Fans for transformer cooling 2CT2 10
Transcription
Fans for transformer cooling 2CT2 10
Technical Assistance Tel.: +49 421 5125 316 Fax.: +49 421 5125 635 Email: [email protected] mdexx Fans for transformer cooling Introduction 1 Quick Selection 2 2CT2 44 3 2CT2 56 4 2CT2 63 5 2CT2 73 6 2CT2 80 7 2CT2 10 8 2CT1 16 9 Catalog · 2010 Valid from 10/2009 Annex The products listed in this product brochure are manufactured in compliance with a TÜV-certified quality management system in accordance with DIN EN ISO 9001 (certificate registration number 12 100 36376 TMS). The TÜV certificate is acknowledged in all IQ Net countries. TÜV stands for German Technical Control Board. 10 Niederspannungs-Schalttechnik Notes Packaging size (PS) The packaging size defines the number of units, sets or meters, for example, for outer packaging. Only the quantity defined by the packaging size or a multiple thereof can be ordered! Dimensions All dimensions in mm. Dimensions are approximate indications. Similar illustrations. Informationen More information about fans can be found on the Internet at http://www.mdexx.com. If you have any questions, please send an e-mail to: [email protected]; [email protected] or fax: +49 (0)421/5125 635. 2 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Introduction 1/2 mdexx 1/4 mdexx fans develops and produces transformers, power supplies, reactors and filters – as catalogue products and customer-specific versions – as well as axial and radial fans for tailor-made ventilatory solutions. Decades of experience, highly qualified employees in the development and construction sectors and the latest measuring and testing equipment guarantee our customers the highest quality possible. mdexx produces at the most modern sites in Germany, the Czech Republic and China, using sophisticated quality and environmental management systems. mdexx products represent absolute reliability, a maximum of functionality and innovation, subject to international regulations. 1/2 mdexx fans for transformer cooling - 2010 Highly qualified employees in the development and construction sectors and the latest measuring and testing equipment guarantee that mdexx products always fulfil the highest quality demands. New developments are tested on over 1000 square metres of laboratory space, where type tests in accordance with national and international norms and systems, ageing and material tests are carried out. Throughout all branches, unique in Europe! We measure quality and success by the extent to which our products and solutions fulfil our customers’ demands. The entire quality strategy of mdexx Magnetronic Devices is aligned to their high standards regarding functionality, performance and price. To support this quality strategy we are certified in accordance with DIN ISO 9001:2000; DIN EN ISO 14001; DIN EN ISO/EC 17025-2005 and DIN EN 15085-2/CL1. Our products are certified in accordance with: DIN; EN; UL/CSA; VDE. We adhere to the building regulations of the leading classification societies: ABS (American Bureau of Shipping); DNV (Det Norske Veritas); GL (Germanischer Lloyd); BV (Bureau Veritas); PRS (Polski Rejestr Statkow). mdexx fans for transformer cooling - 2010 1/3 mdexx fans Whether used in the electrical industry, or for cooling power transformers or drives mdexx fans have been meeting cooling and ventilation requirements reliably for many years. Our wide range includes particularly lownoise fans with optimized efficiency, for use in a wide variety of applications: from rugged low-pressure axial fans to medium-pressure axial fans that can be used flexibly, through to highly efficient medium-pressure radial fans. Whatever your requirements, we have the right fan for you. Your advantages at a glance • Optimum design of the working point • Minimum noise emission • High degree of efficiency • Small installation volume thanks to customized designs • High dynamic load capability (3 g to 5 g, railway approval) • Reliable quality • Long service life • Excellent resistance against pollution • For explosion-protection applications • Extremely resistant against vibrations • Special anti-corrosion protection 1/4 mdexx fans for transformer cooling - 2010 The highest level of technology and quality Fans have a huge variety of different tasks to deal with, but this is not a problem for mdexx fans, as they have been designed using the many years of experience we have gathered in the fields of aerodynamics and acoustics, electric motors and new materials. Using our standard range as a basis, we create customized solutions at the highest technical level for a wide variety of industrial applications. A far-reaching automated production flow permits both small and large batch production. Contiguous quality control ensures a high level of technical quality and sophisticated logistics ensures a reliable supply of spare parts for a great many years. So with SIVENT fans you can be sure that you’re getting the very best in terms of cost effectiveness, quality and future orientation. mdexx fans – typical areas of application • Electrical industry • Power transformer cooling • Drive cooling • Railway vehicles • Compressor cooling • Washing-plant technology • Textile industry • Ventilation and clean-room systems • Heating/air-conditioning systems mdexx fans for transformer cooling - 2010 1/5 mdexx