Catalogue 2012 - Section J Power Products
Transcription
Catalogue 2012 - Section J Power Products
Section J Power Products OVERHEAD LINE PRODUCTS Split Bolt Connectors J2 Full Tension Copper Sleeves J3 Parallel Groove Clamps - Copper, Aluminium & Bi-Metal J4 - J5 Insulation Piercing Connectors for ABC J6 - J7 House Service Connectors J8 - J9 Strain Clamps & Suspension Clamps for ABC Lugs & Sleeves for ABC J10 - J11 J12 Aluminium Sleeves - Overhead Line J13 - J14 Insulating Covers, Mats & Tiger Tails J15 Copper Braids J16 - J17 UNDERGROUND SYSTEMS Pits, Pillars & Fuse Panels & Shrouds, Labels & Accessories J18 - J28 URD Connection System with Crimp & Bolted Lugs J28 - J30 URD Terminal Blocks Portable Earthing Equipment, Earth Rod & C Connectors Warning Marker Tape & Guides J31 J33 - J35 J36 Cable Stockings & Accessories J37 - J40 Cable Installation Equipment J41 - J53 Manhole Guards & Tests J54 - J55 Split Bolt Connectors SBC - Split Bolt Connectors CABAC has a complete range of split bolts that are used for tapping or joining aerial hard drawn copper conductors or insulated copper conductors. The split bolts are made from a hard grade high conductivity brass with a captive saddle which applies a distributed pressure to conductors, to comply with ESAA specifications. The split bolts have the same head dimensions as the norm in the market so that a standard linesman’s spanner will fit. They can be supplied in natural brass or electro tinned. SPLIT BOLT CONNECTORS CatalogueCatalogue Max No. No. Conductor Natural Brass Electro Tinned Size (mm2) 7 –SBC12T 25 6.6 –50 SBC22SBC22T 16 5.3 Type A 50 SBC24SBC24T 35 8.3 Type B 50 SBC25SBC25T 70 10.9 Type C 25 SBC26SBC26T 95 12.9 Type D 20 SBC28SBC28T 185 18.5 Type E 5 3.9 Catalogue No. Kit Contents 3 x SBC22 2 x SBC24 1 x SBC25 1 x SBC26 A Part No A (mm) SBC9 19.5 SBC12 28.5 SBC22 30.0 SBC24 36.5 SBC25 44.5 SBC22 SBC26 50.8 SBC24 SBC28 66.8 Technical Data Split bolts with lug palm attachments for terminating onto air break switchgear. They are supplied electro tinned, with a 10 or 12mm hole in palm. SBC22L A SBC24L SBC26L SBC22T with Lug Palm SBC24T with Lug Palm SBC26T with Lug Palm Conductive Material : Copper alloy Operating Temperature : -55°C to 100°C Electroplating Material: Tin 99.7% pure Accepting Authorities Energy Australia Rail Services Australia Integral Energy Country Energy ENERGEX and many other recognised authorities. A C Part No. SBC22L SBC24L SBC26L A (mm) B(mm) C(mm) 52.00 19.00 75.00 25.50 85.00 31.75 3.25 3.25 3.25 B Split Bolt Shrouds • Plastic shroud for insulating split bolts SBC22SH SBC22 Plastic Covers 53.50mm 8mm 27mm Part No SBC9 SBC12 SBC25 SBC26 SBC - Split Bolt Connectors - Lug Palm Type SBC22L SBC24L SBC26L J2 Slot Width –100 Split bolts are available in handy merchandiser packs, for store merchandising. SBC22/K SBC24/K SBC25/K SBC26/K Slot Width A –SBC9T Part No. B Slot ESAA Box Width Cross- Qty (mm) Reference A (mm) B(mm) C(mm) 52.00 19.00 75.00 25.50 85.00 31.75 3.25 3.25 3.25 SBC28 Full Tension Copper Sleeves Copper Compression Sleeves Copper Compression Sleeves are designed to accommodate stranded hard drawn copper overhead conductors and comply with the full tension testing requirements of AS 1154.1. These sleeves are easily and quickly crimped onto the conductor using hexagonal dies and the HT51 hydraulic crimper, or any larger hydraulic crimper. The finished joint is shorter and less bulky than the McIntyre sleeve. It replaces twisting of the conductor required for the installation of McIntyre sleeves. CABAC’s Copper Compression Sleeves are made from 99.9% high conductivity copper. Plastic plugs are fitted into the ends of the sleeve to prevent foreign material entering the sleeve prior to crimping the conductor. Compression lines are marked on each end of the sleeve to indicate the position and the number of compressions required. An indent in the centre of the sleeve acts as an internal stop to ensure conductors are inserted to the correct length. L PT6 6 PT10 10 PT16 16 7/1.63, 7/1.70 PT25N 25 7/2.00, 7/2.03 PT35 35 PT42 42 PT50 50 PT70N 70 7/1.04, 7/1.12 80 81 M82-50 8.2 6 83 6.8 M96-50 9.6 6 7/2.62 115 8.5M115-50 11.5 5 7/2.75 115 9.0M132-50 13.2 5 19/1.70 115 9.5M132-50 13.2 5 115 11.0 15.8 5 ECW-H3D 4 M82-50 M148-50 MSS-C120-42-18V 8.2 5.2 HT131-UC 4.5M82-50 HT131-C, B131-C 4 19/2.00, 19/2.11 3.5 HT51 8.2 7/1.35 80 A/F No. of Hex Die Crimps (mm) per end PT95 95 19/2.56 196 13.0M190-50 19.0 8 PT134 134 19/3.00 195 16.5M190-50 19.0 8 Note: Contact CABAC Engineering Department before using a PT sleeve on any conductor that is not listed. Technical Data Conductive Material Copper 99.95% pure Oxygen Content 30 ppm Tensile Strength 200 MPa Ductile Rating 40% Final Metal State Fully annealed FULL TENSION COPPER SLEEVES Nominal Dimensions (mm) Catalogue Conductor Stranding Nominal Crimp Tooling No. (mm2) No./Dia. L ID Die 5 Tonne Operating Temperature -55°C to 100°C Plating Note this product is not plated due to limited shelf life expectancy. General Electrical Properties Total Conductivity 99.7% IACS Total Resistivity 1.738 micro-ohms cm Conformant Standards AS 1154 Accepting Authorities Energy Australia Electricity Services Victoria Rail Services Australia Energex Western Power - and many other recognised authorities. J3 Parallel Groove Clamps COPPER AND ALUMINIUM Copper Parallel Groove Clamps CABAC Copper Parallel Groove Clamps are used for tapping or joining hard drawn or annealed copper conductors. • These clamps are forged, not extruded, which creates a high strength clamp • Slotted holes allow adjustment for varying conductors on each side •H igh strength bolts, and tapped threads in the clamp base allow tightening to high torques with a single spanner • Forged design allows “gripping grooves” to be forged into the conductor clamp area, for greater conductivity, and pull strength Catalogue Conductor BoltDimensions (mm) Torque No. Range Dia. B L H (Nm) (mm2) One Bolt CUPG10/70 10-70 M8 372429 20 PARALLEL GROOVE CLAMPS Two Bolt CUPG6/70-2B 6-70 2 x M8 37 38 29 CUPG10/95-2B 10-95 2 x M10 45 46 36 44 CUPG16/150-2B 16-150 2 x M10 53 52 40 44 Technical Data Conductive Material Final Metal State Operating Temperature Conformant Standard Accepting Authorities Copper 99.95% pure Forged -55°C to 140°C AS1154 Ergon, Powercor Aluminium Parallel Groove Clamps CABAC Aluminium Parallel Groove Clamps are used for tapping or joining AAC, AAAC or ACSR overhead conductors. • These clamps are forged, not extruded, which creates a high strength clamp • Slotted holes allow adjustment for varying conductors on each side • Galvanised nuts and bolts allow tightening to high torques with a single spanner • Forged design allows “transverse gripping grooves” to be forged into the conductor clamp area, for greater conductivity, and pull strength Catalogue Conductor BoltDimensions (mm) No. Range Dia. B L H (mm2) Two Bolt ALPG16/70-2B 16-70 2 x M8 37 49 40 Torque (Nm) 20 ALPG16/120-2B 16-120 2 x M8 45 55 50 20 ALPG 35/185-2B 35-185 2 x M10 57 65 60 44 Three Bolt ALPG35/300-3B 35-300 3 x M10 65 105 70 44 Technical Data Conductive Material Final Metal State Operating Temperature Conformant Standard Accepting Authorities J4 20 Aluminium 99.6% pure Forged -55°C to 140°C AS1154 Ergon, Powercor Parallel Groove Clamps Bi-Metal Parallel Groove Clamps CABAC Bi-Metal Parallel Groove Clamps are used to tap or join copper conductor to aluminium overhead conductor AAC, AAAC or ACSR. • Forged from 99.6% pure aluminium • Copper inlay impact welded in one groove • Slotted bolts allow varying conductor sizes in each groove • Tightened onto the conductors using galvanised 8.8mm bolts • Galvanised nuts allow the clamp to be tightened with the use of a single spanner at higher torques • Beville washers maintain clamping pressure • Clamps are ultrasonically tested to check bonding between copper inlay and aluminium • Individually packed in plastic bags H B C A L L A Range (mm2) Aluminium Copper Dimensions (mm) B W H Bolt Torque Diameter (Nm) Two Bolt BPG70/50 BPG150/95 70-16 (11-5mm) 150-25 (16-6mm) 50-6 (9-2mm) 95-10 (13-4mm) 40 50 42 46 45 46 2 x M8 2 x M8 20 20 Three Bolt BPG185/185 BPG300/240 185-35 (19-7mm) 300-50 (23-9mm) 185-35(19-7mm) 240-35 (21-7mm) 98 106 56 65 66 76 3 x M10 3 x M10 44 44 Technical Data Conductive Material Aluminium 99.6% pure Copper stalk 99.95% pure Operating Temperature -55°C to 100°C Joint Interface Friction Welded Conformant Standard AS 1154 Accepting Authorities Energy Australia Country Energy Western Power - and many other recognised authorities. U Bolt Parallel Groove Clamp The U-Bolt Parallel Groove Clamp has been designed to assist in the quick and effective way for joining overhead lines together. It is available in both aluminium and bi metal version and is suited to size 95/240mm2. Catalogue ConductorDimensions (mm) Torque No. Range L W H (Nm) (mm2) ALPG95/240U95-240 83.5 62.5 83.0*80 Front View H L BPG95/240U^95-240 83.5 62.583.0*80 *This measurement includes the U-bolt height. The clamp is used at all times with the U-bolt, therefore making necessary the height to be inclusive of the U-bolt. ^Copper version available on request. PARALLEL GROOVE CLAMPS Catalogue No. H W Aluminium Bail Clamp The Aluminium Bail Clamp is used to connect a distribution line of a larger diameter to a smaller diameter service line. The cable size that can be adapted by the clamp is from 7 strand 2.25mm (6.75 mm dia.) cable to 19 strand 3.25mm (18.75mm dia.) cable. It is supplied with jointing compound already applied in the clamp. The U-Bar consists of tinned copper. This makes for a perfect Electrical connection with your service line. • Cast aluminium body for corrosion resistance, and reduced weight • Tinned copper U Bar for excellent Electrical conductivity • Pre-applied jointing compound in clamp • Can adapt different sizes of line cables To install, unscrew the 2 bolts in the clamp and insert cable into it. Tighten bolts with clamp correctly orientated, now using 2 split bolts, bolt the service line to the U-Bar. Once complete, the Aluminium Bail Clamp connection is complete. Technical Data Conformant Standard Weight AS3766 444g ALBC* Aluminium Bail Clamp *Available on request. J5 Insulation Piercing Connectors FOR ABC Insulation Piercing Connectors INSULATION PIERCING CONNECTORS CABAC’s IPC (Insulation Piercing Connectors) are used to tap off low voltage XLPE insulated Aerial Bundled Cable (ABC), using a unique insulation piercing technique. • Designed for all weather applications, corrosion resistant, ease of installation and low cost • Connections can be made fully live in minutes, without time consuming crimping, applying insulation or sealing compound • Body is moulded from tough, resilient, glass filled nylon for long service life exposed to weather (particularly sunlight) and is rounded to prevent damage to adjacent conductors • Hardware is stainless steel, which does not corrode, allowing the IPC to be undone at any time in the future. The bolt has a stainless steel pressure washer which maintains clamping pressure • Shear head is made from glass filled nylon, for controlled shear torque. Head of bolt is a double hexagonal arrangement which allows the IPC to be undone after shearing • Extra hard aluminium contact teeth cut through insulation without splitting and ensure proper penetration into the conductor and Electrical continuity without sacrificing the mechanical strength of the conductor • Aluminium teeth ensure compatibility with aluminium conductor and will not deteriorate due to stress corrosion • Rubber seals and grease prevent moisture entering the cable for long term performance • End caps provided are used to seal the end of the branch core • Suitable for Aluminium and Copper The IPC connectors are simply tightened onto the insulated conductor using a 13 mm spanner and have a hex nut that shears once the correct torque is attained. This installation can be done fully live since the IPC connector is insulated and the insulation is not removed from the conductor. IPC95/10 Catalogue Main Cable Branch Cable Fastener Fastener Torque No. Range (mm2) Range (mm2) No. x Size A/F (mm) (Nm) IPC35/3535-6 IPC95/6 35-6 1 13 11 Use IPC95/10 – will accommodate 6mm IPC95/1095-6 10-1.5 1 13 11 IPC95/3595-25 35-6 1 13 14 IPC95/95150-16 95-16 1 13 16 IPC150/35150-35 35-16 1 13 14 13 16 IPC150/95 IPC95/95 Use IPC95/95 - will accommodate 150mm IPC150/150150-70 150-70 2 Technical Data Conductive Material Aluminium Teeth 99.6% pure Final Metal State Hard Water Proofing Rubber seals & grease 6 kV withstand voltage test in water Temperature Tested to 125°C Conformant Standards AS4396 NF-C33020 (HN33S63) – France 1000 heat cycles test to IEC 20 (sec. 256) Designed for cable made to AS 3560 Accepting Authorities Energy Australia Integral Energy J6 IPC150/150 Insulation Piercing Connectors BARE WIRE TO INSULATION PIERCING CONNECTORS Insulation Piercing Connectors CABAC’s IPCB range are used to connect bare copper or aluminium conductors to Aerial Bundled Cable (ABC) style insulated conductors, with conventional IPC style piercing of the insulated conductor. Primary uses are: • To connect a main ABC run to an existing open main overhead system. This is primarily when an ABC run is strung in place of an existing overhead run that is being replaced or has been damaged, or when an ABC run is being connected to a existing bare overhead main • To connect a house, commercial or industrial service to a bare wire overhead open main. These connectors are based around the traditional IPC connectors used in ABC to ABC type connections. They are simply tightened onto the conductors using a shear head for torque control Features of the CABAC connectors are: • The contact bridges are made of tinned brass copper, which are designed for use with Copper or Aluminium conductors, which reduces the stock range. • Designed for all weather applications, with a grease filled rubber boot protecting the connection interface on the bare conductor, and the piercing teeth of the IPC connection • Connections can be made in minutes, without time consuming crimping, and stripping. Simply scratch brush the bare conductor after inserting the conductors then simply tighten the connector to shear point • The bodies of the connectors are made from tough resilient glass filled nylon for long service life and UV