NETAPP HARDWARE UNIVERSE

Transcription

NETAPP HARDWARE UNIVERSE
ADAPTER CARDS
COMMON CABLES
17
Front View
14
3U
Rack Height
24
3U
24
4U
24
4U
48
2U
5.25 in.
(13.3 cm)
-
4U
Depth DS14mk4 FC: 20 in. (50.8 cm)
Depth DS14mk2 AT: 22 in. (55.2 cm)
17.6 in. (44.7 cm)
450GB SAS
6.00A
600GB SAS
5.98A
1.0TB SATA
4.41A
450GB SAS 4.41A
1.0TB SATA
4.41A
2.0TB SATA
4.72A
600GB SAS 4.22A
3.0TB SATA
4.95A
2.0TB SATA
4.72A
900GB SAS 4.22A
3.0TB SATA
4.95A
(mixed SSD
+ SATA support)
100GB SSD
699
900GB SAS
1,127
1.0TB SATA
1,499
450GB SAS 1,461
2.0TB SATA
1,599
600GB SAS 1,441
3.0TB SATA
1,690
900GB SAS 1,441
450GB SAS
2,047
600GB SAS
2,028
1.0TB SATA
1,499
2.0TB SATA
1,599
3.0TB SATA
1,690
X556A-R6 (2x PSU)
X557A-R6 (4x PSU)
X518A-R6
Supported
-
The FibreBridge 6500N
provides bridging
between FC and SAS
protocols for Stretch
and Fabric MetroCluster
configurations enabling
backend connectivity
to DS2246 and DS424x
disk shelves. 2 FibreBridges are required to
support a single shelf
stack (4 FibreBridges
minimum per MetroCluster). Each FibreBridge
provides 2x 8Gb FC
ports and 1x 6Gb SAS
port (second SAS portis
unused).
X568A-R6
X519A-R6
X521A-R6
DS2246-1005-12S-QS-R5 (450GB)
DS2246-1007-12S-QS-R5 (600GB)
DS2246-1014-12S-QS-R5 (600GB)
DS2246-10.8TB-QS-R5 (900GB)
DS4246-0712-12A-QS-R6 (1.0TB)
DS4246-0724-12A-QS-R6 (2.0TB)
DS4246-0736-12A-QS-R6 (3.0TB)
DS4246-0724-24A-QS-R6 (1.0TB)
DS4246-0748-24A-QS-R6 (2.0TB)
DS4246-0772-24A-QS-R6 (3.0TB)
DS4246-0772-24N-QS-R6 (3.0TB)
DS2246-1011-24S-QS-R5 (450GB)
DS2246-1014-24S-QS-R5 (600GB)
DS4486-144TB-QS-R5
DS2246-1014-24N-QS-R5 (600GB) NSE
-
-
-
P
Op - LC
Fixed Optics
Non-removable
PCIe
X1132A-R6
TARGET/DISK/TAPE 4-Port 8Gb
-
-
-
-
-
-
AT-FCX
X5612A-R6
-
Supported
-
-
-
-
-
IOM3
X5712A-R6
-
-
Supported
-
-
-
-
IOM6
X5713A-R6
-
-
-
Supported
Supported
Supported
-
8.1.1
7.3.4, 8.0.1, 8.1.1
8.1.1
8.1
P
P
P
Scan the QR Code to learn more about
the NetApp Hardware Universe site.
3.4 in.
(8.5 cm)
SSD – Solid State Drives
ST – Straight Tip Connector
TOE –TCP/IP Offload Engine
NOTES
10 NVMEM on select FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
6.87 in.
result in less memory for available
to cm)
Data ONTAP.
(17.4
1 HA values shown reflect a Controller+IOXM (CI) configuration.
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000 bytes) and is derived based on the type,
size, and number of drives.
4
6
6
2
PCIe
X2054A-R6
DISK/TAPE 4-Port 4Gb
Op - LC
Fixed Optics
Non-removable
7.3, 8.0
12
12
4
6
6
2
X2055A-R6
DISK 2-Port 4Gb
Op - LC
Fixed Optics
Non-removable
7.3, 8.0, 8.1
X2056-R6
TARGET/DISK/TAPE 4-Port 8Gb
Op - LC
X1150A-R6
TARGET/DISK/TAPE 2-Port 8Gb
Op - LC
X6588-R6
(AFBR-57D7APZ or FTLF8528P2BNV)
14 Requires Data ONTAP 8.1 release or higher.
5 AC Power values shown are worst-case and reflect system running on
one PSU, high fan speed, and power distributed over one power cord.
Please refer to the Site Requirements Guide on the NetApp Support site:
support.netapp.com for typical case values.
PCIe
X1038A-R6
NIC 2-Port GbE
Op - LC
Fixed Optics
Non-removable
7.3, 8.0, 8.1
PCIe
X1048A-R6
NIC 4-Port GbE
Op - LC
Fixed Optics
Non-removable
8.1.1
PCIe
X1049B-R6
NIC 4-Port GbE
Cu - RJ45
-
7.3.5, 8.0.2, 8.1
16 Minimum Data ONTAP Support - 7.3.5.1, 8.0.1P5, and 8.0.2 and later;
Depth: 27 in. (68.6 cm)
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS ports Storage Support - DS224x & DS424x.
+
X1107A-R6
NIC 2-Port 10GbE
Op - LC
X6563-R6
(PLRXPL-SC-S43-42B or FTLX8571D3BCL)
17 The DS14mk2 AT disk shelf and disks will not be shipping in
Production starting 01/02/2013. The AT dongle that is not RoHS
in.
2012 compliant (RoHS currently 1.69
for Europe).
Only spares of shelves
cm)
and spare hard drives FRUs can(4.3
be shipped
out in 2013.
+
9 100 LUNs from one array using one array LUN group. Combined LUN
and NetApp disk can total 240 devices.
