SmartPlant Electrical Basic Training Guide
Transcription
SmartPlant Electrical Basic Training Guide
SmartPlant Electrical 3.5 SmartPlant Electrical Basic User’s Training Guide Version 3.5 September 2005 SmartPlant Electrical Basic User’s Training Guide DELE2-PE-200011A SmartPlant Electrical 3.5 Copyright Copyright © 1999-2005 Intergraph Corporation. All Rights Reserved. Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and international treaty, and may not be provided or otherwise made available without proper authorization. Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) of the Contractor Rights in Technical Data clause at DFARS 252.227-7013, subparagraph (b) of the Rights in Computer Software or Computer Software Documentation clause at DFARS 252.227-7014, subparagraphs (b)(1) and (2) of the License clause at DFARS 252.227-7015, or subparagraphs (c) (1) and (2) of Commercial Computer Software--Restricted Rights at 48 CFR 52.227-19, as applicable. Unpublished---rights reserved under the copyright laws of the United States. Intergraph Corporation Huntsville, Alabama 35894-0001 Warranties and Liabilities All warranties given by Intergraph Corporation about equipment or software are set forth in your purchase contract, and nothing stated in, or implied by, this document or its contents shall be considered or deemed a modification or amendment of such warranties. Intergraph believes the information in this publication is accurate as of its publication date. The information and the software discussed in this document are subject to change without notice and are subject to applicable technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document. The software discussed in this document is furnished under a license and may be used or copied only in accordance with the terms of this license. No responsibility is assumed by Intergraph for the use or reliability of software on equipment that is not supplied by Intergraph or its affiliated companies. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT. Trademarks Intergraph, the Intergraph logo, SmartSketch, SmartPlant, and INtools are registered trademarks of Intergraph Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation. MicroStation is a registered trademark of Bentley Systems, Inc. Other brands and product names are trademarks of their respective owners. SmartPlant Electrical Basic User’s Training Guide SmartPlant Electrical 3.5 Table of Contents Preface.................................................................................................................................7 Introduction........................................................................................................................9 Training Prerequisites...................................................................................................9 Scope.............................................................................................................................9 Electricity and Electrical Engineering ........................................................................10 Workflow....................................................................................................................11 Smart Plant Electrical Modules ........................................................................................ 12 Electrical Equipment .......................................................................................................13 Generators and Power Sources ...................................................................................13 Create a Project Generator ................................................................................................ 13 Duplicate an Item.............................................................................................................. 13 Delete an Item ................................................................................................................... 14 Create Electrical Items in Reference Data Explorer ......................................................... 14 Loads...........................................................................................................................15 Create Motors ................................................................................................................... 15 Converting Equipment................................................................................................16 Create a Transformer ........................................................................................................ 16 Common Features in Smart Plant Electrical ..................................................................... 17 Properties Window (Property Grid).................................................................................. 19 Electrical Loads (Consumers)........................................................................................... 23 Static Loads, Heater Equipment Form.............................................................................. 28 Transformers and Other Types of Converting Equipment................................................ 30 Lab 1 ................................................................................................................................. 32 Tabular Editor .................................................................................................................35 Create a Table ................................................................................................................... 35 Lab 2 ................................................................................................................................. 46 Power Distribution Board ...............................................................................................48 Design of PDB Layout – General Arrangement ............................................................... 55 Lab 3 ................................................................................................................................. 59 Wiring Equipment ......................................................................................................62 Panels ................................................................................................................................ 62 Control Stations ................................................................................................................ 63 Local Panels and Junction Boxes...................................................................................... 64 Cables................................................................................................................................ 65 Parallel Cables .................................................................................................................. 83 Busways ............................................................................................................................ 84 Signals............................................................................................................................... 85 I/O Sets ............................................................................................................................. 85 Lab 4 ................................................................................................................................. 86 SmartPlant Electrical Basic User’s Training Guide 3 Table of Contents Propagating Default Data and Associations ..................................................................91 Look-Up Tables (LUT)...............................................................................................91 Create LUT ....................................................................................................................... 92 Apply Options................................................................................................................... 92 Apply Lookup Tables ....................................................................................................... 93 Apply Typical Circuit ....................................................................................................... 94 Apply Profile..................................................................................................................... 99 Assigning a Load to a PDB/Bus/Cell/Circuit ................................................................... 99 Batch Load Assignment.................................................................................................. 101 Assigning Control Stations to Loads .............................................................................. 105 Lab 5 ............................................................................................................................... 106 Cable Sizing ....................................................................................................................108 Ampacity Sizing .......................................................................................................110 Voltage Drop (VD) at Running (VDN) .......................................................................... 111 Voltage Drop at Starting Conditions (VDS) ................................................................... 111 Ambient Temperature Correction Factor........................................................................ 112 Calculating Maximum Allowable Power Cable Length ................................................. 112 Viewing All Possible Combinations and Acceptable Cable Sizes in Sizing Procedure . 114 Fault Short Circuit Cable Sizing ..................................................................................... 115 Properties Copied from Loads ........................................................................................ 117 Required Data for Sizing and Selection.......................................................................... 118 Refresh Load - Changes in Electrical Data of Load ....................................................... 119 Power Systems ................................................................................................................ 120 Batch Sizing of Cables.................................................................................................... 120 Replacing Cables ............................................................................................................ 121 Lab 6 ............................................................................................................................... 124 Reports ............................................................................................................................127 Report Writer ............................................................................................................127 Creating New Report Templates..................................................................................... 127 SmartPlant Reports Toolbar............................................................................................ 128 Editing Report Templates ............................................................................................... 133 Deleting Reports ............................................................................................................. 133 Running Reports ............................................................................................................. 133 Run Reports and Specify Items Through Tabular Editor................................................ 134 Shipped Reports .............................................................................................................. 134 Lab 7 ............................................................................................................................... 139 Electrical Engineer.........................................................................................................140 Lab 8 ............................................................................................................................... 141 Single Line Diagrams.....................................................................................................142 Generate a power distribution board-based SLD ....................................... 143 Generate an Electrical Engineer-based SLD................................................ 143 Single Line Diagram Drawing Options ......................................................... 144 Power distribution board-based SLD .............................................................. 144 4 SmartPlant Electrical Basic User’s Training Guide Table of Contents Managing the SLD ............................................................................................ 146 Lab 9 ............................................................................................................................... 147 Schematics ......................................................................................................................148 Typical blocks .......................................................................................................... 148 Create a Typical Block ......................................................................................... 150 Create a Typical Schematic ................................................................................ 151 Generating Schematics in Batch Mode........................................................................... 155 Create Templates (template for Schematic and SLD) ..................156 Lab 10 ............................................................................................................................. 158 Associating Documents ............................................................................................160 Define a Document Reference .................................................................. 160 Associate a Document ........................................................................................... 161 Lab 11 ............................................................................................................................. 162 Archiving Documents ....................................................................................................163 Global revisions ...............................................................................................167 Deliverable Project Reports (register report) ....................................168 Exercise .................................................................................................................... 168 Lab 12 ........................................................................................................................ 174 Miscellaneous Features..................................................................................................175 Batch Assignment of Control Station Cables ...................................175 External Drawings .......................................................................................................... 178 Transfer Switches .....................................................................................................180 Dual Power Source Equipment.................................................................................184 Exercise:.......................................................................................................................... 185 Rules in Operations that Involve Circuits ....................................................................... 191 Earth Loop Impedance Calculations in Cable Sizing ...............................................192 Metering Equipment and Protection Relay...............................................................193 Measure Transformers .................................................................................................... 194 Create Meters .................................................................................................................. 196 Protection Relays and Relay Functions .......................................................................... 197 Drag Metering Equipment to the Instrument Index ........................................................ 198 Working with Metering and Protection Relay Symbols in the SLD............................... 200 Cable Management System ......................................................................................204 Automating Cable to Drum Assignment......................................................................... 204 Cable Routing ...........................................................................................................207 Exercise........................................................................................................................... 208 Cable Routing Validation Rules ..................................................................................... 224 Introducing NEC Motor Tables Data .......................................................................228 Detailed Transformer Neutral Grounding Definitions .............................................231 Defining the Neutral to Ground of the Transformer Windings....................................... 232 Representing the Neutral Grounding of the Transformer in an SLD.............................. 236 SmartPlant Electrical Basic User’s Training Guide 5 Table of Contents Document Revision History ..........................................................................................238 6 SmartPlant Electrical Basic User’s Training Guide Preface This training guide introduces concepts, procedures, and features of SmartPlant Electrical. Send documentation comments or suggestions to [email protected]. SmartPlant Electrical Basic User’s Training Guide 7 Preface 8 SmartPlant Electrical Basic User’s Training Guide Introduction Training Prerequisites • An intermediate knowledge of electrical design • Familiarity with windows-based applications • A plant with default reference data • ‘Demo Training SLD’ drawing available. Scope The purpose of this document is to educate the user on Smart Plant Electrical (SmartPlant Electrical) operational procedures and methods, features and functionalities. The document contains the following sections: • Part 1: Electrical Equipment • Part 2: Tabular Editor • Part 3: Power Distribution Board • Part 4: Wiring Equipment • Part 5: Propagating Default Data and Association • Part 6: Cable sizing • Part 7: Reports • Part 8: Electrical Engineer • Part 9: Single Line Diagram • Part 10: Schematics • Part 11: Associate Document • Part 12: Archive Document • Appendix A: SLD Demo Project Note • The last section in each part is a lab. The asterisk sign before a lab exercise indicates that it is part of the ‘SLD Demo Project’. SmartPlant Electrical Basic User’s Training Guide 9 Introduction Electricity and Electrical Engineering Following is a brief synopsis of Electrical Engineering and Design and also some guiding principles that were employed in the creation of SmartPlant Electrical. The Electrical Distribution Network The electrical distribution network includes all the equipment and devices used to control and deliver electrical power safely and efficiently from the ‘incoming’ service to the ultimate end ‘users’ or ‘consumers’. Equipment The distribution network consists of: 1. Sophisticated equipment that in some cases is designed and manufactured for particular network-specific (or plant design-specific) use. 2. Standard or ‘typical’ equipment that has the same characteristics from device to device or even from project to project. SmartPlant Electrical has the ability to handle both cases. One advantage the user will discover about SmartPlant Electrical is that the ‘typical data’ need only be entered once and then copied as needed to other similar devices. Both typical and copied items of equipment will have specific parameters defined in the course of the design and recorded on the project documents and drawings. The equipment includes (but is not limited to): • Incoming utility feeders • Generators • Substations • Switchgear • Motor Control Centers • Local Control Equipment • Motors • Cables • Low Voltage Distribution Panels • Lighting • Heaters 10 SmartPlant Electrical Basic User’s Training Guide Introduction Electrical Engineering and Design Involves the design of those electrical parameters and equipment that make up the distribution and utilization network. Part of the design is also involved with correctly assembling all the ‘pieces’ to form a cohesive and robust system (with calculated results) to fill the current needs of the client as well as providing for future expansion. This design is all handled in a framework of recognized Codes (National and Local), Standards, and Accepted Practices. Another important function of electrical design is to develop and record accurate calculations related to specific electrical and physical phenomena that the engineer/designer uses daily. These design activities and the resulting design documents are ultimately used to: • Provide safety and adherence to codes, client requirements, and so forth. • Provide the contractor with direction and materials related needs during construction. • Provide documentation to the particular facility’s ‘technical libraries’ for future reference, and so forth. Documentation These engineering and design activities are presented to the facility and to the contractor in a variety of documents. Some of these documents will only be used during construction, however, some will form a part of the facility’s technical library. Some of these documents will include (but not be limited to): • Single Line Diagrams • Cable Schedules • Material Take-offs and Reports • Equipment List • Electrical Load Lists Workflow SmartPlant Electrical does not force a particular workflow, and thee are several ways to perform the required design. SmartPlant Electrical has been designed to create and enter data or entities in a series of stand-alone operations. These operations can be performed in sequences that suit the users needs. Some of the major issues with which SmartPlant Electrical development was concerned were: 1. The very real assumption that current contracts are short in the Electrical Index duration and that accurate and efficient tools are required to maintain the data involved. SmartPlant Electrical Basic User’s Training Guide 11 Introduction 2. The design process is never a ‘one time through’ operation and that changes do occur at any point during the life cycle of the design process. 