sunlight protection • Hardware is stainless steel, which does not corrode, allowing the IPC to be undone at any time in the future. The bolt has a stainless steel pressure washer which maintains clamping pressure • Shear head is made from glass filled nylon, for controlled shear torque. Head of bolt is a double hexagonal arrangement which allows the IPC to be undone after shearing • Connectors have end seals to seal the end of the insulated conductor Installation practice is very similar to traditional IPC connectors. The bare conductor should be scratch brushed and the bare and insulated conductors inserted in the jaws and the connector tightened with a 13mm spanner until the shear head breaks. IPCB150/150 CABAC has a variation of these connectors specifically designed for Bare to House Service Connections. See page D9. Bare Insulated Catalogue Conductor Conductor No. of Fastener Torque No Range (mm2) Range (mm2) Bolts A/F (mm) (Nm) IPCB120/35120-6 35-6 1 13 14 IPCB150/95150-22 95-16 1 13 16 IPCB150/150150-22 150-35 2 13 16 IPCB150/95 INSULATION PIERCING CONNECTORS IPCB120/35 Technical Data Conductive Material Brass Copper Tinned Water Proofing Rubber seals and grease Conformant Standards AS4396 HN 33 E 61 - (France) Designed for cable made to AS3560 J7 House Service Connectors House Service Connector Series CABAC’s House Service Connectors are designed to optimise connection of overhead aluminium service conductors to the copper service in a consumer premises. The connectors have simple hex heads to bolt up the connector, the aluminium end being the piercing type with a shear head, and the copper end a conventional screw down style. • Fully waterproof due to moulded seals and greased filled • Consumer end (copper end) can be disconnected. The connectors can be used once only • The consumers side of the HSC is grey for identification • The connector excludes air and water and is fully bi-metal • Connector and attaching screws are fully insulated to guard installers and users HOUSE SERVICE CONNECTORS • Large range on both ends 6 to 35mm2. • A special variation of the connector is available with a neutral bond for metal facia installations. To install, simply slip the insulated aluminium conductor in the service cable end (this is clearly marked) and screw down the shear head screw until it shears. The consumers copper end must be stripped to the length indicated on the body of the connector and then inserted into the connector and the service end screw tightened. Tail End of HSC356NL Conductor Range (mm2) CatalogueConnector Consumer House No. Type Mains End - AL End - CU HSC356Standard HSC356NL Neutral Bond 6-356-35 HSC356NL HSC356 House Service Connector Series 3 The HSC356N-S3 & HSC356-S3 are a unique new design of connector with improved bi-metal connection capability. The HSC356N-S3 has double bolt connections & inspection windows for added connection security for neutral & earth conductors. PATENTED CONNECTION SYSTEM Conductor Range (mm2) CatalogueConnector Consumer House No. Type Mains End - AL End - CU HSC356-S3Standard HSC356N-S3Neutral/Earth Double Bolt 6-356-35 HSC356-S3 NEW HSC356-S3 J8 HSC356N-S3 HSC356N-S3 Bare Wire to House Service Bare Wire to House Service Connector The CABAC HSH connectors are designed to clamp on to aluminium or copper overhead lines and directly connect to an insulated overhead service main to the house using insulation piercing (IPC) technology. Available in aluminium or copper alloy with a single bolt for active and a double bolt for neutral/earth connections. To install connectors, best practice requires that the overhead mains conductor is scratch brushed prior to installation. The service connection can be done before or after the main connection. The bolts should be tightened until the head shears off. Catalogue No. Type Material Conductors Max (mm2)Number HSHCU35-V2Standard Copper 135 1 HSHAL35-V2StandardAluminium 135 1 HSHCU35-2BNeutral/Earth Copper 135 1 HSHAL35-2BNeutral/EarthAluminium 135 1 BARE WIRE TO HOUSE SERVICE Features are: • S ervice range from 16 to 35mm2. Aluminium connected using IPC system, and shear off bolts to establish the correct torque • Service connection is protected against moisture ingress by end seal, and IPC area is filled with grease • Clear viewing window at the end of the service connection allows a check of the conductor depth • The line side clamp connects to a large range of sizes and incorporates serrations in the clamp to grip the conductor •Q uick and easy to install with low operator skill, and basic installation tools • True bi-metal service side connection • Clear inspection window • Thermoplastic M13 Shearhead bolt • Shearhead colour coded yellow to indicate bolt has sheared Technical Data Material Aluminium Alloy 6005 A Temper T5 to AS2848.1 Copper Alloy 385 to AS1567 Bolts: 13 A/F Torque: 14 N/m HSHCU35-V2 and/or HSHAL35-V2 REGISTERED DESIGN NEW HSHCU35-2B and/or HSHAL35-2B J9 Strain Clamps & Suspension Clamps for ABC House Service Strain Clamp Strain Clamp for house service connections typically from a pole to a fascia board. Features stainless steel bail which is designed to “break” when trees fall on the wires. • Accommodates from two to four conductors from 16 to 35mm2 • Unique captive wedge system for automatic clamping of conductors, reduces installation time and requires no tools • The wedge system allows sag adjustments to be done at any time very easily without tools • UV stabilised for long term exposure to sunlight. • Designed to “break” at nominal 2 KN load to minimise damage to fascia boards and poles by falling trees etc. SCHS6/35 STRAIN CLAMPS SUSPENSION CLAMPS FOR ABC Technical Data Material Glass reinforced nylon Conformant Standard AS 3766 Working Tensile Load 1 KN Capacity 2 x 16 - 4 x 35mm2 Weight0.09kg Ultimate Tensile Load Less than 2 KN Dead End Strain Clamps These strain clamps are used mainly as a dead end anchor on ABC installations to anchor runs at regular intervals, or at the end of runs. CABAC offers two clamps, one with a capacity of 25 to 95mm2 and another 95 to 150mm2. • SC4/95 has galvanised steel arms • SC95/150 has aluminium arms with a wide throat • The clamping jaws are made from glass reinforced plastic SC4/95 Cable range 4 x 25 to 95mm2 SC95/150 Cable range 4 x 95 to 150mm2 Technical Data Conformant Standard Working Tensile Load AS3766 15KN (SC4/95) Suspension Clamp Type SPC This clamp is designed to suspend four by 95mm2 ABC conductors. It is made from hot dipped galvanised steel with a EDPM rubber insert. • This clamp is designed to hold all parts captive so that components cannot be dropped • The bolt is captive and is tightened with a simple wing nut. It is designed to hold 4 by 95mm2 • Very quick and simple to install • Will allow up to 30° line deviation To install the conductors simply remove and open the rubber insert, slip over the conductor bundle, and back into the clamp. Simply tighten the wing nut on the captive bolt and you have a completed suspension clamp. SPC4/95 Technical Data Conformant Standard AS 3766 Weight 0.42kg J10 Strain Clamps House Service Strain Clamp A multiple use house service strain clamp for use typically between the pole and the fascia board. • The clamp uses modular components to enable a large range of cable re-straining combinations to be offered • The steel components are all hot dipped galvanised to Australian Standard • The clamp can be configured for two or four conductors from 10mm to 35mm2 • Clamps with open hook ends have a spring retainer to stop the clamp becoming unhooked in high wind situations • The unique design of the plastic wedge pieces enables the cable direction to adapted to a 90 degree opposite configuration if required • All plastic components are moulded from glass filled reinforced nylon UV stabilised for long term exposure to sunlight Catalogue No. of Cables Dimensions (mm) No. A B C D E Short Clamps - Hook End with Spring SCSHS/2 2 way 1704055060 SCSHS/4 4 way SCSC/4 4 way STRAIN CLAMPS Short Clamps - Closed End SCSC/2 2 way 1704055060 Long Clamps - Hook End with Spring SCLHS/2 2 way 2704055060 SCLHS/4 4 way Long Clamps - Closed End SCLC/2 2 way SCLC/4 4 way 2704055060 SC Closed End Style Strain Clamp SC Hook End Style Strain Clamp J11 Lugs and Sleeves for ABC Pre-Insulated Bi-Metal ABC Tension Sleeves CABAC’s MJPT Sleeves are used for full tension joining of ABC (Aerial Bundled Conductor) cables. The pre-insulated compression sleeve consists of a 1050A aluminium tube coated internally with contact grease and a stop to ensure that the conductors are correctly positioned. The sleeve is insulated by means of a strong sheath of thermoplastic polymer material and has ends with an additional insulation ring coloured to indicate the size of conductor. The linesman’s job is made easier by markings that show: •Positions and crimping order • Length of insulation to be stripped from the cable core • Die size required • Fitting reference code • Colour code to select size A 3 2 4 STRIPPING LENGTH 5 MJPT15015.5 19.5 125 21.5 ECW-H3D HT51 CatalogueDimensions (mm) Die A/F No. A B L (mm) Tooling MJPT95 12.5 16.5 12521.5 HT131-C, HT131-UC, RHC131, RHU131-C, B131-C LUGS AND SLEEVES FOR ABC Installation • Strip the conductor to the right length (L indicated on the sheath) • Slide the sleeve on the conductor until it stops • Crimp the sleeve with correct hex die in the order marked on the sleeve • Repeat the same operation on the other conductor in order to complete the connection L Technical Data Conductive Material Aluminium 99.6% Pure Insulating Material Thermoplastic Polymer No of Crimps per end Colour 5 Grey 5 2 3 4 1 STRIPPING LENGTH 5 Violet Operating Temperature -55°C to 100°C Conformant Standards HN 33 S 66August 1985 EDF HN 33 E 60August 1988 EDF Accepting Authorities Electricity Services Victoria, Energy Australia and many other recognised authorities Pre-Insulated Bi-Metal ABC Lugs CABAC Bi-Metal Aerial Bundled Cable (ABC) style lugs are designed to connect ABC cables to transformers, switchgear etc on the pole top. They are pre-insulated so there is no requirement for insulation, heatshrink etc at the pole top. Features include: • Stripping lengths, die size, crimp number and sequence is moulded onto the lug insulation • Lugs are colour coded for identification of cable sizes • The end seal gives a 6kV under water dielectric strength • The lug is pre-filled with jointing compound for improved Electrical contact To install the lug, simply strip the ABC conductor to the strip length indicated on the insulated barrel, and crimp using a hydraulic tool. The CABAC HT51 crimp tool is specifically designed for this purpose, however any 13 tonne tool can be used Stud Tooling Size (mm) 12 Die A/F Hex (mm) 17.3 HT51, HT131-UC, RHC131, HT131-C, B131-C CatalogueDimensions Nominal Colour No. A D O Conductor Coding (mm) (mm2) BMABC50 95 8.512.2 50 Yellow BMABC95 114 12.516.0 95 Grey 12 21.5 BMABC150 114 15.518.75 150 Violet 12 21.5 Technical Data Material BarrelAluminium PalmCopper Conformant Standards AS4325, BS4579, IEC France, AS/NZS 4396:1996 Appendix D7.3 (Test) Weld Type Friction Weld J12 D 4 O 3 2 1 Stripping Length 5 A B Aluminium Sleeve - Overhead Line Aluminium Non-Tension Sleeve CABAC’s range of Non-Tension Sleeves are designed for use with AAC or AAAC conductors. They include a centre cable location dimple and are filled with jointing compound and have sealing caps on each end to retain the compound during transport and minimise oxidation. They can be crimped with hex or indent dies. AAC/AAAC AAC AAAC Conductor CatalogueConductor Conductor Conductor O.D. Crimp No. Stranding Name Name mm I.D. A Die A/F No. of Hex Die Crimps mm per end ANT36 7/2.25 Jupiter Boron 6.757.90 58 HT-50/70AL 13.2 7/2.50 Leo Chlorine 7.507.90 58 HT-50/70AL 13.2 1 ANT44 7/2.75 Leonids Chromium 8.25 9.60 70HT-7/300-375AL18.0 7/3.00 Libra Fluorine 9.00 9.60 70HT-7/300-375AL18.0 1 ANT50 7/3.75 ANT58 7/4.50 Mercury Hydrogen 13.5014.60 110 HT130-C-150 18.3 3 ANT61 7/4.75 Moon Iodine 14.25 15.00 110 HT-150/180 AL 22.0 2 ANT68 19/3.25 Neptune Krypton 16.25 17.00 146 HT-150/180 AL 22.0 3 ANT80 19/3.50 19/3.75 Orion Pluto 25.4 25.4 3 ANT94 37/3.00 37/3.25 19/4.75 Saturn Nitrogen 21.0024.59 155 HT-240/300AL 28.4 Sirius 22.7524.59 155 Taurus Oxygen 23.75 24.59 155ECW-H3D19/475 30.3 o’lap Triton Phosphorus 26.25 29.00 185ECW-H3D37/375 43.2 o’lap Mars 11.25 12.60 85 Lutetium 17.5020.20 146 Neon 18.7520.20 146 HT-16.8AL HT-A7 HT-A7 16.8 2 o’lap Centre Dimple I.D. A Aluminium Full Tension Sleeve - ‘A’ Style CABAC’s range of Full Tension ‘A’ style sleeves are designed for use with AAC or AAAC conductors under full tension loading. They include a centre cable location dimple and are filled with jointing compound. They can be crimped using hex or indent dies. AAC/AAAC AAC AAAC Conductor CatalogueConductor Conductor Conductor O.D. Crimp No. Stranding Name Name mm I.D. A Die A/F No. of Hex Die Crimps mm per end AFT36A 7/2.25 Jupiter Boron 6.757.90 165 HT-50/70AL 13.2 7/2.50 Leo Chlorine 7.507.90 165 HT-50/70AL 13.2 3 3 AFT44A 7/2.75 7/3.00 3 3 AFT50A 7/3.75 Leonids Chromium 8.25 9.60 165HT-7/300-375AL 18.0 Libra Fluorine 9.00 9.60 165HT-7/300-375AL 18.0 Mars Helium 11.2512.60 205 HT-16.8AL 16.8 6 AFT58A 7/4.50 Mercury Hydrogen 13.5014.60 205 HT130-C-150 18.3 4 AFT61A 7/4.75 Moon Iodine 14.25 15.00 240 HT-150/180 AL 22.0 6 AFT68A 19/3.25 Neptune Krypton 16.25 17.00 280 HT-150/180 AL 22.0 8 25.4 25.4 10 10 AFT80A 19/3.50 19/3.75 Orion Pluto AFT94A 37/3.00 37/3.25 19/4.75 Saturn Nitrogen 21.0024.59 380 HT-240/300AL - Sirius 22.7524.59 380 Taurus Oxygen 23.75 24.59 380 ECW-H3D19/475 40.0 10 o’lap AFT114A 37/3.75 Triton 15 o’lap Lutetium 17.5020.20 320 Neon 18.7520.20 320 Phosphorus 26.25 25.50 HT-A7 HT-A7 580 ECW-H3D37/375 43.2 ALUMINIUM SLEEVE - OVERHEAD LINE ANT114 37/3.75 Helium J13 Aluminium Sleeve - Overhead Line Aluminium Full -Tension Sleeve - R Style CABAC’s range of ‘R’ style O/H Sleeves are designed for full tension loads with ACSR. For strandings with a high steel content, please contact CABAC Engineering Department to validate the use. The sleeves include a centre dimple and are filled with a jointing compound. They should be crimped using hex crimps or ‘versa-crimp’ indent style crimping. ALUMINIUM SLEEVE - OVERHEAD LINE ACSR Conductor Catalogue Conductor Conductor O.D. Crimp