Industrial Ethernet Cables CAT5, CAT6 and CAT7
Transcription
Industrial Ethernet Cables CAT5, CAT6 and CAT7
SPECIAL CABLES · TEMPERATURE MEASUREMENT · HARNESSING INDUSTRIAL ETHERNET CABLES CONTENT OVERVIEW Who we are ......................................................................................................... 3 INDUSTRIAL ETHERNET CABLES Industrial Ethernet Cables Profinet n PN 662 PVC Profinet cable type B for flexible applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 n PN 663 PVC Profinet cable type B for flexible applications with UL recognition n S PN 668 PUR Profinet cable type C, continuously flexible, suitable for cable tracks ......................... ...................... 4 4 4 n S PN 669 PUR Profinet cable type C, continuously flexible, suitable for cable tracks with UL recognition n PN 654 PVC Profinet cable type A for fixed installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 n PN 655 PVC Profinet cable type A for fixed installation with UL recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 n PN 660 halogen-free Profinet cable type B for flexible applications n PN 661 halogen-free Profinet cable type B for flexible applications with UL recognition n S PN 667 PUR Profinet cable type C, continuously flexible with UL recognition, CSA approval . ....................................... ................ 5 5 .......... 6 .................................... 7 Industrial Ethernet Cables CAT 5 n PN 678 PVC Ethernet cable type A for fixed installation, twisted pairs n PN 679 PUR Ethernet cable type B for flexible applications, twisted pairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 n S PN 681 PUR Ethernet cable type C, continuously flexible, suitable for cable tracks, twisted pair n DR PN 689 P Highflex PUR reeling Profinet cable / CAT 5 cable n DR CB 689 P Highflex PUR reeling CAN-Bus cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 n S PN 668 Hybrid PUR Hybrid cable, continuously flexible, suitable for cable tracks with UL recognition n RT PN 668 PUR Profinet cable suitable for robots ....... 7 .......................................................... 8 ......... 9 .............................................................. 9 Industrial Gigabit Ethernet Cables CAT 6 / CAT 6A / CAT 7A 10 n CAT 6 S CAT 6 Gigabit Ethernet cable, suitable for cable tracks with UL recognition, CSA approval n CAT 6A S CAT 6A Gigabit Ethernet cable, suitable for cable tracks with UL recognition, CSA approval . 10 n CAT 6 RT CAT 6 Gigabit Ethernet cable, suitable for robots with UL recognition, CSA approval n CAT 6A RT CAT 6A Gigabit Ethernet cable, suitable for robots with UL recognition, CSA approval n CAT 6A HT CAT 6A Gigabit Ethernet cable, high temperature resistant with UL recognition . . . . . . . . . . . . . . . . 11 n CAT 7A S CAT 7A Gigabit Ethernet cable, suitable for cable tracks with UL recognition, CSA approval . 12 n CAT 7A RT CAT 7A Gigabit Ethernet cable, suitable for robots with UL recognition, CSA approval n CAT 6A DR n CAT 7A DR .. ......... ....... 10 10 ....... 12 reeling CAT 6A Gigabit Ethernet cable ............................................................. 13 reeling CAT 7A Gigabit Ethernet cable ............................................................. 13 Industrial Ethernet Cables CAT 5e, CAT 6A and CAT 7A especially for use in rail vehicles 14 n CAT 5e R halogen-free CAT 5e Industrial Ethernet cable n CAT 6A R halogen-free CAT 6A Gigabit Ethernet cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 n CAT 7A R halogen-free CAT 7A Gigabit Ethernet cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 ..................................................... Industrial Ethernet Cables CAT 5e, CAT 6A and CAT 7A especially for maritime use 15 n CAT 5e BL halogen-free CAT 5e Industrial Ethernet cable with UL recognition and ABS Type Approval n CAT 6A BL halogen-free CAT 6A Gigabit Ethernet cable with UL recognition and ABS Type Approval . . . . 15 n CAT 7A BL halogen-free CAT 7A Gigabit Ethernet cable with UL recognition and ABS Type Approval . . . . 