3. SmartPlant Electrical users need a mechanism whereby they can set up ‘default’ information once and re-use it during the course of the project and in future projects as well. Smart Plant Electrical Modules EI – Electrical Index The Electrical Index is the module where you create and store project-specific equipment and data. Logging into a SmartPlant Electrical project or plant will grant you accessing your tags and relations as per your granted access rights set by your Administrator. The Electrical Index will present the tags that belong to the entire plant or specifically the ones of the lowest plant group (for example, Unit), based on your settings. To view all plant items, on the View menu, select the option Show Items of All Plant Groups (when selected, a check mark appears beside the option as shown), otherwise, to see only those items that belong to the current unit, deselect this option. EE – Electrical Engineer The Electrical Engineer is the module where graphical representations of Equipment and Associations are stored. RDE – Reference Data Explorer The RDE is the module where you create and store reference (or generic) equipment and data. This equipment and data can later be used as seed data to populate projectspecific electrical equipment in the Electrical Index. The more that is invested in properly preparing the ‘generic data’ or ‘defaults’ the greater the savings will be during the course of the current project and on future projects. 12 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment Generators and Power Sources Power sources include generators, battery banks, and offsite power supplies. Create a Project Generator Use the following procedure to create a new project generator ‘G-1’. 1. In the Electrical Index, click Electrical Equipment > Generators. 2. Right-click and on the shortcut menu, click New Generator. 3. Right-click the generator, and on the shortcut menu, click Rename. 4. On the Item Tag dialog box, rename the generator to G-1. • Tip To display the Item Tag dialog box each time you create a new item, click File > Preferences and on the Preferences dialog box, under Open after creating or duplicating an item, click Item Tag dialog box. Duplicate an Item Use the following procedure to duplicate Generator G-1. SmartPlant Electrical Basic User’s Training Guide 13 Electrical Equipment 1. In the Electrical Index, right-click G-1. 2. On the shortcut menu, click Duplicate. 3. On the Item Tag dialog box, type G-2. Delete an Item Use the following procedure to delete Generator G-2. 1. In the Electrical Index, right-click G-2. 2. On the shortcut menu, click Delete. 3. On the Confirm Item Delete prompt, click Yes. Create Electrical Items in Reference Data Explorer You create reference items in the Reference Data Explorer (RDE). You use these items as templates for your SmartPlant Electrical items in the Electrical Index (which contains the project specific items). 1. In the Reference Data Explorer, click Electrical Equipment > Generators. 2. Right-click and on the shortcut menu, click New Generator. 3. Right-click the generator, and on the shortcut menu, click Rename. 4. On the Item Tag dialog box, rename the generator to G-1. 5. In the RDE, select generator G-1. 6. Drag G-1 onto the Generators folders in the Electrical Index. • Tip A sign appears when the dragged cursor is over the Generators folder in the Electrical Index. 14 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment 7. Release the mouse to create the generator. 8. Rename the generator to G-2. Loads Loads include motors, heaters, heat traces, capacitors, harmonic filters, resistors, lighting fixtures, socket outlet, welding outlet, other electrical equipment. Create Motors Use the following procedure to create a typical motor ‘M=10hp’ and from it create project motors. 1. In the Reference Data Explorer, click Electrical Equipment > Motors. 2. Right-click and on the shortcut menu, click New Motor. 3. Right-click the motor, and on the shortcut menu, click Rename. 4. On the Item Tag dialog box, rename the motor to M=10hp . 5. Drag motor M=10hp from the Reference Data Explorer to the Electrical Index. 6. In the Electrical Index, rename the new project motor to M-1. 7. Create another 2 project motors by duplicating M-1 in the Electrical Index, and name the new motors M-2 and M-3. SmartPlant Electrical Basic User’s Training Guide 15 Electrical Equipment 8. Create new motor with heater M-4 and identify motors with space heaters from those without space heaters. Converting Equipment Create a Transformer 1. In the Reference Data Explorer, click Electrical Equipment > Converting Equipment > Transformers. 2. Right-click and add New 2-winding Transformer. 3. Rename it to T-1. 4. Drag T-1 from the Reference Data Explorer to the Electrical Index, and create project transformer T-1 (name the secondary ‘out’). 16 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment Common Features in Smart Plant Electrical • Find finding an item that matches certain criteria. • Refresh windows refresh. • Views • Buttons modifying the lower pane views. creating a shortcut button to an item. Find item - find item based on name or property. SmartPlant Electrical Basic User’s Training Guide 17 Electrical Equipment View – List view pane. Buttons - Creating an item shortcut button. Select an Item. Select Add Button 18 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment To remove a button, select the button you want to remove, and select Remove Button. Properties Window (Property Grid) The property grid window contains all the properties related to the particular entities. Sorting by category versus alpha-numeric sorting Types of Properties: • Char SmartPlant Electrical Basic User’s Training Guide 19 Electrical Equipment Units of Measurement • The ‘Units of Measurement’ select lists are different from other select lists. The user cannot modify the values because they have associated conversions and calculations. • When the user selects one of these fields, such as 0.0 hp, 0.0 hp will appear in the window and the user can then type in the required value. • The default unit of measure for a particular property is set in the Data Dictionary. • Calculated Properties 20 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment • Reference Properties Property that points to a path, such as the symbol name that contains the path to a symbol used in the SLD • Select Lists All select lists are not fully customizable by the users, but users are allowed a large degree of latitude in the ability to modify the lists to according to requirements: The user will not be able to delete any value from a populated select list The user will be able to hide any value (or prevent it from appearing when the select list is opened during operation). SmartPlant Electrical Basic User’s Training Guide 21 Electrical Equipment The user will be able to rename any value (for example, to another language). The user will be able to create additional values in any select list. The user must have access to the Data Dictionary to customize the select lists. Some of this access will be determined by whether the user is logged in as an administrator or as a user and/or if the user has been granted access (more on this later). Thee are also some differences associated with ‘Unit of Measurement’ select lists. The Select Set Apply changes to set of Items Note A Select Set is a temporary set and will not be saved after user moves to another action. 1. Select the Motor folder in the Electrical Index or the Reference Data Explorer. You will see all the motors listed in the bottom pane. 2. Select the required motors from list view pane. 3. In the Properties grid window pick the Select Set. Note: all of the motors that were picked in the bottom pane are also listed in the properties screen. 22 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment Whatever change is made to one property (with Select Set selected) it will apply to all items that are included in the Select Set. When a select set is chosen, a value will appear only if all the items share the same value. Item counter in the Electrical Index or the Reference Data Explorer The counter of the selected items exists in the bottom left part of the SmartPlant Electrical window.The counter displays when highlighting a folder Electrical Loads (Consumers) Entering engineering values using the Common Properties entry form. SmartPlant Electrical Basic User’s Training Guide 23 Electrical Equipment Note: Rated power property, varies and depend on the type of electrical equipment. For all type of equipment it has units of measure type of property, while for Motors it is a select list. Motor Form In the Electrical Index, select M-1 that you already created. Press Ctrl + F2 to invoke the Electrical Motor Common Properties form. General Tab Entering general data like description, manufacturer, model, motor type and frame size. Data quality field enables you to qualify the status of the data of this motor. Conformity to Standard, allows you to specify the standard for electrical calculations when you associate a power cable with the motor. Load Data Tab Dependencies and workflow, fill in the required fields to see it in work. The fields that are marked with asterisks (*) are required fields. If you do not enter data for these fields, the software does not calculate certain important values. To obtain the demand factor, on the Load Data tab, you should fill in values for Rated power and Brake power (consistency of units is not mandatory, you may enter mixed hp and kW values). The software also validates that the brake power does not exceed the rated power value. Select a value for Rated voltage and let the system calculate the value for Full load current (this property appears on the Electrical Data tab). 24 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment To obtain the synchronous speed, you should enter values for the Frequency, Poles, and Supply properties. The software validates that the asynchronous speed never exceeds the synchronous speed. Select an operating mode to enter the coincidence factor of that motor To get the Power factor and Efficiency values at demand you need to enter the Electrical Index values at 50%, 75%, and 100% of operation. We will see later that thee is a better way to populate these values using lookup tables. Electrical Data tab calculations behind these calculated fields. Once you have entered all the previous values on the Load Data tab the software calculates all three vectors of the electrical consumption from the bus that feeds this motor. The full load current can be the Electrical Index the calculated or entered manually, depending on the Override FLA Calculation flag. If it is set to Calculate, the values are calculated using the rated power, power factor at 100%, rated voltage, number of phases and according to whether the supply is AC or DC. Observe the relation between the FLA, LRC, and the Electrical Index ratio. SmartPlant Electrical Basic User’s Training Guide 25 Electrical Equipment Controls & Signals Tab Provides optional information for control stations that control the motor operation, and controls and signals for the motor. 26 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment Instruments Tab Displays instruments that monitor and control the motor operation. Feeder Data Tab Enables you to view and assign a feeder (provided an association to a feeder circuit does not yet exist). Once an association is made, the only way of dissociating a motor from its feeder circuit is in the Electrical Engineer. On this tab, you can: Pre assign the Motor to a PDB and to a bus without actually creating feeder circuits Assign and Create feeder circuits on the fly, based on the last applied typical circuit Once the Motor is assigned to a Feeder circuit you will see the actual components in that circuit shown in the Internals grid. Feeder equipment, displays the name of the equipment other than feeders that the load is fed from. Such equipment can be a transformer's secondary, variable speed drive and so forth. SmartPlant Electrical Basic User’s Training Guide 27 Electrical Equipment The last tab is the Alternate Feeder tab, showing the second power source that may be feeding this motor, in case thee is such: Static Loads, Heater Equipment Form In this session you learn about all the various properties that may be edited or viewed for Static loads, using the forms and the Electrical Index behavior under various circumstances. The corresponding editing functionality using property grid will be mentioned The function of the various tabs is very much the same as for the motor except for few minor differences due to the fact that static loads are not rotating, therefore properties such as brake power, LRC power factor, synchronous and asynchronous speeds, and so forth, do not apply. 28 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment Heater Common Properties General Tab Very similar to motors Load Data Tab - calculated fields Notes: Rated power for these types of loads is not a select list but rather a property with engineering units. Each type of static load has its own category of units of measure. For example, heaters have Power, whereas capacitors and harmonic filters have Reactive power, etc. The demand factor, power factor, and efficiency at demand are manual entries rather than calculated values. Create new heater H-1. Electrical Data tab Calculations behind these calculated fields. The calculated electrical properties are very similar to those for motors. SmartPlant Electrical Basic User’s Training Guide 29 Electrical Equipment Transformers and Other Types of Converting Equipment Create new transformer T-1 (New 2-Winding Transformer), and T-2 (New 3-Winding transformer). Transformer Common Properties General Tab 30 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment Electrical Data tab Full load current is also a calculated property. Nominal current for the secondary windings is not a calculated value. SmartPlant Electrical Basic User’s Training Guide 31 Electrical Equipment Lab 1 1.1 Typical Electrical Equipment Create the following typical items in Reference Data Explorer: Typical Motors: 1. NEMA 1 MTR – 1 HP Motor Rated Power = 1 hp Rated Voltage = 460V 2. NEMA 2 MTR – 15 HP Motor Rated Power = 15 hp Rated Voltage = 460V 3. REFMTR-1HP 4. REFMTR-15HP (by duplicate typical motor NEMA 1 MTR – 1 HP) (by duplicate typical motor NEMA 2 MTR – 15 HP) Typical Motor with Heater: 5. NEMA 1 MTR w/ HTR – 1HP/1KW Motor Rated Power = 1 hp Rated Voltage = 460V 1 KW MTRHTR (for the motor’s heater item tag) Rated Power = 1 KW Rated Voltage = 460V Typical Heater: 6. HTR-REF-1KW Rated Power = 1 KW Rated Voltage = 460V 1.2 Project Electrical Equipment Create the following items in Electrical Index: Motors: 1. Mtr-100-1 (copy from typical NEMA 1 MTR – 1 HP) 2. Mtr-100-2 (copy from typical NEMA 2 MTR – 15 HP) *3.M-100 Motor Rated power =1 hp Brake Power =0.75 hp Rated Voltage = 220 V Supply=AC Number of phases=3 Frequency=60Hz Number of poles=4 Operation Mode=continuous (X=1.0) *4. M-101 32 SmartPlant Electrical Basic User’s Training Guide Electrical Equipment Motor Rated power =10 hp Brake Power =6.8 hp Rated Voltage = 460 V Supply=AC Number of phases=3 Frequency=60Hz Number of poles=4 Operation Mode=continuous (X=1.0) *5. M-102 Motor Rated power =100 hp Brake Power =80 hp Rated Voltage = 460 V Supply=AC Number of phases=3 Frequency=60Hz Number of poles=4 Operation Mode=continuous (X=1.0) *6. M-103 Motor Rated power =10 hp Brake Power =6.8 hp Rated Voltage = 460 V Supply=AC Number of phases=3 Frequency=60Hz Number of poles=4 Operation Mode=continuous (X=1.0) Motor with Heater: 7. Mtr/H-100-1 (copy from typical NEMA 1 MTR w/HTR – 1HP/1KW) MHtr-100-1 (for the motor’s heater item tag) Heater: 8.Htr-100-1 *9. (copy from typical HTR-REF-1kw) H-102 Motor Rated power =100 kW Rated Voltage = 380 V Supply=AC Number of phases=3 Frequency=60Hz Operation Mode=intermittent (Y=0.5) Demand Factor =1 Power Factor =0.9 (100% =0.9,At demand=0.9) Efficiency =0.9 (100%=0.9,At demand =0.9) Generator: *10. G-001 Rated Apparent Power = 1 MVA Rated Voltage = 3300 V Supply=AC Number of phases=3 SmartPlant Electrical Basic User’s Training Guide 33 Electrical Equipment Frequency=60Hz Transformer * T-001 3 winding transformer, primary T-001, secondary X,Y Rated power= 1 MVA Rated voltage of the primary = 3300v Supply=AC Number of phases=3 Frequency=60Hz Rated voltage of the secondary = 460/400v 34 SmartPlant Electrical Basic User’s Training Guide Tabular Editor Create a Table 1.To create a new tabular editor, select Window > New > Table. Select an item type, filter (optional), and a layout. Click OK. to open the document of the tabular editor. Note: When you create a Tabular Editor view for abstract item types such as loads or converting electrical equipment, as opposed to specific item types such as motors or transformers, the software displays all the common properties for these item types in the Tabular Editor. With loads, for example motors and heaters both appear, but the software cannot display the Electrical Index specific properties in one common Tabular Editor view. However, when you select items of the same specific type, all of the properties appear in the Properties window. Scope of items: Note that the Tabular Editor will show the Tags as per your settings; the Electrical Index the All items of the plant or only those of the current unit. Create and use layout in tabular editor From Table Properties dialog box SmartPlant Electrical Basic User’s Training Guide 35 Tabular Editor Select item type, and select advanced. In the Advanced Table Properties dialog box, select layout. 36 SmartPlant Electrical Basic User’s Training Guide Tabular Editor To create a new layout, type its name, and add properties as required. Notice that the edit section let you to sort the items. Click Save to save your new layout. Click OK, and return to the Table Properties. Click OK to open the Tabular Editor view with the new layout. SmartPlant Electrical Basic User’s Training Guide 37 Tabular Editor Brief, Bulk, and Brief/Bulk layouts From the Usage select list, you can select from 4 choices: a blank value, Brief, Bulk or Brief/Bulk. The 4 distinctions have to do with how Properties are displayed and used in the Property Grid Window. -Only one brief layout can be active at a time for a given item type. -Only one bulk layout can be active at a time for a given item type. -You can duplicate a view by selecting one of the available views, modifying its name and properties, and saving it under the new name. Brief - selecting the brief icon displays only the properties defined by the brief layout 38 SmartPlant Electrical Basic User’s Training Guide Tabular Editor Copy Bulk Properties - to copy properties from layout that set as bulk. Paste Bulk Properties - pasting bulk properties into another tag or a selected set of tags. SmartPlant Electrical Basic User’s Training Guide 39 Tabular Editor Using the Copy feature to copy a table to an external file Using filters through the Tabular Editor From the Table Properties dialog box, select Advanced to open the Advanced Table Properties. There are 2 types of filters you can create. 1.“On the fly filter” 40 SmartPlant Electrical Basic User’s Training Guide Tabular Editor 2. “Base Filter” created through Filter Manager. This filter can be saved and used in many places. To create the base filter through filter manager, select the Browser button. In the Select filter dialog box select the folder you want to locate the new filter. Note: Filter created under Plant folders available to all users, filter created under my folders available only to creator. SmartPlant Electrical Basic User’s Training Guide 41 Tabular Editor Select New to create the new Base filter. When prompt to select simple/compound filter), select the simple filter. (A compound filter consists of more than one simple filter). Enter a name for the new filter (Motor 1 hp) 42 SmartPlant Electrical Basic User’s Training Guide Tabular Editor SmartPlant Electrical Basic User’s Training Guide 43 Tabular Editor The Tabular Editor can be also used in a more advanced mode by editing the required items directly. Create new item. 1.Copy and paste data from one item to another. Copy and paste data from one group of cells to another similar set of cells. Sorting. Filtering. Deleting an item. Duplicating an item. Rename item. Open the common properties form. Finding items in other opened windows Copy and Paste Open the tabular editor with motor as item type, and motor list as layout (shipped layout). Select Manufacturer and Brake Power of motor M-1 (to do this, click the Manufacturer cell and move the mouse to the right to also include the Brake Power cell). Right-click, and on the shortcut menu, click Copy. 44 SmartPlant Electrical Basic User’s Training Guide Tabular Editor Move to Motor M-2 and select the same two properties (click Manufacturer and select the 2 adjacent cells) Right-click, and on the shortcut menu, click Paste. Observe that you have copied these two properties from M-1 to M-2. To copy a complete tag (without of course copying the value of the Item Tag property), select the required tag by clicking on the left side sequence number of that tag, right-click to display the shortcut menu, click Copy, and then select another tag and click Paste on the shortcut menu. To copy a complete record to a group of records, copy the required tag as before, then select the required target tags using the mouse + Ctrl key, and then right-click and paste. Auto Filter Freeze Panes It is possible to freeze panes by selecting a column, then selecting the Freeze panes option in the popup menu. As a result, all columns left to the selected one .get into freeze status. Find in Index and Engineer SmartPlant Electrical Basic User’s Training Guide 45 Tabular Editor Navigate to a Tag in the Electrical Index or in the Electrical Engineer. Lab 2 2.1 Create Table and view the data Item type: Motor. Layout name: Motor Layout Lab Attributes: Item tag, Description, Motor Rated Power, Rated Voltage Usage: Brief/Bulk. 2.2 Create and edit data from tabular editor. 1. Create from tabular editor new motor M-5. From tabular editor set the following values for motor M-5: Motor Rated Power = 3 hp Rated Voltage = 460V. 2. From tabular editor set the following values for motor M-2 and M-3: Motor Rated Power = 10 hp Rated Voltage = 460V. Note: Double click on cell enables the cell for editing. 46 SmartPlant Electrical Basic User’s Training Guide Tabular Editor 2.3 View and copy data using the Brief/Bulk usage. From Electrical Index do the following actions: 1. Select M-1 and view its properties from property grid. 2. Select Brief Properties button in the property grid and view the change. 3. Select Copy Bulk Properties button. 