Three-phase asynchronous motors with squirrel

Transcription

Three-phase asynchronous motors with squirrel
Three-phase
asynchronous motors
with squirrel-cage rotor
for potentially
explosive atmospheres
VEM motors GmbH
Table of contents
Technical explications
Motors in the increased safety type of protection EEx e
Motors in the flame-proof enclosure type of protection EEx d
Motors in the non-sparking type of protection Ex nA
Motors for being used in case of potentially inflammable dusts (zone 21, 22)
EC certificates of conformity and EC certificates of sample test
Standards and specifications
Tolerances
Tolerances of the design values
Tolerances of the fixing dimensions
Mechanical design
Types of construction
Shaft ends
Degrees of protection
Sense of rotation
Bearing arrangement / bearing lubrication
Application of cylinder roller bearings
Transport locking
Vibration behaviour
Noise characteristics
Cooling and ventilation
Paint coat
Page
1
1
1
2
2-4
5
6
6
6
7
8
8
8
8
8
8
8
9
9
9
Electrical design
Design voltage and frequency
Design torque
Design output
Additional thermal winding protection
Overload capacity
Design efficiency and power factor
Restarting in case of residual field and phase opposition
9
9
10
10
10
10
10
Project planning and user instructions
Hazardous areas
Installation and electric connection
Protective measures against inadmissible temperature rise
Maintenance and repair
Spare parts
10
11
11
11
11
Selection data
Increased safety type of protection EEx e II
Electrical selection data
Dimensions
Bearing
Terminal boxes
Flameproof enclosure type of protection EEx d II / EEx de II
Electrical selection data
Dimensions
Bearing
Terminal boxes
Non-sparking type of protection Ex nA II
Electrical selection data
Dimensions, see data for zone 21 Ex II 2D
Bearing, see data for zone 21 Ex II 2D
Terminal boxes, see data for zone 21 Ex II 2D
Motors for being used in case of potentially inflammable dusts, zone 21; Ex II 2D
Electrical selection data
Dimensions
Bearing arrangement
Terminal boxes
Motors for being used in case of potentially inflammable dusts, zone 22; Ex II 3D
Electrical selection data
Dimensions
Bearing
Terminal boxes
Marketing / Delivery program
Reservation of modifications: Subject to modifications of output, technical data, dimensions and weights specified in the list.
The illustrations are not binding.
12 - 23
24 - 25
26
27
28 - 31
32 - 33
34
35
36 - 39
40 - 43
44 - 45
46
47
48 - 51
52 - 53
54
55
56
Technical explications
Squirrel-cage motors, increased safety type of protection „e“
Constructive version
Series
Sizes
Degrees of protection
Type of cooling
Types of construction
K11R / KPER / K12R
63 - 355
IP 54, IP 55, IP 56, IP 65 according to DIN VDE 0530-5: 1988
IC 411 according to DIN EN 60034-6: 1996
IM B3, IM B35, IM B5 and derived types of construction according to DIN EN 60034-7: 1996
When mounting motors with vertical shaft position, there is to be prevented the ingress of foreign bodies into the vent holes.
Design for potentially explosive atmospheres according to apparatus group II, category 2 acc. to
DIN EN 50 014:1994 (DIN VDE 0170/0171 part 1) General Provisions
DIN EN 50 019:1996 (DIN VDE 0170/0171 part 6) Increased Safety „e“
Temperature class T1 to T3
Fixing dimensions and coordination between output and dimensions according to DIN 42673 page 2 or DIN 42677 page 2
Ambient temperatures -40°C to +40°C
The construction of the motors is tested through the Physikalisch-Technische Bundesanstalt (PTB) Braunschweig and approved with the following
partial certificates:
Partial certificate PTB no. Ex-95.D.3020 U with the respective supplements
Partial certificate PTB no. Ex-95.D.3162 U with the respective supplement
Partial certificate PTB no. Ex-95.D.3021 U with the respective supplements
Partial certificate PTB no. Ex-93.C.3059 U with the respective supplements
Partial certificate PTB no. Ex-90.C.3152 U with the respective supplements.
Furthermore, the series are tested through the Schweizerischer Elektrotechnischer Verein
certificate A. no. 97.1 10387.01
and approved through the Schweizer Eidgenössische Starkstrominspektorat (Swiss Confederate Power Current Inspectorate)
approval no. 98.5 51477.01, 95.1 11107.07.
The reports on the test for intended use in hazardous areas are available. The certificates of conformity and the EC certificates of sample test
issued for the individual types are to be taken from the approval summary.
Squirrel-cage motors, flame-proof enclosure type of protection EEx de/d
Series
Sizes
Degrees of protection
Type of cooling
Types of construction
K81R / K82R
56 - 355
IP 54, IP 55, IP 56 according to DIN VDE 0530-5: 1988
IC 411 according to DIN EN 60034-6: 1996
IM B3, IM B35, IM B5 and derived types of construction according to DIN EN 60034-7: 1996
When mounting motors with vertical shaft position, there is to be prevented the ingress of foreign bodies into the vent holes.
Design for potentially explosive atmospheres according to apparatus group II, category 2 acc. to
DIN EN 50 014:1994 (DIN VDE 0170/0171 part 1) General Provisions
DIN EN 50 018:1994 (DIN VDE 0170/0171 part 5) Flame Proof Enclosure Type of Protection „d“
Temperature class T3 to T6
Fixing dimensions and coordination between output and dimensions according to DIN 42673 page 3 or DIN 42677 page 3
Ambient temperatures -20°C to +60°C
The construction of the motors is tested through the Physikalisch-Technische Bundesanstalt (PTB) Braunschweig and approved with the following
EC certificates of sample test:
Partial certificate PTB no. PTB 99 ATEX 1098, EExdIICT3 - T6, EEx de T3 - T6
Squirrel-cage motors, type of protection „n“ according to IEC report 79-15 (1987)
Series
Size
Degrees of protection
Type of cooling
K11R / KPER / K12R
63 - 355
IP 54, IP 55, IP 56, IP 65 according to DIN VDE 0530-5: 1988
IC 411 according to DIN EN 60034-6: 1996
1
Fixing dimensions and coordination between output and dimensions according to DIN 42673 page 1 or DIN 42677 page 1
Types of construction IM B3, IM B35, IM B5 and derived types of construction according to DIN EN 60034-7: 1996
When mounting motors with vertical shaft position, there is to be prevented the ingress of foreign bodies into the vent holes.
Design for potentially explosive atmospheres according to apparatus group II, category 3 acc. to IEC report 79-15 (1987)
Temperature class T3 or T4
Ambient temperatures -40°C to +55°C
For K11R are available the EC certificates of sample test IBExU994TEX 1094 and 1095, for KPER are available the EC certificates of sample test
PTB no. Ex-.96.Y.3725U, EX-96.Y.3726.
Furthermore, the series are tested through the Schweizerischer Elektrotechnischer Verein and approved through the Schweizer Eidgenössisches
Starkstrominspektorat (Swiss Confederate Power Current Inspectorate)
Certificate A. no. 95.1 11108.03
Approval no. 95.1 11108.04.
Squirrel-cage motors for being used in case of potentially inflammable dusts (zone 21, 22)
Design for zone 21
Series
Sizes
Degree of protection
Type of cooling
Types of construction
KPER / K11Q
56 - 280 (315 in preparation)
IP 65 according to DIN VDE 0530-5: 1988
IC 411 according to DIN EN 60034-6: 1996
IM B3, IM B35, IM B5 and derived types of construction according to DIN EN 60034-7: 1996
When mounting motors with vertical shaft position, there is to be prevented the ingress of foreign bodies into the vent holes.
Design for potentially explosive atmospheres according to apparatus group II, category 2 acc. to DIN EN 50281-1-1 and -2
Fixing dimensions and coordination between output and dimensions according to DIN 42673 page 1 or DIN 42677 page 1
Ambient temperatures -40°C to +40°C
The design of the motors has been tested by the DMT (Deutsche Montan Technik), certified with the certificate
DMT 00 ATEX E 002 X for the sizes 132 to 280
DMT 00 ATEX E 012 X for the sizes 56 to 132 T
and approved in the respective test report.
Design for zone 22
Series
Sizes
Degrees of protection
Type of cooling
Types of construction
K21R / K11R
56 - 355
IP 55 according to DIN VDE 0530-5: 1988
IC 411 according to DIN EN 60034-6: 1996
IM B3, IM B35, IM B5 and derived types of construction according to DIN EN 60034-7: 1996
When mounting motors with vertical shaft position, there is to be prevented the ingress of foreign bodies into the vent holes.
Design for potentially explosive atmospheres according to apparatus group II, category 3 acc. to E DIN EN 50281-1-1 and -2
Fixing dimensions and coordination between output and dimensions according to DIN 42673 page 1 or DIN 42677 page 1
Ambient temperatures -40°C to +40°C
The design of the motors has been certified with manufacturer’s declaration of incorporation.
EC certificates of conformity and EC certificates of prototype test
2
3
4
Standards and specifications
The motors correspond to the appropriate standards, in particular to the following::
Title
DIN/VDE
IEC
General regulations
for electrical rotating machines
DIN EN 60034-1/02.99
IEC 34-1
IEC 85
Fixing dimensions and coordination between
output and dimensions at IM B3
DIN 42673
(IEC 72)
Fixing dimensions and coordination between output
and dimensions at IM B5, IM B35 and IM B14
DIN 42677
(IEC 72)
Rotating electrical machines, terminal markings and direction of rotation
DIN VDE 0530 part 8
IEC 34-8
Rotating electrical machines, symbols
for types of construction and mounting
DIN EN 60034-7
IEC 34-7
Rotating electrical machines, built-in thermal protection
-
IEC 34-11
Rotating electrical machines, methods of cooling
DIN EN 60034-6
IEC 34-6
Rotating electrical machines, classification
of degrees of protection
DIN VDE 0530 part 5
IEC 34-5
Rotating electrical machines, mechanical vibrations of
certain machines with shaft heights 56 mm and higher
DIN EN 60034-14
IEC 34-14
Cylindrical shaft ends for rotating electrical machines
DIN 748 part 3
IEC 72
Rotating electrical machines, noise limits
DIN EN 60034-9
IEC 34-9
Rotating electrical machines, starting performance of single-speed
three-phase cage induction motors for voltages up to 660 V, 50 cps
DIN EN 60034-12
IEC 34-12
IEC-standard voltages
DIN IEC 38
IEC 38
General regulations
DIN EN 50014/VDE 0170/0171 T.1
IEC 79-0
Increased safety „e“
DIN EN 50019/VDE 0170/0171 T.6
IEC 79-7
Flameproof enclosure „d“
DIN EN 50018 / VDE 0170/0171 T.5
-
Electrical apparatus for being used in areas
with potentially inflammable dusts
DIN EN 50281-1-1
-
For EEx-motors are valid furthermore
Furthermore, VEM motors comply with various foreign regulations which have been adapted to the IEC-publ. 34-1 and they are available
according to the regulations of the Classification Authorities
Germanischer Lloyd
Bureau Veritas
Lloyd’s Register of Shipping
American Bureau of Shipping
Det Norske Veritas
Russian Register.
For these standards and specifications are valid the following admissible limits of temperature rise:
Specifications
Coolant temperature
Admissible limit of temperature rise in K
(measuring acc. to resistance method)
Insulation class
E
B
°C
A
F
DIN VDE 60034-1/02.99
40
60
75
80
105
IEC 34-1
40
60
75
80
105
Switzerland SEV
40
60
75
80
105
Germanischer Lloyd
45
55
70
75
95
American Bureau of Shipping
50
55
65
75
95
Bureau Veritas
50
50
65
70
90
Det Norske Veritas
45
50
65
70
Lloyd’s Register
45
50
65
70
90
40/45
60
75
85
110
Russ. Register
1)
90
1)
only with special approval
5
Tolerances
Following tolerances are admitted according to DIN EN 60034-1/02.99. These tolerances are permissible for the values assured for three-phase asynchronous motors, taking the necessary manufacturing tolerances and material variations of the used raw materials into account. The standard contains the following notes to that:
1. A guarantee for all or any of the values shown in the table ist not mandatory. In tenders, the guaranteed values for which permissible deviations
should apply must be expressly specified. The permissible variations must correspond to those stated in the table.
2. There is pointed to the distinctions concerning the definition „Guarantee“. In some countries, distinction is drawn between guaranteed values and
typical or declared values.
3. If the permissible deviation applies only in one direction, then the value in other direction is not limited.
Tolerances of the design values
Efficiency (with indirect calculation)
Power faktor
Slip
(at rated-load operating temperature)
Starting current
(in the planned starting circuit)
Starting torque
Pull-up torque
Pull-out torque
Moment of inertia
Noise intensity (measurement area sound pressure level)
-0,15 (1-h) up to PN ≤ 50 kW
-0,1 (1-η) up to PN > 50 kW
1-cosϕ at least 0,02
6
at most 0,07
+ 20 % up to PN ≥ 1kW
+ 30 % up to PN < 1kW
+ 20 %
without limiting downwards
- 15 % and + 25 %
- 15 %
- 10 % (with the application of this tolerance MK/M at least. 1,6)
+ 10 %
+ 3 dB (A)
Tolerances of the fixing dimensions
Dimensional
short sign according to DIN
6
Meaning of the dimension
Fit or tolerance
a
Spacing of housing foot fixing holes in axial direction
+ 1 mm
b
Spacing of housing foot fixing holes
across the axial direction
+ 1 mm
e1
Pitch circle diameter of the attachment flange
+ 0,8 mm
a1
Diameter or width across corner of the flange
+1%
g
f
Largest width of the motor
(without terminal box)
+2%
k
k1
Overall length of the motor
+1%
p
Overall height
(lower edge foot, housing or flange up to highest point of the motor)
+2%
s
s1
Diameter of the fixing holes of the foot or of the flange
+3%
w1
w2
Centre of the first fixing hole up to shaft end shoulder
+ 3 mm
b1
Diameter of the centering shoulder of the attachment flange
up to 230 j6
from 250 h6
d
d1
Diameter of the shaft end
up to Ø 48 k6
from Ø 55 m6
h
Shaft height (lower edge foot up to centre of shaft end)
up to 250-0,5
higher than 250-1
u
u1
Width of the key
h9
t
t1
Lower edge of shaft end up to upper edge of key
+ 0,2 mm
Motor weight
- 5 bis + 10 %
Mechanical design
Types of construction
Basic types of construction can be used in all derived types of construction.
Exceptions:
1)
On inquiry
2)
Only available in the types of construction 56 - 160
3)
This type of construction is to be ordered directly because of additional water return hole in the flange end shield
7
Shaft ends
As specified in IEC 34-7, the definition of the motor ends is as follows :
D-end (DS): Drive end of the motor (Driving side)
N-end (NS): Non-driving end (opposite end to the drive end) (Non-driving side)
The motors are always supplied with the key fitted. The second shaft end can transmit the full nominal output with coupling service. The power transmission capability at belt service, chain service or pinion service for the second shaft end is available on request.
Degrees of protection
Degrees of protection for electrical machines are indicated according to DIN VDE 0530 part 5 through the identification marking „IP“ and two characteristic numerals for the degree of protection. The first characteristic numeral specifies the protection against damaging ingress of dust and foreign particles and against contact with inner moving or live parts, the second characteristic numeral specifies the protection against the penetration
of water having an effect on the machine from different directions and with different intensities.
The respective degrees of protection of the various series of motors are to be taken from the tables of the electrical selection data.
Sense of rotation
When connecting a VEM motor with the stator terminals U, V, W to a three-phase mains with the phase sequence L1, L2 and L3, the direction of rotation of the motor goes clockwise as seen on the D-end. In case of required alteration of the direction of rotation, two terminals are to be exchanged.
Bearing arrangement / bearing lubrication
VEM motors are equipped with antifriction bearings of well-known manufacturers. The bearings have a nominal service life of at least 20.000 hours
for maximum permissible load conditions. For motors without additional axial loading, the nominal service life is 40.000 hours for coupling service.
The sizes 56 - 160 are equipped with life-lubricated bearings. For motors from size 180, depending on the useful life of grease, bearings must be
relubricated in good time so that the nominal bearing service life is reached. Under normal operating conditions, the grease packing will last for
10.000 hours of operation with 2-pole version and for 20.000 hours of operation with versions from 4 poles upwards without being renewed. For
motors fitted with relubricating facility and working under normal operating conditions, the grease will last for 2.000 hours of operation or for 4.000
hours of operation. The standard grease is a KE2R-40 type according to DIN 51825.
Use of cylindrical roller bearings
Using cylindrical roller bearings („heavy bearing arrangement“), relatively high radial forces or masses can be supported at the motor shaft end.
Examples : belt drives, pinions or heavy couplings. The minimum radial force at the shaft end must be a quarter of the permissible radial force.
Account must be taken of permissible shaft end loading.
Important to note: Radial forces below the minimum value can lead to bearing damages within a few hours. Test runs in no-load state are only
permissible for a short period.
If the specified minimum radial forces cannot be met, we recommend to use grooved ball bearings („easy bearing arrangement“). Bearing change
is possible on request.
Transport locking
According to the specific conditions of transport, motors with cylindrical roller bearing can be provided, according to DIN 5412, with a transport locking
on the driving end as protection against transport shocks.
Vibration characteristics
The admissible vibration intensities of electric motors are specified in DIN EN 60034-14.
The vibration intensity stage N (normal) is achieved or is below limit by VEM motors in the basic version. On demand, the vibration intensity stages
R (reduced) and S (special) can be delivered in dependence on the type at extra charge.
The following values are recommended according to DIN EN 60034-14:
Vibration intensity
Speed range
Limit values of vibration velocity (mm/s)
stages
rpm
in frequency range 10 to 1000 cps for sizes
56 - 132
160 - 225
250 - 450
8
N
(normal)
600-3600
1,8
2,8
3,5
R
(reduced)
600-1800
up to 1800-3600
0,71
1,12
1,12
1,8
1,8
2,8
S
(special)
600-1800
up to 1800-3600
0,45
0,71
0,71
1,12
1,12
1,8
All rotors are dynamically balanced with half key inserted. This balancing is documented on the rating plate with the letter H after the motor number.
On inquiry, the balancing is possible with the complete key; this balancing is documented with the letter F after the motor number.
Noise characteristics
The noise measurement is carried out according to DIN EN 23741/23742 at design output, design voltage and design frequency. In accordance with
DIN EN 60034-9, the spatial mean value of the measurement area sound pressure level LpA measured at a distance of 1 m from the machine outline is stated as noise intensity in dB (A).
The tabular value + 5 dB (A) applies as an approximate value for motors in 60 cps design. Binding data for 60 cps are available on request. For the
main type series, the noise values are specified in the main catalogue in form of tables. In case of special versions, please refer to the manufacturer.
Cooling and ventilation
The motors are equipped with radial fans which cool the motor, whatever is the direction of rotation (IC 411 according to DIN EN 60034-6). When
installing the motors, care should be taken that a minmum distance from the fan cover to the wall (dimension B) is maintained.
Paint finish
Normal finish
Adapted for group of climates „moderate“ according to IEC 721-2-1,
• weatherprotected and non-weatherprotected locations, short time up to 100 % of relative air humidity at temperatures up to + 30 °C,
continuously up to 85 % of relative air humidity at up to + 25 °C.
Finish system Sizes 56 - 112
All components except aluminium terminal boxes : prime plastic paint, layer thickness approx. 30µm
Finish coat water-soluble varnish with layer thicknesses from 30 µm to 60 µm
Sizes 132 - 355
Synthetic-resin zincphosphate primary coat, layer thickness approx. 30 µm
Finish coat : two-component polyurethane, layer thickness approx. 30 µm
Special finish
Adapted for group of climates „World-wide“ according to IEC 721-2-1
• Non-weather-protected location in corrosive chemical and sea atmosphere, short time up to 100 % of relative air humidity at temperatures
up to + 35 °C, continuously up to 98 % of relative air humidity with temperatures up to + 30 °C
Finish system
Sizes 56 - 112
All components with prime plastic paint, layer thicknesses: approx. 30 µm
Finish coat water-soluble varnish with layer thicknesses from 60 µm to 90 µm
Two-component coating varnish on demand
BG 132 - 355
Synthetic-resin zincphosphate primary coat, layer thickness approx. 30 µm
Intermediate coat on two-component base, layer thickness approx. 30 µm
Finish coat: two-component coating varnish on demand
Standard colour
RAL 7031 blue-grey
Further special coating systems:
Version for excessive thermal stresses
Version for excessive chemical and radiation stresses
Special finish upon customer’s request
Design voltage and frequency
In the basic version, the motors are supplied for following design voltages:
230/400 V ∆/Y 50 cps
400/690 V ∆/Y 50 cps
690 V ∆
480 V ∆
50 cps
60 cps
The motors can run without changing the nominal output in mains, in which the voltage at nominal frequency deviates from the nomianl value up to
± 5 % (design voltage range A). The above mentioned standard voltages according to DIN IEC 38 are taken as design point. Application for voltage range is possible, limits see tables of the electrical selection data.
Special voltages and frequencies upon customer’s request.
Design torque
The nominal torque in Nm given at the motor shaft is calculated by
M = 9550 x P
n
with P = nominal output in kW
n = speed in rpm
9
If the voltages deviate from their nominal value (within the admissible limits), starting torque, pull-up torque and pull-out torque change about quadratically and the starting current changes about linearly with the voltage variation.
Design output
The nominal output applies for continuous operation as specified in DIN EN 60034-1/02.99 at a coolant temperature of 40 °C and a site altitude of
≤ 1000 m above M.S.L. On account of the thermal reserve, the nominal output can be maintained up to 50 °C coolant temperature or up to 2.500 m
site altitude. These conditions can only be applied alternatively. The output must be reduced in case of coupling. In case of motors in design for seagoing vessels, the output is possibly reduced according to the Classification Rules.
Additional thermal winding protection
The additional thermal winding protection is exclusively provided as additional protective device for monitoring the temperature of the stator winding and is not regarded as protective device according to VDE 0170/0171 part 6 / DIN EN 50019 appendix A.
Overload capacity
In compliance with DIN EN 60034-1, all motors can be exposed to the following overload conditions:
- 1,5 times the rated current for 2 min.
- 1,6 times the rated torque for 15 s
Both conditions apply to design voltage and design frequency.
Design efficiency and design power factor
The efficiency η and the power factor cos ϕ are stated in the Motor Selection Data lists. Partial load ratings on demand.
Re-starting with residual field and phase opposition
A re-starting after mains failure against 100 % residual field is possible for all motors.
Project planning and application instructions
Hazardous areas
Which zones in the open or in closed areas are to be considered hazardous within the relevant rules or regulations is to be leaved exclusively to the
user or, in case of doubt about the definition of harzardous areas, to the competent inspectorate.
Electrical motors for potentially explosive atmospheres correspond to the standards of the series DIN EN 60034 (VDE 0530) as well as DIN EN 5001450020, DIN EN 50281-1-1. In hazardous areas they can only be placed in accordance with the competent inspectorate being responsible for the
assignment of potentially explosive atmospheres (zonal classification). The type of protection, the temperature class as well as special requirements
are indicated on the rating plate or in the certificate of conformity.
Apparatus group I, category M2
Under this category come electrical machines of increased-safety types protections, of flameproof enclosure types of protection, of pressurized enclosure types of protection for being used in the mining area.
Apparatus group II, category 2 (up to now zone 1)
Under this category come electrical machines of increased-safety types protections, of flameproof enclosure types of protection, of pressurized enclosure types of protection for being used in the other areas endangered through an explosive atmosphere.
Apparatus group II, category 3 (up to now zone 2)
Under this category come electrical machines of the type of protection „Ex n“.
If the certificate number is completed by the letter X, special requirements in the certificate of conformity are to be observed.
The operation at the converter must be certified specially. The special manufacturer’s instructions are to be observed absolutely. For the type of protection EEx e, motor, converter and protective device must be marked as components belonging together and the admissible operating data must
be determined in the common test certificate (VDE 0165).
Through the interconnecting cable installed between converter and electrical machine, the voltage peaks generated by the converter can be badly
influenced in their magnitude. In the system converter - cable - electrical machine, the maximum value of the voltage peaks at the terminals of the
machine must never exceed the value indicated in the special manufacturer’s instructions.
10
Installation and electric connection
The erection of electrical installations in potentially explosive atmospheres requires in Germany the observance of the following regulations:
- DIN VDE 0118
- ElBergV
- DIN 56 165/VDE 0165/DIN EN 60079-14
-VbF
„Erection of Electrical Installations in Mines“.
„Elektrobergverordnung“
(Ordinance Regulating the Electrical Installations in Mines).
„Installation of Electrical Apparatus in Hazardous Areas.
„Verordnung über brennbare Flüssigkeiten“
(Ordinance Concerning Flammable Liquids)
Abroad are to be followed the corresponding national regulations.
The general safety and commissioning instructions are valid for the electric connection. The cable entries must be approved for the explosion-proof
area and they must be protected against selfloosening. Non-used apertures are to be closed with accepted plugs.
Protective measures against excessive temperature rise
If the test certificate or the rating plate do not contain different data concerning duty type and tolerances, the electrical machines are designed for
continuous duty and for normal starts, not recuring frequently, in the course of which the temperatures are not rising essentially. The motors can only
be used for that duty being indicated on the rating plate.
The range A in DIN EN 60034-1 (VDE 0530, part 1) - voltage ± 5 %, frequency ± 2 %, waveform, supply balance - is to be observed so that the temperature rises within the admissible limits. Greater deviations from the design values can cause an excessive temperature rise of the electric machine and must be indicated on the rating plate.