10 Gigabit Ethernet
SFP+
Expansion Slot
Mezzanine
netapp.com/techontap/community
FAS2240-4
Expansion Slot
PCI-X
FAS2240-2
4Gb Fibre Channel
SFP
+
8Gb Fibre Channel
SFP+
Serial-Attached SCSI
QSFP
+
Alternate Control Path
RJ45
P
Serial Console
RJ45
HA Interconnect
IB4X
Remote Management
RJ45
HA Interconnect
QSFP
Q
HA Interconnect
SFP+
Feedback and questions can be sent to:
+
M
20 / 40 / 40 / 68
- / - / 70TB
- / - / 90TB
16TB / 50TB / 50TB
15 / 30 / 30 / 51
12.5 / 25 / 25 / 42
- / - / 60TB
10 / 20 / 20 / 34
Max Backend
LUNs
1440
1440
1200
960
720
600
480
100
Environmental
HA Pair / Single Controller
V-Series
Specifications
240
(HA / Single)
BTU/hr6
(HA / Single)
IBM
· DS8700, DS8800
· DS5xx0
· DS4700, DS4800
· XIV Gen2 & Gen3
HDS
· VSP
· AMS
· USP-V
· HUS
3PAR
· P10000
· T400, T800
· F200, F400
- / - / 180TB
- / - / 60TB
- / - / 60TB
- / 10 / 10 / 17
480
- / - / 60TB
- / - / 60TB
-/5/5/6
- / - / 60TB
-/5/5/6
144
(24 Int + 120 Ext)
-/2/2/-
144
(24 Int + 120 Ext)
6U / 3U
3U / 3U
4U / 4U
2U / 2U
2U / 2U
251.4 (114 kg)
125.7 lbs (57 kg)
251.4 (114 kg)
125.7 lbs (57 kg)
130.1 lb. (59 kg)
99.2 lb. (45 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
149 lb. (67.6 kg)
74.5 lb. (33.8 kg)
79.5 lb. (36.1 kg)
67.3 lb. (30.5 kg)
107.1 lbs (48.7 kg)
102 lbs (46.4 kg)
55.4 lbs (25.2 kg)
50.4 lbs (22.9 kg)
62.4 lbs (28.3 kg)
57.8 lbs (26.2 kg)
- / 5A @100V
4.8A / 2.5A @200V
6280 / 3140 @100V
5974 / 2987 @200V
- / 1673 @100V
3174 / 1639 @200V
4/2
64-bit quad-core
4/2
64-bit quad-core
7.28A / 5.47A @100V
3.58A / 2.73A @200V
2485 / 1867 @100V
2413 / 1820 @200V
4/2
64-bit dual-core
10.94A / 5.47A @100V
5.46A / 2.73A @200V
6.37A / 5.01A @100V
3.15A / 2.5A @200V
3734 / 1867 @100V
3640 / 1820 @200V
2168 / 1707 @100V
2116 / 1632 @200V
4/2
64-bit quad-core
Slot 5
Slot 6
+
P
+
+ +
+
+
614
214
PCIe
X1139A-R6
Unified Target 2-Port 10Gb
Op - LC
SFP module pre-installed
(PLRXPL-VC-S43-21-N) No optical FRU available
7.3.2, 8.0.1, 8.1
1013
1013
4
6
6
2
Cu - SFP+
X1160A-R6
NIC 2-Port 10GbE
Cu - SFP+
PCIe
X2028A-R6
TAPE 2-Port SCSI-LVD/SE
PCIe
X2065A-R6
SAS, 4-Port, 6Gb
X2067-R6
SAS, 4-Port, 6Gb
7.3.2, 8.0.1, 8.1
Approved Twinax Cables
X6589-R6
(AFBR-703SDZ-NA2 or FTLX8571D3BCL-(NQ)
10.2 in.
(25.86 cm)
Slot 7
Slot 13
Slot 8
Slot 14
Slot 9
2/1
64-bit quad-core
6.37A / 3.71A @100V
3.15A / 1.96A @200V
2168 / 1256 @100V
2116 / 1229 @200V
2/1
64-bit quad-core
6.27A / 4.22A @100V
3.11A / 2.11A @200V
2137 / 1437 @100V
2089 / 1403 @200V
2/1
64-bit dual-core
5.97A / 5.36A @100V
3.01A / 2.70A @200V
2031 / 1820 @100V
1775 / 1983 @200V
2/1
64-bit dual-core HT
4.45A / 3.92A @100V
2.23A / 1.92A @200V
4.32A / 5.31A @100V
2.59A / 2.14A @200V
1536 / 1332 @100V
1434 / 1294 @200V
4
6
6
2
Cu - QSFP
-
7.3.2, 8.0, 8.1
6
6
4
6
6
2
2/1
64-bit dual-core HT
PCIe
X1927A-R6
MetroCluster™ FC-VI 2-Port 8Gb
PCIe
X3149-R6
NVRAM8 4GB
Op - LC
Cu-QSFP
X1142A-R6
SnapMirror® over FC 2-Port 8Gb
Op - LC
SFP module pre-installed
(FTLF8528P2BCV-QL) No optical FRU available
FC Ports
8-32 / 4-16
8Gb SFP+7
(HA / Single)
SAS Ports
(HA / Single)
Data ONTAP
0-8 / 0-4
6Gb QSFP8
4/2
6Gb QSFP
BTU – British Thermal Unit
Cu – Copper Connector
EOA – End of Availability
4/2
4/2
4Gb SFP EOS – End of4Gb
SFP
Support
ESH – Electronically Switched Hub
FAS – Fabric-Attached Storage
4/2
4/2
Channel Protocol
6Gb QSFP FCP – Fibre 6Gb
QSFP
FC – Ferrule Connector
FC – Fibre Channel
4/2
6Gb QSFP
®
8.0.1, 8.1
8.0.1, 8.1
P
Dimensions
Weight
H: 1.69 in (4.3 cm)
W: 17.5 in (44.5 cm)
D: 20 in. (50.8 cm)
1U
H: 1.69 in (4.3 cm)
W: 17.5 in (44.5 cm)
D: 20 in. (50.8 cm)
X6589-R6
10Gb SFP+
X6588-R6
8Gb SFP+
X6539-R6
4Gb SFP
22.5 lbs (10.2 kg)
12 lbs (5.45 kg)
Amps
(Worst-case)
1.28A @100-120V
.82A @200-240V
0.58A @100-120V
0.37A @200-240V
QSFP
7.3.5, 8.0.1, 8.1
FAS2240-2
8.1.2
7.3.5, 8.0.1, 8.1
7 in.
(17.8 cm)
M
P
SFP module pre-installed
(FTLF8528P2BCV-QL) No optical FRU available
2/1
mezzanine
1.5GB / 768MB
NVMEM
1.5GB / 768MB
NVMEM
2/1
mezzanine
-
-
7.3.5, 8.0.2, 8.1
PCIe
X1971A-R5
Flash Cache - 512GB
-
-
7.3.5, 8.0.2, 8.1
X1972A-R5
Flash Cache - 1TB
-
8 / 4 GbE RJ45
8 / 4 GbE RJ45
FRU – Field Replacement Unit
0-4 / 0-2 10GbE
0-4 / 0-2 10GbE
GbE – Gibabit Ethernet
HA – High Availability
0-4 / 0-2HSSDC – High-Speed
0-4 / Serial
0-2
Data Connector 8Gb SFP+
8Gb SFP+
HT – Hyper-Threading
IB4X – InfiniBand 4X
4 / 2 IEC – International Electrotechnical
4/2
6Gb QSFP
Commission 6Gb QSFP
IOM3 – I/O Module 3Gbit per second
IOM6 – I/O Module 6Gbit per second
8.1
8.1
8.1.1
TERMS AND ABBREVIATIONS
FRU – Field Replacement Unit
GbE – Gibabit Ethernet
HA – High Availability
HSSDC – High-Speed Serial
Data Connector
HT – Hyper-Threading
IB4X – InfiniBand 4X
IEC – International Electrotechnical
Commission
IOM3 – I/O Module 3Gbit per second
IOM6 – I/O Module 6Gbit per second
LC – Lucent
Connector
QSFP – Quad Small Form-Factor Pluggable
NA-035-1112
LRC – Loop Resiliency Circuit
RLM – Remote LAN Module
This document
is subject to change without
notice.
Be sure toPer
cross-reference
the
LUN – Logical
Unit Number
RPM
– Revolutions
Minute
online Hardware
Universe
at http://hwu.netapp.com
MTP – Mechanical
Transfer
Pull-Offweb application
SAS
– Serial-Attached SCSI for the most
current information.
Hardware Universe SATA
is chartered
under
NEMA – National
Electrical Mfg.
– Serial
ATAthe NetApp Field Tech
Team and Pathway Enablement (FTTPE) SC
organization.
Association
– Subscriber Connector
NIC – Network Interface Card
SFP – Small Form-Factor Pluggable
NVRAM – Nonvolatile RAM
SSD – Solid State Drives
Op – Optical Connector
ST – Straight Tip Connector
PAM – Performance Acceleration Module
–TCP/IP
Offload
Engine
The Hardware Universe Poster is printedTOE
on recycled
paper.