4. Select M-5 and select the Paste Bulk Properties button in the property grid. Select the common property form of M-5 and view the data. 2.4 Using Filters 1. Create ‘on the fly’ filter for motor to bring only motor with Motor Rated Power = 1hp. 2. Create basic filter for motor to bring only motors with Rated Voltage = 460 V and name the filter, Motor = 460 V SmartPlant Electrical Basic User’s Training Guide 47 Power Distribution Board PDB’s and the related internal associated items play a major role in the design of an electrical distribution network. A PDB usually is a confined enclosure that contains the necessary electrical internal equipment that will accept and distribute power from power sources to loads or other secondary distribution PDB’s. While all types of PDB’s behave the same (SmartPlant Electrical wise) thee are different names for these PD’s, based on what load they supply and what function they serve in the electrical network. The following terms are used in a mixed way in the various regions and countries: Switchgear, PDB that supplies power to other lower voltage PDB’s such as MCC’S Load Center is a PDB that distributes power to MCC’s MCC (Motor Control Center) is a PDB that supplies power mainly to motors Switchboard is usually a PDB that delivers power to small loads such as lighting fixtures and low voltage circuit breaker distribution boards PDB’s accept power (current under specific voltage levels) from power sources such as generators, UPS, battery banks, other PDB’s, transformers, etc. PDB’s deliver power (current under specific voltage levels) to loads and to other PDB’s. PDB’s accept power through incomer circuit that are connected to internal physical metal buses (copper or other conducting material) PDB’s deliver power through internal feeder circuits that connect to the internal buses Internal buses of a PDB can supply power to each other (a circuit in a bus is a feeder to another bus). These type of feeder circuits are called bus couplers and they connect to circuits that contain bus risers that receive the power and transfer the power to the bus Create PDB/BUS/CELL/CIRCUIT/INTERNALS PDB - From the Electrical Index select the Power Distribution Boards folder exists under Electrical Equipment, Power Distribution Equipment. SmartPlant Electrical Basic User’s Training Guide 48 Power Distribution Board Right-click and select New Power Distribution Board. BUS - Select the Buses folder exists under PDB-1. Right-click and select New Bus. PDB and BUS in the Reference Data Explorer SmartPlant Electrical Basic User’s Training Guide 49 Power Distribution Board PDB and BUS in the Electrical Index using the Reference Data Explorer PDB. Drag and drop the Reference Data Explorer PDB to the Electrical Index Power Distribution Board folder. CELL - Select the BUS in the Electrical Index. Right-click and select New Cell. Circuits Add circuit to CELL or BUS. Select the CELL or BUS. Right-click and select one of the available circuit types: 50 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board • Incomer circuit – A cable or circuit that supplies power to a power distribution board. • Feeder circuit – A cable or a circuit that distributes power from a distribution board to other equipment. • Coupler circuit – A circuit that connects two buses in a power distribution board for the purpose of creating a bus tie. This circuit belongs to the bus that servers as the power source of the coupled bus in the PDB. • Bus Riser circuit – A circuit that connects two buses in a power distribution board for the purpose of creating a bus tie. This circuit belongs to the bus that servers as the receiver of backup power from the feeder bus in the PDB. Typical circuit in the Reference Data Explorer Select Typical Circuits folder. Right-click and select one of the available circuit type. Disconnect Electrical Equipment These items are the components that are used internally in Power Distribution Boards in buckets and circuits or as stand-alone items. The individual disconnect electrical SmartPlant Electrical Basic User’s Training Guide 51 Power Distribution Board equipment that we create in the Reference Data Explorer can be used in the project by dragging them to the appropriate the Electrical Index folder or dragging them onto typical circuits. Note: Power Distribution internal circuit components are not shown in the individual folders. In the Electrical Index select one of the available type of Disconnect Electrical Equipment. Right-click to add new item. In the Reference Data Explorer select one of the available type of Disconnect Electrical Equipment. Right-click to add new item. Add internals (Disconnect Electrical Equipment) to circuit. Select circuit in the Electrical Index. Right-click and select one of the available internals. 52 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board In the Reference Data Explorer you select typical circuit. Right-click and add one of the available internals. The internal types you can add into typical circuit or project circuit are: Battery Charger, Other Converting Equipment, 2-Winding Transformer, Uninterrupdible Power Supply, Variable Frequency Drive, Contactor, Overload Relay, Disconnect Switch, Circuit Breaker, Fuse, Starter, Other Disconnect Equipment, Current Transformer, Potential Transformer, Ammeter, Voltmeter, Multimeter, Protection Relay. Adding cables to typical circuits and project circuits Considering that the control side of the circuit may have cables that connect from the circuit to a DCS/PLC, there is a way to automate the creation of these cables by adding cables to the typical circuits and from there to the project items. SmartPlant Electrical Basic User’s Training Guide 53 Power Distribution Board Once this is specified, applying the typical circuit on a circuit will create the Project cables as well, with the Electrical Index “to” side associated to the circuit. Instruments Instruments can be created in SmartPlant Electrical and associated later to main equipment, such as motors or generators. To create an instrument, select right mouse click on the Instruments folder: To edit its properties, use the property grid or working through the various tabs of the Common Properties: 54 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Design of PDB Layout – General Arrangement SmartPlant Electrical enables to design the cabinet layout of Power Distribution Boards that have cells defined. The cabinet layout can be viewed, printed and saved as document and deliverable; you can revise it - with both the graphical presentation of the distribution and location of the various cells and also an embedded report of the data for the cells and the loads and circuits that are contained within these cells. The following features are supported: Define the structure of PDB in terms of: · Number of vertical sections (maximum allowable is 30). · Number of horizontal rows (maximum allowable is 15). · Number of compartments (subdivisions). · Position in PDB can be further subdivided (maximum allowable is 4 by 4). · Define the naming conventions for the sections and rows, those will be used for identifying the cells position within the PDB · Drag and drop cells from the Index to layout. · Move cell from one position to another. · Change size of position and cell SmartPlant Electrical Basic User’s Training Guide 55 Power Distribution Board Assign a cell usage in the property grid (In Use, Spare, Spare Place) To open Design PDB Layout select a PDB. Right-click and select Design PDB Layout Change Cell Size Place a cell. Select cell you want to place from the Electrical Index and drag it to the PD Layout. 56 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Issue a report of the PDB Layout with the relevant data of the internal configuration and design. SmartPlant Electrical Basic User’s Training Guide 57 Power Distribution Board The following rules apply on designing a PDB Layout: · Once the number of sections, rows, number of vertical/horizontal compartments have been defined, any attempt to modify these settings will result (after a warning) in a complete cellcompartment reset and un assignment (in case no cell has been assigned no harm will be caused…) · The only exception is that the user is able to add sections to the right side of the PDB (by increasing the number of section in the property grid by the use of the ellipsis…) · The origin point of each and every compartment is its left upper point. This means that any change of compartment size is referenced to that point. · A compartment may be enlarged to its right or to its bottom only (a left most compartment in a vertical section can only be enlarged to its right or to any free space available down). · A compartment cannot be enlarged to a part of an adjacent compartment; you change its size to occupy the entire right side adjacent compartment size. · A compartment cannot exceed the boundaries of a section · A compartment can exceed the boundaries of a row. 58 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Lab 3 Create PDB’s *3.1 Create Switchgear SW-300 1.Create in the Electrical Index, Switchgear, SW-300. From property grid set its Electrical Equipment Type to Switchgear. 2.Under SW-300, Create bus, Bus A-3.3KV/SW-300 From property grid set the bus rated voltage to 3.3 kV. 3.Under Bus, A-3.3KV/SW-300, create one cell for incomer circuit, SW-300 Main Utility Inlet And two cells for the feeder circuits, MCC-201/2 Bus A Feeder, and MCC-201/2 Bus A Spare Feeder 4.Under the incomer cell, create incomer circuit, SW-300 Incomer 5.Under MCC-201/2 Bus A Feeder cell, create feeder circuit, MCC-201/2 Feeder And under MCC-201/2 Bus A Spare Feeder cell, create feeder circuit, MCC-201/2 Spare Feeder 6.Copy from the Reference Data Explorer to the Electrical Index (drag & drop), the typical circuit, Switchgear Incomer, to circuit SW-300 Incomer 7.Copy from the Reference Data Explorer the Electrical Index (drag & drop), the typical circuit, MCC Feeder, to circuits MCC-201/2 Feeder and MCC-201/2 Spare Feeder 8.Verify you have all the required circuit internals according to the ‘Demo Training SLD’. * 3.2 Create Motor Control Center, MCC-201 and MCC-202 1.Create in the Electrical Index Motor Control Center, MCC-201. From property grid set its Electrical Equipment Type to Motor Control Center. 2.Under MCC-201 create 2 buses, MCC-201/Bus A- 460 V, and MCC-201/Bus B460 V From property grid set rated voltage to 460V, and Number of phases to 3. 3.Under bus, MCC-201/Bus A- 460 V, create the following circuits: SmartPlant Electrical Basic User’s Training Guide 59 Power Distribution Board Incomer, MCC-201 Bus A Incomer Feeder, M-100 Feeder Feeder, M-101 Feeder Feeder, Spare Motor Feeder Coupler, MCC-201 Bus A/B Coupler 4.Under bus, MCC-201/Bus B- 460 V, create the following circuits: Incomer, MCC-201 Bus B Incomer Feeder, M-102 Feeder Feeder, M-103 Feeder Feeder, H-102 Feeder Bus Riser, MCC-201 Bus A/B Bus Riser 5.Copy from the Reference Data Explorer the Electrical Index (drag & drop): Typical circuit MCC Incomer, to circuit MCC-201 Bus A Incomer Typical circuit Motor Feeder <1hp, to circuit M-100 Feeder Typical circuit Motor Feeder<10hp, to circuit M-101 Feeder Typical circuit Bus Coupler, to circuit MCC-201 Bus A/B Coupler Typical circuit Bus Riser, to circuit MCC-201 Bus A/B Bus Riser Typical circuit MCC Incomer, to circuit MCC-201 Bus B Incomer Typical circuit Motor Feeder<100hp, to circuit M-102 Feeder Typical circuit Motor Feeder<10hp, to circuit M-103 Feeder Typical circuit Heater Feeder, to circuit H-102 Feeder 6.Verify you have all the required circuit internals according to the ‘Demo Training SLD’. 7.Duplicate MCC-201 and name the new MCC, MCC-202 8. Rename MCC-202’s buses and circuits according to ‘Demo Training SLD’. *3.2 Design PDB Layout for SW-300 60 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board 1. Select SW-300 and from properties grid set the Numbers of Columns and Number of Rows to 5. And set Compartments in Section, and Compartments in Row to 1. 2. Right-click on SW-300 and on the shortcut menu, select Design PDB Layout. View the Default design and make changes in the layout to exercise its options (Number of rows/sections, compartments in rows/sections, naming conventions). 3. Allocating SW-300’s cells into specific positions in to layout. 4. Generate Report. The system opens Excel with the first page showing the general layout of SW-300 and the second page tabulating the cells and internal equipment and any load assigned to the relevant circuits. SmartPlant Electrical Basic User’s Training Guide 61 Power Distribution Board Wiring Equipment Panels Cabinets Serves as placeholder for panels that will be retrieved as loads. Cabinets have Common Properties form with 3 tabs, General tab, Electrical data and Feeder tab. In the electrical tab the user will be able to define its power consumption in Watts or Kilowatts and the system will calculate the current as for any other load. Cabinets may be connected to feeder circuits and buses as any other load, the Electrical Index the by dragging them over to buses or feeder circuits or from the Feeder data tab in the Common properties form. 62 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board You create cabinets in the Electrical Index or EE. Control Stations Local or remote panels that contain the control elements (start-stop push buttons) activated manually by the person operating the plant. You can create such control stations with or without associated cables. Control stations can be created in one of 3 ways: • Manually, by select Control Station folder and select New Control Station • Automatically, as part of the creation process initiated from the Apply Profile option or Apply Control station tab of the Apply Options. • Copy from the Reference Data Explorer. SmartPlant Electrical Basic User’s Training Guide 63 Power Distribution Board A control station can be associated to a project cable (cable category should be control, ground or instrument), and/or to a load. A control station may have more than one cable, but it can have one load associated only. Once a cable is associated to a control station, the control station becomes the “to” side reference of that cable. When the creation of the control station is a result of an automated process as described above, the association is created as part of the automation process, both to the cable and to the load. In case the control station is created manually, the user is responsible for these associations. Local Panels and Junction Boxes Local Panel 64 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Cabinets containing circuit, equipment, and wiring items, used for example, to provide switching or isolation close to a motor. Junction Boxes Cabinets used to connect wires that run between various items of electrical equipment. Note: In contrast to Power Distribution Boards (PDBs), local panels and junction boxes are much smaller in size and do not contain busbars. Cables Smart Plant Electrical specifies the following cable categories according to the purpose of the cable: Power, control, grounding, and instrument. The software supports compliance with the strict regulations governing cable definitions by using standard reference cables as a basis for all the cables that you create in your project. Reference cables contain technical cable data such as voltage rating, ampacity, resistivity, cable material, and data relating to the construction of the cable. For this reason, you must initially create SmartPlant Electrical Basic User’s Training Guide 65 Power Distribution Board all your reference cables in the Reference Data Explorer. The software allows you to organize your reference cables in families known as cable specifications. When you select a reference cable to use as a basis for your project cable, you must select the appropriate cable category and cable specification for the reference cable. Also, when you size project cables, the software looks for the appropriate reference cable based on a particular cable specification and conductor arrangement. Power Cable Category Reference Power Cable Create new reference power cable by select the power cable folder in the Reference Data Explorer, right-click and add new power cable. Edit the cable properties on the Reference Cable Common Properties dialog box according to the available catalog information, including conductor arrangement size material and electrical cable data. 66 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Project Power Cable Project cables based on existing reference cables. Create new project cable by select the power cable folder in the Electrical Index, right-click to add new power cable. SmartPlant Electrical Basic User’s Training Guide 67 Power Distribution Board Open the cable common properties form, and select the cable specification and the reference cable. Selecting the reference cable populate the values from the selected catalog (the Reference Data Explorer) cable. 68 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board SmartPlant Electrical Basic User’s Training Guide 69 Power Distribution Board 70 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Note: 1. You can leave the default ‘Non Sized Cable’ for reference cable, fill in the values for cable construction manually, and select a reference cable later. 2. Asterisk indicates field required for cable sizing calculation. Control Cables Cables in this category do not need sizing calculation, or to have electrical properties such as ampacity and resistance values. Reference Control Cable Create new reference control cable by select the control cable folder in the Reference Data Explorer, right-click and add new control cable. Edit the cable properties on the Reference Cable Common Properties dialog box according to the available catalog information, including conductor arrangement size material and electrical cable data. SmartPlant Electrical Basic User’s Training Guide 71 Power Distribution Board Project Control Cable Project cables based on existing reference cables. Create new project cable by select the control cable folder in the Electrical Index, right-click to add new control cable. 72 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Open the cable common properties form and select the cable specification and the reference cable. Selecting the reference cable populate the values from the selected catalog (the Reference Data Explorer) cable. SmartPlant Electrical Basic User’s Training Guide 73 Power Distribution Board 74 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board SmartPlant Electrical Basic User’s Training Guide 75 Power Distribution Board Grounding Cables Grounding cables have only one conductor arrangement, which is the single conductor cable. The other parameters and behavior is similar to control cables. Reference Grounding Cable Project Grounding Cable 76 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board SmartPlant Electrical Basic User’s Training Guide 77 Power Distribution Board 78 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Instrument Cables Cables with concept of cable set (pair, triad, etc) and shields. Reference Instrument Cable SmartPlant Electrical Basic User’s Training Guide 79 Power Distribution Board Project Instrument Cable 80 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board SmartPlant Electrical Basic User’s Training Guide 81 Power Distribution Board 82 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Parallel Cables Parallel cables are groups of cables that were created as a result of the cable sizing or added or converted into parallels cables and as such they behave as a group for all senses and operations. The number of Parallel cables (or cores per phase) is indicated in the User Interface: SmartPlant Electrical Basic User’s Training Guide 83 Power Distribution Board Busways A busway is a brass or other metallic bar, like in the PDB, used to connect between two item tags, on cases that regular cables cannot do the job; the Electrical Index the due to the high required current or for other reason. A bus way functionality is similar to the one of the power cable without the sizing capability and with no Common properties form. 84 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Signals The system allows creation of reference signals. Creating a signal under a specific item is enabled for loads, converting equipment, typical circuits battery banks and generators. I/O Sets These typical I/O sets may be used in conjunction with reference control stations and typical circuits. SmartPlant Electrical Basic User’s Training Guide 85 Power Distribution Board Reference I/O sets can be dragged from the Reference Data Explorer to the Index for all the valid items: Loads, Converting equipment, Generators, Battery Banks, circuit, disconnect equipment, control stations. Lab 4 4.1 Reference Panels Create the following reference panels in the Reference Data Explorer Reference Cabinet 1. REF-CAB-1 Reference Control Station 2. REF-CS-1 Associate to the control station REF-CS-1, the reference cable 3/C- 1 mm2- (Control), and the typical I/O set DI/DO 86 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board Reference Local Panel 3. REF-LP-1 Add to the local panel REF-LP-1, new circuit LP-1-CKT-1 with new disconnect switch, DS-1 Reference Junction Box 4. REF-JB-1 Add to the local panel REF-JB-1, new circuit JB-1-CKT-1 with new disconnect switch, DS-1 4.2 Reference Cable Create the following reference cables in the Reference Data Explorer Reference Power Cable 5. 3+1/C - 0.75 mm^2 - (Power / mm^2) Reference Control Cable 6. 3/C - 0.75 mm^2 - (Control) SmartPlant Electrical Basic User’s Training Guide 87 Power Distribution Board Reference Grounding Cable 7. 1/C - 0.75 mm^2 - (Ground) Reference Instrumentation Cable 8. 