15 .. Application of Industrial ETHERNET Cables Industrial Ethernet is a young and quickly developing network technology. Ethernet with the worldwide accepted TCP/IP (Transmission Control Protocol/Internet Protocol) will be the future connection to the well established field bus or sensor / actuator level. Generally, the following transmission rates are divided into: SHARED ETHERNET = FAST ETHERNET = GIGABIT ETHERNET = 10 Mbit/s 100 Mbit/s (CAT 5 requirements) 1000 Mbit/s (1 Gbit/s) S BRÖCKSKES developed a variety of cable solutions due to the strong innovative force of automation industry. Depending on the application, we are able to offer today CAT 5, CAT 6 and CAT 7 cable solutions for flexible and continuous flexible use, for chemical and thermal stress as well as special cable constructions for reeling purpose and robot operation. 2 www.sab-cable.com WHO WE ARE AN OVERVIEW M ore than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff members. Our strength is not only the production of standard products but also the development and manufacturing of special products acc. to customers’ specifications. Every year we manufacture more than 1500 special products on our customers’ request. Every single product is a challenge for our technical team. We at B Bröckskes see ourselves as manufacturer and service provider - in the sense of real partnership and customer oriented work. The quality of our products is known in more than 40 countries worldwide. Our customers have tested our products intensively and confirm that they have a longer service life than others. In all product ranges we are certified acc. to ISO 9001:2008. Besides we established an environmental management system for our company acc. to ISO 14001:2004, an occupational health and safety management acc. to NLF/ILO-OSH 2001 and OHSAS 18001:2007 as well as an energy management system acc. to DIN EN ISO 50001:2011. And our future slogan is: WE GO FORWARD! FOUNDED: 1947 by Peter Bröckskes sen. an independent, medium-sized company. CEO: Peter Bröckskes and Sabine Bröckskes-Wetten PLANT/LOCATION: In Viersen (Lower Rhine) 110.000 m2 company site. Own manufacturing from copper conductor to outer sheath. EMPLOYEES/WORKERS: Approx. 420 at the plant in Viersen, 500 worldwide YEARLY SALES: Approx. 95 Mio. € worldwide PRODUCTS: Special Cables Temperature Measurement Cable Harnessing CERTIFICATES AND APPROVALS: Quality management system acc. to ISO 9001:2008 for every manufacturing field k VDE proofed burnchamber and laboratory within the company. Environmental management system acc. to ISO 14001:2004 Occupational health and safety management acc. to NLF/ILO-OSH 2001 and OHSAS 18001:2007 Energy management system acc. to DIN EN ISO 50001:2011 www.sab-cable.com 3 INDUSTRIAL ETHERNET CABLES PN 662 PN 663 S PN 668 S PN 669 Profinet cable type B for flexible applications Profinet cable type B for flexible applications with UL recognition Profinet cable type C, continuously flexible Profinet cable type C, continuously flexible with UL recognition 3 EN · S PN 668 Profinet CAT 5 Typ C 2x2x22AWG C Marking for S PN 668: S BRÖCKSKES · D-VIERSEN · S PN 668 Profinet CAT 5 Typ C 2x2x22AWG C PN 662 Profinet type B flexible Construction: Dimension: Conductor: S PN 668 Profinet type C continuously flexible S PN 669 Profinet type C continuously flexible 2 x 2 x 22 AWG tinned copper strands, tinned copper strands, fine wires extra fine wires acc. to VDE 0812 tinned copper strands, fine wires acc. to VDE 0812 Core insulation: PN 663 Profinet type B flexible PE, L/MD acc. to DIN VDE 0819 part 103 PE, L/MD acc. to DIN VDE 0819 part 103 PE Colour code: PE blue, yellow, white, orange Stranding: in layers Wrapping: PETP foil Inner sheath: thermoplastic material Wrapping: alu foil Screen: tinned copper braiding Wrapping: Outer sheath: --- non-woven tape --- non-woven tape PVC PUR PVC PUR Sheath colour: green (similar RAL 6018) Technical data: PN 662 Profinet type B flexible S PN 668 Profinet type C continuously flexible PN 663 Profinet type B flexible S PN 669 Profinet type C continuously flexible 0662-2202 0668-2202 0663-2202 0669-2202 Item number: Peak operating voltage VDE: max. 350 V Voltage UL: --- Testing voltage: - 30°C / + 70°C - 5°C / + 70°C - 40°C / + 70°C - 30°C / + 70°C 5xd 10 x d 5xd 10 x d 15 x d Characteristic impedance: Oil resistance: --- acc. to DIN VDE 0472 part 815 + IEC 60754-1 acc. to internal standard TMPU acc. to DIN VDE 0282 part 10 + HD 22.10 Absence of harmful substances: type 06622202 06682202 06632202 06692202 PN 662 S PN 668 PN 663 S PN 669 UL: up to + 80°C - 30°C / + 70 °C - 5°C / + 70 °C UL: up to + 80°C - 30°C / + 70 °C - 20°C / + 70 °C 5xd 10 x d 5xd 10 x d 15 x d 100Ω ± 5Ω, accomplishes the electrical and transmission requirements with high frequency acc. to EN 50288-2-2 (CAT 5 acc. to EN 50173-1) Halogen-free: item no. 300 V core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application: continuously flexible: acc. to DIN VDE 0472 part 815 + IEC 60754-1 --- acc. to internal standard acc. to RoHS directive of the European Union no. of cores cross section 4 4 4 4 AWG 22 22 22 22 max. core-ø mm 1,55 1,55 1,55 1,55 outer-ø ± 5% mm 6,0 6,4 6,5 6,9 copper figure kg/km 33,9 36,7 36,2 36,7 cable weight ≈kg/km 58 58 66 69 ohmic resistance at 20°C acc. to VDE 0812 max.Ω/km 58,0 58,0 58,0 58,0 Other dimensions and colours are possible on request. 4 tinned copper strands, extra fine wires www.sab-cable.com INDUSTRIAL ETHERNET CABLES PN 654 PN 655 Profinet cable type A for fixed installation Profinet cable type A for fixed installation with UL recognition PN 660 PN 661 3 Profinet cable type B for flexible applications Profinet cable type B for flexible applications with UL recognition D-VIERSEN · PN 660 Profinet CAT 5 Typ B 2x2x22AW Marking for PN 660: S BRÖCKSKES · D-VIERSEN · PN 660 Profinet CAT 5 Typ B 2x2x22AWG C Construction: PN 654 Profinet type A fixed laying PN 660 Profinet type B flexible bare copper wire bare copper strands, fine wires acc. to VDE 0812 Dimension: PN 655 Profinet type A fixed laying PN 661 Profinet type B flexible 2 x 2 x 22 AWG Conductor: Core insulation: bare copper wire bare copper strands, fine wires acc. to VDE 0812 PE, L/MD acc. to DIN VDE 0819 part 103 Colour code: blue, yellow, white, orange Stranding: in layers Wrapping: PETP foil Inner sheat: Wrapping: --- thermoplastic material --- thermoplastic material --- alu foil --- alu foil Screen: tinned copper braiding Wrapping: Outer sheath: --- non-woven tape --- non-woven tape PVC S PVC S Sheath colour: green (similar RAL 6018) Technical data: PN 654 Profinet type A fixed laying PN 660 Profinet type B flexible 0654-2202 0660-2202 Item number: Peak operating voltage VDE: 300 V - 30°C / + 70°C - 5°C / + 70°C - 30°C / + 70°C - 20°C / + 70°C 5xd 5xd 12 x d Characteristic impedance: UL: up to + 80°C - 30°C / + 70 °C - 5°C / + 70 °C UL: up to + 75°C - 40°C / + 70 °C - 30°C / + 70 °C 5xd 5xd 12 x d 100Ω ± 5Ω, accomplishes the electrical and transmission requirements with high frequency acc. to EN 50288-2-2 (CAT 5 acc. to EN 50173-1) Halogen-free: --- Oil resistance: acc. to DIN VDE 0472 part 815 + IEC 60754-1 --- acc. to DIN VDE 0472 part 815 + IEC 60754-1 --- acc. to internal standard --- acc. to internal standard Absence of harmful substances: PN 654 PN 660 PN 655 PN 661 0661-2202 core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application: 06542202 06602202 06552202 06612202 0655-2202 --- Testing voltage: type PN 661 Profinet type B flexible max. 350 V Voltage UL: item no. PN 655 Profinet type A fixed laying acc. to RoHS directive of the European Union no. of cores cross section 4 4 4 4 AWG 22 22 22 22 max. core-ø mm 1,55 1,55 1,55 1,55 outer-ø ± 5% mm 5,3 6,6 5,9 6,6 copper figure kg/km 28,0 36,2 30,4 36,2 cable weight ≈kg/km 43 67 51 70 ohmic resistance at 20°C acc. to VDE 0812 max.Ω/km 58,0 58,0 58,0 58,0 Other dimensions and colours are possible on request. www.sab-cable.com 5 INDUSTRIAL ETHERNET CABLES S PN 667 Profinet cable type C, continuously flexible with UL recognition, CSA approval with nnect“ „Fast Couction constr 3 98 80°C 300V CSA AWM I/II A/B 80°C 300V FT2 C Marking for S PN 667: S BRÖCKSKES · D-VIERSEN · S PN 667 Industrial Ethernet FC Cat 5 Typ C 2x2x22AWG x AWM Style 21198 80°C 300V CSA AWM I/II A/B 80°C 300V FT2 C Construction: Conductor: tinned copper strands, 7 wires Core insulation: special polymer Colour code: blue, yellow, white, orange Stranding: in layers Wrapping: PETP foil Inner sheath: thermoplastic material Wrapping: alu foil Technical data: Peak operating voltage VDE: max. 350 V Voltage UL/CSA: 300 V Testing voltage: core/core 1500 V core/screen 1200 V Min. bending radius fixed laying: flexible application: continuously flexible: 5xd 10 x d 15 x d Screen: tinned copper braiding Wrapping: non-woven tape Outer sheath: PUR Temperature range fixed laying: flexible application: UL/CSA: up to +80 °C -30/+70 °C -20/+70 °C Sheath colour: green (similar RAL 6018) Halogen-free: acc. to DIN VDE 0472 part 815 + IEC 60754-1 Characteristic impedance: 100Ω ± 5Ω, accomplishes the electrical and transmission requirements with high frequency acc. to EN 50288-2-2 (CAT 5 acc. to EN 50173-1) Oil resistance: TMPU acc. to DIN VDE 0282 part 10 + HD 22.10 Absence of harmful substances: acc. to RoHS directive of the European Union item no. 06672202 type no. of cores cross section 4 AWG 22 S PN 667 max. core-ø mm 1,55 outer-ø mm 6,5 ± 0,2 copper figure kg/km 33,8 cable weight ohmic resistance at 20°C acc. to VDE 0812 max.