Catalogue PDF
Transcription
Catalogue PDF
CIRCUIT PROTECTION SENTRY RANGE INTRODUCTION The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance mean it won’t look out of place when installed in hallways, lounges or kitchens of new properties. The expanded range includes a 21-module unit for larger installations and also a 4-module unit to cater for small one-off installations and extensions to existing ones. SUPPORTS 17TH EDITION AMENDMENT 3 COMPLIANCE Full range of products to support compliance with the 17th Edition Amendment 3 of the Wiring Regulations, including Full Metal non-combustible enclosures for Consumer Units. MK ELECTRIC DESIGN SERVICE FOR PRE-ASSEMBLED CONSUMER UNITS Save time and money by specifying project requirements through the MK Electric Design Service. Pre-assembled custom built boards, with all devices pre-fitted with busbars and cables are available to suit any installation. FLOATING BUSBAR SYSTEM Gives maximum installation flexibility. BROAD SELECTION OF PRE-ASSEMBLED SPLIT LOAD UNITS AVAILABLE Suits a variety of applications and saves installation time. HOW TO SPECIFY The MK Electric Design Service offers a preassembly service for custom built boards with all devices fitted, busbars cut and fitted with devices, live and neutral cables terminated. A metal range of consumer unit and accessories (Switch’s MCB’s, RCD’s & RCBO’s) designed to comply to the 17th Edition Amendment 3 of the wiring regulations (BS 7671:2008). Consumer unit doors must be top hinged to ensure the door is closed when the unit is not in use. The base, lid & door of the consumer unit must be earthed to provide safe operation at all times. A floating busbar system to be employed to ensure maximum installation flexibility and acceptance of control devices. All consumer units must have a curved door to prevent dust collection and offer a unobtrusive appearance that blends into the environment. Backed out captive screws, removable DIN rails and sufficient wiring space are required to ensure ease of installation and maintenance. MK Electric Catalogue 271 CIRCUIT PROTECTION Sentry mkelectric.co.uk MK Sentry Consumer Unit Features and Benefits NEW: Top Hinged Door Prevents door being left open after use leading to a possible fire risk NEW: Manufactured from Zintec Steel Corrosion resistant material which ensures full compliance with 17th Edition Amendment 3 NEW: Multiple extra large knock outs Aides and eases installation NEW: Continual Earthing Only need to earth once via the base Curved Stylish Design Broad Selection Available NEW: MK White Colour Modernised aesthetics for visible installations. Design service available for bespoke requests 272 mkelectric.co.uk Suits a variety of applications Blends into the environment Backed out and captive combi-head screws CIRCUIT PROTECTION Sentry Technical Hotline +44 (0)1268 563720 Fixing holes Allows simple and speedy installation Easily removable Din Rail Simplifying and easing first fix Tripod fixing to cope with uneven surfaces Colour coded earth and neutral terminal locked At top of unit for ease of wiring NEW: 10mm Increased Height Additional wiring space NEW: Supporting Din Rail “T” Bar Additional support to prevent bowing and twisting which has been raised for improved cable routing Floating busbar system For maximum installation flexibility including acceptance of control modules CONSUMER UNIT SELECTION GUIDE STEP 1 Determine the type of consumer unit configuration required. e.g Split Load, Standard or combination of split load / single RCD or dual RCD. For each Switch Disconnector or RCD to be used allow 2 modular ways. STEP 2 Determine the number of outgoing circuits required. e.g Cooker, Lighting, Ring Main etc. For each circuit to be protected by an MCB or RCBO allow 1 modular way. STEP 3 Determine what control products are required. e.g Bell Transformer, Time Delay Switch, contactors, timeswitches etc. STEP 4 Determine the number of ‘spare’ modular ways required for future upgrades. For each ‘spare’ modular way select 1 Sentry blank module – 5544s or K5545sMAG (cover mounted blanks supplied with consumer units. See page 286). STEP 5 Now add together the total number of modular ways required. STEP 6 Select from our range of Insulated, Metal, Flush or stacked consumer units (using standard consumer units plus stacking kits). Choose the type and size most appropriate for your requirements. Offset