Industrial Diesel Generator Set 30 kW Diesel SD030 EPA Emissions Certification: Tier 4i 1 of 5 Standby Power Rating 37.5kVA 30kW 60 Hz Prime Power Rating* 30kVA 24KW 60 Hz Generator image used for illustration purposes only *EPA Certified Prime ratings are not available in the U.S. or its Territories for engine model year 2011 and beyond features benefits Generator Set = PROTOTYPE & TORSIONALLY TESTED 4 PROVIDES A PROVEN UNIT = UL2200 TESTED 4 ENSURES A QUALITY PRODUCT = RHINOCOAT PAINT SYSTEM 4 IMPROVES RESISTANCE TO ELEMENTS = WIDE RANGE OF ENCLOSURES AND TANKS 4 PROVIDES A SINGLE SOURCE SOLUTION = EPA COMPLIANT 4 ENVIRONMENTALLY FRIENDLY = INDUSTRIAL TESTED, GENERAC APPROVED 4 ENSURES INDUSTRIAL STANDARDS = POWER-MATCHED OUTPUT 4 ENGINEERED FOR PERFORMANCE = INDUSTRIAL GRADE 4 IMPROVES LONGEVITY AND RELIABILITY = TWO-THIRDS PITCH 4 ELIMINATES HARMFUL 3RD HARMONIC = LAYER WOUND ROTOR & STATOR 4 IMPROVES COOLING = CLASS H MATERIALS 4 HEAT TOLERANT DESIGN = DIGITAL 3-PHASE VOLTAGE CONTROL 4 FAST AND ACCURATE RESPONSE = ENCAPSULATED BOARD W/ SEALED HARNESS 4 EASY, AFFORDABLE REPLACEMENT = 4-20mA VOLTAGE-TO-CURRENT SENSORS 4 NOISE RESISTANT 24/7 MONITORING = SURFACE-MOUNT TECHNOLOGY 4 PROVIDES VIBRATION RESISTANCE = ADVANCED DIAGNOSTICS & COMMUNICATIONS 4 HARDENED RELIABILITY Engine Alternator Controls primary codes and standards 30 kW Diesel 2 of 5 SD030 application and engineering data ENGINE SPECIFICATIONS General Make EPA Emissions Compliance EPA Emissions Reference Cylinder # Type Displacement - L (cu. in.) Bore - mm (in.) Stroke - mm (in.) Compression Ratio Intake Air Method Cylinder Head Type Piston Type Engine Governing Governor Frequency Regulation (Steady State) Lubrication System Oil Pump Type Oil Filter Type Crankcase Capacity - L (qts) Generac Tier 4 Interim See Emissions Data Sheet 4 In-Line 2.4 90 (3.54) 94 (3.70) 21.3:1 Turbocharged Cast Iron Aluminum Electronic Isochronous ± 0.25% Gear Full Flow 6.2 (6.52) Cooling System Cooling System Type Water Pump Flow Fan Type Fan Speed (rpm) Fan Diameter mm (in.) Coolant Heater Wattage Coolant Heater Standard Voltage Closed Recovery Pre-Lubed, Self Sealing Pusher 2698 560 (22) 1500 120VAC Fuel System Fuel Type* Fuel Specifications Fuel Filtering (microns) Fuel Inject Pump Make Fuel Pump Type Injector Type Fuel Supply Line - mm (in.) Fuel Return Line - mm (in.) Ultra Low Sulfur Diesel Fuel ASTM 5 Bosch Engine Driven Gear Mechanical 7.94 (0.31) 7.94 (0.31) Engine Electrical System System Voltage Battery Charging Alternator Battery Size (at 0ºC) Battery Group Battery Voltage Ground Polarity 12VDC Std 925 27F/31 12VDC Negative Voltage Regulator Type Number of Sensed Phases Regulation Accuracy (Steady State) Digital All ± 0.25% ALTERNATOR SPECIFICATIONS Standard Model Poles Field Type Insulation Class - Rotor Insulation Class - Stator Total Harmonic Distortion Telephone Interference Factor (TIF) Standard Excitation Bearings Coupling Load Capacity - Standby Prototype Short Circuit Test 390 4 Revolving H H < 3.5% < 50 Synchronous Brushless Single Sealed Cartridge Direct, Flexible Disc 100% Yes CODES AND STANDARDS COMPLIANCE (WHERE APPLICABLE) NFPA 99 NFPA 110 ISO 8528-5 ISO 1708A.5 ISO 3046 BS5514 SAE J1349 DIN6271 IEEE C62.41 TESTING NEMA ICS 1 Rating Definitions: Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) Prime – Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. (Max. load factor = 80%) A 10% overload capacity is available for 1 out of every 12 