Each machine is to be protected in all phases against excessive temperature rise by means of an inverse time-delay circuit breaker with phase-failure protection according to VDE 0660 or an equivalent device. The protective device is to be set to the design current. In case of windings in delta
connection, the trip elements are connected in series with phase windings and set to 0,58 times the design current. When being impossible this
connection, additional protective measures are necessary (eg. thermal machine protection).
In contrast to the degree of protection „Ex-n“, in case of the „increased safety“ the start will be monitored too. Therefore, in case of locked rotor, the
protective device must disconnect within the tE-time indicated for the corresponding temperature class. The requirement is fulfilled if the tripping time
- it is to be taken from the tripping characteristic (initial temperature of 20 °C) for the ratio IA/IN - doesn’t exceed the indicated tE-time.
In compliance with the data of the certificate of conformity, electrical machines for heavy starting (acceleration time > 1,7 x tE-time) are to be protected through a starting-cycle monitoring circuit.
Thermal machine protection through direct temperature monitoring of the winding is admissible if that is certified and indicated on the rating plate. It
is consisting of temperature sensors according to DIN 44081 / 44082 which in connection with tripping units, provided with the mark of conformity
of an authorized testing agency, are guaranteeing the explosion-protection.
In case of pole-changing motors, seperate interlocked protective devices are necessary for each speed step. We recommend devices provided with
the test report of an authorized testing agency.
Maintenance and repair
In Germany, maintenance, repair and modifications at explosion protected machines are to be carried out observing the ElexV/ElBergV, the safety
instructions und descriptions of the general maintenance instructions.
Work, influencing the explosion protection, such as eg.:
- repair work at the stator or rotor winding and at the terminals,
- repair work at the ventilation system,
- the disassembly of explosion-proof machines,
are to be carried out at the manufacturer or through a workshop specialized for electrical machines.
The work is to be marked by an additional repair name plate with the following data:
- date
- operative firm
- if necessary, mode of repair
- if necessary, sign of the expert.
If the work will not be realized by part of the manufacturer, it is to be accepted by an officially recognized expert who has to issue a written confirmation or to provide the machine with his mark of conformity. Abroad are to be observed the corresponding national regulations.
Spare parts
There may only be used original spare parts (see list of spare parts), excepting standardized, commercial and equivalent parts (eg. antifriction bearings); in particular, this applies to seals and connecting pieces too.
11
Motor selection data
Design point 400 V, 50 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
η
cos ϕ
IA/IN
-
I
400 V
A
rpm
%
61,0
65,0
67,0
73,0
74,0
77,0
78,0
83,0
82,0
85,0
87,0
87,5
89,0
89,5
90,0
87,5
87,5
89,5
88,0
90,0
89,5
91,0
90,5
91,5
90,5
93,0
91,5
93,0
93,0
93,2
93,0
93,7
94,0
94,1
94,5
95,0
94,5
95,3
95,0
95,0
0,80
0,74
0,84
0,79
0,84
0,82
0,88
0,86
0,87
0,82
0,87
0,88
0,86
0,92
0,93
0,90
0,90
0,90
0,90
0,91
0,91
0,92
0,92
0,92
0,93
0,90
0,90
0,91
0,91
0,93
0,92
0,88
0,89
0,88
0,90
0,90
0,89
0,90
0,89
0,92
0,53
0,75
0,97
1,43
1,76
2,60
2,75
3,85
5,20
6,90
8,10
8,6
10,4
9,6
11,6
13,7
17,4
17,9
23,5
22,0
28,5
26,0
33,0
34,0
43,0
41,0
54,0
47,5
65
60
79
82
117
101
130
116
162
134
191
182
3,7
4,1
4,1
4,8
5,3
5,6
6,5
7,4
6,8
7,7
7,9
7,0
8,5
7,4
6,2
6,9
5,4
6,5
5,0
7,3
5,6
7,0
5,4
6,6
5,2
7,0
5,3
7,6
5,4
7,2
5,4
7,1
7,8
7,1
6,6
7,5
5,8
7,5
7,5
7,3
Data
on inquiry
MA/MN MS/MN MK/MN
tE-time
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 3000 rpm - 2-pole design
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
K11R
K11R
K12R
63 K2
63 G2
71 K2
71 G2
80 K2
80 G2
90 S2
90 L2
100 L2
112 M2
112 MX2
132 S2
132 SX2
132 SX2
K11R
160 M2
K11R
160 MX2
K11R
160 L2
K11R
180 M2
K11R
200 L2
K11R
200 LX2
K11R
225 M2
K11R
250 M2
K11R
280 S2
K11R
280 M2
K11R
315 S2
K11R
315 M2
K11R
315 MY2
K11R
315 L2
K11R
315 LX2
K12R
355 M2
K12R
355 MX2
K12R
355 L2
0,18
0,25
0,37
0,55
0,75
1,10
1,30
1,85
2,50
3,30
4,10
4,6
5,5
5,5
6,6
7,5
9,5
10,0
13,0
12,5
16,0
15
19
20
25
24
31
28
38
36
47
47
68
58
76
68
95
80
112
110
135
125
165
150
200
190
255
220
300
250
335
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1-T3
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
2870
2800
2740
2770
2810
2830
2850
2870
2870
2910
2910
2900
2925
2930
2910
2945
2917
2935
2900
2945
2920
2945
2920
2935
2910
2950
2925
2970
2950
2970
2955
2970
2975
2975
2970
2975
2960
2975
2960
2970
1,6
1,9
1,7
2,2
1,9
2,5
2,4
3,0
2,5
2,3
2,5
1,4
1,9
2,1
1,7
1,9
1,5
1,8
1,4
1,8
1,4
1,8
1,5
1,8
1,4
1,6
1,4
1,5
1,2
1,9
1,4
1,4
1,4
1,4
1,1
1,8
1,4
1,8
1,2
1,5
1,6
1,9
1,7
2,2
1,9
2,3
2,0
3,0
2,4
2,1
1,9
1,2
1,3
1,3
1,1
1,6
1,3
1,5
1,1
1,4
1,1
1,5
1,3
1,3
1,2
1,2
1,2
1,0
0,9
1,5
1,1
1,3
1,3
1,3
1,0
1,6
1,3
1,6
1,2
1,3
2,0
2,2
2,2
2,5
2,4
2,5
2,6
3,2
2,7
3,1
3,3
2,8
3,3
2,6
2,1
2,7
2,1
2,5
1,9
2,8
2,2
2,6
2,1
2,4
1,9
2,5
2,2
2,6
2,0
2,6
1,9
2,2
2,3
2,1
1,7
2,3
1,8
2,2
2,1
3,0
Other voltages and frequencies on inquiry. Modifications of motors not yet certified by the PTB are possible!
12
29
13
16
11
14
8
14
9
13
11
11
13
6
18
12
30
15
18
13
16
10
16
12
16
16
18
29
16
35
30
40
40
30
20
24
20
35
26
27
17
26
16
30
27
40
35
50
23
40
30
28
18
29
11
26
21
13
11
16
10
10
15
19
25
18
13
11
0,00013
0,00015
0,00025
0,00032
0,00057
0,00072
0,00132
0,00170
0,00275
0,0045
0,0055
0,0110
0,0110
0,0258
0,0258
0,0575
0,0575
0,0575
0,0575
0,0675
0,0675
0,105
0,105
0,128
0,128
0,193
0,193
0,375
0,375
0,650
0,650
1,21
1,21
1,44
1,44
1,44
1,44
1,76
1,76
2,82
2,82
3,66
3,66
4,43
4,43
4,20
4,20
5,50
5,50
9,50
9,50
4,9
5,2
6,7
7,6
10,7
11,5
16
19
25
32
38
57
57
88
88
120
120
120
120
138
138
175
175
210
210
255
255
360
360
490
490
730
730
815
815
850
850
970
970
1150
1150
1460
1460
1630
1630
2000
2000
2200
2200
2400
2400
Motor selection data
Design point 400 V, 50 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
η
cos ϕ
IA/IN
-
I
400 V
A
rpm
%
MA/MN MS/MN MK/MN
tE-time
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 1500 rpm - 4-pole design
KPER
KPER
63 K41)
63 G4
0,12
0,18
T1-T3
T1-T3
1370
1360
54,0
60,0
0,68
0,69
0,48
0,63
2,9
3,2
1,8
1,9
1,8
1,9
2,2
2,2
50
30
70
35
0,00019
0,00024
4,8
5,2
KPER
KPER
71 K4
71 G4
0,25
0,37
T1-T3
T1-T3
1380
1370
65,0
67,0
0,73
0,75
0,79
1,08
3,4
3,6
1,4
1,6
1,4
1,6
1,8
2,0
24
18
27
21
0,00040
0,00050
6,8
7,8
KPER
KPER
80 K4
80 G4
0,55
0,75
T1-T3
T1-T3
1380
1390
69,0
72,0
0,76
0,74
1,59
2,00
3,9
4,4
1,8
2,0
1,8
2,0
2,0
2,3
13
14
16
17
0,00087
0,00107
10,6
11,7
KPER
KPER
90 S4
90 L4
1,00
1,35
T1-T3
T1-T3
1410
1410
77,0
79,0
0,80
0,81
2,40
3,10
5,1
5,5
2,4
2,3
2,3
1,8
2,5
2,5
17
12
19
14
0,00207
0,00260
15,5
18
KPER
KPER
100 L4
100 LX4
2,0
2,5
T1-T3
T1-T3
1420
1440
80,0
83,0
0,80
0,78
4,65
5,6
6,0
6,7
2,8
2,3
2,6
2,2
2,9
2,9
11
11
13
12
0,00400
0,00725
23,5
30
KPER
112 M4
3,6
T1-T3
1440
85,0
0,77
8,1
7,0
2,8
2,1
2,9
7
9
0,0090
37
K11R
K11R
132 S4
132 M4
5,0
6,8
T1-T3
T1-T3
1435
1455
84,5
87,5
0,83
0,82
10,2
13,6
6,5
6,1
2,0
2,1
1,6
1,8
2,8
2,7
10
12
15
29
0,0150
0,0280
53
72
K11R
K11R
160 M4
160 L4
10,0
13,5
T1-T3
T1-T3
1465
1470
91,0
90,5
0,89
0,86
18,0
25,0
6,3
7,7
2,0
2,5
1,7
2,0
2,5
3,0
18
9
40
26
0,0780
0,0900
123
136
K11R
180 M4
180 L4
T1-T3
T1,T2
T1-T3
T1,T2
1475
1465
1475
1470
90,5
90,5
90,5
90,5
0,87
0,88
0,85
0,86
27,5
31,0
33
37
6,8
6,0
7,1
6,3
1,9
1,7
2,1
1,8
1,6
1,4
1,8
1,6
2,5
2,3
2,8
2,4
15
K11R
15,0
17,0
17,5
20,0
45
35
25
24
0,1380
0,1380
0,1380
0,1380
180
180
185
185
K11R
200 L4
24
27
T1-T3
T1,T2
1477
1470
92,7
92,5
0,87
0,88
43
48
6,8
6,0
1,8
1,6
1,5
1,5
2,4
2,2
12
35
30
0,2750
0,2750
270
270
K11R
225 S4
225 M4
T1-T3
T1,T2
T1-T3
T1,T2
1475
1472
1480
1475
93,0
92,9
94,0
93,5
0,85
0,85
0,85
0,85
55
60
65
73
6,1
5,6
7,4
6,6
1,6
1,5
2,2
2,0
1,4
1,2
1,7
1,6
1,9
1,7
2,3
2,1
14
K11R
30
33
36
40
30
30
22
19
0,525
0,525
0,525
0,525
380
380
385
385
K11R
250 M4
44
50
T1-T3
T1,T2
1485
1480
94,0
94,0
0,86
0,86
79
90
7,2
6,3
1,8
1,7
1,6
1,5
2,1
1,9
10
30
27
0,950
0,950
530
530
K11R
280 S4
280 M4
T1-T3
T1,T2
T1-T3
T1,T2
1485
1480
1485
1483
94,2
94,0
95,0
94,5
0,84
0,85
0,84
0,84
106
124
127
147
7,2
6,1
7,5
6,5
1,8
1,5
2,0
1,7
1,6
1,4
1,8
1,6
2,2
1,8
2,4
2,0
13
K11R
58
68
70
80
40
30
35
30
1,96
1,96
2,27
2,27
765
765
840
840
K11R
315 S4
315 MY4
95,0
94,5
95,0
94,7
95,4
0,84
0,84
0,84
0,85
0,85
152
181
181
216
205
7,2
6,5
6,8
5,6
7,1
2,0
1,6
1,8
1,3
1,5
1,8
1,4
1,7
1,1
1,4
2,2
2,0
2,2
1,6
2,4
10
K11R
1485
1470
1485
1478
1489
25
315 M4
14
30
30
35
K11R
315 L4
1491
96,0
0,86
236
7,6
1,4
1,3
2,4
18
40
K11R
315 LX4
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
9
K11R
84
100
100
120
115
135
135
165
170
200
2,27
2,27
2,73
2,73
4,82
4,82
5,93
5,93
6,82
6,82
875
875
1000
1000
1200
1200
1450
1450
1630
1630
K12R
355 M4
K12R
355 MX4
K12R
355 L4
215
245
240
275
275
315
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
5,60
5,60
7,90
7,90
9,50
9,50
1950
1950
2150
2150
2400
2400
Data on inquiry
9
7
13
Other voltages and frequencies on inquiry.
1) only available up to 380 V
Modifications of motors not yet certified by the PTB are possible!
13
Motor selection data
Design point 400 V, 50 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
η
cos ϕ
IA/IN
-
I
400 V
A
rpm
%
MA/MN MS/MN MK/MN
tE-time
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 1000 rpm - 6-pole design
KPER
KPER
80 K6
80 G6
0,37
0,55
T1-T3
T1-T3
920
910
62,0
66,0
0,70
0,69
1,30
1,75
3,2
3,6
2,0
2,1
1,8
2,1
2,0
2,2
26
22
28
26
0,00130
0,00175
11
12,5
KPER
KPER
90 S6
90 L6
0,65
0,95
T1-T3
T1-T3
925
925
69,0
71,0
0,71
0,71
1,95
2,70
3,4
3,9
1,8
2,1
1,7
2,0
1,9
2,2
30
23
35
27
0,00325
0,00425
16
19
KPER
100 L6
1,4
T1-T3
940
75,0
0,73
3,75
4,2
2,1
2,0
2,3
20
24
0,00625
24
KPER
112 M6
1,9
T1-T3
950
79,0
0,74
4,7
5,3
2,2
2,0
2,4
18
21
0,01225
33,5
K11R
K11R
K11R
132 S6
132 M6
132 MX6
2,6
3,5
4,8
T1-T3
T1-T3
T1-T3
950
960
963
80,5
82,9
83,5
0,79
0,82
0,83
5,9
7,4
10,0
5,3
6,3
5,1
1,8
2,0
1,8
1,8
2,0
1,6
2,8
3,0
2,5
19
21
28
22
24
30
0,018
0,023
0,043
49
53
70
K11R
K11R
160 M6
160 L6
6,6
9,7
T1-T3
T1-T3
965
970
84,5
85,0
0,84
0,84
13,4
19,6
5,4
5,8
1,9
2,2
1,6
1,9
2,5
2,7
30
13
35
30
0,053
0,113
89
123
K11R
180 L6
13,2
T1-T3
975
89,0
0,87
24,5
6,5
2,2
2,0
2,9
23
50
0,228
190
K11R
K11R
200 L6
200 LX6
16,5
20
T1-T3
T1-T3
977
977
87,5
90,5
0,82
0,90
33,0
35,5
6,8
6,4
2,4
2,2
2,1
1,6
3,2
2,5
9
18
28
45
0,228
0,443
190
265
K11R
225 M6
27
T1-T3
975
91,0
0,88
49,0
5,7
2,1
1,8
2,3
13
40
0,825
360
K11R
250 M6
33
T1-T3
985
92,0
0,86
60
6,0
2,1
1,7
2,4
12
35
1,28
475
K11R
K11R
280 S6
280 M6
40
46
50
T1-T3
T1-T3
T1,T2
990
990
990
93,9
94,0
94,0
0,86
0,88
0,88
71
80
87
7,0
7,5
6,7
1,9
1,9
1,9
1,8
1,6
1,7
2,5
2,5
2,4
24
25
55
60
2,63
3,33
3,33
715
810
810
K11R
315 S6
K11R
315 MY6
988
987
990
985
990
987
94,5
94,0
94,5
94,5
95,2
95,0
0,89
0,89
0,87
0,87
0,87
0,87
113
118
133
144
149
160
7,2
6,9
7,5
6,9
6,9
6,4
2,2
2,1
2,2
2,0
1,6
1,5
1,8
1,7
1,8
1,6
1,4
1,3
2,5
2,3
2,5
2,2
2,5
2,3
30
28
315 M6
15
40
35
K11R
315 L6
K11R
315 LX6
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
9
K11R
64
68
76
82
85
92
95
100
110
120
3,33
3,33
3,60
3,60
6,00
6,00
6,67
6,67
8,6
8,6
840
840
890
890
1080
1080
1250
1250
1460
1460
K12R
355 M6
K12R
355 MX6
K12R
355 L6
125
135
160
175
200
215
T1-T3
T1,T2
T1-T3
T1,T2
T1-T3
T1,T2
8,2
8,2
10,1
10,1
14
14
1650
1650
2100
2100
2400
2400
Other voltages and frequencies on inquiry.
Modifications of motors not yet certified by the PTB are possible!
14
Data on inquiry
Motor selection data
Design point 400 V, 50 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
η
cos ϕ
IA/IN
-
I
400 V
A
rpm
%
MA/MN MS/MN MK/MN
tE-time
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 750 rpm - 8-pole design
KPER
KPER
80 K8
80 G8
0,18
0,25
T1-T3
T1-T3
670
670
52,0
55,0
0,64
0,67
0,78
1,00
2,5
2,8
1,6
2,3
1,6
2,3
1,9
2,4
150
60
180
70
0,00130
0,00175
10,5
12
KPER
KPER
90 S8
90 L8
0,37
0,55
T1-T3
T1-T3
700
695
59,0
64,0
0,56
0,58
1,61
2,15
2,9
3,0
1,5
1,6
1,5
1,6
2,0
2,1
55
55
60
60
0,00300
0,00375
15
18
KPER
KPER
100 L8
100 LX8
0,65
0,95
T1-T3
T1-T3
700
705
66,0
74,0
0,63
0,68
2,25
2,75
2,9
4,1
1,5
2,0
1,5
2,0
1,8
2,5
60
60
70
70
0,00625
0,00900
23
28
KPER
112 M8
1,3
T1-T3
700
75,0
0,67
3,9
4,1
1,7
1,7
1,9
50
60
0,01225
33,5
K11R
K11R
132 S8
132 M8
1,9
2,6
T1-T3
T1-T3
700
705
75,0
78,5
0,75
0,74
4,9
6,5
3,9
4,5
1,6
1,8
1,6
1,7
2,2
2,6
30
29
35
30
0,018
0,023
49
57
K11R
K11R
K11R
160 M8
160 MX8
160 L8
3,5
4,8
6,6
T1-T3
T1-T3
T1-T3
720
720
730
80,0
81,5
84,0
0,72
0,74
0,73
8,7
11,6
15,6
4,3
4,5
5,0
1,8
1,9
2,1
1,7
1,8
1,9
2,4
2,4
2,7
40
40
35
45
50
40
0,043
0,053
0,113
80
90
122
K11R
K11R
180 L8
200 L8
9,7
13,2
T1-T3
T1-T3
725
730
85,0
86,5
0,73
0,72
22,5
30,5
5,1
5,6
2,3
2,3
2,0
2,1
2,6
2,9
12
13
40
40
0,145
0,228
140
195
K11R
K11R
225 S8
225 M8
16,5
20
T1-T3
T1-T3
730
735
88,5
90,5
0,81
0,81
33,5
39,5
6,0
5,3
2,2
2,0
1,9
1,7
2,8
2,2
20
25
50
60
0,440
0,825
275
360
K11R
250 M8
27
T1-T3
737
90,5
0,80
54
5,7
2,3
1,7
2,3
13
40
1,35
472
K11R
K11R
280 S8
280 M8
33
40
T1-T3
T1-T3
742
740
93,5
93,8
0,78
0,79
65
78
6,3
6,5
2,0
2,0
1,8
1,8
2,4
2,4
30
30
70
75
2,63
3,33
700
805
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
S8
M8
MY8
L8
LX8
50
68
80
95
115
T1-T3
T1-T3
T1-T3
T1-T3
T1-T3
740
740
740
94,0
94,0
94,0
0,80
0,80
0,80
96
131
153
5,9
6,3
5,7
1,7
2,1
1,6
1,6
1,9
1,5
2,1
2,6
2,2
18
9
50
35
3,33
3,60
6,00
6,76
8,71
850
880
1080
1250
1430
K12R
K12R
K12R
355 M8
355 MX8
355 L8
140
180
210
T1-T3
T1-T3
T1-T3
9,5
11,6
15,8
1600
2100
2400
Data on inquiry
Other voltages and frequencies on inquiry.
Modifications of motors not yet certified by the PTB are possible!
15
Motor selection data
Design point 480 V, 60 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 60 cps
Type
P
kW
Temperature
class
n
η
cos ϕ
IA/IN
-
I
480 V
A
rpm
%
MA/MN MS/MN MK/MN
tE-time
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 3600 rpm - 2-pole design
KPER
KPER
63 K2
63 G2
0,18
0,25
T1-T3
T1-T3
3380
3400
65,0
65,0
0,80
0,74
0,551)
0,751)
4,0
4,5
1,6
1,9
1,6
1,9
2,0
2,2
29
13
30
15
0,00013
0,00015
4,9
5,2
KPER
KPER
71 K2
71 G2
0,37
0,55
T1-T3
T1-T3
3340
3370
67,0
73,0
0,84
0,79
0,951)
1,441)
4,6
5,3
1,7
2,2
1,7
2,2
2,2
2,5
16
11
18
13
0,00025
0,00032
6,7
7,6
KPER
KPER
80 K2
80 G2
0,75
1,10
T1-T3
T1-T3
3410
3430
74,0
77,0
0,84
0,82
1,761)
2,601)
5,8
6,2
1,9
2,3
1,9
2,3
2,4
2,5
14
8
16
10
0,00057
0,00072
10,7
11,5
KPER
KPER
90 S2
90 L2
1,30
1,85
T1-T3
T1-T3
3440
3470
78,0
83,0
0,88
0,86
2,751)
3,851)
7,2
8,1
2,2
3,0
2,2
3,0
2,6
3,2
14
9
16
12
0,00132
0,00170
16
19
KPER
100 L2
2,50
T1-T3
3470
82,0
0,87
5,201)
7,5
2,4
2,4
2,7
13
16
0,00275
25
KPER
KPER
112 M2
112 MX2
3,3
4,1
T1-T3
T1-T3
3510
3510
85,0
87,0
0,82
0,87
6,901)
8,051)
8,4
8,6
2,1
1,9
2,1
1,9
3,1
3,3
11
11
16
18
0,00450
0,00550
32
38
K11R
K11R
K12R
132 S2
132 SX2
132 SX2
5,3
6,3
6,6
T1-T3
T1-T3
T1-T3
3515
3514
3525
88,0
89,0
90,5
0,88
0,88
0,93
8,3
9,7
9,5
7,5
8,2
7,8
1,5
1,6
2,2
1,2
1,2
1,5
2,8
2,9
2,8
11
8
14
26
19
30
0,0110
0,0110
0,0258
57
57
88
K11R
K11R
K11R
160 M2
160 MX2
160 L2
8,6
12,0
14,0
T1-T3
T1-T3
T1-T3
3545
3520
3550
87,7
89,5
90,3
0,91
0,90
0,91
13,0
18,0
20,5
7,5
6,8
8,1
2,0
1,8
1,9
1,7
1,5
1,5
2,8
2,5
3,0
20
10
10
40
24
24
0,0575
0,0575
0,0675
120
120
138
K11R
180 M2
17,0
T1-T3
3550
91,0
0,93
24,0
7,5
1,9
1,6
2,8
13
30
0,1050
175
K11R
K11R
200 L2
200 LX2
23
27
T1-T3
T1-T3
3540
3555
91,5
93,0
0,93
0,91
32,5
38,0
7,2
7,7
1,9
1,7
1,6
1,3
2,6
2,7
8
10
23
23
0,1280
0,1930
210
255
K11R
225 M2
33
T1-T3
3570
93,0
0,91
47,0
7,8
1,6
1,2
2,7
13
30
0,375
360
K11R
250 M2
44
T1-T3
3570
92,5
0,93
62
7,1
1,8
1,4
2,4
13
35
0,65
490
K11R
K11R
280 S2
280 M2
56
70
T1-T3
T1-T3
3575
3570
93,5
94,0
0,89
0,89
81
100
7,2
7,2
1,5
1,3
1,3
1,2
1,8
2,2
22
21
45
35
1,21
1,44
730
815
K11R
K11R
K11R
315 S2
315 M2
315 MY2
82
96
132
T1-T3
T1-T3
T1-T3
3576
3575
3570
94,5
95,0
94,0
0,90
0,89
0,93
116
142
182
8,2
7,6
7,5
1,9
1,8
1,5
1,8
1,6
1,3
2,6
2,3
3,0
15
21
8
22
1,44
1,76
2,82
850
970
1150
1)
currents at 400 V
Other voltages and frequencies on inquiry.
Modifications of motors not yet certified by the PTB are possible!