No. Stranding Name mm I.D. A Die J14 A/F Hex Die mm No. of Crimps per end 14.0 14.0 8 8 AFT36R 6/1/2.50 3/4/2.50 Almond Raisin 7.50 7.50 9.11 9.11 355 355 AFT44R 6/1/2.75 6/1/3.00 4/3/3.00 Apricot Apple Sultana 8.25 9.00 9.00 11.12 11.12 11.12 355 HT-95/120AL 355 HT-95/120AL 355 HT-95/120AL 17.3 17.3 17.3 8 8 8 AFT50R 6/1/3.75 4/3/3.75 Banana Walnut 11.25 11.25 12.70 12.70 470 HT-95/120AL 470 HT-95/120AL 17.3 17.3 11 11 AFT58R 22.20 14.72 470 HT-7/300-375AL 18.0 11 AFT61R 6/4.75 7/1.60 Cherry HT-7/225AL HT-7/225AL 14.30 15.46 505 HT-150/185AL 22.0 OVERLAP AFT80R 30/7/2.50 Grape 17.50 20.21 580 24.9 OVERLAP AFT94R 30/7/3.00 Lemon 24.50 24.59 610 HT-240/300AL 34.5 OVERLAP L HT-24.9AL Insulating Covers, Mats & Tiger Tails® Temporary insulating items to assist in providing safe environment when working with Electrical equipment. Tiger Tails® (Torapoli Pipe) A high grade HDPE split tube pipe material. Industry standard pipe, with unique high visibility striped patterns. Eyelet in bell housing, interlocking male to female. Suitable as Electrical insulation PPE, mechanical protection and visual warning on power lines and conductors. •Industry Standard •Complies with & marked to AS4202 Class 1 •Maximum use 650V •High Visibility •High Electrical Insulation •Mechanically interlocks DB35A Tiger Tails®, Yellow/Black Stripe 2.5M Electrical Insulation Mat A high quality black, EPDM rubber insulation barrier used by network personnel & contractors as PPE to stand on when working around conductors in live voltage environments. Because of their relative light weight, these rubber insulation mats are used as portable temporary, on-site ground insulation as well as more static switchboard matting. The mats are made from a special flexible EPDM rubber which reduces the tendency of the mat to curl after being stored in a rolled position. •High Grade EPDM Rubber •High Electrical Resistance •Complies with & marked to AS2978 Class A •Maximum use 650V •Lightweight & flexible •Extreme weathering resistance •Non-slip & easy to clean •Dimensions: 1000 x 1000 x 6mm 6EPDM1000LV Electrical Insulation Mat Insulating Line Covers A high quality, dual layer PVC insulation barrier used by network personnel & contractors as PPE to cover and drape over live conductors and power lines in low voltage environments. INSULATING COVERS, MATS & TIGER TAILS ® •Resistant to many chemicals •Light weight, reliable and durable • UV stabilised •Complies with & marked to AS4202 Class 2 •Maximum use 650V •Strong physical properties LSC225 Electrical Insulation Cover 1200 X 225mm LSC300 Electrical Insulation Cover 1200 X 300mm LSC375 Electrical Insulation Cover 1200 X 375mm J15 Flexible Copper Braids CABAC Flexible Copper Braids are an extremely flexible lead, which are typically used on disconnects and switch handle grounds. They can also be used to take up linear expansion and contraction, or absorb vibration. • Seamless pure copper ferrules are formed into a rectangular shape on each end • Standard braids are supplied with tinned braid, and plated ferrules • Single or double hole available as standard • Special ends and braid types are available on request • Note the “length” of the braid is between centre of the first holes Shown below is our standard range, specials can be made up on request. To assist quotation, please photocopy the diagram on the facing page, fill in the details and fax to CABAC sales. Catalogue No. Amp Rating (Approx) No. of Length Width Ferrule Spacing Ferrule L W A B Holes Dimensions (mm) Stud Hole No. of Braids Single Hole Version CAB100A-300M12 10013002225 – 131 FLEXIBLE COPPER BRAIDS CAB300A-300M12 30013002536 – 132 CAB450A-300M12 45013003036 – 133 CAB600A-300M12 60013003540 – 134 Two Hole Version CAB100A-300M12X2 1002300225025131 CAB300A-300M12X2 3002300256030132 CAB450A-300M12X2 4502300306030133 CAB600A-300M12X2 6002300357035134 Note: The amperage rating is nominal, and depends on environment, for example indoor or outdoor. Consult with CABAC engineering if unsure. Generally indoor de-rate nominal rating by 20%. Braid length between holes (L) Hole Size W Two Hole Ferrule Single Hole Ferrule A B A Part numbers are made up according to the following legend: Amperage Length between first holes (mm) Stud Size (mm) – hole will be clearance No. of holes Typical Part No: CAB 300A – 600 M12 X2 J16 Single Braid Twin Braid Braid Details - Special Manufacture Order Number: Date: Customer Contact: CABAC Contact: Company: Name: Contact: Phone: Phone: Fax: Fax: Mobile: Date Delivery Required Qty Required Note: Hole size needs to be 0.5 to 1mm more than stud size ONE HOLE mm mm (Nominate Stud) mm Note: Any customer specific product will be given a part number by CABAC, specific to the customer/drawing. This dimension will depend on Amperage rating see standard range mm TWO HOLE THREE HOLE mm Length mm Length mm mm mm BRAID DETAILS - SPECIAL MANUFACTURE Part Number: mm mm SPECIALLY MANUFACTURED GOODS ARE NOT RETURNABLE FOR CREDIT Customer Approval: Date: FAX THIS FORM BACK TO CABAC MANUFACTURING FAX: 1300 303 310 J17 Cable Pits & Lids Cable Pits & Lids Catalogue Description No External Dimensions L x W x D mm P1PIT Plastic Cable Pit; Size P1 P1LIDC LID P1PIT, concrete: Commcab P1LIDE LID P1PIT, concrete: Electrical P1LID-GS-BLC LID:Galvanised steel, Commcab P1LID-GS-BLE LID:Galvanised steel, Electrical P1LID-GS-LOCKC LID: galvanised with locking device, Commcab P1LID-GS-LOCKE LID: galvanised with locking device, Electrical P2PIT-B Plastic Cable Pit; Size P2 P2LIDC LID P2PIT, concrete: Commcab P2LIDE LID P2PIT, concrete: Electrical P2LID-GS-BLC LID P2PIT, galvanised steel, Commcab P2LID-GS-BLE LID P2PIT, galvanised steel, Electrical P2LID-GS-LOCKC LID P2PIT, galvanised with locking device, Commcab P2LID-GS-LOCKE LID P2PIT, galvanised with locking device, Electrical P3PIT-B Plastic Cable Pit; Size P3 P3LIDC LID P3PIT, concrete: Commcab P3LIDE LID P3PIT, concrete: Electrical P3LID-GS-BLC LID P3PIT, galvanised steel, Commcab P3LID-GS-BLE LID P3PIT, galvanised steel, Electrical P3LID-GS-LOCKC LID P3PIT, galvanised with locking device, Commcab P3LID-GS-LOCKE LID P3PIT, galvanised with locking device, Electrical P4PIT-B Plastic Cable Pit; Size P4 P4LIDC LID P4PIT, concrete: Commcab P4LIDE LID P4PIT, concrete: Electrical P4LID-GS-BLC LID P4PIT:Galvanised steel, Commcab P4LID-GS-BLE LID P4PIT:Galvanised steel, Electrical P4LID-GS-LOCKC LID P4PIT: galvanised with locking device, Commcab P4LID-GS-LOCKE LID P4PIT: galvanised with locking device, Electrical P5PIT Plastic Cable Pit; Size P5 P5-800 PIT P5PIT-800: 600 x 350 x 800 P5LIDC LID P5PIT, concrete: Commcab P5LIDE LID P5PIT, concrete: Electrical P5LID-GS-BLC LID P5PIT, galvanised steel, Commcab P5LID-GS-BLE LID P5PIT, galvanised steel, Electrical P5LID-GS-LOCKC LID P5PIT, galvanised with locking device, Commcab P5LID-GS-LOCKE LID P5PIT, galvanised with locking device, Electrical Weight kg 520 x 230 x 410 470 x 195 470 x 195 470 x 195 470 x 196 470 x 194 470 x 195 4.57 8 8 5 5 7.26 7.26 665 x 285 x 570 615 x 245 615 x 245 615 x 245 615 x 246 615 x 244 615 x 245 5.7 13.9 13.9 9.2 9.5 9.79 9.79 780 x 350 x 585 730 x 300 730 x 300 730 x 300 730 x 301 730 x 299 730 x 300 7.98 25 25 13 13 14.2 14.2 705 x 405 x 830 730 x 300 730 x 300 730 x 300 730 x 301 730 x 299 730 x 300 9.44 27 27 15 15 14.21 14.21 705 x 450 x 660 705 x 450 x 830 12.21 16 650 x 400 650 x 400 650 x 400 650 x 401 650 x 399 650 x 400 30 30 16.9 16.9 18.9 18.9 P1 Plastic Pit with Concrete Cover P2 Plastic Pit with Concrete Cover P1-3 Plastic Pits P4 Plastic Pit with Concrete Cover P5 Plastic Pit with Concrete Cover Cable Pits & Lids Accessories Catalogue Description No T-BEAM6-8-9 T-BEAM7 T-Bar Suit Pit 6,8 & 9 (P9 Requires 2 Of) T-Bar Suit P7 pit Pits with 2 lids require T-BEAM support Pits with 3 lids require two T-BEAM support J18 External Dimensions Length 496 496 Weight kg T-Beam 6-8-9 2.65 3.83 T-Beam7 Cable Pits & Lids Cable Pits & Lids Catalogue Description No ExternalWeight Dimensions kg L x W x Dmm P6PIT P6LIDC# P6LIDE# P6LID-GS-BL-HFC P6LID-GS-BL-HFE Plastic Cable Pit; Size P6 1360 x 555 x 660 LID P6PIT, concrete: Commcab (2 Per pit required) 650 x 500 LID P6PIT, concrete: Electrical (2 Per pit required) 650 x 500 LID P6PIT, galvanised steel: Commcab (2 Per pit required) 650 x 499 LID P6PIT, galvanised steel: Electrical (2 Per pit required) 650 x 500 P7PIT P7LIDC# P7LIDE# P7LID-GS-BL-HFC P7LID-GS-BL-HFE Plastic Cable Pit; Size P7 1040 x 555 x 1125 41 P6 Plastic Pit with Concrete Cover and Crossbar LID P7PIT, concrete: Commcab (2 Per pit required) 490 x 460 29 LID P7PIT, concrete: Electrical (2 Per pit required) 490 x 460 29 LID Galvanised steel: Commcab (2 Per pit required) 495 x 477 15.27 LID Galvanised steel: Electrical (2 Per pit required) 495 x 478 15.27 P8PIT* P8PIT-TEL P6LIDC# P6LIDE# P6LID-GS-BL-HFC P6LID-GS-BL-HFE Plastic Cable Pit; Size P8 TYPE 8 PLASTIC PIT (OPTUS) LID P6PIT, concrete: Commcab (2 Per pit required) LID P6PIT, concrete: Electrical (2 Per pit required) LID Galvanised steel: Commcab (2 Per pit required) LID Galvanised steel: Electrical (2 Per pit required) 1360 x 555 x 860 1375 x 630 x 900 650 x 500 650 x 500 650 x 499 650 x 500 51 54 38 38 19.6 19.6 P9PIT Plastic Cable Pit; Size P9 2040 x 585 x 900 90 P6LIDC*# P6LIDE*# P6LID-GS-BL-HFC P6LID-GS-BL-HFE LID P6PIT, concrete: Commcab (3 Per pit required) LID P6PIT, concrete: Electrical (3 Per pit required) LID Galvanised steel: Commcab (3 Per pit required) LID Galvanised steel: Electrical (3 Per pit required) 650 x 500 650 x 501 650 x 501 650 x 502 38 38 19.6 19.6 P44PIT Plastic Cable Pit; SERIES 450 450 x 450 x 450 - P44LIDE P44LIDC LID P450PIT, concrete; heavy duty Electrical LID P450PIT, concrete; heavy duty Commcab 520 x 520 x 50 520 x 520 x 50 32 32 P66PIT Plastic Cable Pit; SERIES 600 600 x 600 x 600 14 P66LIDE P66LIDE LID P600PIT, concrete; heavy duty Electrical LID P600PIT, concrete; heavy duty Commcab 660 x 660 x 50 660 x 660 x 50 54 54 37 38 38 19.6 19.6 P7 Plastic Pit P44PIT Cable Pits & Lids Accessories - Rises/Collar Catalogue Description No P4Collar P5Collar P6Collar P7Collar Extension Collar (Riser) For P4pit - Plastic Extension Collar (Riser) For P5pit - Plastic Extension Collar (Riser) For P6 & P8 Pit - Plastic Extension Collar (Riser) For P7pit - Plastic External Dimensions Weight L x W x D mm kg 710 x 410 x 234 715 x 455 x 230 1380 x 545 x 280 1015 x 560 x 280 4.1 5.3 11.2 9.8 P7 Collar *Item is a non stocked item. Order as required. Delivery approx. 5-6 weeks. # Note: Required T-Beam Support. J19 Pit Keys & Breakers Telstra Approved Pit Keys MSS-TEL116-00152 - 600mm long MSS-TEL116-00153 - 670mm long Pit Lid Seal Breaker For use with Telstra pit keys. MSS-PB-100 Long Handle Gattic Lid Lifter MSS-GAT-LONG D Shape Gattic Lid Breaker MSS-GAT-SMALL Keyhole Plug Extractor Tool MSS-TEL075-00122 Cover Seal Breaker MSS-TEL116-00151A J20 Standard Pillar Tops & Bases Standard Pillar Box The CABAC Pillar Box is a quality, cost effective distribution cover that accommodates all standard underground cable reticulation requirements. These pillars have been in service for a number of years, installed by the power authorities. • Fit existing bases - standard bolt pattern and dimensions • A bottom venting channel allowing the free flow of air while obstructing any water or foreign bodies • Optional top venting for exhausting hot air in order to maintain lower operating temperatures for internal fuses, links, etc • This design incorporates a baffle system to condense humid air and divert water condensation outside • Standard covers are embossed with ‘Danger Electricity’ on top • Standard colour is nature green. Beige and special colour on request • Recyclable material • These pillars can be stacked to reduce storage costs Beige Pillar Box - Large Green Pillar Box - Short C • All sizes of tops and bases are interchangeable with standard and large range Standard production material is ultra-violet stabilised to LS3 with proven long life exposure to sunlight. This material offers high absorption to everyday impacts with equally high resistance to contaminants, while presenting a rigid cover free from distortion. Top elevation Front view Side view Catalogue Cabac Superseded No. Part Code Description Pillar Boxes A PBL-G-NV-SD PBL PBL-KIT PBL-G-V PBLV PBL-KITV Pillar top long no vent Pillar top long no vent, base & D-bolt Kit 545290222315248320282 Pillar top long vented Pillar top long vented, base & D-bolt Kit PBS-G-NV-SD PBS PBS-KIT PBS-G-V PBSV PBS-KITV Pillar top short no vent Pillar top short no vent, base & D-bolt Kit 315290232315248320282 Pillar top short vented Pillar top short vented, base & D-bolt Kit PBL-B-NV-SD PBL-B-KIT PBL-B-V PBL-B-KITV Beige Pillar Boxes Pillar top long no vent Pillar top long no vent, base & D-bolt Kit 545290222315248320282 Pillar top long vented Pillar top long vented, base & D-bolt Kit PBS-B-NV-SD PBS-B-KIT PBS-B-V-SD PBS-B-KITV Pillar top short no vent Pillar top short no vent, base & D-bolt Kit 315290232315248320282 Pillar top short vented Pillar top short vented, base & D-bolt Kit B Dimensions C D E F G Tops & bases are available in other colours on request: orange, blue & grey. Special flame retardant and high impact materials are available on request. J21 Standard Pillar Bases Standard Pillar Base The CABAC Pillar Box Base is an all-purpose moulded plastic base to suit direct burial or slab mounting. The base can be directly buried, or bolted to a slab. For high stability on steep slopes or unstable soils the base can be attached to a steel framework and stabilised soil/concrete poured around the base. Frame available on request. • The base is light for ease of handling, transport and storage • Slots for four standard fuse panels or one large panel • Wide skirt for increased stability • Upturned skirt lip increases resistance to pull out - dosing effect • Flat bottom for slab mounting – dyna holes included • Corrosion-proof brass inserts for cover bolts • Wall design allows drilling for side entry • Able to be stacked to reduce storage costs • A datum line is provided to indicate burial depth • All sizes of tops and bases are interchangeable with standard and large range Catalogue No. Cabac Superseded Part Code Description A PBB-G-IM-SDI B C D E F G PBB-G-IM-SDI PBB PBB-B-IM-SDI Pillar box base green with brass insert Pillar box base beige with