3 Pair w/Shield 0.75 mm2- (Instrumentation) 88 SmartPlant Electrical Basic User’s Training Guide Power Distribution Board 4.3 Project Panels Create the following project panels in the Electrical Index Project Cabinet 9. CAB-P-1 (Using the reference cabinet REF-CAB-1) Project Control Station 10. CS-P-1 (Using the reference control station REF-CS-1) Project Local Panel 11. LC-P-1 (Using the reference local panel REF-LP-1) Project Junction Box 12. JB-P-1 (Using the reference junction box REF-JB-1) 4.4 Project Cables Create the following project cables in Electrical Index Project Power Cable 13. C-PWR-P-1 (Using the reference cable 3+1/C - 0.75 mm^2 - (Power / mm^2)) *14. C-Main Utility Supply (Using the reference cable 3/C - 120 mm^2 - (Power / mm^2)) *15. C-T-001/P (Using the reference cable 3/C - 120 mm^2 - (Power / mm^2)) *16. C-T-001/X (Using the reference cable 3/C - 120 mm^2 - (Power / mm^2)) *17. C-T-001/Y (Using the reference cable 3/C - 120 mm^2 - (Power / mm^2)) SmartPlant Electrical Basic User’s Training Guide 89 Power Distribution Board Project Control Cable 18. C-CTL-P-1 (Using the reference cable 3/C- 0.75 mm^2- (Control)) Project Grounding Cable 19. C-GND-P-1 (Using the reference cable 1/C - 0.75 mm^2 - (Ground)) Project Instrumentation Cable 20. C-INS-P-1 (Using the reference cable 3 Pair w/Shield 0.75 mm2- (Instrumentation)) 90 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations This part deals with advanced procedures and operations that will save you time, enable the reuse of default engineering data and minimize the errors due to manual data entry. Look-Up Tables (LUT) SmartPlant Electrical Basic User’s Training Guide 91 Propagating Default Data and Associations Create LUT From the Reference Data Explorer select Look Up Tables hierarchy folder, select motors (or other equipment type) Right-click to create new lookup table name it LUT-1 Select the LUT-1, right-click and select common properties You can have more than one LUT for each equipment item type. The default look up table check box set the default LUT for an equipment item type. Only one default LUT is allowed for each Equipment Item type. Select the Structure tab. In the edit section you select the properties you would like to include in your LUT. From the Property list, find the property that contains the info that you need In caption, enter the name of the heading you would like to see. From Input/Output, select Input to specify a key property, or select Output to specify none key property. Note: It is very important that you pay particular attention to the Input/Output option. When this look-up table is applied to an item, the program looks for an exact match of all the properties that are specified as key fields. Set True value in Overwrite option to overwrite whatever value is already in the property. Set False will only write to empty property. Set properties and click the Add button. The definition window reflects the properties you have selected. When you have selected several properties, you can arrange the Electrical Index order by using the Up and Down buttons. The Remove button removes the highlighted property. Select the Data tab. Select the arrow to the right of the property and select the appropriate values. When you finish Click OK. Apply Options The Apply Options command allows creating and populating project tags with massive default equipment and the Electrical Index data. 92 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations The following options are available: Equipment Profile Typical Circuit Control Station Lookup Tables Typical Schematic Typical I/O Set When applying any of these options, the user has to select the enable check box found in the dialog. Only one is allowed at a time (checking the flag on one tab resets any previously checked flag).You can define the applied set of tags the Electrical Index the in the lower pane of the Electrical Index window by making multiple selections or in the Tabular Editor by highlighting a subset of tags from the table. Apply Lookup Tables Applying look up tables may result in overwriting project data. One should be aware of this. The right timing on whether and when to commit this operation is an engineering decision and would be based on your project state and your workflow. You should make sure that the tags that have been selected for this operation have the key fields populated with data that will be recognized by your look up tables, otherwise, data will not be populated. SmartPlant Electrical Basic User’s Training Guide 93 Propagating Default Data and Associations Apply Typical Circuit The purpose of this feature is to have a powerful way of the Electrical Index the to create new circuits and internals or to replace existing circuits or internals. Applying typical circuit on item will not create the internal components if the item is not yet associated with a circuit. In this case, only a reference to the typical circuit is maintained. You can verify which typical circuit is assigned to a item by opening the “Feeder Data” tab of the item. Circuit internals (also, typical circuit internals) must have a unique sequence (order) property, which determine the Electrical Index power path in the Electrical Engineer. Applying a typical circuit on an item must preserve the electrical relations (if existed before) between the last internal component in the circuit and any other “external” object that was associated before (usually this would be a cable). Applying typical circuits is available upon selecting single or multiple items. The following are the various options for applying the typical circuit work correctly on the selected set or multiple items you have highlighted. All Items Applies the profile to all the selected items. Items with no typical circuit Applies the profile only to items without an existing profile. Use this option to add a profile only to new items among the items that you selected. Items with a different typical circuit from the selection Changes the profile of the selected items to the current profile. Use this option to add a profile to items with a modified profile definition. Items with the same profile as the selection Updates an existing profile for the selected items. 94 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations Clear last applied typical circuit makes it possible to clear pre associated typical circuits. The actual project items are created as per the typical circuit (you need to associate the load with a PDB – Bus and Cell in order to create them) When applying a typical circuit on loads that have electrical associations, associations are kept. Guidelines and rules: 1. When assigning typical circuits, the system checks and prompts in case of discrepancy between the reference typical of the load and the circuit we are trying to associate it to. In case of a batch, the user is the decision-maker and he has the option to choose the scenario. No prompt will be issued in the batch apply. The “Apply” will govern and not the circuit.(still, the rules will govern- in case thee are some motors that were not applied a “non all items has been successfully committed” message will be issued) 2. Associating a motor to a circuit that has no internals will result in creating the actual internals if thee is a reference in the motor. If not, it will not generate anything. Internals will be created once the profile is applied on the load. The form of the load/motor will be updated to show this typical circuit. 3. Trying to associate a motor with a typical circuit on a circuit (the Electrical Index the by the drag and drop or applying a profile) that has different type of typical defined within it, will be preceded with a message: "Load and circuit internals are different- do you wish do override circuit internals? “Yes” or “Cancel” will tell the system how to proceed. If yes, the system will replace, as in the apply profile the internals of that circuit. Reapplying a Typical Circuit Typical circuits will replace the existing internal circuits and the Electrical Index components with the Reference Data Explorer components that constitute the typical circuit. Any existing electrical relations and association will be kept and preserved (so the Electrical Engineer will not be affected). It will be up to the designer to make sure that what he is doing is right. Apply Control Station Applying control stations on loads will add new control stations and the Electrical Index cables or replace existing control stations (and the Electrical Index cables) associated with the loads. The control stations associated with a load can be seen in the “Control & Signals” tab of the load. This identifies the project control stations associated with the load. You can identify to which load the control station belongs to and what are the cables that are associated to it by opening the control station property dialog. SmartPlant Electrical Basic User’s Training Guide 95 Propagating Default Data and Associations Note: When reapplying control stations you should expect: Existing control stations and the Electrical Index cables should be replaced or added according to the checked options (old control stations and the Electrical Index cables deleted) Cable associations, if existed, should REMAIN (we are talking of control cables associated to control station- any new stations will be new and any replacements will result in replacing the cables + stations Control stations and the Electrical Index cables will be replaced by the new set of control stations and the Electrical Index cables. Any associations and relations of these items will remain as before, the To and From relations of the cables will be transferred to the new control stations and the cables. Any additional control station cable will have its To side associated to the control station and its From side will be not assigned. Apply Typical Schematic This option is used when you need to specify a typical schematic or to modify the associated typical schematics of a group of loads The user may associate typical schematics also to loads, converting equipment, circuits, disconnect electrical equipment, generators, battery banks and buses. 96 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations All items - Applies the typical schematic to all the selected items. Items with no typical schematic - Applies the typical schematic only to items without an existing typical schematic. Use this option to add a typical schematic only to new loads among the loads that you selected. Items with a different typical schematic from the selection - Changes the typical schematic of the selected items to the current typical schematic. Use this option to add a typical schematic to items with a modified typical schematic definition. Apply Typical I/O Set Sets options for associating typical I/O sets to items in the Electrical Index. SmartPlant Electrical Basic User’s Training Guide 97 Propagating Default Data and Associations Enable typical I/O set Select this check box to apply a typical I/O set. This check box is used for security to prevent you from applying a typical I/O set in error. Select typical I/O set Clear last applied typical I/O set Clears the typical I/O set that you last applied. Select this option if you do not want to apply any typical I/O set to the item. Typical I/O set Displays the typical I/O set for the item. Click Find to navigate to the typical I/O set that you want to select. Apply to - Enables you to select the rule that the software implements when associating the typical I/O set. The options are: All items Applies the typical I/O set to all the selected items. Items with no typical I/O set Applies the typical I/O set only to items without an existing typical I/O set. Use this option to add a typical I/O set only to new items among the items that you selected. Items with a different typical I/O set from the selection Changes the typical I/O set of the selected items to the current typical I/O set. Use this option to add a typical I/O set to items with a modified typical I/O set definition. 98 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations Apply Profile The Apply profile maps the reference profile item properties, to the project item and creates additional items, as specified in the Profile. If we use motor item type, then for a new motor, it will create new items, and when reapplying a profile on an existing motor, the operation will result in replacing the previously applied and or associated items with the items specified in the new applied profile. The right timing on whether and when to commit this operation is an engineering decision and would be based on your project state and your workflow. Number of items to create This option is available only when you select the folder for the item you require prior to selecting Apply Options, and after you select Enable equipment profile. It allows you to specify the number of new items to create in the Electrical Index in accordance with the profile you select. Assigning a Load to a PDB/Bus/Cell/Circuit All electrical consumers and distribution equipment (PDB’s) need power source. The power source must match the requirements of the supplied equipment, in voltage levels, current consumption and by providing a suitable protection and control circuits. A load can be assigned and connected to one circuit only. SmartPlant Electrical Basic User’s Training Guide 99 Propagating Default Data and Associations A circuit may feed one or more loads or equipment. You can associate the load to a feeder from more than one environment: • From load form • Through the Batch Load Assignment • By dragging the load from the Index to the Engineer • By moving the load within the Engineer (you will learn about this later) From the load form: In case thee is not yet a circuit associated, the user is able to do the association from this form, as a one time action, after that he needs to go to other place for modifying the association. Thee are three alternatives that you can choose to assign a load: 1. You can pre-assign a load to a PDB and its bus without actually creating and connecting the load to a feeder circuit. 2. You can create a new feeder circuit on the fly by selecting the Create circuit check box. (You can also select the Create cell check box if required.) This option automatically creates a new feeder circuit under the bus, populates the circuit with the components specified in Last applied typical circuit, and connects the load to that circuit. (If a motor has an associated set of items such as 100 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations a cable, a junction box, and so forth, the uppermost associated item is connected to the circuit in the Electrical Engineer.) 3. You can associate the load with an existing spare or other feeder circuit by selecting the circuit from the appropriate list on the Properties entry form. Clicking Apply or OK commits the operation. Clicking Cancel reverts to the previous setting. Batch Load Assignment It is common practice to associate loads with a PDB not one by one, but rather using a batch operation based on some common properties. For example, all the motors of Area 1 should be fed by MCC-100, bus A. The user needs a way of assigning loads by selecting a set of loads and associating all the tags to the same PDB and bus by means of a single command. In this session you will learn how to select a PDB and a bus, select a set of loads and perform an association between them. Since this operation provides the total installed load values, it gives the user an ability to perform some iterations on the assignments without actually assigning the loads to final circuits. As with the forms, the user can perform a pre-assignment first by selecting a PDB and bus only, thereby adding the loads but not creating circuits. Alternatively, the user can SmartPlant Electrical Basic User’s Training Guide 101 Propagating Default Data and Associations create circuits on the fly automatically by selecting the Create circuits / Create cell check boxes. To select a set of loads you select a set of tags using the Tabular Editor and then click Add Selected Loads. The calculated values shown are the total calculated electrical quantities of all the assigned loads. The load balancing will be done by using the Move to cache functionality: One of the biggest challenges in electrical design is to perform load balancing. This is an operation that is done at the early stages of the project, moving loads from one bus to another, watching the total bus load, until buses are evenly loaded. SmartPlant Electrical now supports this operation in the Batch load association form. It is assumed that this operation is done in early stages of the project at which no feeder cables have been yet created between the loads and the feeder circuits and profiles have not yet been applied and populated and created massive data sets. Suppose we want to move M-1, and M2 from PDB-1, Bus-1 to PDB–2, Bus-2 In the batch load assignment, we select the loads and clicking the Move to Cache button, which will move them to the last new tab named Cached Loads: 102 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations These loads will appear in the Cached Loads tab: The next step is to select the new PDB and bus to where we want to move the loads. This will request to save the operation of the un- assign from the current bus, before he can move to other bus. SmartPlant Electrical Basic User’s Training Guide 103 Propagating Default Data and Associations Once you save this operation is committed to the data base and these loads have been dissociated from the current bus, and waiting to be assigned to other buses. Select the loads and hit the assign to bus to complete the transaction. 104 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations Note: Until all these loads have been moved and assigned, they will remain in the Cached loads Tab of each and every PDB, until assigned to a bus. Note: Variable frequency drives are used to drive motors, you can include the variable frequency drives in the grid to calculate the Electrical Index power consumption if required. Assigning Control Stations to Loads 1. Using profile. 2. Using control station assignment within the dialog box SmartPlant Electrical Basic User’s Training Guide 105 Propagating Default Data and Associations Lab 5 Apply Options 1. Verify that motors Mtr-100-1 and Mtr-100-2 set to have Rated Power of 10hp and Rated voltage of 460V. 2. Apply Sample Look Up Table to Motors Mtr-100-1 and Mtr-100-2 3. Check the result 4. Apply Profile M<10hp to motors Mtr-100-1 and Mtr-100-2 5. Check the result Assign Loads to Buses and Circuits 1. Create in the Electrical Index, new Power Distribution Board, Bus, Cell and feeder circuit: Power Distribution Board PDB-200 Buss BUSS-A Cell CELL-1 Circuit CKT-1 106 SmartPlant Electrical Basic User’s Training Guide Propagating Default Data and Associations 2. Create new motor M-6 by duplicate motor M-5.Assign motor M-6 from its form to PDB-200, BUS-A,CELL-1,CKT-1. 3. Create new motor M-7,and M-8 by duplicate motor M-5. Assign motors M-7 and M-8 using the batch load association option to PDB-200, BUS-A. SmartPlant Electrical Basic User’s Training Guide 107 Cable Sizing Cables can be sized as stand-alone cables (not associated to loads or other objects). In this case, the user needs to provide sufficient electrical characteristics in order to perform the sizing calculation. The same applies if the cable(s) are associated to loads. It is important to understand that the cable sizing procedure is iterative. Thee are several procedures involved, but not always all these procedures are executed. SmartPlant Electrical Basic User’s Training Guide 108 Cable Sizing SmartPlant Electrical Basic User’s Training Guide 109 Cable Sizing The following procedures are done for motors or loads in general. Ampacity Sizing In this procedure the software looks for a cable that satisfies the de-rated ampacity. If the software can’t find a cable that can be used, it will try to assign parallel cables 110 SmartPlant Electrical Basic User’s Training Guide Cable Sizing (starting from a minimum cable size defined in the options manager and up to a maximum number of allowable cables, also set in the option manager). Once the software finds the cable that matches the required de-rated ampacity, it will proceed to the voltage drop running validation. Voltage Drop (VD) at Running (VDN) In this validation, the software validates the cable voltage drop percentage during normal full load current running conditions satisfies the maximum allowable cable voltage drop that is set by the user. Voltage Drop at Starting Conditions (VDS) In this validation, the software validates the cable voltage drop percentage during start of the motor satisfies the maximum allowable cable starting voltage drop that is set by the user. IMPORTANT: For loads other than motor (static), only the first and second procedure is carried out. This means that the system does not require the following properties “Power factor at starting”, “Starting Current” and “Allowable Voltage Drop Percent Start”. The sizing program will recommend the required cable size according to the: Cables found in the selected cable Specification as per the project cable Same conductor Arrangement as the project cable IMPORTANT: the Reference Data Explorer catalog cables will be the source for the sizing and cable selection. It is important to make sure your cable catalog is full of all the standard cable sizes and configurations. If a specific size and arrangement is missing from the catalog, the sizing may find a different cable, which has a higher cross section (not as the one recommended by the sizing Excel program). Note: if thee isn’t any cable found with the specified construction or electrically suitable, the software needs to notify this to the user. The message should say clearly that the sizing of this cable was not successful and a proper cable was not found to satisfy the requirements. When the cable is associated to a load (the “To” side is associated with the load), the cable should inherit electrical properties from the load. The automatic data transfer is valid for loads only. For other cables association this information needs to be entered manually. SmartPlant Electrical Basic User’s Training Guide 111 Cable Sizing Ambient Temperature Correction Factor Ambient temperature affects the ampacity of the cable, meaning that in higher ambient temperatures, the cable will be able to carry less current than it is specified in its basic ampacity. The temperature effect can be the Electrical Index the calculated or taken from tables (NEC tables give these figures). The request was though not to calculate the effect, but simply enter the ambient temperature derating factor manually. Basically, the overall derating factor is calculated : Df= (Custom derating factor X Utilization factor X Ambient temperature factor) The ability of this factor to affect is set at the Options Manager, general settings: In case it is set to No, the system will set it in the formula to “1”, and this way not affecting the overall derating factor. Calculating Maximum Allowable Power Cable Length As part of the sizing procedure, the system calculates and shows the maximum permissible cable length for that particular cable type that meets the voltage drop specifications. Let us enter some sizing data and size a cable 112 SmartPlant Electrical Basic User’s Training Guide Cable Sizing This number, of the maximum cable length is calculated from the voltage drop formulae. Trying to enter a longer cable length will automatically cause the algorithm to suggest a larger cross section cable. Lets enter in the cable design length 300 meters and observe the result Select the perform sizing button again will recommend a cable of 25 mm2 SmartPlant Electrical Basic User’s Training Guide 113 Cable Sizing To accept the recommended cable select apply sizing. Viewing All Possible Combinations and Acceptable Cable Sizes in Sizing Procedure The system provides the user a window to identify all the recommended/acceptable cables that may be used for a specific data set of electrical parameters. The user will 114 SmartPlant Electrical Basic User’s Training Guide Cable Sizing be able to select any of the recommended or acceptable cable configurations of the Electrical Index the single or parallel cables. With the previous cable, let us see what possibilities the system suggests. Click the browse button adjacent the recommended/acceptable cross section gives: This gives the user the whole range of possibilities to select from, the Electrical Index the a single cable or an assembly of parallel cables of different sizes. Selecting a cable from this list will replace the current cable with the selected one. Fault Short Circuit Cable Sizing Set ‘True’ in property grid for ‘Enable Short Circuit Sizing’, will include an additional step in the sizing algorithm- to match the fault short circuit current values imposed by the network to the cable short circuit capabilities. The algorithm is based on the following formula: T +β ⎛I⎞ ⎜ ⎟ t = K × l og 10 2 T1 + β ⎝ A⎠ 2 I = Short Circuit current [Amperes]. This is the maximum permissible (allowable) short circuit current that the conductor can withstand. A = Conductor area [Circular-mils]. See appendix at the end of this document for additional information. t = Time of short-circuit [Seconds]. This value is determined by the time it take the protective devices to disconnect the power. Some standards use fractions of the frequency. Sometimes, this time is assumed to be 5 or 10 seconds. K coefficient = constant SmartPlant Electrical Basic User’s Training Guide 115 Cable Sizing Material K Copper 0.0297 Aluminum 0.0125 β coefficient = constant. Depends on the conductor material as follows: Material β Copper 234.5 Aluminum 228 T2 = Maximum allowable short-circuit temperature in Degrees Celsius. This property is the temperature at which the cable-insulation starts to damage. These temperatures have been established for various materials of insulation as follows: Material Temperature T2 [°C] PVC 150 XLPE 250 Silicon Rubber 350 T1 = Maximum operating Temperature in Degrees Celsius. Values are given below: Material Temperature T1 [°C] PVC 75 XLPE 90 Silicon Rubber 90 The above listed tables are defined at the Reference Data Explorer under the Conductor new special look-up tables. 