16
Motor selection data
Design point 480 V, 60 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 60 cps
Type
P
kW
Temperature
class
n
η
cos ϕ
IA/IN
-
I
480 V
A
rpm
%
MA/MN MS/MN MK/MN
tE-time
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 1800 rpm - 4-pole design
KPER
KPER
63 K42)
63 G4
0,12
0,18
T1-T3
T1-T3
1670
1660
57,0
60,0
0,68
0,69
0,461)
0,631)
3,2
3,5
1,8
1,9
1,8
1,9
2,2
2,2
50
30
70
35
0,00019
0,00024
4,8
5,2
KPER
KPER
71 K4
71 G4
0,25
0,37
T1-T3
T1-T3
1680
1670
65,0
67,0
0,73
0,75
0,791)
1,081)
3,7
3,9
1,4
1,6
1,4
1,6
1,8
2,0
24
18
27
21
0,00040
0,00050
6,8
7,8
KPER
KPER
80 K4
80 G4
0,55
0,75
T1-T3
T1-T3
1680
1690
69,0
72,0
0,76
0,74
1,591)
2,051)
4,3
4,8
1,8
2,0
1,8
2,0
2,0
2,3
13
14
16
17
0,00087
0,00107
10,6
11,7
KPER
KPER
90 S4
90 L4
1,00
1,35
T1-T3
T1-T3
1710
1710
77,0
79,0
0,80
0,81
2,421)
3,101)
5,5
6,0
2,4
2,3
2,3
1,8
2,5
2,5
17
12
19
14
0,00207
0,00260
15,5
18
KPER
KPER
100 L4
100 LX4
2,0
2,5
T1-T3
T1-T3
1720
1740
80,0
83,0
0,80
0,78
4,651)
5,601)
6,6
7,3
2,8
2,3
2,6
2,2
2,9
2,9
11
11
13
12
0,00400
0,00725
23,5
30
KPER
112 M4
3,6
T1-T3
1740
85,0
0,77
8,11)
7,7
2,8
2,1
2,9
7
9
0,0090
37
K11R
K11R
132 S4
132 M4
5,8
7,8
T1-T3
T1-T3
1740
1760
86,0
88,5
0,82
0,80
10,0
13,2
6,9
6,5
2,0
2,2
1,7
1,9
2,9
2,8
9
9
15
27
0,0150
0,0280
53
72
K11R
K11R
160 M4
160 L4
12,0
15,5
T1-T3
T1-T3
1765
1775
91,0
91,0
0,88
0,85
18,1
24,0
6,5
7,9
2,0
2,6
1,7
2,1
2,5
3,2
14
7
30
23
0,0780
0,0900
123
136
K11R
K11R
180 M4
180 L4
17,0
20
T1-T3
T1-T3
1775
1775
90,5
91,0
0,87
0,84
26,0
32,0
7,3
7,6
2,0
2,2
1,7
1,9
2,7
2,9
12
7
35
23
0,1380
0,1380
180
185
K11R
200 L4
28
T1-T3
1775
93,0
0,88
41,5
7,2
1,9
1,6
2,5
7
30
0,2750
270
K11R
K11R
225 S4
225 M4
36
43
T1-T3
T1-T3
1775
1780
93,4
93,9
0,85
0,85
55
65
6,2
7,5
1,7
2,2
1,4
1,7
1,9
2,3
12
7
30
18
0,525
0,525
380
385
K11R
250 M4
52
T1-T3
1785
94,0
0,85
78
7,4
1,9
1,6
2,2
9
26
0,95
530
K11R
K11R
K11R
280 S4
280 S4
280 M4
58
70
84
T1-T3
T1-T3
T1-T3
1785
1785
1785
94,0
94,0
94,0
0,84
0,84
0,83
88
107
129
7,8
7,2
7,5
1,7
1,8
1,7
1,6
1,6
1,6
2,1
2,2
2,3
13
9
8
40
30
29
1,96
1,96
2,27
765
765
840
K11R
K11R
K11R
K11R
315
315
315
315
100
100
120
132
T1-T3
T1-T3
T1-T3
T1-T3
1785
1782
1780
1790
95,0
94,0
95,0
95,0
0,84
0,84
0,84
0,85
152
150
190
197
7,3
7,4
7,3
7,5
2,1
1,8
1,7
1,5
1,9
1,7
1,6
1,4
2,3
2,2
2,1
2,5
6
10
21
30
12
30
2,27
2,73
2,73
4,82
875
1000
1000
1200
S4
M4
M4
MY4
1)
2)
currents at 400 V
only available up to 415 V
Other voltages and frequencies on inquiry.
Modifications of motors not yet certified by the PTB are possible!
17
Motor selection data
Design point 480 V, 60 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 60 cps
Type
P
kW
Temperaturklasse
n
η
cos ϕ
IA/IN
-
I
480 V
A
min-1
%
MA/MN MS/MN MK/MN
tE-Zeit
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 1200 rpm - 6-pole design
KPER
KPER
80 K6
80 G6
0,37
0,55
T1-T3
T1-T3
1120
1110
62,0
66,0
0,70
0,69
1,301)
1,751)
3,5
4,0
2,0
2,1
1,8
2,1
2,0
2,2
26
22
28
26
0,00130
0,00175
11
12,5
KPER
KPER
90 S6
90 L6
0,65
0,95
T1-T3
T1-T3
1125
1125
69,0
71,0
0,71
0,71
1,941)
2,701)
3,7
4,3
1,8
2,1
1,7
2,0
1,9
2,2
30
23
35
27
0,00325
0,00425
16
19
KPER
100 L6
1,4
T1-T3
1140
75,0
0,73
3,751)
4,6
2,1
2,0
2,3
20
24
0,00625
24
KPER
112 M6
1,9
T1-T3
1150
79,0
0,74
4,701)
5,8
2,2
2,0
2,4
18
21
0,01225
33,5
K11R
K11R
K11R
132 S6
132 M6
132 MX6
3,0
4,0
5,5
T1-T3
T1-T3
T1-T3
1155
1160
1166
82,0
84,5
85,5
0,79
0,80
0,82
5,7
7,1
9,5
5,8
6,9
5,8
2,0
2,2
1,9
1,9
2,1
1,7
3,0
3,3
2,6
18
20
26
21
23
29
0,0180
0,0230
0,0430
49
53
70
K11R
K11R
160 M6
160 L6
7,6
11,0
T1-T3
T1-T3
1165
1170
86,5
86,0
0,82
0,82
12,9
18,7
5,8
6,3
2,0
2,3
1,7
2,1
2,6
2,9
24
11
30
29
0,0530
0,1130
89
123
K11R
180 L6
15,0
T1-T3
1178
89,5
0,87
23,0
7,1
2,3
2,1
3,0
20
45
0,2280
190
K11R
K11R
200 L6
200 LX6
19,0
23
T1-T3
T1-T3
1175
1178
88,0
90,5
0,80
0,90
32,5
34,0
7,0
6,8
2,6
2,2
2,1
1,7
3,3
2,5
14
40
0,2280
0,4430
190
265
K11R
225 M6
32
T1-T3
1177
92,0
0,88
47,5
6,1
2,2
1,8
2,3
10
30
0,8250
360
K11R
250 M6
40
T1-T3
1181
93,0
0,88
59
6,5
2,1
1,5
2,2
12
26
1,2800
475
K11R
K11R
280 S6
280 M6
48
55
T1-T3
T1-T3
1190
1190
94,0
94,0
0,87
0,87
71
81
7,5
8,1
2,1
2,2
1,7
2,0
2,5
2,9
2,630
3,330
715
810
K11R
K11R
K11R
315 S6
315 M6
315 MY6
76
85
100
T1-T3
T1-T3
T1-T3
1190
1190
1185
94,5
94,5
94,5
0,87
0,87
0,86
111
124
148
8,7
8,1
8,2
2,3
2,0
1,9
2,1
1,8
1,7
3,0
2,5
2,3
3,330
3,600
6,000
840
890
1080
1)
currents at 400 V
Other voltages and frequencies on inquiry.
Modifications of motors not yet certified by the PTB are possible!
18
Motor selection data
Design point 480 V, 60 cps, EEx e
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 60 cps
Type
P
kW
Temperaturklasse
n
η
cos ϕ
IA/IN
-
I
480 V
A
min-1
%
MA/MN MS/MN MK/MN
tE-Zeit
T3 T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 900 rpm - 8-pole design
KPER
KPER
80 K8
80 G8
0,18
0,25
T1-T3
T1-T3
820
820
52,0
55,0
0,64
0,67
0,781)
1,001)
2,7
3,1
1,6
2,3
1,6
2,3
1,9
2,4
150
60
180
70
0,00130
0,00175
10,5
12
KPER
KPER
90 S8
90 L8
0,37
0,55
T1-T3
T1-T3
850
845
59,0
64,0
0,56
0,58
1,611)
2,141)
3,2
3,3
1,5
1,6
1,5
1,6
2,0
2,1
55
55
60
60
0,00300
0,00375
15
18
KPER
KPER
100 L8
100 LX8
0,65
0,95
T1-T3
T1-T3
850
855
66,0
74,0
0,63
0,68
2,241)
2,751)
3,3
4,5
1,5
2,0
1,5
2,0
1,8
2,5
60
60
70
70
0,00625
0,00900
23
28
KPER
112 M8
1,3
T1-T3
850
75,0
0,67
3,901)
4,5
1,7
1,7
1,9
50
60
0,01225
33,5
K11R
K11R
132 S8
132 M8
2,2
3,0
T1-T3
T1-T3
850
850
75,0
80,8
0,77
0,76
4,6
6,0
3,8
4,9
1,7
1,8
1,4
1,7
1,9
2,3
30
28
35
30
0,0180
0,0230
49
57
K11R
K11R
K11R
160 M8
160 MX8
160 L8
4,0
5,5
7,6
T1-T3
T1-T3
T1-T3
875
870
880
82,0
83,5
84,5
0,70
0,71
0,71
8,4
11,2
15,3
4,6
4,9
5,4
2,0
2,0
2,3
1,9
1,9
2,0
2,5
2,5
2,8
35
35
25
45
45
35
0,0430
0,0530
0,1130
80
90
122
K11R
180 L8
11,0
T1-T3
875
85,5
0,71
22,0
5,5
2,5
2,1
2,9
10
35
0,1450
140
K11R
200 L8
15,0
T1-T3
880
87,5
0,70
29,5
5,7
2,4
2,2
3,1
0,2280
195
K11R
K11R
225 S8
225 M8
19,5
24
T1-T3
T1-T3
885
885
89,0
91,0
0,80
0,80
33,0
39,7
6,2
5,4
2,3
2,1
2,0
1,8
2,9
2,2
0,4400
0,8250
275
360
K11R
250 M8
32
T1-T3
885
90,5
0,81
52,5
5,3
2,1
1,6
2,1
1,3500
472
K11R
K11R
280 S8
280 M8
40
48
T1-T3
T1-T3
895
892
93,5
94,0
0,78
0,79
66
78
6,3
6,5
1,9
2,1
1,7
1,8
2,3
2,4
2,630
3,330
700
805
K11R
K11R
K11R
315 S8
315 M8
315 MY8
60
82
95
T1-T3
T1-T3
T1-T3
890
890
890
94,0
94,0
94,0
0,81
0,78
0,77
95
135
158
6,0
7,0
7,7
1,7
2,1
2,0
1,6
1,8
1,8
2,1
2,5
2,4
3,330
3,600
6,000
850
880
1080
1)
currents at 400 V
Other voltages and frequencies on inquiry.
Modifications of motors not yet certified by the PTB are possible!
19
Motor selection data
Design voltage range
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage range, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
cos ϕ
rpm
-
I
IA/IN
380…420 V
A
MA/MN MS/MN MK/MN
tE-time
T3,T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 3000 rpm - 2-pole design
KPER
KPER
63 K2
63 GX2
0,18
0,25
T1-T3
T1-T3
2710...2810
2700...2760
0,85...0,75
0,88...0,83
0,53
0,6
3,7
4,2
1,6
2,2
1,6
2,1
2,0
2,2
29
25
30
29
0,00013
0,00015
4,9
5,2
KPER
KPER
71 K2
71 G2
0,37
0,55
T1-T3
T1-T3
2700...2780
2740...2810
0,89...0,79
0,84...0,74
0,97
1,43
4,1
4,8
1,7
2,2
1,7
2,2
2,2
2,5
16
11
18
13
0,00025
0,00032
6,7
7,6
KPER
KPER
80 K2
80 G2
0,75
1,10
T1-T3
T1-T3
2780...2830
2800...2850
0,88...0,79
0,86...0,76
1,76
2,6
5,3
5,6
1,9
2,3
1,9
2,3
2,4
2,5
14
8
16
10
0,00057
0,00072
10,7
11,5
KPER
KPER
90 S2
90L2
1,30
1,85
T1-T3
T1-T3
2830...2860
2850...2880
0,90...0,85
0,89...0,83
2,75
3,85
6,5
7,4
2,2
3,0
2,2
3,0
2,6
3,2
14
9
16
12
0,00132
0,00170
16
19
KPER
100 L2
2,50
T1-T3
2850...2880
0,89...0,85
5,2
6,8
2,5
2,4
2,7
13
16
0,00275
25
KPER
KPER
112 M2
112 MX2
3,30
4,10
T1-T3
T1-T3
2905...2925
2900...2920
0,85...0,77
0,89...0,84
6,9
8,1
7,7
7,9
2,3
2,5
2,1
1,9
3,1
3,3
11
11
16
18
0,00450
0,00550
32
38
K11R
K12R
132 S2
132 SX2
4,6
5,5
T1-T3
T1-T3
2900
2930
0,88
0,92
9,2
10,1
6,6
7,0
1,4
2,1
1,2
1,3
2,8
2,6
11
16
28
35
0,0110
0,0258
57
88
K11R
K11R
K11R
160 M2
160 MX2
160 L2
7,5
10,0
12,5
T1-T3
T1-T3
T1-T3
2945
2935
2945
0,90
0,90
0,91
14,4
19,1
23
6,6
6,1
7,0
1,9
1,8
1,8
1,6
1,5
1,4
2,7
2,5
2,8
19
11
10
40
28
27
0,0575
0,0575
0,0675
120
120
138
K11R
K11R
K11R
180 M2
200 L2
200 LX2
15,0
20
24
T1-T3
T1-T3
T1-T3
2945
2935
2950
0,92
0,92
0,90
27
36
43,0
6,6
6,2
6,6
1,8
1,8
1,6
1,5
1,4
1,2
2,6
2,4
2,5
13
8
9
30
25
24
0,105
0,128
0,193
175
210
255
K11R
225 M2
28
T1-T3
2970
0,91
50
7,1
1,5
1,0
2,6
14
30
0,375
360
K11R
250 M2
36
T1-T3
2970
0,93
63
6,8
1,9
1,5
2,6
18
40
0,65
490
K11R
K11R
280 S2
280 M2
47
58
T1-T3
T1-T3
2975
0,88
107
6,7
1,4
1,3
2,1
21
35
1,21
1,44
730
815
K11R
K11R
K11R
315 S2
315 M2
315 MY2
68
80
110
T1-T3
T1-T3
T1-T3
1,44
1,76
2,82
850
970
1170
Other voltages and frequencies on inquiry.
Modifications of motors not yet certified by the PTB are possible!
20
Motor selection data
Design voltage range
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage range, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
cos ϕ
rpm
-
I
IA/IN
380…420 V
A
MA/MN MS/MN MK/MN
tE-time
T3,T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 1500 rpm - 4-pole design
KPER
KPER
63 K4
63 G4
0,12
0,18
T1-T3
T1-T3
not possible in voltage range
possible with 0,12 kW
0,00019
0,00024
4,8
5,2
KPER
KPER
71 K4
71 G4
0,25
0,37
T1-T3
T1-T3
1350...1390
1350...1390
0,79...0,69
0,79...0,70
0,79
1,08
3,4
3,6
1,4
1,6
1,4
1,6
1,8
2,0
24
18
27
21
0,00040
0,00050
6,8
7,8
KPER
KPER
80 K4
80 GX4
0,55
0,75
T1-T3
T1-T3
1365...1395
1320...1360
0,80...0,71
0,84...0,77
1,59
2,00
3,9
3,8
1,8
1,9
1,8
1,8
2,0
1,9
13
16
16
20
0,00087
0,00107
10,6
11,7
KPER
KPER
90 S4
90 L4
1,00
1,35
T1-T3
T1-T3
1395...1415
1395...1420
0,84...0,77
0,84...0,78
2,40
3,10
5,1
5,5
2,4
2,3
2,3
1,8
2,5
2,5
17
12
19
14
0,00207
0,00260
15,5
18
KPER
KPER
100 L4
100 LX4
2,00
2,5
T1-T3
T1-T3
1410...1430
1435...1450
0,82...0,74
0,81...0,74
4,65
5,6
6,0
6,7
2,8
2,3
2,6
2,2
2,9
2,9
11
11
13
12
0,00400
0,00725
23,5
30
KPER
112 M4
3,6
T1-T3
1430...1450
0,82...0,73
8,1
7,0
2,8
2,1
2,9
7
9
0,009
37
K11R
K11R
132 S4
132 M4
5,0
6,8
T1-T3
T1-T3
1435
1455
0,83
0,85...0,78
10,5
14,0
6,3
5,9
2,0
2,1
1,6
1,8
2,8
2,7
8
10
16
27
0,015
0,028
53
72
K11R
K11R
160 M4
160 L4
10,0
13,5
T1-T3
T1-T3
1465
1470
0,89
0,87...0,83
18,9
26,0
6,1
7,4
2,0
2,5
1,7
2,0
2,5
3,0
16
7
35
25
0,078
0,090
123
136
K11R
K11R
180 M4
180 L4
15,0
17,5
T1-T3
T1-T3
1475
1475
0,87
0,86...0,82
28,5
34,0
6,4
6,9
1,9
2,1
1,6
1,8
2,5
2,8
13
8
40
27
0,138
0,138
180
185
K11R
200 L4
24,0
T1-T3
1477
0,87
45,0
6,4
1,8
1,5
2,4
8
30
0,275
270
K11R
K11R
225 S4
225 M4
30
36
T1-T3
T1-T3
1475
1480
0,85
0,85
59,0
69,0
5,7
7,0
1,6
2,2
1,4
1,7
1,9
2,3
12
7
30
20
0,525
0,525
380
385
K11R
250 M4
44
T1-T3
1485
0,86
83
6,9
1,8
1,6
2,1
9
29
0,95
530
K11R
K11R
280 S4
280 M4
58
70
T1-T3
T1-T3
1485
0,84
135
7,1
2,0
1,8
2,4
11
30
1,96
2,27
765
840
K11R
K11R
K11R
315 S4
315 M4
315 MY4
84
100
110
T1-T3
T1-T3
T1-T3
2,27
2,73
4,82
875
1000
1200
Other voltages and frequencies on inquiry.
T1,T2-design on inquiry.
Modifications of motors not yet certified by the PTB are possible!
21
Motor selection data
Design voltage range
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage range, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
cos ϕ
rpm
-
I
IA/IN
380…420 V
A
MA/MN MS/MN MK/MN
tE-time
T3,T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 1000 rpm - 6-pole design
KPER
KPER
80 K6
80 G6
0,37
0,55
T1-T3
T1-T3
905...930
0,74...0,65
1,3
not possible in voltage range
3,2
2,0
1,8
2,0
26
28
0,00130
0,00175
11
12,5
KPER
KPER
90 S6
90 L6
0,65
0,95
T1-T3
T1-T3
915...935
0,74...0,67 1,95
not possible in voltage range
3,4
1,8
1,7
1,9
30
35
0,00325
0,00425
16
19
KPER
100 L6
1,4
T1-T3
930...950
0,76...0,69
3,75
4,2
2,1
2,0
2,3
20
24
0,00625
24
KPER
112 M6
1,9
T1-T3
945...955
0,78...0,71
4,7
5,3
2,2
2,0
2,4
18
21
0,01225
33,5
K11R
K11R
K11R
132 S6
132 M6
132 MX6
2,6
3,5
4,8
T1-T3
T1-T3
T1-T3
950
960
963
0,83...0,77
0,85...0,79
0,83
6,1
7,5
10,3
5,1
6,2
5,0
1,8
2,0
1,8
1,8
2,0
1,6
2,8
3,0
2,5
18
23
26
21
20
30
0,018
0,023
0,043
49
53
70
K11R
K11R
160 M6
160 L6
6,6
9,7
T1-T3
T1-T3
965
970
0,86...0,82
0,87...0,80
13,8
20,0
5,2
5,6
1,9
2,2
1,6
1,9
2,5
2,2
26
12
30
29
0,053
0,113
89
123
K11R
180 L6
13,2
T1-T3
975
0,87
25,5
6,2
2,2
2,0
2,9
21
45
0,228
190
K11R
K11R
200 L6
200 LX6
16,5
20
T1-T3
T1-T3
977
0,90...0,89
37,5
6,0
2,2
1,6
2,5
14
45
0,228
0,443
190
265
K11R
225 M6
27
T1-T3
975
0,88..0,84
51,0
5,4
2,1
1,8
2,3
10
35
0,825
360
K11R
250 M6
33
T1-T3
1,28
475
K11R
K11R
280 S6
280 M6
40
46
T1-T3
T1-T3
2,63
3,33
715
810
K11R
K11R
K11R
315 S6
315 M6
315 MY6
64
76
85
T1-T3
T1-T3
T1-T3
3,33
3,60
6,00
840
890
1080
988
0,90...0,88
Other voltages and frequencies on inquiry.
T1,T2-design on inquiry.
Modifications of motors not yet certified by the PTB are possible!
22
116
7,0
2,2
1,8
2,5
8
28
Motor selection data
Design voltage range
Three-phase motors with squirrel-cage rotor
Increased-safety type of protection EEx e II according to DIN EN 50014/50019
for design voltage range, temperature classes T1, T2 and T3
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
kW
Temperature
class
n
cos ϕ
rpm
-
I
IA/IN
380…420 V
A
MA/MN MS/MN MK/MN
tE-time
T3,T1,T2
s
s
J
m
kgm2
kg
Synchronous speed 750 rpm - 8-pole design
KPER
KPER
80 K8
80 G8
0,18
0,25
T1-T3
T1-T3
not possible in voltage range
655...680
0,70...0,62
1,0
KPER
KPER
90 S8
90L8
0,37
0,55
T1-T3
T1-T3
not possible in voltage range
not possible in voltage range
KPER
KPER
100 L8
100 LX8
0,65
0,95
T1-T3
T1-T3
690...705
700...710
0,67...0,60
0,72...0,64
KPER
112 M8
1,3
T1-T3
690...710
K11R
K11R
132 S8
132 M8
1,9
2,6
T1-T3
T1-T3
K11R
K11R
K11R
160 M8
160 MX8
160 L8
3,5
4,8
6,6
K11R
K11R
180 L8
200 L8
K11R
K11R
2,8
2,3
2,2
2,4
60
70
0,00060
8,1
2,3
2,75
2,9
4,1
1,5
2,0
1,5
2,0
1,8
2,5
60
60
70
70
0,00625
0,00900
23
28
0,70...0,61
3,9
4,1
1,8
1,7
1,9
50
60
0,01225
33,5
700
705
0,75
0,78...0,71
5,0
6,6
3,8
4,4
1,6
1,8
1,6
1,7
2,2
2,6
30
27
35
30
0,018
0,023
49
57
T1-T3
T1-T3
T1-T3
720
720
730
0,76...0,70
0,76...0,70
0,76...0,68
8,8
11,8
16,3
4,2
4,4
4,7
1,8
2,0
1,9
1,7
1,9
1,8
2,4
2,5
2,4
40
40
29
45
45
35
0,043
0,053
0,113
80
90
122
9,7
13,2
T1-T3
T1-T3
725
0,77...0,69
22,5
5,0
2,3
2,0
2,6
10
40
0,145
0,228
140
195
225 S8
225 M8
16,5
20
T1-T3
T1-T3
0,440
0,825
275
360
K11R
250 M8
27
T1-T3
1,35
472
K11R
K11R
280 S8
280 M8
33
40
T1-T3
T1-T3
2,63
3,33
700
805
K11R
K11R
K11R
315 S8
315 M8
315 MY8
50
68
80
T1-T3
T1-T3
T1-T3
3,33
3,60
6,00
850
880
1080
Other voltages and frequencies on inquiry.
T1,T2-design on inquiry.
Modifications of motors not yet certified by the PTB are possible!
