Brochure - Hackney Emergency Vehicles

Transcription

Brochure - Hackney Emergency Vehicles
LIGHT RESCUE
SEE IT AT THE FDIC – INDIANAPOLIS APRIL 21-23
2016 FORD F550 HACKNEY LR0764 RESCUE DEMONSTRATOR
Representative Photo Only
Features (see specifications for full details):
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
300 hp V-8 PowerStroke diesel engine
19,500 lb. GVWR (not less than 5000 lb. payload)
Four-wheel drive
Aluminum alloy wheels with stainless steel hub
and lug covers
XLT trim level – chrome grille, power windows
and locks, adjustable foot pedals, keyless entry,
Ford Sync
Cab entry step bars
Telescoping mirrors
40-gallon fuel tank
12’ 8” Rescue Body with all roll-up painted doors
364 cu.ft. storage capacity (calculated using door
pass-thru dimensions
10,000# winch receivers on side and rear body
Cribbing and chock block ventilated storage
Transverse slide-out SCBA and toolboard
Stokes & Backboard storage tunnels
Rear extrication tool compartment with prewiring for hydraulic reels
•
•
•
•
•
•
•
•
•
•
•
Folding ladder storage tunnel
Tilt-out fire extinguisher storage (B:C and
water)
Whelen LED light bar and M-series LED warning
lights
Whelen LED tail lights
Whelen M9 scene lights (6)
LED ground lights
LED compartment light strips recessed in walls
6kw hydraulic generator
Knight Light tower with (6) Whelen PFP2 LED
flood lights
Hannay cord reel with 200-ft yellow 10/3 cable
Kussmaul 20-amp AutoEject shorepower with
30-amp automatic transfer relay
Available for purchase off
090512-VTH
Hackney Emergency Vehicles 1-800-763-0700 | 1-252-946-6521 | www.hackneyev.com | [email protected]
Final Shop Order
VT Hackney
911 West 5th St.
Washington, NC 27889
VT Hackney
911 West 5th St.
Washington, NC 27889
Sales Rep:
Keith Bousquet - Sales Engineer
Jim Kuhlman - Body Engineer
Terms:
NA
Drawing #:
Est. Delivery Date:
Customer PO #:
Customer #:
QPF #:
11/21/2015
E3178-0002
16F20050
LR100
Exp. Date:
Quote No:
Job/Order No:
BODY:
10/28/2015
PART NO
S
00-00-0000
02-10-1000
02-10-1100
05-00-0000
10-04-5255
h15c987
/ /
NA
NA
NA
S
Penalty:
NA
LIGHT RESCUE - revised 05/15
DESCRIPTION
== LIGHT RESCUE - revised 05/15 - 1.001 ==
=== QW Release - Effective 10/01/15
OAH Restriction - None
OAL Restriction - None
INTENT OF SPECIFICATIONS
CAB AND CHASSIS
< > FORD F-550 - 4-DR/4WD - 84"CA
Chassis Supplier: Pecheles Ford
Est. Arrival Date:
Wheelbase: 200.2"
Chassis CA: 84"
XLT trim level
Prep Package: 47A Emergency Vehicle
Engine: 6.7L Power Stroke 300hp @ 2800rpm; 660lb-ft @ 1600rpm Turbo Diesel
with aux. idle control
Transmission: Heavy-duty TorqShift 6-speed SelectShift automatic with PTO port
Transfer Case: New Venture 273 with electronic shift (rotary control)
Front Axle: 7000# Dana Super 60; driver type
Rear Axle: 14,706# Dana S130 with limited slip differential
Rear Axle Ratio: 4.88
Aluminum alloy wheels
Tires: 225/70R19.5 Traction-BSW
Driver/Passenger Seats: Individual high back vinyl with shoulder harness and lap
belts - Driver power adjustable
Rear Crew Seat: Three-man bench with shoulder harness and lap belts
Alternator (factory installed): Dual 160-amp
Air Conditioner
Chrome Package
Power windows and door locks
Ford black steel step bars
Ext. Color: White
Int. Color: Dark Gray
QTY
1
1
1
1
1
1
1
Page 1
ID
HS
HS
HS
HS
HS
HS
HS
10/28/2015
PART NO
S
10-19-0000
DESCRIPTION
CHASSIS RELATED OPTIONS
< > FLUID LEVEL DATA PLATE - VISIONMUX
-- sub-surface screen printed polycarbonate label
-- Hackney P/N #805128
Page 2
QTY
ID
1 HS
1 HS
10-19-1025
< > "MUST BE SEATED AND BELTED" - WARNING PLATE
-- "Must be seated and belted" according to NFPA 1901, section 14.1.3.5 (P/N
805129)
-- sub-surface screen printed polycarbonate label with chrome bezel
-- On cab dash visible to driver and crew
1 HS
10-19-1045
<
WARNING PLATE - VEHICLE SPECIFICATION DATA
It shall have a verbal warning indication for the following vehicle specification data
in compliance with NFPA 1901-2009, section 12.1.5.1 and section 14.1.2 :
1 HS
- Vehicle Height
- Vehicle Length
- Gross Vehicle Weight Rating (GVWR)
- Vehicle Occupancy Maximum
Location: cab dash visible to driver and crew
10-19-1075
<
"DO NOT WEAR HELMET WHILE SEATED" - WARNING PLATE
-- installed visible to each seating position
-- warning label to indicate "DO NOT WEAR HELMET WHILED SEATED"
-- required in compliance with NFPA 1901-2009, Section 14.1.8.4.3
1 HS
10-99-2510
<
EXHAUST PIPE EXTENSION - FORD SUPER-DUTY
- required to extend tailpipe from inside of frame rail to outer edge of body on
cab/chassis equipped with 2007 and later emissions engines
- Hackney P/N #816264
- sub-surface screen printed polycarbonate label with chrome bezel that reads
"WARNING - Stand clear of exhaust. Temperature may rise at any time." installed
adjacent to the exhaust exit point (Hackney P/N #816266)
1 HS
WARNING PLATE: -- Sub-surface screen printed polycarbonate label with
chrome bezel that reads "WARNING - Stand cler of exhaust. Temperatur may rise
at any time." (Hackney P/N 816266)
Location: Adjacent to the exhaust exit point
11-16-0200
<
BATTERY CONDITIONER - PROGRESSIVE DYNAMICS 45-AMP
335908
-- PD9245C Conditioner with built-in Charge Wizard
-- 45 amp - Single battery system - will charge up to (3) batteries and hand-lights
simultaneously
-- Input - 120v
Weight: 4.5 lbs.