fans at a glance Product Axial fans 2CC2, 2CC4 Axial fans 2CT2 Axial fans 2CQ4/5/6 Radial fans 2CF7 Low pressure Low pressure Medium pressure Medium pressure Max. volumetric flow 6 m3/s 20 m3/s 80 m3/s 30 m3/s Max. pressure 600 Pa 200 Pa 2500 Pa 4000 Pa Version • Housing for mounting onto panels or in pipes • Pipe-type housing • Pipe-design enclosure • Galvanized and 3x coated surface • Powder-coated, scratch-resistant surface • Powder-coated, scratch-resistant surface • Single-phase or 3phase motors with 50 Hz or 60 Hz • Pole-changing motors • Motors for non-standard voltages • Single-phase or threephase motor with 50 Hz or 60 Hz or non-standard voltages • Pole-changing motor • Motors for non-standard voltages • Special purpose motors, e.g. explosionprotected motor Number of motor 2/4/6 pole poles • 50 or 60 Hz 3-phase motor (direct drive) • Special-purpose motors, e.g., explosionprotected motor 4/6/8/10/12 pole • Impeller where the fan blades manufacutured out of cast silumin can be individually adjusted at standstill 2/4/6/8 pole • 50 or 60 Hz 3-phase motor (direct drive) • Pole-changing motors • Motors for non-standard voltages • Special-purpose motors, e.g., explosion-protected motor • Impeller with powdercoated, scratch-resistant surface 2/4/6/8 pole 2CQ4: 42 % 2CQ5: 53 % 2CQ6: 67 % Hub ratio Wheel diameter (fan size) 250 to 710 mm 440 to 1,600 mm 250 mm to 2,000 mm 250 to 1,600 mm Accessories • Protective grid • Protective grid • Inlet nozzles • Compensators • Flat-profile flange • Protective grid • Compensator • Feet for horizontal installation • Vibration-damping elements • Flat-profile flange • Compensators 1/6 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 1 Introduction ■ Introduction mdexx fans are used for all power transformer cooling applications, e.g. in transformer substations or power plants, to dissipate the heat losses over external radiators or oil coolers. Our long-standing experience in thedevelopment of blade wheel and housing geometries guarantees minimum noise emission. The fans comply with the market requirements in large-scale transformer engineering and assure fail-safe operation in all climatic zones. ■ Advantages of mdexx Axial Fans mdexx axial fans offer the following advantages: • Long service life • Special corrosion protection • Individual color selection • Operating characteristics matched to the power supply company‘s requirements • Outdoor-suitable housing made of hot-galvanized sheet-steel and featuring an additional coating ■ Corrosion protection Corrosion protection by protective paint systems in accordance with DIN EN ISO 12944-5 with medium protection time Corrosiveness category C3M moderate C4M strong C5M very strong C5H very strong Film thickness in μm 120 160 160 240 Lacquer HV HV ADD ADD ■ Symbols for Fan Data P Number of poles F [Hz] Frequency U [V] Nominal Voltage I [A] Operating current during free blow-out P1 [W] Power consumption during free blow-out N [1/min] Speed VFl [m³/h] Volume flow during free blow-out PST [Pa] Maximum static pressure; VFL is then reduced LWal [dB] A - Sound power level of a fan ■ Regulations of electrical voltages • built according to international IEC standard voltages 400/460 V S +6% / -10% ) Some countries still hold on to the old voltages 380 volts +/- 10% (342 volts up to 418 volts) resp. 415 volts +/- 10 % (374 volts up to 457 volts). In these extreme cases the machine function could be affected. A corresponding transformer or a special motor has to be used. Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 1/7 Fans for transformer cooling 1 Introduction ■ Fans options The order numbers in this cataloge comply with the following specification: - Radiator ( pressure- and suction-side with protection grid) - Sucking over motor - Motor 3 Phase 230 V / 400 V S 50 Hz or 460 V S 60 Hz Beside the listed versions additional accessories and special designs are available. If you are interested in any our products or need further assistance, please e-mail: [email protected] Motor Voltage 230/400 V S 50Hz 500 V S 50Hz 380 V D 50 Hz 500 V D 50Hz 400/690 V 50Hz 380/660 V 50Hz 460 V S 60Hz Motor Design Three phase Single phase EEx e IIC EEx e II Ex nAll T3 to IEC 60079-15 1/8 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Quick Selection 2/2 Configuring aids for fans Fans for transformer cooling 2CT2 Quick Selection 2 ■ Selection and ordering data – all data refer to 400 V S, 50 Hz (-/+ 5% voltage tolerance) in acc. with EN60034-1 max. volume max. volume flow m³/h flow m³/s Volume flow up to 10000 m³/h 2340 0,65 2700 0,75 3700 1,03 4400 1,22 5450 1,51 6500 1,81 9600 2,67 9800 2,72 Volume flow up to 20000 m³/h 12000 3,33 13500 3,75 14600 4,06 14900 4,14 15300 4,25 4,75 17100 18000 5,00 18200 5,00 Volume flow up to 50000 m³/h 21150 5,88 22500 6,25 23000 6,39 25000 6,94 28200 7,83 32500 9,03 40150 11,15 41100 11,42 43600 12,11 49100 13,64 Volume flow up to 100000 m³/h 50500 14,03 52250 14,51 57000 15,83 65500 18,19 73800 20,50 80500 22,36 89200 24,78 99100 27,53 2/2 max. static pressure Pa A-Sound power level No. of poles Frequency free blow-out dB(A) p f Size Type Refererence Page 9 12 22 32 38 70 73 37 48 51 58 63 74 75 81 67 12 10 8 6 8 4 8 12 50 50 50 50 50 50 50 50 440 440 440 440 560 440 630 730 2CT2 445-1EA13-1AA1 2CT2 443-1EA13-1AA1 2CT2 448-1EA13-1AA1 2CT2 446-1EA13-1AA1 2CT2 