Ω/km 58,8 ≈kg/km 60 Other dimensions and colours are possible on request. For extremely during multiple-shift operation - conductor construction 19 wires: item no. 06679001 type S PN 667 no. of cores cross section 4 AWG 22 max. core-ø mm 1,55 outer-ø mm 6,5 ± 0,2 copper figure kg/km 33,8 cable weight ≈kg/km 58 ohmic resistance at 20°C acc. to VDE 0812 max.Ω/km 58,8 Other dimensions and colours are possible on request. short assembling time by „Fast Connect” construction (7 wires) 6 www.sab-cable.com INDUSTRIAL ETHERNET CABLES PN 678 PN 679 Ethernet cable type A for fixed installation Ethernet cable type B for flexible applications S PN 681 3 Ethernet cable type C, continuously flexible D-VIERSEN · PN 679 CAT 5 Typ B 4x2x26AWG C Marking for PN 679: S BRÖCKSKES · D-VIERSEN · PN 679 CAT 5 Typ B 4x2x26AWG C PN 678 Ethernet cable type A fixed laying PN 679 Ethernet cable type B flexible Dimension: 4 x 2 x 26 AWG Conductor: tinned copper wire tinned copper strands, fine wires acc. to VDE 0812 Construction: Core insulation: S PN 681 Ethernet cable type C continuously flexible tinned copper strands, extra fine wires S PE, L/MD acc. to DIN VDE 0819 part 103 Colour code: white cores with numbers 1 - 4 (+ blue, orange, green, brown) Stranding: twisted pairs Wrapping: alu foil PETP foil + alu foil Screen: non-woven tapes + alu foil tinned copper braiding Wrapping: --- Outer sheath: non-woven tape PVC PUR Sheath colour: green (similar RAL 6018) Technical data: PN 678 Ethernet cable type A fixed laying PN 679 Ethernet cable type B flexible S PN 681 Ethernet cable type C continuously flexible 0678-2604 0679-2604 0681-2604 Item number: Peak operating voltage VDE: max. 350 V Testing voltage: core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application: continuously flexible: Characteristic impedance: - 30°C / + 70°C - 5°C / + 70°C - 40°C / + 70°C - 40°C / + 70°C - 40°C / + 90°C - 30°C / + 90°C 5xd 5xd 10 x d 5xd 10 x d 12 x d 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency acc. to EN 50288-2-2 (CAT 5 acc. to EN 50173-1) Halogen-free: --- acc. to DIN VDE 0472 part 815 + IEC 60754-1 Oil resistance: acc. to internal standard TMPU acc. to DIN VDE 0282 part 10 + HD 22.10 Absence of harmful substances: item no. 06782604 06792604 06812604 type PN 678 PN 679 S PN 681 acc. to RoHS directive of the European Union no. of pairs cross section 4 4 4 AWG 26 26 26 max. core-ø mm 1,10 1,10 1,10 outer-ø ± 5% mm 6,2 7,3 7,2 copper figure kg/km 33,0 35,0 35,5 cable weight ≈kg/km 49 58 58 ohmic resistance at 20°C acc. to VDE 0812 max.Ω/km 150 148 145 Other dimensions and colours are possible on request. www.sab-cable.com 7 INDUSTRIAL ETHERNET CABLES DR PN 689 P Highflex reeling Profinet cable / CAT 5 cable DR CB 689 P Highflex reeling CAN-Bus cable 3 D-VIERSEN · DR PN 689 P Highflex 2x2x22AWG C Marking for DR PN 689 P Highflex: S BRÖCKSKES · D-VIERSEN · DR PN 689 P Highflex 2x2x22AWG C Construction: DR PN 689 P Highflex reeling Profinet cable DR PN 689 P Highflex reeling CAT 5 cable DR CB 689 P Highflex reeling CAN-Bus cable 2 x 2 x 22 AWG 4 x 2 x 26 AWG 2 x 2 x 0,50 mm2 Dimension: Conductor: tinned copper strands, fine wires Core insulation: S Colour code: blue, yellow, white, orange Stranding: PE blue, orange, green, brown + 4 white cores with consecutive numbers in layers acc. to DIN 47100 in pairs Wrapping: PETP foli non-woven tape Inner sheath: S --- alu foil --- Wrapping: Screen: tinned copper braiding Wrapping: non-woven tape Outer sheath: --- PUR / supporting braid / PUR Sheath colour: green (similar RAL 6018) Technical data: black (similar RAL 9005) DR PN 689 P Highflex reeling Profinet cable DR PN 689 P Highflex reeling CAT 5 cable DR CB 689 P Highflex reeling CAN-Bus cable 