hy-spec catalogue - Wajax Central
Transcription
hy-spec catalogue - Wajax Central
HY-SPEC CATALOGUE - AC/DC POWER PACKS sit w Vi w Catalogue w. ou Hy r -S we pe b c.c si om te AC/DC Power Packs HY-SPEC PRODUCT FAMILY HY-SPEC CATALOGUE - AC/DC POWER PACKS HY-SPEC CATALOGUE - GAS ENGINE PRODUCTS Accessories AC/DC Power Packs Gas Engine Products Catalogue Catalogue WIC-EN-CATALOGUES-COVERS-2012-DYNAMIC-13-1 17 2012-06-04 15:00:51 Gear Pumps & Motors Hydraulic Cylinders WIC-EN-CATALOGUES-COVERS-2012-DYNAMIC-13-1 9 2012-06-04 14:59:23 Accessories AC/DC Power Packs Gas Engine Products Gear Pumps & Motors Hydraulic Cylinders Hydraulic Valves Mobile Directional Control Valves it w Vis w w w Vis it w.Hou y- r w Sp e ec bsi .co te m Catalogue w.Hou y- r w Sp e ec bsi .co te m w 2012-06-04 14:59:02 HY-SPEC CATALOGUE - HYDRAULIC CYLINDERS WIC-EN-CATALOGUES-COVERS-2012-DYNAMIC-13-1 21 Vis w it w.Hou y- r w Sp e ec bsi .co te m Vis w it WIC-EN-CATALOGUES-COVERS-2012-DYNAMIC-13-1 5 HY-SPEC CATALOGUE - GEAR PUMPS & MOTORS Catalogue Catalogue w w Vis w it w.Hou y- r w Sp e ec bsi .co te m HY-SPEC CATALOGUE - ACCESSORIES w.Hou y- r w Sp e ec bsi .co te m HY-SPEC CARRIES A COMPREHENSIVE SELECTION OF HIGH QUALITY HYDRAULIC PRODUCTS 2012-06-04 15:01:18 WIC-EN-CATALOGUES-COVERS-2012-DYNAMIC-13-1 13 2012-06-04 14:59:59 HY-SPEC CATALOGUE - MOBILE DIRECTIONAL CONTROL VALVES w w Vis it Catalogue w.Hou y- r w Sp e ec bsi .co te m Mobile Directional Control Valves WIC-EN-CATALOGUES-COVERS-2012-DYNAMIC-13-1 25 2012-06-04 15:01:43 For more information or OEM requests 1.866.546.3267 To find a Hy-Spec retailer near you www.Hy-Spec.com 2 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. A-Type Manifold Function AC Motor and Pump Performance Curves 12 10 Code Builder 6 D03 Directional Control Valves D03 Modular Valve Options DC Motor and Pump Performance Curves DC Motor and Pump Performance Curves - How To Read It Dimensions Dock Leveler Power Pack 17 13 9 8 14 4 Electrical Motors 14 How To Read DC Motor and Pump Performance Curves 8 Manual Override Valve Modular Valves - D03 5 13 NEMA - Bell Housings 17 Options 4 Parts Power Pack Types Prebuilt Models 16 11 4 Reservoirs 15 Schematics Snow Plow Power Pack Specifications 11 5 4 Trailer Power Pack 5 Valves Types 11 Warranty Policy Wireless Remote Control Wiring Diagrams For DC Power Pack 19 5 18 C D E H M N O P R S T V W ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m Table of Contents A 3 Prebuilt Model / Specifications & Options Power Pack Prebuilt Model MODEL MOTOR RESERVOIR VALVE CONTROL OPTION PUMP SIZE (CC/REV) OPTION HYSSE12H3GM23AAN 12volts 1.5kw Horizontal rectangular 3gal Manual power up gravity down 2.3 - HYSSE12H3GS23AAN 12volts 1.5kw Horizontal rectangular 3gal Electrical power up gravity down 2.3 - HYSSE12H3GS23AAN-R2 12volts 1.5kw Horizontal rectangular 3gal Electrical power up gravity down 2.3 2 Button remote pendant HYSSE12H40M23AAN 12volts 1.5kw Horizontal Ø7" round 4L Manual power up gravity down 2.3 - HYSSE12H5GM23AAN 12volts 1.5kw Horizontal rectangular 5gal Manual power up gravity down 2.3 - HYSSE12H5GS23AAN 12volts 1.5kw Horizontal rectangular 5gal Electrical power up gravity down 2.3 - HYSSE12H5GS23AAN-R2 12volts 1.5kw Horizontal rectangular 5gal Electrical power up gravity down 2.3 2 Button remote pendant HYSDLMFG03H50P30FHBN 1HP 1800rpm 110/220V 1PHASE 60hz Horizontal Ø7" round 5Liter Valving for dock leveler 3.0 Adjustable pressure and flow HYSHLMFG08H5GN1540BAN 2HP 3600rpm 110/220V 1PHASE 60hz Horizontal rectangular 5gal No valve 1.5 & 4.0 (Hi-low) Adjustable dump valve HY-SPEC power packs are designed for a wide range of applications. Multiples options are available to suit your needs: Specifications: • Pressure up to 210 BAR • Flow up to 10 LPM Options: General Option • Pump from 1.0 to 3.0 cc/rev. • 1.6 liter to 19 liter Horizontal and Vertical Reservoir • Pre-wired Remote control with 10’ cable AC and DC electrical option • 1.5 KW/12V/210A, 2.0KW/24V/110A DC Motor • 1 HP, 2 HP, 3 HP, 110V, 