568-1EA13-1AA1 2CT2 444-1EA13-1AA1 2CT2 638-1EA13-1AA1 2CT2 735-3EA13-1AA1 3/3 3/3 3/3 3/3 4/3 3/3 5/3 6/3 39 38 58 37 57 61 55 80 69 70 74 71 75 76 76 79 12 12 10 12 10 10 10 8 50 50 50 50 50 50 50 50 800 800 800 800 730 800 800 730 2CT2 805-5EA13-1AA1 2CT2 805-4EA13-1AA1 2CT2 803-5EA13--AA1 2CT2 805-3EA13-1AA1 2CT2 733-5EA13-1AA1 2CT2 803-4EA13-1AA1 2CT2 803-3EA13-1AA1 2CT2 738-5EA13-1AA1 7/3 7/3 7/3 7/3 6/3 7/3 7/3 6/3 85 85 154 170 170 66 76 105 82 113 80 81 86 88 87 83 85 89 86 90 8 8 6 6 6 12 12 10 12 10 50 50 50 50 50 50 50 50 50 50 800 800 730 800 800 1000 1000 1000 1000 1000 2CT2 808-5EA13-1AA1 2CT2 808-4EA13-1AA1 2CT2 736-4EA13-1AA1 2CT2 806-4EA13-1AA1 2CT2 806-3EA13-1AA1 2CT2 105-5EA13-1AA1 2CT2 105-4EA13-1AA1 2CT2 103-5EA13-1AA1 2CT2 105-3EA13-1AA1 2CT2 103-4EA13-1AA1 7/3 7/3 6/3 7/3 7/3 8/3 8/3 8/3 8/3 8/3 159 118 165 174 192 198 281 300 94 90 95 94 94 94 99 99 8 10 8 12 12 12 10 10 50 50 50 50 50 50 50 50 1000 1000 1000 1600 1600 1600 1600 1600 2CT2 108-3EA13-1AA1 2CT2 103-3EA13-1AA1 2CT2 108-2EA13-1AA1 2CT1 165-5EB13-1AA0 2CT1 165-4EB13-1AA0 2CT1 165-3EB13-1AA0 2CT1 163-4EB13-1AA0 2CT1 165-5EB13-1AA0 8/3 8/3 8/3 9/3 9/3 9/3 9/3 9/3 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT2 Quick Selection ■ Selection and ordering data – all data refer to 460 V S, 60 Hz (-/+ 5% voltage tolerance) in acc. with EN60034-1 max. volume max. volume flow m³/h flow m³/s Volume flow up to 10000 m³/h 2170 0,60 2700 0,75 3960 1,11 4500 1,25 5830 1,62 6100 1,69 9500 2,64 Volume flow up to 20000 m³/h 11300 3,14 13900 3,86 15600 4,33 17200 4,78 18800 5,22 20100 5,58 5,81 20900 Volume flow up to 50000 m³/h 21100 5,86 26500 7,36 26700 7,42 29000 8,06 32700 9,08 41200 11,44 48300 13,42 48700 13,53 50100 13,92 Volume flow up to 100000 m³/h 51800 14,39 58100 16,14 59300 16,47 63100 17,53 65600 18,22 79300 22,03 89300 24,81 95200 26,44 97400 27,06 max. static pressure Pa A-Sound power level No. of poles Frequency free blow-out dB(A) p f Size Type Refererence Page 8 12 25 34 43 62 68 46 51 59 64 75 74 79 12 10 8 6 8 4 8 60 60 60 60 60 60 60 440 440 440 440 560 440 630 2CT2 445-1EA83-1AA1 2CT2 443-1EA83-1AA1 2CT2 448-1EA83-1AA1 2CT2 446-1EA83-1AA1 2CT2 568-1EA83-1AA1 2CT2 444-1EA83-1AA1 2CT2 638 -1EA83-1AA1 3/4 3/4 3/4 3/4 4/4 3/4 5/4 49 52 51 49 86 84 105 70 72 73 74 79 82 82 12 12 12 12 10 10 8 60 60 60 60 60 60 60 730 800 800 800 730 800 730 2CT2 735-3EA83-1AA1 2CT2 805-5EA83-1AA1 2CT2 805-4EA83-1AA1 2CT2 805-3EA83-1AA1 2CT2 733-5EA83-1AA1 2CT2 803-4EA83-1AA1 2CT2 738-5EA83-1AA1 6/4 7/4 7/4 7/4 6/4 7/4 6/4 76 118 207 229 229 106 201 112 156 79 85 89 91 90 88 97 89 93 10 8 6 6 6 12 8 12 10 60 60 60 60 60 60 60 60 60 800 800 730 800 800 1000 1000 1000 1000 2CT2 803-3EA83-1AA1 2CT2 808-4EA83-1AA1 2CT2 736-4EA83-1AA1 2CT2 806-4EA83-1AA1 2CT2 806-3EA83-1AA1 2CT2 105-3EA83-1AA1 2CT2 108-2EA83-1AA1 2CT2 105-4EA83-1AA1 2CT2 103-3EA83-1AA1 7/4 7/4 6/4 7/4 7/4 8/4 8/4 8/4 8/4 116 210 165 172 218 255 281 367 290 90 97 94 94 98 98 98 103 98 12 8 10 10 8 12 12 10 12 60 60 60 60 60 60 60 60 60 1000 1000 1000 1000 1000 1600 1600 1600 1600 2CT2 105-5EA83-1AA1 2CT2 108-3EA83-1AA1 2CT2 103-4EA83-1AA1 2CT2 103-5EA83-1AA1 2CT2 108-4EA83-1AA1 2CT1 165-3EB83-1AA0 2CT1 165-4EB83-1AA0 2CT1 163-3EB83-1AA0 2CT1 163-5EB83-1AA0 8/4 8/4 8/4 8/4 8/4 9/4 9/4 9/4 9/4 ■ Available upon request • • • • • • • • • • Special voltages Motor protection: temperature monitors (bimetal) or PTC resistor Further ambient conditions, e.g. -40° C Further installation positions, e.g. vertical Air flow direction blowing via motor as of size 560 Individually factory-adjustable operating points as of size 730 mm Higher static pressure up to 290 Pa Pressure- and/or suction-side protection grid as of size 560 Further motor pole configurations from 4- to 24-pole Blade wheels in the following materials: polyamide, aluminum/cast, aluminum/sheet Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 2/3 2 Fans for transformer cooling 2CT2 Quick Selection 2 2/4 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 44 3/2 Technical Data 3/3 Characteristic curves Fans for transformer cooling 2CT2 44 Technical Data ■ Dimension Drawings 2CT2 44 Drehrichtung rotation Förderrichtung air flow direction 400 300 3 ca.128 520 300 440 200 9 230 530 Design: Radiator model, 2 protection grids ■ Technical Data Technical delivery conditions DIN 24166, accuracy class 2 Installation Suitable for outdoor installation Impeller Polypropylene (black, UV-resistant, fail-safe also with intensive (1200 W/m2)) Balance quality Q 6.3 in acc. with ISO 1940 Part 1 Average air flow temperature From -20° C to +50° C Housing Sheet-steel with integrally molded inlet nozzle, hot-galvanized Protection grid Suction- and pressure-side stainless steel protection grids Diameter (blade wheel) 440 mm Volume flow (max.) 2300 - 6400 m³/h Static pressure (max.) 9 - 70 Pa Number of poles 4/6/8/10/12-pole Motor output From 0.05 to 0.43 kW Air flow direction Suction via motor Degree of protection IP55 Isolations class of winding F Varying-voltage winding 50 Hz, 60 Hz: 220-290VD / 380-500VS Electrical connection Inside the motor terminal box (refer to dimension drawing) Installation positions Horizontal and vertical motor shaft (blowing direction) Color Housing hot-galvanized with triple coating RAL7033 (cement gray) Motor Weight 3/2 RAL 9005 (black) Approx. 