INTERRUPTORES Y SENSORES DE PRESION Y TEMPERATURA
Transcription
INTERRUPTORES Y SENSORES DE PRESION Y TEMPERATURA
Desde1963 INTERRUPTORES Y Proveedor SENSORES DEIntegral PRESION Y de Soluciones para TEMPERATURA la Industria INTERRUPTORES Y SENSORES DE PRESION Y TEMPERATURA Los interruptores ASCO Tripoint, utilizan la tecnología de diafragma/pistón para un sensado preciso de presión y temperatura, garantizado un excelente tiempo de vida. Los materiales de fabricación son diversos y dependen de fluido a manejar. Los SENSORES ASCO son maquinados en una sola pieza (cuerpo y diafragma) para eliminar los problemas ocasionados por el desgaste de partes internas, garantizando así el tiempo más largo del mercado. Sensores ASCO Interruptores ASCO TRIPOINT ® ASCO Pressure and Temperature Switch SELECTION GUIDE and INDEX Switches Type Set Point Reset Point Enclosure Ranges Pages Sealed 6.5 - 162 (psig) 2-3 Open Frame, General Purpose, Watertight 4 - 200 (psig) 4-7 PRESSURE J-SERIES Miniature Pressure Switches with Non-Adjustable Set Points Pressure Non-Adjustable Fixed H-SERIES Miniature Pressure Switches with Adjustable Set Points Pressure Adjustable Fixed, Adjustable P-SERIES Switches for Vacuum - 6000 psig with Open Frame, Type 1 or Type 4 Enclosures Vacuum, Compound, Pressure Adjustable Fixed, Adjustable Open Frame, General Purpose, Watertight Vacuum 6000 (psig) 8 - 13 S-SERIES Switches for Vacuum - 8000 psig, or Differential with Type 1, Type 4 or Type 7, 9 Enclosures Pressure, Vacuum, Differential, Combustion In. of W.C. Adjustable General Purpose, Fixed, Watertight, Adjustable, Manual Reset Explosion-Proof Vacuum 8000 (psig) 14 - 23 TEMPERATURE P-SERIES Switches for -60 through 510°F with Open Frame, Type 1 or Type 4 Enclosures Temperature Adjustable Fixed, Adjustable Open Frame, General Purpose, -60 - 510°F Watertight 24 - 29 S-SERIES Switches for -60 through 640° F with Type 1, Type 4 or Type 7, 9 Enclosures Temperature Adjustable General Purpose, Fixed, -60 - 640°F Watertight, Adjustable, Manual Reset Explosion-Proof 30 - 33 Options, Definitions and Compatibility Table.........Pages 34 through Inside Back Cover 1 J-SERIES Miniature Pressure Switches Low-Cost Switches with Non-Adjustable Set Points Features: • Tamperproof, factory-set, non-adjustable set points. • Fixed deadband. • Environmentally sealed against dust, water, oil and salt spray, e.g., for off-highway equipment. • Vented construction for stable set points throughout operating range. • Vibration and shock resistant to 10 G’s. • Precision electrical snap-action switch. General Description: J-Series miniature pressure switches have factory-set non-adjustable set points and fixed deadband, with diaphragm/piston sensor. J-Series switches are CSA approved and UL listed under “Industrial Control Equipment”. J-Series switches are sealed with specially compounded epoxy that maintains its sealing integrity from -40 to 250°F. Proof pressure: 250 psig. (Consult factory for higher pressures). Process connection: Standard: 1/8” NPT Ext, 1/8” NPT Int, 1/4” NPT Ext. Optional: 1/4” NPT Int (eighth digit “3”). Standard Electrical Ratings Dimensions (inches) J-Series Pressure With Terminal Screw Connections With Lead Wires 1 INCH DIA. 1 INCH DIA. 18 5 Amp Res., 125 VAC 5 Amp Res., 250 VAC 3 Amp Res., 28 VDC &% 3.5 Standard Temperature Ratings Ambient: -4°F (-20°C) to 140°F (60°C) Fluid: -4°F (-20°C) to 180°F (82°C) 4 Wetted Materials (Process Connection & Diaphragm) Standard: Brass and Buna “N” Optional Process Connections: • 316 SS (sixth digit “4”) • Carbon steel (sixth digit “6”) Optional Diaphragms: • FKM (seventh digit “2”) • Neoprene (seventh digit “3”) • Ethylene propylene (seventh digit “6”) • Fluorosilicone (seventh digit “7”) 2 1/8 NPT INTERNAL, 1/8 NPT EXTERNAL OR 1/4 EXTERNAL Switch Options Gold contacts for low power circuits: Add Suffix “P” Tight deadband, 25-50% reduction: Add Suffix “T” 11 Amp Res., 125 VAC contacts: Add Suffix “Y” 4 123 Select J-Series pressure switch below How to Select and Order 1/8” NPT 1/4” NPT 1/8” NPT Mfg. Set External Process External Process Internal Process Decreasing Increasing Point Connection Connection Connection 3 Pressure Pressure Tolerance (psig) (psig) Catalog No. Catalog No. Catalog No. (psig) Set Point ASCO J-Series switches are a single switch and transducer assembly. 1 2 Normally open, screw terminals, Brass and Buna “N” How to Select 6.5 10.5 18.5 30 40 56 71 93 138 1. Select type of switch (normally open, normally closed or SPDT and screw terminal or wire leads). 2. Select desired set point for either decreasing pressure or increasing pressure. 3. Select desired process connection. How to Order 8.5 12.5 22 35 45 65 85 108 162 1.2 1.5 2 3 4 6 7 8 12 JB67A218A JB57A218A JB47A218A JB37A218A JB27A218A JB17A218A JC37A218A JC27A218A JC17A218A JB67A214A JB57A214A JB47A214A JB37A214A JB27A214A JB17A214A JC37A214A JC27A214A JC17A214A JB67A215A JB57A215A JB47A215A JB37A215A JB27A215A JB17A215A JC37A215A JC27A215A JC17A215A Normally open, 18” lead wires, Brass and Buna “N” Simply order the selected J-Series pressure switch by catalog number, e.g., JB67A218A describes a normally open, screw terminal pressure switch with set point decreasing of 6.5 psig and set point increasing of 8.5 psig, 1/8” NPT external brass process connection and Buna “N” diaphragm. 6.5 10.5 18.5 30 40 56 71 93 138 Options Add appropriate suffix or change appropriate digit in catalog number for desired option, e.g., JB67A2 2 8A P describes a normally open, screw terminal pressure switch with optional FKM diaphragm (seventh digit “2”) and gold contact snap switch (suffix “P”). 8.5 12.5 22 35 45 65 85 108 162 1.2 1.5 2 3 4 6 7 8 12 JB68A218A JB58A218A JB48A218A JB38A218A JB28A218A JB18A218A JC38A218A JC28A218A JC18A218A JB68A214A JB58A214A JB48A214A JB38A214A JB28A214A JB18A214A JC38A214A JC28A214A JC18A214A JB68A215A JB58A215A JB48A215A JB38A215A JB28A215A JB18A215A JC38A215A JC28A215A JC18A215A Normally closed, screw terminals, Brass and Buna “N” 6.5 10.5 18.5 30 40 56 71 93 138 8.5 12.5 22 35 45 65 85 108 162 1.2 1.5 2 3 4 6 7 8 12 JB67A218B JB57A218B JB47A218B JB37A218B JB27A218B JB17A218B JC37A218B JC27A218B JC17A218B JB67A214B JB57A214B JB47A214B JB37A214B JB27A214B JB17A214B JC37A214B JC27A214B JC17A214B JB67A215B JB57A215B JB47A215B JB37A215B JB27A215B JB17A215B JC37A215B JC27A215B JC17A215B Normally closed, 18” lead wires, Brass and Buna “N” 6.5 10.5 18.5 30 40 56 71 93 138 8.5 12.5 22 35 45 65 85 108 162 1.2 1.5 2 3 4 6 7 8 12 JB68A218B JB58A218B JB48A218B JB38A218B JB28A218B JB18A218B JC38A218B JC28A218B JC18A218B JB68A214B JB58A214B JB48A214B JB38A214B JB28A214B JB18A214B JC38A214B JC28A214B JC18A214B JB68A215B JB58A215B JB48A215B JB38A215B JB28A215B JB18A215B JC38A215B JC28A215B JC18A215B SPDT (Form “C” contact), 18” lead wires, Brass and Buna “N” 6.5 10.5 18.5 30 40 56 71 93 138 1 2 3 8.5 12.5 22 35 45 65 85 108 162 1.2 1.5 2 3 4 6 7 8 12 JB68A218C JB58A218C JB48A218C JB38A218C JB28A218C JB18A218C JC38A218C JC28A218C JC18A218C JB68A214C JB58A214C JB48A214C JB38A214C JB28A214C JB18A214C JC38A214C JC28A214C JC18A214C JB68A215C JB58A215C JB48A215C JB38A215C JB28A215C JB18A215C JC38A215C JC28A215C JC18A215C Values shown are nominal. Deadband value is difference between the increasing and decreasing set points. May be used for panel or bracket mounting. 3 H-SERIES Miniature Pressure Switches Low-Cost Switches with Adjustable Set Points Features: • Field adjustable set points. • Fixed deadband. • Choice of open frame type, general purpose or watetight enclosure. • Small size. • Mounts in any position. • Rugged and vibration resistant, e.g., for compressors. • Visual adjustment scales in psig and bars. General Description: H-Series miniature pressure switches have field adjustable set points and fixed deadband, with diaphragm/piston sensor. They are available in open frame construction, Type 1 general purpose or Type 4 watertight enclosures. The resilient diaphragm/piston construction helps provide long life and maintains set point repeatability despite environmental temperature variations. The full size electical switch is a precision UL listed, snap-action type. H-Series switches are CSA approved and are UL listed under “Industrial Control Equipment”. Proof pressure: 250 psig. (Consult factory for higher pressures). Process connection: Standard: 1/8” NPT Ext, 1/8” NPT Int, 1/4” NPT Ext. Optional: 1/4” NPT Int (eighth digit “3”). Standard Electrical Ratings 15 Amp Res., 125 VAC 10 Amp Res., 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC SPDT NO C NC ^ % 1 1 Open frame construction, UL recognized component. Wetted Materials (Process Connection & Diaphragm) Standard: Brass and Buna “N” Optional Process Connections: • 316 SS (sixth digit “4”) • Carbon steel (sixth digit “6”) Optional Diaphragms: • FKM (seventh digit “2”) • Neoprene (seventh digit “3”) • Ethylene propylene (seventh digit “6”) • Fluorosilicone (seventh digit “7”) Standard Temperature Ratings Ambient: -4°F (-20°C) to 140°F (60°C) Fluid: -4°F (-20°C) to 180°F (82°C) 4 Switch Options See page 34 for optional snap switches. 4 123 Select H-Series pressure switch below How to Select and Order SPDT (Form “C” Contact), Brass and Buna “N” ASCO H-Series switches are a single switch and transducer assembly. Adjustable Operating Range (psig) How to Select 1. Select type of switch (open frame, general purpose or watertight).. 2. Select the adjustable operating range based on the desired actuation pressure. 3. Select desired process connection. Fixed 1/8” NPT 1/4” NPT 1/8” NPT Deadband External Process External Process Internal Process At Connection Connection Connection 2 Mid-Range (psig) 1 Catalog No. Catalog No. Catalog No. Open frame construction 4 8 20 35 40 80 How to Order Simply order the selected H-Series pressure switch by catalog number, e.g., HB46A218 describes an open frame pressure switch with adjustable operating range of 4 to 12 psig, 1/8” NPT external brass process connection and Buna “N” diaphragm. - HB46A218 HB36A218 HB26A218 HB16A218 HC26A218 HC16A218 1.6 1.8 2.4 3.5 7.0 10.0 12 25 50 80 120 200 HB46A214 HB36A214 HB26A214 HB16A214 HC26A214 HC16A214 HB46A215 HB36A215 HB26A215 HB16A215 HC26A215 HC16A215 HB40A214 HB30A214 HB20A214 HB10A214 HC20A214 HC10A214 HB40A215 HB30A215 HB20A215 HB10A215 HC20A215 HC10A215 HB41A214 HB31A214 HB21A214 HB11A214 HC21A214 HC11A214 HB41A215 HB31A215 HB21A215 HB11A215 HC21A215 HC11A215 Type 1 - General purpose enclosure 4 8 20 35 40 80 Options Add appropriate suffix or change appropriate digit in catalog number for desired option, e.g., HB46A2 2 8 P describes an open frame pressure switch with optional FKM diaphragm (seventh digit “2”) and gold contact snap switch (suffix “P”). - HB40A218 HB30A218 HB20A218 HB10A218 HC20A218 HC10A218 1.6 1.8 2.4 3.5 7.0 10.0 12 25 50 80 120 200 Type 4 - Watertight enclosure 4 8 20 35 40 80 1 - HB41A218 HB31A218 HB21A218 HB11A218 HC21A218 HC11A218 1.6 1.8 2.4 3.5 7.0 10.0 12 25 50 80 120 200 Values shown are nominal. 2 May be used for panel or bracket mounting. Dimensions (inches) H-Series Pressure General Purpose Enclosure 1.7 2.8 2.2 Open Frame Watertight Enclosure 2.5 2.1 1.0 .8 5.0 5.2 3.5 1/8 NPT INTERNAL .9 1/8 NPT INTERNAL 4.0 1/2NPT 7/8 KNOCKOUT BOTH SIDES 1/8 NPT EXTERNAL OR 1/4 EXTERNAL 1.0 1/8 NPT INTERNAL 5 H-SERIES Miniature Pressure Switches Suffix S: Low-Cost Switches with Adjustable Set Points and Adjustable Deadband Features: • Field adjustable set points. • Limited adjustable deadband. • Choice of open frame type, general purpose or watetight enclosure. • Small size. • Mounts in any position. • Rugged and vibration resistant, e.g., for compressors. • Visual adjustment scales in psig and bars. Standard Ratings and Wetted Materials (See page 4) Dimensions (See page 5) How to Select and Order Select H-Series Suffix S switch below ASCO H-Series Suffix S switches are a single switch and transducer assembly. How to Select Adjustable Operating Range (psig) 1. Select type of switch enclosure (open frame, general purpose or watertight). 2. Select the adjustable operating range based on the desired actuation pressure and desired deadband (reactuation) pressure. 3. Select desired process connection. Open frame construction 4 8 20 35 40 80 How to Order Simply order the selected H-Series Suffix S pressure switch by catalog number, e.g., HB46A218S describes an open frame H-Series Suffix S pressure switch with adjustable operating range of 4 to 12 psig and adjustable deadband at mid-range of 1.5 to 3.5 psig, 1/8” NPT external brass process connection and Buna “N” diaphragm. - 12 25 50 80 120 200 1.5 2 3 6 8 15 - 3.5 4 5 8 13 20 HB46A218S HB36A218S HB26A218S HB16A218S HC26A218S HC16A218S HB46A214S HB36A214S HB26A214S HB16A214S HC26A214S HC16A214S HB46A215S HB36A215S HB26A215S HB16A215S HC26A215S HC16A215S HB40A214S HB30A214S HB20A214S HB10A214S HC20A214S HC10A214S HB40A215S HB30A215S HB20A215S HB10A215S HC20A215S HC10A215S HB41A214S HB31A214S HB21A214S HB11A214S HC21A214S HC11A214S HB41A215S HB31A215S HB21A215S HB11A215S HC21A215S HC11A215S Type 1 - General purpose enclosure 4 8 20 35 40 80 Options (See page 4) Change appropriate digit in catalog number for desired option, e.g., HB46A2 2 8S describes an open frame pressure switch with adjustable operating range and deadband with optional FKM diaphragm (seventh digit “2”). - 12 25 50 80 120 200 1.5 2 3 6 8 15 - 3.5 4 5 8 13 20 HB40A218S HB30A218S HB20A218S HB10A218S HC20A218S HC10A218S Type 4 - Watertight enclosure 4 8 20 35 40 80 1 6 SPDT (Form “C” Contact), Brass and Buna “N” Adjustable Deadband 1/8” NPT 1/4” NPT 1/8” NPT At External Process External Process Internal Process Mid-Range Connection Connection Connection 2 (psig) 1 Catalog No. Catalog No. Catalog No. From/To - 12 25 50 80 120 200 1.5 2 3 6 8 15 - 3.5 4 5 8 13 20 Values shown are nominal. HB41A218S HB31A218S HB21A218S HB11A218S HC21A218S HC11A218S 2 May be used for panel or bracket mounting. 4 123 Suffix L: Lowest-Cost Switches with Adjustable Set Points (Open Frame Construction) Features: • Low cost for OEM applications. • Miniature size. • Wide selection of adjustable ranges. • Fixed deadband. • Resilient diaphragm/piston sensor for long life. • Precision single-pole, double-throw snap switch with quick-connect 1/4” spade terminals. Standard Ratings and Wetted Materials (See page 4) Dimensions (inches) How to Select and Order 2.2 1.2 ASCO H-Series Suffix L switches are a single switch and transducer assembly. How to Select 1. Select the adjustable operating range based on the desired actuation pressure. 2. Select desired process connection. 3.4 How to Order Simply order the selected H-Series Suffix L pressure switch by catalog number, e.g., HB46A218L describes an open frame pressure switch with adjustable operating range of 4 to 12 psig, 1/8” NPT external brass process connection and Buna “N” diaphragm. Options (See page 4) Select H-Series Suffix L switch below Change appropriate digit in catalog number for desired option, e.g., HB46A2 2 8L describes an open frame pressure switch with adjustable operating range and optional FKM diaphragm (seventh digit “2”). Note: Optional snap switches not available on suffix “L” units. SPDT (Form “C” Contact), Brass and Buna “N” Adjustable Operating Range (psig) 4 8 20 35 40 80 1 - 12 25 50 80 120 200 Fixed 1/8” NPT 1/4” NPT 1/8” NPT Deadband External Process External Process Internal Process At Connection Connection Connection 2 Mid-Range Catalog No. Catalog No. Catalog No. (psig) 1 3.0 3.6 5.5 7.0 14.0 21.0 Values shown are nominal. HB46A218L HB36A218L HB26A218L HB16A218L HC26A218L HC16A218L 2 HB46A214L HB36A214L HB26A214L HB16A214L HC26A214L HC16A214L HB46A215L HB36A215L HB26A215L HB16A215L HC26A215L HC16A215L May be used for panel or bracket mounting. 7 P-SERIES Pressure Switches Switches for Vacuum through 6000 psig with Adjustable Set Points and Fixed or Adjustable Deadband Features: • Set point repeatability, +1% of operating range. • All wiring terminals, adjustments and visual scales are accessible from the front of the switch. • Choice of open frame type, general purpose or watertight enclosure. • Choice of fixed, limited-adjustable or full-range adjustable deadband. • Choice of single or two-stage units. • Compact size. • Mounts in any position. • Rugged and vibration resistant; e.g., for compressors. • Visual adjustment scales in psig and bars. • Wide selection of transducer wetted materials suitable for air, water, oil or corrosive fluids. • Mix and match switch and transducer components for increased stock flexibility or to change pressure ranges in field. General Description: ASCO P-Series pressure switches consist of an open frame or enclosure protected switch unit and a transducer unit. They can be ordered separately for customer stocking and/or field assembly or as a complete factory-assembled unit. Switch P-Series pressure switch units incorporate the unique ASCO TRI-POINT alternating fulcrum balance plate to control the operation of one or more electrical snapaction swtiches. The electrical snap-action switch together with the adjusting mechanism is a fully-tested, self-contained subassembly. Standard Electrical Ratings PA, PB, PC 1 Series 15 Amp Res., 125 VAC 10 Amp Res., 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC PG Series 15 Amp Res., 125 VAC 10 Amp Res., 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC SPDT NO C NC ^% PC Series, UL recognized component, rated 10 Amp Res., 125/250 VAC; 1/3 HP 125/250 VAC. 2 Open frame construction, UL recognized component. 3 FM listed for air flow interlocking service. 