23
Constructive selection data
Dimensions
Three-phase motors with squirrel-cage rotor, type ranges KPER, K11R...EEx e II
Size
a
B
a1
P
b
A
b1
N
c
HA
c1
LA
d
D
d1
DA
e
BB
e1
M
f
AB
f1
T
g
AC
g1
-
h
H
k
L
k1
LC
l
E
l1
EA
m
BA
n
AA
o
-
p
HD
q
-
r
-
s
K
s1
S
t
GA
t1
GC
u
F
u1
FA
w1
C
w2
CA
A
-
Bl
-
x
-
z
-
Relubricating
facility
possible
Type
Hole pattern
Increased safety type of protection EEx e II acc. to DIN EN 50019; with surface cooling, type of cooling IC 411
degree of protection IP 54, IP 55
-
-
KPER 63
KPER 63
K2,4,6
G2,4,6
80
80
140
140
100
100
95
95
10
10
9
9
11
11
11
11
100
100
115
115
128
128
3
3
109
109
63
63
179
179
205
205
23
23
23
23
28
28
183
183
M20
M20
8
8
9
9
12,5
12,5
12,5
12,5
4
4
4
4
40
40
39
39
58
58
14
14
111
111
106
106
4L
4L
no
no
KPER 71
KPER 71
K2,4,6,8
G2,4,6,8
90
90
160
160
112
112
110
110
11
11
9
9
14
14
14
14
116
116
130
130
138
138
3,5
3,5
124
124
71
71
206
206
239
239
30
30
30
30
32
32
197
197
M20
M20
8
8
9
9
16
16
16
16
5
5
5
5
45
45
43,5
43,5
61
61
14
14
111
111
106
106
4L
4L
no
no
KPER 80
KPER 80
K2,4,6,8
G2,4,6,8
100
100
200
200
125
125
130
130
12
12
10
10
19
19
19
19
125
125
165
165
168
168
3,5
3,5
139
139
80
80
249
249
293
293
40
40
40
40
38
38
213
213
M20
M20
10
10
11
11
21,5
21,5
21,5
21,5
6
6
6
6
50
50
63
63
67
67
16
16
111
111
106
106
4L
4L
no
no
KPER 90
KPER 90
S2,4,6,8
L2,4,6,8
100
125
200
200
140
140
130
130
14
14
10
10
24
24
22
22
130
155
165
165
178
178
3,5
3,5
157
157
90
90
276
298
330
352
50
50
50
50
40
40
232
232
M25
M25
10
10
11
11
27
27
24,5
24,5
8
8
6
6
56
56
74
71
70
70
16
16
111
111
106
106
4L
4L
no
no
KPER 100
KPER 100
L2,4,6,8
LX4,8
140
140
250
250
160
160
180
180
15
11
11
11
28
28
24
28
175
171
215
215
192
188
4
4
177
196
100
100
332
359
386
425
60
60
50
60
45
33
249
259
236
M25
M25
12
12
14
14
31
31
27
31
8
8
8
8
63
63
73
102
75
77
18
20
111
111
106
106
4L
4L
no
no
KPER 112
KPER 112
M2,6,8
M4
140
140
250
250
190
190
180
180
18
18
11
11
28
28
28
28
180
180
215
215
224
224
4
4
196
196
112
112
359
393
425
459
60
60
60
60
50
50
271
271
236
236
M25
M25
12
12
14
14
31
31
31
31
8
8
8
8
70
70
95
129
77
77
20
20
111
111
106
106
4L
4L
no
no
K11R
K12R
K11R
K11R
K11R
K11R
132
132
132
132
132
132
S2, SX2
SX2
S4,6,8
M4
MX6
M6,8
140
140
140
178
178
178
300
300
300
300
300
300
216
216
216
216
216
216
230
230
230
230
230
230
16
16
16
16
16
18
12
12
12
12
12
12
38
38
38
38
38
38
32
32
32
38
38
32
180
180
180
218
218
218
265
265
265
265
265
265
256
256
256
256
256
256
4
4
4
4
4
4
217
258
217
258
258
217
178
200
178
200
200
178
132
132
132
132
132
132
459
481
459
481
481
479
542
565
542
565
565
562
80
80
80
80
80
80
80
80
80
80
80
80
55
47
55
55
55
55
50
50
50
50
50
50
168
173
168
173
173
188
339
361
339
361
361
339
291
308
291
308
308
291
M32
M32
M32
M32
M32
M32
12
12
12
12
12
12
14
14
14
14
14
14
41
41
41
41
41
41
35
35
35
41
41
35
10
10
10
10
10
10
10
10
10
10
10
10
89
89
89
89
89
89
153
176
153
138
138
135
108
114
108
114
114
108
35
35
35
35
35
35
155
155
155
155
155
155
145
145
145
145
145
145
4L
4L
4L
4L
4L
4L
no
no
no
yes
yes
no
K11R
K11R
K11R
K11R
K11R
K11R
160
160
160
160
160
160
M6,8
MX8
M2
M4
MX2
L2,4,6,8
210
210
210
210
210
254
350
350
350
350
350
350
254
254
254
254
254
254
250
250
250
250
250
250
18
18
18
18
18
18
13
13
13
13
13
13
42
42
42
42
42
42
38
38
38
42
42
42
257
257
257
257
257
301
300
300
300
300
300
300
296
296
296
296
296
296
5
5
5
5
5
5
258
258
313
313
313
313
200
200
242
242
242
242
160
160
160
160
160
160
559
559
571
571
571
609
643
643
686
686
686
724
110
110
110
110
110
110
80
80
80
110
110
110
60
60
60
60
60
60
55
55
55
55
55
55
221
221
211
211
211
249
386
386
435
435
435
435
338
338
360
360
360
360
M32
M32
M40
M40
M40
M40
15
15
15
15
15
15
18
18
18
18
18
18
45
45
45
45
45
45
41
41
41
45
45
45
12
12
12
12
12
12
10
10
10
12
12
12
108
108
108
108
108
108
135
135
148
148
148
142
114
114
138
138
138
138
35
35
35
35
35
35
155
155
192
192
192
192
145
145
165
165
165
165
4L
4L
4L
4L
4L
4L
no
no
no
no
yes
yes
K11R
K11R
K11R
K11R
K11R
180
180
180
180
180
M2
M4
L4
L6
L8
241
241
279
279
279
350
350
350
350
350
279
279
279
279
279
250
250
250
250
250
20
20
20
20
20
13
13
13
13
13
48
48
48
48
48
48
42
48
42
42
288
288
326
326
326
300
300
300
300
300
328
328
328
328
328
5
5
5
5
5
351
351
351
351
313
261
261
261
261
242
180
180
180
180
180
635
635
680
680
609
751
751
796
796
724
110
110
110
110
110
110
110
110
110
110
65
65
65
65
65
62
62
62
62
62
239
239
284
284
249
460
460
460
460
440
396
396
396
396
360
M40
M40
M40
M40
M40
15
15
15
15
15
18
18
18
18
18
51,5
51,5
51,5
51,5
51,5
51,5
51,5
51,5
45
45
14
14
14
14
14
14
14
14
12
12
121
121
121
121
121
169
169
176
176
104
147
138
147
147
138
35
35
35
35
35
192
192
192
192
192
165
165
165
165
165
4L
4L
4L
4L
4L
yes
yes
yes
yes
yes
K11R
K11R
K11R
K11R
200
200
200
200
L2,6,8
L4
LX2
LX6
305
305
305
305
400
400
400
400
318
318
318
318
300
300
300
300
22
22
22
22
15
15
15
15
55
55
55
55
48
48
55
48
360
360
360
360
350
350
350
350
372
372
372
372
5
5
5
5
351
390
390
390
261
300
300
300
200
200
200
200
680
727
727
727
796
851
851
851
110
110
110
110
110
110
110
110
70
70
70
70
70
70
70
70
284
292
292
292
480
538
538
538
396
435
435
435
M50
M50
M50
M50
19
19
19
19
18
18
18
18
59
59
59
59
51,5
59
59
51,5
16
16
16
16
14
16
16
14
133
133
133
133
138
193
193
193
147
168
168
168
35
40
40
40
192
192
192
192
165
165
165
165
4L
4L
4L
4L
yes
yes
yes
yes
K11R
K11R
K11R
K11R
225
225
225
225
S8
M2
S4
M4,6,8
286
311
286
311
450
450
450
450
356
356
356
356
350
350
350
350
25
25
25
25
16
16
16
16
60
55
55
60
55
55
55
55
343
368
343
368
400
400
400
400
413
413
413
413
5
5
5
5
390
440
440
440
300
326
326
326
225
225
225
225
757
862
862
862
881
947
947
977
140
110
110
140
110
110
110
110
75
75
75
75
75
75
75
75
292
382
382
382
525
551
551
551
465
450
480
480
M50
M50
M50
M50
19
19
19
19
18
18
18
18
64
64
64
64
59
59
59
59
18
16
16
16
16
16
16
16
149
149
149
149
196
267
292
267
168
177
177
177
40
45
45
45
212
212
212
212
207
207
207
207
8L
8L
8L
8L
yes
yes
yes
yes
K11R
K11R
250
250
M2
M4,6,8
349
349
550
550
406
406
450
450
28
28
18
18
60
65
55
55
412
412
500
500
469
469
5
5
490
490
388
388
250
250
924 1042 140
924 1042 140
110
110
84
84
84
84
383
383
688
688
541
541
M63
M63
24
24
18
18
64
69
59
59
18
18
16
16
168
168
305
305
206
206
50
50
280
280
242
242
8L
8L
yes
yes
K11R
K11R
K11R
K11R
280
280
280
280
S2
S4,6,8
M2
M4,6,8
368
368
419
419
550
550
550
550
457
457
457
457
450
450
450
450
40
40
40
40
18
18
18
18
65
75
65
75
65
65
65
65
431
431
482
482
500
500
500
500
522
522
522
522
5
5
5
5
550
550
550
550
420
420
420
420
280
280
280
280
1065
1065
1120
1120
1218
1218
1273
1273
140
140
140
140
140
140
140
140
96
96
96
96
94
94
94
94
519
519
574
574
700
700
700
700
546
546
546
546
M63
M63
M63
M63
24
24
24
24
18
18
18
18
69
79,5
69
79,5
69
69
69
69
18
20
18
20
18
18
18
18
190
190
190
190
380
380
384
384
211
211
211
211
55
55
55
55
280
280
280
280
242
242
242
242
8L
8L
8L
8L
yes
yes
yes
yes
K11R
K11R
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
315
315
S2
S4,6,8
M2
M4
M6,8
MY2
MY4,6,8
406
406
457
457
457
457
457
660
660
660
660
660
660
660
508
508
508
508
508
508
508
550
550
550
550
550
550
550
44
44
44
44
44
44
44
22
22
22
22
22
22
22
65
80
65
80
80
65
80
65
70
65
70
70
65
70
554
554
554
554
554
573
573
600
600
600
600
600
600
600
590
590
590
590
590
590
590
6
6
6
6
6
6
6
550
550
550
550
550
660
660
420
420
420
420
420
487
487
315
315
315
315
315
315
315
1120
1150
1200
1230
1150
1295
1325
1273
1303
1353
1383
1303
1448
1478
140
170
140
170
170
140
170
140
140
140
140
140
140
140
120
120
120
120
120
120
120
132
132
132
132
132
110
110
574
574
654
654
574
655
655
750
750
750
750
750
750
830
546
576
546
576
576
636
666
M63
M63
M63
M63
M63
M63
M63
28
28
28
28
28
28
28
22
22
22
22
22
22
22
69
85
69
85
85
69
85
69
74,5
69
74
74,5
69
74,5
18
22
18
22
22
18
22
18
20
18
20
20
18
20
216
216
216
216
216
216
216
320
320
400
400
320
495
495
211
211
211
211
211
225
225
55
55
55
55
55
55
55
280
280
280
280
280
280
280
242
242
242
242
242
242
242
8L
8L
8L
8L
8L
8L
8L
yes
yes
yes
yes
yes
yes
yes
The dimensions of the series K21R and K11R are
identical
Tolerance for counter parts H7
2nd shaft end only for direct coupling
Bl = minimum distance for air inlet
= air inlet
→
24
Threaded center bores in the shaft end DIN 332-DS:
at diameter 11 up to 13 M4
at diameter 14 up to 16 M5
at diameter 17 up to 21 M6
at diameter 22 up to 24 M8
at diameter 25 up to 30 M10
at
at
at
at
at
diameter
diameter
diameter
diameter
diameter
31 up to 38
39 up to 50
51 up to 90
51 up to 90
100 M24
M12
M16
M20
M21
* Design with larger terminal box
** Design with VIK terminal box with entry bush
I Terminal box for threaded joint
2) Conduit according to cable diameter max. 83 mm
3) Thread lead … x 1,5
Special equipment relubricating facility
Flat grease nipple with head diameter 10 mm,
Grease outlet opposite to flat grease nipple
Special equipment relubricating facility not available for K11R 132 S, SX2, M6, M8 and
K21R 160 M, MX8
Three eye-bolts only in case of type of construction IM V1 from K11R 180 M2, L4
25
Constructive selection data
Bearing arrangement
Basic design
γ-type seal
RB85
RB85
RB100
RB85
RB100
80
90
100
110
110
110
-
130
130
130
140
140
150
150
170
170
-
6201 2Z C3
6202 2Z C3
6204 2Z C3
6205 2Z C3
6205 2Z C3
6206 2Z C3
6206 2Z C3
6207 2Z C3
6308 2Z C3
6308 2Z C3
6309 2Z C3
6309 2Z C3
6310 C3
6310 C3
6310 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
6314 C3
6316 C3
6316 C3
6316 C3
6316 C3
6316 C3
6316 C3
6317 C3 *)
6317 C3 *)
Wave washer
50A
60A
60A
60A
65A
65A
70A
70A
80A
80A
80A
80A
-
N-side
Antifriction bearing
V-type seal
LX
M
S, SX2,M6,8
M4,MX6
M6,8,MX8
M2,4,MX2, L
L8
M2
M4,L4,6
L2,6,8
LX2,6,L4
S8
M2
S4,M4,6,8
M2
M4,6,8 VL
S2,M2
S4,6,8,M4,6,8 VL
S2
M2 VL
S4,6,8 VL
M4,6,8 VL
MY2 VL
MY4,6,8 VL
6201 2Z C3
6202 2Z C3
6204 2Z C3
6205 2Z C3
6205 2Z C3
6206 2Z C3
6206 2Z C3
6208 2Z C3
6308 2Z C3
6309 2Z C3
6310 2Z C3
6310 2Z C3
6310 C3
6312 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
6314 C3
NU 316 E
6316 C3
NU 317 E
6316 C3
NU 317 E
NU 317 E
NU 2220 E
NU 317 E
NU 320 E
Disk spring
63
71
80
90
100
100
112
132
132
160
160
180
180
180
200
200
225
225
225
250
250
280
280
315
315
315
315
315
315
Wave washer
KPER
KPER
KPER
KPER
KPER
KPER
KPER
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
Antifriction bearing
V-type seal
D-side
Type
50A
50A
50A
60A
60A
65A
65A
70A
70A
80A
80A
80A
80A
80A
80A
85A
85A
32
35
47
52
52
62
62
-
fixed
bearing
without
without
without
without
without
without
without
without
without
without
without
without
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
*) In case of vertical types of construction Q317 C3; size 315 as standard with relubricating device
Special design „heavy bearing arrangement“
D-side
Antifriction bearing V-type
rotary seal
Type
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
26
132
132
160
160
180
180
180
200
200
225
225
225
250
280
315
S, SX2,M6,8
M4,MX6
M6,8,MX8
M2,4,MX2,L
L8
M2
M4,L4,6
L2,6,8
LX2,6,L4
S8
M2
S4,M4,6,8
M2
S2,M2
S2
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
208
308
309
310
310
310
312
312
312
313
313
314
314
316
316
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
40A
40A
45A
50A
50A
50A
60A
60A
60A
65A
65A
70A
70A
80A
80A
N-side
Antifriction bearing V-type
rotary seal
6207 2Z C3
6308 2Z C3
6308 2Z C3
6309 2Z C3
6309 2Z C3
6310 C3
6310 C3
6310 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
6316 C3
6316 C3
50A
50A
50A
60A
60A
60A
65A
70A
80A
80A
fixed
bearing
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
Constructive selection data
Terminal box
Basic design
Type
Terminal box
KPER 63 - 80
KPER 90 - 112
K11R 132
K11R
K11R
K11R
K11R
K11R
160
160
160
160
160
M6,8
MX8
M2,4
MX2
L
Terminal plate according to DIN 46 295
Thread
of the
terminal stud
AlSi10 Mg
GG25
KS 10 A
GG
GG
GG
GG
GG
KS
KS
KS
KS
KS
Cable diameter range
16 A
M20x1,5-Ms
M25x1,5-Ms
7 - 13 mm
9 - 17 mm
40 A
M32x1,5-Ms
11 - 21 mm
S 10x1
S 10x1
S 14x1,25
S 14x1,25
S 14x1,25
40
40
53
65
65
A
A
A
A
A
M32x1,5-Ms
M32x1,5-Ms
M40x1,5-Ms
M40x1,5-Ms
M40x1,5-Ms
11
11
19
19
19
GG 63
GG 63
KS 14 A
KS 14 A
S 14x1,25
S 14x1,25
65 A
65 A
M40x1,5-Ms
M40x1,5-Ms
19 - 28 mm
19 - 28 mm
GG 63/100
GG100
GG100
KS 14 A
KS 14 A
KS 14 A
S 14x1,25
S 14x1,25
S 14x1,25
65 A
65 A
65 A
M50x1,5-Ms
M50x1,5-Ms
M50x1,5-Ms
27 - 35 mm
27 - 35 mm
27 - 35 mm
K11R 225
K11R 250
GG100
GG200
KS 14 A
KS 18 A
S 14x1,25
S 18x1,5
65 A
110 A
M50x1,5-Ms
M63x1,5-Ms
27 - 35 mm
34 - 45 mm
K11R 280
GG200
KS 18 A
S 18x1,5
110 A
M63x1,5-Ms
34 - 45 mm
K11R 315
GG200
KS 18 A
S 18x1,5
110 A
M63x1,5-Ms
34 - 45 mm
K11R 200 L2,6,8
K11R 200 L4
K11R 200 LX2,6
10
10
14
14
14
Entry
A
A
A
A
A
K11R 180 M
K11R 180 L
25
25
63
63
63
S 10x1
max.
design
current
-
21
21
28
28
28
mm
mm
mm
mm
mm
27
Motor selection data
Design point 400 V, 50 cps, EEx d, de
Three-phase motors with squirrel-cage rotor
Flame-proof enclosure type of protection EEx d II acc. to DIN EN 50014/50018
temperature class T4
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
J
m
kgm2
kg
Synchronous speed 3000 rpm - 2-pole design
K8.R
K8.R
63 K 2
63 L 2
0,18
0,25
2710
2740
64,0
67,0
0,85
0,85
0,48
0,63
3,8
4,2
2,5
2,6
3,0
3,1
0,00011
0,00018
13
14
K8.R
K8.R
71 K 2
71 L 2
0,37
0,55
2800
2820
68,0
72,0
0,81
0,82
0,97
1,34
4,5
4,9
2,7
2,8
3,5
3,6
0,00028
0,00039
16
17
K8.R
K8.R
80 K 2
80 L 2
0,75
1,10
2790
2820
74,0
78,0
0,84
0,85
1,74
2,40
4,8
5,5
2,7
2,8
3,3
3,5
0,00058
0,00080
24
25
K8.R
K8.R
90 L 2
90 LX 2
1,50
2,20
2840
2850
79,0
82,0
0,86
0,86
3,20
4,50
5,5
5,6
2,7
2,7
3,2
3,3
0,00130
0,00180
31
35
K8.R
100 L 2
3,0
2850
83,0
0,87
6,00
6,8
2,7
3,3
0,00290
45
K8.R
112 M 2
4,0
2880
85,0
0,88
7,70
6,5
2,3
3,1
0,00051
53
K8.R
K8.R
132 S 2
132 SX 2
5,5
7,5
2880
2910
85,0
86,5
0,86
0,86
10,9
14,6
6,0
6,8
2,5
2,7
3,3
3,5
0,0089
0,0125
95
100
K8.R
K8.R
K8.R
160 M 2
160 MX 2
160 L 2
11,0
15,0
18,5
2925
2920
2925
88,5
89,5
91,0
0,89
0,92
0,92
20,0
26,5
32,0
6,6
6,8
6,8
2,8
2,8
2,6
3,2
3,2
3,1
0,0320
0,0430
0,0520
163
173
188
K8.R
180 M 2
22,0
2925
91,7
0,92
37,5
6,9
2,5
3,0
0,075
196
K8.R
K8.R
200 L 2
200 LX 2
30
37
2955
2955
92,5
93,0
0,90
0,90
52
64
7,2
7,2
2,6
2,7
2,9
3,0
0,130
0,160
254
278
K8.R
225 M 2
45
2960
93,0
0,89
78
7,1
2,5
3,0
0,240
400
K8.R
250 M 2
55
2970
93,8
0,89
95
7,1
2,4
2,8
0,400
545
K8.R
K8.R
280 S 2
280 M 2
75
90
2970
2970
94,5
94,5
0,90
0,90
127
153
6,8
6,6
2,2
2,4
2,7
2,8
0,650
0,780
700
762
K8.R
K8.R
K8.R
K8.R
K8.R
315
315
315
315
315
S2
M2
L2
LX 2
LY2
110
132
160
200
250
2975
2975
2975
2980
2980
95,0
95,5
95,7
95,8
96,0
0,90
0,90
0,90
0,90
0,91
186
220
270
335
415
6,3
6,8
6,9
6,9
7,2
2,0
2,1
2,4
2,3
1,7
2,4
2,5
2,7
2,6
2,7
1,40
1,60
1,70
2,20
2,80
960
1025
1065
1270
1420
K8.R
K8.R
355 M 2
355 L 2
315
355
2980
2985
96,8
96,8
0,92
0,93
510
570
6,7
6,9
1,5
1,4
2,8
2,7
4,50
5,00
1900
2050
K8.R
400 M 2
400
2990
96,9
0,94
635
6,7
1,1
2,8
7,50
2500
Other voltages and frequencies on inquiry
28
Motor selection data
Design point 400 V, 50 cps, EEx d, de
Three-phase motors with squirrel-cage rotor
Flame-proof enclosure type of protection EEx d II acc. to DIN EN 50014/50018
temperature class T4
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
J
m
kgm2
kg
Synchronous speed 1500 rpm - 4-pole design
K8.R
K8.R
63 K 4
63 L 4
0,12
0,18
1330
1350
52,0
60,0
0,73
0,74
0,48
0,59
2,7
3,1
2,2
2,0
2,6
2,5
0,00020
0,00025
13
14
K8.R
K8.R
71 K 4
71 L 4
0,25
0,37
1370
1380
64,0
70,0
0,80
0,80
0,70
0,95
3,5
3,6
2,0
2,2
2,5
2,6
0,00046
0,00063
16
17
K8.R
K8.R
80 K 4
80 L 4
0,55
0,75
1380
1400
73,0
75,0
0,80
0,79
1,36
1,83
3,8
4,2
2,0
2,1
2,3
2,5
0,00092
0,00130
24
25
K8.R
K8.R
90 L 4
90 LX 4
1,10
1,50
1400
1405
76,0
79,0
0,84
0,84
2,50
3,25
4,8
5,0
2,1
2,3
2,5
2,7
0,00210
0,00290
31
35
K8.R
K8.R
100 L 4
100 LX 4
2,2
3,0
1420
1415
80,0
80,5
0,80
0,82
4,95
6,6
5,4
5,5
2,4
2,3
2,8
2,7
0,00460
0,00560
44
46
K8.R
112 M 4
4,0
1435
85,0
0,84
8,1
6,8
2,7
3,2
0,01100
59
K8.R
K8.R
132 S 4
132 SX 4
5,5
7,5
1440
1440
86,5
88,0
0,86
0,86
10,7
14,3
6,2
6,5
2,5
2,7
2,7
2,8
0,0220
0,0300
100
110
K8.R
K8.R
160 M 4
160 MX 4
11,0
15,0
1460
1455
89,5
90,0
0,85
0,86
21,0
28,0
6,6
6,5
2,5
2,8
2,8
3,1
0,0570
0,0790
168
184
K8.R
K8.R
180 M 4
180 L 4
18,5
22,0
1460
1460
91,0
91,5
0,84
0,85
35,0
41,0
6,6
6,9
2,9
3,0
3,0
3,0
0,130
0,155
198
217
K8.R
200 L 4
30
1460
92,5
0,88
53
6,8
2,6
2,9
0,250
274
K8.R
K8.R
225 S 4
225 M 4
37
45
1465
1470
93,0
93,0
0,89
0,89
65
78
6,7
6,5
2,7
2,7
2,6
2,6
0,400
0,480
372
402
K8.R
250 M 4
55
1470
93,8
0,89
95
7,1
2,9
2,9
0,750
573
K8.R
K8.R
280 S 4
280 M 4
75
90
1480
1480
94,5
94,5
0,86
0,86
133
160
6,8
6,9
2,6
2,8
2,5
2,6
1,250
1,480
740
820
K8.R
K8.R
K8.R
K8.R
K8.R
315
315
315
315
315
S4
M4
L4
LX 4
LY 4
110
132
160
200
250
1485
1485
1485
1485
1485
95,1
95,3
95,6
95,8
96,0
0,86
0,86
0,87
0,87
0,89
194
230
280
345
420
6,7
6,8
6,9
6,9
7,3
2,5
2,5
2,6
2,6
1,7
2,6
2,7
2,6
2,6
2,7
2,20
2,70
3,10
3,90
4,60
1040
1120
1210
1430
1565
K8.R
K8.R
355 M 4
355 L 4
315
355
1490
1490
96,3
96,6
0,89
0,89
530
595
6,9
6,9
1,5
1,6
2,7
2,8
6,10
6,70
2050
2200
K8.R
K8.R
400 M 4
400 L 4
400
450
1495
1495
97,0
97,0
0,91
0,91
660
735
6,7
6,5
1,3
1,1
2,8
2,7
16,0
18,0
2650
2850
K8.R
K8.R
K8.R
450 M 4
450 L 4
450 LX 4
500
560
630
1495
1495
1495
97,2
97,4
97,4
0,91
0,91
0,91
815
6,9
6,8
6,8
1,0
1,0
1,0
2,7
2,7
2,7
23,0
26,0
31,0
3300
3500
3800
Other voltages and frequencies on inquiry
29
Motor selection data
Design point 400 V, 50 cps, EEx d, de
Three-phase motors with squirrel-cage rotor
Flame-proof enclosure type of protection EEx d II acc. to DIN EN 50014/50018