Please
recycle after use.
PSU – Power
Supply Unit
Questions and feedback can be sent to [email protected].
7.3.5, 8.0.2, 8.1
-
NA-035-1112
Data ONTAP
Edge
Data ONTAP
Edge-T
This document is subject to change without notice. Be sure to cross-reference the
online Hardware Universe web application at http://hwu.netapp.com for the most
current information. Hardware Universe is chartered under the NetApp Field Tech
Team and Pathway Enablement (FTTPE) organization.
5TB
Capacity
V-Series
SnapVault
Secondary
SnapVault
Primary
SnapMirror
SnapShot
NFS
iSCSI
FlexVol
© 2012 NetApp, Inc. All rights reserved. Specifications are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
ONTAP-V
8.1.1
FlexCache
Operating
System
FlexClone
8.1.1
16 GbE RJ45
FAS
16 10GbE SFP+
1
1
1
1
4
3
1
1
1
2
8
6
8
2
3
3
SFP
LC
-
Op Module (4Gb) FAS/V6080,
6040, 3200, 3100, and 2050
X6588-R6
SFP+
LC
-
FAS/V6200 and FAS2240
Op Module (8Gb)
X6530-R6
SFP
SFP
0.5m
4Gb Shelf/Tape only
X6532-R6
SFP
SFP
3m
2Gb Shelf/Tape only
X6556-R6
SFP
SFP
5m
4Gb support
X6538-R6
SFP
DB9
3m
-
X6531-R6
SFP
HSSDC2
0.5m
-
X6533-R6
SFP
HSSDC2
3m
-
miniSAS
0.74 in.
(13.8 mm)
Part Number
Begin
End
Length
Notes
X6513-R6
HD-68
VHDCI
2m
-
X6557-R6
QSFP
QSFP
0.5m
-
X6558-R6
QSFP
QSFP
2m
-
X6559-R6
QSFP
QSFP
5m
-
X6590-R6
QSFP
QSFP
10m
SAS16
X6591-R6
QSFP
QSFP
20m
SAS16
X6594-R6
QSFP
QSFP
1m
SAS
X6595-R6
QSFP
QSFP
3m
SAS
X6543A-R6
QSFP
miniSAS
2m
-
X6544A-R6
QSFP
miniSAS
5m
-
SC
0.91 in.
(23 mm)
115
1
1
1
Weight
307 lb. (138 kg)
Front
30 in. (76.3 cm)
Depth
44.3 in. (112.5 cm)
Loaded Weight
1807 lb. (820 kg)
Rear
30 in. (76.3 cm)
Width
23.6 in. (60 cm)
Top
12 in. (30 cm)
Per Cabinet
PDUs
PDU Part #
Plug Type
Service
Outlet
Cords
Amps
4
X8712C-R6
(input cord tethered to PDU)
NEMA L6-30P
30A
2
48
2
NEMA
30A 3-Phase Delta
2
IEC
32A Single-Phase
4
X8713C-R6
IEC
32A 3-Phase Wye
2
X8718A-R6
IEC
60A 3-Phase Delta
2
X8721A-R6
X8719A-R6
X8720A-R6
NEMA L15-30P
Per Side
30A
(input cord tethered to PDU)
NEMA L21-30P
(input cord tethered to PDU)
Per Side
1
30A
41.5
1
41.5
IEC 60309-32A P+N+E
32A
2
64
IEC 60309-32A 3P+N+E
32A
1
96
IEC 60309-60A 3P+PE
60A
1
83.1
(input cord tethered to PDU)
(input cord tethered to PDU)
(input cord tethered to PDU)
Outlets
Approx Power
Thermal
24
10 kW @ 208V
34075
8.6 kW @ 208V
29461
Per Side
IEC 60320-C13
24
IEC 60320-C13
24
8.6 kW @ 208V
IEC 60320-C13
24
IEC 60320-C13
24
IEC 60320-C13
24
IEC 60320-C13
Length
Notes
X6558-R6
QSFP
QSFP
2m
FAS/V6200 NVRAM8 HA
X6559-R6
QSFP
QSFP
5m
FAS/V6200 NVRAM8 HA
X1956-R6
QSFP
MTP
-
Op Mod FAS/V6200 NVRAM8
X1945A-R6
MTP
MTP
5m
-
X1946A-R6
MTP
MTP
30m
-
X1951A-R6
MTP
SC
30m
4X to 1X path
X1952A-R6
MTP
ST
30m
4X to 1X path
X1953A-R6
MTP
LC
30m
4X to 1X path
X1954A-R6
MTP
FC
30m
4X to 1X path
X1955A-R6
MTP
MT-RJ
30m
4X to 1X path
X-SFP-H10GB-CU1M-R6
SFP+
SFP+
1m
FAS/V3200 HA
X-SFP-H10GB-CU3M-R6
SFP+
SFP+
3m
FAS/V3200 HA
X-SFP-H10GB-CU5M-R6
SFP+
SFP+
5m
FAS/V3200 HA
X6589-R6
SFP+
LC
-
Op Module FAS/V3200 HA
X6566-3-R6
QSFP
QSFP
3m
10Gbe
X6566-2-R6
QSFP
QSFP
2m
10Gbe
X6566-5-R6
QSFP
QSFP
5m
10Gbe
X6566-05-R6
QSFP
QSFP
0.5m
10Gbe
SFP+
+
P
0.53 in.
(13.7 mm)
0.53 in.
(13.7 mm)
0.53 in.
(13.7 mm)
FC
0.39 in.
(9.9 mm)
L21-30P
Part Number
Begin
End
Length
Notes
X6560-R6
RJ45
RJ45
0.5m
CAT6
X6561-R6
RJ45
RJ45
2m
CAT6
X6562-R6
RJ45
RJ45
5m
CAT6
X6577-R6
RJ45
RJ45
30m
CAT6
X6563-R6
SFP+
LC
-
X1107A Op Module
X6569-R6
SFP+
LC
-
X1117A Op Module
X6589-R6
SFP+
LC
-
FAS/V6200 10GbE Op Mod
X6592-R616
RJ45
RJ45
10m
CAT6 - ACP
X6593-R616
RJ45
RJ45
20m
CAT6 - ACP
X-SFP-H10GB-CU1M-R6
SFP+
SFP+
1m
Cisco Twinax
X-SFP-H10GB-CU3M-R6
SFP+
SFP+
3m
Cisco Twinax
5m
Cisco Twinax
End
Length
Notes
X6510A-R6
SC
SC
5m
OM2, 50u, 500MHz
X6511A-R6
SC
SC
30m
OM2, 50u, 500MHz
X6524-R6
2 x LC
2 x LC
2m
OM2, 50u, 500MHz
X6553-R6
LC
LC
2m
OM3, 50u, 2000MHz
X6536-R6
LC
LC
5m
OM3, 50u, 2000MHz
X6554-R6
LC
LC
15m
OM3, 50u, 2000MHz
X6537-R6
LC
LC
30m
OM3, 50u, 2000MHz
X-SFP-H10GB-CU5M-R6
X6523-R6
2 x LC
2 x SC
2m
OM2, 50u, 500MHz
X-TWX-0101-R6
SFP+
SFP+
1m
Brocade Twinax
X6547-R6
LC
SC
5m
OM3, 50u, 2000MHz
X-TWX-0301-R6
SFP+
SFP+
3m
Brocade Twinax
X6546-R6
LC
SC
30m
OM3, 50u, 2000MHz
X-TWX-0501-R6
SFP+
SFP+
5m
Brocade Twinax
DS2246
SAS
900GB
50239
22.1 kW @ 230V
75359
17.2 kW@ 208V
58991
32A
DS4486 6TB SATA (2 x 3TB)
DS424x 600GB SAS
DS424x 3TB SATA
DS424x
200GB
SSD
Interface (Gb/Sec)
Part No.