1 2 # 3 Transducer Transducer unit incorporates a diaphragm/piston type pressure sensor, and is also a fully-tested, self-contained subassembly. Operation When pressure is applied to the transducer it is converted into movement of the piston. This piston movement is then used to control the operation of the electrical snap-action switch in the switch unit. Options (See pages 34-35) 8 Standard Temperature Ratings Ambient: -4°F (-20°C) to 122°F (50°C) Fluid: For Buna “N” or Neoprene Diaphragm -4°F (-20°C) to 180°F (82°C) For FKM Diaphragm -4°F (-20°C) to 250°F (121°C) For 316 SS Diaphragm -50°F (-45°C) to 300°F (149°C) For Nylon Transducers -4°F (-20°C) to 180°F (82°C) 4 123 Enclosures ASCO TRI-POINT switches are available in either a general purpose or watertight enclosure, in addition to open frame construction. These enclosed units are made in accordance with NEMA and UL standards. These standards define the protection level an enclosure gives and the tests it must pass to meet a particular design. General Purpose – Type 1. These enclosures are designed for indoor use to protect personnel from accidental contact with the equipment. P-Series general purpose enclosures are painted, zinc-coated steel and have a 7/8” diameter hole at the top for electrical entry. Watertight – Type 4. Watertight and dust-tight enclosures are intended for use indoors and outdoors to protect the enclosed equipment against splashing or falling water, windblown dust and water, hose directed water, and severe external condensation. P-Series watertight switch enclosures are epoxy-painted, zinccoated steel with a 1/2” conduit hub in the side of the lower housing for electrical entry. (For optional 316 SS watertight enclosure see page 13.) Dimensions (inches) P-Series Pressure (Mounting brackets optional) Open Frame PA and PC Switch Units with Transducer Unit 2.5 Open Frame PB and PG Switch Units with Transducer Unit .233 DIA HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) 2.5 1.8 5.5 5.2 4.9 5.7 4.6 .3 .3 1/4 OR 1/2 NPT 1/4 OR 1/2 NPT 1.5 1.5 .08 2.7 1.8 .08 1.8 2.5 2.5 2.7 .233 DIA HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) .233 DIA. HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) Type 1 General Purpose Switch Unit with Transducer Unit Type 4 Watertight Switch Unit with Transducer Unit 1.5 7/8 DIA. HOLE FOR 1/2 CONDUIT CONNECTION .9 .7 2.6 1.8 .5 ADDITIONAL SPACING REQUIRED FOR REMOVAL OF COVER .08 4.9 4.5 1.8 2.5 4.0 .223 DIA. HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) 5.4 5.7 1/2 NPT CONDUIT CONNECTION 5.2 6.2 5.2 1/4 OR 1/2 NPT 1.3 .3 .08 2.8 2.9 1.8 .233 DIA. HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) 2.5 2.0 4.0 1/4 OR 1/2 NPT .233 DIA. HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) .280 DIA. HOLES (2 PLACES) .4 .8 .08 1.8 2.03 9 4 P-SERIES Pressure Switches Select transducer unit below How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PA36A/RD30A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one PA36A and one RD30A11. Options – Add appropriate suffix for desired option or accessory (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., PA 3 6A and RD 3 0A11. How to Select and Order ASCO P-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that proof pressure is sufficient. 3. Read across and select the desired P-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. General Purpose Enclosure Select P-Series pressure switch PA Switch Unit PA, PB, or PC unit below PB Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . PC Switch Unit Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. Standard connection is 1/4” NPT (optional 1/2” NPT add suffix “B” to catalog number) Transducer Unit These guage pressure type transducers provide for one pressure connection in the bottom of the transducer. They are diaphragm/piston type transducers using an elastomer in contact with the fluid, backed by a piston cylinder. This allows high sensitivity for low pressures and strength for high pressures. Watertight Enclosure Open Frame Specifications Open Frame Open Frame Adjustable Deadband Fixed Deadband Two-Stage Fixed Deadband Adjustable Deadband Adjustable Operating Range (psig) Maximum Full Scale Proof Pressure (psig) Transducer Units Separation General Purpose Watertight Enclosure Minimum At Mid-Range Catalog (In W.C.) 1 No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 Open Frame 123 Open Frame General Purpose Watertight Enclosure Catalog No. Catalog No. Catalog No. Maximum Fixed Open Full Scale Deadband Frame At Minimum At Mid-Range Mid-Range Catalog (psig) 1 (psig) 1 No. Air or Gas 2 Air, Oil or Gas Water, Air, Oil or Gas Corrosive Fluids General Purpose Watertight Enclosure Nylon & Buna “N” Aluminum & Buna “N” Brass & Buna “N” All 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 3 316 SS & Viton 4 Vacuum 0 - 30” Hg 50 4” Hg PA36A PA30A PA31B 1” Hg PB36A PB30A PB31B 2.7” Hg 3” Hg PC36A PC30A PC31B --- RV34A11 RV34A21 --- RV34A32 50 6” Hg PA26A PA20A PA21B 1” Hg PB26A PB20A PB21B 4.3” Hg 6” Hg PC26A PC20A PC21B --- RV24A11 RV24A21 --- RV24A32 --1.2 1.8 2.5 4.0 5.4 9 18 27 36 54 90 250 300 650 --PA36A PA26A PA36A PA26A PA16A PA16A PA16A PA16A PA16A PA26A PA16A PA26A PA16A PA16A --PA30A PA20A PA30A PA20A PA10A PA10A PA10A PA10A PA10A PA20A PA10A PA20A PA10A PA10A --PA31B PA21B PA31B PA21B PA11B PA11B PA11B PA11B PA11B PA21B PA11B PA21B PA11B PA11B 0.05 0.4 0.4 0.6 0.7 0.9 1.5 3.0 5.0 6 12 15 100 125 200 PB46A PB36A PB26A PB36A PB26A PB16A PB16A PB16A PB16A PB16A PB26A PB16A PB26A PB16A PB16A PB40A PB30A PB20A PB30A PB20A PB10A PB10A PB10A PB10A PB10A PB20A PB10A PB20A PB10A PB10A PB41B PB31B PB21B PB31B PB21B PB11B PB11B PB11B PB11B PB11B PB21B PB11B PB21B PB11B PB11B --0.6 0.8 1.2 2.0 2.4 4 8 12 16 30 40 200 250 400 --1.0 1.8 1.8 3.6 6.0 10 20 30 40 60 100 300 400 600 --PC36A PC26A PC36A PC26A PC16A PC16A PC16A PC16A PC16A PC26A PC16A PC26A PC16A PC16A --PC30A PC20A PC30A PC20A PC10A PC10A PC10A PC10A PC10A PC20A PC10A PC20A PC10A PC10A -PC31B PC21B PC31B PC21B PC11B PC11B PC11B PC11B PC11B PC21B PC11B PC21B PC11B PC11B RD40A71 RD30A71 RD20A71 --RE20A71 RE10A71 RF10A71 RG10A71 --------------- RD40A11 RD30A11 RD20A11 --RE20A11 RE10A11 RF10A11 RG10A11 RH10A11 RJ10A11 ----------- RD40A21 RD30A21 RD20A21 --RE20A21 RE10A21 RF10A21 RG10A21 RH10A21 RJ10A21 RL20A21 RL10A21 RN20B21 RN10B21 --- ------RE30A44 RE20A44 RE10A44 RF10A44 RG10A44 RH10A44 RJ10A44 ----------- RD40A42 RD30A42 RD20A42 --RE20A42 RE10A42 RF10A42 RG10A42 RH10A42 RJ10A42 RL20A42 RL10A42 RN20B42 RN10B42 RQ10B42 Compound 30”Hg - 14 psig Pressure 0 0 2 2 4 6 10 20 30 40 60 100 160 270 600 - 4 9 18 18 36 60 100 200 300 400 600 1000 1650 2700 6000 60 60 60 100 150 150 200 400 450 500 2000 2000 5000 5000 9000 All switch units above are in stock for immediate delivery. 10 1 Values shown are nominal. 2 Rated proof pressure on RF10A71 is 150 psig and on RG10A71 is 300 psig. All switch units and transducer units above are in stock for immediate delivery. 3 316 SS transducer deadbands are approx. 50% greater than listed. 4 Transducers ending in 32 have 303 SS process connections, not 316 SS. 11 4 P-SERIES Pressure Switches Select transducer unit below How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PA36A/RD30A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one PA36A and one RD30A11. Options – Add appropriate suffix for desired option or accessory (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., PA 3 6A and RD 3 0A11. How to Select and Order ASCO P-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that proof pressure is sufficient. 3. Read across and select the desired P-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. General Purpose Enclosure Select P-Series pressure switch PA Switch Unit PA, PB, or PC unit below PB Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . PC Switch Unit Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. Standard connection is 1/4” NPT (optional 1/2” NPT add suffix “B” to catalog number) Transducer Unit These guage pressure type transducers provide for one pressure connection in the bottom of the transducer. They are diaphragm/piston type transducers using an elastomer in contact with the fluid, backed by a piston cylinder. This allows high sensitivity for low pressures and strength for high pressures. Watertight Enclosure Open Frame Specifications Open Frame Open Frame Adjustable Deadband Fixed Deadband Two-Stage Fixed Deadband Adjustable Deadband Adjustable Operating Range (psig) Maximum Full Scale Proof Pressure (psig) Transducer Units Separation General Purpose Watertight Enclosure Minimum At Mid-Range Catalog No. (In W.C.) 1 Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 Open Frame 123 Open Frame General Purpose Watertight Enclosure Catalog No. Catalog No. Catalog No. Maximum Fixed Open Full Scale Deadband Frame At Minimum At Mid-Range Mid-Range Catalog (psig) 1 (psig) 1 No. Air or Gas 2 Air, Oil or Gas Water, Air, Oil or Gas Corrosive Fluids General Purpose Watertight Enclosure Nylon & Buna “N” Aluminum & Buna “N” Brass & Buna “N” All 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 3 316 SS & FKM 4 Vacuum 0 - 30” Hg 50 4” Hg PA36A PA30A PA31B 1” Hg PB36A PB30A PB31B 2.7” Hg 3” Hg PC36A PC30A PC31B --- RV34A11 RV34A21 --- RV34A32 50 6” Hg PA26A PA20A PA21B 1” Hg PB26A PB20A PB21B 4.3” Hg 6” Hg PC26A PC20A PC21B --- RV24A11 RV24A21 --- RV24A32 --1.2 1.8 2.5 4.0 5.4 9 18 27 36 54 90 250 300 650 --PA36A PA26A PA36A PA26A PA16A PA16A PA16A PA16A PA16A PA26A PA16A PA26A PA16A PA16A --PA30A PA20A PA30A PA20A PA10A PA10A PA10A PA10A PA10A PA20A PA10A PA20A PA10A PA10A --PA31B PA21B PA31B PA21B PA11B PA11B PA11B PA11B PA11B PA21B PA11B PA21B PA11B PA11B 0.05 0.4 0.4 0.6 0.7 0.9 1.5 3.0 5.0 6 12 15 100 125 200 PB46A PB36A PB26A PB36A PB26A PB16A PB16A PB16A PB16A PB16A PB26A PB16A PB26A PB16A PB16A PB40A PB30A PB20A PB30A PB20A PB10A PB10A PB10A PB10A PB10A PB20A PB10A PB20A PB10A PB10A PB41B PB31B PB21B PB31B PB21B PB11B PB11B PB11B PB11B PB11B PB21B PB11B PB21B PB11B PB11B --0.6 0.8 1.2 2.0 2.4 4 8 12 16 30 40 200 250 400 --1.0 1.8 1.8 3.6 6.0 10 20 30 40 60 100 300 400 600 --PC36A PC26A PC36A PC26A PC16A PC16A PC16A PC16A PC16A PC26A PC16A PC26A PC16A PC16A --PC30A PC20A PC30A PC20A PC10A PC10A PC10A PC10A PC10A PC20A PC10A PC20A PC10A PC10A -PC31B PC21B PC31B PC21B PC11B PC11B PC11B PC11B PC11B PC21B PC11B PC21B PC11B PC11B RD40A71 RD30A71 RD20A71 --RE20A71 RE10A71 RF10A71 RG10A71 --------------- RD40A11 RD30A11 RD20A11 --RE20A11 RE10A11 RF10A11 RG10A11 RH10A11 RJ10A11 ----------- RD40A21 RD30A21 RD20A21 --RE20A21 RE10A21 RF10A21 RG10A21 RH10A21 RJ10A21 RL20A21 RL10A21 RN20B21 RN10B21 --- ------RE30A44 RE20A44 RE10A44 RF10A44 RG10A44 RH10A44 RJ10A44 ----------- RD40A42 RD30A42 RD20A42 --RE20A42 RE10A42 RF10A42 RG10A42 RH10A42 RJ10A42 RL20A42 RL10A42 RN20B42 RN10B42 RQ10B42 Compound 30”Hg - 14 psig Pressure 0 0 2 2 4 6 10 20 30 40 60 100 160 270 600 - 4 9 18 18 36 60 100 200 300 400 600 1000 1650 2700 6000 60 60 60 100 150 150 200 400 450 500 2000 2000 5000 5000 9000 All switch units above are in stock for immediate delivery. 10 1 Values shown are nominal. 2 Rated proof pressure on RF10A71 is 150 psig and on RG10A71 is 300 psig. All switch units and transducer units above are in stock for immediate delivery. 3 316 SS transducer deadbands are approx. 50% greater than listed. 4 Transducers ending in 32 have 303 SS process connections, not 316 SS. 11 P-SERIES Pressure Switches How to Select and Order ASCO P-Series switches consist of two components, the switch unit and the transducer unit. How to Select How to Order 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that rated proof pressure is sufficient. 3. Read across and select the desired P-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PG36A/RV34A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one PG36A and one RV34A11. Options – Add appropriate suffix for desired option (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., PG 3 6A and RV 3 4A11. Select P-Series switch unit and transducer unit below PG Switch Unit Transducer Unit Limited Adjustable Deadband units have an adjustable set point and use a special snap-action switch that varies the deadband within the limits listed below. These guage pressure type transducers are diaphragm/piston type transducers using an elastomer in contact with the fluid, backed by a piston cylinder. This allows high sensitivity for low pressures and strength for high pressures. Open Frame Specifications Adjustable Operating Range (psig) Standard port connection is 1/4” NPT (optional 1/2” NPT add suffix “B” to catalog number) Limited Adjustable Deadband Adjustable Deadband Open General Watertight At Frame Purpose Enclosure Mid-Range Proof (psig) 1 Catalog Catalog Catalog Pressure From/To (psig) No. No. No. Transducer Units Air or Gas 2 Air, Oil or Gas Water, Air, Oil or Gas Nylon & Aluminum Brass & Buna “N” & Buna “N” Buna “N” Corrosive Fluids All 316 SS 3 316 SS & FKM 4 Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Vacuum 0 - 30” Hg 50 1.8 - 5.0 PG36A PG30A PG31B --- RV34A11 RV34A21 --- RV34A32 50 2.8 - 6.0 PG26A PG20A PG21B --- RV24A11 RV24A21 --- RV24A32 0.7 0.8 1.8 2.0 2.1 4 8 15 22 35 65 190 200 300 PG36A PG26A PG36A PG26A PG16A PG16A PG16A PG16A PG16A PG26A PG16A PG26A PG16A PG16A PG30A PG20A PG30A PG20A PG10A PG10A PG10A PG10A PG10A PG20A PG10A PG20A PG10A PG10A PG31B PG21B PG31B PG21B PG11B PG11B PG11B PG11B PG11B PG21B PG11B PG21B PG11B PG11B RD30A71 RD20A71 --RE20A71 RE10A71 RF10A71 RG10A71 --------------- RD30A11 RD20A11 --RE20A11 RE10A11 RF10A11 RG10A11 RH10A11 RJ10A11 ----------- RD30A21 RD20A21 --RE20A21 RE10A21 RF10A21 RG10A21 RH10A21 RJ10A21 RL20A21 RL10A21 RN20B21 RN10B21 --- ----RE30A44 RE20A44 RE10A44 RF10A44 RG10A44 RH10A44 RJ10A44 ----------- RD30A42 RD20A42 --RE20A42 RE10A42 RF10A42 RG10A42 RH10A42 RJ10A42 RL20A42 RL10A42 RN10B42 RN10B42 RQ10B42 Compound 30”Hg-14 psig Pressure 0 2 2 4 6 10 20 30 40 60 100 160 270 600 - 9 18 18 36 60 100 200 300 400 600 1000 1650 2700 6000 60 60 100 150 150 200 400 450 500 2000 2000 5000 5000 9000 - 1.3 2.1 3.1 4.0 4.6 8 17 25 45 75 110 290 300 500 All switch units and transducer units above are in stock for immediate delivery. 1 3 12 Values shown are nominal. 2 Rated proof pressure on RF10A71 is 150 psig and on RG10A71 is 300 psig. 316 SS transducer deadbands are approx. 50% greater than listed. 4 Transducers ending in 32 have 303 SS process connections, not 316 SS. S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, or Differential with General Purpose, Watertight or Explosion-Proof Enclosures Features: • Set point repeatability, +1% of operating range. • All wiring terminals, adjustments and visual scales are accessible from the front of the switch. • Choice of general purpose, watertight or explosionproof enclosures. • Choice of fixed or full-range adjustable deadband. • Choice of single or two-stage units. • Manual reset units available. • Mounts in any position. • Rugged and vibration resistant. • Visual adjustment scales in psi and bars. • External adjusting nuts. • Separate electrical, pressure and adjusting chambers. • Wide selection of transducer wetted materials suitable for air, water, oil or corrosive fluids. • Mix and match switch and transducer components for increased stock flexibility or to change pressure ranges in field. Standard Electrical Ratings General Description: ASCO S-Series pressure switches consist of a switch unit and a transducer unit. They can be ordered separately for customer stocking and/or field assembly or as a complete factory-assembled unit. Switch S-Series pressure switch units incorporate the unique ASCO TRI-POINT alternating fulcrum balance plate to control the operation of one or more electrical snapaction swtiches. The electrical snap-action switch together with the adjusting mechanism is a fully-tested, self-contained subassembly. SA, SB, SC, SD and SE Series 15 Amp Res., 125 VAC 10 Amp Res., 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC SPDT NO C NC ^ % Standard Temperature Ratings Transducer Transducer unit incorporates a diaphragm/piston type pressure sensor, and is also a fully-tested, self-contained subassembly. Operation When pressure is applied to the transducer it is converted into movement of the piston. This piston movement is then used to control the operation of the electrical snap-action switch in the switch unit. 14 Ambient: -4°F (-20°C) to 140°F (60°C) Fluid: For Buna “N” or Neoprene Diaphragm -4°F (-20°C) to 180°F (82°C) For FKM Diaphragm -4°F (-20°C) to 250°F (121°C) For 316 SS Diaphragm -50°F (-45°C) to 300°F (149°C) Options (See pages 34-35) 4 123 Switches with Optional 316 Stainless Steel Enclosure Every ASCO P-Series pressure switch is available in a corrosion-resistant, stainless steel enclosure. Typical applications include: • Offshore platforms • Hydrocarbon processing plants • Oil & gas fields • Oil & gas transmission lines • Chemical plants • Breweries • Paper pulp mills • Salt spray locations Stainless Steel Enclosure ASCO Type 4X watertight enclosure is designed to provide protection against windblown dust, rain, sleet or external ice formation. The switch and transducer unit are available only as factory-assembled units, and include a UL-approved 1/2” NPT conduit hub. Dimensions (inches) How to Select and Order ASCO P-Series switches with 316 SS enclosure consist of two factory-assembled components, the switch unit and the transducer unit. P-Series Pressure with Optional 316 SS Enclosure 4.9 4.5 4.0 How to Select (use tables on pages 10-12) 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that rated proof pressure is sufficient. 3. Read across and select the desired P-Series switch unit with open frame construction. 4. To add a 316 SS enclosure, change the fourth digit of the open frame catalog number from “6” to “4”, e.g., PG3 6 A becomes PG3 4 A. 5. Continue across and select a matching transducer unit compatible with the fluid. 5.35 1.7 1/4 OR 1/2 NPT How to Order Factory assembled only – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PG34A/RV34A32. Options – Add appropriate suffix for desired option (see pages 34-35). .4 2.3 1.8 2.1 .27 DIA. 2 HOLES FOR MOUNTING 4.3 1/2 NPT CONDUIT CONNECTION NOTE: THIS DIMENSION WILL VARY FROM 5.0 MIN. TO 6.04 MAX. DEPENDING ON TRANSDUCER SPECIFIED. * MOUNTING BRACKET OPTIONAL 13 4 123 Enclosures Class I locations are those in which flammable gases are or may be present in the air in sufficient quantities to produce explosive or ignitable mixtures. Class I locations are classified by group letter, which defines particular atmospheres. Division 1 locations are areas where the hazardous concentration exists continuously, intermittently or periodically under normal operating conditions. Division 2 locations are those where the hazardous vapors are present only in case of accidental rupture or breakdown of equipment. ASCO TRI-POINT S-Series switches are available in three standard enclosures. All of these enclosed units are made in accordance with NEMA and UL standards. General Purpose – Type 1. These enclosures are designed for indoor use to protect personnel from accidental contact with the equipment. S-Series general purpose switch units consist of a copper-free* aluminum die-cast body with a formed copper-free* aluminum cover; two 3/4” conduit hubs with one plug are provided. ASCO TRI-POINT explosion-proof enclosures with letter B, C or D in the fifth position are listed for Class I, Groups B, C, and D, Division 1. They are also suitable for the less stringent Division 2 environment. Watertight – Type 4. Watertight and dust-tight enclosures are intended for use indoors and outdoors to protect the enclosed equipment against splashing or falling water, windblown dust and water, hose directed water, and severe external condensation. S-Series watertight switch units have a copper-free* aluminum die-cast body and a formed copper-free* aluminum cover with Buna “N” gaskets; two 3/4” conduit hubs with one plug are provided. Class II locations are those which are hazardous because of the presence of combustible dust. All ASCO TRI-POINT explosion-proof enclosures are listed for Groups E, F, and G locations. The switch body and cover are die-cast copper-free* aluminum with a Buna “N” gasket. Two 3/4” conduit hubs with one plug are provided. Explosion-Proof – Types 7 and 9. Type 7 enclosures are intended for use in locations defined by the National Electrical Code as Class I. Type 9 enclosures are intended for Class II locations. Dimensions (inches) S-Series Pressure With Types TD - TV Transducers With Types TA - TC Transducers 1/4 NPT VENT CONNECTION ON DOUBLE CHAMBER TRANSDUCERS 3.5 ADDITIONAL SPACE REQUIRED FOR REMOVAL OF COVER 3.7 ADDITIONAL SPACE REQUIRED FOR REMOVAL OF COVER 2.2 3.5 1.5 1.03 2.3 1.6 1.03 2.3 1.6 3/4 NPT FOR CONDUIT CONN. BOTH ENDS 3/4 NPT FOR CONDUIT CONN. BOTH ENDS 7.4 7.5 11/32 DIA. FOR MOUNTING (2PLACES) 1.0 1 11/32 DIA. FOR MOUNTING (2PLACES) 1.0 4.3 1 4.1 2.2 3.2 4.06 1.7 3.7 1/4 NPT 1/4 OR 1/2 NPT 2.9 1 7.0 ON TV SERIES ADD 7/16" TO THESE DIMENSIONS 3.2 7.0 * Less than 0.6% copper. 