temperature class T4
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
J
m
kgm2
kg
Synchronous speed 1000 rpm - 6-pole design
K8.R
71 L 6
0,25
920
63,5
0,71
0,80
3,5
2,2
2,6
0,0012
17
K8.R
K8.R
80 K 6
80 L 6
0,37
0,55
925
925
68,0
70,0
0,72
0,72
1,11
1,58
4,1
4,0
2,5
2,4
2,8
2,7
0,0019
0,0025
24
25
K8.R
K8.R
90 L 6
90 LX 6
0,75
1,10
910
920
67,0
71,0
0,75
0,73
2,15
3,05
3,4
3,7
1,8
2,0
2,1
2,2
0,0033
0,0046
31
35
K8.R
100 L 6
1,5
945
77,0
0,75
3,75
4,9
2,5
3,0
0,0095
46
K8.R
112 M 6
2,2
950
81,0
0,74
5,30
5,6
2,7
3,1
0,0170
59
K8.R
K8.R
K8.R
132 S 6
132 M 6
132 MX 6
3,0
4,0
5,5
965
960
960
84,0
84,5
85,5
0,78
0,79
0,82
6,60
8,60
11,3
6,3
6,0
6,4
2,7
2,6
2,6
3,1
3,0
3,0
0,0310
0,0370
0,0430
100
104
112
K8.R
K8.R
160 M 6
160 L 6
7,5
11,0
960
965
86,5
87,5
0,85
0,85
14,7
21,5
6,8
6,7
2,5
2,5
3,3
3,2
0,0870
0,1200
170
190
K8.R
180 L 6
15,0
965
90,0
0,84
28,5
6,9
2,4
3,2
0,190
215
K8.R
K8.R
200 L 6
200 LX 6
18,5
22
975
970
90,5
91,0
0,84
0,84
35,0
41,5
6,2
6,8
1,9
2,2
2,7
3,0
0,280
0,310
270
280
K8.R
225 M 6
30
975
92,0
0,84
56
6,6
2,8
2,5
0,690
404
K8.R
250 M 6
37
980
92,5
0,85
68
6,6
2,8
2,6
1,03
570
K8.R
K8.R
280 S 6
280 M 6
45
55
985
985
93,3
93,5
0,83
0,83
84
102
5,8
5,8
2,8
2,7
2,4
2,3
1,35
1,70
720
770
K8.R
K8.R
K8.R
K8.R
K8.R
315
315
315
315
315
S6
M6
L6
LX 6
LY 6
75
90
110
132
160
990
990
990
990
990
94,6
95,0
95,2
95,4
95,4
0,87
0,88
0,88
0,88
0,88
132
155
190
225
275
6,4
6,5
6,5
6,7
6,8
2,6
2,6
2,7
2,7
2,6
2,4
2,4
2,5
2,5
2,5
4,30
5,00
6,00
7,30
8,30
995
1050
1145
1265
1440
K8.R
K8.R
355 M 6
355 L 6
200
250
990
990
95,6
95,9
0,88
0,88
345
430
6,7
6,7
1,8
1,8
2,7
2,7
11,3
13,8
1750
1950
K8.R
K8.R
400 M 6
400 L 6
315
355
993
994
96,3
96,6
0,89
0,89
530
595
6,5
6,7
1,0
1,1
2,6
2,7
23,0
27,0
2650
2850
K8.R
K8.R
K8.R
450 M 6
450 L 6
450 LX 6
400
450
500
995
995
995
96,8
96,6
97,0
0,90
0,89
0,89
665
755
6,9
6,8
6,8
1,0
1,2
1,1
2,6
2,8
2,7
41,0
46,0
x
3300
3600
3800
Other voltages and frequencies on inquiry
30
Motor selection data
Design point 400 V, 50 cps, EEx d, de
Three-phase motors with squirrel-cage rotor
Flame-proof enclosure type of protection EEx d II acc. to DIN EN 50014/50018
temperature class T4
with surface cooling, duty type S1, continuous duty
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
J
m
kgm2
kg
Synchronous speed 750 rpm - 8-pole design
K8.R
71 L 8
0,12
680
52,0
0,67
0,50
2,4
1,9
2,4
0,0012
17
K8.R
K8.R
80 K 8
80 L 8
0,18
0,25
690
690
61,0
62,0
0,65
0,64
0,66
0,91
3,2
3,2
2,2
2,2
2,6
2,5
0,0019
0,0025
24
25
K8.R
K8.R
90 L 8
90 LX 8
0,37
0,55
690
690
64,0
65,0
0,63
0,65
1,32
1,88
3,0
3,1
1,8
1,8
2,2
2,2
0,0033
0,0046
31
35
K8.R
K8.R
100 L 8
100 LX 8
0,75
1,10
710
695
71,0
70,0
0,67
0,73
2,30
3,10
4,0
3,8
2,4
2,0
2,6
2,4
0,0080
0,0095
44
46
K8.R
112 M 8
1,5
710
77,0
0,67
4,20
4,6
2,2
2,8
0,017
59
K8.R
K8.R
132 S 8
132 M 8
2,2
3,0
695
705
81,0
81,5
0,79
0,77
4,95
6,90
4,1
4,6
2,0
2,4
2,3
2,7
0,029
0,036
97
113
K8.R
K8.R
K8.R
160 M 8
160 MX 8
160 L 8
4,0
5,5
7,5
715
720
720
84,0
86,0
86,5
0,78
0,77
0,79
8,8
12,0
15,8
4,6
5,4
5,6
1,8
2,1
2,2
2,3
2,8
2,9
0,071
0,105
0,136
157
170
190
K8.R
180 L 8
11,0
725
88,5
0,80
22,5
6,4
2,4
3,0
0,22
215
K8.R
200 L 8
15,0
730
89,0
0,79
31,0
6,9
2,7
3,2
0,40
280
K8.R
K8.R
225 S 8
225 M 8
18,5
22
730
730
90,2
90,5
0,79
0,80
37,5
44,0
6,3
6,6
2,2
2,2
3,0
3,0
0,56
0,69
372
404
K8.R
250 M 8
30
735
92,1
0,80
59
6,8
2,0
3,0
1,20
550
K8.R
K8.R
280 S 8
280 M 8
37
45
735
735
92,8
92,8
0,82
0,82
70
84
6,2
6,3
2,1
2,0
2,8
2,6
1,90
2,30
740
800
K8.R
K8.R
K8.R
K8.R
K8.R
315
315
315
315
315
S8
M8
L8
LX 8
LY 8
55
75
90
110
132
740
740
740
740
740
93,5
93,7
94,0
94,2
94,2
0,83
0,84
0,84
0,83
0,85
102
138
165
205
245
6,0
6,3
6,5
6,6
6,7
2,5
2,5
2,6
2,7
2,5
2,6
2,5
2,6
2,7
2,5
4,30
5,00
6,00
7,30
8,30
995
1050
1145
1265
1440
K8.R
K8.R
355 M 8
355 L 8
160
200
740
745
95,1
95,5
0,83
0,83
295
365
6,4
6,6
1,9
1,7
2,4
2,5
11,4
13,9
1750
1950
K8.R
K8.R
400 M 8
400 L 8
250
315
745
745
96,0
96,2
0,83
0,84
455
565
6,1
6,2
1,2
1,2
2,4
2,4
23,0
30,0
2650
3100
K8.R
K8.R
K8.R
450 M 8
450 L 8
450 LX 8
355
400
450
745
745
745
96,5
96,6
96,7
0,84
0,84
0,84
630
710
800
6,1
6,1
6,1
1,0
1,0
1,0
2,3
2,2
2,2
46,0
51,0
57,0
3450
3750
4050
Other voltages and frequencies on inquiry
31
Constructive selection data
Dimensions
a1
P
b
A
b1
N
c
HA
c1
LA
d
D
d1
DA
e
BB
e1
M
f
AB
f1
T
g
AC
k
L
k1
LC
l
E
l1
EA
m
BA
n
AA
HD
HD
-
-
r
Pg
s
K
s1
K
t
GA
t1
GC
u
F
u1
FA
p (IM B5,
EEX d)
a
B
p (IM B3,
EEX d)
Size
p (IM B5)
Type
p (IM B3)
Three-phase motors with squirrel cage rotor, types K8.R
with surface cooling, type of cooling IC 411, degree of protection IP 55
flameproof enclosure type of protection
K8.R
63
K+L
80
140
100
95
10
9
11
11
100
115
130
3
136
246
274
23
23
30
30
213
220
213
220
2xM25x1,5
7
9,5
12,5
12,5
4
4
K8.R
71
K+L
90
160
112
110
10
9
14
14
110
130
140
3,5
150
282
301
30
30
30
30
228
237
228
237
2xM25x1,5
7
9,5
16
16
5
5
K8.R
80
K+L
100
200
125
130
12
12
19
19
130
165
160
3,5
168
314
354
40
40
35
35
255
295
255
295
2xM25x1,5
9,5
11,5
21,5
21,5
9,5
6
K8.R
90
L
125
200
140
130
12
12
24
24
155
165
180
3,5
188
358
402
50
50
40
40
268
300
268
300
2xM25x1,5
10,5
11,5
27
27
9,5
8
K8.R
100
L
140
250
160
180
15
16
28
28
175
215
200
4
208
414
484
60
60
45
45
298
335
298
335
2xM32x1,5
12
14
31
31
8
8
K8.R
112
M
140
250
190
180
17
16
28
28
175
215
235
4
230
432
500
60
60
50
50
308
348
308
348
2xM32x1,5
12
14
31
31
8
8
K8.R
K8.R
132
132
S
M
140
178
300
300
216
216
230
230
20
20
20
20
38
38
38
38
225
225
265
265
266
266
4
4
275
275
541
541
585
623
80
80
80
80
60
60
60
60
411
411
428
428
404
404
421
421
2xM32x1,5
2xM32x1,5
12
12
14
14
41
41
41
41
10
10
10
10
K8.R
K8.R
K8.R
K8.R
160
160
160
160
M...2,6,8
M...4
L...2,6,8
L...4
210
210
254
254
350
350
350
350
254
254
254
254
250
250
250
250
25
25
25
25
20
20
20
20
42
42
42
42
42
42
42
42
300
300
300
300
300
300
300
300
310
310
310
310
5
5
5
5
326
326
326
326
706
637
706
637
826
756
826
756
110
110
110
110
110
110
110
110
65
65
65
65
65
65
65
65
477
477
477
477
473
473
473
473
404
404
404
404
466
466
466
466
2xM40x1,5
2xM40x1,5
2xM40x1,5
2xM40x1,5
15
15
15
15
18
18
18
18
45
45
45
45
45
45
45
45
12
12
12
12
12
12
12
12
K8.R
K8.R
K8.R
K8.R
180
180
180
180
M...2
M...4,6,8
L... 2
L... 4,6,8
241
241
279
279
350
350
350
350
279
279
279
279
250
250
250
250
25
25
25
25
20
20
20
20
48
48
48
48
48
48
48
48
300
300
340
340
300
300
300
300
350
350
350
350
5
5
5
5
358
358
358
358
702
682
740
690
832
832
870
870
110
110
110
110
110
110
110
110
75
75
75
75
75
75
75
75
540
540
540
540
532
532
532
532
555
555
555
555
547
547
547
547
2xM40x1,5
2xM40x1,5
2xM40x1,5
2xM40x1,5
15
15
15
15
18
18
18
18
51,5
51,5
51,5
51,5
51,5
51,5
51,5
51,5
14
14
14
14
14
14
14
14
K8.R
200
L
305
400
318
300
30
20
55
55
365
350
390
5
400
813
933
110
110
90
80
576
575
591
560
2xM50x1,5
20
18
59
59
16
16
K8.R
K8.R
K8.R
K8.R
K8.R
225
225
225
225
225
S...4
S...8
M...2
M...4
M...6,8
286
286
311
311
311
450
450
450
450
450
356
356
356
356
356
350
350
350
350
350
32
32
32
32
32
22
22
22
22
22
60
60
55
60
60
60
60
55
60
60
370
370
395
395
395
400
400
400
400
400
450
450
450
450
450
5
5
5
5
5
455
455
455
455
455
890
835
910
940
890
1040
1040
1030
1090
1090
140
140
110
140
140
140
140
110
140
140
90
90
90
90
90
85
85
85
85
85
629
629
629
629
629
630
630
630
630
630
708
708
708
708
708
684
684
684
684
684
2xM50x1,5
2xM50x1,5
2xM50x1,5
2xM50x1,5
2xM50x1,5
20
20
20
20
20
18
18
18
18
18
64
64
59
64
64
64
64
59
64
64
18
18
16
18
18
18
18
16
18
18
K8.R
K8.R
K8.R
250
250
250
M...2
M...4
M...6,8
349
349
349
550
550
550
406
406
406
450
450
450
35
35
35
18
18
18
60
65
65
60
65
65
420
420
420
500
500
500
510
510
510
5
5
5
480
480
480
1005
1005
1025
1155
1155
1075
140
140
140
140
140
140
110
110
110
105
105
105
715
715
715
735
735
735
736
736
736
755
755
755
2xM 63x1,5
2xM 63x1,5
2xM 63x1,5
26
26
26
18
18
18
64
69
69
64
69
69
18
18
18
18
18
18
K8.R
K8.R
K8.R
K8.R
280
280
280
280
S...2
S...4,6,8
M...2
M...4,6,8
368
368
419
419
550
550
550
550
457
457
457
457
450
450
450
450
40
40
40
40
18
18
18
18
65
75
65
75
65
75
65
75
470
470
520
520
500
500
500
500
570
570
570
570
5
5
5
5
550
550
550
550
1070
1070
1130
1130
1220
1220
1280
1200
140
140
140
140
140
140
140
140
120
120
120
120
110
110
110
110
788
788
788
788
775
775
775
775
890
890
890
890
795
795
795
795
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
26
26
26
26
18
18
18
18
69
79,5
69
79,5
69
79,5
69
79,5
18
20
18
20
18
20
18
20
K8.R
K8.R
K8.R
K8.R
K8.R
K8.R
K8.R
K8.R
K8.R
K8.R
K8.R
K8.R
315
315
315
315
315
315
315
315
315
315
315
315
S...2
S...4
S...6,8
M...2
M...4
M...6,8
L...2
L...4
L...6,8
LX...2
LX...4
LX...6,8
406
406
406
457
457
457
508
508
508
508
508
508
660
660
660
660
660
660
660
660
660
660
660
660
508
508
508
508
508
508
508
508
508
508
508
508
550
550
550
550
550
550
550
550
550
550
550
550
30
30
30
30
30
30
30
30
30
30
30
30
22
22
22
22
22
22
22
22
22
22
22
22
65
80
80
65
80
80
65
80
80
65
80
80
65
80
80
65
80
80
65
80
80
65
80
80
520
520
520
570
570
570
621
621
621
621
621
621
550
550
550
550
550
550
550
550
550
550
550
550
630
630
630
630
630
630
630
630
630
630
630
630
6
6
6
6
6
6
6
6
6
6
6
6
635
635
635
635
635
635
635
635
635
635
635
635
1268
1298
1298
1268
1298
1298
1268
1298
1298
1368
1398
1398
1543
1573
1573
1543
1573
1573
1543
1573
1573
1643
1673
1673
140
170
170
140
170
170
140
170
170
140
170
170
140
170
170
140
170
170
140
170
170
140
170
170
140
140
140
140
140
140
140
140
140
140
140
140
130
130
130
130
130
130
130
130
130
130
130
130
885
885
885
885
885
885
885
885
885
885
885
885
895
895
895
895
895
895
895
895
895
895
895
895
945
945
945
945
945
945
945
945
945
945
945
945
915
915
915
915
915
915
915
915
915
915
915
915
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
2xM63x1,5
30
30
30
30
30
30
30
30
30
30
30
30
24
24
24
24
24
24
24
24
24
24
24
24
69
85
85
69
85
85
69
85
85
69
85
85
69
85
85
69
85
85
69
85
85
69
85
85
18
22
22
18
22
22
18
22
22
18
22
22
18
22
22
18
22
22
18
22
22
18
22
22
Tolerance for counter parts: H7
2nd shaft end only for direct coupling
32
Threaded center bores in the shaft end DIN 332-DS:
at diameter 11 up to 13 M4
at diameter 14 up to 16 M5
at diameter 17 up to 21 M6
at diameter 22 up to 24 M8
at diameter 25 up to 30 M10
at
at
at
at
at
diameter
diameter
diameter
diameter
diameter
31 up to 38
39 up to 50
51 up to 90
51 up to 90
100 M24
M12
M16
M20
M21
Dimensions for K8.R 315 LY, 355, 400, 450 on inquiry
33
Constructive selection data
34
Bearing arrangement
Size
pole number
DS-bearing
NS-bearing
63
2,4
6003 2ZR
6003 2ZR
71
2,4
6004 2ZR
6004 2ZR
80
2,4,6
6204 2ZR
6204 2ZR
90
2,4,6
6205 2ZR
6205 2ZR
100
2,4,6,8
6206 2ZR C3
6206 2ZR C3
112
2,4,6,8
6206 2ZR C3
6206 2ZR C3
132
2,4,6,8
6208 2ZR C3
6208 2ZR C3
160
2,4,6,8
6209 2ZR C3
6209 2ZR C3
180
2,4,6,8
6210 2ZR C3
6210 2ZR C3
200
2,4,6,8
6212 2ZR C3
6212 2ZR C3
225
2,4,6,8
6213 2ZR C3
6213 2ZR C3
250
2,4,6,8
6215 2ZR C3
6213 2ZR C3
280
2,4,6,8
6216 2ZR C3
6215 2ZR C3
315
315
2
4,6,8
6216 C4
6218 C4
6216 C4
6216 C4
355
355
2
4,6,8
6218 C4
6220 C4
6218 C4
6220 C4
Constructive selection data
Terminal box
Material
Size
Dimensions in mm
a
b
c
d
63
GG
140
140
80
70
71
GG
140
140
80
70
80
GG
145
145
70
53
90
GG
145
145
70
53
100
GG
145
145
70
53
112
GG
145
145
70
53
132
GG
220
220
110
110
160
GG
220
220
110
110
180
GG
265
270
162
133
200
GG
265
270
162
133
225
GG
380
380
203
190
250
GG
380
380
203
190
280
GG
380
380
203
190
315
GG
380
380
203
190
355
GG
583
489
255
242
35
Motor selection data
Design point 400 V, 50 cps, Ex II 3 G
Three-phase motors with squirrel-cage rotor
with surface cooling, duty type S1, continuous duty
motors for the use in zone 2
non-sparking type of protection Ex nA II acc. to IEC 79-15, temperature class T1-T3
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
max. T
J
m
°C
kgm2
kg
Synchronous speed 3000 rpm - 2-pole design
KPER
KPER
56 K2
56 G2
0,09
0,12
2865
2830
69,0
69,0
0,75
0,78
0,25
0,32
4,9
4,5
2,3
2,1
2,8
2,3
140
140
0,00013
0,00013
4,4
4,5
KPER
KPER
63 K2
63 G2
0,18
0,25
2790
2800
65,0
67,0
0,78
0,73
0,51
0,74
4,1
4,2
1,9
2,2
2,2
2,4
140
150
0,00013
0,00015
4,9
5,2
KPER
KPER
71 K2
71 G2
0,37
0,55
2780
2775
70,0
74,0
0,81
0,81
0,94
1,32
4,4
4,9
2,1
2,3
2,3
2,6
150
160
0,00025
0,00032
6,7
7,6
KPER
KPER
80 K2
80 G2
0,75
1,1
2825
2835
77,0
77,0
0,82
0,81
1,72
2,55
5,9
6,0
2,4
2,4
2,4
2,6
150
180
0,00057
0,00072
10,7
11,5
KPER
KPER
90 S2
90 L2
1,5
2,2
2850
2850
80,0
81,0
0,81
0,86
3,35
4,55
7,0
7,5
2,5
2,8
2,8
2,9
160
170
0,00132
0,00170
16
19
KPER
100 L2
3,0
2865
83,0
0,85
6,15
7,0
2,4
2,8
180
0,00275
25
KPER
112 M2
4,0
2900
83,0
0,83
8,4
7,0
2,2
2,9
170
0,0045
32
KPER
112 MX21)
5,5
2890
86,0
0,84
11
7,5
2,4
3,0
190
0,0055
38
K11R
132 SX2
7,5
2880
86,0
0,86
14,5
7,0
2,3
2,8
170
0,0110
57
K11R
K11R
K11R
160 M2
160 MX2
160 L2
11
15
18,5
2900
2920
2920
88,5
89,0
90,5
0,90
0,90
0,91
20,0
27,0
32,5
7,0
7,0
7,0
2,4
2,3
2,2
3,0
2,9
2,7
175
165
165
0,0258
0,0575
0,0675
81
118
134
K11R
180 M2
22
2935
91,5
0,92
37,5
6,0
1,8
2,5
165
0,105
165
K11R
K11R
200 L2
200 LX2
30
37
2935
2940
91,8
93,0
0,92
0,90
51,5
64,0
6,5
6,5
1,9
1,8
2,6
2,4
180
165
0,128
0,193
195
255
K11R
225 M2
45
2940
93,0
0,90
77,5
7,0
2,0
2,6
180
0,220
290
K11R
250 M2
55
2955
93,7
0,91
93,0
7,0
2,3
2,5
165
0,375
360
K11R
K11R
280 S2
280 M2
75
90
2965
2970
94,6
94,2
0,92
0,92
124
150
6,5
7,0
1,7
1,8
2,3
2,6
140
155
0,650
0,675
490
510
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
S2
M2
MX2
MY2
L2
110
132
160
200
250
2975
2975
2970
2965
2975
95,4
95,4
95,5
95,8
95,0
0,91
0,91
0,92
0,92
0,93
183
219
263
328
408
7,0
7,0
7,0
7,0
7,1
1,8
1,7
2,0
2,6
2,7
2,5
2,4
2,5
2,7
2,4
150
160
150
165
180
1,21
1,44
1,76
2,82
3,66
720
800
980
1170
1395
K12R
K12R
K12R
K12R
355
355
355
355
M2
MX2
LY2
L2
315
355
400
450
2985
2985
2985
2985
96,8
96,9
97,1
97,2
0,91
0,91
0,91
0,92
520
580
650
725
8,2
8,5
8,6
9,0
1,4
1,4
1,6
2,0
3
2,9
2,9
2,8
150
170
180
190
4,2
5,6
7,1
7,1
2000
2200
2400
2400
max. T: maximum surface temperature (incl. rotor)
1)
also available as K11R 132 S2
36
Motor selection data
Design point 400 V, 50 cps, Ex II 3 G
Three-phase motors with squirrel-cage rotor
with surface cooling, duty type S1, continuous duty
motors for the use in zone 2
non-sparking type of protection Ex nA II acc. to IEC 79-15, temperature class T1-T3
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
max. T
J
m
°C
kgm2
kg
Synchronous speed 1500 rpm - 4-pole design
KPER
KPER
56 K4
56 G4
0,06
0,09
1410
1375
59,0
60,0
0,61
0,70
0,24
0,31
3,1
3,2
2,3
1,9
2,7
2,2
140
140
0,00019
0,00019
4,3
4,4
KPER
KPER
63 K4
63 G4
0,12
0,18
1370
1360
56,0
58,0
0,70
0,69
0,44
0,65
3,2
3,3
1,9
2,0
2,2
2,3
150
160
0,00019
0,00024
4,8
5,2
KPER
KPER
71 K4
71 G4
0,25
0,37
1385
1370
64,0
66,0
0,72
0,76
0,78
1,06
3,6
3,8
1,8
2,0
2,1
2,2
140
160
0,00040
0,00050
6,8
7,8
KPER
KPER
80 K4
80 G4
0,55
0,75
1400
1400
69,0
72,0
0,72
0,72
1,60
2,10
4,1
4,6
2,1
2,2
2,3
2,3
180
160
0,00087
0,00107
10,6
11,7
KPER
KPER
90 S4
90 L4
1,10
1,50
1410
1400
76,0
77,0
0,80
0,83
2,62
3,40
5,5
5,5
2,3
2,5
2,5
2,6
150
160
0,00207
0,00260
15,5
18
KPER
KPER
100 L4
100 LX4
2,20
3,00
1420
1430
79,0
82,6
0,78
0,79
5,15
6,65
6,0
6,4
3,0
2,3
3,1
2,8
170
170
0,00400
0,00725
23,5
30
KPER
KPER
112 M4
112 MX41)
4,00
5,5
1435
1425
83,0
84,0
0,79
0,78
8,80
12,1
6,9
6,3
2,6
2,5
3,0
2,9
180
195
0,0090
0,0110
37
45
K11R
132 M4
7,5
1440
85,0
0,82
15,5
5,5
2,0
2,4
160
0,028
69
K11R
K11R
160 M4
160 L4
11,0
15,0
1440
1455
87,0
89,0
0,83
0,86
22,0
28,5
6,0
6,0
2,1
2,1
2,4
2,5
165
170
0,035
0,078
86
120
K11R
K11R
180 M4
180 L4
18,5
22
1455
1470
90,0
90,5
0,86
0,86
34,5
41,0
6,0
6,5
2,3
2,2
2,5
2,6
180
180
0,090
0,138
136
170
K11R
200 L4
30
1465
91,5
0,87
54,5
6,0
2,0
2,4
190
0,168
200
K11R
K11R
225 S4
225 M4
37
45
1470
1470
92,5
93,0
0,86
0,86
67,0
81,0
6,5
6,5
2,0
2,2
2,5
2,5
180
195
0,275
0,313
270
300
K11R
250 M4
55
1475
93,5
0,86
98,5
7,0
2,4
2,3
180
0,525
375
K11R
K11R
280 S4
280 M4
75
90
1480
1480
94,1
94,6
0,86
0,86
134
160
7,0
7,0
2,0
2,1
2,2
2,2
170
175
0,950
1,100
520
580
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
S4
M4
MX4
MY4
L4
110
132
160
200
250
1480
1480
1480
1480
1480
94,8
95,0
95,0
95,5
95,0
0,86
0,87
0,87
0,88
0,89
195
231
279
343
427
7,0
7,0
6,5
6,8
7,7
2,1
2,1
1,8
2,0
1,8
2,4
2,4
2,2
2,4
2,2
160
160
170
180
180
1,96
2,27
2,73
4,82
5,93
740
840
1000
1200
1410
K12R
K12R
K12R
K12R
355
355
355
355
M4
MX4
LY4
L4
315
355
400
450
1495
1495
1495
1490
96,8
96,8
96,8
96,7
0,85
0,84
0,82
0,79
555
630
730
850
9,0
9,2
9,0
8,7
2,0
2,0
2,1
1,9
3,4
3,8
4,0
4,0
150
160
170
185
5,6
7,9
9,5
9,5
1950
2150
2400
2400
max. T: maximum surface temperature (incl. rotor)
1)
also available as K11R 132 S2
37
Motor selection data
Design point 400 V, 50 cps, Ex II 3 G
Three-phase motors with squirrel-cage rotor
with surface cooling, duty type S1, continuous duty
motors for the use in zone 2
non-sparking type of protection Ex nA II acc. to IEC 79-15, temperature class T1-T3
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
max. T
J
m
°C
kgm2
kg
Synchronous speed 1000 rpm - 6-pole design
KPER
KPER
63 K6
63 G6
0,09
0,12
895
880
48,0
50,0
0,59
0,59
0,46
0,59
2,5
2,5
2,0
2,0
2,4
2,3
150
160
0,00024
0,00027
4,9
5,7
KPER
KPER
71 K6
71 G6
0,18
0,25
925
915
57,0
59,0
0,52
0,56
0,88
1,10
2,8
2,9
1,6
2,0
2,1
2,2
160
180
0,00045
0,00060
7,4
8,3
KPER
KPER
80 K6
80 G6
0,37
0,55
915
915
63,0
67,0
0,70
0,69
1,22
1,73
3,4
3,7
2,0
2,2
2,0
2,4
150
170
0,00130
0,00175
11
12,5
KPER
KPER
90 S6
90 L6
0,75
1,10
935
935
69,0
73,0
0,65
0,69
2,43
3,15
4,5
4,6
2,4
2,2
2,6
2,4
140
180
0,00325
0,00425
16
19
KPER
