High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS
Transcription
High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS
High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS P/N# 240007518, Rev. D [10/2009] JACKET 3 5 8 10 9 7 6 4 1 11 Key 1 2 3 4 5 6 7 8 9 10 11 12 13 Description Complete Jacket Assembly Control Panel Hardware Bag Top Panel Right Panel Left Panel Front Panel Front Hinged Door Rear Panel, Upper Rear Panel, Lower Intermediate Support Plate - Upper Intermediate Support Plate - Lower Block Insulation Wrap* Block Insulation Rear* 4 section 240007118 240007123 550001937 240007310 240007319 240007327 240007337 240007314 240007331 240007333 240007334 240007335 240007339 240007338 (Same) = Same as 4 section. * = Not shown 2 240007119 5 section 6 section 240007120 7 section 240007121 (Same) (Same) (Same) (Same) (Same) (Same) 240007311 240007320 240007328 240007312 240007321 240007329 240007313 240007322 240007330 (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) 240007340 240007341 240007342 (Same) (Same) (Same) HEAT EXCHANGER 14 2 5 1 10 6 9 3 11 7 4 12 13 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Heat Exchanger Block Top Baffle V-Shaped Liner Stack (oval liner), 4 Section 1/4”NPT Plug Burner door with insulation & rope gasket Sight Glass Replacement Kit Door Hinge Kit (2 hinges included) Door insulation (hard)* (Front Door) Door Insulation (soft)* (Inner Burner Door) Target Wall Insulation* Door Rope Gasket* Flue Spacer Well in Block 4 Section 240007131 109007385 N/A 109007317 240005463 240007305 550001932 550001933 240007300 240007301 240007302 240007390 109007382 1635001 5 Section 240007132 109007386 N/A N/A (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) 6 Section 240007133 109007387 109007316 N/A (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) 7 Section 240007134 N/A 109007315 N/A (Same) (Same) (Same) (Same) (Same) (Same) (Same) (Same) N/A (Same) (Same) = Same as 4 section. * WARNING: This product contains fiberglass and/or ceramic fibers. Possible cancer hazard. To avoid this possible hazard, avoid breathing fiberglass wool & ceramic fiber dust. May cause irritation to skin, eyes & respiratory tract. 3 STANDARD CONTROLS & ACCESSORIES 2 1 3 17 4 5 14 8 6 16 7 9 10 Key 1a 1b 2 3 3a 3b 3c 3d 4 5 6 7 8 9 10 11 12 13 14 15 16 17 13 12 15 11 Description Barometric Draft Control, 5” (4 thru 6 section) Barometric Draft Control, 6” (7 Section only) Controls Manifold Aquastat Control Assembly (USA) Aquastat Control Wire Harness, Aquastat Wire Harness, Circulator Temperature Sensor (36” Assembly) 1 1/4” x 10” Nipple 1 1/4” x 6” Nipple 1 1/4” x 90° Elbow Drain Valve Relief Valve (30 PSI) Aquastat Mount & Plug 1/2”NPT Plug 3/4”NPT Plug 3/4” Street Elbow Parts Bag 24” Flexible Oil Line Burner attachment bolts - 5/16-18 X 3/4” LG Temperature / Pressure Gauge Well Clip Part Number 240007166 14620007 240007049 3001387 240007744 240007126 37519501 240007733 14607012 14607017 1190002 HW-016.02 VR-001.01 240007734 1395003 1395001 14693040 14684021 240007147 240007237 1260006 240008013 † = not shown 4 OIL BURNERS Replacement Burners Description Oil Burner - Beckett AFG w/ cover Oil Burner - Beckett AFG w/o cover Oil Burner - Beckett NX Oil Burner - Reillo F Oil Burner - Reillo BF (DV) 4 Section 240007144 240007232 240007531 240007502 240007528 5 Section 240007145 240007233 240007532 240007503 240007529 BECKETT BURNER REPLACEMENT PARTS - AFG & NX CAD Cell (AFG & NX) Power Cord (AFG & NX) Oil Pump Solenoid Pump, Oil Clinct #2184404U Beckett Burner cover Kit See Burner Manual for illustrations. When ordering, use the above part numbers. 