15 S-SERIES Pressure Switches 4 (to 8000 psig) Options – Add appropriate suffix for desired option (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., SA 4 0D and TA 4 0A11. How to Select and Order ASCO S-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that proof pressure is sufficient. 3. Read across and select the desired S-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. Select S-Series pressure switch SA Switch Unit How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., SA40D/TA40A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one SA40D and one TA40A11. Proof Pressure (psig) 0 - 12” W.C. 0 - 27” W.C. 0 - 65” W.C. 15 - 140” W.C. 15 - 250” W.C. 25 - 400” W.C. 0.4 - 4.5 0.7 - 9.0 0.8 - 9.0 1.0 - 18 1.0 - 18 1.5 - 36 2 - 60 5 - 60 3 - 100 5 - 120 5 - 200 6 - 200 13 - 300 15 - 400 30 - 600 50 - 1000 75 - 1500 200 - 3500 500 - 8000 25 25 25 40 40 40 100 100 150 100 150 150 150 3000 200 3000 3000 400 600 600 900 1500 2300 5000 9000 SC Switch Unit Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. Adjustable Deadband Standard connection is 1/4” NPT; (Optional 1/2” NPT add suffix “B” to catalog numbers TD thru TQ) Transducer Unit Explosion Proof Fixed Deadband or Manual Reset Two-Stage Fixed Deadband Adjustable Deadband Separation Maximum Full Scale Maximum Full Scale Minimum At Mid-Range Catalog (psig) 1 No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 SA40D SA30D SA20D SA20D SA10D SA10D SA40D SA30D SA40D SA20D SA30D SA20D SA10D SA30D SA10D SA20D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA41D SA31D SA21D SA21D SA11D SA11D SA41D SA31D SA41D SA21D SA31D SA21D SA11D SA31D SA11D SA21D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA42D SA32D SA22D SA22D SA12D SA12D SA42D SA32D SA42D SA22D SA32D SA22D SA12D SA32D SA12D SA22D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D 1.0” W.C. 1.2” W.C. 1.4” W.C. 3” W.C. 6” W.C. 8” W.C. 0.3 0.3 0.8 0.4 1.0 0.9 1.5 4.0 2.5 5.0 6.0 5.0 8 10 15 30 45 125 275 1.5” W.C. 2.0” W.C. 2.5” W.C. 6” W.C. 10” W.C. 15” W.C. 0.4 0.6 1.4 1.1 1.6 2.2 3.6 6.0 6.0 10 14 12 18 24 36 75 115 225 450 General Watertight ExplosionPurpose Enclosure Proof 1 Values shown are nominal. Series TD-TQ These guage pressure type transducers provide for one pressure connection in the bottom of the transducer. They are diaphragm/piston type transducers using an elastomer in contact with the fluid, backed by a piston cylinder. This allows high sensitivity for low pressures and strength for high pressures. Catalog No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 SB40D SB30D SB20D SB20D SB10D SB10D SB40D SB30D SB40D SB20D SB30D SB20D SB10D SB30D SB10D SB20D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB41D SB31D SB21D SB21D SB11D SB11D SB41D SB31D SB41D SB21D SB31D SB21D SB11D SB31D SB11D SB21D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB42D SB32D SB22D SB22D SB12D SB12D SB42D SB32D SB42D SB22D SB32D SB22D SB12D SB32D SB12D SB22D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D 1.2” W.C. 1.4” W.C. 1.6” W.C. 4.0” W.C. 7.0” W.C. 13.0” W.C. 0.4 0.4 1.0 0.6 1.2 1.4 2.2 5.5 3.5 7.0 8.5 7.0 10 14 20 40 60 150 300 General Watertight ExplosionPurpose Enclosure Proof All switch units above are in stock for immediate delivery. 16 Series TA-TC General Purpose Specifications Adjustable Operating Range (psig) SB Switch Unit: Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. SD Switch Unit: Manual reset on decreasing pressure units operate automatically on increasing pressure and must be reset manually on decreasing pressure. (To order, change second digit to letter “D”, e.g., S B 40D becomes S D 40D). SE Switch Unit: Manual reset on increasing pressure units operate automatically on decreasing pressure and must be reset manually on increasing pressure. (To order, change second digit to letter “E”, e.g., S B 40D becomes S E 40D). Select transducer unit below SA, SB, SC, SD and SE unit below SB, SD or SE Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . 123 Minimum At Mid-Range (psig) 1 2.4” W.C. 2.7” W.C. 6.5” W.C. 14” W.C. 25” W.C. 40” W.C. 0.7 0.9 1.6 1.8 1.8 3.6 6 8 10 12 20 20 30 40 60 100 150 350 800 Transducer Units Air, Oil or Gas Water, Air Oil or Gas Corrosive Fluids General Purpose Watertight Enclosure ExplosionProof Aluminum & Buna “N” Brass & Buna “N” All 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. SC40D SC30D SC20D SC20D SC10D SC10D SC40D SC30D SC40D SC20D SC30D SC20D SC10D SC30D SC10D SC20D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC41D SC31D SC21D SC21D SC11D SC11D SC41D SC31D SC41D SC21D SC31D SC21D SC11D SC31D SC11D SC21D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC42D SC32D SC22D SC22D SC12D SC12D SC42D SC32D SC42D SC22D SC32D SC22D SC12D SC32D SC12D SC22D SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D TA40A11 TA30A11 TA20A11 TB20A11 TB10A11 TC10A11 TD40A11 TD30A11 --TD20A11 --TE20A11 TE10A11 --TE10A11 ----TG10A11 TH10A11 TJ10A11 ----------- ------------TD40A21 TD30A21 --TD20A21 --TE20A21 TE10A21 --TF10A21 ----TG10A21 TH10A21 TJ10A21 TK10A21 TL10A21 TM10A21 TN10B21 --- ----------------TE40A44 --TE30A44 TE20A44 TE10A44 --TF10A44 ----TG10A44 TH10A44 TJ10A44 ----------- TA40A32 TA30A32 TA20A32 TB20A32 TB10A32 TC10A32 TD40A42 TD30A42 --TD20A42 --TE20A42 TE10A42 TG33A42 TF10A42 TG23A42 TG13A42 TG10A42 TH10A42 TJ10A42 TK10A42 TL10A42 TM10A42 TN10B42 TQ10B42 2 316 SS & Viton 3 All switch units and transducer units above are in stock for immediate delivery. 2 316 SS transducers increase deadband by 50%. 3 Transducers ending in 32 have 303 SS process connections, not 316 SS. 17 S-SERIES Pressure Switches 4 (to 8000 psig) Options – Add appropriate suffix for desired option (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., SA 4 0D and TA 4 0A11. How to Select and Order ASCO S-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that proof pressure is sufficient. 3. Read across and select the desired S-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. Select S-Series pressure switch SA Switch Unit How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., SA40D/TA40A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one SA40D and one TA40A11. Proof Pressure (psig) 0 - 12” W.C. 0 - 27” W.C. 0 - 65” W.C. 15 - 140” W.C. 15 - 250” W.C. 25 - 400” W.C. 0.4 - 4.5 0.7 - 9.0 0.8 - 9.0 1.0 - 18 1.0 - 18 1.5 - 36 2 - 60 5 - 60 3 - 100 5 - 120 5 - 200 6 - 200 13 - 300 15 - 400 30 - 600 50 - 1000 75 - 1500 200 - 3500 500 - 8000 25 25 25 40 40 40 100 100 150 100 150 150 150 3000 200 3000 3000 400 600 600 900 1500 2300 5000 9000 SC Switch Unit Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. Adjustable Deadband Standard connection is 1/4” NPT; (Optional 1/2” NPT add suffix “B” to catalog numbers TD thru TQ) Transducer Unit Explosion Proof Fixed Deadband or Manual Reset Two-Stage Fixed Deadband Adjustable Deadband Separation Maximum Full Scale Maximum Full Scale Minimum At Mid-Range Catalog (psig) 1 No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 SA40D SA30D SA20D SA20D SA10D SA10D SA40D SA30D SA40D SA20D SA30D SA20D SA10D SA30D SA10D SA20D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA41D SA31D SA21D SA21D SA11D SA11D SA41D SA31D SA41D SA21D SA31D SA21D SA11D SA31D SA11D SA21D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA42D SA32D SA22D SA22D SA12D SA12D SA42D SA32D SA42D SA22D SA32D SA22D SA12D SA32D SA12D SA22D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D 1.0” W.C. 1.2” W.C. 1.4” W.C. 3” W.C. 6” W.C. 8” W.C. 0.3 0.3 0.8 0.4 1.0 0.9 1.5 4.0 2.5 5.0 6.0 5.0 8 10 15 30 45 125 275 1.5” W.C. 2.0” W.C. 2.5” W.C. 6” W.C. 10” W.C. 15” W.C. 0.4 0.6 1.4 1.1 1.6 2.2 3.6 6.0 6.0 10 14 12 18 24 36 75 115 225 450 General Watertight ExplosionPurpose Enclosure Proof 1 Values shown are nominal. Series TD-TQ These guage pressure type transducers provide for one pressure connection in the bottom of the transducer. They are diaphragm/piston type transducers using an elastomer in contact with the fluid, backed by a piston cylinder. This allows high sensitivity for low pressures and strength for high pressures. Catalog No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 SB40D SB30D SB20D SB20D SB10D SB10D SB40D SB30D SB40D SB20D SB30D SB20D SB10D SB30D SB10D SB20D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB41D SB31D SB21D SB21D SB11D SB11D SB41D SB31D SB41D SB21D SB31D SB21D SB11D SB31D SB11D SB21D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB42D SB32D SB22D SB22D SB12D SB12D SB42D SB32D SB42D SB22D SB32D SB22D SB12D SB32D SB12D SB22D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D 1.2” W.C. 1.4” W.C. 1.6” W.C. 4.0” W.C. 7.0” W.C. 13.0” W.C. 0.4 0.4 1.0 0.6 1.2 1.4 2.2 5.5 3.5 7.0 8.5 7.0 10 14 20 40 60 150 300 General Watertight ExplosionPurpose Enclosure Proof All switch units above are in stock for immediate delivery. 16 Series TA-TC General Purpose Specifications Adjustable Operating Range (psig) SB Switch Unit: Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. SD Switch Unit: Manual reset on decreasing pressure units operate automatically on increasing pressure and must be reset manually on decreasing pressure. (To order, change second digit to letter “D”, e.g., S B 40D becomes S D 40D). SE Switch Unit: Manual reset on increasing pressure units operate automatically on decreasing pressure and must be reset manually on increasing pressure. (To order, change second digit to letter “E”, e.g., S B 40D becomes S E 40D). Select transducer unit below SA, SB, SC, SD and SE unit below SB, SD or SE Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . 123 Minimum At Mid-Range (psig) 1 2.4” W.C. 2.7” W.C. 6.5” W.C. 14” W.C. 25” W.C. 40” W.C. 0.7 0.9 1.6 1.8 1.8 3.6 6 8 10 12 20 20 30 40 60 100 150 350 800 Transducer Units Air, Oil or Gas Water, Air Oil or Gas Corrosive Fluids General Purpose Watertight Enclosure ExplosionProof Aluminum & Buna “N” Brass & Buna “N” All 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. SC40D SC30D SC20D SC20D SC10D SC10D SC40D SC30D SC40D SC20D SC30D SC20D SC10D SC30D SC10D SC20D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC41D SC31D SC21D SC21D SC11D SC11D SC41D SC31D SC41D SC21D SC31D SC21D SC11D SC31D SC11D SC21D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC42D SC32D SC22D SC22D SC12D SC12D SC42D SC32D SC42D SC22D SC32D SC22D SC12D SC32D SC12D SC22D SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D TA40A11 TA30A11 TA20A11 TB20A11 TB10A11 TC10A11 TD40A11 TD30A11 --TD20A11 --TE20A11 TE10A11 --TE10A11 ----TG10A11 TH10A11 TJ10A11 ----------- ------------TD40A21 TD30A21 --TD20A21 --TE20A21 TE10A21 --TF10A21 ----TG10A21 TH10A21 TJ10A21 TK10A21 TL10A21 TM10A21 TN10B21 --- ----------------TE40A44 --TE30A44 TE20A44 TE10A44 --TF10A44 ----TG10A44 TH10A44 TJ10A44 ----------- TA40A32 TA30A32 TA20A32 TB20A32 TB10A32 TC10A32 TD40A42 TD30A42 --TD20A42 --TE20A42 TE10A42 TG33A42 TF10A42 TG23A42 TG13A42 TG10A42 TH10A42 TJ10A42 TK10A42 TL10A42 TM10A42 TN10B42 TQ10B42 2 316 SS & FKM 3 All switch units and transducer units above are in stock for immediate delivery. 2 316 SS transducers increase deadband by 50%. 3 Transducers ending in 32 have 303 SS process connections, not 316 SS. 17 4 S-SERIES Vacuum, Differential Switches Options – Add appropriate suffix for desired option How to Select and Order (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., SA 3 0D and TA 3 4A11. ASCO S-Series switches consist of two components, the switch unit and the transducer unit. How to Select Select S-Series pressure switch 1. Select the adjustable operating range based on desired actuation point. 2. Check that proof pressure is sufficient. 3. Read across and select the desired S-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. SA Switch Unit Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., SA30D/TA34A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one SA30D and one TA34A11. SA, SB, SC, SD and SE unit below SB, SD or SE Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . How to Order SB Switch Unit: Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. SD Switch Unit: Manual reset on decreasing pressure units operate automatically on increasing pressure and must be reset manually on decreasing pressure. (To order, change second digit to letter “D”, e.g., S B 30D becomes S D 30D). SE Switch Unit: Manual reset on increasing pressure units operate automatically on decreasing pressure and must be reset manually on increasing pressure. (To order, change second digit to letter “E”, e.g., S B 30D becomes S E 30D). SC Switch Unit Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. Specifications Adjustable Deadband Fixed Deadband or Manual Reset Proof Pressure (psig) 50 50 15 15 25 25 25 15 15 15 25 25 25 Catalog No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (In W.C.) 1 2 - 28” Hg 3 - 57” Hg 2 - 27 3 - 65 6 - 125 10 - 235 15 - 375 SA30D SA20D SA30D SA20D SA20D SA10D SA10D SA31D SA21D SA31D SA21D SA21D SA11D SA11D SA32D SA22D SA32D SA22D SA22D SA12D SA12D 2 2 3 6 10 15 SA40D SA30D SA20D SA20D SA10D SA10D SA41D SA31D SA21D SA21D SA11D SA11D SA42D SA32D SA22D SA22D SA12D SA12D General ExplosionPurpose Watertight Proof The vacuum transducer has a spring which preloads the switch unit when no vacuum is applied. On application, the vacuum acts on a piston area to overcome the spring to operate the switch unit. Vacuum Transducer The differential pressure transducer has two pressure sources acting on the piston area in opposite directions. The force output is proportional to the difference between these pressures, allowing the differential pressure to be contolled by adjustment of the switch unit. Differential Pressure Transducer Two-Stage Fixed Deadband Transducer Units Separation Adjustable Deadband At Mid-Range (In W.C.) 1 From/To Select transducer unit below Explosion Proof General Purpose Adjustable Operating Range (In W.C.) 123 General ExplosionPurpose Watertight Proof Maximum Fixed Full Scale Deadband At Minimum At Mid-Range Mid-Range (In W.C.) 1 (In W.C.) 1 Air or Gas Water, Air Oil or Gas Corrosive Fluids General Purpose ExplosionProof Aluminum & Buna “N” Brass & Buna “N” 303 SS & Watertight Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. FKM Catalog No. Catalog No. Catalog No. 1.2” Hg 1.7” Hg 1.2 1.4 3.0 6.0 8.0 SB30D SB20D SB30D SB20D SB20D SB10D SB10D SB31D SB21D SB31D SB21D SB21D SB11D SB11D SB32D SB22D SB32D SB22D SB22D SB12D SB12D 1.7” Hg 2.0” Hg 1.7 2.0 4.0 7.0 13.0 3” Hg 8” Hg 2.7 6.5 14.0 25.0 40.0 SC30D SC20D SC30D SC20D SC20D SC10D SC10D SC31D SC21D SC31D SC21D SC21D SC11D SC11D SC32D SC22D SC32D SC22D SC22D SC12D SC12D TV34A11 TV24A11 TA31A11 TA21A11 TB21A11 TB11A11 TC11A11 TV34A21 TV24A21 ----------- TV34A32 TV24A32 ----------- 1.0 1.2 1.4 3.0 6.0 8.0 SB40D SB30D SB20D SB20D SB10D SB10D SB41D SB31D SB21D SB21D SB11D SB11D SB42D SB32D SB22D SB22D SB12D SB12D 1.4 1.7 2.0 4.0 7.0 13.0 2.4 2.7 6.5 14.0 25.0 40.0 SC40D SC30D SC20D SC20D SC10D SC10D SC41D SC31D SC21D SC21D SC11D SC11D SC42D SC32D SC22D SC22D SC12D SC12D TA41A11 TA31A11 TA21A11 TB21A11 TB11A11 TC11A11 ------------- ------------- Vacuum 0 15 PSI 0 0 15 15 25 - 30” Hg 30” Hg 27 65 140 250 400 Differential 0 0 0 15 15 25 - 12 27 65 140 250 400 - 12 27 65 125 235 375 All switch units above are in stock for immediate delivery. 1 18 All switch units and transducer units above are in stock for immediate delivery. Values shown are nominal. 19 S-SERIES Combustion Switches Pressure Switches Designed to UL or FM Requirements for Combustion Service Features: Set point repeatability, +1% of operating range. UL Listed in the gas and oil equipment list. FM Approved as “pressure supervisory switches.” Externally visible pressure setting scales. External adjusting nuts. Choice of fixed or full-range adjustable deadbands. Choice of single or two-stage units. Mounts in any position. Rugged and vibration resistant. Separate electrical, pressure and adjusting chambers. • Mix and match switch and transducer components for increased stock flexibility or to change pressure ranges in field. • Withstands high surge pressures. • • • • • • • • • • General Description: ASCO S-Series combustion switches consist of a switch unit and a transducer unit. They can be ordered separately for customer stocking and/or field assembly or as a complete factory-assembled unit. Switch S-Series combustion switch units incorporate the unique ASCO TRI-POINT alternating fulcrum balance plate to control the operation of one or more electrical snap-action swtiches. The electrical snap-action switch together with the adjusting mechanism is a fully-tested, self-contained subassembly. Transducer Transducer unit incorporates a diaphragm/piston type pressure sensor, and is also a fully-tested, self-contained subassembly. Standard Electrical Ratings SA, SD and SE Series 1 5 Amp Res., 125, 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC SB and SC Series 5 Amp Res., 125, 250 VAC 1/4 HP, 125 VAC 1/2 HP, 250 VAC .4 Amp Res., 125, VDC 1 Operation When pressure is applied to the transducer it is converted into movement of the piston. This piston movement is then used to control the operation of the electrical snap-action switch in the switch unit. Options (See pages 34-35) Dimensions (See page 15) 20 SPDT NO C NC ^# SD and SE Series not FM Approved. Standard Temperature Ratings Ambient: -4°F (-20°C) to 140°F (60°C) Fluid: For Buna “N” or Neoprene Diaphragm -4°F (-20°C) to 180°F (82°C) For FKM Diaphragm -4°F (-20°C) to 250°F (121°C) For 316 SS Diaphragm -50°F (-45°C) to 300°F (149°C) 4 UL Requirements Underwriters’ Laboratories, Inc.’s Standard UL 353 defines construction and performance requirements for limit controls. Switch S-Series combustion switch units when mated to the pressure transducers described below form pressure switches in accordance with UL requirements. Transducers Fuel Gas – UL requires a pressure transducer with a secondary chamber. This chamber allows the gas to be vented to a safe location in the event of primary sensing element rupture. The “double chamber” with vent pressure transducers meet this requirement. Fuel Oil – UL requirements for fuel oil applications waive the double chamber requirement, providing the sensing element is made of Type 316 or 321 SS. S-Series type 316 SS pressure transducers are designed to meet this requirement. General Service – Pressure transducers for water, steam and air service may be of the single chamber design. Enclosures ASCO TRI-POINT S-Series switches are available in three standard enclosures. All of these enclosed units are made in accordance with NEMA and UL standards. General Purpose – Type 1. These enclosures are designed for indoor use to protect personnel from accidental contact with the equipment. S-Series general purpose switch units consist of a copper-free* aluminum die-cast body with a formed copper-free* aluminum cover; two 3/4” conduit hubs with one plug are provided. Watertight – Type 4. Watertight and dust-tight enclosures are intended for use indoors and outdoors to protect the enclosed equipment against splashing or falling water, windblown dust and water, hose directed water, and severe external condensation. S-Series watertight switch units have a copper-free* aluminum die-cast body and a formed copper-free* aluminum cover with Buna “N” gaskets; two 3/4” conduit hubs with one plug are provided. 