0689-2202 0689-9001 0689-9005 Item number: Peak operating voltage VDE: max. 350 V Testing voltage: core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: - 40°C / + 90°C - 30°C / + 90°C Min. bending radius for laying and installation (fixed laying): for repeated winding action (flexible): guided on deflection pulleys (flexible): Characteristic impedance: - 40°C / + 70°C - 40°C / + 70°C 5xd 10 x d 12 x d for laying and installation (fixed laying): 5xd for repeated winding action (flexible): 7,5 x d guided on deflection pulleys (flexible): 10 x d 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-2-2 (CAT 5 acc. to EN 50173-1) Halogen-free: 120Ω (95 - 140Ω) at 1 MHz acc. to DIN VDE 0472 part 815 + IEC 60754-1 Oil resistance: TMPU acc. to EN 50363-10-2 Absence of harmful substances: item no. type 06892202 06899001 06899005 DR PN 689 P Highflex DR PN 689 P Highflex DR CB 689 P Highflex acc. to RoHS directive of the European Union dimension outer-ø approx. mm copper figure kg/km cable weight ≈kg/km ohmic resistance at 20°C acc. to VDE 0812 max.Ω/km tensile strength max. N characteristic impedance 2 x 2 x 22 AWG 4 x 2 x 26 AWG 2 x 2 x 0,50 mm2 7,8 8,7 13,0 36,2 34,3 48,8 78 85 175 58,8 139 39,0 200 200 200 100Ω 100Ω 120Ω Other dimensions and colours are possible on request. 8 www.sab-cable.com INDUSTRIAL ETHERNET CABLES S PN 668 Hybrid Hybrid cable with UL recognition RT PN 668 Profinet cable suitable for robots 3 VIERSEN · RT PN 668 Profinet 2x2x22AWG · Robot C Marking for RT PN 668: S BRÖCKSKES · D-VIERSEN · RT PN 668 Profinet 2x2x22AWG · Robot Cable · C S PN 668 Hybrid Hybrid cable type C continuously flexible RT PN 668 Profinet cable suitable for robots Dimension: 2 x 2 x 22 AWG + 4 x 1,5 mm2 2 x 2 x 22 AWG Conductor: 22 AWG: tinned copper strands, extra fine wires 1,5 mm2: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 6 22 AWG: S . 1,5 mm2: TPE 22 AWG: blue, yellow, white, orange. 1,5 mm2: black cores with consecutive numbers acc. to EN 50334 22 AWG: in layers together in layers Construction: Insulation: Colour code: Stranding: tinned copper strands, extra fine wires PE blue, yellow, white, orange in layers Wrapping: PETP foli netting tape, alu foil Inner sheath: S --- alu foil --- Wrapping: Screen: tinned copper braiding Wrapping: non-woven tape Sheath material: PUR Sheath colour: green (similar RAL 6018) Technical data: S PN 668 Hybrid Hybrid cable type C continuously flexible Item number: RT PN 668 Profinet cable suitable for robots 0668-9010 0668-9001 Peak operating voltage: max. 350 V Voltage: UL: 300 V Testing voltage: --core/core 1500 V, core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius UL: up to + 80°C - 40°C / + 90°C - 30°C / + 90°C fixed laying: 5xd flexible application: 10 x d continuously flexible: 12 x d Characteristic impedance: - 40°C / + 70°C - 30°C / + 70°C fixed laying: 5xd flexible application: 10 x d torsion angle: ± 180°/m 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-2-2 (CAT 5 acc. to EN 50173-1) Halogen-free: acc. to DIN VDE 0472 part 815 + IEC 60754-1 Oil resistance: PUR, TMPU acc. to DIN VDE 0282 part 10 + HD 22.10 Absence of harmful substances: item no. type 06689010 06689001 S PN 668 Hybrid RT PN 668 suitable for robots acc. to RoHS directive of the European Union no. of cores cross section 8 4 AWG 22 + 16 22 approx. core-ø mm 1,50 / 2,15 1,50 outer-ø ± 5% mm 10,0 7,0 copper figure kg/km 94,1 36,3 cable weight ≈kg/km 158 62 ohmic resistance at 20°C acc. to VDE 0812 max.Ω/km 58,0 / 13,3 58,0 Other dimensions and colours are possible on request. www.sab-cable.com 9 INDUSTRIAL ETHERNET CABLES CAT 6 + CAT 6A suitable for cable / suitable for robots 3 49 80°C 300V CSA AWM I/II A/B 80°C 300V FT2 C Marking for CATLine CAT 6 S: S BRÖCKSKES · D-VIERSEN · Cat.6 S 4x2x26AWG 1677-4630 u AWM Style 20549 80°C 300V CSA AWM I/II A/B 80°C 300V FT2 C Construction: CAT 6 S CAT 6A S suitable for cable tracks CAT 6 RT suitable for cable tracks Dimension: 4 x 2 x 26 AWG Conductor: bare copper strands, fine wires Insulation: white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Stranding: cores twisted to pairs, pairs together Wrapping: non-woven tape Screen: alu foil Screen: tinned copper braiding Wrapping: non-woven tape Sheath material: PUR Sheath colour: green (similar RAL 6018) Technical data: CAT 6 S Item number: CAT 6A