20 kg mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT2 44 Motors 400 V S, 50 Hz ■ Characteristic curves without protection grid Pressure loss per protection grid PLGrid = 0,2 * (V/3600)2 [m3/h] 80 pfa Static pressure in Pa 3 A 70 60 50 40 B 30 C 20 D 10 E 0 0 1000 2000 3000 4000 5000 6000 7000 Volum e flow in m ³/h Power consumption in kW 0,25 A E 0,00 0 1000 D C 2000 B 3000 4000 5000 6000 7000 Volum en flow in m ³/h ■ Selection and Ordering Data Operating Number Power consumption current during Number of poles during free blow-out free blow-out in p in A Speed Volume Sound presflow maximum A-Sound power sure level in during static preslevel free blow1 m, lateral out free blowsure free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 44, 400 V S, 50 Hz A 4 0,72 430 1140 6500 70 59 75 2CT2 444 -1EA13-1AA1 B 6 0,32 160 770 4400 32 47 63 2CT2 446 -1EA13-1AA1 C 8 0,21 90 645 3700 22 43 58 2CT2 448 -1EA13-1AA1 D 10 0,11 55 475 2700 12 35 51 2CT2 443 -1EA13-1AA1 E 12 0,11 51 410 2340 9 32 48 2CT2 445 -1EA13-1AA1 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 3/3 Fans for transformer cooling 2CT2 44 Motors 460 V S, 60 Hz ■ Characteristic curves without protection grid Pressure loss per protection grid PLGrid = 0,2 * (V/3600)2 [m3/h 3 70 A pfa Static pressure in Pa 60 50 40 B 30 C 20 D 10 E 0 0 1000 2000 3000 4000 5000 6000 7000 Volum e flow in m ³/h Power consumption in kW 0,25 A E 0,00 0 1000 C D 2000 B 3000 4000 5000 6000 7000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating Number Power consumption current during Number of poles during free blow-out free blow-out in p in A Speed Volume Sound presflow maximum A-Sound power sure level in during static preslevel free blow1 m, lateral out free blowsure free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 44, 460 V S, 60 Hz A 4 0,85 545 1070 6101 62 58 74 2CT2 444 -1EA83-1AA1 B 6 0,37 210 790 4514 34 48 64 2CT2 446 -1EA83-1AA1 C 8 0,24 115 690 3958 25 44 59 2CT2 448 -1EA83-1AA1 D 10 0,12 70 475 2700 12 35 51 2CT2 443 -1EA83-1AA1 E 12 0,11 51 380 2169 8 30 46 2CT2 445 -1EA83-1AA1 3/4 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 56 4/2 Technical Data 4/3 Characteristic curves Fans for transformer cooling 2CT2 56 Technical Data ■ Dimension Drawings 2CT2 56 4 Design: Radiator model, 2 protection grids ■ Technical Data Technical delivery conditions DIN 24166, accuracy class 2 Installation Suitable for outdoor installation Impeller Polypropylene (black, UV-resistant, fail-safe also with intensive (1200 W/m2)) Balance quality Q 6.3 in acc. with ISO 1940 Part 1 Average air flow temperature From -20° C to +50° C Housing Sheet-steel with integrally molded inlet nozzle, hot-galvanized Protection grid Suction- and pressure-side stainless steel protection grids Diameter (blade wheel) 560 mm Volume flow (max.) 5500 m³/h Static pressure (max.) 33 Pa Number of poles 8-pole Motor output To 0,3 kW Air flow direction Suction via motor Degree of protection IP55 Isolations class of winding F Varying-voltage winding 50 Hz, 60 Hz: 220-290VD / 380-500VS Electrical connection Inside the motor terminal box (refer to dimension drawing) Installation positions Horizontal and vertical motor shaft (blowing direction) Color Housing hot-galvanized with triple coating RAL7033 (cement gray) Motor Weight 4/2 RAL 9005 (black) Approx. 40 kg mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT2 56 Motors 400 V S, 50 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 4,41 * (V/3600)2 [m3/h] 45 pfa Static pressure in Pa 40 A 35 30 25 4 20 15 10 5 0 0 1000 2000 3000 4000 5000 6000 Volum e flow in m ³/h Power consumption in kW 0,03 A 0,02 0,02 0,01 0,01 0,00 0 1000 2000 3000 4000 5000 6000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating curNumber of Power consumption rent during free Number poles during free blow-out blow-out in p in A Speed Volume flow maximum during static presfree blowsure out Sound presA-Sound power sure level in level free blow1 m, lateral out free blow-out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) 90 645 5450 38 58 74 Fan type Motor size 56, 400 V S, 50 Hz A 8 0,21 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 568 -1EA13-1AA1 mdexx fans for transformer cooling - 2010 4/3 Fans for transformer cooling 2CT2 56 Motors 460 V S, 60 Hz ■ Characteristic curves without protection grid (suction- and pressure side) 50 45 40 35 30 25 20 15 10 5 0 A 0 1000 2000 3000 4000 5000 6000 7000 Volum e flow in m ³/h 0,03 Power consumption in kW 4 pfa Static pressure in Pa Pressure loss per protection grid PLGrid = 4,41 * (V/3600)2 [m3/h] A 0,03 0,02 0,02 0,01 0,01 0,00 0 1000 2000 3000 4000 5000 6000 7000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating curNumber of Power consumption rent during free Number poles during free blow-out blow-out in p in A Speed Volume flow maximum during static presfree blowsure out Sound presA-Sound power sure level in level free blow1 m, lateral out free blow-out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) 115 690 5830 43 59 75 Fan type Motor size 56, 460 V S, 60 Hz A 4/4 8 0,24 mdexx fans for transformer cooling - 2010 2CT2 568 -1EA83-1AA1 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 63 5/2 Technical Data 5/3 Characteristic curves Fans for transformer cooling 2CT2 63 Technical Data ■ Dimension Drawings 2CT2 63 5 Design: Radiator model, 2 protection