220V, 600V AC Motor • 12Volt, 24Volt, 110 Volt and 220 Volt Directional Valves Valve Option • Manual power up, gravity down • Electrical power up, gravity down • D03 directional valve • D03 Manifold for parallel and series circuit • D03 Modular valve including port relief valve, pilot operated check valve, throttle valve and pressure reducing valve • Single and double acting manual valve with multiple choice of spool 4 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. Power Pack for Trailer Application MODEL DESCRIPTION HYSSE12H3GSMOR23-R2 Dump Trailer power pack - 7 ton HYSSE12H5GSMOR23-R2 Dump Trailer power pack - 12 ton HYSLSV2-08-2NCP-M-ID 2 Position - 2 Way cartridge valve with manual override 7 3/4" Emergency manual override feature 8 1/8" MODEL DESCRIPTION HYSLSV2-08-2NCP-M-ID Manual override valve 7 ton = 22" 12 ton = 31" POWER PACK FOR SNOWPLOW MODEL DESCRIPTION HYS YBZ-F2.1S1W14/WUAAT1 Snow plow power pack Snow Plow & Trailer Power Pack Trailer Power Pack WIRELESS REMOTE CONTROL MODEL DESCRIPTION OPERATING VOLTAGE MAXIMUM CURRENT OPERATING TEMPERATURE HYS GS-HYD-D7 Wireless remote control +9 V DC to +28V DC 10 Amps DC Max -40 C to +125 C Features and Benefits • • • • • • • • • ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. Can handle 12 or 24 volt dc. Potted for protection! Installation wires instead of terminals Learning transmitter! 3-minute automatic time-out feature In-line fuse already installed! Back-up manual switches on receiver On/off switch on transm. & receiver! Can still use the tethered remote 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 5 AC / DC Power Pack Code Builder Model Shown: HYSSE12H40A123AAN3C6012 # 3 - A1 D03 MANIFOLD # 5 - 3C6012 D03 DIRECTIONAL VALVE # 2 - H40 RESERVOIR # 4 - 23 PUMP # 1 - SE12 DC MOTOR Model Shown Specification • • • • 1.5 KW/12V/210A DC Motor. 4 liter, 7” Diameter Horizontal Reservoir 2.3 cc/rev Pump D03, 3 Pos./4 Ways, Tandem Center, 12V, Din connection, Directional Valve. See page 9 for performances curves MODEL CODE EXEMPLE 6 #0 #1 #2 #3 #4 AAN #5 #6 #7 HYS SE12 H40 A1 23 AAN 3C6012 - - 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. DESCRIPTION CODE DESCRIPTION # 1 MOTOR # 3 CONTROL VALVE (Cont’d) SE12 12 VOLT, SE TYPE A3P MANIFOLD FOR 3 D03 VALVES, PARALLEL CIRCUIT SE24 24 VOLT, SE TYPE A3S MANIFOLD FOR 3 D03 VALVES, SERIES CIRCUIT MFD01 1HP/220/440/3PH/1800 RPM A4P MANIFOLD FOR 4 D03 VALVES, PARALLEL CIRCUIT MFD02 1HP/220/440/3PH/3600 RPM A4S MANIFOLD FOR 4 D03 VALVES, SERIES CIRCUIT MFG03 1HP/110/220/1PH/1800 RPM MFG04 1HP/110/220/1PH/3600 RPM 10 1.0 CC/REV MFD05 2HP/220/440/3PH/1800 RPM 15 1.5 CC/REV MFA05 2HP/600/3PH/1800 RPM 19 1.9 CC/REV MFD06 2HP/220/440/3PH/3600 RPM 23 2.3 CC/REV MFA06 2HP/600/3PH/3600 RPM 30 3.0 CC/REV MFG07 2HP/110/220/1PH/1800 RPM MFG08 2HP/110/220/1PH/3600 RPM # 4 PUMP #5 D03 DIRECTIONAL VALVE 2B212 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 12 VOLTS, DIN MFD09 3HP/220/440/3PH/1800 RPM 2B224 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 24 VOLTS, DIN MFA09 3HP/600V/3PH/1800 RPM 2B2110 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 110 VOLTS, DIN MFD10 3HP/220/440/3PH/3600 RPM 2B2220 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 220 VOLTS, DIN MFA10 3HP/600V/3PH/3600 RPM 3C212 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 12 VOLT, DIN 3C224 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 24 VOLT, DIN # 2 RESERVOIR H16 HORIZONTAL 1,6L- 5 1/2'' DIA. 3C2110 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 110 VOLT, DIN H20 HORIZONTAL 2L- 5 1/2'' DIA. 3C2220 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 220 VOLT, DIN H24 HORIZONTAL 2.4L- 5 1/2'' DIA. 3C312 OPEN CENTER SPOOL, 12 VOLT, DIN H28 HORIZONTAL 2.8L- 5 1/2'' DIA. 3C324 OPEN CENTER SPOOL, 24 VOLT, DIN H40 HORIZONTAL 4L-7" DIA. 3C3110 OPEN CENTER SPOOL, 110 VOLT, DIN H42 HORIZONTAL 4.2L-5-1/2" DIA. 3C3220 OPEN CENTER SPOOL, 220 VOLT, DIN H50 HORIZONTAL 5L-7" DIA. 3C412 MOTOR SPOOL, “P” BLOCKED, 12 VOLT, DIN H80 HORIZONTAL 