brass insert 355 557524 362329253170 SBK-G-IM-SDK Split Pillar base kit green 355 557 524 362 329 253 170 PBB-G-IM-BBK Kit - Button Bolts + PBB-G-IM-SDI PBB-G-IM-CWK Kit - D Bolts + PBB-G-IM-SDI Technical Data Material Polypropylene copolymer with additive rubberiser Thermal Conductivity 0.121 W/mk at 23°C Thermal Coefficient of Linear Expansion 86°C -1 x 10° Flame Retardancy 750°C min (AS2420 App B) Wall Thickness 4mm min Yield Tensile Strength 24 MPa min (ASTM D638-77A at 23°C) Vicat Softening Point 143°C (ASTM1526) Izod Notch Impact 500 J/m min (ASTM D256 at 23°C) Melt Flow Index 1.5 g/10 min (ASTM1238 Condition E) IP Rating IP44 (Attached to CABAC base) J22 SBK-G-IM-SDK Standard Pillar Base PBB-B-IM-SDI Extra Large Pillar Top & Base Large Pillar Box High Capacity - NEW INNOVATIVE CONCEPT • New Innovative concept • New pillar design fits existing bases - standard bolt pattern and dimensions • Additional 25.7% internal capacity • CABAC registered design • All sizes of tops and bases are interchangeable with standard and large range Catalogue KULAK No. Superseded Part No. Description A B C D E F G Pillar box high capacity 555 PBHCV vented 311 269 340 298 PBBL PBB-G-INSW 557 524 359 326 287 224 Pillar box base green to suit PBHCV 344 320 282 FPB Fuse Panel Block (pair) to fit series PBFP fuse panels to PBBL PBBL-G-I-CWK Kit - D Bolts + PBBL PBBL-G-I-BBK Kit - Button Bolts + PBBL 25% EXTRA VOLUME PBHCV REGISTERED DESIGN FBP PPBL with FBP in place J23 Extra Large Pillar Top & Base LACKING CAPACITY CABAC’s extra large tops & bases allow for increased work space and is interchangeable with standard tops & bases. “Danger Electricity” Embossed on top Air Flow Vent Holes (Optional) Covered by Rain Baffle 25% Rain Baffle EXTRA VOLUME CABAC’s CMPBL2 Patented Bimetal Bolted URD Connection System (Space Saving URD) Neutral Service Supply Phase Service Supply Neutral Bar For Service Connectors Mains Cable 240mm2 sector Aluminium Fuse Panel For Service Supply (Optional use depends of local utility requirement) PBHCV Extra Large Top Heavy Duty REGISTERED DESIGN Bolts available in Allen Key head, D Bolt or locking bolt type PBBL Extra Large Base (No increase in outside dimensions) Air Flow Air Flow Stainless Steel Allen Head Bolt Vent Slots J24 U’ground Residential Distribution Bolts for Pillar Box Assembly CABAC has two bolt styles for the pillar boxes: allen head bolt and ‘D’ bolt style to deter unauthorised entry. The bolts are made from stainless steel with options of washers and o-rings. Allen head bolts require a conventional 6mm allen key driver. PBLB The ‘D’ bolts require a special tube spanner which has a long handle to clear the top of the pillar box, so that the bolts can be tightened or loosened without the risk of the spanner fouling the pillar box. CABAC has introduced a handy cordless drill socket drive for ‘D’ bolts. This speeds up cover removal and replacement. Part number D-SOCKET. An innovative locking bolt (PBLB) is made to order to prevent unauthorised entry using a padlock. DBI-SS-10-30 M10X30BBOLT DB-TBSS Allen Head D Bolt D-SOCKET Catalogue Cabac Superseded Description No. Part Code M10X-SS304-BUTTSCR Allen head bolt no washer A B Thread 30 10 M10 M10X30BBOLT Allen head bolt with washer 30 10 M10 Allen head bolt with washer set of 4 30 10 M10 BUTM10K PBAB DBI-SS-10-30 ‘D’ head bolt with washer 30 10 M10 DBI-SS-10-70 ‘D’ head bolt with washer & o-ring 70 10 M10 DBI-SS-10-30K PBDB1W ‘D’ head bolt set of 4 30 10 M10 PBLB DB-TBSS D-SOCKET PCB-AL-80-48 PBTS CADBS Locking bolt-special order M10 ‘D’ bolt ‘T’ bar socket spanner ‘D’ bolt cordless drill socket drive for ‘D’ bolts Alum phase connection bar Labels ARROW-HV-LGE - Arrow HV Large - L116 x W78mm ARROW-LV-LGE - Arrow LV Large - L116 x W78mm ARROW-HV-SML - Arrow HV Small- L78 x W78mm ARROW-LV-SML - Arrow LV Small - L78 x W78mm EKERB - Bronze E Kerb Marker - Ø34.5mm WKERB - Bronze W Kerb Marker - Ø34.5mm TKERB - Bronze T Kerb Marker - Ø34.5mm TKERB ARROW-HV-LGE WKERB EKERB ARROW-LV-LGE Brass Label UCM-1 - “Danger Underground Electric Cables” brass label for mounting in concrete L145 x W48 x D6.2.2mm J25 U’ground Residential Distribution Fuse Panels CABAC can supply any Fuse Panel design required. Since designs vary substantially, we stock a few standard undrilled fuse panels from which we are able to manufacture any design that may be required. They have tapered corners that fit into slots on the base to keep the panels secure and are compatible with existing installations. Common panels are injection moulded from Electrical grade thermoplastic material and less common ones are made from resin impregnated fibre board, switch grade board. Catalogue No. FPS-BK-UN-BL Cabac Superseded Number Part Code of Fuses PBFP-190 3 FitsDimensions (mm) Pillar A B C All 190205 8 Material Thermoplastic PBFP-240 - All 240 FPM-BK-UN-BL PBFP-280 6 All 280205 8 Thermoplastic 285 285 10 Resin impregnated board 390 205 10 Resin impregnated board 495 205 10 Resin impregnated board FPMW-BK-UN-BL PBFP-390 FPL-BK-UN-BL PBFP-495 PBFP-540 FPLW-BK-UN-BL - - Large vented 9 and unvented 12 205 10 Resin impregnated board - Large unvented only 540 283 10 Resin impregnated board - - 495 285 10 Resin impregnated board C Fuse Panels Accessories Catalogue No. FPC-SW-VC-SD Cabac Superseded Part Code PBFPSC NLA-1L-SQ Description Fuse panel securing clips Neutral link 5 hole 16mm lug A S7125BWQ12A meter link - clear S7QLD2AFW 100A front wired fuse base & carrier ALS240/4-12 Cable lug suit 240mm2 FPB Fuse Panel Block to fit fuse panels to PBBL locating holes for fus e panel clips B 3 Fuse Panel Fitted with: 3 x 100A Fuse Holders 1 x 5 Hole Neutral Link Fuse Panels Assemblies Catalogue Cabac Superseded No. Part Code 1F-MPS-AS-SQ Description 2F-MPS-AS-SQ 2 Fuse panel assembly 3F-MPS-AS-SQ 3 Fuse panel assembly 4F-MPM-AS-SQ 4 Fuse panel assembly 5F-MPM-AS-SQ 5 Fuse panel assembly 6F-MPM-AS-SQ 6 Fuse panel assembly 1 Fuse panel assembly A B 6 Fuse Panel Fitted with: 6 x 100A Fuse Holders 1 x 5 Hole Neutral Link J26 C U’ground Residential Distribution Shrouds CABAC’s Shrouds are designed to fit over the bolted lug connections inside a pillar box so that they insulate the live connections in the event that the pillar box is lifted off. They are made from flame retardant PVC which is flexible enough to reshape around the bolted connectors that they enclose. The shrouds have two holes near the open end so that they can be fixed in position using a cable tie. Technical Data Material PVC Compound Voltage Rating 1 kV Thickness 2mm min Flammability Non Ignitable (AS 2420 App.B) ISP-BK-SM-FT Catalogue No. ISP-BK-SM-FT-NH Cabac Superseded Part Code ISP-BK-SM-FT-NH ISP-BK-SM-NH Description Dia Length Overall Length Shroud Small Flat Top 65mm ID - no hole 65 95 100 Shroud Small Conical 65mm ID - no hole 65 85 138 S66 Shroud Small Conical 65mm ID - 5mm hole 65 85 138 Shroud Small Flat Top 65mm ID - 5mm hole 65 95 100 ISP-BK-SM-8MM Shroud Large Conical 65mm ID - 8mm hole 65 85 138 ISP-BK-LG-FT-NH Shroud Large Flat Top 65mm ID - no hole 91 155 160 ISP-BK-SM-5MM ISP-BK-SM-FT ISP-BK-LG-NH ISP-BK-SM-5mm Shroud Large Conical 95mm ID - no hole 91 150 195 S90 Shroud Large Conical 95mm ID - 5mm hole 91 150 195 ISP-BK-LG-FT Shroud Large Flat Top 95mm ID - 5mm hole 91 155 160 ISP-BK-LG-8MM Shroud Large Conical 95mm ID - 8mm hole 91 150 195 ISP-BK-LG-5MM Pole Top Cover CAP350 - Pole cover top. Aluminium disc for covering wood pole tops. Ø350mm. J27 URD Connection System with Crimp Lugs for Mains Pillar URD Connection System - Crimp Lugs The CABAC crimp type URD system is a standard component kit using standard 240mm2 aluminium lugs for mains cables and copper lugs for service cables. The lugs are crimped to their respective cables and fastened to a busbar by stainless steel bolts. M12WSST Steel Washer Heatshrink sleeves are shrunk over the cable ends to insulate the lug barrels and a heatshrink end cap is shrunk over the whole connection to give an insulated and weather sealed termination. M12SSN M12 Nut Cabac URD terminal blocks (optional extra) are used to connect to the copper service cables tails and from these terminals house services can be tapped off. The kits are suitable for one pillar with mains cables for three phases and a neutral. The kits are available in three configurations, that is, a single mains cable end, a two mains cables per phase and a three mains cables per phase terminations. The kits come with all items an installer will need to make the mains and T-off connections. Terminal blocks are an optional extra. Serviceable Cable 25m2 - 50m2 (70m2 for CMP1) Mains Cable (240mm2 for Aluminium) Heatshrink Cap SRE6U-Long (for CMP2) or SRE4U-Long (for CMP1) CatalogueDescription No CMP1 Single Cable Pillar Kit 1 CMP2 Double Cable Pillar Kit 2 CMP3 Triple Cable Pillar Kit 3 Heatshrink Cap NB: These parts are made to order. Busbars for URD assemblies Catalogue No L WH PCB-AL-80-482hole 80 40 6.1 ABB7640 Aluminium Lug 2hole 76 4010 Main Pillar (Top) See page Ua44 Heatshrink Sleeve Terminal Blocks See page U30 Service Cable Tail 250 Service Cable Mains Cable Pillar Base 50 75 Earth Cable Mains Cable Shear J28 M12BSST-40 M12 Steel Bolt Ground Level Service Cable Shear XLP20YG or XLP37BK Heatshrink Sleeve ABB7640 Basbar for CMP2&3 URD Connection System - Bolted FOR STRANDED, SOLID SECTOR CABLES AND CIRCULAR STRANDED The CABAC URD Connection is designed to make looped pillar connection systems quick and easy, by eliminating many of the components and the tedious crimping needs of current practices. • The heart of the system is a patented lug of unique design, that is both range taking and multiple cable acceptable • The connection principle is via proven shear head technology eliminating the need for crimping tools, dies and the attendant operator skills necessary for good connection • The unique palm incorporates an inbuilt terminal block offering a series of range taking tunnels 6 (in the case of looped pillars) with a maximum capacity of 50mm2 • To create the loop, connectors are bolted back to back, using two or three way bus bars which allow branch off connections to be made with ease • The connector system is a true bi-metal system with the lug manufactured from high grade Electrical aluminium which is then copper plated and tin plated finally to produce a connector for use with both copper and aluminium cables • The installation is simplicity in itself requiring only a small number of hand tools, Allen keys for shear bolts and cable connection, Spanners to connect the bus bar and a screwdriver to complete the cover • The system has been extensively tested and meets fully the requirements of AS4325 for both stranded and solid conductors • The covers meet finger safe concepts and the requirements for a 1000 volt proof cover The cover is manufactured from glass filled nylon providing an extremely tough and durable cover system Catalogue Conductor Shear Head Terminal No. (mm2)Bolts Block Service & Lugs LUG – 1, 2, 3 WAY Blank Lugs (3 Way Kit) BALURD95 BALURD95-2 95 6mm Allen key5mm Allen key BALURD120 BALURD120-2 95 6mm Allen key5mm Allen key BALURD185 BALURD185-2 95 6mm Allen key5mm Allen key BALURD240 BALURD240-2 95 6mm Allen key5mm Allen key Cross road cable connection if required Tunnel for neutral or cross road connection ONE WAY NB: Blank lugs do not have service tunnels. Bus Bar ABBCMP1* Single hole bus bar to bolt 2 lugs back to back ABBCMP2* Double hole bus bar to bolt 3 or 4 lugs back to back KITS* CMPBL1 CMPBL2 CMPBL3 URD Pillar 1 Way Pillar Kit 2 Way Pillar Kit 3 Way Pillar Kit Service Cable Connections Service cables Shear heads Incoming 4 core 240mm Aluminium sector cable Technical Data - Please refer to page B33. *These parts are made to order. THREE WAY TWO WAY Cross road cable connection if required Tunnel for neutral or cross road connection Grub Screws Bus bar Stainless steel bolt and nut bevilled washer Bus bar Stainless steel bolt and nut bevilled washer Bus bar Stainless steel bolt and nut bevilled washer Cross road cable connection if required Bolted lugs Bolted lugs Grub Screws Service Cable Phase and Neutral Arrangement Shear heads Rear lug has no tunnels Phase and Neutral Arrangement Shear heads Service cables Incoming 4 core 240mm Aluminium sector cable Mains Cables Incoming 4 core Aluminium sector cable Mains Cables J29 URD Connection System - Covers The unique CABAC URD Cover system has been designed specifically to compliment the URD Bolted lugs and provide a simple and easily installed connection cover. • Three covers are available to contain either single, looped or 3 way arrangements • Each phase is terminated separately within its own cover a design feature that eliminates the need to tailor more than a maximum of 3 cables at any one time • The cover is completely reversible and has an inbuilt tolerance to accept some degree of misalignment of the connectors should a difficult installation exist • The cover system is Electrically safe and is of the required finger proof concept. Fully tested the cover meets 1000 volt safety security. Manufactured from glass filled nylon, the cover is capable of withstanding very high impact loads to provide an almost indestructible protection device • The covers cable ports are accessed from the front cover where the following ports are available 4 cable ports for a maximum of 25 mm2 cable. 