100 L6
1,50
945
76,0
0,73
3,90
4,6
2,1
2,4
160
0,00625
24
KPER
112 M6
2,20
950
78,0
0,76
5,35
5,3
2,2
2,7
150
0,01225
33,5
K11R
K11R
K11R
132 S6
132 M6
132 MX6
3,0
4,0
5,5
950
950
955
78,0
80,0
83,0
0,81
0,80
0,83
6,9
9,0
11,5
5,5
6,0
5,0
2,0
2,3
1,9
2,8
3,0
2,4
130
130
140
0,0180
0,0230
0,0430
46
53
70
K11R
K11R
160 M6
160 L6
7,5
11,0
960
965
85,0
85,0
0,82
0,85
15,5
22,0
5,5
5,0
2,0
2,0
2,5
2,3
150
165
0,0530
0,113
86
114
K11R
180 L6
15,0
965
86,0
0,83
30,5
5,5
2,4
2,7
180
0,145
136
K11R
K11R
200 L6
200 LX6
18,5
22
965
970
88,0
88,5
0,87
0,87
35,0
41,0
5,5
6,0
2,0
2,2
2,4
2,7
170
180
0,228
0,268
175
200
K11R
K11R
225 M6
250 M6
30
37
973
973
90,3
91,0
0,87
0,89
55,0
66,0
6,0
6,0
2,2
2,0
2,5
2,3
180
165
0,443
0,825
265
360
K11R
K11R
280 S6
280 M6
45
55
980
980
92,0
92,5
0,87
0,88
81,0
97,5
6,0
6,0
2,0
2,1
2,0
2,2
155
155
1,28
1,48
465
520
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
S6
M6
MX6
MY6
L6
75
90
110
132
160
985
990
985
985
985
93,5
94,0
94,0
95,0
93,5
0,87
0,88
0,88
0,88
0,87
133
157
192
228
284
6,5
6,5
7,0
7,0
7,0
2,0
2,0
2,3
2,4
2,1
2,4
2,4
2,6
2,6
2,4
140
140
165
165
180
2,63
3,33
3,60
6,00
6,76
690
800
880
1050
1155
K12R
K12R
K12R
355 M6
355 MX6
355 LY6
200
250
315
995
995
995
96,0
96,6
96,6
0,84
0,85
0,84
360
440
560
9,2
9,0
8,8
2,0
2,0
2,0
3,5
3,2
3,4
190
190
190
8,2
12,1
14,0
1650
2200
2400
max. T: maximum surface temperature (incl. rotor)
38
Motor selection data
Design point 400 V, 50 cps, Ex II 3 G
Three-phase motors with squirrel-cage rotor
with surface cooling, duty type S1, continuous duty
motors for the use in zone 2
non-sparking type of protection Ex nA II acc. to IEC 79-15, temperature class T1-T3
insulation class F, degree of protection IP 54, 50 cps
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
MA/M
MK/M
max. T
J
m
°C
kgm2
kg
Synchronous speed 750 rpm - 8-pole design
KPER 71 K8
KPER 71 G8
0,09
0,12
675
670
43,0
44,0
0,54
0,54
0,56
0,73
2,1
2,3
1,9
1,8
2,1
2,1
160
160
0,00050
0,00060
6,6
8,1
KPER 80 K8
KPER 80 G8
0,18
0,25
690
695
55,0
56,0
0,61
0,58
0,78
1,12
2,8
3,0
2,0
2,3
2,2
2,5
140
140
0,00130
0,00175
10,5
12
KPER 90 S8
KPER 90 L8
0,37
0,55
700
695
59,0
63,0
0,57
0,62
1,6
2,04
3,0
3,2
1,9
1,9
2,1
2,2
150
160
0,00300
0,00375
15
18
KPER 100 L8
KPER 100 LX8
0,75
1,1
705
705
67,0
72,0
0,60
0,68
2,7
3,25
3,3
4,0
2,0
2,0
2,3
2,4
160
150
0,00625
0,00900
23
28
KPER 112 M8
1,5
705
75,0
0,71
4,1
4,4
2,2
2,5
150
0,01225
33,5
K11R
K11R
132 S8
132 M8
2,2
3,0
705
700
75,0
78,0
0,75
0,75
5,6
7,4
4,0
4,0
1,7
1,7
2,3
2,3
125
135
0,0180
0,0230
46
53
K11R
K11R
K11R
160 M8
160 MX8
160 L8
4,0
5,5
7,5
710
710
720
79,0
80,0
83,0
0,76
0,76
0,78
9,6
13,0
16,5
4,0
4,0
4,5
1,6
1,7
1,8
1,9
2,1
2,1
140
140
150
0,0430
0,0530
0,1130
70
86
114
K11R
180 L8
11,0
720
85,0
0,78
24,0
4,5
2,0
2,1
165
0,1450
136
K11R
200 L8
15,0
18,5
725
725
86,5
86,5
0,78
0,78
32,0
39,5
5,0
5,0
2,0
2,0
2,3
2,3
160
185
0,2280
0,2680
175
200
K11R
K11R
225 S8
225 M8
18,5
22
725
730
88,0
89,0
0,80
0,80
38,0
44,5
5,0
5,0
2,0
2,0
2,2
2,4
175
175
0,440
0,440
265
265
K11R
250 M8
30
730
90,0
0,80
60,0
5,5
2,2
2,2
165
0,825
360
K11R
K11R
280 S8
280 M8
37
45
735
735
91,0
91,5
0,80
0,77
73,5
92,0
5,5
5,5
2,0
2,2
2,0
2,0
155
155
1,350
1,550
465
520
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
S8
M8
MX8
MY8
L8
55
75
90
110
132
740
740
740
740
740
92,5
93,3
93,5
94,5
93,0
0,80
0,81
0,81
0,81
0,79
107
143
172
207
259
6,0
6,0
6,0
6,0
5,8
2,0
2,0
2,0
2,4
2,0
2,4
2,3
2,4
2,6
2,1
130
140
160
165
180
2,63
3,33
3,60
6,00
6,76
690
800
880
1050
1155
K12R
K12R
K12R
355 M8
355 MX8
355 LY8
160
200
250
745
745
745
95,6
95,9
95,8
0,77
0,79
0,74
315
380
510
7,5
8,2
8,0
1,8
2,0
2,2
3,0
3,5
3,5
180
190
190
9,5
13,4
15,8
1600
2200
2400
max. T: maximum surface temperature (incl. rotor)
39
Motor selection data
Design point 400 V, 50 cps, Ex II 2 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 21 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 65,
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 3000 rpm - 2-pole design
KPER
KPER
56 K2
56 G2
0,09
0,12
2865
2830
69,0
69,0
0,75
0,78
0,25
0,32
4,9
4,5
0,00013
0,00013
4,4
4,5
KPER
KPER
63 K2
63 G2
0,18
0,25
2790
2800
65,0
67,0
0,78
0,73
0,51
0,74
4,1
4,2
0,00013
0,00015
4,9
5,2
KPER
KPER
71 K2
71 G2
0,37
0,55
2780
2775
70,0
74,0
0,81
0,81
0,94
1,32
4,4
4,9
0,00025
0,00032
6,7
7,6
KPER
KPER
80 K2
80 G2
0,75
1,1
2825
2835
77,0
77,0
0,82
0,81
1,72
2,55
5,9
6,0
0,00057
0,00072
10,7
11,5
KPER
KPER
90 S2
90 L2
1,5
2,2
2850
2850
80,0
81,0
0,81
0,86
3,35
4,55
7,0
7,5
0,00132
0,0017
16
19
KPER
100 L2
3,0
2865
83,0
0,85
6,15
7,0
0,00275
25
KPER
112 M2
4,0
2900
83,0
0,83
8,4
7,0
0,0045
32
KPER
K11Q
132 S2T1)
132 SX2
5,5
7,5
2890
2900
86,0
87,0
0,84
0,86
11
15
7,5
6,5
0,0055
0,0110
40
57
K11Q
K11Q
K11Q
160 M2
160 MX2
160 L2
11,0
15,0
18,5
2910
2930
2920
87,0
88,8
90,5
0,92
0,90
0,92
20
27
32
7,5
7,1
7,2
0,0258
0,0575
0,0675
81
118
134
K11Q
180 M2
22
2935
91,8
0,92
37,5
6,8
0,1050
165
K11Q
K11Q
200 L2
200 Lx2
30
37
2940
2940
92,8
93,0
0,92
0,90
50,5
64
7,3
7,0
0,1280
0,1930
195
255
K11Q
225 M2
45
2940
93,7
0,91
76
7,5
0,2200
290
K11Q
250 M2
55
2955
93,7
0,91
93
7,5
0,3750
360
K11Q
K11Q
280 S2
280 M2
75
90
2970
2970
94,6
94,7
0,92
0,91
124
151
7,5
8,5
0,6500
0,6750
490
510
K11Q
K11Q
K11Q
K11Q
K11Q
K11Q
315
315
315
315
315
315
110
132
160
200
250
315
2975
2975
2975
2970
2973
2975
95,4
95,4
96,0
96,0
96,1
96,7
0,91
0,91
0,93
0,92
0,93
0,92
183
219
259
327
404
511
8,5
8,5
8,5
8,2
7,3
7,4
1,210
1,440
1,760
2,820
3,66
4,43
720
800
980
1170
1460
1630
1)
S2
M2
MX2
MY2
L2
LX2
also available as K11Q 132 S2
40
Motor selection data
Design point 400 V, 50 cps, Ex II 2 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 21 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 65,
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 1500 rpm - 4-pole design
KPER
KPER
56 K4
56 G4
0,06
0,09
1410
1375
59,0
60,0
0,61
0,70
0,24
0,31
3,1
3,2
0,00019
0,00019
4,3
4,4
KPER
KPER
63 K4
63 G4
0,12
0,18
1370
1360
56,0
58,0
0,70
0,69
0,44
0,65
3,2
3,3
0,00019
0,00024
4,8
5,2
KPER
KPER
71 K4
71 G4
0,25
0,37
1385
1370
64,0
66,0
0,72
0,76
0,78
1,06
3,6
3,8
0,00040
0,00050
6,8
7,8
KPER
KPER
80 K4
80 G4
0,55
0,75
1400
1400
69,0
72,0
0,72
0,72
1,60
2,10
4,1
4,6
0,00087
0,00107
10,6
11,7
KPER
KPER
90 S4
90 L4
1,10
1,50
1410
1400
76,0
77,0
0,80
0,83
2,62
3,40
5,5
5,5
0,00207
0,00260
15,5
18
KPER
KPER
100 L4
100 LX4
2,20
3,00
1420
1430
79,0
82,6
0,78
0,79
5,15
6,65
6,0
6,4
0,00400
0,00725
23,5
30
KPER
112 M4
4,00
1435
83,0
0,79
8,80
6,9
0,00900
37
K11Q
K11Q
132 S4T1)
132 M4
5,5
7,5
1425
1450
85,0
86,0
0,79
0,84
11,80
15
6,3
6,0
0,01100
0,0280
47
70
K11Q
K11Q
160 M4
160 L4
11,0
15,0
1450
1465
86,0
88,0
0,85
0,86
21,5
28,5
6,8
7,3
0,0350
0,0780
92
120
K11Q
K11Q
180 M4
180 L4
18,5
22
1460
1465
88,5
90,5
0,86
0,84
35
42
6,8
6,5
0,0900
0,1380
136
170
K11Q
200 L4
30
1465
91,5
0,85
55,5
7,0
0,1680
200
K11Q
K11Q
225 S4
225 M4
37
45
1470
1470
92,5
93,0
0,86
0,86
67
81
7,0
7,0
0,2750
0,3130
270
300
K11Q
250 M4
55
1475
93,5
0,86
98,5
7,0
0,5250
375
K11Q
K11Q
280 S4
280 M4
75
90
1480
1480
94,1
94,6
0,86
0,86
134
160
7,0
7,0
0,950
1,100
520
580
K11Q
K11Q
K11Q
K11Q
K11Q
K11Q
315
315
315
315
315
315
110
132
160
200
250
315
1485
1485
1480
1485
1485
1490
95,1
95,1
95,0
96,0
96,1
96,5
0,86
0,86
0,87
0,88
0,90
0,88
194
233
279
342
417
535
7,5
7,0
7,0
7,5
8,0
8,6
1,960
2,270
2,730
4,820
5,93
6,82
740
840
1000
1200
1450
1630
1)
S4
M4
MX4
MY4
L4
LX4
also available as K11Q 132 S2
41
Motor selection data
Design point 400 V, 50 cps, Ex II 2 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 21 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 65,
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 1000 rpm - 6-pole design
KPER
KPER
63 K6
63 G6
0,09
0,12
895
880
48,0
50,0
0,59
0,59
0,46
0,59
2,5
2,5
0,00024
0,00027
4,9
5,7
KPER
KPER
71 K6
71 G6
0,18
0,25
925
915
57,0
59,0
0,52
0,56
0,88
1,10
2,8
2,9
0,00045
0,00060
7,4
8,3
KPER
KPER
80 K6
80 G6
0,37
0,55
915
915
63,0
67,0
0,70
0,69
1,22
1,73
3,4
3,7
0,00130
0,00175
11
12,5
KPER
KPER
90 S6
90 L6
0,75
1,10
935
935
69,0
73,0
0,65
0,69
2,43
3,15
4,5
4,6
0,00325
0,00425
16
19
KPER
100 L6
1,50
945
76,0
0,73
3,90
4,6
0,00625
24
KPER
112 M6
2,20
950
78,0
0,76
5,35
5,3
0,01225
33,5
K11Q
K11Q
K11Q
132 S6
132 M6
132 MX6
3,0
4,0
5,5
955
955
955
78,2
80,0
83,0
0,82
0,80
0,83
6,8
9
11,5
5,4
6,0
5,0
0,0180
0,0230
0,0430
46
53
70
K11Q
K11Q
160 M6
160 L6
7,5
11,0
960
965
85,0
85,2
0,82
0,86
15,5
21,5
5,5
5,0
0,0530
0,1130
86
114
K11Q
180 L6
15,0
965
86,0
0,83
30,5
6,0
0,1450
136
K11Q
K11Q
200 L6
200 LX6
18,5
22
970
970
88,1
88,8
0,87
0,87
35,0
41
5,5
6,2
0,2280
0,2680
175
200
K11Q
225 M6
30
973
90,4
0,89
54
6,5
0,4430
265
K11Q
250 M6
37
975
91,0
0,89
66
6,5
0,8250
360
K11Q
K11Q
280 S6
280 M6
45
55
980
980
92,0
92,5
0,87
0,88
81
97,5
6,0
6,5
1,280
1,480
465
520
K11Q
K11Q
K11Q
K11Q
K11Q
K11Q
315
315
315
315
315
315
75
90
110
132
160
200
985
990
990
990
985
990
93,7
94,4
94,0
95,0
95,3
95,0
0,87
0,88
0,88
0,88
0,89
0,87
133
156
192
228
272
349
7,0
7,0
7,5
7,5
7,5
8,3
2,630
3,330
3,60
6,00
6,67
8,60
690
800
880
1050
1250
1460
42
S6
M6
MX6
MY6
L6
LX6
Motor selection data
Design point 400 V, 50 cps, Ex II 2 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 21 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 65,
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 750 rpm - 8-pole design
KPER
KPER
71 K8
71 G8
0,09
0,12
675
670
43,0
44,0
0,54
0,54
0,56
0,73
2,1
2,3
0,00050
0,00060
6,6
8,1
KPER
KPER
80 K8
80 G8
0,18
0,25
690
695
55,0
56,0
0,61
0,58
0,78
1,12
2,8
3,0
0,00130
0,00175
10,5
12
KPER
KPER
90 S8
90 L8
0,37
0,55
700
695
59,0
63,0
0,57
0,62
1,6
2,04
3,0
3,2
0,00300
0,00375
15
18
KPER
KPER
100 L8
100 LX8
0,75
1,1
705
705
67,0
72,0
0,60
0,68
2,7
3,25
3,3
4,0
0,00625
0,00900
23
28
KPER
112 M8
1,5
705
75,0
0,71
4,1
4,4
0,01225
33,5
K11Q
K11Q
132 S8
132 M8
2,2
3,0
705
705
75,5
78,0
0,76
0,75
5,5
7,4
4,5
4,5
0,0180
0,0230
46
53
K11Q
K11Q
K11Q
160 M8
160 MX8
160 L8
4,0
5,5
7,5
710
710
725
79,3
81,4
83,0
0,78
0,78
0,78
9,3
12,5
16,5
4,0
4,5
4,5
0,0430
0,0530
0,1130
70
86
114
K11Q
180 L8
11,0
720
85,0
0,78
24
4,5
0,1450
136
K11Q
200 L8
15,0
725
86,5
0,79
31,5
5,0
0,2280
175
K11Q
K11Q
225 S8
225 M8
18,5
22
725
725
89,2
89,2
0,83
0,84
36
42,5
5,5
5,0
0,4400
0,4400
265
265
K11Q
250 M8
30
730
90,2
0,79
61
5,5
0,8250
360
K11Q
K11Q
280 S8
280 M8
37
45
735
735
91,0
91,5
0,80
0,77
73,5
92
5,5
6,0
1,350
1,550
465
520
K11Q
K11Q
K11Q
K11Q
K11Q
K11Q
315
315
315
315
315
315
55
75
90
110
132
160
740
740
740
740
740
740
93,1
93,3
93,5
94,6
95,0
95,2
0,80
0,81
0,81
0,81
0,83
0,79
107
143
172
207
242
307
6,5
6,0
6,0
6,5
6,3
7,2
2,630
3,330
3,60
6,00
6,76
8,71
690
800
880
1050
1250
1430
S8
M8
MX8
MY8
L8
LX8
43
Motor selection data
Tolerance for counter parts H7
2nd shaft end only for direct coupling
Bl = minimum distance for air inlet
= air inlet
→
44
–
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
c1
LA
9
9
9
9
9
9
10
10
10
10
11
11
11
11
11
12
12
12
12
12
12
13
13
13
13
13
13
13
13
15
15
15
16
16
16
16
18
18
18
18
18
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
d
D
9
9
11
11
14
14
19
19
24
24
28
28
28
28
28
38
38
38
38
38
38
42
42
42
42
48
48
48
48
55
55
55
60
55
60
60
60
65
65
75
65
75
65
80
65
80
65
80
80
80
65
80
65
80
65
80
80
–
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
d1
DA
9
11
11
14
14
19
19
22
22
24
28
28
28
28
32
32
32
38
38
32
38
38
42
42
48
42
48
42
48
48
55
55
55
55
55
55
55
65
65
65
65
65
70
65
70
65
70
70
70
65
70
65
70
65
70
70
–
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
e
BB
86
86
100
100
116
116
125
125
130
155
175
171
180
180
180
180
180
180
218
218
218
257
257
257
301
288
288
326
326
360
360
360
343
368
368
368
412
412
431
431
482
482
503
503
554
554
554
554
554
554
573
573
624
624
624
624
624
e1
M
115
115
115
115
130
130
165
165
165
165
215
215
215
215
215
265
265
265
265
265
265
300
300
300
300
300
300
300
300
350
350
350
400
400
400
400
500
500
500
500
500
500
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
f
AB
110
110
128
128
138
138
168
168
178
178
192
188
224
224
224
256
256
256
256
256
256
296
296
296
296
328
328
328
328
372
372
372
413
413
413
413
471
471
522
522
522
522
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
f1
T
3
3
3
3
3,5
3,5
3,5
3,5
3,5
3,5
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
g
AC
109
109
109
109
124
124
139
139
157
157
177
196
196
196
196
217
217
217
258
258
217
258
258
313
313
351
313
351
313
351
351
390
390
390
390
390
440
440
490
490
490
490
550
550
550
550
550
550
550
550
610
610
610
610
610
610
610
g1 g1*
– –
178
178
178
200
200
178
200
200
242
242
261
242
261
242
261
261
300
300
300
300
300
326
326
388
388
388
388
420
420
420
420
420
420
420
420
487
487
487
487
487
487
487
218
218
218
240
240
218
240
240
288
288
307
288
307
288
307
307
358
358
358
358
358
384
384
426
426
426
426
465
465
465
465
465
465
465
465
h
H
56
56
63
63
71
71
80
80
90
90
100
100
112
112
112
132
132
132
132
132
132
160
160
160
160
180
180
180
180
200
200
200
225
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
Threaded center bores in the shaft end DIN 332-DS:
at diameter 11 up to 13 M4
at diameter 14 up to 16 M5
at diameter 17 up to 21 M6
at diameter 22 up to 24 M8
at diameter 25 up to 30 M10
–
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
at
at
at
at
at
k k1 l
L LC E
173 - 20
179 219 20
179 205 23
179 205 23
206 238,5 30
206 238,5 30
249 293 40
249 293 40
276 330 50
298 352 50
332 386 60
359 425 60
359 425 60
393 459 60
410 478 60
459 542 80
479 562 80
459 542 80
481 565 80
481 565 80
479 562 80
559 643 110
559 643 110
571 686 110
609 724 110
635 751 110
609 724 110
680 796 110
609 724 110
680 796 110
680 796 110
727 851 110
757 881 140
767 891 110
797 921 140
757 881 140
862 977 140
862 977 140
924 1072 140
924 1072 140
970 1118 140
970 1118 140
1065 1218 140
1095 1248 170
1120 1273 140
1150 1303 170
1200 1353 140
1230 1383 170
1150 1303 170
1150 1303 170
1270 1448 140
1300 1478 170
1390 1568 140
1420 1598 170
1510 1688 140
1540 1718 170
1420 1598 170
diameter
diameter
diameter
diameter
diameter
l1
EA
20
23
23
30
30
40
40
50
50
60
60
60
60
60
80
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
m m1 n o
BA
AA –
18
18
28
28
32
32
38
38
40
40
45
33 123,5
50 123,5
50 157,5
50 174
55
50 168
55
50 188
55
50 168
55
50 173
55
50 173
55
50 188
60
55 221
60
55 221
60
55 211
60
55 249
65
62 239
65
62 249
65
62 284
65
62 249
70
70 284
70
70 284
70
70 292
75
75 292
75
75 332
75
75 332
75
75 292
84
84 382
84
84 382
96
94 383
96
94 383
96
94 429
96
94 429
120
126 519
120
126 519
120
126 574
120
126 574
120
126 654
120
126 654
120
126 574
120
126 574
120
110 630
120
110 630
120
110 645
120
110 645
120
110 765
120
110 765
120
110 645
31 up to 38
39 up to 50
51 up to 90
51 up to 90
100 M24
M12
M16
M20
M21
HD
154
154
161
161
175
175
191
191
210
210
227
237
249
249
269
310
310
310
332
332
310
360
360
402
402
441
422
441
422
461
461
500
525
525
525
525
576
576
668
668
668
668
735
735
735
735
735
735
735
735
802
802
802
802
802
802
802
–
–
–
350
350
350
372
372
350
400
400
448
448
487
468
487
468
507
507
558
583
583
583
583
634
634
716
716
716
716
790
790
790
790
790
790
790
790
p(I) p(I)* p(II) p(II)* q
HD – HD – –
328
328
328
350
350
328
375
375
417
417
436
417
436
417
461
461
500
525
525
525
525
601
601
663
663
663
663
750
750
750
750
750
750
750
750
827
827
827
827
827
827
827
368
368
368
390
390
368
415
415
563
563
482
463
482
463
507
507
558
583
583
583
583
659
659
701
701
701
701
805
805
805
805
805
805
805
805
–
M20
M20
M20
M20
M20
M20
M20
M20
M25
M25
M25
235,5 M25
235,5 M25
235,5 M25
235,5 M25
291 M32
291 M32
291 M32
308 M32
308 M32
291 M32
338 M32
338 M32
360 M40
360 M40
396 M40
360 M40
396 M40
360 M40
396 M50
396 M50
435 M50
465 M50
435 M50
465 M50
465 M50
480 M50
480 M50
541 M63
541 M63
541 M63
541 M63
546 M63
576 M63
546 M63
576 M63
546 M63
576 M63
576 M63
576 M63
640 M63
670 M63
745 M63
775 M63
745 M63
775 M63
775 M63
r(II) r(II)*
–
M40
M40
M40
M40
M40
M40
M40
M40
M50
M50
M50
M50
M50
M50
M50
M50
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
* Design with larger terminal box
** Design with VIK terminal box with entry bush
I Terminal box for threaded joint
2) Conduit according to cable diameter max. 83 mm
3) Thread lead … x 1,5
s
K
6
6
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
19
19
19
19
19
19
19
24
24
24
24
24
24
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
s1
S
9
9
9
9
9
9
11
11
11
11
14
14
14
14
14
14
14
14
14
14
14
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
t
GA
10
10
13
13
16
16
22
22
27
27
31
31
31
31
31
41
41
41
41
41
41
45
45
45
45
51,5
51,5
51,5
51,5
59
59
59
64
59
64
64
64
69
69
79,5
69
79,5
69
85
69
85
69
85
85
85
69
85
69
85
69
85
85
t1
GC
10
13
13
16
16
22
22
25
25
27
31
31
31
31
35
35
35
41
41
35
41
41
45
45
51,5
45
51,5
45
51,5
51,5
59
59
59
59
59
59
59
69
69
69
69
69
74,5
69
74,5
69
74,5
74,5
74,5
69
74,5
69
74,5
69
74,5
74,5
u u1 w1 w2 A
F FA C CA –
3
- 36 - 57
3
3 36 52 57
4
4 40 39 57,5
4
4 40 39 57,5
5
5 45 43,5 61
5
5 45 43,5 61
6
6 50 63 67
6
6 50 63 67
8
6 56 74 70
8
6 56 71 70
8
8 63 73 75
8
8 63 102 77
8
8 70 95 77
8
8 70 129 77
8
8 70 129 77
10 10 89 153 108
10 10 89 173 108
10 10 89 153 108
10 10 89 138 114
10 10 89 138 114
10 10 89 135 108
12 10 108 135 135
12 10 108 135 135
12 12 108 148 138
12 12 108 142 138
14 14 121 169 147
14 12 121 142 138
14 14 121 176 147
14 12 121 104 138
16 14 133 138 147
16 14 133 138 147
16 16 133 193 168
18 16 149 196 168
16 16 149 211 168
18 16 149 211 168