1 HS
Conditioner Location: Centered under ladder tunnel on forward wall in S-1, C-1
bays
11-17-2000
S
<
SHOREPOWER- KUSSMAUL AUTO-EJECT - 20 AMP
-- Hackney P/N #806287
-- Super Model - sealed weatherproof box
-- Model #091-55-20-120-BW
-- NEMA 5-20C connector shipped loose
-- Includes shorepower data label - Hackney P/N #813380
1 HS
Location of Inlet: Streetside wheelhousing skirt area, forward of the rear wheels
*** NOTE TO ENGINEERING/SHOP: Fan in C-3 cribbing compartment to be
connected to shoreline plug. ***
11-17-2015
<
COVER - 20-AMP SUPER AUTO-EJECT - RED
-- Kussmaul p/n #091-55RD
1 HS
10/28/2015
PART NO
S
DESCRIPTION
QTY
Page 3
ID
-- Color: Red
11-31-5000
<
ENGINE COMP'T LIGHT W/SWITCH - 5" (EA)
-- NFPA 1901 Requirement
2 HS
Location: one (1) streetside (left) and curbside (right) of the engine
11-32-SP01
X
11-33-0802
< > DOME LIGHTING - CAB - RED/CLEAR - LUMITEC (EA)
-- Lumitec model # 101139 (Chrome)
Location: Centered in cab above cab console
<
GROUND LIGHTS - TECNIQ LED - FRONT CAB DOOR (PR)
-- E10-WS00-1 LED ground light with stainless steel angled bracket
-- 0.35-amps each
-- 6.5" x 3.3"
-- 675 lumens each
-- Angled stainless steel bracket with a light beam angle of approximately 120
degrees x 50 degrees
1
1 HS
Location: beneath left and right cab doors
Activated in the following scenarios:
1. Left and right cab doors are open
2. Respective body side scene lights are activated
11-33-0804
<
GROUND LIGHTS - TECNIQ LED - REAR CAB DOOR (PR)
-- E10-WS00-1 LED ground light with stainless steel angled bracket
-- 0.35-amps each
-- 6.5" x 3.3"
-- 675 lumens each
-- Angled stainless steel bracket with a light beam angle of approximately 120
degrees x 50 degrees
1 HS
Location: beneath left and right cab doors
Activated in the following scenarios:
1. Left and right cab doors are open
2. Respective body side scene lights are activated
12-00-1000
12-57-0021
15-50-9001
<
S
<
MUD FLAPS, FRT (PR) BLACK RUBBER
TIRE PRESSURE MONITORING - REALWHEELS AIRSECURE - 6-WHL
Sensor activates LED when pressure drops 5-8 psi
1 HS
1 HS
RECEIVER - RECCESSED SIDE BODY - LR (PR)
-- 2" Class III/IV receiver
-- extends outward of panel surface to allow pinning of rope tie-off rings or
portable winch
-- mounted in forward section of wheelhouse panel secured to the chassis frame
rail.
-- Recessed with width permitting removal and insertion of receiver pin
-- includes a sub-surface screen printed polycarbonate label with chrome bezel
that reads "Max. Load Rating - 10,000 LBS" (Hackney P/N #818465)
1 HS
*** NOTE TO ENGINEERING/SHOP: -- Recessed in wheelhousing skirt panel to
match 07F09251. ***
15-51-0000
S
<
PLUG, POWER W/1/0 WIRING FOR PORTABLE WINCH (EA)
-- includes dust cap for power plug when no in use
-- label installed adjacent to the power plug indicating “12VDC WINCH POWER”
(Hackney P/N #818461)
Locations:
- one (1) adjacent to each side receiver, streetside (left) and curbside (right)
- one (1) adjacent to the rear receiver
3 HS
10/28/2015
PART NO
16-10-1510
S
DESCRIPTION
< > TOW EYE PLATES - REAR - BLACK (PR)
-- Bolted to frame channels
-- Powder-coated black
-- 5"H x 1" thick with 3" diameter hole
Page 4
QTY
ID
1 HS
Location: Rear body panel under rear compartment
17-10-0000
20-00-3000
20-01-0000
20-11-1132
<
<
TRAILER HITCH RECEIVER - CLASS III/IV
-- Rated for up to 10,000 lbs. trailer weight
-- Rated for up to 1000 lbs. tongue weight
-- with 7-pin male electrical connector and female pigtail
-- includes a sub-surface screen printed polycarbonate label with chrome bezel
that reads "Max. Load Rating - 10,000 LBS" (Hackney P/N #818465)
1 HS
BODY and FRAME OPTIONS
FRAME MODIFICATION - LR & PL BODY
BODY CONSTRUCTION - LIGHT RESCUE - Bid Format
-- 100% aluminum construction - 10 year structural warranty
-- All compartments rated at a minimum of 2300 lbs load capacity each
-- 1/8" smooth aluminum reinforced floors
-- 3/16" smooth aluminum reinforced wheelhouse compartment floor
-- All compartment floors raised 1", unless otherwise noted
-- All compartments with roll-up doors, painted to match body & cab with integral
door tracks - compartment interior width equal to door pass-thru
-- 3" slats
-- Bright aluminum tread plate roof welded around perimeter
-- .190 smooth aluminum front and rear covers
-- Radius corner and roof rail extrusions - no blunt or formed edges
1 HS
1 HS
1 HS
< > BODY - LR0764 - 51/48/40 - 84"CA - F-550 4-DR/4WD
Street (Left) Side:
-- S-1 - 51"W x 64/44"H x 26/90"D
-- S-2 - 48"W x 39"H x 90"D
-- S-3 - 40"W x 64"H x 25"D
Curb (Right) Side:
-- C-1 - 51"W x 64/44"H x 26/90"D