116 SmartPlant Electrical Basic User’s Training Guide Cable Sizing In the Cable form thee is a new set of properties, related to this topic: Short circuit duration time is specified by the user (can be defined in data Dictionary). The required minimum cross section area in cmils will be calculated. The program will recommend a cable with a cmils cross section equal or larger than this minimum calculated. Project cables and the Electrical Index conductors will be automatically updated with the short circuit data of the conductors look up tables. Creating project cables, the Electrical Index the by dragging from the Reference Data Explorer or in Index or through profiles will apply automatically conductor look up table data, if exists in the project conductors and populate the above mentioned properties with look up data These properties are read/write enabled in Index, but user shall be instructed that the short circuit sizing procedure will use data from look up tables and will not look at the project conductor property value any time the system will perform the short sizing calculation, the look up table data and values will be used. Changes made in project cables conductor of the above properties data will NOT set the “sizing required flag.” In case look up data is missing the system will issue a message upon trying to perform a short circuit sizing Properties Copied from Loads The following properties that are copied from the load (static or motor) to the cable may affect the size of the cable: SmartPlant Electrical Basic User’s Training Guide 117 Cable Sizing Supply (AC/ DC) Phases Rated Voltage Power Factor at full load PF at Starting (LRC Power Factor), not valid for static loads Full Load Current Starting Current (for motors only) Conformity to Standard Auto Restart (flag) Required Data for Sizing and Selection For successful cable sizing, the following information is required: Conductor Arrangement Estimated Length and/or Design Length – the software needs at least one of them. If both are defined, the software will use the “Design Length” which is the most accurate length. Supply (AC or DC) Number of Phases (applies only if AC supply) Rated Voltage Conformity to Standard (valid for motors only) Power Factor at full load (0 < value < 1) Power Factor at Starting (0 < value < 1), (only for motors= LRC Power Factor) Routing (InAir or UnderGround) Full Load Current Starting Current (valid for motors only for voltage drop at starting validation) Auto Restart flag (currently not in use by the algorithm) Voltage drop [%] Allowable at Running 118 SmartPlant Electrical Basic User’s Training Guide Cable Sizing Voltage drop [%] Allowable at Starting (for motors only) De-Rating Factor (0< value < =1), default value set at the data dictionary, modified per each cable Utilization Factor (0< value < =1), default value = 1 If not all the information that should apply is provided, the software should notify the user to fill in the missing information. For example, “No value for Conformity to standard found.” Message is displayed when this property is missing (need to verify all required properties). Refresh Load - Changes in Electrical Data of Load If a load has an already sized cable and the load’s electrical properties are changed, the cable gets a notification that the load’s electrical properties changed. In this case, the “Refresh Data” command button of the cable should become enabled. The electrical properties that should trigger this message are those that affect the sizing of the cable and are copied from the load. Note: In this case, if the “Sizing” tab of the cable is opened, it will say that the load’s electrical properties have changed which means that the user needs to verify the sizing results. You may also perform this operation in batch, for all the power cables that the Electrical Index loads have been updated by using the following command: SmartPlant Electrical Basic User’s Training Guide 119 Cable Sizing Power Systems DC Systems SP- Electrical cable sizing support DC power systems. DC (Direct current) systems are not commonly used in power industry. These systems will be used in indoor machines usually. DC power requires special motors and usually used in machines where very high precision is required. AC Systems AC Single Phase Systems This type of cable sizing is supported by SP-Electrical. AC stands for Alternating Current. The cable sizing supports single phase and 3 phase systems. AC Two Phase Systems We will not support cable sizing of ac other than 1 or 3 phases. Whenever the user attempts to size a cable that the number of phases is other than this the system will issue a message (when trying to perform the sizing): " Number of phases must be the Electrical Index the 1 or 3, please correct " AC Three Phase Systems This type of cable sizing is supported by SP-Electrical. Three-phase systems are the most commonly used power systems in the industry. Batch Sizing of Cables In order to perform batch sizing: Select multiple cables in the Electrical Index or tabular editor (need to verify that it works from both places) -> Actions -> Cables -> Batch size cables. The dialog collects all the selected cables and performs the sizing. If everything goes OK and the sizing passes without any missing data, the recommended sizes are populated in the grid. 120 SmartPlant Electrical Basic User’s Training Guide Cable Sizing If there is missing data that prevents the system from sizing the cable(s), the “Comment” column states thee is missing data. If data is missing, all that you need to do is right-click the cable record to open the Cable Common Properties form and add the missing data. To apply sizing, check the select check box for each cable you need to perform the sizing, and hit Apply Sizing . The batch sizing process is usually necessary upon a change in cable design parameters or change in loads, where sizing of individual cables would be time consuming. Replacing Cables Replacing project cables is possible in two ways: manual replacing cable and batch replace. The rules that should apply are as follows: When a cable is replaced by another catalog cable, it should get the cable characteristics of the newer catalog cable: voltage rating, temperature ratings, ampacity, reactance and resistance, formation, sizes, materials etc. Replacing a project cable by another should retain project data of the original cable: Name and service, Design data: Procurement, from/to, associations to objects, and sizing results. SmartPlant Electrical Basic User’s Training Guide 121 Cable Sizing Any other cable property defined by the project that does not pertain to the catalog cable construction or technical specification. In case thee are Parallel cables, all these cables are replaced as per the selected cable Cable construction (number of conductors, size, formation) is adjusted according to the new selected cable. Note: After replacing the cables, you should perform a cable sizing operation. Glands Reference cable glands can be created in the Reference Data Explorer: With the use of the following UI specify the major gland data: 122 SmartPlant Electrical Basic User’s Training Guide Cable Sizing While the General tab defines its certification and type basic properties, the Details Tab specifies the more detailed dimensions. While the inner and outer dimensions provide information on the size of cables that it can accommodate, the Armor clamp flag, when checked means that this gland is suitable for armored cable (has metal armor) You may associate reference glands to reference cables in the Reference Data Explorer from the new Connections tab: SmartPlant Electrical Basic User’s Training Guide 123 Cable Sizing This will allow creating the project cables already fit with some default glands. So, dragging a ref cable or performing some apply option that involves cables will create project glands. Project Cables can be associated with reference glands on a one to one basis and in batch. Lab 6 Cable sizing Size cable C-PWR-P-1 Enter the following data: General Tab 124 SmartPlant Electrical Basic User’s Training Guide Cable Sizing Design Data Tab Connections Tab SmartPlant Electrical Basic User’s Training Guide 125 Cable Sizing Sizing Data Tab Perform sizing, and apply sizing if required. 126 SmartPlant Electrical Basic User’s Training Guide Reports Reporting is the process of retrieving information from the database and displaying the information as formatted output. At any time during the design creation process, you can create a report. Each report consists of a Microsoft Excel workbook and a report definition, which describes the data to collect and how to organize the data in the workbook. Each report you create is based on an item type. This item type serves as the starting point for collecting data for your report. Examples of item types include motors, cables, control stations, and buses. Several default report templates already exist; however, reports are fully customizable. You can create your own reports that contain the information you want to see in a format you choose. Report Writer The SmartPlant Electrical report writer lets you quickly and easily create and modify reports. The report writer runs with Microsoft Excel and therefore allows all formatting to be done with Excel formatting commands: for example, drawing lines, sorting column data, and inserting objects. When you edit the SmartPlant Electrical report, you use an add-on toolbar to define and map properties in the database to a specific column in the Excel file. This toolbar also lets you filter the database information, sort the information, and format the column header information. You open the report writer from the SmartPlant Electrical environment. Click the Reports menu for the various options. These options let you create new reports, modify existing reports, delete reports, and run the Electrical Index the project reports (plant report) or user-level reports (my report). Project reports are stored in the server directory (Option Manager specifies this default directory) My reports are stored locally on your machine (under \Profiles\<username>\My Reports\Output). Creating New Report Templates To create a new report template, click Reports > New. The Report dialog box lets you create a new report from by selecting the Blank value for the Source template. You can also select any existing report to use as a template SmartPlant Electrical Basic User’s Training Guide 127 Reports or starting point for a new report of that item type. All reports stored for the project and the reports stored for the current user are displayed in this list. You can define three report types for a new report: Fixed format, Tabular format, and Composite format. • Fixed format. For a report that is defined as fixed format, each item that you select for the report is printed on a separate sheet with no repetition of data. The fixed format type is similar to the instrumentation spec. sheet reports. • Tabular format. A tabular report prints all of the items selected on a single sheet. Most of the SmartPlant Electrical delivered reports are defined as tabular format. • Composite format. A composite report is a combination of fixed format and tabular format. The first sheet is fixed format and contains the data common to the items on the subsequent sheets. The subsequent sheets have the specific item data. For example, a pump vendor report would have the vendor’s name and information on the first sheet, and the listing of the pumps from that vendor on the second sheet. If you click Add to project reports, the report is stored in the project reports location defined in Options Manager. If you do not click this checkbox, the report is stored in the user report directory. By default, the user report directory is located in your user name profile directory. SmartPlant Reports Toolbar After you create or modify the report, Microsoft Excel is opened, and the SmartPlant Reports toolbar is displayed in the worksheet. This toolbar lets you define attributes that are available to the report and define the sorting criteria for this data. The toolbar also lets you filter the data for a specific value or range of values. You define the report header information here as well as map the defined attributes to specific cells. When you click Define on the SmartPlant Reports toolbar, a dialog box is displayed, allowing you to create, edit, and remove items in the report tree view. When you click Define on the Define Report Contents dialog box, a list of attributes is displayed for that report item. From this dialog box, click Sort to sort by one or by multiple attributes in ascending or descending order. The Filter tab allows discrimination on a certain value or values for the property. 128 SmartPlant Electrical Basic User’s Training Guide Reports Items and Properties that can be used in the Reports Defining items and the properties that you wish to see in your report is procedure that requires a knowledge in the data model of Smart Plant Electrical. Thee can be reports that are very easy to retrieve the required data and thee are such that are more complex. The available list of items and related properties available is based on the data model associations, and you may need to select the Electrical Index the a single item type or use a chain of item types- all depending on your needs. Thee is more than one way of accessing items and data, and it depends from which item type. A simple report that would retrieve the direct properties of a appear as follows: SmartPlant Electrical Basic User’s Training Guide 129 Reports 130 SmartPlant Electrical Basic User’s Training Guide Reports To run the report: SmartPlant Electrical Basic User’s Training Guide 131 Reports Report Options Options on the SmartPlant Reports toolbar define the report header and basic information in the body of the report. The Report Options dialog box applies only to tabular and composite reports because the fixed report prints each set of data on a different sheet. 132 SmartPlant Electrical Basic User’s Training Guide Reports Skip lines between rows defines the number of lines between each printed row of data. Rows in report header defines the basic report information. Project name, unit name, date, report title, and company logos are examples of information that goes in a report header. This information is printed on each page of the report. Also, if any of the information mapped in the header changes, the software prints a new page with the header information. Because a page break occurs if the value for an attribute changes in the report header, the basic report information (attributes) should not be mapped in any rows in the report header. Otherwise, every time a value changes in the header, the information prints on a new page. In the example above, the mapping of attributes would begin in row 6 or after. You may cause the header to be displayed on each page by File-ÆPage setup and selected the Sheet tab to “row to repeat at top” Map Attributes After you define attributes, they are available to be mapped to specific columns and rows in the spreadsheet. Use Map Attributes on the SmartPlant Reports toolbar to place attributes. Point to the cell to insert the data, and select the item from the Map Attributes list. Editing Report Templates To edit an existing report, click Reports > Edit. In the Edit Report Template dialog box, you can change the title and open the template in Excel for editing. Deleting Reports To delete existing reports, click Reports > Delete. Depending on how project permissions are set, you can delete a single report or multiple reports. Running Reports Reports >Plant report or My Report, and select the report you want to run. SmartPlant Electrical Basic User’s Training Guide 133 Reports Run Reports and Specify Items Through Tabular Editor Allows you to choose a report and specify what items to report on. For this you need to open tabular editor first. Current selection - Produces a report containing the items currently selected in your current table. This option is not available if no table items are selected. Entire table - Produces a report containing the contents of the Tabular Editor. Thee is no need that the opened table will have properties matching the properties of the report. One property is enough. Shipped Reports SmartPlant Electrical provides sample special reports (more complex reports that use embedded VB code to fetch and organize data) that user can customize or use as 134 SmartPlant Electrical Basic User’s Training Guide Reports reference to create his own standard. The following list is a partial list out of the ones actually shipped • All Feeder Load Summary Report (rated and consumed values) • Cable Schedule • Cable Sizing Summary • Cable Take-off • Electric Load List • Instrument and Cabinets • IO Signal List • PDB Load Summary • PDB Load Summary by Operating Mode • PDB Schedule • Power Distribution Panel Schedule All Feeder Load Summary Report (Rated and Consumed Values) This report is a bus load summary report that includes “roll up” of downstream loads. The report collects all the loads that are connected to the circuits that are tied to the specific bus, including circuits that feed other buses, looks for the Electrical Index connected loads, performs a roll up (brings the total downstream loads up to the selected bus) and calculate the total load, based on some Options Manager or preferences settings, definitions and factors, as follows: -In the Option Manager or preferences, the user will define: Whether to calculate the total load based on individual coincidence load factor or use the bus averaging coincidence factors Whether to include coupled and tied buses -For each bus, the user will be able to define if the system should calculate the connected loads, or to use the Bus rated values Cable Schedule Cable schedule provides a detailed list of all the project cables. Besides the cable tags names and the Electrical Index type, stores part numbers the report provides the origin and destination of the cable side 1 (“to” side) and side 2 (“from” side). These “to” and “from” information will include the tag of the item this side is assigned to- in case the to/from is a PDB, PDB/Bus/Cell/Circuit Tags will be provided. SmartPlant Electrical Basic User’s Training Guide 135 Reports In case the to/from is a panel with internal circuits, these tags will be provided. Cable Sizing Summary Cable Sizing Summary is a report that lists all the cable sizing input and output data for a specified power cable. This report is useful as a quick reference for your sizing considerations and criteria at any time during the life cycle of your project. This report provides the following information: Cable tag name. Cable origin and destination sides (the To and From cable sides). The To and From information includes the tag of the electrical item that the cable is assigned to. Input values such as load voltage, full load current, number of phases, and so forth. Sizing results such as reference cable, conductor size, calculated voltage drop, and so forth. Cable Take-off This report provides a summary of all the different cable types of all categories, including any none sized cables, that the user has created in the project. This report will provide technical details about the type of cable and calculates the totals estimated and design lengths of each type. The total required length for Single core conductor configuration cables lengths will be calculated taking into consideration the number of conductors of each of the cables. ( the system multiplies the number of conductors per phase by the cable length) Electric Load List Electrical Load List is a report that you generate based on the load item type. The software retrieves the load tags with the relevant load tag data, such a rated power, brake power for motors, as well as values for efficiency, power factor, full load current, and so forth. 