19 BGR-19XX, BGR-19SA-XX 29.59 [752] BGR-RDC25 BGR-25XX, BGR-25SA-XX 40.09 [1018] BGR-RDC38 BGR-38XX, BGR-38SA-XX 62.84 [1596] BGR-RDC41 BGR-41XX, BGR-41SA-XX 68.09 [1730] BGR-RDC45 BGR-45XX, BGR-45SA-XX 75.09 [1907] what great systems are built on. ™ middleatlantic.com | middleatlantic.ca 8