Incomer Provides additional wiring space making mains input connections easier MK Electric Catalogue 273 CIRCUIT PROTECTION Sentry mkelectric.co.uk The MK Electric Design Service THE MK ELECTRIC DESIGN SERVICE IS PERFECT FOR WHEN ONLY A CUSTOMISED SOLUTION CAN MEET YOUR REQUIREMENTS, OR WHEN FULLY ASSEMBLED CONSUMER UNITS CAN BE PROVIDED FOR YOUR PROJECT TO SAVE YOU INSTALLATION TIME. Our dedicated team can help you to build the best configurations for your project, and then assemble the boards ready for installation. Using standard and non-standard Sentry components we can build and supply fully assembled units to an agreed design. For example, have your split load boards supplied with all the devices pre-fitted with busbars and cables to suit the installation This service is ideal for housing developers, or any project application*. *Minimum order quantity of 20 of the same design • Dedicated team on hand to build configuration to meet your needs • Service is available for all MK Consumer Units • Faster installation time on site • Fast turnaround – 1 working day response time to initial enquiry To find out more visit www.mkelectric.co.uk and follow the links to the Design Service. 274 STEP 1 Call the MK Electric Technical Services Team on 01268 563720 or email [email protected] STEP 2 Discuss the details of your project and circuit protection requirements with a member of the MK Technical Services Team or complete the online enquiry and click send STEP 3 Within one working day you will have a response to your initial enquiry STEP 4 Confirm the configurations and quantities STEP 5 Receive the quote for your order STEP 6 Place your order with your wholesaler STEP 7 Your order will be delivered to the wholesaler of your choice. All boards will be fully assembled and ready for installation mkelectric.co.uk CIRCUIT PROTECTION Sentry Technical Hotline +44 (0)1268 563720 Consumer Units METAL ENCLOSURE + SWITCH DISCONNECTOR SURFACE METAL ENCLOSURE ONLY SURFACE K5704sMET K5604sMET K5716sMET K5616sMET K5708sMET K5608sMET K5621sMET K5721sMET K5712sMET K5612sMET K5604SMET1 4 WAY ENCLOSURE ACCEPTS 4 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR) K5608SMET1 8 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR) K5612SMET1 12 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (2 INTEGRAL NEUTRAL BARS FITTED WITH LINKS) All units are white coloured. All units feature a robust galvanized metal base, lid & door. The DIN rail embodies a useful alignment and fixing mechanism that allows quick installation. Cable entry points are located on top, bottom, side and rear surfaces. DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY Width 144 238 310 382 472 x x x x x Height 244 244 244 244 244 x x x x x K5616SMET1 K5704SMET1 K5716SMET1 K5621SMET1 K5708SMET1 K5721SMET1 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 19 ONE MODULE PRODUCTS 16 WAY ENCLOSURE ACCEPTS 16 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINKS) 21 WAY ENCLOSURE ACCEPTS 21 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINKS) 4 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 2 ONE MODULE PRODUCTS 8 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 6 ONE MODULE PRODUCTS 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 14 ONE MODULE PRODUCTS K5712SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3 Depth 116mm 116mm 116mm 116mm 116mm FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components All units are pre-fitted with a switch disconnector DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY Width 144 238 310 382 472 x x x x x Height 244 244 244 244 244 x x x x x Depth 116mm 116mm 116mm 116mm 116mm MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3 Cover mounted blanks are supplied with ALL consumer units (2 off x 1 for 4, 8 and 12 way enclosures and 2 off x 2 for 16 and 21 way enclosures) MK Electric Catalogue 275 CIRCUIT PROTECTION Sentry mkelectric.co.uk Consumer Units SPLIT-LOAD SINGLE RCD ARRANGEMENTS METAL SURFACE K5682sMET SPLIT-LOAD DUAL RCD ARRANGEMENTS METAL SURFACE K5662sMET K5666sMET K5687sMET K5682SMET 1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD ACCEPTS A FURTHER 8 ONE MODULE PRODUCTS K5662SMET 1 K5666SMET 1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS K5683SMET K5689SMET K5685SMET 1 K5688SMET 1 K5687SMET 1 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 