2 cable ports for a maximum of 50 mm2 cable • The cover has been designed to hold the cable connection grub screws and prevent their dislodgement into the junction box cover • Strip length information for cables is clearly marked on the junction box cover • Should it be necessary, live services can be safely installed by the use of insulated allen keys CatalogueDescription No. URDCL1 Single Cable Bolted Lug Cover URDCL2 Double Cable Bolted Lug Cover URDCL3 Triple Cable Bolted Lug Cover Technical Data - Please refer to page B29. URD KIT URD Installation Kit Please refer to section G - Tools. URD KIT 2 WAY J30 3 WAY URDCL2 URDCL1 URDCL3 URD Connections Terminal Block up to 50mm2 CABAC’s TB503 and TB506 terminal blocks are designed to connect power conductors up to 50mm2. The primary use is in URD pillars, when consumers mains connections have to be made. TB503A has 3 terminals used for conductor up to 16mm2 and 2 terminals in the rear for conductor up to 6mm2. The rear 2 terminals are used for street lightning. • Three and six way configurations for conductors up to 50mm2 • The six way block has a touch proof blanking insert to protect against accidental electrocution • Shrouded allen key screws for clamping the conductor • Two allen screws per conductor for extra security TB503 To install simply strip the conductor insert, and tighten the allen screws. TB503 3 Way TB503A 3 Way (2-6mm Cable Tunnels For Lighting Conductors) TB503B 3 Way Terminal Block 16mm + 2 Front 6mm TB506 6 Way TB506 2 2 TB503A Top View Technical Data Conductive Material Brass alloy tinned Set Screw Material Brass alloy tinned Cover MaterialPolycarbonate Accepting Authorities Energy Australia Integral Energy TB503B Rear View TB503A Rear View TB503B Top View Screen Wire Lug & Link These lugs and links are specifically designed to connect the screen wire in an underground joint. They use a simple shear head bolt up connection. • They are range taking, accommodating from 10mm2 to 50mm2 • They will accommodate both fine strands and building wire • Domed bolt ends, compress the conductor, and do not cut strands • The bolts have a shear head, which shears once the correct torque is achieved • The bolt threads are made using a special roll forming process to create threads that will not bind • They are made of tin plated brass, and as such can be used for copper or aluminium conductors 10.50 To install simply strip the conductors and torque up the bolts until the head shears. 16.00 20.00 SWL10-50Lug SWC10-50Link 39.00 SWL10-50 Technical Data Conductive Material Brass alloy tinned Set Screw Material Brass alloy tinned 16.00 10.50 40.00 14.00 SWC10-50 J31 Earth Rods - Copper Plated Steel CABAC Earth Rods are made from high quality carbon steel and copper plated to 250 micron. They are threaded on the flat top end and tappered on the other. Driving heads and couplers are available to increase penetration. A coupler is used to connect two or more rods together with one side threaded and the other an interference fit. A number of accessories are available to improve earthing ground connection and boxes to protect any protruding ends. CER15-HDH CER15-DH CER15-ECL TOPEARTH Catalogue No RODS CER15-1440 Description Weight ea. Copper Earth Rod Nominal Dia 15mm x 1.5m 1.92 kg CER15-1800 Copper Earth Rod Nominal Dia 15mm x 1.8m 2.3 kg CLAMPS CER15-EC Earth Clips to suit CER15 Cu Earth Rods N/A CER15-ECL Earth Rod clamp to suit CER15 Cu Earth Rod N/A COUPLERS AND DRIVING HEADS CER15-JC Jointing couplers to suit CER15 Cu Earth Rods N/A CER15-DH Driving head to suit CER15 Cu Earth Rods N/A CER15-HDH Hard Driving Head to suit CER15 Cu Earth Rods N/A EARTH CONNECTION ENHANCER TOPEARTH Bentonite/Gypsum Enhancement Material 20kg ERB2 ERB3 CONNECTION BOXES ERB2 ERB3 J32 Earth Rod Conn Box Polycrete Aluminium Checkered Lid 200 x 220 x 150mm Earth Rod Conn Box Polycrete 200 x 220 x 150mm CER15-1440 HV Equipment Portable Earthing Devices - HV Earthing Set for OH Lines or Switchboard Designing your ped set STEP 1: Choose Your Cable Size Cable Cross Section / Max Short Circuit Current (@ 0.5sec) 16mm2 / 4,500A 25mm2 / 7,000A 35mm2 / 10,000A 50mm2 / 14,000A 70mm2 / 19,500A 95mm2 / 26,500A 120mm2 / 33,500A 150mm2 / 42,000A NEW STEP 2: Choose Your Clamp Type Ball / Universal / OH Line STEP 3: Choose Your Cable Lengths Standard Switchboard earths are 600mm (A/B/C) and 1800mm (Earth) Standard Overhead earths are 2000mm (A/B/C) and 7000mm (Earth) Cable lengths can be tailored to suit your needs. D-750822 Custom Set Pre-made sets D-770604 Switch Board Earth Set 70/35 mm² D-795604 Switch Board Earth Set 95/35 D-712604 Portable Switch Board Earth Set 120/50 D-770604-S OverHead Earth Set 70/35 D-795604-S OverHead Earth Set 95/35 D-712604-S OverHead Earth Set 120/50 mm² Accessories - Attachment Points and Tools for PEDs D-755225 Straight Ball Joint with threaded shaft & nut D-755200 Straight Ball Joint with female thread (for bolt) D-754200 Fixed Ball Point 20mm/M12 (F) D-754235 Fixed Ball Point 20mm, 12x35mm D-756300 Angled Ball Joint with Hole D-761011 1m Insul Rod for fitting PED’s D-761016 Insulated Attachment Pole 1.5m D-769500 Telescopic Insulated Attachment Pole 5.5m D-772321 Clamp for Ball and Pin D-25mm D-772331 Clamp for Ball and Pin D-20mm D-773330 Clamp Universal up to D30mm D-773331 Uni clamp T-pin shaft long D-784085 Clamp for OH Cable D10-85mm D-785930 Deltec Wet Cleaner 33 KV D-785100 Deltec Vac Cleaner -HV 33 KV D-785502 LV Vac Cleaner attachments 1KV D-755225 D-756300 NEW D-755200 Ball Clamp Universal Clamp D-761016 OH Clamp J33 Copper ‘C’ Connectors The Copper ‘C’ Connector range is specifically designed for applications requiring corrosion resistant and high current jointing or tapping of buried copper earthing grids, or to earth rods. The range is dimensionally identical to the normally accepted dimensions in the Australian market. The crimp dies for the ‘C’ Connectors are oval in shape. CABAC’s ‘C’ Connectors are made from 99.9%+ cu high conductivity copper. The ‘C’ shape is coated with jointing compound and these connectors are individually packed in plastic bags. The connectors are supplied pre-loaded with jointing compound. CAEC Range - Tap Off ‘C’ Connectors These Tap Off Style ‘C’ Connectors are specifically designed to take a tap of 1.5 to 120mm2 from a run or to joint to 13 to 15mm diameter earth rod. The resultant joint is tamper proof and highly corrosion resistant, and can be directly buried. The ‘C’ connector is crimped using dies and a standard 13 tonne tool - our HT131-C. Conductor/Earth Rod Range Catalogue Conductor mm2 Tap OffDimensions (mm) Crimp B C Tooling Die No. or Earth Rod Dia. mm (rmm2) A CAEC1.5 1.5 53.023.02.00 CAEC2.5 2.5 53.023.02.50 CAEC4 4 53.023.03.00 25 53.023.07.50 CAEC70 70 53.0 23.011.50 35 53.023.08.50 50 53.023.09.50 CAEC95 95 53.0 23.013.50 CAEC120 120 53.0 23.015.50 ECW-H3D 16 53.023.05.50 CAEC25 13, 14 or 15mm diameter CAEC35 earth rod CAEC50 MSS-C120-42-18V CAEC16 6 53.023.03.50 RHC131, RHU131-C 10 53.023.04.50 HT131-C, HT131-UC, B131-C CAEC6 50 to120mm conductor CAEC10 2 HT-CAEC C A Rod B J34 Cable ‘C’ Connectors This range is used for joining and tapping conductors. The smaller ‘C‘ Connectors are used to connect 16, 25 and 35mm2 conductors, usually in distribution earth situations, and the larger connectors are primarily used to connect earth grids, the resultant joints being corrosion resistant and suitable for direct burial. Technical Data Accepting Authorities Rail Services Australia Australia’s major telecommunication authority Conductive Material Copper 99.95% pure Tensile Strength 200 MPa Ductile Rating 40% Conformant Standards International Standard (Heat Cycling Test) ESI 43/92 Operating Temperature -55°C to 155°C General Electrical Properties Total Conductivity 99.7% IACS Total Resistivity 1.738 micro-ohm cm Dimensional Specification Tooling is interchangeable between CABAC and Burndy. Conventional Connectors Catalogue No. C Conductor Range mm2 Run or Tap Dimensions (mm) Min Max A B C Crimp Die Crimp Die 5 Tonne 13 Tonne ‘C’ CACC25 16 25 21.4 13.0 17.0MC25-50 MC25-C CACC35 35 35 26.6 15.6 21.0MC35-50 MC35-C CACC70 50 70 34.0 21.028.0 MC70-C CACC95 70 95 41.0 26.029.0 MC95-C CACC120 110 125 45.0 28.030.0 MC185-C A A B B Conventional C-Connector CACC Wide Jaw C-Co C C Wide Jaw Connectors Catalogue No. CACD35 C Conductor Range mm2 Run or Tap Dimensions (mm) Min Max A B C 10 Crimp Die Crimp Die 5 Tonne 13 Tonne ‘C’ A A A 35 30.0 14.3 19.0 MC35-50HT130-CC A 39.0 19.019.0 CACD70 35 70 A A HT130-CO CACD120 95 120 52.0 24.022.0 HT130-C997 CACD240 150 240 74.0 34.428.0 HT130-C1011 B B Conventional C-ConnectorBCACC B Conventional C-Connector CACC B Wide Jaw C-Connector CACD Multifit C-Connector CACE C C Multifit Connectors Catalogue No. Wide Jaw C-Connector CACD Conductor Range mm2 Run TapDimensions (mm) Min Max Min Max A B C A CACE35/70 3570 1035 36.0 18.3 19.0 A Die Crimp 13 Tonne ‘C’ A HT130-CO CACE70/120 951201070 50.023.219.0 HT130-C997 CACE70/240150 2401070 62.030.922.0 HT130-C1011 CACE120/240 150 24095120 68.033.928.0 HT130-C1011 B Conventional C-Connector CACC B Wide Jaw C-Connector CACD B Multifit C-Connector CACE J35 Marker Tapes & Guards Warning Marker Tape Warning Marker Tape is laid in the ground close to the surface above the cable after partially back-filling the trench with soil or fill. It is a visual warning of the presence of Electrical cables buried below. • Warning marker tape is pulled up in digging action to alert people of the presence of the Electrical cables buried below. • Electric orange colour, marked every metre in black with the words “Caution Electrical Cable Below”. • Environmentally friendly - manufactured from recycled material. Catalogue. No. Width (mm) Length (m) Weight (kg) WMT150150 50 0.7 WMT150/360150 360 4.8 WMT150/500150 500 7.0 Technical Data Material: Polyethylene 100micron nominal thickness Operating Temperature: -20°C to 120°C Accepting Authorities: Energy Australia Integral Energy Electricity Services Victoria ERGON Tree Guard, Stay Guard and Possum Guard Tree Guard Tree Guard is designed to be retro fitted to existing conductors that have tree interference. It is primarily designed to act as an abrasion resistance on CATV and insulated conductors such as ABC. Tree guard is a UV stabilised plastic tube, with a longitudinal split to allow ease of installation. Tree guard split tube is designed to roll over itself so that it is range taking on the cable. Stay Guard Stay Guard is used on stay wires at ground level to provide abrasion protection from livestock, and to make stays visible to people. It is UV stabilised and available with or without a longitudinal split. Possum Guard A unique product developed by CABAC and now used by many authorities. It simply works by creating an unstable swivelling jacket around the overhead cable, and the possum falls off the cable if he walks along it. Simply attach a number of plastic swivels around the conductor, located in place with a cable tie, and your possum problems disappear. Catalogue No. Split / Un-split Colour Tree Guard VPTG25/3GSplit J36 Grey IDLength (mm) (m) 25 3 Technical Data Material: Polyetelene 14, low density Volume Resistivity: ASTM D 257>1016 Supplied: Stay Guard VPSG2.5SWSplit White 30 2.5 VPSG2.5UWUn-Split White 30 2.5 Possum Guard PPG Possum guard 38 100mm PPG2 70 100mm Possum guard In a pack of 8x 100mm lengths with a cable tie Cable Stockings (Grips) CABAC’s Cable Stockings are designed to pull cables through ducts and along trenches and act as permanent cable tensioners in industrial, mining and processing plant applications. All the grips work on the same principle, in that they “shrink” when fitted over the end of the cable, because of their peculiar helical design. When pulled via a hauling rope they grip, and the more they are pulled, the greater the grip. A properly selected and fitted cable grip, used under the correct operating procedure , should never slip. • Standard grips are constructed from two ply galvanised mild steel wire ropes. Stainless steel is available as a special. • Standard grips have an alloy ferrule. Copper and stainless steel ferrules are available as specials. • Standard grips have a soft eye. Galvanised or stainless steel thimbles are available as specials. • Nylon style grips are suitable for Aerial Bundled Conductors (ABC). The strengths shown in the tables are theoretical and are based on the metallic area and grade of wire. Since field conditions have so many variables, it is difficult to list a guaranteed strength. The main factors that will reduce the strength of Cable Stockings are uneven loading of the strands caused by irregularities in the cable end, and abrasion of the wires. Fitting of an incorrect size grip will lead to premature failure. Do’s and Don’ts • To increase life of grips, chamfer the end of the cable approximately 30° for a distance of approx half of the diameter. • Banding is required approximately 30mm from the mouth of the grip to guard against accidental release and ensure maximum reliability. It is also helpful to tape down securely the mouth end of the grip to reduce the incidence of fouling. • Ensure that the correct diameter grip is used. The size range is clearly stamped on the ferrule. • Store in a clean dry environment, and do not store nylon ABC style grips in sunlight. • Do not use a damaged grip, and inspect the grip after each pull. • Do not push the mouth of the grip against flat surfaces. • Avoid hauling over abrasive surfaces, however if this is not possible ensure regular inspections of the grip. J37 Cable Stockings (Grips) Tubular Single Eye CABAC’s “CG” range of stockings are the most common type of stockings, used for general cable hauling. They have a single eye and are integrally woven on a central axis. They are slipped over the end of the cable, and grip when pulled. They are made of two ply, galvanised steel wire strand with an alloy ferrule and soft eye. Variations such as galvanised thimbles, copper ferrules, stainless steel strand and stainless steel thimbles are also available. Please contact our sales. Catalogue To Grip Cable No. Diameter (mm) Grip Length Approx. (mm) Max Pull Approx. (kN) CG1010-14 350 CG1414-19 400 9 CG2019-28 500 15 CG3028-40 600 24 CG4540-55 800 35 CG6055-75 900 62 CG7575-95 1000 98 CG10595-120 133 1200 5 CG135120-150 1400 187 CG165150-190 1600 283 Ordering Variations StandardVariation (No Suffix) Suffix Grip Stainless Steel Rope SS Copper Ferrule Stainless Steel CF SF Galvanised Thimble Stainless Steel Thimble GT ST Gal. Wire Rope FerruleAlloy EyeSoft EG: Tubular single eye 60mm stocking in stainless steel with ferrule and eye CG60-SS-SF-ST. NB: If you wish to order a tubular single eye cable grip completely made of Stainless Steel for a 50mm dia cable you need to add suffixes to the catalogue number CG45 e.g. CG45 -SS-SF-ST. Please refer to the ordering variations table. Tubular Offset Eye CABAC’s Offset Eye Style cable stockings allow the cable to be passed through the grip to allow it to be secured at any point along the cable. It is mainly used for strain relief, with typical applications being permanent installations in process plants, mines etc. The standard offset eye style is manufactured from two ply galvanised strand with an alloy ferrule and soft eye. Variations such as galvanised