136 SmartPlant Electrical Basic User’s Training Guide Reports Instruments and Cabinets This report is actually a report based on Equipment table, and its main use is to be a template so user can create a registered report that can be used to publish to INtools, instruments and cabinets that were retrieved from INtools loads Signal List The report is used as a template for creating registered reports that can be used as published document to send IO signals to INtools. PDB Load Summary This report provides a load summary for Power Distribution Boards. The main difference of this report from the All feeder load summary is that thee is no roll up in this report and the load summary includes directly connected loads only. Its intention is to provide a list of the associated loads connected/associated with a PDB, sum the Electrical Index electrical kW, kVAR and kVA and enable the user to evaluate what should be the required capacities that this PDB will need to deliver. The report calculates 2 summaries. One, that includes only the continuous and intermittent loads and second, all the connected loads, including any spares and standby loads. The system uses the individual coincidence factors of the loads. The Loads For each associated load, the report will list the load rated power, its demand factor, operating mode, operating factor and its electrical consumed and rated values. The report does not consider downstream or tied or coupled PDB’s or other equipment that may have been connected and fed from the selected PDBs. Calculated Results The report will group the loads per PDB (sort them) and sum the electrical quantities to provide the total running (consumed) load and the total peak load based on the coincidence factors that has been defined for each and every load. Within the PDB, the loads are sorted per the Electrical Index bus association and then alphanumerical within the bus. The report multiplies each electrical load by its coincidence factor (x, y, z or zz). Based on the total kW and KVA’s, the report will calculate the required power factor. Calculated values and Results are not stored in the data base and they are recalculated each time the report is generated. The PDBs The report doesn’t filter out any specific PDB and if not filtered, it will list all the PDB’s. In case you want a specific PDB, you should use the filter to filter the specific PDB SmartPlant Electrical Basic User’s Training Guide 137 Reports Each PDB will be displayed on a separate page, with the first page allocated to non those loads that are not related and associated to any PDB. PDB Load Summary by Operating Mode The "PDB Load Summary By Operating Mode" report is intended to be a complementary to the new "All Feeders Load Summary" report, which calculates the Running and Peak loads according to each load coincidence factor or to each load feeding bus coincidence factor. As it is sometimes required (especially for off shore platforms) to execute the load summary calculation per special operating modes like emergency or life support systems, the software was enhanced to provide definition of up to 10 operating modes factors (Duty & Load factors) to each load or bus, and the new "PDB Load Summary By Operating Mode" is calculating the total power per each one of the 10 op. modes. The "PDB Load Summary By Operating Mode" is subjected to same preferences like the "All Feeders Load Summary" report (meaning: coupling method and usage of Load or Bus factors) The formula used to calculate the total power for each op mode is not the same as used in the "All Feeders Load Summary" report. PDB Schedule This report is a deliverable that one may generate to list all the contents of a certain selected PDB. It will list, per selected PDB, all the circuits, the loads, the internal components and the Electrical Index technical details of each circuit, its associated schematics drawing, rated powers Power Distribution Panel Schedule PDB Schedule is a report that is intended for single phase loads connected to distribution panels. The report specifics are as follows: The report lists, per selected PDB, all the circuits, each with its protection device type and current rating (the software supports a single protection device per circuit) and the loads associated with each circuit. 138 SmartPlant Electrical Basic User’s Training Guide Reports The report sorts the circuits by phase and then by circuit (all the circuits for phase 1, then phase 2, and then phase 3). The report calculates the following: Full load current for each phase, Total load current of the bus, Total kW per phase, Total kW per bus. Lab 7 Create custom report Source Template: Blank Report Name: Power Cable List Item type: Cable Report type: Tabular format. Attributes: Item Tag, Cable formation, Cable Specification, Ref Equipment.Item Tag Filter: Add filter to retrieve power cables. SmartPlant Electrical Basic User’s Training Guide 139 Electrical Engineer The Electrical Engineer, combined with the Electrical Index as a source, provides for: • Navigation through your electrical network • Connection between your power distribution equipment of the network infrastructure • Modification of relations between the power equipment (electrical flow of energy). The above procedures are performed by dragging items. The Electrical Engineer shows any electrical entity that has at least one electrical relation. In the root of the tree view, the Electrical Engineer shows entities which have electrical children but not parents. Notes: Some standalone electrical equipment will be shown as well - generators, transformers, buses and the Electrical Index circuits. You can open more than one instance of the Electrical Engineer. In addition to the above, the Electrical Engineer provides the following functionality from the right-click menu: • New SLD • Open SLD • Rename • Find in Electrical Index • Find other Parent items • Dissociate • Expand all sub-items • Show Only • Show in New Window • Find in SLD • Common property • Add cable • Common Properties • Select Alternative Power Source SmartPlant Electrical Basic User’s Training Guide 140 Electrical Engineer Lab 8 8.1. Observe that the following items that you have created in previous labs have been automatically made visible in EE • Generator G-001 • Transformer T-001 8.2 1. In EI find the power distribution board, PDB-200 and add to it new bus, Bus-B 2. 2. In EI create new Motor, M-9. 3. Assign M-9 to Bus-B by drag the M-9 from EI to Bus-B in EE. 4. Assigning the motor to the bus create new cell, and new circuit. Name the cell, CELL-1, and the circuit, CKT-1. *8.3 1. Associate the loads M-100, M-101, M-102, M-103, H-102 to the appropriate circuits, by drag and drop the loads from EI to the circuits in EE. 2. Connect the riser circuit, MCC-201 Bus A/B Bus Riser, to the coupler circuit, of MCC-201 Bus A/B Coupler, to create a bus tie. 3. Connect the riser circuit, MCC-202 Bus A/B Bus Riser, to the coupler circuit, of MCC-202 Bus A/B Coupler, to create a bus tie. 4. Connect the cable, C-Main Utility Supply to the generator G-001. 5. Connect the incomer circuit, SW-300 Incomer, to the cable, C-Main Utility Supply. 6. Connect the cable, C-T-001/P to the circuit, MCC-201/2 Feeder. 7. Connect the transformer T-001 (Primary) to the cable, C-T-001/P. 8. Connect the cable, C-T-001/X, to the T-001, X (Secondary). 9. Connect the cable, C-T-001/Y, to the T-001, Y (Secondary). 10.Connect the MCC-201 Bus A Incomer to the cable C-T-001/X. 10. Connect the MCC-202 Bus A Incomer to the cable C-T-001/Y. SmartPlant Electrical Basic User’s Training Guide 141 Single Line Diagrams Smart Plant Electrical enables you to generate two types of single line diagrams: 1.Power Distribution Board-based single line diagram. 2.Electrical Engineer-based single line diagram. Power Distribution Board-based single line diagram - is a project document provided for the vendors so they can construct the PDB. It includes a power distribution board general arrangement drawing and a power distribution board (PDB) schedule. The software generates a single line diagram for a selected power distribution board that contains all the PDB buses, circuits, circuit components, and their inter-connections (bus couplings). Electrical Engineer-based single line diagram – is a main or key single line diagram of the electrical network for a selected set of items created according to the generation options that you predefine. SmartPlant Electrical Basic User’s Training Guide 142 Single Line Diagrams Generate a power distribution board-based SLD 1. Select a PDB in the Electrical Index. 2. Right Click -> Generate SLD, or from Main Menu select Action -> Generate SLD for PDB. 3. Define the generation settings. 4. Generate the SLD. 5. Add annotations (if required). 6. Add/modify revisions by clicking Edit > Document Properties, then Add/Remove Revisions/Description, and so forth. 7. Save the document by clicking File ->Save. Generate an Electrical Engineer-based SLD 1. Select one or more electrical objects in the Engineer. 2. Click File > New > SLD or right-click, and on the shortcut menu, click New SLD. 3. Define the drawing options. 4. Generate the SLD. 5. Add annotations (if required). 6. Add/modify revisions by clicking Edit > Document Properties, then Add/Remove Revisions/Description, and so forth. SmartPlant Electrical Basic User’s Training Guide 143 Single Line Diagrams 7. Save the document by clicking File ->Save. Open and Modify an Existing a power distribution board-based SLD 1. Select a PDB in the Index 2. Right-click -> Generate SLD, or from Main Menu select Action -> Generate SLD for PDB. Open and Modify an Existing Electrical Engineer-based SLD 1. Select one or more electrical objects in the Engineer. 2. Click File > Open > SLD ,or right-click, and on the shortcut menu, click Open SLD. Single Line Diagram Drawing Options Power distribution board-based SLD 144 SmartPlant Electrical Basic User’s Training Guide Single Line Diagrams Electrical Engineer-based single line diagram. SmartPlant Electrical Basic User’s Training Guide 145 Single Line Diagrams Managing the SLD The software allows you perform various actions with an open single line diagram. Apart from regular actions in a drawing such as zooming, selecting, saving, and so forth. Moving items You can select an item and drag it to another place in the drawing. Entering and modifying item properties You can select an electrical item and then enter or modify its properties in the Properties window. Changing the line type, line color and line width of a selected bus You can change the line type, line color and line width of a bus. 146 SmartPlant Electrical Basic User’s Training Guide Single Line Diagrams Note that the software retains new line display settings only if you save the SLD as an external document. Otherwise, after reopening the SLD, the software displays the original bus symbol. You can use Options Manager to change the symbol that the software uses to represent buses. To create a new symbol for buses, use Catalog Manager. Annotations and Redlining • You can mark up single line diagram using text or symbols as annotations. The software saves annotations in the same layer as the graphical elements of the drawing • Redlining appears in a separate drawing layer and you can hide and display redlining as you require. When opening single line diagram that contains redlining items, the software automatically displays the drawing in redlining mode. You can switch back to regular mode and modify the drawing as needed. The software saves the existing redlining items regardless of whether you open the drawing in redlining mode or not. You can add text, symbols, lines, circles, rectangles, and watermarks as redlining. Saving an SLD as an External File You can save the SLD from the file menu as external file. Printing an SLD While the SLD document is open, you can print the document from the file menu. Lab 9 • Generate SLD for SW-300 from the Electrical Index and from Electrical Engineer • Generate SLD for G-001. SmartPlant Electrical Basic User’s Training Guide 147 Schematics Schematics A schematic is a graphical representation of wiring and motor control systems. You create a schematic by assembling it from typical blocks. A block is a graphical representation of an electrical item. Blocks are parts of a complete drawing. To create a block, start by creating an entire drawing in Catalog Manager or any CAD application such as SmartSketch, AutoCAD, or MicroStation. Once the complete drawing is ready, you select a part of the drawing and turn it into a block. You can generate schematics for the following item types: • • • • • • • All loads All converting equipment All disconnect equipment Circuits Buses Generators Battery banks The software can generate a schematic by retrieving data for power related items from one block or several blocks. If your generated schematic drawings contain the same information (that is, the information repeats itself in identical sections of different schematic drawings), you should consider creating a schematic block for the repeated parts so that this single block can be used by several other schematic drawings. Note that you can create schematic drawings that include several sheets. Multi-sheet schematics are mostly used when you need to display complex electrical equipment for which a single sheet is not enough to show all the relevant wiring details of the equipment. After creating a block, you define the macros for that block. A macro is the smart text that you attach to the block graphic. The software retrieves this smart text from the database and attaches it to the block, thus making it part of the block file. You can create your macros in Catalog Manager, SmartSketch, AutoCAD, or MicroStation. Also, you must attach your blocks to templates. A template contains the definition for the desired title block, border, and page size. You attach your blocks to templates in Catalog Manager, SmartSketch, or any other CAD application. Before generating a schematic drawing, you create a typical block and a typical schematic that you will attach to a load for which you want to generate a schematic drawing. Typical blocks Typical block associated with drawing file (block or symbol) and it’s the basic element for Typical schematic. There are several ways to create a block/symbol. Lets look at the following drawing. 148 SmartPlant Electrical Basic User’s Training Guide Schematics You will notice that there are 2 groups of symbols called Block 1 and Block 2. The border makes Block 3. Assume, for the sake of this discussion, that this was a representation of how you wanted your schematics to appear, except with a variation on block 1, which we will call Block 1A. The easiest way to create your symbols would be to make 4 copies of this drawing (one for each block that you want to make a symbol from – Blocks 1, 1A, 2, 3). Delete everything else from the particular drawings except the graphics that you want to see on that symbol. So Symbol #1 (a drawing of just the graphics needed for Typical Block #1) may look like this: Symbol 1A may be some variation on this set of graphics. Symbol 2 may look like this SmartPlant Electrical Basic User’s Training Guide 149 Schematics Of course, you will make a template out of the Block #3, which may look like this: Notice the relationship between the placement of these Blocks and the ‘Point of Origin’. This is how the software places the symbols or blocks in the correct physical relationship to each other and to the sheet. Once the symbol files are prepared, you can save them in whatever format you are working. Then all that is left is to add your macros and create a Typical Block from that Symbol File. The above is true for all types of drafting packages. Create a Typical Block 1.From RDE select Typical Block folder > right click -> New Typical Block 2.Give it a Name 3.Open Common Properties of the new block. 4.Select a block type. 5.Browse to the drawing file and select the symbol/block you need. 6.Select Apply or OK. 150 SmartPlant Electrical Basic User’s Training Guide Schematics You can view the block at any time by clicking the View button. If you want to create another block while you are in this window, just select add and create another one. Create a Typical Schematic 1.In the Reference Data Explorer, right-click the Typical Schematics folder, and then click New. 2.Type a name of up to 80 characters for the typical schematic. 3.Right-click the schematic and click Common Properties to open the Typical Schematic dialog box. 4.Select template. 5.Select Add to add a typical block (you can 1 or more blocks). 6.To finish select Apply or OK. You can view the typical schematics at any time by clicking the View button. SmartPlant Electrical Basic User’s Training Guide 151 Schematics When this typical schematic is used to create a schematic of a particular motor, the macros will be replaced with specific data from that particular motor. Create a Schematic Drawing in SmartPlant Electrical Creation of a drawing block file (sym, dwg or dgn), using the Electrical Index the integrated SmartPlant Electrical Catalog Manager or by using any of the following independent software: SmartSketch, Autocad or MicroStation. In the block file, the user will draw its graphics (as expected to appear with the Electrical Index correct displacement from page origin) and in addition set of required Smart Text labels or “macros”, later on, to be replaced by SmartPlant Electrical system with relevant data from the SmartPlant Electrical database, according to the attached object. Create a new typical block item in the Reference Data Explorer . Edit the new typical block item properties, to attach it with a relevant drawing block file (one or more). Create a new typical schematics item in the Reference Data Explorer. Edit the new typical schematics properties to attach it with a relevant the Reference Data Explorer typical block item (one or more). Set each typical block sequence (in case two or more blocks of same item type are used that typical schematic e.g. two Control Station blocks etc). Assign a typical schematics to a load the Electrical Index the through the profile or through the pop up menu: 152 SmartPlant Electrical Basic User’s Training Guide Schematics The associated schematic dialog follows: SmartPlant Electrical Basic User’s Training Guide 153 Schematics In case macros have not been resolved, you may want to investigate more indepth: In case there is equipment related to the load and do not have macros on the typical schematic used, you can find it in the Unresolved Items list: The following schematics and the Electrical Index relevant graphical blocks can be exercised: Schematics of Motor Type A, a standard motor with a control station, circuit. 154 SmartPlant Electrical Basic User’s Training Guide Schematics Generating Schematics in Batch Mode You can generate your schematics in batch by simply selecting a number of motors the Electrical Index the in the tabular editor or in the lower pane of the Electrical Index: The following dialog box appears: You can save the generated schematics as external CAD files in any commercially available CAD format and have them printed on the fly. Macros You place macros on each block (or symbol) to retrieve relevant information from the database. The macro name describes where (what table/attribute) it will find the information.If you place a Macro called ‘Motor.ItemTag’ in a symbol or block, then create a Schematic (or SLD that uses that symbol), the program will replace the macro SmartPlant Electrical Basic User’s Training Guide 155 Schematics with the ‘Data’ in the database from the table ‘Motor’, attribute ‘ItemTag’. This particular Macro happens to be the attribute that contains the name of the motor. So, when this Macro is placed in block (or symbol), and a Schematic (or SLD) is created for a particular motor, the program gets the name of the motor and places it in the drawing. The formatting of the text put in the drawing is the same as the formatting of the Macro. Macro Syntax The macro text has to contain the SmartPlant Electrical item name, its required property name, and a sequence number, according to the following syntax: &[ItemTypeName].[Property].[Sequence] For example, to specify a name (item tag) of a motor, the text label has to be: &Motor.ItemTag.1 If a particular block contains several items of the same item type (that is, several cables, control stations, and so on), you have to use the sequence number to ensure item uniqueness. Annotations and Redlining • You can mark up schematic drawings using text or symbols as annotations. The software saves annotations in the same layer as the graphical elements of the drawing • Redlining appears in a separate drawing layer and you can hide and display redlining as you require. If a drawing has more than one sheet, you can create redlining and hide or display it independently for each sheet. Therefore, while working in redlining mode, you cannot access any items in the main drawing layer. The software saves the drawing with the redlining items. When opening schematic that contains redlining items, the software automatically displays the drawing in redlining mode. You can switch back to regular mode and modify the drawing as needed. The software saves the existing redlining items regardless of whether you open the drawing in redlining mode or not. You can add text, symbols, lines, circles, rectangles, and watermarks as redlining. Create Templates (template for Schematic and SLD) 1. From File menu select New -> Template. 156 SmartPlant Electrical Basic User’s Training Guide Schematics 2. From File menu select Sheet Setup and select the required page size. 3.From Edit menu select Insert Symbol, and browse to your template folder to select a symbol template. SmartPlant Electrical Basic User’s Training Guide 157 Schematics 4. From File menu save the new Smart Plant Electrical Template as Smart Plant Electrical file type ([Name].SPE). Lab 10 Create new typical schematic and generate motor schematic 1. Create 3 typical blocks: Block 1 Typical block name: MTR_A Blcok Type:Motor File name: MotorTypeA.sym Block 2 Typical block name: FDR_A Blcok Type:Circuit 158 SmartPlant Electrical Basic User’s Training Guide Schematics File name: FeederCircuitA.sym Block 3 Typical block name: CS_A Blcok Type: Control Station File name: ControlStationA.sym 2. Create a Typical Schematic NAME: MTR_SCM_A Template: AWide.spe Blocks: MTR_A,FDR_A,CS_A 3. Generate schematic Generate schematic for motor M-1 using typical schematic MTR_SCM_A and save the document. Note: 1. Apply the typical schematic first. 