8L-7" DIA. 3C424 MOTOR SPOOL, “P” BLOCKED, 24 VOLT, DIN H90 HORIZONTAL 9L 3C4110 MOTOR SPOOL, “P” BLOCKED, 110 VOLT, DIN H3G HORIZONTAL 3 GAL-5"x8"x11-1/2" 3C4220 MOTOR SPOOL, “P” BLOCKED, 220 VOLT, DIN H5G HORIZONTAL 5 GAL-8"x8"x21" 3C6012 TANDEM CENTER SPOOL, “P” TO “T”, 12 VOLT, DIN V20 VERTICAL 2L- 5 1/2'' DIA. 3C6024 TANDEM CENTER SPOOL, “P” TO “T”, 24 VOLT, DIN V24 VERTICAL 2.4L- 5 1/2'' DIA. 3C60110 TANDEM CENTER SPOOL, “P” TO “T”, 110 VOLT, DIN V28 VERTICAL 2.8L- 5 1/2'' DIA. 3C60220 TANDEM CENTER SPOOL, “P” TO “T”, 220 VOLT, DIN V40 VERTICAL 4L- 7'' DIA. V42 VERTICAL 4,2L- 5 1/2'' DIA V50 VERTICAL 5L- 7'' DIA. Q45/1E MANUAL VALVE 1 SECTION METERING V80 VERTICAL 8L- 7'' DIA. Q45/2E MANUAL VALVE 2 SECTIONS METERING V120 VERTICAL 12L- 10"x10"x8" V180 VERTICAL 18L- 12"x12"x8" #5 MANUAL VALVE Q35 MANUAL VALVE 1 SECTION NO METERING # 6 REMOTE CONTROL # 3 CONTROL VALVE R2 2 BUTTON WITH 10' CABLE R4 4 BUTTON WITH 10' CABLE S12 SOLENOID 12VDC, SINGLE ACTING S24 SOLENOID 24VDC, SINGLE ACTING DLAW THROTTLE & CHECK VALVE (METER OUT) S110 SOLENOID 110AC, SINGLE ACTING DLAW1 THROTTLE & CHECK VALVE (METER IN) S220 SOLENOID 220AC, SINGLE ACTING DYJ REDUCING VALVE ON "P" M MANUAL, SINGLE ACTING DYP RELIEF VALVE "P" TO "T" Q MANUAL, DOUBLE ACTING DYW DUAL RELIEF VALVE "A" & "B" TO "T" N NO VALVE DAYA PILOT OPRATED CHECK VALVE ON "A" A1 MANIFOLD FOR 1 D03 VALVE DAYB PILOT OPRATED CHECK VALVE ON "B" A2P MANIFOLD FOR 2 D03 VALVES, PARALLEL CIRCUIT DAYW DUAL PILOT OPRATED CHECK VALVE A2S MANIFOLD FOR 2 D03 VALVES, SERIES CIRCUIT ASK FOR HY-SPEC QUALITY AC/DC Power Pack Code Builder CODE # 7 D03 MODULAR VALVE Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 7 1. 2. 3. 4. 5. 6. Find cross point of flow (Q) and pressure (P) required on the chart. GPM / 3.7854 = LPM ***** PSI / 14.5 = BAR Select closest pump displacement (Q curves) to the cross point. Doted areas represent Maximum Duty, not recommended to avoid premature damage of unit. In relation to pressure find vertical cross point on the current curve ( I ) of the selected pump. Draw a horizontal line from the current curve ( I ) to the S2 and S3 curves Required current ( A ) can be find between the charts. Vertically below S2 cross point, you will find maximum time the unit can run before motor brushes reach 150°C (Maximum DC motor operating temperature). 7. Vertically below S3 cross point, you will find percentage of a 10 minutes cycle the unit can run. Example: 18 SE 12 16 14 12 10 8 5 l/min 1.0 ~ 3.0 C.C. Pumps 1.5KW / 12V / 210A Max. Power: 2000W Max.Current: 310A 400 300 Q- S2 I- 1 .9 1. 9 S3 200 6 165A 4 100 2 0 30 60 90 120 150 180 210 240 270 P (bar) 124 bar Nominal duty curve Max. duty curve I (A) Q (LPM) How To Read DC Motor and Pump Performance Curves 8 • DC power pack pump flow will decrease as system pressure requirement increase, please refer to flow curve (Q) to find flow reduction. • When application flow and pressure is known you can find current requirement and define duty cycle allowed by following these easy steps: 0 0 5 10 S2 (min) 5 10 15 20 S3 (%) 4.5 min 13 % S2 RATTING =TIME TO REACH 150°C BRUSH TEMPERATURE S3 RATTING =PERCENTAGE OF 10 MINUTES CYCLE For this application we have the following data: flow = 5 LPM, max. pressure= 124 bar. Short time-duty type: S2 Operation at constant load, of short duration, without thermal equilibrium being reached. A no load period follows, sufficient for the motor to return to ambient temperature. Example: S2=4.5 minutes The motor runs continuously for 4.5 minutes, and stops a time sufficient to return to ambient temperature. Intermittent periodic-duty type: S3 Operations which consist of a sequence of uniform cycles (duty cycle 10 minutes) consisiting of a period at constant load and a no load period. Example: S3=13% The motor runs 1.3 minutes and stops 8.7 minutes. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. SE 12 TECHNICAL DATA .0 I -3 I -2 20 I -1. .3 22 330 9 300 5 I -1. Q (LPM) 18 270 16 I -1. 