thimbles, copper ferrules, stainless steel strand and stainless steel thimbles are also available. Please contact our sales. Catalogue To Grip Cable Grip Length Max Pull No. Diameter (mm) Approx. (mm) Approx. (kN) CG10OE10-14 350 5 CG14OE14-19 400 9 CG20OE19-28 500 15 CG30OE28-40 600 24 CG45OE40-55 800 35 CG60OE55-75 900 62 CG75OE75-95 1000 98 CG105OE95-120 1200 133 CG135OE120-150 1400 187 CG165OE150-190 1600 283 Ordering Variations StandardVariation (No Suffix) Suffix Grip Stainless Steel Rope SS Copper Ferrule Stainless Steel CF SF Galvanised Thimble Stainless Steel Thimble GT ST Gal. Wire Rope FerruleAlloy EyeSoft EG: Offset eye 20mm stocking in stainless with stainless ferrule and eye – CG20OE-SS-SF-ST J38 Cable Stockings (Grips) Tubular Double Eye CABAC’s double eye style allows the cable to pass through the grip. The extra eye allows the cable to be lifted into position with one eye, whilst the other eye is used to anchor the cable to a fixture. The standard double eye style is manufactured from two ply galvanised steel wire strand, with an alloy ferrule and soft eyes. Variations such as galvanised thimbles, copper ferrules, stainless steel strand and stainless steel thimbles are also available. Please contact our sales. Catalogue To Grip Cable No. Diameter (mm) Grip Length Approx. (mm) Max Pull Approx. (kN) CG10DE10-14 350 5 CG14DE14-19 400 9 CG20DE19-28 500 15 CG30DE28-40 600 24 CG45DE40-55 800 35 CG60DE55-75 900 62 CG75DE75-95 1000 98 CG105DE95-120 1200 133 CG135DE120-150 1400 187 CG165DE150-190 1600 283 Ordering Variations StandardVariation (No Suffix) Suffix Grip Stainless Steel Rope SS Copper Ferrule Stainless Steel CF SF Galvanised Thimble Stainless Steel Thimble GT ST Gal. Wire Rope FerruleAlloy EyeSoft EG: Tubular double eye 75mm stocking in stainless with stainless ferrule and eye - CG75DE-SS-SF-ST Lace Up Offset Eye CABAC’s lace up grips are made flat to allow the grip to be wrapped around the cable at any position, then secured by a lace. These grips are used where it is impractical to use a tubular grip, which has to be fitted and removed from the end of the cable. Lace up grips can be used in the central portion of a hauling job, to load share with a tubular grip. They are also ideal for retro fitting to cables in an industrial or mining application. The standard lace up style is manufactured from two ply galvanised steel wire strand, with an alloy ferrule and soft offset eye. Variations such as galvanised thimbles, copper ferrules, stainless steel strand, stainless steel thimbles and double eyes are also available. Please contact our sales. Catalogue To Grip Cable No. Diameter (mm) Grip Length Approx. (mm) Max Pull Approx. (kN) CG14LU14-19 500 9 CG20LU19-28 600 15 CG30LU28-40 800 24 CG45LU40-55 900 35 CG60LU55-75 1000 62 CG75LU75-95 1200 98 CG105LU95-120 1450 98 CG135LU120-150 1900 141 CG165LU150-190 2100 141 Ordering Variations StandardVariation (No Suffix) Suffix Grip Stainless Steel Rope SS Copper Ferrule Stainless Steel CF SF Galvanised Thimble Stainless Steel Thimble GT ST Gal. Wire Rope FerruleAlloy EyeSoft EG: Lace up offset eye 30mm stocking in stainless steel with stainless ferrule and eye - CG30LU-JJ-SF-ST. J39 Cable Stockings (Grips) & Heavy Duty Cable Stockings - Heavy Duty Advantages: •Maximum grip •Highest breaking strength •High tension rope and conductor hauling •To suit bare or insulated conductor •Copper shoulders provide protection from wear Standard Construction: •Multi Ply •Galvanised Strand •Alloy Ferrule •Soft Eye •Copper Shoulders Catalogue To Grip Cable No. Diameter (mm) Grip Length Approx. (mm) Max Pull Approx. (kN) CG10HD-CS10-15 750 37 CG15HD-CS*15-21 810 57 CG20HD-CS20-29 1040 73 CG30HD-CS27-35 1160 101 Ordering Variations StandardVariation (No Suffix) Suffix Grip Stainless Steel Rope SS Copper Ferrule Stainless Steel CF SF Galvanised Thimble Stainless Steel Thimble GT ST Gal. Wire Rope FerruleAlloy *Please note: CG15HD-CS is not stock item and ordered as required. EyeSoft EG: Heavy Duty stocking in stainless steel with stainless ferrule and stainless thimble CG30HD-CS-SS-SF-ST. ABC Cables - Nylon Insulated CABAC’s ABC style stockings are made from a non-conductive three ply nylon strand, specially for pulling bundles of Aerial Bundled Conductors. They are made non-conductive for safety reasons, to minimise the chance of flashovers and electrocution. They come standard as tubular, soft eye and alloy ferrule. They are also available in double eye and offset eye. Please contact our sales. Do not store these grips in direct sunlight. Catalogue To Suit Cable Colour No. (mm) Grip Length Approx. (mm) Max Pull Approx. (kN) White 600 15 CGLV450 4 x 50mm2 ABC bundle CGLV495 4 x 95mm ABC bundle Blue 800 25 CGLV4150 4 x 150mm2 ABC bundle Green 800 25 2 Cable Stocking Swivels - Clevis/Clevis Type CABAC’s swivels are used where there is a possibility of rotation or spinning passing from the pilot rope to the cable or vice-versa. This is often the case when an ordinary laid rope is used to haul with, instead of a braided rope. CABAC’s swivels are high quality ball bearing types manufactured from stainless steel, which have a lower friction than non-bearing swivels. The pins have a screwdriver slot for easy removal. Clevis/Eye types are also available. Please contact our sales. Catalogue No. Ultimate TensileDimensions (mm) Strength (Tonne) A B C D E F CGSSSW25CC 2.5T 87252512 8 9 CGSSSW19CC 1.4T 692219 9 6 11 A B D C E J40 F 2 Stage Jetline Blower 2 Stage Electric Draw Line Blower Kit This unit will effectively blow a lightweight jet line up to 1000m of unoccupied conduit. Each motor delivers approximately 3.5m³ of air per minute and is suited to long PVC duct runs with many bends. MSS-EBK2-1300K - Electric Jetline Blower Kit Contains: 1 x 240V electric blower unit 1 x 5m x 50mm diameter hose assembly with fittings 1 x Conduit sealer to suit 12mm-40mm conduit 1 x Conduit sealer to suit 50mm-100mm conduit 1 x Conduit sealer to suit 110mm-16vv0mm conduit MSS-EBK2-1300 - Electric Jetline Blower - no accessories NEW MSS-EBK2-1300K Draw Line Pressure Roping Gun And Seal Off Kit Used in conjunction with an air compressor this unit is suitable for conduits 50mm - 150mm and can accommodate rope 4mm-10mm. Kit Contains: 1 x Pressure roping gun 1 x 50mm Conduit seal off 1 x 80mm Conduit seal off 1 x 100mm Conduit seal off 1 x 125mm Conduit seal off 1 x 150mm Conduit seal off 4 x Grommets to suit 4mm, 6mm, 8mm and 10mm rope 1 x Carry case NEW MSS-DPL-500 J41 Hauling Swivels & Line Carriers Breakaway Swivels Our Break-away Swivels give you invaluable protection when pulling either fiber optic or coaxial cable. •These simple tools provide an inexpensive fracture point between the pulling line and cable avoiding costly cable damage if the cable’s rated pulling capacity is exceeded. •The swivels are available in two diameters; 7/8” (22 mm) made from high quality aluminium and 5/8” (16 mm) made from steel. Swivels sold with standard fuse: MSS-70188 16mm swivel with 2.2kn fuse MSS-53706 22mm swivel with 2.2kn fuse NEW 16mm Swivel Fuses Catalogue No. Break Point (kg) Colour Code MSS-26309 91 Orange/White MSS-26310 100 Red/White MSS-26305 134 Green/White MSS-30333 154 White MSS-26306 181 Blue/White Catalogue No. 154 White 22mm Swivel Fuses Break Point (kg) Colour Code MSS-26307 190 Yellow/White MSS-30332 MSS-26308 197 Violet/White MSS-34786 204 Orange MSS-25494 204 Orange MSS-34341 272 Yellow 364 Blue MSS-26325 226 Violet MSS-34342 MSS-25493 272 Yellow MSS-34343 454 Green MSS-26326 317 Brown MSS-34344 544 Red Stainless Steel Swivels These tough swivels are designed to handle higher thrust loads for extra cable safety and faster straight pulls. • Precision-machined body is made of high quality stainless steel with higher working load ratings than comparably sized swivels available on the market. • These heavy-duty swivels are built with a thrust bearing for tensile load and a radial bearing for bending load. Catalogue No. Diameter (mm) WLL Underground NEW WLL Aerial Length (mm) Eye Width (mm) MSS-70136 22 10.0kN 6.0kN 86 9.5 MSS-70137 32 22.2kN 13.3kN 105.6 13.5 MSS-70138 35 31.1kN 18.7kN 116.7 14.3 MSS-70139 41 44.5kN 26.7kN 138.1 17.5 MSS-70140 64 111.2kN 66.7kN 244.5 26 Balloon Line Carriers Shaped like a balloon with a rigid plastic mouth to ensure the balloon stays inflated. Available in the following sizes: J42 Catalogue No. Size (mm) MSS-DBL-050 50 MSS-DBL-080 80 MSS-DBL-100 100 MSS-DBL-125 125 MSS-DBL-150 150 MSS-DBL-190 190 MSS-DBL-225 225 NEW Hauling Rope Telstra Blue/Yellow Rope 6mm Polypropylene blue/yellow hauling rope - 400m coil. Catalogue No. Diameter (mm) Break Load (kg) 6 595 MSS-LPPFBY6 MSS-LPPFPY6-BULK Pallet of 45 coils NEW Polypropylene Rope Polypropylene hauling rope - 250m coil. Catalogue No. Diameter (mm) Break Load (kg) MSS-LPPHTA12 12 2700 MSS-LPPHTG16 16 4500 MSS-LPPHTA20 20 6900 NEW Double Braid Rope Double braid rope has been developed with a braided cover over a braided core to provide a single integrated rope with greater strength. Polyester double braid provides high strength with low elongation, good abrasion and UV resistance and remains easy to handle. Catalogue No. Diameter (mm) Break Load (kg) MSS-PPYBF10 10 2200 MSS-PPYBF12 12 3300 MSS-PPYBF14 14 4800 MSS-PPYBF18 18 6200 NEW Spectra Braid Rope Spectra Braid is constructed of a open weave Spectra fibre core and a tighter weave polyester cover. Spectra has a high resistance to chemicals, UV light and abrasion. Spectra braid is a high strength, low stretch and low creep rope. It is easily spliced. Catalogue No. Diameter (mm) Break Load (kg) MSS-PSYBS6 6 1450 MSS-PSYBS8 8 3300 MSS-PSYBS10 10 4500 MSS-PSYBS12 12 5800 MSS-PSYBS14 14 7600 NEW J43 Cable Blowers Tornado Cable Blower The Tornado cable blowing machine is capable of installing fibre optic cable (6-32mmO/D) at speeds up to 90m per minute into pre installed sub-duct (25-63mm). The system operates on the viscous drag principle employing compressed air to install the cable, controlled and assisted by a hydraulic belt drive system. An electronic monitoring system provides read out of speed and distance. The Tornado is equipped with an electronic pressure sensor which will shut down the hydraulic drive system in case an obstruction is found in the duct. NEW MSS-C-1250-0001-01 Note: Collets and seals are required for cables and sub-duct and depend on the size of the cable and duct being Installed. **Requires suitable air compressor. Hydraulic power pack The Cable “Over Blowing” Junction Box The cable “over blowing” junction box has been designed to install a new cable into an occupied sub-duct (subject to space). The junction box is comprised of a heavy duty aluminium base and lid that form a pressurized chamber into which one end of the occupied sub-duct can be attached. The existing cable can then exit the box from either side of the two branches to best suit the application. The vacant branch of the junction box is then connected to the tornado using a short length of sub-duct for the installation of the new cable. MSS-C-1254-001-01 Note: Collets and seals are required for cables and sub-duct and depend on the size of the cable and duct being installed. J44 NEW Winches Pull And Assist Capstan Winch NEW Skid mounted hydraulic pull and assist double capstan winch with capstan tilt function and rope take-up drum. The winch is powered by a 13HP petrol engine, driving triple mounted, fixed displacement pumps. One pump powers the double capstan via a hydraulic motor and epicyclical gearbox, another pump drives the rope take-up drum while the remaining pump powers the tilt function of the double capstan. Panel mounted controls are user friendly. The operation of the double capstan features two ‘dead man switch’ style, spring centred lever valves which control both direction and tilt function. The rope take-up drum function is operated via a simple ‘on-off’ style lever valve. Rope/cable tension can be controlled via a panel mounted, adjustable valve and a dial read out indicator showing tension in kg’s and pressure in PSI/BAR. The winch will stop pulling at the selected tension without stopping the engine, thereby protecting the cable. A ‘fixed’ valve can be used in lieu of the adjustable valve that sets the pressure of the hydraulic system to give a max tension of 2.2kN’s. The double capstan can be tilted through 90° from horizontal to vertical to suit the work being undertaken and the rope take-up drum can be used with the double capstan in any position. The rope take-up drum is removable and can be split to enable the easy removal of the rope. The base dimension of 1165mm x 1880mm makes it suitable for mounting on a trailer or ute tray. MSS-C1405-AU Specifications 500kg Small capstan pulling capacity: 1000kg Large/Small capstan diameters: 760mm/385mm Large capstan max pulling capacity: Rope speed: 50m/min Dimensions: L1880mm x W1165mm x H1100mm Weight: 580kg J45 Winches Powerful Petrol Powered Portable Capstan The RW300 winch is a powerful petrol powered portable capstan winch developed with the electrical and telecommunications industry in mind. Powered by a 4Hp Honda petrol motor it is capable of pulling loads up to 3kN. It is fitted to a sturdy galvanized steel frame with a tow ball attachment that will fit on any standard 50mm tow ball. MSS-RW300-4HP Specifications • • • • • 4hp Honda OHV 4 stroke petrol motor. Transtechno 25:1 Helical gear box. Emergency stop button with 2m lead. 90mm dia Capstan with rope diverter. Mounted on a plated frame with shaft protection Guard and tow ball attachment. • 1.5kN Continuous line pull. 3.0kN Maximum. • Weight - 36kg. NEW Rugged Electric Portable Capstan The 300AB winch is a rugged electric portable capstan winch suitable for overhead line crews and underground cable installers. Capable of hoisting weights up to 725kg double line lift. MSS-300AB-FS-771130 Specifications • • • • • • • 360kg single line or 725kg double line lift. 230V 1.25hp reversible braked motor. Speed 9 MPM at 500kg load lift. Worm gear reduction for positive load holding. Low voltage pendant hand or foot control. Capstan rope drum. Fitted to a heavy duty angle steel base with mounting points. NEW J46 Cleaners & Mandrels Rubber Conduit Cleaner Suitable for clearing the conduit of sand, mud and other debris. Catalogue No. Size (mm) MSS-CRC-050 50 MSS-CRC-080 