Capacity
RPM
EOA/EOS
Minimum
Data ONTAP®
X274B-R5
144GB
10K
05.2008
06.2013
6.4.5, 7.X, 8.0
X278A-R5
144GB
15K
11.2009
12.2014
6.4.5, 7.X, 8.0
X276A-R5
300GB
10K
03.2009
04.2014
7.2.1, 7.3, 8.0
X279A-R5
300GB
15K
01.2013
7.2.1, 7.3, 8.0, 8.1
X291A-R5
450GB
15K
-
7.2.5, 7.3, 8.0, 8.1
29461
14.7 kW @ 230V
DS4486 8TB SATA (2 x 4TB)
600GB
15K
-
1
QSFP – Quad Small Form-Factor Pluggable
Slot 4
RLM – Remote LAN Module
RPM – Revolutions Per Minute
SAS – Serial-Attached SCSI
SATA – Serial ATA
17.61 in. (44.7 cm)
SC – Subscriber Connector
SFP – Small Form-Factor Pluggable
SSD – Solid State Drives
ST – Straight Tip Connector
TOE –TCP/IP Offload Engine
M
P
For more information, visit:
netapp.com/techontap/community
Feedback and questions can be sent to:
[email protected]
Please refer to the Site Requirements Guide on the NetApp Support site:
support.netapp.com for typical case values.
6 Thermal dissipation values shown are based on worst-case system
values. Please refer to the Site Requirements Guide on the NOW site
for more information.
Part No.
7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on
the vertical FC boards,
all are considered as on-board ports, can be
17.6 in. (44.7 cm)
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
Operation at 1Gb speeds is not supported.
Get Involved With NetApp…
Join Tech OnTap
NetApp’s Tech OnTap program provides monthly IT insights plus
technical case studies, real-world best practices, behind the scenes
engineering interviews, exclusive invites to local user groups and
much, much more.
For more information, visit:
netapp.com/techontap/community
Feedback and questions can be sent to:
Part No.
Capacity
RPM
EOA/EOS
Minimum
Data ONTAP®
2220
encrypted
3TB
7K
-
8.1.1
11
2240 2240
2U
4U 4243 4246 2246
X310A-R5
500GB
X268A-R5
750GB
X269A-R5
1TB
X302A-R5
1TB
7.3.2, 8.0, 8.1
X294A-R5
2TB
X486A-R5
450GB
10K
-
8.1.1
X306A-R5
2TB
encrypted
600GB
15K
-
8.1
X308A-R5
3TB
encrypted
600GB
10K
X478A-R5
3TB
X422A-R5
600GB
10K
-
7.3.4, 8.0.1, 8.1
X412A-R5
600GB
15K
-
7.3.2, 8.0, 8.1
X487A-R5
600GB
10K
-
8.1.1
encrypted
600GB
10K
-
8.1.1
X423A-R5
900GB
10K
-
7.3.5, 8.0.2, 8.1
X488A-R5
900GB
10K
-
7.3.5, 8.0.2, 8.1
X870D-R6
Rail Kit
X877B-R6
Rail Kit
X8783A-R6
Blank Panel
(3rd party pass through)
X8784-R6
Bolt-Down Kit
X878-R6
Mounting Bracket Tie-Down
(6U Controllers only)
X8773-R6
Mounting Bracket Tie Down
(2020 Controllers only)
X8775-R6
Mounting Bracket Tie Down
(3200 Controllers only)
X8778-R6
Mounting Bracket Tie Down
(DS4486 only)
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1, 20 in 8.0.2 and 8.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
Cable Mgmt. / Velcro Ring
14 Requires Data ONTAP 8.1 release or higher.
1U Blank Panel
X8776B-R6
15 Flash Cache is not supported on the FAS3210 storage systems in
the Data ONTAP 8.1 release.
2U Blank Panel
X8778B-R6
Mounting kit for use with
Cisco Management switches
(pn/ X1965-R5)
X5528A-R6
10 NVMEM on select FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
result in less memory for available to Data ONTAP.
11 Encrypted drive.
12 Double stack disk tray, 2 drives per tray.
16 Minimum Data ONTAP Support - 7.3.5.1, 8.0.1P5, and 8.0.2 and later;
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS ports Storage Support - DS224x & DS424x.
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
27 in. IEC60320 C13 TO C14
IEC 60320 Plugs
X800-42U-R6
X1558A-R6
X414A-R5
3rd Party Cabinet Rail Kits
2 or 4-Post Rackmount Kit
(FAS2020 & FAS2040)
X5518A-R6
X8779-R6
4-Post Rackmount Kit
(Round Hole 4 Post Cabinet)
X5525A-R6
X893A-R6
4-Post Rackmount Kit
X5526A-R6
C14
2-Post Rackmount Kit
(DS2246)
X5527A-R6
4-Post Rackmount Kit
(Square Hole 4 Post Cabinet)
X5529A-R6
Part No.
Capacity
RPM
EOA/EOS
Minimum
Data ONTAP®
X274B-R5
144GB
10K
05.2008
06.2013
6.4.5, 7.X, 8.0
X278A-R5
144GB
15K
11.2009
12.2014
6.4.5, 7.X, 8.0
X276A-R5
300GB
X279A-R5
300GB
U10
X292A-R5
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS ports Storage Support - DS224x & DS424x.
450GB
600GB
1
Part No.
U07
15K
01.2013
LC – Lucent Connector
LRC – Loop Resiliency Circuit
LUN – Logical Unit Number
MTP – Mechanical Transfer Pull-Off
NEMA – National Electrical Mfg.
Association
NIC – Network Interface Card
NVRAM – Nonvolatile RAM
Op – Optical Connector
PAM – Performance Acceleration Module
PSU – Power Supply Unit
NA-035-1112
This document is subject to change without notice. Be sure to cross-reference the
online Hardware Universe web application at http://hwu.netapp.com for the most
Capacity
RPM
SSD – Solid State Drives
ST – Straight Tip Connector
TOE –TCP/IP Offload Engine
Get Involved With NetApp…
Join Tech OnTap
NetApp’s Tech OnTap program provides monthly IT insights plus
technical case studies, real-world best practices, behind the scenes
engineering interviews, exclusive invites to local user groups and
much, much more.
For more information, visit:
netapp.com/techontap/community
2240 2240
2220 2U
4U 4243 4246 2246
-
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000 bytes) and is derived based on the type,
300GB
15K
size, andX410A-R5
number of drives.
8.1.1
10 NVMEM on select
FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
result in less memory for available to Data ONTAP.
-
11 Encrypted
drive.
7.3.2,
X421A-R5
QSFP – Quad Small Form-Factor Pluggable
RLM – Remote LAN Module
RPM – Revolutions Per Minute
SAS – Serial-Attached SCSI
SATA – Serial ATA
SC – Subscriber Connector
SFP – Small Form-Factor Pluggable
Minimum
Data ONTAP®
450GB
10K
5 AC Power values shown are worst-case and reflect system running on
450GB
one PSU,X411A-R5
high fan speed, and power
distributed over 15K
one power cord.