-- C-2 - 48"W x 39"H x 90"D
-- C-3 - 40"W x 64"H x 25"D
Back (Rear):
-- B-1 - 38"W x 47"H x 40"D
1 HS
-- includes 3" door slats
-- Includes new two piece rear body panel
-- Includes vents in back wall of lower C-3 compartment as per drawing
BODY OPTIONS
ROOF, BRIGHT ALUMINUM TREADPLATE - STD PATTERN
ROLLERS, STAINLESS STEEL ROLL-UP DOOR - ILOS - (Ea. Comp't Door)
WHEELHOUSING SKIRT PANEL - BRIGHT ALUMINUM TREADPLATE
FRONT BODY PANEL - BRIGHT ALUMINUM TREADPLATE
.125" welded
1
1
1
1
1
FENDERETTES, STAINLESS STEEL (PR)
FUEL/DEF FILLER W/HINGED ACCESS DOOR - F450/550 only
-- Hackney P/N #825774 -- CPI P/N #
-- polished flange with directional grind finish on door
1 HS
1 HS
<
ULTRA-LOW SULFUR DIESEL FUEL ONLY LABEL
-- Hackney P/N #818921
-- sub-surface screen printed polycarbonate label with chrome trim bezel installed
adjacent to the fuel fill
1 HS
<
DEF FLUID LABEL
-- sub-surface screen printed polycarbonate label with chrome trim bezel installed
1 HS
20-51-0110
20-61-0200
20-71-0010
20-71-0110
<
20-71-0320
20-72-2002
<
20-72-3000
20-72-3100
HS
HS
HS
HS
HS
10/28/2015
PART NO
S
DESCRIPTION
QTY
Page 5
ID
adjacent to the DEF fluid fill
22-21-0000
22-25-2000
22-25-5500
<
22-40-3000
22-40-3105
<
EXTERIOR BODY OPTIONS
STONE GUARDS, FRT & REAR - D/P CORNERS (4)
BUMPER, REAR STEP BRIGHT TREAD PLATE
SIGN - "DANGER - DO NOT RIDE ON REAR STEP"
-- Hackney P/N #806463
-- sub-surface screen printed polycarbonate label with chrome trim bezel
-- Affix over rear step bumper
-- "DANGER - DO NOT RIDE OR STAND ON REAR BUMPER/STEP WHILE
VEHICLE IS IN MOTION. DEATH OR SERIOUS INJURY MAY RESULT"
> WHEEL CHOCK - ZICO AC-2 (EA)
WHEEL CHOCK BRACKET - HORIZONTAL FOR ZICO AC-2 (EA)
-- Ziamatic #QCH-2 horizontal holder with mounting hardware
1
1
1
1
HS
HS
HS
HS
2 HS
2 HS
Location(s): Streetside, aft of rear wheels as per drawing
< > LICENSE FRAME W/LIGHT-SURFACE MNT-CPI C30004
-- Hackney P/N #803502
Location: Centered under rear bay as per drawing
22-50-3000
22-51-1000
23-11-0506
<
23-11-0550
<
1 HS
MUD FLAPS, REAR (PR) BLACK RUBBER
INTERIOR COMP'T OPTIONS
UNISTRUT "C" CHANNEL (set of 4) - up to 50"L
Location: C-3 on right side of partition
1 HS
1 HS
1 HS
RECESSED ADJUSTABLE SHELF TRACK (EA)
Starting just above cross-sill to approx. 3" below top of section cover
7 HS
Locations:
-- S-1 - forward wall and forward side of partition
-- S-2
-- S-3
-- C-1 - forward wall and forward side of partition
-- C-2
-- C-3
-- B-1
23-11-2000
S
<
SHELVING - SO
-- heavy-duty .190 aluminum open-end flange on four sides
-- sub-surface screen printed polycarbonate label installed on front shelf flange
that reads "WARNING - Maximum Capacity: 500 LBS. - Load must be evenly
distributed." - Hackney P/N #818507
9 HS
Location(s)/Size(s):
-- S-1, (1) 29"W x 44"D -- adj between partition and forward wall
-- S-3, (2) 39"W x 24"D -- adj
-- C-1, (2) 29"W x 44"D -- adj between partition and forward wall
-- C-3, Refer to item 24-39-SP01 for full details
23-11-2101
23-21-0500
S
<
SHELF - EXTENDED FLOOR - PERMANENT (EA)
-- heavy-duty aluminum with flange on four sides
Locations w/size:
-- S-1 - 19" from floor to top of extended floor
-- C-1 - 19" from floor to top of extended floor
< > TRAY, SLIDE-OUT 300# - SLIDEMASTER - SO
-- Sliders - Innovative SlideMaster SM3LP
-- Black powder-coating on slider rails
-- heavy-duty .190 aluminum w/3" welded corner flange on four sides
-- Yellow/Black safety stripe tape on each side of tray
-- sub-surface screen printed polycarbonate label installed on front shelf flange
that reads "WARNING - Maximum Capacity: 300 LBS. - Load must be evenly
distributed." - Hackney P/N #818508
2 HS
1 HS
10/28/2015
PART NO
S
DESCRIPTION
QTY
Page 6
ID
Locations w/size:
-- S-3, (1) 24"W x 24"D -- fixed on floor between partition and aft wall
23-21-1000
S
<
TRAY, SLIDE-OUT 600# - SLIDEMASTER - SO
-- Sliders - Innovative SlideMaster SM3MP
-- Black powder-coating on slider rails
-- heavy-duty .190 aluminum w/3" welded corner flange on four sides
-- Yellow/Black safety stripe tape on each side of tray
-- sub-surface screen printed polycarbonate label installed on front shelf flange
that reads "WARNING - Maximum Capacity: 600 LBS. - Load must be evenly
distributed." - Hackney P/N #818509
3 HS
Locations w/size:
-- S-2, (1) 47"W x 44" -- fixed on floor
-- C-2, (1) 47"W x 44" -- fixed on floor
-- B-1, (1) 37"W x 40" -- fixed on floor
23-21-5000
S
< > TRAY, SLIDE/TILT 250# - SLIDEMASTER - SO
-- Black powder-coating on slider rails
-- heavy-duty .190 aluminum w/3" welded corner flange on four sides
-- Yellow/black safety stripe tape on each side of tray