80A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS K5684SMET 1 K5686SMET 1 K5681SMET 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD ACCEPTS A FURTHER 12 ONE MODULE PRODUCTS 1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 8 ONE MODULE PRODUCTS 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 12 ONE MODULE PRODUCTS 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 80A 30mA RCD ACCEPTS A FURTHER 17 ONE MODULE PRODUCTS All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded. MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY 276 Width Height Depth 144 x 244 x 116mm 8 WAY 238 x 244 x 116mm 12 WAY 310 x 244 x 116mm 16 WAY 382 x 244 x 116mm 21 WAY 472 x 244 x 116mm MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3 FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 80A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 1 X 63A & 1 X 80A 30mA RCD’S ACCEPTS A FURTHER 10 ONE MODULE PRODUCTS All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded. MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY Width Height Depth 144 x 244 x 116mm 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS 21 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 1 X 63A & 1 X 80A 30mA RCD’S ACCEPTS A FURTHER 15 ONE MODULE PRODUCTS 1 1 8 WAY 238 x 244 x 116mm 12 WAY 310 x 244 x 116mm 16 WAY 382 x 244 x 116mm 21 WAY 472 x 244 x 116mm MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3 Cover mounted blanks are supplied with ALL consumer units (2 off x 1 for 4, 8 & 2 way enclosures and 2 off x 2 for 16 & 21 way enclosures) CIRCUIT PROTECTION Sentry Technical Hotline +44 (0)1268 563720 FULLY POPULATED ARRANGEMENTS METAL SURFACE K6550sMET K7673sMET K6551sMET K7663sMET K7665sMET K6552sMET K7664sMET K7666sMET K7678sMET K6550SMET1 K7673SMET1 K6551SMET1 4 WAY ENCLOSURE 63A 30mA RCD 1 X MCB (1 X 50A) 4 WAY ENCLOSURE 63A 30mA RCD 2 X MCB’S (1 X 6A & 1 X 16A) K7663SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 63A 30mA RCD 6 X MCB’S (2 X 6A, 2 X 16A & 2 X 32A) 2 X RCBO’S (1 X 6A & 1 X 40A) K7664SMET1 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 6 X MCB’S (2 X 6A, 1 X 16A, 2 X 32A & 1 X 40A) All units are white coloured. All units are pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexibility of design allows the RCD to be positioned to suit the required configuration of RCD protected and non-protected circuits, subject to the rating of either the switch or RCD not being exceeded. 12 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 6 X RCBO’S (2 X 6A, 1 X 16A, 2 X 32A & 1 X 40A) ACCEPTS A FURTHER 4 ONE MODULE PRODUCTS K7665SMET1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 8 X MCB’S (2 X 6A, 2 X 16A, 3 X 32A & 1 X 40A) ACCEPTS A FURTHER 2 ONE MODULE PRODUCTS K7666SMET1 16 WAY ENCLOSURE 100A SWITCH DISCONNECTOR 2 X 63A 30mA RCD’S 10 X MCB’S (3 X 6A, 2 X 16A, 4 X 32A & 1 X 40A) MK recommends the use of RCBO’s for non RCD protected circuits to comply with the 17th Edition Amendment 3 Wiring Regulations. DIMENSIONS: 4 WAY 8 WAY 12 WAY 16 WAY 21 WAY Width 144 238 310 382 472 x x x x x Height 244 244 244 244 244 x x x x x Depth 116mm 116mm 116mm 116mm 116mm K6552SMET1 8 WAY ENCLOSURE 63A 30mA RCD 6 X MCB’S (3 X 6A, 1 X 16A & 2 X 20A) K7678SMET1 21 WAY ENCLOSURE 1 X 63A & 1 X 80A 30mA RCD’S 12 X MCB’S (3 X 6A, 2 X 16A, 2 X 20A, 4 X 32A & 1 X 40A) ACCEPTS A FURTHER 3 ONE MODULE PRODUCTS MAIN INCOMER RATING: 4 way enclosures: 63A 8, 12, 16 & 21 way enclosures: 100A Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. Use of cable glands and knockouts. BS EN 61439-3 FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components MK Electric Catalogue 277 CIRCUIT PROTECTION Sentry mkelectric.co.uk Consumer Units Switch Disconnectors Double Pole INSULATED SURFACE TWO MODULE K5604sMAG K5612sMAG 5500s K5608sMAG K5616sMAG K5621sMAG K5604SMAG1 4 WAY ENCLOSURE ACCEPTS 4 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR) K5608SMAG1 8 WAY ENCLOSURE ACCEPTS 8 ONE MODULE PRODUCTS (1 INTEGRAL NEUTRAL BAR) All units are magnolia coloured. All units feature a robust base together with an all over front cover and moulded lid in an impact resistant, flame retardant thermoplastic. Cable entry points are located on top, bottom, side and rear surfaces. DIMENSIONS: K5604sMAG K5608sMAG K5612sMAG K5616sMAG K5621sMAG Width 140 234 306 378 468 x x x x x Height 230 230 230 230 230 x x x x x Depth 110mm 110mm 110mm 110mm 