123 Class I locations are those in which flammable gases are or may be present in the air in sufficient quantities to produce explosive or ignitable mixtures. Class I locations are classified by group letter, which defines particular atmospheres. Division 1 locations are areas where the hazardous concentration exists continuously, intermittently or periodically under normal operating conditions. Division 2 locations are those where the hazardous vapors are present only in case of accidental rupture or breakdown of equipment. ASCO TRI-POINT explosion-proof enclosures with letter B, C or D in the fifth position are listed for Class I, Groups B, C, and D, Division 1. They are also suitable for the less stringent Division 2 environment. Class II locations are those which are hazardous because of the presence of combustible dust. All ASCO TRI-POINT explosion-proof enclosures are listed for Groups E, F, and G locations. The switch body and cover are die-cast copper-free* aluminum with a Buna “N” gasket. Two 3/4” conduit hubs with one plug are provided. FM Requirements Fuel Gas and Fuel Oil – FM requires that fuel gas and fuel oil pressure supervisory switches shall have a visible external means of determining switch position. No specific constructions are required for the pressure transducer. Switch units with visual position indication (suffix “V”) in conjunction with single chamber pressure transducers will meet these requirements. General Service – Standard switch units with an adjusting nut cover, when mated to single chamber transducers, meet FM requirements for general applications such as “airflow interlocking switches”. Enclosures General Purpose – Designed to Type 1 specifications for indoor applications. Die casting is copper-free* aluminum; covers are polycarbonate. Two 3/4” conduit hubs with one plug are provided. Watertight – Designed to Types 4 specifications for indoor/outdoor use. Die casting is copper-free* aluminum. Cover are polycarbonate and gaskets are Explosion-Proof – Types 7 and 9. Type 7 enclosures neoprene. Two 3/4” conduit hubs with one plug are are intended for use in locations defined by the National provided. Electrical Code as Class I. Type 9 enclosures are intended for Class II locations. * Less than 0.6% copper. 21 Options – Add appropriate suffix for desired option How to Select and Order (see pages 34-35). ASCO S-Series switches consist of two components, the switch unit and the transducer unit. Important Note: The third digit of each of the catalog How to Select numbers must be identical, e.g., SA 3 0D and TA 3 1A11. 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that proof pressure is sufficient. 3. Read across and select the desired S-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. Select S-Series pressure switch SA Switch Unit How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., SA30D/TA31A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one SA30D and one TA31A11. Specifications Adjustable Operating Range (psig) SA, SB, SC, SD and SE unit below SB, SD or SE Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . SC Switch Unit Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. SB Switch Unit: Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. SD Switch Unit: Manual reset on decreasing pressure units operate automatically on increasing pressure and must be reset manually on decreasing pressure. (To order, change second digit to letter “D”, e.g., S B 30D becomes S D 30D). SE Switch Unit: Manual reset on increasing pressure units operate automatically on decreasing pressure and must be reset manually on increasing pressure. (To order, change second digit to letter “E”, e.g., S B 30D becomes S E 30D). Adjustable Deadband Maximum Full Scale Fixed Deadband or Manual Reset Catalog No. Catalog No. Catalog No. 2.0” W.C. 2.5” W.C. 6.0” W.C. 10.0” W.C. 15.0” W.C. 1.4 4.6 4.0 3.3 5.4 5.0 9.0 SA30D SA20D SA20D SA10D SA10D SA40D SA30D SA30D SA20D SA10D SA20D SA10D SA31D SA21D SA21D SA11D SA11D SA41D SA31D SA31D SA21D SA11D SA21D SA11D SA32D SA22D SA22D SA12D SA12D SA42D SA32D SA32D SA22D SA12D SA22D SA12D 1.5” W.C. 2.0” W.C. 2.5” W.C. 6.0” W.C. 10.0” W.C. 1 5.0” W.C. 0.4 0.6 1.1 2.2 3.6 6.0 SA40DV SA30DV SA20DV SA20DV SA10DV SA10DV SA40DV SA30DV SA20DV SA20DV SA10DV SA10DV SA41DV SA31DV SA21DV SA21DV SA11DV SA11DV SA41DV SA31DV SA21DV SA21DV SA11DV SA11DV ------------------------- Minimum At Mid-Range (psig) 1 15 15 25 25 25 150 150 200 150 150 200 200 25 25 25 40 40 40 100 100 100 150 150 200 Standard connection is 1/4” NPT Transducer Unit - 27” W.C. 65” W.C. 140” W.C. 250” W.C. 400” W.C. 9.0 18 30 36 60 60 100 These guage pressure type transducers provide for one pressure connection in the bottom of the transducer. They are diaphragm/piston type transducers using an elastomer in contact with the fluid, backed by a piston cylinder. UL requires a double chamber transducer for fuel gas service and single chamber 316 SS transducer for fuel oil service. Two-Stage Fixed Deadband 2 Transducer Units General Watertight ExplosionPurpose Enclosure Proof Maximum Full Scale Catalog No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 1.2” W.C. 1.4” W.C. 3.0” W.C. 6.0” W.C. 8.0” W.C. 0.9 0.6 1.5 1.4 2.3 2.0 3.7 SB30D SB20D SB20D SB10D SB10D SB40D SB30D SB30D SB20D SB10D SB20D SB10D SB31D SB21D SB21D SB11D SB11D SB41D SB31D SB31D SB21D SB11D SB21D SB11D SB32D SB22D SB22D SB12D SB12D SB42D SB32D SB32D SB22D SB12D SB22D SB12D 1.7” W.C. 2.0” W.C. 4.0” W.C. 7.0” W.C. 13.0” W.C. 1.5 1.0 2.0 2.0 3.5 3.0 5.0 2.7” W.C. 6.5” W.C. 14.0” W.C. 25.0” W.C. 40.0” W.C. 1.6 1.8 3.0 3.6 6.0 6.0 10.0 SC30D SC20D SC20D SC10D SC10D SC40D SC30D SC30D SC20D SC10D SC20D SC10D SC31D SC21D SC21D SC11D SC11D SC41D SC31D SC31D SC21D SC11D SC21D SC11D SC32D SC22D SC22D SC12D SC12D SC42D SC32D SC32D SC22D SC12D SC22D SC12D TA31A11 TA21A11 TB21A11 TB11A11 TC11A11 --------------- 1.0” W.C. 1.2” W.C. 1.4” W.C. 3.0” W.C. 6.0” W.C. 8.0” W.C. 0.3 0.3 0.4 0.9 1.5 2.5 SB40DV SB30DV SB20DV SB20DV SB10DV SB10DV SB40DV SB30DV SB20DV SB20DV SB10DV SB10DV SB41DV SB31DV SB21DV SB21DV SB11DV SB11DV SB41DV SB31DV SB21DV SB21DV SB11DV SB11DV ------------------------- 1.4” W.C. 1.7” W.C. 2.0” W.C. 4.0” W.C. 7.0” W.C. 13.0” W.C. 0.5 0.5 0.5 1.2 2.1 3.5 2.4” W.C. 2.7” W.C. 6.5” W.C. 14.0” W.C. 25.0” W.C. 40.0” W.C. 0.7 0.9 1.8 3.6 6.0 10.0 SC40DV SC30DV SC20DV SC20DV SC10DV SC10DV SC40DV SC30DV SC20DV SC20DV SC10DV SC10DV SC41DV SC31DV SC21DV SC21DV SC11DV SC11DV SC41DV SC31DV SC21DV SC21DV SC11DV SC11DV ------------------------- TA40A11F TA30A11F TA20A11F TB20A11 TB10A11 TC10A11 TD40A11 TD30A11 TD20A11 TE20A11 TE10A11 TF10A11 General Watertight ExplosionPurpose Enclosure Proof Minimum At Mid-Range (psig) 1 General Purpose Watertight Enclosure ExplosionProof Aluminum & Buna “N” Brass & Buna “N” All 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Fuel Gas FM Approved 2 2 2 15 15 25 0.4 0.8 1.0 1.5 2.0 3.0 1 22 - 12” W.C. 27” W.C. 65” W.C. 140” W.C. 250” W.C. 400” W.C. 4.5 9.0 18 36 60 100 FM Approved Separation Fixed Deadband At Mid-Range (psig.) 1 Proof Pressure (psig) UL Listed FM General Purpose UL General Purpose Adjustable Deadband Select transducer unit below UL Listed 0 0 15 15 25 0.8 1.0 1.5 1.5 2.0 2.0 3.0 123 4 S-SERIES Combustion Switches --------------TF32A21 ----TF22A21 TF12A21 3 316 SS & Viton 4 Catalog No. Fuel Oil ------------------------- ----------TE40A44 TE30A44 --TE20A44 TE10A44 --TF10A44 Fuel Gas and Fuel Oil Values shown are nominal. 2 Manual reset units not available for FM. 3 316 SS transducers increase deadband by 50%. 4 ------------TD40A21 TD30A21 TD20A21 TE20A21 TE10A21 TF10A21 ------------------------- TA40A32F TA30A32F TA20A32F TB20A32 TB10A32 TC10A32 TD40A42 TD30A42 TD20A42 TE20A42 TE10A42 TF10A42 Transducers ending in 32 have 303 SS process connections, not 316 SS. 23 Options – Add appropriate suffix for desired option How to Select and Order (see pages 34-35). ASCO S-Series switches consist of two components, the switch unit and the transducer unit. Important Note: The third digit of each of the catalog How to Select numbers must be identical, e.g., SA 3 0D and TA 3 1A11. 1. Select the adjustable operating range based on desired actuation pressure. 2. Check that proof pressure is sufficient. 3. Read across and select the desired S-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit compatible with the fluid. Select S-Series pressure switch SA Switch Unit How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., SA30D/TA31A11. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one SA30D and one TA31A11. Specifications Adjustable Operating Range (psig) SA, SB, SC, SD and SE unit below SB, SD or SE Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . SC Switch Unit Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. SB Switch Unit: Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. SD Switch Unit: Manual reset on decreasing pressure units operate automatically on increasing pressure and must be reset manually on decreasing pressure. (To order, change second digit to letter “D”, e.g., S B 30D becomes S D 30D). SE Switch Unit: Manual reset on increasing pressure units operate automatically on decreasing pressure and must be reset manually on increasing pressure. (To order, change second digit to letter “E”, e.g., S B 30D becomes S E 30D). Adjustable Deadband Maximum Full Scale Fixed Deadband or Manual Reset Catalog No. Catalog No. Catalog No. 2.0” W.C. 2.5” W.C. 6.0” W.C. 10.0” W.C. 15.0” W.C. 1.4 4.6 4.0 3.3 5.4 5.0 9.0 SA30D SA20D SA20D SA10D SA10D SA40D SA30D SA30D SA20D SA10D SA20D SA10D SA31D SA21D SA21D SA11D SA11D SA41D SA31D SA31D SA21D SA11D SA21D SA11D SA32D SA22D SA22D SA12D SA12D SA42D SA32D SA32D SA22D SA12D SA22D SA12D 1.5” W.C. 2.0” W.C. 2.5” W.C. 6.0” W.C. 10.0” W.C. 1 5.0” W.C. 0.4 0.6 1.1 2.2 3.6 6.0 SA40DV SA30DV SA20DV SA20DV SA10DV SA10DV SA40DV SA30DV SA20DV SA20DV SA10DV SA10DV SA41DV SA31DV SA21DV SA21DV SA11DV SA11DV SA41DV SA31DV SA21DV SA21DV SA11DV SA11DV ------------------------- Minimum At Mid-Range (psig) 1 15 15 25 25 25 150 150 200 150 150 200 200 25 25 25 40 40 40 100 100 100 150 150 200 Standard connection is 1/4” NPT Transducer Unit - 27” W.C. 65” W.C. 140” W.C. 250” W.C. 400” W.C. 9.0 18 30 36 60 60 100 These guage pressure type transducers provide for one pressure connection in the bottom of the transducer. They are diaphragm/piston type transducers using an elastomer in contact with the fluid, backed by a piston cylinder. UL requires a double chamber transducer for fuel gas service and single chamber 316 SS transducer for fuel oil service. Two-Stage Fixed Deadband 2 Transducer Units General Watertight ExplosionPurpose Enclosure Proof Maximum Full Scale Catalog No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (psig) 1 1.2” W.C. 1.4” W.C. 3.0” W.C. 6.0” W.C. 8.0” W.C. 0.9 0.6 1.5 1.4 2.3 2.0 3.7 SB30D SB20D SB20D SB10D SB10D SB40D SB30D SB30D SB20D SB10D SB20D SB10D SB31D SB21D SB21D SB11D SB11D SB41D SB31D SB31D SB21D SB11D SB21D SB11D SB32D SB22D SB22D SB12D SB12D SB42D SB32D SB32D SB22D SB12D SB22D SB12D 1.7” W.C. 2.0” W.C. 4.0” W.C. 7.0” W.C. 13.0” W.C. 1.5 1.0 2.0 2.0 3.5 3.0 5.0 2.7” W.C. 6.5” W.C. 14.0” W.C. 25.0” W.C. 40.0” W.C. 1.6 1.8 3.0 3.6 6.0 6.0 10.0 SC30D SC20D SC20D SC10D SC10D SC40D SC30D SC30D SC20D SC10D SC20D SC10D SC31D SC21D SC21D SC11D SC11D SC41D SC31D SC31D SC21D SC11D SC21D SC11D SC32D SC22D SC22D SC12D SC12D SC42D SC32D SC32D SC22D SC12D SC22D SC12D TA31A11 TA21A11 TB21A11 TB11A11 TC11A11 --------------- 1.0” W.C. 1.2” W.C. 1.4” W.C. 3.0” W.C. 6.0” W.C. 8.0” W.C. 0.3 0.3 0.4 0.9 1.5 2.5 SB40DV SB30DV SB20DV SB20DV SB10DV SB10DV SB40DV SB30DV SB20DV SB20DV SB10DV SB10DV SB41DV SB31DV SB21DV SB21DV SB11DV SB11DV SB41DV SB31DV SB21DV SB21DV SB11DV SB11DV ------------------------- 1.4” W.C. 1.7” W.C. 2.0” W.C. 4.0” W.C. 7.0” W.C. 13.0” W.C. 0.5 0.5 0.5 1.2 2.1 3.5 2.4” W.C. 2.7” W.C. 6.5” W.C. 14.0” W.C. 25.0” W.C. 40.0” W.C. 0.7 0.9 1.8 3.6 6.0 10.0 SC40DV SC30DV SC20DV SC20DV SC10DV SC10DV SC40DV SC30DV SC20DV SC20DV SC10DV SC10DV SC41DV SC31DV SC21DV SC21DV SC11DV SC11DV SC41DV SC31DV SC21DV SC21DV SC11DV SC11DV ------------------------- TA40A11F TA30A11F TA20A11F TB20A11 TB10A11 TC10A11 TD40A11 TD30A11 TD20A11 TE20A11 TE10A11 TF10A11 General Watertight ExplosionPurpose Enclosure Proof Minimum At Mid-Range (psig) 1 General Purpose Watertight Enclosure ExplosionProof Aluminum & Buna “N” Brass & Buna “N” All 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Fuel Gas FM Approved 2 2 2 15 15 25 0.4 0.8 1.0 1.5 2.0 3.0 1 22 - 12” W.C. 27” W.C. 65” W.C. 140” W.C. 250” W.C. 400” W.C. 4.5 9.0 18 36 60 100 FM Approved Separation Fixed Deadband At Mid-Range (psig.) 1 Proof Pressure (psig) UL Listed FM General Purpose UL General Purpose Adjustable Deadband Select transducer unit below UL Listed 0 0 15 15 25 0.8 1.0 1.5 1.5 2.0 2.0 3.0 123 4 S-SERIES Combustion Switches --------------TF32A21 ----TF22A21 TF12A21 3 316 SS & FKM 4 Catalog No. Fuel Oil ------------------------- ----------TE40A44 TE30A44 --TE20A44 TE10A44 --TF10A44 Fuel Gas and Fuel Oil Values shown are nominal. 2 Manual reset units not available for FM. 3 316 SS transducers increase deadband by 50%. 4 ------------TD40A21 TD30A21 TD20A21 TE20A21 TE10A21 TF10A21 ------------------------- TA40A32F TA30A32F TA20A32F TB20A32 TB10A32 TC10A32 TD40A42 TD30A42 TD20A42 TE20A42 TE10A42 TF10A42 Transducers ending in 32 have 303 SS process connections, not 316 SS. 23 P-SERIES Temperature Switches Switches for -60 through 510°F with Adjustable Set Points and Fixed or Adjustable Deadband Features: • Set point repeatability, +1°F (1/2°C). • All wiring terminals, adjustments and visual scales are accessible from the front of the switch. • Choice of open frame type, general purpose, or watertight enclosure. • Choice of fixed, limited adjustable or full-range adjustable deadband. • Choice of single or two-stage units. • Compact size. • Mounts in any position. • Rugged and vibration resistant. • Visual adjustment scales in °F and °C. • Direct mount (local) or capillary and bulb (remote) sensors. • Temperature transducers available with copper or 316 SS wetted material. • Withstands high overrange temperatures. • Mix and match switch and transducer components for increased stock flexibility or to change pressure ranges in field. General Description: ASCO P-Series temperature switches consist of an open frame or enclosure protected switch unit and a transducer unit. They can be ordered separately for customer stocking and/or field assembly or as a complete factory-assembled unit. Switch P-Series temperature switch units incorporate the unique ASCO TRI-POINT alternating fulcrum balance plate to control the operation of one or more electrical snap-action swtiches. The electrical snap-action switch together with the adjusting mechanism is a fully-tested, self-contained subassembly. Transducer The temperature transducer unit uses a vapor pressure principle where the internal pressure within the unit is generated by the vapor pressure of a chemical within a sealed system. Temperature transducers are available in two constructions, a direct mount or capillary and bulb construction. The direct mount unit includes a 1/2” NPT connection for direct mounting to the process. The capillary and bulb construction allows remote mounting from the process. The transducer unit (like the switch unit) is a fully-tested, self-contained subassembly. 24 Standard Electrical Ratings PA, PB, PC 1 Series 15 Amp Res., 125 VAC 10 Amp Res., 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC PG 1 Series 15 Amp Res., 125 VAC 10 Amp Res., 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1 SPDT NO C NC ^% PC and PG Series not UL listed or CSA approved, PC Series rated 10 Amp Res., 125/250 VAC; 1/3 HP 125/250 VAC. Standard Temperature Ratings Ambient: -4°F (-20°C) to 122°F (50°C) Fluid: See specification table on page 26 for rated overrange temperature. Operation Temperature sensed by the bulb creates an internal pressure within the transducer. This pressure is then converted into movement of the piston. This piston movement is then used to control the operation of the electrical snap-action switch in the switch unit. Options (See pages 34-35) 123 4 Enclosures ASCO TRI-POINT switches are available in either a general purpose or watertight enclosure, in addition to open frame construction. These enclosed units are made in accordance with NEMA and UL standards. These standards define the protection level an enclosure gives and the tests it must pass to meet a particular design. General Purpose – Type 1. These enclosures are designed for indoor use to protect personnel from accidental contact with the equipment. P-Series general purpose enclosures are painted, zinc-coated steel and have a 7/8” diameter hole at the top for electrical entry. Watertight – Type 4. Watertight and dust-tight enclosures are intended for use indoors and outdoors to protect the enclosed equipment against splashing or falling water, windblown dust and water, hose directed water, and severe external condensation. P-Series watertight switch enclosures are epoxy-painted, zinccoated steel with a 1/2” conduit hub in the side of the lower housing for electrical entry. (For optional 316 SS watertight enclosure see page 29.) Dimensions (inches) P-Series Temperature (Mounting brackets optional) Open Frame PA and PC Switch Units with Transducer Unit Types RD-RV Open Frame PB and PG Switch Units with Transducer Unit 2.5 2.5 .233 DIA HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) 2.5 2.4 1.8 3.8 DIA. 3.8 DIA. 5.7 4.2 9.926 4.0 5.54 5.1 9.5 4.5 .4 1/2 NPT 1.8 .233 DIA HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) .4 1/2 NPT 1.8 3.8 DIA. .233 DIA HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) 3.8 DIA. 1.5 1.5 2.7 Type 1 General Purpose Switch Unit with Transducer Unit Type 4 Watertight Switch Unit with Transducer Unit 1.8 ADDITIONAL SPACING REQUIRED FOR REMOVAL OF COVER 7/8 DIA. HOLE FOR 1/2 CONDUIT CONNECTION 1.4 .8 .223 DIA. HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) 4.9 4.5 1.7 2.5 4.0 2.6 1.8 .5 .08 3.8 DIA. 3.8 DIA. 1/2 NPT CONDUIT CONNECTION 5.8 4.7 6.5 5.3 4.8 6.4 5.3 10.3 9.6 2.5 3.0 1.9 .3 1/2 NPT .4 1.8 1/2 NPT 1.8 2.04 .233 DIA HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) .233 DIA HOLES FOR MOUNTING WITH #10 (.190 DIA.) SCREWS (2 PLACES) 3.8 DIA. 2.0 3.8 DIA. 4.0 1.5 3.0 25 4 P-SERIES Temperature Switches 123 How to Order How to Select and Order ASCO P-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. 