hours. operating data (60Hz) POWER RATINGS (kW) STANDBY PRIME Single-Phase 120/240VAC @1.0pf 30 kW Amps: 125 24 kW Amps: 100 Three-Phase 120/208VAC @0.8pf 30 kW Amps: 104 24 kW Amps: 83 Three-Phase 120/240VAC @0.8pf 30 kW Amps: 90 24 kW Amps: 72 Three-Phase 277/480VAC @0.8pf 30 kW Amps: 45 24 kW Amps: 36 Three-Phase 346/600VAC @0.8pf 30 kW Amps: 36 24 kW Amps: 29 3 of 5 STARTING CAPABILITIES (sKVA) sKVA vs. Voltage Dip 480VAC 208/240VAC Alternator kW 10% 15% 20% 25% 30% 35% 10% 15% 20% 25% 30% 35% Standard 35 24 36 48 60 72 84 18 27 36 45 54 63 Upsize 1 40 27 41 54 68 81 95 20 31 41 51 61 71 Upsize 2 50 34 52 69 86 103 120 26 39 52 65 77 90 FUEL Fuel Consumption Rates* STANDBY PRIME Fuel Pump Lift - in (m) Percent Load gph lph Percent Load gph lph 36 (.9) 25% 0.92 3.5 25% 0.78 3.0 50% 1.45 5.5 50% 1.04 3.9 Total Fuel Pump Flow (Combustion + Return) 75% 1.96 7.4 75% 1.62 6.1 4.5 gph 100% 2.74 10.4 100% 2.4 9.1 * Refer to "Emissions Data Sheet" for maximum fuel flow for EPA and SCAQMD permitting purposes. COOLING Coolant Flow per Minute gpm (lpm) Heat Rejection to Coolant Inlet Air BTU/hr cfm (m3/hr) Max. Operating Radiator Air Temp Fº (Cº) Max. Operating Ambient Temperature STANDBY PRIME 10 (38) 10 (38) 111,000 99,000 4,500 (7647) 4,500 (7647) 122 (50) 122 (50) Fº (Cº) 104 (40) 104 (40) Coolant System Capacity gal (L) 2.8 (10.95) 2.8 (10.95) Maximum Radiator Backpressure in H2O 1.5 1.5 COMBUSTION AIR REQUIREMENTS Flow at Rated Power cfm (m3/min) STANDBY PRIME 90 (2.55) 90 (2.55) ENGINE Rated Engine Speed Horsepower at Rated kW** Piston Speed BMEP EXHAUST rpm hp ft/min (m/min) psi STANDBY PRIME 1800 1800 Exhaust Flow (Rated Output) 51 51 1110 (338) 1110 (338) Exhaust Temp (Rated Output) 153 123 Exhaust Outlet Size (Open Set) Max. Backpressure (Post Silencer) cfm (m3/min) 30 kW Diesel SD030 STANDBY PRIME 230 (391) 217 (368) inHg (Kpa) 1.5 (5.1) 1.5 (5.1) ºF (ºC) 850 (454) 775 (413) NPT (male) 63.5 (2.5) 63.5 (2.5) ** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes. Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards. 30 kW Diesel 4 of 5 SD030 standard features and options GENERATOR SET Genset Vibration Isolation IBC Seismic Certified/Seismic Rated Vibration Isolators Extended warranty Gen-Link Communications Software Steel Enclosure Aluminum Enclosure CONTROL SYSTEM Std Opt Opt Opt Opt Opt ENGINE SYSTEM General Oil Drain Extension Oil Make-Up System Oil Heater Air cleaner Fan guard Radiator duct adapter Std Opt Opt Std Std Std Fuel System Fuel lockoff solenoid Std Secondary fuel filter Stainless steel flexible exhaust connection Industrial Exhaust Silencer Critical Exhaust Silencer Flexible fuel lines Primary fuel filter Single Wall Tank (Export Only) UL 142 Fuel Tank Std Std Std Opt Opt Opt Opt Cooling System 120VAC Coolant Heater 208VAC Coolant Heater 240VAC Coolant Heater Other Coolant Heater_______________________ Closed Coolant Recovery System UV/Ozone resistant hoses Factory-Installed Radiator Radiator Drain Extension Opt Opt Opt Std Std Std Std Engine Electrical System Battery charging alternator Battery cables Battery tray Battery box Battery heater Solenoid activated starter motor 2.5A UL battery charger 10A UL float/equalize battery charger Rubber-booted engine electrical connections Std Std Std Opt Opt Std Opt Opt Std ALTERNATOR SYSTEM UL2200 GENprotectTM Main Line Circuit Breaker 2nd Circuit Breaker 3rd Circuit Breaker Alternator Upsizing Anti-Condensation Heater Tropical coating Permanent