110mm MAIN INCOMER MAXIMUM RATING K5604sMAG and K5504sMAG: 63A All other consumer units: 100A K5612SMAG1 12 WAY ENCLOSURE ACCEPTS 12 ONE MODULE PRODUCTS (2 INTEGRAL NEUTRAL BARS FITTED WITH LINK) K5616SMAG1 16 WAY ENCLOSURE ACCEPTS 16 ONE MODULE PRODUCTS (3 INTEGRAL NEUTRAL BARS FITTED WITH LINK) K5621SMAG1 21 WAY ENCLOSURE ACCEPTS 21 ONE MODULE PRODUCTS (4 INTEGRAL NEUTRAL BARS FITTED WITH LINKS) K5687SMAG17ED1 Degree of protection to BS EN 60529 to IP2XC. Precautions must be taken to maintain the IP rating, e.g. use of cable glands and knockouts. BS EN 60439-3:1999 FACTORY BUILT SERVICE: MK can save you time and money by pre-assembling consumer units with your required Sentry components 278 mkelectric.co.uk 5560s 5500s5 100A 230V 5560s5 63A 230V Suitable for installation in Sentry Consumer Units and two or four module enclosures. Accepts direct to busbar or cable-in / cable-out connection. CATEGORY OF DUTY: AC22A for switching of resistive and inductive loads. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 81 x 36 x 76mm CABLE CAPACITY: 50mm² BS EN 60947-3:1999 MCBs Single Pole MCB Single Pole TYPE B ONE MODULE TYPE C ONE MODULE 5903s 5910s 5906s 5916s CIRCUIT PROTECTION Sentry Technical Hotline +44 (0)1268 563720 5920s 5945s 5940s 8703s 8706s 8720s 8732s 8710s 8716s 8740s 8750s 5950s 5903s10 5920s10 20A 230V 3A 230V 8703s10 8720s10 5906s10 5925s10 8706s10 8725s10 5910s10 5932s10 8710s10 8732s10 5916s10 5940s10 8716s10 8740s10 3A 230V 6A 230V 10A 230V 16A 230V Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² Short-circuit breaking capacity: 6KA BS EN 60898:2003 25A 230V 32A 230V 40A 230V 5945s10 45A 230V 5950s10 50A 230V Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003 6A 230V 10A 230V 16A 230V Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003 20A 230V 25A 230V 32A 230V 40A 230V 8750s10 50A 230V 8763s10 63A 230V Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 83 x 18 x 74mm CABLE CAPACITY: 35mm² SHORT-CIRCUIT BREAKING CAPACITY: 6KA BS EN 60898:2003 MK Electric Catalogue 279 CIRCUIT PROTECTION Sentry mkelectric.co.uk RCBOs With Solid Neutral Single Pole Residential 6kA RCD Double Pole Type AC TYPE B ONE MODULE 7932s 16 AMP TWO MODULE TYPE C ONE MODULE 7933s 7934s 7935s 8932s 8933s 8934s 7816s 7936s 7937s 7932s1 6A 230V 30mA TRIPPING CURRENT 7933s1 10A 230V 30mA TRIPPING CURRENT 7934s1 16A 230V 30mA TRIPPING CURRENT Suitable for installation in Sentry Consumer Units. Positive contact status indication in accordance with 17th Edition IEE Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 119 x 18 x 73mm CABLE CAPACITY: Live 25mm², Neutral 25mm² SHORT CIRCUIT BREAKING CAPACITY: 6KA BS EN 61009-1 BS IEC 61009-2-2 280 mkelectric.co.uk 7938s 7939s 7935s1 20A 230V 30mA TRIPPING CURRENT 7936s1 32A 230V 30mA TRIPPING CURRENT 7937s1 40A 230V 30mA TRIPPING CURRENT 7938s1 45A 230V 30mA TRIPPING CURRENT 7939s1 50A 230V 30mA TRIPPING CURRENT 8935s 8936s 8932s1 6A 230V 30mA TRIPPING CURRENT 8933s1 10A 230V 30mA TRIPPING CURRENT 8934s1 16A 230V 30mA TRIPPING CURRENT 8935s1 20A 230V 30mA TRIPPING CURRENT 8936s1 32A 230V 30mA TRIPPING CURRENT 7816s1 16A 230V 30mA TRIPPING CURRENT 32 AMP TWO MODULE 7832s 7832s1 32A 230V 30mA TRIPPING CURRENT CIRCUIT PROTECTION Sentry Technical Hotline +44 (0)1268 563720 40 AMP TWO MODULE 63 AMP TWO MODULE 80 AMP TWO MODULE 7860s 7880s 7660s 7680s 7860s1 7880s1 7560s1 7580s1 7840s 7840s1 40A 230V 30mA TRIPPING CURRENT 63A 230V 30mA TRIPPING CURRENT 63A 230V 100mA TRIPPING CURRENT 7660s1 63A 230V 300mA TRIPPING CURRENT 80A 230V 30mA TRIPPING CURRENT 80A 230V 100mA TRIPPING CURRENT 7680s1 80A 230V 300mA TRIPPING CURRENT MK Electric Catalogue 281 CIRCUIT PROTECTION Sentry mkelectric.co.uk Industrial 10kA RCDs Double Pole Type AC 16 AMP TWO MODULE 32 AMP TWO MODULE 6016s 6032s 6316s 6730s 6016s1 6032s1 6416s1 6730s1 16A 110V 10mA TRIPPING CURRENT 16A 110V 30mA TRIPPING CURRENT 32A 110V 30mA TRIPPING CURRENT 32A 230V 30mA TRIPPING CURRENT 6316s1 16A 230V 10mA TRIPPING CURRENT 5716s1 16A 230V 30mA TRIPPING CURRENT 282 mkelectric.co.uk 40 AMP TWO MODULE 5740s 5740s1 40A 230V 30mA TRIPPING CURRENT 63 AMP TWO MODULE 80 AMP TWO MODULE 100 AMP TWO MODULE 5760s 6080s 6600s 5860s 5880s 7800s 5760s1 6080s1 7700s1 6160s1 5780s1 6600s1 5860s1 6180s1 7800s1 63A 230V 30mA TRIPPING CURRENT 63A 230V 100mA TRIPPING CURRENT 63A 230V 300mA TRIPPING CURRENT 80A 110V 30mA TRIPPING CURRENT 80A 230V 30mA TRIPPING