2. 3. 4. Select the adjustable operating range based on desired actuation temperature. Check that rated overrange temperature is sufficient. Read across and select the desired P-Series switch unit with the proper enclosure. Continue across and select a matching transducer unit. Select P-Series temperature switch PA Switch Unit General Purpose Enclosure Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PA16A/KA10A1. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one PA16A and one KA10A1. Options – Add appropriate suffix for desired option or accessory (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., PA 1 6A and KA 1 0A1. PA, PB, or PC unit below PB Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . PC Switch Unit Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and nonadjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. Watertight Enclosure Open Frame Open Frame Specifications Adjustable Deadband Maximum Full Scale Adjustable Operating Capillary Range Direct (°F) Mount Copper SS -30 - 60 0 - 90 50 - 160 100 - 220 160 - 260 225 - 340 300 - 450 350 - 510 250 260 260 260 260 ------- 250 300 350 400 500 550 550 550 10 10 10 10 10 10 12 12 26 Fixed Deadband Open Frame 1 Transducer Unit The temperature transducer works on the vapor principle where the internal pressure within the system is generated by the vapor pressure of a chemical within a sealed system. The temperature sensed by the bulb is related uniquely to an internal pressure within the system. The pressure acts on a diaphragm/piston to create the force output from the transducer into the switch unit. Temperature transducers are available in two constructions. The direct mount (local) unit includes a 1/2” NPT connection for direct application to the process. The capillary and bulb-type construction allows for remote mounting from the process. Two-Stage Fixed Deadband PA16A PA16A PA16A PA16A PA16A PA16A PA16A PA16A Open Frame General Purpose Watertight Enclosure Catalog No. Fixed Deadband At Mid-Range (°F) 1 Catalog No. Catalog No. Catalog No. PA11B PA11B PA11B PA11B PA11B PA11B PA11B PA11B 4 4 4 4 4 4 5 5 PB16A PB16A PB16A PB16A PB16A PB16A PB16A PB16A PB10A PB10A PB10A PB10A PB10A PB10A PB10A PB10A PB11B PB11B PB11B PB11B PB11B PB11B PB11B PB11B General Purpose Watertight Enclosure Catalog No. PA10A PA10A PA10A PA10A PA10A PA10A PA10A PA10A All switch units above are in stock for immediate delivery. °C = (°F -32) x 5/9 Capillary and Bulb Temperature Transducer Units Separation Minimum At Mid-Range Catalog (°F) 1 No. 250 300 350 450 500 600 700 800 Direct Mount 1/2” NPT Open Frame Adjustable Deadband Rated Overrange Temperature (°F) Select transducer unit below Values shown are nominal. Fixed Deadband At Mid-Range (°F) 7 7 7 7 7 7 9 9 Maximum Full Scale Direct Mount 6’ Capillary and Bulb 12’ Capillary and Bulb General Purpose Watertight Enclosure Minimum At Mid-Range (°F) Open Frame Copper 316 SS Copper 316 SS Copper 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 9 9 11 12 10 12 15 16 PC16A PC16A PC16A PC16A PC16A PC16A PC16A PC16A PC10A PC10A PC10A PC10A PC10A PC10A PC10A PC10A PC11B PC11B PC11B PC11B PC11B PC11B PC11B PC11B KB10A1 KD10A1 KF10A1 KJ10A1 KL10A1 ------- KB10A4 KD10A4 KF10A4 KJ10A4 KL10A4 ------- KB11A1 KD11A1 KF11A1 KJ11A1 KL11A1 KN11A1 KT11A1 KU11A1 KB11A4 KB11A1D KB11A4D KD11A4 KD11A1D KD11A4D KF11A4 KF11A1D KF11A4D KJ11A4 KJ11A1D KJ11A4D KL11A4 KL11A1D KL11A4D KN11A4 KN11A1D KN11A4D KT11A4 KT11A1D KT11A4D KU11A4 KU11A1D KU11A4D All switch units and transducer units above are in stock for immediate delivery. 27 4 P-SERIES Temperature Switches 123 How to Order How to Select and Order ASCO P-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. 2. 3. 4. Select the adjustable operating range based on desired actuation temperature. Check that rated overrange temperature is sufficient. Read across and select the desired P-Series switch unit with the proper enclosure. Continue across and select a matching transducer unit. Select P-Series temperature switch PA Switch Unit General Purpose Enclosure Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PA16A/KA10A1. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one PA16A and one KA10A1. Options – Add appropriate suffix for desired option or accessory (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., PA 1 6A and KA 1 0A1. PA, PB, or PC unit below PB Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . PC Switch Unit Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and nonadjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. Watertight Enclosure Open Frame Open Frame Specifications Adjustable Deadband Maximum Full Scale Adjustable Operating Capillary Range Direct (°F) Mount Copper SS -30 - 60 0 - 90 50 - 160 100 - 220 160 - 260 225 - 340 300 - 450 350 - 510 250 260 260 260 260 ------- 250 300 350 400 500 550 550 550 10 10 10 10 10 10 12 12 26 Fixed Deadband Open Frame 1 Transducer Unit The temperature transducer works on the vapor principle where the internal pressure within the system is generated by the vapor pressure of a chemical within a sealed system. The temperature sensed by the bulb is related uniquely to an internal pressure within the system. The pressure acts on a diaphragm/piston to create the force output from the transducer into the switch unit. Temperature transducers are available in two constructions. The direct mount (local) unit includes a 1/2” NPT connection for direct application to the process. The capillary and bulb-type construction allows for remote mounting from the process. Two-Stage Fixed Deadband PA16A PA16A PA16A PA16A PA16A PA16A PA16A PA16A Open Frame General Purpose Watertight Enclosure Catalog No. Fixed Deadband At Mid-Range (°F) 1 Catalog No. Catalog No. Catalog No. PA11B PA11B PA11B PA11B PA11B PA11B PA11B PA11B 4 4 4 4 4 4 5 5 PB16A PB16A PB16A PB16A PB16A PB16A PB16A PB16A PB10A PB10A PB10A PB10A PB10A PB10A PB10A PB10A PB11B PB11B PB11B PB11B PB11B PB11B PB11B PB11B General Purpose Watertight Enclosure Catalog No. PA10A PA10A PA10A PA10A PA10A PA10A PA10A PA10A All switch units above are in stock for immediate delivery. °C = (°F -32) x 5/9 Capillary and Bulb Temperature Transducer Units Separation Minimum At Mid-Range Catalog (°F) 1 No. 250 300 350 450 500 600 700 800 Direct Mount 1/2” NPT Open Frame Adjustable Deadband Rated Overrange Temperature (°F) Select transducer unit below Values shown are nominal. Fixed Deadband At Mid-Range (°F) 7 7 7 7 7 7 9 9 Maximum Full Scale Direct Mount 6’ Capillary and Bulb 12’ Capillary and Bulb General Purpose Watertight Enclosure Minimum At Mid-Range (°F) Open Frame Copper 316 SS Copper 316 SS Copper 316 SS Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 9 9 11 12 10 12 15 16 PC16A PC16A PC16A PC16A PC16A PC16A PC16A PC16A PC10A PC10A PC10A PC10A PC10A PC10A PC10A PC10A PC11B PC11B PC11B PC11B PC11B PC11B PC11B PC11B KB10A1 KD10A1 KF10A1 KJ10A1 KL10A1 ------- KB10A4 KD10A4 KF10A4 KJ10A4 KL10A4 ------- KB11A1 KD11A1 KF11A1 KJ11A1 KL11A1 KN11A1 KT11A1 KU11A1 KB11A4 KB11A1D KB11A4D KD11A4 KD11A1D KD11A4D KF11A4 KF11A1D KF11A4D KJ11A4 KJ11A1D KJ11A4D KL11A4 KL11A1D KL11A4D KN11A4 KN11A1D KN11A4D KT11A4 KT11A1D KT11A4D KU11A4 KU11A1D KU11A4D All switch units and transducer units above are in stock for immediate delivery. 27 P-SERIES Temperature Switches How to Select and Order ASCO P-Series switches consist of two components, the switch unit and the transducer unit. How to Select How to Order 1. Select the adjustable operating range based on desired actuation temperature. 2. Check that rated overrange temperature is sufficient. 3. Read across and select the desired P-Series switch unit with the proper enclosure. 4. Continue across and select a matching transducer unit. Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PG16A/KA10A1. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one PG16A and one KA10A1. Options – Add appropriate suffix for desired option (see pages 34-35). Important Note: The third digit of each of the catalog numbers must be identical, e.g., PG 1 6A and KA 1 0A1. Select P-Series switch unit and transducer unit below PG Switch Unit Transducer Unit Limited Adjustable Deadband units have an adjustable set point and use a special snapaction switch that varies the deadband within the limits listed below. The temperature transducer works on the vapor principle where the internal pressure within the system is generated by the vapor pressure of a chemical within a sealed system. The temperature sensed by the bulb is related uniquely to an internal pressure within the system. The pressure acts on a diaphragm/piston to create the force output from the transducer into the switch unit. Open Frame Specifications Limited Adjustable Deadband Maximum Full Scale Adjustable Capillary Operating Range Direct (°F) Mount Copper SS Direct Mount Open Frame General Purpose Watertight Enclosure Minimum At Mid-Range (°F) 1 Catalog No. Catalog No. Catalog No. Capillary and Bulb Temperature Transducer Units Adjustable Deadband Rated Overrange Temperature (°F) 6’ Capillary and Bulb Copper 316 SS Copper 316 SS 12’ Capillary and Bulb Copper 316 SS Catalog Catalog Catalog Catalog Catalog No. No. No. No. No. Catalog No. -30 - 60 250 250 250 6 - 12 PG16A PG10A PG11B KB10A1 KB10A4 KB11A1 KB11A4 KB11A1D KB11A4D 0 - 90 260 300 300 6 - 12 PG16A PG10A PG11B KD10A1 KD10A4 KD11A1 KD11A4 KD11A1D KD11A4D KF10A1 KF10A4 KF11A1 KF11A4 KF11A1D KF11A4D 50 - 160 260 350 350 6 - 12 PG16A PG10A PG11B 100 - 220 260 400 450 6 - 12 PG16A PG10A PG11B KJ10A1 KJ10A4 KJ11A1 KJ11A4 KJ11A1D KJ11A4D 160 - 260 260 500 500 6 - 12 PG16A PG10A PG11B KL10A1 KL10A4 KL11A1 KL11A4 KL11A1D KL11A4D 225 - 340 --- 550 600 6 - 12 PG16A PG10A PG11B --- --- 300 - 450 --- 550 700 6 - 12 PG16A PG10A PG11B --- --- KT11A1 KT11A4 KT11A1D KT11A4D 350 - 510 --- 550 800 6 - 12 PG16A PG10A PG11B --- --- KU11A1 KU11A4 KU11A1D KU11A4D KN11A1 KN11A4 KN11A1D KN11A4D All switch units and transducer units above are in stock for immediate delivery. °C = (°F -32) x 5/9 28 Direct Mount 1/2” NPT 1 Values shown are nominal. 123 4 Switches with Optional 316 Stainless Steel Enclosure Every ASCO P-Series temperature switch is available in a corrosion-resistant, stainless steel enclosure. Typical applications include: • Offshore platforms • Hydrocarbon processing plants • Oil & gas fields • Oil & gas transmission lines • Chemical plants • Breweries • Paper pulp mills • Salt spray locations Stainless Steel Enclosure ASCO Type 4X watertight enclosure is designed to provide protection against windblown dust, rain, sleet or external ice formation. The switch and transducer unit are available only as factory-assembled units. How to Select and Order ASCO P-Series switches with 316 SS enclosure consist of two factory-assembled components, the switch unit and the transducer unit. How to Select (use tables on pages 26-28) 1. Select the adjustable operating range based on desired actuation temperature. 2. Check that rated overrange temperature is sufficient. 3. Read across and select the desired P-Series switch unit with open frame construction. 4. To add a 316 SS enclosure, change the fourth digit of the open frame catalog number from “6” to “5”, e.g., PG1 6 A becomes PG5 5 A. 5. Continue across and select a matching direct mount or capillary and bulb transducer unit compatible with the fluid. For direct mount unit add suffix “D” to switch catalog number, e.g., PG15A becomes PG15AD; for capillary and bulb unit add suffix “C”, e.g., PG15A becomes PG15AC. How to Order Factory assembled only – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., PG15AD/KA10A4 for direct mount and PG15AC/KA11A4 for capillary and bulb unit. Options – Add appropriate suffix for desired option (see pages 34-35). Dimensions (inches) P-Series Temperature with Optional 316 SS Enclosure 4.9 4.5 4.9 4.5 1/2 NPT CONDUIT CONNECTION 1/2 NPT CONDUIT CONNECTION 3/8 DIA. 6.9 5.6 WRENCH TIGHT DIMS. FOR 1/2 PIPE THREADS 2.3 .27 DIA 2 HOLES FOR MOUNTING* 1.7 .27 DIA. 2 HOLES FOR MOUNTING* 1.7 9.54 1.8 1.8 1/2 NPT 3/8 DIA. 4.0 *MOUNTING BRACKET OPTIONAL 5.35 1/2 NPT CONDUIT CONNECTION 1.7 .4 2.3 4.3 29 S-SERIES Temperature Switches Switches for -60 through 640°F with Adjustable Set Points, Fixed or Adjustable Deadband and General Purpose, Watertight or Explosion-Proof Enclosures Features: • Set point repeatability, +1°F (1/2°C). • All wiring terminals, adjustments and visual scales are accessible from the front of the switch. • Choice of general purpose, watertight or explosion-proof enclosures. • Choice of fixed or full-range adjustable deadband. • Choice of single or two-stage units. • Manual reset units available. • Mounts in any position. • Rugged and vibration resistant. • Visual adjustment scales in °F and °C. • External adjusting nuts. • Separate temperature, electrical and adjusting chambers. • Direct mount (local) or capillary and bulb (remote) sensors. • Temperature transducers available with copper or 316 stainless steel wetted material. • Withstands high overrange temperatures. • Mix and match switch and transducer components for increased stock flexibility or to change pressure ranges in field. General Description: ASCO S-Series temperature switches consist of a switch unit and a transducer unit. They can be ordered separately for customer stocking and/or field assembly or as a complete factory-assembled unit. Switch S-Series temperature switch units incorporate the unique ASCO TRI-POINT alternating fulcrum balance plate to control the operation of one or more electrical snap-action swtiches. The electrical snap-action switch together with the adjusting mechanism is a fully-tested, self-contained subassembly. Standard Electrical Ratings SA, SB, SC, SD and SE Series 15 Amp Res., 125 VAC 10 Amp Res., 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp Res., 125 VDC 1/4 Amp Res., 250 VDC ^% SPDT NO C NC Standard Temperature Ratings Ambient: -4°F (-20°C) to 140°F (60°C) Fluid: See specification table on page 32 for rated overrange temperature. from the process. The transducer unit (like the switch unit) is a fully-tested, self-contained subassembly. Transducer The temperature transducer unit uses a vapor pressure principle where the internal pressure within the unit is generated by the vapor pressure of a chemical within a sealed system. Temperature transducers are available in two constructions, a direct mount or capillary and bulb construction. The direct mount unit includes a 1/2” NPT connection for direct mounting to the process. The capillary and bulb construction allows remote mounting 30 Operation Temperature sensed by the bulb creates an internal pressure within the transducer. This pressure is then converted into movement of the piston. This piston movement is then used to control the operation of the electrical snap-action switch in the switch unit. Options (See pages 34-35) 4 123 Enclosures ASCO TRI-POINT S-Series switches are available in three standard enclosures. All of these enclosed units are made in accordance with NEMA and UL standards. General Purpose – Type 1. These enclosures are designed for indoor use to protect personnel from accidental contact with the equipment. S-Series general purpose switch units consist of a copper-free* aluminum die-cast body with a formed copper-free* aluminum cover; two 3/4” conduit hubs with one plug are provided. Watertight – Type 4. Watertight and dust-tight enclosures are intended for use indoors and outdoors to protect the enclosed equipment against splashing or falling water, windblown dust and water, hose directed water, and severe external condensation. S-Series watertight switch units have a copper-free* aluminum die-cast body and a formed copper-free* aluminum cover with Buna “N” gaskets; two 3/4” conduit hubs with one plug are provided. Class I locations are those in which flammable gases are or may be present in the air in sufficient quantities to produce explosive or ignitable mixtures. Class I locations are classified by group letter, which defines particular atmospheres. Division 1 locations are areas where the hazardous concentration exists continuously, intermittently or periodically under normal operating conditions. Division 2 locations are those where the hazardous vapors are present only in case of accidental rupture or breakdown of equipment. ASCO TRI-POINT explosion-proof enclosures with letter B, C or D in the fifth position are listed for Class I, Groups B, C, and D, Division 1. They are also suitable for the less stringent Division 2 environment. Class II locations are those which are hazardous because of the presence of combustible dust. All ASCO TRI-POINT explosion-proof enclosures are listed for Groups E, F, and G locations. The switch body and cover are die-cast copper-free* Explosion-Proof – Types 7 and 9. Type 7 enclosures aluminum with a Buna “N” gasket. Two 3/4” conduit are intended for use in locations defined by the National hubs with one plug are provided. Electrical Code as Class I. Type 9 enclosures are intended for Class II locations. Dimensions (inches) S-SeriesTemperature With Direct Mount Transducer With Capillary and Bulb Transducer ADDITIONAL SPACE REQUIRED FOR REMOVAL OF COVER 3.5 4.1 1.03 2.3 1.6 3/4 NPT FOR CONDUIT CONN. BOTH ENDS 11.6 11/32 DIA. FOR MOUNTING (2PLACES) 1.0 3.8 DIA. 8.9 2.2 4.0 1/2 NPT 3.2 3.8 * Less than 0.6% copper. 