-- sub-surface screen printed polycarbonate label installed on front shelf flange
that reads "WARNING - Maximum Capacity: 250 LBS. - Load must be evenly
distributed." - Hackney P/N #816554
-- sub-surface screen printed polycarbonate label installed on front shelf flange
that reads "WARNING - SERIOUS INJURY MAY OCCUR - if slide is handled
carelessly or if product stored in tray is not properly secured." - Hackney P/N
#816553
1 HS
Locations w/size:
-- B-1, (1) 34"W x 38" -- adj
23-80-1000
S
23-80-4100
24-30-2000
S
< > TURTLE-TILE - UP TO 48"x40" (Black)
COLOR: Black
LOCS: In all shelves, trays and floors
<
TURTLE-TILE EDGE RAMPS (EA 12" SECTION)
PARTITION - HORIZONTAL HD 2" FRAMED TYPE
- 2" thick partition with 2.25" end caps
18 HS
19 HS
1 HS
Location: S-1/C-1 - 30" from forward wall to section cover of partition
24-31-2000
S
< > DIVIDER, ALUMINUM 3/16"
LOC:
-- S-3, mounted on floor adjacent to spring shackle cover and to be 34" high as
per drawing
-- C-3, Refer to item 24-39-SP01 for full details
24-39-SP01
X
<
CRIBBING RESTRAINT - FULL COMPARTMENT
-- continuous aluminum hinge
-- Southco gray lever-style latch (non-locking)
-- Rear of each door equipped with anti-jam guards for latches
-- Compartment to be enclosed from the top of compartment
-- 9" fan installed on top of compartment to pressurize when shoreline is plugged
in
-- .190" divider installed 31.50" from aft wall and to be full height
-- (2) adjustable shelves installed between .190" divider and aft wall ** Allow
enough depth for door mounted compartment lights **
-- (1) fixed shelf installed 32" from floor to top of shelf, between .190" divider and
forward wall ** Allow enough depth for door mounted compartment lights **
-- (1) fixed shelf installed just above spring shackle compartment, between .190"
divider and forward wall
Location: C-3
2 HS
1
10/28/2015
PART NO
24-45-0100
S
S
<
DESCRIPTION
FIRE EXTINGUISHER (2) COMP'T - TILTING
Accommodation for 80 B;C Dry Chem and/or 2.5 gallon water
-- .188 Aluminum plate
-- Stainless steel continuous type hinge on lower front allowing comp't to tilt
outward
-- Restraint to hold comp't in tilted position for removing and inserting
extinguishers
-- Stainless steel handle on upper face
Page 7
QTY
ID
1 HS
Location: S-3
25-40-1000
S
< > STOKES/BACKBOARD TUNNEL- 1-STOKES; 2-BACKBOARD
-- Dimensions: 9"H x 48"W x 88"D
-- Hinged door with slam-type latch on each end
-- .125 aluminum construction
1 HS
Location: S-2/C-2 above compartment
25-40-4800
S
< > LADDER STORAGE COMP"T
-- Dimensions: 9"H x 30"W x 65"D for Little Giant
-- Hinged door with slam-type latch on each end
-- .125 aluminum construction
1 HS
Location: C-1, between partition and forward wall
25-45-0100
S
< > TOOL BOARD TRAY - TRANSVERSE - UP TO 85L X 33H
-- Black powder-coating on slider rails
-- heavy-duty .190 aluminum w/3" welded corner flange on four sides
-- 1.25" thick frame type vertical divider installed in tray
-- Yellow/Black safety stripe tape on each side of tray
-- upper section supported between two fiberglass glider angles
-- 1" divider installed 6" from aft side flange
-- sub-surface screen printed polycarbonate label installed on front shelf flange
that reads "WARNING - Maximum Capacity: 1000 LBS. - Load must be evenly
distributed." - Hackney P/N #818510
1 HS
Size: Tray 18" wide1" partition off-set 6" from aft side to permit space for SCBA's
on forward side
Location: S-1/C-1 between partition and aft wall
25-50-3006
S
< > SCBA STORAGE MODULE - ALUMINUM (5)
- accommodates up to a 7.25" diameter cylinder
- interior dimensions of each compartment: 7.50" x 7.50" x 24"
- constructed of a minimum .125" thick aluminum sheet
- 1/16" thick ribbed rubber sheet installed on side and bottom walls of each
storage space with rubber bumper provided on rear wall
- four (4) 1/2" holes provided in rear wall of each space for ventilation
1 HS
Location: C-1 suspended beneath extended floor
40-00-0010
41-00-0000
EXTERIOR OPTIONS
PAINT OPTIONS
< > PAINT BODY - LIGHT RESCUE - ONE COLOR
-- Clear urethane top coat - mirror finish (no "orange peel" effect)
COLOR: White
CODE/BRAND: match Ford cab
1 HS
1 HS
1 HS
< > DO NOT RE-PAINT CAB
I acknowledge that I have requested the chassis cab to be painted by the OEM
chassis manufacturer the specified color. I understand that Hackney will make
every attempt to match the body color to the cab color but can not guarantee an
exact color match. I further acknowledge that the finish on the chassis cab may
have some orange peel effect and may not not have the same luster as the body.
