Daitsu Air-conditioner
Transcription
Daitsu Air-conditioner
Daitsu Air-conditioner ENGINEERING DATA split type air conditioner MODELS: ASD18UB Content 1.Description of product model coding and series introduction 2 . Specifications 3 . Curves of performance of compressor 4. Description, dimension and function of main components and accessories . 5 Knock-down drawings 6. Brief introduction to electrical control functions 7. Abnormity diagnose 8. Refrigerating cycle diagram DESCRIPTION OF PRODUCT MODEL CODING & SERIES INTRODUCTION 1 Description of product model coding and series introduction A.Standard Situation/Conditions WB C outdoor air status DBOC WBOC 27 C 19 OC 35 OC 24 OC Norminal heating 20 OC 15 OC 7 OC 6C Norminal electrical heating --- --- --- --- No. Operating condition indoor air status DBOC 1 Norminal cooling 2 3 O O O B.Series brief introduction 1.Protecting environment function The air conditioners use R410A as their refrigerant that can make the value of the ODP and GWP decrease greatly .so the environment can be protected better. 2.High energy efficient The design of inner-grooved copper tube greatly increases the refrigerant contact area and the efficiency of cooling/heating functions.Using the R410A refrigerant and the refrigerating system optimizing design make both the EER and COP reach the B class according to the european energy efficient standard. 3.Comfortable:wide-angle airflow The vertical dual-flap and horizontal wide-angle louvers ensure the cool/warm air reaches every corner of the room. 4.Health air purifying and negative ion function An air purifying filter with deodorizing and disinfecting functions keeps the air clean and users healthy.The negative ion generator can produce the negative ion that make the air fresher and cleaner 5.Quiet operation Fan with random-pitched blades. Random-pitched blades help reduce operating noise while maintaining a high airflow rate. 6.Convenience Auto restart and washable panel: The grille can be removed easily and washed when necessary.Any series have the function then even if the power falls when the unit is operating unit will automatically return to the operating settings in use before the power failure when power is restored. 7.Wide variety of functions 24-Hour Timer: 24-hour timer allows users to select the exact time they would like the air conditioner to turn on and to turn off.Timers on previous models operation based on the number of hours of desired operation. 2 Description of product model coding and series introduction 8.Night-set models When the air conditioner is operating on the timer-off circuit.The preset room temperature gradually rises(going down in heating)before the unit stops as shown below.Users can sleep comfortably without sudden change in temperature. 9.Program”dry” This function automatically reduces the level of humidity while maintaining the preset indoor temperature. 3 SPECIFICATIONS 4 Specifications Model: ASD18UB Cooling capacity(W) 4800 Heating capacity(W) 5200 Cooling coefficient(W/W) 2.91 Heating coefficient(W/W) 2.97 Cooling power input(W) 1650 Heating power input(W) 1750 1.9X10-3 Frequency range(Hz) 50 Operating voltage range(V) 220-230 ~ Refrigerant type Operating temp. range ( C) -7-43 Moiture removal(m3/h) Variation of temp. adjust ( C) +1 Air sending angle indoor unit Fan type outdoor unit Climate type: T1 Class of electric shock O O R410A 60 Cross flow fan Axial flow fan I Indoor unit noise( dB(A) ) (cooling) 45/42/37 Outdoor unit noise( dB(A) ) (cooling) 54 Indoor unit noise( dB(A) ) (heating) 44/41/37 Outdoor unit noise( dB(A) ) (heating) 55 Net dimensions ( mm) (indoor unit) Packaging dimensions ( mm) (indoor unit) Net/gross weight (kg) (indoor unit) Max. mounting height difference(m) Refrigerant charge(g) (R410A) Frequency of filter cleaning Compressor model Compressor oil charge (cc) Max . length of connecting pipe (m) Tube type 1013x331x277 11/14 heat Fan speed(r/min) (outdoor unit) Net dimensions ( mm) (outdoor unit) Packaging dimensions ( mm) (outdoor unit) Net/gross weight (kg) (outdoor unit) 1530 indoor unit outdoor unit Current entering side (indoor/outdoor) Once/2 weeks Max. refrigerant charge (g) RN196VHSMT Compressor manufacturer 520 Compressor protector type 5 20 TP2Y Fan speed(H/M/L)(r/min) cool (indoor unit) 938x182x265 1350/1150/950 1350/1150/950 820 Cut-off vavle(inch) two-way three-way 1/4 1/2 Max. operating pressure at warm side(Mpa) 4.15 Piling layers length(mm) diametre(mm) Type of tube of evaporator and condenser Size of tube of evaporator and condenser(mm) drain hose Appearance features of indoor unit Appearance features of outdoor unit Max. operating pressure at cool side(Mpa) 5 O 810x288x680 949x406x745 59/66 8 4 indoor 1580 MITSUBISHI internal 2000 16 Internal treaded O7&O9.52 plastic metal 4.15 CURVES OF PERFORMANCE OF COMPRESSOR 6 Curves of performance SIAM---ROTARY COMPRESSOR---MITSUBISHI 220V-50Hz-1 PHASE SUCTION GAS TEMP.---35ć UNDER COOL-----------8.3ć AMBIENT TEMP.