240 0 14 210 12 180 10 150 8 Q1 .0 6 Q- Q-3.0 Q-1.9 60 30 60 90 120 150 180 210 240 270 P (bar) 330 20 300 18 270 3.0 2. 3 Q - 1. 9 Q- I-1. 0 .0 180 150 120 4 60 2 30 30 60 90 I (A) Q (LPM) Q3 I -2. 9 I -1. I -1.5 90 120 150 180 210 240 270 P (bar) Nominal duty curve Max. duty curve ASK FOR HY-SPEC QUALITY 1.0 ~ 3.0 C.C. Pumps 2.0KW / 24V / 110A Max. Power : 2500W Max. Current : 190A 210 .0 I -3 6 0 20 S3 (%) 240 1.5 Q -1 15 TECHNICAL DATA 22 8 10 SE 24 360 10 10 S2 (min) 5 5 S2 RATTING =TIME TO REACH 150°C BRUSH TEMPERATURE S3 RATTING =PERCENTAGE OF 10 MINUTES CYCLE 24 Q- 0 0 Nominal duty curve Max. duty curve Motor Code: I (A) 30 0 12 S2 90 Q-2.3 2 14 S3 120 1.5 4 16 1.0 ~ 3.0 C.C. Pumps 1.5KW / 12V / 210A Max. Power : 2000W Max. Current : 310A 360 24 DC Motor & Pump Performance Curves Motor Code: Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. S2 S3 0 0 10 S2 (min) 5 5 10 15 20 S3 (%) S2 RATTING =TIME TO REACH 150°C BRUSH TEMPERATURE S3 RATTING =PERCENTAGE OF 10 MINUTES CYCLE 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 9 1720 RPM 1720 RPM 5.2 12 6.0 4.8 11 5.5 4.4 5.0 4.0 4.5 3.6 4.0 3.2 3.5 2.8 INPUT HORSE POWER (HP) 6.5 DELIVERY (LPM) 9 8 7 6 5 3.0 4 2.3 1.9 3 1.5 2 1.0 1 0 2.4 3.0 3.0 2.5 2.3 2.0 1.9 30 60 1.6 1.5 1.2 1.0 1.0 0.8 0 90 120 150 180 210 240 270 2.0 1.5 0.4 0.5 30 60 90 120 150 180 210 240 270 Pressure (bar) Pressure (bar) 3450 RPM 3450 RPM 0 (KW) 6.5 5.2 24 6.0 4.8 22 5.5 INPUT HORSE POWER (HP) 26 20 18 16 14 12 10 3.0 8 2.3 1.9 6 1.5 4 1.0 2 0 30 60 0 120 9 150 180 210 240 Pressure (bar) 10 TESTING CONDITIONS 1.0 ~ 3.0 C.C. Pumps OIL VISCOSITY: 46 CST OIL TEMPERATURE: 40°C 13 10 DELIVERY (LPM) AC Motor and Pump Performance Curve • When RPM is known, you can easly find the pump flow delivery; refer to the left chart below. Flow are in LPM, to convert to GPM divide result by 3.7854. • When pump displacement and pressure requirement are known, input horsepower (HP) needed, can be found on the right chart below. Electric motor RPM need to be considered. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 0 7 2 4.4 3.0 5.0 4.5 4.0 3.6 2.3 4.0 3.2 1.9 3.5 3.0 1.5 2.8 2.4 2.0 2.5 2.0 1.0 1.6 1.5 1.2 1.0 0.8 0.5 0.4 0 30 60 90 120 150 180 210 240 270 0 (KW) Pressure (bar) ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. Power Pack Valve Types M Type T P CHECK VALVE c T a BATT. + - P PORT (G 3/8") b bP M RELIEF VALVE S Type T T PORT (G 3/8") T T CHECK P PORT VALVE (G 3/8") P P PORT (G 3/8") FLOW CONTROL VALVE (OPTION) P M RELIEF VALVE T N Type T T PORT (G 3/8") T T PORT CHECK P PORT (G 3/8") VALVE (G 3/8") P * P PORT (G 3/8") P M RELIEF VALVE T T A Type T PORT (G 3/8") T A P B ADAPTOR CHECK VALVE G P T M P T T RELIEF VALVE T PORT (G 3/8") A Type + Cetop 03 A B T ADAPTOR "A" KIT B A P G P M T RELIEF VALVE T PORT (G 3/8") P T T * To convert all G3/8 port to 3/8 NPT, use adaptor # HYSW800523 except “N” type main “T” port use # HYSW880202-1 ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 11 A-Type Manifold Function M8 x 1.25 SHCS STAGES 1 2 3 4 LENGTH 50 100 150 200 TOP SUBPLATE MANIFOLD TYPE ORDER NO. W850502-Q1 TOP SUBPLATE MANIFOLD T A PORT G1/4" A MOUNTING SURFACE CETOP 03 B PORT G1/4" B P T A PORT G1/4" A M5 x 0.8 TYP. B PORT G1/4" B NOTE: THIS MANIFOLD MUST BE USED FROM 1 TO 4 STAGES MODULAR SUBPLATE MANIFOLDS TYPE ORDER NO. W850501-Q SERIES CIRCUIT SUBPLATE MANIFOLDS W850502-Q PARALLEL CIRCUIT SUBPLATE MANIFOLDS W850503-Q SINGLE-ACTING CIRCUIT SUBPLATE MANIFOLDS (THESE MANIFOLDS CANNOT BE USED WITHOUT NOTE: "TOP SUBPLATE MANIFOLD") P T P ADAPTER "A" KIT ((W850500-R) HYSW880203) G PORT G1/4" P PORT G3/8” NOT USED WITH "A" TYPE A B A B W850502-Q1 MOUNTING PAD "B" W850502-Q T M10xP1.5-4holes P STANDARD RELIEF VALVE (OR LOW-NOISE RELIEF VALVE) T PORT G3/8" MOUNTING PAD "D" VIEW FROM MOTOR SIDE W850500-R G T M T MOUNTING PAD "C" EXAMPLE : 2 STAGES PARALLEL CIRCUIT M10xP1.5-4holes • Hy-Spec Power Packs offer flexibility. Multiple options can be configured to cover a wide rande of applications. • • 12 Use adaptor # HYSW800523 to convert from G3/8 port to 3/8 NPT. Use adaptor # HYSW800523-3P to convert from G1/4 port to 1/4 NPT. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. OPTION P/N AND DESCRIPTION SYMBOL STACK HEIGHT 2B* 3C* See p.17 for D03 directional valve model code 45mm DLAW DLA02-W-31.5-70 Throttle with free flow check valve meter out 40mm DLAW1 DLA02-W1-31.5-70 Throttle with free flow check valve meter in 40mm DYJ DYJ02-P-21-70 Pressure reducing valve 40mm DYP DY02-P31.5-70 Relief valve 40mm DYW DY02-W-31.5-70 Dual port relief valve 40mm DAYA DAY02-A1-31.5-70 Pilot operated check valve on A 40mm DAYB DAY02-B1-31.5-70 Pilot operated check valve on B 40mm DAYW DAY02-W1-31.5-70 Dual Pilot operated check valve 40mm ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. MOUNTING HOLE THREAD D03 Modular Valve Options On “A” type manifold, in addition to D03 directional valve, modular valve options can be installed for circuit flexibility. For proper mounting bolt length add 40 mm to the height listed in the chart per modular valve. M5 x 0.8 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 13 Electrical Motor W AD AC L H HC AC / DC Power Pack - General Dimensions Add up “L” dimensions of reservoir and electric motor plus 32 mm (manifold) to get typical overall length of power pack. For all other dimension, please contact our tehchnical support department. A Unit: mm ORDERING CODE REF. AC MOTOR P/N MFD01 MFD02 MFG03 MFG04 MFD05 MFA05 MFD06 MFA06 MFG07 MFG08 MFD09 MFA09 MFD10 MFA10 HYSW850201-3D HYSW850202-3D HYSW850203-1G HYSW850204-1G HYSW850205-3D HYSW850205-1A HYSW850206-3D HYSW850206-1A HYSW850207-1G HYSW850208-1G HYSW850209-3D HYSW850209-1A HYSW850210-3D HYSW850210-1A HP VOLTAGE 220/440 1 110/220 2 220/440 600 220/440 600 110/220 3 220/440 600 220/440 600 B RPM A 1800 3600 1800 3600 AD B H HC 142 L W 258 147.5 1800 278 145 3600 140 1800 3600 100 89 178 237 147.5 1800 298 142 3600 A DC L ORDERING CODE REF. SE12 SE24 14 DC MOTOR P/N HYSW820612 HYSW821012 HYSW820624 HYSW821024 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m POWER VOLTAGE 1500W 12 2000W 24 TYPE A L Ø 114 170 EARTH RETURN (MOTOR WITH 1 TERMINAL) INSULATE RETURN (MOTOR WITH 2 TERMINALS) EARTH RETURN (MOTOR WITH 1 TERMINAL) INSULATE RETURN (MOTOR WITH 2 TERMINALS) ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. ORDERING CODE REF. RESERVOIR P/N H16 HYSW880106 170 1.6 H20 and V20 HYSW880107 205 2.0 H24 and V24 HYSW880108 H28 and V28 HYSW880109 285 2.8 H42 and V42 HYSW880110 405 4.2 DIAMETER L (mm) A (mm) VOLUME (litters) A 40 245 2.4 140.0 140 L ORDERING CODE REF. RESERVOIR P/N H40 and V40 HYSW880112 245 4.0 H50 and V50 HYSW880113 285 5.0 H80 and V80 HYSW880114 405 8.0 H90 HYSW800147 445 9.0 L (mm) A (mm) A 87 180.0 180 VOLUME (litters) 140.0 DIAMETER H3G HYSW800151-P 295 HYSW880125 B (mm) C (mm) 210 25 20 VOLUME (litters) 12 (3.0 GAL) 545 10.0x2 Holes C B 20 (5.0 GAL) 4.0 20.0 140.0 H5G A (mm) 100.0 L (mm) A RESERVOIR P/N 10.0 25.0 200.0 L HYSW880118 ASK FOR HY-SPEC QUALITY 125 280 210 E (mm) F (mm) G (mm) VOLUME (litters) 250 250 300 12 A (mm) B (mm) C (mm) D (mm) 120 150 330 260 E (mm) F (mm) G (mm) VOLUME (litters) 300 300 350 18 Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. 25.0 B 100 A 10.0x4 Holes C D (mm) 30.0 Option 30.0 C (mm) 25.0 B (mm) D E 140.0 245.0 V180 HYSW880117 A (mm) 212.0 V120 RESERVOIR P/N 207.0 ORDERING CODE REF. 33.0 ORDERING CODE REF. 50.0 L AC / DC Power Pack - General Dimensions Reservoir F G 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 15 Power Pack - Parts CODE SE12 SE24 MFD01 MFD02 MFG03 MFG04 MFD05 MFA05 MFD06 MFA06 MFG07 MFG08 MFD09 MFA09 MFD10 MFA10 H16 H20 H24 H28 H40 H42 H50 H80 H90 H3G H5G V20 V24 V28 V40 V42 V50 V80 V120 V180 S12 SMOR S24 S110 S220 M N A1 A2P A2S 16 DESCRIPTION P/N # 1 - MOTOR 12 VOLT, EARTH RETURN (1 TERMINAL) MOTOR MAGNETIC STARTER KIT FOR HYSW820612 12 VOLT, INSULATE RETURN (2 TERMINALS) MOTOR MAGNETIC STARTER KIT FOR HYSW821012 24 VOLT, EARTH RETURN (1 TERMINAL) MOTOR MAGNETIC STARTER KIT FOR HYSW820624 24 VOLT, INSULATE RETURN (2 