1 HS
Signed: _______________________________________
10/28/2015
PART NO
42-12-0000
S
42-90-0500
S
DESCRIPTION
<
TOUCH-UP PAINT, ONE QUART
COLOR(S):
< > COMPARTMENT WALLS/FLOORS COATING - MULTISPEC (ea. comp't)
Rust-Oleum Multispec
-- Does not include shelving, trays or other detachable equipment or components
-- Note: Fill all seams, rivet heads and between welds
Page 8
QTY
ID
1 HS
7 HS
Color: Silver Gray
UNDERCOATING CAB, FRAME & BODY
LETTERING and GRAPHICS
< > CHEVRON STRIPE - REAR BODY W/NO REAR DOOR - LIGHT RESCUE
-- 6" alternating stripes @ 45-degree angles
-- covers complete rear of body with including the rear hinged door(s)
-- 6" Reflexite Diamond Grade Conspicuity #V98-030 Solid Red and V98-069 FL
Yellow Green chevron stripe
42-99-0000
43-20-8005
1 HS
1 HS
1 HS
-- perimeter edge of the chevron sealed with a 3M 8518S clear edge seal tape
43-29-0000
X
50-00-1501
S
<
CUSTOM GRAPHICS PACKAGE - TEMPORARY
TBD
12VDC ELECTRICAL OPTIONS
< > ELECTRICAL SYSTEM - VISIONMUX - Commercial Chassis
-- 12VDC electrical system
-- Electrical distribution panel located in the ceiling of C-1 bay
-- Features 9-position switch panel panel mounted in center console; switches to
illuminate in the center when activated
-- Engine automatic high idle
-- Built in load manager
-- Low volt alarm in front of cab console
-- (1) Green LED "Power On" indicator light
-- (1) Green LED "Spare" indicator light
-- (1) Red LED "Tower Up" indicator light
-- (1) Red LED "Low Voltage" indicator light
1
1 HS
1 HS
-- TOP ROW LEFT: NO S DESCRIPTION QTY ID
#1 - E MASTER
#2 - BLOCKING LIGHTS
#3 - SPARE
-- TOP ROW RIGHT:
#4 - HORN/SIREN
#5 - SPARE
#6 - GENERATOR
-- BOTTOM ROW LEFT:
#7 - LEFT SCENE
#8 - RIGHT SCENE
#9 - REAR SCENE
50-05-0000
<
AMP DRAW REPORT - NFPA 1901, Section 9-15
Placed in Owners Manual at time of delivery
1 HS
50-06-1100
<
SAFETY INTERLOCK SYSTEM - LIGHT DUTY CHASSIS
Warning and disable mode activated by following components:
1. Light tower
1 HS
<
CAB CONSOLE - FLOOR MOUNT - FORD F-550 - VISIONMUX/V-MUX
-- Havis-Shields model #1C-3010 console with model #C-AP-1395-L accessory
pocket with lid
-- black powder-coated finish
-- minimum 13" long x 8" wide carpeted storage compartment with lockable
hinged lid
-- C-MC - Mike Clip
1 HS
50-10-0012
S
10/28/2015
PART NO
S
DESCRIPTION
QTY
Page 9
ID
-- DELETE C-ML-LP2
-- (2) 12VDC power point receptacles
Location: cab floor between driver and officer seats
50-20-0200
50-40-0110
<
BRACKET- HAVIS-SHIELDS SIREN FOR WHELEN 295-Series
-- Hackney P/N #813280
-- Havis-Shields #C-EB30-MGC-1P
-- required for mounting of Whelen 295HFS series siren in console
DOT LIGHTING
< > CLEARANCE LIGHTS, LED & REFLECTORS W/CENTER REAR THIRD BRAKE
Tecniq T11-RR00-1
-- 15"L x 1.25"H x 0.5" thick
-- 11 LED's with red lens and chrome bezel
-- 0.4-amps
1 HS
1 HS
1 HS
Provides DOT regulation center rear marker lights in routine operation (left and
right outer and center lights).
All 11 lights activate with brakes
50-50-1300
< > STOP/TAIL/BACKUP/TURN - LED - WHELEN M6FCV4
-- Whelen M6FCV4 surface mount polished chrome housings
-- Whelen M6BTT - red brake (2)
-- Whelen M6BUW - white backup (2)
-- Whelen M6T - amber turn (2)
-- Whelen M6RC - red flasher at bottom (2)
1 HS
50-55-1200
< > TRAFFIC ADVISOR - WHELEN TAL85 LED - 8-LMAP - 48"
CONTROL HEAD LOC: Cab console
Includes 15' extension cable
1 HS
51-10-1810
<
12VDC APPARATUS ILLUMINATION and OPTIONS
12VDC SIDE SCENE/FLOOD LIGHTS
SCENE LIGHT - SIDE - WHELEN M9 LED OPTI-SCENE (EA)
-- Whelen #M9LZC surface mount LED opti-scene light with Whelen #M9FC
chrome flange
-- Surface mounted on upper left and right side of body
1 HS
1 HS
4 HS
Locations: (2) Streetside/curbside as per drawing
51-10-2850
<
12VDC REAR SCENE/FLOOD LIGHTS
SCENE LIGHT - REAR - WHELEN M9 LED OPTI-SCENE (EA)
-- Whelen #M9LZC surface mount LED opti-scene light with Whelen #M9FC
chrome flange
-- Surface mounted on upper rear body panel
1 HS
2 HS
Locations: (1) Streetside/curbside of rear body door as per drawing
51-11-0100
51-11-0150
51-19-0110
<
12VDC FRONT SCENE/FLOOD LIGHTS
SCENE LIGHT - REAR REVERSE ACTIVATED - V-MUX
SCENE LIGHT - SIDE REVERSE ACTIVATED - V-MUX
GROUND LIGHTS - TECNIQ LED - UNDERBODY MOUNTED (EA)
-- E10-WS00-1 LED ground light with stainless steel angled bracket
-- 0.35-amps each
-- 6.5" x 3.3"
-- 675 lumens each
-- Angled stainless steel bracket with a light beam angle of approximately 120
degrees x 50 degrees
Locations:
-- (1) ea. forward of left & right rear wheel
-- (1) ea. aft of left & right rear wheels
1
1
1
5
HS
HS
HS
HS
10/28/2015
PART NO
S
DESCRIPTION
QTY
Page 10
ID
-- (1) under rear step bumper
Activated in the following scenarios:
1. When any body compartment door is opened
2. Manually from respective scene light switches
3. When the apparatus is shifted to the reverse model
51-50-1800
<
12VDC COMPARTMENT and INTERIOR LIGHTING
COMPARTMENT LIGHTS - LED STRIP - 12" RECESSED
-- Hackney P/N #366633
-- SoundOff P/N #ECVCLLED12
-- recessed in the aft compartment wall <<unless otherwise specified>>
1 HS
4 HS
Locations:
-- S-2, forward wall
-- S-2, aft wall
-- C-2, forward wall
-- C-2, aft wall
51-50-1810
S
<
COMPARTMENT LIGHTS - LED STRIP - 24" RECESSED
-- Hackney P/N #366634
-- SoundOff P/N #ECVCLLED24
-- recessed in the aft compartment wall <<unless otherwise specified>>
2 HS
Locations:
-- S-1, forward side of 2" partition
-- C-1, forward side of 2" partition
51-50-1825
<
COMPARTMENT LIGHTS - LED STRIP - 36" RECESSED
-- Hackney P/N #366635
-- SoundOff P/N #ECVCLLED36
-- recessed in the aft compartment wall <<unless otherwise specified>>
6 HS
Locations:
-- S-1, aft side of 2" partition
-- S-1, aft wall
-- S-3, aft wall
-- C-1, aft side of 2" partition
-- C-1, aft wall
-- B-1, streetside wall
51-50-1850
<
COMPARTMENT LIGHTS - LED STRIP - 42" RECESSED
-- Hackney P/N #366636
-- SoundOff P/N #ECVCLLED42
-- Lights mounted on hinged doors shall use orange coil cord to connect electrical
circuits
2 HS
Locations:
-- C-3 - mounted on fore and aft swing out cribbing door
51-50-SP01
X
<
COMPARTMENT LIGHT - 4" LED
Tecniq model #E06-WS00-1
-- 4" in diameter
-- Stainless steel surface mount trim bezel
-- 0.24-amps each
-- 300 lumens (ea) - six (6) white LED's
-- 77-degree light beam angle toward the walking surface
2
Locations:
-- S-1, under secondary floor
-- C-1, under secondary floor
51-55-1000
<
COMP'T OPEN WARNING & AUTO ACTIVATION - (per req'd switch)
Activation switch incorporated into the "Door Open" circuit.