---------35ć RUNNING CAPACITOR--40F MODEL: RN196VHSMT PERFORMANCE CURVE 45 50 55 60 FLOW RATE (kg/h) 110 100 90 80 70 60 50 -5 0 5 10 60 55 1700 50 1500 CONDENSING TEMP. (ć) INPUT ˄W ˅ 1900 45 1300 -5 0 5 10 CURRENT ˄A˅ 10.0 9.0 60 8.0 55 50 7.0 45 6.0 CAPACITY ˄W ˅ -5 0 5 6500 6000 5500 5000 4500 4000 3500 3000 2500 10 45 55 -5 0 5 EVAPERATING TEMP. (ć) 7 10 50 60 DESCRIPTION,DIMENSION AND FUNCTION OF MAIN COMPONENTS AND ACCESSORIES 8 Description and function of main components and accessories Indoor Unit For model: Test running switch (manual) Used only for test running in cooling when room temp is below16 .Don't use it in normal operation. Inlet grill ASD18UB Emergency switch(manual) Used when remote controller is lost or defective .Unit will run temporarily Air filter Remote signal receiver A beeping sound is generated when a signal from remote controller is received. Vertical flap Use remote controller to adjust up and down air flow. (Don't adjust it manually.) Power indicator Timer mode indicator Lights up when unit starts. Lights up when Timer operation is selected. Outdoor Unit For model: ASD18UB 9 Operation mode indicator Lights up during compressor running. Net dimensions for indoor unit and outdoor unit Net dimensions for indoor unit Net dimensions for outdoor unit 10 KNOCK-DOWN DRAWINGS 11 12 21 10 20 9 24 26 18 20 18 14 15 25 17 11 5 19 7 12 4 2 3 8 13 6 23 22 1 Knock-down drawings ASD18UB INDOOR UNIT Knock-down drawings ASD18UB NO. In exploded Name of part view INDOOR UNIT Parts code QTY. 0010802481 1 2 Controller assy. PCB 0010402025 1 3 PCB(receiver) --------- 1 4 Motor cover 001A1431717 1 5 Sensor 001A3900059 1 6 Transformer 001A3800065 1 7 Terminal block 001A4000122 1 8 Electricity power cord -------- 1 9 Front panel 001A0100943 1 10 Front grille 11 Rear case assy. 001A0100276 1 12 Service cover 001A1431494 1 13 Motor 001A3000088 1 14 Fan 0010202227 1 15 Bearing 001A0300005 1 16 Drain pan 001A0100460 1 17 Swing motor 001A3000008 1 18 Flap 001A1231140 1 19 Drain hose 001A0900011 1 20 Evaporator 0010705516 1 21 Air filter 001A2400080 2 22 Mounting plate 001A1301216 1 23 Piping support 001A1431368 1 24 001A1231139 1 25 Flap remote controller 0010401765 1 26 Negative ion generator 001A3100083 1 1 13 remark Knock-down drawings ASD18UB OUTDOOR UNIT 14 Knock-down drawings ASD18UB No. in exploded view 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 OUTDOOR UNIT Name of part Part code Front grille Front panel Fan Motor Motor support Heat exchanger Side panel assy.(L) Handle Top panel assy. Service cover assy. Side panel(R) Back grille 4-way valve 4-way valve coil Capacitor for comp. Capacitor for motor Electric box assy. Terminal block Pipe assy. Two-way stop valve Screw Three-way Stop valve Nut for fan Terminal cover Nut for compressor Compressor Rubber cushion Wires Bottom plate assy. Separating plate assy. Sound insulation cushion A Sound insulation cushion B 001A1303126A 001A1101038 001A2331024 0010402624 001A1301133 0010705512 001A0100356 001A1436182 001A0100124 001A0100125 001A0100126 001A1303128 0010703501 0010403102 001A3600131 001A3600018 0010803355 001A4000092 0010705526 0010705255 001A5002075 0010705372 001A5102021 0010203210 001A5102050 0010705170 0010203209 ———— 001A0100237 001A0100127 001A1762341 001A1762340 15 QTY. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 3 1 3 —— 1 1 1 1 BRIEF INTRODUCTION TO ELECTRICAL CONTROL FUNCTIONS 16 Brief introduction to electrical control function 17 Brief introduction to electrical control function 16 38 38 38 compressor four-way valve outdoor fan 18 Brief introduction to electrical control function 0 19 Brief introduction to electrical control function 20 Brief introduction to electrical control function 21 Brief introduction to electrical control function ABNORMALITY DIAGNOSING 22 Abnormality diagnosing For the abnormal phenomenon occurred, please conduct trouble analysis and troubleshooting according to the following table: No Reason of trouble Phenomena Remarks 1 The sensor of indoor ambient The compressor indictor temperature is in short circuit or and timing indicator broken circuit extinguish, and the running indicator flickers 2 The temperature sensor of The compressor indictor indoor coil pipe is in short and timing indicator are circuit or broken circuit on, and the running indicator flickers 3 Theindoormotoris damaged, or the The power indicator and The motor has no signal computer board is damaged running indicator of indoor feedback of Hall unit unit flicker twice , the power indicator, running indicator and timing indicator flicker togetherfor 1 second,then repeating the cycle. 23 24 REFRIGERATING CYCLE DIAGRAM 25 Refrigerating cycle diagram 26
Similar documents
DAITSU
The vertical dual-flap and horizontal wide-angle louvers ensure the cool(warm air reaches every corner of the room. 2.Health air purifying and negative ion function An air purifying filter with deo...
More information