Please refer to the Site Requirements Guide on the NetApp Support site:
support.netapp.com for typical case values.
11
11
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1,
20 in8.0.1,
8.0.2 and
7.3.4,
8.18.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
Capacity
RPM
X441A-R5
100GB
N/A
-
8.1.1
X442A-R5
100GB
N/A
08.2011
8.0.1
X446A-R6
200GB
N/A
-
8.1.1
6 Thermal X486A-R5
dissipation values shown450GB
are based on worst-case
10K system
values. Please refer to the Site Requirements Guide on the NOW site
for more information.
-
16 Minimum Data ONTAP Support - 7.3.5.1, 8.0.1P5, and 8.0.2 and later;
8.1 Hardware Support - X2065, X2067 (FAS6200), and FAS3200 series
on-board SAS 8.1.1
ports Storage Support - DS224x & DS424x.
600GB
7 FAS6200X414A-R5
embedded Fibre Channel
ports and Fibre Channel ports on
15K
encrypted
the vertical FC boards, all are considered
as on-board ports, can be
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
Operation at 1Gb speeds is not supported.
-
600GB
17 The DS14mk2 AT
disk shelf and disks will not be shipping in
8.1
Production starting 01/02/2013. The AT dongle that is not RoHS
2012 compliant (RoHS currently for Europe). Only spares of shelves
and spare hard drives FRUs can be shipped out in 2013.
8.1.1
X422A-R5
600GB
10K
-
7.3.4, 8.0.1, 8.1
X412A-R5
600GB
15K
-
7.3.2, 8.0, 8.1
X487A-R5
600GB
10K
-
8.1.1
encrypted
600GB
10K
-
8.1.1
900GB
10K
-
7.3.5, 8.0.2, 8.1
X423A-R5
2220
2240 2240
2U
4U 4243 4246 2246
Minimum
EOA/EOS Data ONTAP
Capacity
RPM
X262B-R5
250GB
7.2K
05.2008
06.2013
7.1.1, 7.2, 7.3,
8.0
17
X267A-R5
500GB
7.2K
08.2010
09.2015
7.1, 7.2, 7.3, 8.0,
8.1
17
X310A-R5
500GB
7.2K
08.2010
09.2015
7.3.2, 8.0, 8.1
X268A-R5
750GB
7.2K
11.2009
12.2014
7.2.1, 7.3, 8.0,
8.1
17
X269A-R5
1TB
7.2K
05.2012
06.2017
7.2.3, 7.3, 8.0,
8.1
17
X302A-R5
1TB
7.2K
-
7.3.2, 8.0, 8.1
X294A-R5
2TB
7.2K
05.2012
06.2017
7.3.2, 8.0, 8.1
X306A-R5
2TB
7.2K
-
7.3.2, 8.0, 8.1
X308A-R5
3TB
7.2K
-
8.0.2, 8.1
X478A-R5
3TB
7.2K
-
8.1.1
8TB
7.2K
-
8.1.2
®
2220
2240 2240
2U
4U 4243 4246 4486 mk2AT
Part No.
17
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
10K
8 The number of onboard SAS ports
differs based on the
configuration.
encrypted
X494A-R5
®
14 Requires Data ONTAP 8.1 release or higher.
15 Flash Cache is not supported on the FAS3210 storage systems in
7.3.2, 8.0, 8.1
the Data ONTAP 8.1 release.
9 100 LUNs from one array using one array LUN group. Combined LUN
and NetApp disk can total 240 devices.
11
8.0, 8.1
-
X416A-R5
X480A-R6
11
Minimum
EOA/EOS Data ONTAP
Part No.
12 Double stack disk tray, 2 drives per tray.
-
11
Storage Chassis
7.2.5, 7.3, 8.0, 8.1
EOA/EOS
NOTES
3TB
11
7.2.1, 7.3, 8.0, 8.1
-
15K
4 Maximum aggregate size is calculated using base 2 arithmetic
(1TB = 240 bytes).
The Hardware Universe Poster is printed on recycled paper. Please recycle after use.
Questions and feedback can be sent to [email protected].
© 2012 NetApp, Inc. All rights reserved. Specifications are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
mk4
To scan, simply open the app and hold your device’s camera up to the QR code.
Keep your hand steady and try to center the image of the QR code on your phone
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
7.3.2,
8.0,
data15K
linked to the QR-should automatically
open
up.8.1
3 Max capacity shown can only be achieved using 3TB drives under
Data ONTAP 8.0.2 or greater.
U05
U01
mk2
03.2009
7K
1 HA values shown reflect a Controller+IOXM
encrypted(CI) configuration.
X309A-R6
U06
U02
4
Storage Chassis
U08
U03
2
8.1.1
Storage Chassis
10K
8.0
Scan
the04.2014
QR Code7.2.1,
to 7.3,
learn
more about
the NetApp Hardware Universe site.
U09
Depth:
in. (61.2
17
The 24.1
DS14mk2
ATcm)
disk shelf and disks will not be shipping in
Production starting 01/02/2013. The AT dongle that is not RoHS
2012 compliant (RoHS currently for Europe). Only spares of shelves
and spare hard drives FRUs can be shipped out in 2013.
11
11
DS14 Model
First, you need to have a smartphone or tablet equipped with a camera. It also has
to have a code-reading (QR) application.
X291A-R5
(8.6 cm)
16 Minimum Data ONTAP Support - 7.3.5.1,
8.0.1P5, and 8.0.2 and later;
U04
X416A-R5
X5515A-R6
2 or 4-Post Rackmount Kit
Interface (Gb/Sec)
U14
11
C13
X494A-R5
17 The DS14mk2 AT disk shelf and disks will not be shipping in
Production starting 01/02/2013. The AT dongle that is not RoHS
2012 compliant (RoHS currently for Europe). Only spares of shelves
and spare hard drives FRUs can be shipped out in 2013.
U11
Power Distribution
48 in. IEC60320 C13 TO C14
X879B-R6
NOTES
U17
Empty Cabinet
(No PDUs/Rails)
Interconnect Kit
TERMS AND ABBREVIATIONS
[email protected]
32A (red 5-pin)
-
U12
ACP – Alternate Control Path
FRU – Field Replacement Unit
BTU – British Thermal Unit
GbE – Gibabit Ethernet
Cu – Copper Connector
HA – High Availability
EOA – End of Availability
HSSDC – High-Speed Serial
Data Connector 1.69 in.
EOS – End of Support
(4.3 cm)
HT – Hyper-Threading
ESH – Electronically Switched Hub
IB4X – InfiniBand 4X
FAS – Fabric-Attached Storage
Depth: 20 in. (50.8IEC
cm) – International Electrotechnical
FCP – Fibre Channel Protocol
Commission
17.5 in. (44.5 cm)
FC – Ferrule Connector
IOM3 – I/O Module 3Gbit per second
FC – Fibre Channel
IOM6 – I/O Module 6Gbit per second
500GB
15K
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1, 20 in 8.0.2 and 8.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
17.5 in. (44.5 cm)
X267A-R5
7.3.2, 8.0, 8.1
450GB
11 Encrypted drive.
1.69 in.
(4.3 cm)
250GB
X411A-R5
Scan the QR Code to learn more about
U26the NetApp Hardware Universe site.