18 16 149 171 168
18 16 168 210 177
18 16 168 210 177
18 18 190 234 206
20 18 190 234 206
18 18 190 229 206
20 18 190 229 206
18 18 216 316 211
22 20 216 316 211
18 18 216 320 211
22 20 216 320 211
18 18 216 400 211
22 20 216 400 211
22 20 216 320 211
22 20 216 320 211
18 18 216 495 230
22 20 216 495 230
18 18 216 564 230
22 20 216 564 230
18 18 216 564 230
22 20 216 564 230
22 20 216 564 230
Bl
–
14
14
14
14
14
14
16
16
16
16
18
20
20
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
40
40
40
45
45
50
50
50
50
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
x(I)
–
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
155
155
155
155
155
155
155
155
192
192
192
192
192
192
192
192
212
212
212
212
212
212
212
280
280
280
280
280
280
280
280
280
280
280
280
315
315
315
315
315
315
315
x(I)* x(II) x(II)* z(I)
– – – –
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
192
145
192
145
192
145
192
145
192
145
192
145
192
145
192
145
212
165
212
165
212
165
212
165
212
165
212
165
212
165
212
165
280
207
280
207
280
207
280
207
280
207
280
207
280
207
315
242
315
242
315
242
315
242
315
242
315
242
315
242
315
242
315
242
315
242
315
242
315
242
296
296
296
296
296
296
296
z(I)* z(II) z(II)*
– – – –
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
165
4L
165
4L
165
4L
165
4L
165
4L
165
4L
165
4L
165
4L
207
4L
207
4L
207
4L
207
4L
207
4L
207
4L
207
4L
207
4L
242
4L
242
8L
242
8L
242
8L
242
8L
242
8L
242
8L
296
8L
296
8L
296
8L
296
8L
296
8L
296
8L
296
8L
296
8L
296
8L
296
8L
296
8L
296
8L
8L
8L
8L
8L
8L
8L
8L
Relubricating
facility possible
c
HA
7
7
10
10
11
11
12
12
14
14
15
11
18
18
18
16
16
16
16
16
16
18
18
18
18
20
20
20
20
22
22
22
25
25
25
25
28
28
32
32
32
32
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
r(I)* 3)
b2
–
119
119
119
119
137
137
165
165
165
165
213
213
213
213
213
-
r(I) 3)
b1
N
95
95
95
95
110
110
130
130
130
130
180
180
180
180
180
230
230
230
230
230
230
250
250
250
250
250
250
250
250
300
300
300
350
350
350
350
450
450
450
450
450
450
550
550
550
550
550
550
550
550
550
550
550
550
550
550
550
p(II)*B3
b
A
90
90
100
100
112
112
125
125
140
140
160
160
190
190
190
216
216
216
216
216
216
254
254
254
254
279
279
279
279
318
318
318
356
356
356
356
406
406
457
457
457
457
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
p(II)B3
a1
P
140
140
140
140
160
160
200
200
200
200
250
250
250
250
250
300
300
300
300
300
300
350
350
350
350
350
350
350
350
400
400
400
450
450
450
450
550
550
550
550
550
550
660
660
660
660
660
660
660
660
660
660
660
660
660
660
660
p*(I)B3
a
B
71
71
80
80
90
90
100
100
100
125
140
140
140
140
140
140
140
140
178
178
178
210
210
210
254
241
241
279
279
305
305
305
286
311
311
311
349
349
368
368
419
419
406
406
457
457
457
457
457
457
457
457
508
508
508
508
508
p(I)B3
56
56
63
63
71
71
80
80
90
90
100
100
112
112
112
132
132
132
132
132
132
160
160
160
160
180
180
180
180
200
200
200
225
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
–
Overall length
K2,4
G2,4
K2,4,6
G2,4,6
K2,4,6,8
G2,4,6,8
K2,4,6,8
G2,4,6,8
S2,4,6,8
L2,4,6,8
L2,4,6,8
LX4,8
M2,6,8
M4
MX2,4
S2
SX2
S4,6,8
M4
MX6
M6,8
M2,4,6,8
MX8
MX2
L2,4,6,8
M2
M4
L4
L6,8
L2,4,6,8
LX6
LX2
S4,8
M2
M4
M6,8
M2
M4,6,8
S2
S4,6,8
M2
M4,6,8
S2
S4,6,8
M2
M4,6,8
MX2
MX4
MX6,8
MX10,12
MY2
MY4,6,8
L2
L4,6,8
LX2
LX4
LX6,8
Tolerance h
–
Type
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
KPER
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
Tolerance d1
at this time, sizes 56 - 280 available (extension to all sizes prepared) for areas with inflammable dust
Zone 21 DIN EN 50281-1-1, with surface cooling, type of cooling IC 411, degree of protection IP 65
Tolerance d
Three-phase motors with squirrel-cage rotor, types KPER, K11Q... Ex II 2 D
non-sparking type of protection Ex nA II. acc. to IEC 79-15
with surface cooling, type of cooling IC 411, degree of protection IP 55
Tolerance b1
Three-phase motors with squirrel-cage rotor, types KPER, K11R...Ex nA II
Hole pattern
Dimensions
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
yes
yes
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Special equipment relubricating facility
Flat grease nipple with head diameter 10 mm,
Grease outlet opposite to flat grease nipple
Special equipment relubricating facility not available for K11R 132 S, SX2, M6, M8 and
K21R 160 M, MX8
Three eye-bolts only in case of type of construction IM V1 from K11R 180 M2, L4
45
Constructive selection data
Bearing arrangement
1)
2)
In case of vertical types of construction Q317 C3;
For K11Q bearing type …RS
Wave washer
felt ring
γ-type seal
50A
60A
60A
60A
65A
65A
70A
70A
80A
80A
80A
-
- 11,5x19
- 14,5x21
- 19,5x26
- 24,5x35
- 24,5x35
- 29,2x40
- 29,2x40
RB85
RB100
RB85
RB100
RB85
RB100
-
80
90
100
110
110
110
-
130
130
130
140
140
150
150
170
-
6201 2Z C3
6202 2Z C3
6204 2Z C3
6205 2Z C3
6205 2Z C3
6206 2Z C3
6206 2Z C3
6207 2RS C3
6308 2RS C3 2)
6308 2RS C3
6309 2RS C3 2)
6309 2RS C3
6310 C3 2)
6310 C3 2)
6312 C3 2)
6312 C3 2)
6312 C3 2)
6313 C3 2)
6313 C3 2)
6314 C3 2)
6314 C3
6316 C3 2)
6316 C3
6316 C3
6316 C3
6317 C3 1)
6317 C3 1)
6317 C3 1)
6317 C3 1)
felt ring
LX
M
S, SX2,M6,8
M4,MX6
M,MX8
MX2, L
M4, L6, 8
M2, L4
L, LX6
LX2
M2
S4, 8, M4,6,8,
M2
M4,6,8
S2,M2
S4,6,8,M4,6,8
S2,M2
S4,6,8,M4,6,8
MX2
MX4,6,8
MY2
MY4,6,8
L2, LX2
L4,6,8, LX4,6,8
6201 2Z C3
6202 2Z C3
6204 2Z C3
6205 2Z C3
6205 2Z C3
6206 2Z C3
6206 2Z C3
6208 2RS C3
6308 2RS C3 2)
6309 2RS C3
6310 2RS C3 2)
6310 2RS C3
6310 C3 2)
6312 C3 2)
6312 C3 2)
6312 C3 2)
6313 C3 2)
6313 C3 2)
6314 C3 2)
6314 C3 2)
NU 316 E
6316 C3 2)
NU 317 E
NU 317 E
NU 2220 E
NU 317 E
NU 320 E
NU 317 E
NU 320 E
fixed
bearing
Wave washer
63
71
80
90
100
100
112
132
132
160
160
180
180
200
200
225
225
250
250
280
280
315
315
315
315
315
315
315
315
N-side
Antifriction bearing
V-type seal
KPER
KPER
KPER
KPER
KPER
KPER
KPER
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
Antifriction bearing
V-type seal
D-side
Type
Disk spring
Basic design
50A
50A
60A
60A
60A
65A
65A
70A
70A
80A
80A
80A
80A
85A
85A
85A
85A
32
35
47
52
52
62
62
-
12x22
15x24
20x32
25x40
25x40
30x50
30x50
-
without
without
without
without
without
without
without
without
without
without
without
without
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
K21R 315 MX; MY; L; LX as standard with relubricating device
Special design „heavy bearing arrangement“
E
E
E
E
E
E
E
E
E
E
E
E
E
NU 316 E
40A
40A
45A
50A
50A
50A
60A
60A
RB60
RB65
RB65
RB70
RB70
basic version
RB80
basic version
basic version
basic version
basic version
basic version
basic version
basic version
6207 RS C3
6308 RS C3
6308 RS C3
6309 RS C3
6309 RS C3
6310 C3
6310 C3
6312 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
bearing arrangement
6316 C3
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
ab BG 225 for heavy bearing arrangement as standard with relubricating device
46
Disk spring
is heavy
is heavy
is heavy
is heavy
is heavy
is heavy
is heavy
is heavy
felt ring
208
308
309
310
310
310
312
312
312
313
313
314
314
fixed
bearing
Wave washer
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
Antifriction bearing
V-type seal
S, SX2,M6,8 VL
M4,MX6 VL
M, MX8 VL
MX2, L VL
M4, L6, 8 VL
M2, L4 VL
L, LX6 VL
LX2 VL
M2 VL
S4, 8, M4,6,8 VL
M2 VL
M4,6,8 VL
S2,M2 VL
S4,6,8,M4,6,8 VL
S2,M2 VL
S4,6,8,M4,6,8 VL
MX2 VL
MX4,6,8 VL
MY2 VL
MY4,6,8 VL
L2, LX2 VL
L4,6,8, LX4,6,8 VL
Wave washer
132
132
160
160
180
180
200
200
225
225
250
250
280
280
315
315
315
315
315
315
315
315
N-side
felt ring
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
γ-type seal
D-side
Antifriction bearing
V-type seal
Type
50A
50A
60A
60A
60A
65A
65A
70A
-
-
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
80A
-
-
N-side
Constructive selection data
Bearing arrangement
K11.
K11.
K11.
K11.
K11.
K11
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
132
132
160
160
180
180
200
200
225
225
250
250
280
280
315
315
315
315
315
315
315
315
S, SX2,M6,8
M4,MX6
M,MX8
MX2, L
*)
M4, L6, 8
*)
M2, L4
*)
L, LX6
*)
LX2
*)
M2
S4, 8, M4,6,8,
M2
M4,6,8
S2,M2
S4,6,8,M4,6,8
S2,M2
S4,6,8,M4,6,8
MX2
MX4,6,8
MY2
MY4,6,8
L2, LX2
L4,6,8, LX4,6,8
fixed
bearing
felt ring
Wave washer
Antifriction bearing
V-type seal
γ-type seal
N-side
Disk spring
D-side
Antifriction bearing
felt ring
Type
Wave washer
Relubricating device
at the D-side for reasons of design impossible
at the D-side for reasons of
110
110
110
RB60
RB65
RB65
RB70
RB70
RB80
RB80
RB80
see basic version
see basic version
see basic version
see basic version
see basic version
see basic version
6310 C3
6310 C3
6310 C3
6312 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
6314 C3
NU 316 E
6316 C3
NU 317 E
design impossible
6309 C3
6309 C3
6310 C3
130
6310 C3
130
6312 C3
130
6312 C3
140
6312 C3
140
6313 C3
150
6313 C3
150
6314 C3
6314 C3
170
6316 C3
6316 C3
60A
60A
65A
65A
70A
70A
80A
80A
-
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
-
*) degree of protection IP 54
Constructive selection data
Terminal box connection
Conventional design
Type
KPER
KPER
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
K11.
Terminal box
63 - 80
90 - 112
132
160 M6,8
160MX8
160 M2,4
160 MX2
160 L
180 M
180 L
200 L2,6,8
200 L4
200 LX2,6
225
250
280
315
Terminal plate according to DIN 46 295
Thread
of the
terminal stud
AlSi10Mg
GG25
GG 25
GG 25
GG 63
GG 63
GG 63
GG 63
GG 63
GG 63/100
GG100
GG100
GG100
GG200
GG200
GG200
KS
KS
KS
KS
KS
KS
KS
KS
KS
KS
KS
KS
KS
KS
KS
10
10
10
14
14
14
14
14
14
14
14
14
18
18
18
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
S 10x1
S 10x1
S 10x1
S 14x1,25
S 14x1,25
S 14x1,25
S 14x1,25
S 14x1,25
S 14x1,25
S 14x1,25
S 14x1,25
S 14x1,25
S 18x1,5
S 18x1,5
S 18x1,5
max.
design
current
Entry
16 A
M20x1,5-Ms
M25x1,5-Ms
M32x1,5-Ms
M32x1,5-Ms
M32x1,5-Ms
M40x1,5-Ms
M40x1,5-Ms
M40x1,5-Ms
M40x1,5-Ms
M40x1,5-Ms
M50x1,5-Ms
M50x1,5-Ms
M50x1,5-Ms
M50x1,5-Ms
M63x1,5-Ms
M63x1,5-Ms
M63x1,5-Ms
40 A
40 A
40 A
53 A
65 A
65 A
65 A
65 A
65 A
65 A
65 A
65 A
110 A
110 A
110 A
cable diameter range
7
9
11
11
19
19
19
19
19
19
27
27
27
27
34
34
34
-
13
17
21
21
21
28
28
28
28
28
35
35
35
35
45
45
45
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
47
Motor selection data
Design point 400 V, 50 cps, Ex II 3 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 22 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 55
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 3000 rpm - 2-pole design
K21R
K21R
56 K2
56 G2
0,09
0,12
2865
2830
69,0
69,0
0,75
0,78
0,25
0,32
4,9
4,5
0,00013
0,00013
4,4
4,5
K21R
K21R
63 K2
63 G2
0,18
0,25
2790
2800
65,0
67,0
0,78
0,73
0,51
0,74
4,1
4,2
0,00013
0,00015
4,9
5,2
K21R
K21R
71 K2
71 G2
0,37
0,55
2780
2775
70,0
74,0
0,81
0,81
0,94
1,32
4,4
4,9
0,00025
0,00032
6,7
7,6
K21R
K21R
80 K2
80 G2
0,75
1,1
2825
2835
77,0
77,0
0,82
0,81
1,72
2,55
5,9
6,0
0,00057
0,00072
10,7
11,5
K21R
K21R
90 S2
90 L2
1,5
2,2
2850
2850
80,0
81,0
0,81
0,86
3,35
4,55
7,0
7,5
0,00132
0,0017
16
19
K21R
100 L2
3,0
2865
83,0
0,85
6,15
7,0
0,00275
25
K21R
112 M2
4,0
2900
83,0
0,83
8,4
7,0
0,0045
32
K21R
K11R
132 S2T1)
132 SX2
5,5
7,5
2890
2900
86,0
87,0
0,84
0,86
11
15
7,5
6,5
0,0055
0,0110
40
57
K11R
K11R
K11R
160 M2
160 MX2
160 L2
11,0
15,0
18,5
2910
2930
2920
87,0
88,8
90,5
0,92
0,90
0,92
20
27
32
7,5
7,1
7,2
0,0258
0,0575
0,0675
81
118
134
K11R
180 M2
22
2935
91,8
0,92
37,5
6,8
0,1050
165
K11R
K11R
200 L2
200 Lx2
30
37
2940
2940
92,8
93,0
0,92
0,90
50,5
64
7,3
7,0
0,1280
0,1930
195
255
K11R
225 M2
45
2940
93,7
0,91
76
7,5
0,2200
290
K11R
250 M2
55
2955
93,7
0,91
93
7,5
0,3750
360
K11R
K11R
280 S2
280 M2
75
90
2970
2970
94,6
94,7
0,92
0,91
124
151
7,5
8,5
0,6500
0,6750
490
510
K11R
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
315
110
132
160
200
250
315
2975
2975
2975
2970
2973
2975
95,4
95,4
96,0
96,0
96,1
96,7
0,91
0,91
0,93
0,92
0,93
0,92
183
219
259
327
404
511
8,5
8,5
8,5
8,2
7,3
7,4
1,210
1,440
1,760
2,820
3,66
4,43
720
800
980
1170
1460
1630
1)
S2
M2
MX2
MY2
L2
LX2
also available as K11R 132 S2
48
Motor selection data
Design point 400 V, 50 cps, Ex II 3 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 22 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 55
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 1500 rpm - 4-pole design
K21R
K21R
56 K4
56 G4
0,06
0,09
1410
1375
59,0
60,0
0,61
0,70
0,24
0,31
3,1
3,2
0,00019
0,00019
4,3
4,4
K21R
K21R
63 K4
63 G4
0,12
0,18
1370
1360
56,0
58,0
0,70
0,69
0,44
0,65
3,2
3,3
0,00019
0,00024
4,8
5,2
K21R
K21R
71 K4
71 G4
0,25
0,37
1385
1370
64,0
66,0
0,72
0,76
0,78
1,06
3,6
3,8
0,00040
0,00050
6,8
7,8
K21R
K21R
80 K4
80 G4
0,55
0,75
1400
1400
69,0
72,0
0,72
0,72
1,60
2,10
4,1
4,6
0,00087
0,00107
10,6
11,7
K21R
K21R
90 S4
90 L4
1,10
1,50
1410
1400
76,0
77,0
0,80
0,83
2,62
3,40
5,5
5,5
0,00207
0,00260
15,5
18
K21R
K21R
100 L4
100 LX4
2,20
3,00
1420
1430
79,0
82,6
0,78
0,79
5,15
6,65
6,0
6,4
0,00400
0,00725
23,5
30
K21R
112 M4
4,00
1435
83,0
0,79
8,80
6,9
0,00900
37
K21R
K11R
132 S4T1)
132 M4
5,5
7,5
1425
1450
85,0
86,0
0,79
0,84
11,80
15
6,3
6,0
0,01100
0,0280
47
70
K11R
K11R
160 M4
160 L4
11,0
15,0
1450
1465
86,0
88,0
0,85
0,86
21,5
28,5
6,8
7,3
0,0350
0,0780
92
120
K11R
K11R
180 M4
180 L4
18,5
22
1460
1465
88,5
90,5
0,86
0,84
35
42
6,8
6,5
0,0900
0,1380
136
170
K11R
200 L4
30
1465
91,5
0,85
55,5
7,0
0,1680
200
K11R
K11R
225 S4
225 M4
37
45
1470
1470
92,5
93,0
0,86
0,86
67
81
7,0
7,0
0,2750
0,3130
270
300
K11R
250 M4
55
1475
93,5
0,86
98,5
7,0
0,5250
375
K11R
K11R
280 S4
280 M4
75
90
1480
1480
94,1
94,6
0,86
0,86
134
160
7,0
7,0
0,950
1,100
520
580
K11R
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
315
110
132
160
200
250
315
1485
1485
1480
1485
1485
1490
95,1
95,1
95,0
96,0
96,1
96,5
0,86
0,86
0,87
0,88
0,90
0,88
194
233
279
342
417
535
7,5
7,0
7,0
7,5
8,0
8,6
1,960
2,270
2,730
4,820
5,93
6,82
740
840
1000
1200
1450
1630
1)
S4
M4
MX4
MY4
L4
LX4
also available as K11R 132 S4
49
Motor selection data
Design point 400 V, 50 cps, Ex II 3 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 22 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 55
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 1000 rpm - 6-pole design
K21R
K21R
63 K6
63 G6
0,09
0,12
895
880
48,0
50,0
0,59
0,59
0,46
0,59
2,5
2,5
0,00024
0,00027
4,9
5,7
K21R
K21R
71 K6
71 G6
0,18
0,25
925
915
57,0
59,0
0,52
0,56
0,88
1,10
2,8
2,9
0,00045
0,00060
7,4
8,3
K21R
K21R
80 K6
80 G6
0,37
0,55
915
915
63,0
67,0
0,70
0,69
1,22
1,73
3,4
3,7
0,00130
0,00175
11
12,5
K21R
K21R
90 S6
90 L6
0,75
1,10
935
935
69,0
73,0
0,65
0,69
2,43
3,15
4,5
4,6
0,00325
0,00425
16
19
K21R
100 L6
1,50
945
76,0
0,73
3,90
4,6
0,00625
24
K21R
112 M6
2,20
950
78,0
0,76
5,35
5,3
0,01225
33,5
K11R
K11R
K11R
132 S6
132 M6
132 MX6
3,0
4,0
5,5
955
955
955
78,2
80,0
83,0
0,82
0,80
0,83
6,8
9
11,5
5,4
6,0
5,0
0,0180
0,0230
0,0430
46
53
70
K11R
K11R
160 M6
160 L6
7,5
11,0
960
965
85,0
85,2
0,82
0,86
15,5
21,5
5,5
5,0
0,0530
0,1130
86
114
K11R
180 L6
15,0
965
86,0
0,83
30,5
6,0
0,1450
136
K11R
K11R
200 L6
200 LX6
18,5
22
970
970
88,1
88,8
0,87
0,87
35,0
41
5,5
6,2
0,2280
0,2680
175
200
K11R
225 M6
30
973
90,4
0,89
54
6,5
0,4430
265
K11R
250 M6
37
975
91,0
0,89
66
6,5
0,8250
360
K11R
K11R
280 S6
280 M6
45
55
980
980
92,0
92,5
0,87
0,88
81
97,5
6,0
6,5
1,2800
1,4800
465
520
K11R
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
315
75
90
110
132
160
200
985
990
990
990
985
990
93,7
94,4
94,0
95,0
95,3
95,0
0,87
0,88
0,88
0,88
0,89
0,87
133
156
192
228
272
349
7,0
7,0
7,5
7,5
7,5
8,3
2,6300
3,3300
3,6000
6,0000
6,67
8,60
690
800
880
1050
1250
1460
50
S6
M6
MX6
MY6
L6
LX6
Motor selection data
Design point 400 V, 50 cps, Ex II 3 D
Three-phase motors with squirrel-cage rotor
with surface cooling, type of cooling IC 411, duty type S1, continuous duty
motors for the use in zone 22 acc. to EN 50281-1-1+2
insulation class F, degree of protection IP 55
version for design voltages range A according to IEC 34-1, 50 cps
max. surface temperature 125 °C
Type
P
n
η
cos ϕ
IA/I
-
I
400 V
A
kW
rpm
%
J
m
kgm2
kg
Synchronous speed 750 rpm - 8-pole design
K21R
K21R
71 K8
71 G8
0,09
0,12
675
670
43,0
44,0
0,54
0,54
0,56
0,73
2,1
2,3
0,00050
0,00060
6,6
8,1
K21R
K21R
80 K8
80 G8
0,18
0,25
690
695
55,0
56,0
0,61
0,58
0,78
1,12
2,8
3,0
0,00130
0,00175
10,5
12
K21R
K21R
90 S8
90 L8
0,37
0,55
700
695
59,0
63,0
0,57
0,62
1,6
2,04
3,0
3,2
0,00300
0,00375
15
18
K21R
K21R
100 L8
100 LX8
0,75
1,1
705
705
67,0
72,0
0,60
0,68
2,7
3,25
3,3
4,0
0,00625
0,00900
23
28
K21R
112 M8
1,5
705
75,0
0,71
4,1
4,4
0,01225
33,5
K11R
K11R
132 S8
132 M8
2,2
3,0
705
705
75,5
78,0
0,76
0,75
5,5
7,4
4,5
4,5
0,0180
0,0230
46
53
K11R
K11R
K11R
160 M8
160 MX8
160 L8
4,0
5,5
7,5
710
710
725
79,3
81,4
83,0
0,78
0,78
0,78
9,3
12,5
16,5
4,0
4,5
4,5
0,0430
0,0530
0,1130
70
86
114
K11R
180 L8
11,0
720
85,0
0,78
24
4,5
0,1450
136
K11R
200 L8
15,0
725
86,5
0,79
31,5
5,0
0,2280
175
K11R
K11R
225 S8
225 M8
18,5
22
725
725
89,2
89,2
0,83
0,84
36
42,5
5,5
5,0
0,4400
0,4400
265
265
K11R
250 M8
30
730
90,2
0,79
61
5,5
0,8250
360
K11R
K11R
280 S8
280 M8
37
45
735
735
91,0
91,5
0,80
0,77
73,5
92
5,5
6,0
1,350
1,550
465
520
K11R
K11R
K11R
K11R
K11R
K11R
315
315
315
315
315
315
55
75
90
110
132
160
740
740
740
740
740
740
93,1
93,3
93,5
94,6
95,0
95,2
0,80
0,81
0,81
0,81
0,83
0,79
107
143
172
207
242
307
6,5
6,0
6,0
6,5
6,3
7,2
2,630
3,330
3,60
6,00
6,76
8,71
690
800
880
1050
1250
1430
S8
M8
MX8
MY8
L8
LX8
51
Constructive selection data
Dimensions
Three-phase motors with squirrel-cage rotor, types K21R, K11R... Ex II 3 D
The dimensions of the series K21R and K11R are
identical!