CURRENT 80A 230V 100mA TRIPPING CURRENT 5880s1 80A 230V 300mA TRIPPING CURRENT 100A 230V 30mA TRIPPING CURRENT 100A 230V 100mA TRIPPING CURRENT 100A 230V 300mA TRIPPING CURRENT Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 36 x 75mm CABLE CAPACITY: 50mm² BS EN 61008:1995 Industrial 10kA RCDs Pulsating d.c. Fault Current Sensitive Double Pole Type A Industrial 10kA RCDs Time Delayed Double Pole TWO MODULE TWO MODULE 6216s 5640s 6980s 6630s 6216s1 16A 230V 10mA TRIPPING CURRENT 6630s1 32A 230V 30mA TRIPPING CURRENT 5640s1 40A 230V 30mA TRIPPING CURRENT 5660s1 63A 230V 30mA TRIPPING CURRENT Suitable for installation in Sentry Consumer Units and two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 36 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995 CIRCUIT PROTECTION Sentry Technical Hotline +44 (0)1268 563720 Industrial 10kA RCDs Four Pole Type AC 25 AMP FOUR MODULE 6425s 80A 230V 100mA TRIPPING CURRENT TIME DELAYED 6400s1 100A 230V 100mA TRIPPING CURRENT TIME DELAYED Suitable for installation in Sentry Consumer Units and Four Module enclosures. When used as a mains incomer these units will provide discrimination with downstream instantaneously operating 10mA or 30 mA RCD’s. For example, they can be used as main incomers on split load consumer units where it is not desirable, because of the possibility of unwanted tripping, to place all of the circuits on an instantaneous 30mA RCD, but where earth leakage protection is still required for these circuits or where compliance is required to the indirect contact protection requirements of the IET Wiring Regulations. 6440s 6240s 6400s 6980s1 40 AMP FOUR MODULE 6425s1 25A 230/400V 30mA TRIPPING CURRENT Suitable for installation in Sentry four module enclosures and Commando Combi. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 72 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995 6440s1 40A 230/400V 30mA TRIPPING CURRENT 6240s1 40A 230/400V 100mA TRIPPING CURRENT DIMS: 81 x 36 x 76mm CABLE CAPACITY: 50mm2 BS EN 61008:1995 NOT TO BE USED FOR PERSONAL PROTECTION AGAINST ELECTRIC SHOCK FACTORY BUILT SERVICE MK can save you time and money by pre-assembling consumer units with your required Sentry components MK Electric Catalogue 283 CIRCUIT PROTECTION Sentry Industrial 10kA RCDs Four Pole Type AC 63 AMP FOUR MODULE 6463s mkelectric.co.uk Industrial 10kA RCD Contactors Pulsating d.c. Fault Current Sensitive, Four Pole Type A FOUR MODULE 6640s 6363s 6463s1 63A 230/400V 30mA TRIPPING CURRENT 6363s1 63A 230/400V 100mA TRIPPING CURRENT 6263s1 63A 230/400V 300mA TRIPPING CURRENT 6640s1 40A 230/400V 30mA TRIPPING CURRENT Suitable for installation in Sentry two or four module enclosures. Positive contact status indication in accordance with 17th Edition IET Wiring Regulations (537.2.2.2 and 537.3.2.2) DIMENSIONS: 85 x 72 x 75mm CABLE CAPACITY: 50mm2 BS EN 61008:1995 ONE MODULE TWO MODULE THREE MODULE 6220s 7240s 7440s 6720s 7263s 7463s 20A DOUBLE POLE 20A FOUR POLE 6420s1 7440s1 6720s1 7240s1 7463s1 6220s1 20A DOUBLE POLE WITH MANUAL OVERRIDE Suitable for installation in Sentry Consumer Units and two or four module enclosures. Automatically switches higher loads than possible with a time switch eg; off peak tariffs. A manual override enables the temporary setting of the contactor in either the on or off position in addition to normal automatic operation. When a contactor is mounted alongside an MCB of greater than 10 amp current rating or two contractors are mounted alongside an MCB or side by side, it is necessary to insert a blank module between them (list no.5544s) 40A DOUBLE POLE 40A FOUR POLE 63A FOUR POLE 7263s1 63A DOUBLE POLE CONTACTOR RATINGS: List no 6220s 6420s 6720s 7240s 7440s 7263s 7463s RATED CURRENT Ith 20A 40A 63A 5.4kW 16kW 8.6kW 26kW 13.6kW 41kW 1.1kW 4kW 2.2kW 7.5kW 4kW 11kW 2,800W 2,000W 7,000W 4,200W 10,000W 6,300W VOLTAGE RATING (coil) 230V 50Hz 230V 50Hz 230V 50Hz CABLE CAPACITY 6mm2 rigid 25mm2 rigid 25mm2 rigid 6220S: 84 x 18 x 66mm 7240S: 84 x 36 x 66mm 7463S: 84 x 54 x 66mm 6420S: 84 x 36 x 66mm 7263S: 84 x 36 x 66mm 6720S: 84 x 18 x 66mm 7440S: 84 x 54 x 66mm HEATING Single phase 230V Three phase 400V MOTORS Single phase 230V Three phase 400V LIGHTING Incandescent and Halogen lamps: Fluorescent Lamps: (Electronic Ballast) BS EN 61095 DIMENSIONS: 284 mkelectric.co.uk (including half module blank) Bell Transformer TWO MODULE 5711s CIRCUIT PROTECTION