TERMINALS) MOTOR MAGNETIC STARTER KIT FOR HYSW821024 1HP/220/440/3PH/1800 RPM, MOTOR 1HP/220/440/3PH/3600 RPM, MOTOR 1HP/110/220/1PH/1800 RPM, MOTOR 1HP/110/220/1PH/3600 RPM, MOTOR 2HP/220/440/3PH/1800 RPM, MOTOR 2HP/600/3PH/1800 RPM, MOTOR 2HP/220/440/3PH/3600 RPM, MOTOR 2HP/600/3PH/3600 RPM, MOTOR 2HP/110/220/1PH/1800 RPM, MOTOR 2HP/110/220/1PH/3600 RPM, MOTOR 3HP/220/440/3PH/1800 RPM, MOTOR 3HP/600V/3PH/1800 RPM, MOTOR 3HP/220/440/3PH/3600 RPM, MOTOR 3HP/600V/3PH/3600 RPM, MOTOR # 2 - RESERVOIR HORIZONTAL 1,6L- 5 1/2'' DIA. HORIZONTAL 2L- 5 1/2'' DIA. HORIZONTAL 2.4L- 5 1/2'' DIA. HORIZONTAL 2.8L- 5 1/2'' DIA. HORIZONTAL 4L-7" DIA. HORIZONTAL 4.2L-5-1/2" DIA. HORIZONTAL 5L-7" DIA. HORIZONTAL 8L-7" DIA. HORIZONTAL 9L-7" DIA. HORIZONTAL 3 GAL-5"x8"x11-1/2" HORIZONTAL 5 GAL-8"x8"x21" VERTICAL 2L- 5 1/2'' DIA. VERTICAL 2.4L- 5 1/2'' DIA. VERTICAL 2.8L- 5 1/2'' DIA. VERTICAL 4L- 7'' DIA. VERTICAL 4,2L- 5 1/2'' DIA VERTICAL 5L- 7'' DIA. VERTICAL 8L- 7'' DIA. VERTICAL 12L- 10"x10"x8" VERTICAL 18L- 12"x12"x8" # 3 - CONTROL OPTION SOLENOID 12VDC, SINGLE ACTING SOLENOID 12VDC, SINGLE ACTING W/ MANUAL OVERIDE SOLENOID 24VDC, SINGLE ACTING SOLENOID 110AC, SINGLE ACTING SOLENOID 220AC, SINGLE ACTING MANUAL, SINGLE ACTING SPECIAL ADAPTOR FOR "P" PORT (3/8 BSP-M TO 3/8 NPT-F) SPECIAL ADAPTOR FOR "T" PORT (3/8 BSP-M TO 3/8 NPT-F) MANIFOLD FOR 1 D03 VALVE (END COVER) SPECIAL ADAPTOR FOR "A" & "B" PORT (1/4 BSP-M TO 1/4 NPT-F) MANIFOLD FOR 2 D03 VALVES (PARALLEL CIRCUIT) MANIFOLD FOR 2 D03 VALVES (SERIES CIRCUIT) 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m HYSW820612 HYS880103 HYSW821012 HYSW880101 HYSW820624 HYSW880104 HYSW821024 HYSW880102 HYSW850201-3D HYSW850202-3D HYSW850203-1G HYSW850204-1G HYSW850205-3D HYSW850205-1A HYSW850206-3D HYSW850206-1A HYSW850207-1G HYSW850208-1G HYSW850209-3D HYSW850209-1A HYSW850210-3D HYSW850210-1A HYSW880106 HYSW880107 HYSW880108 HYSW880109 HYSW880112 HYSW880110 HYSW880113 HYSW880114 HYSW800147 HYSW800151-P HYSW880125 HYSW880107 HYSW880108 HYSW880109 HYSW880112 HYSW880110 HYSW880113 HYSW880114 HYSW880117 HYSW880118 HYSW880493 HYSLSV2-08-2NCP-M-ID HYSW880494 HYSW800495 HYSW800496 HYSW880201 HYSW800523 HYSW880202-1 HYSW850502-Q1 (2x) HYSW800523-3P HYSW850502-Q + HYSW850502-Q1 HYSW850501-Q + HYSW850502-Q1 ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. DESCRIPTION # 3 - CONTROL OPTION (Cont’d) MANIFOLD FOR 3 D03 VALVES (PARALLEL CIRCUIT) MANIFOLD FOR 3 D03 VALVES (SERIES CIRCUIT) MANIFOLD FOR 4 D03 VALVES (PARALLEL CIRCUIT) MANIFOLD FOR 4 D03 VALVES (SERIES CIRCUIT) # 4 - PUMP 10 1.0 CC/REV 15 1.5 CC/REV 19 1.9 CC/REV 23 2.3 CC/REV 30 3.0 CC/REV 40 4.0 CC/REV 51 5.1 CC/REV 62 6.2 CC/REV 73 7.3 CC/REV # 5 - D03 DIRECTIONAL VALVE 2B212 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 12 VOLTS, DIN 2B224 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 24 VOLTS, DIN 2B2110 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 110 VOLTS, DIN 2B2220 SINGLE ACTING SPOOL, 2 POSITION, SPRING OFFSET TO “A”, 220 VOLTS, DIN 3C212 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 12 VOLT, DIN 3C224 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 24 VOLT, DIN 3C2110 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 110 VOLT, DIN 3C2220 CLOSED CENTER SPOOL, ALL PORTS BLOCKED, 220 VOLT, DIN 3C312 OPEN CENTER SPOOL, 12 VOLT, DIN 3C324 OPEN CENTER SPOOL, 24 VOLT, DIN 3C3110 OPEN CENTER SPOOL, 110 VOLT, DIN 3C3220 OPEN CENTER SPOOL, 220 VOLT, DIN 3C412 MOTOR SPOOL, “P” BLOCKED, 12 VOLT, DIN 3C424 MOTOR SPOOL, “P” BLOCKED, 24 VOLT, DIN 3C4110 MOTOR SPOOL, “P” BLOCKED, 110 VOLT, DIN 3C4220 MOTOR SPOOL, “P” BLOCKED, 220 VOLT, DIN 3C6012 TANDEM CENTER SPOOL, “P” TO “T”, 12 VOLT, DIN 3C6024 TANDEM CENTER SPOOL, “P” TO “T”, 24 VOLT, DIN 3C60110 TANDEM CENTER SPOOL, “P” TO “T”, 110 VOLT, DIN 3C60220 TANDEM CENTER SPOOL, “P” TO “T”, 220 VOLT, DIN # 5 - MANUAL VALVE Q35 MANUAL VALVE 1 SECTION NO METERING Q45/1E MANUAL VALVE 1 SECTION METERING Q45/2E MANUAL VALVE 2 SECTIONS METERING # 6 - REMOTE CONTROL R2 2 BUTTON WITH 