31 4 S-SERIES Temperature Switches 123 Select transducer unit below How to Select and Order ASCO S-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. 2. 3. 4. Select the adjustable operating range based on desired actuation temperature. Check that rated overrange temperature is sufficient. Read across and select the desired S-Series switch unit with the proper enclosure. Continue across and select a matching transducer unit compatible with the fluid. How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., SA10D/QA10A1. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one SA10D and one QA10A1. Options – Add appropriate suffix for desired option (see pages 34-35). Select S-Series temperature switch SA Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . Important Note: The third digit of each of the catalog numbers must be identical, e.g., SA 1 0D and QA 1 0A1. SA, SB, SC, SD or SE unit below SB, SD or SE Switch Unit SC Switch Unit SB Switch Unit: Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. SD Switch Unit: Manual reset on decreasing temperature units operate automatically on increasing temperature and must be reset manually on decreasing temperature. (To order, change second digit to letter “D”, e.g., S B 40D becomes S D 40D). SE Switch Unit: Manual reset on increasing temperature units operate automatically on decreasing temperature and must be reset manually on increasing temperature. (To order, change second digit to letter “E”, e.g., S B 40D becomes S E 40D). Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. General Purpose Specifications Adjustable Deadband Maximum Full Scale Adjustable Operating Capillary Range Direct (°F) Mount Copper SS -30 - 60 0 - 90 50 - 160 100 - 220 160 - 260 225 - 340 300 - 450 350 - 510 425 - 640 250 260 260 260 260 --------- 250 300 350 450 500 550 550 550 550 Minimum At Mid-Range Catalog (°F) 1 No. Catalog No. Catalog No. SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D 3 3 3 3 3 6 6 7 20 Catalog No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (°F) 1 SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D 4 4 4 4 4 8 8 10 27 General Watertight ExplosionPurpose Enclosure Proof All switch units above are in stock for immediate delivery. 1 Values shown are nominal. Transducer Unit The temperature transducer works on the vapor principle where the internal pressure within the system is generated by the vapor pressure of a chemical within a sealed system. The temperature sensed by the bulb is related uniquely to an internal pressure within the system. The pressure acts on a diaphragm/piston to create the force output from the transducer into the switch unit. Temperature transducers are available in two constructions. The direct mount (local) unit includes a 1/2” NPT connection for direct application to the process. The capillary and bulb-type construction allows for remote mounting from the process. Two-Stage Fixed Deadband Transducer Units Separation Fixed Deadband At Mid-Range (°F) 1 8 8 8 8 9 12 12 18 32 250 300 350 450 500 600 700 800 890 °C = (°F -32) x 5/9 32 Fixed Deadband or Manual Reset General Watertight ExplosionPurpose Enclosure Proof Capillary and Bulb Explosion Proof Adjustable Deadband Rated Overrange Temperature (°F) Direct Mount 1/2” NPT Maximum Full Scale Direct Mount General Purpose Catalog No. Catalog No. 8 8 8 8 9 12 12 18 32 SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D 12’ Capillary and Bulb 316 SS (Plain Capillary) Copper (Armored Capillary) 316 SS & (Plain Capillary) Copper 316 SS Copper (Armored Capillary) Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D QB10A1 QD10A1 QF10A1 QJ10A1 QL10A1 --------- QB10A4 QD10A4 QF10A4 QJ10A4 QL10A4 --------- QB11A1 QD11A1 QF11A1 QJ11A1 QL11A1 QN11A1 QT11A1 QU11A1 --- QB11A4 QD11A4 QF11A4 QJ11A4 QL11A4 QN11A4 QT11A4 QU11A4 QW11A4 QB11A1D QD11A1D QF11A1D QJ11A1D QL11A1D QN11A1D QT11A1D QU11A1D --- QB11A4D QD11A4D QF11A4D QJ11A4D QL11A4D QN11A4D QT11A4D QU11A4D QW11A4D Watertight ExplosionEnclosure Proof Minimum At Mid-Range (°F) 1 6’ Capillary and Bulb All switch units and transducer units above are in stock for immediate delivery. 33 4 S-SERIES Temperature Switches 123 Select transducer unit below How to Select and Order ASCO S-Series switches consist of two components, the switch unit and the transducer unit. How to Select 1. 2. 3. 4. Select the adjustable operating range based on desired actuation temperature. Check that rated overrange temperature is sufficient. Read across and select the desired S-Series switch unit with the proper enclosure. Continue across and select a matching transducer unit compatible with the fluid. How to Order Factory assembled – Simply order the switch and transducer unit by catalog number joined by a slash (/), e.g., SA10D/QA10A1. Field assembled – Simply order the switch and transducer units separately by individual catalog number, e.g., one SA10D and one QA10A1. Options – Add appropriate suffix for desired option (see pages 34-35). Select S-Series temperature switch SA Switch Unit Single-Stage Adjustable Deadband units allow independent adjustment of the set and reset points over the full operating range of the switch. The minimum difference between set and reset points is the deadband listed below; the maximum difference is the full range of the switch . Important Note: The third digit of each of the catalog numbers must be identical, e.g., SA 1 0D and QA 1 0A1. SA, SB, SC, SD or SE unit below SB, SD or SE Switch Unit SC Switch Unit SB Switch Unit: Single-Stage Fixed Deadband units have an adjustable set point and a non-adjustable automatic reset point. SD Switch Unit: Manual reset on decreasing temperature units operate automatically on increasing temperature and must be reset manually on decreasing temperature. (To order, change second digit to letter “D”, e.g., S B 40D becomes S D 40D). SE Switch Unit: Manual reset on increasing temperature units operate automatically on decreasing temperature and must be reset manually on increasing temperature. (To order, change second digit to letter “E”, e.g., S B 40D becomes S E 40D). Two-Stage Fixed Deadband units consist of two separate snap-action switches, each with an independently adjustable set point and non-adjustable reset point. The difference between the set and reset points of each switch is the deadband listed below; the minimum difference between the set points of the two switches is the separation. General Purpose Specifications Adjustable Deadband Maximum Full Scale Adjustable Operating Capillary Range Direct (°F) Mount Copper SS -30 - 60 0 - 90 50 - 160 100 - 220 160 - 260 225 - 340 300 - 450 350 - 510 425 - 640 250 260 260 260 260 --------- 250 300 350 450 500 550 550 550 550 Minimum At Mid-Range Catalog (°F) 1 No. Catalog No. Catalog No. SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA10D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA11D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D SA12D 3 3 3 3 3 6 6 7 20 Catalog No. Catalog No. Catalog No. Fixed Deadband At Mid-Range (°F) 1 SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB10D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB11D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D SB12D 4 4 4 4 4 8 8 10 27 General Watertight ExplosionPurpose Enclosure Proof All switch units above are in stock for immediate delivery. 1 Values shown are nominal. Transducer Unit The temperature transducer works on the vapor principle where the internal pressure within the system is generated by the vapor pressure of a chemical within a sealed system. The temperature sensed by the bulb is related uniquely to an internal pressure within the system. The pressure acts on a diaphragm/piston to create the force output from the transducer into the switch unit. Temperature transducers are available in two constructions. The direct mount (local) unit includes a 1/2” NPT connection for direct application to the process. The capillary and bulb-type construction allows for remote mounting from the process. Two-Stage Fixed Deadband Transducer Units Separation Fixed Deadband At Mid-Range (°F) 1 8 8 8 8 9 12 12 18 32 250 300 350 450 500 600 700 800 890 °C = (°F -32) x 5/9 32 Fixed Deadband or Manual Reset General Watertight ExplosionPurpose Enclosure Proof Capillary and Bulb Explosion Proof Adjustable Deadband Rated Overrange Temperature (°F) Direct Mount 1/2” NPT Maximum Full Scale Direct Mount General Purpose Catalog No. Catalog No. 8 8 8 8 9 12 12 18 32 SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC10D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D SC11D 12’ Capillary and Bulb 316 SS (Plain Capillary) Copper (Armored Capillary) 316 SS & (Plain Capillary) Copper 316 SS Copper (Armored Capillary) Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D SC12D QB10A1 QD10A1 QF10A1 QJ10A1 QL10A1 --------- QB10A4 QD10A4 QF10A4 QJ10A4 QL10A4 --------- QB11A1 QD11A1 QF11A1 QJ11A1 QL11A1 QN11A1 QT11A1 QU11A1 --- QB11A4 QD11A4 QF11A4 QJ11A4 QL11A4 QN11A4 QT11A4 QU11A4 QW11A4 QB11A1D QD11A1D QF11A1D QJ11A1D QL11A1D QN11A1D QT11A1D QU11A1D --- QB11A4D QD11A4D QF11A4D QJ11A4D QL11A4D QN11A4D QT11A4D QU11A4D QW11A4D Watertight ExplosionEnclosure Proof Minimum At Mid-Range (°F) 1 6’ Capillary and Bulb All switch units and transducer units above are in stock for immediate delivery. 33 OPTIONS Pressure/Temperature Switches H-Series, P-Series and S-Series Snap-Action Switch Options P-Series Switch Options Optional snap-action switches to meet specific electrical loads or application conditions are available on most ASCO TRI-POINT switch units. Generally, the construction of a switch unit with optional snap-action switches contains other specific parts and may be ordered only as a factory-built unit. To specify a particular optional construction, add the appropriate suffix to the switch unit catalog number, e.g., SA10D with optional gold contact snapaction switch (suffix “P”) would become SA10D P . Panel Mount – Open frame P-Series compact switch units are Description DC Rating 1 Amp Double Break 5 Amp, 125, 250 VAC 1/4 HP, 125 VAC 1/2 HP, 250 VAC 1 Amp, 125 VDC 1/2 Amp, 250 VDC DC Rating 10 Amps, SPDT 10 Amp, 125 VAC, VDC 1/8 HP, 125 VAC, VDC Double-pole Double-throw (Two SPDT Switches with Common Lever) Gold Contact Dry Circuit SPDT 5 Amp, 125, 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp, 125 VDC 1/4 Amp, 250 VDC 1 Amp, 28 VAC 1 Amp, 28 VDC 25 Amp Res, 28 VDC 10 Amp Ind, 28 VDC 5 Amp Motor, 28 VDC 3 Amp Lamp, 28 VDC 1 Amp, 125 VAC 5 Amp, 125, 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp, 125 VDC 1/4 Amp, 250 VDC 20 Amp, 125, 250 VAC 1 HP, 125 VAC 2 HP, 250 VAC 1/2 Amp, 125 VDC 1/4 Amp, 250 VDC 5 Amp, 125, 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp, 125 VDC 1/4 Amp, 250 VDC 5 Amp, 125, 250 VAC 1/8 HP, 125 VAC 1/4 HP, 250 VAC 1/2 Amp, 125 VDC Hermetically Sealed SPDT High Ambient 250°F SPDT High Power 1 HP SPDT Moisture Resistant Sealed Switch SPDT Tight Fixed Deadband SPDT 34 Electrical Rating Catalog Suffix G M K P H available for panel mounting with the switch unit inside and the transducer outside. The panel separates the fluid sensing portion from the electromechanical portion. Five holes for bolts and operating stem must be drilled or punched through the panel. Three constructions are available: add the suffix listed below to the switch unit catalog number for the desired thickness. Deadband Variation From Listing SA: +50% SB, SC, PA: +100% H: +200% PB: +400% SA: +50% SB, SC, PA: +100% H: +120% PB: +400% SA, SB, SD, SE, PB: +50% SA, SB, SC, PA: +25% H: +50% PB, PC: +100% SA, PA: +100% H: +200% PB: +600% F SA, SB, SC: +25% W SA: +50% SB, SC: +100% PB: +400% J SA: None SB, SC, PA: +25% PB, H: +50% T SB, SC: -50% Panel Thickness Suffix 10 Ga (.135+.005) 14 Ga (.075+.005) 16 Ga (.060+.005) 10 11 12 S-Series Switch Options Industrial Adjusting Nut Covers – Available in clear plastic or metal to prevent tampering with set point adjusting nuts. Clear plastic cover: To order, add suffix “1” to the switch unit catalog number, or order separately as SP01. Metal cover: To order, add suffix “2” to the switch unit catalog number, or order separately as SP02. JIC Construction – A switch unit having the electrical and adjusting nut covers attached to the switch body by a chain. Also designed to Type 13 specifications. To order, add suffix “3” to the switch unit catalog number, or order separately as SP03. Terminal Block – Applicable to switch units with one single-poledouble-throw switch. The terminal strip is prewired to the snap-action switch. To order, add suffix “4” to the switch unit catalog number, or order separately as SP04. Factory Sealed – Explosion-proof units may be ordered with a factory seal separating the electrical chamber from the conduit hubs and 24” long #14 AWG 105°C. rated lead wires. To order, change the fourth digit of the switch unit catalog number from “2” to “3”, e.g., SA1 2 D becomes SA1 3 D. 4 123 Pressure Transducer Options Special Wetted Materials – The following diaphragms may be substituted on transducer body materials of aluminum, brass, polyester and stainless steel. To order, substitute the material code below in the seventh digit of the transducer catalog number, e.g., a TF10A1 1 with optional FKM diaphragm becomes a TF10A1 2 . Material Code Diaphragm Buna “N” Ethylene Propylene Neoprene Fluorosilicone FKM 1 6 3 7 2 Pressure Snubbers – A pressure snubber (1/4” NPTF by 1/4” NPTM) installed in the transducer pressure connection will dampen the pressure spikes to a value which will not cause damage. It consists of a body with a porous metal disc of stainless steel through which the fluid passes. To order, select a snubber compatible with the fluid. Available by seperate catalog number only (see table below). Temperature Range -4°F (-20°C) to 180°F (82°C) -4°F (-20°C) to 250°F (121°C) -4°F (-20°C) to 180°F (82°C) -40°F (-40°C) to 250°F (121°C) -4°F (-20°C) to 250°F (121°C) Oxygen Cleaning – Pressure transducers for oxygen service should be specially cleaned. They are degreased and blacklight inspected, then assembled in a clean area and tested with oil-free air or nitrogen. Use metal body transducer with FKM or neoprene diaphragm and add suffix “H” to transducer catalog number, e.g., TA40A13 becomes TA40A13 H . Brass 303 SS Catalog No. Catalog No. Fluid Air, Non-Hazardous Gases Water, Light Oil (under 225 SSU) Oil (Heavy, (over 225 SSU) Pressure Rating (psig) TP04G2 TP04E2 TP04D2 2000 TP04G3 TP04E3 TP04D3 5000 Process Connection – A female process connection (1/4” NPT) is standard on all pressure transducers. A 1/2” NPT is available as an option on gauge pressure transducers. To order, add suffix “B” to transducer catalog number, e.g., RF10A21 becomes RF10A21 B . Note: Not available on nylon transducers. P-Series and S-Series Temperature Transducer Options Armored Capillaries – Double braided copper armor is standard for copper capillary units. Stainless steel spiral interlocked armor is available for stainless steel capillary units. Add suffix “C” to transducer catalog number. Thermal Well Thermal Well 1 – Use with direct or remote sensors for protecting sensing bulb. This allows removal of bulb while maintaining a pressure-tight vessel. Available in 1/2” NPT or 3/4” NPT process connection in brass or 316 SS. Dimensions are in accordance with SAMA Std. RC17-9. Standard “U” dimension (insertion length) is 2-1/2” for direct mount and 6’ capillary units and is 4-1/2” for 12’ capillary units. Material Brass 316 SS 1 Pressure Rating (psig) 1000 6000 Process Connection “U” 1/2” NPT 3/4” NPT Dimensions (Inches) Catalog No. Catalog No. 2-1/2 4-1/2 7-1/2 10-1/2 2-1/2 4-1/2 7-1/2 10-1/2 QP03 QP13 QP23 QP33 QP07 QP17 QP27 QP37 QP04 QP14 QP24 QP34 QP08 QP18 QP28 QP38 Longer Capillaries – Standard copper and stainless steel capillary units can be furnished in 12’ lengths. To order, add suffix “D” to transducer catalog number. Consult ASCO for longer length capillaries. Capillary Length (Feet) Transducer Suffix 6 12 13 - 20 21 - 50 51 - 80 --D E F G Bulb Length (Inches) 3-1/2 5-1/2 5-1/2 8-1/2 11-1/2 “U” Dimension Required (Inches) 2-1/2 4-1/2 4-1/2 7-1/2 10-1/2 Union Connector – For use with remote units for mounting of bulb in fluid being controlled. Available in 1/2” NPT and 3/4” NPT process connections in brass or 316 SS. Process Connection 1/2” NPT 3/4” NPT Material Pressure Rating (psig) Catalog No. Catalog No. Brass 316 SS 500 1500 QP01 QP05 QP02 --- Jam nuts provided with thermal wells. 35 Definitions and Fluid Compatibility Guide Definitions Accuracy – The maximum deviation from the set point under specified operating condition (ambient temperature, barometric pressure, etc.). Adjustable Deadband – Refers to the capability of a pressure or temperature switch to allow the deadband to be adjusted over a given range. Certain ASCO TRI-POINT switches have an adjustable deadband which can be adjusted over the total operating range of the switch. Adjustable Operating Range – The pressure or temperature range of the switch within which the set point may be adjusted. Differential Pressure – The difference between two pressures. A differential pressure switch senses two pressure sources and can be adjusted to actuate on a desired difference between them. Guage Pressure – The actual reading of a typical pressure guage and is the difference between the pressure within a vessel and the atmospheric pressure surrounding it. It is normally measured in pounds per square inch (psig). Manual Reset – The switch is a semi-automatic device which operates automatically with a signal change in one direction but must be manually reset once the signal returns to its original position. Proof Pressure – A pressure which a device can be subjected to for extended periods of time without changes in its operating characteristics. Rated Overrange Temperature – A temperature which a device can be subjected to for extended periods of time without changes in its operating characteristics. Repeatability – The closeness of agreement among a number of consecutive measurements of the output for the same value of input under the same operating conditions approaching from the same direction. Repeatability is normally specified as a percentage of the upper limit of the operating range. Example: Operating range 5-100 psig with +1% repeatability; equals +1% of 100 psig or +1 psig. Reset Point – After a pressure or temperature switch has reached its set point and operated the electrical switch, it must return to a point called the reset point before the electrical switch can return to its original position. Set Point – The pressure reading at which the electrical switch element changes contact position (it can be specified either increasing or decreasing). 