Sentry Technical Hotline +44 (0)1268 563720 Time Switches DIGITAL ONE CHANNEL TWO MODULE DIGITAL ONE CHANNEL ONE MODULE SYNCHRONOUS THREE MODULE QUARTZ STABILISED THREE MODULE SYNCHRONOUS ONE MODULE 5707s 5824s 5833s 5731s 5733s 5732s 5824s1 5833s1 5731s1 5733s1 5732s1 Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures. Power reserve 150 hours VOLTAGE RATING: 220-240Va.c. 50-60Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 85 x 54 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993 Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures VOLTAGE RATING: 240V 50Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 90 x 18 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993 Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment, holiday programme and random generator are standard facilities. Power reserve of 150 hours. Suitable for DIN rail mounting in Sentry Consumer Units and two or four module enclosures VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 90 x 18 x 74mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993 Pre-programmed with UK time and automatic summer/winter adjustment. Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment. Power reserve of 3 years. Suitable for DIN-rail mounting in Sentry Consumer Units and two or four module enclosures. VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 85 x 36 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993 DIGITAL TWO CHANNEL TWO MODULE 5724s 5711s1 RATING 1A AT 8V PRIMARY 220 – 240V A.C.50HZ Suitable for installation in Sentry Consumer Units and two or four module enclosures. NOTE: When installed in a consumer unit, ensure that output cables inside the enclosures are suitable for a 230V environment, either by sleeving the bell wire to BS 2848 or using 230V cable. Complete with terminal covers. Also suitable for surface mounting. DIMENSIONS: 88 x 36 x 67mm CABLE CAPACITY: 1 x 2.5mm2 EN 61558-2-8 5707s1 7 DAY DIAL MIN SETTING 3 HOURS 5724s1 24 HOUR DIAL MIN SETTING 30 MINUTES Suitable for DIN rail mounting in Sentry Consumer Units or four module enclosures. VOLTAGE RATING: 220-240Va.c. 50Hz CURRENT RATING: Resistive load 16A Inductive load 4A Tungsten lamps 6A (1350W) Fluorescent lamps 1350W DIMENSIONS: 85 x 54 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 24 HOUR DIAL MIN SETTING 30 MINUTES 24 HOUR DIAL MIN SETTING 30 MINUTES 24 HOUR/7 DAY DISPLAY MIN SETTING 1 MINUTE Pre-programmed with UK time and automatic summer/winter adjustment. Provides 50 programming selections. Freely selectable day grouping facility. Manual override, winter/summer time adjustment. Power reserve of 3 years. Suitable for DIN-rail mounting in Sentry Consumer Units and two or four module enclosures. VOLTAGE RATING: 240V 50/60Hz CURRENT RATING: Resistive load 16A Inductive load 2.5A Tungsten lamps 5A (1000W) Fluorescent lamps 1000W DIMENSIONS: 85 x 36 x 68mm CABLE CAPACITY: 2 x 2.5mm2 or 4 x 1.5mm2 EN 60730-2-7:1993 24 HOUR DIAL MIN SETTING 1 MINUTE 24 HOUR/7 DAY DISPLAY MIN SETTING 1 MINUTE MK Electric Catalogue 285 CIRCUIT PROTECTION Sentry Time Delay Switches mkelectric.co.uk Consumer Unit Cable Kits Accessories ONE MODULE PUSH LEVER UP TO SWITCH ON RCBO TEST BUTTON PUSH LEVER UP TO SWITCH ON 10 11 12 13 14 15 16 18 19 20 21 22 23 24 2 14 RCD PROTECTED CIRCUITS RCD PROTECTED CIRCUITS TEST QUARTERLY TEST QUARTERLY 3 4 5 6 17 18 7 8 19 20 9 10 SWITCH 1 2 3 9 17 4 5 10 11 12 13 18 19 20 21 RCD PROTECTED CIRCUITS 1 2 14 (Cut as required) 12 13 22 23 24 15 U1 16 U2 SOCKETS GROUND FLOOR SOCKETS FIRST FLOOR K8041s K5545sMAG 24 TEST QUARTERLY 4 5 6 17 18 7 8 19 20 9 10 21 LIGHTS OUTSIDE RING CIRCUIT KITCHEN RING CIRCUIT SECURITY OUT ALARM BUILDING 220-250V 50Hz a.c. 220-250V 50Hz a.c. SHOWER SHOWER SECURITY ALARM RATED CURRENT MUST NOT EXCEED 63A MAX RATED CURRENT MUST NOT EXCEED 100A MAX SMOKE ALARM CLEAN EARTH DOOR BELL 4 module unit CENTRAL HEATING FRIDGE COOKER COMPUTER SMOKE ALARM LIGHTS KITCHEN SOCKETS LIGHTS GARAGE SOCKETS GARAGE LIGHTS ALL MAIN SWITCHES MUST BE SWITCHED OFF TO COMPLETELY DISCONNECT THE UNIT FROM THE SUPPLY DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3 12 13 22 23 24 15 U1 16 U2 U3 H Main Switches Warning Labels ON IMPORTANT SOCKETS LIGHTS SECOND FLOOR RING CIRCUIT SECOND FLOOR RING CIRCUIT FIRST FLOOR WATER HEATER SOCKETS WARNING SOCKETS SECOND FLOOR LIGHTS GROUND FLOOR RING CIRCUIT GROUND FLOOR WATER HEATER (Cut as required) 