80 MSS-CRC-100 100 MSS-CRC-125 125 MSS-CRC-150 150 NEW Rubber Slug Suitable for clearing the conduit of sand, mud and other debris and spreading lubricant especially on tight radius corners. Catalogue No. MSS-RS-050 Size (mm) 50 MSS-RS-080 80 MSS-RS-100 100 MSS-RS-125 125 MSS-RS-150 150 NEW Conduit Proving Mandrels Used for testing conduit integrity before hauling in cable. Available for testing electrical and communications conduits in the following sizes. Catalogue No. Conduit Size MSS-DPM-050 50mm MSS-DPM-100 100mm MSS-DPM-125 125mm MSS-DPM-150 150mm NEW J47 Drum Stands Drum Cradle Drum cradle suitable for lifting, supporting and lowering cable drums for cable installation. Supplied with a 1250mm x 48.3mm spindle bar with collets to keep the drum centered on the spindle. This unit has been tested by an independent test facility with a 7.9:1 ratio of the Safe Working Load. MSS-DL-150 Max Drum Diameter 1500mm Max Drum Width 1000mm Height 770mm Width 1250mm Length 1780mm Weight 25Kg Recommended working load limit 150Kg WWL (Tested) 1200kg NEW WARNING: For the safety of the operators, CABAC recommends that this unit is to be operated by two persons!! Drum Ramp Rollers For use with drum diameters up to 1.5m with a safe work load of 1.5 tonne (per set). Fold away for easy storage. MSS-DRR-1000 NEW Cable Reel Dispenser Stand To suit 2 to 3 reels of electrical cable. MSS-CRS350 NEW Cable Drum Trolley To suit 90cm wide x 1mtr diameter drum up to 500kg MSS-CDT-500 NEW J48 Drum Stands Scissor Type Cable Drum Jacks NEW Suitable for lifting cable drums up to 4 ton. Fully collapsible for easy transportation. Set up in minutes. Catalogue No Jack Size (tonne) Drum Radius (mm) Drum Diameter (mm) Drum Width (mm) Drum Weight (tonne) Drum Shaft (mm) Jack Width (mm) Jack Length (mm) Folded Height (mm) Weight Per Set (kg) MSS-SLS1-2T MSS-SLS3-4T 1-2 900 1800 1800 1-2 63 460 1350 250 100 3-4 1200 2400 2000 3-4 90 460 1700 250 160 Hydraulic Cable Drum Jacks NEW Suitable for cable drums up to 8 ton. Works with the use of bottle jacks fitted to the base to lift the drum off the ground. image shows optional Disc brake feature. MSS-DJS-58T Available Accessories: MSS-DB-400 - Disc brake and fixing arm set to suit 40mm dia axle MSS-DB-630 - Disc brake and fixing arm set to suit 63mm dia axle MSS-DB-900 - Disc brake and fixing arm set to suit 90mm dia axle Jack Size (tonne) Drum Radius (mm) Drum Diameter (mm) Drum Width (mm) Drum Weight (tonne) Drum Shaft (mm) Jack Width (mm) Jack Length (mm) Jack Height (mm) Weight Per Set (kg) 5-8 1650 3300 2000 5-8 90 460 1350 250 156 J49 Cable Lubricant Powergel Water Based Lubricant POWERGEL is a water based cable hauling Lubricant, which provides excellent friction reduction, for hauling heavy power, telecommunication and fibre optic cable. Compatible with all forms of cable jacket and does not stress crack polyethylene plastics. Non-toxic and Non-Flammable. MSS-LN1477-4 - 4 Litre MSS-LN1477 - 20 Litre NEW Ductglide Water Based Lubricant DUCTGLIDE water based cable blowing lubricant specifically designed for lubricating sub-duct prior to high speed fibre optic cable blowing. Compatible with all forms of cable jacket and does not stress crack polyethylene plastics. Non-toxic and Non-Flammable. Available in 20 litre drums. MSS-LN1478 J50 NEW Manhole Cable Guides Single Manhole Roller Guide 120mm wide aluminium roller. MSS-TRGM-100 NEW Twin Manhole Roller Guide 2 x 120mm wide aluminium rollers. MSS-TRGM-100-2 NEW Triple Manhole Roller Guide 3 x 120mm wide aluminium rollers. MSS-TRGM-100-3 NEW Pivoting Manhole Slipper Guide 100mm cable slipper. MSS-PMCG-100 NEW Pivoting Manhole Cable Guide 3 x 140mm aluminium rollers. MSS-PMRG-140 NEW J51 Conduit Cable Guides Conduit Slipper Guide Suitable for use in conduit up to 150mm to provide a smooth surface for the cable to glide easily against. Catalogue No. Conduit Size MSS-CCG-028 28mm MSS-CCG-035 35mm MSS-CCG-050 50mm MSS-CCG-080 80mm MSS-CCG-100 100mm MSS-CCG-125 125mm MSS-CCG-150 150mm NEW Lockable Conduit Slipper Guide Suitable for use in conduit up to 150mm locking to the inside of the conduit to provide a smooth, stable surface for the cable to glide easily. Catalogue No. Conduit Size MSS-CLS-050 50mm MSS-CLS-080 80mm MSS-CLS-100 100mm MSS-CLS-125 125mm MSS-CLS-150 150mm NEW Lockable Conduit Roller Guide Suitable for use in conduit up to 150mm locking to the inside of the conduit to provide a free running aluminium roller for the cable to glide easily. Catalogue No. Conduit Size MSS-FS-050 50mm MSS-FS-063 63mm Elec conduit MSS-FS-080 80mm MSS-FS-100 100mm MSS-FS-125 125mm MSS-FS-150 150mm NEW Bellmouth Conduit Guide Suitable for use in Electrical and Telecommunication Conduit – sizes available – 100mm , 125mm & 150mm. Cast Aluminium Bell Mouth Guides assist in Protecting Cable upon entry during cable Hauling process. Catalogue No. Conduit Size J52 MSS-BM100 100mm MSS-BM125 125mm MSS-BM150 150mm NEW Cable Rollers Trench Corner Roller Used to create a 90° bend. Star pickets sold separately. MSS-TCR-200 NEW Raised Trench Roller - Aluminium 140mm wide aluminium roller. MSS-RTRA-140 NEW Flat Trench Roller - Aluminium 120mm wide aluminium roller. MSS-NTRA-120 NEW Raised Trench Roller - Plastic 140mm wide plastic roller. MSS-RTR-140 NEW Flat Trench Roller - Plastic 120mm wide plastic roller. MSS-NTR-120 NEW J53 Manhole Guards Supervisor Aluminium Foldaway Manhole Guards Suitable for storage in station wagon or sedan. Approved for Telstra use. NEW MSS-MGA-070 Weight 12.8kg Height 930mm Length 1430mm Width 1400mm Aluminium Foldaway Manhole Guards NEW Approved for Telstra use. MSS-MGA-140Y Weight 10.6kg Height 930mm Length 1430mm Width 1400mm Aluminium Folding Manhole Guards With Roof Frame To suit tent. Approved for Telstra use. MSS-MGA-140RY Weight 12.8kg Height 930mm Length 1430mm Width 1400mm NEW Waterproof Canvas Tent With Window And Door Flap For use with manhole frames with roof frame. MSS-TENT-01 NEW Aluminium Foldaway Manhole Guards Not approved for Telstra use. NEW MSS-SMTF38 J54 Weight 7.2kg Height 930mm Length 1430mm Width 1400mm Fibre Splicing Tent Designed to protect workers from the elements, these brightly coloured tents are easily seen by oncoming traffic. Utilising a unique new hub design, the tent pops up or down in a matter of seconds and requires no assembly. The white and bright yellow fabric is a durable water repellent, 200 denier nylon/polyester. The Utili tent features adjustable rod ends for side wall tension, a zipped door, vent windows on each side and tie down loops on all corners for additional ground anchoring. Material • • • • • • • • • • 250 denier Polyester. Fabric Weight – Minimum: 4.55 oz./yd. Maximum: 5.20 oz./yd. Urethane coating. Spray rating per ATCC #22. Coated weight of fabric per ASTM D3776-96. Fire retardancy per CPAI-84 & NFPA 701. Fabric count per ASTM D3775-96. Water repellence test per AATCC 127 – 1986. Tensile Strength of fabric per ASTM D5034-95. Elongation of fabric per ASTM D5034-95. NEW Frame • Solid white protruded fibreglass rods. • Mechanical properties per: ASTM D3916/D63B, D4476/790, D695, D2583, D256, D149, D150, D495, D792, D2584, D570 & D696. Hubs All hubs are made from one of three materials: Cast Zinc #3 per SAE 903, ASTM AG40A Type 380 Aluminium Cast Zinc #5 per SAE 925, ASTM AC41A Tie down loops on all corners for additional ground anchoring Construction • • • • • • All edges and seams are finished. 18 oz. Reinforcing material in corner rod pockets. Black, UV resistant cable ties. Windows have Velcro or snap in place closures for foul weather. Heavy duty non-metallic zippers for door closures. Set-up instructions are sewn onto storage bag. MSS-TEL83-41 Vent Window Hole for an air blower J55 Section J.a Lighting Photo Sensing Switch & Cable Clamp Set J56 J.a57 - J.a58 Street Light Insulated Terminal Block, Street Light J.a59 Mining/Confined Space J.a60 Photo Sensing Switch CABAC IS THE EXCLUSIVE DISTRIBUTOR OF D2 Photo Sensing Switch The HSC-PE2 is a light sensing switch for controlling mains powered street lighting, designed to switch ON at low light levels and OFF at high light levels. The controller is provided in industry standard D2 format. The controller uses an electronic sensor circuit, providing higher reliability and superior temperature stability of light level switching thresholds. •Silicon Light Sensor – Non Containing •Hybrid technology - more reliable reduces drift •Approved by all major power authorities •Electronic light sensor circuit for accurate light level operation •Mechanical contacts for proven reliability •Industry standard D2 format •Conforms to AS 1158-6 •175 Joule MOV •High Impact acrylic case •Solid brass contacts •Wide operating voltage range (185 Vac to 305 Vac) •Switches ON in the case of failure of the light sensing element HYBRID TECHNOLOGY MORE RELIABLE REDUCES DRIFT HSC-PE2- Photo Sensing Switch Applications - Suitable For: •Category P1 to P5 - Minor Road Lighting - collector/distributor roads, local roads, cycle paths, etc. •Category P6 to P12 - Public Area Lighting - town centres, town squares, pedestrian malls, footpaths in parks, carparks etc. All specifications apply at a Tamb of +25°C unless otherwise specified. Parameter Value Nominal supply voltage 50 /60 Hz 240 Vac Supply voltage range 185 - 305 Vac Max. Load Rating 700W (3A @ 230 Vac) Failure Mode ON Operating Temperature range - 40ºC to + 65ºC Surge protection 175 Joule MOV Power consumption Average <2W Operating light levels Turn ON: 10 lux ± 5 lux Turn OFF: 40 lux ± 12 lux (OFF:ON Ratio = 4:1) Time Delay (at 230 Vac supply) Turn ON: 30 secs (typ.) Turn OFF: 25 secs (typ.) Photo-cell Si sensor Suitable D-2 mounting base Z60160 (Sylvania) HSC-PE2 Mechanical Information 52 max 12 1 26 2 3 HSC-PE2 Application Circuit Active 1 HSC-PE2 2 230Vac Mains 3 Lamp Ballast metal halide lamp Neutral HSC-PE2 - application circuit J.a57 Photo Sensing Switch CABAC IS THE EXCLUSIVE DISTRIBUTOR OF Twist-Lock Electronic Photocontrol The HS6390B and HS6390B-C are light sensing switches for controlling mains powered street lighting, designed to switch ON at low light levels and OFF at high light levels. The difference between the HS6390B and the HS6390B-C is the B- C version uses Cadmiun Sulfide Photocell and the B version uses Encapsulated Silicon Phototransistor. These twist-lock electronic photocontrol features rugged design and are available in two standard models of sensing technology, with options to satisfy a wide variety of applications. •Double-sided plated through control board making it rugged, of a superior quality & reliable •Quad Gate technology - constant switching levels over a wide range of voltages & temperatures •Unique twist grip design - tough, tighter switching levels •Reduces power usage •320joule MOV •High impact thermoplastic base BEST •Solid brass contact blades CONSTRUCTED •UV stabilised permanent colour NEMA IN THE MARKET •High impact resistant polyproylene cover AS 1158-6 HS6390B HS6390B-C HSC-5927-AUS - Bracket Applications - Suitable For: •Category V1 to V5 - Major Road Lighting - freeways, arterial road, sub-arterial roads, collector roads etc. •Category P1 to P5 - Minor Road Lighting - collector/distributor roads, local roads, cycle paths etc. •Category P6 to P12 - Public Area Lighting - town centres, town squares, pedestrian malls, footpaths in parks, carparks etc. Parameter Nominal supply voltage 50 /60 Hz Supply voltage range Failure Mode Load Rating Operating Temperature Photocell Dielectric Strength Surge Protection Power consumption Time Delay Off (Instant ON) Operating Light Levels (Standard Settings) ANSI Color Coded Cover HS6390B HS6390B-C 240 Vac 105 - 305 Vac ON 1000 Watt Tungsten/ 1800 VA Ballast -400C to +700C Encapsulated Silicon Phototransistor 5000 Volts between current carrying parts and metal surfaces 320 Joule MOV/ 10,000 amp surge current 0.5 Watts @ 120 V 3 to 5 seconds Turn on 15 Lux ±15% Turn off by 22.5 Lux (Off: On ratio = 1.5:1) Blue (Standard) 240 Vac 105 - 305 Vac ON 1000 Watt Tungsten/ 1800 VA Ballast -400C to +700C Cadmium Sulfide 5000 Volts between current carrying parts and metal surfaces 320 Joule MOV/ 10,000 amp surge current 0.5 Watts @ 120 V 3 to 5 seconds Turn on 15 Lux ±15% Turn off by 22.5 Lux (Off: On ratio = 1.5:1) Blue (Standard) Street Light Poles Cable Clamp Set The SBK kits are safety items for street light poles. These kits are placed near the ground and connected to the mains supply feeding a street light. The purpose is to disconnect the mains power if the pole is pushed over due to a motor vehicle accident or enviromental condition e.g. cyclone. Assembly of SBK02 in a street light pole. SBK01 (grey brackets) Slipbase kit - 01: Contains CCB-1 & CCB-2 (grey bracket x 2) x XP5442PKIT (heatshrink) SBK-01 Slipbase kit - 02: Contains CCB-PP-SY-ASK (yellow bracket x 2) & XP5442PKIT (heatshrink) SBK-02 Special assemblies for street lighting. Custom assemblies available on request. J.a58 Shear Plain SBK02 (yellow bracket) Street Light Insulated Terminal Block Street Light Power Block The TB503B has been designed to replace the existing switchboard that supplies the power to the street light fitting. An Australian electrical supply company approached CABAC to modify the existing setup to make the switchboard user friendly and provide over finger protection. The new block offers the following features: • Finger protection was achieved by shrouding on the wiring end of the terminal • The loop in and loop out cables could be up to 50mm2, carry 200Amps. • Compact design • Blanks attached on blocks that do not need loops. The block caters for main 6mm2 (power to the light fitting) cables, all been able to be terminated with a suitable Allen key. TB503B 3 Way Terminal Block 16mm2+2 front 6mm2 TB503A 3 Way (2-6mm Cable Tunnels For Lighting Conductors) Technical Data Conductive Material Brass alloy tinned Set Screw Material Brass alloy tinned Cover MaterialPolycarbonate Typical installation using TB503A. Accepting Authorities Approved by Energy Australia TB503A Top View TB503A Rear View TB503B Top View TB503B Rear View Street Light Controllers Three pole version as shown. Other variations available on request. SL-CU-3P-16-OP Street Light Controller (Pressed Aluminium Enclosure) SL-CU-3P-16-SQ Street Light Controller (Cast Aluminium Enclosure) Custom assembled controllers