36 Switch Unit – ASCO uses the term “switch unit” to describe the electromechanical portion of a pressure or temperature switch. This is used in conjunction with a transducer unit to form a complete pressure or temperature switch. Transducer Unit – ASCO uses the term “transducer unit” to describe that portion of a pressure or temperature switch to which a pressure or temperature is applied which converts the input signal to another form of energy to operate the switch unit. Two-Stage (Dual) – ASCO uses the term “two stage” to describe a pressure or temperature switch which is equivalent to two pressure or temperature switches which are independently adjustable. This switch is equivalent to two fixed deadband switches. Deadbands – The deadband is the difference between the set point and reset point readings. Deadbands are listed in the specification tables at nominal values. They are representative of the deadbands of the units at the middle of the range. The deadband values for the full range adjustable deadband switches and limited adjustable deadband switches indicate the values through which the deadband may be adjusted. Generally, as the set point is adjusted through the operating range, the deadband will vary. Normally, it will become narrower as the set point is towards the bottom of the range, and will become wider when the set point is towards the top of the range. The graph shown below indicates representative trends of this type of deadband variation. Deadbands 1.5 x Catalog Value Catalog Value Half Catalog Value Bottom Mid Top Position of Set Point in Range Temperature switch deadbands are a result of the characteristics of the vapor pressure curve as well as other factors. Normally, this results in a deadband which is narrower in the top third of the range than in the bottom third of the range. The values published are nominal and representative of midrange set points. 4 123 Fluid Compatibility Guide These recommendations are to be used as a guide only, as service life of material is dependent on temperature, concentrations, or catalysts that may be added and other conditions which are beyond our control. Consult ASCO for specific service applications. Transducer Material Code of Two Digits represents process connection material and diaphragm material, respectively; these are the sixth and seventh positions of the pressure transducer catalog number. Process Connection: 6th Position Diaphragm: 7th Position Note: 1 Aluminum 2 Brass 3 303 S.S. 1 Buna “N” 2 FKM 3 Neoprene Items in black circles are standard catalog units. All others available on factory order. P - Indicates preferred construction. S - Indicates satisfactory construction. Ranges Available Material Code Vacuum Inches of Water P.S.I.G. 5 to 11 12 13 16 17 21 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No 400 400 400 400 400 3500 22 Yes No 3500 23 Yes No 3500 26 Yes No 3500 4 316 S.S. 7 Nylon/Brass 27 Yes No 3500 31 Yes Yes 8000 32 Yes Yes 8000 S S S S S S S P S P S S Acetic Acid Acetylene Air P P S S P S P S S S S S S S S S S S S S S S S S S S S S S S 33 Yes Yes 8000 36 Yes Yes 8000 S 4 316 S.S. 6 Ethylene Propylene 7 Fluorosilicone 37 Yes Yes 8000 42 Yes Yes 8000 S S S S S S S S S S Ammonia Argon-Welding 1 Benzene-Benzol P Butane S S Carbon Tetrachloride P Cellulube S S S Coke Oven Gas Ethyl Alcohol (denatured) Ethylene Glycol P P S S S S S S S S S S P S P S S S S P S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S Freon Solvents (“MF”, “TF”, “BF”) 4 P S S S S S S S S S S S Gas (natural and P S S manufactured) P S S P P S S P S S S S Hydrogen Jet Fuel (JP1 to JP6) Kerosene Methyl Alcohol (Methanol) Naphtha Nitrogen Oils (coolant, hydraulic, lubricating and motor) Oxygen, Gaseous P P P P S P P S S S P Propane Gas and Liquid “Pydraul” (“Monsanto”) S S S S S S P 2 Potassium Sulfate S S S S S P S S S S S P Toluene (Tolulo) Vacuum Vegetable Oil P P S P S S S S S P P S Steam Condensate Stoddard Solvent S S S S S 3 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S Water, Fresh, Boiler Feed Water (Distilled, Deionized, Water, Sea P S S S S S S S S S P S S S S S S S S S S S S P S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S P S S S S S S S S S S S S S S S S P S S S S S S S S S S S S S S S S S S S S S S S S Vinegar Demineralized) P P 4 Helium Steam S 71 No No 200 S P S Gasoline Gas, Inert P S S P S S S S S S S S P S S S Freon Refrigerants Fuel Oils and Diesel 44 No No 400 S S S S S S S S S S S S P S P P P S Notes: 1 For high purity applications use stainless steel transducers. 2 Oxygen service requires special cleaning, specify suffix “H”. 3 For steam service a condensate loop (pigtail) is required. 4 For pressure transducers for combustion service see pages 20-23. 5 Material availability refers to standard gauge pressure constructions only. 37 Desde1963 INTERRUPTORES Y Proveedor SENSORES DEIntegral PRESION Y de Soluciones para TEMPERATURA la Industria INTERRUPTORES Y SENSORES DE PRESION Y TEMPERATURA Los interruptores ASCO Tripoint, utilizan la tecnología de diafragma/pistón para un sensado preciso de presión y temperatura, garantizado un excelente tiempo de vida. Los materiales de fabricación son diversos y dependen de fluido a manejar. Los SENSORES ASCO son maquinados en una sola pieza (cuerpo y diafragma) para eliminar los problemas ocasionados por el desgaste de partes internas, garantizando así el tiempo más largo del mercado. Sensores ASCO 4 Sensors Stainless steel Leak proof, one piece cavity design Available for hazardous locations Broad industrial pressure range 4 Sensors ASCO, the leader in the design and manufacture of solenoid valves, now offers a complete line of Pressure Sensors. With pressure ratings up to 10,000 psig and the ability to handle difficult applications like steam and refrigeration, ASCO Pressure Sensors will meet your most demanding needs. The ASCO Pressure Sensor line is ideal for accurately measuring many process fluids in the most demanding, pulsating, and vibrating environments. The one piece pressure cavity is machined from Sensing Element • Sensor elements are bonded with inorganic material to provide low drift repeatable signal • Sensor technology provides high sensitivity permitting thicker cavities • MEM's technology • Wide operating temperature range • Ranges up to 10,000 psig • Rugged construction for harsh environments 17.4 PH stainless steel, which offers no source for contamination of the process fluid or the sensor. This design provides the stability, accuracy, flexibility, and EMI resistance that your process needs. This single, machined, pressure cavity will also allow you to handle a wide variety of applications, thus standardizing on fewer sensors, as well as reducing your inventory. No Leak Path Design • Pressure cavity is one piece (17.4 PH stainless steel) construction • Pressure sensing surface is integral to body – no separate diaphragm • Excellent isolation, over-pressure, and burst characteristics • No fill fluids utilized ASCO Pressure Sensors demonstrate ASCO's commitment to the most reliable flow control solutions. INDEX PAGE Series 40 Isolated Pressure Sensor 1 Series 42 Panel Mount Isolated Pressure Sensor 3 Series 43 Hazardous Locations Isolated Pressure Sensor 5 Series 44 Intrinsically Safe Isolated Pressure Sensor 7 Series 45 Tank Level Sensor 9 Series 46 Explosionproof Pressure Sensor 11 Series 47 High Accuracy Pressure Sensor 13 Series 50 Wet/Wet Differential Pressure Sensor 15 4 Series 40 Series Stainless Steel Media Isolated Pressure Sensor 40 Features • High strength stainless steel construction • No silicone oil, no internal o-rings, no welds • Wide operating temperature range • Ranges up to 10,000 psig • Rugged design survives harsh environments • Compatible with wide range of gases and liquids • Suitable for high shock and vibration applications Specifications Performance @ 25˚C (77˚F) Accuracy1 <±0.5% BFSL Stability (1 year) ±0.25% FS, typ. Electrical Data Proof Pressure 2X Rated Pressure Output 4-20mA 1-5VDC, 1-6VDC 0.5-4.5 V ratiometric 5X or 20,000 psig, whichever is less Excitation 10-28VDC 10-28VDC 5VDC, reg > 100 Million Output Impedance >10k Ohms <100 Ohms, nom. <100 Ohms, nom. Current Consumption 20mA, typ. <10mA <10mA Bandwith (-3dB): DC to 250 Hz DC to 1kHz DC to 1kHz Output Noise: - <2mV RMS <2mV RMS Zero Offset <±1% of FS <±1% of FS <±1% of FS Burst Pressure Pressure Cycles 1 Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability Physical Description Case 304 stainless steel Electrical Connection Refer to Ordering Information Wetted Material Refer to Ordering Information Span Tolerance <±2.0% of FS <±1.5% of FS Output Load See load line curve below Reverse Polarity Yes Protection Environmental Data Temperature Operating -40 to 85˚C (-40 to 185˚ F) Storage -40 to 100˚C (-40 to 212˚ F) Thermal Limits Compensated Range 0 to 55˚C (30 to 130˚ F) TC Zero <±1.5% of FS (<±3.0% for 0-25 psig) TC Span <±1.5% of FS Other Shock 100G, 11msec, 1/2 sine Vibration 20G Peak, 20 to 2400 Hz Rating IP-66 EMI/RFI Protection Yes <±1.5% of FS 10k Ohms, min. 10k Ohms, min. Yes No Pressure Ranges*+ Gage psig Proof psig Burst psig Pressure Range Code 0-25 50 250 00025 0-50 100 250 00050 0-100 200 500 00100 0-200 400 1,000 00200 0-500 1,000 2,500 00500 0-1,000 2,000 5,000 01000 0-2,500 5,000 12,500 02500 0-5,000 10,000 20,000 05000 0-7,500 15,000 20,000 07500 0-10,000 20,000 20,000 10000 * Typical Ranges. All ranges between 0-25 psig and 0-10,000 psig are available. Please consult factory. + Vacuum calibration available. Please consult factory. Specifications are subject to change without notice. 1 Series 40 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 40-A-00500-B-3-E-0-000 Series Type Process Connection 40 X= Special Standard A= 1/4" MNPT B= 1/8" MNPT C= 1/4" BSPP Male E= 1/2" MNPT Pressure Range Pressure Unit Outputs Electrical Interface Wetted Material XXXXX= Special X= Special X= Special X= Special X= Special XXX= Special B= BAR A= 0-50mV/V A= 2ft. cable 0= 17.4 PH 000= No options B= 20mV/V B= 4ft. cable 1= 316 L A10= ±0.10 accuracy G= 1-10V C= 6ft. cable 2= Inconel A25= ±0.25 accuracy Insert pressure range code from pressure range chart. Vacuum = V0000 F= 7/16" -20 UNF Male -14.7psig/-1.01bar H= 1/8" FNPT For vacuum replace first zero with (V) in J= 1/4" FNPT pressure code. S= 1/2" FNPT (Ex. V0500 = Vacuum to 500 psig) K= kg/cm P= psig 2 W= Inches T= 3mV/V of H2O column 1= 10mV/V 2= 0.5-4.5V ratiometric D= 10ft. cable C01 Calibration 1-9 E= Mini DIN 43650 C10 Calibration 10-49 F= Packard Metripack 150 3 pin connector C50 Calibration 50-up 3= 1-5V G= 4 pin Molex connector 4= 4-20mA H= Flex strip 3" 5= 5mV/V J= 15ft. cable 6= 1-6V K= 8ft. cable C0S Cleaned for O2 service M= Bendix military conn. R= 6 pin Bendix T= 25ft. cable Dimensional Information Table 1 Output 1-5V 4-20mA 2 Options Pin 3 Pin 2 Pin 1 +V Supply +V Supply -V Supply -V Supply Output N/C 4 Series 42 Series Panel Mount 42 Stainless Steel Media Isolated Pressure Sensor Features • High strength stainless steel construction • No silicone oil, no internal o-rings, no welds • Wide operating temperature range • Pressure ranges up to 10,000 psig • Rugged design survives harsh environments • Compatible with wide range of gases and liquids • Suitable for high shock and vibration applications • Panel up to .3" thick Specifications Performance @ 25˚C (77˚F) Accuracy1 <±0.5% BFSL Stability (1 year) ±0.25% FS, typ. Proof Pressure 2X Rated Pressure Burst Pressure 5X or 20,000 psig, whichever is less Pressure Cycles > 100 Million Electrical Data Output 4-20mA 1-5VDC, 1-6VDC 0.5-4.5 V ratiometric Excitation 10-28VDC 10-28VDC 5VDC, reg Output Impedance >10k Ohms <100 Ohms, nom. <100 Ohms, nom. Current Consumption 20mA, typ. <10mA <10mA Bandwith (-3dB): DC to 250 Hz DC to 1kHz DC to 1kHz Output Noise: - <2mV RMS <2mV RMS Physical Description Zero Offset <±1% of FS <±1% of FS <±1% of FS Case Span Tolerance <±2.0% of FS <±1.5% of FS 1 Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability 304 stainless steel See load line curve below Electrical Connection Refer to Ordering Information Output Load Wetted Material Reverse Polarity Yes Protection Refer to Ordering Information Environmental Data <±1.5% of FS 10k Ohms, min. 10k Ohms, min. Yes No Pressure Ranges* Temperature Operating -40 to 85˚C (-40 to 185˚ F) Storage -40 to 100˚C (-40 to 212˚ F) Thermal Limits Compensated Range 0 to 55˚C (30 to 130˚ F) TC Zero <±1.5% of FS (<±3.0 % for 25 psig) TC Span <±1.5% of FS Other Gage psig Proof psig Burst psig Pressure Range Code 0-25* 50 250 00025 0-50 100 250 00050 0-100 200 500 00100 0-200 400 1,000 00200 0-500 1,000 2,500 00500 0-1,000 2,000 5,000 01000 0-2,500 5,000 12,500 02500 Shock 100G, 11msec, 1/2 sine 0-5,000 10,000 20,000 05000 Vibration 10G Peak, 20 to 2000 Hz 0-7,500 15,000 20,000 07500 EMI/RFI Protection Yes 0-10,000 20,000 20,000 10000 Rating IP-66 with housing and cable seal only. IP-54 w/o housing Other ranges available, please consult factory. *Output = 5mV/V Specifications are subject to change without notice. 3 Series 42 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 42-H-00500-B-3-B-0-000 Series Type Process Connection 42 X= Special Panel Mount H= 1/8" FNPT S= 1/2" FNPT Pressure Range Pressure Unit Outputs Electrical Interface Wetted Material Options XXXXX= Special X= Special X= Special X= Special X= Special XXX= Special B= BAR A= 0-50mV/V A= 2ft. cable 0= 17.4 PH 000= No options K= kg/cm B= 20mV/V B= 4ft. cable 1= 316 L A10= ±0.10 accuracy P= psig G= 1-10V C= 6ft. cable 2= Inconel A25= ±0.25 accuracy W= Inches of H2O column 1= 10mV/V D= 10ft. cable C01 Calibration 1-9 3= 1-5V G= 4 pin Molex connector C10 Calibration 10-49 Insert pressure range code from pressure range chart. Vacuum = V0000 -14.7psig/-1.01bar For vacuum replace first zero with (V) in pressure code. (Ex. V0500 = Vacuum to 500 psig) 2 4= 4-20mA 5= 5mV/V 6= 1-6V C50 Calibration 50-up H= Flex strip 3" C0S Cleaned for O2 service J= 15ft. cable K= 8ft. cable T= 25ft. cable Dimensional Information Configuration allows epoxied or TIG welded housing attachment (0.810" ID / 0.875" OD) (V+) Supply (S+) Output (S-) Output (V-) Supply 4-pin Molex Connector (Mating connector is Molex p/n 22-01-3047 with pins p/n 08-50-0114) NOTE: 1. Use Greenlee Punch Unit #60086 to prepare the panel hole. Also available from McMaster-Carr as #3449A65. Jacketed Cable, 2 ft. long, 0.177" dia. Table 1 Output 1-5V 4-20mA 4 Pin 3 Pin 2 Pin 1 +V Supply +V Supply -V Supply -V Supply Output N/C 4 Series 43 Hazardous Locations Series Stainless Steel Media Isolated Pressure Sensor 43 Features • Class I Div. 2, Groups A, B, C, and D for use in hazardous locations • High strength stainless steel construction • No silicone oil, no internal o-rings, no welds • Wide operating temperature range • Ranges up to 10,000 psig • Rugged design survives harsh environments • Compatible with wide range of gases and liquids • Suitable for high shock and vibration applications Specifications Performance @ 25˚C (77˚F) Accuracy1 <±0.25% BFSL Stability (1 year) ±0.25% FS, typ. Proof Pressure 2X Rated Pressure Burst Pressure 5X or 20,000 psig, whichever is less Pressure Cycles > 100 Million Electrical Data Output 4-20mA 1-5VDC, 1-6VDC 0.5-4.5 V ratiometric Excitation 10-28VDC 10-28VDC 5VDC, reg Output Impedance >10k Ohms <100 Ohms, nom. <100 Ohms, nom. Current Consumption 20mA, typ. <10mA <10mA Bandwith (-3dB): DC to 250 Hz DC to 1kHz DC to 1kHz Output Noise: - <2mV RMS <2mV RMS Physical Description Zero Offset <±1% of FS <±1% of FS <±1% of FS Case Span Tolerance <±2% of FS <±1.5% of FS <±1.5% of FS 10k Ohms, min. 10k Ohms, min. Yes No 1 Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability 304 stainless steel See load line curve below Electrical Connection Refer to Ordering Information Output Load Wetted Material Reverse Polarity Yes Protection Refer to Ordering Information Pressure Ranges*+ Environmental Data Temperature Operating -40 to 85˚C (-40 to 185˚ F) Storage -40 to 100˚C (-40 to 212˚ F) Thermal Limits Compensated Range 0 to 55˚C (30 to 130˚ F) TC Zero <±1.5% of FS (2.0% for 316L) TC Span <±1.5% of FS (2.0% for 316L) Other Gage psig Proof psig Burst psig Pressure Range Code 0-25 50 250 00025 0-50 100 250 00050 0-100 200 500 00100 0-200 400 1,000 00200 0-500 1,000 2,500 00500 0-1,000 2,000 5,000 01000 0-2,500 5,000 12,500 02500 Shock 100G, 11msec, 1/2 sine 0-5,000 10,000 20,000 05000 Vibration 10G Peak, 20 to 2000 Hz 0-7,500 15,000 20,000 07500 EMI/RFI Protection Yes 0-10,000 20,000 20,000 10000 Rating IP-66 * Typical Ranges. All ranges between 0-25 psig and 0-10,000 psig are available. Please consult factory. + Vacuum calibration available. Please consult factory. Specifications are subject to change without notice. 5 Series 43 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 43-A-00500-B-3-L-0-000 Series Type Process Connection 43 X= Special Hazardous Locations A= 1/4" MNPT C= 1/4" BSPP Male E= 1/2" MNPT J*= 1/4" FNPT S*= 1/2" FNPT X= Special X= Special X= Special X= Special XXX= Special B= BAR B= 20mV/V F= 55 meter cable 0= 17.4 PH 000= No options K= kg/cm2 G= 1-10V J= 15ft. cable 1= 316 L P= psig 1= 10mV/V K= 8ft. cable 2= Inconel Insert pressure range code from pressure range chart. Vacuum = V0000 -14.7psig/-1.01bar Table 1 Red Black White +V Supply +V Supply -V Supply -V Supply Output N/C Table 1 6 Options XXXXX= Special Dimensional Information Output 1-5V 4-20mA Wetted Material Pressure Unit * 316L not available For vacuum replace for FNPT sizes first zero with (V) in pressure code. (Ex. V0500 = Vacuum to 500 psig) Output 1-5V 4-20mA Electrical Interface Pressure Range Red Black White +V Supply +V Supply -V Supply -V Supply Output N/C Outputs W= Inches 2= 0.5-4.5V of H2O ratiometric column 3= 1-5V 4= 4-20mA 2 wire 5= 5mV/V 6= 1-6V L= 2ft. cable w/conduit M= 4ft. cable w/conduit N= 6ft. cable w/conduit P= 10ft. cable w/conduit T= 25ft. cable 001= Etched name plate A10= ±0.10 Accuracy C01 Calibration 1-9 C10 Calibration 10-49 C50 Calibration 50-up C0S Cleaned for O2 service 4 Series 44 Series Intrinsically Safe 44 Stainless Steel Media Isolated Pressure Sensor Features • Class I Div. 1, Groups C&D Intrinsically Safe • High strength stainless steel construction • No silicone oil, no internal o-rings, no welds • Wide operating temperature range • Ranges up to 10,000 psig • Rugged design survives harsh environments • Compatible with wide range of gases and liquids • Suitable for high shock and vibration applications Specifications Performance @ 25˚C (77˚F) Accuracy1 <±0.25% BFSL Stability (1 year) ±0.25%FS, typ. Proof Pressure 2X Rated Pressure Burst Pressure 5X or 20,000 psig, whichever is less Wetted Material 17.4 PH S.S. (NACE compatible) (for other material consult factory) Pressure Cycles 1 > 100 Million Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability Physical Description Case Output 4-20mA 1-5VDC, 1-6VDC 0.5-4.5 V ratiometric Excitation 10-28VDC 10-28VDC 5VDC, reg Output Impedance >10k Ohms <100 Ohms, nom. <100 Ohms, nom. Current Consumption 20mA, typ. <10mA <10mA Bandwith (-3dB): DC to 250 Hz DC to 1kHz DC to 1kHz Output Noise: - <2mV RMS <2mV RMS Zero Offset <±1% of FS <±1% of FS <±1% of FS <±1.5% of FS <±1.5% of FS 10k Ohms, min. 10k Ohms, min. Yes No Span Tolerance <±2% of FS 304 stainless steel Electrical Connection Refer to Ordering Information Wetted Material Electrical Data Refer to Ordering Information Output Load See load line curve below Reverse Polarity Yes Protection Pressure Ranges*+ Environmental Data Gage psig Temperature Proof psig Burst psig Pressure Range Code Operating -40 to 85˚C (-40 to 185˚ F) 0-25 50 250 00025 Storage -40 to 100˚C (-40 to 212˚ F) 0-50 100 250 00050 0-100 200 500 00100 0-200 400 1,000 00200 Thermal Limits Compensated Range 0 to 55˚C (30 to 130˚ F) TC Zero <±1.5% of FS (2.0% for 316L) 0-500 1,000 2,500 00500 TC Span <±1.5% of FS (2.0% for 316L) 0-1,000 2,000 5,000 01000 0-2,500 5,000 12,500 02500 0-5,000 10,000 20,000 05000 Other Shock 100G, 11msec, 1/2 sine Vibration 10G Peak, 20 to 2000 Hz 0-7,500 15,000 20,000 07500 EMI/RFI Protection Yes 0-10,000 20,000 20,000 10000 Rating IP-66 * Typical Ranges. All ranges between 0-25 psig and 0-10,000 psig are available. Please consult factory. + Vacuum calibration available. Please consult factory. Specifications are subject to change without notice. 