11 ON STORAGE STORAGE HEATER HEATER LIGHTS BASEMENT RING CIRCUIT BASEMENT FREEZER LIGHTS FIRST FLOOR 21 H Main Switches Warning Labels OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3 WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER SOCKETS BASEMENT SOCKETS GROUND FLOOR SOCKETS FIRST FLOOR LIGHTS OUTSIDE RING CIRCUIT KITCHEN RING CIRCUIT SECURITY OUT ALARM BUILDING 220-250V 50Hz a.c. 220-250V 50Hz a.c. SHOWER SHOWER SECURITY ALARM RATED CURRENT MUST NOT EXCEED 63A MAX RATED CURRENT MUST NOT EXCEED 100A MAX SMOKE ALARM CLEAN EARTH DOOR BELL 4 module unit CENTRAL HEATING FRIDGE COOKER COMPUTER SMOKE ALARM K5597s LIGHTS KITCHEN SOCKETS LIGHTS GARAGE SOCKETS IMPORTANT SOCKETS LIGHTS SECOND FLOOR RING CIRCUIT SECOND FLOOR RING CIRCUIT FIRST FLOOR WATER HEATER SOCKETS WARNING SOCKETS SECOND FLOOR LIGHTS GROUND FLOOR RING CIRCUIT GROUND FLOOR WATER HEATER LIGHTS FIRST FLOOR ON STORAGE STORAGE HEATER HEATER LIGHTS BASEMENT RING CIRCUIT BASEMENT FREEZER 8, 12, 16 & 21 module units This proof has been printed on a low resolution colour proofer. Colours may vary from final print. Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved. 5650s 8 16 23 RCD PROTECTED CIRCUITS 3 G Individual Circuit Labels 5544s 7 15 22 TEST QUARTERLY F Circuit ID Labels U3 RCD TIME DELAYED 11 ON 5562s 6 14 RCD PROTECTED CIRCUITS TEST QUARTERLY MAIN SWITCH F Circuit ID Labels SOCKETS BASEMENT B RCD 'TEST' Label Fit to prominent position on or near Consumer Unit. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RCD TIME DELAYED 1 RCBO TEST BUTTON RCD ADDITIONAL INFORMATION 8 TEST QUARTERLY PUSH LEVER UP TO SWITCH ON PUSH LEVER UP TO SWITCH ON Pantone 355 CIRCUIT NUMBER 7 RCD PROTECTED CIRCUITS Pantone Black E Additional Information Label 6 A RESETTING INSTRUCTION LABEL ADDITIONAL INFORMATION 5 CIRCUIT NUMBER 4 MAIN Mid-Trip Off Pantone 102 Pantone Blue?? If any device still switches off (or if the RCD cannot be switched on with all MCB's switched off) then call a qualified electrician, or for general guidance, MK Technical Services on 01268 563720. 3 E Additional Information Label 9 17 TEST BUTTON On MCB RCD • Reset the lever to the off position, if necessary. • Push the lever up, to switch on. • If the RCD trips again, switch off all MCB's & switch on the RCD. • Switch each MCB on, one at a time. the RCD will switch off when the faulty circuit is reconnected. Pantone 485 This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test quarterly by pressing the button marked 'T' or 'Test'. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice. RESETTING INSTRUCTIONS If a device switches 'OFF' in the event of a fault, take the following action: MCB / RCBO • Check each appliance connected to that device and remove if faulty. • Push the lever up, to switch on. • Under fault detection the MCB will trip to a mid-"trip" position. Reset MCB by switching "off", then "on". Reset RCBO by switching to "on". B RCD 'TEST' Label Fit to prominent position on or near Consumer Unit. RCD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 MK Electrics 22852 F641 25.03.08 v. 2 228.6 x 320 SENTRY CONSUMER UNIT - LABEL SHEET Please leave any unused labels with the consumer If any device still switches off (or if the RCD cannot be switched on with all MCB's switched off) then call a qualified electrician, or for general guidance, MK Technical Services on 01268 563720. A RESETTING INSTRUCTION LABEL 1 Ref: Ono: Our Ref: Date: Version: Size: WARNING Pantone 355 GARAGE LIGHTS DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER ALL MAIN SWITCHES MUST BE SWITCHED OFF TO COMPLETELY DISCONNECT THE UNIT FROM THE SUPPLY OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3 OFF MK SENTRY CONSUMER UNIT TO BS EN 60439-3 WARNING DISCONNECT THE MAINS SUPPLY BEFORE REMOVING THIS COVER 8, 12, 16 & 21 module units G Individual Circuit Labels This proof has been printed on a low resolution colour proofer. Colours may vary from final print. Liability cannot be accepted by PPL for errors or omissions once the proof and job specification has been approved. K5599s K5563s K6061SMET K5511s 5650s1 DELAY RANGE 1 - 7 MINUTES (APPROX) Suitable for installation in Sentry Consumer Units and two or four module enclosures. Offers time delay control for complete circuits of either tungsten or fluorescent lighting with any number of standard push switches. It can also be used to control fans in