In the event a door is not properly closed and/or secured, a red warning light will
illuminate when any door is opened and vehicle placed into "drive" mode.
1 HS
10/28/2015
PART NO
51-56-0100
S
<
DESCRIPTION
COMP'T OPEN WARNING LIGHT - LED
-- Hackney P/N
-- TecNiq D14-R000-1 Oval - 1.46 x 0.80
Page 11
QTY
ID
1 HS
Location: Centered in forward overhead headliner
54-01-SP01
X
NFPA 1901 WARNING LIGHTS
LIGHT BARS
< > WHELEN FREEDOM IV F4N2QLED- 55" LIGHT BAR ** SPECIAL **
-- Special FDIC lightbar. Refer to quote in file
1 HS
1 HS
1
Location: Cab roof
***Reference QW #02-10-1010 for OAH (overall height) restriction.***
54-10-0731
<
LOWER ZONE A - FRONT CAB WARNING LIGHTS
WHELEN 50R02ZCR LINEAR SUPER-LED (2) - NO FLANGE
-- requires polished cast aluminum light housing
1 HS
4 HS
Locations:
- one (1) streetside (left) and curbside (right) of the cab grille
Lens: Clear
54-11-1010
<
LIGHT HOUSING - GRILLE - 2011 F-550 - WHELEN 500 SERIES TIR6 (PR)
- Cast Products P/N #LH52611-1 (passenger)
- Cast Products P/N #LH52612-1 (driver
- polished cast aluminum light housing
4 HS
Location(s):
- LH52611-1 mounted on curbside (right) of the grille
- LH52612-1 mounted on streetside (left) of the grille
54-20-0831
<
LOWER ZONE B/D - CAB INTERSECTION WARNING LIGHTS
WHELEN 50R03ZCR TIR6 SUPER-LED (2) - NO FLANGE
-- polished cast aluminum housing required for mounting
1 HS
1 HS
Locations:
- one (1) streetside (left) and curbside (right) of the front cab fenders
Lens: Clear
54-20-1010
<
LIGHT HOUSING - INTERSECTION - 2011 F-550 - WHELEN 500 SERIES TIR6
(PR)
- Cast Products P/N #LH52707-1 (passenger)
- Cast Products P/N #LH52708-1 (driver
- polished cast aluminum light housing
1 HS
Location(s):
- LH52707-1 mounted on curbside (right) of the fender
- LH52708-1 mounted on streetside (left) of the fender
54-21-SP01
X
<
LOWER ZONE B/D - LOWER SIDE BODY WARNING LIGHTS
WHELEN M6RC LINEAR SUPER-LED (4)
-- Whelen M6RC red linear Super-LED warning light with M6FC chrome flange
1 HS
1
Locations:
Locations: one (1) fore and aft of the lower body crash rail, streetside (left) and
curbside (right)
LED Color: Red
Lens: Clear
LOWER ZONE C - REAR BODY WARNING LIGHTS
1 HS
10/28/2015
PART NO
54-25-3009
S
S
54-30-0678
<
DESCRIPTION
WHELEN M6RC LINEAR SUPER-LED (2)
Included in taillight assembly
<
UPPER ZONE B/D - SIDE BODY WARNING LIGHTS
WHELEN M9RC LINEAR SUPER-LED (4)
-- Whelen M9R red linear Super-LED warning light with M9FC chrome flange
Page 12
QTY
ID
1 HS
1 HS
1 HS
Location(s): one (1) fore and aft of the upper roof rails, streetside (left) and
curbside (right)
LED Color: Red
Lens: Clear
54-31-0482
<
UPPER ZONE C - REAR BODY WARNING LIGHTS
WHELEN M9RC LINEAR SUPER-LED (2)
-- Whelen M9RC linear Super-LED light with a M9FC chrome flange
1 HS
1 HS
Location: upper rear body panel, two (2) streetside (left) and curbside (right)
LED Color: Red
Lens: Clear
WHELEN NFPA NFPA CERTIFICATE of COMPLIANCE
Run Whelen compliance Checker against NFPA warning light Bills of Materials
-- Insert certificate in Owner's Manual and in Customer files
54-99-9900
<
55-22-1000
SIRENS and SPEAKERS
< > SIREN - WHELEN ELECTRONIC - 295SLSA1
Location: Cab console
1 HS
1 HS
HORN/SIREN SWITCH
< > SPEAKER, SIREN - F-550 - THRU-THE-BUMPER (DRIVER/PASSENGER) WHELEN
-- Whelen SA315FIP (through-the-bumper mount)
-- Hackney P/N #
1 HS
1 HS
55-30-1000
55-41-5080
1 HS
Location: one (1) streetside (left) and curbside (right) of the front bumper
12VDC MISCELLANEOUS OPTIONS
< > 12VDC POWER STRIP - (6) TERMINALS - CAB
Blue Seas - Fuse Block ATO - 6-circuit with ground
#196977474
-- Clear insulating cover
-- Copper buses and fuse clips
-- 30-amp rating per circuit
-- Accepts ATC blade type fuses and plug-in circuit breakers
8-ga primary power cable
58-50-1000
1 HS
1 HS
Location: Cab console
58-80-1000
58-82-SP01
X
<
BACK-UP ALARM - FEDERAL 210333
REARVIEW COLOR CAMERA W/NIGHTVISION & MONITOR
Federal Signal
1 HS
1
-- Rearview automatically displayed when in reverse mode.