Magnet Generator Std Opt Opt Opt Opt Opt Opt Control Panel Digital H Control Panel - Dual 4x20 Display Digital G-100 Control Panel - Touchscreen Digital G-200 Paralleling Control Panel - Touchscreen Programmable Crank Limiter 21-Light Remote Annunciator Remote Relay Panel (8 or 16) 7-Day Programmable Exerciser Special Applications Programmable PLC RS-232 RS-485 All-Phase Sensing DVR Full System Status Utility Monitoring (Req. H-Transfer Switch) 2-Wire Start Compatible Power Output (kW) Power Factor Reactive Power All phase AC Voltage All phase Currents Oil Pressure Coolant Temperature Coolant Level Oil Temperature Fuel Pressure Engine Speed Battery Voltage Frequency Date/Time Fault History (Event Log) Low-Speed Exercise Isochronous Governor Control -40deg C - 70deg C Operation Waterproof Plug-In Connectors Audible Alarms and Shutdowns Not in Auto (Flashing Light) Auto/Off/Manual Switch E-Stop (Red Mushroom-Type) Remote E-Stop (Break Glass-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Flush Mount) NFPA 110 Level I and II (Programmable) Remote Communication - RS232 Remote Communication - Modem Remote Communication - Ethernet 10A Run Relay Std na na Std Opt Opt Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Opt Std Std Std Std Std Std Std Std Std Std Std Std Opt Opt Opt Std Std Opt Opt Opt Alarms (Programmable Tolerances, Pre-Alarms and Shutdowns) Low Fuel Oil Pressure (Pre-programmed Low Pressure Shutdown) Coolant Temperature (Pre-programmed High Temp Shutdown) Coolant Level (Pre-programmed Low Level Shutdown) Oil Temperature Engine Speed (Pre-programmed Overspeed Shutdown) Voltage (Pre-programmed Overvoltage Shutdown) Battery Voltage Opt Std Std Std Opt Std Std Std dimensions, weights and sound levels OPEN SET H L W USABLE CAPACITY (GAL) L W NO TANK - 76 38 46 2060 20 54 76 38 59 2540 48 132 76 38 71 2770 RUN TIME HOURS H WT 77 211 76 38 83 2979 109 300 93 38 87 3042 L W H WT dBA* 5 of 5 82 STANDARD ENCLOSURE RUN TIME HOURS H L W USABLE CAPACITY (GAL) NO TANK - 95 38 50 2362 20 54 95 38 63 2842 48 132 95 38 75 3072 77 211 95 38 87 3281 109 300 95 38 91 3344 dBA* 77 LEVEL 1 ACOUSTIC ENCLOSURE H L W RUN TIME HOURS USABLE CAPACITY (GAL) L W H WT NO TANK - 113 38 50 2515 20 54 113 38 63 2995 48 132 113 38 75 3225 77 211 113 38 87 3434 109 300 113 38 91 3497 dBA* 70 LEVEL 2 ACOUSTIC ENCLOSURE H L W USABLE CAPACITY (GAL) L W H WT NO TANK - 95 38 62 2520 20 54 95 38 75 3000 48 132 95 38 87 3230 77 211 95 38 99 3439 109 300 95 38 103 3502 dBA* 68 *All measurements are approximate and for estimation purposes only. Weights are without fuel in tank. Sound levels measured at 23ft (7m) and does not account for ambient site conditions. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER Tank Options MDEQ OPT Florida DERM/DEP OPT Chicago Fire Code OPT IFC Certification CALL ULC CALL RUN TIME HOURS 30 kW Diesel SD030 Other Custom Options Available from your Generac Industrial Power Dealer Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0185830SBY-F / Printed in U.S.A. 02/15/12
Similar documents
350 kW
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) Prime – Applicable for supplying power to a varyin...
More information250 kW - Generac
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) Prime – Applicable for supplying power to a varyin...
More informationSD230 - Generac
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) Prime – Applicable for supplying power to a varyin...
More information