U13
9 100 LUNs from one array using one array LUN group. Combined LUN
and NetApp disk can total 240 devices.
X262B-R5
7.3.4, 8.0.1, 8.1
10 NVMEM on select FAS / V Series storage controllers leverage a
portion of the storage controller available RAM memory. This will
Depth:
23.1
in. (58.7
cm) for available to Data ONTAP.
result
in less
memory
8 The number of onboard SAS ports differs based on the configuration.
Capacit
-
U15
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
200GB
10K
9 100 LUNs from one array using one array LUN group. Combined LUN
3.4 in.
and NetApp
disk can total 240 devices.
P is not supported on the FAS3210 storage systems in
15 Flash Cache
the Data ONTAP 8.1 release.
3.4 in.
60A (3-pin + PE)
System Cabinet Part Numbers
8 The number of onboard SAS ports differs based on the configuration.
14 Requires Data ONTAP 8.1 release or higher.
X446A-R6
450GB
U16
NetApp’s Tech OnTap program provides monthly
IT insights
plus size is calculated using base 2 arithmetic
4 Maximum
aggregate
= 240 bytes).
technical case studies, real-world best practices,(1TB
behind
the scenes
engineering interviews, exclusive
user
and
Minvites to local
M on
5 AC
Power
values
shown are worst-case and reflect system running
Pgroups
one PSU, high fan speed, and power distributed over one power cord.
much, much more.
100GB
X421A-R5
To scan, simply open the app and hold your device’s camera up to the QR code.
Fibre phone
Channel ports and Fibre Channel ports on
Keep your hand steady and try to center the image7ofFAS6200
the QRembedded
code on your
the vertical FC boards, all are considered as on-board ports, can be
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
data linked to the QR should automatically open up.Operation at 1Gb speeds is not supported.
12 Double stack disk tray, 2 drives per tray.
X442A-R5
7.3.2, 8.0, 8.1
First, you need to have a smartphone or tablet equipped with a camera. It also has
6 Thermal dissipation values shown are based on worst-case system
Depth: 24 in. (60.7 cm)
to have a code-reading (QR)
application.
values. Please refer to the Site Requirements Guide on the NOW site
Get Involved With NetApp…
3 Max capacity shown can only be achieved using 3TB drives under
Join Tech OnTap
Data ONTAP 8.0.2 or greater.
100GB
-
support.netapp.com for typical case values.
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000
bytes)
17.6 in.
(44.7and
cm) is derived based on the type,
size, and number of drives.
X441A-R5
15K
Scan the QR Code to learn
5 AC Powermore
values shownabout
are worst-case and reflect system running on
Slot 6
one PSU, high fan speed, and power distributed over one power cord.
the NetApp Hardware Universe
site.
U18
Please refer to the Site
Requirements Guide
on the NetApp Support site:
1 HA values shown reflect a Controller+IOXM (CI) configuration.
Capacit
300GB
U19
NOTES
Part No.
X410A-R5
4 Maximum aggregate size is calculated using base 2 arithmetic
(1TB = 240 bytes).
(8.6 cm)
mk4
U28
3 Max capacity
5.12 in.shown can only be achieved using 3TB drives under
Data ONTAP
8.0.2 or greater.
(13 cm)
P
mk2
X309A-R6
U20
M
4
U29
2 System capacity is calculated using base 10 arithmetic
(1TB=1,000,000,000,000 bytes) and is derived based on the type,
size, and number of drives.
for more information.
2
DS14 Model
Storage Chassis
L6-30P
U21
Slot 5
Slot 3
0.49 in.
(12.7 mm)
Begin
X292A-R5
1 HA values shown reflect a Controller+IOXM (CI) configuration.
Slot 2
RJ45
Optical Module
Part Number
IEC 60309 Plugs
NEMA Plugs
L15-30P
End
Clearance
Empty Weight
NEMA
30A 3-Phase Delta
Begin
DISK DRIVES
78.7 in. (200 cm)
NEMA
30A Single-Phase
Part Number
SFP+
0.39 in.
(9.8 mm)
0.36 in.
(9.1 mm)
0.53 in.
(13.7 mm)
0.49 in.
(12.5 mm)
ST
0.46 in.
(11.8 mm)
Height
Configuration
U23
Depth: 20 in. (50.8 cm)
Data ONTAP Edge
113 @100-120V
113 @100-120V
+
LRC – Loop Resiliency Circuit
LUN – Logical Unit Number
MTP – Mechanical Transfer Pull-Off
NEMA – National Electrical Mfg.
Association
NIC – Network Interface Card
4 /NVRAM
2
– Nonvolatile RAM
6Gb QSFP
Op – Optical Connector
PAM – Performance Acceleration Module
PSU – Power Supply Unit
33W @100-120V
33W @200-240V
De-Dupe
Data ONTAP®
(Min Release)
403 @100-120V
403 @200-240V
1
1
X6539-R6
LC
1
1
Op Module (2Gb)
System Cabinet Configurations
U25
Slot 1
LCRJ45
– Lucent Connector
8 / 4 GbE
X6589-R6
CIFS
Ethernet
128W @100-120V
118W @200-240V
3
-
MT-RJ
Dimensions
U35
U22
TERMS AND ABBREVIATIONS
-
10Gb SFP+
Watts
(Worst-case)
4
8.0.1, 8.1
X1970A-R5
Flash Cache - 256GB
First, you need to have a smartphone or tablet equipped with a camera. It also has
to have a code-reading (QR) application.
12GB / 6GB10
FAS/V3200
1.5GB / 768MB
NVMEM
12GB / 6GB10
(Single contoller shown)
12GB / 6GB10
© 2012 NetApp, Inc. All rights reserved. Specifications are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
CN1610
FAS2240-4
ACP – Alternate Control Path
BTU – British Thermal Unit
Cu – Copper Connector
EOA – End of Availability
EOS – End of Support
ESH – Electronically Switched Hub
FAS – Fabric-Attached Storage
FCP – Fibre Channel Protocol
FC – Ferrule Connector
FC – Fibre Channel
FAS/V3210
FAS/V3220
FAS/V3240
FAS/V3250
FAS/V3270
FAS/V6210
Model
Cluster
Management
X1956-R6
BTU/hr
(Worst-case)
Platform
Specifications
1U
8.1.2
HA
Environmental HA Pair / Single Controller
Rack Units
Cluster
CN1601
Ethernet
Supported
Modes
CN1610
Fibre
Channel
Model
1
8.0.1, 8.1
X1956-R6 (optional)
PCIe
U27
Depth: 24 in. (61 cm)
Optical Module Support for Onboard Ports
FAS/V6240
Cluster-Mode Switches
7.3.5, 8.0.1, 8.1
FAS/V6280
(Min Release)
8.0.1, 8.1
4 / 2 PCIe
4/2
4/2
ACP – Alternate Control Path
GbE RJ45
GbE RJ45
4/2
4Gb SFP
4/2
6Gb QSFP
1GB / 512MB
NVMEM
12 / 6 PCIe
4/2
GbE RJ45
4/2
4Gb SFP
10GB / 4GB10
3.2GB / 1.6GB
NVMEM
12 / 6 PCIe
4/2
GbE RJ45
4/2
4Gb SFP
24GB / 12GB10
2GB / 1GB
NVMEM
12 / 6 PCIe
4/2
GbE RJ45
8-16 / 4-8
8Gb SFP+7
16GB / 8GB10
4GB / 2GB
NVMEM
12 / 6 PCIe
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
0-24 / 0-12
6Gb QSFP8
40GB / 20GB10
4GB / 2GB
NVMEM
8 / 4 PCIe
8-32 / 4-16
8Gb SFP+7
0-24 / 0-12
6Gb QSFP8
1
8.0.1, 8.1
U30
2/1
64-bit dual-core HT
FAS2220
Ethernet
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
40GB / 20GB10
8GB / 4GB
24 / 12 PCIe
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
3
8.0.1, 8.1
-
LC
0.72 in.