-- Manual operation for secondary activation
-- LCD monitor inside of rear view mirror. Part # CAMLCD-MIR
-- Standard Federal Signal back-up camera. Part # CAMCCD-REARNTSC
59-59-0000
COMMUNICATIONS AND AUDIOVISUAL SYSTEMS
< > ANTENNA COAXIAL W/CONNECTOR - MOTOROLA 17'
-- PL259 soldered on at the interior termination point
-- 1-1/8" brass base for Motorola antenna on exterior roof
1 HS
1 HS
10/28/2015
PART NO
S
DESCRIPTION
QTY
Page 13
ID
Termination Point - EXT: Cab roof, behind lightbar
Termination Point - INT: Cab console
60-00-0500
61-02-0606
<
240/120VAC ELECTRICAL OPTIONS
ELECTRICAL - 120/240V - STANDARDS REQUIREMENTS - Bid Format
GENERATOR and OPTIONS
GENERATOR, 6KW HYDRAULIC - SMARTPOWER LR-6
Smartpower 1701806
FORD F550 application only
Does not require a LiveDrive system
Smart Power kit includes 249PTO
1
1
1
1
HS
HS
HS
HS
Rating: 7500 watts peak 6200 watts continuous
Volts: 120/240 volts
Phase: Single, 4 wire
Frequency: 60 Hz
Amperage: 46 amps @ 120 volts or 23 amps @ 240 volts
Engine speed at engagement: 1300-1500 rpm fixed
Operation range: 400 to 3200 RPM
Location: S-1, mounted on floor
61-08-2000
61-60-1012
<
S
UL DIELECTRIC VOLTAGE WITHSTAND TEST - U.L.
-- Hackney P/N #818034
-- UL test results to be included in Owner's Manual
-- Tested to NFPA 1901, Chapter 23.16.2
< > BREAKER BOX - 12-PLACE, 120/240VAC
-- sub-surface screen printed polycarbonate label installed for identification of
circuit breakers
1 HS
1 HS
Location: S-1 - top of compartment angled downward as per drawing
62-75-0000
S
<
120/240VAC OUTLETS, REELS and OPTIONS
TRANSFER RELAY, AUTOMATIC - 30 AMP
-- Limited to outlets on same circuit only
-- Automatically transfers power from generator to shorepower
1 HS
1 HS
Circuits to be powered: outlets in S-1 and C-1
63-10-1000
S
< > OUTLET 120V DUPLEX INTERIOR W/GFI, 20A (EA)
-- sub-surface screen printed polycarbonate label with chrome bezel reading
"120VAC - 20A" above each outlet
-- Stainless steel cover plate
-- powered by generator and shorepower
2 HS
Locations:
-- S-1 - forward wall
-- C-1 - forward wall
64-00-2000
< > CORD REEL, ELECTRIC HANNAY ECR1616-17-18
-- Overall Dimensions: 19.50"W x 19"D x 18.12"H
-- sub-surface screen printed polycarbonate label with chrome bezel that reads
"120VAC REEL REWIND" next to rewind button (Hackney p/n #65105)
-- Type of cord: 10/3 yellow
-- Capacity: 200'
-- Connection: L5-20C
-- Includes captive roller assembly and ball stop
A label (Hackney p/n #813149) will be provided in a readily visible location
adjacent to any permanently connected reel. It will indicate the following:
-- current rating
-- current type
1 HS
10/28/2015
PART NO
S
DESCRIPTION
QTY
Page 14
ID
-- phase
-- voltage
-- total cable length
-- Ground continuity monitor on plug
Location: S-3
65-30-6069
S
<
120/240VAC FLOOD LIGHTS and OPTIONS
KNIGHT LIGHT - KL 415A-W2 6x22- W AC WHELEN PFP2 LED
Watts............................................................. 1000
Output........................................................... 15,000 lumens
Watts (Total)................................................... 900
Output (Total)................................................. 90,000 lumens
Nested HxWxD.............................................. 14" x 47" x 33"
Fully Upright HxWxD..................................... 87.5" x 52" x 33"
Weight................................................................approx. 136 lbs. AutoPark
feature
-- sub-surface screen printed polycarbonate label with chrome bezel that reads
"TOWER UP" next to red alert light on generator panel
1 HS
1 HS
-- Red light adjacent to the Visionplex switch panel that is labeled "TOWER UP"
Tower Location: Forward body roof as per drawing
Tower Control Location: S-1, on generator control panel
***Reference QW #02-10-1010 for OAH (overall height) restriction.***
< > LIMB GUARD, ANGLED FRONT OF LIGHT TOWER - D/P
-- constructed of a minimum .125" bright finish aluminum treadplate
65-30-9000
1 HS
***Reference QW #02-10-1010 for OAH (overall height) restriction.***
85-20-2900
S
120/240VAC MISCELLANEOUS OPTIONS
HYDRAULIC TOOL OPTIONS
< > HYD REEL MOUNTING PLATES AND WIRING
-- "HYD REEL REWIND" metallic tag next to rewind button
-- 10 ga power wiring to solenoid with 40 amp fuse
-- Rewind button supplied with customer furnished reel
-- Mounting plate across top of compartment
1 HS
1 HS
1 HS
Location: B-1
89-15-0200
S
MISCELLANEOUS EQUIPMENT and SERVICES
< > FIRE EXTINGUISHER - 20A-80B:C - NFPA REQ'D
- Hackney P/N #802640
1 HS
1 HS
Location: S-3 in tilt-out tubes
89-15-1000
S
< > FIRE EXTINGUISHER - 2-1/2 GAL PRESSURIZED WAT
- Hackney P/N #802643
1 HS
Location:S-3 in tilt-out tubes
89-99-9600
<
DOT SAFETY KIT
Place in cab at time of delivery for DOT compliance.