grids ■ Technical Data Technical delivery conditions DIN 24166, accuracy class 2 Installation Suitable for outdoor installation Impeller Polypropylene (black, UV-resistant, fail-safe also with intensive (1200 W/m2)) Balance quality Q 6.3 in acc. with ISO 1940 Part 1 Average air flow temperature From -20° C to +50° C Housing Sheet-steel with integrally molded inlet nozzle, hot-galvanized Protection grid Suction- and pressure-side stainless steel protection grids Diameter (blade wheel) 630 mm Volume flow (max.) 8100 m³/h Static pressure (max.) 51 Pa Number of poles 8-pole Motor output Up to 0,14 kW Air flow direction Suction via motor Degree of protection IP55 Isolations class of winding F Varying-voltage winding 50 Hz, 60 Hz: 220-290VD / 380-500VS Electrical connection Inside the motor terminal box (refer to dimension drawing) Installation positions Horizontal and vertical motor shaft Color Housing hot-galvanized with triple coating RAL7033 (cement gray) Motor Weight 5/2 RAL 9005 (black) Approx. 60 kg mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT2 63 Motors 400 V S, 60 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 3,92 * (V/3600)2 [m3/h] 80 A pfa Static pressure in Pa 70 60 50 40 30 20 10 0 0 2000 4000 6000 8000 10000 5 12000 Volum e flow in m ³/h Power consumption in kW 0,50 A 0,00 0 2000 4000 6000 8000 10000 12000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating Number Power consumption current during Number of poles during free blow-out free blow-out in p in A Speed Volume flow maximum during static presfree blowsure out Sound presA-Sound power sure level in level free blow1 m, lateral out free blow-out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) 290 835 9600 73 65 81 Fan type Motor size 63, 400 V S, 50 Hz A 8 1,6 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 638 -1EA13-1AA1 mdexx fans for transformer cooling - 2010 5/3 Fans for transformer cooling 2CT2 63 Motors 460 V S, 60 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 3,92 * (V/3600)2 [m3/h] 80 A pfa Static pressure in Pa 70 60 50 40 30 20 10 0 0 5 2000 4000 6000 8000 10000 12000 Volum e flow in m ³/h Power consumption in kW 0,50 A 0,00 0 2000 4000 6000 8000 10000 12000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating Number Power consumption current during Number of poles during free blow-out free blow-out in p in A Speed Volume flow maximum during static presfree blowsure out Sound presA-Sound power sure level in level free blow1 m, lateral out free blow-out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) 440 830 9500 68 69 79 Fan type Motor size 63, 460 V S, 60 Hz A 5/4 8 1 mdexx fans for transformer cooling - 2010 2CT2 638 -1EA83-1AA1 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 73 6/2 Technical Data 6/3 Characteristic curves Fans for transformer cooling 2CT2 73 Technical Data ■ Dimension Drawings 2CT2 73 6 Design: Radiator model, 2 protection grids ■ Technical Data Technical delivery conditions DIN 24166, accuracy class 2 Installation Suitable for outdoor installation Impeller Aluminum cast, seawater-resistant, hot-galvanized hub Balance quality Q 6.3 in acc. with ISO 1940 Part 1 Average air flow temperature From -20° C to +50° C Housing Sheet-steel with integrally molded inlet nozzle, hot-galvanized Protection grid Suction- and pressure-side stainless steel protection grids Diameter (blade wheel) 730 mm Volume flow (max.) 9000 - 25500 m³/h Static pressure (max.) 40 - 160 Pa Number of poles 6/12-pole Motor output From 0,12 to 1,67 kW Air flow direction Suction via motor Degree of protection IP56 Isolations class of winding F Varying-voltage winding 50 Hz, 60 Hz: 220-290VD / 380-500VS Electrical connection Inside the motor terminal box (refer to dimension drawing) Installation positions Horizontal and vertical motor shaft Color Housing hot-galvanized with triple coating RAL7033 (cement gray) Motor Approx. 67 kg Weight 6/2 RAL 9005 (black) mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT2 73 Motors 400 V S, 50 Hz ■ Characteristic curves Pressure loss per protection grid PLGrid = 0,7 * (V/3600)2 [m3/h] 180 pfa Static pressure in Pa 160 A 140 120 100 B 80 C 60 D 40 20 0 0 5000 10000 15000 20000 25000 Volum e flow in m ³/h Power consumption in kW 1,50 A 6 1,00 B 0,50 C D 0,00 0 5000 10000 15000 20000 25000 Volum e flow in m ³/h ■ Selection and Ordering Data Number Number of poles in p Operating curPower consumption rent during during free blow-out free blow-out in A Speed Volume Sound presflow maximum A-Sound power sure level in level free blowduring static pres1 m, lateral free blowsure out free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 73, 400 V S, 50 Hz A 6 5,2 1,4 940 23000 154 70 86 2CT2 736 -4EA13-1AA1 B 8 2,15 0,75 680 18200 80 63 79 2CT2 738 -5EA13-1AA1 C 10 1,9 0,37 570 15300 57 59 75 2CT2 733 -5EA13-1AA1 D 12 1,3 0,13 450 9800 37 51 67 2CT2 735 -3EA13-1AA1 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 6/3 Fans for transformer cooling 2CT2 73 Motors 460 V S, 60 Hz ■ Characteristic curves Pressure loss per protection grid PLGrid = 0,7 * (V/3600)2 [m3/h] pfa Static pressure in Pa 250 A 200 150 B C 100 D 50 0 0 5000 10000 15000 20000 25000 30000 35000 Volum e flow in m ³/h 6 Power consumption in kW 2,50 A 2,00 1,50 B 1,00 C 0,50 D 0,00 0 5000 10000 15000 20000 25000 30000 35000 Volum e flow in m ³/h ■ Selection and Ordering Data Number Number of poles in p Operating curPower consumption rent during during free blow-out free blow-out in A Speed Volume Sound presflow maximum A-Sound power sure level in during static preslevel free blow1 m, lateral free blowsure out free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 73, 460 V S, 60 Hz A 6 5,2 2,2 1090 26670 207 73 89 2CT2 736 -4EA83-1AA1 B 8 2,15 1,1 780 20876 105 66 82 2CT2 738 -5EA83-1AA1 C 10 1,9 0,7 700 18789 86 63 79 2CT2 733 -5EA83-1AA1 D 12 1,3 0,2 520 11324 49 54 70 2CT2 735 -3EA83-1AA1 6/4 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 80 7/2 Technical Data 7/3 Characteristic curves Fans for transformer cooling 2CT2 80 Technical Data ■ Dimension Drawings 2CT2 80 Design: Radiator model, 2 protection grids ■ Technical Data 7 Technical delivery conditions DIN 24166, accuracy class 2 Installation Suitable for outdoor installation Impeller Aluminum cast, seawater-resistant, hot-galvanized hub Balance quality Q 6.3 in acc. with ISO 1940 Part 1 Average air flow temperature From -20° C to +50° C Housing Sheet-steel with integrally molded inlet nozzle, hot-galvanized Protection grid Suction- and pressure-side stainless steel protection grids Diameter (blade wheel) 800 mm Volume flow (max.) 15000 - 24000 m³/h Static pressure (max.) 40 - 100 Pa Number of poles 8/10/12-pole Motor output From 0,29 to 1,11 kW Air flow direction Suction via motor Degree of protection IP55 Isolations class of winding F Varying-voltage winding 50 Hz, 60 Hz: 220-290VD / 380-500VS Electrical connection Inside the motor terminal box (refer to dimension drawing) Installation positions Horizontal and vertical motor shaft Color Housing hot-galvanized with triple coating RAL7033 (cement gray) Motor Weight 7/2 RAL 9005 (black) Approx. 76 kg mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT2 80 Motors 400 V S, 50 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 0,48 * (V/3600)² (m³/h) 180 B 160 A pfa Static pressure in Pa 140 120 100 80 G 60 I 40 20 D H J 0 0 5000 C F E 10000 15000 20000 25000 30000 Volum e flow in m ³/h 2,50 A Power consumption in kW 2,00 B 1,50 C 1,00 D E 0,50 G I H J 0,00 0 5000 10000 15000 7 F 20000 25000 30000 Volum e flow in m ³/h ■ Selection and Ordering Data Number Number of poles in p Operating curPower consumption rent during during free blow-out free blow-out in A Speed Volume Sound presflow maximum A-Sound power sure level in during static preslevel free blow1 m, lateral free blowsure out free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 80, 400 V S, 50 Hz A 6 5,2 2,07 940 28200 170 71 87 2CT2 806 -3EA13-1AA1 B 6 5,2 1,61 940 25000 170 72 88 2CT2 806 -4EA13-1AA1 C 8 2,9 0,97 680 22500 85 65 81 2CT2 808 -4EA13-1AA1 D 8 2,9 0,8 680 21150 85 64 80 2CT2 808 -5EA13-1AA1 E 10 2,9 0,5 545 18000 55 60 76 2CT2 803 -3EA13-1AA1 F 10 2,26 0,46 570 17100 61 60 76 2CT2 803 -4EA13-1AA1 G 10 1,9 0,33 545 14600 58 58 74 2CT2 803 -5EA13-1AA1 H 12 2,2 0,28 450 14900 37 55 71 2CT2 805 -3EA13-1AA1 I 12 2,2 0,23 450 13500 38 54 70 2CT2 805 -4EA13-1AA1 J 12 1,65 0,19 450 12000 39 53 69 2CT2 805 -5EA13-1AA1 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 7/3 Fans for transformer cooling 2CT2 80 Motors 460 V S, 60 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 0,48 * (V/3600)² (m³/h) 250 B A pfa Static pressure in Pa 200 150 100 G I 50 D J 0 0 5000 H 10000 C F E 15000 20000 25000 30000 35000 Volum e flow in m ³/h 3,50 A 7 Power consumption in kW 3,00 B 2,50 2,00 C 1,50 D E 1,00 F G 0,50 I 0,00 0 5000 H J 10000 15000 20000 25000 30000 35000 Volum e flow in m ³/h ■ Selection and Ordering Data Number Number of poles in p Operating curPower consumption rent during during free blow-out free blow-out in A Speed Volume Sound presflow maximum A-Sound power sure level in during static preslevel free blow1 m, lateral free blowsure out free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 80, 460 V S, 60 Hz A 6 5,2 3,2 1090 32700 229 74 90 2CT2 806 -3EA83-1AA1 B 6 5,2 2,5 1090 28989 229 75 91 2CT2 806 -4EA83-1AA1 C 8 2,9 1,6 800 26471 118 69 85 2CT2 808 -4EA83-1AA1 D 8 2,9 1,3 800 24882 118 68 84 2CT2 808 -5EA83-1AA1 E 10 2,9 0,8 640 21138 76 63 79 2CT2 803 -3EA83-1AA1 F 10 2,26 0,7 670 20100 84 64 80 2CT2 803 -4EA83-1AA1 G 10 1,9 0,5 640 17145 80 61 77 2CT2 803 -5EA83-1AA1 H 12 2,2 0,4 520 17218 49 58 74 2CT2 805 -3EA83-1AA1 I 12 2,2 0,4 520 15600 51 57 73 2CT2 805 -4EA83-1AA1 J 12 1,65 0,3 520 13867 52 56 72 2CT2 805 -5EA83-1AA1 7/4 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT2 10 8/2 Technical Data 8/3 Characteristic curves Fans for transformer cooling 2CT2 10 Technical Data ■ Dimension Drawings 2CT2 10 Design: Radiator model, 2 protection grids ■ Technical Data Technical delivery conditions DIN 24166, accuracy class 2 Installation Suitable for outdoor installation Impeller Aluminum sheet, hot-galvanized hub 8 Balance quality Q 6.3 in acc. with ISO 1940 Part 1 Average air flow temperature From -20° C to +50° C Housing Sheet-steel with integrally molded inlet nozzle, hot-galvanized Protection grid Suction- and pressure-side stainless steel protection grids Diameter (blade wheel) 1000 mm Volume flow (max.) 28000 - 51000 m³/h Static pressure (max.) 95 - 175 Pa Number of poles 8/10/12-pole Motor output From 0,65 to 2,75 kW Air flow direction Suction via motor Degree of protection IP55 Isolations class of winding F Varying-voltage winding 50 Hz, 60 Hz: 220-290VD / 380-500VS Electrical connection Inside the motor terminal box (refer to dimension drawing) Installation positions Horizontal and vertical motor shaft Color Housing hot-galvanized with triple coating RAL7033 (cement gray) Motor Weight 8/2 RAL 9005 (black) Approx. 