(13.8 mm)
1
8
U24
(HA configuration shown)
(HA / Single)
48GB / 24GB
8GB / 4GB
24 / 12 PCIe
2
8
To scan, simply open the app and hold your device’s camera up to the QR code.
Keep your hand steady and try to center the image of the QR code on your phone
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
data linked to the QR should automatically open up.
CN1601
Exp Slots
6
7.3, 8.0, 8.1
Cu - QSFP
SFP
U32
1806 / 1471 @100V
1751 / 1444 @200V
FAS2240-2
8GB / 4GB
(HA / Single)
(HA / Single)
96GB / 48GB
Snap Restore
Platform Specifications
HA Pair / Single Controller
NVRAM
6
8.1
U33
Slot 16
M
CN1610
(HA / Single)
4
1013
-
U34
Slot 15
Slot 10
(HA configuration shown)
192GB / 96GB
1013
Cu - 68p
VHDCI
U36
+ +
17.7 in. (44.9 cm)
Memory
2
614
U37
No V-Series Models
6U / 3U
18.6A / 9.3A @100V
9A / 4.5A @200V
Q
17.53 in. (44.52 cm)
Refer to the NetApp Interoperability Matrix at
http://support.netapp.com/matrix for the
latest back-end storage array support information.
6U / 3U
4/2
64-bit six-core
6
SFP+
Depth: 29 in. (73.66 cm)
Fujitsu
· DX8000
· DX4x0
· DX8700 S2
· DX4x0 S2
6U / 3U
Processor
2
4
X1140A-R6
Unified Target 2-Port 10Gb
X6529-R6
U31
6U / 6U
(HA / Single)
6
813
U38
No V-Series Models
9
12U / 6U
6486 / 3243 @100V
6212 / 3106 @200V
6
Notes
QSFP
2
813
U39
Slot 4
Q
60
(12 Int + 48 Ext)
12U / 6U
19.2A / 9.6A @100V
9.4A / 4.7A @200V
6
6
U40
- / - / 374TB
- / - / 60TB
16TB / 50TB / 50TB
600
HP
· EVA x400, x100
· P6x00, P6x50
· XP24K, XP20K
- / - / 432TB
16TB / 50TB / 75TB
720
AC Power5
4
13
Length
SAS
16TB / 70TB / 70TB
25 / 50 / 50 / 72
16TB / 50TB /
90TB
- / - / 105TB
960
Weight
8
6
End
2
8.0.1, 8.1
U41
[email protected]
240TB / 720TB3
/ 720TB3
1200
(HA / Single)
8
13
4
Begin
SSD
30 / 60 / 60 / 84
16TB / 70TB /
105TB
- / - / 1440TB3
1440
Height
813
6
X6569-R6
(FTLX8571D3BCV-IT)
U42
FAS2220
Slot 12
- / 70TB / 70TB
600TB / 1800TB3
/ 1800TB3
- / - / 2160TB3
1440
(HA / Single)
813
6
4
1213
Part Number
DS14mk4 FC 600GB FC
For more information, visit:
Gigabit Ethernet
RJ45
Slot 1
960TB / 2880TB3
/ 2880TB3
- / 70TB / 162TB
- / 100TB / 100TB
EMC
· VNX
· CX3,CX4
· VMAX
· DMX4
1
Op - LC
PCIe
Depth: 9.9 in. (25.1 cm)
Slot 3
Max Drive Quantity
V-Series
Supported
Arrays
1213
1.25 in.
(31.8 mm)
0.53 in.
(13.8 mm)
2
1
0.72 in.
(13.8 mm)
MTP
SATA
FAS/V3270
- / 3600TB3 /
3600TB3
- / 100TB / 162TB
30 / 60 / 60 / 84
6
0.53 in.
(13.7 mm)
DB9
FIBRE CHANNEL
This document is subject to change without notice. Be sure to cross-reference the
online Hardware Universe web application at http://hwu.netapp.com for the most
1
current information. Hardware
Universe1is chartered FAS/V3220
under the NetApp
Field Tech
FAS/V3210
FAS/V3250
FAS/V3240
Team and Pathway Enablement (FTTPE) organization.
Expansion Slot
PCIe
Slot 11
(DS4486 / DS2246 /
DS4243 / DS14)
3
6
2
0.53 in.
(13.7 mm)
SYSTEM CABINET AND POWER
NetApp’s Tech OnTap program provides monthly IT insights plus
technical case studies, real-world best practices, behind the scenes
engineering interviews, exclusive invites to local user groups and
much, much more.
FAS/V6200
Max Shelves
4
6
HSSDC2
8 The number of onboard SAS ports differs based on the configuration.
(Single controller show)
(7.3.x / 8.0.x / 8.1.x)
12
6
7.3.2, 8.0, 8.1
FIBRE CHANNEL
FAS/V6210
- / 4320TB3 /
4320TB3
- / 100TB / 100TB
4
X1117A-R6
NIC 2-Port 10GbE
PCIe
* Cables are not supported on the FAS2040 on-board SAS port
nor the X2062 miniSAS dual-port SAS HBA for the FAS2050.
7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on
the vertical FC boards, all are considered as on-board ports, can be
set as target or initiators and support operation at 2, 4, or 8Gb speeds.
Operation at 1Gb speeds is not supported.
FAS2240-4
Max FlexVol Size
121
PCIe
15 Flash Cache is not supported on the FAS3210 storage systems in
the Data ONTAP 8.1 release.
17.6values
in. (44.7
cm) are based on worst-case system
6 Thermal dissipation
shown
values. Please refer to the Site Requirements Guide on the NOW site
for more information.
(HA configuration show)
(7.3.x / 8.0.x / 8.1.x)
3
8.0.1, 8.1
8.1
PCIe
13 Maximum number of Ethernet ports on all network adapter cards is
18 in 8.0.1, 20 in 8.0.2 and 8.1, and 32 in 8.1.x. The maximum number
shown for each adapter is for the latest ONTAP release.
The Hardware Universe Poster is printed on recycled paper. Please recycle after use.
Questions and feedback can be sent to [email protected].
- / 100TB / 162TB
12
X6588-R6
(AFBR-57D7APZ or FTLF8528P2BNV)
12 Double stack disk tray, 2 drives per tray.
Front View
Max Aggregate4
2
11 Encrypted drive.
P
NVRAM8 adapter is placed in slot 2 in a FAS6200 series controller (as shown). FAS6210 model does not support IOXM.
(7.3.x / 8.0.x / 8.1.x)
6
8
SAS
FAS/V6240
- / 4320TB3 /
4320TB3
6
8
Get Involved With NetApp…
Join Tech OnTap
Fabric-Attached NA-035-1112
Storage (FAS) and V-Series Controllers
Max Capacity2
2
7.3, 8.0, 8.1
121
8.1.1
STORAGE CONTROLLERS
FAS/V6280
4
6
0.53 in.