6 Section 240007146 240007234 240007533 240007504 240007530 7 Section 240007183 240007235 N/A 240007505 N/A 14662085 240007129 RP04601 29688 240007393 BECKETT BURNER REPLACEMENT PARTS - AFG ONLY Combustion air tube with custom flange, 4 & 5 section Combustion air tube with custom flange, 6 & 7 section Igniter & Base Plate (Replacement Burner) Draw Assembly, 4 & 5 section (incl. 3-3/8U Static Plate & L2 head Igniter) Draw Assembly, 6 & 7 section (incl. 2-3/4M Static plate, V1 head Igniter) Burner Control, R7184P 1080 Burner Gasket with keyhole L2 Head (4 & 5 section) V1 Head (6 & 7 section) 3-3/8U Static Plate (4 & 5 section) 2-3/4M Static Plate (6 & 7 section) 240007638 240007639 1050007 240007640 240007641 240007642 240007392 240007645 240006446 BN08102 240007646 Beckett Burner Replacement Parts - NX ONLY Combustion air tube with custom flange, 4 & 5 section Combustion air tube with custom flange, 6 section Igniter & Base Plate Draw Assembly, 4 & 5 section (incl. Static Plate, Press Sensor Tube, Igniter, 6 Slot NX Head) Draw Assembly, 6 & 7 section (incl. Static Plate, Press Sensor Tube, Igniter, 9 Slot NX Head) Primary Burner Control (Pre 15S Post 2m) Burner Gasket with Keyhole Head/Leg Assembly, 6-slot NX, 4 & 5 section Head/Leg Assembly, 9-slot NX, 6 section Air Inlet Adapter, Modified Pressure Switch, 4 & 6 Section Pressure Switch, 5 Section Head Adjustment Mechanism Electrode Insulation Kit 240007772 240007773 240007774 240007775 240007776 240007777 240007778 240007779 240007780 240007781 240007782 240007783 240007784 240007785 5 REPLACEMENT PARTS Circulators Circulator - Grundfos UP15 Circulator - Taco NOZZLES 0.60 X 70B 0.65 X 60B 0.75 X 60B 0.75 X 45B 0.85 X 60B 1.00 X 45B 1.10 X 60B 1.25 X 45AS 1.35 X 60B CI-006.01 CI-001.03 nozzle mnf DELAVAN DELAVAN DELAVAN DELAVAN DELAVAN DELAVAN HAGO DANFOSS DELAVAN model no. NX 40BF3 40FS NX AFG NX AFG AFG 40F5 CONTROL PANEL PARTS Control Panel Assembly Power Switch,( SW,Rocker,12A,250V) Wire Harness, Control Panel to Burner Wire tie w/ mounting hole Bushing, Wire strain relief Terminal Block Ground Lug #10-32 x 1/2” Bolt #10-32 Hex Nut w/ star lock washer (Same) (Same) (Same) (Same) boiler size 4 SECTION 4 SECTION 5 SECTION 5 SECTION 5 SECTION 6 SECTION 6 SECTION 7 SECTION 7 SECTION (Same) (Same) part no. 1320025 14619058 14619244 240007742 14619024 240007740 240007737 240007738 240007741 3001377 240007176 240007178 240000062 14693011 212000014 212000015 201000047 202000004 6 KITS Description Low Water Cut Off Kit Low Water Cut Off LWCO Wire Harness Manual Reset Temperature Limit Kit Manual Reset Manual Reset Wire Harness Immersion Well Aquastat Assembly (Canada, for direct vent use 3001387) Aquastat Control Wire Harness, Aquastat to Control Panel Wire Harness, Aquastat To Circulator Wire Harness, Aquastat to Vent Safety Temperature Sensor (36” Assembly) 5” Vent Safety Kit (Required in Canada, USA optional) 5” Flue Connector Wire Harness Assembly, WMO Control Field 6” Vent Safety Kit (Required in Canada, USA optional) 6” Flue Connector Wire Harness Assembly, WMO Control Field Part Number 550001928 240007177 240007125 550001929 1010003 240007127 14662804 3001543 240007744 240007126 37519501 240004880 240007733 550001931 30655 240007547 30660 550001930 30656 240007547 30660 FOR DIRECT VENT UNITS ONLY Kit, Vent Flex, 4” dia x 10’ with Terminal adapter Kit, Vent Flex, 4” dia x 15’ with Terminal adapter Kit, Vent Flex, 4” dia x 20’ with Terminal adapter Terminal Adapter (part of Vent Flex kit) Vent Terminal Oil Riser Terminal (adds 36” height) Appliance Adapter 3 Pass Oil Boiler 240006909 240006910 240006911 240006914 28972 29231 240007535 7 For technical assistance with this product call toll free 1-800-325-5479 ECR International PO Box 4729 Utica, NY 13504-4729 www.ecrinternational.com 8