2. Save the document also as external file ([Name].SPE file format). SmartPlant Electrical Basic User’s Training Guide 159 Associating Documents You define a document reference by adding a reference to the list of document references. You can then associate this reference with an external file. The software adds this association by storing the file path in the database. After you define external document references, you select one or more electrical items and associate them with external documents. You can associate an electrical item with a document reference or with an external file that is linked to the document reference. The software allows you to associate single or multiple electrical items with the same external document. Also, you can associate the same external file with multiple items in the software. Define a Document Reference => => => SmartPlant Electrical Basic User’s Training Guide 160 Schematics Associate a Document => => SmartPlant Electrical Basic User’s Training Guide 161 Schematics Lab 11 Define and associate Document 1.Generate schematic for motor M-100 (using typical schematic MTR_SCM_A). Save the generated M-100 schematic as external smart plant electrical file format (M-100.SPE). 2.Add new reference document using the external file M-100.SPE and name the document M-100 External 3. Associate the reference document M-100 External to motor M-100. 162 SmartPlant Electrical Basic User’s Training Guide Archiving Documents Smart Plant Electrical let you revise, archive and compare document. 1. From option manager verify the archive documents is enabled. 2. Save the change, and reopen Smart Plant Electrical. 3. Generate a new SLD from EE. Select the feeder circuit M-100 Feeder as starting point for the new SLD. SmartPlant Electrical Basic User’s Training Guide 163 Archiving Documents 4. Close the generated document M-100 Feeder. => => 5.Revise the document M-100 Feeder by open the document (select the document from the document folder -> Right-Click and select open). 164 SmartPlant Electrical Basic User’s Training Guide Archiving Documents 6.While the document open select the document from the document folder, right-click and select Document Properties. 7. In the Document Properties windows select P0, P1, P2… for revision method, and select New to add revision P0. Close the document. 8. To verify the new revision has been archived, reopen the document properties. SmartPlant Electrical Basic User’s Training Guide 165 Archiving Documents 9. Change motor rated power of M-100 from 1 hp to 1.5 hp 10. Select the document M-100 Feeder , right-click compare document 11. Select the Compare button, compare the current state of the document data with the data in the document of its last saved revision and creates • A tabular report that includes a log of all the changes, with a reference to the Index numbers as they appear in the drawing itself. • Document that shows clouds around items that has been changed since last saved issue. Index numbers are used to identify the changes 166 SmartPlant Electrical Basic User’s Training Guide Archiving Documents DS-10 120 A M M-100 1.5 hp P0 Note: Same workflow of revise, archive and compare works for schematics document. Global revisions The ability to assign a specified Global revision to a set of documents is a powerful and important feature often requested by those who need to issue deliverables packages all at once, all in same or in a specified revision number. Thee are several options that can be used in conjunction with this feature, and these can be seen in the Global Revision Dialog. To open the global revisions dialog select Global Revision from action menu. SmartPlant Electrical Basic User’s Training Guide 167 Archiving Documents • Add Revision add new revision to all selected documents. The system will add a new revision (P0, P1 type; A, B, C type; 1, 2, 3 type, or any “other” type). The system will identify the requested method and if needed will modify the method window accordingly. • Upgrade revision upgrade the selected set of documents to next higher revision level to each document. This opens a selection window from which user select the method of revisions for documents that have no revision method yet defined or the revision method is “other” • Delete last revision delete only the last revision of the selected set of documents. • Delete All revisions delete all document revisions. Deliverable Project Reports (register report) Project reports (plant reports), that were created as templates can be saved as project deliverables, that have revision level, and can be archived for future viewing and compare. The idea is to take the Excel templates, that were created in the classic report engine as plant report and use them as the source for generating or declaring project reports. The procedure involves what is called Report Registration- meaning, to take an existing Excel template report and to transform it into a Project Document. Exercise Lets see how we can create a project document called “Motor List.” 1.Select Register Report from the Actions menu. 168 SmartPlant Electrical Basic User’s Training Guide Archiving Documents 2.This invokes the Register Report Common Properties dialog box, which enables you to define the project document: 3.Select a report template that will be used as the basic report, click the ellipse button to open select report dialog box, and select the ElectricalLoadList.xls. SmartPlant Electrical Basic User’s Training Guide 169 Archiving Documents 4.Name the document, select Load for Report item type. 5.Click OK to create a new document under Registered Reports 6. Revise, archive and compare the register report works the same as compare the others document type (SLD or schematic). Select the register report Motor List, right click and open the document. 170 SmartPlant Electrical Basic User’s Training Guide Archiving Documents 7.While the document is open, select the Motor List document from the registered Reports folder, right click and select Document Properties. 8.In the Document Properties windows select P0, P1, P2… for revision method, and select New to add revision P0. Close the report. SmartPlant Electrical Basic User’s Training Guide 171 Archiving Documents 9. To verify the new revision has been archived, select the document, right click and select document properties. 10. Change motor rated power of M-100 from 1.5 hp to 2 hp 11. Select the Motor List document, right-click and select compare document to open the Compare Document dialog box. Select the Compare button, to compare the current state of the document data with the data in the document of its last saved revision. 172 SmartPlant Electrical Basic User’s Training Guide Archiving Documents The comparison results are shown in two reports: • The Load List itself, with marked changes of properties, calculated values that result from changes in properties, attributions (motors moved from one PDB to another.) and new tags inserted. Renamed will be considered as deleted and newly created. SmartPlant Electrical Basic User’s Training Guide 173 Archiving Documents The modified properties will be colored in blue and the new records will be marked in bold. • The second report is a summary of all changes, named “Registered comparison report” The report divides each tag by a bold line, the first record being the previous value, followed by the current value. Lab 12 Compare register report 1.Change motor rated power of M-100 to 3 hp. 2.Duplicate M-100 and name the new motor M-579. 3.Run compare report for the register report Motor List and compare its current data with the last archived revision (P0). 174 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Batch Assignment of Control Station Cables When we apply profiles to a set of motors which are connected to feeders, this operation results in creation of a set of control stations with the Electrical Index related control and instrumentation cables. The “from” side of these cables remains unassociated and you have to connect them manually. Assigning each one to the same feeder circuit which feeds the motor can become a very time consuming process. We have ability to automate this procedure as follows: 1.Close Smart Plant Electrical. Open Options Manager, under General Settings, set the Connect Cables of Control or Instrumentation to Equipment Circuit to Yes. Save the change in the option manager, and reopen Smart Plant Electrical. 2.Consequently, applying a profile or control station options to a motor that is connected to a feeder automatically associates the control station cables with the motor feeder, as shown below: 2.1. Select motor M-100 SmartPlant Electrical Basic User’s Training Guide 175 Miscellaneous Features 2.2.Apply the typical control station, ‘Start-Stop Station type A’ 2.3.After applying the typical control station to the motor, the software create new control station and 2 cables (control and grounding). The ‘From’ side of the control cable is connected to the motor feeder circuit. 176 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features However, this feature doesn’t include grounding cables. This category will not be routed to the circuits. The other variations of this feature is described in the following paragraph: If the motor has control stations and then after that is connected to a feeder, once the motor is connected to the feeder all the related cables of the control stations will be automatically associated with that feeder circuit (except for the grounding). Create a motor with a control station and cables. After creating them, have the motor dragged to a feeder circuit Observe that the control and instrumentation cables of the control station have the “from” side connected to the circuit. In batch, selecting a set of control stations, using a Batch command, “Associate cables with Main equipment feeder circuit” will result in having all the cables connected to the feeder circuit of the Electrical Index related main items. SmartPlant Electrical Basic User’s Training Guide 177 Miscellaneous Features External Drawings Allow you to create none typical drawings using CAD and save them as SPEL documents, uses the SPEL revision management. The miscellaneous drawing path defined in the option manager To create new miscellaneous drawings do the following steps: 1.Select the Miscellaneous Drawings folder, right click, and select New Miscellaneous Drawings. 2.Select template and enter document number and select OK. 3.Close and save the new document. 4.Select the new document from Miscellaneous Drawings folder, right click and select open. 5.From Edit menu select insert, symbol and browse to you Miscellaneous Drawings folder to select symbol for you drawing. 178 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features 6.To insert and locate the symbol, select the symbol from the Select symbol file dialog box, select the open button, left click and insert the symbol. Then to adjust the symbol, select it with left click and rearrange. 7.Close and save the document. The document properties dialog box that available for SLD,Schematics and Register report documents available also to the Miscellaneous Drawings, and you can revise the document. SmartPlant Electrical Basic User’s Training Guide 179 Miscellaneous Features These miscellaneous drawings may be found as shown in the following screen: and can be associated to any item: Transfer Switches Transfer switches are 2 way manual, non-automatics or automatic switches, that are used to switch or transfer an essential load from a power source to another, backup power source. Automatic Transfer Switches are an integral part of the power generation process, allowing smooth and immediate transfer of electrical current between multiple sources and the load. When the generator is operating, the transfer switch prevents dangerous feedback of current to the utility’s system. It also ensures that different 180 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features power sources are fully synchronized before the Electrical Index power is combined or loads are transferred, which is imperative for safe operation. The transfer switch senses when utility power is interrupted, and starts up the generator if the utility power remains absent. In about five to ten seconds, when the generator is producing full power, the transfer switch disconnects the load from the utility and connects it to the generator, restoring electricity to the load. The transfer switch continues to monitor utility power, and when it is restored, switches the load from the generator back to the utility. Once the generator is disconnected, it goes through a cool-down routine and is automatically shut down. These devices are standalone, usually housed in cabinets or mounted on wall, have 2 inputs to accept the mains and backup power source and one output, which connects to one of the switch inputs. The transfer of the power from input 1 to input 2 can be done the Electrical Index the manually, switching the load from one to a second power source, or automatically, via a monitoring and protection circuitry that senses a loss in power in one of the sources and then switches to the alternate power source. A new subfolder exists now under Power Distribution Boards: The equipment type for this item will be set to Transfer switch: The operation in the Electrical Engineer is as regular bus with 2 incomers, and each incomer will have to be dragged under its own parent power source. For example, a transfer switch that accepts power from a generator and the second power source from Offsite power: SmartPlant Electrical Basic User’s Training Guide 181 Miscellaneous Features This will be presented in the SLD as follows: The following issues should be noted though: As these items are basically PDB’s, they are filtered out in SPEL load summary reports. Also, the All Feeders report and Batch load assignment will consider the Electrical Index circuits as being in a transparent mode, and the algorithm of the roll up will roll the connected loads downstream the incomers, provided the following property of the circuits are not set to Disconnected. Setting one of its incomers to Connected will turn the other incomer into connected, and vice versa. In case the circuit mode is in Disconnected mode, the roll up will stop and not drill down further. 182 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Some other notes: • Transfer switches will not be shown as possible PDB’s in the Feeder tabs and will be filtered out • In case a load is connected via a Transfer switch, the transfer switch name, its bus and outlet will be shown in the Feeder tab as the feeder of the load • The Batch load assignment will not account for a load connected via a transfer switch in Normal mode. In All feeder mode the transfer switch will act as regular PDB, and any load connected downstream via it, will be accounted for, provided circuits are not in “disconnected” mode. SmartPlant Electrical Basic User’s Training Guide 183 Miscellaneous Features Dual Power Source Equipment This feature is implemented to answer requirement of equipment that have 2 power sources, a Primary and an Alternate, as follows: Or: Or, The user needs to define a second or alternate power source for an electrical equipment by selecting the equipment in the electrical engineer, that has one main power source already defined: 184 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features This command will invoke a second Electrical engineer instance, from which user will select the alternate power source. The following conditions should be met for this operation to be successful: The equipment is not already connected to an alternate feeder The destination power source is a valid parent (power cable, feeder circuit, etc) Exercise: In this exercise we shall learn and accomplish the following: • How to connect a variable frequency drive to a main power source, coming from a VFD feeder circuit. • How to connect a second power source supplying the VFD from a power transformer. • Generate a single line diagram for this configuration. • How to dissociate the second power source. • Switching and modifying the second power source. Step 1 - Connect the VFD to the Main Power Source Create VFD-1 and drag it to under a feeder circuit via a power cable SmartPlant Electrical Basic User’s Training Guide 185 Miscellaneous Features Step 2 - Connect a Second, Alternate Power Source for VFD-1 Let us prepare a second power source for the VFD-1 by creating a new feeder branch from another bus through a transformer, as in the following picture: Right-click on VFD-1 and select “Add alternate power source..” : This will open a second instance of the Electrical Engineer that we shall use to navigate to the second power source: 186 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Select VFD Alternate source in the Alternate Power source engineer and click OK The result will be as follows: The “#” sign indicates that this is an alternate power source branch If we look at the VFD common properties: In the Feeder data tab: And in the Alternate Tab: SmartPlant Electrical Basic User’s Training Guide 187 Miscellaneous Features Step 3 - Generate an SLD for This Configuration For the dual power source equipment to show properly, a new symbol must exist for the item type, named as the original but with Alt added to the name. In our case it would be “VariableFrequencyDriveAlt.sym” Note: You may have to adjust the result to optimize the layout Step 4 - Change the Alternate Source In the electrical engineer, select the VFD-1 Feeder cable, right-click: This will open once more the Alternate Power source screen, and allow you to navigate to an alternate feeder: 188 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Step 5 - Dissociatie the Alternate Power Source Dissociation of the alternate power source is possible only at the final element itself, in our case, it is the VFD: Rules The following rules will apply: • Case A - Equipment has both Primary and Alternate power source and alternate is connected via a cable or a longer multi item branch The instance that connected to Primary power source can be dragged or dissociated as usual. All operations on the items with regards to his feeder will be assumed as operations on its Primary power source. To edit/change the Alternate Power source will be as follows: • The instance of "equipment" that is connected to an Alternate PS can only be dissociated in the engineer (the system will identify the Alternate power source from the Primary). User will have to select the item in the engineer and dissociate. The only place along the chain of the feeder that can be broken (dissociation taking place) by the user is the equipment itself and not any of its branch items. SmartPlant Electrical Basic User’s Training Guide 189 Miscellaneous Features • The "Cable" (or any item in the feeder chain), connecting between Alternate PS and "equipment" cannot be dissociated or dragged. • For re-connecting of the branch to another alternate PS the user will have to use again the response Engineer window. • Case B - Equipment is connected to alternate power source only, no Primary is connected "Equipment" and its "Cables or branch items" (if exists) are connected to Alternate Power Source only. • All actions that are not using the “Add Alternate power source” command will be interpreted by the system as regular operations on the Primary power source, so, Dragging "equipment" to any other branch will add a main power source, leaving alternate PS untouched. • Dragging or dissociating of "Cable" in an Alternate power source branch is not allowed. The "Cable" can be re-connected using response window. • Case C - Equipment has no power source at all, just connected to a feeder cable (after apply for example) "Equipment" doesn't have any feeding equipment but has a "parent Cable or something else". "Equipment" can be connected to Alternate PS using response window, "Cable" can be dragged to any valid power source creating a new main power source for the "Motor" Delete an Item that Feeds an Alternate Power Source The system does not allow you to delete an item that is in the path of the alternate power source feeding electrical equipment, only after the electrical equipment has been dissociated from its immediate upstream item that feeds it. Dissociate Alternate Power Sources The dissociation of the alternate power source will be also from the engineer, by the use of the “Dissociate” command. Dissociation will be possible only at the final element and not along any of its feeder items.. Dissociating primary source will not affect its alternate and vice versa. 