S CAT 6 RT suitable for cable tracks suitable for robots suitable for robots 1677-4630 1677-4631 1687-4630 1687-4631 max. 90 V Voltage UL/CSA: 300 V Testing voltage: core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application: continuously flexible: UL/CSA: up to + 80°C - 40°C / + 70 °C - 40°C / + 70 °C Torsion: Characteristic impedance (100 MHz): 5xd 10 x d 15 x d 5xd 10 x d --- up to ± 180°/m 100Ω ± 5Ω, 100Ω ± 5Ω, 100Ω ± 5Ω, 100Ω ± 5Ω, accomplishes accomplishes accomplishes accomplishes the electrical and the electrical and the electrical and the electrical and transmission requirements transmission requirements transmission requirements transmission requirements with high frequency with high frequency with high frequency with high frequency with reference to with reference to with reference to with reference to EN 50288-5-2 / CAT 6 EN 50288-10-2 / CAT 6A EN 50288-5-2 / CAT 6 EN 50288-10-2 / CAT 6A Halogen-free: acc. to DIN VDE 0472 part 815 + IEC 60754-1 Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2 UL Horizontal Flame Test FT2 Oil resistance: TMPU acc. to EN 50363-10-2 Flexibility: very good Absence of harmful substances: type no. of cores CATLine CAT 6 S CATLine CAT 6A S CATLine CAT 6 RT CATLine CAT 6A RT 8 8 8 8 acc. to RoHS directive of the European Union cross section AWG 26 26 26 26 max. core-ø mm 1,05 1,05 1,05 1,05 outer-ø ± 5% mm 7,1 7,1 7,1 7,1 copper figure kg/km 32,0 32,0 32,0 32,0 cable weight ≈kg/km 57 57 57 57 Other dimensions and colours are possible on request. 10 CAT 6A RT suitable for cable tracks Peak operating voltage: 16774630 16774631 16874630 16874631 suitable for robots special polymer Colour code: item no. CAT 6A RT suitable for robots www.sab-cable.com +90°C on request! INDUSTRIAL ETHERNET CABLES CAT 6A HT Gigabit Ethernet cable, high temperature resistant 3 AWG 1631-4631 u AWM Style 21618 150°C 600 S BRÖCKSKES · D-VIERSEN · Marking for CATLine CAT 6A HT: Cat.6A HT 4x2x26AWG 1631-4631 u AWM Style 21618 150°C 600V C Technical data: Construction: Conductor: bare copper strands, fine wires Peak operating voltage: max. 90 V Core insulation: FEP Voltage UL: 600 V Colour code: white/blue, white/orange, white/green, white/brown Testing voltage: core/core 1500 V core/screen 1200 V Stranding: twisted to pairs Wrapping: non-woven tape Screen: alu foil Min. bending radius fixed laying: flexible application: 5xd 10 x d Screen: tinned copper braiding UL: up to +150 °C -90/+180 °C -55/+180 °C Outer sheath: FEP Temperature range fixed laying: flexible application: Sheath colour: green (similar RAL 6018) Characteristic impedance: 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency acc. to EN 50288-10-2 (CAT 6A) Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1 + EN 60332-1-2, UL VW1 Oil resistance: very good Chemical resistance: very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds Outstanding features: ® high temperature resistant ® low temperature resistant ® flame retardant and self-extinguishing ® oil- and chemical resistant ® UL recognized item no. type no. of cores 16314631 CATLine CAT 6A HT 4x2 cross section AWG 26 Absence of harmful substances: max. core-ø mm max. 1,05 outer-ø ± 5% mm 5,7 copper figure kg/km 30,0 acc. to RoHS directive of the European Union cable weight ≈kg/km 52 Other dimensions and colours are possible on request. www.sab-cable.com 11 INDUSTRIAL ETHERNET CABLES CAT 7A suitable for cable / suitable for robots 3 49 80°C 300V CSA AWM I/II A/B 80°C 300V FT2 C Marking for CATLine CAT 7A S: S BRÖCKSKES · D-VIERSEN · Cat.7A S 4x2x26AWG 1777-4631 x AWM Style 20549 80°C 300V CSA AWM I/II A/B 80°C 300V FT2 C Construction: CAT 7A S CAT 7A RT suitable for cable tracks suitable for robots Dimension: 4 x 2 x 26 AWG Conductor: bare copper strands, fine wires Insulation: special polymer Colour code: white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Stranding: cores twisted to pairs, pairs screened with foil, pairs together Screen: aluminized non-woven tape Screen: tinned copper braiding Wrapping: non-woven tape Sheath material: PUR Sheath colour: green (similar RAL 6018) Technical data: CAT 7A S CAT 7A RT suitable for cable tracks Item number: 1777-4631 1787-4631 Peak operating voltage: max. 90 V Voltage UL/CSA: 300 V Testing voltage: core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application: continuously flexible: UL/CSA: up to + 80°C - 40°C / + 70 °C - 40°C / + 70 °C Torsion: Characteristic impedance (100 MHz): 5xd 10 x d 15 x d 5xd 10 x d --- up to ± 180°/m 100Ω ± 5Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-9-2 / CAT 7A Halogen-free: acc. to DIN VDE 0472 part 815 + IEC 60754-1 Fire performance: flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2 UL Horizontal Flame Test FT2 Oil resistance: TMPU acc. to EN 50363-10-2 Flexibility: very good Absence of harmful substances: item no. 17774631 17874631 suitable for robots type no. of cores CATLine CAT 7A S CATLine CAT 7A RT 8 8 acc. to RoHS directive of the European Union cross section AWG 26 26 max. core-ø mm 1,60 1,60 outer-ø ± 5% mm 8,8 8,8 copper figure kg/km 38,5 38,5 cable weight ≈kg/km 80 80 Other dimensions and colours are possible on request. 12 www.sab-cable.com +90°C on request! INDUSTRIAL ETHERNET CABLES CAT 6A DR + CAT 7A DR reeling Gigabit Ethernet cable 3 VIERSEN · Cat.6A DR 4x2x26AWG 1639-465 Marking for CATLine CAT 6A DR: Cat.6A DR 4x2x26AWG 1639-4651 C S BRÖCKSKES · D-VIERSEN · Construction: CAT 6A DR CAT 7A DR reeling Ethernet cable reeling Ethernet cable Dimension: 4 x 2 x 26 AWG Conductor: bare copper strands, fine wires Insulation: special polymer Colour code: white-blue/blue, white-orange/orange, white-green/green, white-brown/brown Stranding: cores twisted to pairs, pairs screened with foil, pairs together cores twisted to pairs, pairs together Wrapping: Screen: non-woven tape --- alu foil aluminized non-woven tape Screen: tinned copper braiding Wrapping: non-woven tape Sheath material: PUR / supporting braid / PUR Sheath colour: black (RAL 9005) Technical data: CAT 6A DR CAT 7A DR reeling Ethernet cable Item number: reeling Ethernet cable 1639-4651 1739-4651 Peak operating voltage: max. 90 V Testing voltage: core/core 600 V - core/screen 600 V Temperature range VDE fixed laying: flexible application: Min. bending radius - 50°C / + 90 °C - 40°C / + 90 °C for laying and installation (fixed laying): 5 x d for repeated winding action (flexible): 10 x d guided on deflection pulleys (flexible): 12 x d Characteristic impedance (100 MHz): 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A Halogen-free: acc. to DIN VDE 0472 part 815 + IEC 60754-1 Weather resistance: very good Oil resistance: TMPU acc. to EN 50363-10-2 Absence of harmful substances: item no. 16394651 17394651 type CATLine CAT 6A DR CATLine CAT 7A DR 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-9-2 / CAT 7A no. of cores 8 8 acc. to RoHS directive of the European Union cross section AWG 26 26 max. core-ø mm 1,05 1,60 outer-ø ± 5% mm 8,7 10,5 copper figure kg/km 32,0 38,5 cable weight ≈kg/km 81 117 tensile strength max. N 200 200 Other dimensions and colours are possible on request. www.sab-cable.com 13 INDUSTRIAL ETHERNET CABLES CAT 5e R CAT 6A R CAT 7A R SEN · 5-2 E N 4554 halogen-free Industrial Ethernet cables for Railway Technology 3 Cat.5e R 4x2x24AWG 1567-4421 C Marking for CATLine CAT 5e R 15674421: S BRÖCKSKES · D-VIERSEN · Cat.5e R 4x2x24AWG 1567-4421 C Construction: CAT 5e R CAT 6A R flexible Dimension: CAT 7A R flexible 2 x 2 x 24 AWG / 2 x 2 x 22 AWG / 4 x 2 x 24 AWG flexible 4 x 2 x 26 AWG Conductor: bare copper strands, fine wires Insulation: PE Colour code: blue, yellow, white, orange Stranding: white-blue/blue, white-orange/orange, white-green/green, white-brown/brown star quad twisted to pairs Wrapping: twisted to pairs with alu foil foil Screen: alu foil and tinned copper braiding Sheath material: special A Sheath colour: green (similar RAL 6018) Technical data: Item number: CAT 5e R CAT 6A R CAT 7A R flexible flexible flexible 1567-9002 / 1567-9004 / 1567-4421 1667-4621 1767-4621 Peak operating voltage: max. 90 V Testing voltage: core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application: Characteristic impedance: - 40°C / + 70°C - 30°C / + 70°C 5xd 12 x d 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-2-2 / CAT 5 Halogen-free: Fire performance: 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A 100Ω ± 10Ω, accomplishes the electrical and transmission requirements with high frequency with reference to EN 50288-9-2 / CAT 7A acc. to DIN EN 50306-1 + DIN EN 50264-1. Development of HCl is ≤ 0,5% acc. to DIN EN 50267-2-1. pH-value is ≥ 4,3 acc. to DIN EN 