bathrooms without a window. Delay setting can be over-ridden by setting to ‘Perm-on’ mode, or by fitting a remote overriding switch. Switch has a switching capacity of 16A Resistive loads (upf) Fluorescent lamps uncompensated Series compensated 1300W Parallel compensated 480W CFLS 100W Max. Maximum of 9 units can be connected Incandescent lamps 2000W Neon glow lamp load (locating lamp for Push Switch) 50mA max VOLTAGE RATING: 230V 50Hz DIMENSIONS: 84 x 18 x 70mm CABLE CAPACITY: 1 x 4mm2or 2 x 1.5mm2 286 mkelectric.co.uk K5565s K5593s KAX26s K6062SMET K5563s5 5562s1 5544s5 K5597s5 SPLIT-LOAD KIT CONSISTS OF 3 CABLES (2 NEUTRAL AND 1 LIVE) FOR USE WHEN ASSEMBLING A SPLIT LOAD ARRANGEMENT K5565s5 MULTI-INCOMER KIT CONSISTS OF A BLUE FLEXIBLE CABLE WITH PRE-FITTED TERMINAL FOR THE NEUTRAL RETURN FROM SWITCH OR RCD TO SECOND OR THIRD NEUTRAL BAR K5568s5 17TH EDITION CABLE KIT FOR SWITCH AND TWIN RCD ARRANGEMENT K5567s5 A&D CABLE KIT FOR SWITCH PLUS TRIPLE RCD ARRANGEMENT K5563S For use when assembling split-load arrangement. K5565S For use when assembling a consumer unit in a multi-incomer arrangement with separate supply to each incomer. These kits must be used to ensure compliance with BS EN 60439-3 EXTENSION TERMINAL FOR USE WHEN ASSEMBLING A CONSUMER UNIT AS A DISTRIBUTION BOARD. ENABLES DIRECT CONNECTION OF CABLES TO THE NEUTRAL BAR. CONSISTS OF A 25MM2 CAPACITY TERMINAL WITH CLAMP SCREW K8041s10 LOCKING DEVICE FOR USE WHEN LOCKING A SENTRY MCB, RCBO, RCD OR SWITCH DISCONNECTOR IN EITHER THE ON OR OFF POSITION K5593s BARREL LOCK AND KEY KIT SUITABLE FOR SECURING ‘K’ SERIES SENTRY CONSUMER UNIT LIDS. ONLY SUITABLE FOR HYBRID AND INSULATED CONSUMER UNITS 1 MCB BLANK – GREY DESIGNED TO FILL UNUSED MODULES IN SENTRY CONSUMER UNITS AND SMALL ENCLOSURES. DIN-RAIL MOUNTED K5545sMAG10 COVER MOUNTED BLANK FOR FILLING SPACES IN THE ‘K’ SERIES SENTRY CONSUMER UNIT COVER, WHERE THERE ARE UNUSED MODULES K5511s1 BUSBAR 11 MODULE K5590s1 BUSBAR 20 MODULE KAX26s10 BUSBAR COVER SUITABLE FOR INSULATING THE BUSBARS K5511S AND K5590S 20 MODULE. ONLY SUITABLE FOR HYBRID AND INSULATED CONSUMER UNITS ENSURE ALL TERMINAL SCREWS ARE FULLY TIGHTENED BEFORE FITTING FRONT COVER Mid-Trip Off Pantone Black C Busbar Shield Warning Label (Factory fitted) TEST BUTTON On MCB RCD • Reset the lever to the off position, if necessary. • Push the lever up, to switch on. • If the RCD trips again, switch off all MCB's & switch on the RCD. • Switch each MCB on, one at a time. the RCD will switch off when the faulty circuit is reconnected. Pantone 102 Pantone Blue?? WARNING RESETTING INSTRUCTIONS If a device switches 'OFF' in the event of a fault, take the following action: MCB / RCBO • Check each appliance connected to that device and remove if faulty. • Push the lever up, to switch on. • Under fault detection the MCB will trip to a mid-"trip" position. Reset MCB by switching "off", then "on". Reset RCBO by switching to "on". Pantone 485 This installation, or part of it, is protected by a device which automatically switches off the supply if an earth fault develops. Test quarterly by pressing the button marked 'T' or 'Test'. The device should switch off the supply and should then be switched on to restore the supply. If the device does not switch off the supply when the button is pressed, seek expert advice. ENSURE ALL TERMINAL SCREWS ARE FULLY TIGHTENED BEFORE FITTING FRONT COVER MK Electrics 22852 F641 25.03.08 v. 2 228.6 x 320 SENTRY CONSUMER UNIT - LABEL SHEET Please leave any unused labels with the consumer C Busbar Shield Warning Label (Factory fitted) Ref: Ono: Our Ref: Date: Version: Size: CONSUMER UNIT LABELS ADDITIONAL PRINTED AND BLANK LABELS, FOR IDENTIFYING DEVICES AND CIRCUITS ON DUAL & TRIPLE RCD BOARDS K5599s5 CONSUMER UNIT LABELS ADDITIONAL PRINTED AND BLANK LABELS, FOR IDENTIFYING DEVICES AND CIRCUITS ON SINGLE RCD BOARDS K5804sD1MAG K5808sD1MAG K5812sD1MAG K5816sD1MAG K5821sD1MAG REPLACEMENT PLASTIC FRONT COVERS K6060SMET1 16 WAY METAL CONSUMER UNIT SURFACE MOUNTING KIT K6061SMET1 12 WAY METAL CONSUMER UNIT STACKING KIT K6062SMET1 16 WAY METAL CONSUMER UNIT STACKING KIT ASPECT DOUBLE SOCKET – BESPOKE FINISH Available on a worldwide basis, the MK Design Service is supported by a dedicated team to ensure the seamless delivery of your chosen products. To find out more visit www.mkelectric.co.uk MK Electric Catalogue 287 PRODUCT APPLICATION PRODUCT APPLICATION