7 Series 44 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 44-A-00500-B-3-B-0-000 Series Type Process Connection X= Special 44 Intrinsically A= 1/4" MNPT Safe B= 1/8" MNPT C= 1/4" BSPP Male E= 1/2" MNPT Pressure Range Pressure Unit Outputs Electrical Interface Wetted Material XXXXX= Special X= Special X= Special X= Special X= Special XXX= Special B= BAR A= 0-50mV/V A= 2ft. cable 0= 17.4 PH 000= No options B= 20mV/V B= 4ft. cable 1= 316 L A10= ±0.10 accuracy P= psig G= 1-10V C= 6ft. cable 2= Inconel C01 Calibration 1-9 W= Inches of H2O column 1= 10mV/V D= 10ft. cable C10 Calibration 10-49 2= 0.5-4.5V ratiometric E= Mini DIN 43650 C50 Calibration 50-up F= Packard Metripack C0S Cleaned for O2 service Insert pressure range code from pressure range chart. K= kg/cm Vacuum = V0000 F= 7/16"-20 UNF Male -14.7psig/-1.01bar H= 1/8" FNPT For vacuum replace first zero with (V) in J= 1/4" FNPT pressure code. S= 1/2" FNPT (Ex. V0500 = Vacuum to 500 psig) 2 3= 1-5V 4= 4-20mA 2 wire J= 15ft. cable 5= 5mV/V K= 8ft. cable 6= 1-6V T= 25ft. cable Options 7= 1-5V adj. 8= 4-20mA adj. 9= 1-6V adj. Dimensional Information Class I, Div. 1, Groups C, D Hazardous Location The transducers listed below are designed for installation in a Class I, Division 1, Groups C and D, Division 1 hazardous location when connected to Associated Apparatus as described in note 1. Nonhazardous Location Entity Parameters Vmax = 28Vdc Imax = 175mA Imax is the total current available from the Associated C1 = 0.44uf Apparatus under any condition. L1 = 0 Hazardous Location Red Black 44X0 mV output 4 /PA Green White Intrinsic Safety Barrier 2 signal + signal - PA/ 3 4 /PA Intrinsic Safety Barrier Notes: 1. Associated Apparatus shall provide intrinsically safe connections which meet the following parameters. Voc or Vt £ Vmax Ca ≥ C1 + Cleads Isc or It £ Imax La ≥ L1 + Lleads PA/ Ground Bus Figure 1: Wiring diagram for 4-wire, mV output 2. Control Room aparatus shall not generate in excess of 250V (Umax). I. S. ground conductor 3. Installation should be in accordance with Article 504 in the National Electrical Code, ANSI/NFPA 70. Table 1 Nonhazardous Location Hazardous Location 44X0 4-20 mA output 2 excitation + excitation - 3 Red Black supply voltage 3 4 /PA Intrinsic Safety Barrier 2 PA/ RL Ground Bus Figure 2: Wiring diagram for 2-wire, 4-20mA output 44X0 Voltage output Nonhazardous Location Red White Black Figure 3: Wiring diagram for 3-wire, Voltage output 8 supply common I. S. ground conductor Hazardous Location supply voltage signal common 3 4 /PA Intrinsic Safety Barrier Output 1-5V 4-20mA 2 PA/ Ground Bus common I. S. ground conductor analog input Pin 3 Pin 2 Pin 1 +V Supply +V Supply -V Supply -V Supply Output N/C 4 Series 45 Series Stainless Steel Tank Level Sensor 45 Features • High strength stainless steel construction • No silicone oil, no internal o-rings, no welds • Wide operating temperature range • Ranges up to 100 psig • Rugged design survives harsh environments • Compatible with wide range of gases and liquids • Suitable for high shock and vibration applications Specifications Performance @ 25˚C (77˚F) Accuracy1 <±0.5% BFSL (for higher accuracy, please consult factory) Stability (1 year) ±0.25%FS, typ. Over Range Pressure 2X Rated Pressure Burst Pressure 5X or 1250 psig, whichever is less Pressure Cycles > 50 Million Agency Approval UL 508 Electrical Data Output 4-20mA 1-5VDC Excitation 10-28VDC, typ. 10-28VDC, typ. Output Impedance <10k Ohms <100 Ohms, nom. Current Consumption 20mA, typ. <10mA Bandwidth (-3dB) DC to 250Hz DC to 1kHz Electrical Connection Refer to Ordering Information Output Noise - <2mV RMS Wetted Material Zero Offset <±1% of FS <±1% of FS Span Tolerance <±2% of FS <±1.5% of FS Output Load See load line curve below 10k Ohms, min. Reverse Polarity Yes Yes 1 Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability Physical Description Case 304 stainless steel Refer to Ordering Information Environmental Data Temperature Operating -40 to 85˚C (-40 to 185˚ F) Storage -40 to 100˚C (-40 to 212˚ F) Thermal Limits Compensated Range 0 to 55˚C (-30 to 130˚ F) Temp. Comp. Zero <±1.5% of FS (<±2.0% for 316L) Temp. Comp. Span <±1.5% of FS (<±2.0% for 316L) Other Shock 100G, 11msec, 1/2 sine Vibration 10G Peak, 20 to 2000 Hz Rating IP-68 EMI/RFI Protection Yes Pressure Ranges* Gage psig Proof psig Burst psig Pressure Range Code 0-15 30 125 00015 0-25 50 125 00025 0-30 60 150 00030 0-100 200 500 00100 * Typical Ranges. All ranges between 0-15 psig and 0-100 psig are available. Please consult factory. 9 Series 45 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 45-L-00100-B-3-C-1-000 Series Type Process Connection Pressure Range Pressure Unit Outputs Electrical Interface Wetted Material Options 45 Standard X= Special XXXXX= Special X= Special X= Special X= Special X= Special XXX= Special B= BAR 3= 1-5V C= 6ft. cable 1= 316 L 000= No options 4= 4-20mA D= 10ft. cable L= Cone Front Insert pressure range code from pressure range chart. K= kg/cm 2 P= psig J= 20ft. cable K= 25ft. cable L= 35ft. cable M= 50ft. cable N= 100ft. cable P= 150ft. cable Hytrel cable available, consult ASCO Dimensional Information Line Impedance 4-20mA Load line Curve Table 1 Output Red Black +V Supply -V Supply Output 4-20mA +V Supply -V Supply N/C Supply Voltage Jacketed Cable, Length Specified per Order, 0.30 dia. 0.88 4.43 Shield Red (see table 1) White (see table 1) Black (see table 1) Vent Tube 10 White 1-5V 4 Series 46 Series Stainless Steel Explosionproof Pressure Sensor 46 Features • High strength stainless steel construction • No silicone oil, no internal o-rings, no welds • Wide operating temperature range • Ranges up to 10,000 psig • Rugged design survives harsh environments. • Compatible with wide range of gases and liquids • Suitable for high shock and vibration applications Specifications Performance @ 25˚C (77˚F) Accuracy1 <±0.25% BFSL Stability (1 year) ±0.25% FS, typ. Proof Pressure 2X Rated Pressure Burst Pressure 5X or 25,000 psig, whichever is less Pressure Cycles > 100 Million CSA 30 (UL 1203) Class 1, Div. 1 Explosionproof, Groups A,B,C & D Electrical Data Output 4-20mA 1-5V, 1-6V Excitation 10-28VDC, typ. 10-28VDC Output Impedance <10k Ohms <100 Ohms, nom. Current Consumption 20mA, typ. <10mA Physical Description Bandwidth (-3dB) DC to 250Hz DC to 1kHz Case Output Noise - <2mV RMS Electrical Connection Refer to Ordering Information Zero Offset <±1% of FS <±1% of FS Wetted Material Span Tolerance <±2% of FS <±1.5% of FS Output Load See load line curve below 10k Ohms, min. Reverse Polarity Yes Yes Agency Approval 1 Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability 304 stainless steel Refer to Ordering Information Environmental Data Temperature Operating Storage Thermal Limits Compensated Range Temp. Comp. Zero Temp. Comp. Span Other Shock Vibration EMI/RFI Protection Rating -40 to 85˚C (-40 to 185˚F) -40 to 100˚C (-40 to 212˚F) Pressure Ranges* Gage psig Proof psig Burst psig Pressure Range Code 0-50 100 250 00050 0-100 200 500 00100 0-200 400 1,000 00200 0-250 500 1,250 00250 0-500 1,000 2,500 00500 100G, 11msec, 1/2 sine 10G Peak, 20 to 2400 Hz 0-1,000 2,000 5,000 01000 0-2,000 4,000 10,000 02000 Yes 0-2,500 5,000 12,500 02500 IP-66 0-5,000 10,000 20,000 05000 0-7,500 15,000 20,000 07500 0-10,000 20,000 20,000 10000 0 to 55˚C (30 to 130˚ F) <±1.5% of FS <±1.5% of FS * Typical Ranges. All ranges between 0-50 psig and 0-10,000 psig are available. Please consult factory. 11 Series 46 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 46-A-00500-P-3-U-0-000 Series Type Process Connection Pressure Range Pressure Unit Outputs Electrical Interface Wetted Material Options 46 Standard X= Special XXXXX= Special X= Special X= Special X= Special X= Special XXX= Special B= BAR 3= 1-5V* T= 2ft. cable, 18AWG wire 0= 17.4 PH K= kg/cm 4= 4-20mA** U= 4ft. cable, 18AWG wire 1= 316L P= psig 6= 1-6V A= 1/4" MNPT E= 1/2" MNPT J= 1/4" FNPT Insert pressure range code from pressure range chart. 2 000= No options 2= Inconel 718 * 3 wire case connection ** 2 wire 100p powered and case conneciton Dimensional Information Line Impedance 4-20mA Load line Curve Table 1 Output White Black 1-5V +V Supply -V Supply Output Common +V Supply -V Supply Not Used Common Plasma TIG welds offering Continuous Air Tight Seal Color Coded Hookup Wires, 2 ft., 18 ga. 1/4 MNPT 1/2 MNPT 7/8" Hex Red (see table 1) White (see table 1) Black (see table 1) Green, Connected to housing (see table 1) Green 4-20mA 3.64 Supply Voltage 12 Red 4 Series 47 Series 47 Stainless Steel High Accuracy Pressure Sensor Features • High strength stainless steel construction • No silicone oil, no internal o-rings, no welds • Wide operating temperature range • Ranges up to 10,000 psig • Low static and thermal errors • High accuracy • Rugged design survives harsh environments • Compatible with wide range of gases and liquids • Suitable for high shock and vibration applications Specifications Performance @ 25˚C (77˚F) Electrical Data Accuracy1 <±0.25% BFSL (option of ±0.1%) Output 4-20mA Voltage (3 or 4 wire) Frequency (1-6kHz) 5VDC Stability (1 year) ±0.25%FS, typ. Excitation 10-28VDC 10-28VDC 10-28VDC 0-50mV - <100 Ohms nom. 10K, pull up 1100 Ohms nom. <10mA <15mA <5mA DC to 250Hz DC to 5kHz min. *Over Range Protection 2X Rated Pressure *Burst Pressure 5X or 20,000 psig, whichever is less Pressure Cycles > 100 Million 1 Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability Output Impedance Current 20mA max. Consumption Bandwidth (-3dB) DC to 250Hz DC to 1kHz Physical Description Output Noise NA <2mV RMS <2mV RMS NA Case Zero Offset <±1% of FS <±1% of FS <±1% of FS <±2% of FS Span Tolerance <±2% of FS <±1.5% of FS <±1.5% of FS <±2% of FS Output Load See load line curve 10k Ohms min. 10k Ohms min. >1M Ohms Reverse Polarity Protection Yes Yes Yes NA 304 stainless steel Electrical Connection Refer to Ordering Information Wetted Material Refer to Ordering Information Environmental Data Temperature Operating Storage Thermal Limits -40 to 85˚C (-40 to 185˚F) -40 to 125˚C (-40 to 250˚F) Compensated Range 0 to 55˚C (30 to 130˚ F) Temp. Comp. Zero <±1.5% of FS (±2.0% for 316L) Temp. Comp. Span <±1.5% of FS (±2.0% for 316L) Other Shock Vibration EMI/RFI Protection Rating 100G, 11msec, 1/2 sine 10G Peak, 20 to 2400 Hz Yes IP-66 Pressure Ranges*+ Gage psig 0-15 0-25 0-50 0-100 0-200 0-500 0-1,000 0-2,500 0-5,000 0-7,500 0-10,000 Proof psig 30 50 100 200 400 1,000 2,000 5,000 10,000 15,000 20,000 Burst psig 200 250 250 500 1,000 2,500 5,000 12,500 20,000 20,000 20,000 Pressure Range Code 00015 00025 00050 00100 00200 00500 01000 02500 05000 07500 10000 * Typical Ranges. All ranges between 0-25 psig and 0-10,000 psig are available. Please consult factory. + Vacuum calibration available. Please consult factory. Specifications are subject to change without notice. 13 Series 47 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 47-A-00500-P-3-B-0-000 Series Type Process Connection Pressure Range Pressure Unit Outputs Electrical Interface Wetted Material Options 47 Standard X= Special XXXXX= Special X= Special X= Special X= Special X= Special XXX= Special B= BAR 2= 0-5V (3 wire) A= 2ft. cable 0= 17.4 PH 000= No options K= kg/cm2 3= 1-5V B= 4ft. cable 1= 316L P= psig 4= 4-20mA C= 6ft. cable 5= 0-10V (3 wire) D= 10ft. cable 6= 1-6kHz E= Mini DIN 43650 7= 0-5V (4 wire) F= Bendix 6 pin connector A= 1/4" MNPT Insert pressure range code F= 7/16" -20 UNF from pressure range chart. Male B= 1/8" MNPT Vacuum = V0000 -14.7psig/-1.01bar For vacuum replace first zero with (V) in pressure code. (Ex. V0500 = Vacuum to 500 psig) 8= 0-10V (4 wire) Dimensional Information Electrical Connections - Cable Only Cable Output Type Green mV, 0-5V, 0-10V +S -V +V -S (Output) (Supply) (Supply) (Output) Red White 0.5-4.5V, 1-5V,1-6V S -V +V N/C (Output) (Supply) (Supply) 4-20mA N/C -V +V N/C (Supply) (Supply) 4-20mA Load line Curve Mini DIN 43650 Pin 2 Pin 3 Jacketed Cable, 0.177 dia. Output Type Pin 1 mV, 0-5V (4-wire), 0-10V(4-wire) +S -V +V -S (Output) (Supply) (Supply) (Output) Wide Pin Line Impedance Black 0-5V (3-wire), 1-5V, S -V +V N/C 0-10V(3-wire) (Output) (Supply) (Supply) 4-20mA N/C Shrink Tubing, 3/8" dia. Supply Voltage -V +V N/C (Supply) (Supply) 1.0 2.61 6-pin Bayonet (Bendix) Output Type 14 Pin A Pin B Pin C Pin D Pin E Pin F mV, 0-5V, 0-10V +V +Signal -Signal -V -V N/C 1-5V, 1-6V, 1-10V +V Output N/C -V -V N/C 4-20 mA +V -V N/C N/C N/C N/C 4-20 mA +V -V N/C N/C Shunt Shunt 0.40 0.875" HEX 1/4" MNPT Thread 4 Series 50 Series 50 Stainless Steel, Wet/Wet Differential Pressure Sensor Features • Compact and rugged design • High strength stainless steel construction • No internal fluid filled cavities • No Internal o-rings • Wide operating temperature range • Low static and thermal errors • EMI/RFI protection to 100V/m • Suitable for high shock and vibration applications Specifications Performance @ 25˚C (77˚F) Line Pressure Measurement Range Proof Pressure 0-100 to 1,000 psig (0-7, 0-17, 0-35 and 0-70 bar) 20% of line pressure, minimum Rated line pressure on either P1 or P2 Electrical Data Burst Pressure 5X or 2000 psi, whichever is less Output 4-20mA Voltage (1-5V, 1-6V) 0.5-4.5V ratiometric Accuracy1 <±0.3% BFSL Excitation 10-30VDC 10-30VDC 5VDC, reg Pressure Cycles > 10 Million Output Impedance - <100 Ohms, nom. <100 Ohms, nom. Current Consumption 25mA <10mA <10mA 1 Accuracy includes: Non-linearity, Hysteresis, and Non-repeatability Bandwith (-3dB): DC to 250 Hz DC to 1kHz DC to 1kHz Output Noise: 0-800 Ohms <2mV RMS @ 10-28VDC <2mV RMS Electrical Connection Refer to Ordering Information Zero Offset <±1% of FS <±1% of FS <±1% of FS Wetted Material Span Tolerance <±2% of FS <±1.5% of FS <±1.5% of FS 10k Ohms, min. 10k Ohms, min. Yes No Physical Description Case Pressure Port 304 stainless steel Refer to Ordering Information 1/8" NPT Output Load See load line curve below Reverse Polarity Yes Protection Environmental Data Temperature Operating Storage Thermal Limits Compensated Range Pressure Ranges* -40 to 85˚C (-40 to 185˚F) -40 to 100˚C (-40 to 212˚F) 0 to 55˚C (30 to 130˚ F) TC Zero <±1.5% of FS TC Span <±1.5% of FS Other Shock Vibration EMI/RFI Protection 100G, 11msec, 1/2 sine 10G Peak, 20 to 2000 Hz Yes Rating IP-66 DP Line Burst Range Pressure Pressure Measurement Code (psig), min. (psig), max. (psig) 0-30 100 500 0030 0-60 0-150 0-300 250 500 1,000 1,250 2,000 2,000 0060 0150 0300 Line Code 0100 0200 0500 1000 * Typical Ranges. All ranges between 0-30 psig and 0-300 psig are available. Please consult factory. 15 Series 50 4 Ordering Information Construct a product code using the chart below. (Consult factory for other options) 50-H-0500-P-3-B-0-0000 Series Type Process Connection 50 X= Special Standard H= 1/8" FNPT Line Pressure Range Pressure Unit Outputs Electrical Interface Wetted Material Measurement Range XXXXX= Special X= Special X= Special X= Special X= Special B= BAR A= 2ft. cable 0= 17.4 PH Insert pressure range code from pressure range chart. K= kg/cm2 2= 0.5-4.5V ratiometric B= 4ft. cable 1= 316L with Parylene-C coating (no options) Insert 4 digit measurement code from chart on specifications page. P= psig 3= 1-5V 4= 4-20mA 6= 1-6V Dimensional Information Line Impedance 4-20mA Load line Curve Supply Voltage Table 1 Output Red Black White Green 1-5V +V Supply -V Supply Output Common 4-20mA +V Supply -V Supply Not Used Common 3/4" (19mm) HEX 2.2 !/8 FNPT Both Ends 2.1 16 ASCO offers a complete catalog of products and accessories to satisfy any of your application needs. Visit us online at www.ascovalve.com to view our full line of products. Red-Hat Solenoid Valves The largest selection of 2, 3, and 4-way solenoid valves, designed to handle the most demanding fluid control applications. ASCO Scientific Highest quality micro-miniature solenoid valves for medical and analytical applications. Pneumatic Controls Directional control valves, air preparation equipment, actuators, and accessories for fluid power applications. Valve Monitoring Systems Integrated visual indication technology with network communication capabilities that revolutionizes position indication solutions. Next Generation Solenoids The Next Generation of solenoid valves provides lower operating cost, and represents and advancement in performance, reliability, and ruggedness that you have come to expect from ASCO. Process Automation Pilot valves and control accessories for reliable process solutions. Pressure and Temperature Sensing Devices for pressure and temperature monitoring. ASCO S Series Compact valve solutions for commercial applications. Canada Tel 519-758-2700 Australia Tel (61) 2-9-451-7077 Brazil Tel (55) 11-4208-1700 Germany Tel (49)-7237-9960 United Kingdom Tel (44) 1695-713600 China Tel (852) 2-343-8580 Mexico Tel (52) 55-3640-0200 France Tel (33) 1-47-14-32-00 Singapore Tel (65) 6556-1100 Japan Tel (81) 798-65-6361 18 A S C O Va l v e , I n c . • 8 0 0 . 9 7 2 . 2 7 2 6 • w w w. a s c o v a l v e . c o m V7366 R5 www.eci.co Sede Bogotá D.C, Colombia Transversal 18Bis No 38-41 Calle 23 No 116-31 Bod. 32 Tel: +57(1) 3275151 Fax: +57(1) 2884838 / 2885589 [email protected] [email protected] Sede Quito, Ecuador Suiza 361 y República de El Salvador Ed. Euro, Oficina 7B Tel: +593(2) 600 6882 Fax: +593(2) 333 2567