130 kg mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT2 10 Motors 400 V S, 50 Hz ■ Characteristic curves without protection grid (suction- and pressure side) pfa Static pressure in Pa Pressure loss per protection grid PLGrid = 0,36 * (V/3600)2 [m3/h] 180 160 140 120 100 80 60 40 20 0 C B A D F I G E H 0 10000 20000 30000 40000 50000 60000 70000 Volum e flow in m ³/h 3,50 A Power consumption in kW 3,00 B 2,50 D 2,00 E F 1,50 G 1,00 H I 0,50 0,00 0 10000 20000 30000 40000 50000 60000 70000 8 Volum e flow in m ³/h ■ Selection and Ordering Data Operating curNumber Power consumption rent during free Number of poles during free blow-out blow-out in p in A Speed Volume flow maximum during static presfree blowsure out Sound presA-Sound power sure level in level free blow1 m, lateral out free blow-out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 10, 400 V S, 50 Hz A 8 7,6 2,9 700 57000 165 79 95 2CT2 108 -2EA13-1AA1 B 8 7,6 2,52 700 50500 159 78 94 2CT2 108 -3EA13-1AA1 C 8 5,7 2,07 700 42000 152 78 94 2CT2 108 -4EA13-1AA1 D 10 6,5 2,12 575 52250 118 74 90 2CT2 103 -3EA13-1AA1 E 10 6,5 1,84 575 49100 113 74 90 2CT2 103 -4EA13-1AA1 F 10 4,7 1,37 570 41100 105 73 89 2CT2 103 -5EA13-1AA1 G 12 5,7 1,24 480 43600 82 70 86 2CT2 105 -3EA13-1AA1 H 12 4,2 1 470 40150 76 69 85 2CT2 105 -4EA13-1AA1 I 12 3,45 0,67 450 32500 66 67 83 2CT2 105 -5EA13-1AA1 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 8/3 Fans for transformer cooling 2CT2 10 Motors 460 V S, 60 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 0,36 * (V/3600)2 [m3/h] pfa Static pressure in Pa 250 200 C 150 F B A D G 100 I E 50 H 0 0 10000 20000 30000 40000 50000 60000 70000 Volum e flow in m ³/h 5,00 A 4,50 B Power consumption in kW 4,00 D 3,50 E 3,00 F 2,50 G 2,00 1,50 H I 1,00 0,50 0,00 8 0 10000 20000 30000 40000 50000 60000 70000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating curNumber Power consumption Number rent during free of poles during free blow-out blow-out in p in A Speed Volume flow maximum during static presfree blowsure out Sound presA-Sound power sure level in level free blow1 m, lateral out free blow-out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 10, 460 V S, 60 Hz A 8 7,6 4,4 805 65550 218 82 98 2CT2 108 -4EA83-1AA1 B 8 7,6 3,8 805 58075 210 81 97 2CT2 108 -3EA83-1AA1 C 8 5,7 3,1 805 48300 201 81 97 2CT2 108 -2EA83-1AA1 D 10 6,5 3,7 695 63154 172 78 94 2CT2 103 -5EA83-1AA1 E 10 6,5 3,2 695 59347 165 78 94 2CT2 103 -4EA83-1AA1 F 10 4,7 2,5 695 50113 156 77 93 2CT2 103 -3EA83-1AA1 G 12 5,7 2,1 570 51775 116 74 90 2CT2 105 -5EA83-1AA1 H 12 4,2 1,8 570 48693 112 73 89 2CT2 105 -4EA83-1AA1 I 12 3,45 1,4 570 41167 106 72 88 2CT2 105 -3EA83-1AA1 8/4 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. 2CT1 16 9/2 Technical Data 9/3 Characteristic curves Fans for transformer cooling 2CT1 16 Technical Data ■ Dimension Drawings 2CT1 16 ■ Technical Data Technical delivery conditions DIN 24166, accuracy class 2 Installation Suitable for outdoor installation Impeller Aluminum sheet, hot-galvanized hub 9 Balance quality Q 6.3 in acc. with ISO 1940 Part 1 Average air flow temperature From -20° C to +50° C Housing Sheet-steel with integrally molded inlet nozzle, hot-galvanized Protection grid Suction- and pressure-side stainless steel protection grids Diameter (blade wheel) 1000 mm Volume flow (max.) 65500 - 99100 m³/h Static pressure (max.) 174 - 300 Pa Number of poles 10/12-pole Motor output From 3,2 to 8,7 kW Air flow direction Suction via motor Degree of protection IP55 Isolations class of winding F Varying-voltage winding 50 Hz, 60 Hz: 220-290VD / 380-500VS Electrical connection Inside the motor terminal box (refer to dimension drawing) Installation positions Horizontal and vertical motor shaft Color Housing hot-galvanized with triple coating RAL7033 (cement gray) Motor Weight 9/2 RAL 9005 (black) Approx. xxx kg mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Fans for transformer cooling 2CT1 16 Motors 400 V S, 50 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 0,1 * (V/3600)2 [m3/h] 350 A pfa Static pressure in Pa 300 B C 250 D E 200 F 150 100 50 0 0 20000 40000 60000 80000 100000 120000 Power consumption in kW Volum e flow in m ³/h 10,00 9,00 8,00 7,00 6,00 5,00 4,00 3,00 2,00 1,00 0,00 A B C D E F 0 20000 40000 60000 80000 100000 120000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating Number Power consumption Number current during of poles during free blow-out free blow-out in p in A Speed Volume Sound presflow maximum A-Sound power sure level in during static preslevel free blow1 m, lateral free blowsure out free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type 9 Motor size 16, 400 V S, 50 Hz A 10 24 8,7 575 99100 300 75 99 2CT1 163 -3EB13-1AA0 B 10 24 7,5 585 89200 281 75 99 2CT1 163 -4EB13-1AA0 C 10 16 6 575 79300 255 75 99 2CT1 163 -5EB13-1AA0 D 12 18 4,6 475 80500 198 70 94 2CT1 165 -3EB13-1AA0 E 12 18 4 475 73800 192 70 94 2CT1 165 -4EB13-1AA0 F 12 18 3,2 475 65500 174 70 94 2CT1 165 -5EB13-1AA0 