190 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Rules in Operations that Involve Circuits All the operations and activities that deal with circuits on equipment will be acting on the main feeder and not on the alternate circuit. Associating an item to a alternate source The alternate source will not be required to match the last applied typical circuit of the item. Applying typical circuit Applying typical circuits on a dual input connected item will affect only its main feeder circuit, not the alternate circuit. Single line diagrams For the purpose of proper handling in the SLD, the dual input equipment would need to have a special symbol that will have 3 connection points, to handle both the 2 inputs ( loads, instruments and cabinets) and 2 inputs + one output for the converting equipment types. The 3rd connection point of the symbol will be dedicated for the Alternate Power source The SLD algorithm will position the dual input item so that its main feeder point will be positioned first, and the system will run the connector from its alternate feeder to the alternate connection point at the equipment. Load Summary reports Since the “All feeder report “ load summary may count the load twice in case the load is fed from 2 different user will have to disconnect the circuit by setting the Circuit mode parameter to disconnect. In case user doesn’t do that, the load summary will count the load twice. The drill down report will assume that circuit is connected unless CircuitMode=Disconnect Batch load assignment The batch load assignment, when operated in Normal mode (not drill down), will not count the load in case the circuit is feeding the load as alternate power source. The load will be accounted for in batch load assignment only for circuits that feed the loads as primary power sources. The All Feeder mode will take the load into account in both cases, provided the alternate power source feeder circuit is not in disconnected mode SmartPlant Electrical Basic User’s Training Guide 191 Miscellaneous Features Earth Loop Impedance Calculations in Cable Sizing The Earth loop impedance is defined as the total resistance seen by the source of current when clearing a faulty current to the earth. The earth loop impedance is an important safety factor since it determines what will be the highest possible potential at the point of the fault to earth. IEC regulations restrict this voltage to be no higher than 50 volts, therefore, EPC are requested to calculate this value on a per cable basis and make sure that the protective device for the circuit, fuse or circuit breaker protection values and settings are such that nor time nor earth potential will exceed codes, and will be able to clear the faulty current in a predetermined time. The calculation is done on a per cable basis and it includes both the cable armor earth impedance ( in case the armor is the earthling path) and any external to the cable impedance that is present from the power source through the final load and back to earthing point. The following illustration shows how a short circuit current flows through a earth fault: 192 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features In order to calculate the earth loop impedance user will select the Earth Loop Impedance tab of the power cable Common Properties: The calculation is based on the following formula: The calculation is the Electrical Index the based on the earth path formed by the cable armor metal sheet, or, of a separate grounding cable associated to the “to” side of the load. Any change in the cable grounding cable or properties Metering Equipment and Protection Relay In the Reference Data Explorer, under Metering Equipment within Disconnect Electrical Equipment: SmartPlant Electrical Basic User’s Training Guide 193 Miscellaneous Features Measure Transformers Current and Potential transformers, used to measure electrical current and voltage, may be created in the Reference Data Explorer and used in typical circuits: and Potential transformers: 194 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features These items, which are “in-line” items, can be used in typical circuits, measuring voltages and currents at specific points within the circuit: The physical configuration for such assembly of items would be: Changing the Tag sequence number of the transformer, changes the location at which the measurement is performed. Dragging the circuits to the Index will create the transformers accordingly. SmartPlant Electrical Basic User’s Training Guide 195 Miscellaneous Features The transformer ration is a calculated property, a string that identifies the actual ratio of the secondary with respect to the primary (2:1 would mean that for each 2 units of the primary variable, the output has 1 unit) Create Meters Thee could be 3 types of meters (readout devices) that can accept the outputs of the transformers: Voltmeter, Ampere-meters and Multi-meters, each with its own properties: 196 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features and the multi-meter, which is user configurable: Protection Relays and Relay Functions This item has been relocated from its previous location and moved to under the Metering equipment, and changed its functionality to match the new one. A protection relay is now a configurable device that could perform as a multiple functions protection device, as found in the industry. Such devices may range from simple Overcurrent trip relay, that its sole function is to measure the current flowing at a certain location and trip in case the current exceeds certain pre-set limit, to a combination of various functions. The following user may now predefine standard relay functions and use them to create protection relay functionality, as follows: This will allow creation of protection relays, using as many relay functions as needed: SmartPlant Electrical Basic User’s Training Guide 197 Miscellaneous Features Protection relays can be inserted in the Reference Data Explorer in typical circuits and applied in Index, as before. Drag Metering Equipment to the Instrument Index User may create metering equipment in the Index items as follows: • Loads • Converting equipment • Converting equipment components • Battery Banks • Generators • Of site power • PDB’s • Buses • Cells • Circuits • Disconnect electrical equipment • Transfer switches A new folder named Metering equipment contains the metering items under each class of items: 198 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Or by simply dragging them from the Reference Data Explorer: Metering equipment folders have been added to all the items as per the list above, except for circuits that will have these items as internals. The reason for that is since Meters and protection relays can be physically located separately from the circuits they serve, on the PDB front panel, within the cell, or elsewhere. Note • When inserted in circuits, metering equipment become circuit internals in all respects. However, please note the following: • Current and Potential transformers become inline internals, with regular Sequence in group functionality and will be shown in SLD as such. • Meters and Protection relays will become circuit internals but will have the Electrical Index InSld flag set to False and not be shown in the generated SLD drawing. The Meters and Protection relays, as they are not shown will have to be inserted manually, by the user into the generated opened SLD (see bellow) SmartPlant Electrical Basic User’s Training Guide 199 Miscellaneous Features Working with Metering and Protection Relay Symbols in the SLD The following workflow is recommended for this activity. 1. Create multi connection point symbol 2. Insert symbols in SLD 3. Connect between the items Create Symbols with Multiple Connection Points Add connection points to the existing symbols or create new symbols that you want to insert in the SLD (Protection relays). We will use the following examples to demonstrate the capabilities: • Protection relay: • IN1= Connection point 1 • IN2= Connection point 2 • OUT1=Connection point 3 • A circuit breaker The middle connection point is connection point 3 • A current transformer and potential transformer 200 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Let us now add them to the project. 1. Add potential and current transformer to a circuit: 2. Generate the SLD and concentrate on the circuit with the transformers: Insert the Protection Relay Symbol 1. Insert a Symbol From Menu-ÆEdit: SmartPlant Electrical Basic User’s Training Guide 201 Miscellaneous Features 2. Select the Protection relay with connections: 3. Position it near the transformers: 202 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features 4. To turn the connection points, click Edit -> Activate Connection Mode 5. Select a connection point until you see a red circle, click the left mouse button, then the second, select the red circle and click left mouse button: 6. Connect the output of the relay to the circuit breaker (make sure that the CB has a 3rd connection point). Adjust the dashed lines to suit the positioning restrictions SmartPlant Electrical Basic User’s Training Guide 203 Miscellaneous Features Cable Management System Automating Cable to Drum Assignment Let us create 2 drums, one for 4mm2 and second for 35mm2, 3 cores. At this point in time we shall do an automatic cable to drum assignment 204 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features This procedure can be automated using the following User Interface: Include assigned cables means that we wish to do a complete revamp in the design and start the assignment from scratch. This will result in first dissociation of the assigned cables from the Electrical Index drums. Create new drums will create new drums in case the operation fills up all existing drums and still cables are left to be assigned, otherwise, these cables will be left untouched waiting for new drums to be created manually Delete empty drums in case the auto assignment shuffles results in empty drums, they will be deleted Select all reference cables will handle all the cables of all types in the project, otherwise, only for the selected type of cable Select all pulling areas will perform the operation for all pulling areas, otherwise, only for the selected one. The algorithm works as follows: Based on the defined cable set ( all reference cables, include assigned cables), the system will organize them in an descending actual length order, from the longest cable down to the shortest, per cable type and per pulling area set, as defined in the check boxes options. The system will also set the same order to the existing drums of the same reference cable, starting from the drum that has the longest free cable available, to the shortest ( free cable on drum would mean the maximum cable on drum figure – total cable assigned to the drum, including spare). Then, the system will start, per pulling area and per cable type assigning the longest cable to the drum which has the longest free spare (provided it doesn’t exceed the maximum cable on drum figure) SmartPlant Electrical Basic User’s Training Guide 205 Miscellaneous Features Following the selection of set of cables the Wizard will find the cables and sort them: Note: Cables with no actual length or with no pulling areas cannot be selected and will not be processed. If data is missing for a cable do a right-click--ÆCommon Properties to edit the cable data. Selecting the cables and clicking the Next command: 206 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Cables have been assigned to corresponding drums, from the longest to the shortest. The system needs to accommodate and take into account that the actual cable on the drum must include the spare. Cable Routing The cable management supports the following activity: • Creation of a library of reference items for Trays, Conduits and Miscellaneous cableway components • Assignment of Project segments to reference cableway components • Defining Predefined cable routes • Connectivity of segments in between themselves • Assignment of cables to cableways using the following methods: SmartPlant Electrical Basic User’s Training Guide 207 Miscellaneous Features • Manual segment to cable assignment • Copying predefined routes to cables • Copying of one cable route to another cable • Batch cable routing using manual, copy route and copy from other cable route • Segregation level definitions and validations • Tray fill validation using the following basic rules: • Cableway component physical dimensions of width, Depth of tray and Diameter of conduits against cable physical dimensions and Fill factors • Weight per length properties of cableway component against total assigned weight per length of cables and Weight Fill factor. Exercise We will create 3 cableways, with the Electrical Index segments, specify tray types, defines predefined routes and perform cable routing, as per the following equipment layout: Step 1 - Create cableways infrastructure In the Index, select Wiring ÆCableways and create: Cableway “Blue”, “Pink” and “Violet” 208 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Right-click on the “Blue” cableway to create segments “BL-1” and “BL-2”, as follows: SmartPlant Electrical Basic User’s Training Guide 209 Miscellaneous Features 210 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features The reference component ‘Straight Run Tray’ is selected from the reference library. You need to create it in the reference data explorer. In the same way create the entire segments within the 3 cableways: SmartPlant Electrical Basic User’s Training Guide 211 Miscellaneous Features Step 2 - Create Predefined Routes Since we have 4 areas in which equipment is located, let us create 4 predefined routings, which we shall use later to route the cables to the motors. This will open the routing definition screen: 212 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Click New to create a new predefined route, R-1, from MCC to Area A (for motors M-3 and M-4): Click OK to confirm: SmartPlant Electrical Basic User’s Training Guide 213 Miscellaneous Features Repeat this procedure to create now the other routes, as follows: R-2, for MCC-1 to Area B R-3, for MCC-1 to Area C R-4, for MCC-1 to Area D 214 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features At this stage we should have the 4 predefined routing paths: Step 3 – Define the Cable Routing We should have in our project, already available, feeder cables for all the motors, as follows: For M-1, cable M-1 Feeder For M-2, cable M-2 Feeder For M-3, cable M-3 Feeder For M-4, cable M-4 Feeder For M-5, cable M-5 Feeder For M-6, cable M-6 Feeder For M-7, cable M-7 Feeder For M-8, cable M-8 Feeder SmartPlant Electrical Basic User’s Training Guide 215 Miscellaneous Features For M-9, cable M-9 Feeder According to the equipment layout, the cables should be routed as following: Cable Route M-1 Feeder R-2 M-2 Feeder R-2 M-3 Feeder R-1 M-4 Feeder R-1 M-5 Feeder R-3 M-6 Feeder R-3 M-7 Feeder R-4 M-8 Feeder R-4 M-9 Feeder R-4 Open the Tabular Editor: Select “Default cable List” layout And click OK. From the open table, select cables M-1 Feeder and M-2 Feeder 216 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Click Actions Æ Cables ÆBatch Cable Routing: The Batch Cable Routing dialog box opens with the 2 selected cables shown in the grid: SmartPlant Electrical Basic User’s Training Guide 217 Miscellaneous Features Select the Select predefined route radio button and then click Find: This operation opens the Find dialog box, and allow you to search for a predefined route. Click Find Now to find all the routes that match the specified segregation level: Select R-2 and click OK. Observe that the routing data of R-2 has been copied to the Cable routing grid area: 218 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features The following message is displayed: To make sure the cables have been routed, let us look at the cable common properties of M-1 Feeder: Notice that the cable actual length equals to the route: SmartPlant Electrical Basic User’s Training Guide 219 Miscellaneous Features Let us repeat the operation for the rest of the cables, as per the above table: M-3 Feeder and M-4 Feeder to R-1: Click OK to route the cables. M-5 and M-6 to R-3: 220 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features M-7 Feeder, M-8 Feeder and M-9 Feeder to R-4 SmartPlant Electrical Basic User’s Training Guide 221 Miscellaneous Features In the Cableways folder, select segment P-1 and right-click Common Properties: Select the Associated Cables tab and see that all the cables that have been routed via this segment: 222 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Step 4 - Generate a Segment Fill Report Let us now generate the segment fill report and see the loading of the segments. 1. In the Electrical Index, select the Cable Ways folder: 2. Click Reports -> Plant Reports. 3. Select the Segment Fill Report: 4. Save the report: SmartPlant Electrical Basic User’s Training Guide 223 Miscellaneous Features 5. Click Yes to save the output as an Excel file: The software generates the Excel report and includes the design data with the fill information: Cable Routing Validation Rules The following validations are carried out while performing cable routing: • Segregation level of the cables and route must match. • For segments of uncovered trays the tray fill validation validates that: The total allowable width (tray width times the fill factor) is greater than the total accumulated outside diameters of the cables assigned to the segment. • • For all other segments, the basis of the validation is on the allowable area of the segment is not less than the accumulated cables area. • Modifying cables outside diameter or weight per length of the cable will be validated against the segment fill • Modifying cableway width, depth, diameter or the tray cover will be validated against the segment fill. System will reject a property change that will result in overfill, unless, the “Allow overfill” flag is set. 224 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Step 5 - Copy Route from One Cable to Another In the Power cables folder, select cable M-1 Feeder and duplicate it: Rename it to M-1A Feeder, Right-click on the cable and chose Common properties: Select the Design Tab to perform the cable routing. In the Segregation level select Power. Select the Copy route from cable as shown below Click on the “Find” button and click again on the Find now: SmartPlant Electrical Basic User’s Training Guide 225 Miscellaneous Features From the Results grid, select M-1 Feeder and click the OK button to perform the cable routing. 226 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features Save Routing of a Cable as a Predefined Route Let us make now a change in the cable routing, by adding a segment and select The Save as New Route. That opens the Predefined routes dialog allowing you to save it as a new route: SmartPlant Electrical Basic User’s Training Guide 227 Miscellaneous Features Introducing NEC Motor Tables Data Once NEC Tables have been loaded into SPEL users may start using this data. This functionality allows the user to make use of the NEC Motor look up tables that are shipped within SPEL reference data. The tables are as following: The first 3 tables are provided so to populate the Full Load current property of motor current values as per the NEC, each with its own keyfields, for example: The last 2 Tables, 430-151(A) and 151(B) will populate Locked rotor values, according to the keyfields, including the new motor property called Motor Design Letter. Functionality: Apply of these FLA and LRC look up tables will be enabled and possible when user sets the Project Motors to “NEC”, the keyfields are populated and the FLA calculation mode is on “NEC Tables”. 228 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features In the Electrical Data tab folder: Defining the Lock rotor current for NEC motors The LRC currently is managed the Electrical Index the manually, or calculated by the FLA and the ratio LRC/FLA On NEC type of motors the LRC will be populated or calculated as per the following: Setting the LCR Code letter to True and selecting one of the available letters: According to the shown formula (AC motors only): SmartPlant Electrical Basic User’s Training Guide 229 Miscellaneous Features For single phase motors instead of 1.73, it will be 1. With the “Indicating code letter” un checked, the system will behave as per the following: the a value applied from the NEC Tables ( when all is set to NEC and NEC Tables is set at the FLA calculation mode calculated as per its FLA dependency, or manually entered The following summarizes the behavior of the FLA, LRC and the ratio: Full load current and locked rotor current Situations for Calculated mode 1. FLA will be always calculated automatically according to load data. 2. LRC or Ratio will be inserted by the user, the missing value will be calculated by the software. User must fill in 1 of 2 parameters. If inserting the LRC the ratio will filled in automatically. If inserting the ratio the LRC will be calculated automatically. Situations for Manual mode 1. The user must insert manually 2 of 3 parameters, the third parameter will be calculated by the software. If inserting FLA and LRC the ratio will be calculated by application. If inserting FLA and Ratio the LRC will be calculated by application. If inserting LRC and ratio the FLA will be calculated by application. 230 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features . Situation for NEC tables * 1. FLA will be filled in by apply NEC LUT, LRC will be filled in by apply NEC LUT, The application will automatically fill in the ratio. All fields are read only. 2. FLA will be filled in by Apply NEC LUT, LRC will be fill in automatically by selecting use locked rotor current and selecting indicating code letter, ratio will be fill in by application. All fields are read only. * Must have the NEC LUT imported to the project (plant). Motor conformity to standard must be set to NEC Note • The Used locked rotor current indicating code check box and the indicating code letter select list are enabled only for NEC table entries (in the override FLA calculation). Detailed Transformer Neutral Grounding Definitions The ability to define how the star point of the transformer is connected, what type of connection the transformer has with respect to its windings. SmartPlant Electrical Basic User’s Training Guide 231 Miscellaneous Features Defining the Neutral to Ground of the Transformer Windings This is what we want to achieve: Setting the Neutral grounding to None will disable the Grounding cable and Resistor data windows. Setting the Neutral grounding to Solid Grounding, enables to relate the transformer Y center with a grounding cable. 232 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features To relate a grounding cable you need first to select a free grounding cable and set its “Neutral grounding” new property to True: This will allow browsing and Find this cable from the Transformer form SmartPlant Electrical Basic User’s Training Guide 233 Miscellaneous Features Setting the Neutral to Impedance will enable the cable and also the Impedance data windows, which will now allow us to search for a NER (Neutral Earthing Resistor). 234 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features To associate a resistor, we need to define in a resistor the following data: Browsing to this resistor in the Transformer Connection and Tapping dialog box: The next new functionality deals with the definition of transformer tapings. By selecting the Tapping required check box enables you to enter data: The total tapping % is the product of the tapping % per step time’s the number of steps SmartPlant Electrical Basic User’s Training Guide 235 Miscellaneous Features The other new functionality is definition of the secondary winding connection related to the primary: The connection group defines the primary, secondary and the phase shift between them. D represents delta and Y represents star or Y. The number represents the phase shift in integers, each unit representing 30 degrees. The phase shift in degrees in this case will be 30x6=180 degrees phase shift. The “Winding fed from” defines if the phase shift is related to the primary or one of the secondaries. Representing the Neutral Grounding of the Transformer in an SLD Create a symbol for each of the components you may want to use to include the cable and resistance, or cable only in the Catalog Manager: The following transformer new attributes have been added for this purpose: For the grounding cable: 236 SmartPlant Electrical Basic User’s Training Guide Miscellaneous Features For the resistor: SmartPlant Electrical Basic User’s Training Guide 237 Document Revision History • Rev. 0. Initial Release of SmartPlant Electrical version 1.0.0.0. Basic Training Doc. #DELE2-TB-100001A (6/18/02) • Rev. 1 match to release 1.0.3.8 (8/06/02) • Rev. 2 match to release 1.0.4.5 • Rev. 3 match to release 01.05.00.08 (4/14/03) • Rev. 4 structure change and match to release 02.00.00.00 (09/03/03) • Rev. 5 Updates and enhancements to match version 03.00 (August 2004) • Rev.6 Updated for version 03.05.00.26 (September 2005) SmartPlant Electrical Basic User’s Training Guide 238