10' CABLE R4 4 BUTTON WITH 10' CABLE # 7 - D03 MODULAR VALVE DLAW THROTTLE & CHECK VALVE (METER OUT) DLAW1 THROTTLE & CHECK VALVE (METER IN) DYJ REDUCING VALVE ON "P" DYP RELIEF VALVE "P" TO "T" DYW DUAL RELIEF VALVE "A" & "B" TO "T" DAYA PILOT OPRATED CHECK VALVE ON "A" DAYB PILOT OPRATED CHECK VALVE ON "B" DAYW DUAL PILOT OPRATED CHECK VALVE MISCELLANEOUS PART NEMA 143TC-145TC BELL HOUSING 7/8 MUFF COUPLING (143TC-145TC) NEMA 56C BELL HOUSING 5/8 MUFF COUPLING (56C) * Included rectified DIN connector must be used with 110 VAC / 220 VAC valve. A3P A3S A4P A4S ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. P/N (2x) HYSW850502-Q + HYSW850502-Q1 (2x) HYSW850501-Q + HYSW850502-Q1 (3x) HYSW850502-Q + HYSW850502-Q1 (3x) HYSW850501-Q + HYSW850502-Q1 HYSW880301 HYSW880302 HYSW880303 HYSW880304 HYSW880305 HYSW880306 HYSW880307 HYSW880308 HYSW880309 FW-02-2B2-D12-Z5L-60 02-0322012 HYS FW-02-2B2-D24-Z5L-60 02-0322024 HYS FW-02-2B2-B110-Z5L-60 02-0322110 HYS * FW-02-2B2-B220-Z5L-60 02-0322220 HYS * FW-02-3C2-D12-Z5L-60 02-0332012 HYS FW-02-3C2-D24-Z5L-60 02-0332024 HYS FW-02-3C2-B110-Z5L-60 02-0332110 HYS * FW-02-3C2-B220-Z5L-60 02-0332220 HYS * FW-02-3C3-D12-Z5L-60 02-0333012 HYS FW-02-3C3-D24-Z5L-60 02-0333024 HYS FW-02-3C3-B110-Z5L-60 02-0333110 HYS * FW-02-3C3-B220-Z5L-60 02-0333220 HYS * FW-02-3C4-D12-Z5L-60 02-0334012 HYS FW-02-3C4-D24-Z5L-60 02-0334024 HYS FW-02-3C4-B110-Z5L-60 02-0334110 HYS * FW-02-3C4-B220-Z5L-60 02-0334220 HYS * FW-02-3C60-D12-Z5L-60 02-0336012 HYS FW-02-3C60-D24-Z5L-60 02-0336024 HYS FW-02-3C60-B110-Z5L-60 02-0336110 HYS * FW-02-3C60-B220-Z5L-60 02-0336220 HYS * Power Pack - Parts CODE HYSQ35-F7SN-103/A1/M1-SAE HYSQ45/1E-F1SN-103/A1/M1-F3D-S-SAE HYSQ45/2E-F1SN-2X103/A1/M1-F3D-S-SAE HYST90009-3P HYST90012-3P HYSDLA02-W-31.5-70 HYSDLA02-W1-31.5-70 HYSDYJ02-P-21-70 HYSDY02-P-31.5-70 HYSDY02-W-31.5-70 HYSDAY02-A1-31.5-70 HYSDAY02-B1-31.5-70 HYSDAY02-W1-31.5-70 HYSW870317 HYSW870306 HYSW870317-1 HYS870306-2P 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 17 How Connect Various Wires to DC Hydraulic Power Pack appendix B-5 18 How to Connect Various Wires to the DC Hydraulic Power Pack (Ⅰ) AWG Max Current Specifications RETURN MOTOR) Wire Size (INSULATE Amperage When you connect the power source (battery), you must use the correct wire size for amperage requirement of the circuit to prevent the wire from over heating. 1.Before using the DC Hydraulic Power Pack, read all instruc 0000 310 and examine diagrams. The motor needs a large current, so correct required. 000 wires are 250 • Ambient Refer Power Wires) temperature: 25 ~ 30oC 00 to Chart: (Battery 190 Current(A) 0 See performance curve on page 9 for amperage requirement. 1 90(A) 2120(A) 180(A) Wire Connection Diagram Old Design • • 2 Working time: approx 30 sec. Please Note Wire length: 1m Diameter of wire 150 Ambient Temperature: 1195.5(mm ) 2 948.0(mm ) 25~30° C 2 Working time: 14 (mm ) approx. 30 sec. Wire Connection Diagram 22 (mm ) Wire length: 1m 280(A) 30 (mm ) New Design 2 230(A) 2 2 330(A) 38 (mm ) 2.Wire Connection Diagram (INSULATE RETURN MOTOR) (INSULATE RETURN MOTOR) Max. Tighten Torque 36 lbf · in(4.1 N · m) Power Wires How to Connect Various Wires to the DC Hydraulic Power Pack (Ⅱ) (EARTH RETURN MOTOR) Max. Tighten Torque 16 lbf " in(1.8 N" m) Oil Tank Small Current Wire 1.Before using the DC Hydraulic Power Pack, read all instructions and examine diagrams. The motor needs a large current, so correct wires are required. Small Current Wire Refer to Chart: (Battery Power Wires) Current(A) Control Switch Power Wires Up Battery Solenoid Valve Small Current Wire (Earth-Return Line) Max. Tighten Torque 36 lbf " in(4.1 N" m) Small Current Wire Small Current Wire appendix B-6 Power Wires Max. Tighten Torque 16 lbf · in(1.8 N · m) Down 2 90(A) 5.5(mm ) 120(A) 8.0(mm ) 180(A) 14 (mm ) 230(A) Small Current Wire Diameter of wire 280(A) 2 2 a ll Control Switch Please Note rre n Cu tW Up ir Ambient eTemperature: Down 25~30° C Working time: Small Current Wire 2 approx. 