Tolerance for counter parts H7
2nd shaft end only for direct coupling
Bl = minimum distance for air inlet
= air inlet
→
52
–
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
d1
DA
9
11
11
14
14
19
19
22
22
24
28
28
28
28
32
32
32
38
38
32
38
38
42
42
48
42
48
42
48
48
55
55
55
55
55
55
55
65
65
65
65
65
70
65
70
65
70
70
70
65
70
65
70
65
70
70
–
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
k6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
m6
e
BB
86
86
100
100
116
116
125
125
130
155
175
171
180
180
180
180
180
180
218
218
218
257
257
257
301
288
288
326
326
360
360
360
343
368
368
368
412
412
431
431
482
482
503
503
554
554
554
554
554
554
573
573
624
624
624
624
624
e1
M
115
115
115
115
130
130
165
165
165
165
215
215
215
215
265
265
265
265
265
265
265
300
300
300
300
300
300
300
300
350
350
350
400
400
400
400
500
500
500
500
500
500
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
f
AB
110
110
128
128
138
138
168
168
178
178
192
188
224
224
256
256
256
256
256
256
256
296
296
296
296
328
328
328
328
372
372
372
413
413
413
413
471
471
522
522
522
522
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
f1
T
3
3
3
3
3,5
3,5
3,5
3,5
3,5
3,5
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
g
AC
109
109
109
109
124
124
139
139
157
157
177
196
196
196
196
217
217
217
258
258
217
258
258
313
313
351
313
351
313
351
351
390
390
390
390
390
440
440
490
490
490
490
550
550
550
550
550
550
550
550
610
610
610
610
610
610
610
g1 g1*
– –
178
178
178
200
200
178
200
200
242
242
261
242
261
242
261
261
300
300
300
300
300
326
326
388
388
388
388
420
420
420
420
420
420
420
420
487
487
487
487
487
487
487
218
218
218
240
240
218
240
240
288
288
307
288
307
288
307
307
358
358
358
358
358
384
384
426
426
426
426
465
465
465
465
465
465
465
465
h
H
56
56
63
63
71
71
80
80
90
90
100
100
112
112
132
132
132
132
132
132
132
160
160
160
160
180
180
180
180
200
200
200
225
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
Threaded center bores in the shaft end DIN 332-DS:
at diameter 11 up to 13 M4
at diameter 14 up to 16 M5
at diameter 17 up to 21 M6
at diameter 22 up to 24 M8
at diameter 25 up to 30 M10
–
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
-1,0
at
at
at
at
at
k k1 l
L LC E
173 - 20
179 219 20
179 205 23
179 205 23
206 238,5 30
206 238,5 30
249 293 40
249 293 40
276 330 50
298 352 50
332 386 60
359 425 60
359 425 60
393 459 60
430 498 80
459 542 80
479 562 80
459 542 80
481 565 80
481 565 80
479 562 80
559 643 110
559 643 110
571 686 110
609 724 110
635 751 110
609 724 110
680 796 110
609 724 110
680 796 110
680 796 110
727 851 110
757 881 140
767 891 110
797 921 140
757 881 140
862 977 140
862 977 140
924 1072 140
924 1072 140
970 1118 140
970 1118 140
1065 1218 140
1095 1248 170
1120 1273 140
1150 1303 170
1200 1353 140
1230 1383 170
1150 1303 170
1150 1303 170
1270 1448 140
1300 1478 170
1390 1568 140
1420 1598 170
1510 1688 140
1540 1718 170
1420 1598 170
diameter
diameter
diameter
diameter
diameter
l1
EA
20
23
23
30
30
40
40
50
50
60
60
60
60
60
80
80
80
80
80
80
80
80
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
m m1 n o
BA
AA –
18
18
28
28
32
32
38
38
40
40
45
33 123,5
50 123,5
50 157,5
50 155
55
50 168
55
50 188
55
50 168
55
50 173
55
50 173
55
50 188
60
55 221
60
55 221
60
55 211
60
55 249
65
62 239
65
62 249
65
62 284
65
62 249
70
70 284
70
70 284
70
70 292
75
75 292
75
75 332
75
75 332
75
75 292
84
84 382
84
84 382
96
94 383
96
94 383
96
94 429
96
94 429
120
126 519
120
126 519
120
126 574
120
126 574
120
126 654
120
126 654
120
126 574
120
126 574
120
110 630
120
110 630
120
110 645
120
110 645
120
110 765
120
110 765
120
110 645
31 up to 38
39 up to 50
51 up to 90
51 up to 90
100 M24
M12
M16
M20
M21
HD
154
154
161
161
175
175
191
191
210
210
227
237
249
249
269
310
310
310
332
332
310
377
377
402
402
441
422
441
422
461
461
500
525
525
525
525
622
622
668
668
668
668
735
735
735
735
735
735
735
735
802
802
802
802
802
802
802
–
–
–
350
350
350
372
372
350
448
448
487
468
487
468
507
507
558
583
583
583
583
716
716
716
716
790
790
790
790
790
790
790
790
628
628
628
628
695
695
695
695
695
695
695
695
835
835
835
835
835
835
835
728
728
728
728
795
795
795
795
795
795
795
795
p(I) p(I)* p(II) p(II)* q
HD – HD – –
328
328
328
350
350
328
392
392
417
417
436
417
436
417
461
461
500
525
525
525
525
647
647
663
663
663
663
750
750
750
750
750
750
750
750
827
827
827
827
827
827
827
368
368
368
390
390
368
563
563
482
463
482
463
507
507
558
583
583
583
583
701
701
701
701
805
805
805
805
805
805
805
805
628
628
628
628
710
710
710
710
710
710
710
710
850
850
850
850
850
850
850
–
M20
M20
M20
M20
M20
M20
M25
M25
M25
M25
M25
235,5 M25
235,5 M25
235,5 M25
275 M25
291 M32
291 M32
291 M32
308 M32
308 M32
291 M32
338 M40
338 M40
360 M40
360 M40
396 M40
360 M40
396 M40
360 M40
396 M50
396 M50
435 M50
465 M50
435 M50
465 M50
465 M50
480 M63
480 M63
728 541 M63
728 541 M63
728 541 M63
728 541 M63
810 546 M63
810 576 M63
810 546 M63
810 576 M63
810 546 M63
810 576 M63
810 576 M63
810 576 M63
640 M63
670 M63
745 M63
775 M63
745 60
775 60
775 60
r(II) r(II)*
–
M40
M40
M40
M40
M40
M40
M50
M50
M50
M50
M50
M50
M50
M50
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
M63
64
64
64
64
64
64
64
64
64
64
64
64
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
-
* Design with larger terminal box
** Design with VIK terminal box with entry bush
I Terminal box for threaded joint
2) Conduit according to cable diameter max. 83 mm
3) Thread lead … x 1,5
s
K
6
6
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
19
19
19
19
19
19
19
24
24
24
24
24
24
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
s1
S
9
9
9
9
9
9
11
11
11
11
14
14
14
14
14
14
14
14
14
14
14
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
t
GA
10
10
13
13
16
16
22
22
27
27
31
31
31
31
41
41
41
41
41
41
41
45
45
45
45
51,5
51,5
51,5
51,5
59
59
59
64
59
64
64
64
69
69
79,5
69
79,5
69
85
69
85
69
85
85
85
69
85
69
85
69
85
85
t1
GC
10
13
13
16
16
22
22
25
25
27
31
31
31
31
35
35
35
41
41
35
41
41
45
45
51,5
45
51,5
45
51,5
51,5
59
59
59
59
59
59
59
69
69
69
69
69
74,5
69
74,5
69
74,5
74,5
74,5
69
74,5
69
74,5
69
74,5
74,5
u u1 w1 w2 A
F FA C CA –
3
- 36 - 57
3
3 36 52 57
4
4 40 39 57,5
4
4 40 39 57,5
5
5 45 43,5 61
5
5 45 43,5 61
6
6 50 63 67
6
6 50 63 67
8
6 56 74 70
8
6 56 71 70
8
8 63 73 75
8
8 63 102 77
8
8 70 95 77
8
8 70 129 77
10 8 89 121 77
10 10 89 153 108
10 10 89 173 108
10 10 89 153 108
10 10 89 138 114
10 10 89 138 114
10 10 89 135 108
12 10 108 135 135
12 10 108 135 135
12 12 108 148 138
12 12 108 142 138
14 14 121 169 147
14 12 121 142 138
14 14 121 176 147
14 12 121 104 138
16 14 133 138 147
16 14 133 138 147
16 16 133 193 168
18 16 149 196 168
16 16 149 211 168
18 16 149 211 168
18 16 149 171 168
18 16 168 210 177
18 16 168 210 177
18 18 190 234 206
20 18 190 234 206
18 18 190 229 206
20 18 190 229 206
18 18 216 316 211
22 20 216 316 211
18 18 216 320 211
22 20 216 320 211
18 18 216 400 211
22 20 216 400 211
22 20 216 320 211
22 20 216 320 211
18 18 216 495 230
22 20 216 495 230
18 18 216 564 230
22 20 216 564 230
18 18 216 564 230
22 20 216 564 230
22 20 216 564 230
Bl
–
14
14
14
14
14
14
16
16
16
16
18
20
20
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
40
40
40
45
45
50
50
50
50
55
55
55
55
55
55
55
55
55
55
55
55
55
55
55
x(I) x(I)* x(II)
– – –
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
155 192
155 192
155 192
155 192
155 192
155 192
192
192
192 212
192 212
192 212
192 212
192 212
192 212
212 212
212 212
212 280
212 280
212 280
212 280
212 280
280
280
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
280 315 387
315 430**) 422
315 430**) 422
315 430**) 422
315 430**) 422
315 430**) 422
315 430**) 422
315 430**) 422
x(II)* z(I) z(I)* z(II)
– – – –
92
92
92
92
92
92
92
92
92
92
92
92
92
92
92
145 165
145 165
145 165
145 165
145 165
145 165
165
165
165 207
165 207
165 207
165 207
165 207
165 207
207 207
207 207
207 242
207 242
207 242
207 242
207 242
242
242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
422 242 296 242
- 296 350**) 296
- 296 350**) 296
- 296 350**) 296
- 296 350**) 296
- 296 350**) 296
- 296 350**) 296
- 296 350**) 296
z(II)*
– –
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
4L
8L
8L
8L
8L
8L
8L
296 8L
296 8L
296 8L
296 8L
296 8L
296 8L
296 8L
296 8L
296 8L
296 8L
296 8L
296 8L
- 8L
- 8L
- 8L
- 8L
- 8L
- 8L
- 8L
Relubricating
facility possible
d
D
9
9
11
11
14
14
19
19
24
24
28
28
28
28
38
38
38
38
38
38
38
42
42
42
42
48
48
48
48
55
55
55
60
55
60
60
60
65
65
75
65
75
65
80
65
80
65
80
80
80
65
80
65
80
65
80
80
Hole pattern
c1
LA
9
9
9
9
9
9
10
10
10
10
11
11
11
11
12
12
12
12
12
12
12
13
13
13
13
13
13
13
13
15
15
15
16
16
16
16
18
18
18
18
18
18
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
r(I)* 3)
c
HA
7
7
10
10
11
11
12
12
14
14
15
11
18
18
18
16
16
16
16
16
16
18
18
18
18
20
20
20
20
22
22
22
25
25
25
25
28
28
32
32
32
32
44
44
44
44
44
44
44
44
44
44
44
44
44
44
44
r(I) 3)
b2
–
119
119
119
119
137
137
165
165
165
165
213
213
213
213
-
p(II)*B3
–
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
j6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
h6
p(II)B3
b1
N
95
95
95
95
110
110
130
130
130
130
180
180
180
180
230
230
230
230
230
230
230
250
250
250
250
250
250
250
250
300
300
300
350
350
350
350
450
450
450
450
450
450
550
550
550
550
550
550
550
550
550
550
550
550
550
550
550
p*(I)B3
b
A
90
90
100
100
112
112
125
125
140
140
160
160
190
190
216
216
216
216
216
216
216
254
254
254
254
279
279
279
279
318
318
318
356
356
356
356
406
406
457
457
457
457
508
508
508
508
508
508
508
508
508
508
508
508
508
508
508
Tolerance h
a1
P
140
140
140
140
160
160
200
200
200
200
250
250
250
250
300
300
300
300
300
300
300
350
350
350
350
350
350
350
350
400
400
400
450
450
450
450
550
550
550
550
550
550
660
660
660
660
660
660
660
660
660
660
660
660
660
660
660
Tolerance d1
a
B
71
71
80
80
90
90
100
100
100
125
140
140
140
140
140
140
140
140
178
178
178
210
210
210
254
241
241
279
279
305
305
305
286
311
311
311
349
349
368
368
419
419
406
406
457
457
457
457
457
457
457
457
508
508
508
508
508
p(I)B3
56
56
63
63
71
71
80
80
90
90
100
100
112
112
132
132
132
132
132
132
132
160
160
160
160
180
180
180
180
200
200
200
225
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
–
Overall length
K2,4
G2,4
K2,4,6
G2,4,6
K2,4,6,8
G2,4,6,8
K2,4,6,8
G2,4,6,8
S2,4,6,8
L2,4,6,8
L2,4,6,8
LX4,8
M2,6,8
M4
S2,4T
S2
SX2
S4,6,8
M4
MX6
M6,8
M2,4,6,8
MX8
MX2
L2,4,6,8
M2
M4
L4
L6,8
L2,4,6,8
LX6
LX2
S4,8
M2
M4
M6,8
M2
M4,6,8
S2
S4,6,8
M2
M4,6,8
S2
S4,6,8
M2
M4,6,8
MX2
MX4
MX6,8
MX10,12
MY2
MY4,6,8
L2
L4,6,8
LX2
LX4
LX6,8
Tolerance d
–
Type
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
Tolerance b1
for zones with flammable dust zone 22 DIN EN 50281-1-1
with surface cooling, type of cooling IC 411, degree of protection IP 55
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
no
yes
yes
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Special equipment relubricating facility
Flat grease nipple with head diameter 10 mm,
Grease outlet opposite to flat grease nipple
Special equipment relubricating facility not available for K11R 132 S, SX2, M6, M8 and
K11R 160 M, MX8
Three eye-bolts only in case of type of construction IM V1 from K11R 180 M2, L4
53
Constructive selection data
Dimensions
Figures
Constructive selection data
Bearing arrangement
Basic design
1)
In case of vertical types of construction Q317 C3;
Wave washer
80
90
100
110
110
110
-
felt ring
- 11,5x19
- 14,5x21
- 19,5x26
- 24,5x35
- 24,5x35
- 29,2x40
- 29,2x40
RB85
RB100
RB85
RB100
RB85
RB100
-
Wave washer
LX
M
S, SX2,M6,8
M4,MX6
M,MX8
MX2, L
M4, L6, 8
M2, L4
L, LX6
LX2
M2
S4, 8, M4,6,8,
M2
M4,6,8
S2,M2
S4,6,8,M4,6,8
S2,M2
S4,6,8,M4,6,8
MX2
MX4,6,8
MY2
MY4,6,8
L2, LX2
L4,6,8, LX4,6,8
felt ring
50A
60A
60A
60A
65A
65A
70A
70A
80A
80A
80A
-
γ-type seal
6201 2Z C3
6202 2Z C3
6204 2Z C3
6205 2Z C3
6205 2Z C3
6206 2Z C3
6206 2Z C3
6208 2RS C3
6308 2RS C3
6309 2RS C3
6310 2RS C3
6310 2RS C3
6310 C3
6312 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
6314 C3
NU 316 E
6316 C3
NU 317 E
NU 317 E
NU 2220 E
NU 317 E
NU 320 E
NU 317 E
NU 320 E
fixed
bearing
Antifriction bearing
V-type seal
63
71
80
90
100
100
112
132
132
160
160
180
180
200
200
225
225
250
250
280
280
315
315
315
315
315
315
315
315
N-side
Disk spring
K21R
K21R
K21R
K21R
K21R
K21R
K21R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
D-side
Antifriction bearing
V-type seal
Type
-
6201 2Z C3
6202 2Z C3
6204 2Z C3
6205 2Z C3
6205 2Z C3
6206 2Z C3
6206 2Z C3
6207 2RS C3
6308 2RS C3
6308 2RS C3
6309 2Rs C3
6309 2RS C3
6310 C3
6310 C3
6312 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
6314 C3
6316 C3
6316 C3
6316 C3
6316 C3
6317 C3 1)
6317 C3 1)
6317 C3 1)
6317 C3 1)
50A
50A
60A
60A
60A
65A
65A
70A
70A
80A
80A
80A
80A
85A
85A
85A
85A
32
35
47
52
52
62
62
-
12x22
15x24
20x32
25x40
25x40
30x50
30x50
-
130
130
130
140
140
150
150
170
-
without
without
without
without
without
without
without
without
without
without
without
without
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
K11R 315 MX ; MY ; L ; LX as standard with relubricating device
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
NU
208
308
309
310
310
310
312
312
312
313
313
314
314
E
E
E
E
E
E
E
E
E
E
E
E
E
NU 316 E
40A
40A
45A
50A
50A
50A
60A
60A
RB60
RB65
RB65
RB70
RB70
basic version
RB80
basic version
basic version
basic version
basic version
basic version
basic version
basic version
6207 RS C3
6308 RS C3
6308 RS C3
6309 RS C3
6309 RS C3
6310 C3
6310 C3
6312 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
bearing arrangement
6316 C3
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
bearing arrangement
from size BG 225 for heavy bearing arrangement as standard with relubricating device
54
Disk spring
felt ring
is heavy
is heavy
is heavy
is heavy
is heavy
is heavy
is heavy
is heavy
felt ring
S, SX2,M6,8 VL
M4,MX6 VL
M, MX8 VL
MX2, L VL
M4, L6, 8 VL
M2, L4 VL
L, LX6 VL
LX2 VL
M2 VL
S4, 8, M4,6,8 VL
M2 VL
M4,6,8 VL
S2,M2 VL
S4,6,8,M4,6,8 VL
S2,M2 VL
S4,6,8,M4,6,8 VL
MX2 VL
MX4,6,8 VL
MY2 VL
MY4,6,8 VL
L2, LX2 VL
L4,6,8, LX4,6,8 VL
fixed
bearing
Wave washer
132
132
160
160
180
180
200
200
225
225
250
250
280
280
315
315
315
315
315
315
315
315
N-side
Antifriction bearing
V-type seal
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
γ-type seal
D-side
Antifriction bearing
V-type seal
Type
Wave washer
Special design „heavy bearing arrangement“
50A
50A
60A
60A
60A
65A
65A
70A
-
-
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
80A
-
-
N-side
Constructive selection data
Bearing arrangement
Relubricating device
felt ring
γ-type
rotary seal
at the D-side for reasons of
at the D-side for reasons of
at the D-side for reasons of
110
110
110
RB60
RB65
RB65
RB70
RB70
RB80
RB80
RB80
see basic version
see basic version
see basic version
see basic version
see basic version
see basic version
6310 C3
6310 C3
6310 C3
6312 C3
6312 C3
6312 C3
6313 C3
6313 C3
6314 C3
6314 C3
NU 316 E
6316 C3
NU 317 E
design impossible
design impossible
design impossible
6309 C3
6309 C3
6310 C3
130
6310 C3
130
6312 C3
130
6312 C3
140
6312 C3
140
6313 C3
150
6313 C3
150
6314 C3
6314 C3
170
6316 C3
6316 C3
felt ring
S, SX2,M6,8
M4,MX6
M,MX8
MX2, L
*)
M4, L6, 8
*)
M2, L4
*)
L, LX6
*)
LX2
*)
M2
S4, 8, M4,6,8,
M2
M4,6,8
S2,M2
S4,6,8,M4,6,8
S2,M2
S4,6,8,M4,6,8
MX2
MX4,6,8
MY2
MY4,6,8
L2, LX2
L4,6,8, LX4,6,8
fixed
bearing
Wave washer
132
132
160
160
180
180
200
200
225
225
250
250
280
280
315
315
315
315
315
315
315
315
Antifriction bearing
V-type
rotary seal
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K21R
N-side
Disk spring
D-side
Antifriction bearing
Wave washer
Type
45A
45A
50A
50A
60A
60A
60A
65A
65A
70A
70A
80A
80A
-
-
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
N-side
*) degree of protection IP 54
Constructive selection data
Terminal box connection
Basic design
Type
K21R
K21R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
K11R
1)
2)
Terminal box
63 - 80
90 - 112
132
160 M2 - 8, MX8
160 L, MX2
180
200 L, LX6
200 LX2
225
250
280
315S, M
315MX
315S, M
315MX
315MY, L, LX
Material
Standard
as option
16A
AlSi10 Mg
GG
25A
25A/63A
63A
63A
63A/100A
100A
100A
100A/200A
200A
200A
200A
400A 1)
400A 1)
400A 2)
AlSi10 Mg
AlSi10 Mg
AlSi10 Mg
AlSi10 Mg
AlSi10 Mg
Bl / GG
Bl / GG
Bl / GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
GG
Terminal plate
Thread of the
terminal stud
Thread
Protective
conductor
K1M4 DIN 46294 / M4
M4
SB5
SB5
SB6
SB6
SB6
SB8
SB8
SB8
SB10
SB10
SB10
SB12
SB12
SB12
/
/
/
/
/
/
/
/
/
/
/
/
/
/
M5
M5
M6
M6
M6
M8
M8
M8
M10
M10
M10
M12
M12
M12
M6
M6
M6
M6
M6
M8
M8
M8
M10
M10
M10
M10
M10
M10
Entry
M20x1,5
M25x1,5
M32x1,5
M40x1,5
M40x1,5
M40x1,5
M50x1,5
M50x1,5
M50x1,5
M63x1,5
M63x1,5
M63x1,5
M63x1,5
M63x1,5
M63x1,5
M63x1,5
Cable diameter range
7
9
11
19
19
19
27
27
27
34
34
34
34
34
34
34
-
13
17
21
28
28
28
35
35
35
45
45
45
45
45
45
45
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
Version 220/380 V ∆/Y resp. 230/400 V ∆/Y
Version 220/380 V ∆/Y resp. 230/400 V ∆/Y not available
55
VEM / 04-042 E / 10.00 HDW Printed in the Federal Republik of Germany. Änderungen vorbehalten.
We get things moving
VEM motors GmbH
VEM motors GmbH
Carl-Friedrich-Gauß-Str. 1
38855 Wernigerode
Postfach-Nr. 10 12 52
38842 Wernigerode
Telefon 0 39 43 / 68 0

Similar documents

Frame size 63-45055 II 2 G EExd(e) IIC(B) T455

Frame size 63-45055 II 2 G EExd(e) IIC(B) T455 Three-phase low-voltage squirrel-cage motors, IP55 II 2 G EExd(e) IIC(B) T4 Flameproof enclosure “d“ Shaft centre heights 63-450 ■ Single speed motors ■ Change pole motors ■ Motors for frequency co...

More information

single phase induction motor

single phase induction motor Guide for testing three phase induction motors

More information