-- Includes: Triangle Marker set; (1) flashlight; (1) 2-1/2# BC extinguisher
1 HS
89-99-9910
<
NFPA1901 INCOMPLETE VEHICLE FORM
Use Original Word document to include or delete actual compliance equipment
1 HS
ADMINISTRATIVE - FIXED
FINAL QC - LIGHT RESCUE
1 HS
1 HS
98-00-5101
10/28/2015
PART NO
98-01-1000
98-01-1010
98-10-1500
98-11-1000
99-99-9990
S
DESCRIPTION
> MANUAL, HACKNEY OWNERS W/SCHEMATICS
MANUAL, OWNERS - EXTRA COPIES
PRE-DELIVERY CLEAN-UP - CAB & BODY
> FUEL TANK FULL AT FACTORY DELIVERY (up to 50-gallon tank)
ADMINISTRATIVE - VARIABLE
ADMINISTRATIVE - TERMS and CONDITIONS
< CUSTOMER SUPPLIED COMPONENTS STATEMENT
This order includes line item(s) that require customer supplied components for
completion. It is understood that timely receipt of these components is critical to
meeting the delivery date commitments associated with the contract. Failure to
provide these components on the required shipment dates could be cause for
removal of the vehicle from production until such time as components are
received and thus cause the delivery date commitment or applicable late delivery
penalties to become null and void. Additionally, delay (unless completely
unavoidable) in receipt of components could result in added cost to the contract
price. Components for this contract are noted in the applicable line item herein
and are required to be received at Hackney on or before:
______________________________
QTY
1
1
1
1
1
1
1
Page 15
ID
HS
HS
HS
HS
HS
HS
HS
99-99-9991
<
SHOP ORDER TERMS & CONDITIONS
-- REVIEW each line item and corresponding Shop Notes for completeness and
accuracy. This Shop Order is an interpretation of the original contract and, in
correlation with the Engineering Drawings included herein, is the only document
used for manufacturing of this order.
-- Some Part Numbers may have an empty line in the Shop Note that requires
further information to complete the Shop Order. This order can not be released to
Manufacturing upon such time as all pertinent information is provided. Failure to
provide this information will result in a delay in final delivery of the apparatus and
void any contractual delivery times (see original Contract agreement).
-- CORRECTIONS are be clearly marked next to the corresponding part number
and any corresponding location on the Approval Drawing. Major corrections may
require a second approval process, as determined by Engineering.
-- APPROVAL of this order is required by the signature of a duly authorized
representative of the purchaser (see last page of Shop Order). It can be approved
"As Is With No Changes" or "As Is With Changes Noted". Approvals with
"Changes Noted" will be corrected and a copy of the corrected Shop Order will be
returned to the purchaser for verification. No further approvals are required. This
also applies to the corrsponding Approval Drawing.
-- REQUIRED RETURN TIME - This Shop Order is required to be returned not
later than 10 days after receipt to Hackney with signatures. Failure to return in
this time period may result in delay in contractual delivery date.
1 HS
99-99-9992
<
CONDITIONS OF ACCEPTANCE
This Shop Order and any preceding chassis related specifications supersedes
the customers issued specifications and reflect the apparatus proposed to be
manufactured and delivered by Hackney. All applicable exceptions were recorded
separately and titled "Exceptions or Clarifications" in the submitted Bid/Proposal.
Final inspection of the completed apparatus will be conducted using the Proposal
Specifications and Engineering Proposal Drawing(s).
1 HS
Changes made to this order after receipt of approvals are subject to a minimum
of $250.00 engineering surcharges, plus cost of components. No changes will be
permitted after production has started.
To facilitate an accurate inspection environment, Hackney will, upon the request
of the purchaser, schedule specified inspections during regular working hours
Monday through Friday. Said inspections will be at the discretion of the
purchaser. Hackney will make the following factory personnel available during the
inspection process: sales administrator responsible for the contract; engineering
representative familiar with the contract; production foreman or equivalent
assignment responsible for the manufacturing process of the contracted
apparatus and a representative of the upper management team authorized to
make decisions for the contractor.
10/28/2015
PART NO
99-99-9998
S
<
DESCRIPTION
TEST DRIVE & INSURANCE REQUIREMENTS
VEHICLE LICENSE PLATES/TAGS REQUIREMENTS: VT Hackney (VTH) may
issue temporary tags to a customer picking up a completed emergency vehicle
only for an out-of-state delivery. NC DMV laws do not permit VTH to issue
temporary tags for vehicles delivered within the State of North Carolina. If the
chassis is customer supplied or dealer supplied driveaway tags must be provided
by the customer/dealer. In the event VTH provides a temporary tag proof of
insurance must be provided prior to leaving the VTH premises. Temporary tags
are for the purpose of transporting the vehicle from the factory to the end users
location only and cannot be used once the vehicle is placed into service.
MANUFACTURER'S STATEMENT OF ORIGIN (MSO): VTH corporate risk
policy does not permit the release a MSO until such time as full payment is
received for the completed and accepted vehicle.
DRIVERS LICENSE: All drivers will be required to submit a valid driver's license,
a copy of which will be inserted into the Customer File. For vehicles with GVWR
of 26,001 or more the driver will be required, by North Carolina DMV Law, to
present a valid CDL (Commercial Driver's License).
TEST DRIVES: VTH's underwriter will not permit a non-employee to drive any
vehicle off its premises unless a copy of proof of insurance for the vehicle is
provided prior. A non-employee cannot operate a vehicle using a VTH
Manufacturer's license plate. Either a temporary tag or the customers tag must
be attached prior to the test drive, unless such is conducted within the VTH
campus. In the event any of the above conditions cannot be met by the customer,
VTH will provide a qualified VTH employee to drive the vehicle for the test with a
customer representative(s) on board.
Page 16
QTY
ID
1 HS