30 sec. 2 Wire length: 1m 22 (mm ) Small Current Wire 30 (mm ) Solenoid Valve Sm 2 330(A) (mm ) * The customer must choose38the proper control wire (small current) to ensure they can hold Diagram 2 Amps andRETURN above. MOTOR) 2.Wire Connection (EARTH (EARTH RETURN MOTOR) Max. Tighten Torque 36 lbf · in(4.1 N · m) B.401.105 Rev.120110 Max. Tighten Torque 16 lbf · in(1.8 N · m) Power Wires Power Wires Max. Tighten Torque 16 lbf " in(1.8 N" m) Max. Tighten Torque 36 lbf " in(4.1 N" m) Oil Tank Small Current Wire (Earth-Return Line) Small Current Wire Power Wires Small Current Wire Battery Solenoid Valve Small Current Wire Control Switch Up Small Current Wire Down Control Switch Up Down Small Current Wire Small Current Wire Small current wire must hold 2 Amps minimum. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m Small Current Wire Solenoid Valve * The customer must choose the proper wire (small ASKcontrol FOR HY-SPEC QUALITYcurrent) to ensure they can hold 2 Amps and above. Note actual products may differ from photos shown in this brochure. Rev.120110 Product availability and specifications are subject to change without notice. B.401.106 HY-SPEC WARRANTY ALTERATION, AN ACCIDENT, IMPROPER OPERATION OR MAINTENANCE, ABNORMAL CONDITIONS OR THE WEAR FROM NORMAL USE. HYDRAULIC AND GAS ENGINE PRODUCTS LIMITED WARRANTY HY-SPEC HYDRAULIK, WARRANTS ITS HYDRAULIC PRODUCTS AGAINST DEFECTS IN DESIGN, MATERIAL AND WORKMANSHIP FOR A PERIOD OF 12-MONTHS FROM THE DATE OF SALE. HY-SPEC HYDRAULIK WILL REPLACE ANY PART OF ITS PRODUCTS, FREE OF CHARGE, IF AFTER INSPECTION BY HY-SPEC HYDRAULIK THE PART IS DEEMED A MANUFACTURING DEFECT. HY-SPEC HYDRAULIK, WARRANTS ITS GAS ENGINE PRODUCTS AGAINST DEFECTS IN DESIGN, MATERIAL AND WORKMANSHIP FOR THE FOLLOWING PERIOD FROM THE DATE OF SALE: - 12 MONTHS : CONSUMER USE** - 3 MONTHS : COMMERCIAL USE*** HY-SPEC HYDRAULIK SHALL NOT BE LIABLE FOR LOSS OF TIME, MANUFACTURING COSTS, LABOUR, TRANSPORT, MATERIAL, LOSS OF PROFITS, CONSEQUENTIAL DAMAGES (DIRECT OR INDIRECT), AS A RESULT OF DEFECTIVE PRODUCTS. HY-SPEC HYDRAULIK’S RESPONSIBILITY WILL BE LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT OR THE REIMBURSEMENT OF THE PRICE PAID AT THE TIME IT WAS ORDERED. ANY WARRANTY CLAIM MUST BE PRESENTED WITHIN 30 DAYS OF THE MANUFACTURING DEFECT DISCOVERY. SHIPPING RETURN CHARGES ARE AT THE CUSTOMER’S EXPENSE. ** CONSUMER USE MEANS PERSONAL USE BY A CONSUMER. *** COMMERCIAL USE MEANS ALL OTHERS USERS, INCLUDING COMMERCIAL, INCOME GENERATING OR RENTAL. THIS WARRANTY DOES NOT APPLY TO ANY PRODUCT WHICH HAS BEEN SUBJECT TO UNAUTHORIZED MODIFICATION, REPAIR OR For more information or OEM requests 1.866.546.3267 To find a Hy-Spec retailer near you www.Hy-Spec.com ASK FOR HY-SPEC QUALITY Note actual products may differ from photos shown in this brochure. Product availability and specifications are subject to change without notice. 1 . 8 6 6 . 5 4 6 . 3 2 67 w w w. H y- s p e c . c o m 19 HY-SPEC CATALOGUE - AC/DC POWER PACKS AC/DC Power Packs Typical Equipment Fork Lifts Loaders Presses Tractors Typical Industries Agriculture Construction Forestry Mining HY-SPEC HYDRAULIK specializes in the import and export of a wide range of high quality hydraulic components such as: agricultural, telescopic and utility cylinders; directional control valves; gas engines; power packs and much more. The HY-SPEC brand name stands for high quality hydraulic components. These products are manufactured around the world to our high specifications, which are established by our engineering department. The HY-SPEC team members have been chosen for their experience and are trained to give professional and efficient service, which you can depend on. Their experience totals over 100 years in the hydraulic industry. They work closely with our customers to provide the best solution for their application. 1.866.546.3267 www.Hy-Spec.com [email protected] Your distributor HY-SPEC IS A WAJAX INDUSTRIAL COMPONENTS BRAND. HY-SPEC-CATALOGUE-AC-DC-POWER-PACKS-12-06-2012