50267-2-2. Conductivity is ≤ 10,0 μS/mm acc. to DIN EN 50267-2-2. Fluoric content ≤ 0,1% acc. to DIN EN 60684-2 No flame propagation acc. to DIN EN 60332-3-25 + DIN EN 50305 section 9.1.1 + 9.1.2. Flame retardant and self-extinguishing acc. to DIN EN 60332-1-2 Smoke density: acc. to DIN EN 61034 Toxicity: acc. to DIN EN 50305 Flexibility: good Absence of harmful substances: Outstanding features: ® halogen-free ® no flame propagation ® flame retardant and self-extinguishing ® fulfils fire protection requirements R15 (EL1A) acc. to DIN EN 45545-2 for hazard levels HL1-3 acc. to RoHS directive of the European Union item no. type 15679002 15679004 15674421 16674621 17674621 CATLine CAT 5e R CATLine CAT 5e R CATLine CAT 5e R CATLine CAT 6A R CATLine CAT 7A R no. of cores 4 4 8 8 8 cross section AWG 24 22 24 26 26 max. core-ø mm max. 1,30 max. 1,60 max. 1,30 max. 1,05 max. 1,60 outer-ø ± 5% mm 5,2 ± 5% 5,9 ± 5% 8,0 ± 10% 6,8 ± 10% 7,8 ± 10% copper figure kg/km 22,7 29,1 41,2 36,3 38,5 Other dimensions and colours are possible on request. Especially for use in rail vehicles 14 www.sab-cable.com cable weight ≈kg/km 41 52 70 58 82 INDUSTRIAL ETHERNET CABLES CAT 5e BL CAT 6A BL CAT 7A BL halogen-free Ethernet cables for maritime use 3 4x2x24AWG 1747-4421 u AWM Style 21080 75°C 30 Marking for CATLine CAT 7A BL 17474421: Cat.7A BL 4x2x24AWG 1747-4421 u AWM Style 21080 75°C 300V C S BRÖCKSKES · D-VIERSEN · Construction: Dimension: CAT 5e BL CAT 6A BL 2 x 2 x 24 AWG 4 x 2 x 26 AWG 2 x 2 x 22 AWG Conductor: CAT 7A BL 4 x 2 x 24 AWG / 4 x 2 x 26 AWG bare copper strands, fine wires Insulation: special polymer Colour code: blue, yellow, white, orange Stranding: white-blue/blue, white-orange/orange, white-green/green, white-brown/brown star quad cores twisted to pairs, pairs together Wrapping: cores twisted to pairs, pairs screened with foil, pairs together alu foil Screen: tinned copper braiding Sheath material: special S Sheath colour: black Technical data: CAT 5e BL 1547-9001 1547-9002 Item number: CAT 6A BL 1547-4621 1647-4621 + 1647-4421 Peak operating voltage: 1747-4621 + 1747-4421 max. 90 V Voltage UL: 300 V Testing voltage: core/core 1500 V - core/screen 1200 V Temperature range VDE fixed laying: flexible application: Min. bending radius fixed laying: flexible application (only 7 wires): Characteristic impedance (100 MHz): CAT 7A BL UL: up to + 75°C - 40°C / + 70 °C - 30°C / + 70 °C 5xd 10 x d 100Ω ± 10Ω, accomplishes 100Ω ± 10Ω, accomplishes 100Ω ± 10Ω, accomplishes the electrical and the electrical and the electrical and transmission requirements with high transmission requirements with high transmission requirements with high frequency frequency frequency with reference to with reference to with reference to EN 50288-2-2 / CAT 5 EN 50288-10-2 / CAT 6A EN 50288-9-2 / CAT 7A Halogen-free: Fire performance: Corrosiveness of conflagration gases: acc. to IEC 60754-1 + IEC 60754-2 flame retardant and self-extinguishing acc. to IEC 60332-1-2 + EN 60332-1-2, no flame propagation acc. to IEC 60332-3-22 cat. A, UL Horizontal Flame Test FT2, UL AWM Style 21080 IEC 60754-2 - no development of corrosive conflagration gases Smoke density acc. to IEC 61034 Flexibility: good Absence of harmful substances: Outstanding features: ® ABS Type Approval ‰ TR IEC 60092-370 ‰ halogen-free ‰ asbestos-free ‰ flame retardant and self-extinguishing ‰ no flame propagation ‰ UL recognized acc. to RoHS directive of the European Union item no. type 15479001 15479002 15474621 16474621 16474421 17474621 17474421 CATLine CAT 5e BL CATLine CAT 5e BL CATLine CAT 5e BL CATLine CAT 6A BL CATLine CAT 6A BL CATLine CAT 7A BL CATLine CAT 7A BL no. of cores 4 4 8 8 8 8 8 cross core-ø outer-ø section ± 5% AWG mm mm 24/7 approx. 1,25 5,7 22/7 max. 1,60 6,4 26/7 max. 1,05 7,3 26/7 max. 1,05 7,3 24/7 approx. 1,33 8,3 26/7 max. 1,60 8,9 24/7 approx. 1,60 10,5 copper figure kg/km 22,7 29,7 31,9 31,9 41,1 38,5 65,0 cable weight ≈kg/km 48 61 64 64 81 85 116 Other dimensions and colours are possible on request. Especially for use in shipbuilding industry www.sab-cable.com 15 S B R Ö C KS K E S G M B H & C O . KG G R E F R AT H E R ST R . 20 4 - 212 B 4174 9 V I E R S E N · G E R M A N Y T E L .: +4 9/2162/8 9 8-0 FA X : +4 9/2162/8 9 8-101 W W W.S A B -WO R L DW I D E .C O M 10/2016 I N F O @S A B -B R O E C KS K E S .D E