(13.7 mm)
17.31 in. (43.97 cm)
© 2012 NetApp, Inc. All rights reserved. Specifications are subject to change without
notice. NetApp, the NetApp logo, Go further, faster, Data ONTAP, SnapMirror and
MetroCluster are trademarks or registered trademarks of NetApp, Inc. in the United
States and/or other countries. All other brands or products are trademarks or
registered trademarks of their respective holders and should be treated as such.
Model
12
6
Op - LC
Mezzanine
P
4 Maximum aggregate size is calculated using base 2 arithmetic
(1TB = 240 bytes).
QSFP – Quad Small Form-Factor Pluggable
RLM – Remote LAN Module
RPM – Revolutions Per Minute
SAS – Serial-Attached SCSI
SATA – Serial ATA
SC – Subscriber Connector
SFP – Small Form-Factor Pluggable
4
2
PCIe
PCIe
To scan, simply open the app and hold your device’s camera up to the QR code.
Keep your hand steady and try to center the image of the QR code on your phone
or tablet screen. Once the camera locks onto the QR, the Web page, video or other
data linked to the QR should automatically open up.
3 Max capacity shown can only be achieved using 3TB drives under
Data ONTAP 8.0.2 or greater.
LC – Lucent Connector
LRC – Loop Resiliency Circuit
LUN – Logical Unit Number
MTP – Mechanical Transfer Pull-Off
NEMA – National Electrical Mfg.
Association
NIC – Network Interface Card
NVRAM – Nonvolatile RAM
Op – Optical Connector
PAM – Performance Acceleration Module
PSU – Power Supply Unit
12
7.3, 8.0, 8.1
6
6
Fixed Optics
Non-removable
PCIe
Depth: 19.1 in. (48.4 cm)
FibreBridge
6500N
FRU – Field Replacement Unit
GbE – Gibabit Ethernet
HA – High Availability
HSSDC – High-Speed Serial
Data Connector
HT – Hyper-Threading
IB4X – InfiniBand 4X
IEC – International Electrotechnical
Commission
IOM3 – I/O Module 3Gbit per second
IOM6 – I/O Module 6Gbit per second
6
6
X2053A-R6
TAPE 2-Port 4Gb
17.7 in. (45 cm)
P
SFP module pre-installed (FTLF8528P2BCV-QL)
No optical FRU available
7.3, 8.0, 8.1
6280 6240 6210 3270 3240 3210 2240
SFP module pre-installed (FTLF8528P3BCV-QL)
No optical FRU available
Depth: 24 in. (61 cm)
P
7.3.2, 8.0, 8.1
Op - LC
7.3, 8.0, 8.1
®
Op - LC
Mezzanine
P
X1131A-R6
FCP TARGET 2-Port 8Gb
Min Data ONTAP
P
-
Supported
ACP – Alternate Control Path
BTU – British Thermal Unit
Cu – Copper Connector
EOA – End of Availability
EOS – End of Support
ESH – Electronically Switched Hub
FAS – Fabric-Attached Storage
FCP – Fibre Channel Protocol
FC – Ferrule Connector
FC – Fibre Channel
X1130A-R6
FCP TARGET 4-Port 4Gb
First, you need to have a smartphone or tablet equipped with a camera. It also has
to have a code-reading (QR) application.
-
7.0, 7.1, 7.2, 7.3, 8.0, 8.1
PCIe
PCIe
7 in.
(17.8 cm)
17.6 in. (44.7 cm)
7.2.1, 7.3, 8.0, 8.1
Op - LC
PCIe
TERMS AND ABBREVIATIONS
NETAPP
HARDWARE
UNIVERSE
P
DS2246-21.6TB-QS-R5 (900GB)
ESH4
X5512A-R5
Minimum
Data ONTAP® Release
X1128A-R6
FCP TARGET 2-Port 4Gb
-
X567A-R6
X518A-R6
DS4243-SL02-24A-QS-R5 (100GB)
DS4243-1507-24S-QS-R5 (300GB)
DS4243-1511-24S-QS-R5 (450GB)
DS4243-1514-24S-QS-R5 (600GB)
DS4243-0724-24A-QS-R5 (1.0TB)
DS4243-0748-24A-QS-R5 (2.0TB)
DS4243-0772-24A-QS-R5 (3.0TB)
DSX-14.0TB-QS-R5 (1.0TB)
DSX-28.0TB-QS-R5 (2.0TB)
X559A-R6
X558A-R5
DS4243-1504-12S-QS-R5 (300GB)
DS4243-1505-12S-QS-R5 (450GB)
DS4243-1507-12S-QS-R5 (600GB)
DS4243-0712-12A-QS-R5 (1.0TB)
DS4243-0724-12A-QS-R5 (2.0TB)
DS4243-0736-12A-QS-R5 (3.0TB)
X54015A-ESH4-QS-R5 (450GB)
X64015A-ESH4-QS-R5 (600GB)
342 @100V
342 @200V
3.0TB SATA 2,970
(mixed SSD
+ SATA support)
X558A-R6
X511A-R5
P
1.0A @100V
0.5A @200V
3.0TB SATA 8.71A
EHTERNET
X511A-R5
ESH2
X5511A-R5
Disk Shelf Modules
3.30A
X562-R5
Quickship
Half Populated
Quickship
Fully Populated
900GB SAS
8.75 lb. (3.97 kg)
SCSI / SAS
AC Power
Supply
1.96A
150 lb. (68 kg)
82 lb. (33 kg)
PCIe
HA
X554A-R5
100GB SSD
X556A-R6 (2x PSU)
X557A-R6 (4x PSU)
X561-R5
56 lb. (25.4 kg)
34.6 lb. (15.7 kg)
OTHER
X553A-R5
Empty Shelf
(without PSU)
Disk Shelf Part Numbers
750GB SATA 924
1.0TB SATA 853
2.0TB SATA 849
300GB 15K FC 1,512
450GB 15K FC 1,512
600GB 15K FC 1,166
Empty Shelf
(with AC PSU)
2013
750GB SATA 2.72A
1.0TB SATA 2.51A
2.0TB SATA 2.50A
300GB 15K FC 4.43A
450GB 15K FC 4.43A
600GB 15K FC 3.44A
110 lb. (49.9 kg)
53.7 lb. (24.4 kg)
DS4243/DS4246
BTU/hr
6
110 lb. (49.9 kg)
53.7 lb. (24.4 kg)
DS4486
Environmental Specificaitons
AC Power
5
77 lb. (35 kg)
50.06 lb. (23 kg)
DS2246
77 lb. (35 kg)
50.06 lb. (23 kg)
Weight
(Empty / Loaded)
Media
Fixed Optics
Non-removable
PCIe
1U
Part Number / Description
SATA
14
Maximum Drive Quantity
Card Type
QSFP
SSD
FibreBridge
6500N
DS4486
Optical Module
DS14mk2 AT 2TB SATA17
DS2246
Fibre Channel Cable and Connectors
DS4246
SCSI \ SAS Cables and Connectors
DS4243
Optical Cables and Connectors
DS14mk2 AT
FIBRE CHANNEL
DS14mk4 FC
DS14mk4 FC
Model
Optical Module FRU
(Mfr Part Number)
SFP/SFP+
SFP/SFP+
Fabric-Attached Storage & V-Series
HA Pair, Cluster Interconnect Cables and Connectors
NetApp Disk Shelves
Ethernet Cables and Connectors
SHELF ENCLOSURES
11
11
11
X480A-R6
11
(2x4TB)
12
8TB
(2x4TB)

Similar documents