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 9/3 Fans for transformer cooling 2CT1 16 Motors 460 V S, 60 Hz ■ Characteristic curves without protection grid (suction- and pressure side) Pressure loss per protection grid PLGrid = 0,1 * (V/3600)2 [m3/h] pfa Static Pressure in Pa 500 450 400 350 300 250 200 150 100 50 0 A B C D E F 0 20000 40000 60000 80000 100000 120000 140000 120000 140000 Power consumption in kW Volum e flow in m ³/h 17,00 16,00 15,00 14,00 13,00 12,00 11,00 10,00 9,00 8,00 7,00 6,00 5,00 4,00 3,00 2,00 1,00 0,00 A B C D E F 0 20000 40000 60000 80000 100000 Volum e flow in m ³/h ■ Selection and Ordering Data Operating Number Power consumption Number current during of poles during free blow-out free blow-out 9 in p in A Speed Volume Sound presflow maximum A-Sound power sure level in during static preslevel free blow1 m, lateral free blowsure out free blow-out out in kW in 1/min in m³/h in Pa in dB(A) in dB(A) Fan type Motor size 16, 460 V S, 60 Hz A 10 24 15,7 700 120643 445 79 103 2CT1 163 -5EB83-1AA0 B 10 24 12,8 700 106735 402 79 103 2CT1 163 -4EB83-1AA0 C 10 16 10,4 690 95160 367 79 103 2CT1 163 -3EB83-1AA0 D 12 18 8,2 575 97447 290 74 98 2CT1 165 -5EB83-1AA0 E 12 18 7,1 575 89337 281 74 98 2CT1 165 -4EB83-1AA0 F 12 18 5,7 575 79289 255 74 98 2CT1 165 -3EB83-1AA0 9/4 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Annex 10/2 Conditions of Sale and Delivery Annex Conditions of Sale and Delivery Export regulations ■ Conditions of Sale and Delivery ■ Export regulations You can purchase the products outlined in this catalogue from mdexx GmbH in accordance to the following specifications. The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Except in cases where deviating and individually stipulated terms or deviations of the specification listed below are agreed on, the "General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry" individually issued by the society ZVEI are applicable in connection to the amendment provision "Ergänzungsklausel Erweiterter Eigentumsvorbehalt" (Overall reservation of title) issued by ZVEI respectively for the time when the order is placed. The specification can be requested from us or be looked up in the internet (www.mdexx.de). Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL Products marked other than “N“ require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. The belonging price lists and the prices indicated in the catalog and the internet are applicable in € (Euro) ex delivery facility (EXW-Incoterms 2000) excluding shipping costs and packaging. The tax on purchases and sales is not included in prices. It will be calculated individually according to the legal requirements following the valid rate. With the acceptance of our order confirmation or the ordered goods or services, our Sales- and Purchase Conditions are binding for the buyer. Deviating business terms of the buyer will not be applied. They neither become part of the contract terms by receipt of the orders nor by other implied actions. Pallets, containers and other reusable packaging remain property of mdexx GmbH. They have to be returned by the buyer free of costs to the delivery facility immediately following delivery of goods. Non-returnable packaging is charged at cost price and not taken back. General Notes Price alterations, minimum order values and minimum order quantities are reserved and are informed about following order confirmation, if applicable. In this case the delivery of goods is carried out subject to receiving a written confirmation of these deviating conditions and the subsequently resulting contract. Number of the German Export List. Goods labeled with an “AL not equal to N“ are subject to a European or German export authorization when being exported out of the EU. ECCN Export Control Classification Number. Products marked other than “N“ are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “ECCN not equal to N“ are subject to a US re-export authorization. Even without a label or with an “AL: N“ or “ECCN: N“, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. Technical Delivery Conditions For delivery of fans the "General conditions for the operation of mdexx-fans" are applicable. This conditions can be requested from us or be looked up in the internet (www.mdexx.de). They are supplemented by a users manual if necessary. 10 10/2 mdexx fans for transformer cooling - 2010 Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx Magnetronic Devices your reliable partner for: Step-Up/Step-Down-, control-, isolating-, safety-, line- and powertransformers as well as power supplies Line and output reactors, radio interference suppression filter for mains connection of non-linear loads and output filter to adapt the cable length and as motor protection, filter reactors for reactive power compensation systems Axial fans and radial flow fans as standard products and optimal designed solutions for selected branches Please sent your requirements t your mdexx contact person. Adress see appendix or www.mdexx.com Inquiries: [email protected] Alterations and mistakes are reserved. Dimensions are approximate indications. Similar illustrations. mdexx fans for transformer cooling - 2010 10/3
Similar documents
Handicrafts and Needlework
2593B Lampshades, constructed 2640B Lampshades, pre-constructed decorated 2599B
More information