available on request. Contact our sales team for details. SL-CU-3P-16-SQ Street Light Protection SL-CBR-1-AS Street Lights Protector (Greased Terminals) SL-CBR-2-AS Street Lights Protector (Non Greased Terminals) CBR-BRACKET Mounting Bracket Custom assembled controllers available on request. Contact our sales team for details. CBR-BRACKET SL-CBR-1-AS J.a59 Mining / Confined Space SmithLight - Heavy Duty Portable LED Light The SmithLight has two different height settings, and a multitude of angle settings for the light head itself. The light head is fitted with over 250 LED’s and can be used in a variety of settings – side A only, side B only, or both sides to emit light in all directions. Weighs only 7.7kg (including accessories, battery and components). The battery can power the light for 10-12hrs, and is easily rechargeable from any 240V GPO, or from a vehicles 12V cigarette lighter. SMIN120L NEW SmithLight Ex - Instrinsically Safe Portable LED Light This SmithLight has all of the same features and functions at the standard SmithLight (above) with the extra benefit of being EX rated for use in hazardous areas. The SmithLight is available with various attachment clamps to use in various situations. Mounting options available include a tripod, as well as stabilising brackets and Pole-mounts. The SmithLight of course also be used stand alone for ground level or trench and pit work. SMEX90L NEW J.a60 Section J.b Rail and Locomotive DC/DC Supplies and Battery Chargers IntroductionJ.b62 Regulated DC/DC Converter J.b63 High Power DC/DC Converter J.b64 Rail Battery Chargers J.b65 - J.b66 Introducing CABAC/CCI Rail Products The Cabac CCI Rail power supplies provide DC power solution for a wide range of application within the cabins of diesel locomotives and in the safety critical application of level crossing battery charges. The DC/DC power supply use an advanced design creating a power supply efficiency that exceeds 90%. The class leading efficiency of the design results in a power supply that needs no fans or external cooling fins. The supply is completely encased effectively blocking out diesel particulate,which can build up on electronic and cause failures. As a result the Cabac/CCI DC/DC Power Supplies have an unrivalled reputation for rugged reliability in often hot and dirty environments. The Cabac/CCI range of DC/DC supplies are regulated, come in 13.8VDC and 24VDC and can be used to supply essential communication and safety equipment like radio, GPS, satellite tracking and Telemetarey Communications, can drive windscreen wipers and headlights and also driver comfort devices like refrigerators and fans. If you cannot find a model to suit your needs in the following range - we design & manufacture locally - please contact us with your requirements. Wide Range DC/DC Power Supply Application DC/DC Power Supply used in Locomotive applications. The WR series power supply operates with a wide range of input voltages. Typically either 72V DC or 110V DC are source voltages used in locomotive applications. The WR series wide range allows the power supply to be used in either voltage application seamlessly, allowing for maximum flexibility in stocking and change out regimes. Output used for 12VDC applications Features Benefits Advantage No External Fins Operates in position with restricted airflows No special ventilation required, install it anywhere Fan-less Design High Reliability Fans are susceptible to failure – the lack of a fan increases reliability 90% Efficiency No Ventilation Ports Required Reduces dust ingress which increases reliability. Wide Range Operational in 72VDC or 110VDC Applications Flexibility in change out and stocking regimes Specifications WR150E-13V8-10A Wide Range Input Output Voltage Regulation (Vin = 55 – 137V, Iout = 10A) Regulation (Vin = 48 – 55V, Iout = 10A) Input Fuse Output Fuse Input LEDs are ON if I/P is Output LEDs are ON if O/P is Efficiency Vout = 11.5VDC – 13.8VDC 10A > 12VDC Vout = 20.6V – 24.1V Isolation I/P to GND 1kV Minimum Isolation O/P to GND 500V Minimum < 50mV (Typically <= 25mV @ 10A & Vin=55 – 137V ) Vout = 11.5V – 13.8V 4A 6.3A 10A within range 55 – 137VDC > 22VDC > 12Vdc 88 – 92% Depending on Load Conditions I/P to O/P 1kV Minimum Operating Temperature Size WR200E-13V8-15A 13.8Vdc ( +/- 50mV) < 1% Isolation Ripple & Noise J62 13.8VDC ( +/-50 mV ) WR150E-24-6A WR150EQ-13V8-10A 55 – 137VDC (For output regulation < 1% ) 24.1Vdc ( +/-100mV) 13.8Vdc ( +/-50 mV ) < 100mV < 50mV (Typically <= 50mV @ (Typically <= 25mV 6A3 & Vin=55–137V ) @ 10A & Vin=55 – 137V ) 0 – 60ºC L184mm x W110mm x H62mm Vout = 11.5V – 13.8 V 15A > 12Vdc I/P to O/P 1kV Minimum (Tested) I/P to GND 1kV Minimum (Tested) O/P to GND 500V Minimum (Tested) < 50mV (Typically <= 25mV @ 15A & Vin = 55 – 137V ) Regulated DC/DC Converter Regulated DC/DC Power Supply Application DC/DC Power Supply for Locomotive applications. The MR series DC/DC converters typically operate above 95% efficiency at full load over the specified input range. The MR converters have been designed to operate with the 72VDC supply voltage commonly found in most locomotives. The MR series uses electronic current sensing instead of a fuse for increased efficiency and reliability. If the supply becomes overloaded it will cycle the output on and off whilst the problem persists and afterwards resume normal operation. The supply is able to handle loads requiring a high surge current to operate such as lamps and motors. MR200E-13V6-15A MR400E-24V-16A Features Benefits Advantage No External Fins Operates in position with restricted airflows No special ventilation required, install it anywhere Fan-less & Fuse-less Design High Reliability Fans & Fuses are susceptible to failure – eliminating them increases reliability 90+% Efficiency No Ventilation Ports Required Reduces dust ingress which increases reliability Compact Size for rated power Ease of mounting position Small size allows for mounting unit right where you need it Specifications MR150E-13V6-10A MR150E-24V-6A 13.6Vdc ( +/- 50mV) 24.1Vdc ( +/- 100mV) Input Voltage Output Voltage MR200E-13V6-15A 13.6Vdc ( +/- 50mV) 13.6Vdc ( +/- 50mV) 24.1Vdc ( +/- 100mV) Vout = 11.5V – 13.6 V Vout = 22V – 24.1 V < 1% Regulation ( Vin = 55 – 60V, Vout = 11.5V – 13.6 V Iout = 16A ) Input Fuse Vout = 22V – 24.1 V Vout = 11.5V – 13.6 V 8A 4A Output Fuse No Fuse – internal Protection Input LEDs are ON if I/P is within range 60 – 78Vdc > 12Vdc > 20Vdc > 12Vdc > 12Vdc > 20Vdc < 50mV (Typically <= 25mV @ 30A & Vin = 60 – 80V ) < 100mV (Typically <= 50mV @ 16A & Vin = 60 – 80V ) Efficiency Typically 95% at full load Isolation I/P to O/P 1kV Minimum (Tested) Isolation I/P to GND 1kV Minimum (Tested) Isolation Ripple & Noise Operating Temperature Size MR400E-24V-16A 65 – 80Vdc ( For output regulation < 1% ) Regulation ( Vin = 60 – 80V, Iout = 16A ) Output LEDs are ON if O/P is MR400E-13V6-30A O/P to GND 500V Minimum (Tested) < 50mV (Typically <= 25mV @ 10A & Vin = 60 – 80V ) < 100mV (Typically <= 50mV @ 6A & Vin = 60 – 80V ) < 50mV (Typically <= 25mV @ 15A & Vin = 60 – 80V ) 0 – 60ºC L184mm x W110mm x H62mm J63 High Power DC/DC Converter High Power DC/DC Power Supply Application DC/DC Power Supply used in Locomotive applications. The MR series power supply operates at 72VDC, commonly available in locomotive applications. The MR has a tightly regulated out specifically designed to operate safety and mission critical devices in the driver cabin typically radios and communications units, computers, system controls, PLCs and other electrical device. 24WR500E-13V8-30A MR850E-13V6-60A Features Benefits Advantage Highly Regulated – low noise design Eliminates electromagnetic inference. No External Fins Fan-less Design 90% Efficiency Operates in position with restricted airflows High Reliability No Ventilation Ports Required Provides a stable supply for critical components like communication devices, PLC and other critical devices No special ventilation required, install it anywhere Fans are susceptible to failure – the lack of a fan increases reliability Reduces dust ingress which increases reliability Specifications Input Voltage Output Voltage Regulation Minimum load Input Fuse Output Fuse Input LEDs is ON if Input is Output LED is ON if O/P is MR850E-13V6-60A MR850E-24V-35A 24WR500E-13V8-30A 60 – 78 Vdc 13.6Vdc ( +/-200 mV @ 72V In 60A load) Below 1% for min to max Load & Supply 60 – 78 Vdc 24.1Vdc ( +/-200 mV @ 72V In 35A load) Below 1% for min to max Load & Supply 18 - 35 VDC – – 15A x 2 (separate fuses for the 72V + & - inputs) 4 x Separate auxiliary Fused outputs 15A x 2 (separate fuses for the 72V + & - inputs) 4 x Separate auxiliary Fused outputs 2x15A 1x10A 1x5A 1xSpare Within range 60-78V DC Within range 60-78V DC Within range 18 – 35VDC < 2% From no load to max load current. No Minimum load necessary to meet above spec. 10A > 11.5V DC > 22V DC > 12VDC Efficiency ~ 95 % Depending on Load ~ 95 % Depending on Load ~90% Depending on Load Conditions Isolation I/P to O/P 500V Minimum (Tested) I/P to O/P 500V Minimum (Tested) I/P to O/P 500V Minimum Isolation Isolation Ripple & Noise I/P to GND 500V Minimum (Tested) I/P to GND 500V Minimum (Tested) I/P to GND 500V Minimum O/P to GND 10Mohm Minimum O/P to GND 10Mohm Minimum O/P to GND 500V Minimum (Tested) (Tested) < 250mV (Typically < 150mV @ 60A) < 350mV (Typically < 200mV @ 30A) < 100mV (Typically <= 100mV @ 40A) Operating Temperature 0-60°C Inrush Current – – 100A for 1 ms, Falls to Max<30A within 5 ms. Input Over-Voltage Protection – – Transorb 3.0 kW Peak Power @ 45V Input/Output Connector – – Faston Spade (Automotive style) 6.3mm. 2.3kg 2.3kg As supplied in Carton: 2.01 kg 280mm x 165mm x 65mm 280mm x 165mm x 65mm 280mm x 165mm x 65mm Weight Size J64 13.8VDC (-0 / +100 mV) Rail Battery Chargers Single Cell 4A Battery Charger 80Vac-270Vac Input 2.3VDC Output Application The SC4A single cell charger has been designed to maintain Cyclon and similar single cells at their optimum state of charge over a wide range of ambient temperature. This will help maximise their useable life span before failure or replacement becomes necessary. Features Benefits Advantage Short circuit protection When output is short circuited charger goes into low current mode Temperature compensated charging Ensures Battery Life is Maximised Protect charger from damage in the event that the outputs are shorted Reduces Battery Replacement cycle – lowers cost of operation Current limited boost charge Cannot overload charger circuit – if the battery is extremely discharged Operation from 70 – 270VAC Widest available input Voltage Range Isolated output (+ or –) Output can be grounded Small size Mounting Anywhere Industry Standard Clips onto DIN rail no screws required Din rail mounting Indicators for power on, open circuit, short circuit, low battery voltage, boost and float modes Very low back-flow current from battery during power failure Protects charger from damage Reliable charging even in remote locations with poor supply Works with positive, negative or floating grounding system Light Weight, easy shipping and storage Simple to install Comprehensive Real-time monitoring and indication Simple fault analysis and rectification. If there is a power failure the battery does not discharge through the unit Maximum operating time and reliability for critical applications Specifications SC4A Input Voltage 80 - 265VAC Input Current ~250mA @ 110VAC Output Voltage Output Voltage compensation Output Current Operating Temperature Efficiency 2.25V –2.35V @ 25Deg C ( adjustable, factory set to 2.30V ). 2.55V@ -10DegC, 2.20 V@50Deg C ( Slope of ~ -3mv/Deg C ) 4.0A (maximum) Current limited 60 Deg C No derating required ~ 72% Size / Weight ~ 110mm x 70mm x 70mm, ~ 300grams Connections Input AC Screw Terminals, Output DC Pluggable terminal block Mounting 35mm Din-Rail Warranty 3 Years from date of purchase. MTBF > 200,000 hours estimated J65 Rail Battery Chargers Sealed Lead Acid 6,7 & 8 Cell Battery Chargers 110Vac-240Vac Input Application The SLX678 series chargers are designed to maintain Sealed Lead Acid and similar batteries at their optimum state of charge over a wide range of ambient temperature. This will help maximise their useable life span before failure or replacement becomes necessary. SLX678-10 10A Battery Charger SLX678-15 15A Battery Charger SLX678-15 Features Operation from 110 & 240VAC. Isolated output (+ or –) Inbuilt continuous Battery circuit Detection & validation Front Panel LCD Display. Temperature compensated charging. Inbuilt Auxiliary 5A Charger 6,7 & 8 Multiple Cell Selection Float-Voltage Adjustment LED Indicators for Charger OK, Battery low, Float and Boost modes. Very low back-flow current from battery during power failure. “Pluggable” connectors Benefits Advantage Suits Rail 110V applications and can also utilise 240V when available Works with positive, negative or floating grounding Suits floating or grounded use. system. Early notification of impending issue rather than Alarms within minutes of a battery circuit fault finding out when the power goes off Multi-function displays for status & setup & other Instant view of charge voltage and current diagnostics Reduces Battery Replacement cycle – lowers Ensures Battery Life is Maximised cost of operation Extends operational time In the event of a main Maximises operational time until field service charger fault. tech arrives Only one charger to stock One charger suits most sites Float charger can be altered to suit a specific Works with all popular Cell types requirement or Cell type Suits 110V & 240V sites Simplifies diagnosis Speedy fault analysis and rectification. Battery does not discharge back into the unit during a power failure No exposed wires Maximum operating time and reliability for critical applications Fast and safe changeover Specifications SLX678-10 Input Voltage 110V - 240VAC Input Power (No Load) Below 30 Watts Output Voltage 6, 7 & 8 Cell Output Voltage compensation Output Current 2.25 – 2.3V per cell adjustable, factory set to 2.27V Slope of ~ -3mv/Deg C 10.0A maximum - Current limited Operating Temperature 50ºC No derating required Size (H x W x D includes mounting flanges) 240mm x 326mm x 210mm Weight Connections Warranty J66 SLX678-15 13kg AC In, Battery Out, Charger OK Led, External Alarm 2 Years from date of purchase